National Thermal Power Corporation Limited - Bihar

43351587 bids are invited for custom bid for services 200131813 biennial contract for mechanical maintenance of chp system equipment ntpc kanti, 10.10. ( fhcpl00bd800 ) coupling ( <> ) replacement coupling replacement. for measurement purpose any one of the following will be treated as one unit. replacement of fluid coupling ‘or’ conveyor drive brake drum ‘or’ gear box cooling fan or flexible coupling a ) shifting of new / repaired fluid coupling / brake drum / cooling fan / flexible coupling at site. b ) decoupling of fluid coupling / dismantling of thruster brakes ( if required ) and shifting of motor to the required place. c ) removal of fluid coupling / brake drum / cooling fan / flexible coupling from motor / gear box. d ) mounting of new / repaired fluid coupling / brake drum / cooling fan / flexible coupling, placement of motor and oil filling in coupling if required. e ) coupling of the drive and system normalization after the alignment. f ) trial run and defect rectification, if any fluid coupling dis mounted after dismantling then assembling of coupling after defective part replacement is in the scope of the contractor without any extra claim. g ) shifting of old fluid coupling / brake drum / cooling fan at chp workshop or as per direction of engr in charge. h ) if brake drum, cooling fan and flexible coupling replaced at a time, no extra payment will be made. it will also be applicable for removal & remounting of couplings. i ) cutting / welding required for the job comes under contractor’s scope. 10.20 ) . ( fhiid00bd800 ) impact idlers ( <> ) repl. idlers repl. / screw take up tightening and loosening / idler frame repl. / scrapper repl. / deck plate repl. replacement of rollers / idlers: [ for payment purpose replacement of total no. of rollers / idlers in one frame carrying / return will be treated as one unit. ] a ) replacement of any rollers / idlers in chp comes under this. b ) shifting of new / repaired rollers / idlers at site and fixing at required place. c ) shifting of old / damaged rollers / idlers to chp workshop / chp scrap yard. d ) if more than one rollers / idlers are replaced in same frame simultaneously, it will be treated as one unit. ‘or’ for measurement purpose any one of the following will be treated as one unit. screw take up loosening and tightening: a ) it includes all screw take ups in chp conveyors. b ) loosening of screw take up as per requirement and retightening it as per direction. or replacement of idler frame: a ) replacement of any idler frame in chp comes under this. b ) shifting of new / repaired idler frame at site and fixing at required place. c ) shifting of old / damaged idler frame to chp workshop / chp scrap yard. d ) if idlers are also replaced during frame replacement, no extra payment will be made. e ) cutting / welding required for the job comes under contractor’s scope. ‘or‘ scrapper replacement: a ) removal of worn out rubber, making new rubber from old conveyor belt / rubber sheet, as per requirement. b ) fixing of rubber in scraper and reinstallation on the conveyor. c ) cutting / welding required for the job comes under contractor’s scope. ‘or‘ replacement of deck plate ( 01. no ) : a ) removal of existing plate after removing the idlers & frames as required. b ) shifting of new deck plate ( including wooden one ) at site & fixing it. c ) normalization of the system. d ) cutting / welding required for the job comes under contractor’s scope. 10.30 ) . ( fhg / b58bd800 ) gear boxes ( hold back ) repl ( 6 hrs ) gear box hold back replacement / fluid coupling oil replacement / decoupling and coupling of gear coupling / thruster replacement / thruster overhauling gear box hold back replacement: a ) replacement of hold back of any conveyor gear box in chp comes under this. b ) shifting of new / repaired hold back from chp store / central store / central workshop to site. c ) removal of old hold back from gear box and fixing of new hold back. d ) trial run and defect rectification, if any. e ) shifting of old hold back to chp workshop. for payment purpose one g box hold back repl. will be treated as one unit. ‘or’ fluid coupling oil replacement: a ) oil replacement of any fluid coupling in chp comes under this. b ) removal of coupling guard, opening of fusible plug / filling plug and draining of oil in a can & shifting it to chp scrap yard. c ) shifting of oil at site & filling in the fluid coupling up to specified angle. d ) fitting the fusible plug / filling plug, fixing of coupling guard. for payment purpose two fluid coupling oil replacements will be treated as one unit. ‘or‘ decoupling and coupling of gear coupling ( after greasing ) : a ) this covers all gear couplings being used in chp. for payment purpose decoupling and coupling of gear coupling of one gear coupling will be treated as one unit. ‘or thruster replacement: a ) replacement of any thruster ( except stacker rail clamp ) in chp comes under this. b ) shifting of new / repaired thruster at site. c ) removal old thruster and fixing of new one, stroke adjustment as per requirement. d ) shifting of old thruster to chp workshop. e ) trial run and defect rectification if any for payment purpose one thruster repl. will be treated as one unit. ‘or’ thruster overhauling: a ) this covers for any thruster being used in chp b ) dismantling of thruster as per direction of area engr. c ) replacement of damaged part as per direction & reassembling. d ) oil filling and testing for smooth operation. for payment purpose one thruster overhauling will be treated as one unit. 10.40 ) . ( fhp / c12bd800 ) pulley / coupling ( nde brg ) repl servicing of fluid coupling / replacement of conveyor non drive end bearing / plumber block for measurement purpose any one of them will be treated as separate unit. servicing of fluid coupling: a ) this covers any fluid coupling being used in chp. b ) dismantling of fluid coupling as per direction. c ) replacement of defective parts of fluid coupling as per direction and re assembling. d ) testing of oil leakage by filling oil. defect rectification, if any. ‘or’ replacement of conveyor non drive end bearing / plumber block: a ) it includes any bearing / plumber block of any pulley including gtu / bend / snub / drive pulley of any conveyor in chp. b ) belt clamping, take up lifting & lowering will be in the scope of this contract. c ) shifting of new bearing / plumber block at site. d ) opening and removal of plumber block / bearing form the pulley. e ) mounting of new bearing on the pulley and fixing of plumber block and greasing bearings. f ) if required bearing of non drive pulley will also be replaced. g ) system normalization. trial run and defect rectification, if any. h ) if plumber block is replaced at the time of bearing replacement, no extra payment will be made. 10.50 ) . ( fhcht51bd800 ) chutes ( skirt rubber ) repl skirt rubber replacement / shifting of oil / lubricant drums skirt rubber replacement: a ) replacement of rubber of any skirt comes under this, if skirt is damaged. b ) opening of skirt rubber clamp and removing of worn out rubber. c ) making the new skirt rubber, from old conveyor belt / skirt rubber sheet, as per requirement. d ) fixing of new rubber in frame & mounting it on the skirt and trial run for leakage arresting. e ) for measurement purpose, for measurement purpose one metre or part will be taken as one unit. ‘or’ shifting of oil / lubricant drums from central stores or any other place inside plant to chp store and vice versa: a ) it includes shifting of filled oil / grease drums from central stores or any other place inside plant to chp store and vice versa. b ) shifting of one drum will be taken as one unit. c ) transportation arrangement is to be arranged by the contractor. 10.60 ) . fhp / c52bd800: conv pulleys ( <> ) ( non drive ) repl conv pulleys ( non drive ) repl / replacement of take up pulley / replacement of conveyor pulley bearing / plumber block ( drive end ) / gear coupling replacement ( one pair ) a ) replacement of all non drive pulley including snub pulley, bend pulley, tail pulley and tail snub pulley comes under this. b ) shifting of new / repaired pulley from chp store / central store / central workshop to site. c ) belt clamping, take up lifting and lowering will be in the scope of this contract. d ) removal old pulley, bearings and plumber block from the old pulley. e ) mounting of bearings and plumber blocks, on the new pulley. f ) placement of new pulley on position and alignment with the system. g ) system normalization trial run and defect rectification, if any. h ) shifting of old pulley to chp workshop / central workshop. ‘or’ replacement of take up pulley: a ) replacement of take up pulley of any conveyor comes under this. b ) shifting of new repaired pulley at site. c ) belt clamping, take up lifting and lowering will be in the scope of this contract. d ) cutting the conveyor belt at the required place if required and removal of old pulley from foundation. e ) removal of bearings / plumber blocks of pulley. f ) mounting of bearings and plumber blocks on the new pulley. g ) lifting of new pulley and mounting it on the foundation. h ) pulling of conveyor belt and belt joint will not be in the scope of this contract. i ) system normalization, trial run & defect rectification, if any. j ) shifting of old / damaged pulley to chp / central workshop. ‘or’ replacement of conveyor pulley bearing / plumber block ( drive end ) : a ) decoupling of gear box and shifting it to the required place. b ) removal of low speed side coupling half. c ) belt clamping, take up lifting and lowering will be in the scope of this contract. d ) drive pulley lifting and removal of plumber block / bearings. e ) shifting of new bearing / plumber block and mounting it on the pulley. greasing of bearing. f ) system normalization, placement of gear box and alignment. g ) trial run and defect rectification, if any. h ) if plumber block is replaced at the time of bearing replacement, no extra payment will be made. ‘or’ gear coupling replacement ( one pair ) : a ) replacement of any gear coupling of any conveyor belt comes under this. b ) shifting of new / repaired gear coupling at site. c ) removal of coupling guards, decoupling of gear box from both high speed side and slow speed side. shifting of motor and gear box at required place and removal of gear coupling after dismantling of thruster brake, if required. d ) mounting of new gear coupling, placement of gear box at foundation. e ) normalization of system after alignment, for alignment. f ) trial run and defect rectification, if any. g ) shifting of old gear coupling to chp workshop. h ) cutting / welding required for the job comes under contractor’s scope. 10.70 ) . ( fhcnp00bd800 ) conv pulleys ( <> ) repl replacement of drive pulley: a ) replacement of drive pulley of any conveyor in chp ( except coal / sampler ) comes under this. b ) shifting of new / repaired pulley from central store / chp store / central workshop to site. c ) belt clamping, take up lifting and lowering will be in the scope of this contract. d ) decoupling the gear coupling and removal of drive pulley after opening and removal of discharge hood. e ) removal of gear coupling, bearing & plumber blocks. f ) mounting of gear coupling, bearings and plumber blocks on the new pulley. g ) placement of new pulley on position & alignment of the pulley with gear box to the satisfaction of engr. in charge. h ) system normalization trial run & defect rectification, if any. i ) shifting of old pulley to chp workshop / central workshop 10.80 ) . ( fhpcc53bd800 ) crushers ( hammers ) repl replacement of full set hammers replacement of full hammers: a ) weighing of new hammers, weight balancing and shifting them to the site after internal inspection of crusher. b ) removal of hammers from the crusher and replacement of new hammers as per direction of area engineer or his representative. c ) shifting of old hammers to chp scrap yard. d ) any cutting / welding required will be in scope of contractor. 10.90. ( fhscc11bd001 ) cr hammer attend breakdown repl. of hammers in two opposite rows for measurement purpose any one of the following will be treated as separate unit. repl. of hammers in two opposite rows: a ) weighing of new hammers, weight balancing and shifting them to the site after internal inspection of crusher. b ) removal of broken / worn out hammers from the crusher and replacement of new hammers as per direction of area engineer or his representative. c ) shifting of old hammers to chp scrap yard. d ) any cutting / welding required will be in scope of contractor. 10.100 ( fhgzf17bd800 ) grizzly feeders ( shaft assly. ) repl replacement of g.f. shaft / replacement of crusher kick off plate replacement of g.f. shaft ( one no. of shaft ) : a ) removal of guards, universal coupling / cardoon shaft & counter weight. b ) removal of bearings and bearing housings at d.e. & nde c ) shifting of new g.f. shaft to site. d ) removal of old shaft and fixing of new shaft. e ) mounting of bearing housings on the new shaft / replacement of bearing housing if required. f ) remounting of counter weight, universal coupling and their guards. g ) greasing, trial run and defect rectification, if any. h ) shifting of old / damaged g.f. shaft to chp workshop / chp scrap yard. ‘or’ replacement of crusher kick off plate: a ) shifting of kick off plate at site from central store / site store. b ) removal of crusher top cover / side liners if required. c ) opening of kick off plate bolts and removal of frame fill piece. d ) fixing of new frame fill piece, tightening of bolts up to required torque / welding if required. e ) normalization of system. trial run and defect rectification. f ) shifting of old frame fill piece to chp scrap yard or as per direction. 10.110. ( fhvbf00bd000 ) vibro feeders ( <> ) attend defect vibro feeders attend defect / tightening of breaker plate bolt for measurement purpose any one of the following will be treated as separate unit. ( 1 ) . remove the worn out / broken tray from the position. ( 2 ) . replace the same with the new tray / repaired tray with new / same tie rod / tie rope assembly and do proper alignment. ( 3 ) any other minor work like patch work in chute and adjustment in hopper / chute to maintain the freeness of tray with chute etc as per direction of eic. 4 ) take trial after adjusting the tray. 5 ) declination angle adjustment of the as per the direction of eic. 6 ) unbalanced weight adjustment work as per the direction of eic. 7 ) replacement of vibro feeder pedestal spring ‘or’ tightening of breaker plate bolt after welding of head: a ) welding of head of one breaker plate bolt as per requirement. b ) tightness checking of bolt and locking of nuts. c ) any cutting / welding required will be in the scope of the contractor. d ) for measurement purpose tightening of bolt of one breaker plate will be treated as one unit. e ) for welding of heads of breaker plate bolts, e7018 1 electrodes will be supplied by kbunl free of cost. 10.120. ( fhscc17bd800 ) crushers ( rotor assly ) repl crushers ( rotor assly ) repl for measurement purpose any one of the following will be treated as separate unit. replacement of crusher rotor: a ) shifting of new rotor from central store / any other store to crusher floor b ) decoupling of slow speed coupling and removal of pin bush. c ) removal of crusher cover, front side housing, tramp iron tray, plumber block bolts, side liners, hood, chute etc. d ) removal of all hammers and suspension bars. e ) lifting up the rotor and placement at a safe place. f ) removal of coupling half and bearings from rotor. g ) lower the new rotor into position after mounting of bearings, plumber blocks and coupling half. box up in reverse order. h ) check and correct misalignment of slow speed side. i ) balancing of hammers & mounting ( replace full set of hammers if required ) , system normalization, trial run and defect rectification, if any. j ) shifting of old rotor to chp scrap yard. k ) replacement of defective side liners, repairing of ‘v’ shaped deflector plate and other plates if required, also to be done without any extra financial implication. l ) any cutting / welding required for this job will be in the scope of contractor. m ) for welding of heads of liner bolts, breaker plate bolts, screen plate bolts e7018 1 electrodes will be supplied by kbunl free of cost. ‘or’ replacement of g.f. deck side walls ( 01 set =02nos ) : a ) shifting of 02 no. deck side walls from kbunl stores to site. b ) dismantling of bearing housings, bypass chute, side skirt, shaft tubes, spring units, removal of damaged deck side walls after proper supporting of skirts & decks. c ) fixing of new deck side walls & re installation of all dismantled parts. d ) removal of all supports. system normalization, trial run & defect rectification, if any. e ) shifting of damaged deck side walls to chp scrap yard. f ) if only 01no ( one ) g f deck side wall is replaced, 50% payment will be made. b ) cutting / welding required for the job comes under contractor’s scope. 10.130. ( fhpcc52bd800 ) crushers ( screen plate ) repl crushers ( screen plate ) repl / breaker plate / kick off plate / replacement of crusher d.e. bearing / plumber block for measurement purpose any one of the following will be treated as separate unit. replacement of crusher screen plate / breaker plate / kick off plate : a ) shifting of screen plate / breaker plate / kick off plate at site from central store / site store. b ) removal of crusher top cover. c ) opening of screen plate / breaker plate / kick off plate bolts and removal of the same. d ) fixing of new screen plate / breaker plate / kick off plate , tightening of bolts up to required torque / welding if required. this includes fixing of site make screen plates also. e ) normalization of system. trial run and defect rectification. f ) shifting of old screen plate / breaker plate / kick off plate to scrap yard or as per direction. g ) if both upper & lower screen plates are replaced simultaneously, it will be treated as one unit. i ) all allied activity related with screen plate replacement, including cutting / welding or preparation of jig fixtures comes under contractor’s scope. ‘or’ replacement of crusher d.e. bearing / plumber block : a ) shifting of new bearing / plumber block at site. b ) decoupling of gear box from slow speed side and high speed side. c ) removal of flexible coupling half. e ) opening of shaft seal covers on both sides. f ) loosening of both side plumber block bolts and its top cover. g ) removal of top cover of crusher. h ) removal of side liners above the end discs on both sides. i ) lifting of rotor and removal of plumber block and bearing ( de ) . j ) mounting of new bearing correctly and adjusting the clearance to the specified value. k ) placement of plumber block and lowering of rotor. l ) boxing up in reverse order. m ) mounting of coupling, placement of g / b. alignment of rotor with gear box. n ) system normalization and trial run and defect rectification, if any. o ) shifting of old bearing / plumber block to chp scrap yard. p ) cutting / welding required for the job comes under contractor’s scope. q ) if bearing and plumber block are replaced simultaneously no extra payment shall be made, if will be treated as one unit. 10.140. ( fhttr00bd000 ) travelling tripper ( <> ) attend defect travelling tripper rail structure supporting beam bolts tightening / miscellaneous jobs related to travelling tripper for measurement purpose any one of the following will be treated as separate unit. travelling tripper rail structure supporting beam bolts tightening: a ) it includes tightening all bolts of travelling tripper rail supporting beam, structural member, coupling bolts of tripper. or miscellaneous jobs related to travelling tripper such as scrapper adjustment, skirt fixing, eh brakes inspection and adjustment etc. 10.150. ( fhttr22gn808 ) travelling tripper ( tripper wheel ) realignment re railment of trippers : a ) dismantling of tripper bracings / str., as required. b ) lifting of tripper by mechanical means and placing it on the tripper rails. c ) re assembling of all supporting str. as per direction and system normalization. d ) trial run and defect rectification, if any. e ) any cutting / welding required for this job will be in the contractor’s scope. 10.160. ( fhttr00oh001 ) travelling tripper ( <> ) oh overhauling of tripper hand brake / manual brake / ilms pulley bearing flange replacement / flap gate flange bearing replacement / crusher hammer pin replacement for measurement purpose any one of them will be treated as separate unit. overhauling of tripper hand brake / manual brake: a ) removal of damaged hand brake from position. b ) rectification / strengthening of fixing base plate / replacement of shoe etc. c ) refixing of hand brakes by welding / bolting. check for alignment / fouling with rails. e ) system trial run. defects rectification, if any, after trial run. ‘or’ ilms pulley bearing flange replacement ( nde ) a ) shifting of new bearing at site. b ) preparation of jig / fixtures for supporting the ilms. c ) removal of bearing / bearing flange. d ) system normalisation. trial run and defect rectification, if any. e ) if bearing flange is replaced while bearing replacement, it will be treated as one unit. f ) cutting / welding required for the job comes under contractor’s scope. ‘or’ flap gate flange bearing replacement: a ) removal of operating lever / counter weight lever. b ) shifting of new bearing at site. c ) removal of old bearing and mounting of new bearing and greasing. refitting of lever. d ) shifting of old bearing at chp scrap yard. e ) any cutting / welding work will be in the scope of the contractor. ‘or’ crusher hammer pin replacement : a ) opening of access door. opening of shaft seal / removal of pin retainer bolts. b ) shifting of new hammer pin at site, after weighing. c ) removal of damaged hammer pin and replacement with new one. replacement of the same on opposite side also. d ) crusher box up, trial run and defect rectification, if any. 10.170. ( fhttr00bd801 ) travelling tripper ( <> ) repair tripper rail joint welding. removal of old welding & welding as per requirement. welding electrode e7018 1 will be supplied by kbunl free of cost. for measurement purpose one centimeter will be treated one no. for payment purpose 01 cm will be treated as 01 no 10.180. ( fhilm56bd800 ) ilms / obms ( pulley brg ) repl ilms pulley bearing / bearing flange replacement ( de ) / flap gate actuator replacement / replacement of flap gate trunnion bracket for measurement purpose any one of them will be treated as separate unit. ilms pulley bearing / bearing flange replacement ( de ) : a ) shifting of new bearing at site. b ) preparation of jig / fixture for supporting the ilms. c ) removal of drive motor and gear box. removal of bearing / bearing flange. d ) fixing of new flanged bearing and mounting it on the pulley shaft. e ) assembling of the drive, alignment and system normalization. f ) trial run and defect rectification, if any. g ) if bearing flange is replaced while bearing replacement, it will be treated as one unit. h ) cutting / welding required for the job comes under contractor’s scope. ‘or’ flap gate actuator replacement: a ) shifting of new / repaired actuator at site. b ) removal of old actuator and fixing of new actuator. c ) shifting of old actuator to chp workshop. d ) operation checking of flap gate and defect rectification, if any. e ) overhauling of the replaced actuator. or replacement of flap gate trunnion bracket : a ) shifting of new / repaired trunnion bracket at site. b ) removal of old trunnion bracket and fixing of new trunnion bracket. c ) operation checking of flap gate and defect rectification if any d ) shifting of old trunnion bracket to chp workshop. 10.190. ( fhg / b54bd800 ) gear box ( gear replacement ) full set of gear box internals replacement: a ) it includes replacement of full set of internals of any gear box of any drive in c.h.p. b ) shifting of new / repaired gear box internal from chp store / central store / central workshop. c ) decoupling of gear box from h.s. & low speed side & shifting of motor and removal of fluid coupling, if required. d ) dismantling of gear box top cover, end covers etc and removal of its internals and removal of slow speed side coupling half. e ) mounting of coupling half / bearing on shaft and assembling of shafts in the gear box and checking for proper matching. f ) box up of gear box, placement on foundation & placement of motor, replacement of defective oil seals, if required and oil filling up to the mark. g ) system normalization after alignment. h ) if removal & mounting of fluid coupling / flexible coupling half is required, payment will be done as per sl. no. 01 i ) trial run and defect rectification, if any. j ) shifting of old gear box internals to chp workshop / central work / scrap yard. k ) any cutting / welding work will be in the scope of the contractor. 10.200. ( fhg / b51bd800 ) gear boxes ( i / p shaft ) repl replacement of gear box input shaft / shaft bearings / oil seals / complete gear box / replacement of output shaft for measurement purpose any one of them will be treated as separate unit. replacement of gear box input shaft / shaft bearings / oil seals / complete gear box: a ) replacement of input shaft / shaft bearing / oil seals of any gear box in chp comes under this. b ) shifting of shaft / shaft bearings / oil seals from central store / chp store / central store to site. c ) decoupling of input shaft from motor and shifting of motor to the required place. d ) removal of fluid coupling or brake drum / oil seals after dismantling of thruster brake, if required. e ) opening of gear box top cover etc and removal of the input shaft, oil seals, removal of bearings etc from the shaft. f ) mounting of bearings and hub on the input shaft, replacement of oil seals if required. g ) fixing of input shaft and also to be checked for proper matching with intermediate shaft. h ) box up of gear box in reverse order. i ) mounting of fluid coupling, & motor placement. j ) alignment k ) system normalization, trial run and defect rectification, if any. l ) cutting / welding required for the job comes under contractor’s scope. m ) shifting of old damaged shaft to chp scrap yard / central workshop. n ) if shaft, oil seals and bearings are replaced simultaneously, it will be counted as one unit only. or replacement of output shaft / shaft bearing / oil seals: a ) replacement of output shaft / shaft bearings / oil seals of any drive in c.h.p. comes under this. b ) shifting of new / repaired shaft / shaft bearings / oil seals at site and removal of coupling half c ) decoupling of gear box on slow speed side, removal of gear box top cover & end cover. d ) removal of output shaft / bearings / oil seals etc. e ) internal inspection & mounting of bearings and coupling half on the output shaft. f ) placement of the output shaft. g.box box up, and system normalization. replacement of defective oil seals, if required. g ) trial run and defect rectification, if any. h ) cutting / welding required for the job comes under contractor’s scope. i ) shifting of old damaged shaft / bearings to central workshop. / chp scrap yard j ) if shaft , oil seals and bearings are replaced simultaneously , it will be counted as one unit only. 10.210. ( fhg / b12bd800 ) gear boxes ( 10 50ltrs ) repl replacement of gear box oil : ( oil qty. < 50 ltrs. ) any of the following work is covered under this item. for measurement purpose any one of them will be treated as separate unit. replacement of gear box oil : ( oil qty. < 50 ltrs. ) a ) replacement of oil of any gear box comes under this having oil capacity more than 10 ltrs.. b ) shifting of oil / oil drums from chp store to the site. c ) draining of oil in a can and shifting it to chp scrap yard. d ) filling of oil in the gear box after flushing. normalisation of the system. or de coupling, coupling and alignment of ilms motor. 10.220. ( fhg / b13bd800 ) gear boxes ( 50 100 ltrs ) repl replacement of gear box oil : ( oil qty.> 50 ltrs. ) / replacement of cable reeling drum gear box for measurement purpose any one of them will be treated as separate unit. replacement of gear box oil : ( oil qty.> 50 ltrs. ) a ) replacement of oil of any gear box comes under this . b ) shifting of oil / oil drums from chp store to the site. c ) draining of oil in a can and shifting it to chp scrap yard. d ) filling of oil in the gear box after flushing. e ) normalisation of the system. ‘or’ replacement of cable reeling drum gear box : a ) replacement of crd gear box of travelling tripper comes under this .shifting of new / repaired gear box at site. b ) removal of motor after decoupling of coupling. removal of crd drum if required. c ) removal of gear box and removal of coupling half. d ) mounting of coupling half in new gear box. e ) placement of new gear box in position re assembling of motor. f ) trial run and defect rectification. 10.230. ( fhg / b00gn152 ) gear boxes ( <> ) decpl / cpl / algn alignment of lt drive ( for motor 15 kw to 200kw ) / overhauling of gear box ( below 30 kw ) / ilms gear box replacement for measurement purpose any one of them will be treated as separate unit. alignment of lt drive ( for motor 15 kw to 200kw ) : a ) if coupling pin bush replacement is required, no extra payment will be done. b ) it includes all related activity for the alignment. c ) for payment purpose, if both slow speed ( with dial gauge ) and high speed alignment is done, it will be treated as separate unit. d ) cutting / welding required for the job comes under contractor’s scope. ‘or’ overhauling of gear box ( below 30 kw ) : a ) opening of gear box. replacement of defective / worn out / damaged parts. b ) re assembling of gear box and oil filling. ‘or’ ilms gear box replacement: a ) shifting of new / repaired gear box at site. b ) decoupling and removal of motor. decoupling and removal of gear box. c ) mounting of new gear box, re assembling of motor and alignment. d ) coupling of motor, trial run and defect rectification, if any. e ) shifting of old gear box at chp / central workshop. 10.240. ( fhttr14bd800 ) travelling tripper ( lt gearbox ) repl replacement of travelling tripper travel drive gear box / alignment of ht drive ( for motor above 200 kw ) for measurement purpose any one of them will be treated as separate unit. replacement of travelling tripper travel drive gear box : a ) shifting of new / repaired gear box at site. b ) dismantling of old gear box / motor and fixing of new gear box & motor. c ) dismantling of thruster brake & refixing. d ) alignment of the drive and oil top up in new gear box after flushing. e ) normalization of the system and trial run to be taken. defect rectification, if any. f ) shifting of all materials to chp store / chp scrap yard. g ) cutting / welding required for the job comes under contractor’s scope. ‘or’ alignment of ht drive ( for motor above 200 kw ) : a ) if coupling pin bush replacement is required, no extra payment will be done. b ) it includes all related activity for the alignment ( slow speed or high speed ) . c ) for payment purpose, if both slow speed ( with dial gauge ) and high speed alignment is done, it will be treated as separate unit. d ) cutting / welding required for the job comes under contractor’s scope. 10.250. ( fhg / b00bd000 ) gear boxes ( <> ) attend defect gear box gauge glass replacement / replacement of sump pump spider of love joy coupling for measurement purpose any one of the following will be treated as separate unit. a ) gear box gauge glass replacement: b ) shifting of new / repaired gauge glass at site. c ) removal of old gauge glass after isolation and mounting of new one. d ) oil leakage job of gear box ‘ or ‘ replacement of sump pump spider of love joy coupling : a ) no payment will be made for spider of love joy coupling replacement if it is done while pump overhauling. 10.260. ( fhmat14gn863 ) matl ( misc ) shifting transportation of materials: a ) it includes transportation of any kind of material from central store or any other place inside plant to chp store or vice versa, as per direction. b ) for measurement purpose materials upto 50kg or part there off will be taken as one unit. 10.270. chp em bkdn mtc st 1 ( fhmat11gn162 ) matl ( scrap ) disposal transportation of misc. scrap: a ) it covers transportation of misc. scrap from chp area to other place inside the plant as per direction. b ) for measurement purpose transportation of one ton scrap will be taken as one unit. all arrangement for loading, unloading and transportation including supply of tractor is in contractor’s scope. 10.280. ( fhmsw00gn250 ) fabrication erection ( <> ) lighter section miscellaneous steel fabrication work in c.h.p. ( lighter section ) : a ) fabrication of ladder , platform and other miscellaneous work in chp and mgr area ( from wagon tippler to bunker floor and mgr gates ) at different elevations and different location comes under this . b ) transportation of steel from kbunl stores to work site . c ) fabrication work is to be done as per given drawing or as per direction of area engineer and placement of the same at the required place or as per direction. d ) new fabricated work is to be painted with one coat of primer paint of kbunl approved brand. paint to be provided by the contractor. e ) payment will be done on per ton basis. f ) it will be applicable for steel sheets upto 3.15mm. g ) removal of old plate / structure from location and shifting to chp scrap yard will be in the scope of the contractor. 10.290. ( fhcht00bd801 ) chutes ( <> ) repair coal leakage arresting by patch work : a ) arresting of coal dust leakage from any chute / duct in chp comes under this. b ) leakage arresting includes fabrication of required patch from ms plate ( up to 20mm thick ) and welding of the same at required place or as per direction of area engineer. c ) trial run for leakage arresting if any. d ) for measurement purpose payment will be made on per unit basis and 300 mm*300 mm will be treated as one number. 10.300. ( fhcht00gn250 ) ( fabrication +erection ) miscellaneous steel fabrication work in c.h.p. ( heavy section ) .: a ) fabrication of ladder, platform and other miscellaneous work in chp and mgr area ( from track hopper to bunker floor and mgr gates ) at different elevations and different location comes under this . b ) transportation of steel from kbunl stores to work site . c ) fabrication work is to be done as per given drawing or as per direction of area engineer and placement of the same at the required place or as per direction. d ) new fabricated work is to be painted with one coat of primer paint of kbunl approved brand. paint to be provided by the contractor. e ) payment will be done on per ton basis. f ) removal of old plate / structure from location and shifting to chp scrap yard will be in the scope of contractor. 10.310. ( fhdep00gn602 ) deptt <> man.dep sw manpower supply sw manpower supply for other miscellaneous work ( as per direction of engr in charge ) . necessary t&ps required for supply job will be provided by contractor ( as per t&ps list ) . sw ( fitter / rigger / welder ) 10.320. ( fhdep00gn600 ) deptt <> man.dep usw manpower supply usw manpower supply for other miscellaneous work ( as per direction of engr in charge ) . necessary t&ps required for supply job will be provided by contractor ( as per t&ps list ) usw ( helper ) 10.330. ( fhscc13gn250 ) crushers ( bkr plate ) fabrication crushers ( bkr plate ) fabrication / deck plate fabrication of vs assembly making breaker plate for crusher ( one full set consisting of four piece small / 02pc big size ) a ) marking of breaker plate as per drawing and instruction of area engineer. b ) cutting of breaker plate. c ) transportation of breaker plates from chp steel yard to central workshop for drilling. d ) transportation of breaker plates from central workshop to chp crusher house / store area after drilling. drilling of holes will not be in the scope of the agency. payment will be made as ( 04 nos = 01 unit ) or a ) fabrication of deck plates of vibrating screen 10.340. conv pulleys ( <> ) brg inspection: fhcnp00bd799 conv. pulley ( <> ) brg inspection bearing inspection for conveyor pulley / crusher / bearings of wheels of mobile equipment’s stacker , travelling tripper bearing inspection a ) inspection of bearings ( both end ) of any conveyor pulley in chp. b ) supply of all t&ps and manpower will be in the scope of the agency. c ) all related jobs for bearing inspection will be in the scope of the agency. d ) greasing of bearings after inspection to be done by the agency. 10.350. ( fhbcn02pm002 ) belt conveyor 02 w checks belt conveyor 02 w checks 1. any conveyor in chp is covered under this item. 2. check all idlers for free rotation. 3. replace defective idlers / idlers frame / guide rollers, 4. adjust / replace the skirt rubber, scrapper rubber & dust curtains. 5. check the belts for any sway, train as required. 6. check the thruster oil level, top up if required .adjust the thruster brake. 7. check the gear box & fluid coupling oil level / leakage, top up if required. clean the gear box breather. 8. check the belt joints for any ply separation, check the belt for any damage, cut mark etc.& report. 9. check pulley bearing for overheating, noise etc. check the temp. of gear box. check oil pressure if gauge is provided. 10. check that take up travel is free; there is no deformation in its guide. 11. tighten all foundation bolts of motor, gear box, pulley, plumber block etc. 12. any cutting / welding / tacking of idler with frame is in the scope of contractor. 10.360. ( fhbcn02pm004 ) belt conveyor 04 w checks belt conveyor 04 w checks 1. any conveyor in chp is covered under this item. 2. repeat items 2, 3, 4, 5, 6, 7, 8, 11&12 of job sl.no. – 35 3. check tightness of fan bolts & foundation bolts of drive & pulley. 4. check for any leakage from the seals of gear box fluid coupling and report. 5. check the play in pin & bush coupling and report if bushes are damaged. 6. inspect pulley lagging for wear / damage & report. 7. check the pulley for any crack; tighten the locking assembly bolts by torque wrench unto adequate torque. 8. check that there is no deformation in take up guide. 10.370. ( fhbcn02pm012 ) : belt conveyor 12 w checks belt conveyor 12 w checks 1. any conveyor in chp is covered under this item. 2. repeat all items of sl. no. –36. 3. check oil level of fluid coupling, top up if required. 4. grease pulley bearings & gear coupling & take up guides. 5. check proper functioning of thruster brakes adjust, if required. 10.380. ( fhilm00pm002 ) : ilms 02 w checks ilms 02 w checks 1. any in line magnetic separator in chp is covered under this item. 2. inspect belt for any damage. check belt sway / belt tension, adjust, if required. 3. check gear box oil level, top up, if required. check tightness all foundation bolts. 4. adjust / replace the skirt rubber. 10.390. ( fhilm00pm004 ) ilms 04 w checks ilms 04 w checks 1. any in line magnetic separator in chp is covered under this item. 2. repeat all items of job sl.no. – 38 3. grease all bearings of plumber blocks. grease the screw take up. 10.400. ( fhgzf00pm002 ) : grizzly feeder 02 w checks grizzly feeder 02 w checks 1. any grizzly feeder in crusher house is covered under this item. 2. check tightness of the foundation bolts of motor, grizzly feeder bearing housing, seal cover and any other. 3. ch. tightness tray fixing bolts, chute fixing bolts, counter weight, fixing bolts. 4. check coal leakage from gf, adjust / replace rubber dust seals. 5. clean the deck and check the welding . 6. check welding of liners. 7. check the condition of spring & reports. 8. clean the bypass chute. inspect the deck sidewalls for any crack & report. 9. any cutting / welding required is in the scope of contractor. 10.410. ( fhgzf00pm004 ) : grizzly feeder 04 w checks grizzly feeder 04 w checks 1. any grizzly feeder in crusher house is covered under this item. 2. repeat all items of job sl.no. – 40 3. grease all bearings. check condition of universal joints & propeller shaft. 10.420. ( fhpcc00pm002 ) : crushers ( <> ) 02w chks crushers 02w chks 1. any crusher in crusher house is covered under this item. 2. check the condition of hammers and report. 3. ch. gear box oil levels, top up, if required. clean the air breather / replace the gauge glass if required. remove foreign materials from tramp iron box. 4. check for any coal leakage from manholes, inspection holes etc. & arrest the leakage. 5. check tightness of all cage fixing bolts, housing bolts etc. 6. check breaker plate, shaft disc key , screen plate, frame fill piece, v shaped deflector plate, screen plate arm, liners, screw jack ( cage adjuster ) , screen clamp bar for wear and report. check the tightness of bolts and weld the bolts, if required. 7. check tightness of all bolts & nuts of gear box fan, plumber blocks & foundation bolts. 8. clean the pressure equaliser line. 9. any cutting / welding required is in the scope of contractor. 10.430. ( fhpcc00pm004 ) : crushers ( <> ) 04w chks crushers 04w chks 1. any crusher in crusher house is covered under this item. 2. repeat all items of job sl.no. – 42 3. grease nde & de bearing of crusher, cage adjusting device. 4. check fluid coupling oil level, top up, if required. ( to be done after three months ) 5. inspect breaker plate holding plate and report. 10.440 ) . ( fhttr00pm002 ) : traveling tripper 02 w checks traveling tripper 02 w checks 1. any traveling tripper in chp is covered under this item. 2. check all idlers of the tripper for free rotation / abnormal noise. 3. replace the defective idlers / idler frames. place fallen idlers. 4. check oil level / oil leakage of travel drive gear box, crd gear box and thruster, top up, if required. check / adjust tightness of thrustor brake shoe. 5. check and adjust tripper hand brake / rail cleaner. 6. check tightness of all foundation bolts of motor, gear pulley etc 7. check flap gate actuator is operating freely & closing properly. 10.450 ) . ( fhttr00pm004 ) : traveling tripper 04 w checks traveling tripper 04 w checks 1. any traveling tripper in chp is covered under this item. 2. repeat items 3, 4, 5 , 6 & 7 of job sl.no. – 44 3. check gear box air breather for clogging, clean, if required. 4. check pin bush for coupling and report for replacement, if required. 5. check tripper rail welding joints. check tightness of rail supporting structure bolts at joint, if welding is broken. 10.460 ) . ( fhs / r00pm002 ) : stacker 02 w checks stacker 02 w checks a ) boom conveyor: 1. check all idlers for free rotation, replace defective idlers / idler frame. 2. check / adjust / replace skirt rubber, scrapper rubber, dust curtains. 3. check the belt for any sway, train, if required. 4. check the oil level, top up if required. clean the air breather. 5. check free movement of thrusters, clean dust etc. from moving zone. b ) intermediate conveyor : 1. check all idlers for free rotation, replace defective idlers. 2. check / adjust / replace skirt rubber, scrapper rubber, dust curtains. 3. check the belt for any sway, train, if required. 4. check the oil level, top up if required. clean the air breather. 5. check free movement of thrusters, clean dust etc. from moving zone. c ) pcrd / ccrd 1. check proper functioning of pcrd / ccrd, rectify if required. 2. check tightness of chain, sprocket, and foundation bolts etc. 3. check oil level of angle gear box, top up, if required. 10.470 ) . ( fhs / r00pm004 ) stacker 04 w checks stacker 04 w checks a ) boom conveyor : 1. check and adjust / replace the rubber strip of scrappers / skirt rubber. 2. check the oil level of gear box, top up, if required. clean the air breather, if required. 3. check for any leakage from the seals of gear box, fluid coupling. 4. check the play in pin bush coupling, report for replacement, if required. 5. inspect pulley lagging for wear / damage. 6. tighten all foundation bolts of motor, gear box, pulley. 7. check the screw take up travel is free and there is no deformation in its guides. check the belt tension, tighten, if required. 8. check functioning of thrusters / thrustor brakes, rectify as required. b ) intermediate conveyor : 1. check and adjust / replace the rubber strip of scrapper / skirt rubber. 2. check oil level of gear box, top up, if required. clean the air breather. 3. check for any leakage from the gear box, fluid coupling. 4. check the play in pin push coupling, report for replacement, if required. 5. check pulley lagging for wear / damage. 6. tighten all foundation bolts of motor, gear box, pulley. 7. check that screw take up guide travel is free and there is no deformation in its guide. check belt tension, tighten, if required. 8. check functioning of thrustors / thrustor brakes, rectify as required. c ) pcrd / ccrd 1. check the freeness of cable rollers. 2. check & adjust cable and cable guide. 3. check the angle gear box oil level, top up, if required. 4. check tightness of foundation bolts, chain, sprocket etc. 5. grease all plumber block bearings. 6. check tightness of chain, sprocket and foundation bolts etc. 10.480 ) . ( fhfpg00pm004 ) flap gate 04 w checks flap gate 04 w checks 1. any flap gate in chp is covered under this item. 2. check oil level in the actuator gear box, top up, if required. 3. grease both side bearing of flap gate and actuator. 4. check actuator is operating freely & closing properly both sides. 5. check tightness of foundation bolts. 6. check for any wear of the flap gate surface & report. 7.check for any possible coal passing through flap gate. 8. any cutting / welding required is in the scope of contractor. 10.490 ) . ( fhrpg00pm004 ) rake & pinion gate 04 w checks rake & pinion gate 04 w checks 1. any rake & pinion gate in crusher house is covered under this item. 2. oil top up in the rpg’s both gear boxes, if required. 3. check freeness of chain sprocket wheel. 4. greasing of all the bearings. 5. check tightness of all the foundation bolts. 6. check rack & pinion gate assembly for freeness. 10.500 ) . ( fhpit03pm004 ) sump pumps 04 w checks sump pumps 04 w checks 1. for measurement purpose one pump of t / h sump pumps / lwtp vertical pump will be taken as one unit. 2. greasing of pumps bearings. 3. check the rubber spider of the coupling, replace, if required. 4. check the play in pump motor coupling, adjust, if required. 5. check tightness of foundation bolts. 6. check leakage from pipe joints & valve gland. 7. check freeness of nr valve and gate valve. 10.510 ) . ( fhdes00pm004 ) : de / ds system 04 w chks. de / ds system 04 w chks / water line checking / general checking and defect rectification of ventilation system / general checking of de system any of the following work is covered under this item. for measurement purpose any one of the following will be treated as separate unit. general checking and defect rectification of dust suppression system in tps, stacker, crusher house & wagon tippler area . pump: a ) greasing all bearings of the pump. b ) replacement / tighten the gland packing of the pump as required. c ) check any water leakage and report. check pin bush coupling condition, replace if required. d ) check tightening of all foundation bolt. or water line checking: a ) clean the pump suction strainer ( pot strainer ) & y strainer. b ) attend water leakage if any , including from hose pipe. c ) check the spray nozzle condition and report. or general checking and defect rectification of ventilation system. a ) greasing of all bearings. b ) check v belt condition, replacement and alignment if requiared. c ) check tightness of all foundation bolt. d ) rotate the fan impeller by hand and report if any abnormality is observed. e ) check the stud nut tightness of impeller. or general checking of de system. a ) greasing of all bearings. check v belt condition, replacement and alignment if required. b ) check tightness of all foundation bolt. c ) rotate the fan impeller by hand and report if any abnormality is observed. d ) check the stud nut tightness of impeller. e ) cleaning of rotary lock feeder unit and its discharge pipe. 10.520 ) . ( fhmsl01bd800 ) — de / ds / service water line & fire line defect attend replacement of pipe line , replacement of gate valve / nrv / laying of pipe line replacement of pipe line , replacement of gate valve / nrv a ) ds / de / service water line in chp / fire water b ) shifting of new pipe line at site and replacement of old pipe line. c ) any cutting welding required for the job comes under this. d ) while replacement necessary flange, gasket, fittings are also to be changed, if required. e ) shifting of old pipe line to chp scrap yard. trial run and defect rectification. f ) for measurement purpose a segment of 01 mtr length or part there of will be treated as one unit for pipe line up to 65 nb . g ) for measurement purpose a segment of 01 mtr length or part there of will be treated as 1.2 unit for pipe line 80 nb and above . or laying of pipe line a ) it covers laying of pipe line ( with fittings ) in ds / de / service water line in chp / fire water. b ) shifting of new pipe line at site. c ) while laying of pipe line necessary flange, gasket, fittings are also to be provided, if required. any cutting welding required for the job comes under this. e ) trial run and defect rectification. g ) application of 2 coats of red oxide primer paint on the pipe, red oxide primer paint is in the partys scope. h ) for measurement purpose a segment of 2mtr length or part there of will be treated as one unit for pipe up to 65nb. i ) for measurement purpose a segment of 2 mtr length or part there of will be treated as 1.15 unit. for pipe 80nb and above. 10.530 ) . ( fhlpp01bd000 ) ds pump gland packing rep. or adj. / ds pump coupling pin bush rep. / ds / de pump / fan bearing greasing / servicing of solenoid valves in ds line ‘or‘ replacement of v bells ( full set ) / rep.of vent. fan air filter / dust suppression system nozzles nipple fixing / cleaning of spray nozzles in dust suppression system any of the following work is covered under this item. for measurement purpose any one of the following will be treated as separate unit. ds pump gland packing replacement / adjustment: a ) replacement / adjustment of the gland packing of the pump for arresting water leakage. ( one side or both side as required ) . trial run and adjustment of the glands. or ds pump coupling pin bush replacement : replacement of full set of pin bush will be taken as one unit. or cleaning of y strainer in ds line : removal of the y strainers from the system, cleaning it upto the satisfaction and re fitting at original position. or servicing of valves in ds line: a ) dismantling of solenoid v / v, replacement / repairing of defective parts and reassembling. or replacement of v bells ( full set ) : a ) removal of fan belt guard. removal of damaged v belts. shifting of new v belts and fixing on the v pulley. alignment of the pulleys. trial run and defect rectification. or replacement of ventilation fan air filter ( 01 no = 01 unit ) : a ) removal of air filter from system. b ) shifting of new / repaired air filter and installation. c ) drying of the filter and fixing back to its original location. d ) rectification of minor repair is for the filters if required, or greasing of fan / pump bearings ( both bearing ) or dust suppression system nozzles nipple fixing a ) nipple to be fabricated from ½ inch, medium duty pipe, length of nipple will be 3 to 4 inches. b ) removal of damaged nipple & fixing of new . c ) fixing of spray nozzle on the nipple. or cleaning of spray nozzles in dust suppression system : a ) removal of spray nozzles from the dust suppression system. dismantling of nozzles , cleaning and re fixing it at original position. b ) for payment purpose 05 nos. of nozzles or part thereof will be treated as one unit. 10.540 ) . ( fhdes01bd800 ) replacement of fire sprinklers / replacement of fire hydrant valve / repairing of fire hydrant valve any of the following work is covered under this item. for measurement purpose any one of the following will be treated as separate unit. replacement of fire sprinklers : a ) isolation of the sprinkler line from water side if required. removal of damaged sprinkler and fixing of new one. charging of the line with water and leakage arresting if any. or replacement of fire hydrant valve: a ) replacement of any fire hydrant valve in chp is covered under this. b ) shifting of new / repaired fire hydrant valve to site and replacement of the defective valve. c ) shifting of damaged fire hydrant valve to chp workshop. or repairing of fire hydrant valve: a ) dismantling of fire hydrant valve, replacement of defective parts and re assembling. b ) spares will be provided by kbunl free of cost. however, for rubber washer, it is to be cut from rubber sheet, supplied. 10.550 ) . ( fhmsl01bd000 ) water leakage arresting from pipe line / flange ( above ground ) leakage arresting includes welding / gasket replacement / pipe fitting replacement, if any. 10.560 ) . ( fhmsl01bd801 ) / ms piping ( dia<=6 ) repair water leakage arresting from pipe line / flange ( under ground ) a ) leakage arresting includes welding / gasket replacement / pipe fitting replacement, if any. b ) dewatering of the pit, if required. dewatering pump will be provided by kbunl free of cost, if available. c ) proper cleaning of pipe surface for welding at leakage area & leakage arresting through patch work or as per direction of area engr. d ) if more than one leakage is found in one digging, it will be treated as one unit. e ) underground pipes are at 1.5m depth ( approx. ) . f ) application of wrapping & coating on pipes / patches etc. all materials in the partys scope. . 10.570 ) . ( fhdep00gn624 ) ( deptt <> manpower gang ( adl ) ) maintenance jobs per shift ( shift maintenance ) : 1. contractor has to deploy 02 ( 1 welder + 1 fitter ) , and 2 helper and one rigger for chp mechanical maintenance in shift as and when asked by eic. 2. they will be deployed for emergent type of job which are mentioned below: 3.oil topping up in gear box / fluid coupling 4. removal & fixing of coupling guards 5. opening & closing of front & back doors of crushers. 6. assistance in changing of flap gate during path selection. 7. v belt replacement if required 8. adjustment / replacement of skirt rubber 9. belt scrapper replacement / adjustment 10. patching of chute puncture 11. belt training if required 12. removal / replacement of idlers if required 13. any job assigned by eic. 10.580 ) . misc. maint. work ( code: fhmsw00bd000 ) misc. maint. work defect liability period: 01 month. a ) .cat a ( completion period 04 hrs. ) 01. belt weight, counter weight adjustment 02 key preparing / key way repair 03 hydraulic jack repair. 04 canopy cover making & fixing. 05 back plate removal & fixing. 06 inspection door removal & fixing. 07. hold back removal & fixing. 08. wiper replacement & fixing. 09. pcrd / ccrd guide roller repair replacement ( per roller ) . 10. chute chocking removal. 11. limit switch / striker fixing / sr striker fixing . 12. oil topping / oil replacement ( 01 to 50 liters ) 13. removal of hold back engagement bolt ( per conveyor ) 14. cutting set / welding m / c. shifting / material shifting 15. breather plug and gauge glass cleaning / fixing ( per gearbox ) . 16. walk way step repair & fixing 17. hs coupling bolt and bush replacement ( per coupling ) . 18. fcu oil adjustment ( per fcu ) . 19. suspension bar locking per bar. 20. coupling bolt locking through welding per bolt ( ls ) . 21. inspection cover fixing. ( per chute ) 22. crusher door sealing per crusher. 23. bearing checking / greasing ( per bearing ) . 24. r.p.g opening and closing. 25. fixing / removal of zss. 26. coupling & decoupling of equipment’s. 27. pcrd / ccrd cable positioning. 28. rail fish plate bolt replacement. 29. take up wire rope greasing / lubricating compound. 30. flap gate actuator arm pin removal & fixing. 31. hose / pipe clamp fixing 32. bolt fixing in chute bolt hole. 33. belt training / belt swaying to be aligned. 34. o ring rubber chord to be provided in input / output shaft of gear box. 35. vs ‘v’ belt set replacement & alignment. 36. fastening of belt by belt fastener ( 02 fastener for 1no.cat a ) 37. vs upper deck and lower deck repairing 38. misc. belt related jobs 10.590 ) . misc. maint. work ( code: fhmsw00bd001 ) misc. maint. work defect liability period: 01 month. a ) .cat b ( completion period 06 hrs. ) 01. gear box / conveyor ls coupling bolt removal & fixing 02. winch m / c shifting & welding at location. 03. sealing belt tensioning ( per conveyor ) / bunker sealing ( per unit ) 04. hold back replacement. 05. l.s. coupling bolt replacement ( per bolt ) 06. crusher cooler servicing. 07. chute flange joint leakage sealing / arresting by welding. 08. inspection cover replacement. 09. crusher rotor locknut tightening. / cr. bearing lock nut tightening. ( per crusher ) 10. v.s. hinge bush block replacement. 11. tripper / sr crack & broken wheel repairing. 12 fcu multi disc replacement. 13. foreign material removal. 14. r.p.g gear box replacement. 15. elect. brake shoe / manual brake adjustment / repairing. 16. gear box inspection cover removal for internal inspection 17.welding of rail / conveyor short support / stringer post / ladder repair. 18. grill repairing. 19. fg shaft bolt replacement. 20. repair of rail crack by welding. 21. shaft repairing ( welding / grinding ) . 22. chute block switch positioning and repairing. 23. pcrd / ccrd hanger repairing of sr / mt etc. 24. motor / gear / tail pulley / head pulley etc canopy or guard / cover preparing & fixing 25. key way making. 26. key making for coupling. 10.600. code: fhwgt00pm002 02 weekly checks of wagon tippler ( completion period 08 hours ) a. checking / repairing of ls & hs coupling bolts. b. checking / repairing of gear box oil level. c. checking / repairing of structures ( ballast container , way bridge, rail table, etc. ) d. checking / repairing of pinions. e. checking / repairing of connecting shafts. f. checking / repairing of power lever. g. checking / repairing of spill plates &rollers. h. checking / repairing of civil foundations. i. checking / repairing of all plummer blocks. j. checking / repairing of bull gears. k. checking / repairing of splice joints of structures. l. checking / repairing of otls switch etc. m. checking / repairing / installation of brake shoes. n. greasing of bearings by grease gun. o. checking & repairing of load shell & weigh bridge. p. spill plate roller & bracket checking / repairing. 10.610 ) code: fhwgt00pm004 04 weekly checks of wagon tippler ( completion period 10 hours ) a. checking / repairing / replacement of ls & hs coupling bolts. b. checking / repairing of gear box oil level. c. checking / repairing of structures ( ballast container , way bridge, rail table, etc. ) d. checking / repairing of pinions. e. checking / repairing of connecting shafts. f. checking / repairing of pall lever. g. checking / repairing of spill plates &rollers. h. checking / repairing of civil foundations. i. checking / repairing of all plummer blocks. j. checking / repairing of bull gears. k. checking / repairing of splice joints of structures. l. checking / repairing of otls, cam switch etc. m. checking / repairing of brake shoes. n. greasing of bearings by grease gun. o. providing of servo coat 140 on pinion & bull gear. p. all points of 02 weekly checks. 10.620 ) code: fhwgt00pm012 12 weekly checks of wagon tippler ( completion period 10 hours ) a. checking / repairing / replacement of ls & hs coupling bolts. b. checking of gear box oil condition / replacement if required. c. checking / repairing / replacement ( partly ) if required. ( ballast container , way bridge, rail table, etc. ) d. checking of bearing clearances of pinions & replacement if required. e. checking / repairing / alignment of connecting shafts. f. checking / repairing / adjustment of pawl lever. g. checking / repairing / replacement of spill plates & rollers. h. checking / repairing of civil foundations. i. checking / repairing of all plumber blocks. j. checking / repairing / replacement of bull gears ( partially ) if required. k. checking / repairing of splice joints of structures. l. checking / repairing of otls, cam switch etc. m. checking / repairing of brake shoes. n. greasing of bearings by grease gun. o. all points of 02 weekly & 04 weekly checks. 10.630 ) . code: fhwgt00gn402 inspection of wagon tippler / calibration ( completion period 04 hours ) a. checking of ls & hs coupling bolts. b. checking of gear box oil level. c. checking of structures ( ballast container , way bridge rail table, etc. ) d. checking of pinions. e. checking of connecting shafts. f. checking of pawl lever. g. checking of spill plates & rollers. h. checking of civil foundations. i. checking of all plummer blocks. j. checking of bull gears. k. checking of splice joints of structures. l. checking of otls, cam switch etc. m. checking of brake shoes. n. checking of top stop clamps and side supports & rubber o. checking of photo sensor for operation. p. weigh bridge & load shell checking 10.640 . ( fhscc00gn402 ) crushers / vibrating screen ( <> ) inspection ( a ) . remove top cover of the secondary crusher to facilitate internal inspection & cleaning. ( b ) . replace missing / loose / broken fasteners of the breaker plate / cage screen / kick off plate / tramp iron tray / end disc liner etc. ( c ) . refix the same after work is over. or ( a ) .check the condition of support springs and do the necessary adjustment / replacement. ( b ) . check and rectify the defect in the tray and its structural members. ( c ) . check receiving and discharge chute liners and report. rectify minor repair in the coffin box. ( d ) . replace the worn out skirt rubber / dust curtain. ( e ) . any other minor work has to be carried out as per direction of eic. 10.650 fheoh00oh000 ( elec hoists ( <> ) serv ) a ) . placing the hoist at suitable position for maintenance and arrange proper approach for maintenance ( b ) . opening the housing drum cover of hoist. ( c ) . checking of gears / gear box internals. repair / replace as required. clean and grease all the gears ( d ) . checking, cleaning & lubricating the bearings. replace the bearings, if reqd. ( e ) . checking the rope drum & repair / replace the parts as required. lubricate the parts needing lubrication. ( f ) . checking the rope for any defect and broken strands, replace the rope if required. clean, lubricate the rope. ( g ) . checking the load hook block assembly. clean & grease the parts. attend the defect. also check the hook for any cracks / deformation. ( h ) . cleaning and greasing guide ring and retaining ring to ensure rotation / reeling. ( i ) . checking of all the bolts, nuts and tension bar ensuring proper tightness and good condition. ( j ) . check the travel wheel and its mechanism and repair / replace as required. ( k ) . take trial of hoist on both the ends. ensure proper mechanical stopper. also check the hoist operation by lowering / raising as per limit. ( l ) . ensure proper braking of hoist on no load as well on load both. ( m ) . checking of hoist for any other defect and rectify the same. 10.660 ( fhsai00gn869 ) self algn idlr ( <> ) servicing ( servicing of trainer idler / repair of carrying / return / impact idlers ) completion time 02 hours. defect liability period 03 months. for payment purpose repair of one idler or one self adjustable frame will be considered as one unit. ( i ) servicing of trainer idler ( a ) removal of self aligning troughing trainer & return side trainer complete assembly from its position. ( b ) over haul the pivot bearing & bush by cleaning the old grease with solvent / cleaning agent, and then regrease the bush / bearing. if required, replace the bearing. ( c ) separate cloth to be used for removing the old grease, and wiping off the solvent from the bearing to avoid contamination. ( d ) optimum grease to be used such that the pivot bush / bearing is properly lubricated. grease shall not be wasted by overfilling in the housing. ( e ) re fix the complete frame back in its position, and properly tighten the bolts. if the bolts are damaged, or missing, then new bolts are to be fixed so that the frame is properly secured. ( f ) grease, bush / bearing & fasteners shall be provided by ntpc. rest all the materials & tools for cleaning to be provided by the contractor. ( g ) after complete servicing of the self adjusting idlers, clean the deposited coal on the surface of remaining rollers by soft hammering and poking. ( h ) if required, rollers are to be removed from the frames for cleaning, coal to be cleaned from the frame slots, and near bearing housing & then fixed back. ( i ) if required, also check the rollers of the assembly for their freeness, and if jammed or damaged, rollers shall be replaced. payment for roller replacement shall be made separately. ( ii ) repair of carrying / return / impact idlers ( a ) . shift damaged rollers from site or wherever dumped to work location. ( b ) . dismantle roller internals like seals, bearings, and shaft etc. ( c ) . clean roller internal properly. ( d ) . select roller shells in good condition. ( e ) . repair damaged shaft by cutting / welding / grinding. ( f ) . assembly of roller with new / good condition bearings, seals, bushes and circlips and check freeness. ( g ) . apply one coat of red oxide primer over the roller surface and put serial number on the same. total quantity :...

Eastern Railways - Bihar

43325117 supply of door way cross bardoor way cross bar,door way cross bar pressing with back plate and packing piece in assembled condition for boxn wagon as per rdso drg. no. wd 08007 s 05,item 2,14 & 15, alt 29 as per drg.no. drg no.wd 08007 s 05,it em 2,14 & 15 alt 29 [ warranty period: 30 months after the date of delivery ]...

Military Engineer Services - Bihar

42997759 tender for additional / alternator cum special repairs to md accommodation at mil station gaya; 2 item no 01 : m & l for vitrified ceramic tiles light shed 10 mm thick ( square or rectangular ) polished, area of each tiles not exc 0.36 sqm, in floors etc. set and jointed with cement and pointed in white or coloured cement to match over and incl 15mm thick screed bed or bedding layer with cm 1:4 complete all as specified and as directed. 3 item no 02: m & l for vitrified double charge tiles light shed 10 mm thick ( square or rectangular ) polished, area of each tiles exc 0.36 sqm but not exc 0.42 sqm each in floors etc. set and jointed with cement and pointed in white or coloured cement to match over and incl 15mm thick screed bed or bedding layer with cm 1:4 complete all as specified and as directed. 4 item no 03 : roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc.complete all as specified and as directed. 5 item no 04 : m & l for non skid ceramic coloured tiles 7 to 8 mm thick ( square / rectangular ) area of each tile exc 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and incl 15mm thick screed bed or bedding layer with cm 1:4 complete all as specified and as directed. 6 item no 05 : m & l for glazed ceramic coloured tiles in vertical surfaces 450 x 300 x 7 8 mmset and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick rendering in cement mortar 1:4on fair faces of brick work or concrete surfaces as backing for tiles including taking down old tiles complete all as specified and as directed. 7 item no 06 : dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing ) , removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. 8 item no 07 : m & l for machine cut kota stone slab flooring 20 25mm thick incl 15 mm thick cement screed base in cement mortar 1:4laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete including dismantling of stone slab of any thickness.complete all as specified and as directed. 9 item no 08 : m & l for machine cut kota stone slab 20 25mm thick incl 10 mm thick rendering in cement mortar 1:4laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete asin riser of steps, skirting, dado and pillar laid over cement screed and jointedincluding dismantling of stone slab of any thickness.complete all as specified and as directed. 10 item no 09 : s & f in repair ( 18 / 19 mm thick ) laminated with high glossy finish sunmica 1 mm thick ( colour approved by engr in charge ) all sides excluding hinge side, including 5 mm wooden leaping bead ( at hinge side ) for cupboard, kitchen cabinet shutters etc complete all as specified and directed. 11 item no 10 : s & f stainless steel slip on soft closing concealed hinges for cabinet doors, smooth oprating hinges for full overlay doors and windows complete all as specified and directed. 12 item no 11 : m & l for factory made 35 mm thick flush shutters, solid core construction, with block board core and 5 mm thick plywood face panels on both side, commercial type on both sides covered face veneered decorative type etc.complete all as specified and as directed. 13 item no 12 : m & l for pressed steel door frame size 105 mm x 60 mm made of 1.25 mm thick sheet including necessary fixing lugs, hinges, lock strike plate etc., complete, all as specified. 14 item no 13 : m & l for pressed steel door frame size 125 mm x 60 mm made of 1.25 mm thick sheet including necessary fixing lugs, hinges, lock strike plate etc., complete, all as specified. 15 item no 14 : m&l for providing pcc 1:2:4, type b 0 ( using 12.5 mm graded stone aggregate ) as in filling of pressed steel door frame and holdfasts including necessary formwork etc. 16 item no 15 : s&f in stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.18mm and fixed with beeding / staples directed by engr in charge. 17 item no 16 : s&f 4mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares of any size n. exc 0.50 sqm each complete all as specified and directed by engr in charge. 18 item no 17 : s&f 4mm thickfigured glass pin head type and glazing with oil putty or wooden beads in squares n exc 0.50 sqm each pane complete all as specified and directed. 19 item no 18 : s&f in repair 20 25 mm bore cut to length as required aluminium anodised decorative curtain rails with brackets and decorative finails as selected and directed by engr in charge. 20 item no 19 : s&f in repair 600mmx450mm bevelled edge mirror of selected quality glass, 5 mm thick mounted on pvc sheet with aluminium framingfixed to wooden plugs with chromium plated screws with dome screw caps and cup washers fixed in repairs complete all as specified and as directed. 21 item no 20 : s&f in repair 15 mm dia bore bib taps, cast copper alloy chromium plated fancy type with crutch alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed.complete all as specified and as directed. 22 item no 21 : s&f in repair 15 mm dia stop valves / angle valve, cast copper alloy, fancy type chromium plated with long shank and cup ( concealed type ) screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed. 23 item no 22 : s&f in repair pvc connections 15mm size with ptmt nuts of length 600 mm all as specified and as directed. complete all as specified and as directed. 24 item no 23 : s&f cp health faucet 15 mm with flexible tube of stainless steel provided rubber hose and wall hook etccomplete as in repair all as specified and as directedcomplete all as specified and as directed. 25 item no 24 : s& f pvc ( swr ) nahani ntrap / floor trap 75 mm dia with and including cp grating all as specified and as directed complete all as specified and as directed. 26 item no 25 : s&f in repair 25 mm dia ball valves high pressure of ptmt with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed complete all as specified and as directed. 27 item no 26 : s&f in repair 15 mm dia two way angle valves / bib taps, cast copper alloy, fancy type chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed. 28 item no 27 : supply & fix in repair brass chromium plated mixer for wash hand basin for mixing hot and cold water screwed down for iron pipes suitable for 15mm bore pipe complete all as specified and directed by engr in charge. 29 item no 28 : supply & fix in repair brass chromium plated wall mixer ( 2 / 3 hole ) with provision for connection to shower rose for mixing hot and cold water screwed down for iron pipes suitable for 15mm bore pipe complete all as specified and directed by engr in charge. 30 item no 29 : s &f as in repair chromium plated shower rose 125 mm dia with 300mm cp shower arm fancy type fixed to 15mm bore pipeall as specified and directed by engr in charge. 31 item no 30 : s & fbrass chromium plated tublar towel rail 20 mm dia d type 600mm long between flanges with cp screws etc complete all as spd 32 item no 31 : s & f in repair gun metal gate valves, with iron wheel head, screwed both ends for iron pipe flange ends type fixed of 25mm dia all as spd and directed 33 item no 32 : s&f pvc waste pipe size 32 mm x 800 mm flexible with coupling for urinal / whb / sink etc. complete all as specified and directed. 34 item no. 33 : blank 35 item no 34 : s & f male brass threaded adaptor ( mta / mbta / female brass threaded adaptor ( fta / fbta ) 20 mm dia complete all as specified. 36 item no 35 : s & f supplying and laying of cpvc pipes 20 mm outer dia sdr 11 & plain cpvc sdr 11 fittings on walls / ceiling or laying in floors complete all as specified and directed by engr in charge. 37 item no 36 : s & f supplying and laying of cpvc pipes 25 mm outer dia sdr 11 & plain cpvc sdr 11 fittings on walls / ceiling or laying in floors complete all as specified and directed by engr in charge. 38 item no 36a : s & f supplying and laying of cpvc pipes 32 mm outer dia sdr 11 & plain cpvc sdr 11 fittings on walls / ceiling or laying in floors complete all as specified and directed by engr in charge. 39 item no 36b : cleaning reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, complete all as specified and directed by engr in charge. ( bars above 12 mm diameter ) . 40 item no 36c : providing & applying two coats of anti corrosive protective coating ( cbri / csir technology ) for reinforcement bars by brush. sprinkle dry sand when second coat is tacky so as to get rough surface complete all as specified and directed. 41 item no 36d : providing, mixing and applying sbr polymer ( of approved make ) modified cement mortar in proportion of 1:4 ( 1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used ) as per specifications and directions of engineer in charge.note: the pre measurement of thickness shall be done just after the surface preparation is completed and payment under ths item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated sounding / tapping with a blunt metal instruent and / or the 75 mm size cube crushing strength at the end of 28 days to be not less than 30 n / sqmm2 ) . ( 25 mm average thickness in 2 layers ) . 42 item no 37 : taking up or down steel tubing of 15 mm dia and connections, including cleaning for re fixing or removal to store 43 item no 38 : taking up or down steel tubing of 20mm dia and connections, including cleaning for re fixing or removal to store 44 item no 39 : s & f in repair rotational three layer moulded polyethylene water storage tanks ( cylinderical vertical with closed top ) capacity 1000 ltrhoisted and fixed in position all as specified and directed by engr in charge. 45 item no 40 : demolition of brick work or stone / boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. 46 item no 41 : m&l brick work using old size bricks with fly ash bricks straightor curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and directed. 47 item no 42 :taking down cement plaster any description on brick or stone walls or wall tiles etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. 48 item no 43 :m&l for rendering 10mm thick internal surfaces on fair faces of brick work in cm 1:6 as directed by engr in charge. 49 item no 44 :m&l for rendering 15mm thick external surfaces on brick / concrete in cm 1:4 finished even and fair without using extra cement with wpc 2% by wt of cement.note: wpc measured and paid separatly 50 item no 44a :m&l for rendering 10mm thick in cm 1:3 on fair faces of brick or concrete surface of ceiling finished even and smooth without using extra cement complete all as specified and directed. 51 item no 44b :m&l for two coats of distemper with acrylic distemper in newly plastered ceiling care in two layers and making the surfaces smooth & uniform including removing existing treatment complete all as specified and directed. 52 item no 44c :m&l for two coats of weather proof external acrylic emulsion paint on projected portion to wall over on external surfaces of old plastered / concrete complete all as specified and directed. 53 item no 45 :m & l for preparation of newly plastered surfaces ofwall & concrete and applying 2mm thick wall care putty including preparation complete. 54 item no 46 :m & l for preparation of oldsurfaces ofwall & concrete and applying 2mm thick wall care putty including removal of existing treated surface. complete all as specified and as directed. 55 item no 47 :m&l for applying two coat of acrylic distemper over a coat of primer inclu preparation of newplastered wall surfaes complete all as specified and as directed. 56 item no 48 :m&l for applying two coat of acrylic distempe as in ceiling incl removal of existing treatment of old treated ceiling surfaces complete all as specified and as directed. 57 item no 49 :m&l for 2 coatsweather proof external acrylic emultion paint over a coat of primerincluding preparation of newly plastered complete all as specified and directed 58 item no 50 :demolition of concrete in ground floors and pavings including floor tiles n exc 15 cm thickness ( below or above ground level ) complete all as specified and as directed. 59 item no 51 :m & l for cement concrete type b 0, 1:2:4 ( 12.5 mm graded aggregate ) , 25 mm thick in flooring etc complete all specified and as directed 60 item no 52 :m & l for 75 mm thick cement concrete type c 1, 1:3:6 ( 20mm graded aggregate ) as in sub base complete all as specified and as directed. 61 item no 53 :m&l for granite ( any type ) work ( table rubbed and polished ) 18 to 20 mm thick in working platform and like including cutting for sink etc. in cement mortar ( 1:4 ) including rounding of edges and pointing in white cement ( 1:2 ) using marble dust with admixture of pigment to match.complete all as specified. 62 item no 54 :m & l two coats of synthetic enamel painting on steel surfaces exc 10 cm width or girth over one coat of red oxide primer including preparation of new steel surfaces. 63 item no 55 :m & l two coats of synthetic enamel painting on wooden surfaces exc 10 cm width or girthover one coat of pink primer. 64 item no 56 :m & l for tmt reinforcement bars 8 mm dia & over cut to length, bent to shape required, including crancking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire ( annealed ) not less than 0.9 mm dia or securing with clips complete 65 item no 57 :m&l rcc type b 1, 1:2:4 ( using 20 mm graded stone aggregate ) in slabs, cantilever or supported on walls and small works like cubes etc.complete all as specified and as directed. 66 item no 57 a :demolition of cement concrete ( reinforced ) n ground floor and paving n exc 150 mm thick ( below or above ground level ) complete all as specified and as directed. ( reinforcement cut as required to facilitate demolition ) . 67 item no 58 :m&l for pvc ( swr ) pipessingle socketed, in any length with rubber ring joints, laid in trenches or in floors or walls of 110 mm bore of pipe etc complete all as specified and directed. 68 item no 59 :m&l for pvc ( swr ) pipessingle socketed, in any length with rubber ring joints, laid in trenches or in floors or walls of 75 mm bore of pipe etc complete all as specified and directed 69 item no 60 :demolition and breaking up drain pipes upto 100 mm dia ( salt glazed ware, ac or reinforced concrete ) set in cement mortar complete all as specified and as directed. 70 item no 61 :s&f pvc ( swr ) bends isi marked any radius of 110 mm borewithaccess door complete all as specified and directed. 71 item no 62 :s&f pvc ( swr ) bends isi marked any radius of 75 mm borewithaccess door complete all as specified and directed. 72 item no 63 :s&f pvc ( swr ) junction single, ( single t ) equal or un equal of 110 mm bore of pipe with access door complete all as specified and directed 73 item no 64 :s & f of pvc ( swr ) vent cowl for 110 mm bore pipe complete all as specified and as directed. 74 item no 65 :s&f aluminium handles cast type anodised handles, d shape of size 150mm complete. isi marked 75 item no 66 :s & f as in repairalluminum alloy, anodised, cast type or extruded section, sliding door bolt with hasp & staple ( bolt type ) with fixing clips and bolts and 250 mm long complete all as specified. 76 item no 66 a :s & f as in repairalluminum alloy, anodised, cast type or extruded section, sliding door bolt with hasp & staple ( bolt type ) with fixing clips and bolts and 300 mm long complete all as specified. 77 item no 67 :s & f in repair sinks made of stainless steel 1.00mm thick with waste coupling with all necessary fittings, kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and as directed. 78 item no 68 :s & f in repair vitreous china wash basin oval shape white flat back size 550 x 400mm with waste coupling with all necessary fittings, chain & plug and porcelain stopper but including brackets or fixed to walls with anchor fastnersall as specified and directed by engr in charge. 79 item no 68 a :s & f vitreous china wash basin oval type of size 560 x 400 x 205 mm counter top and supply of waste pipe and cp waste coupling 32 mm dia completeall as specified and directed. 80 item no 69 :s & f of vitreous china wash down water closet pan ( pedestal pattern ) , white including fixing bolts, but excuding flushing cistern and flush pipe complete. complete all as specified and as directed. 81 item no 69 a :s & f of vitreous china wash down water closet of cascade nxt wall hung of size 670x365x770mm ( including cover ) including flushing cistern & seat cover including all required fitting complete all as specified and as directed. 82 item no 70 :s & f as in repair10 litre pvc valveless, syphonic action type, dual type flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete. 83 item no 71 :s & f as in repair soft closing white seat cover forewc incl accessories complete all as spd 84 item no 72 :m & l for repair of sunken slab as under : ( a ) m & l for application of 1:3 cement – sand mortar, mixed with sika latex emulsion ( 300 gram in 1 kg cement ) , as a coving at the corners of floor and the vertical surface in the sunken area and between floor and walls in the remaining area. ( b ) m & l for application of sika top seal 109hi @ 2.20 kg per sqm each coat or as per manufacture instruction– acrylic based, ready to use, cementitious, water proof coating onto the prepared surface in a continuous film on the floor of the sunken area, taking the coating over the vertical surfaces on to the floor and over the coving on to the wall ( before tiling ) to at least 300mm above the final finished floor level. the coating shall also be continued on to the inner surfaces of the pipe penetration holes. two coats shall be applied & fiber glass cloth to be laid in between coats. ( c ) m & l for application of sikagard 694 f ( i ) @ 100 gram per sqm or as per manufacture instruction, a moisture insensitive epoxy putty in a continuous, 10mm thick gasket around the pipes to a width of approximately 15mm. ( d ) m & l for application of protective screed concrete at a desired thickness admixed with sika cim pink @ 100 gram per sqm or as per manufacturer instruction 85 item no 73 :s & f stainless steel but hinges, medium weight cold rolled of size 100 mm . 86 item no 74 :s & f 150 mm long aluminium anodised barrel tower boltof extruded section 87 item no 75 :s & f 200 mm long aluminium anodised barrel tower boltof extruded section 88 item no 76 :taking down chowkhats or frames not exc 1.5 sqm ( without taking shutters from the frame ) . 89 item no 77 :taking down chowkhats for frames exc 1.5 sqm but n exc 4.00 sqm ( without taking shutters from the frame ) . 90 item no 78 :s & f 35 mm thick 2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc ( without sash bars ) edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc fitted to chowkhats for doors etc complete. 91 item no 79 :s & f solid pvc door frame of size 50mm x 47mm made out of 5mm single side prelam pvc sheet & edges will be painted to match with prelam sheet reinforced with m.s. square tube, suppling & fixing in opening as per specification & drawing complete all as specified and as directed. 92 item no 80 :s & f solid pvc factory madedoor shutter of 30mm ( style ) consisting of frame made out of ms tubes for top bottom rails ms frame shall be covered with heat moulded plain coloured pvc c channel having a pvc sheet strip 20mm width stuck inside with solvent cement for stilesa and plain coloured pvc sheets for top rail, lock & bottom rail on either sides & as gap insert for top rail & bottom rail panelling ofplain colour pvc sheet to be fitted in the ms frame welded / sealed to the stiles & rails with suitable pvc sheet beeding and jointed together with solvent cement as pere specification and drawing complete all as specified and as directed. 93 item no 81 :m&l for providing water proofing treatment over cleaned roof surfaces with super thermo app modified water froofing membran comprssing of following for non approachable roof: ( i ) removal of existing roof treatment and cleaning sweeping and washing and down with water to remove all dust etc from plastred roof surfaces / wall and filling of crack with sealing compound etc. ( ii ) bitumen based primer conforming to is 3384 1965 at 0.30 kg per sqm. ( iii ) one layer of super thermo app modified water proofing membran with non polyster reinforcement of make ( m / s stp texsa ltd / hyperplus membrane of m / s iwl india ltd. m / s stp and tikki tar ltd ) 3mm thick and minimum weight @ 3.50 kg / sqm laid with gas torch and fasted on roof surfaces with roller. the over laps shall be sealed by flame including vertical surfaces after cutting necessary grooving and making good with pcc gola 1:2:4 type b1 etc adhere to bitumen all as per manufacturer instructions. ( iv ) applying two coat of aluminium paint @ 0.20 kg / sqm per coat over bitumen layers as per manufacturer instruction ( application including side lap overlaps shall be provided not less than 10cm and jointed sealed with torch as per manufacturer instruction specification. 94 item no 81 a :m & l for machine cut and polished cement concrete tile factory made with grey cement without pigment of size 250 mm x 250 mm x 22 / 20 mm thick laid in neat cement slurry over and including 20 mm thick screed bed in cm 1:4 mixed chemical compound as per manufacturer instructions and tile properly laid with 3 mm wide joint filled with chemical like tile grout as per manufacturer instructions complete all as specified and directed. 95 item no 82 :supply only liquid water proofing compound isi marked. 96 item no 83 :m & l for machine pressed precast conctete interlocking paver block any shape and size confirming to is 15658 2006 of 60 mm thickness m 35 grade with grey cement and no pigment complete all as specified and directed. 97 item no 84 :sand filling under floors for cushioning ofincluding watering and consolidation 98 item no 85 :s&f mild steel framed works such as grills, gratings, etc, with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work for portions framed and hung as gates, including pintle hinges, stops, hand made sliding bolts, etc conforming to fe 290 gde e 165. 99 item no 86 :m & l for providing, cement concrete type b1, 1:2:4 ( using 20 mm graded stone aggregate ) in cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary form work all as specified and as directed 100 item no 87 :m & l formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick for rough finished flat surfaces ( horizontal or sloping ) all as specified and as directed 101 item no 88 : s & f of supply and fixing factory made upvc white colour three track three panels sliding window with fly proof s.s wire mesh ( two nos. glazed & one no. wire mesh panels ) upto 1.50m height made of ( big series ) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. ( area of window above 1.75 sqm ) comprising of upvc multi chambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length ( shape & sizeaccording to upvc profile ) , appropriate dimension of upvc extruded glazing beads and upvc extruded interlocks, epdm gasket, wool pile, zinc alloy ( white powder coated ) touch locks with hook, zinc alloy body with single nylon rollers ( weight bearing capacity to be 40 kg ) , g.i fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed by engineer in charge. ( glass or wiremesh shall be paid separately ) note: for upvc frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 102 item no 89 : supply and fixing factory made upvc white colour fixed glazed window / ventilator made of ( small series ) frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension ( area upto 0.75 sqm. ) comprising of upvc multi chambered frame and mullion ( where ever required ) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length ( shape & size according to upvc profile ) , upvc extruded glazing beads of appropriate dimension, epdm gasket, g.i. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. profile of frame shall be mitred cut and fusion welded at all corners, mullion ( if required ) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of engineer in charge. ( glass shall be paid separately ) . note: for upvc frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.complete all as specified and as directed. 103 item no 90 : s & f powder coated aluminium frame / shutters for windows, ventilators sliding / openable etc icluding joining cleat for fixing, locking arrangement, rubber beading, screws, etc complete all as specified. note : ( i ) glazing and wire mesh shall be measured and paid separetely only as the labour element included in the relavent item. ( ii ) item shall be paid as per weight of aluminium section ( iii ) the rate quoted shall be inclusive of the cost of neoprene beading, glazing pin, screws and powder coated fittings such as locking arraangement etc as required, which shall not be measured for arriving the weight ( iv ) the rate shall also be inclusive of complete packing with silicon gel around contacting surfaces of aluminium work, and including matching the existing. note: aluminium windowchowkhat and shutters are to be made as per td / issued by hq chief engineer jabalpur zone. 104 item no 91 : dismantling wrought iron or mild steel work of any description such as mild steel window / ventilator complete all as specified and as directed. 105 item no. 92 : taking down copper / aluminium point wiring ( light, fan, bell, socket or power ) complete includingfittings etc. romoving meterials to store for keeping i safe custody or for taking credit ( credit a for above items should be made as per condition seperately ) and making good distrubed surfaces of walls, floors etc complete all as specified and directed at site by engineer in charge. 106 item no. 93 : taking down old / unserviceable distribution board by disconnection of electric connection carefully spn dbs / tpn dbs / main switch including old unserviceable mccbs / mcbs, isolators, etc and making good to disturbed surface complete all as specified and directed by engineer in charge. 107 item no. 94 : taking down carefully copper / aluminium sub main wiring of any size from surface / concealed / existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed. 108 item no. 95 : taking down existing geyser of any capacity after disconnecting all necessary electrical and water supply connections and deposit to mes store yard of age e / m no ii complete all as specified and directed. 109 item no. 96 : taking down ceiling fan / exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan blsdes and deposit to mes store yard of age e / m complete all as specified and directed. 110 item no. 97 : taking down existing single phase electric energy meter of any capacity after disconnecting all necessary electrical connections and deposit to mes store yard of age e / m complete all as specified and directed. 111 item no. 98 : m&l for point wiring with 1.5 sq mm single core pvc insulated unsheathed frlsh cable multi stranded copper conductor cable in and including concealed rigid non metallic pvc conduit heavy duty grade of size 20 / 25mm isi marked inclusive of tees, bend, elbows etc upto and including sunk in anodized pressed steel box for housing switch socket etc with white laminated 3 mm thick hylam sheet cover isi marked of suitable size complete including pvc insulated multi stranded copper conductor 1.5 sq mm frlsh cable as earth wire to common earth dolly for connection to ceiling rose to earth terminal including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed by engineer in charge: 112 ( a ) one light point controlled by one, one way switch 5 amps 113 ( b ) one fan point / exhaust fan point controlled by one, one way switch 5 amps and regulator 114 ( c ) one light point controlled by one, two 2 way switches 5 amps 115 ( d ) one 3 pin 5 amps switch socket outlet point controlled by one switch on the same board. 116 ( e ) one 3 pin 5 amps switch socket outlet point controlled by one switch on the independent board 117 ( f ) one bell point controlled by one, bell switch 5 amps 118 item no. 99 : all as per item no 98 here in before but with 2.50 sq mm single core copper of multistranded frlsh pvc insulated un sheathed 1100 volts grade for 5 / 15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor frlsh pvc wire as earth continuity conductor along with wiring and connecting to the common earth dolly. 119 item no. 100 : m&l for point wiring using approved colour coding as per is, with multistranded copper conductor1.5 sqmm ( nominal area ) , two single core pvc insulated and unsheathed frlsh cable 1100 volts grade isi 694 marked drawn through in and including heavy duty pvc concealed conduit of white / ivory colour including all accessories after chasing in wall / ceiling etc, heavy duty isi marked, with gi sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable size for modular switches, including pvc insulated multistranded copper conductor 1.5 sqmm ( nominal area ) single core frlsh cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for following: 120 ( a ) one light point controlled by one, one way switch 5 amps 121 ( b ) one fan point / exhaust fan point controlled by one, one way switch 5 amps and regulator 122 ( c ) one light point controlled by one, two way switches 5 amps 123 ( d ) one 3 point 5 amps switch socket outlet point controlled by one switch on the same board. 124 ( e ) one 3 pin 5 amps switch socket outlet point controlled by one switch on the independent board 125 ( f ) one bell point controlled by one, bell switch 5 amps 126 item no. 101 : description all as per item no 100 here in before but using 2.50 sq mm single core copper conductor cable of multistranded frlsh pvc insulated un sheathed 1100 volts grade for 5 / 15 amps switch socket combination point including necessary running of 2.5 sq mm copper conductor frlsh pvc wire as earth continuity conductor along with wiring and connecting to the common earth dolly. 127 item no. 102 : description all as per item no 100 here in before but using 4.0 sq mm single core copper conductor frls cable of multistranded pvc insulated un sheathed 1100 volts grade for 5 / 15 amps switch socket cobmination point including necessary running of 4.0 sq mm copper conductor frls cable as earth continuity conductor along with wiring and connecting to the common earth dolly. ( for ac ) 128 item no. 103 : s&f switch piano flush type single pole, 5 amp, 230 volts complete all as specified and directed. 129 item no. 104 : s&f switch piano flush type single pole, 15 amp, 230 volts complete all as specified and directed. 130 item no. 105 : s&f switch piano flush type 2 way switch 5 amp, 230 volts complete all as specified and directed. 131 item no. 106 : s&f switch bell push piano type 5 amp, 230 volts complete all as specified and directed. 132 item no. 107 : s&f socket outlet 2 in 1, 5pin, 5amp, 230 volts complete all as specified and directed. 133 item no. 108 : s&f socket outlet 2 in 1, 5pin, 5 / 15amp, 230 volts complete all as specified and directed. 134 item no. 109 : supply and fixing ceiling rose surface bakelite 3 terminals, isi marked for batten fitting complete all as specified. 135 item no. 110 : s&f stepped type electronic fan regulator flush type complete all as specified and directed by engineer in charge. 136 item no. 111 : s&f for moduler switch piano flush type single pole, one way and 5 / 6 amp single module complete all as specified and directed. 137 item no. 112 : s&f for moduler switch piano flush type single pole, one way and 15 / 16 amp single module complete all as specified and directed. 138 item no. 113 : s&f for moduler switch piano flush type single pole, two way and 5 / 6 amp single module complete all as specified and directed. 139 item no. 114 : s&f for moduler socket outlet multipurpose having provision for 3 pin, 5 / 6 amp and 2 pin, 5 / 6 amp, 2 module piano flush type complete all as specified and directed. 140 item no. 115 : s&f for moduler socket outlet multipurpose having provision for 3 pin, 15 / 16 amp and 3 pin, 5 / 6 amp, 2 module piano flush type complete all as specified and directed. 141 item no. 116 : s&f for module step type fan regulator 120 watt 2 module suitable for 230 volt 50 hz ac supply complete all as specified and directed. 142 item no. 117 : s&f for bell push modular 6 amps single module complete all as specified. 143 item no. 118 : supply and fixing lamp holder pcv / polycarbonate type with back plate suitable for batten / slating fitting complete all as specified and directed by engineer in charge. 144 item no. 119 : s&f for bell electric ding dong type suitable for operation on 230 volt 50 hz ac supply complete all as specified and directed by engineer in charge. 145 item no. 120 : s&f for modular type tv socket out letcomplete all as specified and directed. 146 item no. 121 : m&l for sub main wiring with approved colour coding as per is with four single core pvc insulated frlsh cable with stranded copper conductor of 6 sq mm nominal area and drawing into suitable size of pvc non metallic rigid heavy duty pvc conduit of white / ivory colour and its accessaries isi marked heavy duty of suitable size including concealed in wall etc one run of conductor frlsh cable with 6.0 sqmm ( nominal area ) stranded copper conductor frlsh cable as earth wire complete all as specified and as directed. note: four runs of 6 sqmm cable for phase and neutral and one run of 6 sqmm cable for earthing and one run of pvc conduit will be measured as one unit. 147 item no. 122 : m&l for sub main wiring with approved colour coding as per is with two single core pvc insulated frlsh cable with stranded copper conductor of 6 sqmm nominal area and drawing into suitable size of pvc non metallic rigid heavy duty pvc conduit of white / ivory colour and its accessaries isi marked heavy duty of suitable size including concealed in wall etc one run of pvc insulated with 6.0 sqmm ( nominal area ) stranded copper conductor frlsh cable as earth wire complete all as specified and as directed. note: two runs of 6 sqmm cable for phase and neutral and one run of 6 sqmm cable for earthing and one run of pvc conduit will be measured as one unit. 148 item no. 123 : supply and fixing for sheet metal enclosure mcbdb tpn 4 way vertical type with 200amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the dbs in wall by cutting the brick / stone masonary etc and making good of distributed surface to match with existing colour of wall complete all as specified and as direced. 149 item no. 124 : supply and fixing for sheet metal enclosure mcbdb spn 8 way with 200 amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the dbs in wall by cutting the brick / stone masonary etc and making good of distributed surface to match with existing colour of wall complete all as specified and as direced. 150 item no. 125 : supply and fixing for mcb tripple pole and neutral rated capacity 63 amps 415 volts breaking capacity 10 ka, c curve complete all as specified and as direced. 151 item no. 126 : supply and fixing for mcb tripple pole and neutral rated capacity 32 amps 240 volts breaking capacity 10 ka, c curve complete all as specified and as direced. 152 item no. 127 : supply and fixing for mcb single pole rated capacity 5 to 32 amps 240 volts breaking capacity 10 ka, c curve complete all as specified and as direced. 153 item no. 128 : supply and fixing for metal clad box suitable for 230 volts 50 hz ac supply three pin with mcb sp 20 / 32 ampsremoval of old unserviceable one complete all as specified and as direced. 154 item no. 129 : s&f for water heater storage type ( geyser ) vertical / horizental type as per site requirement with inner container of capacity 25 ltrs, electrically operated, ac 230 volts, bee 5 star rated with all accesseries such as safety valve, thermostate, nrv, isi marked including 04 nos of hold fashner nuts required suitable size fixed in brick wall, including 02 no steel braided pipe 450 mm length pvc connection pipe hot & cold for officers jcos and or accn complete all as specified and as directed. 155 item no. 130 : s & f ceiling fans complete with blades, down rods, and accessories, 230 v, 1200 mm sweep. min air adelivery 210 cfm with service value 6.0 bee. five star rated with brushless direct current motor ( bldc ) complete all as specified and as directed. 156 item no. 131 : labour only for refixing the ceiling fan / exhaust fan obtained from dismantling with replacement of unsv 3 core pvc insulated pvc sheated 3 core multistranded copper conductor cable of size 23 / 0.193 from ceiling rose to fan terminal including over hauling the fan, painting of ceiling fans complete two coats synthetic enamel paint by spraying including filling cavities with filler after cleaning all dust etc. complete all as specified and as directed. 157 item no. 132 : s & f for highly efficient led bulbs 10 w with luminous efficacy not less than 105 lm / watt, used as a ready replacement for existing old gls / cfl direct fit lamp, in b 22 cap of complete all asspecified and directed. 158 item no. 133 : s&f for decorative wall mounted luminaire made out of polycarbonate with unbreakable globe suitable for led bulb and provision of led bulb 10 w with luminous efficacy not less than 105 lm / watt, complete all as specified and as directed. 159 item no. 134 : s&f for led 10 watts batten luminous efficacy having not less than 120 lm / watt aluminium extruded with decorative end caps complete all as specified and as directed. 160 item no. 135 : s & f energy saving new generation 10 watts led, luminous efficacy having not less than 110 lm / watt bulk head fitting ip 65 luminaire with opel diffuser pre wired, with warranty option of 5 years from date of installation and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23 / 0.193 form ceiling rose to fitting including led bulb complete all as specified and directed. 161 item no. 136 : s & f for wall mounted led tube light fitting 20 watts led luminous efficacy having not less than 120 lm / watt batten for surface mounted, anodized extrded aluminium housing, high transmissitivity diffuser, high lumen output box type fitting, 230 volts and intregated electronic driver connector block etc with warranty option of years from date of installation complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23 / 0.193 from ceiling rose to fitting complete all as specified and as directed. 162 item no. 137 : s & f for energy saving new generation environmental friendly long life versatile presure die cast aluminium ip 66 for security light fitting luminaire with high power leds as light source and electronic driver of capacity 25 watts, luminous efficacy having not less than 110 lumen / watt with pre wired and necessary mounting arrangements andprovision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia gi pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by engineer in charge. 163 item no. 138 : s&f for energy effcient exhaust fan of 230 mm sweep made of metal body ventil air ds type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of pvc flexible copper cable of size 23 / 0.0076 two core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for fan base complete all as specified and directed. ( note: cost of suitable opening wall for fixing exhaust fan is deemed to be included in overall rate quoted ) . 164 item no. 139 : s&f for pvc non metallic rigid conduit isi marked heavy duty white / ivory colour and its accessories heavy duty isi marked of size 20 mm dia for lan, telephone and tv connections including cutting chases and making good disturbed surfaces to match with existing finish with plaster complete all as specified and directed. 165 item no. 140 : supply, installation, commissioning and testing indoor type lt wall mounting panel board of minimum size 1.50m ( height ) x 1.20 m ( breath ) x 0.30 m ( depth ) factory made cpri approved panel, weather, dust & vermin proof indoor, double door, front openable, including four comparment for fixing of four nos three phase kwh meter, one no single phase meter and mcb tpn and providing glass view for reading of meter and providing rubber / pvc gasket of suitable size all sides of door, with copper strip / wire busbar of suitable size to mccb input and mccb / mcb output of suitable length for connection of cable from main busbar, made out of 2.00 mm thick mild steel crca sheet with suitable size angle iron supporting frame including applying two coats of powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfaces suitable for 3 phase 4 wire system 415 / 440 volts grade including complete internal wiring with 10 sqmm copper wire and connections of all outgoing / incomming existing cable of any size complete all as specified and directed by engineer in charge. ( for officers g+1 md accn ) incomming ( a ) copper strip busbar of size 30 x 5 mm wrapped with pvc sleeves with maintained the colour code and provision of making holes with copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends = 04 nos 166 ( b ) mccb ip 44 and ip 66 / 67 protection, 4 pole, 415 volts, lcu=25 ka breaking capacity, rating 100 amps, adjustable thermal magnetic release including all fixing accessories with both ends spreader links 01 no ( c ) digital voltmeter of range ( 0 500 ) volts, flush mounting type of size 100mm x 100mm ( 4x4 ) square dial with selector switch 01 no. ( d ) led neon indicator lamp ( ryb ) with holder, 230 / 250 volts, ac 01 set ( set of three ) outgoing ( a ) mcb, tripple pole & neutral, 40 amps, 415 volts, c curve, 10 ka complete all as specified and directed 4 nos ( officers accn ) ( b ) mcb, single pole & neutral, 10 amps, 240 volts, c curve, 10 ka complete all as specified and directed 4 nos ( stair case lighting ) ( c ) fixing only serviceable existing electric meter 01 no ( obtained from demolition / dismantling ) 167 ( d ) supply and fixing of three phase electronic energy meter accuracy class 1.0, 240v, with in home display 10 60a, 3 nos self locking meter seal, lcd display with with optical part, anti temper features, lcd test, serial no. date, rtc, cumulative kwh, last bill kwh, instranteous load, last bill md, instantaneous kw, volts, pf, hz, md, total tamper count, self billing code, battery backup in absence of power for display active energy kwh, including all incoming and out going connections 04 nos 168 item no. 141 : supply, installation, commissioning and testing indoor type lt wall mounting panel board of minimum size 1.20m ( height ) x 1.20 m ( breath ) x 0.30 m ( depth ) factory made cpri approved panel, weather, dust & vermin proof indoor, double door, front openable, including four comparment for fixing of five nos single phase meterand mcb and providing glass view for reading of meter and providing rubber / pvc gasket of suitable size all sides of door, with copper copper busbar wrapped with pvc tape / sleeves with maintained the colour code and copper strip / wire busbar of suitable size to mccb input and mccb / mcb output of suitable length for connection of cable from main busbar, made out of 2.00 mm thick mild steel crca sheet with suitable size angle iron supporting frame including applying two coats of powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfaces suitable for 3 phase 4 wire system 415 / 440 volts grade including complete internal wiring with 1.5 sqmm copper wire and connections of all outgoing / incomming existing cable of any size complete all as specified and directed by engineer in charge. ( for : g+1 jco, or, md accn ) incomming ( a ) copper strip busbar of size 25 x 5 mm wrapped with pvc sleeves with maintained the colour code and provision of making holes with copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends = 04 nos 169 ( b ) mccb ip 44 and ip 66 / 67 protection, 4 pole, 415 volts, lcu=25 ka breaking capacity, rating 63 amps, adjustable thermal magnetic release including all fixing accessories with both ends spreader links 01 no ( c ) digital voltmeter of range ( 0 500 ) volts, flush mounting type of size 100mm x 100mm ( 4x4 ) square dial with selector switch 01 no. ( d ) led neon indicator lamp ( ryb ) with holder, 230 / 250 volts, ac 01 set ( set of three ) outgoing ( a ) mcb, single pole & neutral, 40 amps, 240 volts, c curve, 10 ka complete all as specified and directed 6 nos ( b ) fixing only serviceable existing electric meter 05 no ( obtained from demolition / dismantling ) 170 item no. 142 : taking down existing old extg unserviceable lt under ground / service cable of any description and sizecomplete all as specified and directed. 171 item no. 143 : supply and lay cable xlpe insulated screened pvc bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty ) 1100 volts grade with stranded aluminium conductor of following sizescomplete all as specified and directed 172 ( a ) 3.5 core x 35 sqmm 173 ( b ) 4 core x 16 sqmm 174 item no.144 : excavation in trenches n exc 1.5m wide n exc 1.5m in depth for foundation etc. for laying pipe lines and cablesand getting out as in soft / loose soil complete all as specified and directed. 175 item no. 145 : returning filling in, including spreading, levelling, watering and ramming in layers not exc 25cm in soft / loose soil complete all as specified and directed. 176 item no.146 : removing excavated material to a distance not exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed. 177 item no.147 : supply and laying river bed fine sand in trenches / ducts 8 cm under cable and 15 cm above the cable for cushioning / protection to cable including spreading, levelling and get thick 18 cm after hand punning complete all as specified and directed at site. 178 item no 148 : supply and laying for brick of common burnt clay, sub class b old size laid flat and dry on cables as in cable protection in trenches over cables perpendicular to direction of cales abutting each other complete all as specified and directed. 179 item no. 149 : m&l for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6mm thick buried directly in ground ( earth pit not less than 2.25 m deep below ground level ) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to gi earth wire 4mm dia by means of bolts, nuts, washers of galvanized iron or steel all as shown in electrical plate no 3 and testing on completionincluding adequate charcoal dust comman salt necessary excavation earth work pcc ( 1:3:6 ) type c 1 pit with precast rcc cover slab 40 mm thick in pcc ( 1:2:4 ) type b 1 reinforced with 6 mm dia ms bars @ 100 mm c / c both ways with funnel wire funel wire mesh and 20 mm dia gi pipe medium grade as watering pipe and connected to earthing point complete all as specified and directed. 180 item no 150 : galvanised iron steel tubes, isi marked light grade of size 40mm bore for cable protection along the poles under road under drains complete all as specified and as directed. 181 schedule a ( schedule of credit ) schedule of credit rs 784007.00 ( minus ) inserted by the mes. ( note : credit amount shall be deducted manually to arrive net bid amount ) ...

East Central Railway - Bihar

42927650 supply of stainless steel tissue paper holder,stainless steel tissue paper holder,,stainless steel tissue paper holder, dimensions: back plate length 130 mm, back plate width 3 0 mm, back plate thickness 3 mm, back plate hole 4 mm counter sunk, tissue paper rod solid 10 mm dia., s.s grade aisi 304, as per drawing no. cd/bbs 319007 enclosed. nb sample inspection is required by the c onsignee before bulk supply. firm should submit gc/wc along with test certificate. make: jtew or similar. [ w arranty period: 30 months after the date of delivery ]...

Eastern Railways - Bihar

42523132 procurement of doorway cross bar pressing with back plate and packing piece in assembled condition etc., doorway cross bar pressing with back plate and packing piece in assembled condition to rdsos drg. no. wd 80007 s 05, item no. 2, 14 & 15. alt no. 30. [ warranty period: 30 months after the date of delivery ] ...

Eastern Railways - Bihar

42516104 supply of door way cross bardoor way cross bar,door way cross bar pressing with back plate and packing piece in assembled condition for boxn wagon as per rdso drg. no. wd 08007 s 05,item 2,14 & 15, alt 29. as per drg.no. drg no.wd 08007 s 05,item 2,14 & 15 alt 29 [ warranty period: 30 months after the date of delivery ]...

Military Engineer Services - Bihar

40135204 tender for special repair to bldg no p 86 at ota gaya; 1 demolition of cement concrete ( unreinforced ) in ground floors and pavings n exc 15 cm thickness ( below or above ground level ) . 2 demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. 3 taking down cement plaster on brick or stone walls etc, including racking out joints, hacking for key, scrubbing down with water etc. 4 dismantling floor, hearth or wall tilling including cement mortar bedding , removing serviceable tiles to store and rubbish off the premises. 5 taking down chowkat or frame with shutter ( without taking off shutters from the frames ) areaexceeding 1.5 sq mtr but not exceeding 4 sq mtr each 6 taking down chowkhats or frames not exc. 1.5 sq. m each but with shutters ( without taking off shutters from the frames ) . 7 dismantling water tanks of capacity exc 500 & not exc 1000 litres and removing to store. 8 taking up or down 15mm dia bore steel tubing and connections, including cleaning for refixing or removal to store. 9 taking up or down 20mm dia bore steel tubing and connections, including cleaning for refixing or removal to store. 10 dismantling of asbestos cement ( corrugated, semicorrugated, etc. ) sheets in roof coverings complete. 11 dismantling wrought iron or mild steel work of any description not otherwise provided for complete. 12 taking down eaves gutters and rainwater pipes ( any size or pattern ) , including all fittings, heads, shoes, bends, swan necks, etc., including cleaning or refixing or removal to store ( measured overall as fixed along the centre line over fittings and accessories ) 13 m & l for providing 75 mm thick pcc type c 1, 1 : 3 : 6, ( using 40 mm graded aggregate ) as sub base flooringand finishing surfaces even and smooth without using extra cement complete. 14 m & l for providing 50 mm thick pcc type c 2, 1 : 3 : 6, ( using 40 mm graded aggregate ) as inplinth protection and drain bed complete all as specified and directed. 15 m & l for providing precast cement concrete 1:2:4 type b 1 using 20mm graded stone aggregate as in landings, cover slabs ( for man holes etc ) and similar work including necessary formwork and set in cement mortar 1:6complete all as specified and directed. 16 m&l for brick work using sub class b old bricks straightor curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed. 17 m&l for brick work using sub class b old bricks ( except bricks ) straightor curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed. 18 m & l for 10 mm thick rendering in cement mortar 1:6 on fair faces of brick work or concrete surfaces and finishing the surface even and smoth without using extra cement complete all as specified and directed. note : chicken wire mesh be provided to the joints of column and beams during rendering. 19 m & l for rendering 15mm thick in two layerson external surfaces on brick / concrete surfaces in cm 1:4 finished even and smooth without using extra cement with wpc. note : wpc measured and paid separatly andchicken wire mesh be provided to the joints of column and beams during rendering. 20 m & l for rendering 10mm thick internal surfaces on fair faces of brick or concrete surfaces in cement plaster 1:3 as in ceiling and finished even and smooth ( without using extra cement ) complete. 21 supply only liquid water proofing compound ( make : sika latex power ) 22 cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with finishing with cement mortar 1:3. 23 m & l for non skid ceramic coloured tiles 7 to 8 mm thick ( square / rectangular ) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in cm 1:4 complete all as specified and directed. 24 m & l for coloured glazed ceramic tiles in vertical surface 450x300x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10 mm thick screed bed in cm 1:3 complete all as specified and directed. 25 m & l for machine pressed chequered cement concrete tiles 30cm x 30cm x 30mm thick with grey cement and pigment over 20 mm thick screed bed in cement mortar 1:4 complete all as specified and directed. 26 m & l for machine pressed precast concrete interlocking paver block any shape and size confirming to is 15658 2006 of 60 mm thickness, m 35 grade with grey cement and pigment complete all as specified and directed. 27 sand filling under floors for cushioning including watering and consolidation complete all as specified and directed. 28 m & l for 25mm thick cement concrete type b 0, 1:2:4using 12.50mm graded stone aggregate as in levelling course complete all as specified and directed. 29 m & l for providing pcc type b1, 1 : 2 : 4, ( using 20 mm graded aggregate ) as incoping, and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed. 30 s & f rolled mild steel in joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. ( cut to ordinary lengths i.e. within 20mm of the length indicated ) confirming to fe 410 w ( gde e 250 ) quality a complete. 31 s & f pre painted galvatume aluminum zinc coating gi based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 mpa as in roof covering / cladding to wall, fixed with self tapping screws as specified. 32 s & f solid pvc frame of size 50 mm x 47 mm made out of 5 mm single side prelam pvc sheet & edges will be printed to match with prelam sheet rein forced with ms square tube etc. 33 s & f factory made solid panel pvc door shutter 30mm ( style ) consisting of frame made out of m.s tubes for top and bottom rails m.s frame shall be covered with heat moulded plain colour pvc c channel having a pvc sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour pvc sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour pvc sheets to be fitted in the m.s frame welded / sealed to the stiles and rails with suitable pvc sheet beading and joined together with solvent cement, supplying and fixing in the frame 34 s & f powder coated aluminium section for doors, windows, ventilators sliding / openable etc with joining cleat for fixing, locking arrangement, rubber beading, screws, etc including taking down and making the surface good complete all as specified.make : jindal / hindalco / indalco. note : ( i ) glazing and wire mesh shall be measured and paid separetely. ( ii ) item shall be paid as per weight of aluminium section ( iii ) the rate quoted shall be inclusive of the cost of neoprene beading, glazing pin, screws and powder coated fittings such as locking arraangement etc as required, which shall not be measured for arriving the weight ( iv ) the rate shall also be inclusive of complete packing with silicon gel around contacting surfaces of aluminium work, and including matching the existing. 35 s & f framed work such as grills, gratings, etc.. with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to fe.290.gde e 165 complete all as specified and directed. 36 taking down existing aluminium door or window shutter with frame area exceeding 1 sqm and re fixing in same opening after repair / replace the defective jointing cleats / screws and fittings etc all as per specified and directed by engr in charge. 37 s&f 100 mm long stainless steel butt hinges with steel hinge pin etc. 38 s&f 150 mm long aluminium anodised, barrel tower bolts of extruded section and 12 mm dia fixed. 39 s&f 150mm long aluminium anodised handle cast type and fixed d type 40 s&f250mm long aluminium alloy, anodised, sliding door bolt with hasp, staple ( bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixedcomplete all as specified. 41 s&f white colour rotational three layer moulded polyethylene water storage tanks ( cylinderical vertical with closed top ) capacity 1000 ltrhoisted and fixed in position all as specified and directed. make; sintex / rotex / polycon 42 s & f in repair 25mm dia bore ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed. 43 s & f in repair 25mm dia bore cpvc gate valves with handle or wheel head, screwed both ends for pipe and fixed. 44 s & f in repair 20mm dia bore cpvc gate valves with handle or wheel head, screwed both ends for pipe and fixed. 45 supplying and laying of cpvc pipes 25mm outer dia sdr 11 & plain cpvc sdr 11 including all fittings on walls / ceilings or in floors including necessary cutting / chasing of walls and floors complete all as specified and directed. 46 s & f 25mm bore male brass threaded adaptor ( mta / mbta ) or female brass threaded adaptor ( fta / fbta ) complete. 47 supplying and laying of cpvc pipes 20mm outer dia sdr 11 & plain cpvc sdr 11 including all fittings on walls / ceilings or in floors including necessary cutting / chasing of walls and floors complete all as specified and directed. 48 s & f 20mm bore male brass threaded adaptor ( mta / mbta ) or female brass threaded adaptor ( fta / fbta ) complete. 49 s & f 110mm bore pvc ( swr ) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors and connecting with manholes or disposal place. 50 s & f 110mm dia borepvc ( swr ) bends with access door all as specified and as directed. 51 s & f of pvc ( swr ) junction single, ( single t ) 110 mm bore equal or unequal with acess door complete. 52 s & f 110mm bore pvc ( swr ) vent cowl with rubber ring joints, fixed to pipes all as specified. 53 s & f 75mm bore pvc ( swr ) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors and connecting with manholes or disposal place. 54 s & f 75mm dia borepvc ( swr ) bends with access door all as specified and as directed. 55 s & f of pvc ( swr ) junction single, ( single t ) 75 mm bore equal or unequal with acess door complete. 56 s & f as in repair of vitreous china squatting pan, ‘orissa’ pattern, size 580 x 440 mm white, with integral foot rests water closet ( squatt pattern ) complete including provision of lime concrete bedding complete all as specified and as directed make : hindware / parryware / cera 57 s & f in repair 10 litre capacity pvc valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete. 58 s & f in repair vitreous china wash basin, white, flat back of size 550x400mmexcluding taps, waste, chain and plug and porcelain stopper but including brackets, cutting for and pinning in ends of brackets or erecting stand and inclusive of fixing of supply and waste pipe and 32mm dia chromium plated waste fittings with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed. ( make parryware / hindware / jaquar ) 59 s & f pvc connections 15mm size with ptmt nuts of length 600mm complete. 60 s & f in repair 6mm thick looking mirror of 1st quality glass, mounted on 6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete. ( saint gobain / modifloat ) 61 s & f in repair 15 mm dia bore fancy type chromium plated bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed. 62 s & f in repair 15 mm dia bore fancy type chromium plated two way bib taps, cast copper alloy with crutch or butterfly handle screwed down, high pressure, screwed both ends for iron pipe or for unions. 63 s & f in repair 15 mm dia bore fancy type chromium plated stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed. 64 supply & fix in repair brass chromium plated pillar tap swan neck long body fancy typefor wash hand basin for mixing hot and cold water screwed down for iron pipes suitable for 15mm bore pipe complete. 65 s & f in repair brass / chromium plated tubular towel rail, 20mm dia, d type, 60cm long between flanges complete. 66 s & f in repair soap dish, any type, fixed to plugs with chromium plated brass screws complete. 67 s & f in repair 125mm dia stainless steel grating ( double q ) fixed on floor trap / nahani trap in cement mortar 1:6, all as specified and directed. 68 supply & fix in repair brass chromium plated wall mixer ( 2 / 3 hole ) with provision for connection to shower rose for mixing hot and cold water screwed down for iron pipes suitable for 15mm bore pipe complete all as specified and directed. ( make parryware / prayag / hindware ) 69 s & f in repair chromium plated shower rose 15 mm size, 125mm long with 300 mm arms including fixing to pipe or union complete. ( make : jaguar / parryware / hindware ) 70 s & f in repair harrison rails ofbore 20 25mm , mild steel, chromium plated cut to length as required and fixing with brackets, stops, rollers, finiales etc complete all as specified and directed. 71 m & l for 2 mm thick of birlawhite putty / jk white wall care putty in two coats on new / old plastered surfaces and making the surface uniform & smooth on walls / ceilings. 72 m & l for preparing new plastered wall surfaces and distempering two coats on walls with distemper oil emulsion, white or tinted over a coat of chalk whiting complete all as specified and directed. 73 m & l for preparing new plastered ceiling surfaces and distempering two coats on ceilings with distemper oil emulsion, white or tinted over a coat of chalk whiting complete all as specified and directed. 74 m & l for preparation of old plasteredsurfaces and applying one coat of acrylic distemper on walls complete all as specified and as directed. 75 m & l for preparation of old plasteredsurfaces and applying one coat of acrylic distemper in ceilings complete all as specified and as directed. 76 m & l for one coat of exterior emulsion paint white or tinted on walls of fascia of roof or chajjas on old decorated prepared plastered / painted surfaces of bldg all as specified and directed. make : asian paints ( brand ace ) / berger paint ( brand walmasta ) / nerolac paint ( suraksha plus ) . 77 m & l for two coats of exterior emulsion paint white or tinted over a coat of primer on walls of fascia of roof or chajjas on new prepared plastered surfaces of bldg all as specified and directed. make : asian paints ( brand ace ) / berger paint ( brand walmasta ) / nerolac paint ( suraksha plus ) . 78 m & l for one coat of exterior weather proof emulsion paint tinted on walls of fascia of roof or chajjas on old painted surfaces brick, stone, concrete, asbestos cement or plaster on old decorated prepared plastered / painted surfaces of bldg all as specified and directed. make : asian paints ( apex ) / berger paint ( brand weathercoat smooth ) / nerolac paint ( nerolac ) . 79 m & l two coat of syntetic enamel paint overnewsteel surface of any description over 10cm in width or grithnot otherwise describedover one coat red oxide primerincl preparation of surfaces complete. 80 s&f 4mm thick sheet glass, ordinary quality and glazing with oil putty in a square n exc 0.5 sq m in each pane. 81 s & f of 4.00 mm thick figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete. 82 s & fstainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40mm and fixed with beeding / staples complete all as specified and directed. 83 m&l for providing water proofing treatment over cleaned roof surface with super thermo app modified polymeric membrane comprising of followings : ( i ) . complete removal of existing roof treatment by picking, sweeping clean and washing down with water to remove dust etc from plastered / roof surface / walls and filling the crackes with sealing compound grade a . ( ii ) rendering / screed bed 15 mm thick in cement mortor ( 1:4 ) mixed with liquid water proofing compound as per manufacturers instructions andfinished the surface fair and even. ( iii ) applying evenly a coat of bitumen based primer conforming to is 3384 1965 @ 0.30 kg / sqm. ( iv ) applying 3 mm thick app modified polymeric membrane with non polyster reinforcement of approved make, weight not less than 3.50 kg / sqm laid with gas torch and fastedon roof surface with roller. the over laps 100mm and shall be sealed by torch application as per manufacture instructions including vertical surfaces after cutting necessary grooving and making good with pcc 1:2:4 type b o with sika latex power as per manufacture instructions. ( v ) applying two coats of bituminous anticorrosive multi purposealuminium coating ( super silver shield ) @ 150 gm / sqm per coat over polymeric membrene. note : wpc shall be measured and paid separately. 84 m&l for conventional rcc septic tank designed to carry sewage and sullage water, excavation in any type of soil, pcc 1:4:8 below foundation, rcc m 30 design mix in walls, base slab, baffle walls and roof slab including beams etc with vent shaft, manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 50 users. 85 soakage wells exc, in ordinary soil, foundation in pcc 1:3:6 wells of honey combed and solid in m 25 concrete , incl interlocking chamber, screen chamber brick work in cm, rcc cover slab in m 25 / rr masonary / filling with brick bats, complete of size 2.4 dia x 3.00 m deep. 86 taking down copper / aluminium point wiring ( light, fan, bell, socketor power ) complete including fixture and fittings such as switches, ceiling roses, pendent, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit ( credit a for above items should be made as per condition seperately ) and making good distrubed surfaces ofwalls, floors etc complete all as specified and directed at site. 87 taking down old / unserviceable distribution board by disconnection of electric connection carefully spn dbs / tpn dbs / main switch including old unserviceable mccbs / mcbs, isolators, etc and making good to disturbed surface complete all as specified and directed. 88 taking down carefully copper / aluminium sub main wiring of any size fromsurface / concealed / existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed. 89 taking down ceiling fan / exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan bladesand deposit to mes store yard of age e / m complete all as specified and as directed. 90 m&l for point wiring with 1.5 sq mm single core pvc insulated unsheathed copper frls multi stranded conductor cable in andincluding concealed pvc conduit of size 20 / 25mm isi marked inclusive oftees, bend, elbows etc upto and including sunk in anodized pressed steel box for housing switch socket etc withwhite laminated 3 mm thick hylam sheet cover isi marked of suitable size complete including pvc insulated multi strandedcopper conductor 1.5 sq mm frls cable as earth wire to common earth dolly for connection to ceiling rose to earth terminalincludingcutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed by engr in charge for following : 91 ( a ) one light point controlled by one, one way switch 5 amps 92 ( b ) one fan point / exhaust fan point controlled by one, one way switch 5 amps and regulator 93 ( c ) one 3 point 5 amps switch socket outlet point controlled by one switch on the same board. 94 ( d ) one 3 pin 5 amps switch socket outlet point controlled by one switch on independent board. 95 description all as per item no 90 here in before butusing 2.5 sq mm single core copper conductor cable of multistranded flame retardant pvc insulated unsheathed 1100 volts grade for 5 / 15 amps switch socket cobmination point including necessary running of2.5 sq mm copper conductor flame retardant pvc wire as earth continuity conductor along with wiring and connecting to the common eath dolly. 96 s & f switch piano type single pole 5 amp, 230 volts complete all as specified and directed. 97 s & f switch piano type single pole 15 amp, 230 volts complete all as specified and directed. 98 s & f socket outlet 2 in 1, 5 pin, 5 amp, 230 volts complete all as specified and directed. 99 s & f socket outlet 2 in 1, 5 pin, 5 / 15 amp, 230 volts complete all as specified and directed. 100 s & f ceiling rose, surface bakelite with 3 terminals, isimarked for batten fitting complete. 101 s & f stepped type electronic fan regulator flushtype complete all as specified and directed. 102 s & f lamp holder, pvc / polycarbonate type with back plate suitabl for batten / slanting fittings complete all as specified and directed. 103 m & l for sub main wiring with approved colour coding as per is with two single core pvc insulated frls cable with stranded copper conductor of size 6 sq mm nominal area and drawing into suitable size of pvc non metallic rigid heavy duty pvc conduit of white / ivory colour and its accessaries isi marked heavy duty of suitable sizeincluding concealed in wall etcone run of pvc insulated with 6.0 sqmm ( nominal area ) stranded copper conductor frls cable as earth wire complete all as specified and as directed. note: two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of pvc conduit will be measured as one unit 104 s & f for sheet metal enclosure mcb db tpn 4 way vertical type with 200 amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the dbs in wall by cutting the brick / stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. 105 s & f for sheet metal enclosure mcb db spn 8 way with 200 amps rated bus bar 240 volts double door with magnetic locking system including necessary provision for inserting the dbs in wall by cutting the brick / stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. 106 s & f formcb tripple pole and neutral rated capacity 63 amps, 415 volts breaking capacity 10 ka, c curve complete all as specified and as directed. 107 s & f for mcb single pole and neutral rated capacity 32 amps, 240 volts breaking capacity 10 ka, c curve complete all as specified and as directed. 108 s & ffor mcb single pole rated capacity 5 to 32 amps, 240 volts breaking capacity 10 ka, c curve complete all as specified and as directed. 109 s & f for ceiling fan, 230 volts, 1200 mm sweep with service value of the fan shall be greater than 6.1 as per bis with necessary accessories and electrical connections from ceiling rose to fan teriminal complete all as specified and as directed. 110 s & f for highly efficient led bulbs, 10 w, used as a ready replacement for existing gls / cfl direct fit lamp, in b 22 cap of make bajaj, havells, hpl complete all as specified and directed 111 s & f forled 10 watts batten aluminium extruded with decorative end caps complete all as specified and as directed. make bajaj cat part no bclsb 10 nw or its equivallent model in wipro, philips. 112 s & f for wall mounted led tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouputboxtype fitting, 230 volts and intregrated electronic driverconnector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired andnecessary mounting arrangements, provision of new 3 core multistrandedcopper conductor of size 23 / 0.193 from ceiling rose to fitting complete all as specified and as directed. 113 s & f building security lightfitting 1 x 35 / 36 w led new generation energy saving & environmental friendly long life led street / bldg security light made up of pressure die cast aluminium housing with mid power led as lighting source and pc cover having top opening including driver compartment driver with ip66 protection and impact resistance of ik07 including with suitable for 32mm dia medium grade g i bracket not exc 1.5 mtr length made to shape & fixing on pole / wall with 2 nos of ms clamp including necessary connection from lt oh line / buildings 114 s & f for energy efficient exhaust fan of 230 mm sweep made of metal body ventil air ds type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of pvc flexible copper cable of size 23 / 0.0076 two core from ceiling rose to exhaust fan forconnection and making suitable size ofhole to existing brick wall for fan basecompelte all as specifiedand directed. ( note : cost of suitable opening wall for fixing exhaust fan is deemed to be includedin overall rate quoted ) . 115 taking down existing old extg unserviceable lt ug / service cable of any description and sizecomplete all as specified and directed. 116 supply & laying in trenches / laid in floor / duct / drawn through conduitxlpe insulated, armoured, heavy duty elecric cable with alluminium conductor, 1100 volt grade cross sectional area 25 sqmm 4 core. 117 excavation in trenches not exceeding 1.5 mtrs wide & not exceeding 1.5 mtr in depth in soft or loose soil & getting out complete all as per & directed. 118 returning filling including spreading levelling watering & well ramming in layers not exc 25 cm 119 removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as directed. 120 m & l for laying of hdpe double wall corrugated pipes in trench for ug cable protection conforming to is 14930 part ii with ip 67 having outer dia 50 mm and inner dia of 38 mm including necessary fittings such as couplers, bends etc complete all as specified and directed. make: rex / rudrax polymers / finolex 121 m & l for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically ( earth pit not less than 2.25m deep below ground level ) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to gi earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia. medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, pcc chamber, ci frame and cover, ms funnel with wire mesh all as shown in electrical plate no 3 of ssr part i including excavation and earthwork in any type ofsoil / strata and testing on completion. note: gi earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted....

Military Engineer Services - Bihar

39115466 tender for repair / maintenance of geyser at af station bihta ; 1 material and labour for taking down of electric water heater/geyser from wall of capacity 25/50ltrs, dismantling/opening the same, servicing, cleaning and replacement of wornout, ms nuts, bolts, washers, clamps etc and making the same fully functional, re assembling, connecting and testing, complete all as specified and as directed. (note: replacement of spare parts shall be measured and paid separately). 2 material and labour for replacement of the following items required in repairs incorporated against items no 1.00 abovecomplete all as specified and as directed. (a)elect water heater element 2/1.5kw as per existing size and specification. 3 (b) apparatus (syphon assembly) plate as per existing size and specification, complete all as specified and as directed. 4 (c)thermostate switch 30 70ºc ranging.as per existing size and specification, complete all as specified and as directed. 5 (d) copper vessal (inner tank) weighing 3.5kg suitable for water heater 25 ltr capacity, complete all as specified and as directed. 6 (e) stainless steel vessal (inner tank) suitable for 25 ltrs capacity water heater, complete all as specified and as directed. 7 (f)copper vesal (inner tank) weighing 4.5kg suitable for 50ltrs capacity water heater, complete all as specified and as directed. 8 (g) stainless steel vessal (inner tank) heavy duty suitable for 50ltrs capacity water heater, complete all as specified and as directed. 9 (h) indicator lamp neon type 230volts and all as per sample, complete all as specified and as directed. 10 m&l for non return valves cast copper alloy isi mark 15 mm diaincluding taking out the old one, complete all as specified and as directed. 11 m&l pressure release valve of brass, inner threaded of 15 mm diaor as per sample approved by eicincluding taking out the old one, complete all as specified and as directed. 12 m&l pressure release valve of brass outer threaded of 15 mm dia or as per sample approved by eic including taking out the old one, complete all as specified and as directed. 13 s & f heavy duty steel braided pvc polythene connection with 15mm dia 450mm long with cp brass nuts and pvc washer 02 nos on each end, suitable for hot water including taking out the old one, complete all as specified and directed. 14 s & f heavy duty steel braided pvc polythene connection with 15mm dia 450mm long with cp brass nuts and pvc washer 02 nos on each end, suitable for cold water including taking out the old one, complete all as specified and directed. 15 m & l pvc insulated copper conductor cable, 3 core, 40/ 0.0076,ac 1100/660 volt, including taking down u/s cable, complete all as specified and as directed. 16 m&lmetallic fastener screw 75mm long 8mm dia with bolt for hanging geyser, complete all as specified and as directed. 17 m&l painting of complete outer body of storage type geyser of capacity 25 to 50 litres with two coats of synthetic enamel paint including preparing surface and writing of mes no. with black synthetic enamel paint, complete all as specified and as directed. 18 s&f 15 mm dia gi tubing, medium grade, with all gi fittings and fixed complete to walls, ceilings and floors, complete all as specified and directed. 19 m&l for multifunction safety valve of geyser, cast copper alloy, 15 mm dia, isi marked, including taking out the old one, complete all as specified and as directed. 20 s&f in repair bib taps cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for union, 15mm dia, complete all as specified and directed. 21 s&f switch piano flush button single pole one way 15 amp, 240 volts conforming to is 3854 isi marked including taking down old one complete all as specified and as directed. 22 supply and replacement of rubber gasket flange as per site requirement for 25/50 ltr geyser including taking out the old one, complete all as specified and as directed. 23 s&f 2.50 sqmm single core pvc insulated flexible stranded copper conductor wire including taking out the old, one all as specified and as directed. 24 supply only self adhesive pvc electrical insulating tape roll (1.8cm x 6.5m x 0.125mm) for attending electric complaints, complete all as specified and as directed. 25 s & f sub main wiring using approved colour coding (phase red, neutral black, earth green) complete with two single core frls pvc insulated and unsheathed stranded copper conductor cable 6 sqmmas current carrying conductor and one run of 6.0 sqmm as earth contunity conductor, voltage rating 1100 volt ,isi marked drawn in and including concealed pvc conduit isi marked of dia not less than 25 mm and thickness 2 mm with standard accessories including taking down old one, complete all as specified and as directed. note: two run of single core frls pvc cable with one run of earth contunity conductor and conduit shall be measured as one unit. 26 s & f sub main wiring using approved colour coding (phase red, neutral black, earth green) complete with two single core frls pvc insulated and unsheathed stranded copper conductor cable 4 sqmmas current carrying conductor and one run of 4.0 sqmm as earth contunity conductor, voltage rating 1100 volt ,isi marked drawn in and including concealed pvc conduit isi marked of dia not less than 25 mm and thickness 2 mm with standard accessories including taking down old one, complete all as specified and as directed. note: two run of single core frls pvc cable with one run of earth contunity conductor and conduit shall be measured as one unit. 27 s&f mcb’s single pole, 10 ka, 6 amp to 30 amp, 240 volts and of c series with required wiring connections and lugs etc and erecting in provided enclouser/distribution board. mcbs shall be of current limiting type, isi marked conforming to is 8828 1996 including taking down old one, complete all as specified and as directed. 28 s&f electric water heater storage type steel body with copper inner trank and heating element upto 2 kw capacity 25 litre bee 5 star rated complete with all accessories such as safety valve, thermostat, nrv connection piece etc. including taking down old one, complete all as specified and as directed. 29 s&f mcb’s single pole & neutral, 10 ka, 32 amp to 40 amp, 240 volts and of c series with required wiring connections and lugs etc and erecting in provided enclouser/distribution board. mcbs shall be of current limiting type, isi marked conforming to is 8828 1996 including taking down old one, complete all as specified and as directed. 30 s&f sheet metalenclosure with socket plug top and mcbs single pole with a two pin and earth plug andsocket complete with one single pole mcb ofc series of cap 16 32 ampincluding taking out the old one complete all as specified and as directed. 31 supply and fix switch socket combination of capacity of 15/16 amps, 240 volts ac, 6 pin, including taking out old one complete all as specified and as directed. 32 supply and fix top plug of capacity 05/06 amps suitable for 240 volts ac, incl taking out old one as complete all as specified and as directed. 33 supply and fix top plug of capacity 15/16 amps suitable for 240 volts ac, incl taking out old one complete all as specified and as directed. 34 taking down old unserviceable mccb db and supply, fixing and connecting up complete mccb db tpn 4 way (vertical), double door, 415 v, ac, 50 hz, with and includingmccb32 amps 16 ka, ip 40 protection conforming to is 13032 universal mounting with copper bus bar, neutral link, earth link, earthing studs, detachable gland plates with knockouts on both sides, complete all as specified and as directed. 35 s&f lamp holder pvc/polycarbonate type with back plate suitable for batten fittings, complete all as specified and as directed. ...

Military Engineer Services - Bihar

37044332 tender for special repair to omqs / smqs at af station bihta 1 excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 m deep and getting out including forming bottom surface for laying of pipes complete all as specified and directed. 2 returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 mm thick complete all as specified and directed. 3 removal of excavated material to a distance not exc 50 meter and depositing wheredirected at a level not exceeding 1.5 m above the starting point complete all as specified and directed. 4 supplying, laying and cushioning for cable protection in trenches 8 cm deep before laying cable and 15 cm deep over the cable including well punning complete all as specified and dierected 5 m&l cement concrete 1:5:10 type e2, using 40 mm graded stone coarse aggregate in sunken floor, all as specified and directed 6 m&lreinforced cement concrete (1:2:4) type b 1, (20 mm graded aggregate) as in slab supported on walls, beam, column and in similar work, complete all as specified and directed. 7 s & f for factory made solid pvc door frame of size 50mm x 47mm made out of 5mm plain colour pvc sheet, reinforced with ms square tube fixed in opening complete as per manufacturers specifications and as directed. 8 s & f for 30 mm thick factory made solid panel pvc door shutter conferming to criteria of testing as per is : 4020, consisting of frame made out of ms tube of 19 guage thickness & size 19x19mm for stiles and 15x15mm for top & bottom rails ms frames shall have a coat of red oxide primer of approved make and shall be covered with 5mm thick heat moulded pvc `c channel of size 30x50mm forming styles and 5mm thick 75mm wide pvc sheets for top rail lock rail and bottom rail on either side and 10mm (5mmx2) thick 20mm wide cross pvc sheet as gap insert for top rail and bottom rail panelling of 5 mm thick pvc sheet to be fitted in the ms frame welded/sealed to the stiles & rail with 30 mm wide x 5 mm thick pvc sheet beading on either side and joined together with solvent cement, adhesive and an additional 5 mm thick pvc strip of 20 mm width is to be struck on the interior side of c channel using pvc solvent adhesive complete as per manufacturers specifications & drawings & all as directed. 9 s & f pressed steel frames of size 125 x 60 mm for doors with one or more rebates including necessary fixing lugs hinges lock strike plate etc complete as specified. 10 s & f pressed steel frames of size 105 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete as specified. 11 m & l for pcc 1:3:6 type c 0 using 12.5mm aggregate crushed stone aggregate as in filling back side of pressed steel door/window frames, all as specified & directed. 12 s&f glazed/wire gauged/skeleton shutter 35 mm thick out of (well kilnseasoned)2nd class hard wood (hollock) the size of rails and style as per is chemically pressure treated in factory gainst termite infestation prepared to receive wire gauge (without sash bars) edges of frame chamfered or rounded fitted with cut and mitered beads, all as specified & directed.(note : wire gauge/glazing to be measured and paid separately). 13 s&f factory made 40 mm thick plain, framed, panelled shutter (two panel) with lock rail using 2nd class hw (hollock) kiln seasoned andchemicallypressure treated the size of rail and style as per is 1003 (part i) and panel insert of 9mm thick bwp commercial facing plywood or 12mm veneered particle boards with commercial ply all as specified 14 s&f plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed in 2nd class hardwood. 15 s&f of 25 mm thick flush shutters, solid core construction, with block board core and ply wood face panels, commercial type on both sides all as specified and as directed. 16 s&f in repairs of 12 mm thick plywood, grade bwr, type bb, fixed with screws to timber frame work etc. in built in cupboard complete all as specified and as directed. 17 s&f for 100mm long mild steel butt hinges, heavy weight cold rolled mild steel, all as specified and as directed. 18 s&f for 75mm long mild steel butt hinges, heavy weight cold rolled mild steel, all as specified and as directed. 19 s&f 150 mm long aluminium anodised handles, cast type, all as specified and as directed. 20 s&f for 150 mm long aluminium, anodised, barrel tower bolts of extruded section, all as specified and as directed. 21 s&f 300 mm long aluminium alloy, anodised, sliding dooor bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy, all as specified and as directed. 22 s&f for 200 mm long aluminium, anodised, barrel tower bolts of extruded section, all as specified and as directed. 23 s&f mild steel 300 mm ordinary rat tail rod pattern springs including roller & rooler plate complete all as specified and as directed. 24 s&f floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor overall length of cover plate 140mm, all as specified and as directed. 25 s&f hasp and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws of 100 mm size, all as specified and as directed. 26 s&f in repairs of harrison rail mild steel chromium plated of 19/20mm dia for curtain rod fixed with two nos of brackets for each rail all as specified and as directed. 27 s&f mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm, all as specified and as directed. 28 s&f anodised aluminium powder coated frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified & directed. (note : minimum thickness of powder coating 50 micron). 29 s&f anodised aluminium powder coated window and ventilator shutters, hung type without sash bar, aluminium section weighing not less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. anodised aluminium fittings such as peg stays 150 mm long (01 no), hinges b 21 100 mm long (02 no), suitable handle (01 no) complete all as specified.(note : minimum thickness of powder coating 50 micron). 30 s&f sheet glass 4 mm thick ordinary quality & glazing with rubber gasket in square n.exc 0.5 sqm in each pane, all as specified and directed.. 31 s&f 3 mm thick figured glass, pinhead type in squares n.exc 0.50 sqm each pane, all as specified and directed. 32 m&lfor mild steel tmt bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete, all specified and directed. 33 s&f in repair 18mm thick celuka pvc sheet minimum 600 kg/cum density grade 1 quality of both side plain white colour rigidlam glossy finish fixed with screws, solvent cement/adhesive as per manufacturer instructions to make kitchen cabinet sides top and bottom and shelves inside the cabinet completeas per specifications and as directed. note: (i) cup board accessories ie fittings,handles,hinges, will be measured and paid under this schedule.(ii) quoted rates deem to be include fixing of cabinet on wall with appropriate rawl plug/ dash through fastener (hammer type).(iii) fabrication and installation of cabinet to be carried out by authorised vendor of manufacturer only. 34 s&f auto closing stainless steel (grade 304) hinges 35 mm of 0 crank (kh 001) or 8 crank (kh 002) openable at 110 degree for kitchen cabinet shutters all as specified & directed. 35 s&f stainless steel handles of 100 mm size for kitchen cabinet shutter complete all as specified. 36 m&l for app basedpolymeric water proofing membrane minimum weight 3 kg/ sqm and minimum 3mm thick reinforced with polyster non wove fabrick (weight not less than 150gms/sqm), laid with torched application with the strict supervision of manufacturers technical supervisor, laid over hot blown bitumen 85/25 grade @1.2 kg per sqm over bitumen primer @0.30 ltr/sqm including cleaning surface, complete all as specified and directed.(note membrane shall be laid with 100mm side/end lap on prepared surface as per manufacturer instruction work shall be carried out strictly with the technical tradesmen and supervision of technical staff of manufacturer) 37 m&l for 40 mm thick brick tiles laid on bedding of 15 mm thick cement mortar (1:6) and joints grouted flush in cement mortar (1:3) on treated roof all as specified and as directed 38 m&l for applying bituminous primer @ 0.40 kg/sqm and applying one coat of hot blown bitumen of grade 85/25 @ 1.20 kg/sqm as in sunken complete all as specified including fixing of 40 mm dia gi spout pipe at bottom of slab/plastered surface etc, all as specified & directed. 39 roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc, all as specified & directed. 40 m&l for providing cement concrete type b 1, 1:2:4 (20 mm graded aggregate) as in roof padding, roof kerbs (rounded or chamfered on edge) etc all as specified & directed. 41 m&l 75 mm thick cement concrete type d 2, 1:4:8 (using 40 mm graded aggregate) as in subbase to floor, ll as specified and directed.. 42 m&l for 25 mm thick cement concrete type b 0, 1:2:4 (12.5 mm graded aggregate) as on floor, ll as specified and directed.. 43 m & lnon skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tiles including 15 mm thick screed bed in cement mortar 1:6 all as specified and directed. 44 m & lnon skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tiles including 15 mm thick screed bed 1:6 all as specified and directed. 45 m & l glazed ceramic coloured tiles of approved quality isi marked (450 x 300 x 7 mm / 350 x 250 x 7 mmthick) as in vertical surfaces such as skirting dados etc set jointed in neat cement slurry and pointed in coloured cement to match with the tiles including 1:4 cement plaster 10 mm thick on brick work and concrete surface, all as specified and directed. 46 m&l for 15 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms (including a hole of gas pipe) and like including 15 mm thick screed bed in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, all as specified and directed. 47 rounding to edges of stone slabs one edge, such as in steps, cooking platform, and similar situations, all as specified and directed.. 48 m&l for rendering 10 mm thick in cement mortor 1:4 on fair faces of brick work, surfaces finished even and fair without using extra cementwith water proofing compound, all as specified and directed. (note : wpc shall be measured and paid seperatelly). 49 m&l for 10 mm thick rendering in cement mortor (1:6) on air faces of brick work, surfaces finished even and smooth without using extra cement cement, all as specified and directed 50 m & l for 15 mm thick rendering in cm (1:4) on vertical surfaces of brick walls finished even and smooth without using extra cement with using water proofing compound, all as specified & directed. (note wpc will be measured and paid separately). 51 m&l for 5 mm thick rendering in cm (1:3) on ceiling surfacesoffinished even and fair without using extra cement, all as specified & directed.. 52 supply only integral water proofing compound 53 s&f 15 mm gi tubes medium grade with all fitting and fixed complete to walls, ceilings or laid infloors including taking up or down old steel tube complete all as specified and directed. 54 s&f 20 mm gi tubes medium grade with all fitting and fixed complete to walls, ceilings or laid infloors including taking up or down old steel tube complete all as specified and directed. 55 m&l for preparation of new wood basesurfaces of any description, over 10 cm in width or girth, not otherwise described and appling twocoats of synthetic enamel paint (ordinary tint) overone coats of pink primer, all as specified and directed. 56 m&l peparation of old painted wooden surfaes of any dscription over 10cm width or girth and applying one coatof synthetic enamel paint complete all as specified and as directed. 57 m&l peparation of old painted steel surfaces of any description over 10cmwidth or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. 58 m&l for preparation of new plastered surfaces of ceiling and applying three coats of white wash all as specified and directed. 59 m&l for preparation of old surfaces of ceiling and applying two coats of white washall as specified and directed. 60 m&l for preparation of new plastered surfaces of wall and applying three coats of white wash all as specified and directed. 61 m&l for preparation of old decorated plasteredsurfaces of wall and applying two coat of white wash all as specified and directed. 62 m&l for preparation of new plastered surfaces of wall and applying two coats oil bound distemper over a coat of alkali resistant primer over a coat of 1 mm thick wall care putty in two different layers complete all as specified & as directed.(note treatment slall be carried our by spraying with mechanical means) 63 m&l for complete removal of existing treatment of wall and applying two coats oil bound distemper over a coat of alkali resistant primer over a coat of 1 mm thick wall care putty in two different layers complete all as specified & as directed.(note treatment slall be carried our by spraying with mechanical means) 64 m&l for complete removing of existing treatment of wall surfaces by scrapping with mechanical sander (having mechanical vacuum mechanism)to make surface clean, free from dust, loose paint etc and applying two coat of cement base paint of different colours complete all as specified and directed. 65 m&l for preparation of new plastered surfaces of walls and applying two coat of cement base paint of any colours and pattern (two or more colours) complete all as specified and directed.(note : colour and pattern of paint will be directed by ge) 66 m&l for pvc (swr) pipe of 110 mm boresingle socketed in any length with rubber ring joint fixed to wall with suitable clamps of adequate numbers etc complete all as specified and directed. 67 s&fpvc swr bends 110 mm boreall as specified and directed. 68 s&f cast iron soil, waste pipe100 mm dia, sand cast, in any length with or without ear, with cement joint, laid in trenches, complete all as specified. 69 s&f cast iron soil, wastepipe100 mm dia, sand cast, in any length with or without ear, with cement joint, laid in trenches, complete all as specified. 70 s&f cast iron soil, waste and vent pipe100 mm dia, sand cast, in any length with or without ear, with cement joint, fixed on wall, complete all as specified. 71 s&f cast iron soil, waste and vent pipe100 mm dia, sand cast, in any length with or without ear, with cement joint, fixed on wall, complete all as specified & directed. 72 s & f in repairs of 100 mm bore cast iron bends of any radius diminshing pieces or tappers (larger bore measured), all as specified & directed.. 73 s & f in repairs of 75 mm bore cast iron bends of any radius diminshing pieces or tappers (larger bore measured), all as specified & directed.. 74 s&f cast iron cowls of 100 mm bore pipe, all as specified & directed. 75 s & f in repairs cast iron floor trap with chromium plated graating of 100 mm size including jointing to waste pipe with cement joints etc, all as specified & directed. 76 s&f soap dish brass chromium plated decorative type, size 160x90mm complete all as specifed and directed. 77 s&f 600 mm x 450 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick ac buildg board or commercial plywood and fixed to wooden plugs with cpbrass screws and cup washers complete all as specified and directed. 78 s&f in repairbrass chromium plated, tubular towel rails 20 mm dia, d type, 60cm long between flanges, completed all as specified and directed. 79 s&f in repair chromium plated 125 mm size shower rose with swivel joints, in square with cp long shank arm including fixing to steel pipe or union of 15 mm bore, complete all as specified and as directed. 80 s&f in repairs vitreous china squatting pan “orissa pattern” of size 580 x 440mm white with integral foot rest (excluding flushing cistern & flush pipe) including connection to trap and to flush pipes etc and lime concrete bedding complete all as specified in ssr and including s&f trap set complete all as specified and directed. 81 s&f in repairs pvc flushing cistern 10 ltr capacity valve less syphonic action type low level with and including dual flushball valve float & handle, waste pipe & brackets complete set complete all as specified and directed. 82 s & f in repairvitreous china wash basin, flat back, size 630x450mm white, excluding waste coupling, chain & plug, ci prackets, pvc waste pipe 32 mm,and porcelain stopper but including brackets. 83 s&f in repair chromium plated fancy type, stop cock/angular cock, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends of size 15mm bore. complete all as specified and directed. 84 s&f in repair chromium plated concealed type, stop valve, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends of size 15mm bore. complete all as specified and directed. 85 s & f in repair 15mm bore chromium plated bib tap, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron or brass ferrule, complete all as specified and directed. 86 s&f sheet glass assembly consisting of 5.5mm thick sheet glass shelf 12mm wide with chromium plated bracket guard and railing, 600mm long,complete all as specified and directed. 87 s & f in repair pillar taps fancy type(long body)cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, screwed for iron pipe, complete all as specified and directed. 88 s&f in repairpvc connections 15mm size with ptmt nuts of length 450 mm, complete all as specified and as directed. 89 s&frotational moulded polythene water storage tank of capacity 500 ltrs (cylindrical/vertical with closed top), triple layer construction, isi marked, hoisted & fixed in position including followings : (i)20 mm gi pipe medium grade,over flow 450mm long.(ii) 20 mm gi pipe medium grade waste pipe 600mm long.(iii) 20 mm brass ball valve/float valves, high pressure & high density plastic ball screwed for iron pipe and fixed.(iv) 20 mm gun metal globe/gate valve with iron wheel head, screwed on both ends for fixing including one gi nipple(20mm bore). 90 s&f in repair sink with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and waste; including pvcwaste pipe, cp waste coupling,bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified anddirected. 91 s&f 1mm thick stainless steel kitchen plate rack of size 750x 900mm best quality assembled with brass washer and nut and bolts including hooks (spoon/cup holders) complete all as specified & directed. 92 demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level), all as specified & directed..note : all demolished items/ debris to be removed out side of mod land. 93 demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for, all as specified & directed..note : all demolished items/ debris to be removed out side of mod land. 94 demolition of reinforced cement concrete of any description & in any position, complete all as specified and directed. 95 dismantling of stone slabs and tiles of any description or thickness in floors aprons etc including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. 96 dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises,all as specified and directed. 97 taking down cement plaster on brick or stone walls, etc, incl raking out joints, hacking for key, scrubbing down with water, etc & prepare to receive new plaster complete all as specified and directed 98 taking down chowkats or frame with shutter (without taking out shutter from the frame) not exceeding 1.50 sqm each and removal from site all as specified and directed. 99 taking down chowkats or frame with shutter (without taking out shutter from the frame) exceeding 1.50 sqm and n exc 4.00 sqm each and removal from site all as specified and directed 100 taking down of shutters of any description exc 1.00 sqm but n. exc 2 sqm each, all as specified and directed 101 taiking up or down steel tubing and connections, 15 mm bore including cleaning, complete all as specified and directed. 102 taiking up or down steel tubing and connections, 20 mm bore including cleaning, complete all as specified and directed. 103 dismantling pvc water tankcapacity exceeding 250 but not exceeding 500 ltr, complete all as specified and directed. 104 taking down100/75 mm cast iron soil waste pipe (any size or patterns) moulding all fittings heads shoes, bends etc (measured over all as fixed along the confrece line over fittings and accessories), all as specified and directed. 105 taking down rain water pipes (any size or pattern) ,including all fittings all as specified and directted . 106 demolition of bricks (laid flat or on edge) or brick tiles in floors, channels, kerbs, aprons, etc (each layer) laid, bedded and pointed in any mortar including removal of debris/muds etc complete all as specified and as directed.note : all demolished items/ debris to be removed out side of mod land. 107 demolition of mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) and finally cleaning the surface with wire brush to remove old treatment to lay pcc padding, complete all as specified and directed..note : all demolished items/ debris to be removed out side of mod land 108 taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc, complete all as specified and directed. 109 taking down old unserviceable mcb db tpn4 way (vertical), double door, 415 v, ac, 50 hz, includingmcb63 amps 16 ka ,ip 40 protection conforming to is 13032 universal mounting with copper bus bar,neutral link, earth link, earthing studs, detachable gland plates with knockouts on both sides, complete all as specified & directed. 110 material and labour for concealed point wring for one light/fan/exhaust fan point controlled by 1 no,one way 5/6 amp switch ,using approved colour coding (phase red,neutral black,earth green) complete with frls pvc insulated and unshealthedstranded copper conductor cable 1.5 sqmm single coreconforming to is 694 including medium duty concealed unplasticised pvc conduit conforming to is 9537(part 3) and isi marked not less than 20 mm dia with concealed in wall pressed steel terminal box of not less than 2 mm thick of required size including painting terminal boxs inside and outside with two coat of synthetic enamle paint over one coat of red oxide primerwith top cover3 mm thickbakelight laminated sheetwith brass screws and cup washer with all assessories including frls pvc insulated and unshealthedstranded copper conductor cable 1.5 sqmm single core in green colouras earth wireconnected to earth dolly . complete all as specified and directed . 111 all as per item no 110 above butfor one 3 pin /5 pin socket outlet 5 amp controlled by 1 no one way 5/6 amp switch on same board along with other switches ,fan regulator etc. 112 all as per item no 110 above butfor one 3 pin /5 pin socket outlet 5 amp controlled by 1 no one way 5/6 amp switch on independent board. 113 all as per item no 110 above butfor one call bell/buzzer point controlled by one push button switch. 114 material and labour for point wring ,using approved colour coding (phase red,neutral black,earth green) complete for one socket outlet 15 amp on independent board with frls pvc insulated and unshealthedstranded copper conductor cable 2.5 sqmm single coreconforming to is 694 including medium duty concealed unplasticised pvc conduit conforming to is 9537(part 3) and isi marked not less than 20 mm dia with concealed in wall pressed steel terminal box of not less than 2 mm thick of required size including painting terminal boxs inside and outside with two coat of synthetic enamle paint over one coat of red oxide primerwith top cover3 mm thickbakelight laminated sheetwith brass screws and cup washer with all assessories including frls pvc insulated and unshealthedstranded copper conductor cable 2.5 sqmm single core in green colouras earth wireconnected to earth dolly complete all as specified and directed. 115 s&f switch piano flush button single pole one way 5/6 amp, 240 volts conforming to is 3854 isi marked all as specified and directed. 116 s&ffor socket outlet, 5 pin, 5/6 amp flush type conforming to is 1293 isi marked all as specified and directed. 117 s&f switch piano flush button single pole one way 15 amp, 240 volts conforming to is 3854 isi marked including taking down old one, all as specified and directed. 118 s&ffor socket outlet, 3 pin, 15 amp flush type conforming to is 1293 isi marked including taking down old one, all as specified and directed. 119 s&fceiling rose, surface bakelite,isolated bodythree terminals including taking down old one, all as specified and directed. 120 s&f lamp holder pvc/polycarbonate type with back plate suitable for batten fittings, all as specified and directed. 121 supply only led bulb of 09 watt complete all as specified and directed. 122 s&f forbell push flush type 5 a sp 240 v all as specified and directed. 123 s&fbell (ding dong) 230 volts, single pole all as specified and directed. 124 taking down ceiling fan including cable, dismantling blades and carry out mnr repair and fixing of damaged parts like capacitor, bushes, bearings and screws etc and keeping in safe custody of contractor up to re fixing in the same. all as specified & directed. 125 m&l for painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust, all as specified and directed. 126 hanging only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan, all as specified and directed. 127 m & l for repair / rewinding of ceiling fand replacement of requisite spares like bush, bearing, down rod, capacitor, fan clamp, fan blade etc if necessary all as specified and directed. 128 m & l for repair / rewinding of exaust fand replacement of requisite spares like bush, bearing, capacitor, fan clamp, fan blade etc if necessary all as specified and directed. 129 supply and fixing led tube lights fitting 1x 18w, 220v, including led tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling roseand complete all as specified and directed. 130 supply and fixing led batten type tube light complete fitting 1x 10 w, 220v,connecting up with three core flexible copper conductor cable of suitable size from ceiling roseand complete all as specified and directed. 131 supply &fixing and connecting up complete mcb db tpn 4 way (vertical), double door, 415 v, ac, 50 hz, with and includingmcb63 amps 16 ka ,ip 40 protection conforming to is 13032 universal mounting with copper bus bar,neutral link, earth link, earthing studs, detachable gland plates with knockouts on both sides, complete all as specified & directed. 132 s&f sheet metal enclosures (mcb distribution board) when mcb’s to be used singlepole and neutral 8 ways 220 volt with 200 amps rated bus bar, double door with bus bar neutral link earth bar, din rail, necessary blanking plated, including fixing db flush in wall complete with making good disturbed surfaces and colour matching all as specified and directed including taking down old one, complete all as specified & directed. 133 s&f mcb’s single pole, 10 ka ,32 amp to 40 amp 240 volts,and of b series with required wiring connections and lugs etc and erecting in provided enclouser/destribution board.mcbs shall be of current limiting type ,isi marked conforming to is 8828 1996, including taking down old one, complete all as specified & directed. 134 s&f sheet metalenclosure with socket plug top and mcbs single pole with a two pin and earth plug andsocket complete with one single pole mcb ofc series of cap 20 amps including taking out the old one all as specified and directed. 135 s&f mcb’s dp, 10 ka, 32 amp to 40 amp 240 volts,and of b series with required wiring connections and lugs etc and erecting in provided enclouser/destribution board. mcbs shall be of current limiting type ,isi marked conforming to is 8828 1996,including taking down old one complete all as directed. 136 supply and fixing stud 10 w led lights energy saving bulk head luminaries including led light driver, holder connecting up with three core flexible copper conductor cable of suitable size from ceiling roseand complete all as specified and directed. 137 s&f sub main wiring using approved colour coding (phase red,neutral black,earth green) complete with two single core frls pvc insulated and unsheathedstranded copper conductor cable 6 sqmmas current carrying conductor and one run of 6.0 sqmm as neutral cable ,voltage rating 1100 volt ,isi marked drawn in and including concealed pvc conduit isi marked of dia not less than 25 mm and thickness 2 mm with stranded accessories along with one run of frls pvc green colour insulated,unshealthed,stranded copper conductor of size 6 sqmm all as specified and directedincluding taking down old one, complete all as specified and directed.(note: two run of single core frls pvc cable with one run of earth contunity conductor and conduit shall be measured as one unit.) 138 m&l for earthing complete with galvanized steel earth plate 600x600x6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead wire of 4mm dia as earthing lead by means of bolts, nuts, check nuts, and washers of galvanised iron or steel besides welding at all joints as shown in drawings and including excavation and earth work, gi pipe light grade 15 mm bore for protection of giwire from earth electrodeto test point /machinery / equipment.supplying and laying charcoal dustcomman saltpcc(1:2:4) type b1 using 20 mm gradedstone agregratechamber andrcc cover 54 cm x 54cm x50 mm thick (1:2:4) type b 1using 20 mm stone agrigrtae )reinforced with 8 mm dia tmt bars @75mm c/c both ways with mild steel handle 12 mm dia,using round bar ,pgi funnel with wire mesh, 20 mm dia gi pipe medium grade for watering all as shown in electrical plate no 3 of ssr part 1including testing and taking out the old one complete all as specified and directed(note cost of gi wire and gi protection pipe up to a distance 7.5 m shall be includedin quated rate of above items) 139 s&f 415 v, 10 ka ,b curve miniature circuit breaker mcb tpn 63 amps, 16 ka complete all as specified and directed. 140 supply, laying, connecting and testing xlpe cable underground pvc insulated and over all sheathed with aluminium conductor heavy duty 1100 volts grade 3.5 core 35 sqmm sizes, laid in trenches, floors, ducts passing through pipe forroad crossing etc including taking down old unsv cable of any size complete all as directed including taking out old damaged cable and all as specified and directed. (note excavation, earth work, brick protection sand cushioningand gi pipe etc shall be measured & paid for separately) 141 m&l for laying of bricks subclass ‘b’ old size having crushing strengh not s than 75 kg/sqcm, laid flat perpendicular to the direction of cable for protection of cable complete all as specified & directed. 142 m&l gi tubing 50 mm dia light grade, laid in trench/floor or fixed on wall with all fixingaccessories etc as specified and directed. ...

Department of Defence Production - Bihar

35997455 bids are invited for micro mech pump and spares mse bare pump model no mic 32 to 160 , mechanical seal set , base frame ms , impeller solid pfa lined , back plate with pfa lined , casing with pfa lined , coupling set ms total quantity : 10...

Indian Oil Corporation Limited - Bihar

34557484 supply of fs elliot compressor spares at barauni refinery , list of item(s) / work(s) as per tender documents , rotor a1 l.s, p/n 250990 312 , rotor a1 h.s, p/n 250097 546 , brg, jour. p300,p400,a,a1, p/n dp1087 6 , shim pack,p/n:280002 gr1 , brg,thrust(inactive),p/n:p1562g9300 , brg,thrust(active),p/n:p1562g9350 , shim (brass),p/n:p835b3000 , seal oil,p/n:p7963a1450 , retaining ring, p/n p27j61 , o ring , seal housing,p/n:p700d040 , ring, retaining, p/n 280004 3 , seal carbon ring,p/n:p7963a3110 , o ring , back plate,p/n:p700d238 , o ring, p/n p700a010 , shim diffuser, p/n 270689 gr 1 , shim casing, p/n p835w152 , filter elt,primary air,p/n:p3515f200 1 , filter elt,secondary air,p/n:p3515f200 2 , filter elt,oil mist,p/n:p3515b165 1 , oil filter elt,p/n:p99v15 , main oil pump,p/n:p7210t1050 , oil cooler, p/n p2275j1080...

Department Of Science And Technology - Bihar

33967262 bids are invited for mech lab equipments ( q3 ) , milling machine is:6893 , is:8614 , is:9474 ( q2 ) total quantity : 2 1 engineering mechanics lab. equipment a screw jack apparatus with weights screw jack ( without weights)all metallic construction accurately machine cut screw with a pitch of 5 mm carrying a double fanged turn table of about 20 cm diameter. fitted on a heavy cast iron base and complete with two adjustable pulleys, cord and hooks. 02 b worm and worm wheel :: single with weights an all metallic self contained apparatus useful for demonstrating the efficiency for worm and wheel and also the principle of work. consisting of a machine cut worm gear of 25 cm diameter, carrying a meta l drum of 12 cm diameter, and machine cut worm on steel spindle carrying a 12 cm diameter pulley. 02 c worm and worm wheel :: double with weights an all metallic self contained apparatus useful for demonstrating the efficiency of worm and wheel and also the principle of works. consisting of machine cut worm gear of 25 cm diameter, carrying a metal drum on 12 cm diameter, and machine cut worm on steel spindle carrying a 12 cm diameter pulley. double weight 02 d worm and worm wheel :: tripple with weights an all metallic self contained apparatus useful for demonstrating the efficiency of worm and wheel and also the principle of work, consisting of machine cut worm gear of 25cm diameter carrying a metal drum of 12 cm diameter pulley. 02 e wheel and differential axle 30 cm with weight the axle having dia of 15 & 7.5 cm respectively giving a ratio of 1:2:4. centre of the wheel which is mounted on ball bearing in cast iron brackets reducing friction to minimum. 02 f winch crab single purchase with weight fitted with heavy cast iron wall brackets. the grooved wheel is of 25 cm diameter and gears are machine cut. this apparatus is used for experiments in efficiency of mechanical advantage weights are included. 02 g winch crab double purchase with weight there are two geared wheels; one wheel carries a big axle round which a string is wound to lift a load w. the second geared wheel (upper one) carries a pulley which a string is wound to carry the effort p. suppose the first geared wheel (with axle) has n1 teeth and the second geared wheel (with pulley) is given n revolutions the first geared wheel will take : n(n1/n2 ) 02 h universal force table (normal) for experimentally verifying the lows of triangle, parallelogram and polygon if force comprising of equal circular 40cm.dia.aluminiym disc graduated into div ,compel with levelling screws, clamping device to fix the table ,string and five sets iron nicked slotted weight. 02 i moment of inertia of flywheel 25 cm with weights. experiment on the moment of mass inertia of a flywheel. steel flywheel. steel shaft used as drive pulley. set of weights ball bearing mounted shaft. anodised aluminium base plate wall mounted. 25 cm with weights 02 j parallel forces apparatus (dial type 10 kg. balance) verification of condition of equilibrium of parallel forces, law of lever and forces on beam etc. consisting of two compression thrust type 10 kg. dial type compression balances fixed on wooden polished board, a wooden bar with steel back plate 02 2 machine drawing lab. equipment a hemispherical sectional models of screw threads whitworth, square, butteress, acme. right and left hand screw; set of all the six threads made of aluminium metal mounted on base with nomeclature 02 b hemispherical sectional models of screw threads nuts set of six sectional model of nuts, properly mounted on base with nomenclature. 02 c standard bolt diameter 25 mm, length about 15 cm. approximately. properly constructed model is of aluminium alloy, complete with whit worth nut, lock nut and washer. 02 d bolts of four types ordinary. eye type, stud type and set screw type. properly constructed and mounted on base with nomenclature. 02 e foundation bolts 02 rag bolt, cotter bolt and lewis bolt a set of three aluminium models fitted on base. f foundation bolts (with nomenclature) four different types of bolts with nomenclature mounted on base. 02 g locking arrangement of bolts check nut, castle nut. grooved nut, swan nut, stop plate nut and spring washer nut. with the help of these models actual locking systems can be demonstrated. 02 h rivetted joints wooden 02 i screw jack apparatus with weights all metallic construction accurately machine cut screw with a pitch of 5 mm carrying a double fangedturntableofabout20cmdiameter.fittedon a heavy cast iron base and complete with two adjustable pulleys, cord and hooks. with weight 02 j bush bearing 02 k plummer block or pedestal bearing 02 l foot step bearing 02 m flexible coupling 02 n flanged coupling 02 o stuffing box 02 p connecting rod 02 q spark plug 02 3 fluid machinery a reciprocating pump test rig description: the experimental unit provides the basic experiments to get to know the operating behaviour and the important characteristic variables of piston pumps. setup features a closed water circuit with water tank, a piston pump with variable speed via a frequency converter and an air vessel. the piston of the pump is mounted in a housing and can be observed during operation. the cycle that takes place (intake and discharge of water) can be shown clearly in the p v diagram. the pulsating pressure curve of the pump can be damped with the aid of the air vessel. flow rate and head are adjusted via a needle valve and overflow valve. the experimental unit is fitted with manometer for pressure and sensor for flow rate. pressure manometer measures the pressure at the outlet of the pump. specification: · functioning and operating behaviour of a piston pump · closed water circuit contains piston pump with variable speed via frequency converter, transparent water tank and air vessel ·valve for adjusting the flow rate · overflow valve for adjusting the head · pulsation damping of the head using air vessel with bleed valve ·manometer for pressure at pump outlet. technical details: piston pump speed: 30…180min 1 max. flow rate: 135l/h max. head: 40m drive motor power: 180w gear transmission ratio: i=7,5 overflow valve: 1…4bar measuring ranges pressure (outlet): 0…5bar flow rate: 0,2…6l/min experimentation: principle of operation of a piston pump recording of pump characteristics pressure curves of delivery pressure p v diagram determination of efficiencies 01 b centrifugal pump test rig ms tank with frp lining unit, centrifugal pump of size 25x25mm todischarge about 60 lpm at 12m total head when run at maximum 01 speed.motor1hpdcelectricmotorisimarkedspeedvariationthirstiercontrolled arrangement with panel board. electrical panel: dp switch, isimark & energy meter for the measurement of input power. sump tank:size : 800 x 800 x 500 mm , measuring tank : size 400x400x600mmprovided with standard fittings for measuring discharge of water. digitalstop watch, others: piping system consisting of pipes, gate valve (isimark) & fittings with pressure gauge,a standard pump of 1 hp, allaccessories and spares for normal running maintenance of the machine (1set), 2 hard copies of operation manual willbe supplied along with theset up c hydraulic bench the hydraulic bench should be suitable for the use of basic fluid mechanics experiments of fluid mechanics. it should supply the water in the closed circuit; the determination of volumetric flow rate and the positioning of the experimental unit on the working surface of the base module and the collection of dripping water. the closed water circuit consists of the sump tank with the submersible pump and the measuring tank arranged above, in which the returning water is collected. the measuring tank is stepped, for large and smaller volumetric flow rates. a measuring cylinder should be provided for very small volumetric flow rates. a stopwatch should also be provided for measuring the flow rate. the top surface should enable the various experimental units to be easily and safely positioned. specification 1. base module for supplying experimental units in fluid mechanics 2. closed water circuit with storage tank, submersible pump and measuring tank. 3. measuring tank divided into two for volumetric flow rate measurement. 4. measuring cylinder with scale for very small volumetric flow rates.. 5. measurement of volumetric flow rate by using a stopwatch. 6. work surface with inside edge for safe placement of the accessories and for collecting the dripping water. technical data pump power consumption:500 750 w max. flow rate:200 450l/min max. head: 7 14m storage tank, contents: 180l measuring tank at large volumetric flow rates: 40l at small volumetric flow rates: 10l measuring cylinder with scale for very small volumetric flow rates content: 2l utility required 230v, 50/60hz,1 phase 01 d air blower apparatus description: this equipment comprises of a fd centrifugal blower coupled to a motor. three interchangeable impellers with forward, backward and radial vanes are provided with the test rig. a pitot tube is provided in the delivery line of blower for static and dynamic pressure measurement. power input to the dc motor is varied by means of a thyristor controlled dc drive to vary the rpm of motor. a rpm indicator with proximity sensor indicates the rpm of blower. technical details: motor: dc motor with thyristor controlled dc drive for variable speed blower: centrifugal, forced draft type impeller (3 nos.): forward curved, backward curved & radial curved pitot tube (with manometer): for static, dynamic & differential pressure measurement. stop watch: electronic control panel comprises of : standard make on/off switch, mains indicator, etc. energy measurement: electronic energy meter. rpm measurement: digital rpm indicator with proximity sensor. instruction manual: an english instruction manual will be provided along with the apparatus. experimentation: · to study the effect of forward curved, back curved and radial curved impeller. 01 · to find out the discharge, head and efficiency of the centrifugal blower. · to plot the graph efficiency vs discharge · to plot the graph discharge vs head 4 dynamics of machinery a four bar chain mechanism 01 b slide crank mechanism set of 3 01 c slip & creep measurement apparatus the apparatus consists of a variable speed d.c. motor, driving pulley and driven pulley of equal diameter. the pulleys ore mounted on input shaft (motor shaft) and output shaft. the driven pulleys can slide on the base with bearing block to change initial tension in belt. brake drum mounted on output shaft helps to measure power output. the motor speed is varied by dimmer stat. a two channel rpm indicator is provided to measure speeds of driven and driving pullies respectively. specifications: d.c. motor:1 hp 1500 rpm, variable speed. driving & driven pullies of equal diameters. brake drum along with spring balance. flat belt of fixed length of following materials: fabric belt , rubber belt tightening arrangement, speed controller unit, two channel digital apm indicator stroboscope. range of experiment: to measure co efficient of friction between pulley material and different belt materials. to measure power transmitted with varied belt tensions and plotting graph of (t1 t2). tension characteristics. to measure percentage slip at fixed belt tension by varying load on brake drum and plot graph of (t1 t2) vs percentage slip le. slip characteristics. finding a creep zone from graph. to measure belt slip speed and observe the limiting value float at constant speed when the slip just starts. 01 d cam analysis machine the apparatus is designed to study the cam profiles and performance of cam and follower system. the apparatus consists of a shaft supported by ball bearings upon which three different types of cams be mounted. the push rod for follower is supported vertically, which can adopt three different types of followers. cams and followers can be changed easily. a variable speed motor rotates the cam. a dial gauge permits plotting of follower displacement with respect to cam position. by operating the system at different speeds, jump speed can be found and also the effect of weight and spring force on jump speed can be studied. jump can be visualized also with the help of an optional stroboscope. specifications: · cam eccentric, tangent and circular arc type one each · follower mushroom, flat faced end roller type one each · cams and followers are hardened to reduce wear of the surfaces. · variable speed motor coupled to cam shaft of suitable range and variac · a dial gauge to note the follower displacement 01 e epicyclic gear train and torque holding apparatus it is a motorized unit consisting of sun gear mounted on input shaft. these planet gears are mounted on a common arm to which output shaft is fitted. loading arrangement is provided for loading the system and to measure holding torque. specifications external type epicyclic gear train: bearing blocks for input & output shafts a gear train with holding drum and holding internal typo epicyclic gear train: a compact gear train. variable speed d.c. motor rope brake arrangement to measure output torque and holding torque. control panel comprising of : digital ammeter and voltmeter. rpm indicator. speed controller. 01 f motorized gyroscope 01 the apparatus consists of a rotor mounted in bearings, this rotor is free to rotate about a. its own axis i.e. axis of spin. b. axis at precession. c. axis of gyroscopic couple the rotor is connected to the variable speed motor. the weight of the motor is balanced by another weight which is on either side of the rotor, by putting weights on the weight platform torque can be supplied to rotor, which is also called gyroscopic couple specifications: rotor diameter 250mm free about 3 axis of rotation driven by variable speed motor. dimmer stat to control the motor speed. stopwatch to measure the angular speed about the axis of procession. weights: 0.2kg, 0.5kg, 1kg. g motorized governor apparatus the unit consists of a main spindle driven by a variable speed motor. three different governor assemblies can be mounted over the spindle. pointer measures the lift of the governor. students can calculate characteristic of governor and compare their performance viz. sensitivities, stability, governor effort, etc specifications governor assemblies hartnell, porter& porpel governor assembly one each with rotating weights. variable speed fhp d.c. motor to drive the main spindle. sliding weights for porter & proell governor. scale & a pointer to measure governor lift. spring & spring compression adjustment arrangement. 01 h static & dynamic balancing apparatus. equipment is designed for carrying out the experiment for balancing 8 rotation mass systems. the apparatus consists of a stainless steel shaft fixed in a rectangular frame. a set of four blocks with a clamping arrangement is provided for static balancing. each block is individually clamped on shaft and its relative weight is found out using cord and container system in terms of number of steel bans. for dynamic balancing a moment polygon is drawn using relative weights and angular and axial position of blocks is determined. the block are clamped on shaft is rotated by a motor to check dynamic balance of the system. the system is provided with angular and longitudinal scales and is suspended with chains for dynamic balancing. experiments: 1. to balance the masses statically and dynamically of a single rotating mass system. 2. to observe the effect of unbalance in a rotating mass system. technical specification drive motor fhp motor, variable speed, with speed controller balancing weight 4 nos. of stainless steel with different sized eccentric mass for varying unbalance rotating shaft – material stainless steel 0.5 kw, 220v, single phase 01 i bar pendulum or compound pendulum 01 j rope brake dynamometer 01 k prony brake dynamometer 01 l whirling of shaft apparatus. the unit consists of a base upon which the bearing holders and driving motor and bearing can be fitted in a holders to end conditions of test shafts. a variac provides control of driving motor. the unit demonstrates the phenomenon of whirling of shafts with single rotor as the test is destructive after the test same shaft cannot be used again, hence the unit only demonstrates the principle. specifications: test shaft: 4.75 mm, 6.35 mm and 7.9 mm 2 each. bearing to provided end conditions, (a) both ends fixed, (b) one end fixed and one end free. drive motor 1/8 hp. 1500 rpm with control arrangement. the whole unit is mounted on a sturdy base. rotor for each shaft of suitable size. 01 m journal bearing test rig description: 01 the apparatus consists of a plain steel shaft excavated in a bearing and directly driven by a fhp motor. the bearing is freely supported on the shaft and sealed at the motor end. the speed of the motor is controlled by the speed control unit. manometer is mounted on bearing to measure the pressure at different position around the circumference. bearing is free to rotate and can be adjusted at any position of circular scale. the bearing can be loaded by attaching weights to the arm supported beneath it. technical details: journal : diameter 50 mm bearing : diameter 55 mm weights : 4 weights. motor : variable speed fhp motor control panel : for speed control of motor. oil recommended : sae 40 manometer : 16 tube manometer instruction manual : an english instruction manual will be provided along with the apparatus. the whole set up is well designed and arranged in a good quality painted structure. experimentation: to study the pressure profile of lubricating oil at various conditions of load and speed. plotting the cartesian polar pressure curves. 5 single cylinder four stroke petrol engine test rig the setup consists of single cylinder, four stroke, petrol engine connected to eddy current dynamometer for engine loading. the setup has stand‐alone type independent panel box consisting of air box, fuel tank, manometer, fuel measuring unit, digital speed indicator and digital temperature indicator. the setup enables study of engine for brake power, bmep, brake thermal efficiency, volumetric efficiency, specific fuel consumption, air fuel ratio and heat balance. provision is also made for conducting morse test. set up is supplied with ms excel program for engine performance analysis. self calculation and graphs sheets with excel programmings for comparison. solution tabs as reference for online diagnostics to problems. almost components from highly reputed mnc and international imports. self calibration/check techniques available specification: engine: make ‐honda, model ‐honda gx200d qx, type‐single cylinder, 4 stroke petrol, air cooled, 4.1 kw at 3600 rpm, stroke 54 mm, bore 68mm. capacity 196 cc dynamometer: type eddy current, water cooled propeller shaft: with universal joints air box: m s fabricated with orifice meter and manometer fuel tank: capacity 15 lit with glass fuel metering column rpm indicator: digital with non contact type speed sensor temperature sensor: type thermocouple, type k temperature indicator: digital, range 0‐1200 deg c load indicator: digital, range 0‐50 kg, supply 230vac load sensor: load cell, type strain gauge, range 0‐50 kg...

Military Engineer Services - Bihar

33366200 repair / maintenance of gyser at af stn bihta 1 material and labour for taking down of electric water heater / geyser from wall of capacity 25 / 50ltrs, dismantling / opening the same, servicing, cleaning and replacement of wornout, ms nut bolts, washers, clamps etc and made functional fully assembling, connected and testingcomplete all as specified and as directed. 2 material and labour for replacement of the following items required in repairs incorporated against items no19 abovecomplete all as specified and as directed. ( a ) elect water heater element 2 / 1.5kw as per existing size and specification 3 ( b ) apparatus ( syphon assembly ) plate as per existing size and specification complete all as specified and as directed. 4 ( c ) thermostate switch 30 70ºc ranging.as per existing size and specification complete all as specified and as directed. 5 ( d ) copper vessal ( inner tank ) of weighting 3.5kg suitable for water heater 25 ltr capacity complete all as specified and as directed. 6 ( e ) ss vessal ( inner tank ) suitable for 25 ltrs capacity water heater complete all as specified and as directed. 7 ( f ) copper vesal ( inner tank ) of weighting 4.5kg suitable for 50ltrs capacity water heater complete all as specified and as directed. 8 ( g ) ss vessal ( inner tank ) heavy duty suitable for 50ltrs capacity water heater complete all as specified and as directed. 9 ( h ) indicator lamp neon type 230w and all as per sample complete all as specified and as directed. 10 m&l for non return valves cast copper alloy isi mark 15 mm diaincluding taking out the old one complete all as required and complete all as specified and as directed. 11 m&l pressure release valve of brass inner threaded of 15 mm diaor as per sample approved by eicincluding taking out the old one complete all as specified and as directed. 12 m&l pressure release valve of brass outer threaded of 15 mm dia or as per sample approved by eicincluding taking out the old one complete all as specified and as directed. 13 s & f heavy duty steel bedded pvc polythene connection with 15mm dia 450mm long with cp brass nuts and leads pvc washer 02 nos on each endsfor hot waterincluding taking out the old one complete all as specified and directed. 14 s & f heavy duty steel bedded pvc polythene connection with 15mm dia 450mm long with cp brass nuts and leads pvc washer completefor cold water completeincluding taking out the old one complete all as specified and as directed. 15 m & l pvc insulated copper cable 3 core 40 / 0.0076, ac 1100 / 660 volt including taking down u / s cable complete all as specified and as directed. 16 m & lmetallic fastener screw 75mm long 6mm dia with bolt for hanging geyser, complete all as specified and as directed. 17 m&l painting of complete outer body of storage type geyser of capacity 25 to 50 litres with one coat of red oxide primer with two coat of synthetic enameled paint including preparing surface and including writing of mes no with black paint complete all as specified and as directed. 18 m&l gi tubing 15 mm dia medium gradeisi marked, laid in trench / floor or fixed on wall with all fixingaccessories etc complete all as specified and as directed. 19 m&l for multifunction safety valve cast copper alloy 15 mm dia isi markedincluding taking out the old one complete all as specified and as directed. 20 m&l forwater tapecast copper alloy 15 mm dia isi markedincluding taking out the old one complete all as specified and as directed. 21 s&f switch piano flush button single pole one way 15 amp, 240 volts conforming to is 3854 isi marked including taking down old one complete all as specified and as directed. 22 supply and replacement of rubber gasket flange as per site requirement for 25 / 50 ltr geyserincluding taking out the old one complete all as specified and as directed. 23 s & f sub main wiring using approved colour coding ( phase red, neutral black, earth green ) complete with two single core frls pvc insulated and unshealthedstranded copper conductor cable 6 sqmmas current carrying conductor and one run of 6.0 sqmm as earth contunity conductor , voltage rating 1100 volt , isi marked drawn in and including concealed pvc conduit isi marked of dia not less than 25 mm and thickness 2 mm with stranded accessories along with one run of frls pvc green colour insulated, unshealthed, stranded copper conductor of size 6 sqmm all as specified and directedincluding taking down old one complete all as specified and as directed. note: two run of single core frls pvc cable with one run of earth contunity conductor and conduit shall be measured as one unit. 24 s & f sub main wiring using approved colour coding ( phase red, neutral black, earth green ) complete with two single core frls pvc insulated and unshealthedstranded copper conductor cable 4 sqmmas current carrying conductor and one run of 4.0 sqmm as earth contunity conductor , voltage rating 1100 volt , isi marked drawn in and including concealed pvc conduit isi marked of dia not less than 25 mm and thickness 2 mm with stranded accessories along with one run of frls pvc green colour insulated, unshealthed, stranded copper conductor of size 4 sqmm all as specified and directedincluding taking down old one complete all as specified and as directed. note: two run of single core frls pvc cable with one run of earth contunity conductor and conduit shall be measured as one unit. 25 s&f mcb’s single pole, 10 ka , 6 amp to 30 amp 240 volts, and of c series with required wiring connections and lugs etc and erecting in provided enclouser / destribution board.mcbs shall be of current limiting type , isi marked conforming to is 8828 1996.the power loss per pole shall be low and shall be in accordance with is 8828 1996, all cable entries shall be either from bottom or top .mcb shall be of c curve charactertics & shall have quick make and break non welding self wiping silver alloy contact for 10 ka short circuit both on manual & automatic operation .including taking down old one complete all as specified and as directed. 26 s& f electric water heater storage type steel body with copper inner trank and heating element upto 2 kw capacity 25 litre bee 5 star rated complete with alkll accessories such as safety valve , thermostat , nrv connection piece etc. including taking down old one complete all as specified and as directed. 27 s&f mcb’s single pole and neutral, 10 ka , 32 amp to 40 amp 240 volts, and of c series with required wiring connections and lugs etc and erecting in provided enclouser / destribution board.mcbs shall be of current limiting type , isi marked conforming to is 8828 1996.the power loss per pole shall be low and shall be in accordance with is 8828 1996, all cable entries shall be either from bottom or top .mcb shall be of c curve charactertics & shall have quick make and break non welding self wiping silver alloy contact for 10 ka short circuit both on manual & automatic operation .all the active , live parts of mcbs should be out of human reach , ensuring safty & conforming to ip 55 degree of protection . including taking down old one complete all as specified and as directed. 28 s&f sheet metalenclosure with socket plug top and mcbs single pole with a two pin and earth plug andsocket complete with one single pole mcb ofc series of cap 16 32 ampincluding taking out the old one complete all as specified and as directed. 29 supply and fix switch socket combo of capacity of 15 / 16 amps with suitable make incl taking out old one complete all as specified and as directed. 30 supply and fix top plug of capacity 05 / 06 amps with suitable make incl taking out old one as complete all as specified and as directed. 31 supply and fix top plug of capacity 15 / 16 amps with suitable make incl taking out old one complete all as specified and as directed. 32 taking down old unserviceable mccb db tpn and supply, fixing and connecting up complete mccb db tpn 4 way ( vertical ) , double door, 415 v, ac, 50 hz, with and includingmccb32 amps 16 ka , ip 40 protection conforming to is 13032 universal mounting with copper bus bar, neutral link, earth link, earthing studs, detachable gland plates with knockouts on both sides complete all as specified and as directed. 33 s&f lamp holder pvc / polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed. 34 s&f street light fitting 45 watt 230 v ac outdoor type high pressure die cast aluminum housiong and heat resistant complete with driver , lamp bracket with imapoact bracket and corrosive resistant incl thermal management complete with ip 65 protection complete all as specified and as directed. 35 s&f flexible wire including taking out the old one complete all as specified and as directed....

Eastern Railways - Bihar

31967085 supply of procurement of door way cross bar etc.procurement of door way cross bar etc.,door way cross bar pressing with back plate and packing piece in assembled condition to r.d.s.os drg. no. wd 80007 s 05, item no.2,14 & 15, alt no.28 (twenty eight)....

Eastern Railways - Bihar

27672747 supply of procurement of door way cross bar pressing with back plate and packing piece in assembled condition etc.procurement of door way cross bar pressing with back plate and packing piece in assembled condition etc., door way cross bar pressing with back plate and packing piece in assembled condition to rdsos drg. no. wd 80007 s 05, item no.2, 14 & 15, alt no.25...

National Thermal Power Corporation Limited - Bihar

26169049 supply of rc feeder spares of stage 2 and 3 mill at farakka stps . , back plate of stock feeder , bushing for coal feeder , grease retainer , grease seal outer , grease seal inner , grease retainer , seal ( cam side ) for gear box , seal ( cem side ) , seal ( worm gear shaft out put end ) coc , seal ( worm gear shaft output end ) coc , bearing cover for head pulley , bushing for coal feeder , bearing retainer for head pulley , drive sprockets rc60 , f1 / cms / a301792 , driven sprockets rc60 72t 3 , stage i feeder back plate , f1cmsa302901 . , stud & nut with body nut , f1 / cmsa303047 , stud & nut , f1cmsa303045 , shear pin for 1 w9009 gear box , torque arm for coc , take up screw for take up block , worm gear shaft for feeder drive gb , pin for head pulley of stock feeder , bearing cover for head pulley , bearing housing assembly for inlet span , bearing housing for weigh span roller , bearing housing casing for weigh span , roller for bunker outlet valve , gating assembly for coal valve , bushing for coal feeder , half coupling , take up drive block , screw take up , belt takeup screw block coal feeder belt , cover plate for main drive reducer , shaft tension roll 500 mw coal feeder , chain pin; , drive shaft & sprocket assly . for coc , belt take up block of stock feeder...

Eastern Railways - Bihar

23954950 supply of , back plate bolster to rdsos drg. no.wd 01065 s 02, item no. 2 , alt no. 2....

Eastern Railways - Bihar

23150011 supply of procurement of door way cross bar., door way cross bar pressing with back plate and packing piece in assembled condition for boxn wagon as per rdso drg. no. wd 80007 s 05,item 2,14 & 15, alt 24....

Indian Railway - Bihar

17662001 tender for back plate bolster drg no.wd 01065 s 02 item no 02 alt 02 or latest...

Eastern Railways - Bihar

17109678 tender for door way cross bar pressing with back plate and packing piece in assembled condition for boxnwagon as per rdso drg. no. wd 80007 s 05,item 2,14 & 15, alt 24 or latest....

Eastern Railways - Bihar

16700016 tender for door way cross bar pressing with back plate and packing piece in assembled condition for boxnwagon as per rdsos drg. no. wd 80007 s 05,item no. 2,14 & 15, alt no. 24....