Military Engineer Services - Bihar

45089669 tender for provision of sainik institute at mil stn gaya; 2 schedule a part i (building work)lump sum price worked out by the contractor for building work as listed in schedule a part i against the lump sum price inserted by the mes. 3 sch a part ii (internal water supply)lump sum price worked out by the contractor for internal water supply) as listed in schedule a part ii against the lump sum price inserted by the mes. 4 sch a part iii(internal electric supply)lump sum price worked out by the contractor for internal electric supply as listed in schedule a part iii against the lump sum price inserted by the mes. 5 sch a part iv(external water supply)lump sum price worked out by the contractor for external water supply as listed in schedule a part iv against the lump sum price inserted by the mes. 6 sch a part v(external electrific supply)lump sum price worked out by the contractor forexternal electrific supply as listed in schedule a part v against the lump sum price inserted by the mes. 7 sch a part vi(road, path and culvert)lump sum price worked out by the contractor for road path and hard standing as listed in schedule a part vi against the lump sum price inserted by the mes. 8 sch a part vii(sewage disposal)lump sum price worked out by the contractor for sewage disposal as listed in schedule a part vii against the lump sum price inserted by the mes. 9 sch a part viii (area drainage)lump sum price worked out by the contractor for area drainage as listed in schedule a part viii against the lump sum price inserted by the mes. 10 sch a part ix(site clearance, excavation & earth works)lump sum price worked out by the contractor for site clearance, excavation & earth works as listed in schedule a part ix against the lump sum priceinserted by the mes. 11 note for srl no 2 to 10the percentage above / below the ssr 2020 (part ii) rates shall be derived from the amount quoted by the contractor against srl no. 2 to 11by comparing it with the amount inserted / pre priced by the department and the same shall be applicable for the items of respective schedule 12 schedule a part x (miscellaneous works) 13 item no 01 : supply, install, commissioning and testing of split type wall mounted air conditioner of capacity 1.5 tr (4500 k cal/hr) single phase, (non cfc/hchc) suitable for 230 volt +10%, 50 hz, ac supply complete with cordless remote control unit, minimum bee 3 star rating, eer of 5.02 and above complete all as specified and directed. 14 item no 02 : supply and fixing voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 v to 250 v with output voltage stabilized at 230 v with accuracy of ± 2.5% and of capacity 4 kva complete all as specified and directed. 15 item no 03 : supply and fix water cooler electric driven (single phase), having approx storage capacity of 80 litre and nominal cooling capacity of 40 litres per hour complete all as specified and directed. 16 sewage disposal 17 item no 04 : m&l for dwc hdpe pipes class sn 8 laid in trenches of 150 mm internal diameter of pipe and jointed as specified complete all as specified and directed. 18 item no 05 : m&l for dwc hdpe pipes class sn 8 laid in trenches of 100 mm internal diameter of pipe and jointed as specified complete all as specified and directed. 19 arboriculture 20 item no 06 : material & labour for continuous brick on deging with width equal to the depth of the brick laid dry on end at the required angle with modular bricks sub class b bricks complete all as specified and directed. note: the rate quoted by the tenderer for this item shall be inclusive of embedding bricks in the ground upto the required depth and tempering the ground around bricks and removing surplus soil to a distance not exceeding 100 m complete all as specified and directed. 21 item no 07 : supply & plant ashoka plant of height 7 complete all as specified and directed. 22 item no 08 : supply & plant cycas leaf palm of height 4 of height 7 complete all as specified and directed. 23 item no 09 : supply & plant sampen palm of height 5 of height 7 complete all as specified and directed. 24 item no 10 : supply & plant triangular palm of height 7 complete all as specified and directed. 25 item no 11 : supply & plant triangular plant of height 7 complete all as specified and directed. 26 item no 12 : supply & plant bottle palm of height 7 complete all as specified and directed. 27 item no 13 : supply & plant china palm of height 1 complete all as specified and directed. 28 item no 14 : supply & plant pichutia palm of height 4 complete all as specified and directed. 29 item no 15 : supply & plant red palm of height 6 complete all as specified and directed. 30 item no 16 : supply & plant areca palm of height 7 complete all as specified and directed. 31 item no 17 : supply & plant ficus palm of height 4 5 complete all as specified and directed. 32 item no 18 : supply & plant golden cypress plant of height 5 complete all as specified and directed. 33 item no 19 : supply & plant silver star plant of height 1 2 complete all as specified and directed. 34 item no 20 : supply & plant coconut plant of height 7 complete all as specified and directed. 35 item no 21 : supply & plant euforbia plant of height 1 complete all as specified and directed. 36 item no 22 : supply & plant supari palm of height 7 complete all as specified and directed. 37 item no 23 : supply & plant foxtail palm of height 7 complete all as specified and directed. 38 item no 24 : supply & plant green vichia palm of height 7 complete all as specified and directed. 39 item no 25 : supply & plant cantia palm of height 7 complete all as specified and directed. 40 item no 26 : supply & plant ravenea palm of height 4 complete all as specified and directed. 41 item no 27 : supply & plant rhapis palm of height 4 complete all as specified and directed. 42 internal electrical supply 43 item no 28 :m & l for point wiring using approved colour coding as per is, with multistranded copper conductor1.5 sq. mm (nominal area), single core, pvc insulated and unsheathed frlsh cable 1100 volts gradeisi 694 marked drawn through in and including heavy duty, pvc concealed conduit of white/ ivory colour including all accessories after chasing in wall/ceiling etc, heavy duty isi marked, including pvc insulated multistranded copper conductor 1.5 sqmm (nominal area) single core frlsh cable as earth continuity conductor to common earth and connecting to earth dolly includingcutting, chasses and makinggooddisturbed surface to match with existing finish with plaster complete all as specified and directed for the following : 44 (a) one light point controlled by one, one way switch 5 amps 45 (b) one fan point/ exhaust fan point controlled by one, one way switch 5 amps and regulator 46 (d) one 3 point 5 amps switch socket outlet point controlled by one switch on the same board. 47 (e)one 3 pin 5 amps switch socket outlet point controlled by one switch on independent boad. 48 item no 29 :description all as per item no 28 here in before butusing 2.5 sq mm single core copper conductor two noscables of multistranded flame retardant pvc insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of2.5 sq mm copper conductor flame retardant pvc wire as earth continuity conductor along with wiring and connecting to the common eath dolly. 49 item no 30 :description all as per item no. 28 here in before butusing 4.0 sq mm single core copper conductor two nosfrlsh cable of multistranded pvc insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of4.0 sq mm pvc insulated copper conductor frlsh cable as earth continuity conductor along with wiring and connecting to the common eath dolly. (for ac point) 50 item no 31 : s & f modular metal flush box 8 module 51 item no 32 : s & f modular metal flush box 12 module 52 item no 33 : s & f modular white cover plate with frame 12module 53 item no 34 : m & l forsub main wiring with approved colour coding as per is with two single core pvc insulated frlsh cable with stranded copper conductor of size 6 sq mm nominal area and drawing into suitable size of pvc non metallic rigid heavy duty pvc conduit of white/ ivory colour and its accessaries isi marked heavy duty of suitable sizeincluding concealed in wall etcone run of pvc insulated with 6.0 sqmm (nominal area) stranded copper conductor frlsh cable as earth wire complete all as specified and as directed. note: two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of pvc conduit will be measured as one unit 54 item no 35 : s & f for sheet metal enclosure mcbdbtpn4 way verticaltype with 200 amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the dbs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. 55 item no 36 : s & f for sheet metal enclosure mcbdbspn8 way with 200 amps rated bus bar 240 volts double door including blanking plate for dummy space with magnitic locking system including necessary provision for inserting the dbs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specifiedand as directed. 56 item no 37 : s & fformcb four polerated capacity 63 amps, 415 volts breaking capacity 10 ka, c curve complete all as specified and as directed. 57 item no 38 : s & f for mcb dp rated capacity 32amps, 240 volts breaking capacity 10 ka, c curve complete all as specified and as directed. 58 item no 39 : s & ffor mcb single pole rated capacity 6 32 amps, 240 volts breaking capacity 10 ka, c curve complete all as specified and as directed. ( 6a 15 nos, 10a 05 nos, 16a 10nos, 32a 08 nos) 59 item no 40 : s & ffor metal clad box suitable for 230 volt 50 hz ac supply with threee pin power socket & plug top 15 amp including mcb sp 25 ampcomplete all as specified and as directed complete all as specified and as directed 60 item no 41 : supply and fixing ceiling fans complete with blades, down rods, electronic regulator modular type and accessories, 230 v, 1200 mm sweep. min air delivery 210 cfm with service value 6.0 bee. five star rated with brushless direct current motor (bldc) complete all as specified and as directed. 61 item no 42 : s & f forled 10 watts batten aluminium extruded with decorative end caps with luminous efficacy not less than 120 lumen/watt complete all as specified and as directed. 62 item no 43 : s & f led luminaire surface/recess mounted type 36 watt, approx size of600mm x 600mm, 230 voltswith crca housing with and intregrated electronic driverconnector block with luminous efficacy not less than 120 lumen/watt etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired andnecessary mounting arrangements, provision of new 3 core multistrandedcopper conductor with flexible conduit of 0.75 sqm sizecomplete all as specified and as directed. 63 item no 44 : s & f for wall mounted led tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput with luminous efficacy not less than 120 lumen/wattboxtype fitting, 230 volts and intregrated electronic driverconnector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired andnecessary mounting arrangements, provision of new 3 core multistrandedcopper conductor and flexible conduit of size 0.75 sqm from ceiling rose to fitting complete all as specified and as directed. 64 item no 45 : s & f for energy saving new generation environmental friendly long life versatile presure die cast aluminium ip 66 for security light fitting luminaire with high power leds as light source and electronic driver of capacity 35 wattswith luminous efficacy not less than 110 lumen/wattwith pre wired andnecessary mounting arrangements and provision of 0.75 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia gi pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by engineer in charge. 65 item no 46 : s & f for energy efficient exhaust fan of 300 mm sweep made of metal body ventil air ds type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of pvc flexible copper cable of size 0.75 sqmm three core from ceiling rose to exhaust fan forconnection and making suitable size ofhole to existing brick wall for fan basecompelte all as specifiedand directed. 66 item no 47 : s& f occupancy sensor suspended type to detect the presence of a person for include automatic adjustment of lights systems in response to the quantity of people present for switch off/on the light in a circuit as per user reqmt ( for use at parking area, verandah or any other space where power saving srequired) 67 external electrical supply 68 item no 48 : supply, fabrication, installation and testing of lt panel out door type factory made cpri approved, water and vermin proof protection of size 1000mm x 1000mm x 500 mm (over all dimension) made out of 3.00 mm thick crca sheet dully supported with mild steel angle iron of size 50 x 50 x 6 mm vertical frame and legs with mild steel flat iron 25 x 5 mm in horizontal sides of the frame with front and back side openable, single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing pcc (1:3:6) type c2 foundation of suitable size and connections of all outgoing / incomming cable inclusive of necessary excavation and earthwork as required including the following fitment accessories complete all as specified and directed. 69 incomming(a) copper strip busbar of 100 amps rated capacity wrapped with pvc sleeves with maintained the colour code and provision of making holes with copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends 04 nos (b) tpn mcb 40 amps 01 no. (c) on load change over switch tpn of capacity 63 amps 01 no (d) led neon indicator lamp (ryb) with holder and fuse holder 230/250 volts, ac 01 set (set of three) (e) digital ammeter of range (0 100) amps, flush mounting type with ct’s of ratio 100/5 and selector switch 01 set. 70 outgoing(a) mcb tpn 32 amps 02 nos. (one spare) (b) mcb spn 16 amps 01 nos (street light) (c) enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm x 150mm, white with letters, figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter of jb for lt 01 no. 71 item no 49 : s&f pvc junction box of size 350mm x 250mmm x 138mm outdoor type, weather proof, factory made out of pvc sheet 1.8mm thick with front side hinged opening having locking arrangement with nuts & bolts & arrangement for incoming and outgoing cable/wire complete comprising of aluminium bus bar for 3 phases & neutral, insulated with insulators, including colour coding and 01 nos mcb 06 amps complete all as specified and directed. 72 item no 50 : supply and fixing led street light fitting 70 watt 230 v ac outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with ip 65/66 protection complete all as specified and directed. 73 item no 51 : supply and fixing post top lantern led type 40 watt 230 watt volts ac outdoor type with decorative post top for 360 degree indirect light ip 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. 74 item no 52 : supplying, install and erect in true vertical position steel tubular swaged welded pole complete with ms base plate 6 mm thick and of size 300 x 300 mm, final taper, pole cap, bolts, nuts, washers & screws etc pole made out of erw ms tubing conforming to is 2713 part ii type 410 sp 31 (9.0 metres long) including of holes of reqd nos and size for fixing of cross arms, painting with one coat of red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminous paint for portion embedded in concrete, painting with synthetic enamel paint (first grade/quality) black & yellow colour at lower portion of exposed pole starting from plinth block band of 1200 mm height (4 nos each strip of 150 mm width) complete all as specified and directed. note: earthwork, cement concrete, cross arms etc. will be measured and paid under approprite items. 75 item no 53 : m & l for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to gi earth strip 32x6mm by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, pcc chamber, ci frame and cover, ms funnel with wire mesh all as shown in electrical plate no 3 of ssr part i including excavation and earthwork in any type of soil/strata and testing on completion. note: gi earth strip 32x6 mm and 40 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted. 76 item no 54 : m & l for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to gi wire 4mm by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, pcc chamber, ci frame and cover, ms funnel with wire mesh all as shown in electrical plate no 3 of ssr part i including excavation and earthwork in any type of soil/strata and testing on completion. note: gi iron strip 4 mm and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted. 77 furniture 78 item no 35 : chair easy fd 229 79 item no 36 : chair tublar steel with armsfd 75(m) 80 item no 37 : chair tublar steel without armsfd 75(m) 81 item no 38 : chair verandahfd/map/ ii/06 82 item no 39 : durrie 18x15tp 83 item no 40 : form with back steel fd 78(m) 84 item no 41 : ladder aluminiumfd 1025 85 item no 42 : receptacle pvcfd/e6/map/13 86 item no 43 : stool steel fd 81(m) 87 item no 44 : table 90x60 cm with drawer fd 283 88 item no 45 : table 90x60 cm without drawer fd 284 89 item no 46 : table 90x90 cm marble top fd 300 90 item no 47 : table office clerk steel fd 1004 91 item no 48 : table 90x90 cm steel fd 1009 92 item no 49 : table steel for serving fd 1011 93 item no 50 : teapoy fd 278 94 item no 51 : teapoy verandahfd/e6/map/17 ...

Department Of Pharmaceuticals - Bihar

43710099 bids are invited for augmentation of the electrical installation 415volts mccb 16 ka , 40amp to 63amp 4pole mcb 10ka c curve miniature circuit breaker , supplying and fixing 5 a to 32 a rating for double pole , supplying and fixing 5 a to 32 a rating for single pole , industrial socket , supplying and fixing suitable size gi box with modular plate and cover including providing and fixing 3 pin , supplying and fixing suitable size gi box with modular plate and cover including providing and fixing 6 pin , wiring for light point fan point exhaust fan point call bell , wiring for circuit submain wiring alongwith earth wire , supplying and fixing following size ms conduit along with accessories , supplying and fixing following size medium class pvc conduit along with accessories , earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories , earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories , supplying and laying 25 mm x 5 mm copper strip , supplying and laying 25 mm x 5 mm g.i strip , supply fixing testing and commissioning , supply fixing testing and commissioning of ceiling fan 1200 mm , fencing for transformer , dismantling of existing panel total quantity : 2358...

Dedicated Freight Corridor Corporation Of India Limited - Bihar

43274897 bids are invited for rdso core approved electrical items for trd guy rod 9.3m , anchor loop , guy rod 9.7m , anchor v bolt , bfb steady arm swivel , bfb steady arm hook , register arm eye piece , tubular stay adjuster , tubular stay adjuster large , splice for 125 sq.mm catenary , catenary wire ending clamp , suspention clamp , contact wire dropper clip , contact wire swivel clip and swivel clip , catenary dropper clip , parallel clamp jumper , compensating plate , dropper clip 25mm dia , dropper clip 49mm dia , dropper clip 34mm dia , eqalizing plate , splice , 25mm drop bracket part , large register arm hook , tubular stay sleeve forged , double eye distance rod , guy rod double strap , single clevis , raised register arm adjuster , tube cap 40 mm , tube cap 25 mm , suspention clamp , 25 mm steady arm clamp assembly , p.g clamp , guy rod stirrup , large catenary suspention bracket , double suspention clamp , standard antiwind clamp , earth wire , feeder wire , pg clamp 50 sq.mm jumper 93.3 sq.mm anti creep wire bimettalic sleeve , flat armour tape , large span wire ending clamp 130 , armour tape ferrule , adjuster eye and clevis type , adjuster double clevis type total quantity : 12883...

Northeast Frontier Railway - Bihar

43218867 supply of come along clamps for earth wire ( 19 / 2.5 mm ) galvanized steel with load test certificate from govt. approved lab, similar to design as per drg no. re / 33 / p / 560. ( make im, sste or similar ) . [ warranty period: 30 months after the date of delivery ] , automatic come along clamp 3.5t capacity, suitable for 6mm to 22mm wire ropes / earth wire. ba re copper cable, trolley wire etc., self gripping type made of forged alloy steel parts, as per the specification atta ched make hi tool, japan or similar. [ warranty period: 30 months after the date of delivery ] , come along clamps for aluminium spider conductor ( 20 sq mm ) as per drg. no.re / 33 / p / 550 ( m ake: im, sste or similar ) [ warranty period: 30 months after the date of delivery ] => limited...

Northeast Frontier Railway - Bihar

43182085 supply of come along clamps for earth wire ( 19 / 2.5 mm ) galvanized steel with load test certificate from govt. approved lab, similar to design as per drg no. re / 33 / p / 560. ( make im , sste or similar ) .come along clamps for earth wire ( 19 / 2.5 mm ) galvanized steel with load test certificate from govt. approved lab, similar to design as per drg no. re / 33 / p / 560. ( make im , sste or similar ) ., come along clamps for earth wire ( 19 / 2.5 mm ) galvanized steel with load test certificate from govt. approved lab, similar to design as per drg no. re / 33 / p / 560. ( make im , sste or similar ) . [ warranty period: 30 months after the date of delivery ] => limited...

Bihar Industrial Area Development Authority - Bihar

42999173 request for proposal ( rfp ) for selection of firm / agency / supplier for supply, installation, testing and commissioning of different machines including civil, electrical and other fixtures for setting up food testing lab in upendra maharathi shilp anusandhan sansthan, patna, bihar. list of proposed equipment – chemical 1 highly sensitive triple quadrupole lcms / ms system 2 gas chromatographs with ecd, fid, fpd detector, with headspace and auto sampler ( auto sampler to be provided ) with 5 years consumable and warranty extended upto 5 years 3 gc ms ms with ecd, fid, fpd detector, with headspace and auto sampler ( auto sampler to be provided ) with 5 years consumable and warranty extended upto 5 years 4 icpms accessories and microwave digestion system 5 double beam atomic absorption spectrophotometer 6 high performance liquid chromatography ( gradient ) with uv and fld detector, auto sampler & essential columns with accessories with 5 years consumable and warranty extended upto 5 years 7 uv vis spectrophotometer 8 centrifuge with 5 years consumable and warranty extended upto 5 years 9 ultra low temperature 80 ult freezer 10 ph meter with 5 years consumable and warranty extended upto 5 years 11 elisa reader, filter based plate reader with 5 years consumable and warranty extended upto 5 years 12 heating mantles with 5 years consumable and warranty extended upto 5 years 13 laboratory precision oven uniform temperature 300 o c with 5 years consumable and warranty extended upto 5 years 14 cyclotec lab grinding millwith 5 years consumable and warranty extended upto 5 years 15 magnetic stirrer with 5 years consumable and warranty extended upto 5 years 16 magnetic stirrer with hotplate with 5 years consumable and warranty extended upto 5 years 17 block digestor for eight samples with 5 years consumable and warranty extended upto 5 years 18 moisture analyzer with 5 years consumable and warranty extended upto 5 years 19 muffle furnace 930 degree c with 5 years consumable and warranty extended upto 5 years 20 rectangular hot plate with 5 years consumable and warranty extended upto 5 years 21 refrigerated microcentrifuge with 5 years consumable and warranty extended upto 5 years 22 refrigerators, 2 to 8degreec, capacity 1000l with smart view with 5 years consumable and warranty extended upto 5 years 23 refrigerated incubator orbital shaker ( stackable ) with 5 years consumable and warranty extended upto 5 years 24 soxhlet extraction unit with 5 years consumable and warranty extended upto 5 years 25 nitrogen concentrator ( turbo vap. concentrator ) with 5 years consumable and warranty extended upto 5 years 26 solid phase extraction manifold with 5 years consumable and warranty extended upto 5 years 27 vaccum fitration apparatus along with vaccum pump with 5 years consumable and warranty extended upto 5 years 28 multi tube vortex with mixing, heating, and cooling functions with 5 years consumable and warranty extended upto 5 years 29 analytical weight box, e2 with 5 years consumable and warranty extended upto 5 years 30 analytical weight box, e2, with 5 years consumable and warranty extended upto 5 years 31 analytical balance, 220g x 0.1mg with internal calibration with 5 years consumable and warranty extended upto 5 years 32 microbalance, 5.2g x 0.001mg with internal calibration and static eliminator with 5 years consumable and warranty extended upto 5 years 33 precision balance, 6200g x 0.1 with external calibration with 5 years consumable and warranty extended upto 5 years 34 micro pipette, 30 300 μl, eppendorf with 5 years consumable and warranty extended upto 5 years 35 micropipette, 1 to 10 ml, eppendorf with 5 years consumable and warranty extended upto 5 years 36 micro pipette, 2 to 20 μl, eppendorf with 5 years consumable and warranty extended upto 5 years 37 micro pipette, 10 to 100 μl, eppendorf with 5 years consumable and warranty extended upto 5 years 38 micro pipette, 20 to 200 μl, eppendorf with 5 years consumable and warranty extended upto 5 years 39 micro pipette, 100 to 1000 μl, eppendorf with 5 years consumable and warranty extended upto 5 years 40 rotary vacuum evaporator along with heating bath, diaphragm pump, interface and recirculating chiller rotary evaporator and heating bath with 5 years consumable and warranty extended upto 5 years 41 digital stop watch list of proposed equipment – biological 1 real time pcr system with 5 years consumable and warranty extended upto 5 years 2 b.o.d cooling incubators with 5 years consumable and warranty extended upto 5 years 3 vertical laboratory autoclave ( radial locking ) with 5 years consumable and warranty extended upto 5 years 4 laboratory precision oven uniform temperature 300 o c with 5 years consumable and warranty extended upto 5 years 5 horizontal laminar air flow with 5 years consumable and warranty extended upto 5 years 6 digital top pan balance ( 20 gm 800 gm ) , with 5 years consumable and warranty extended up to 5 years 7 analytical balance ( 0.01mg 20 gm ) , with 5 years consumable and warranty extended upto 5 years 8 stability chamber with 5 years consumable and warranty extended upto 5 years 9 biosafety cabinet type ii b, with 5 years consumable and warranty extended upto 5 years 10 deep freezer 20°c, with 5 years consumable and warranty extended upto 5 years olsc 119 12 11 stomacher, with 5 years consumable and warranty extended upto 5 years 12 homogenizer / lab stirrer, with 5 years consumable and warranty extended upto 5 years outer & inner ss 13 ph meter, with 5 years consumable and warranty extended upto 5 years 14 lab grinding mill ( homogenizer ) with 5 years consumable and warranty extended upto 5 years olsc ls 01 15 vortex mixer, with 5 years consumable and warranty extended upto 5 years 16 refrigerated microcentrifuge with 5 years consumable and warranty extended upto 5 years 17 non refrigerated microcentrifuge with 5 years consumable and warranty extended upto 5 years 18 gel documentation system with printer, with 5 years consumable and warranty extended upto 5 years 19 biosafety cabinet type ii b, with 5 years consumable and warranty extended upto 5 years 20 sonicator, with 5 years consumable and warranty extended upto 5 years 21 binocular microscope / 3d microscope, with 5 years consumable and warranty extended upto 5 years 22 uv cabinet, with 5 years consumable and warranty extended upto 5 years 23 serological water bath, with 5 years consumable and warranty extended upto 5 years 24 electronic colony counter with 5 years consumable and warranty extended upto 5 years proposed cost for furniture and fixture for setting up of testing lab, dept. of industries 1 wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed pvc conduit, with modular type switch, modular plate, suitable size g.i. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc.as required group c 2 wiring for light / power plug with 2x4 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit along with 1 no 4 sq.mm. fr pvc insulated copper conductor single core cable for loop earthing as required. 3 wiring for circuit / submain wiring along with earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface / recessed pvc conduit as required. 2x2.5 sq.mm +1x2.5 sq.mm 2 x 6 sq.mm + 1 x 6 sq.mm. earth wire 2 x 10 sq.mm. + 1 x 10 sq.mm. earth wire 4 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire 4 x 6 sq. mm + 1 x 6 sq. mm earth wire 4 x 10 sq. mm + 1 x 10 sq. mm earth wire 4 x 16 sq. mm + 1 x 16 sq. mm earth wire 4 supplying and fixing pvc / g.i box of 200mm x 250mm x 60mm deep on surface or in recess with suitable size of phenolic laminated sheet cover in fornt including painting etc as required ( adopter box above each d.b ) . 5 supplying and fixing suitable gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pinm 5 / 6 and 15 / 16 amps modular socket outlet and 15 / 16 amps modular switch, connection, painting etc. as required. ( for power plug ) 6 supplying and fixing suitable size g.i box with modular plate and cover in front on surface in recess including providing and fixing 3 pin, 5 / 6 amps modular socket outlet and 5 / 6 amps modular type switch, connection, painting etc., as required. ( for light plugs to be used in non residential buildings ) 7 supply & fixing 8 way double door sp & n, sheet steel, mcb distribution board, 240 volts, on surface / in recess, complete with tinned copper busbar, neutral link, earth bar, din bar, detachable gland plate, interconnections, phosphatised and powder painted including earthing etc.as required ( but without mcb / rccb / isolator ) lighting db ( a ) 40 amps double pole mcb isolator : 1 no. ( b ) outgoing 6 / 32 amps sp mcb ( b series ) :6 nos. 8 supply & fixing 4 way ( 4+12 ) double door tp & n, sheet steel, mcb distribution board, 415 volts, on surface / in recess, complete with tinned copper busbar, neutral link, earth bar, din bar, detachable gland plate, interconnections, phosphatised and powder painted including earthing etc.as required ( but without mcb / rccb / isolator ) power db ( a ) 63 amps double pole mcb isolator : 1 no. 9 ( b ) outgoing 16 / 32 amps sp mcb ( c series ) : 12 nos. s / f following modular type switch / socket on the existing modular plate and switch box including connection but excluding modular plate etc as required. 10 tv antenna socket outlet 11 s / f electronics musical call bell suitable for d.c / a.c. single phase 230 copmplete as required. 12 supplying and fixing batten / angle holder incluiding connection etc as required. 13 supplying and fixing 2 pin, 5 amp, celling rose on the existing junction box / pvc box incluiding connection etc as required. 14 s / f modular blanking plate on the existing modular plate and switch box excluding modular plate as required. 15 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface / recessed steel / pvc conduit as required. electrical fixture fitting 16 supply and installation of 300 mm 230volt ac exhaust fan in the existing opening including making good the damage connection testing commissioning etc as required. 17 supply & installation 400 mm dia 230 volt ac wall / cabin fan including fixing the bracket making connection testing commissioning etc as required. 18 supply and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver directly on false ceiling including connection with 1.5 sq mm fr insulated copper conductor cable and earthing the body etc as required 19 supplying and fixing indoor recess mounting 36 watt led flat panel luminaire suitable for armstrong / grid ceiling and complete with electronic driver etc. directly on false ceiling including connection with 1.5 sqmm fr pvc insulated copper conductor cable and earthing the body etc as required. 20 supplying and fixing of following types lamp in the existing electrical fitting / fixtures etc. as required. 10 / 12 watt led lamp 21 supplying and fixing 90 watt led type street light with die cast aluminium housing for ingress protection of ip65 and complete with all accessories etc, on pole / building including connection with fr pvc insulated copper conductor cable and earthing the body etc. as required. 22 supplying and fixing following sizes of pvc conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. section 4: fire extinguishers p / f with brackets wall mounted fire extinguishers as per details below: 23 abc power type ( stored pressure ) fire extinuisher 4 kg .capacity , isimark ( is: 15683 ) squeeze gripe valve, operating temperature ( +5 deg. to ( +55 ) deg.for class 3a type of fire with abc powder , complete in all respect. 24 co2 type fire extinguisher 4.5kg capacity isi mark ( is : 15683 ) squeeze grip value , operating temperature ( 30deg. to 55deg.foe class 13b type of fire fitted with 1mt.hose & pvc hoen, complete in all respect. earthing 25 providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required. 26 providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. 27 providing chemical / mineral maintenance free earthing system comprising of copper coated earth electrode 3 metre length and 17.2 mm outer dia along with 25 kg earth conductivity enhancing back fill mineral compound for earth electrode to fill up the excavated earth and earth inspection pit etc. as required. 28 providing and fixing copper tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( for horizontal run ) 29 providing and fixing copper tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( for vertical run ) air condition 30 2 ton inverter cassette ac 5 star inverter ( make: mitsubisi / daikin / toshiba / o general ) noise level indoor ( low / mid2 / mid1 / high ) in db ( a ) not below 45 / 49 / 51.outdoor in not below 54 db ( a ) 31 1.5 ton 5 star inverter split ac ( make: mitsubisi / daikin / toshiba / o general ) noise level indoor ( low / mid2 / mid1 / high ) in db ( a ) not below 45 / 49 / 51.outdoor in not below 54 db ( a ) stablizer ( voltage range: ( 90v to 230 v ) extra copper pipe & electrical wires pvc pipe for drain water fire fighting 32 supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices ( including detectors ) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics / lcd display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory ( eprom ) , power supply unit ( 230± 5% v, 50 hz ) , 48 hrs back up with 24 volt sealed maintenance free batteries with automatic charger. the panel shall have facility to connect printer to printout log and facility to have seamless integration with analog / digital voice evacuation system ( which is part of the schedule of work under sh: pa system ) and shall be complete with all accessories. the panel shall be compatible for ibms system with open protocol bacnet / modbus over ip complete as per specifications. ( edwards est ) 1 loop panel. 1 kva line interactive ups with 30 min battery back up 33 supplying and fixing intelligent addressable type multicriteria detector with base for use as heat or smoke or combined both with automatic electronic addressing, microprocessor type with builtin integrated short circuit isolator including testing, commissiong etc as reqd. 34 supplying and fixing intelligent addressable type heat detector with base with automatic electronic addressing, microprocessor type with builtin integrated short circuit isolator including testing, commissiong etc as reqd. 35 sypplying and fixing intelligent addressable manual call point having inbuilt short circuit isolator i / c testing and commissiong etc as reqd. 36 addressable sounder with interface module, power supply for sonder and programmable by software having integrated short circuit isolator & having operating temperature 10⁰c to + 55⁰c 37 analogue addressable control module with ip66 casing containing four relay outputs, each containing a potential free dpdt contact with a fail safe and in built short circuit isolator the ambient temperature range shall be 20c to +60c. 37 analogue addressable monitor module with ip66 casing containing four relayinputs, each containing a potential free dpdt contact with a fail safe and in built short circuit isolator the ambient temperature range shall be 20c to +60c. duel led response indicator ( local ) 38 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. ( malhotra / anchor ) 20 mm dia 39 supplying & drawing following sizes of fr pvc insulated copper conductor single core cables in existing surface / recessed pvc conduit etc. as complete as required ( polycab / havels ) 2 x 1.5 sq.mm 40 kanex brand abc type fire extinguisher cap. 6 kg filled with mono ammonium phosphate powder 50% confirms to is 4308, stored pressure type, ugts pressure gauge, gross weight 8.9 kg, empty weight 2.9 kg, can height 530 mm, diameter 150 ± 10mm, discharge time 24 sec, controllable discharge mechanism, jet range 5 meters, average discharge is 90%, applicable on class a, b & c and electrically started fire, fire rating 4a:144b, can construction : deep drawn & co2 mig welded, epdm rubber hose with both end aluminum clamped, internal coating epoxy powder coating, external coating pure polyester powder coating ( uv resistant ) , brass forged valves with safety pin is of ss material, sheet metal thickness : 1.8 mm, isi approved is 15683:2018. 41 kanex brand co2 high pressure portable 4.5 kg fire extinguisher, filled with co2 gas as per is 15222, gross weight 16.4, empty weight 11.9 kg, control discharge mechanism fitted with 1 meter wire braided hose & flat horn with diffuser nozzle for dispersed discharge of co2, discharge time 12 sec, average discharge is 95%, applicable on class b, c and electrically started fire, fire rating 55b, internal coating is not applicable & external coating is of enamel spray painting, powder coated handle, squeeze grip type valve confirm to is 3224 isi marked, co2 cylinder construction: hot spinning by seamless pipes & bearing isi mark, body confirms to is 7285 and peso approved, extinguishers confirmed to is 15683:2018 and isi marked. 42 clean agent 2 kg fire extinguishers filled with hfc based gas electrically nonconductive non corrosive, colorless and non residual gas, applicable classes a, b, c, and electrical fires, ugts pressure gauge, gross weight 3.6 kg, empty weight 1.6 kg, height 380mm, diameter 106 ± 10mm, discharge time 12 sec, controllable discharge mechanism, jet range 3 meters, average discharge is 95%, deep drawn with mig welding technology, epdm rubber hose with special aluminum discharge nozzle, external coating pure polyester powder ( uv resistant ) , internal coating epoxy polyester powder, brass forged valves with safety pin is of ss material, fire rating 1a:21b, confirms to is 15683 & isi marked. 43 supplyy, installation, testing & commissioning of 5 lb capacity novec1230 dlp assembly with automatic valve push in connector for tube 5lb novec 1230 gas mounting bracket end linear adopter and low pressure switch for monitoring system activation. : kanex / fire trace 44 supply, installation, testing and commissioning of linear pneumatic heat detection tube with all necessary fitting and supports. ( rotarex / fire trace ) 45 supply, installation, testing & commissioning of audio visual alarm. : kanex / fire trace 46 automatic type 5 kg fire extinguishers hfc 236fa, applicable fire classes a, b & c, ugts pressure gauge, empty weight 2.64 kg, full weight 7.64 kg, can height 375mm, diameter 230 ± 10mm, sheet metal thickness : 2 mm, body construction deep drawn with mig welding technology, brass forged sprinkler valves with nozzle is specially designed to give more than 99% discharge. together with orifice characteristic to cover adequately fire risks with scattering cone of 40 to 45° angle. external pure polyester ( uv resistant ) and internal epoxy polyester powder coated, heat sensitive glass bulb of 68 °c. area covered will be 2 2.5 m2 and volume of coverage is 7 m3. brand : kanex cctv 47 network switch: 24 x 10 / 100 / 1000base t, poe, fixed, 2 x sfp 100 / 1000 mbps, 52 gbps sitching performance capacity, 39 mbps forwarding performance rate. 525 k byte packet buffer, 8k mac address table. 9k bytejumbo frame, 170 watt poe power. 48 bullet camera : 1 / 3 3 megapixel progressive scan cmos, pixels 2304 ( h ) x 1296 ( v ) , electronic shutter speed automanual, 1 / 3 ( 4 ) 1 / 100000s, min illumination 0.1 lux, f1.4 ( color ) ; 0 lux ( ir leds on ) , ir distance upto 100 ft ( 30 m ) , depending upon scene reflectance.day / night auto ( icr ) / color / bw, backlight compensation blc / hlc / dwdr , white balance auto / manual, gain control auto / manual, noise reduction3d, privacy masking upto 4 areas, lens focal length 2.7 12mm, max, aperture f1.4, focus control auto , horizontal angle of view 86 28 degree, lens type motorized focus / zoom, video compression h 264 ( main / high / baseline profile ) / mjpeg, resolution 3 mp ( 2304 x 1296 ) , 1080p ( 1920x1080 ) , 720p ( 1280x720 ) , d1 ( 704x576 / 704x480 ) , cif ( 352x288 / 352x240 ) , frame rate main stream 3 mp ( 1 20 fps ) , 1080p ( 1 25 / 30 fps ) , frame rate 49 dome camera: image sensor 1 / 3 3 magapixel progressive scan cmos, effective pixels 2304 ( h ) x 1296 ( v ) , electronic shutter speed min. illumination 0.045 lux, f2.1 ( color ) , 0 lux ( ir leds on ) , ir distance upto 100 ft ( 30 m ) , depending on scene reflectance, day / night auto ( icr ) / color / bw, backlight compensation blc / hlc / dwdr, white balance, auto / manual, gain control auto / manual, noise reduction 3d, privacy masking upto 4 areas, focal length 2.8mm, max. aperture f2.1, horizontal angle of view 92degree, lens type fixed, video compression h264 ( main / high / baseline profile ) / mjpeg, resolution 3mp ( 2304x1296 ) , 1080p ( 1920x1080 ) , 720p ( 1280x720 ) , d1 ( 704x576 / 704x480 ) 50 video recorder: simultaneous multi channel live view, real time recording, playback, network operation, remote access, usb backup, user interface support 16 bit true color graphical menu interface and mouse operation.preview screen 1 / 4 / 8 / 16 / 24 windows, ip video input 24 channels, video standard pal ( 625 line, 50t / s ) , ntsc ( 525 line, 60t / s ) , video compression h264 high profile, display moitor d1;vga & hdmi, hd ( support 1920x1080, 1280x720, 1440x900, 1260x1024, 1024x768, 800x600 ) 51 display: screen size 42 inch or above ( lg / sony / samsung / philips ) , panel technology ips, aspect ratio 16:9, native resolution 1920x1080 ( fhd ) , brightness 350nit or higher, contrast ratio 1100:1 or higher, dynamic cr 500, 000:1 or higher, viewing angle ( hxv ) 178x178, orientation portrait & landscape, operation temperature 0 degree c to 40 degree c, safety ul, eul, emc fcc class a, ip video unit 16 channel, 1 ch, rca ( 2.0 vp p, 1kohm ) two way audio input, 100 mbps incoming bandwidth, 80 mbps bandwidth, 128 remote connection, hdmi / vga output : 1 ch, resolution hard disk 4 tb camera installation and connectivity telephone 52 epabx with 50 line extension up to 80 line with 2 slt / 2 console the equipment shall be electronic type. it shall have microprocessor / micro controller based.it shall employ pcm / tdm / ip, 100% non blocking, ip digital switching technology.it shall have distributed processing architecture, slic and smt design.system power supply should be in built and smps type which input which input ranges from 90 – 265 vac, 48 60 hz & it has to be battery charger circuit inbuilt, so that, in case of power failure the psu can automatically switch to battery and vice versa. it should be suitable for dtmf as well as fsk type of telephone instruments.its capacity shall be suitable for maximum 96 numbers of c.o. lines, 120 analog extension lines and 500 ip extensions. 53 supply, installation, testing & commissioning of termination box for 50 pair epabx system complete as required 54 base phone cli ( panasonic / beetal ) landline phone with caller id facility corded phone numerical keypad 35 call logs3 display lines disclaimer, tone / pulse switchable ring led indication flash pause dynamic change over from pulse tone, 1 year manufacturer warranty 55 digital console phone 56 network switch : 24 x 10 / 100 / 1000base t, poe, fixed, 2 x sfp 100 / 1000 mbps, 52 gbps sitching performance capacity, 39 mbps forwarding performance rate, 525 k byte packet buffer, 8k mac address table, 9k byte jumbo frame, 170 watt poe power. 57 smart ups on line, 5.4 kw / 6 kva with 1 hour backup12 v 65 ah smf battery ups toplogy double conversion on line, power rating ( va / watts ) 5400watts / 6000va, form factor rack / tower convertible; output power capacity 5400 watts / 6000 va, max configurable power 5400watts / 6000va, nominal output voltage 230v, output voltage note configurable for 220 : 230 or 240 nominal output voltage, efficiency at full load 94.00%, output voltage distortion less than 3%, output frequency ( sync to mains ) 50 / 60 hz + / 3 hz, crest factor 03:01, waveform type sine wave, output connections ( 1 ) *hard wire 3 wire ( 8 ) * ( h n + g ) iec 320 c13 ( 8 ) , bypass built in bypass, output short circuit protection yes, parallel redundancy ( option ) 1 + 1, nominal input voltage 230v, input power factor>0.98, input frequency 40 70hz, input connections terminal block, protection thermal circuit breaker ( 250vac / 20a ) , input voltage range for main operations full load 160 285v, input voltage range for mains operation half load 160 285v, high voltage withstand capability 420 vac, green mode range 210 250 vac ( 230 v ) , battery type mintenance free sealed lead acid battery with suspended, electrolyte. 12v 65 ah smf battery for 60 min battery back up. 58 supplying and drawing following pair 0.5 sq. mm fr pvc insulated annealed copper conductor, unarmoured telephone cable in the existing surface / recessed pvc conduit as required. 2 pair networking 59 supplying & fixing rj 45 type computer socket suitable for cat 6 on modue gi box along with base and cover plate in surface or in recess including making connection , soldering etc as required. supplying and drawing utp 4 pair cat 6 lan cable patch cord 1 meter patch cord 2 meter 60 24 port gbe smart managed switch with gbe uplink interfaces 24 ports 10 / 100 / 1000mbps+4 sfp;port standards & functions ieee 802.3 10base t ethernet ( twisted pair copper ) , ieee 802.3u 100basetx fast ethernet ( twisted pair copper ) , ieee 802.3ab 1000base t gigabit ethernet ( twisted pair copper ) , ieee 802.3az compliance autonegotiation, ieee 802.3x flow control; full / half duplex full / half duplex for 10 / 100 mbps speeds, full duplex for gigabit speed;media interface exchange auto mdi / mdix adjustment for all twisted pair ports;switching capacity 56 gbps; transmission method store and forward; mac address table 16, 000 entries per device, maximum 64 bytes packet forwarding rate 41.7 mpps, packet buffer memory 1.5 mb, maximum power consumption 22.45 watts, standby power consumption 17.84 w / 240 v, acoustics 0 dba heat dissipation 76.55 btu / hr certifications ce ( lvd ) 61 category 6, utp 24 port patch panel size 482.6mm x 44.2 ( 19’’ x 1u ) , panel material steel fully powder coated, unshielded rj 45, plug insertion cycle 750 times dc resistance 72ω max, voltage rating 72 vdc max, current rating 1.5a max 62 supply fitting fixing rack 19 12u fully powder coated complete etc as required with complete accessories ( 5 amp x 6 socket, wire manager, rack fan ) valrack / netrack make. 63 wireless n access point interface one 10 / 100mbps rj45 port ( auto mdi / mdix ) , button wps button, reset button, external power supply 9vdc / 0.6a, antenna type 5dbi detachable omni directional antenna, frequency 2.4 2.4835ghz, wireless standards ieee 802.11n, ieee 802.11g, ieee 802.11b, wireless security ssid enable / disable mac address filter 64 / 128 / 152 bit wep encryption wpa / wpa2 / wpa psk / wpa2 psk ( aes / tkip ) encryption wireless modes ap mode, multi ssid mode, client mode, repeater mode ( wds / universal ) , bridge mode, tplink / cisco / netgear panel meter board mb 1 incomer 125a, 415v, ics=icu=25ka rupturing capacity, fp, mccb with extended rotary handle 1 no. 1 no. type 1+2 class i+ii lightning surge arrester 3 pole plus neautral. obo make type no. v25 b+c 3npe385 as per item no. 5094478 with mpcb busbar heat shrinked colour coded aluminium bus bars with smc / dmc busbar supports, nuts & bolts with spring washers. a set of tpn 200a al bus bars. current density shall be 1a / sq.mm instrumentation for incoming 1 no. three phase 0 500v digital voltmeter with selector switch 1 no. 0 125a digital ammeter with cts 125 / 5a and selecter witch 1 set of led type phase indicating lamps with hrc fuses meter compartments meter compartments with electonic meters three phase direct type 10 nos. the vendor shall submit details before fabrication outgoings 25 32a fp mcb 12 nos. supply of main l.t. panel fabricated out of 16swg m.s. iron sheets, compartmentalized type, with epoxy powder protective paint having sufficient housing compartpents for mounting of switchgears as per below mentioned specifications, make: kde / scpl / equivalent design, fabrication and supply of suitable electrical grade enclosure, compartmentalized type with epoxy powder protective paint and panel is to be fabricated out of 16swg make: kde / scpl / equivalent supply and installation of 1000 amp of electrolytic aluminium busbar for power load section. supply and installation of proper dmc busbar supporting system suitable for 1000 amp ratings. 250 amp, 35 ka, tpmccb supply of 160amp, 4pole mccb extended rotary handle make: abb / ge / siemens. 25 / 100 amps. 4 pole mccb, 16 ka cable 3.5 core, 300 sq. mm xlpe / pvc insulated sheathed ( heavy duty ) armoured electric cable with aluminium conductor. 3.5 core, 95 sq. mm xlpe / pvc 3.5 core, 150 sq. mm xlpe / pvc 3.5 core, 185 sq. mm xlpe / pvc detailed estimate for the proposed renovation and upgradation work for food test lab at first & 2nd floor, patliputra industrial area, patna. n.s. 1 parking deck flooring with high build, solvent free textured finish epoxy coating with roller applied 5 mm thick epoxy resin based floor coating nitoflor fc150 over epoxy resin screed nitoflor tf 5000 the intended surface shall be prepared by mile scarification to get mechanical key effect to the primer and the concrete surface for ensuring maximum bonding. strong degrease shall be used to remove the oil deposit on the concrete if any. dust and loose particles shall be cleaned using vacuum cleaners . after which nitoprime 25 shall be applied after mixing the base and hardener mechanically using a slow speed heavy duty drilling machine ( 400 to 500 rpm ) fitted with a suitable paddle to achieve homogeneous mix and applied on the prepared surface. after primer nitoflor tf 5000 shall be applied as a base layer after mixing the base hardener and aggregates throughly and poured on the primed surface and spread evenly to maintain the required thickness of 3 mm. the material should be tampered with a wooden float to ensure complete compaction and finally finished to closed even texture using a steel trowel and cured for seven days. as a finishing coat nitoflor fc 150 shall be applied over the screed surface after mixing mechanically the three components using heavy duty slow speed paddle mixer until achieving a homogeneous mix and spread on the prepared area using medium haired rol;ler for a thickness of 400 microns in two coat. 8.2 providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters facias and similar locations of required size of approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement: 4 coarse sand ) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing etc. complete at all levels. 8.2.2 granite of any colour and shade 8.2.2.2 area of slab over 0.50 sqm 8.3 extra for providing edge moulding to 19 mm thick marble stone counters, vanities etc. over item no. 8.2 mm thick marble stone counters, vanities etc. over item no. 8.2 including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer in charge. granite work 8.3.2 granite work 26.27 providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ≥85%, thermal conductivity k=0.057 w / m k, fire performance as per ( bs 476 pt 6 & 7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanised iron section of 0.33mm thick ( galvanized @120gsm ) comprising of main t runners of 15x32mm of length 3000mm, cross t of size15x32mm of length 1200mm and secondary intermediate cross t of size 15x32mm of length600mm to form grid module of size 600x600mm suspended from ceiling using galvanized mild steel item ( galvanised @80gsm ) 50mm long 8mm outer diameter m 6 dash fasteners, 6mm diameter fully threaded hanger rod upto 1000mm length and l shape level adjuster of size 85x25x2mm, spaced at 1200mm centre to centre along main t. the system should rest on periphery walls / partitions with the help of gi perimeter wall angle of size 24x24x3000mm made of 0.40 mm thick sheet, to be fixed to the wall with the help of plastic rawl plug at 450mm centre to centre & 40mm long dry wall s.s. screws. the exposed bottom portion of all t sections used in false ceiling support system shall be prepainted with polyester baked paint, for all heights. the work shall be carried out as per specifications, drawings and as per directions of the engineer in charge. 26.27.2 with 20mm thick beveled tegular mineral fibre false ceiling tile ( nrc0.7 ) . 12.45.3 providing and fixing false ceiling at all height including providing and fixing of frame work made up of special sections power pressed from m.s. sheet and galvanized in accordance with zinc coating of 120 gms / sqm as per is:277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm at 1200 mm centre to centre one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts to the angle hanger of 25x25x5 mm of required length, and other end of angle hanger being fixed with nut and bolts to g.i. channels 45x15x0.9 mm running at the rate of 1200 mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having clips of 10.5 mm centre to centre shall be fixed in a direction perpendicular to g.i. channel with connection clips made out of 2.64 mm dia x 230 mm long g.i. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall / partition with the help of rawl plugs at 450 mm centre to centre with 25 mm long drive all screws @230 mm interval including jointing and fixing to a flush finish of tapered and square edges of the gypsum board with recommended filler, paper tapes, finishers and two coats of primer suitable for gypsum board as per manufacturers specification and also including the coat of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per the drawing and specification and direction of the the engineer in charge but excluding the cost of painting. 12.5 mm thick tapered edge gypsum moisture resistant board 12.62 extra for any sunk or raised moulding in the plaster of paris ( gypsum anhydrous ) ceilng .all complete as per specification and direction of e / i. ns 2 supplying fitting and fixing roman blinds in jacard cloth finish as per company specification and as per approved colour and sample inclusive of all taxes and royalty all complete as per specifications / approval and direction of engineer in charge. n.s. 3 providing & fixing double skin laminated both side wpc partition upto specified height with 1.0 mm lamination of greenply / marino / century mica over 12 mm thick wpc of alstone / greenply / century ( min wt. 550kg / cum ) make fitted and fixed both sides over aluminium frame of 50 x 50mm posts at 60 cm centres and 50x50mm horizontal members at approx 60 cm centers including cost of anchoring the partition to floors, walls and ceiling properly as per drawing including making hidden doors as per drawing all complete as per drawing, specifications and direction of e / i. providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of engineer in charge ( door handle , lock, and stopper etc . n.s 4 supplying fitting and fixing glass door handles, h type ( qbghl 5 ) made up of stainless steel brushed steel finish 300 mm heigh / equivalent make all complete including taxes and royalty as per approval and direction of e / i. n.s 5 supplying fixing and fitting high security corner lock for patch fitting ( qbpl 1 make ) brushed steel finish made of graded aluminium alloy cast housing slim and compact size light in weight all complete as per specification and direction of e / i ns 6 providing and fixing of 1.0mm laminated ( greenlam / century / merino ) panelling upto specified height over 12 mm thick wpc board of alstone / greenply / century make fitted and fixed over aluminium frame of 25 x 25mm posts at 30 cm centres and 25 x 25mm horizontal members at approx 30 cm centers including cost of anchoring the panelling to walls properly including termite treatment as per drawing specification and direction of e / i. 14.1.1 repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground, all complete as per direction of e / i. cement mortar 1:4. 13.74 removing white or colour wash by scraping and sand papering and preparing the surface smooth including necessary repair scratches etc. complete 13.80 a.2 providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 13.92 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade. 13.92.1 two or more coat on new surface. 9.48 providing and fixing m.s grills of required pattern in frames of windows etc. with m.s flats, square or round bars etc. all comlete. 9.48.1 fixed to steel windows by welding. 13.94 painting with sythetic enamel paint of approved brand and manufacture to give an even shade. 13.94.1 two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. 15.23 dismantling tile works in floor and roofs laid in cement mortar including stacking material within 50 metres lead. 15.23.2 for thickness of tiles above 25 mm and upto 40 mm 15.7 demolishing brick work including stacking of serviceable material and disposal of unserviceable materials within 50 metres lead : 15.7.4 in cement mortar disposal of building rubbish / malba / similar unserviceable, dismantled or waste waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by engineer in charge, beyond 50 m initial section 3: electrical work s.h. i : wiring 1.3.3 point wiring in pvc conduit, with modular type switch: wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq mm fr pvc insulated copper conductor single core cable in surface / recessed pvc conduit, with modular switch, modular plate, suitable g.i. box etc. as required. group c 1.4 twin control point wiring in pvc conduit with modular type switch: wiring for twin control light point with 1.5 sq mm fr pvc insulated copper conductor single core cable in surface / recessed pvc conduit, 2 way modular switch, modular plate, suitable g.i. box etc. as required. 1.5 power plug wiring in pvc conduit ( 2x4 sq. mm ) : wiring for light / power plug with 2 x 4 sq. mm fr pvc insulated copper conductor single core cable in surface / recessed pvc conduit alongwith 1 no. 4 sq. mm fr pvc insulated copper conductor singlre core cable for loop earthing as required. ( for 15 amp socket ) 1.7 circuit / sub main wiring in pvc conduit : wiring for circuit / submain wiring alongwith earthwire with the following sizes of pvc insulated copper conductor, singlre core cable in surface / recessed pvc conduit as required. 1.7.1 2 x 1.5 sq.mm. + 1 x 1.5 sq. mm earth wire 1.7.2 2 x 2.5 sq.mm. + 1 x 2.5 sq. mm earth wire 40185 4 x 4 sq.mm. + 1 x 4 sq. mm earth wire 40550 4x 6 sq.mm. + 1 x 6 sq. mm earth wire 1.16 telephone wiring in existing conduit: supplying and drawing following pair, 0.5 sq. mm fr pvc insulated copper conductor, unarmoured telephone cables in existing surface / recessed pvc conduit as required 1.16.2 2 pair 1.21 s / f pvc conduit: supplying and fixing of following sizes of pvc conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recess conduit as required. 1.21.1 20 mm 1.24 s / f modular type switch / socket : supplying and fixing following modular type switch / socket on the existing modular switch / socketon the existing modular plate& switch box including connections but excluding modular plate etc. as required. 1.24.4 3 pin, 5 / 6 amps socket outlet 1.24.5 6 pin, 15 / 16 amps socket outlet 1.24.6 telephone socket outlet 1.24.8 bell push 1.27.1 s / f modular boxes, base & cover plate: supplying and fixing following size / modules, gi box along with modular base & cover plate for modular switches in recess as required. 1 or 2 module ( 75 mm x 75 mm ) 1.31 s / f light plug point modular type accessories: supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5 / 6 amps modular socket outlet and 5 / 6 amps modular switch, connection, painting etc. as required. ( for light plugs to be used in non residential buildings. ) 1.32 s / f power plug point modular type accessories: supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5 / 6 & 15 / 16 amps modular socket outlet and 15 / 16 amps modular switch, connection, painting etc. as required. 5.4 supplying and fixing replaceable compact commercial batten suitable for single tb led tube complete with 20 watt led polycarbonate tb tube with built in driver etc. directly on wall / ceiling including connections with 1.5 sq. mm fr pvc insulated copper conductor etc. as required. 1.37 providing and fixing ding dong call bell suitable for single phase, 230 volts complete as required. 8.15 supply and installation of regular / standard model a.c. ceiling fan of 1200 mm sweep with service value ( cm / mm ) minimum 4.00, air delivery minimum 270 cum / min including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq mm fr pvc insulated copper conductor etc as required. 5.7 supplying and fixing recess mounted following types led downlighter with minimum efficacy 100 lm / w in pressure die cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm frls pvc insulated copper conductor cable etc as required. 5.7.1 5 / 7 watt 5.7.5 18 watt 5.9 supplying and fixing recess mounted 36 watt led flat panel ( 2 x 2 ) with minimum efficacy 100 lm / w which provides soft light and glare free symmetrical illumination suitable for armstrong / grid ceiling and integrated electronic driver etcdirectly on false ceiling including connections with 1.5 sq.mm frls pvc insulated copper conductor cable etc as required. 5.11 supplying and fixing wall mounted light bracket / fixture made with polycarbonate suitable for single 9 / 10 watt led lamp directly on wall including connections etc as required. ( but without lamp ) 6.1.6 supplying and fixing of following types lamp in the existing electrical fitting / fixtures etc. as required. 14 / 15 watt cfl lamp. 2.12 s / f c series, sp mcb: supplying and fixing following rating, 240 / 415 volts, c curve, miniature circuit breaker, suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 2.12.1 6 / 32 amps, single pole 2.12.2 6 / 32 amps, spn 2.12.4 6 / 32 amps, triple pole and neutral 2.12.8 40 amps, triple pole and neutral 2.19 supplying and fixing 20amp 240 volts spn mcb industrial type, power socket with 25amp spn mcb and 25 amps top in proper size steel box and plate as required. all complete as per instructions of elec.er. / architect. 8.11 supply and fixing of fabricated electrical control panel of cubical construction, floor / wall mounted type, fabricated out of 16 swg crca sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, bus bar chamber, insulator and complete in all respect etc and panel manufactures must be approved by cpri. ( but without ryb inicator, ammeter, voltmeter, inter connection copper conductor cable / solid copper strip, switchgears etc. ) ...

Military Engineer Services - Bihar

42997759 tender for additional / alternator cum special repairs to md accommodation at mil station gaya; 2 item no 01 : m & l for vitrified ceramic tiles light shed 10 mm thick ( square or rectangular ) polished, area of each tiles not exc 0.36 sqm, in floors etc. set and jointed with cement and pointed in white or coloured cement to match over and incl 15mm thick screed bed or bedding layer with cm 1:4 complete all as specified and as directed. 3 item no 02: m & l for vitrified double charge tiles light shed 10 mm thick ( square or rectangular ) polished, area of each tiles exc 0.36 sqm but not exc 0.42 sqm each in floors etc. set and jointed with cement and pointed in white or coloured cement to match over and incl 15mm thick screed bed or bedding layer with cm 1:4 complete all as specified and as directed. 4 item no 03 : roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc.complete all as specified and as directed. 5 item no 04 : m & l for non skid ceramic coloured tiles 7 to 8 mm thick ( square / rectangular ) area of each tile exc 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and incl 15mm thick screed bed or bedding layer with cm 1:4 complete all as specified and as directed. 6 item no 05 : m & l for glazed ceramic coloured tiles in vertical surfaces 450 x 300 x 7 8 mmset and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick rendering in cement mortar 1:4on fair faces of brick work or concrete surfaces as backing for tiles including taking down old tiles complete all as specified and as directed. 7 item no 06 : dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing ) , removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. 8 item no 07 : m & l for machine cut kota stone slab flooring 20 25mm thick incl 15 mm thick cement screed base in cement mortar 1:4laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete including dismantling of stone slab of any thickness.complete all as specified and as directed. 9 item no 08 : m & l for machine cut kota stone slab 20 25mm thick incl 10 mm thick rendering in cement mortar 1:4laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete asin riser of steps, skirting, dado and pillar laid over cement screed and jointedincluding dismantling of stone slab of any thickness.complete all as specified and as directed. 10 item no 09 : s & f in repair ( 18 / 19 mm thick ) laminated with high glossy finish sunmica 1 mm thick ( colour approved by engr in charge ) all sides excluding hinge side, including 5 mm wooden leaping bead ( at hinge side ) for cupboard, kitchen cabinet shutters etc complete all as specified and directed. 11 item no 10 : s & f stainless steel slip on soft closing concealed hinges for cabinet doors, smooth oprating hinges for full overlay doors and windows complete all as specified and directed. 12 item no 11 : m & l for factory made 35 mm thick flush shutters, solid core construction, with block board core and 5 mm thick plywood face panels on both side, commercial type on both sides covered face veneered decorative type etc.complete all as specified and as directed. 13 item no 12 : m & l for pressed steel door frame size 105 mm x 60 mm made of 1.25 mm thick sheet including necessary fixing lugs, hinges, lock strike plate etc., complete, all as specified. 14 item no 13 : m & l for pressed steel door frame size 125 mm x 60 mm made of 1.25 mm thick sheet including necessary fixing lugs, hinges, lock strike plate etc., complete, all as specified. 15 item no 14 : m&l for providing pcc 1:2:4, type b 0 ( using 12.5 mm graded stone aggregate ) as in filling of pressed steel door frame and holdfasts including necessary formwork etc. 16 item no 15 : s&f in stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.18mm and fixed with beeding / staples directed by engr in charge. 17 item no 16 : s&f 4mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares of any size n. exc 0.50 sqm each complete all as specified and directed by engr in charge. 18 item no 17 : s&f 4mm thickfigured glass pin head type and glazing with oil putty or wooden beads in squares n exc 0.50 sqm each pane complete all as specified and directed. 19 item no 18 : s&f in repair 20 25 mm bore cut to length as required aluminium anodised decorative curtain rails with brackets and decorative finails as selected and directed by engr in charge. 20 item no 19 : s&f in repair 600mmx450mm bevelled edge mirror of selected quality glass, 5 mm thick mounted on pvc sheet with aluminium framingfixed to wooden plugs with chromium plated screws with dome screw caps and cup washers fixed in repairs complete all as specified and as directed. 21 item no 20 : s&f in repair 15 mm dia bore bib taps, cast copper alloy chromium plated fancy type with crutch alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed.complete all as specified and as directed. 22 item no 21 : s&f in repair 15 mm dia stop valves / angle valve, cast copper alloy, fancy type chromium plated with long shank and cup ( concealed type ) screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed. 23 item no 22 : s&f in repair pvc connections 15mm size with ptmt nuts of length 600 mm all as specified and as directed. complete all as specified and as directed. 24 item no 23 : s&f cp health faucet 15 mm with flexible tube of stainless steel provided rubber hose and wall hook etccomplete as in repair all as specified and as directedcomplete all as specified and as directed. 25 item no 24 : s& f pvc ( swr ) nahani ntrap / floor trap 75 mm dia with and including cp grating all as specified and as directed complete all as specified and as directed. 26 item no 25 : s&f in repair 25 mm dia ball valves high pressure of ptmt with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed complete all as specified and as directed. 27 item no 26 : s&f in repair 15 mm dia two way angle valves / bib taps, cast copper alloy, fancy type chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed. 28 item no 27 : supply & fix in repair brass chromium plated mixer for wash hand basin for mixing hot and cold water screwed down for iron pipes suitable for 15mm bore pipe complete all as specified and directed by engr in charge. 29 item no 28 : supply & fix in repair brass chromium plated wall mixer ( 2 / 3 hole ) with provision for connection to shower rose for mixing hot and cold water screwed down for iron pipes suitable for 15mm bore pipe complete all as specified and directed by engr in charge. 30 item no 29 : s &f as in repair chromium plated shower rose 125 mm dia with 300mm cp shower arm fancy type fixed to 15mm bore pipeall as specified and directed by engr in charge. 31 item no 30 : s & fbrass chromium plated tublar towel rail 20 mm dia d type 600mm long between flanges with cp screws etc complete all as spd 32 item no 31 : s & f in repair gun metal gate valves, with iron wheel head, screwed both ends for iron pipe flange ends type fixed of 25mm dia all as spd and directed 33 item no 32 : s&f pvc waste pipe size 32 mm x 800 mm flexible with coupling for urinal / whb / sink etc. complete all as specified and directed. 34 item no. 33 : blank 35 item no 34 : s & f male brass threaded adaptor ( mta / mbta / female brass threaded adaptor ( fta / fbta ) 20 mm dia complete all as specified. 36 item no 35 : s & f supplying and laying of cpvc pipes 20 mm outer dia sdr 11 & plain cpvc sdr 11 fittings on walls / ceiling or laying in floors complete all as specified and directed by engr in charge. 37 item no 36 : s & f supplying and laying of cpvc pipes 25 mm outer dia sdr 11 & plain cpvc sdr 11 fittings on walls / ceiling or laying in floors complete all as specified and directed by engr in charge. 38 item no 36a : s & f supplying and laying of cpvc pipes 32 mm outer dia sdr 11 & plain cpvc sdr 11 fittings on walls / ceiling or laying in floors complete all as specified and directed by engr in charge. 39 item no 36b : cleaning reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, complete all as specified and directed by engr in charge. ( bars above 12 mm diameter ) . 40 item no 36c : providing & applying two coats of anti corrosive protective coating ( cbri / csir technology ) for reinforcement bars by brush. sprinkle dry sand when second coat is tacky so as to get rough surface complete all as specified and directed. 41 item no 36d : providing, mixing and applying sbr polymer ( of approved make ) modified cement mortar in proportion of 1:4 ( 1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used ) as per specifications and directions of engineer in charge.note: the pre measurement of thickness shall be done just after the surface preparation is completed and payment under ths item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated sounding / tapping with a blunt metal instruent and / or the 75 mm size cube crushing strength at the end of 28 days to be not less than 30 n / sqmm2 ) . ( 25 mm average thickness in 2 layers ) . 42 item no 37 : taking up or down steel tubing of 15 mm dia and connections, including cleaning for re fixing or removal to store 43 item no 38 : taking up or down steel tubing of 20mm dia and connections, including cleaning for re fixing or removal to store 44 item no 39 : s & f in repair rotational three layer moulded polyethylene water storage tanks ( cylinderical vertical with closed top ) capacity 1000 ltrhoisted and fixed in position all as specified and directed by engr in charge. 45 item no 40 : demolition of brick work or stone / boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. 46 item no 41 : m&l brick work using old size bricks with fly ash bricks straightor curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and directed. 47 item no 42 :taking down cement plaster any description on brick or stone walls or wall tiles etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. 48 item no 43 :m&l for rendering 10mm thick internal surfaces on fair faces of brick work in cm 1:6 as directed by engr in charge. 49 item no 44 :m&l for rendering 15mm thick external surfaces on brick / concrete in cm 1:4 finished even and fair without using extra cement with wpc 2% by wt of cement.note: wpc measured and paid separatly 50 item no 44a :m&l for rendering 10mm thick in cm 1:3 on fair faces of brick or concrete surface of ceiling finished even and smooth without using extra cement complete all as specified and directed. 51 item no 44b :m&l for two coats of distemper with acrylic distemper in newly plastered ceiling care in two layers and making the surfaces smooth & uniform including removing existing treatment complete all as specified and directed. 52 item no 44c :m&l for two coats of weather proof external acrylic emulsion paint on projected portion to wall over on external surfaces of old plastered / concrete complete all as specified and directed. 53 item no 45 :m & l for preparation of newly plastered surfaces ofwall & concrete and applying 2mm thick wall care putty including preparation complete. 54 item no 46 :m & l for preparation of oldsurfaces ofwall & concrete and applying 2mm thick wall care putty including removal of existing treated surface. complete all as specified and as directed. 55 item no 47 :m&l for applying two coat of acrylic distemper over a coat of primer inclu preparation of newplastered wall surfaes complete all as specified and as directed. 56 item no 48 :m&l for applying two coat of acrylic distempe as in ceiling incl removal of existing treatment of old treated ceiling surfaces complete all as specified and as directed. 57 item no 49 :m&l for 2 coatsweather proof external acrylic emultion paint over a coat of primerincluding preparation of newly plastered complete all as specified and directed 58 item no 50 :demolition of concrete in ground floors and pavings including floor tiles n exc 15 cm thickness ( below or above ground level ) complete all as specified and as directed. 59 item no 51 :m & l for cement concrete type b 0, 1:2:4 ( 12.5 mm graded aggregate ) , 25 mm thick in flooring etc complete all specified and as directed 60 item no 52 :m & l for 75 mm thick cement concrete type c 1, 1:3:6 ( 20mm graded aggregate ) as in sub base complete all as specified and as directed. 61 item no 53 :m&l for granite ( any type ) work ( table rubbed and polished ) 18 to 20 mm thick in working platform and like including cutting for sink etc. in cement mortar ( 1:4 ) including rounding of edges and pointing in white cement ( 1:2 ) using marble dust with admixture of pigment to match.complete all as specified. 62 item no 54 :m & l two coats of synthetic enamel painting on steel surfaces exc 10 cm width or girth over one coat of red oxide primer including preparation of new steel surfaces. 63 item no 55 :m & l two coats of synthetic enamel painting on wooden surfaces exc 10 cm width or girthover one coat of pink primer. 64 item no 56 :m & l for tmt reinforcement bars 8 mm dia & over cut to length, bent to shape required, including crancking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire ( annealed ) not less than 0.9 mm dia or securing with clips complete 65 item no 57 :m&l rcc type b 1, 1:2:4 ( using 20 mm graded stone aggregate ) in slabs, cantilever or supported on walls and small works like cubes etc.complete all as specified and as directed. 66 item no 57 a :demolition of cement concrete ( reinforced ) n ground floor and paving n exc 150 mm thick ( below or above ground level ) complete all as specified and as directed. ( reinforcement cut as required to facilitate demolition ) . 67 item no 58 :m&l for pvc ( swr ) pipessingle socketed, in any length with rubber ring joints, laid in trenches or in floors or walls of 110 mm bore of pipe etc complete all as specified and directed. 68 item no 59 :m&l for pvc ( swr ) pipessingle socketed, in any length with rubber ring joints, laid in trenches or in floors or walls of 75 mm bore of pipe etc complete all as specified and directed 69 item no 60 :demolition and breaking up drain pipes upto 100 mm dia ( salt glazed ware, ac or reinforced concrete ) set in cement mortar complete all as specified and as directed. 70 item no 61 :s&f pvc ( swr ) bends isi marked any radius of 110 mm borewithaccess door complete all as specified and directed. 71 item no 62 :s&f pvc ( swr ) bends isi marked any radius of 75 mm borewithaccess door complete all as specified and directed. 72 item no 63 :s&f pvc ( swr ) junction single, ( single t ) equal or un equal of 110 mm bore of pipe with access door complete all as specified and directed 73 item no 64 :s & f of pvc ( swr ) vent cowl for 110 mm bore pipe complete all as specified and as directed. 74 item no 65 :s&f aluminium handles cast type anodised handles, d shape of size 150mm complete. isi marked 75 item no 66 :s & f as in repairalluminum alloy, anodised, cast type or extruded section, sliding door bolt with hasp & staple ( bolt type ) with fixing clips and bolts and 250 mm long complete all as specified. 76 item no 66 a :s & f as in repairalluminum alloy, anodised, cast type or extruded section, sliding door bolt with hasp & staple ( bolt type ) with fixing clips and bolts and 300 mm long complete all as specified. 77 item no 67 :s & f in repair sinks made of stainless steel 1.00mm thick with waste coupling with all necessary fittings, kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and as directed. 78 item no 68 :s & f in repair vitreous china wash basin oval shape white flat back size 550 x 400mm with waste coupling with all necessary fittings, chain & plug and porcelain stopper but including brackets or fixed to walls with anchor fastnersall as specified and directed by engr in charge. 79 item no 68 a :s & f vitreous china wash basin oval type of size 560 x 400 x 205 mm counter top and supply of waste pipe and cp waste coupling 32 mm dia completeall as specified and directed. 80 item no 69 :s & f of vitreous china wash down water closet pan ( pedestal pattern ) , white including fixing bolts, but excuding flushing cistern and flush pipe complete. complete all as specified and as directed. 81 item no 69 a :s & f of vitreous china wash down water closet of cascade nxt wall hung of size 670x365x770mm ( including cover ) including flushing cistern & seat cover including all required fitting complete all as specified and as directed. 82 item no 70 :s & f as in repair10 litre pvc valveless, syphonic action type, dual type flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete. 83 item no 71 :s & f as in repair soft closing white seat cover forewc incl accessories complete all as spd 84 item no 72 :m & l for repair of sunken slab as under : ( a ) m & l for application of 1:3 cement – sand mortar, mixed with sika latex emulsion ( 300 gram in 1 kg cement ) , as a coving at the corners of floor and the vertical surface in the sunken area and between floor and walls in the remaining area. ( b ) m & l for application of sika top seal 109hi @ 2.20 kg per sqm each coat or as per manufacture instruction– acrylic based, ready to use, cementitious, water proof coating onto the prepared surface in a continuous film on the floor of the sunken area, taking the coating over the vertical surfaces on to the floor and over the coving on to the wall ( before tiling ) to at least 300mm above the final finished floor level. the coating shall also be continued on to the inner surfaces of the pipe penetration holes. two coats shall be applied & fiber glass cloth to be laid in between coats. ( c ) m & l for application of sikagard 694 f ( i ) @ 100 gram per sqm or as per manufacture instruction, a moisture insensitive epoxy putty in a continuous, 10mm thick gasket around the pipes to a width of approximately 15mm. ( d ) m & l for application of protective screed concrete at a desired thickness admixed with sika cim pink @ 100 gram per sqm or as per manufacturer instruction 85 item no 73 :s & f stainless steel but hinges, medium weight cold rolled of size 100 mm . 86 item no 74 :s & f 150 mm long aluminium anodised barrel tower boltof extruded section 87 item no 75 :s & f 200 mm long aluminium anodised barrel tower boltof extruded section 88 item no 76 :taking down chowkhats or frames not exc 1.5 sqm ( without taking shutters from the frame ) . 89 item no 77 :taking down chowkhats for frames exc 1.5 sqm but n exc 4.00 sqm ( without taking shutters from the frame ) . 90 item no 78 :s & f 35 mm thick 2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc ( without sash bars ) edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc fitted to chowkhats for doors etc complete. 91 item no 79 :s & f solid pvc door frame of size 50mm x 47mm made out of 5mm single side prelam pvc sheet & edges will be painted to match with prelam sheet reinforced with m.s. square tube, suppling & fixing in opening as per specification & drawing complete all as specified and as directed. 92 item no 80 :s & f solid pvc factory madedoor shutter of 30mm ( style ) consisting of frame made out of ms tubes for top bottom rails ms frame shall be covered with heat moulded plain coloured pvc c channel having a pvc sheet strip 20mm width stuck inside with solvent cement for stilesa and plain coloured pvc sheets for top rail, lock & bottom rail on either sides & as gap insert for top rail & bottom rail panelling ofplain colour pvc sheet to be fitted in the ms frame welded / sealed to the stiles & rails with suitable pvc sheet beeding and jointed together with solvent cement as pere specification and drawing complete all as specified and as directed. 93 item no 81 :m&l for providing water proofing treatment over cleaned roof surfaces with super thermo app modified water froofing membran comprssing of following for non approachable roof: ( i ) removal of existing roof treatment and cleaning sweeping and washing and down with water to remove all dust etc from plastred roof surfaces / wall and filling of crack with sealing compound etc. ( ii ) bitumen based primer conforming to is 3384 1965 at 0.30 kg per sqm. ( iii ) one layer of super thermo app modified water proofing membran with non polyster reinforcement of make ( m / s stp texsa ltd / hyperplus membrane of m / s iwl india ltd. m / s stp and tikki tar ltd ) 3mm thick and minimum weight @ 3.50 kg / sqm laid with gas torch and fasted on roof surfaces with roller. the over laps shall be sealed by flame including vertical surfaces after cutting necessary grooving and making good with pcc gola 1:2:4 type b1 etc adhere to bitumen all as per manufacturer instructions. ( iv ) applying two coat of aluminium paint @ 0.20 kg / sqm per coat over bitumen layers as per manufacturer instruction ( application including side lap overlaps shall be provided not less than 10cm and jointed sealed with torch as per manufacturer instruction specification. 94 item no 81 a :m & l for machine cut and polished cement concrete tile factory made with grey cement without pigment of size 250 mm x 250 mm x 22 / 20 mm thick laid in neat cement slurry over and including 20 mm thick screed bed in cm 1:4 mixed chemical compound as per manufacturer instructions and tile properly laid with 3 mm wide joint filled with chemical like tile grout as per manufacturer instructions complete all as specified and directed. 95 item no 82 :supply only liquid water proofing compound isi marked. 96 item no 83 :m & l for machine pressed precast conctete interlocking paver block any shape and size confirming to is 15658 2006 of 60 mm thickness m 35 grade with grey cement and no pigment complete all as specified and directed. 97 item no 84 :sand filling under floors for cushioning ofincluding watering and consolidation 98 item no 85 :s&f mild steel framed works such as grills, gratings, etc, with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work for portions framed and hung as gates, including pintle hinges, stops, hand made sliding bolts, etc conforming to fe 290 gde e 165. 99 item no 86 :m & l for providing, cement concrete type b1, 1:2:4 ( using 20 mm graded stone aggregate ) in cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary form work all as specified and as directed 100 item no 87 :m & l formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick for rough finished flat surfaces ( horizontal or sloping ) all as specified and as directed 101 item no 88 : s & f of supply and fixing factory made upvc white colour three track three panels sliding window with fly proof s.s wire mesh ( two nos. glazed & one no. wire mesh panels ) upto 1.50m height made of ( big series ) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. ( area of window above 1.75 sqm ) comprising of upvc multi chambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length ( shape & sizeaccording to upvc profile ) , appropriate dimension of upvc extruded glazing beads and upvc extruded interlocks, epdm gasket, wool pile, zinc alloy ( white powder coated ) touch locks with hook, zinc alloy body with single nylon rollers ( weight bearing capacity to be 40 kg ) , g.i fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed by engineer in charge. ( glass or wiremesh shall be paid separately ) note: for upvc frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 102 item no 89 : supply and fixing factory made upvc white colour fixed glazed window / ventilator made of ( small series ) frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension ( area upto 0.75 sqm. ) comprising of upvc multi chambered frame and mullion ( where ever required ) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length ( shape & size according to upvc profile ) , upvc extruded glazing beads of appropriate dimension, epdm gasket, g.i. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. profile of frame shall be mitred cut and fusion welded at all corners, mullion ( if required ) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of engineer in charge. ( glass shall be paid separately ) . note: for upvc frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.complete all as specified and as directed. 103 item no 90 : s & f powder coated aluminium frame / shutters for windows, ventilators sliding / openable etc icluding joining cleat for fixing, locking arrangement, rubber beading, screws, etc complete all as specified. note : ( i ) glazing and wire mesh shall be measured and paid separetely only as the labour element included in the relavent item. ( ii ) item shall be paid as per weight of aluminium section ( iii ) the rate quoted shall be inclusive of the cost of neoprene beading, glazing pin, screws and powder coated fittings such as locking arraangement etc as required, which shall not be measured for arriving the weight ( iv ) the rate shall also be inclusive of complete packing with silicon gel around contacting surfaces of aluminium work, and including matching the existing. note: aluminium windowchowkhat and shutters are to be made as per td / issued by hq chief engineer jabalpur zone. 104 item no 91 : dismantling wrought iron or mild steel work of any description such as mild steel window / ventilator complete all as specified and as directed. 105 item no. 92 : taking down copper / aluminium point wiring ( light, fan, bell, socket or power ) complete includingfittings etc. romoving meterials to store for keeping i safe custody or for taking credit ( credit a for above items should be made as per condition seperately ) and making good distrubed surfaces of walls, floors etc complete all as specified and directed at site by engineer in charge. 106 item no. 93 : taking down old / unserviceable distribution board by disconnection of electric connection carefully spn dbs / tpn dbs / main switch including old unserviceable mccbs / mcbs, isolators, etc and making good to disturbed surface complete all as specified and directed by engineer in charge. 107 item no. 94 : taking down carefully copper / aluminium sub main wiring of any size from surface / concealed / existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed. 108 item no. 95 : taking down existing geyser of any capacity after disconnecting all necessary electrical and water supply connections and deposit to mes store yard of age e / m no ii complete all as specified and directed. 109 item no. 96 : taking down ceiling fan / exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan blsdes and deposit to mes store yard of age e / m complete all as specified and directed. 110 item no. 97 : taking down existing single phase electric energy meter of any capacity after disconnecting all necessary electrical connections and deposit to mes store yard of age e / m complete all as specified and directed. 111 item no. 98 : m&l for point wiring with 1.5 sq mm single core pvc insulated unsheathed frlsh cable multi stranded copper conductor cable in and including concealed rigid non metallic pvc conduit heavy duty grade of size 20 / 25mm isi marked inclusive of tees, bend, elbows etc upto and including sunk in anodized pressed steel box for housing switch socket etc with white laminated 3 mm thick hylam sheet cover isi marked of suitable size complete including pvc insulated multi stranded copper conductor 1.5 sq mm frlsh cable as earth wire to common earth dolly for connection to ceiling rose to earth terminal including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed by engineer in charge: 112 ( a ) one light point controlled by one, one way switch 5 amps 113 ( b ) one fan point / exhaust fan point controlled by one, one way switch 5 amps and regulator 114 ( c ) one light point controlled by one, two 2 way switches 5 amps 115 ( d ) one 3 pin 5 amps switch socket outlet point controlled by one switch on the same board. 116 ( e ) one 3 pin 5 amps switch socket outlet point controlled by one switch on the independent board 117 ( f ) one bell point controlled by one, bell switch 5 amps 118 item no. 99 : all as per item no 98 here in before but with 2.50 sq mm single core copper of multistranded frlsh pvc insulated un sheathed 1100 volts grade for 5 / 15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor frlsh pvc wire as earth continuity conductor along with wiring and connecting to the common earth dolly. 119 item no. 100 : m&l for point wiring using approved colour coding as per is, with multistranded copper conductor1.5 sqmm ( nominal area ) , two single core pvc insulated and unsheathed frlsh cable 1100 volts grade isi 694 marked drawn through in and including heavy duty pvc concealed conduit of white / ivory colour including all accessories after chasing in wall / ceiling etc, heavy duty isi marked, with gi sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable size for modular switches, including pvc insulated multistranded copper conductor 1.5 sqmm ( nominal area ) single core frlsh cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for following: 120 ( a ) one light point controlled by one, one way switch 5 amps 121 ( b ) one fan point / exhaust fan point controlled by one, one way switch 5 amps and regulator 122 ( c ) one light point controlled by one, two way switches 5 amps 123 ( d ) one 3 point 5 amps switch socket outlet point controlled by one switch on the same board. 124 ( e ) one 3 pin 5 amps switch socket outlet point controlled by one switch on the independent board 125 ( f ) one bell point controlled by one, bell switch 5 amps 126 item no. 101 : description all as per item no 100 here in before but using 2.50 sq mm single core copper conductor cable of multistranded frlsh pvc insulated un sheathed 1100 volts grade for 5 / 15 amps switch socket combination point including necessary running of 2.5 sq mm copper conductor frlsh pvc wire as earth continuity conductor along with wiring and connecting to the common earth dolly. 127 item no. 102 : description all as per item no 100 here in before but using 4.0 sq mm single core copper conductor frls cable of multistranded pvc insulated un sheathed 1100 volts grade for 5 / 15 amps switch socket cobmination point including necessary running of 4.0 sq mm copper conductor frls cable as earth continuity conductor along with wiring and connecting to the common earth dolly. ( for ac ) 128 item no. 103 : s&f switch piano flush type single pole, 5 amp, 230 volts complete all as specified and directed. 129 item no. 104 : s&f switch piano flush type single pole, 15 amp, 230 volts complete all as specified and directed. 130 item no. 105 : s&f switch piano flush type 2 way switch 5 amp, 230 volts complete all as specified and directed. 131 item no. 106 : s&f switch bell push piano type 5 amp, 230 volts complete all as specified and directed. 132 item no. 107 : s&f socket outlet 2 in 1, 5pin, 5amp, 230 volts complete all as specified and directed. 133 item no. 108 : s&f socket outlet 2 in 1, 5pin, 5 / 15amp, 230 volts complete all as specified and directed. 134 item no. 109 : supply and fixing ceiling rose surface bakelite 3 terminals, isi marked for batten fitting complete all as specified. 135 item no. 110 : s&f stepped type electronic fan regulator flush type complete all as specified and directed by engineer in charge. 136 item no. 111 : s&f for moduler switch piano flush type single pole, one way and 5 / 6 amp single module complete all as specified and directed. 137 item no. 112 : s&f for moduler switch piano flush type single pole, one way and 15 / 16 amp single module complete all as specified and directed. 138 item no. 113 : s&f for moduler switch piano flush type single pole, two way and 5 / 6 amp single module complete all as specified and directed. 139 item no. 114 : s&f for moduler socket outlet multipurpose having provision for 3 pin, 5 / 6 amp and 2 pin, 5 / 6 amp, 2 module piano flush type complete all as specified and directed. 140 item no. 115 : s&f for moduler socket outlet multipurpose having provision for 3 pin, 15 / 16 amp and 3 pin, 5 / 6 amp, 2 module piano flush type complete all as specified and directed. 141 item no. 116 : s&f for module step type fan regulator 120 watt 2 module suitable for 230 volt 50 hz ac supply complete all as specified and directed. 142 item no. 117 : s&f for bell push modular 6 amps single module complete all as specified. 143 item no. 118 : supply and fixing lamp holder pcv / polycarbonate type with back plate suitable for batten / slating fitting complete all as specified and directed by engineer in charge. 144 item no. 119 : s&f for bell electric ding dong type suitable for operation on 230 volt 50 hz ac supply complete all as specified and directed by engineer in charge. 145 item no. 120 : s&f for modular type tv socket out letcomplete all as specified and directed. 146 item no. 121 : m&l for sub main wiring with approved colour coding as per is with four single core pvc insulated frlsh cable with stranded copper conductor of 6 sq mm nominal area and drawing into suitable size of pvc non metallic rigid heavy duty pvc conduit of white / ivory colour and its accessaries isi marked heavy duty of suitable size including concealed in wall etc one run of conductor frlsh cable with 6.0 sqmm ( nominal area ) stranded copper conductor frlsh cable as earth wire complete all as specified and as directed. note: four runs of 6 sqmm cable for phase and neutral and one run of 6 sqmm cable for earthing and one run of pvc conduit will be measured as one unit. 147 item no. 122 : m&l for sub main wiring with approved colour coding as per is with two single core pvc insulated frlsh cable with stranded copper conductor of 6 sqmm nominal area and drawing into suitable size of pvc non metallic rigid heavy duty pvc conduit of white / ivory colour and its accessaries isi marked heavy duty of suitable size including concealed in wall etc one run of pvc insulated with 6.0 sqmm ( nominal area ) stranded copper conductor frlsh cable as earth wire complete all as specified and as directed. note: two runs of 6 sqmm cable for phase and neutral and one run of 6 sqmm cable for earthing and one run of pvc conduit will be measured as one unit. 148 item no. 123 : supply and fixing for sheet metal enclosure mcbdb tpn 4 way vertical type with 200amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the dbs in wall by cutting the brick / stone masonary etc and making good of distributed surface to match with existing colour of wall complete all as specified and as direced. 149 item no. 124 : supply and fixing for sheet metal enclosure mcbdb spn 8 way with 200 amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the dbs in wall by cutting the brick / stone masonary etc and making good of distributed surface to match with existing colour of wall complete all as specified and as direced. 150 item no. 125 : supply and fixing for mcb tripple pole and neutral rated capacity 63 amps 415 volts breaking capacity 10 ka, c curve complete all as specified and as direced. 151 item no. 126 : supply and fixing for mcb tripple pole and neutral rated capacity 32 amps 240 volts breaking capacity 10 ka, c curve complete all as specified and as direced. 152 item no. 127 : supply and fixing for mcb single pole rated capacity 5 to 32 amps 240 volts breaking capacity 10 ka, c curve complete all as specified and as direced. 153 item no. 128 : supply and fixing for metal clad box suitable for 230 volts 50 hz ac supply three pin with mcb sp 20 / 32 ampsremoval of old unserviceable one complete all as specified and as direced. 154 item no. 129 : s&f for water heater storage type ( geyser ) vertical / horizental type as per site requirement with inner container of capacity 25 ltrs, electrically operated, ac 230 volts, bee 5 star rated with all accesseries such as safety valve, thermostate, nrv, isi marked including 04 nos of hold fashner nuts required suitable size fixed in brick wall, including 02 no steel braided pipe 450 mm length pvc connection pipe hot & cold for officers jcos and or accn complete all as specified and as directed. 155 item no. 130 : s & f ceiling fans complete with blades, down rods, and accessories, 230 v, 1200 mm sweep. min air adelivery 210 cfm with service value 6.0 bee. five star rated with brushless direct current motor ( bldc ) complete all as specified and as directed. 156 item no. 131 : labour only for refixing the ceiling fan / exhaust fan obtained from dismantling with replacement of unsv 3 core pvc insulated pvc sheated 3 core multistranded copper conductor cable of size 23 / 0.193 from ceiling rose to fan terminal including over hauling the fan, painting of ceiling fans complete two coats synthetic enamel paint by spraying including filling cavities with filler after cleaning all dust etc. complete all as specified and as directed. 157 item no. 132 : s & f for highly efficient led bulbs 10 w with luminous efficacy not less than 105 lm / watt, used as a ready replacement for existing old gls / cfl direct fit lamp, in b 22 cap of complete all asspecified and directed. 158 item no. 133 : s&f for decorative wall mounted luminaire made out of polycarbonate with unbreakable globe suitable for led bulb and provision of led bulb 10 w with luminous efficacy not less than 105 lm / watt, complete all as specified and as directed. 159 item no. 134 : s&f for led 10 watts batten luminous efficacy having not less than 120 lm / watt aluminium extruded with decorative end caps complete all as specified and as directed. 160 item no. 135 : s & f energy saving new generation 10 watts led, luminous efficacy having not less than 110 lm / watt bulk head fitting ip 65 luminaire with opel diffuser pre wired, with warranty option of 5 years from date of installation and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23 / 0.193 form ceiling rose to fitting including led bulb complete all as specified and directed. 161 item no. 136 : s & f for wall mounted led tube light fitting 20 watts led luminous efficacy having not less than 120 lm / watt batten for surface mounted, anodized extrded aluminium housing, high transmissitivity diffuser, high lumen output box type fitting, 230 volts and intregated electronic driver connector block etc with warranty option of years from date of installation complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23 / 0.193 from ceiling rose to fitting complete all as specified and as directed. 162 item no. 137 : s & f for energy saving new generation environmental friendly long life versatile presure die cast aluminium ip 66 for security light fitting luminaire with high power leds as light source and electronic driver of capacity 25 watts, luminous efficacy having not less than 110 lumen / watt with pre wired and necessary mounting arrangements andprovision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia gi pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by engineer in charge. 163 item no. 138 : s&f for energy effcient exhaust fan of 230 mm sweep made of metal body ventil air ds type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of pvc flexible copper cable of size 23 / 0.0076 two core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for fan base complete all as specified and directed. ( note: cost of suitable opening wall for fixing exhaust fan is deemed to be included in overall rate quoted ) . 164 item no. 139 : s&f for pvc non metallic rigid conduit isi marked heavy duty white / ivory colour and its accessories heavy duty isi marked of size 20 mm dia for lan, telephone and tv connections including cutting chases and making good disturbed surfaces to match with existing finish with plaster complete all as specified and directed. 165 item no. 140 : supply, installation, commissioning and testing indoor type lt wall mounting panel board of minimum size 1.50m ( height ) x 1.20 m ( breath ) x 0.30 m ( depth ) factory made cpri approved panel, weather, dust & vermin proof indoor, double door, front openable, including four comparment for fixing of four nos three phase kwh meter, one no single phase meter and mcb tpn and providing glass view for reading of meter and providing rubber / pvc gasket of suitable size all sides of door, with copper strip / wire busbar of suitable size to mccb input and mccb / mcb output of suitable length for connection of cable from main busbar, made out of 2.00 mm thick mild steel crca sheet with suitable size angle iron supporting frame including applying two coats of powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfaces suitable for 3 phase 4 wire system 415 / 440 volts grade including complete internal wiring with 10 sqmm copper wire and connections of all outgoing / incomming existing cable of any size complete all as specified and directed by engineer in charge. ( for officers g+1 md accn ) incomming ( a ) copper strip busbar of size 30 x 5 mm wrapped with pvc sleeves with maintained the colour code and provision of making holes with copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends = 04 nos 166 ( b ) mccb ip 44 and ip 66 / 67 protection, 4 pole, 415 volts, lcu=25 ka breaking capacity, rating 100 amps, adjustable thermal magnetic release including all fixing accessories with both ends spreader links 01 no ( c ) digital voltmeter of range ( 0 500 ) volts, flush mounting type of size 100mm x 100mm ( 4x4 ) square dial with selector switch 01 no. ( d ) led neon indicator lamp ( ryb ) with holder, 230 / 250 volts, ac 01 set ( set of three ) outgoing ( a ) mcb, tripple pole & neutral, 40 amps, 415 volts, c curve, 10 ka complete all as specified and directed 4 nos ( officers accn ) ( b ) mcb, single pole & neutral, 10 amps, 240 volts, c curve, 10 ka complete all as specified and directed 4 nos ( stair case lighting ) ( c ) fixing only serviceable existing electric meter 01 no ( obtained from demolition / dismantling ) 167 ( d ) supply and fixing of three phase electronic energy meter accuracy class 1.0, 240v, with in home display 10 60a, 3 nos self locking meter seal, lcd display with with optical part, anti temper features, lcd test, serial no. date, rtc, cumulative kwh, last bill kwh, instranteous load, last bill md, instantaneous kw, volts, pf, hz, md, total tamper count, self billing code, battery backup in absence of power for display active energy kwh, including all incoming and out going connections 04 nos 168 item no. 141 : supply, installation, commissioning and testing indoor type lt wall mounting panel board of minimum size 1.20m ( height ) x 1.20 m ( breath ) x 0.30 m ( depth ) factory made cpri approved panel, weather, dust & vermin proof indoor, double door, front openable, including four comparment for fixing of five nos single phase meterand mcb and providing glass view for reading of meter and providing rubber / pvc gasket of suitable size all sides of door, with copper copper busbar wrapped with pvc tape / sleeves with maintained the colour code and copper strip / wire busbar of suitable size to mccb input and mccb / mcb output of suitable length for connection of cable from main busbar, made out of 2.00 mm thick mild steel crca sheet with suitable size angle iron supporting frame including applying two coats of powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfaces suitable for 3 phase 4 wire system 415 / 440 volts grade including complete internal wiring with 1.5 sqmm copper wire and connections of all outgoing / incomming existing cable of any size complete all as specified and directed by engineer in charge. ( for : g+1 jco, or, md accn ) incomming ( a ) copper strip busbar of size 25 x 5 mm wrapped with pvc sleeves with maintained the colour code and provision of making holes with copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends = 04 nos 169 ( b ) mccb ip 44 and ip 66 / 67 protection, 4 pole, 415 volts, lcu=25 ka breaking capacity, rating 63 amps, adjustable thermal magnetic release including all fixing accessories with both ends spreader links 01 no ( c ) digital voltmeter of range ( 0 500 ) volts, flush mounting type of size 100mm x 100mm ( 4x4 ) square dial with selector switch 01 no. ( d ) led neon indicator lamp ( ryb ) with holder, 230 / 250 volts, ac 01 set ( set of three ) outgoing ( a ) mcb, single pole & neutral, 40 amps, 240 volts, c curve, 10 ka complete all as specified and directed 6 nos ( b ) fixing only serviceable existing electric meter 05 no ( obtained from demolition / dismantling ) 170 item no. 142 : taking down existing old extg unserviceable lt under ground / service cable of any description and sizecomplete all as specified and directed. 171 item no. 143 : supply and lay cable xlpe insulated screened pvc bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty ) 1100 volts grade with stranded aluminium conductor of following sizescomplete all as specified and directed 172 ( a ) 3.5 core x 35 sqmm 173 ( b ) 4 core x 16 sqmm 174 item no.144 : excavation in trenches n exc 1.5m wide n exc 1.5m in depth for foundation etc. for laying pipe lines and cablesand getting out as in soft / loose soil complete all as specified and directed. 175 item no. 145 : returning filling in, including spreading, levelling, watering and ramming in layers not exc 25cm in soft / loose soil complete all as specified and directed. 176 item no.146 : removing excavated material to a distance not exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed. 177 item no.147 : supply and laying river bed fine sand in trenches / ducts 8 cm under cable and 15 cm above the cable for cushioning / protection to cable including spreading, levelling and get thick 18 cm after hand punning complete all as specified and directed at site. 178 item no 148 : supply and laying for brick of common burnt clay, sub class b old size laid flat and dry on cables as in cable protection in trenches over cables perpendicular to direction of cales abutting each other complete all as specified and directed. 179 item no. 149 : m&l for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6mm thick buried directly in ground ( earth pit not less than 2.25 m deep below ground level ) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to gi earth wire 4mm dia by means of bolts, nuts, washers of galvanized iron or steel all as shown in electrical plate no 3 and testing on completionincluding adequate charcoal dust comman salt necessary excavation earth work pcc ( 1:3:6 ) type c 1 pit with precast rcc cover slab 40 mm thick in pcc ( 1:2:4 ) type b 1 reinforced with 6 mm dia ms bars @ 100 mm c / c both ways with funnel wire funel wire mesh and 20 mm dia gi pipe medium grade as watering pipe and connected to earthing point complete all as specified and directed. 180 item no 150 : galvanised iron steel tubes, isi marked light grade of size 40mm bore for cable protection along the poles under road under drains complete all as specified and as directed. 181 schedule a ( schedule of credit ) schedule of credit rs 784007.00 ( minus ) inserted by the mes. ( note : credit amount shall be deducted manually to arrive net bid amount ) ...

Bihar Industrial Area Development Authority - Bihar

42981157 request for proposal ( rfp ) for selection of firm / agency / supplier for supply, installation, testing and commissioning of different machines including civil, electrical and other fixtures for setting up food testing lab in upendra maharathi shilp anusandhan sansthan, patna, bihar. 1 highly sensitive triple quadrupole lcms / ms system 2 gas chromatographs with ecd, fid, fpd detector, with headspace and auto sampler ( auto sampler to be provided ) with 5 years consumable and warranty extended upto 5 years 3 gc ms ms with ecd, fid, fpd detector, with headspace and auto sampler ( auto sampler to be provided ) with 5 years consumable and warranty extended upto 5 years 4 icpms accessories and microwave digestion system 5 double beam atomic absorption spectrophotometer 6 high performance liquid chromatography ( gradient ) with uv and fld detector, auto sampler & essential columns with accessories with 5 years consumable and warranty extended upto 5 years 7 uv vis spectrophotometer 8 centrifuge with 5 years consumable and warranty extended upto 5 years 9 ultra low temperature 80 ult freezer 10 ph meter with 5 years consumable and warranty extended upto 5 years 11 elisa reader, filter based plate reader with 5 years consumable and warranty extended upto 5 years 12 heating mantles with 5 years consumable and warranty extended upto 5 years 13 laboratory precision oven uniform temperature 300 o c with 5 years consumable and warranty extended upto 5 years 14 cyclotec lab grinding millwith 5 years consumable and warranty extended upto 5 years 15 magnetic stirrer with 5 years consumable and warranty extended upto 5 years 16 magnetic stirrer with hotplate with 5 years consumable and warranty extended upto 5 years 17 block digestor for eight samples with 5 years consumable and warranty extended upto 5 years 18 moisture analyzer with 5 years consumable and warranty extended upto 5 years 19 muffle furnace 930 degree c with 5 years consumable and warranty extended upto 5 years 20 rectangular hot plate with 5 years consumable and warranty extended upto 5 years 21 refrigerated microcentrifuge with 5 years consumable and warranty extended upto 5 years 22 refrigerators, 2 to 8degreec, capacity 1000l with smart view with 5 years consumable and warranty extended upto 5 years 23 refrigerated incubator orbital shaker ( stackable ) with 5 years consumable and warranty extended upto 5 years 24 soxhlet extraction unit with 5 years consumable and warranty extended upto 5 years 25 nitrogen concentrator ( turbo vap. concentrator ) with 5 years consumable and warranty extended upto 5 years 26 solid phase extraction manifold with 5 years consumable and warranty extended upto 5 years 27 vaccum fitration apparatus along with vaccum pump with 5 years consumable and warranty extended upto 5 years 28 multi tube vortex with mixing, heating, and cooling functions with 5 years consumable and warranty extended upto 5 years 29 analytical weight box, e2 with 5 years consumable and warranty extended upto 5 years 30 analytical weight box, e2, with 5 years consumable and warranty extended upto 5 years 31 analytical balance, 220g x 0.1mg with internal calibration with 5 years consumable and warranty extended upto 5 years 32 microbalance, 5.2g x 0.001mg with internal calibration and static eliminator with 5 years consumable and warranty extended upto 5 years 33 precision balance, 6200g x 0.1 with external calibration with 5 years consumable and warranty extended upto 5 years 34 micro pipette, 30 300 μl, eppendorf with 5 years consumable and warranty extended upto 5 years 35 micropipette, 1 to 10 ml, eppendorf with 5 years consumable and warranty extended upto 5 years 36 micro pipette, 2 to 20 μl, eppendorf with 5 years consumable and warranty extended upto 5 years 37 micro pipette, 10 to 100 μl, eppendorf with 5 years consumable and warranty extended upto 5 years 38 micro pipette, 20 to 200 μl, eppendorf with 5 years consumable and warranty extended upto 5 years 39 micro pipette, 100 to 1000 μl, eppendorf with 5 years consumable and warranty extended upto 5 years 40 rotary vacuum evaporator along with heating bath, diaphragm pump, interface and recirculating chiller rotary evaporator and heating bath with 5 years consumable and warranty extended upto 5 years 41 digital stop watch , 1 real time pcr system with 5 years consumable and warranty extended upto 5 years 2 b.o.d cooling incubators with 5 years consumable and warranty extended upto 5 years 3 vertical laboratory autoclave ( radial locking ) with 5 years consumable and warranty extended upto 5 years 4 laboratory precision oven uniform temperature 300 o c with 5 years consumable and warranty extended upto 5 years 5 horizontal laminar air flow with 5 years consumable and warranty extended upto 5 years 6 digital top pan balance ( 20 gm 800 gm ) , with 5 years consumable and warranty extended up to 5 years 7 analytical balance ( 0.01mg 20 gm ) , with 5 years consumable and warranty extended upto 5 years 8 stability chamber with 5 years consumable and warranty extended upto 5 years 9 biosafety cabinet type ii b, with 5 years consumable and warranty extended upto 5 years 10 deep freezer 20°c, with 5 years consumable and warranty extended upto 5 years olsc 119 12 11 stomacher, with 5 years consumable and warranty extended upto 5 years 12 homogenizer / lab stirrer, with 5 years consumable and warranty extended upto 5 years outer & inner ss 13 ph meter, with 5 years consumable and warranty extended upto 5 years 14 lab grinding mill ( homogenizer ) with 5 years consumable and warranty extended upto 5 years olsc ls 01 15 vortex mixer, with 5 years consumable and warranty extended upto 5 years 16 refrigerated microcentrifuge with 5 years consumable and warranty extended upto 5 years 17 non refrigerated microcentrifuge with 5 years consumable and warranty extended upto 5 years 18 gel documentation system with printer, with 5 years consumable and warranty extended upto 5 years 19 biosafety cabinet type ii b, with 5 years consumable and warranty extended upto 5 years 20 sonicator, with 5 years consumable and warranty extended upto 5 years 21 binocular microscope / 3d microscope, with 5 years consumable and warranty extended upto 5 years 22 uv cabinet, with 5 years consumable and warranty extended upto 5 years 23 serological water bath, with 5 years consumable and warranty extended upto 5 years 24 electronic colony counter with 5 years consumable and warranty extended upto 5 years 1 wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed pvc conduit, with modular type switch, modular plate, suitable size g.i. box and earthing the point with 1.5 sq.mm. fr pvc insulated copper conductor single core cable etc.as required group c 2 wiring for light / power plug with 2x4 sq.mm fr pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit along with 1 no 4 sq.mm. fr pvc insulated copper conductor single core cable for loop earthing as required. 3 wiring for circuit / submain wiring along with earth wire with the following sizes of fr pvc insulated copper conductor, single core cable in surface / recessed pvc conduit as required. 2x2.5 sq.mm +1x2.5 sq.mm 2 x 6 sq.mm + 1 x 6 sq.mm. earth wire 2 x 10 sq.mm. + 1 x 10 sq.mm. earth wire 4 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire 4 x 6 sq. mm + 1 x 6 sq. mm earth wire 4 x 10 sq. mm + 1 x 10 sq. mm earth wire 4 x 16 sq. mm + 1 x 16 sq. mm earth wire 4 supplying and fixing pvc / g.i box of 200mm x 250mm x 60mm deep on surface or in recess with suitable size of phenolic laminated sheet cover in fornt including painting etc as required ( adopter box above each d.b ) . 5 supplying and fixing suitable gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pinm 5 / 6 and 15 / 16 amps modular socket outlet and 15 / 16 amps modular switch, connection, painting etc. as required. ( for power plug ) 6 supplying and fixing suitable size g.i box with modular plate and cover in front on surface in recess including providing and fixing 3 pin, 5 / 6 amps modular socket outlet and 5 / 6 amps modular type switch, connection, painting etc., as required. ( for light plugs to be used in non residential buildings ) 7 supply & fixing 8 way double door sp & n, sheet steel, mcb distribution board, 240 volts, on surface / in recess, complete with tinned copper busbar, neutral link, earth bar, din bar, detachable gland plate, interconnections, phosphatised and powder painted including earthing etc.as required ( but without mcb / rccb / isolator ) lighting db ( a ) 40 amps double pole mcb isolator : 1 no. ( b ) outgoing 6 / 32 amps sp mcb ( b series ) :6 nos. 8 supply & fixing 4 way ( 4+12 ) double door tp & n, sheet steel, mcb distribution board, 415 volts, on surface / in recess, complete with tinned copper busbar, neutral link, earth bar, din bar, detachable gland plate, interconnections, phosphatised and powder painted including earthing etc.as required ( but without mcb / rccb / isolator ) power db ( a ) 63 amps double pole mcb isolator : 1 no. 9 ( b ) outgoing 16 / 32 amps sp mcb ( c series ) : 12 nos. s / f following modular type switch / socket on the existing modular plate and switch box including connection but excluding modular plate etc as required. 10 tv antenna socket outlet 11 s / f electronics musical call bell suitable for d.c / a.c. single phase 230 copmplete as required. 12 supplying and fixing batten / angle holder incluiding connection etc as required. 13 supplying and fixing 2 pin, 5 amp, celling rose on the existing junction box / pvc box incluiding connection etc as required. 14 s / f modular blanking plate on the existing modular plate and switch box excluding modular plate as required. 15 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface / recessed steel / pvc conduit as required. electrical fixture fitting 16 supply and installation of 300 mm 230volt ac exhaust fan in the existing opening including making good the damage connection testing commissioning etc as required. 17 supply & installation 400 mm dia 230 volt ac wall / cabin fan including fixing the bracket making connection testing commissioning etc as required. 18 supply and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver directly on false ceiling including connection with 1.5 sq mm fr insulated copper conductor cable and earthing the body etc as required 19 supplying and fixing indoor recess mounting 36 watt led flat panel luminaire suitable for armstrong / grid ceiling and complete with electronic driver etc. directly on false ceiling including connection with 1.5 sqmm fr pvc insulated copper conductor cable and earthing the body etc as required. 20 supplying and fixing of following types lamp in the existing electrical fitting / fixtures etc. as required. 10 / 12 watt led lamp 21 supplying and fixing 90 watt led type street light with die cast aluminium housing for ingress protection of ip65 and complete with all accessories etc, on pole / building including connection with fr pvc insulated copper conductor cable and earthing the body etc. as required. 22 supplying and fixing following sizes of pvc conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. section 4: fire extinguishers p / f with brackets wall mounted fire extinguishers as per details below: 23 abc power type ( stored pressure ) fire extinuisher 4 kg .capacity , isimark ( is: 15683 ) squeeze gripe valve, operating temperature ( +5 deg. to ( +55 ) deg.for class 3a type of fire with abc powder , complete in all respect. 24 co2 type fire extinguisher 4.5kg capacity isi mark ( is : 15683 ) squeeze grip value , operating temperature ( 30deg. to 55deg.foe class 13b type of fire fitted with 1mt.hose & pvc hoen, complete in all respect. earthing 25 providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required. 26 providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. 27 providing chemical / mineral maintenance free earthing system comprising of copper coated earth electrode 3 metre length and 17.2 mm outer dia along with 25 kg earth conductivity enhancing back fill mineral compound for earth electrode to fill up the excavated earth and earth inspection pit etc. as required. 28 providing and fixing copper tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( for horizontal run ) 29 providing and fixing copper tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( for vertical run ) air condition 30 2 ton inverter cassette ac 5 star inverter ( make: mitsubisi / daikin / toshiba / o general ) noise level indoor ( low / mid2 / mid1 / high ) in db ( a ) not below 45 / 49 / 51.outdoor in not below 54 db ( a ) 31 1.5 ton 5 star inverter split ac ( make: mitsubisi / daikin / toshiba / o general ) noise level indoor ( low / mid2 / mid1 / high ) in db ( a ) not below 45 / 49 / 51.outdoor in not below 54 db ( a ) stablizer ( voltage range: ( 90v to 230 v ) extra copper pipe & electrical wires pvc pipe for drain water fire fighting 32 supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices ( including detectors ) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics / lcd display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory ( eprom ) , power supply unit ( 230± 5% v, 50 hz ) , 48 hrs back up with 24 volt sealed maintenance free batteries with automatic charger. the panel shall have facility to connect printer to printout log and facility to have seamless integration with analog / digital voice evacuation system ( which is part of the schedule of work under sh: pa system ) and shall be complete with all accessories. the panel shall be compatible for ibms system with open protocol bacnet / modbus over ip complete as per specifications. ( edwards est ) 1 loop panel. 1 kva line interactive ups with 30 min battery back up 33 supplying and fixing intelligent addressable type multicriteria detector with base for use as heat or smoke or combined both with automatic electronic addressing, microprocessor type with builtin integrated short circuit isolator including testing, commissiong etc as reqd. 34 supplying and fixing intelligent addressable type heat detector with base with automatic electronic addressing, microprocessor type with builtin integrated short circuit isolator including testing, commissiong etc as reqd. 35 sypplying and fixing intelligent addressable manual call point having inbuilt short circuit isolator i / c testing and commissiong etc as reqd. 36 addressable sounder with interface module, power supply for sonder and programmable by software having integrated short circuit isolator & having operating temperature 10⁰c to + 55⁰c 37 analogue addressable control module with ip66 casing containing four relay outputs, each containing a potential free dpdt contact with a fail safe and in built short circuit isolator the ambient temperature range shall be 20c to +60c. 37 analogue addressable monitor module with ip66 casing containing four relayinputs, each containing a potential free dpdt contact with a fail safe and in built short circuit isolator the ambient temperature range shall be 20c to +60c. duel led response indicator ( local ) 38 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. ( malhotra / anchor ) 20 mm dia 39 supplying & drawing following sizes of fr pvc insulated copper conductor single core cables in existing surface / recessed pvc conduit etc. as complete as required ( polycab / havels ) 2 x 1.5 sq.mm 40 kanex brand abc type fire extinguisher cap. 6 kg filled with mono ammonium phosphate powder 50% confirms to is 4308, stored pressure type, ugts pressure gauge, gross weight 8.9 kg, empty weight 2.9 kg, can height 530 mm, diameter 150 ± 10mm, discharge time 24 sec, controllable discharge mechanism, jet range 5 meters, average discharge is 90%, applicable on class a, b & c and electrically started fire, fire rating 4a:144b, can construction : deep drawn & co2 mig welded, epdm rubber hose with both end aluminum clamped, internal coating epoxy powder coating, external coating pure polyester powder coating ( uv resistant ) , brass forged valves with safety pin is of ss material, sheet metal thickness : 1.8 mm, isi approved is 15683:2018. 41 kanex brand co2 high pressure portable 4.5 kg fire extinguisher, filled with co2 gas as per is 15222, gross weight 16.4, empty weight 11.9 kg, control discharge mechanism fitted with 1 meter wire braided hose & flat horn with diffuser nozzle for dispersed discharge of co2, discharge time 12 sec, average discharge is 95%, applicable on class b, c and electrically started fire, fire rating 55b, internal coating is not applicable & external coating is of enamel spray painting, powder coated handle, squeeze grip type valve confirm to is 3224 isi marked, co2 cylinder construction: hot spinning by seamless pipes & bearing isi mark, body confirms to is 7285 and peso approved, extinguishers confirmed to is 15683:2018 and isi marked. 42 clean agent 2 kg fire extinguishers filled with hfc based gas electrically nonconductive non corrosive, colorless and non residual gas, applicable classes a, b, c, and electrical fires, ugts pressure gauge, gross weight 3.6 kg, empty weight 1.6 kg, height 380mm, diameter 106 ± 10mm, discharge time 12 sec, controllable discharge mechanism, jet range 3 meters, average discharge is 95%, deep drawn with mig welding technology, epdm rubber hose with special aluminum discharge nozzle, external coating pure polyester powder ( uv resistant ) , internal coating epoxy polyester powder, brass forged valves with safety pin is of ss material, fire rating 1a:21b, confirms to is 15683 & isi marked. 43 supplyy, installation, testing & commissioning of 5 lb capacity novec1230 dlp assembly with automatic valve push in connector for tube 5lb novec 1230 gas mounting bracket end linear adopter and low pressure switch for monitoring system activation. : kanex / fire trace 44 supply, installation, testing and commissioning of linear pneumatic heat detection tube with all necessary fitting and supports. ( rotarex / fire trace ) 45 supply, installation, testing & commissioning of audio visual alarm. : kanex / fire trace 46 automatic type 5 kg fire extinguishers hfc 236fa, applicable fire classes a, b & c, ugts pressure gauge, empty weight 2.64 kg, full weight 7.64 kg, can height 375mm, diameter 230 ± 10mm, sheet metal thickness : 2 mm, body construction deep drawn with mig welding technology, brass forged sprinkler valves with nozzle is specially designed to give more than 99% discharge. together with orifice characteristic to cover adequately fire risks with scattering cone of 40 to 45° angle. external pure polyester ( uv resistant ) and internal epoxy polyester powder coated, heat sensitive glass bulb of 68 °c. area covered will be 2 2.5 m2 and volume of coverage is 7 m3. brand : kanex cctv 47 network switch: 24 x 10 / 100 / 1000base t, poe, fixed, 2 x sfp 100 / 1000 mbps, 52 gbps sitching performance capacity, 39 mbps forwarding performance rate. 525 k byte packet buffer, 8k mac address table. 9k bytejumbo frame, 170 watt poe power. 48 bullet camera : 1 / 3 3 megapixel progressive scan cmos, pixels 2304 ( h ) x 1296 ( v ) , electronic shutter speed automanual, 1 / 3 ( 4 ) 1 / 100000s, min illumination 0.1 lux, f1.4 ( color ) ; 0 lux ( ir leds on ) , ir distance upto 100 ft ( 30 m ) , depending upon scene reflectance.day / night auto ( icr ) / color / bw, backlight compensation blc / hlc / dwdr , white balance auto / manual, gain control auto / manual, noise reduction3d, privacy masking upto 4 areas, lens focal length 2.7 12mm, max, aperture f1.4, focus control auto , horizontal angle of view 86 28 degree, lens type motorized focus / zoom, video compression h 264 ( main / high / baseline profile ) / mjpeg, resolution 3 mp ( 2304 x 1296 ) , 1080p ( 1920x1080 ) , 720p ( 1280x720 ) , d1 ( 704x576 / 704x480 ) , cif ( 352x288 / 352x240 ) , frame rate main stream 3 mp ( 1 20 fps ) , 1080p ( 1 25 / 30 fps ) , frame rate 49 dome camera: image sensor 1 / 3 3 magapixel progressive scan cmos, effective pixels 2304 ( h ) x 1296 ( v ) , electronic shutter speed min. illumination 0.045 lux, f2.1 ( color ) , 0 lux ( ir leds on ) , ir distance upto 100 ft ( 30 m ) , depending on scene reflectance, day / night auto ( icr ) / color / bw, backlight compensation blc / hlc / dwdr, white balance, auto / manual, gain control auto / manual, noise reduction 3d, privacy masking upto 4 areas, focal length 2.8mm, max. aperture f2.1, horizontal angle of view 92degree, lens type fixed, video compression h264 ( main / high / baseline profile ) / mjpeg, resolution 3mp ( 2304x1296 ) , 1080p ( 1920x1080 ) , 720p ( 1280x720 ) , d1 ( 704x576 / 704x480 ) 50 video recorder: simultaneous multi channel live view, real time recording, playback, network operation, remote access, usb backup, user interface support 16 bit true color graphical menu interface and mouse operation.preview screen 1 / 4 / 8 / 16 / 24 windows, ip video input 24 channels, video standard pal ( 625 line, 50t / s ) , ntsc ( 525 line, 60t / s ) , video compression h264 high profile, display moitor d1;vga & hdmi, hd ( support 1920x1080, 1280x720, 1440x900, 1260x1024, 1024x768, 800x600 ) 51 display: screen size 42 inch or above ( lg / sony / samsung / philips ) , panel technology ips, aspect ratio 16:9, native resolution 1920x1080 ( fhd ) , brightness 350nit or higher, contrast ratio 1100:1 or higher, dynamic cr 500, 000:1 or higher, viewing angle ( hxv ) 178x178, orientation portrait & landscape, operation temperature 0 degree c to 40 degree c, safety ul, eul, emc fcc class a, ip video unit 16 channel, 1 ch, rca ( 2.0 vp p, 1kohm ) two way audio input, 100 mbps incoming bandwidth, 80 mbps bandwidth, 128 remote connection, hdmi / vga output : 1 ch, resolution hard disk 4 tb camera installation and connectivity telephone 52 epabx with 50 line extension up to 80 line with 2 slt / 2 console the equipment shall be electronic type. it shall have microprocessor / micro controller based.it shall employ pcm / tdm / ip, 100% non blocking, ip digital switching technology.it shall have distributed processing architecture, slic and smt design.system power supply should be in built and smps type which input which input ranges from 90 – 265 vac, 48 60 hz & it has to be battery charger circuit inbuilt, so that, in case of power failure the psu can automatically switch to battery and vice versa. it should be suitable for dtmf as well as fsk type of telephone instruments.its capacity shall be suitable for maximum 96 numbers of c.o. lines, 120 analog extension lines and 500 ip extensions. 53 supply, installation, testing & commissioning of termination box for 50 pair epabx system complete as required 54 base phone cli ( panasonic / beetal ) landline phone with caller id facility corded phone numerical keypad 35 call logs3 display lines disclaimer, tone / pulse switchable ring led indication flash pause dynamic change over from pulse tone, 1 year manufacturer warranty 55 digital console phone 56 network switch : 24 x 10 / 100 / 1000base t, poe, fixed, 2 x sfp 100 / 1000 mbps, 52 gbps sitching performance capacity, 39 mbps forwarding performance rate, 525 k byte packet buffer, 8k mac address table, 9k byte jumbo frame, 170 watt poe power. 57 smart ups on line, 5.4 kw / 6 kva with 1 hour backup12 v 65 ah smf battery ups toplogy double conversion on line, power rating ( va / watts ) 5400watts / 6000va, form factor rack / tower convertible; output power capacity 5400 watts / 6000 va, max configurable power 5400watts / 6000va, nominal output voltage 230v, output voltage note configurable for 220 : 230 or 240 nominal output voltage, efficiency at full load 94.00%, output voltage distortion less than 3%, output frequency ( sync to mains ) 50 / 60 hz + / 3 hz, crest factor 03:01, waveform type sine wave, output connections ( 1 ) *hard wire 3 wire ( 8 ) * ( h n + g ) iec 320 c13 ( 8 ) , bypass built in bypass, output short circuit protection yes, parallel redundancy ( option ) 1 + 1, nominal input voltage 230v, input power factor>0.98, input frequency 40 70hz, input connections terminal block, protection thermal circuit breaker ( 250vac / 20a ) , input voltage range for main operations full load 160 285v, input voltage range for mains operation half load 160 285v, high voltage withstand capability 420 vac, green mode range 210 250 vac ( 230 v ) , battery type mintenance free sealed lead acid battery with suspended, electrolyte. 12v 65 ah smf battery for 60 min battery back up. 58 supplying and drawing following pair 0.5 sq. mm fr pvc insulated annealed copper conductor, unarmoured telephone cable in the existing surface / recessed pvc conduit as required. networking 59 supplying & fixing rj 45 type computer socket suitable for cat 6 on modue gi box along with base and cover plate in surface or in recess including making connection , soldering etc as required. supplying and drawing utp 4 pair cat 6 lan cable patch cord 1 meter patch cord 2 meter 60 24 port gbe smart managed switch with gbe uplink interfaces 24 ports 10 / 100 / 1000mbps+4 sfp;port standards & functions ieee 802.3 10base t ethernet ( twisted pair copper ) , ieee 802.3u 100basetx fast ethernet ( twisted pair copper ) , ieee 802.3ab 1000base t gigabit ethernet ( twisted pair copper ) , ieee 802.3az compliance autonegotiation, ieee 802.3x flow control; full / half duplex full / half duplex for 10 / 100 mbps speeds, full duplex for gigabit speed;media interface exchange auto mdi / mdix adjustment for all twisted pair ports;switching capacity 56 gbps; transmission method store and forward; mac address table 16, 000 entries per device, maximum 64 bytes packet forwarding rate 41.7 mpps, packet buffer memory 1.5 mb, maximum power consumption 22.45 watts, standby power consumption 17.84 w / 240 v, acoustics 0 dba heat dissipation 76.55 btu / hr certifications ce ( lvd ) 61 category 6, utp 24 port patch panel size 482.6mm x 44.2 ( 19’’ x 1u ) , panel material steel fully powder coated, unshielded rj 45, plug insertion cycle 750 times dc resistance 72ω max, voltage rating 72 vdc max, current rating 1.5a max 62 supply fitting fixing rack 19 12u fully powder coated complete etc as required with complete accessories ( 5 amp x 6 socket, wire manager, rack fan ) valrack / netrack make. 63 wireless n access point interface one 10 / 100mbps rj45 port ( auto mdi / mdix ) , button wps button, reset button, external power supply 9vdc / 0.6a, antenna type 5dbi detachable omni directional antenna, frequency 2.4 2.4835ghz, wireless standards ieee 802.11n, ieee 802.11g, ieee 802.11b, wireless security ssid enable / disable mac address filter 64 / 128 / 152 bit wep encryption wpa / wpa2 / wpa psk / wpa2 psk ( aes / tkip ) encryption wireless modes ap mode, multi ssid mode, client mode, repeater mode ( wds / universal ) , bridge mode, tplink / cisco / netgear panel meter board mb 1 incomer 125a, 415v, ics=icu=25ka rupturing capacity, fp, mccb with extended rotary handle 1 no. 1 no. type 1+2 class i+ii lightning surge arrester 3 pole plus neautral. obo make type no. v25 b+c 3npe385 as per item no. 5094478 with mpcb busbar heat shrinked colour coded aluminium bus bars with smc / dmc busbar supports, nuts & bolts with spring washers. a set of tpn 200a al bus bars. current density shall be 1a / sq.mm instrumentation for incoming 1 no. three phase 0 500v digital voltmeter with selector switch 1 no. 0 125a digital ammeter with cts 125 / 5a and selecter witch 1 set of led type phase indicating lamps with hrc fuses meter compartments meter compartments with electonic meters three phase direct type 10 nos. the vendor shall submit details before fabrication outgoings 25 32a fp mcb 12 nos. supply of main l.t. panel fabricated out of 16swg m.s. iron sheets, compartmentalized type, with epoxy powder protective paint having sufficient housing compartpents for mounting of switchgears as per below mentioned specifications, make: kde / scpl / equivalent design, fabrication and supply of suitable electrical grade enclosure, compartmentalized type with epoxy powder protective paint and panel is to be fabricated out of 16swg make: kde / scpl / equivalent supply and installation of 1000 amp of electrolytic aluminium busbar for power load section. supply and installation of proper dmc busbar supporting system suitable for 1000 amp ratings. 250 amp, 35 ka, tpmccb supply of 160amp, 4pole mccb extended rotary handle make: abb / ge / siemens. 25 / 100 amps. 4 pole mccb, 16 ka cable 3.5 core, 300 sq. mm xlpe / pvc insulated sheathed ( heavy duty ) armoured electric cable with aluminium conductor. 3.5 core, 95 sq. mm xlpe / pvc 3.5 core, 150 sq. mm xlpe / pvc 3.5 core, 185 sq. mm xlpe / pvc detailed estimate for the proposed renovation and upgradation work for food test lab at first & 2nd floor, patliputra industrial area, patna. n.s. 1 parking deck flooring with high build, solvent free textured finish epoxy coating with roller applied 5 mm thick epoxy resin based floor coating nitoflor fc150 over epoxy resin screed nitoflor tf 5000 the intended surface shall be prepared by mile scarification to get mechanical key effect to the primer and the concrete surface for ensuring maximum bonding. strong degrease shall be used to remove the oil deposit on the concrete if any. dust and loose particles shall be cleaned using vacuum cleaners . after which nitoprime 25 shall be applied after mixing the base and hardener mechanically using a slow speed heavy duty drilling machine ( 400 to 500 rpm ) fitted with a suitable paddle to achieve homogeneous mix and applied on the prepared surface. after primer nitoflor tf 5000 shall be applied as a base layer after mixing the base hardener and aggregates throughly and poured on the primed surface and spread evenly to maintain the required thickness of 3 mm. the material should be tampered with a wooden float to ensure complete compaction and finally finished to closed even texture using a steel trowel and cured for seven days. as a finishing coat nitoflor fc 150 shall be applied over the screed surface after mixing mechanically the three components using heavy duty slow speed paddle mixer until achieving a homogeneous mix and spread on the prepared area using medium haired rol;ler for a thickness of 400 microns in two coat. 8.2 providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters facias and similar locations of required size of approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement: 4 coarse sand ) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing etc. complete at all levels. 8.2.2 granite of any colour and shade 8.2.2.2 area of slab over 0.50 sqm 8.3 extra for providing edge moulding to 19 mm thick marble stone counters, vanities etc. over item no. 8.2 mm thick marble stone counters, vanities etc. over item no. 8.2 including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer in charge. granite work 8.3.2 granite work 26.27 providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ≥85%, thermal conductivity k=0.057 w / m k, fire performance as per ( bs 476 pt 6 & 7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanised iron section of 0.33mm thick ( galvanized @120gsm ) comprising of main t runners of 15x32mm of length 3000mm, cross t of size15x32mm of length 1200mm and secondary intermediate cross t of size 15x32mm of length600mm to form grid module of size 600x600mm suspended from ceiling using galvanized mild steel item ( galvanised @80gsm ) 50mm long 8mm outer diameter m 6 dash fasteners, 6mm diameter fully threaded hanger rod upto 1000mm length and l shape level adjuster of size 85x25x2mm, spaced at 1200mm centre to centre along main t. the system should rest on periphery walls / partitions with the help of gi perimeter wall angle of size 24x24x3000mm made of 0.40 mm thick sheet, to be fixed to the wall with the help of plastic rawl plug at 450mm centre to centre & 40mm long dry wall s.s. screws. the exposed bottom portion of all t sections used in false ceiling support system shall be prepainted with polyester baked paint, for all heights. the work shall be carried out as per specifications, drawings and as per directions of the engineer in charge. 26.27.2 with 20mm thick beveled tegular mineral fibre false ceiling tile ( nrc0.7 ) . 12.45.3 providing and fixing false ceiling at all height including providing and fixing of frame work made up of special sections power pressed from m.s. sheet and galvanized in accordance with zinc coating of 120 gms / sqm as per is:277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm at 1200 mm centre to centre one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts to the angle hanger of 25x25x5 mm of required length, and other end of angle hanger being fixed with nut and bolts to g.i. channels 45x15x0.9 mm running at the rate of 1200 mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having clips of 10.5 mm centre to centre shall be fixed in a direction perpendicular to g.i. channel with connection clips made out of 2.64 mm dia x 230 mm long g.i. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall / partition with the help of rawl plugs at 450 mm centre to centre with 25 mm long drive all screws @230 mm interval including jointing and fixing to a flush finish of tapered and square edges of the gypsum board with recommended filler, paper tapes, finishers and two coats of primer suitable for gypsum board as per manufacturers specification and also including the coat of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per the drawing and specification and direction of the the engineer in charge but excluding the cost of painting. 12.5 mm thick tapered edge gypsum moisture resistant board 12.62 extra for any sunk or raised moulding in the plaster of paris ( gypsum anhydrous ) ceilng .all complete as per specification and direction of e / i. ns 2 supplying fitting and fixing roman blinds in jacard cloth finish as per company specification and as per approved colour and sample inclusive of all taxes and royalty all complete as per specifications / approval and direction of engineer in charge. n.s. 3 providing & fixing double skin laminated both side wpc partition upto specified height with 1.0 mm lamination of greenply / marino / century mica over 12 mm thick wpc of alstone / greenply / century ( min wt. 550kg / cum ) make fitted and fixed both sides over aluminium frame of 50 x 50mm posts at 60 cm centres and 50x50mm horizontal members at approx 60 cm centers including cost of anchoring the partition to floors, walls and ceiling properly as per drawing including making hidden doors as per drawing all complete as per drawing, specifications and direction of e / i. providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of engineer in charge ( door handle , lock, and stopper etc . n.s 4 supplying fitting and fixing glass door handles, h type ( qbghl 5 ) made up of stainless steel brushed steel finish 300 mm heigh / equivalent make all complete including taxes and royalty as per approval and direction of e / i. n.s 5 supplying fixing and fitting high security corner lock for patch fitting ( qbpl 1 make ) brushed steel finish made of graded aluminium alloy cast housing slim and compact size light in weight all complete as per specification and direction of e / i ns 6 providing and fixing of 1.0mm laminated ( greenlam / century / merino ) panelling upto specified height over 12 mm thick wpc board of alstone / greenply / century make fitted and fixed over aluminium frame of 25 x 25mm posts at 30 cm centres and 25 x 25mm horizontal members at approx 30 cm centers including cost of anchoring the panelling to walls properly including termite treatment as per drawing specification and direction of e / i. 14.1.1 repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground, all complete as per direction of e / i. cement mortar 1:4. 13.74 removing white or colour wash by scraping and sand papering and preparing the surface smooth including necessary repair scratches etc. complete 13.80 a.2 providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 13.92 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade. 13.92.1 two or more coat on new surface. 9.48 providing and fixing m.s grills of required pattern in frames of windows etc. with m.s flats, square or round bars etc. all comlete. 9.48.1 fixed to steel windows by welding. 13.94 painting with sythetic enamel paint of approved brand and manufacture to give an even shade. 13.94.1 two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. 15.23 dismantling tile works in floor and roofs laid in cement mortar including stacking material within 50 metres lead. 15.23.2 for thickness of tiles above 25 mm and upto 40 mm 15.7 demolishing brick work including stacking of serviceable material and disposal of unserviceable materials within 50 metres lead : 15.7.4 in cement mortar disposal of building rubbish / malba / similar unserviceable, dismantled or waste waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by engineer in charge, beyond 50 m initial section 3: electrical work s.h. i : wiring 1.3.3 point wiring in pvc conduit, with modular type switch: wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq mm fr pvc insulated copper conductor single core cable in surface / recessed pvc conduit, with modular switch, modular plate, suitable g.i. box etc. as required. group c 1.4 twin control point wiring in pvc conduit with modular type switch: wiring for twin control light point with 1.5 sq mm fr pvc insulated copper conductor single core cable in surface / recessed pvc conduit, 2 way modular switch, modular plate, suitable g.i. box etc. as required. 1.5 power plug wiring in pvc conduit ( 2x4 sq. mm ) : wiring for light / power plug with 2 x 4 sq. mm fr pvc insulated copper conductor single core cable in surface / recessed pvc conduit alongwith 1 no. 4 sq. mm fr pvc insulated copper conductor singlre core cable for loop earthing as required. ( for 15 amp socket ) 1.7 circuit / sub main wiring in pvc conduit : wiring for circuit / submain wiring alongwith earthwire with the following sizes of pvc insulated copper conductor, singlre core cable in surface / recessed pvc conduit as required. 1.7.1 2 x 1.5 sq.mm. + 1 x 1.5 sq. mm earth wire 1.7.2 2 x 2.5 sq.mm. + 1 x 2.5 sq. mm earth wire 40185 4 x 4 sq.mm. + 1 x 4 sq. mm earth wire 40550 4x 6 sq.mm. + 1 x 6 sq. mm earth wire 1.16 telephone wiring in existing conduit: supplying and drawing following pair, 0.5 sq. mm fr pvc insulated copper conductor, unarmoured telephone cables in existing surface / recessed pvc conduit as required 1.16.2 2 pair 1.21 s / f pvc conduit: supplying and fixing of following sizes of pvc conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recess conduit as required. 1.21.1 20 mm 1.24 s / f modular type switch / socket : supplying and fixing following modular type switch / socket on the existing modular switch / socketon the existing modular plate& switch box including connections but excluding modular plate etc. as required. 1.24.4 3 pin, 5 / 6 amps socket outlet 1.24.5 6 pin, 15 / 16 amps socket outlet 1.24.6 telephone socket outlet 1.24.8 bell push 1.27.1 s / f modular boxes, base & cover plate: supplying and fixing following size / modules, gi box along with modular base & cover plate for modular switches in recess as required. 1 or 2 module ( 75 mm x 75 mm ) 1.31 s / f light plug point modular type accessories: supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5 / 6 amps modular socket outlet and 5 / 6 amps modular switch, connection, painting etc. as required. ( for light plugs to be used in non residential buildings. ) 1.32 s / f power plug point modular type accessories: supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5 / 6 & 15 / 16 amps modular socket outlet and 15 / 16 amps modular switch, connection, painting etc. as required. 5.4 supplying and fixing replaceable compact commercial batten suitable for single tb led tube complete with 20 watt led polycarbonate tb tube with built in driver etc. directly on wall / ceiling including connections with 1.5 sq. mm fr pvc insulated copper conductor etc. as required. 1.37 providing and fixing ding dong call bell suitable for single phase, 230 volts complete as required. 8.15 supply and installation of regular / standard model a.c. ceiling fan of 1200 mm sweep with service value ( cm / mm ) minimum 4.00, air delivery minimum 270 cum / min including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq mm fr pvc insulated copper conductor etc as required. 5.7 supplying and fixing recess mounted following types led downlighter with minimum efficacy 100 lm / w in pressure die cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm frls pvc insulated copper conductor cable etc as required. 5.7.1 5 / 7 watt 5.7.5 18 watt 5.9 supplying and fixing recess mounted 36 watt led flat panel ( 2 x 2 ) with minimum efficacy 100 lm / w which provides soft light and glare free symmetrical illumination suitable for armstrong / grid ceiling and integrated electronic driver etcdirectly on false ceiling including connections with 1.5 sq.mm frls pvc insulated copper conductor cable etc as required. 5.11 supplying and fixing wall mounted light bracket / fixture made with polycarbonate suitable for single 9 / 10 watt led lamp directly on wall including connections etc as required. ( but without lamp ) 6.1.6 supplying and fixing of following types lamp in the existing electrical fitting / fixtures etc. as required. 14 / 15 watt cfl lamp. 2.12 s / f c series, sp mcb: supplying and fixing following rating, 240 / 415 volts, c curve, miniature circuit breaker, suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 2.12.1 6 / 32 amps, single pole 2.12.2 6 / 32 amps, spn 2.12.4 6 / 32 amps, triple pole and neutral 2.12.8 40 amps, triple pole and neutral 2.19 supplying and fixing 20amp 240 volts spn mcb industrial type, power socket with 25amp spn mcb and 25 amps top in proper size steel box and plate as required. all complete as per instructions of elec.er. / architect. 8.11 supply and fixing of fabricated electrical control panel of cubical construction, floor / wall mounted type, fabricated out of 16 swg crca sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, bus bar chamber, insulator and complete in all respect etc and panel manufactures must be approved by cpri. ( but without ryb inicator, ammeter, voltmeter, inter connection copper conductor cable / solid copper strip, switchgears etc. ) ...

Uttar Pradesh Projects Corporation Limited - Bihar

42836281 construction of phase b works at jnv madhubani ( bihar ) 1 guest house ( civil works ) 2 earth work 3 earth work in excavation by mechanical means ( hydraulic excavator ) / manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 sqm on plan ) , including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 4 all kinds of soil 5 filling available excavated earth ( excluding rock ) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 6 supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 7 excavating, supplying and filling of local earth ( including royalty ) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 8 concrete work 9 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 10 1:5:10 ( 1 cement : 5 coarse sand ( zone iii ) : 10 graded stone aggregate 40 mm nominal size ) 11 providing and laying cement concrete in retaining walls, return walls, walls ( any thickness ) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : 12 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) . 13 providing and laying damp proof course 40mm thick with cement concrete 1:2:4 ( 1 cement : 2 coarse sand ( zone iii ) : 4 graded stone aggregate 12.5mm nominal size ) 14 providing & applying a coat of residual petroleum bitumen of grade of vg 10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 15 making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 16 reinforcedcementconcrete 17 centering and shuttering including strutting, propping etc. and removal of form for all heights: 18 foundations, footings, bases of columns, etc. for mass concrete 19 columns, pillars, piers, abutments, posts and struts 20 small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like 21 edges of slabs and breaks in floors and walls 22 under 20 cms wide 23 suspended floors, roofs, landings, balconies and access platform. 24 lintels, beams, plinth beams, girders, bressumers and cantilevers. 25 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 26 thermo mechanically treated bars of grade fe 500d or more. 27 add for plaster drip course / groove in plastered surface or moulding to r.c.c. projections. 28 providing and laying in position machine batched and machine mixed design mix m 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per is: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of engineer in charge.“ ( note : cement content considered in this item is @ 330 kg / cum.“excess / less cement used as per design mix is payable / recoverable separately ) . 29 all works upto plinth level 30 all works above plinth level upto floor v level 31 brick work 32 brick work with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 in foundation and plinth in: 33 cement mortar 1:6 ( 1 cement : 6 coarse sand ) 34 providing and laying autoclaved aerated cement blocks masonry with 150mm / 230mm / 300 mm thick aac blocks in super structure above plinth level up to floor v level with rcc band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of engineer in charge. ( the payment of rcc band and reinforcement shall be made for seperately ) . 35 half brick masonry with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 in superstructure above plinth level up to floor v level. 36 cement mortar 1:4 ( 1 cement :4 coarse sand ) 37 extra for providing and placing in position 2 nos 6mm dia. m.s. bars at every third course of half brick masonry. 38 brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 including grouting with cement mortar 1:4 ( 1 cement : 4 fine sand ) . 39 marble work 40 providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand ) , joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 41 granite of any colour and shade 42 area of slab over 0.50 sqm 43 providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer in charge. 44 granite work 45 extra for fixing marble / granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. 46 extra for providing opening of required size & shape for wash basin / kitchen sink in kitchen platform, vanity counter and similar location in marble / granite / stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 47 wood work & pvc work 48 providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately ) . 49 second class teak wood 50 extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. ( area of opening for glass panes excluding portion inside rebate shall be measured ) . 51 providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 52 25 mm thick ( for cupboard ) including isi marked nickel plated bright finished m.s. piano hinges is : 3818 marked with necessary screws 53 providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) non decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 54 35 mm thick including isi marked stainless steel butt hinges with necessary screws 55 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters ( over all area of door shutter to be measured ) . 56 providing and fixing wire gauge shutters using galvanized m.s. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 57 35 mm thick shutters 58 kiln seasoned and chemically treated hollock wood 59 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coat with approved steel primer all complete. 60 fixed to steel windows by welding 61 providing and fixing fly proof galvanized m.s. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. 62 with 12 mm mild steel u beading 63 providing and fixing oxidised m.s. casement stays ( straight peg type ) with necessary screws etc. complete. 64 250 mm weighing not less than 150 gms 65 providing and fixing aluminium sliding door bolts, isi marked anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) , transparent or dyed to required colour or shade, with nuts and screws etc. complete : 66 250x16 mm 67 providing and fixing aluminium tower bolts, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 68 200x10 mm 69 providing and fixing aluminium handles, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 70 125 mm 71 providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. 72 twin rubber stopper 73 providing & fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to is : 2046 type s, including cost of adhesive of approved quality. 74 1.5 mm thick 75 providing and fixing cup board shutters with 25 mm thick veneered particle board is : 3097 marked, exterior grade ( grade i ) , of approved make, including iind class teak wood lipping of 25 mm wide x 12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of engineer in charge. 76 with decorative veneering on one side and commercial veneering on other side 77 providing and fixing factory made upvc white colour sliding glazed window upto 1.50 m in height dimension comprising of upvc multi chambered frame with in built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length ( shape & size according to upvc profile ) , appropriate dimension of upvc extruded glazing beads and upvc extruded interlocks, epdm gasket, wool pile, zinc alloy ( white powder coated ) touch locks with hook, zinc alloy body with single nylon rollers ( weight bearing capacity to be 40 kg ) , g.i fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of engineer in charge. ( single / double glass panes, wire mesh and silicon sealent shall be paid separately ) . variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 78 three track three panels sliding window with fly proof s.s wire mesh ( two nos. glazed & one no. wire mesh panels ) made of ( big series ) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. ( area of window above 1.75 sqm ) . 79 providing and fixing isi marked oxidised m.s. single acting spring hingeswith necessary screws etc. complete : 80 150 mm 81 providing and fixing oxidised m.s. hasp and staple ( safety type ) conforming to is : 363 with necessary screws etc. complete : 82 90 mm 83 providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 84 75 mm 85 providing and fixing wooden moulded corner beading of triangular shape to the junction of panelling etc. with iron screws, plugs and priming coat on unexposed surface etc. complete 2nd class teak wood. 86 50x50 mm ( base and height ) 87 float glass panes 88 4.0 mm thick glass panes ( weight not less than 10 kg / sqm ) . 89 steel work 90 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side / top / centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, ( sectional weight of only steel members shall be measured for payment ) . 91 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) 92 providing and fixing t iron frames for doors, windows and ventilators of mild steel tee sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 93 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) 94 providing and fixing circular / hexagonal cast iron or m.s. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick m.s. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron / m.s. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. clamp shall be made of 12 mm dia m.s. bar bent to shape as per standard drawing. 95 providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 96 4.0 mm thick glass panes 97 flooring 98 kota stone slab flooring over 20 mm ( average ) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 ( 1 cement : 4 coarse sand ) : 99 25 mm thick. 100 providing and fixing glass strips in joints of terrazo / cement concrete floors. 101 40 mm wide and 4 mm thick 102 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm ( average ) thick cement mortar 1:3 ( 1 cement: 3 coarse sand ) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 103 extra for pre finished nosing in treads of steps of kota stone / sand stone slab. 104 extra for kota stone / sand stone in treads of steps and risers using single length up to 1.05 metre. 105 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 106 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3kg / sqm including pointing the joints with white cement and matching pigment etc., complete. 107 providing and laying vitrified floor tiles in different sizes ( thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3kg / sqm including grouting the joints with white cement and matching pigments etc., complete. 108 size of tile 600x600 mm 109 providing and laying vitrified tiles in different sizes ( thickness to be specified by manufacturer ) , with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 ( 1 cement: 3 coarse sand ) , jointing with grey cement slurry @ 3.3kg / sqm including grouting the joint with white cement & matching pigments etc. complete. 110 size of tile 600x600 mm 111 roofing 112 providing and laying brick tiles over mumty roofs, grouted with cement mortar 1:3 ( 1 cement : 3 fine sand ) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 ( 1 cement : 3 fine sand ) and finished neat. 113 with common burnt clay f.p.s. ( non modular ) brick tilesof class designation 10 114 making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size ) over p.v.c. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 ( 1 cement : 3 coarse sand ) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 115 finishing 116 12 mm cement plaster of mix 117 1:6 ( 1 cement: 6 coarse sand ) 118 15 mm cement plaster on rough side of single or half brick wall of mix: 119 1:6 ( 1 cement: 6 coarse sand ) 120 cement plaster 1:3 ( 1 cement: 3 coarse sand ) finished with a floating coat of neat cement. 121 20 mm cement plaster 122 6mm cement plaster of mix 123 1:3 ( 1 cement : 3 fine sand ) 124 white washing with lime to give an even shade : 125 new work ( three or more coats ) 126 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 127 new work ( two or more coats ) over and including water thinnable priming coat with cement primer 128 finishing walls with premium acrylic smooth exterior paint withsilicone additives of required shade: 129 new work ( two or more coats applied @ 1.43 ltr / 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm ) 130 applying priming coat: 131 with ready mixed pink or grey primer of approved brand and manufacture on wood work ( hard and soft wood ) 132 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron / steel works 133 painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 134 two or more coats on new work 135 painting with black anti corrosive bitumastic paint of approved brand and manufacture to give an even shade : 136 two or more coats on new work 137 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 138 water proofing 139 providing and laying in situ seven course water proofing treatment with app ( atactic poly propylene ) modified polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 kg / sqm, which shall consist of blown type bitumen of grade 85 / 25 conforming to is : 702, 3rd and 5th layers of roofing membrane app modified polymeric membrane 1.5 mm thick of 2.25 kg / sqm weight consisting of five layers prefabricated with centre core as 20 micron hmhdpe film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron hmhdpe film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 ( 1cement : 3 fine sand ) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 ( 1 cement : 3 fine sand ) and finished neat ( item of laying brick tiles shall be paid for separately ) . 140 providing and laying brick tiles over mumty roofs, grouted with cement mortar 1:3 ( 1 cement : 3 fine sand ) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 ( 1 cement : 3 fine sand ) and finished neat: 12.19.1 with common burnt clay f.p.s. ( non modular ) brick tilesof class designation 10 141 earth work 142 earth work in excavation by mechanical means ( hydraulic excavator ) / manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 sqm on plan ) , including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 143 all kinds of soil. 144 excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 145 all kinds of soil 146 pipes, cables etc, not exceeding 80 mm dia. 147 pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 148 filling available excavated earth ( excluding rock ) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 149 roofing 150 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, ( i ) single socketed pipes. 151 110 mm diameter 152 providing and fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 153 coupler 154 110 mm 155 bend 87.5° 156 110 mm bend 157 shoe ( plain ) 158 110 mm shoe 159 providing and fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with m.s. screws of required length, including cutting brick work and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand ) and making good the wall etc. complete. 160 110 mm 161 providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 162 sanitary installations 163 providing and fixing water closet squatting pan ( indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 164 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 165 providing and fixing wash basin with c.i. brackets, 15 mm c.p. brass pillar taps, 32 mm c.p. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 166 white vitreous china flat back wash basin size 550x 400 mm with single 15 mm c.p. brass pillar tap 167 providing and fixing stainless steel a isi 304 ( 18 / 8 ) kitchen sink as per is: 13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 168 kitchen sink with drain board 169 510x1040 mm bowl depth 250 mm 170 extra for using coloured pedestal type w.c pan ( european type ) with low level cistern of same colour instead of white vitreous china w.c pan and cistern. 171 providing and fixing 600x450 mm beveled edge mirror of superior glass ( of approved quality ) complete with 6 mm thick hard board ground fixed to wooden cleats with c.p. brass screws and washers complete. 172 providing and fixing toilet paper holder : 173 vitreous china 174 providing and fixing soil, waste and vent pipes : 175 100 mm dia. 176 centrifugally cast ( spun ) iron socket & spigot ( s&s ) pipe as per is: 3989 177 75mm diameter 178 centrifugally cast ( spun ) iron socketed pipe as per is: 3989 179 providing and fixing m.s. holder bat clamps of approved design to sand cast iron / cast iron ( spun ) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) , including cost of cutting holes and making good the walls etc. : 180 for 100 mm dia. pipe 181 for 75 mm dia. pipe 182 providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 183 100 mm 184 sand cast iron s&s as per is 3989 185 75 mm 186 sand cast iron s&s as per is 3989 187 providing and fixing plain bend of required degree. 188 100 mm 189 sand cast iron s&s as per is : 3989 190 75 mm 191 sand cast iron s&s as per is 3989 192 providing and fixing heel rest sanitary bend 193 100 mmdia 194 sand cast iron s&s as per is 3989 195 75 mm dia 196 sand cast iron s&s as per is 3989 197 providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 198 100x100x100mm 199 sand cast iron s&s as per is 3989 200 75x75x75mm 201 sand cast iron s&s as per is 3989 202 providing and fixing single equal plain junction of required degree 203 100x100x100mm 204 sand cast iron s&s as per is 3989 205 75x75x75mm 206 sand cast iron s&s as per is 3989 207 providing and fixing door piece, insertion rubber washer 3mm thick, bolts & nuts complete : 208 100 mm 209 sand cast iron s&s as per is 3989 210 75 mm 211 sand cast iron s&s as per is 3989 212 providing and fixing terminal guard : 213 100 mm 214 sand cast iron s&s as per is 3989 215 75 mm 216 sand cast iron s&s as per is 3989 217 providing and fixing collar : 218 100 mm 219 sand cast iron s&s as per is 3989 220 75 mm 221 sand cast iron s&s as per is 3989 222 providing lead caulked joints to sand cast iron / centrifugally cast ( spun ) iron pipes and fittings of diameter : 223 100 mm 224 75 mm 225 providing and fixing m.s. stays and clamps for sand cast iron / centrifugally cast ( spun ) iron pipes of diameter : 226 100 mm 227 75 mm 228 providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 229 100 mm inlet and 100 mm outlet 230 sand cast iron s&s as per is: 1729 231 cutting chases in brick masonry walls for following diameter sand cast iron / centrifugally cast ( spun ) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size ) , including necessary plaster and pointing in cement mortar 1:4 ( 1 cement : 4 coarse sand ) : 232 100 mm dia 233 painting sand cast iron / centrifugally cast ( spun ) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer ( of approved quality ) for new work : 234 100 mm diameter pipe 235 75 mm diameter pipe 236 providing and fixing ptmt waste coupling for wash basin and sink, of approved quality and colour. 237 waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms 238 providing and fixing ptmt bottle trap for wash basin and sink. 239 bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms 240 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 241 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour. 242 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 243 providing and fixing g.i. pipes complete with g.i. fittings including trenching & refilling. 244 external work 245 32mmdia nominal bore 246 40mmdia nominal bore 247 50mmdia nominal bore 248 water supply 249 providing and fixing chlorinated polyvinyl chloride ( cpvc ) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 250 internal work exposed on wall 251 25 mm nominal outer dia pipes metre 252 32 mm nominal outer dia pipes metre 253 providing and fixing chlorinated polyvinyl chloride ( cpvc ) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i / c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 254 concealed work, including cutting chases and making good the walls etc. 255 15 mm nominal outer dia pipes 256 20 mm nominal outer dia pipes 257 making connection of g.i. distribution branch with g.i. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 258 25 to 40 mm nominal bore 259 providing and fixing brass stop cock of approved quality : 260 15 mm nominal bore 261 20 mm nominal bore 262 providing and fixing gun metal gate valve with c.i. wheel of approved quality ( screwed end ) : 263 25mm nominal bore 264 32mm nominal bore 265 40mm nominal bore 266 providing and fixing ball valve ( brass ) of approved quality, high or low pressure, with plastic floats complete : 267 25 mm nominal bore 268 providing and fixing brass ferrule with c.i. mouth cover including boring and tapping the main : 269 25 mm nominal bore 270 providing and fixing uplasticised pvc connection pipe with brass unions : 271 45 cm length 272 15 mm nominal bore 273 providing and fixing c.p. brass shower rose with 15 or 20 mm inlet : 274 100 mm diameter 275 providing and placing on terrace ( at all floor levels ) polyethylene water storage tank, is : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 276 rectangular tank 277 providing and fixing c.p. brass bib cock of approved quality conforming to is:8931 : 278 15 mm nominal bore 279 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 280 15 mm nominal bore 281 providing and fixing c.p. brass stop cock ( concealed ) of standard design and of approved make conforming to is:8931. 282 15 mm nominal bore. 283 providing and fixing c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 284 15 mm nominal bore 285 providing and fixing ptmt grating of approved quality and colour. 286 circular type. 287 100 mm nominal dia. 288 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) , including finishing complete so as to make it leak proof. 289 sewarage & drainage 290 providing, laying and jointing glazed stoneware pipes class sp 1 with stiff mixture of cement mortar in the proportion of 1:1 ( 1 cement : 1 fine sand ) including testing of joints etc. complete : 291 100 mm diameter 292 150 mm diameter 293 providing and laying cement concrete 1:5:10 ( 1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size ) all round s.w. pipes including bed concrete as per standard design : 294 100 mm diameter s.w. pipe 295 150 mm diameter s.w. pipe 296 providing and fixing square mouth s.w. gully trap class sp 1 complete with c.i. grating brick masonry chamber with water tight c.i. cover with frame of 300 x300 mm size ( inside ) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70kg as per standard design: 297 150 x 100 mm size p type 298 with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 299 constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with r.c.c. top slab with 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) , foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size ) , inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand ) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design : 300 inside size 90x80 cm and 45 cm deep including c.i. cover with frame ( light duty ) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg ( weight of cover 23 kg and weight of frame 15 kg ) : 301 with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 302 extra for depth for manholes : 303 size 90x80 cm 304 with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 305 providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per is : 10910, on 12 mm dia steel bar conforming to is: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) complete as per design. 306 making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) cement plastered on both sides with cement mortar 1:3 ( 1 cement : 3 coarse sand ) , finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 307 for pipes 100 to 250 mm diameter 308 providing, laying and jointing non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete : 309 150 mm dia rcc pipe 310 non shedule items 311 providing and fixing floor drain points of 75 x 50mmreducer bend with 100 mm dia cp grating with frame, embedded in floor including making joints with waste pipe etc. complete in all respects as per drawing and as directed by theengineer in charge. 312 providing & fixing sink mixer with swinging casted spout ( wall mounted jaquar model con 309 kn ) / approved equal with 450mm long copper pipes & brass nuts. 313 providing and fixing concealed single leverbath & overhead shower mixer of hindware make and model no. ( f360019cp ) respectively or equivalent approved make as approved byengineer in charge. 314 supplying, fixing, testing and commissioning of storage type water heater ( geyser ) etc. with stainless steel body , copper container , automatic thermostatic control electric element, pressure release valve, m.s. nuts and bolts etc. conforming to is: 2082 315 25 litre capacity 316 ( electrical works ) 317 subhead i wiring 318 wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. 319 group c 320 wiring for light / power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 321 supplying and fixing following size / modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 322 4 module ( 125 mmx75 mm ) 323 supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 324 15 / 16 a switch 325 3 pin 5 / 6 a socket outlet 326 telephone socket outlet 327 tv antenna socket outlet 328 wiring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed steel conduit as required. 329 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire 330 2 x 10 sq. mm + 1 x 6 sq. mm earth wire 331 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface / recessed steel / pvc conduit as required. 332 supplying and fixing of following sizes of steel conduit along with accessories in surface / recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 333 25 mm 334 supplying and fixing following size / modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 335 1 or 2 module ( 75 mmx75 mm ) 336 supplying and drawing following pair 0.5 mm dia frls pvc insulated annealed copper conductor, unarmored telephone cable in the existing surface / recessed steel / pvc conduit as required. 337 2 pair 338 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. 339 20 mm 340 25 mm 341 providing and fixing in position 2mm thick m.s. telephone junction box of size suitable for fixing of following krone tag block with key lock arrangement. also provide clamps for fixing tag blocks. 342 10 pair telephone tag blockwith box 343 supplying, laying of 10 pair unarmoured pvc insulated copper conductor ( atc ) telephone cable in ground / existing pipes / on wall and making connection with telephone main junction box ( mdf ) including supports and all accessories as required 344 10 pair cable unarmoured 345 subhead ii supply & installation of fittings 346 supplying of following box type fl. fitting made out of crca sheet finished in antirust treated non yellowing super white stove enamelled paint duly wired with copper wound heavy duty choke starter holder, starter but without lamp complete etc. as reqd. 347 mounting rail for tled lamps 1600 lumens ( tmc 501 p 1xt led with essential led 18w tube ) 348 supplying of wall bracket light fittings suitable for 11 / 13 w cfl lamp. the fitting shall be made up of m.s. powder coated provided with integral ballast, frosted glass and 1 no. 11 / 13 wlamp duly wired upto the connector block complete as required. ( decon cat. no.05aam ) 349 supplying of ceiling light fittings suitable for 1 x 15 / 20 w led lamp. the fitting shall be made up of m.s. powder coated provided with electronic ballast, 1 no. 15 / 20 w led lamp duly wired upto the connector block etc. complete as required. 350 cirrus mini pro 15 / 20 watt & 1100 / 1600 lumens ( philips sm200c led11s 6500 psu od wh ) 351 supplying of bulk head fittings suitable for 10 w led lamp complete with ballast & accessories such as glass, wire guard, 60 w cfl lamp etc. complete as required. 352 endural led bulkhead, 10 w, 600 lumen such as ( philips wt202w led6s cw psu s2 pc ) 353 supplying of exhaustfan, all complete with mounting ring frame i / c bracket, but without regulator with shutters in the following sizes. ( g.e. alsthom, khaitan & havells company ) 354 300 mm 4 pole 355 supplying of 1400 mm sweep a.c. electric ceiling fans, capacitor type with double ball bearing complete with 300 mm down rod, canopies, shackles, blades, but without regulator suitable for operation on 230 / 240 volts, 50 hz, single phase, a.c. supply. ( crompton, khaitan & havells company ) 356 supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 357 installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 358 installation, testing and commissioning of pre wired, light fixture / compact fluorescent fitting of all types, complete with all accessories and tube / lamp etc. directly on ceiling / wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 359 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 360 upto 450 mm sweep 361 extra for fixing the louvers / shutters complete with frame for a exhaust fan of all sizes. 362 installation, testing and commissioning of wall bracket / ceiling fittings of all sizes and shapes containing upto two gls / cfl / led lamps per fitting, complete with all accessories including connections etc. as required. 363 supplying and fixing call bell / buzzer suitable for single phase, 230 v, complete as required. 364 subhead iii distribution board 365 supplying, installing, testing and commissioning of compartmentalised cubical type meter board for installation of single phase meter. the cubical board shall be made of 2mm thick c.r.c.a sheet, duly phosphatised powder coated complete with connection bus bar and following accessories mounted in it. 366 meter board 367 incoming : 368 40a tp mccb having breaking capacity 25 ka 1 no. 369 outgoing : 370 space for single phase energy meter 4 nos. 371 25 amp dp mcb 4 nos. 372 supplying, installing, testing & commissioning of single phase electronic energy meter, tested as per electricity boards requirement. 373 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 374 12 way, spn 375 supplying and fixing following rating, double pole, 240 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 376 40 amps 377 supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. asrequired. 378 25 amps 379 supplying of xlpe insulated, pvc sheathed 1.1 kv grade aluminium conductor heavy duty armoured cable as per is : 7098 of size : 380 4 x 16 sq.mm. 381 providing, laying and fixing following dia rcc pipe np2 class ( light duty ) in ground complete with rcc collars, jointing with cement mortar 1:2 ( 1 cement : 2 fine sand ) including trenching ( 75 cm deep ) and refilling etc. as required for crossing road / walls 382 100 mm dia 383 supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 384 single pole 385 subhead iv earthing 386 earthing with g.i. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. 387 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re filling as required. 388 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 389 staff quarters type iii 390 earth work 391 earth work in excavation by mechanical means ( hydraulic excavator ) / manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 sqm on plan ) , including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 392 all kinds of soil 393 filling available excavated earth ( excluding rock ) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 394 supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 395 supplying chemical emulsion in sealed containers including delivery as specified. 396 chlorpyriphos / lindane emulsifiable concentrate of 20% 397 diluting and injecting chemical emulsion for post constructional anti termite treatment ( excluding the cost of chemical emulsion ) : 398 treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 ( 1 cement : 2 coarse sand ) to match the existing floor: 399 with chlorpyriphos / lindane e.c. 20% with 1% concentration 400 excavating, supplying and filling of local earth ( including royalty ) by mechanical transport upto a lead of 5km also includingramming and watering of the earth in layers not exceeding 20cm in trenches, plinth, sides of foundation etc. complete. 401 concrete work 402 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 403 1:5:10 ( 1 cement : 5 coarse sand ( zone iii ) : 10 graded stone aggregate 40 mm nominal size ) 404 providing and laying cement concrete in retaining walls, return walls, walls ( any thickness ) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : 405 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) . 406 making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 407 providing and laying damp proof course 40mm thick with cement concrete 1:2:4 ( 1 cement : 2 coarse sand ( zone iii ) : 4 graded stone aggregate 12.5mm nominal size ) 408 providing & applying a coat of residual petroleum bitumen of grade of vg 10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 409 reinforcedcementconcrete 410 centering and shuttering including strutting, propping etc. and removal of form for all heights: 411 foundations, footings, bases of columns, etc. for mass concrete 412 walls ( any thickness ) including attached pilasters, butteresses, plinth and string courses etc 413 columns, pillars, piers, abutments, posts and struts 414 small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like 415 edges of slabs and breaks in floors and walls 416 under 20 cms wide 417 suspended floors, roofs, landings, balconies and access platform. 418 lintels, beams, plinth beams, girders, bressumers and cantilevers. 419 providing precast cement concrete jali 1:2:4 ( 1 cement : 2 coarse sand ( zone iii ) : 4 graded stone aggregate 6mm nominal size ) , reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing with cement mortar 1:3 ( 1 cement: 3 fine sand ) etc. complete, excluding plastering of the jambs, sills and soffits. 420 50 mm thick 421 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 422 thermo mechanically treated bars of grade fe 500d or more. 423 add for plaster drip course / groove in plastered surface or moulding to r.c.c. projections. 424 providing and laying in position machine batched and machine mixed design mix m 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per is: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of engineer in charge.“ ( note : cement content considered in this item is @ 330 kg / cum.“excess / less cement used as per design mix is payable / recoverable separately ) . 425 all works upto plinth level 426 all works above plinth level upto floor v level 427 add for using extra cement in the items of design mix over and above the specified cement content therein. 428 brick work 429 brick work with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 in foundation and plinth in: 430 cement mortar 1:6 ( 1 cement : 6 coarse sand ) 431 providing and laying autoclaved aerated cement blocks masonry with 150mm / 230mm / 300 mm thick aac blocks in super structure above plinth level up to floor v level with rcc band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of engineer in charge. ( the payment of rcc band and reinforcement shall be made for seperately ) . 432 half brick masonry with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 in superstructure above plinth level up to floor v level. 433 cement mortar 1:4 ( 1 cement :4 coarse sand ) 434 extra for providing and placing in position 2 nos 6mm dia. m.s. bars at every third course of half brick masonry. 435 brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 including grouting with cement mortar 1:4 ( 1 cement : 4 fine sand ) . 436 marble work 437 providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand ) , joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 438 granite of any colour and shade 439 area of slab over 0.50 sqm 440 providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer in charge. 441 granite work 442 extra for fixing marble / granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. 443 extra for providing opening of required size & shape for wash basin / kitchen sink in kitchen platform, vanity counter and similar location in marble / granite / stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 444 wood work & pvc work 445 providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately ) . 446 second class teak wood 447 extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. ( area of opening for glass panes excluding portion inside rebate shall be measured ) . 448 providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 449 25 mm thick ( for cupboard ) including isi marked nickel plated bright finished m.s. piano hinges is : 3818 marked with necessary screws 450 providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) non decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 451 35 mm thick including isi marked stainless steel butt hinges with necessary screws 452 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters ( over all area of door shutter to be measured ) . 453 providing and fixing wire gauge shutters using galvanized m.s. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 454 35 mm thick shutters 455 kiln seasoned and chemically treated hollock wood 456 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coat with approved steel primer all complete. 457 fixed to steel windows by welding 458 providing and fixing fly proof galvanized m.s. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. 459 with 12 mm mild steel u beading 460 providing and fixing oxidised m.s. casement stays ( straight peg type ) with necessary screws etc. complete. 461 250 mm weighing not less than 150 gms 462 providing and fixing aluminium sliding door bolts, isi marked anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) , transparent or dyed to required colour or shade, with nuts and screws etc. complete : 463 250x16 mm 464 providing and fixing aluminium tower bolts, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 465 200x10 mm 466 providing and fixing aluminium handles, isi marked, anodised ( anodiccoating not less than grade ac 10 as per is : 1868 ) transparent or dyedto required colour or shade, with necessary screws etc. complete : 467 125 mm 468 providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. 469 twin rubber stopper 470 providing & fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to is : 2046 type s, including cost of adhesive of approved quality. 471 1.5 mm thick 472 providing and fixing pre laminated flat pressed 3 layer ( medium density ) particle board or graded wood particle board is : 3087 marked, with oneside decorative and other side balancing lamination grade i, type iiexterior grade is : 12823 marked, in shelves with screws and fittingswherever required, edges to be painted with polyurethane primer ( fittingsto be paid separately ) . 473 18 mm thick 474 providing and fixing factory made upvc white colour sliding glazed window upto 1.50 m in height dimension comprising of upvc multi chambered frame with in built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length ( shape & size according to upvc profile ) , appropriate dimension of upvc extruded glazing beads and upvc extruded interlocks, epdm gasket, wool pile, zinc alloy ( white powder coated ) touch locks with hook, zinc alloy body with single nylon rollers ( weight bearing capacity to be 40 kg ) , g.i fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of engineer in charge. ( single / double glass panes, wire mesh and silicon sealent shall be paid separately ) . variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 475 three track three panels sliding window with fly proof s.s wire mesh ( two nos. glazed & one no. wire mesh panels ) made of ( big series ) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. ( area of window above 1.75 sqm ) . 476 providing and fixing isi marked oxidised m.s. single acting spring hingeswith necessary screws etc. complete : 477 150 mm 478 providing and fixing oxidised m.s. hasp and staple ( safety type ) conforming to is : 363 with necessary screws etc. complete : 479 90 mm 480 providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 481 75 mm 482 providing and fixing wooden moulded corner beading of triangular shape to the junction of panelling etc. with iron screws, plugs and priming coat on unexposed surface etc. complete 2nd class teak wood. 483 50x50 mm ( base and height ) 484 float glass panes 485 4 mm thick glass pane ( weight not less than 10kg / sqm ) . 486 steel work 487 providing and fixing 1mm thick m.s. sheet door with frame of 40x40x6 mm angle iron and 3 mm m.s. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 488 using m.s. angles 40x40x6 mm for diagonal braces 489 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side / top / centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, ( sectional weight of only steel members shall be measured for payment ) . 490 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) 491 providing and fixing t iron frames for doors, windows and ventilators of mild steel tee sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 492 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) 493 providing and fixing circular / hexagonal cast iron or m.s. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick m.s. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron / m.s. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. clamp shall be made of 12 mm dia m.s. bar bent to shape as per standard drawing. 494 providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. 495 m.s. tube 496 providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 497 4.0 mm thick glass panes 498 flooring 499 providing and fixing glass strips in joints of terrazo / cement concrete floors. 500 40 mm wide and 4 mm thick 501 kota stone slab flooring over 20 mm ( average ) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 ( 1 cement : 4 coarse sand ) : 502 25 mm thick. 503 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm ( average ) thick cement mortar 1:3 ( 1 cement: 3 coarse sand ) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 504 extra for pre finished nosing in treads of steps of kota stone / sand stone slab. 505 extra for kota stone / sand stone in treads of steps and risers using single length up to 1.05 metre. 506 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 507 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3kg / sqm including pointing the joints with white cement and matching pigment etc., complete. 508 providing and laying vitrified floor tiles in different sizes ( thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3kg / sqm including grouting the joints with white cement and matching pigments etc., complete. 509 size of tile 600x600 mm 510 providing and laying vitrified tiles in different sizes ( thickness to be specified by manufacturer ) , with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 ( 1cement: 3 coarse sand ) , jointing with grey cement slurry @ 3.3kg / sqm including grouting the joint with white cement & matching pigments etc. complete. 511 size of tile 400x400 mm 512 roofing 513 providing and laying brick tiles over mumty roofs, grouted with cement mortar 1:3 ( 1 cement : 3 fine sand ) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 ( 1 cement : 3 fine sand ) and finished neat. 514 with common burnt clay f.p.s. ( non modular ) brick tilesof class designation 10 515 making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size ) over p.v.c. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 ( 1 cement : 3 coarse sand ) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 516 finishing 517 12 mm cement plaster of mix 518 1:6 ( 1 cement: 6 coarse sand ) 519 15 mm cement plaster on rough side of single or half brick wall of mix: 520 1:6 ( 1 cement: 6 coarse sand ) 521 cement plaster 1:3 ( 1 cement: 3 coarse sand ) finished with a floatingcoat of neat cement. 522 20 mm cement plaster 523 6mm cement plaster of mix 524 1:3 ( 1 cement : 3 fine sand ) 525 white washing with lime to give an even shade : 526 new work ( three or more coats ) 527 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 528 new work ( two or more coats ) over and including water thinnable priming coat with cement primer 529 finishing walls with premium acrylic smooth exterior paint withsilicone additives of required shade: 530 new work ( two or more coats applied @ 1.43 ltr / 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm ) 531 applying priming coat: 532 with ready mixed pink or grey primer of approved brand and manufacture on wood work ( hard and soft wood ) 533 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron / steel works 534 painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 535 two or more coats on new work 536 painting with black anti corrosive bitumastic paint of approved brand and manufacture to give an even shade : 537 two or more coats on new work 538 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 539 water proofing 540 providing and laying in situ seven course water proofing treatment with app ( atactic poly propylene ) modified polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 kg / sqm, which shall consist of blown type bitumen of grade 85 / 25 conforming to is : 702, 3rd and 5th layers of roofing membrane app modified polymeric membrane 1.5 mm thick of 2.25 kg / sqm weight consisting of five layers prefabricated with centre core as 20 micron hmhdpe film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron hmhdpe film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 ( 1cement : 3 fine sand ) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 ( 1 cement : 3 fine sand ) and finished neat ( item of laying brick tiles shall be paid for separately ) . 541 applying a slurry coat of neat cement using 2.75 kg / sqm of cement admixed with water proofing compound conforming to is. 2645 and approved by engineer in charge over the rcc slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. 542 laying brick bats with mortar using broken bricks / brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 ( 1 cement : 5 coarse sand ) admixed with water proofing compound conforming to is : 2645 and approved by engineerin charge over 20 mm thick layer of cement mortar of mix 1:5 ( 1 cement :5 coarse sand ) admixed with water proofing compound conforming to is : 2645 and approved by engineerin charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. 543 after two days of proper curing applying a second coat of cement slurry using 2.75 kg / sqm of cement admixed with water proofing compound conforming to is : 2645 and approved by engineer in charge. 544 finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 ( 1 cement :4 coarse sand ) admixed with water proofing compound conforming to is : 2645 and approved by engineer in charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. 545 the whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“all above operations to be done in order and as directed and specified by the engineer in charge : 546 providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of w.c., kitchen and the like consisting of: 547 ist course of applying cement slurry @ 4.4 kg / sqm mixed with water proofing compound conforming to is 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. 548 iind course of 20 mm cement plaster 1:3 ( 1 cement : 3 coarse sand ) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. 549 iiird course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. 550 ivth course of 400 micron thick pvc sheet. ( overlaps at joints of pvc sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg / sqm ) . 551 non shedule items 552 providing and laying cinder filling in sunken floors and other locationswith approved quality cinder including watering and light ramming etc.required for proper compaction / completion of the work complete in all respects as per drawings and as directed by the engineer in charge. 553 providing and fixing aluminium handles, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 554 150 mm 555 providing and fixing aluminium door buffer of approved make, design and colour with necessary screws etc all complete as directed and specified by the engineer in charge : 556 providing and laying 1st quality ceramic glazed anti skid floortiles of size 300x300 mm ( thickness to be specified by the manufacturer ) conforming to is:15622 in all colours, shades, sizes as approved over 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand ) including pointing the joints with white cement and matching pigment etc complete in all respects as per specifications / drawings and to the entire satisfaction to the architect. 557 staff quarter iii ( g+1 ) 558 earth work 559 earth work in excavation by mechanical means ( hydraulic excavator ) / manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 sqm on plan ) , including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 560 all kinds of soil. 561 excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 562 all kinds of soil 563 pipes, cables etc, not exceeding 80 mm dia. 564 pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 565 filling available excavated earth ( excluding rock ) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 566 roofing 567 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, ( i ) single socketed pipes. 568 110 mm diameter 569 providing and fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 570 coupler 571 110 mm 572 bend 87.5° 573 110 mm bend 574 shoe ( plain ) 575 110 mm shoe 576 providing and fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with m.s. screws of required length, including cutting brick work and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand ) and making good the wall etc. complete. 577 110 mm 578 providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 579 sanitary installations 580 providing and fixing water closet squatting pan ( indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 581 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 582 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. 583 w.c. pan with isi marked white solid plastic seat and lid 584 providing and fixing wash basin with c.i. brackets, 15 mm c.p. brass pillar taps, 32 mm c.p. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 585 white vitreous china flat back wash basin size 550x 400 mm with single 15 mm c.p. brass pillar tap 586 providing and fixing stainless steel a isi 304 ( 18 / 8 ) kitchen sink as per is: 13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 587 kitchen sink with drain board 588 510x1040 mm bowl depth 250 mm 589 extra for using coloured pedestal type w.c pan ( european type ) with low level cistern of same colour instead of white vitreous china w.c pan and cistern. 590 providing and fixing 600x450 mm beveled edge mirror of superior glass ( of approved quality ) complete with 6 mm thick hard board ground fixed to wooden cleats with c.p. brass screws and washers complete. 591 providing and fixing toilet paper holder : 592 vitreous china 593 providing and fixing soil, waste and vent pipes : 594 100 mm dia. 595 centrifugally cast ( spun ) iron socket & spigot ( s&s ) pipe as per is: 3989 596 75mm diameter 597 centrifugally cast ( spun ) iron socketed pipe as per is: 3989 598 providing and fixing m.s. holder bat clamps of approved design to sand cast iron / cast iron ( spun ) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) , including cost of cutting holes and making good the walls etc. : 599 for 100 mm dia. pipe 600 for 75 mm dia. pipe 601 providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 602 100 mm 603 sand cast iron s&s as per is 3989 604 75 mm 605 sand cast iron s&s as per is 3989 606 providing and fixing plain bend of required degree. 607 100 mm 608 sand cast iron s&s as per is : 3989 609 75 mm 610 sand cast iron s&s as per is 3989 611 providing and fixing heel rest sanitary bend 612 100 mmdia 613 sand cast iron s&s as per is 3989 614 75 mm dia 615 sand cast iron s&s as per is 3989 616 providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 617 100x100x100mm 618 sand cast iron s&s as per is 3989 619 75x75x75mm 620 sand cast iron s&s as per is 3989 621 providing and fixing single equal plain junction of required degree 622 100x100x100mm 623 sand cast iron s&s as per is 3989 624 75x75x75mm 625 sand cast iron s&s as per is 3989 626 providing and fixing door piece, insertion rubber washer 3mm thick, bolts & nuts complete : 627 100 mm 628 sand cast iron s&s as per is 3989 629 75 mm 630 sand cast iron s&s as per is 3989 631 providing and fixing terminal guard : 632 100 mm 633 sand cast iron s&s as per is 3989 634 75 mm 635 sand cast iron s&s as per is 3989 636 providing and fixing collar : 637 100 mm 638 sand cast iron s&s as per is 3989 639 75 mm 640 sand cast iron s&s as per is 3989 641 providing lead caulked joints to sand cast iron / centrifugally cast ( spun ) iron pipes and fittings of diameter : 642 100 mm 643 75 mm 644 providing and fixing m.s. stays and clamps for sand cast iron / centrifugally cast ( spun ) iron pipes of diameter : 645 100 mm 646 75 mm 647 providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 648 100 mm inlet and 100 mm outlet 649 sand cast iron s&s as per is: 1729 650 cutting chases in brick masonry walls for following diameter sand cast iron / centrifugally cast ( spun ) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size ) , including necessary plaster and pointing in cement mortar 1:4 ( 1 cement : 4 coarse sand ) : 651 100 mm dia 652 painting sand cast iron / centrifugally cast ( spun ) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer ( of approved quality ) for new work : 653 100 mm diameter pipe 654 75 mm diameter pipe 655 providing and fixing ptmt waste coupling for wash basin and sink, of approved quality and colour. 656 waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms 657 providing and fixing ptmt bottle trap for wash basin and sink. 658 bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms 659 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 660 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour. 661 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 662 providing and fixing g.i. pipes complete with g.i. fittings including trenching & refilling. 663 external work 664 32mmdia nominal bore 665 40mmdia nominal bore 666 50mmdia nominal bore 667 water supply 668 providing and fixing chlorinated polyvinyl chloride ( cpvc ) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 669 internal work exposed on wall 670 25 mm nominal outer dia pipes metre 671 32 mm nominal outer dia pipes metre 672 providing and fixing chlorinated polyvinyl chloride ( cpvc ) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i / c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 673 concealed work, including cutting chases and making good the walls etc. 674 15 mm nominal outer dia pipes 675 20 mm nominal outer dia pipes 676 making connection of g.i. distribution branch with g.i. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 677 25 to 40 mm nominal bore 678 providing and fixing brass stop cock of approved quality : 679 15 mm nominal bore 680 20 mm nominal bore 681 providing and fixing gun metal gate valve with c.i. wheel of approved quality ( screwed end ) : 682 25mm nominal bore 683 32mm nominal bore 684 40mm nominal bore 685 providing and fixing ball valve ( brass ) of approved quality, high or low pressure, with plastic floats complete : 686 25 mm nominal bore 687 providing and fixing brass ferrule with c.i. mouth cover including boring and tapping the main : 688 25 mm nominal bore 689 providing and fixing uplasticised pvc connection pipe with brass unions : 690 45 cm length 691 15 mm nominal bore 692 providing and fixing c.p. brass shower rose with 15 or 20 mm inlet : 693 100 mm diameter 694 providing and placing on terrace ( at all floor levels ) polyethylene water storage tank, is : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 695 rectangular tank 696 providing and fixing c.p. brass bib cock of approved quality conforming to is:8931 : 697 15 mm nominal bore 698 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 699 15 mm nominal bore 700 providing and fixing c.p. brass stop cock ( concealed ) of standard design and of approved make conforming to is:8931. 701 15 mm nominal bore. 702 providing and fixing c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 703 15 mm nominal bore 704 providing and fixing ptmt grating of approved quality and colour. 705 circular type. 706 100 mm nominal dia. 707 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) , including finishing complete so as to make it leak proof. 708 sewarage & drainage 709 providing, laying and jointing glazed stoneware pipes class sp 1 with stiff mixture of cement mortar in the proportion of 1:1 ( 1 cement : 1 fine sand ) including testing of joints etc. complete : 710 100 mm diameter 711 150 mm diameter 712 providing and laying cement concrete 1:5:10 ( 1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size ) all round s.w. pipes including bed concrete as per standard design : 713 100 mm diameter s.w. pipe 714 150 mm diameter s.w. pipe 715 providing and fixing square mouth s.w. gully trap class sp 1 complete with c.i. grating brick masonry chamber with water tight c.i. cover with frame of 300 x300 mm size ( inside ) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70kg as per standard design: 716 150 x 100 mm size p type 717 with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 718 constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with r.c.c. top slab with 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) , foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size ) , inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand ) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design : 719 inside size 90x80 cm and 45 cm deep including c.i. cover with frame ( light duty ) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg ( weight of cover 23 kg and weight of frame 15 kg ) : 720 with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 721 extra for depth for manholes : 722 size 90x80 cm 723 with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 724 providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per is : 10910, on 12 mm dia steel bar conforming to is: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) complete as per design. 725 making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) cement plastered on both sides with cement mortar 1:3 ( 1 cement : 3 coarse sand ) , finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 726 for pipes 100 to 250 mm diameter 727 providing, laying and jointing non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete : 728 150 mm dia rcc pipe 729 250 mm dia rcc pipe 730 non shedule items 731 providing and fixing floor drain points of 75 x 50mmreducer bend with 100 mm dia cp grating with frame, embedded in floor including making joints with waste pipe etc. complete in all respects as per drawing and as directed by theengineer in charge. 732 providing & fixing sink mixer with swinging casted spout ( wall mounted jaquar model con 309 kn ) / approved equal with 450mm long copper pipes & brass nuts. 733 providing and fixing concealed single leverbath & overhead shower mixer of hindware make and model no. ( f360019cp ) respectively or equivalent approved make as approved byengineer in charge. 734 supplying, fixing, testing and commissioning of storage type water heater ( geyser ) etc. with stainless steel body , copper container , automatic thermostatic control electric element, pressure release valve, m.s. nuts and bolts etc. conforming to is: 2082 735 25 litre capacity 736 sq type iii ( g+1 ) 737 subhead i wiring 738 wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. 739 group c 740 wiring for light / power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 741 supplying and fixing following size / modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 742 4 module ( 125 mmx75 mm ) 743 supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 744 15 / 16 a switch 745 3 pin 5 / 6 a socket outlet 746 telephone socket outlet 747 tv antenna socket outlet 748 wiring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed steel conduit as required. 749 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire 750 2 x 10 sq. mm + 1 x 6 sq. mm earth wire 751 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface / recessed steel / pvc conduit as required. 752 supplying and fixing of following sizes of steel conduit along with accessories in surface / recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 753 25 mm 754 supplying and fixing following size / modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 755 1 or 2 module ( 75 mmx75 mm ) 756 supplying and drawing following pair 0.5 mm dia frls pvc insulated annealed copper conductor, unarmored telephone cable in the existing surface / recessed steel / pvc conduit as required. 757 2 pair 758 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. 759 20 mm 760 25 mm 761 providing and fixing in position 2mm thick m.s. telephone junction box of size suitable for fixing of following krone tag block with key lock arrangement. also provide clamps for fixing tag blocks. 762 10 pair telephone tag blockwith box 763 supplying, laying of 10 pair unarmoured pvc insulated copper conductor ( atc ) telephone cable in ground / existing pipes / on wall and making connection with telephone main junction box ( mdf ) including supports and all accessories as required 764 10 pair cable unarmoured 765 subhead ii supply & installation of fittings 766 supplying of following box type fl. fitting made out of crca sheet finished in antirust treated non yellowing super white stove enamelled paint duly wired with copper wound heavy duty choke starter holder, starter but without lamp complete etc. as reqd. 767 mounting rail for tled lamps 1600 lumens ( tmc 501 p 1xt led with essential led 18w tube ) 768 supplying of wall bracket light fittings suitable for 11 / 13 w cfl lamp. the fitting shall be made up of m.s. powder coated provided with integral ballast, frosted glass and 1 no. 11 / 13 wlamp duly wired upto the connector block complete as required. ( decon cat. no.05aam ) 769 supplying of ceiling light fittings suitable for 1 x 15 / 20 w led lamp. the fitting shall be made up of m.s. powder coated provided with electronic ballast, 1 no. 15 / 20 w led lamp duly wired upto the connector block etc. complete as required. 770 cirrus mini pro 15 / 20 watt & 1100 / 1600 lumens ( philips sm200c led11s 6500 psu od wh ) 771 supplying of bulk head fittings suitable for 10 w led lamp complete with ballast & accessories such as glass, wire guard, 60 w cfl lamp etc. complete as required. 772 endural led bulkhead, 10 w, 600 lumen such as ( philips wt202w led6s cw psu s2 pc ) 773 supplying of exhaustfan, all complete with mounting ring frame i / c bracket, but without regulator with shutters in the following sizes. ( g.e. alsthom, khaitan & havells company ) 774 300 mm 4 pole 775 supplying of 1400 mm sweep a.c. electric ceiling fans, capacitor type with double ball bearing complete with 300 mm down rod, canopies, shackles, blades, but without regulator suitable for operation on 230 / 240 volts, 50 hz, single phase, a.c. supply. ( crompton, khaitan & havells company ) 776 supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 777 installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 778 installation, testing and commissioning of pre wired, light fixture / compact fluorescent fitting of all types, complete with all accessories and tube / lamp etc. directly on ceiling / wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 779 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 780 upto 450 mm sweep 781 extra for fixing the louvers / shutters complete with frame for a exhaust fan of all sizes. 782 installation, testing and commissioning of wall bracket / ceiling fittings of all sizes and shapes containing upto two gls / cfl / led lamps per fitting, complete with all accessories including connections etc. as required. 783 supplying and fixing call bell / buzzer suitable for single phase, 230 v, complete as required. 784 subhead iii distribution board 785 supplying, installing, testing and commissioning of compartmentalised cubical type meter board for installation of single phase meter. the cubical board shall be made of 2mm thick c.r.c.a sheet, duly phosphatised powder coated complete with connection bus bar and following accessories mounted in it. 786 meter board 787 incoming : 788 40a tp mccb having breaking capacity 25 ka 1 no. 789 outgoing : 790 space for single phase energy meter 4 nos. 791 25 amp dp mcb 4 nos. 792 supplying, installing, testing & commissioning of single phase electronic energy meter, tested as per electricity boards requirement. 793 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 794 12 way, spn 795 supplying and fixing following rating, double pole, 240 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 796 40 amps 797 supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. asrequired. 798 25 amps 799 supplying of xlpe insulated, pvc sheathed 1.1 kv grade aluminium conductor heavy duty armoured cable as per is : 7098 of size : 800 4 x 16 sq.mm. 801 providing, laying and fixing following dia rcc pipe np2 class ( light duty ) in ground complete with rcc collars, jointing with cement mortar 1:2 ( 1 cement : 2 fine sand ) including trenching ( 75 cm deep ) and refilling etc. as required for crossing road / walls 802 100 mm dia 803 supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 804 single pole 805 subhead iv earthing 806 earthing with g.i. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. 807 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re filling as required. 808 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 809 subhead v lightning conductor 810 providing and fixing of lightning conductor finial, made of 25mm dia 300 mm long, g.i. tube, having single prong at top, with85 mm dia 6 mm thick g.i. base plate including holes etc.complete as required. 811 jointing copper / g.i. tape ( with another copper / g i tape, base of the finial or any other metallic object ) by riveting / nut bolting / sweating and soldering etc as required. 812 fixing of copper / g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( for horizontal run ) 813 fixing of copper / g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( for vertical run ) 814 providing and fixing testing joint, made of 20 mm x 3 mm thickg.i. strip, 125 mm long, with 4 nos. of g.i. bolts, nuts, chucknuts and spring washers etc. complete as required. 815 laying copper / g.i. tape 32 mm x 6 mm from earth electrodedirectly in ground as required 816 staff quarters type ii 817 earth work 818 earth work in excavation by mechanical means ( hydraulic excavator ) / manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 sqm on plan ) , including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 819 all kinds of soil 820 filling available excavated earth ( excluding rock ) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 821 supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 822 supplying chemical emulsion in sealed containers including delivery as specified. 823 chlorpyriphos / lindane emulsifiable concentrate of 20% 824 diluting and injecting chemical emulsion for post constructional anti termite treatment ( excluding the cost of chemical emulsion ) : 825 treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 ( 1 cement : 2 coarse sand ) to match the existing floor: 826 with chlorpyriphos / lindane e.c. 20% with 1% concentration 827 excavating, supplying and filling of local earth ( including royalty ) by mechanical transport upto a lead of 5km also includingramming and watering of the earth in layers not exceeding 20cm in trenches, plinth, sides of foundation etc. complete. 828 concrete work 829 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 830 1:5:10 ( 1 cement : 5 coarse sand ( zone iii ) : 10 graded stone aggregate 40 mm nominal size ) 831 providing and laying cement concrete in retaining walls, return walls, walls ( any thickness ) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : 832 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) . 833 providing and laying damp proof course 40mm thick with cement concrete 1:2:4 ( 1 cement : 2 coarse sand ( zone iii ) : 4 graded stone aggregate 12.5mm nominal size ) 834 providing & applying a coat of residual petroleum bitumen of grade of vg 10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 835 making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 836 reinforcedcementconcrete 837 centering and shuttering including strutting, propping etc. and removal of form for all heights: 838 foundations, footings, bases of columns, etc. for mass concrete 839 walls ( any thickness ) including attached pilasters, butteresses, plinth and string courses etc 840 columns, pillars, piers, abutments, posts and struts 841 small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like 842 edges of slabs and breaks in floors and walls 843 under 20 cms wide 844 suspended floors, roofs, landings, balconies and access platform. 845 lintels, beams, plinth beams, girders, bressumers and cantilevers. 846 providing precast cement concrete jali 1:2:4 ( 1 cement : 2 coarse sand ( zone iii ) : 4 graded stone aggregate 6mm nominal size ) , reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing with cement mortar 1:3 ( 1 cement: 3 fine sand ) etc. complete, excluding plastering of the jambs, sills and soffits. 847 50 mm thick 848 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 849 thermo mechanically treated bars of grade fe 500d or more. 850 add for plaster drip course / groove in plastered surface or moulding to r.c.c. projections. 851 providing and laying in position machine batched and machine mixed design mix m 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per is: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of engineer in charge.“ ( note : cement content considered in this item is @ 330 kg / cum.“excess / less cement used as per design mix is payable / recoverable separately ) . 852 all works upto plinth level 853 all works above plinth level upto floor v level 854 add for using extra cement in the items of design mix over and above the specified cement content therein. 855 brick work 856 brick work with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 in foundation and plinth in: 857 cement mortar 1:6 ( 1 cement : 6 coarse sand ) 858 providing and laying autoclaved aerated cement blocks masonry with 150mm / 230mm / 300 mm thick aac blocks in super structure above plinth level up to floor v level with rcc band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of engineer in charge. ( the payment of rcc band and reinforcement shall be made for seperately ) . 859 half brick masonry with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 in superstructure above plinth level up to floor v level. 860 cement mortar 1:4 ( 1 cement :4 coarse sand ) 861 extra for providing and placing in position 2 nos 6mm dia. m.s. bars at every third course of half brick masonry. 862 brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 including grouting with cement mortar 1:4 ( 1 cement : 4 fine sand ) . 863 marble work 864 providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand ) , joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 865 granite of any colour and shade 866 area of slab over 0.50 sqm 867 providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer in charge. 868 granite work 869 extra for fixing marble / granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. 870 extra for providing opening of required size & shape for wash basin / kitchen sink in kitchen platform, vanity counter and similar location in marble / granite / stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 871 wood work & pvc work 872 providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately ) . 873 second class teak wood 874 extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. ( area of opening for glass panes excluding portion inside rebate shall be measured ) . 875 providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 876 25 mm thick ( for cupboard ) including isi marked nickel plated bright finished m.s. piano hinges is : 3818 marked with necessary screws 877 providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) non decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 878 35 mm thick including isi marked stainless steel butt hinges with necessary screws 879 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters ( over all area of door shutter to be measured ) . 880 providing and fixing wire gauge shutters using galvanized m.s. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 881 35 mm thick shutters 882 kiln seasoned and chemically treated hollock wood 883 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coat with approved steel primer all complete. 884 fixed to steel windows by welding 885 providing and fixing fly proof galvanized m.s. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. 886 with 12 mm mild steel u beading 887 providing and fixing oxidised m.s. casement stays ( straight peg type ) with necessary screws etc. complete. 888 250 mm weighing not less than 150 gms 889 providing and fixing aluminium sliding door bolts, isi marked anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) , transparent or dyed to required colour or shade, with nuts and screws etc. complete : 890 250x16 mm 891 providing and fixing aluminium tower bolts, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 892 200x10 mm 893 providing and fixing aluminium handles, isi marked, anodised ( anodiccoating not less than grade ac 10 as per is : 1868 ) transparent or dyedto required colour or shade, with necessary screws etc. complete : 894 125 mm 895 providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. 896 twin rubber stopper 897 providing & fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to is : 2046 type s, including cost of adhesive of approved quality. 898 1.5 mm thick 899 providing and fixing pre laminated flat pressed 3 layer ( medium density ) particle board or graded wood particle board is : 3087 marked, with oneside decorative and other side balancing lamination grade i, type iiexterior grade is : 12823 marked, in shelves with screws and fittingswherever required, edges to be painted with polyurethane primer ( fittingsto be paid separately ) . 900 18 mm thick 901 providing and fixing factory made upvc white colour sliding glazed window upto 1.50 m in height dimension comprising of upvc multi chambered frame with in built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length ( shape & size according to upvc profile ) , appropriate dimension of upvc extruded glazing beads and upvc extruded interlocks, epdm gasket, wool pile, zinc alloy ( white powder coated ) touch locks with hook, zinc alloy body with single nylon rollers ( weight bearing capacity to be 40 kg ) , g.i fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of engineer in charge. ( single / double glass panes, wire mesh and silicon sealent shall be paid separately ) . variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 902 three track three panels sliding window with fly proof s.s wire mesh ( two nos. glazed & one no. wire mesh panels ) made of ( big series ) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. ( area of window above 1.75 sqm ) . 903 providing and fixing isi marked oxidised m.s. single acting spring hingeswith necessary screws etc. complete : 904 150 mm 905 providing and fixing oxidised m.s. hasp and staple ( safety type ) conforming to is : 363 with necessary screws etc. complete : 906 90 mm 907 providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 908 75 mm 909 providing and fixing wooden moulded corner beading of triangular shape to the junction of panelling etc. with iron screws, plugs and priming coat on unexposed surface etc. complete 2nd class teak wood. 910 50x50 mm ( base and height ) 911 float glass panes 912 4 mm thick glass pane ( weight not less than 10kg / sqm ) . 913 steel work 914 providing and fixing 1mm thick m.s. sheet door with frame of 40x40x6 mm angle iron and 3 mm m.s. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 915 using m.s. angles 40x40x6 mm for diagonal braces 916 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side / top / centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, ( sectional weight of only steel members shall be measured for payment ) . 917 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) 918 providing and fixing t iron frames for doors, windows and ventilators of mild steel tee sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 919 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) 920 providing and fixing circular / hexagonal cast iron or m.s. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick m.s. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron / m.s. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. clamp shall be made of 12 mm dia m.s. bar bent to shape as per standard drawing. 921 providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. 922 m.s. tube 923 providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 924 4.0 mm thick glass panes 925 flooring 926 providing and fixing glass strips in joints of terrazo / cement concrete floors. 927 40 mm wide and 4 mm thick 928 kota stone slab flooring over 20 mm ( average ) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 ( 1 cement : 4 coarse sand ) : 929 25 mm thick. 930 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm ( average ) thick cement mortar 1:3 ( 1 cement: 3 coarse sand ) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 931 extra for pre finished nosing in treads of steps of kota stone / sand stone slab. 932 extra for kota stone / sand stone in treads of steps and risers using single length up to 1.05 metre. 933 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 934 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3kg / sqm including pointing the joints with white cement and matching pigment etc., complete. 935 providing and laying vitrified floor tiles in different sizes ( thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3kg / sqm including grouting the joints with white cement and matching pigments etc., complete. 936 size of tile 600x600 mm 937 providing and laying vitrified tiles in different sizes ( thickness to be specified by manufacturer ) , with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 ( 1cement: 3 coarse sand ) , jointing with grey cement slurry @ 3.3kg / sqm including grouting the joint with white cement & matching pigments etc. complete. 938 size of tile 400x400 mm 939 roofing 940 providing and laying brick tiles over mumty roofs, grouted with cement mortar 1:3 ( 1 cement : 3 fine sand ) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 ( 1 cement : 3 fine sand ) and finished neat. 941 with common burnt clay f.p.s. ( non modular ) brick tilesof class designation 10 942 making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size ) over p.v.c. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 ( 1 cement : 3 coarse sand ) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 943 finishing 944 12 mm cement plaster of mix 945 1:6 ( 1 cement: 6 coarse sand ) 946 15 mm cement plaster on rough side of single or half brick wall of mix: 947 1:6 ( 1 cement: 6 coarse sand ) 948 cement plaster 1:3 ( 1 cement: 3 coarse sand ) finished with a floatingcoat of neat cement. 949 20 mm cement plaster 950 6mm cement plaster of mix 951 1:3 ( 1 cement : 3 fine sand ) 952 white washing with lime to give an even shade : 953 new work ( three or more coats ) 954 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 955 new work ( two or more coats ) over and including water thinnable priming coat with cement primer 956 finishing walls with premium acrylic smooth exterior paint withsilicone additives of required shade: 957 new work ( two or more coats applied @ 1.43 ltr / 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm ) 958 applying priming coat: 959 with ready mixed pink or grey primer of approved brand and manufacture on wood work ( hard and soft wood ) 960 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron / steel works 961 painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 962 two or more coats on new work 963 painting with black anti corrosive bitumastic paint of approved brand and manufacture to give an even shade : 964 two or more coats on new work 965 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 966 water proofing 967 providing and laying in situ seven course water proofing treatment with app ( atactic poly propylene ) modified polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 kg / sqm, which shall consist of blown type bitumen of grade 85 / 25 conforming to is : 702, 3rd and 5th layers of roofing membrane app modified polymeric membrane 1.5 mm thick of 2.25 kg / sqm weight consisting of five layers prefabricated with centre core as 20 micron hmhdpe film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron hmhdpe film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 ( 1cement : 3 fine sand ) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 ( 1 cement : 3 fine sand ) and finished neat ( item of laying brick tiles shall be paid for separately ) . 968 applying a slurry coat of neat cement using 2.75 kg / sqm of cement admixed with water proofing compound conforming to is. 2645 and approved by engineer in charge over the rcc slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. 969 laying brick bats with mortar using broken bricks / brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 ( 1 cement : 5 coarse sand ) admixed with water proofing compound conforming to is : 2645 and approved by engineerin charge over 20 mm thick layer of cement mortar of mix 1:5 ( 1 cement :5 coarse sand ) admixed with water proofing compound conforming to is : 2645 and approved by engineerin charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. 970 after two days of proper curing applying a second coat of cement slurry using 2.75 kg / sqm of cement admixed with water proofing compound conforming to is : 2645 and approved by engineer in charge. 971 finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 ( 1 cement :4 coarse sand ) admixed with water proofing compound conforming to is : 2645 and approved by engineer in charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. 972 the whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“all above operations to be done in order and as directed and specified by the engineer in charge : 973 providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of w.c., kitchen and the like consisting of: 974 ist course of applying cement slurry @ 4.4 kg / sqm mixed with water proofing compound conforming to is 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. 975 iind course of 20 mm cement plaster 1:3 ( 1 cement : 3 coarse sand ) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. 976 iiird course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. 977 ivth course of 400 micron thick pvc sheet. ( overlaps at joints of pvc sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg / sqm ) . 978 non shedule items 979 providing and laying cinder filling in sunken floors and other locationswith approved quality cinder including watering and light ramming etc.required for proper compaction / completion of the work complete in all respects as per drawings and as directed by the engineer in charge. 980 providing and fixing aluminium handles, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 981 150 mm 982 providing and fixing aluminium door buffer of approved make, design and colour with necessary screws etc all complete as directed and specified by the engineer in charge : 983 providing and laying 1st quality ceramic glazed anti skid floortiles of size 300x300 mm ( thickness to be specified by the manufacturer ) conforming to is:15622 in all colours, shades, sizes as approved over 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand ) including pointing the joints with white cement and matching pigment etc complete in all respects as per specifications / drawings and to the entire satisfaction to the architect. 984 staff quarter ii ( g+1 ) 985 earth work 986 earth work in excavation by mechanical means ( hydraulic excavator ) / manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 sqm on plan ) , including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 987 all kinds of soil. 988 excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 989 all kinds of soil 990 pipes, cables etc, not exceeding 80 mm dia. 991 pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 992 filling available excavated earth ( excluding rock ) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 993 roofing 994 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, ( i ) single socketed pipes. 995 110 mm diameter 996 providing and fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 997 coupler 998 110 mm 999 bend 87.5° 1000 110 mm bend 1001 shoe ( plain ) 1002 110 mm shoe 1003 providing and fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with m.s. screws of required length, including cutting brick work and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand ) and making good the wall etc. complete. 1004 110 mm 1005 providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 1006 sanitary installations 1007 providing and fixing water closet squatting pan ( indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1008 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 1009 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. 1010 w.c. pan with isi marked white solid plastic seat and lid 1011 providing and fixing wash basin with c.i. brackets, 15 mm c.p. brass pillar taps, 32 mm c.p. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 1012 white vitreous china flat back wash basin size 550x 400 mm with single 15 mm c.p. brass pillar tap 1013 providing and fixing stainless steel a isi 304 ( 18 / 8 ) kitchen sink as per is: 13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 1014 kitchen sink with drain board 1015 510x1040 mm bowl depth 250 mm 1016 extra for using coloured pedestal type w.c pan ( european type ) with low level cistern of same colour instead of white vitreous china w.c pan and cistern. 1017 providing and fixing 600x450 mm beveled edge mirror of superior glass ( of approved quality ) complete with 6 mm thick hard board ground fixed to wooden cleats with c.p. brass screws and washers complete. 1018 providing and fixing toilet paper holder : 1019 vitreous china 1020 providing and fixing soil, waste and vent pipes : 1021 100 mm dia. 1022 centrifugally cast ( spun ) iron socket & spigot ( s&s ) pipe as per is: 3989 1023 75mm diameter 1024 centrifugally cast ( spun ) iron socketed pipe as per is: 3989 1025 providing and fixing m.s. holder bat clamps of approved design to sand cast iron / cast iron ( spun ) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) , including cost of cutting holes and making good the walls etc. : 1026 for 100 mm dia. pipe 1027 for 75 mm dia. pipe 1028 providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 1029 100 mm 1030 sand cast iron s&s as per is 3989 1031 75 mm 1032 sand cast iron s&s as per is 3989 1033 providing and fixing plain bend of required degree. 1034 100 mm 1035 sand cast iron s&s as per is : 3989 1036 75 mm 1037 sand cast iron s&s as per is 3989 1038 providing and fixing heel rest sanitary bend 1039 100 mmdia 1040 sand cast iron s&s as per is 3989 1041 75 mm dia 1042 sand cast iron s&s as per is 3989 1043 providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 1044 100x100x100mm 1045 sand cast iron s&s as per is 3989 1046 75x75x75mm 1047 sand cast iron s&s as per is 3989 1048 providing and fixing single equal plain junction of required degree 1049 100x100x100mm 1050 sand cast iron s&s as per is 3989 1051 75x75x75mm 1052 sand cast iron s&s as per is 3989 1053 providing and fixing door piece, insertion rubber washer 3mm thick, bolts & nuts complete : 1054 100 mm 1055 sand cast iron s&s as per is 3989 1056 75 mm 1057 sand cast iron s&s as per is 3989 1058 providing and fixing terminal guard : 1059 100 mm 1060 sand cast iron s&s as per is 3989 1061 75 mm 1062 sand cast iron s&s as per is 3989 1063 providing and fixing collar : 1064 100 mm 1065 sand cast iron s&s as per is 3989 1066 75 mm 1067 sand cast iron s&s as per is 3989 1068 providing lead caulked joints to sand cast iron / centrifugally cast ( spun ) iron pipes and fittings of diameter : 1069 100 mm 1070 75 mm 1071 providing and fixing m.s. stays and clamps for sand cast iron / centrifugally cast ( spun ) iron pipes of diameter : 1072 100 mm 1073 75 mm 1074 providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 1075 100 mm inlet and 100 mm outlet 1076 sand cast iron s&s as per is: 1729 1077 cutting chases in brick masonry walls for following diameter sand cast iron / centrifugally cast ( spun ) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size ) , including necessary plaster and pointing in cement mortar 1:4 ( 1 cement : 4 coarse sand ) : 1078 100 mm dia 1079 painting sand cast iron / centrifugally cast ( spun ) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer ( of approved quality ) for new work : 1080 100 mm diameter pipe 1081 75 mm diameter pipe 1082 providing and fixing ptmt waste coupling for wash basin and sink, of approved quality and colour. 1083 waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms 1084 providing and fixing ptmt bottle trap for wash basin and sink. 1085 bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms 1086 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 1087 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour. 1088 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 1089 providing and fixing g.i. pipes complete with g.i. fittings including trenching & refilling. 1090 external work 1091 32mmdia nominal bore 1092 40mmdia nominal bore 1093 50mmdia nominal bore 1094 water supply 1095 providing and fixing chlorinated polyvinyl chloride ( cpvc ) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 1096 internal work exposed on wall 1097 25 mm nominal outer dia pipes metre 1098 32 mm nominal outer dia pipes metre 1099 providing and fixing chlorinated polyvinyl chloride ( cpvc ) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i / c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 1100 concealed work, including cutting chases and making good the walls etc. 1101 15 mm nominal outer dia pipes 1102 20 mm nominal outer dia pipes 1103 making connection of g.i. distribution branch with g.i. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 1104 25 to 40 mm nominal bore 1105 providing and fixing brass stop cock of approved quality : 1106 15 mm nominal bore 1107 20 mm nominal bore 1108 providing and fixing gun metal gate valve with c.i. wheel of approved quality ( screwed end ) : 1109 25mm nominal bore 1110 32mm nominal bore 1111 40mm nominal bore 1112 providing and fixing ball valve ( brass ) of approved quality, high or low pressure, with plastic floats complete : 1113 25 mm nominal bore 1114 providing and fixing brass ferrule with c.i. mouth cover including boring and tapping the main : 1115 25 mm nominal bore 1116 providing and fixing uplasticised pvc connection pipe with brass unions : 1117 45 cm length 1118 15 mm nominal bore 1119 providing and fixing c.p. brass shower rose with 15 or 20 mm inlet : 1120 100 mm diameter 1121 providing and placing on terrace ( at all floor levels ) polyethylene water storage tank, is : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 1122 rectangular tank 1123 providing and fixing c.p. brass bib cock of approved quality conforming to is:8931 : 1124 15 mm nominal bore 1125 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 1126 15 mm nominal bore 1127 providing and fixing c.p. brass stop cock ( concealed ) of standard design and of approved make conforming to is:8931. 1128 15 mm nominal bore. 1129 providing and fixing c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 1130 15 mm nominal bore 1131 providing and fixing ptmt grating of approved quality and colour. 1132 circular type. 1133 100 mm nominal dia. 1134 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) , including finishing complete so as to make it leak proof. 1135 sewarage & drainage 1136 providing, laying and jointing glazed stoneware pipes class sp 1 with stiff mixture of cement mortar in the proportion of 1:1 ( 1 cement : 1 fine sand ) including testing of joints etc. complete : 1137 100 mm diameter 1138 150 mm diameter 1139 providing and laying cement concrete 1:5:10 ( 1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size ) all round s.w. pipes including bed concrete as per standard design : 1140 100 mm diameter s.w. pipe 1141 150 mm diameter s.w. pipe 1142 providing and fixing square mouth s.w. gully trap class sp 1 complete with c.i. grating brick masonry chamber with water tight c.i. cover with frame of 300 x300 mm size ( inside ) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70kg as per standard design: 1143 150 x 100 mm size p type 1144 with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 1145 constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with r.c.c. top slab with 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) , foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size ) , inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand ) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design : 1146 inside size 90x80 cm and 45 cm deep including c.i. cover with frame ( light duty ) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg ( weight of cover 23 kg and weight of frame 15 kg ) : 1147 with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 1148 extra for depth for manholes : 1149 size 90x80 cm 1150 with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 1151 providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per is : 10910, on 12 mm dia steel bar conforming to is: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) complete as per design. 1152 making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) cement plastered on both sides with cement mortar 1:3 ( 1 cement : 3 coarse sand ) , finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 1153 for pipes 100 to 250 mm diameter 1154 providing, laying and jointing non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete : 1155 150 mm dia rcc pipe 1156 250 mm dia rcc pipe 1157 sq type ii ( g+1 ) 1158 subhead i wiring 1159 wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. 1160 group c 1161 wiring for light / power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 1162 supplying and fixing following size / modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 1163 4 module ( 125 mmx75 mm ) 1164 supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1165 15 / 16 a switch 1166 3 pin 5 / 6 a socket outlet 1167 telephone socket outlet 1168 tv antenna socket outlet 1169 wiring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed steel conduit as required. 1170 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire 1171 2 x 10 sq. mm + 1 x 6 sq. mm earth wire 1172 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface / recessed steel / pvc conduit as required. 1173 supplying and fixing of following sizes of steel conduit along with accessories in surface / recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 1174 25 mm 1175 supplying and fixing following size / modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 1176 1 or 2 module ( 75 mmx75 mm ) 1177 supplying and drawing following pair 0.5 mm dia frls pvc insulated annealed copper conductor, unarmored telephone cable in the existing surface / recessed steel / pvc conduit as required. 1178 2 pair 1179 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. 1180 20 mm 1181 25 mm 1182 providing and fixing in position 2mm thick m.s. telephone junction box of size suitable for fixing of following krone tag block with key lock arrangement. also provide clamps for fixing tag blocks. 1183 10 pair telephone tag blockwith box 1184 supplying, laying of 10 pair unarmoured pvc insulated copper conductor ( atc ) telephone cable in ground / existing pipes / on wall and making connection with telephone main junction box ( mdf ) including supports and all accessories as required 1185 10 pair cable unarmoured 1186 subhead ii supply & installation of fittings 1187 supplying of following box type fl. fitting made out of crca sheet finished in antirust treated non yellowing super white stove enamelled paint duly wired with copper wound heavy duty choke starter holder, starter but without lamp complete etc. as reqd. 1188 mounting rail for tled lamps 1600 lumens ( tmc 501 p 1xt led with essential led 18w tube ) 1189 supplying of wall bracket light fittings suitable for 11 / 13 w cfl lamp. the fitting shall be made up of m.s. powder coated provided with integral ballast, frosted glass and 1 no. 11 / 13 wlamp duly wired upto the connector block complete as required. ( decon cat. no.05aam ) 1190 supplying of ceiling light fittings suitable for 1 x 15 / 20 w led lamp. the fitting shall be made up of m.s. powder coated provided with electronic ballast, 1 no. 15 / 20 w led lamp duly wired upto the connector block etc. complete as required. 1191 cirrus mini pro 15 / 20 watt & 1100 / 1600 lumens ( philips sm200c led11s 6500 psu od wh ) 1192 supplying of bulk head fittings suitable for 10 w led lamp complete with ballast & accessories such as glass, wire guard, 60 w cfl lamp etc. complete as required. 1193 endural led bulkhead, 10 w, 600 lumen such as ( philips wt202w led6s cw psu s2 pc ) 1194 supplying of exhaustfan, all complete with mounting ring frame i / c bracket, but without regulator with shutters in the following sizes. ( g.e. alsthom, khaitan & havells company ) 1195 300 mm 4 pole 1196 supplying of 1400 mm sweep a.c. electric ceiling fans, capacitor type with double ball bearing complete with 300 mm down rod, canopies, shackles, blades, but without regulator suitable for operation on 230 / 240 volts, 50 hz, single phase, a.c. supply. ( crompton, khaitan & havells company ) 1197 supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 1198 installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 1199 installation, testing and commissioning of pre wired, light fixture / compact fluorescent fitting of all types, complete with all accessories and tube / lamp etc. directly on ceiling / wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 1200 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 1201 upto 450 mm sweep 1202 extra for fixing the louvers / shutters complete with frame for a exhaust fan of all sizes. 1203 installation, testing and commissioning of wall bracket / ceiling fittings of all sizes and shapes containing upto two gls / cfl / led lamps per fitting, complete with all accessories including connections etc. as required. 1204 supplying and fixing call bell / buzzer suitable for single phase, 230 v, complete as required. 1205 subhead iii distribution board 1206 supplying, installing, testing and commissioning of compartmentalised cubical type meter board for installation of single phase meter. the cubical board shall be made of 2mm thick c.r.c.a sheet, duly phosphatised powder coated complete with connection bus bar and following accessories mounted in it. 1207 meter board 1208 incoming : 1209 40a tp mccb having breaking capacity 25 ka 1 no. 1210 outgoing : 1211 space for single phase energy meter 4 nos. 1212 25 amp dp mcb 4 nos. 1213 supplying, installing, testing & commissioning of single phase electronic energy meter, tested as per electricity boards requirement. 1214 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 1215 12 way, spn 1216 supplying and fixing following rating, double pole, 240 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 1217 40 amps 1218 supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. asrequired. 1219 25 amps 1220 supplying of xlpe insulated, pvc sheathed 1.1 kv grade aluminium conductor heavy duty armoured cable as per is : 7098 of size : 1221 4 x 16 sq.mm. 1222 providing, laying and fixing following dia rcc pipe np2 class ( light duty ) in ground complete with rcc collars, jointing with cement mortar 1:2 ( 1 cement : 2 fine sand ) including trenching ( 75 cm deep ) and refilling etc. as required for crossing road / walls 1223 100 mm dia 1224 supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 1225 single pole 1226 subhead iv earthing 1227 earthing with g.i. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. 1228 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re filling as required. 1229 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 1230 subhead v lightning conductor 1231 providing and fixing of lightning conductor finial, made of 25mm dia 300 mm long, g.i. tube, having single prong at top, with85 mm dia 6 mm thick g.i. base plate including holes etc.complete as required. 1232 jointing copper / g.i. tape ( with another copper / g i tape, base of the finial or any other metallic object ) by riveting / nut bolting / sweating and soldering etc as required. 1233 fixing of copper / g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( for horizontal run ) 1234 fixing of copper / g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( for vertical run ) 1235 providing and fixing testing joint, made of 20 mm x 3 mm thickg.i. strip, 125 mm long, with 4 nos. of g.i. bolts, nuts, chucknuts and spring washers etc. complete as required. 1236 laying copper / g.i. tape 32 mm x 6 mm from earth electrodedirectly in ground as required 1237 leveling 1238 2.00 mtr. width. pathway 1239 earth work in excavation by mechanical means ( hydraulic excavator ) / manual means over areas ( exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan ) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. 1240 all kinds of soil 1241 filling available excavated earth ( excluding rock ) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 1242 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. all work upto plinth level. 1243 1:5:10 ( 1 cement : 5 coarse sand ( zone iii ) : 10 graded stone aggregate 40 mm nominal size ) . 1244 c / s for mass concrete 1245 providing and laying 60mm thick faciory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved s;ze, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of engineer in charge. 1246 providing and laying at or near ground level factory made kerb stone of m 25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 ( 1 cement: 3 coarse sand ) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5mm ) , including making drainage opening wherever required complete etc. as per direction of engineer in charge ( length of finished kerb edging shall be measured for payment ) . ( precast c.c. kerb stone shall be approved by engineer in charge ) . 1247 15 mm plaster 1.4 1248 preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re rolling the sub grade and disposal of surplus earth with lead upto 50 metres. 1249 supplying and stacking at site. 1250 90 mm to 45 mm size stone aggregate 1251 63 mm to 45 mm size stone aggregate 1252 stone screening 13.2 mm nominal size 1253 stone screening 11.2 mm nominal size 1254 red bajri 1255 moorum 1256 providing and applying tack coat using hot straight run bitumen of grade vg 10, including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications : 1257 on w.b.m. @ 0.75 kg / sqm 1258 2.5 cm premix carpet surfacing with 2.25 cum and 1.12 cum of stone chippings of 13.2 mm and 11.2 mm size respectively per 100 sqm and 52 kg and 56 kg of hot bitumen per cum of stone chippings of 13.2 mm and 11.2 mm size respectively, including a tack coat with hot straight run bitumen, including consolidation with road roller of 6 to 9 tonne capacity etc. complete ( tack coat to be paid for separately ) . 1259 with paving asphalt grade vg 10 heated and then mixed with solvent at the rate of 70 grams per kg of asphalt 1260 providing and laying seal coat of premixed fine aggregate ( passing 2.36 mm and retained on 180 micron sieve ) with bitumen using 128kg of bitumen of grade vg 10 bitumen per cum of fine aggregate and 0.60 cum of fine aggregate per 100 sqm of road surface, including rolling and finishing with road roller all complete. 1261 laying, spreading and compacting stone aggregate of specified sizes to wbm specifications in uniform thickness, hand picking, rolling with 3 wheeled road / vibratory roller 8 10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density . 1262 qty same as 63 45 mm size stone aggregate 1263 qty same as 90 45 mm size stone aggregate 1264 providing and laying at or near ground level factory made kerb stone of m 25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 ( 1 cement: 3 coarse sand ) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5mm ) , includingmaking drainage opening wherever required complete etc. as per direction of engineer in charge ( length of finished kerb edging shallbe measured for payment ) . ( precast c.c. kerb stone shall be approved by engineer in charge ) . 1265 excavating, supplying and filling of local earth ( including royalty ) by mechanical transport upto a lead of 5km also including ramming andwatering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 1266 all kinds of soil 1267 total cost for 35.00 sqm 1268 external water supply 1269 external fresh water supply 1270 excavating trenches upto 1.5 meter depth in all kind ofsoil of required width for pipes. including excavation for sockets and dressing of sides ramming of bottoms including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m or as directed at site by engg in charge. 1271 all kinds of soil 1272 pipes, cables etc, not exceeding 80 mm dia. 1273 providing and fixing chlorinated polyvinyl chloride ( cpvc ) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings. this includes jointing of pipes & fittings with one step cpvc solvent cement, trenching, refilling & testing of joints complete as per direction of engineer in charge : external work 1274 external work 1275 25 mm dia nominal bore 1276 for vertical 1277 type 2 ( g ) ( 3+5 ) = 8 meter 1278 type guest house ( 3+5 ) = 8 meter 1279 32 mm dia nominal bore for horizontal surface 1280 for vertical 1281 type iii ( 3+5 ) = 8meter 1282 type ii ( 3x3+5+3+5 ) = 22 meter 1283 40 mm dia nominal bore 1284 50 mm dia nominal bore 1285 providing and fixing gun metal non return valve of approved quality ( screwed end ) : 1286 32 mm nominal bore 1287 horizontal 1288 construction of masonary chamber60x60x75 inside in brickwork cement mortar 1.6 1289 with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 1290 providing and fixing c.i. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete ( the tail pieces, tapers etc if required will be paid separately ) : 1291 50 mm dia 1292 50 mm dia 1293 100 mm dia 1294 providing and fixing gun metal gate valve with c.i. wheel of approved quality ( screwed end ) : 1295 25 mm nominal bore 1296 32 mm nominal bore 1297 40 mm nominal bore 1298 50 mm nominal bore 1299 providing and laying in position cement concreteof specified grade excluding the cost of centering and shuttering ( for thrust blocks at bends and junctions of water lines ) by 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone agg. 20 mm nominal size ) 1300 providing and fixing g.i. union in gi pipe including cutting and threading the pipe and making long screws etc. complete ( new work ) 1301 25 mm nominal bore 1302 32 mm nominal bore 1303 40 mm nominal bore 1304 50 mm nominal bore 1305 providing and fixing in position pre cast r.c.c. manhole cover and frame of required shape and approved quality 1306 ld 2.5 1307 rectangular shape 600*450 mm internal dimensions 1308 external sewer line 1309 external sewer line 1310 earth work in excavation by mechanical means ( hydraulic excavator ) / manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 sqm on plan ) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1311 excavating trenches of required width for pipes, cable, etcincluding excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.50m including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. 1312 all kinds of soil 1313 pipes cables etc. exceeding 80 mm dia. but not exceeding 300mm dia. 1314 pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm 1315 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level 1316 1:4:8 ( 1 cement : 4 coarse sand ( zone iii ) : 8 graded stone aggregate 40 mm nominal size ) 1317 providing and laying non pressure np2 class ( light duty ) r.c.c. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete : 1318 150 mm dia. r.c.c. pipe 1319 250 mm dia. r.c.c. pipe 1320 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 1321 1:5:10 ( 1 cement : 5 coarse sand ( zone iii ) : 10 graded stone aggregate 40 mm nominal size ) . 1322 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) 1323 providing and laying non pressure np2 class ( light duty ) r.c.c. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1cement : 2 fine sand ) including testing of joints etc. complete : 1324 300 mm dia. r.c.c. pipe 1325 450 mm dia. r.c.c. pipe 1326 centering and shuttering including strutting, propping etc. and removal of form for : 1327 foundations, footings, bases of columns, etc. for mass concrete. 1328 constructing brick masonry manholein cement mortar 1 : 4 ( 1 cement : 4 coarse sand ) with rcc top slab with 1 : 2 : 4 mix ( 1 cement : 2 coarse sand : 4gradestone aggregate 20mm nominal size ) ; foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 gradedstoneaggregate40 mm nominalsize ) insideplastering 12 mm thickwith cementmortar 1:3 ( 1cement 3 coarse sand ) finished with a floating coat of neat cement and makingchannels incementconcrete 1:2:4 ( 1cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size ) finishd with a floating coat ofneatcement completeasper standard design 1329 inside size 90 x 80 cm & 45 cmdeep including ci cover with frame ( light duty ) 455 x 610mm internal dimensions, total weight of cover & frame to be not lessthan 38 kg ( weight of cover 23 kg and weight of frame 15 kg ) 1330 with common burnt clay f.p.s. ( non modular ) bricks of classic designation 7.5 1331 inside size 120 x 90 cm & 90 cmdeep including ci cover with frame ( medium duty ) 560mm internal diameter, total wt. of cover & frame to be not lessthan 208 kg ( wt. of cover 108 kg and wt. of frame 100 kg ) 1332 with common burnt clay f.p.s. ( non modular ) bricks of classic designation 7.5 1333 extra for depth for manholes: 1334 size 90 x 80 cm 1335 with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 1336 size 120 x 90 cm 1337 with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 1338 providing and fixing square mouths. w. gully trapclass sp 1 complete with c.i. gratingbrickmasonry chamber with water tight ci cover with frame of 300 x 300 mm size ( inside ) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 1339 180 x 150 mm. size p type 1340 with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 1341 constructing brick masonry circular type manhole 0.91m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 ( 1 cement :4 coarse sand ) , in side cement plaster 12 mm thick with cement mortar 1:3 ( 1cement : 3 coarse sand ) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size ) , and making necessary channel in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) finished with a floating coat of neat cement, all complete as per standard design : 1342 circular manhole internal dia 0.91mtr. 1343 constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 ( 1 cement :4 coarse sand ) inside cement plaster 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand ) finished with a floating coat of neat cement foundation concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) and making necessary channel in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement, all complete as per standard design : 1344 1.68 m deep with sfrc cover and frame ( heavy duty hd 20 grade designation ) 560 mm internal diameter conforming to i.s. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) including centering, shuttering all complete. ( excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately ) : 1345 with sewer bricks conforming is : 4885 1346 extra depth for circular type manhole 1.22 m internal dia ( at bottom ) beyond 1.68 m to 2.29 m : 1347 12 mm cement plaster of mix: 1348 1:4 ( 1 cement: 4 fine sand ) 1349 constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 ( 1 cement : 4 coarse sand ) inside cement plaster 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand ) finished with a floating coat of neat cement, foundation concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) and making necessary channel in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement, all complete as per standard design : 1350 2.30 m deep with sfrc cover and frame ( heavy duty hd 20 grade designation ) 560 mm internal diameter conforming to i.s. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 ( 1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) including centering, shuttering all complete. ( excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately ) : 1351 with sewer bricks conforming is : 4885 1352 extra depth for circular type manhole 1.52 m internal dia ( at bottom ) beyond 2.30 m : 1353 with sewer bricks conforming is : 4885 1354 12 mmcement plaster of mix 1355 1:4 ( 1 cement : 4 coarse sand ) . 1356 providing m.s. foot restsorange colour safety footrest 1357 with 20x20 mm square bar 1358 filling available excavated earth ( excluding rock ) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 1359 drain ( 230mm x 150mm ) 1360 earth work in excavation by mechanical means ( hydraulic excavator ) / manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 sqm on plan ) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1361 all kinds of soil. 1362 filling available excavated earth ( excluding rock ) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ( 40% of item no. 1 ) 1363 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 1364 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) 1365 1:5:10 ( 1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size ) . 1366 brick work with f.p.s. bricks of class designation 75 in foundation and plinth in: 1367 cement mortar 1:6 ( 1 cement : 6 coarse sand ) 1368 12 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 1369 1:4 ( 1 cement: 4 fine sand ) 1370 drain ( 300mm x 450mm ) 1371 earth work in excavation by mechanical means ( hydraulic excavator ) / manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 sqm on plan ) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1372 all kinds of soil. 1373 filling available excavated earth ( excluding rock ) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ( 40% of item no. 1 ) 1374 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 1375 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) 1376 1:5:10 ( 1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size ) 1377 brick work with f.p.s. bricks of class designation 75 in foundation and plinth in: 1378 cement mortar 1:6 ( 1 cement : 6 coarse sand ) 1379 12 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 1380 1:4 ( 1 cement: 4 fine sand ) 1381 h.t. / l.t. panel & feeder pillars 1382 sub feeder panel 1383 incoming 1384 mccb 200a 35ka tpn 1385 indication light 1386 bus bar feeders 1387 200amp alu.bus bar tpn 1388 out going 1389 g / d phase b mccb 125a 35ka tpn 1390 b / d phase b mccb 125a 35ka tpn 1391 type 3 ( g+1 ) mccb 63a 35ka tpn 1392 type 5 mccb 32a 35ka tpn 1393 guest house mccb 32a 35ka tpn 1394 type 3 ( g+2 ) mccb 63a 35ka tpn 1395 type 2 ( g+2 ) mccb 63a 35ka tpn 1396 spare 1397 emergency section 1398 incoming 1399 mcb 125a 63ka tpn 1400 out going 1401 b / d phase b mcb 63a 35ka dp 1402 g / d phase b mcb 63a 35ka dp 1403 type 3 ( g+1 ) mcb 32a 35ka dp 1404 type 5 mcb 32a 35ka dp 1405 guest house mcb 32a 35ka dp 1406 type 3 ( g+2 ) mccb 32a 35ka dp 1407 type 2 ( g+1 ) mccb 32a 35ka dp 1408 type 2 ( g ) mccb 32a 35ka dp 1409 spare 1410 enclosure 1411 panel body fabricated in 14 / 16 swg crca sheet , powder coa ted in siemence grey colour complete in all respects universal gland plates. 1412 meter panel ( type 2 / type3 / guest house ) 1413 incoming 1414 mcb 32a 10 ka tpn 1415 indication light r, y, b 1416 bus bar feeders 1417 100amp alu.bus bar tpn 1418 out going 1419 single phase energy meter 1420 mcb 25a dp 1421 emergency section 1422 incoming 1423 mccb 32a dp 1424 out going 1425 16a dp 1426 enclosure 1427 panel body fabricated in 14 / 16 swg crca sheet , powder coa ted in siemence grey colour complete in all respects universal gland plates. 1428 meter panel ( type 3 block b ) 1429 incoming 1430 mcb 63a 10 ka tpn 1431 indication light r, y, b 1432 bus bar feeders 1433 100amp alu.bus bar tpn 1434 out going 1435 single phase energy meter 1436 mcb 25a dp 1437 emergency section 1438 incoming 1439 mccb 32a dp 1440 out going 1441 16a dp 1442 enclosure 1443 panel body fabricated in 14 / 16 swg crca sheet , powder coa ted in siemence grey colour complete in all respects universal gland plates. 1444 type ii single story only mcb & meter without bus bar 1445 external electrification 1446 supply installation, testing and commissioning of external post top lantern with following and complete as required. 1447 6m high ( 5.0m above ground ) 65mm dia gi pole as approved, adopting socket at top for fixture mentioned below, base plate 300x300x6mm and provision for mounting junction box etc. 1 set 1448 erection of pole in cement concrete 400x400x1000mm deep 1:3:6 ratio cement concrete foundation including excavation , refilling, secured with holding clamps, bolts, nuts, alighnment of poles casting etc. including 100 mm thick lean concrete shall be provided at the bottom. 1449 led type 50 watt ( street light ) light fittings of all types with allaccessories. 1450 suitable size control box with 1 no. incoming and 2 nos. outgoing terminals and 2 nos. tap out terminal with 1 no.5a hrc fuses complet 1 set 1451 suitable number ( s ) 40mm dia class b gi pipes ( s ) from above control box to upto 0.5 meter below ground level for power cable entry. 1452 lt cables 1453 supply of following size of 1.1 kv grade multicore aluminium cunductor pvc sheathed armoured cable as per is 1554. 1454 4 core 25 sqmm 1455 4 core 16 sqmm 1456 2 core 16 sqmm 1457 2 core 10 sqmm 1458 earthingwithgi earth pipe 4.50 meter long 40mm dia including accessories, and providing masonry enclosure with cover plate having lockingarrangement and watering pipe etc.with charcoal or coke and salt complete as required. 1459 earthingwithgi earth plate 600 x 600 x 3mmthickincluding accessories, and providing masonry enclosure with cover plate having lockingarrangement and watering pipe etc.ith watering pipeof 2.7 meter long etc. with charcoal or coke and salt complete as required. ( for mltp & dg body ) 1460 providing and fixing 25 mm x 5 mm copper strips in 40 mm dia g.i.pipe from earth electrode, including connection with brass nut bolts , spring washer, excavation and refilling etc, as required ( copper plate earthing ) 1461 providing and fixing 25 mm x 5 mm gi strip in 40 mm dia g.i.pipe from earth electrode, including connection with brass nut bolts , spring washer, excavation and refilling etc, as required ( copper gi plate earthing ) 1462 providing& layingearth connection from earth electrode with 6 swg dia giwire in 15 mm gi pipe from earth electrode including connection with gi thimbleexcavation and refilling etc as required. ( for gi pipe earthing ofpoles ) 1463 supply & laying of 25 x 5 mm copper earth strip in surface / recess 1464 providing and fixing 25mm x 5 mm g.i. strips on surface or in recess for connections etc. as required 1465 providing andfixing mvdanger noticeplate of200 mm x 150 mm madeofmild steelatleast 2 mm thickandvitreousenameled white on both sides & with inscription in signalred colour on front side as required. ( on 7mts poles & panels ) 1466 lt cables laying 1467 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc / hume / metal pipe as required. 1468 upto 35 sq. mm 1469 above 35 sq. mm and upto 95 sq. mm 1470 above 95 sq. mm and upto 185 sq. mm 1471 above 185 sq. mm and upto 400 sq. mm 1472 supplying and laying of following size dwc hdpe pipe isi marked along with all accessories like socket, bend, couplers etc. conforming to is 14930, part ii complete with fitting and cutting, jointing etc.direct in ground ( 75 cm below ground level ) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 1473 63 mm dia ( od 63 mm & id 51 mm nominal ) 1474 120 mm dia ( od 120 mm & id 103 mm nominal ) 1475 160 mm dia ( od 160 mm & id 135 mm nominal ) sqmm 1476 200 mm dia ( od 200 mm & id 175 mm nominal ) 1477 supplying and making end termination with brass comperession gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required 1478 4 core 25 sqmm 1479 4 core 16 sqmm 1480 3.5 core 240 sqmm 1481 3.5 core 95 sqmm 1482 2 core 50 sqmm 1483 2 core 16 sqmm 1484 2 core 10 sqmm 1485 excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 1486 ordinary rock 1487 pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. 1488 providing and laying non pressure np2 class ( light duty ) r.c.c. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete : 1489 150 mm dia. r.c.c. pipe 1490 earth work in excavation by mechanical means ( hydraulic excavator ) i manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 sqm on plan ) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1491 all kinds of soil.0.00 1.50m 1492 earth work in excavation by mechanical means ( hydraulic excavator ) i manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 sqm on plan ) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1493 all kinds of soil.1.50 3.00m 1494 filling available excavated earth ( excluding rock ) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 1495 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 1496 1:5:10 ( 1 cement : 5 coarse sand ( zone iii ) : 10 graded stone aggregate 40 mm nominal size ) . 1497 providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement all work up to plinth level: 1498 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size ) 1499 centering and shuttering including strutting, propping etc. and removal of form for: 1500 foundations, footings, bases of columns, etc. for mass concrete. 1501 walls ( any thickness ) including attached pilasters, butteresses, plinth and string courses etc. 1502 suspended floors, roofs, landings, balconies and access platform. 1503 lintels, beams, plinth beams, girders, bressumers and cantilevers. 1504 edges of slabs and breaks in floors and walls. 1505 under 20 cm wide 1506 reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete. 1507 thermo mechanically treated bars. 1508 cement concrete flooring 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate ) finished with a floating coat of neat cement, includingcement slurry, but excluding the cost of nosing of steps etc. complete. 1509 40 mm thick with 20 mm nominal size stone aggregate 1510 6 mm cement plaster of mix : 1511 1:3 ( 1 cement : 3 fine sand ) 1512 providing and fixing in position pre cast r.c.c. manhole cover and frame of required shape and approved quality 1513 hd 20 1514 circular shape 560 mm internal diameter 1515 providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per is : 10910 on 12mm dia steel bar conforming to is : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) complete as per design. 1516 providing and fixing soil, waste and vent pipes 1517 100 mm dia. 1518 centrifugally cast ( spun ) iron socketed pipe as per is: 3989. 1519 making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and s.w. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. 1520 with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 1521 dismantling work including credti items i.e bricks steels...

Uttar Pradesh Projects Corporation Limited - Bihar

42835557 construction of phase b works at jnv gaya ii ( bihar ) 1 earth work 2 earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 3 all kinds of soil 4 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 5 supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 6 excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 7 concrete work 8 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 9 1:5:10 (1 cement : 5 coarse sand (zone iii) : 10 graded stone aggregate 40 mm nominal size) 10 providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : 11 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). 12 providing and laying damp proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone iii): 4 graded stone aggregate 12.5mm nominal size) 13 providing & applying a coat of residual petroleum bitumen of grade of vg 10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 14 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 15 reinforcedcementconcrete 16 centering and shuttering including strutting, propping etc. and removal of form for all heights: 17 foundations, footings, bases of columns, etc. for mass concrete 18 columns, pillars, piers, abutments, posts and struts 19 small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like 20 edges of slabs and breaks in floors and walls 21 under 20 cms wide 22 suspended floors, roofs, landings, balconies and access platform. 23 lintels, beams, plinth beams, girders, bressumers and cantilevers. 24 providing precast cement concrete jali 1:2:4 (1 cement : 2 coarse sand(zone iii) : 4 graded stone aggregate 6mm nominal size), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing with cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits. 25 50 mm thick 26 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 27 thermo mechanically treated bars of grade fe 500d or more. 28 add for plaster drip course/ groove in plastered surface or moulding to r.c.c. projections. 29 providing and laying in position machine batched and machine mixed design mix m 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per is: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of engineer in charge.“(note : cement content considered in this item is @ 330 kg/cum.“excess/ less cement used as per design mix is payable/recoverable separately). 30 all works upto plinth level 31 all works above plinth level upto floor v level 32 add for using extra cement in the items of design mix over and above the specified cement content therein. 33 brick work 34 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in foundation and plinth in: 35 cement mortar 1:6 (1 cement : 6 coarse sand) 36 providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick aac blocks in super structure above plinth level up to floor v level with rcc band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of engineer in charge. (the payment of rcc band and reinforcement shall be made for seperately).: 37 half brick masonry with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level. 38 cement mortar 1:4 (1 cement :4 coarse sand) 39 extra for providing and placing in position 2 nos 6mm dia. m.s. bars at every third course of half brick masonry. 40 brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand). 41 marble work 42 providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 43 raj nagar plain white marble/ udaipur green marble/ zebra black marble 44 area of slab over 0.50 sqm 45 granite of any colour and shade 46 area of slab over 0.50 sqm 47 providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer in charge. 48 marble work 49 granite work 50 extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 51 wood work & pvc work 52 float glass panes 53 4mm thick glass pane (weight not less than 10 kg/sqm 54 extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. (area of opening for glass panes excluding portion inside rebate shall be measured). 55 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 56 35 mm thick including isi marked stainless steel butt hinges with necessary screws 57 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 58 extra for cutting rebate in flush door shutters (total area of the shutter to be measured). 59 providing and fixing wire gauge shutters using galvanized m.s. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 60 35 mm thick shutters 61 kiln seasoned and chemically treated hollock wood 62 providing and fixing fly proof galvanized m.s. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. 63 with 12 mm mild steel u beading 64 providing and fixing isi marked oxidised m.s. single acting spring hinges with necessary screws etc. complete : 65 150 mm 66 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete. 67 250 mm weighing not less than 150 gms 68 providing and fixing aluminium sliding door bolts, isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 69 250x16 mm 70 providing and fixing aluminium tower bolts, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 71 200x10 mm 72 providing and fixing aluminium hanging floor door stopper, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. 73 twin rubber stopper 74 providing and fixing factory made upvc white colour sliding glazed window upto 1.50 m in height dimension comprising of upvc multi chambered frame with in built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to upvc profile), appropriate dimension of upvc extruded glazing beads and upvc extruded interlocks, epdm gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), g.i fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of engineer in charge. (single / double glass panes, wire mesh and silicon sealent shall be paid separately). variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 75 three track three panels sliding window with fly proof s.s wire mesh (two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (area of window above 1.75 sqm). 76 steel work 77 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 78 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 79 providing and fixing t iron frames for doors, windows and ventilators of mild steel tee sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 80 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 81 providing and fixing circular/ hexagonal cast iron or m.s. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick m.s. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ m.s. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. clamp shall be made of 12 mm dia m.s. bar bent to shape as per standard drawing. 82 providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. 83 m.s. tube 84 providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 85 4.0 mm thick glass panes 86 flooring 87 providing and laying c.c. pavement of mix m 25 with ready mixed concrete from batching plant. the ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of engineer incharge. (the panel shuttering work shall be paid for separately). 88 (note: cement content considered in this item is @ 330 kg/cum. excess/less cement used as per design mix is payable/ recoverable separately). 89 kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 90 25 mm thick. 91 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 92 extra for pre finished nosing in treads of steps of kota stone/ sand stone slab. 93 extra for kota stone/ sand stone in treads of steps and risers using single length up to 1.05 metre. 94 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 95 providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 96 size of tile 600x600 mm 97 providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. 98 size of tile 600x600 mm 99 providing and laying 60mm thick faciory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved s;ze, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of engineer in charge. 100 roofing 101 providing and laying brick tiles over mumty roofs, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat: 12.19.1 with common burnt clay f.p.s. (non modular) brick tilesof class designation 10 102 making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over p.v.c. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 103 finishing 104 12 mm cement plaster of mix 105 1:6 (1 cement: 6 coarse sand) 106 15 mm cement plaster on rough side of single or half brick wall of mix: 107 1:6 (1 cement: 6 coarse sand) 108 cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 109 20 mm cement plaster 110 white washing with lime to give an even shade : 111 new work (three or more coats) 112 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 113 new work (two or more coats) over and including water thinnable priming coat with cement primer 114 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 115 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 116 applying priming coat: 117 with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 118 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 119 painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 120 two or more coats on new work 121 painting with black anti corrosive bitumastic paint of approved brand and manufacture to give an even shade : 122 two or more coats on new work 123 water proofing 124 providing and laying water proofing treatment to vertical andhorizontal surfaces of depressed portions of w.c., kitchen and the like consisting of: 125 ist course of applying cement slurry @ 4.4 kg/sqm mixedwith water proofing compound conforming to is 2645 inrecommended proportions including rounding off junction ofvertical and horizontal surface. 126 iind course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. 127 iiird course of applying blown or residual bitumen applied hotat 1.7 kg. per sqm of area. 128 ivth course of 400 micron thick pvc sheet. (overlaps at jointsof pvc sheet should be 100 mm wide and pasted to eachother with bitumen @ 1.7 kg/sqm). 129 providing and laying in situ seven course water proofing treatment with app (atactic poly propylene) modified polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to is : 702, 3rd and 5th layers of roofing membrane app modified polymeric membrane 1.5 mm thick of 2.25 kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron hmhdpe film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron hmhdpe film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately). 130 non shedule items 131 providing and fixing aluminium handles, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 132 150 mm 133 providing and fixing aluminium door buffer of approved make, design and colour with necessary screws etc all complete as directed and specified by the engineer in charge : 134 providing and laying 1st quality ceramic glazed anti skid floortiles of size 300x300 mm (thickness to be specified by the manufacturer) conforming to is:15622 in all colours, shades, sizes as approved over 20 mm thick bed of cement mortar 1: 4 (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc complete in all respects as per specifications/drawings and to the entire satisfaction to the architect. 135 earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 136 all kinds of soil. 137 excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 138 all kinds of soil 139 pipes, cables etc, not exceeding 80 mm dia. 140 pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 141 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 142 roofing 143 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 144 110 mm diameter 145 providing and fixing on wall face unplasticised pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 146 coupler 147 110 mm 148 bend 87.5° 149 110 mm bend 150 shoe (plain) 151 110 mm shoe 152 providing and fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with m.s. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 153 110 mm 154 providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 155 sanitary installations 156 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 157 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 158 providing and fixing white vitreous china pedestal type water closet (european type) with seat and lid, 10 litre low level white vitreous china flushing cistern & c.p. flush bend with fittings & c.i. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 159 w.c. pan with isi marked black solid plastic seat and lid 160 providing and fixing wash basin with c.i. brackets, 15 mm c.p. brass pillar taps, 32 mm c.p. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 161 white vitreous china flat back wash basin size 550x 400 mm with single 15 mm c.p. brass pillar tap 162 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is: 13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 163 kitchen sink with drain board 164 510x1040 mm bowl depth 250 mm 165 extra for using coloured pedestal type w.c pan (european type) with low level cistern of same colour instead of white vitreous china w.c pan and cistern. 166 providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with c.p. brass screws and washers complete. 167 providing and fixing toilet paper holder : 168 vitreous china 169 providing and fixing soil, waste and vent pipes : 170 100 mm dia. 171 centrifugally cast (spun) iron socket & spigot (s&s) pipe as per is: 3989 172 75mm diameter 173 centrifugally cast (spun) iron socketed pipe as per is: 3989 174 providing and fixing m.s. holder bat clamps of approved design to sand cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : 175 for 100 mm dia. pipe 176 for 75 mm dia. pipe 177 providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 178 100 mm 179 sand cast iron s&s as per is 3989 180 75 mm 181 sand cast iron s&s as per is 3989 182 providing and fixing plain bend of required degree. 183 100 mm 184 sand cast iron s&s as per is : 3989 185 75 mm 186 sand cast iron s&s as per is 3989 187 providing and fixing heel rest sanitary bend 188 100 mmdia 189 sand cast iron s&s as per is 3989 190 75 mm dia 191 sand cast iron s&s as per is 3989 192 providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3mm thick,bolts and nuts complete. 193 100x100x100mm 194 sand cast iron s&s as per is 3989 195 75x75x75mm 196 sand cast iron s&s as per is 3989 197 providing and fixing single equal plain junction of required degree 198 100x100x100mm 199 sand cast iron s&s as per is 3989 200 75x75x75mm 201 sand cast iron s&s as per is 3989 202 providing and fixing door piece, insertion rubber washer 3mm thick, bolts & nuts complete : 203 100 mm 204 sand cast iron s&s as per is 3989 205 75 mm 206 sand cast iron s&s as per is 3989 207 providing and fixing terminal guard : 208 100 mm 209 sand cast iron s&s as per is 3989 210 75 mm 211 sand cast iron s&s as per is 3989 212 providing and fixing collar : 213 100 mm 214 sand cast iron s&s as per is 3989 215 75 mm 216 sand cast iron s&s as per is 3989 217 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : 218 100 mm 219 75 mm 220 providing and fixing m.s. stays and clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter : 221 100 mm 222 75 mm 223 providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 224 100 mm inlet and 100 mm outlet 225 sand cast iron s&s as per is: 1729 226 cutting chases in brick masonry walls for following diameter sand cast iron/ centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : 227 100 mm dia 228 painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work : 229 75 mm diameter pipe 230 providing and fixing ptmt waste coupling for wash basin and sink, of approved quality and colour. 231 waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms 232 providing and fixing ptmt bottle trap for wash basin and sink. 233 bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms 234 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 235 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour. 236 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 237 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is: 13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 238 kitchen sink with drain board 239 510x1040 mm bowl depth 250 mm 240 providing and fixing 8mm dia c.p / s.s jet with flexible tube upto1 metre long with s.s triangular plate to eureopean type w.c of quality and make as approved by engineer in charge. 241 providing and fixing g.i. pipes complete with g.i. fittings including trenching & refilling. 242 external work 243 32mmdia nominal bore 244 40mmdia nominal bore 245 water supply 246 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 247 internal work exposed on wall 248 20 mm nominal outer dia pipes 249 25 mm nominal outer dia pipes 250 32 mm nominal outer dia pipes 251 40 mm nominal outer dia pipes 252 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 253 concealed work, including cutting chases and making good the walls etc. 254 15 mm nominal outer dia pipes 255 20 mm nominal outer dia pipes 256 25 mm nominal outer dia pipes 257 32 mm nominal outer dia pipes 258 making connection of g.i. distribution branch with g.i. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 259 25 to 40 mm nominal bore 260 providing and fixing brass stop cock of approved quality : 261 15 mm nominal bore 262 20 mm nominal bore 263 providing and fixing gun metal gate valve with c.i. wheel of approved quality (screwed end) : 264 25mm nominal bore 265 32mm nominal bore 266 40mm nominal bore 267 providing and fixing ball valve (brass) of approved quality, high or low pressure, with plastic floats complete : 268 25 mm nominal bore 269 providing and fixing brass ferrule with c.i. mouth cover including boring and tapping the main : 270 25 mm nominal bore 271 providing and fixing uplasticised pvc connection pipe with brass unions : 272 45 cm length 273 15 mm nominal bore 274 providing and fixing c.p. brass shower rose with 15 or 20 mm inlet : 275 100 mm diameter 276 providing and placing on terrace (at all floor levels) polyethylene water storage tank, is : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 277 rectangular tank 278 providing and fixing c.p. brass bib cock of approved quality conforming to is:8931 : 279 15 mm nominal bore 280 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 281 15 mm nominal bore 282 providing and fixing c.p. brass stop cock (concealed) of standard design and of approved make conforming to is:8931. 283 15 mm nominal bore. 284 providing and fixing c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 285 15 mm nominal bore 286 providing and fixing ptmt grating of approved quality and colour. 287 circular type. 288 100 mm nominal dia. 289 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 290 sewarage & drainage 291 providing, laying and jointing glazed stoneware pipes class sp 1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 292 100 mm diameter 293 150 mm diameter 294 providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all round s.w. pipes including bed concrete as per standard design : 295 100 mm diameter s.w. pipe 296 150 mm diameter s.w. pipe 297 providing and fixing square mouth s.w. gully trap class sp 1 complete with c.i. grating brick masonry chamber with water tight c.i. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70kg as per standard design: 298 180 x 150 mm size p type 299 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 300 constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with r.c.c. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : 301 inside size 90x80 cm and 45 cm deep including c.i. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : 302 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 303 extra for depth for manholes : 304 size 90x80 cm 305 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 306 providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per is : 10910, on 12 mm dia steel bar conforming to is: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 307 making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 308 for pipes 100 to 250 mm diameter 309 providing, laying and jointing non pressure np2 class (light duty)rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 310 150 mm dia rcc pipe 311 250 mm dia rcc pipe 312 non shedule items 313 providing and fixing concealed single leverbath & overhead shower mixer of hindware make and model no.(f360019cp) respectively or equivalent approved make as approved byengineer in charge. 314 providing & fixing sink mixer with swinging casted spout (wall mounted jaquar model con 309 kn)/approved equal with 450mm long copper pipes & brass nuts. 315 providing and fixing c.p. brass grab bar(600mm long) fixed with c.p. brass screwsincluding all fittings complete.jaquar model no. ahs 1507/approve equal. 316 subhead i wiring 317 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. 318 group c 319 wiring for light/ power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 320 wiring for light/ power plug with 4x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 nos. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 321 supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 322 4 module (125 mmx75 mm) 323 supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 324 15/16 a switch 325 3 pin 5/6 a socket outlet 326 telephone socket outlet 327 tv antenna socket outlet 328 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 329 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire 330 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 331 2 x 10 sq. mm + 1 x 6 sq. mm earth wire 332 4 x 4 sq. mm + 2 x 4 sq. mm earth wire 333 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface/ recessed steel/ pvc conduit as required. 334 supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 335 25 mm 336 supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 337 1 or 2 module (75 mmx75 mm) 338 supplying and drawing following pair 0.5 mm dia frls pvc insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ pvc conduit as required. 339 2 pair 340 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 341 20 mm 342 25 mm 343 providing and fixing in position 2mm thick m.s. telephone junction box of size suitable for fixing of following krone tag block with key lock arrangement. also provide clamps for fixing tag blocks. 344 10 pair telephone tag blockwith box 345 supplying, laying of 10 pair unarmoured pvc insulated copper conductor (atc) telephone cable in ground/existing pipes/on wall and making connection with telephone main junction box (mdf) including supports and all accessories as required 346 10 pair cable unarmoured 347 subhead ii supply & installation of fittings 348 supplying of following box type fl. fitting made out of crca sheet finished in antirust treated non yellowing super white stove enamelled paint duly wired with copper wound heavy duty choke starter holder, starter but without lamp complete etc. as reqd. 349 mounting rail for tled lamps 1600 lumens (tmc 501 p 1xt led with essential led 18w tube) 350 sereno 42 watt 2950 lumens philips sp824 p led 30s 5000 gr oa 351 supplying of wall mounted suitable for 1300 lumens complete with ballast & accessories such as wire guard etc. complete as required. 352 15w astra surface & wall mounted 1300 lumens ( philips bn150w led13s 6500 pse od gr ) 353 supplying of wall bracket light fittings suitable for 11 / 13 w cfl lamp. the fitting shall be made up of m.s. powder coated provided with integral ballast, frosted glass and 1 no. 11 / 13 wlamp duly wired upto the connector block complete as required. (decon cat. no.05aam) 354 supplying of ceiling light fittings suitable for 1 x 15/20 w led lamp. the fitting shall be made up of m.s. powder coated provided with electronic ballast, 1 no. 15/20 w led lamp duly wired upto the connector block etc. complete as required. 355 cirrus mini pro 15 / 20 watt & 1100 /1600 lumens (philips sm200c led11s 6500 psu od wh) 356 supplying of bulk head fittings suitable for 10 w led lamp complete with ballast & accessories such as glass, wire guard, 60 w cfl lamp etc. complete as required. 357 endural led bulkhead, 10 w, 600 lumen such as (philips wt202w led6s cw psu s2 pc) 358 supplying of exhaustfan, all complete with mounting ring frame i/c bracket,but without regulator with shutters in the following sizes. (g.e. alsthom, khaitan & havells company) 359 300 mm 4 pole 360 supplying of 1400 mm sweep a.c. electric ceiling fans, capacitor type with double ball bearing complete with 300 mm down rod, canopies, shackles, blades, but without regulator suitable for operation on 230 / 240 volts, 50 hz, single phase, a.c. supply. (crompton, khaitan & havells company) 361 supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 362 installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 363 installation, testing and commissioning of pre wired, light fixture / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 364 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 365 upto 450 mm sweep 366 extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. 367 installation, testing and commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two gls/cfl/ led lamps per fitting, complete with all accessories including connections etc. as required. 368 supplying and fixing call bell/ buzzer suitable for single phase, 230 v, complete as required. 369 subhead iii distribution board 370 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/ isolator) 371 6 way (4 + 18), double door 372 supplying and fixing following rating, four pole, 415 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 373 100 a 374 supplying and fixing following rating, four pole, (three phase and neutral), 415 v, residual current circuit breaker (rccb), having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. 375 63 a 376 supplying and fixing following rating, double pole, 240 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 377 40 amps 378 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 379 12 way , double door 380 16 way , double door 381 supplying and fixing following rating, double pole, (single phase and neutral), 240 v, residual current circuit breaker (rccb), having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. 382 25 a 383 40 a 384 supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 385 single pole 386 subhead iv earthing 387 earthing with g.i. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 388 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re filling as required. 389 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 390 subhead v street lighting on building 391 supplying, installing, testing and commissioning of 2 x 36w general purpose flourescent street light fittings with sheet aluminium housing and uv stabilized acrylic cover complete with chokes, starter holders, condensers, reflector cover etc. as reqd. (philips cat no. trc 33 / 236 hpf) (to be fixed directly on wall of building) 392 supplying and fixing of 32 mm dia x 2.00 meter long g.i. pipe (medium class) bracket for mounting of fluorescent / hpmv / hpsv street light fitting on pole including bending the pipe to the required shape, 2 nos. 40 mm x 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. 393 supply of following sizes of frls 1.1 kv stranded compact circular aluminium conductor screened with extruded semi conducting compound, xlpe insulated,al round wire armoured & overall pvc sheathed cableconforming to is to is 7098 (part i) with latest amendments 394 2 x 4 sq.mm 395 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. 396 upto 35 sq. mm 397 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc/ hume/ metal pipe as required. 398 upto 35 sq. mm 399 laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required. 400 upto 35 sq. mm (clamped with 1mm thick saddle) 401 supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required. 402 2 x 6 sq. mm (19mm) 403 supply & fixing of 150x200 mm 60mm deep ms junction box recess or surface on wall with 3mm bakalite cover15 overlapping 15 all sides of junction box & housing 4way 32amps bakelie connector to terminate incoming & outgoing armoured cable & & wiring the light fixture with 3x1.5 sq mm pvc insulated coppwer wire including interconnection ets as reqired .( cost of termination of armoured cable with gland is not to be included as the same is payable under separate item no 5.07 of this subhead) 404 providing, laying and fixing following dia rcc pipe np2 class (light duty) in ground complete with rcc collars, jointing withcement mortar1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required. 405 100 mm dia 406 subhead vi lightning conductor 407 providing and fixing of lightning conductor finial, made of 25mm dia 300 mm long, g.i. tube, having single prong at top, with85 mm dia 6 mm thick g.i. base plate including holes etc.complete as required. 408 jointing copper / g.i. tape (with another copper/ g i tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 409 fixing of copper/ g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for horizontal run) 410 fixing of copper/ g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for vertical run) 411 providing and fixing testing joint, made of 20 mm x 3 mm thickg.i. strip, 125 mm long, with 4 nos. of g.i. bolts, nuts, chucknuts and spring washers etc. complete as required. 412 laying copper/ g.i. tape 32 mm x 6 mm from earth electrodedirectly in ground as required 413 earth work 414 earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 415 all kinds of soil 416 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 417 supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 418 excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 419 concrete work 420 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 421 1:5:10 (1 cement : 5 coarse sand (zone iii) : 10 graded stone aggregate 40 mm nominal size) 422 providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : 423 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). 424 providing and laying damp proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone iii): 4 graded stone aggregate 12.5mm nominal size) 425 providing & applying a coat of residual petroleum bitumen of grade of vg 10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 426 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 427 reinforcedcementconcrete 428 centering and shuttering including strutting, propping etc. and removal of form for all heights: 429 foundations, footings, bases of columns, etc. for mass concrete 430 walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc 431 columns, pillars, piers, abutments, posts and struts 432 small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like 433 edges of slabs and breaks in floors and walls 434 under 20 cms wide 435 suspended floors, roofs, landings, balconies and access platform. 436 lintels, beams, plinth beams, girders, bressumers and cantilevers. 437 providing precast cement concrete jali 1:2:4 (1 cement : 2 coarse sand(zone iii) : 4 graded stone aggregate 6mm nominal size), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing with cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits. 438 50 mm thick 439 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 440 thermo mechanically treated bars of grade fe 500d or more. 441 add for plaster drip course/ groove in plastered surface or moulding to r.c.c. projections. 442 providing and laying in position machine batched and machine mixed design mix m 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per is: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of engineer in charge.“(note : cement content considered in this item is @ 330 kg/cum.“excess/ less cement used as per design mix is payable/recoverable separately). 443 all works upto plinth level 444 all works above plinth level upto floor v level 445 add for using extra cement in the items of design mix over and above the specified cement content therein. 446 brick work 447 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in foundation and plinth in: 448 cement mortar 1:6 (1 cement : 6 coarse sand) 449 providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick aac blocks in super structure above plinth level up to floor v level with rcc band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of engineer in charge. (the payment of rcc band and reinforcement shall be made for seperately).: 450 half brick masonry with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level. 451 cement mortar 1:4 (1 cement :4 coarse sand) 452 extra for providing and placing in position 2 nos 6mm dia. m.s. bars at every third course of half brick masonry. 453 brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand). 454 marble work 455 providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 456 raj nagar plain white marble/ udaipur green marble/ zebra black marble 457 area of slab over 0.50 sqm 458 granite of any colour and shade 459 area of slab over 0.50 sqm 460 providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer in charge. 461 marble work 462 granite work 463 extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 464 wood work & pvc work 465 float glass panes 466 4mm thick glass pane (weight not less than 10 kg/sqm 467 extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. (area of opening for glass panes excluding portion inside rebate shall be measured). 468 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 469 35 mm thick including isi marked stainless steel butt hinges with necessary screws 470 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 471 extra for cutting rebate in flush door shutters (total area of the shutter to be measured). 472 providing and fixing wire gauge shutters using galvanized m.s. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 473 35 mm thick shutters 474 kiln seasoned and chemically treated hollock wood 475 providing and fixing fly proof galvanized m.s. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. 476 with 12 mm mild steel u beading 477 providing and fixing isi marked oxidised m.s. single acting spring hinges with necessary screws etc. complete : 478 150 mm 479 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete. 480 250 mm weighing not less than 150 gms 481 providing and fixing aluminium sliding door bolts, isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 482 250x16 mm 483 providing and fixing aluminium tower bolts, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 484 200x10 mm 485 providing and fixing aluminium hanging floor door stopper, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. 486 twin rubber stopper 487 providing and fixing factory made upvc white colour sliding glazed window upto 1.50 m in height dimension comprising of upvc multi chambered frame with in built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to upvc profile), appropriate dimension of upvc extruded glazing beads and upvc extruded interlocks, epdm gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), g.i fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of engineer in charge. (single / double glass panes, wire mesh and silicon sealent shall be paid separately). variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 488 three track three panels sliding window with fly proof s.s wire mesh (two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (area of window above 1.75 sqm). 489 steel work 490 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 491 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 492 providing and fixing t iron frames for doors, windows and ventilators of mild steel tee sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 493 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 494 providing and fixing circular/ hexagonal cast iron or m.s. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick m.s. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ m.s. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. clamp shall be made of 12 mm dia m.s. bar bent to shape as per standard drawing. 495 providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. 496 m.s. tube 497 providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 498 4.0 mm thick glass panes 499 flooring 500 providing and laying c.c. pavement of mix m 25 with ready mixed concrete from batching plant. the ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of engineer incharge. (the panel shuttering work shall be paid for separately). 501 (note: cement content considered in this item is @ 330 kg/cum. excess/less cement used as per design mix is payable/ recoverable separately). 502 kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 503 25 mm thick. 504 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 505 extra for pre finished nosing in treads of steps of kota stone/ sand stone slab. 506 extra for kota stone/ sand stone in treads of steps and risers using single length up to 1.05 metre. 507 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 508 providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 509 size of tile 600x600 mm 510 providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. 511 size of tile 600x600 mm 512 providing and laying 60mm thick faciory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved s;ze, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of engineer in charge. 513 roofing 514 providing and laying brick tiles over mumty roofs, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat: 12.19.1 with common burnt clay f.p.s. (non modular) brick tilesof class designation 10 515 making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over p.v.c. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 516 finishing 517 12 mm cement plaster of mix 518 1:6 (1 cement: 6 coarse sand) 519 15 mm cement plaster on rough side of single or half brick wall of mix: 520 1:6 (1 cement: 6 coarse sand) 521 cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 522 20 mm cement plaster 523 white washing with lime to give an even shade : 524 new work (three or more coats) 525 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 526 new work (two or more coats) over and including water thinnable priming coat with cement primer 527 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 528 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 529 applying priming coat: 530 with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 531 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 532 painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 533 two or more coats on new work 534 painting with black anti corrosive bitumastic paint of approved brand and manufacture to give an even shade : 535 two or more coats on new work 536 water proofing 537 providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of w.c., kitchen and the like consisting of: 538 ist course of applying cement slurry @ 4.4 kg/sqm mixedwith water proofing compound conforming to is 2645 inrecommended proportions including rounding off junction of vertical and horizontal surface. 539 iind course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. 540 iiird course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. 541 ivth course of 400 micron thick pvc sheet. (overlaps at joints of pvc sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). 542 providing and laying in situ seven course water proofing treatment with app (atactic poly propylene) modified polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to is : 702, 3rd and 5th layers of roofing membrane app modified polymeric membrane 1.5 mm thick of 2.25 kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron hmhdpe film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron hmhdpe film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately). 543 non shedule items 544 providing and fixing aluminium handles, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 545 150 mm 546 providing and fixing aluminium door buffer of approved make, design and colour with necessary screws etc all complete as directed and specified by the engineer in charge : 547 providing and laying 1st quality ceramic glazed anti skid floortiles of size 300x300 mm (thickness to be specified by the manufacturer) conforming to is:15622 in all colours, shades, sizes as approved over 20 mm thick bed of cement mortar 1: 4 (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc complete in all respects as per specifications/drawings and to the entire satisfaction to the architect. 548 earth work 549 earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 550 all kinds of soil. 551 excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 552 all kinds of soil 553 pipes, cables etc, not exceeding 80 mm dia. 554 pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 555 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 556 roofing 557 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 558 110 mm diameter 559 providing and fixing on wall face unplasticised pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 560 coupler 561 110 mm 562 bend 87.5° 563 110 mm bend 564 shoe (plain) 565 110 mm shoe 566 providing and fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with m.s. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 567 110 mm 568 providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 569 sanitary installations 570 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 571 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 572 providing and fixing white vitreous china pedestal type water closet (european type) with seat and lid, 10 litre low level white vitreous china flushing cistern & c.p. flush bend with fittings & c.i. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 573 w.c. pan with isi marked black solid plastic seat and lid 574 providing and fixing wash basin with c.i. brackets, 15 mm c.p. brass pillar taps, 32 mm c.p. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 575 white vitreous china flat back wash basin size 550x 400 mm with single 15 mm c.p. brass pillar tap 576 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is: 13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 577 kitchen sink with drain board 578 510x1040 mm bowl depth 250 mm 579 extra for using coloured pedestal type w.c pan (european type) with low level cistern of same colour instead of white vitreous china w.c pan and cistern. 580 providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with c.p. brass screws and washers complete. 581 providing and fixing toilet paper holder : 582 vitreous china 583 providing and fixing soil, waste and vent pipes : 584 100 mm dia. 585 centrifugally cast (spun) iron socket & spigot (s&s) pipe as per is: 3989 586 75mm diameter 587 centrifugally cast (spun) iron socketed pipe as per is: 3989 588 providing and fixing m.s. holder bat clamps of approved design to sand cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : 589 for 100 mm dia. pipe 590 for 75 mm dia. pipe 591 providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 592 100 mm 593 sand cast iron s&s as per is 3989 594 75 mm 595 sand cast iron s&s as per is 3989 596 providing and fixing plain bend of required degree. 597 100 mm 598 sand cast iron s&s as per is : 3989 599 75 mm 600 sand cast iron s&s as per is 3989 601 providing and fixing heel rest sanitary bend 602 100 mmdia 603 sand cast iron s&s as per is 3989 604 75 mm dia 605 sand cast iron s&s as per is 3989 606 providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3mm thick,bolts and nuts complete. 607 100x100x100mm 608 sand cast iron s&s as per is 3989 609 75x75x75mm 610 sand cast iron s&s as per is 3989 611 providing and fixing single equal plain junction of required degree 612 100x100x100mm 613 sand cast iron s&s as per is 3989 614 75x75x75mm 615 sand cast iron s&s as per is 3989 616 providing and fixing door piece, insertion rubber washer 3mm thick, bolts & nuts complete : 617 100 mm 618 sand cast iron s&s as per is 3989 619 75 mm 620 sand cast iron s&s as per is 3989 621 providing and fixing terminal guard : 622 100 mm 623 sand cast iron s&s as per is 3989 624 75 mm 625 sand cast iron s&s as per is 3989 626 providing and fixing collar : 627 100 mm 628 sand cast iron s&s as per is 3989 629 75 mm 630 sand cast iron s&s as per is 3989 631 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : 632 100 mm 633 75 mm 634 providing and fixing m.s. stays and clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter : 635 100 mm 636 75 mm 637 providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 638 100 mm inlet and 100 mm outlet 639 sand cast iron s&s as per is: 1729 640 cutting chases in brick masonry walls for following diameter sand cast iron/ centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : 641 100 mm dia 642 painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work : 643 75 mm diameter pipe 644 providing and fixing ptmt waste coupling for wash basin and sink, of approved quality and colour. 645 waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms 646 providing and fixing ptmt bottle trap for wash basin and sink. 647 bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms 648 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 649 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour. 650 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 651 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is: 13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 652 kitchen sink with drain board 653 510x1040 mm bowl depth 250 mm 654 providing and fixing 8mm dia c.p / s.s jet with flexible tube upto1 metre long with s.s triangular plate to eureopean type w.c of quality and make as approved by engineer in charge. 655 providing and fixing g.i. pipes complete with g.i. fittings including trenching & refilling. 656 external work 657 32mmdia nominal bore 658 40mmdia nominal bore 659 water supply 660 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 661 internal work exposed on wall 662 20 mm nominal outer dia pipes 663 25 mm nominal outer dia pipes 664 32 mm nominal outer dia pipes 665 40 mm nominal outer dia pipes 666 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 667 concealed work, including cutting chases and making good the walls etc. 668 15 mm nominal outer dia pipes 669 20 mm nominal outer dia pipes 670 25 mm nominal outer dia pipes 671 32 mm nominal outer dia pipes 672 making connection of g.i. distribution branch with g.i. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 673 25 to 40 mm nominal bore 674 providing and fixing brass stop cock of approved quality : 675 15 mm nominal bore 676 20 mm nominal bore 677 providing and fixing gun metal gate valve with c.i. wheel of approved quality (screwed end) : 678 25mm nominal bore 679 32mm nominal bore 680 40mm nominal bore 681 providing and fixing ball valve (brass) of approved quality, high or low pressure, with plastic floats complete : 682 25 mm nominal bore 683 providing and fixing brass ferrule with c.i. mouth cover including boring and tapping the main : 684 25 mm nominal bore 685 providing and fixing uplasticised pvc connection pipe with brass unions : 686 45 cm length 687 15 mm nominal bore 688 providing and fixing c.p. brass shower rose with 15 or 20 mm inlet : 689 100 mm diameter 690 providing and placing on terrace (at all floor levels) polyethylene water storage tank, is : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 691 rectangular tank 692 providing and fixing c.p. brass bib cock of approved quality conforming to is:8931 : 693 15 mm nominal bore 694 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 695 15 mm nominal bore 696 providing and fixing c.p. brass stop cock (concealed) of standard design and of approved make conforming to is:8931. 697 15 mm nominal bore. 698 providing and fixing c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 699 15 mm nominal bore 700 providing and fixing ptmt grating of approved quality and colour. 701 circular type. 702 100 mm nominal dia. 703 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 704 sewarage & drainage 705 providing, laying and jointing glazed stoneware pipes class sp 1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 706 100 mm diameter 707 150 mm diameter 708 providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all round s.w. pipes including bed concrete as per standard design : 709 100 mm diameter s.w. pipe 710 150 mm diameter s.w. pipe 711 providing and fixing square mouth s.w. gully trap class sp 1 complete with c.i. grating brick masonry chamber with water tight c.i. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70kg as per standard design: 712 180 x 150 mm size p type 713 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 714 constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with r.c.c. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : 715 inside size 90x80 cm and 45 cm deep including c.i. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : 716 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 717 extra for depth for manholes : 718 size 90x80 cm 719 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 720 providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per is : 10910, on 12 mm dia steel bar conforming to is: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 721 making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 722 for pipes 100 to 250 mm diameter 723 providing, laying and jointing non pressure np2 class (light duty)rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 724 150 mm dia rcc pipe 725 250 mm dia rcc pipe 726 non shedule items 727 providing and fixing concealed single leverbath & overhead shower mixer of hindware make and model no.(f360019cp) respectively or equivalent approved make as approved byengineer in charge. 728 providing & fixing sink mixer with swinging casted spout (wall mounted jaquar model con 309 kn)/approved equal with 450mm long copper pipes & brass nuts. 729 providing and fixing c.p. brass grab bar(600mm long) fixed with c.p. brass screwsincluding all fittings complete.jaquar model no. ahs 1507/approve equal. 730 subhead i wiring 731 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. 732 group c 733 wiring for light/ power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 734 wiring for light/ power plug with 4x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 nos. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 735 supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 736 4 module (125 mmx75 mm) 737 supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 738 15/16 a switch 739 3 pin 5/6 a socket outlet 740 telephone socket outlet 741 tv antenna socket outlet 742 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 743 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire 744 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 745 2 x 10 sq. mm + 1 x 6 sq. mm earth wire 746 4 x 4 sq. mm + 2 x 4 sq. mm earth wire 747 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface/ recessed steel/ pvc conduit as required. 748 supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 749 25 mm 750 supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 751 1 or 2 module (75 mmx75 mm) 752 supplying and drawing following pair 0.5 mm dia frls pvc insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ pvc conduit as required. 753 2 pair 754 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 755 20 mm 756 25 mm 757 providing and fixing in position 2mm thick m.s. telephone junction box of size suitable for fixing of following krone tag block with key lock arrangement. also provide clamps for fixing tag blocks. 758 10 pair telephone tag blockwith box 759 supplying, laying of 10 pair unarmoured pvc insulated copper conductor (atc) telephone cable in ground/existing pipes/on wall and making connection with telephone main junction box (mdf) including supports and all accessories as required 760 10 pair cable unarmoured 761 subhead ii supply & installation of fittings 762 supplying of following box type fl. fitting made out of crca sheet finished in antirust treated non yellowing super white stove enamelled paint duly wired with copper wound heavy duty choke starter holder, starter but without lamp complete etc. as reqd. 763 mounting rail for tled lamps 1600 lumens (tmc 501 p 1xt led with essential led 18w tube) 764 sereno 42 watt 2950 lumens philips sp824 p led 30s 5000 gr oa 765 supplying of wall mounted suitable for 1300 lumens complete with ballast & accessories such as wire guard etc. complete as required. 766 15w astra surface & wall mounted 1300 lumens ( philips bn150w led13s 6500 pse od gr ) 767 supplying of wall bracket light fittings suitable for 11 / 13 w cfl lamp. the fitting shall be made up of m.s. powder coated provided with integral ballast, frosted glass and 1 no. 11 / 13 wlamp duly wired upto the connector block complete as required. (decon cat. no.05aam) 768 supplying of ceiling light fittings suitable for 1 x 15/20 w led lamp. the fitting shall be made up of m.s. powder coated provided with electronic ballast, 1 no. 15/20 w led lamp duly wired upto the connector block etc. complete as required. 769 cirrus mini pro 15 / 20 watt & 1100 /1600 lumens (philips sm200c led11s 6500 psu od wh) 770 supplying of bulk head fittings suitable for 10 w led lamp complete with ballast & accessories such as glass, wire guard, 60 w cfl lamp etc. complete as required. 771 endural led bulkhead, 10 w, 600 lumen such as (philips wt202w led6s cw psu s2 pc) 772 supplying of exhaustfan, all complete with mounting ring frame i/c bracket,but without regulator with shutters in the following sizes. (g.e. alsthom, khaitan & havells company) 773 300 mm 4 pole 774 supplying of 1400 mm sweep a.c. electric ceiling fans, capacitor type with double ball bearing complete with 300 mm down rod, canopies, shackles, blades, but without regulator suitable for operation on 230 / 240 volts, 50 hz, single phase, a.c. supply. (crompton, khaitan & havells company) 775 supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 776 installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 777 installation, testing and commissioning of pre wired, light fixture / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 778 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 779 upto 450 mm sweep 780 extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. 781 installation, testing and commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two gls/cfl/ led lamps per fitting, complete with all accessories including connections etc. as required. 782 supplying and fixing call bell/ buzzer suitable for single phase, 230 v, complete as required. 783 subhead iii distribution board 784 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/ isolator) 785 6 way (4 + 18), double door 786 supplying and fixing following rating, four pole, 415 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 787 100 a 788 supplying and fixing following rating, four pole, (three phase and neutral), 415 v, residual current circuit breaker (rccb), having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. 789 63 a 790 supplying and fixing following rating, double pole, 240 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 791 40 amps 792 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 793 12 way , double door 794 16 way , double door 795 supplying and fixing following rating, double pole, (single phase and neutral), 240 v, residual current circuit breaker (rccb), having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. 796 25 a 797 40 a 798 supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 799 single pole 800 subhead iv earthing 801 earthing with g.i. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 802 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re filling as required. 803 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 804 subhead v street lighting on building 805 supplying, installing, testing and commissioning of 2 x 36w general purpose flourescent street light fittings with sheet aluminium housing and uv stabilized acrylic cover complete with chokes, starter holders, condensers, reflector cover etc. as reqd. (philips cat no. trc 33 / 236 hpf) (to be fixed directly on wall of building) 806 supplying and fixing of 32 mm dia x 2.00 meter long g.i. pipe (medium class) bracket for mounting of fluorescent / hpmv / hpsv street light fitting on pole including bending the pipe to the required shape, 2 nos. 40 mm x 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. 807 supply of following sizes of frls 1.1 kv stranded compact circular aluminium conductor screened with extruded semi conducting compound, xlpe insulated,al round wire armoured & overall pvc sheathed cableconforming to is to is 7098 (part i) with latest amendments 808 2 x 4 sq.mm 809 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. 810 upto 35 sq. mm 811 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc/ hume/ metal pipe as required. 812 upto 35 sq. mm 813 laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required. 814 upto 35 sq. mm (clamped with 1mm thick saddle) 815 supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required. 816 2 x 6 sq. mm (19mm) 817 supply & fixing of 150x200 mm 60mm deep ms junction box recess or surface on wall with 3mm bakalite cover15 overlapping 15 all sides of junction box & housing 4way 32amps bakelie connector to terminate incoming & outgoing armoured cable & & wiring the light fixture with 3x1.5 sq mm pvc insulated coppwer wire including interconnection ets as reqired .( cost of termination of armoured cable with gland is not to be included as the same is payable under separate item no 5.07 of this subhead) 818 providing, laying and fixing following dia rcc pipe np2 class (light duty) in ground complete with rcc collars, jointing withcement mortar1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required. 819 100 mm dia 820 subhead vi lightning conductor 821 providing and fixing of lightning conductor finial, made of 25mm dia 300 mm long, g.i. tube, having single prong at top, with85 mm dia 6 mm thick g.i. base plate including holes etc.complete as required. 822 jointing copper / g.i. tape (with another copper/ g i tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 823 fixing of copper/ g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for horizontal run) 824 fixing of copper/ g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for vertical run) 825 providing and fixing testing joint, made of 20 mm x 3 mm thickg.i. strip, 125 mm long, with 4 nos. of g.i. bolts, nuts, chucknuts and spring washers etc. complete as required. 826 laying copper/ g.i. tape 32 mm x 6 mm from earth electrodedirectly in ground as required 827 earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 828 all kinds of soil 829 excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 830 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 831 supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 832 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone iii) : 10 graded stone aggregate 40 mm nominal size) 833 providing and laying in position machine batched and machine mixed design mix m 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per is: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of engineer in charge.“(note : cement content considered in this item is @ 330 kg/cum.“excess/ less cement used as per design mix is payable/recoverable separately). 834 upto plinth level 835 (i) r.c.c. work in footing 836 (ii) r.c.c. work in beam 837 (iii) r.c.c. work in columns 838 above plinth to floor v lvl 839 same as above but r.c.c. work abive plinth lvl. 840 (i) r.c.c. work in lintel 841 (ii) r.c.c. work in beam 842 (iii) r.c.c. work in columns 843 (iv) r.c.c. work in slab 844 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. thermo mechanically treated bars of grade fe 500d or more. 845 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. thermo mechanically treated bars of grade fe 500 d or more. 846 add for plaster drip course/ groove in plastered surface or moulding tor.c.c. projections. 847 centering and shuttering including strutting, propping etc. and removal of form for all heights : 848 foundations, footings, bases of columns, etc. for mass concrete. 849 suspended floors, roofs, landings, balconies and access platform. 850 lintels, beams, plinth beams, girders, bressumers and cantilevers. 851 columns,pillars, piers, abutments, posts and struts. 852 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in foundation and plinth in: 853 cement mortar 1:6 (1 cement : 6 coarse sand) 854 providing and laying damp proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone iii): 4 graded stone aggregate 12.5mm nominal size) 855 providing & applying a coat of residual petroleum bitumen of grade of vg 10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 856 providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick aac blocks in super structure above plinth level up to floor v level with rcc band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of engineer in charge. (the payment of rcc band and reinforcement shall be made for seperately). 857 half brick masonry with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in foundations and plinth in : cement mortar 1:4 (1 cement : 4 coarse sand) 858 extra for providing and placing in position 2 nos 6mm dia. m.s. bars at every third course of half brick masonry. 859 providing and laying in situ seven course water proofing treatment with app (atactic poly propylene) modified polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to is : 702, 3rd and 5th layers of roofing membrane app modified polymeric membrane 1.5 mm thick of 2.25 kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron hmhdpe film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron hmhdpe film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately). 860 providing and laying brick tiles over mumty roofs, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat: 12.19.1 with common burnt clay f.p.s. (non modular) brick tilesof class designation 10 861 providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to is : 14616 and tads 15:2001 (part b), including isi marked m.s. pressed butt hinges bright finished of required size with necessary screws, all complete as per directions of engineerin charge and panelling with panels of : 12 mm thick one side pre laminated particle board (decorative lamination on one side and other sides balancing lamination) grade 1, medium density flat pressed, three layer particle board fpt i or graded wood particle board fpt 1 conforming to is : 3087 bonded with bwp type synthetic resin adhesive as per is : 848 and pre laminated conforming to is : 12823, grade 1, type ii marked : 862 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 863 providing and fixing t iron frames for doors, windows and ventilators of mild steel tee sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer 864 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 865 providing and fixing factory made upvc white colour fixed glazed windows/ ventilators comprising of upvc multi chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to upvc profile), ,upvc extruded glazing beads of appropriate dimension, epdm gasket, g.i fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of engineer in charge. (single / double glass panes and silicon sealant shall be paid separately). variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 866 fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. 867 providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes. 868 providing and fixing wire gauge shutters using galvanized m.s. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 869 30 mm thick shutters with isi marked m.s. pressed butt hinges bright finished of required size second class teak wood 870 providing and fixing factory made upvc white colour sliding glazed window upto 1.50 m in height dimension comprising of upvc multi chambered frame with in built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to upvc profile), appropriate dimension of upvc extruded glazing beads and upvc extruded interlocks, epdm gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), g.i fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of engineer in charge. (single / double glass panes, wire mesh and silicon sealent shall be paid separately). variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 871 three track three panels sliding window with fly proof s.s wire mesh (two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (area of window above 1.75 sqm). 872 15 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement: 6 coarse sand) 873 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) 874 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 875 providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. size of tile 600x600 mm. 876 providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. size of tile 600x600 mm 877 providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. area of slab upto 0.50 sqm 878 providing and laying ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 879 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 880 providing edge moulding to 18mm thick marble stone counters, vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer in charge. 881 granite work 882 extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete. 883 extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/granite/stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 884 steel painting: 885 (a) with ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works. 886 (b) painting withsynthetic enamel paint of approvedbrandand manufactureto give an even shade:two or more coats on new work. 887 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : new work (two or more coats) over and including water thinnable priming coat with cement primer. 888 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade. new work (two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). 889 providing and fixing isi marked oxidised m.s. single acting spring hingeswith necessary screws etc. complete : 890 150 mm 891 providing and fixing oxidised m.s. hasp and staple (safety type)conforming to is : 363 with necessary screws etc. complete : 892 90 mm 893 providing and fixing special quality bright finished brass cupboard orward robe locks with four levers of approved quality including necessaryscrews etc. complete. 894 75 mm 895 providing and fixing wooden moulded corner beading of triangular shape to the junction of panelling etc. with iron screws, plugs and priming coat on unexposed surface etc. complete 2nd class teak wood. 896 50x50 mm (base and height) 897 providing and fixing aluminium sliding door bolts, isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 898 250x16 mm 899 providing and fixing aluminium tower bolts, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 900 200x10 mm 901 providing and fixing aluminium handles, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 902 125 mm 903 providing and fixing aluminium hanging floor door stopper isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. twin rubber stopper 904 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 905 25 mm thick (for cupboard) including isi marked nickel plated bright finished m.s. piano hinges with necessary screws 906 providing and fixing pre laminated flat pressed 3 layer (medium density) particle board or graded wood particle board is : 3087 marked, with one side decorative and other side balancing lamination grade i, type ii exterior grade is : 12823 marked, in shelves with screws and fittings wherever required, edges to be painted with polyurethane primer (fittings to be paid separately). 907 float glass panes 4.0 mm thick glass panes (weight not less than 10 kg/sqm). 908 providing and fixing white vitreous china pedestal type water closet (european type w.c. pan) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. 909 w.c. pan with isi marked white solid plastic seat and lid 910 providingandfixing p.v.c. waste pipe forsink or wash basin including pvc waste fittings complete. 911 flexible pipe 912 40 mm dia(for sink and urinal) 913 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is: 13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 914 kitchen sink with drain board 915 510x1040 mm bowl depth 250 mm 916 providing and fixing wash basin with c.i.brackets, 15 mm c.p. brass pillar taps, 32 mm c.p. brass waste of standard pattern,includingpainting of fittings and brackets, cutting and making good the walls wherever required 917 white vitreous china wash basin size 550x400 mm with single 15 mm c.p. brass pillar tap 918 providing and fixing cp brass 32mm size bottle trap of bapproved quality & make and as per the direction of engineerin charge. 919 providing & fixing c.p. brass health faucet for ablution with 1 meter long pvc tube, hand shower, couplings, wall hook and other accessories. 920 providing & fixing cp brass overhead shower with shower arm, hand shower 95mm dia single lever concealed deusch mixer with provision for connection to overhead shower and easy flex tube with accessories complete i allrespect 921 providing & fixing c.p. brass waste coupling for pvc waste pipe. 922 providing & fixing 600 x 450 mm bevelled edge mirror of superiorglass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with c.p. brass screws and washers complete. 923 providing & fixing toilet paper holder. 924 viterous china 925 providing and fixing of c. p. brass towel rail 600 x 20 mm size complete with c.p. brass brackets 926 providing and fixing of c. p. brass towel ring complete with c.p. brass brackets 927 providing and fixing cp brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 928 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor soil, waste, and vent, type b as per is : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors),reducers, wc connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382. 929 the pipes will be supported with threaded g i rods & u clamps with nuts, washers etc on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg in charge at site. 930 110 mm dia (wall thickness 3.2 to 3.8 mm) 931 75 mm dia (wall thickness 3.2 to 3.8 mm) 932 providing, fixing, jointing and testing in position isi marked (is:4985) upvc pipes of min 6 kg/ sqcm rating with fitting for waste pipe from fixtures to floor trap including reduces, enlarger, socket, couplers, bends, tees etc including fixing at wall/ ceiling level supported by clamp & hangers etc. cutting holes in wall/ floors/ slabs and making good the same with cement concrete 1:2:4 complete as required. 933 32 mm dia. 934 providing & fixing upvc floor trap of self cleansing designwith stainless steel grating complete in all respects. 935 multi floor trap (5 ht) with height raiser and branch saddle strip of 50/75 mm outlet 936 plain floor trap (4 ht) with 50 / 75 outlet and with height raiser 937 p trap type floor trap 110 x 75 mm 938 extra for providing & fixing 125 mm dia c.p. grating in place of c.i. grating over floor traps. 939 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor rain water disposal, type b as peris : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors), reducers, couplers, expansion joints / bellows, cowels, clamps, rubber rings, ms gratings over pipes of bell mouth construction with epoxy painting etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382. 940 the pipes will be supported with threaded g i rods & clamps on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg in charge at site. 941 110 mm dia 942 making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over p.v.c. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 943 providing&fixing15 mm nominal bore45 cm long unplasticised pvc connection pipewith brass unions. 944 45 cm length 945 15 mm nominal bore 946 providing and fixing c.p brass bib cock of approved qualityconforming to is standards is: 8931. 947 15 mm nominal bore 948 providing and fixing c.p brass long nose bib cock of approved qualityconforming to is standardsandweighing notlessthan 810 gms. 949 15 mm nominal bore 950 providing & fixing 15 mm nominal bore c.p brass angle valve for basin mixer and geyser points of approved quality conformingto is8931. 951 15 mm nominal bore 952 constructing brick masonry chamber 300 x 300x500mm, insidewithf.p.s. brick work in cement mortar 1: 4 (1 cement : 4 coarse sand) for stopcock, withc. i. surface box 100 x 100 x 75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4mix (1cement : 2 coarse sand:4 grade stone aggregate 20mm nominal size); necessary excavation, foundationconcrete 1:5:10 (1 cement :5 fine sand: 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar1 : 3 (1 cement : 3 coarse sand )12mmthick finished with a floatingcoatof neat cementcomplete as per standard design 953 with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 954 providing & fixing g.i. unoun in g.i. pipe including cutting and threading the pipe & making long screws etc. complete. 955 15mm dia nominal bore 956 20mm dia nominal bore 957 25mm dia nominal bore 958 32mm dia nominal bore 959 40mm dia nominal bore 960 cutting holes up to 30 x 30 cm in walls including making good the same: 961 with common burnt clay f.p.s. (non modular) bricks 962 providing, fixing chlorinated polyvinyl chloride (cpvc) pipescts sdr 11, class 1 cpvc pipes (pressure rating 28 kg/cm2 at 23oc and 7 kg/cm2 at 82oc) confirming to is : 15778 2007, astm d 2846, havingthermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 963 internal work exposed on wall 964 20mm nominal outer dia pipes 965 25mm nominal outer dia pipes 966 32mm nominal outer dia pipes 967 40mm nominal outer dia pipes 968 providing, fixing chlorinated polyvinyl chloride (cpvc) pipescts sdr 11, class 1 cpvc pipes (pressure rating 28 kg/cm2 at 23oc and 7 kg/cm2 at 82oc) confirming to is : 15778 2007, astm d 2846, havingthermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 969 concealed work including cutting chase and making good the wall etc. 970 15mm nominal outer dia pipes 971 20mm nominal outer dia pipes 972 providing and placing on terrace (at all floor levels) polyethylene water storage tank, is : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 973 circular tank 974 providing & fixing of hand lever operated forged brass body full way ball valve type isolating valve having forged brass hard chrome plated mirror finish ball, steel handle with pvc grip, teflon seat, screwed ends tested to a pressure of 15 kg/sqcm complete. 975 15 mm nominal bore 976 20 mm nominal bore 977 a) 25 mm dia 978 40 mm nominal bore 979 providing & fixing brass ball float valvewith bronzefloats of approved quality complete. 980 20 mm nominal dia 981 providing & fixing of medium class g.i.spout up to 300 mm. length including cutting and making good the walls and floors etc. as required. 982 a) 25 mm dia 983 sub head (i) : internal wiring 984 point wiring in pvc conduit, with modular type switch : 985 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. 986 group c 987 wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed pvc conduit, and earthing the point with 1.5 sq. mm frls pvc insulated copper conductor single core cable etc. as required. 988 group c 989 twin control point wiring in pvc conduit, with modular type switch : 990 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way modular switch, modular switch, suitable m.s. box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. 991 power plug wiring in pvc conduit (2 x 4 sq.mm.) : 992 wiring for light/ power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 993 circuit / sub main wiring in pvc conduit : 994 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 995 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire. 996 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire. 997 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire 998 2 x 10 sq.mm. + 1 x 6 sq.mm. earth wire 999 4 x 10 sq.mm. + 2 x 6 sq.mm. earth wire 1000 s/f light plug point modular type accessories : 1001 supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 a modular socket outlet and 5/6 a modular switch, connections etc. as required 1002 s/f power plug point modular type accessories : 1003 supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 a modular socket outlet and 15/16 a modular switch, connections etc. as required. 1004 supplying and fixing 20 amps, 240 volts, spn, industrial type socket outlet, with 2 poles and earth metal enclosedplug top alongwith 20amps. c curve, sp mcb in sheet steel enclosure, on surface or in recess, with chainedmetal cover for the socket outlet, and complete with connections, testingandcommissioning etc. as required. 1005 s/f modular type electronic fan regulator : 1006 supply and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 1007 s/f modular type blanking plate : 1008 supply and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 1009 sub head (ii) : distribution boards & mcbs 1010 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 1011 8 way , double door 1012 supplying and fixing followingway, horizontal type tp&n, sheet steelmcb distribution board,415 v on surface /recess,completewithtinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (but without mcb / rccb / isolators). 1013 8 way (4 + 24), double door 1014 supplying and fixing following rating, double pole, (single phase and neutral), 240 volts,residual current circuit breaker (rccb), having a sensitivity current upto 30 ma in the existingmcbdbcomplete with connections, testing andcommissioning etc. as required. 1015 63 amps. 1016 supplying and fixing 5 amps. to 32 amps. rating, 240 volts `c series,miniature circuit breaker (mcb)suitable for inductive load offollowingpolesin the existingmcbdbcomplete with connections, testing andcommissioning etc. as required. 1017 single pole 1018 supplying & fixing single pole, blanking plate in the existing mcbdbcomplete etc. as required. 1019 supplying and fixing following rating, single/ double/ three pole, 230/ 415 volts, mcb c curve in the existing mcb db complete with connections, testing and commissioning etc. as required. 1020 63 amps fp mcb 1021 40 amps dp mcb 1022 sub head (iii) : telephone, television & data system 1023 s/f modular boxes, base & cover plate : 1024 supplying and fixing following size / modules, gi box along with modular base & cover plate for modular switches inrecessetc as required 1025 1 or 2 module (75 mm x 75 mm) 1026 s/f modular type switch / socket : 1027 supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc as required 1028 telephone socket outlet 1029 tv antenna socket outlet 1030 supply and fixing offollowingsizes of medium class pvc conduit along with accessories in surface/recess including cuttingthe wall and making good the same in case of recessed conduit as required : 1031 20 mm. 1032 25 mm. 1033 supply and drawing followingpair, 0.5 sq.mm. frls pvc insulated annealed copper conductor, unarmoured telephone cable in the existing surface / recessed steel/ pvc conduit as required. 1034 2 pair 1035 supply and drawing co axial tv cable rg 6 grade, 0.7 mm. solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface / recessed steel/ pvc conduit as required. 1036 sub head (iv) : miscellaneous 1037 providing and fixing m.v. dangernotice plate of 200mmx150mm made of mild steel, atleast 2mm thick and vitreous enamelled white on both sides and with inscription singleredcolouronfrlsontsideas required. 1038 supplying and fixing call bell/buzzer suitablefor single phase, 230 volts, complete as required. 1039 providing and fixing circular/ hexagonal cast iron or m.s. sheet box forceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5mm thick m.s. sheet with its top surface hacked for proper bonding,top lid shall be screwed into the cast iron/ m.s. sheet box by means of3.3 mm dia round headed screws, one lock at the corners. clamp shallbe made of 12 mm dia m.s. bar bent to shape as per standard drawing. 1040 sub head(v): internal lighting fixtures & fans 1041 supply of lighting fixtures 1042 supply of 15w surface mounted led with all accessories as per standard item..(such as panasonic adl04r156 or equivalent). 1043 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 1044 supply of 20w surface mounted led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 1045 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 1046 supply of ceiling & exhaust fans 1047 supply of ac230/250 volts, 50 hzceiling fanwith standarddownrod, blades, 2 nos. caps & regulator etc. isi with 5 star marked & energy efficient complete as required. (such as havells velocity/velocity hs or equivalent). 1048 1200 mm sweep 1049 supply of ac230/250 volts, 50 hz exhaust fansincluding providingnuts, bolts, mounting frlsame and other accessories etc. complete as required (such as ventil air dx white or equivalent). 1050 300 mm sweep 900 rpm 1051 erectionoflightingfixturesandfans 1052 installation, testing and commissioning of pre wired, flourescent fitting / compact fluorescent fitting of all types, complete with all accessories and tubes etc. directly on ceiling / wall, including connection with 1.5 sq. mm. frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 1053 installation, testing and commissioning of ceiling fan including wiring the down rod of standard length (upto 30 cm.) with 1.5 sq. mm. frls pvc insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 1054 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required 1055 upto 450 mm sweep 1056 sub head(vi): lightning conductor 1057 providing and fixing of lightning conductor finial, made of 25mm dia 300 mm long, g.i. tube, having single prong at top, with85 mm dia 6 mm thick g.i. base plate including holes etc.complete as required. 1058 jointing copper / g.i. tape (with another copper/ g i tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 1059 fixing of copper/ g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for horizontal run) 1060 fixing of copper/ g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for vertical run) 1061 providing and fixing testing joint, made of 20 mm x 3 mm thickg.i. strip, 125 mm long, with 4 nos. of g.i. bolts, nuts, chucknuts and spring washers etc. complete as required. 1062 laying copper/ g.i. tape 32 mm x 6 mm from earth electrodedirectly in ground as required 1063 earth work 1064 earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1065 all kinds of soil 1066 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 1067 excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 1068 concrete work 1069 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 1070 1:5:10 (1 cement : 5 coarse sand (zone iii) : 10 graded stone aggregate 40 mm nominal size) 1071 providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : 1072 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). 1073 providing and laying damp proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone iii): 4 graded stone aggregate 12.5mm nominal size) 1074 providing & applying a coat of residual petroleum bitumen of grade of vg 10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 1075 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 1076 reinforcedcementconcrete 1077 centering and shuttering including strutting, propping etc. and removal of form for all heights: 1078 foundations, footings, bases of columns, etc. for mass concrete 1079 columns, pillars, piers, abutments, posts and struts 1080 small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like 1081 edges of slabs and breaks in floors and walls 1082 under 20 cms wide 1083 suspended floors, roofs, landings, balconies and access platform. 1084 lintels, beams, plinth beams, girders, bressumers and cantilevers. 1085 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 1086 thermo mechanically treated bars of grade fe 500d or more. 1087 add for plaster drip course/ groove in plastered surface or moulding to r.c.c. projections. 1088 providing and laying in position machine batched and machine mixed design mix m 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per is: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of engineer in charge.“(note : cement content considered in this item is @ 330 kg/cum.“excess/ less cement used as per design mix is payable/recoverable separately). 1089 all works upto plinth level 1090 all works above plinth level upto floor v level 1091 brick work 1092 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in foundation and plinth in: 1093 cement mortar 1:6 (1 cement : 6 coarse sand) 1094 providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick aac blocks in super structure above plinth level up to floor v level with rcc band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of engineer in charge. (the payment of rcc band and reinforcement shall be made for seperately). 1095 half brick masonry with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level. 1096 cement mortar 1:4 (1 cement :4 coarse sand) 1097 extra for providing and placing in position 2 nos 6mm dia. m.s. bars at every third course of half brick masonry. 1098 brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand). 1099 marble work 1100 providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 1101 granite of any colour and shade 1102 area of slab over 0.50 sqm 1103 providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer in charge. 1104 granite work 1105 extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. 1106 extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 1107 wood work & pvc work 1108 providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). 1109 second class teak wood 1110 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 1111 25 mm thick (for cupboard) including isi marked nickel plated bright finished m.s. piano hinges is : 3818 marked with necessary screws 1112 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1113 35 mm thick including isi marked stainless steel butt hinges with necessary screws 1114 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 1115 providing and fixing wire gauge shutters using galvanized m.s. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 1116 35 mm thick shutters 1117 kiln seasoned and chemically treated hollock wood 1118 providing and fixing aluminium sliding door bolts, isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 1119 250x16 mm 1120 providing and fixing aluminium tower bolts, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 1121 200x10 mm 1122 providing and fixing aluminium handles, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 1123 125 mm 1124 providing and fixing aluminium hanging floor door stopper, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. 1125 twin rubber stopper 1126 providing & fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to is : 2046 type s, including cost of adhesive of approved quality. 1127 1.5 mm thick 1128 providing and fixing cup board shutters with 25 mm thick veneered particle board is : 3097 marked, exterior grade (grade i), of approved make, including iind class teak wood lipping of 25 mm wide x 12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of engineer in charge. 1129 with decorative veneering on one side and commercial veneering on other side 1130 providing and fixing factory made upvc white colour sliding glazed window upto 1.50 m in height dimension comprising of upvc multi chambered frame with in built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to upvc profile), appropriate dimension of upvc extruded glazing beads and upvc extruded interlocks, epdm gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), g.i fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of engineer in charge. (single / double glass panes, wire mesh and silicon sealent shall be paid separately). variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 1131 three track three panels sliding window with fly proof s.s wire mesh (two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (area of window above 1.75 sqm). 1132 providing and fixing isi marked oxidised m.s. single acting spring hingeswith necessary screws etc. complete : 1133 150 mm 1134 providing and fixing oxidised m.s. hasp and staple (safety type)conforming to is : 363 with necessary screws etc. complete : 1135 90 mm 1136 providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 1137 75 mm 1138 providing and fixing wooden moulded corner beading of triangular shape to the junction of panelling etc. with iron screws, plugs and priming coat on unexposed surface etc. complete 2nd class teak wood. 1139 50x50 mm (base and height) 1140 float glass panes 1141 4.0 mm thick glass panes (weight not less than 10 kg/sqm). 1142 steel work 1143 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 1144 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1145 providing and fixing t iron frames for doors, windows and ventilators of mild steel tee sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 1146 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1147 providing and fixing circular/ hexagonal cast iron or m.s. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick m.s. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ m.s. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. clamp shall be made of 12 mm dia m.s. bar bent to shape as per standard drawing. 1148 providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 1149 4.0 mm thick glass panes 1150 flooring 1151 kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 1152 25 mm thick. 1153 providing and fixing glass strips in joints of terrazo/ cement concrete floors. 1154 40 mm wide and 4 mm thick 1155 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 1156 extra for pre finished nosing in treads of steps of kota stone/ sand stone slab. 1157 extra for kota stone/ sand stone in treads of steps and risers using single length up to 1.05 metre. 1158 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 1159 providing and laying ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 1160 providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 1161 size of tile 600x600 mm 1162 providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. 1163 size of tile 600x600 mm 1164 roofing 1165 providing and laying brick tiles over mumty roofs, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat. 1166 with common burnt clay f.p.s. (non modular) brick tilesof class designation 10 1167 making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over p.v.c. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 1168 finishing 1169 12 mm cement plaster of mix 1170 1:6 (1 cement: 6 coarse sand) 1171 15 mm cement plaster on rough side of single or half brick wall of mix: 1172 1:6 (1 cement: 6 coarse sand) 1173 white washing with lime to give an even shade : 1174 new work (three or more coats) 1175 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1176 new work (two or more coats) over and including water thinnable priming coat with cement primer 1177 finishing walls with premium acrylic smooth exterior paint withsilicone additives of required shade: 1178 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 1179 applying priming coat: 1180 with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 1181 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 1182 painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 1183 two or more coats on new work 1184 painting with black anti corrosive bitumastic paint of approved brand and manufacture to give an even shade : 1185 two or more coats on new work 1186 water proofing 1187 providing and laying in situ seven course water proofing treatment with app (atactic poly propylene) modified polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to is : 702, 3rd and 5th layers of roofing membrane app modified polymeric membrane 1.5 mm thick of 2.25 kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron hmhdpe film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron hmhdpe film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately). 1188 providing and laying brick tiles over mumty roofs, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat: 12.19.1 with common burnt clay f.p.s. (non modular) brick tilesof class designation 10 1189 earth work 1190 earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1191 all kinds of soil. 1192 excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 1193 all kinds of soil 1194 pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 1195 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 1196 roofing 1197 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 1198 110 mm diameter 1199 providing and fixing on wall face unplasticised pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 1200 coupler 1201 110 mm 1202 bend 87.5° 1203 110 mm bend 1204 shoe (plain) 1205 110 mm shoe 1206 providing and fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with m.s. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 1207 110 mm 1208 providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 1209 sanitary installations 1210 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1211 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 1212 providing and fixing wash basin with c.i. brackets, 15 mm c.p. brass pillar taps, 32 mm c.p. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 1213 white vitreous china flat back wash basin size 550x 400 mm with single 15 mm c.p. brass pillar tap 1214 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is: 13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 1215 kitchen sink with drain board 1216 510x1040 mm bowl depth 250 mm 1217 extra for using coloured pedestal type w.c pan (european type) with low level cistern of same colour instead of white vitreous china w.c pan and cistern. 1218 providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with c.p. brass screws and washers complete. 1219 providing and fixing toilet paper holder : 1220 vitreous china 1221 providing and fixing soil, waste and vent pipes : 1222 100 mm dia. 1223 centrifugally cast (spun) iron socket & spigot (s&s) pipe as per is: 3989 1224 75mm diameter 1225 centrifugally cast (spun) iron socketed pipe as per is: 3989 1226 providing and fixing m.s. holder bat clamps of approved design to sand cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : 1227 for 100 mm dia. pipe 1228 for 75 mm dia. pipe 1229 providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 1230 100 mm 1231 sand cast iron s&s as per is 3989 1232 75 mm 1233 sand cast iron s&s as per is 3989 1234 providing and fixing plain bend of required degree. 1235 100 mm 1236 sand cast iron s&s as per is : 3989 1237 75 mm 1238 sand cast iron s&s as per is 3989 1239 providing and fixing heel rest sanitary bend 1240 100 mmdia 1241 sand cast iron s&s as per is 3989 1242 75 mm dia 1243 sand cast iron s&s as per is 3989 1244 providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3mm thick,bolts and nuts complete. 1245 100x100x100mm 1246 sand cast iron s&s as per is 3989 1247 75x75x75mm 1248 sand cast iron s&s as per is 3989 1249 providing and fixing single equal plain junction of required degree 1250 100x100x100mm 1251 sand cast iron s&s as per is 3989 1252 75x75x75mm 1253 sand cast iron s&s as per is 3989 1254 providing and fixing door piece, insertion rubber washer 3mm thick, bolts & nuts complete : 1255 100 mm 1256 sand cast iron s&s as per is 3989 1257 75 mm 1258 sand cast iron s&s as per is 3989 1259 providing and fixing terminal guard : 1260 100 mm 1261 sand cast iron s&s as per is 3989 1262 75 mm 1263 sand cast iron s&s as per is 3989 1264 providing and fixing collar : 1265 100 mm 1266 sand cast iron s&s as per is 3989 1267 75 mm 1268 sand cast iron s&s as per is 3989 1269 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : 1270 100 mm 1271 75 mm 1272 providing and fixing m.s. stays and clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter : 1273 100 mm 1274 75 mm 1275 providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 1276 100 mm inlet and 100 mm outlet 1277 sand cast iron s&s as per is: 1729 1278 cutting chases in brick masonry walls for following diameter sand cast iron/ centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : 1279 100 mm dia 1280 painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work : 1281 100 mm diameter pipe 1282 75 mm diameter pipe 1283 providing and fixing ptmt waste coupling for wash basin and sink, of approved quality and colour. 1284 waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms 1285 providing and fixing ptmt bottle trap for wash basin and sink. 1286 bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms 1287 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 1288 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour. 1289 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 1290 providing and fixing g.i. pipes complete with g.i. fittings including trenching & refilling. 1291 external work 1292 32mmdia nominal bore 1293 water supply 1294 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 1295 internal work exposed on wall 1296 25 mm nominal outer dia pipes metre 1297 32 mm nominal outer dia pipes metre 1298 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 1299 concealed work, including cutting chases and making good the walls etc. 1300 15 mm nominal outer dia pipes 1301 20 mm nominal outer dia pipes 1302 making connection of g.i. distribution branch with g.i. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 1303 25 to 40 mm nominal bore 1304 providing and fixing brass stop cock of approved quality : 1305 15 mm nominal bore 1306 20 mm nominal bore 1307 providing and fixing gun metal gate valve with c.i. wheel of approved quality (screwed end) : 1308 25mm nominal bore 1309 32mm nominal bore 1310 40mm nominal bore 1311 providing and fixing ball valve (brass) of approved quality, high or low pressure, with plastic floats complete : 1312 25 mm nominal bore 1313 providing and fixing brass ferrule with c.i. mouth cover including boring and tapping the main : 1314 25 mm nominal bore 1315 providing and fixing uplasticised pvc connection pipe with brass unions : 1316 45 cm length 1317 15 mm nominal bore 1318 providing and fixing c.p. brass shower rose with 15 or 20 mm inlet : 1319 100 mm diameter 1320 providing and placing on terrace (at all floor levels) polyethylene water storage tank, is : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 1321 rectangular tank 1322 providing and fixing c.p. brass bib cock of approved quality conforming to is:8931 : 1323 15 mm nominal bore 1324 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 1325 15 mm nominal bore 1326 providing and fixing c.p. brass stop cock (concealed) of standard design and of approved make conforming to is:8931. 1327 15 mm nominal bore. 1328 providing and fixing c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 1329 15 mm nominal bore 1330 providing and fixing ptmt grating of approved quality and colour. 1331 circular type. 1332 100 mm nominal dia. 1333 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 1334 sewarage & drainage 1335 providing and fixing square mouth s.w. gully trap class sp 1 complete with c.i. grating brick masonry chamber with water tight c.i. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70kg as per standard design: 1336 150 x 100 mm size p type 1337 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 1338 making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 1339 for pipes 100 to 250 mm diameter 1340 providing, laying and jointing non pressure np2 class (light duty)rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 1341 150 mm dia rcc pipe 1342 subhead i wiring 1343 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. 1344 group c 1345 wiring for light/ power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 1346 supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 1347 4 module (125 mmx75 mm) 1348 supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1349 15/16 a switch 1350 3 pin 5/6 a socket outlet 1351 telephone socket outlet 1352 tv antenna socket outlet 1353 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 1354 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire 1355 2 x 10 sq. mm + 1 x 6 sq. mm earth wire 1356 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface/ recessed steel/ pvc conduit as required. 1357 supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 1358 1 or 2 module (75 mmx75 mm) 1359 supplying and drawing following pair 0.5 mm dia frls pvc insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ pvc conduit as required. 1360 2 pair 1361 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1362 20 mm 1363 25 mm 1364 providing and fixing in position 2mm thick m.s. telephone junction box of size suitable for fixing of following krone tag block with key lock arrangement. also provide clamps for fixing tag blocks. 1365 10 pair telephone tag blockwith box 1366 supplying, laying of 10 pair unarmoured pvc insulated copper conductor (atc) telephone cable in ground/existing pipes/on wall and making connection with telephone main junction box (mdf) including supports and all accessories as required 1367 10 pair cable unarmoured 1368 subhead ii supply & installation of fittings 1369 supplying of following box type fl. fitting made out of crca sheet finished in antirust treated non yellowing super white stove enamelled paint duly wired with copper wound heavy duty choke starter holder, starter but without lamp complete etc. as reqd. 1370 mounting rail for tled lamps 1600 lumens (tmc 501 p 1xt led with essential led 18w tube) 1371 supplying of wall bracket light fittings suitable for 11 / 13 w cfl lamp. the fitting shall be made up of m.s. powder coated provided with integral ballast, frosted glass and 1 no. 11 / 13 wlamp duly wired upto the connector block complete as required. (decon cat. no.05aam) 1372 supplying of ceiling light fittings suitable for 1 x 15/20 w led lamp. the fitting shall be made up of m.s. powder coated provided with electronic ballast, 1 no. 15/20 w led lamp duly wired upto the connector block etc. complete as required. 1373 cirrus mini pro 15 / 20 watt & 1100 /1600 lumens (philips sm200c led11s 6500 psu od wh) 1374 supplying of bulk head fittings suitable for 10 w led lamp complete with ballast & accessories such as glass, wire guard, 60 w cfl lamp etc. complete as required. 1375 endural led bulkhead, 10 w, 600 lumen such as (philips wt202w led6s cw psu s2 pc) 1376 supplying of exhaustfan, all complete with mounting ring frame i/c bracket,but without regulator with shutters in the following sizes. (g.e. alsthom, khaitan & havells company) 1377 300 mm 4 pole 1378 supplying of 1400 mm sweep a.c. electric ceiling fans, capacitor type with double ball bearing complete with 300 mm down rod, canopies, shackles, blades, but without regulator suitable for operation on 230 / 240 volts, 50 hz, single phase, a.c. supply. (crompton, khaitan & havells company) 1379 supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 1380 installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 1381 installation, testing and commissioning of pre wired, light fixture / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 1382 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 1383 upto 450 mm sweep 1384 extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. 1385 installation, testing and commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two gls/cfl/ led lamps per fitting, complete with all accessories including connections etc. as required. 1386 supplying and fixing call bell/ buzzer suitable for single phase, 230 v, complete as required. 1387 subhead iii distribution board 1388 supplying, installing, testing and commissioning of compartmentalised cubical type meter board for installation of single phase meter. the cubical board shall be made of 2mm thick c.r.c.a sheet, duly phosphatised powder coated complete with connection bus bar and following accessories mounted in it. 1389 meter board 1390 incoming : 1391 40a tp mccb having breaking capacity 25 ka 1 no. 1392 outgoing : 1393 space for single phase energy meter 4 nos. 1394 25 amp dp mcb 4 nos. 1395 supplying, installing, testing & commissioning of single phase electronic energy meter, tested as per electricity boards requirement. 1396 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 1397 12 way, spn 1398 supplying and fixing following rating, double pole, 240 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 1399 40 amps 1400 supplying and fixing following rating, double pole, (single phase and neutral), 240 v, residual current circuit breaker (rccb), having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. asrequired. 1401 25 amps 1402 supplying of xlpe insulated, pvc sheathed 1.1 kv grade aluminium conductor heavy duty armoured cable as per is : 7098 of size : 1403 4 x 16 sq.mm. 1404 providing, laying and fixing following dia rcc pipe np2 class (light duty) in ground complete with rcc collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required for crossing road/walls 1405 100 mm dia 1406 supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 1407 single pole 1408 subhead iv earthing 1409 earthing with g.i. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 1410 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re filling as required. 1411 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 1412 earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1413 all kinds of soil 1414 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 1415 excavating, supplying and filling of local earth (including royalty)by mechanical transport upto a lead of 5km also includingramming and watering of the earth in layers not exceeding 20cm in trenches, plinth, sides of foundation etc. complete. 1416 concrete work 1417 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 1418 1:5:10 (1 cement : 5 coarse sand (zone iii) : 10 graded stone aggregate 40 mm nominal size) 1419 providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : 1420 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). 1421 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 1422 providing and laying damp proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone iii): 4 graded stone aggregate 12.5mm nominal size) 1423 providing & applying a coat of residual petroleum bitumen of grade of vg 10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 1424 reinforcedcementconcrete 1425 centering and shuttering including strutting, propping etc. and removal of form for all heights: 1426 foundations, footings, bases of columns, etc. for mass concrete 1427 columns, pillars, piers, abutments, posts and struts 1428 small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like 1429 edges of slabs and breaks in floors and walls 1430 under 20 cms wide 1431 suspended floors, roofs, landings, balconies and access platform. 1432 lintels, beams, plinth beams, girders, bressumers and cantilevers. 1433 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 1434 thermo mechanically treated bars of grade fe 500d or more. 1435 add for plaster drip course/ groove in plastered surface or moulding to r.c.c. projections. 1436 providing and laying in position machine batched and machine mixed design mix m 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per is: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of engineer in charge.“(note : cement content considered in this item is @ 330 kg/cum.“excess/ less cement used as per design mix is payable/recoverable separately). 1437 all works upto plinth level 1438 all works above plinth level upto floor v level 1439 brick work 1440 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in foundation and plinth in: 1441 cement mortar 1:6 (1 cement : 6 coarse sand) 1442 providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick aac blocks in super structure above plinth level up to floor v level with rcc band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of engineer in charge. (the payment of rcc band and reinforcement shall be made for seperately). 1443 half brick masonry with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level. 1444 cement mortar 1:4 (1 cement :4 coarse sand) 1445 extra for providing and placing in position 2 nos 6mm dia. m.s. bars at every third course of half brick masonry. 1446 brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand). 1447 marble work 1448 providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 1449 granite of any colour and shade 1450 area of slab over 0.50 sqm 1451 providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer in charge. 1452 granite work 1453 extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. 1454 wood work & pvc work 1455 providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). 1456 second class teak wood 1457 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 1458 25 mm thick (for cupboard) including isi marked nickel plated bright finished m.s. piano hinges is : 3818 marked with necessary screws 1459 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1460 35 mm thick including isi marked stainless steel butt hinges with necessary screws 1461 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 1462 providing and fixing wire gauge shutters using galvanized m.s. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 1463 35 mm thick shutters 1464 kiln seasoned and chemically treated hollock wood 1465 providing and fixing aluminium sliding door bolts, isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 1466 250x16 mm 1467 providing and fixing aluminium tower bolts, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 1468 200x10 mm 1469 providing and fixing aluminium handles, isi marked, anodised (anodiccoating not less than grade ac 10 as per is : 1868) transparent or dyedto required colour or shade, with necessary screws etc. complete : 1470 125 mm 1471 providing and fixing aluminium hanging floor door stopper, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. 1472 twin rubber stopper 1473 providing and fixing pre laminated flat pressed 3 layer (medium density)particle board or graded wood particle board is : 3087 marked, with oneside decorative and other side balancing lamination grade i, type iiexterior grade is : 12823 marked, in shelves with screws and fittingswherever required, edges to be painted with polyurethane primer (fittingsto be paid separately). 1474 18 mm thick 1475 providing and fixing factory made upvc white colour sliding glazed window upto 1.50 m in height dimension comprising of upvc multi chambered frame with in built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to upvc profile), appropriate dimension of upvc extruded glazing beads and upvc extruded interlocks, epdm gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), g.i fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of engineer in charge. (single / double glass panes, wire mesh and silicon sealent shall be paid separately). variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 1476 three track three panels sliding window with fly proof s.s wire mesh (two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (area of window above 1.75 sqm). 1477 providing and fixing isi marked oxidised m.s. single acting spring hingeswith necessary screws etc. complete : 1478 150 mm 1479 providing and fixing oxidised m.s. hasp and staple (safety type)conforming to is : 363 with necessary screws etc. complete : 1480 90 mm 1481 providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 1482 75 mm 1483 providing and fixing wooden moulded corner beading of triangular shape to the junction of panelling etc. with iron screws, plugs and priming coat on unexposed surface etc. complete 2nd class teak wood. 1484 50x50 mm (base and height) 1485 float glass panes 1486 4 mm thick glass pane (weight not less than 10kg/sqm). 1487 steel work 1488 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 1489 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1490 providing and fixing t iron frames for doors, windows and ventilators of mild steel tee sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 1491 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1492 providing and fixing circular/ hexagonal cast iron or m.s. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick m.s. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ m.s. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. clamp shall be made of 12 mm dia m.s. bar bent to shape as per standard drawing. 1493 providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. 1494 m.s. tube 1495 providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 1496 4.0 mm thick glass panes 1497 flooring 1498 providing and fixing glass strips in joints of terrazo/ cement concrete floors. 1499 40 mm wide and 4 mm thick 1500 kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 1501 25 mm thick. 1502 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 1503 extra for pre finished nosing in treads of steps of kota stone/ sand stone slab. 1504 extra for kota stone/ sand stone in treads of steps and risers using single length up to 1.05 metre. 1505 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 1506 providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand),jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 1507 size of tile 600x600 mm 1508 providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. 1509 size of tile 400x400 mm 1510 roofing 1511 providing and laying brick tiles over mumty roofs, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat. 1512 with common burnt clay f.p.s. (non modular) brick tilesof class designation 10 1513 making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over p.v.c. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 1514 finishing 1515 12 mm cement plaster of mix 1516 1:6 (1 cement: 6 coarse sand) 1517 15 mm cement plaster on rough side of single or half brick wall of mix: 1518 1:6 (1 cement: 6 coarse sand) 1519 white washing with lime to give an even shade : 1520 new work (three or more coats) 1521 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1522 new work (two or more coats) over and including water thinnable priming coat with cement primer 1523 finishing walls with premium acrylic smooth exterior paint withsilicone additives of required shade: 1524 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 1525 applying priming coat: 1526 with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 1527 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 1528 painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 1529 two or more coats on new work 1530 water proofing 1531 providing and laying in situ seven course water proofing treatment with app (atactic poly propylene) modified polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to is : 702, 3rd and 5th layers of roofing membrane app modified polymeric membrane 1.5 mm thick of 2.25 kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron hmhdpe film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron hmhdpe film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately). 1532 providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of w.c., kitchen and the like consisting of: 1533 ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to is 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. 1534 iind course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. 1535 iiird course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. 1536 ivth course of 400 micron thick pvc sheet. (overlaps at joints of pvc sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/ sqm). 1537 non shedule items 1538 providing and laying cinder filling in sunken floors and other locationswith approved quality cinder including watering and light ramming etc.required for proper compaction/completion of the work complete in all respects as per drawings and as directed by the engineer in charge. 1539 providing and laying 1st quality ceramic glazed anti skid floortiles of size 300x300 mm (thickness to be specified by the manufacturer) conforming to is:15622 in all colours, shades, sizes as approved over 20 mm thick bed of cement mortar 1: 4 (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc complete in all respects as per specifications/drawings and to the entire satisfaction to the architect. 1540 earth work 1541 earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1542 all kinds of soil. 1543 excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 1544 all kinds of soil 1545 pipes, cables etc, not exceeding 80 mm dia. 1546 pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 1547 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 1548 roofing 1549 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 1550 110 mm diameter 1551 providing and fixing on wall face unplasticised pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 1552 coupler 1553 110 mm 1554 bend 87.5° 1555 110 mm bend 1556 shoe (plain) 1557 110 mm shoe 1558 providing and fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with m.s. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 1559 110 mm 1560 providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 1561 sanitary installations 1562 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1563 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 1564 providing and fixing white vitreous china pedestal type water closet (european type w.c. pan) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. 1565 w.c. pan with isi marked white solid plastic seat and lid 1566 providing and fixing wash basin with c.i. brackets, 15 mm c.p. brass pillar taps, 32 mm c.p. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 1567 white vitreous china flat back wash basin size 550x 400 mm with single 15 mm c.p. brass pillar tap 1568 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is: 13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 1569 kitchen sink with drain board 1570 510x1040 mm bowl depth 250 mm 1571 extra for using coloured pedestal type w.c pan (european type) with low level cistern of same colour instead of white vitreous china w.c pan and cistern. 1572 providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with c.p. brass screws and washers complete. 1573 providing and fixing toilet paper holder : 1574 vitreous china 1575 providing and fixing soil, waste and vent pipes : 1576 100 mm dia. 1577 centrifugally cast (spun) iron socket & spigot (s&s) pipe as per is: 3989 1578 75mm diameter 1579 centrifugally cast (spun) iron socketed pipe as per is: 3989 1580 providing and fixing m.s. holder bat clamps of approved design to sand cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : 1581 for 100 mm dia. pipe 1582 for 75 mm dia. pipe 1583 providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 1584 100 mm 1585 sand cast iron s&s as per is 3989 1586 75 mm 1587 sand cast iron s&s as per is 3989 1588 providing and fixing plain bend of required degree. 1589 100 mm 1590 sand cast iron s&s as per is : 3989 1591 75 mm 1592 sand cast iron s&s as per is 3989 1593 providing and fixing heel rest sanitary bend 1594 100 mmdia 1595 sand cast iron s&s as per is 3989 1596 75 mm dia 1597 sand cast iron s&s as per is 3989 1598 providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3mm thick,bolts and nuts complete. 1599 100x100x100mm 1600 sand cast iron s&s as per is 3989 1601 75x75x75mm 1602 sand cast iron s&s as per is 3989 1603 providing and fixing single equal plain junction of required degree 1604 100x100x100mm 1605 sand cast iron s&s as per is 3989 1606 75x75x75mm 1607 sand cast iron s&s as per is 3989 1608 providing and fixing door piece, insertion rubber washer 3mm thick, bolts & nuts complete : 1609 100 mm 1610 sand cast iron s&s as per is 3989 1611 75 mm 1612 sand cast iron s&s as per is 3989 1613 providing and fixing terminal guard : 1614 100 mm 1615 sand cast iron s&s as per is 3989 1616 75 mm 1617 sand cast iron s&s as per is 3989 1618 providing and fixing collar : 1619 100 mm 1620 sand cast iron s&s as per is 3989 1621 75 mm 1622 sand cast iron s&s as per is 3989 1623 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : 1624 100 mm 1625 75 mm 1626 providing and fixing m.s. stays and clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter : 1627 100 mm 1628 75 mm 1629 providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 1630 100 mm inlet and 100 mm outlet 1631 sand cast iron s&s as per is: 1729 1632 cutting chases in brick masonry walls for following diameter sand cast iron/ centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : 1633 100 mm dia 1634 painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work : 1635 100 mm diameter pipe 1636 75 mm diameter pipe 1637 providing and fixing ptmt waste coupling for wash basin and sink, of approved quality and colour. 1638 waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms 1639 providing and fixing ptmt bottle trap for wash basin and sink. 1640 bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms 1641 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 1642 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour. 1643 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 1644 providing and fixing g.i. pipes complete with g.i. fittings including trenching & refilling. 1645 external work 1646 32mmdia nominal bore 1647 40mmdia nominal bore 1648 50mmdia nominal bore 1649 water supply 1650 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 1651 internal work exposed on wall 1652 25 mm nominal outer dia pipes metre 1653 32 mm nominal outer dia pipes metre 1654 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 1655 concealed work, including cutting chases and making good the walls etc. 1656 15 mm nominal outer dia pipes 1657 20 mm nominal outer dia pipes 1658 making connection of g.i. distribution branch with g.i. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 1659 25 to 40 mm nominal bore 1660 providing and fixing brass stop cock of approved quality : 1661 15 mm nominal bore 1662 20 mm nominal bore 1663 providing and fixing gun metal gate valve with c.i. wheel of approved quality (screwed end) : 1664 25mm nominal bore 1665 32mm nominal bore 1666 40mm nominal bore 1667 providing and fixing ball valve (brass) of approved quality, high or low pressure, with plastic floats complete : 1668 25 mm nominal bore 1669 providing and fixing brass ferrule with c.i. mouth cover including boring and tapping the main : 1670 25 mm nominal bore 1671 providing and fixing uplasticised pvc connection pipe with brass unions : 1672 45 cm length 1673 15 mm nominal bore 1674 providing and fixing c.p. brass shower rose with 15 or 20 mm inlet : 1675 100 mm diameter 1676 providing and placing on terrace (at all floor levels) polyethylene water storage tank, is : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 1677 rectangular tank 1678 providing and fixing c.p. brass bib cock of approved quality conforming to is:8931 : 1679 15 mm nominal bore 1680 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 1681 15 mm nominal bore 1682 providing and fixing c.p. brass stop cock (concealed) of standard design and of approved make conforming to is:8931. 1683 15 mm nominal bore. 1684 providing and fixing c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 1685 15 mm nominal bore 1686 providing and fixing ptmt grating of approved quality and colour. 1687 circular type. 1688 100 mm nominal dia. 1689 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 1690 sewarage & drainage 1691 providing, laying and jointing glazed stoneware pipes class sp 1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 1692 100 mm diameter 1693 150 mm diameter 1694 providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all round s.w. pipes including bed concrete as per standard design : 1695 100 mm diameter s.w. pipe 1696 150 mm diameter s.w. pipe 1697 providing and fixing square mouth s.w. gully trap class sp 1 complete with c.i. grating brick masonry chamber with water tight c.i. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70kg as per standard design: 1698 150 x 100 mm size p type 1699 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 1700 providing, laying and jointing non pressure np2 class (light duty)rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 1701 150 mm dia rcc pipe 1702 subhead i wiring 1703 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. 1704 group c 1705 wiring for light/ power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 1706 supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 1707 4 module (125 mmx75 mm) 1708 supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1709 15/16 a switch 1710 3 pin 5/6 a socket outlet 1711 telephone socket outlet 1712 tv antenna socket outlet 1713 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 1714 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire 1715 2 x 10 sq. mm + 1 x 6 sq. mm earth wire 1716 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface/ recessed steel/ pvc conduit as required. 1717 supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 1718 25 mm 1719 supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 1720 1 or 2 module (75 mmx75 mm) 1721 supplying and drawing following pair 0.5 mm dia frls pvc insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ pvc conduit as required. 1722 2 pair 1723 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1724 20 mm 1725 25 mm 1726 providing and fixing in position 2mm thick m.s. telephone junction box of size suitable for fixing of following krone tag block with key lock arrangement. also provide clamps for fixing tag blocks. 1727 10 pair telephone tag blockwith box 1728 supplying, laying of 10 pair unarmoured pvc insulated copper conductor (atc) telephone cable in ground/existing pipes/on wall and making connection with telephone main junction box (mdf) including supports and all accessories as required 1729 10 pair cable unarmoured 1730 subhead ii supply & installation of fittings 1731 supplying of following box type fl. fitting made out of crca sheet finished in antirust treated non yellowing super white stove enamelled paint duly wired with copper wound heavy duty choke starter holder, starter but without lamp complete etc. as reqd. 1732 mounting rail for tled lamps 1600 lumens (tmc 501 p 1xt led with essential led 18w tube) 1733 supplying of wall bracket light fittings suitable for 11 / 13 w cfl lamp. the fitting shall be made up of m.s. powder coated provided with integral ballast, frosted glass and 1 no. 11 / 13 wlamp duly wired upto the connector block complete as required. (decon cat. no.05aam) 1734 supplying of ceiling light fittings suitable for 1 x 15/20 w led lamp. the fitting shall be made up of m.s. powder coated provided with electronic ballast, 1 no. 15/20 w led lamp duly wired upto the connector block etc. complete as required. 1735 cirrus mini pro 15 / 20 watt & 1100 /1600 lumens (philips sm200c led11s 6500 psu od wh) 1736 supplying of bulk head fittings suitable for 10 w led lamp complete with ballast & accessories such as glass, wire guard, 60 w cfl lamp etc. complete as required. 1737 endural led bulkhead, 10 w, 600 lumen such as (philips wt202w led6s cw psu s2 pc) 1738 supplying of exhaustfan, all complete with mounting ring frame i/c bracket,but without regulator with shutters in the following sizes. (g.e. alsthom, khaitan & havells company) 1739 300 mm 4 pole 1740 supplying of 1400 mm sweep a.c. electric ceiling fans, capacitor type with double ball bearing complete with 300 mm down rod, canopies, shackles, blades, but without regulator suitable for operation on 230 / 240 volts, 50 hz, single phase, a.c. supply. (crompton, khaitan & havells company) 1741 supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 1742 installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 1743 installation, testing and commissioning of pre wired, light fixture / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 1744 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 1745 upto 450 mm sweep 1746 extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. 1747 installation, testing and commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two gls/cfl/ led lamps per fitting, complete with all accessories including connections etc. as required. 1748 supplying and fixing call bell/ buzzer suitable for single phase, 230 v, complete as required. 1749 subhead iii distribution board 1750 supplying, installing, testing and commissioning of compartmentalised cubical type meter board for installation of single phase meter. the cubical board shall be made of 2mm thick c.r.c.a sheet, duly phosphatised powder coated complete with connection bus bar and following accessories mounted in it. 1751 meter board 1752 incoming : 1753 40a tp mccb having breaking capacity 25 ka 1 no. 1754 outgoing : 1755 space for single phase energy meter 4 nos. 1756 25 amp dp mcb 4 nos. 1757 supplying, installing, testing & commissioning of single phase electronic energy meter, tested as per electricity boards requirement. 1758 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 1759 12 way, spn 1760 supplying and fixing following rating, double pole, 240 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 1761 40 amps 1762 supplying and fixing following rating, double pole, (single phase and neutral), 240 v, residual current circuit breaker (rccb), having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. asrequired. 1763 25 amps 1764 supplying of xlpe insulated, pvc sheathed 1.1 kv grade aluminium conductor heavy duty armoured cable as per is : 7098 of size : 1765 4 x 16 sq.mm. 1766 providing, laying and fixing following dia rcc pipe np2 class (light duty) in ground complete with rcc collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required for crossing road/walls 1767 100 mm dia 1768 supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 1769 single pole 1770 subhead iv earthing 1771 earthing with g.i. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 1772 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re filling as required. 1773 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 1774 subhead v lightning conductor 1775 providing and fixing of lightning conductor finial, made of 25mm dia 300 mm long, g.i. tube, having single prong at top, with85 mm dia 6 mm thick g.i. base plate including holes etc.complete as required. 1776 jointing copper / g.i. tape (with another copper/ g i tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 1777 fixing of copper/ g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for horizontal run) 1778 fixing of copper/ g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for vertical run) 1779 providing and fixing testing joint, made of 20 mm x 3 mm thickg.i. strip, 125 mm long, with 4 nos. of g.i. bolts, nuts, chucknuts and spring washers etc. complete as required. 1780 laying copper/ g.i. tape 32 mm x 6 mm from earth electrodedirectly in ground as required 1781 earth work 1782 earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1783 all kinds of soil 1784 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 1785 excavating, supplying and filling of local earth (including royalty)by mechanical transport upto a lead of 5km also includingramming and watering of the earth in layers not exceeding 20cm in trenches, plinth, sides of foundation etc. complete. 1786 concrete work 1787 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 1788 1:5:10 (1 cement : 5 coarse sand (zone iii) : 10 graded stone aggregate 40 mm nominal size) 1789 providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : 1790 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). 1791 providing and laying damp proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone iii): 4 graded stone aggregate 12.5mm nominal size) 1792 providing & applying a coat of residual petroleum bitumen of grade of vg 10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 1793 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 1794 reinforcedcementconcrete 1795 centering and shuttering including strutting, propping etc. and removal of form for all heights: 1796 foundations, footings, bases of columns, etc. for mass concrete 1797 walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc 1798 columns, pillars, piers, abutments, posts and struts 1799 small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like 1800 edges of slabs and breaks in floors and walls 1801 under 20 cms wide 1802 suspended floors, roofs, landings, balconies and access platform. 1803 lintels, beams, plinth beams, girders, bressumers and cantilevers. 1804 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 1805 thermo mechanically treated bars of grade fe 500d or more. 1806 add for plaster drip course/ groove in plastered surface or moulding to r.c.c. projections. 1807 providing and laying in position machine batched and machine mixed design mix m 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per is: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of engineer in charge.“(note : cement content considered in this item is @ 330 kg/cum.“excess/ less cement used as per design mix is payable/recoverable separately). 1808 all works upto plinth level 1809 all works above plinth level upto floor v level 1810 brick work 1811 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in foundation and plinth in: 1812 cement mortar 1:6 (1 cement : 6 coarse sand) 1813 providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick aac blocks in super structure above plinth level up to floor v level with rcc band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of engineer in charge. (the payment of rcc band and reinforcement shall be made for seperately). 1814 half brick masonry with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level. 1815 cement mortar 1:4 (1 cement :4 coarse sand) 1816 extra for providing and placing in position 2 nos 6mm dia. m.s. bars at every third course of half brick masonry. 1817 brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand). 1818 marble work 1819 providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 1820 granite of any colour and shade 1821 area of slab over 0.50 sqm 1822 providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer in charge. 1823 granite work 1824 extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. 1825 wood work & pvc work 1826 providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). 1827 second class teak wood 1828 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 1829 25 mm thick (for cupboard) including isi marked nickel plated bright finished m.s. piano hinges is : 3818 marked with necessary screws 1830 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1831 35 mm thick including isi marked stainless steel butt hinges with necessary screws 1832 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 1833 providing and fixing wire gauge shutters using galvanized m.s. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 1834 35 mm thick shutters 1835 kiln seasoned and chemically treated hollock wood 1836 providing and fixing aluminium sliding door bolts, isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 1837 250x16 mm 1838 providing and fixing aluminium tower bolts, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 1839 200x10 mm 1840 providing and fixing aluminium handles, isi marked, anodised (anodiccoating not less than grade ac 10 as per is : 1868) transparent or dyedto required colour or shade, with necessary screws etc. complete : 1841 125 mm 1842 providing and fixing aluminium hanging floor door stopper, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. 1843 twin rubber stopper 1844 providing and fixing pre laminated flat pressed 3 layer (medium density)particle board or graded wood particle board is : 3087 marked, with oneside decorative and other side balancing lamination grade i, type iiexterior grade is : 12823 marked, in shelves with screws and fittingswherever required, edges to be painted with polyurethane primer (fittingsto be paid separately). 1845 18 mm thick 1846 providing and fixing factory made upvc white colour sliding glazed window upto 1.50 m in height dimension comprising of upvc multi chambered frame with in built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to upvc profile), appropriate dimension of upvc extruded glazing beads and upvc extruded interlocks, epdm gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), g.i fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of engineer in charge. (single / double glass panes, wire mesh and silicon sealent shall be paid separately). variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 1847 three track three panels sliding window with fly proof s.s wire mesh (two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (area of window above 1.75 sqm). 1848 providing and fixing isi marked oxidised m.s. single acting spring hingeswith necessary screws etc. complete : 1849 150 mm 1850 providing and fixing oxidised m.s. hasp and staple (safety type)conforming to is : 363 with necessary screws etc. complete : 1851 90 mm 1852 providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 1853 75 mm 1854 providing and fixing wooden moulded corner beading of triangular shape to the junction of panelling etc. with iron screws, plugs and priming coat on unexposed surface etc. complete 2nd class teak wood. 1855 50x50 mm (base and height) 1856 float glass panes 1857 4 mm thick glass pane (weight not less than 10kg/sqm). 1858 steel work 1859 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 1860 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1861 providing and fixing t iron frames for doors, windows and ventilators of mild steel tee sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 1862 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1863 providing and fixing circular/ hexagonal cast iron or m.s. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick m.s. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ m.s. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. clamp shall be made of 12 mm dia m.s. bar bent to shape as per standard drawing. 1864 providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. 1865 m.s. tube 1866 providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 1867 4.0 mm thick glass panes 1868 flooring 1869 providing and fixing glass strips in joints of terrazo/ cement concrete floors. 1870 40 mm wide and 4 mm thick 1871 kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 1872 25 mm thick. 1873 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 1874 extra for pre finished nosing in treads of steps of kota stone/ sand stone slab. 1875 extra for kota stone/ sand stone in treads of steps and risers using single length up to 1.05 metre. 1876 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 1877 providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand),jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 1878 size of tile 600x600 mm 1879 providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. 1880 size of tile 400x400 mm 1881 roofing 1882 providing and laying brick tiles over mumty roofs, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat. 1883 with common burnt clay f.p.s. (non modular) brick tilesof class designation 10 1884 making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over p.v.c. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 1885 finishing 1886 12 mm cement plaster of mix 1887 1:6 (1 cement: 6 coarse sand) 1888 15 mm cement plaster on rough side of single or half brick wall of mix: 1889 1:6 (1 cement: 6 coarse sand) 1890 white washing with lime to give an even shade : 1891 new work (three or more coats) 1892 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1893 new work (two or more coats) over and including water thinnable priming coat with cement primer 1894 finishing walls with premium acrylic smooth exterior paint withsilicone additives of required shade: 1895 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 1896 applying priming coat: 1897 with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 1898 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 1899 painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 1900 two or more coats on new work 1901 water proofing 1902 providing and laying in situ seven course water proofing treatment with app (atactic poly propylene) modified polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to is : 702, 3rd and 5th layers of roofing membrane app modified polymeric membrane 1.5 mm thick of 2.25 kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron hmhdpe film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron hmhdpe film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately). 1903 applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to is. 2645 and approved by engineer in charge over the rcc slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. 1904 laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to is : 2645 and approved by engineerin charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to is : 2645 and approved by engineerin charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. 1905 after two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to is : 2645 and approved by engineer in charge. 1906 finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to is : 2645 and approved by engineer in charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. 1907 the whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“all above operations to be done in order and as directed and specified by the engineer in charge : 1908 the 1909 providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of w.c., kitchen and the like consisting of: 1910 ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to is 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. 1911 iind course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. 1912 iiird course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. 1913 ivth course of 400 micron thick pvc sheet. (overlaps at joints of pvc sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/ sqm). 1914 non shedule items 1915 providing and laying cinder filling in sunken floors and other locationswith approved quality cinder including watering and light ramming etc.required for proper compaction/completion of the work complete in all respects as per drawings and as directed by the engineer in charge. 1916 providing and laying 1st quality ceramic glazed anti skid floortiles of size 300x300 mm (thickness to be specified by the manufacturer) conforming to is:15622 in all colours, shades, sizes as approved over 20 mm thick bed of cement mortar 1: 4 (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc complete in all respects as per specifications/drawings and to the entire satisfaction to the architect. 1917 earth work 1918 earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1919 all kinds of soil. 1920 excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 1921 all kinds of soil 1922 pipes, cables etc, not exceeding 80 mm dia. 1923 pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 1924 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 1925 roofing 1926 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 1927 110 mm diameter 1928 providing and fixing on wall face unplasticised pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 1929 coupler 1930 110 mm 1931 bend 87.5° 1932 110 mm bend 1933 shoe (plain) 1934 110 mm shoe 1935 providing and fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with m.s. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 1936 110 mm 1937 providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 1938 sanitary installations 1939 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1940 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 1941 providing and fixing white vitreous china pedestal type water closet (european type w.c. pan) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. 1942 w.c. pan with isi marked white solid plastic seat and lid 1943 providing and fixing wash basin with c.i. brackets, 15 mm c.p. brass pillar taps, 32 mm c.p. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 1944 white vitreous china flat back wash basin size 550x 400 mm with single 15 mm c.p. brass pillar tap 1945 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is: 13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 1946 kitchen sink with drain board 1947 510x1040 mm bowl depth 250 mm 1948 extra for using coloured pedestal type w.c pan (european type) with low level cistern of same colour instead of white vitreous china w.c pan and cistern. 1949 providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with c.p. brass screws and washers complete. 1950 providing and fixing toilet paper holder : 1951 vitreous china 1952 providing and fixing soil, waste and vent pipes : 1953 100 mm dia. 1954 centrifugally cast (spun) iron socket & spigot (s&s) pipe as per is: 3989 1955 75mm diameter 1956 centrifugally cast (spun) iron socketed pipe as per is: 3989 1957 providing and fixing m.s. holder bat clamps of approved design to sand cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : 1958 for 100 mm dia. pipe 1959 for 75 mm dia. pipe 1960 providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 1961 100 mm 1962 sand cast iron s&s as per is 3989 1963 75 mm 1964 sand cast iron s&s as per is 3989 1965 providing and fixing plain bend of required degree. 1966 100 mm 1967 sand cast iron s&s as per is : 3989 1968 75 mm 1969 sand cast iron s&s as per is 3989 1970 providing and fixing heel rest sanitary bend 1971 100 mmdia 1972 sand cast iron s&s as per is 3989 1973 75 mm dia 1974 sand cast iron s&s as per is 3989 1975 providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3mm thick,bolts and nuts complete. 1976 100x100x100mm 1977 sand cast iron s&s as per is 3989 1978 75x75x75mm 1979 sand cast iron s&s as per is 3989 1980 providing and fixing single equal plain junction of required degree 1981 100x100x100mm 1982 sand cast iron s&s as per is 3989 1983 75x75x75mm 1984 sand cast iron s&s as per is 3989 1985 providing and fixing door piece, insertion rubber washer 3mm thick, bolts & nuts complete : 1986 100 mm 1987 sand cast iron s&s as per is 3989 1988 75 mm 1989 sand cast iron s&s as per is 3989 1990 providing and fixing terminal guard : 1991 100 mm 1992 sand cast iron s&s as per is 3989 1993 75 mm 1994 sand cast iron s&s as per is 3989 1995 providing and fixing collar : 1996 100 mm 1997 sand cast iron s&s as per is 3989 1998 75 mm 1999 sand cast iron s&s as per is 3989 2000 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : 2001 100 mm 2002 75 mm 2003 providing and fixing m.s. stays and clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter : 2004 100 mm 2005 75 mm 2006 providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 2007 100 mm inlet and 100 mm outlet 2008 sand cast iron s&s as per is: 1729 2009 cutting chases in brick masonry walls for following diameter sand cast iron/ centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : 2010 100 mm dia 2011 painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work : 2012 100 mm diameter pipe 2013 75 mm diameter pipe 2014 providing and fixing ptmt waste coupling for wash basin and sink, of approved quality and colour. 2015 waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms 2016 providing and fixing ptmt bottle trap for wash basin and sink. 2017 bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms 2018 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 2019 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour. 2020 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 2021 providing and fixing g.i. pipes complete with g.i. fittings including trenching & refilling. 2022 external work 2023 32mmdia nominal bore 2024 40mmdia nominal bore 2025 50mmdia nominal bore 2026 water supply 2027 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 2028 internal work exposed on wall 2029 25 mm nominal outer dia pipes metre 2030 32 mm nominal outer dia pipes metre 2031 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 2032 concealed work, including cutting chases and making good the walls etc. 2033 15 mm nominal outer dia pipes 2034 20 mm nominal outer dia pipes 2035 making connection of g.i. distribution branch with g.i. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 2036 25 to 40 mm nominal bore 2037 providing and fixing brass stop cock of approved quality : 2038 15 mm nominal bore 2039 20 mm nominal bore 2040 providing and fixing gun metal gate valve with c.i. wheel of approved quality (screwed end) : 2041 25mm nominal bore 2042 32mm nominal bore 2043 40mm nominal bore 2044 providing and fixing ball valve (brass) of approved quality, high or low pressure, with plastic floats complete : 2045 25 mm nominal bore 2046 providing and fixing brass ferrule with c.i. mouth cover including boring and tapping the main : 2047 25 mm nominal bore 2048 providing and fixing uplasticised pvc connection pipe with brass unions : 2049 45 cm length 2050 15 mm nominal bore 2051 providing and fixing c.p. brass shower rose with 15 or 20 mm inlet : 2052 100 mm diameter 2053 providing and placing on terrace (at all floor levels) polyethylene water storage tank, is : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 2054 rectangular tank 2055 providing and fixing c.p. brass bib cock of approved quality conforming to is:8931 : 2056 15 mm nominal bore 2057 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 2058 15 mm nominal bore 2059 providing and fixing c.p. brass stop cock (concealed) of standard design and of approved make conforming to is:8931. 2060 15 mm nominal bore. 2061 providing and fixing c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 2062 15 mm nominal bore 2063 providing and fixing ptmt grating of approved quality and colour. 2064 circular type. 2065 100 mm nominal dia. 2066 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 2067 sewarage & drainage 2068 providing, laying and jointing glazed stoneware pipes class sp 1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 2069 100 mm diameter 2070 150 mm diameter 2071 providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all round s.w. pipes including bed concrete as per standard design : 2072 100 mm diameter s.w. pipe 2073 150 mm diameter s.w. pipe 2074 providing and fixing square mouth s.w. gully trap class sp 1 complete with c.i. grating brick masonry chamber with water tight c.i. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70kg as per standard design: 2075 150 x 100 mm size p type 2076 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 2077 providing, laying and jointing non pressure np2 class (light duty)rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 2078 150 mm dia rcc pipe 2079 subhead i wiring 2080 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. 2081 group c 2082 wiring for light/ power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 2083 supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 2084 4 module (125 mmx75 mm) 2085 supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 2086 15/16 a switch 2087 3 pin 5/6 a socket outlet 2088 telephone socket outlet 2089 tv antenna socket outlet 2090 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2091 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire 2092 2 x 10 sq. mm + 1 x 6 sq. mm earth wire 2093 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface/ recessed steel/ pvc conduit as required. 2094 supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 2095 25 mm 2096 supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 2097 1 or 2 module (75 mmx75 mm) 2098 supplying and drawing following pair 0.5 mm dia frls pvc insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ pvc conduit as required. 2099 2 pair 2100 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 2101 20 mm 2102 25 mm 2103 providing and fixing in position 2mm thick m.s. telephone junction box of size suitable for fixing of following krone tag block with key lock arrangement. also provide clamps for fixing tag blocks. 2104 10 pair telephone tag blockwith box 2105 supplying, laying of 10 pair unarmoured pvc insulated copper conductor (atc) telephone cable in ground/existing pipes/on wall and making connection with telephone main junction box (mdf) including supports and all accessories as required 2106 10 pair cable unarmoured 2107 subhead ii supply & installation of fittings 2108 supplying of following box type fl. fitting made out of crca sheet finished in antirust treated non yellowing super white stove enamelled paint duly wired with copper wound heavy duty choke starter holder, starter but without lamp complete etc. as reqd. 2109 mounting rail for tled lamps 1600 lumens (tmc 501 p 1xt led with essential led 18w tube) 2110 supplying of wall bracket light fittings suitable for 11 / 13 w cfl lamp. the fitting shall be made up of m.s. powder coated provided with integral ballast, frosted glass and 1 no. 11 / 13 wlamp duly wired upto the connector block complete as required. (decon cat. no.05aam) 2111 supplying of ceiling light fittings suitable for 1 x 15/20 w led lamp. the fitting shall be made up of m.s. powder coated provided with electronic ballast, 1 no. 15/20 w led lamp duly wired upto the connector block etc. complete as required. 2112 cirrus mini pro 15 / 20 watt & 1100 /1600 lumens (philips sm200c led11s 6500 psu od wh) 2113 supplying of bulk head fittings suitable for 10 w led lamp complete with ballast & accessories such as glass, wire guard, 60 w cfl lamp etc. complete as required. 2114 endural led bulkhead, 10 w, 600 lumen such as (philips wt202w led6s cw psu s2 pc) 2115 supplying of exhaustfan, all complete with mounting ring frame i/c bracket,but without regulator with shutters in the following sizes. (g.e. alsthom, khaitan & havells company) 2116 300 mm 4 pole 2117 supplying of 1400 mm sweep a.c. electric ceiling fans, capacitor type with double ball bearing complete with 300 mm down rod, canopies, shackles, blades, but without regulator suitable for operation on 230 / 240 volts, 50 hz, single phase, a.c. supply. (crompton, khaitan & havells company) 2118 supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 2119 installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 2120 installation, testing and commissioning of pre wired, light fixture / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 2121 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 2122 upto 450 mm sweep 2123 extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. 2124 installation, testing and commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two gls/cfl/ led lamps per fitting, complete with all accessories including connections etc. as required. 2125 supplying and fixing call bell/ buzzer suitable for single phase, 230 v, complete as required. 2126 subhead iii distribution board 2127 supplying, installing, testing and commissioning of compartmentalised cubical type meter board for installation of single phase meter. the cubical board shall be made of 2mm thick c.r.c.a sheet, duly phosphatised powder coated complete with connection bus bar and following accessories mounted in it. 2128 meter board 2129 incoming : 2130 40a tp mccb having breaking capacity 25 ka 1 no. 2131 outgoing : 2132 space for single phase energy meter 4 nos. 2133 25 amp dp mcb 4 nos. 2134 supplying, installing, testing & commissioning of single phase electronic energy meter, tested as per electricity boards requirement. 2135 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 2136 12 way, spn 2137 supplying and fixing following rating, double pole, 240 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 2138 40 amps 2139 supplying and fixing following rating, double pole, (single phase and neutral), 240 v, residual current circuit breaker (rccb), having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. asrequired. 2140 25 amps 2141 supplying of xlpe insulated, pvc sheathed 1.1 kv grade aluminium conductor heavy duty armoured cable as per is : 7098 of size : 2142 4 x 16 sq.mm. 2143 providing, laying and fixing following dia rcc pipe np2 class (light duty) in ground complete with rcc collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required for crossing road/walls 2144 100 mm dia 2145 supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 2146 single pole 2147 subhead iv earthing 2148 earthing with g.i. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 2149 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re filling as required. 2150 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 2151 subhead v lightning conductor 2152 providing and fixing of lightning conductor finial, made of 25mm dia 300 mm long, g.i. tube, having single prong at top, with85 mm dia 6 mm thick g.i. base plate including holes etc.complete as required. 2153 jointing copper / g.i. tape (with another copper/ g i tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 2154 fixing of copper/ g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for horizontal run) 2155 fixing of copper/ g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for vertical run) 2156 providing and fixing testing joint, made of 20 mm x 3 mm thickg.i. strip, 125 mm long, with 4 nos. of g.i. bolts, nuts, chucknuts and spring washers etc. complete as required. 2157 laying copper/ g.i. tape 32 mm x 6 mm from earth electrodedirectly in ground as required 2158 levelling 2159 0.75 boys dormitory 2160 0.25 girls dormitory 2161 guest house 2162 type 3(g+2) 2163 type 3(g+1) 2164 type 4(g) 2165 type 2(g+2) 2166 earth work in excavation by mechanical means (hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. 2167 all kinds of soil 2168 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 2169 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. all work upto plinth level. 2170 1:5:10 (1 cement : 5 coarse sand (zone iii): 10 graded stone aggregate 40 mm nominal size). 2171 c/s for mass concrete 2172 providing and laying 60mm thick faciory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved s;ze, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of engineer in charge. 2173 providing and laying at or near ground level factory made kerb stone of m 25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of engineer in charge (length of finished kerb edging shall be measured for payment). (precast c.c. kerb stone shall be approved by engineer in charge). 2174 excavating trenches upto 1.5 meter depth in all kind ofsoil of required width for pipes. including excavation for sockets and dressing of sides ramming of bottoms including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m or as directed at site by engg in charge. 2175 all kinds of soil 2176 pipes, cables etc, not exceeding 80 mm dia. 2177 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings. this includes jointing of pipes & fittings with one step cpvc solvent cement, trenching, refilling & testing of joints complete as per direction of engineer in charge : external work 2178 external work 2179 25 mm dia nominal bore 2180 for vertical 2181 type 2(g+2) (3x3+5) = 14 meter 2182 type 3(g+2) (3x3+5) = 14 meter 2183 type 3(g+1) (3x2+5) = 11 meter 2184 type iv (3+5) = 8 meter 2185 type guest house (3+5) = 8 meter 2186 32 mm dia nominal bore for horizontal surface 2187 for vertical 2188 boys dormitory (3x3+5)=14 meter 2189 girls dormitory (3x2+5)=11 meter 2190 providing and fixing gun metal non return valve of approved quality (screwed end) : 2191 32 mm nominal bore 2192 horizontal 2193 construction of masonary chamber60x60x75 inside in brickwork cement mortar 1.6 2194 with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 2195 providing and fixing c.i. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (the tail pieces, tapers etc if required will be paid separately) : 2196 50 mm dia 2197 providing and fixing gun metal gate valve with c.i. wheel of approved quality (screwed end) : 2198 25 mm nominal bore 2199 32 mm nominal bore 2200 providing and laying in position cement concreteof specified grade excluding the cost of centering and shuttering (for thrust blocks at bends and junctions of water lines )by 1:2:4 (1 cement : 2 coarse sand : 4 graded stone agg. 20 mm nominal size) 2201 providing and fixing g.i. union in gi pipe including cutting and threading the pipe and making long screws etc. complete(new work) 2202 25 mm nominal bore 2203 32 mm nominal bore 2204 40 mm nominal bore 2205 providing and fixing in position pre cast r.c.c. manhole cover and frame of required shape and approved quality 2206 ld 2.5 2207 rectangular shape 600*450 mm internal dimensions 2208 earth work in excavation by mechanical means (hydraulic excavator) i manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2209 all kinds of soil.0.00 1.50m 2210 extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. 2211 all kinds of soil 2212 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 2213 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 2214 1:5:10 (1 cement : 5 coarse sand (zone iii): 10 graded stone aggregate 40 mm nominal size). 2215 providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement all work up to plinth level: 2216 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) 2217 centering and shuttering including strutting, propping etc. and removal of form for: 2218 foundations, footings, bases of columns, etc. for mass concrete. 2219 walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 2220 suspended floors, roofs, landings, balconies and access platform. 2221 lintels, beams, plinth beams, girders, bressumers and cantilevers. 2222 edges of slabs and breaks in floors and walls. 2223 under 20 cm wide 2224 reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete. 2225 thermo mechanically treated bars. 2226 cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete 2227 40 mm thick with 20 mm nominal size stone aggregate 2228 6 mm cement plaster of mix : 2229 1:3 (1 cement : 3 fine sand) 2230 providing and fixing in position pre cast r.c.c. manhole cover and frame of required shape and approved quality 2231 square shape 450 mm internal dimension 2232 providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per is : 10910 on 12mm dia steel bar conforming to is : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 2233 providing and fixing soil, waste and vent pipes 2234 100 mm dia. 2235 centrifugally cast (spun) iron socketed pipe as per is: 3989. 2236 making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and s.w. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. 2237 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 2238 earth work in excavation by mechanical means (hydraulic excavator) i manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2239 all kinds of soil.0.00 1.50m 2240 earth work in excavation by mechanical means (hydraulic excavator) i manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2241 all kinds of soil.1.50 3.00m 2242 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 2243 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 2244 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size). 2245 providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing andreinforcement all work up to plinth level : 2246 1:1.5:3 (1 cement : 1.5 coarse sand (zone iii): 3 graded stone aggregate 20 mm nominal size) 2247 centering and shuttering including strutting, propping etc. and removal of form for: 2248 foundations, footings, bases of columns, etc. for mass concrete. 2249 walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 2250 suspended floors, roofs, landings, balconies and access platform. 2251 lintels, beams, plinth beams, girders, bressumers and cantilevers. 2252 edges of slabs and breaks in floors and walls. 2253 under 20 cm wide 2254 reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete. 2255 thermo mechanically treated bars. 2256 cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete 2257 40 mm thick with 20 mm nominal size stone aggregate 2258 6 mm cement plaster of mix : 2259 1:3 (1 cement : 3 fine sand) 2260 providing and fixing in position pre cast r.c.c. manhole cover and frame of required shape and approved quality 2261 m d 10 2262 square shape 450 mm internal dimension 2263 providing and fixing soil, waste and vent pipes 2264 100 mm dia. 2265 centrifugally cast (spun) iron socketed pipe as per is: 3989. 2266 making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and s.w. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. 2267 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 2268 excavating trenches of required width for pipes, cable, etcincluding excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.50m including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. 2269 all kinds of soil 2270 pipes cables etc. exceeding 80 mm dia. but not exceeding 300mm dia. 2271 providing and laying non pressure np2 class (light duty) r.c.c. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 2272 150 mm dia. r.c.c. pipe 2273 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 2274 1:5:10 (1 cement : 5 coarse sand (zone iii): 10 graded stone aggregate 40 mm nominal size). 2275 centering and shuttering including strutting, propping etc. and removal of form for : 2276 foundations, footings, bases of columns, etc. for mass concrete. 2277 constructing brick masonry manholein cement mortar 1 : 4 (1 cement : 4 coarse sand) with rcc top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4gradestone aggregate 20mm nominal size); foundation concrete 1:4:8 mix(1 cement : 4 coarse sand : 8 gradedstoneaggregate40 mm nominalsize) insideplastering 12 mm thickwith cementmortar 1:3 (1cement 3 coarse sand ) finished with a floating coat of neat cement and makingchannels incementconcrete 1:2:4 (1cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finishd with a floating coat ofneatcement completeasper standard design 2278 inside size 90 x 80 cm & 45 cmdeep including ci cover with frame (light duty) 455 x 610mm internal dimensions, total weight of cover & frame to be not lessthan 38 kg (weight of cover 23 kg and weight of frame 15 kg) 2279 with common burnt clay f.p.s.(non modular) bricks of classic designation 7.5 2280 inside size 120 x 90 cm & 90 cmdeep including ci cover with frame (medium duty) 560mm internal diameter, total wt. of cover & frame to be not lessthan 208 kg (wt. of cover 108 kg and wt. of frame 100 kg) 2281 with common burnt clay f.p.s.(non modular) bricks of classic designation 7.5 2282 extra for depth for manholes: 2283 size 90 x 80 cm 2284 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 2285 size 120 x 90 cm 2286 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 2287 providing and fixing square mouths. w. gully trapclass sp 1 complete with c.i. gratingbrickmasonry chamber with water tight ci cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 2288 180 x 150 mm. size p type 2289 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 2290 providing m.s. foot restsorange colour safety footrest 2291 with 20x20 mm square bar 2292 earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2293 all kinds of soil. 2294 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (40% of item no. 1) 2295 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 2296 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 2297 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size). 2298 brick work with f.p.s. bricks of class designation 75 in foundation and plinth in: 2299 cement mortar 1:6 (1 cement : 6 coarse sand) 2300 12 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 2301 1:4 (1 cement: 4 fine sand) 2302 sub feeder panel 2303 incoming 2304 mccb 200a 35ka tpn 2305 indication light 2306 bus bar feeders 2307 200amp alu.bus bar tpn 2308 out going 2309 g/d phase b mccb 125a 35ka tpn 2310 b/d phase b mccb 125a 35ka tpn 2311 type 3 (g+1) mccb 63a 35ka tpn 2312 type 5 mccb 32a 35ka tpn 2313 guest house mccb 32a 35ka tpn 2314 type 3 (g+2) mccb 63a 35ka tpn 2315 type 2 (g+2) mccb 63a 35ka tpn 2316 spare 2317 emergency section 2318 incoming 2319 mcb 125a 63ka tpn 2320 out going 2321 b/d phase b mcb 63a 35ka dp 2322 g/d phase b mcb 63a 35ka dp 2323 type 3 (g+1) mcb 32a 35ka dp 2324 type 5 mcb 32a 35ka dp 2325 guest house mcb 32a 35ka dp 2326 type 3 (g+2) mccb 32a 35ka dp 2327 type 2 (g+1) mccb 32a 35ka dp 2328 type 2 (g) mccb 32a 35ka dp 2329 spare 2330 enclosure 2331 panel body fabricated in 14/16 swg crca sheet , powder coa ted in siemence grey colour complete in all respects universal gland plates. 2332 boys/girls dormitory panel 2333 incoming 2334 100amp mccb tp 35 ka 2335 indication light r,y,b 2336 bus bar feeders 2337 150amp aluminum bus bar tpn 2338 out going 2339 63amp mcb tpn 10ka 2340 63amp mcb tpn 10ka (spare) 2341 emergency section 2342 incoming 2343 63amp mcb dp 10ka 2344 out going 2345 25amp mcb dp 10ka 2346 32amp mcb dp 10ka 2347 enclosure 2348 1050*1450*150 (17 sft) 2349 panel body fabricated in 14/16 swg crca sheet , powder coa ted in siemence grey colour complete in all respects universal gland plates. 2350 vice principal house panel 2351 incoming 2352 63amp mcb tpn 10ka 2353 indication light r,y,b 2354 bus bar feeders 2355 100amp aluminum bus bar tpn 2356 out going 2357 16 32amp mcb 12sp 10ka 2358 32amp mcb dp 10ka 2359 space for 3 phase meter 2360 emergency section 2361 incoming 2362 32amp mcb dp 10ka 2363 16amp mcb dp 10ka 2364 16amp mcb sp 2365 enclosure 2366 650*500*150 (4sft) 2367 panel body fabricated in 14/16 swg crca sheet , powder coa ted in siemence grey colour complete in all respects universal gland plates. 2368 meter panel (type4/type 2 /type3 /guest house) 2369 incoming 2370 mcb 32a 10 ka tpn 2371 indication light r,y,b 2372 bus bar feeders 2373 100amp alu.bus bar tpn 2374 out going 2375 single phase energy meter 2376 mcb 25a dp 2377 emergency section 2378 incoming 2379 mccb 32a dp 2380 out going 2381 16a dp 2382 enclosure 2383 panel body fabricated in 14/16 swg crca sheet , powder coa ted in siemence grey colour complete in all respects universal gland plates. 2384 supply installation, testing and commissioning of external post top lantern with following and complete as required. 2385 6m high (5.0m above ground) 65mm dia gi pole as approved, adopting socket at top for fixture mentioned below, base plate 300x300x6mm and provision for mounting junction box etc. 1 set 2386 erection of pole in cement concrete 400x400x1000mm deep 1:3:6 ratio cement concrete foundation including excavation , refilling, secured with holding clamps, bolts, nuts, alighnment of poles casting etc. including 100 mm thick lean concrete shall be provided at the bottom. 2387 led type 50 watt (street light) light fittings of all types with allaccessories. 2388 suitable size control box with 1 no. incoming and 2 nos. outgoing terminals and 2 nos. tap out terminal with 1 no.5a hrc fuses complet 1 set 2389 suitable number (s) 40mm dia class b gi pipes(s) from above control box to upto 0.5 meter below ground level for power cable entry. 2390 lt cables 2391 supply of following size of 1.1 kv grade multicore aluminium cunductor pvc sheathed armoured cable as per is 1554. 2392 4 core 25 sqmm 2393 4 core 16 sqmm 2394 3.5 core 240 sqmm 2395 3.5 core 95 sqmm 2396 2 core 50 sqmm 2397 2 core 16 sqmm 2398 2 core 10 sqmm 2399 earthingwithgi earth pipe 4.50 meter long 40mm dia including accessories, and providing masonry enclosure with cover plate having lockingarrangement and watering pipe etc.with charcoal or coke and salt complete as required. 2400 earthingwithgi earth plate 600 x 600 x 3mmthickincluding accessories, and providing masonry enclosure with cover plate having lockingarrangement and watering pipe etc.ith watering pipeof 2.7 meter long etc. with charcoal or coke and salt complete as required. (for mltp & dg body) 2401 providing and fixing 25 mm x 5 mm gi strip in 40 mm dia g.i.pipe from earth electrode, including connection with brass nut bolts , spring washer, excavation and refilling etc, as required ( copper gi plate earthing) 2402 providing& layingearth connection from earth electrode with 6 swg dia giwire in 15 mm gi pipe from earth electrode including connection with gi thimbleexcavation and refilling etc as required. ( for gi pipe earthing ofpoles) 2403 providing and fixing 25mm x 5 mm g.i. strips on surface or in recess for connections etc. as required 2404 providing andfixing mvdanger noticeplate of200 mm x 150 mm madeofmild steelatleast 2 mm thickandvitreousenameled white on both sides & with inscription in signalred colour on front side as required.( on 7mts poles & panels) 2405 lt cables laying 2406 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc/ hume/ metal pipe as required. 2407 upto 35 sq. mm 2408 above 35 sq. mm and upto 95 sq. mm 2409 supplying and laying of following size dwc hdpe pipe isi marked along with all accessories like socket, bend, couplers etc. conforming to is 14930, part ii complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 2410 63 mm dia (od 63 mm & id 51 mm nominal) 2411 120 mm dia (od 120 mm & id 103 mm nominal) 2412 supplying and making end termination with brass comperession gland and aluminium lugs for following size of pvc insulated and pvc sheathed/ xlpe aluminium conductor cable of 1.1 kv grade as required 2413 4 core 25 sqmm 2414 4 core 16 sqmm 2415 3.5 core 240 sqmm 2416 3.5 core 95 sqmm 2417 2 core 50 sqmm 2418 2 core 16 sqmm 2419 2 core 10 sqmm 2420 excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 2421 ordinary rock 2422 pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. 2423 providing and laying non pressure np2 class (light duty) r.c.c. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 2424 150 mm dia. r.c.c. pipe ...

Eastern Coal Fields Ltd - Bihar

42006739 repairing/ replacement/ erection of shielding and earth wire at 25 mva, 33 kv/11 6.6 kv substation at s.b. project....

Eastern Coal Fields Ltd - Bihar

40774056 repairing/ replacement/ erection of shielding and earth wire at 25 mva, 33 kv/11 6.6 kv substation at s.b. project....

Airports Authority Of India - Bihar

40680860 tender for miscellaneous unforeseen ss works at jpni airport, patna; 1 supply of following size of 1.1 kv grade xlpe insulated, pvc sheathed, armoured aluminium conductor cable conforming to is: 7098 ( part 1 ) amended upto date etc complete as required. 2 4cx 25 sq.mm 3 3cx 16 sq.mm 4 supply loop in and loop out outdoor type cable junction box made ofhard thermoplastic polycarbonate having suitable for entry & exit 4cx25 / 3.5cx35 sqmm sq.mm cable, size 300mm x 150mm x 170mm ( lxbxh ) , ingress protection ip66, uv resistanc, flame retardant, ik08, glow wire tested at minimum 960 deg.c as per latest iec code, temp range upto 60 deg c, halogen free, self extinguishing etc. and suitable for perimeter light pole installation etc complete as required. 5 supply of 1x25watt led perimeter light fixture, cct 5700k, cool day light with all accessories including matt grey / black powder coated pressure die cast aluminium alloy housing having effective heat sink for heat dissipation, heat resitant toughened tempered glass with gasket and ss clips to ensure ingress protection, leds are provide with secondary lens optics to get optimum optical performance, driver designed with built in surge voltage, open / short circuit protections & external 10 kv surge protection provided for safety and suitable to works 230v, 50 ac hz supply etc and suitable to fixing on 38mm od arm etc. complete as per tender specifications. 6 supply of 1x200w led flood light luminaries, cct 5700k, cool day light with all accessories including matt grey / black powder coated pressure die cast aluminium alloy housing having effective heat sink for heat dissipation, heat resitant toughened tempered glass with gasket and ss clips to ensure ingress protection, leds are provide with secondary lens optics to get optimum optical performance, driver designed with built in surge voltage, open / short circuit protections & external 10 kv surge protection provided for safety, ms mounting bracket fixed on housing for aiming adjustment and suitable to works 230v, 50 ac hz supply etc complete as per tender specifications. 7 supply of1x40w led post top lantern with spun aluminium canopy and made in die cast aluminium housing with decorative clear opal acrylic diffuser for symettric light distribution with ip65 protection etc. suitable to works on 230v, 50hz, ac supply etc. complete as per tender specifications. 8 erection of perimeter light aluminum pole with 2 nos.bracket upto height 2.4 mtr along with tiltable base flange on existing foundation with supply & fixing of grouting ascessories of pole i.e 4nos. 0.5 dia l type steel foundation bolts of designated 2 feet length with nuts, 2 nos. metalic fastnerduring c.c. foundation work i / c alignment, tightening, etc complete as required as directed by eic.job excluding of c.c. foundation work. 9 installation, testing and commissioning of1x 45w led street light fittings with all accessoriesetc. with provision of suitable gi / ms pipe, clamping on wall surface or as per site requirement including connectionswith suitable pvc insulated, copper conductor cable etc. complete as required. 10 installation, testing & commisssioning of led street light fixtures upto 25 watt luminaire with all accessories on the existing bracket of al perimeter light pole including making connection from loop cable junction box to fittings by 3cx1.5 sq.mm. pvc insulated copper conductor flexible cable etc. complete as required. 11 installation, testing & commisssioning of 200w led flood light luminaries with all accessories on the existing ms structure with making suitable arrangement for fixing with nuts bolts or welding / driling including making connection of existing perimterlight loop cable junction box or switch board to fittings by 3cx1.5 sq.mm. pvc insulated copper conductor flexible cable upto 3 mtr etc. complete as required as per direction of eic. 12 installation, testing and commissioning of 1x40w led post top lantern with all accessories and make suitable arrangement to fixing on existing pole or strucure etc. as per site requirement including connections etc. complete as required. 13 installation, testing and commissioning of loop in and loop out thermoplastic / polycarbonate cable junction box size of size 300mm x 150mm x 170mm and secured with proper holding clamps, nuts, bolts on existing aluminium perimeter light pole at suitable height i / c inside the box supply & fixingsuitable 4way x 100a stud type power bakelite connector for termination of 4cx25 sq.mm al cable, earth terminal, 6a, 10 ka, sp mcb ( 1 no. ) mounting on din rail for installation with connection, alignment, tightening etc complete as required. 14 laying of following size hdpe pipe including coupling etc. of pipe in existing trench for the protection of cable etc complete as required as directed by eic. 15 upto 50mm dia. 16 above 50mm dia. and upto 110mm dia. 17 supply and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required. 18 4c x 25 sq.mm ( 28 mm ) 19 3.5c x 35 sq. mm ( 32mm ) 20 3.5c x 50 sq. mm ( 35mm ) 21 3.5c x 70 sq. mm ( 38mm ) 22 3.5c x 185 sq. mm ( 57mm ) 23 supply and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required. 24 4c x 25 sq.mm 25 3.5c x 35 sq. mm 26 3.5c x 50 sq. mm 27 3.5c x 70 sq. mm 28 3.5c x 185 sq. mm 29 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc / hume / metal / hdpe pipe as required. 30 upto 35 sq. mm 31 above 35 sq. mm and upto 95 sq. mm 32 above 95 sq. mm and upto 185 sq. mm 33 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing masonry open duct as required. 34 upto 35 sq. mm 35 above 35 sq. mm and upto 95 sq. mm 36 above 95 sq. mm and upto 185 sq. mm 37 laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required. 38 upto 35 sq. mm ( clamped with 1mm thick saddle ) 39 above 35 sq. mm and upto 95 sq. mm ( clamped with 25x3mm ms flat clamp ) 40 earthing with g.i. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. 41 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re filling as required. 42 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / pipe / cable etc as required. 43 earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. 44 providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required. 45 providing and fixing 25mm x 5mm copper strip in 40mm dia gi pipe from earth electrode inclunding connection with brass nut, bolt, spring, washer excavation and re filling etc as required. 46 providing and laying in position cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) in foundation of perimeter light pole, feeder pillar etc including form, shuttering, finishing work etc complete as required. 47 providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 ( 1 cement: 3 fine sand ) at all levels. 48 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete as required.thermo mechanically treated bars of grade fe 500d or more. 49 excavation for cable trenches / foundation of depth upto 1.2 m in soft soil including refilling of getting out the excavated soil and disposal of surplus excavated soil within a lead of 50 metres as directed by eic. 50 excavation of hard rock for cable trench including cutting the bituminus / concrete surface getting out and disposal of excavated soil as directed by eic. 51 supply of single dome integral led aviation red light comprising of aluminium housing with polycarbonate enclousre / uv stablized arcylic cover, ip65 protection, electronic drive etc. to works on 230v, 50 hz, ac supply etc complete as required. type: bgav 302 led, make: bajaj or equivalent. 52 installation, testing and commissioning of single dome led aviation light fittings with provision of suitable gi / ms pipe with clamping on wall surface or as per site requirementincluding making connection of existingswitch board to fittings by 3cx1.5 sq.mm. pvc insulated copper conductor flexible cable upto 3 mtr etc. complete as required as per direction of eic. 53 supply and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 54 5 / 6 amps switch 55 15 / 16 amp switch 56 3 pin 5 / 6 amp socket outlet 57 6 pin 15 / 16 amp socket outlet 58 supplying and fixing following size / modules, gi box alongwith modular base & cover plate for modular switches in recess etc as required. 59 3 module ( 100mmx75mm ) 60 6 module ( 200mmx75mm ) 61 wiring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class steel conduit complete as required 62 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 63 4 x 4 sq. mm + 2 x 4 sq. mm earth wire 64 supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box / wooden block including connection etc as required. 65 supply and fixing of following size of medium class pvc conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed cinduit as required. 66 25 mm 67 supply of power cable of 1.1kv grade of following sizes copper conductor pvc insulated pvc sheathed un armoured power cable confirming to is:694 with upto date ammendments etc complete as required. 68 3c x 1.5 sqmm 69 3c x 2.5 sqmm 70 laying one number power cable of 1.1 kv grade upto size 3c x 2.5 sqmm in existing hdpe / gi pipe / open masnory duct / tray / open surface / trench / false ceiling / wall surface with suitable metal saddle etc including proper termination etc complete as required. 71 supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required. 72 3.5c x 185 sq. mm 73 painting with aluminium paint of approved brand and manufacture to give an even shade of two or more coats on existing perimeter light pole including 2 nos.bracket upto height 2.0 mtr including pole numbering and black enamel painting to tiltable ms base plate etc complete as required.. 74 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth etc. complete as required. 75 finishing walls with acrylic smooth exterior paint of required shade:new work ( two or more coat applied @ 1.67 ltr / 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm ) 76 demolishing / cutting cement concrete / bitumins surface by manually / mechanical including disposal of material within 50 metres lead as directed. 77 dismantling of existing loop in and loop out metalic cable junction box of perimeter light pole including cable disconnection and handing over to aai store in good condition within airport premises etc. complete as required....

Military Engineer Services - Bihar

40376955 tender for provision of certain minor and revenue works at bihta under age e / m ( af ) of ge ( af ) bihta.; 1 supply, install, fixing and commissioning split type air conditioner with cooling function eer 3.2 of capacity 1.5 tr, five star rated with cordless remote control unit and in built air ioniser, plasma filter for better indoor air quality, five star rated suitable for wall mounted, single phase, 230 / 250 volt ac, with inverter technology and 100% copper coil including breaking necessary hole in wall for fixing indoor and outdoor unit and making good the disturbed surfaces with cement mortar to match with existing finishes after commissioning, making necessary connections unplasticised pvc pipes medium duty 25 mm dia for draining out condensed water all as required including necessary connection complete all as specified and directed.note : ( i ) quoted rates deem to be included cost of drain pipe, copper tubing and 4 sqmm multi standard copper cable ( all 3 mtr length ) , outdoor unit bracket with required fasteners, cutting hole in brick wall etc. ( ii ) installation and commissioning to be done through oem / itsauthorised service centre / agency. 2 s&f sheet metal enclosure with a two pin and earth plug and socket complete with one single pole mcb of 240 volts, 20 amps, c series, 10 ka, complete all as specified and directed. 3 s & f sub main wiring using approved colour coding ( phase red, neutral black, earth green ) complete with two single core frls pvc insulated and unsheathed stranded copper conductor cable 4 sqmm as current carrying conductor and as neutral cable, voltage rating 1100 volt, isi marked drawn in and including concealed pvc conduit isi marked of dia not less than 25 mm and thickness 2 mm with stranded accessories along with one run of frls pvc green colour insulated, unsheathed, stranded copper conductor of size 4 sqmm, complete all as specified and as directed .notes: ( a ) two runs of single core frls pvc cable with one run of earth contunity conductor and conduit shall be measured as one unit. ( b ) cost of cutting chases in wall for concealling conduit and making good to match with existing finish shall be deemed included in the quoted unit rate. 4 supply and fixautomatic copper wound voltage stabilizer for low and high voltage correction equipped with electronic transistorised relay, time relay for two minute suitable for correction on single phase 50 cycles, ac supplyvolt meter indicator and input voltage 180 v to 300 v and stabilized voltage between 220 ±5% of capacity 5 kva, complete all as specified and directed. note : this item shall be fixed with ac catered in respective item of this schedule. 5 excavation in trenches not exc 1.5 m wide and not exc 1.5 m deep for foundation etc or for shafts, column footings or for laying cables etc not exc 10 sqm on plan and getting out in soft / loose soil, complete all as specified and directed. 6 returning, filling in soil including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick complete all as specified and directed. 7 removing excavated materials ( soil ) not exc 50 m distance and depositing where directed at a level not exc 1.5 m above starting point, complete all as specified and directed. 8 supply and laying well burnt old size sub class b bricks as protection to underground cables, laid dry and flat perpendicular to the direction of cable adjoining each other, complete all as specified and directed. 9 m&l fordry andfine river sandfree from sharp materialas incushioning to cablein trenches for cable protectionincludingnecessary punning and consolidation as required, complete all as specified and as directed. ( depth of sand shall be measured after punning ) . 10 supply, laying, jointing and testing of cable xlpe insulated, screened, pvc bedded, galvanised steel strip or wire armoured electric power cable, heavy duty, with aluminium conductor, 1100 volts grade, complete all as specified and directed for thefollowing size of cables: ( a ) cross sectional area 240 sqmm 3½ core 11 ( b ) cross sectional area 50 sqmm 3½ core 12 ( b ) cross sectional area 35 sqmm 3½ core 13 ( b ) cross sectional area 16 sqmm 4 core 14 s&f gi tubing, light grade, with all fittings and laid in trenches / under roads, drains etc, or fixed to poles / walls with fi clamps, nut, bolts etc and making good disturbed surfaces, complete all as specified and directed for the following bore of pipes: ( a ) 40 mm bore 15 ( b ) 50 mm bore 16 ( b ) 15 mm bore 17 m & l for drilling of suitable dia horizontal bore holes suitable for insertion / laying of pipe upto 50 mm of any description below / under road surface, floor etc at site including making good disturbed surface to match with existing strata after laying pipe complete all as specified and directed. 18 supplying, installing, testing & commissioning out door type cubical panel board outer shell made out of3.15 mm thick ms sheet and inner shell made out of 2 mm thick ms sheet and ms angle section 50x50x6 mm mounted on pcc 1:2:4 type b 1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front openable double door system and cable alloy ( each door hinged with body at 3 places with hinges welded to body and door ) lockable / open able by keys having chromium plated 19 mm dia fancy lock, “u” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 volt, 50 hz, tested at factory approved from cpri for 35 mva rupturing capacity at 415 volts factory fabricated having modern fabrication and testing process, complete all as specified and directed and comprising of the following: ( a ) tpn aluminium bus bar 400 amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “f” class insulators not less than 1.0 mtr long. ( b ) incoming mccb200 amps 4 pole 415 volts ac, icu=100%ics, rupturing capacity 25 ka, confirming to is / iec 60947 2 01 no. ( c ) outgoing mccb 100 amps 3 pole 415 volts ac, icu=100%ics, having microprocessor based release for over current, short circuit & earth fault with display and fault discrimination rupturing capacity 25 ka, confirming to is / iec 60947 2 02 nos. ( d ) ditto but mccb 63 amp 1 no. ( e ) mcb tpn32 amps 16 ka 02 nos . ( h ) indicator lamps led type ryb with holder 01 set of three. ( j ) ct coils of suitable ratio 01 set. 19 supply, install, testing and commissioning of out door type cubical feeder pillarbox, tpn of size 600x600x300mm aluminium bus bar 200 amps, outer shell made out of 3.15 mm thick ms sheet inner shell made out of 2.00mm thick ms sheet and ms angle section 40x40x6 mm on pcc 1:2:4 type b 1 platform 60cm above the ground level and 30 cm below the ground level, frame factory fabricated with front and back openable double door system complete suitable for 3 phase 4 wire 415 volt, 50 hz with ip 54. the bus bar shall be provide with sufficient holes for distribution of lt supply to 8 houses single phase and making necessary distributions with the help of thimbles etc, complete all as specified and as directed. 20 m & l for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick, buried directly in ground ( earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised iron strip 25x4 mmas earthing leadby means of bolts, nuts, check nuts, and washers of galvanised iron or steelincluding excavation and earth work, gi pipe medium grade 32 mm bore for protection of gi strip from earth electrodeto test point / machinery / equipment, supplying and laying charcoal dust, common salt, pcc ( 1:2:4 ) type b1 using 20 mm graded crushed stone agregrate chamber andrcc cover 54 cmx54cm x50 mm thick ( 1:2:4 ) type b 1 using 20 mm graded crushed stone aggregates, reinforced with 8 mm dia tmt bars @ 75mm c / c both ways with mild steel handle 12 mm dia, using round bar, pgi funnel with wire mesh, 20 mm dia gi pipe light grade for watering all as shown in electrical plate no 3 of ssr part 1 and testing on completion includingd taking out the oldunserviceable earthing complete all as specified and directed. note cost of gi strip and gi protection pipe up to a distance 7.5 m shall be included in quated rate of above. 21 s & f for 4 pole mccb 63 to 100 amp, 50 hz, 415 v with rupturing capacity 16 ka, ics = 100% of icu, adjustable type, complete all as specified and directed. 22 s&f 40 watt led decorative post top gate light for 360 degree indirect light with ip 65 protection and complete all as directed. 23 m&l for fixing cable junction box lt 3 phase type having ip 66 / 69 weather proof for outdoor installation made of plastic material of size 350x250x138 mm withopaque cover, conical cable gland aluminium lugs, protection class ip 65, 04 nos aluminium bus bar of size 25x4 mm for three phase and neutral including 01 no mcb sp 6 amps for controlling street light and2 nos ms clamp of size 30x5 mm complete with nut, bolt and washers for mounting the junction box on street light pole complete and all as specified and directed by engineer in charge. make sintex product code gsmb 3425 or equivalent make and model as approved by the ge. 24 s&f pvc insulated and pvc sheathed 4.00 sqmm twin core round fr copper conductor industrial cable, 1100 volt grade, conforming to is 694 and making necessary connections from junction box to street light by using suitable size of aluminium thimbles / terminal etc and testing, complete all as specified and as directed. 25 supply and fix gate light controller nature switch of 3 phase 8 kw ( swadeep 66 8kw 3p ) with contactor, incoming mcb & outgoing mcb rating of 32 amps & main load circuit wiring ( copper ) of min size 10 sqmm. the automatic street light control switch using infrared sensor based nature switch for automatic switching of street lights. nature switch operation should be based on natural light lux level. required illuminance level for switching on is =30 lux and for switching off =10 lux.the sensor should also have part night operation facility of minimum 4 hrs to max 12 hrs. the sensor alongwith suitable power contactor ( s ) and incoming and outgoing mcbs should be enclosed in a pole / wall mountable rust proof, electric shock proof, terminate proof and fr grade ip66 protection class 2 enclosure made of thermoplastic polycorbonate and protected against weather influences. the circuit should have provision for manual operation ( i.e. sensor by pass option ) . make of panel consisting of ( i ) nature switch healer ( ii ) contactors bch ( iii ) mcbs hager ( iv ) enclosure hensel, ( v ) circuit wiring polycab. ( vi ) contactor should confirm to iec 60947 4 1 / is 13947 4 1 and mcbs should conform to iec 60898 / is 8828 or another make as approved by the ge. 26 taking down carefully copper / aluminum concealed flame proof point wiring ( light / fan / socket / power ) complete including fittings and fixtures such as switches, ceiling roses, pendents, regulators, sockets, light fittings, sunk box, steel terminal box, laminated sheet with all accessories etc. and making good finish of the disturbed surfaces of walls in line with existing wall etc complete all as specified and as directed. 27 material and labour for 304 grade stainless steel sheet having thickness 3mm for replacing laminated sheet cover wherever required complete with nut, bolt and washers and complete all as directed and specified by engineer in charge. 28 material & labour for fixing spot light bracketmade out of gi pipe light grade 40mm bore approx length not less than 190 cm at a distance of 1 foot from the wall ( for fixing of spot lights ) including new clamps on both ends of the wall, made out of ms flat of size 30x5mm thick including cutting, welding, drilling holes, nut bolts, washer, etc including applying two coats of aluminium paint over one coat of red oxide primer on ms work and complete all asspecified and directed by engineer in charge. 29 s&f led spike light ( spot light ) environmental friendly, new generation, energy saving, decorative type having ip66 protection led spike light using cob led as light source and complete all as directed. make : havells cat part no lycussps15wled730psymbotg or equivalent. 30 m&l for concealed point wiring complete with pvc frls insulated and unsheathed cable 2.5 sqmm ( nominal area ) multi stranded copper conductor single core conforming to is : 694 medium duty concealed stove enamelled steel conduit conformingto is : 9537 ( part 3 ) and isi marked not less than 20 mm dia with concealed in wall pressed steel terminal boxes not less than 1.2 mm thick of required size ( factory made ) including painting terminal boxes inside and outside with two coats of synthetic enamel paint over one coat of red oxide primer and withtop cover 3 mm thick of plastic laminated sheets of required colour complete with all accessoriesand including pvc frls insulated and unsheathed cable 2.5 sqmm ( nominal area ) multi stranded copper conductor single core conforming to is: 694 of green colour as earth wire to common earth and connected to earth dolly drawn in same concealed conduit complete for the following: ( a ) one light / fan / exhaust fan / power socket outlet point controlled by one switch 31 s & f flame proof switch rotary type with termination box in lm 6 / 16a single pole 250 volt all as specified and directed. make shyaam / sudhir or equivalent. 32 supply and fixing stainless steel flexible wire conduit having cross sectional area 30sqmm for enclosing open wire whereever required and complete all as specified and directed by engineer in charge. 33 supply and fixing stainless steel saddle suitable for clamping purpose of above mentioned stainless steel flexible conduit and complete all as specified and directed by engineer in charge. 34 s & f led bollard made up of extruded aluminium with pc diffuser with fitting on gi pipepipe 12 watt with ordering code surya sle bl 12w blk800 or equivalent as approved by the ge, complete all as specified and directed 35 s&f sheet metal enclosure 2 way single door ip 43 with complete including one single pole & neutral mcb 6a 10 ka c series, fixed flush into walls and making good disturbed surfaces, complete all as specified and directed. 36 supplying and fixing 1100 volts grade heavy duty cable pvc insulated aluminium conductor, served with inner sheathing of pvc tape and overall pvc sheathed in service connections 4 sqmm multi stranded, complete all as specified and directed. 37 m&l for conducting of energy audit of complete electrical system of all assets all as specified and directed by engr in charge.notes : ( i ) energy audit company must be registered with bee. ( ii ) the audit must be as per iso 50002:2014. ( iii ) the transformer / vcb / motor / pump set / dg / stabilizer / isolation transformer / cables / oh conductors / lt / ht panels or any other devices / panels / equipment shall be analysed / audited catering all the pump houses and power houses. ( iv ) all the machine / devices / tools / equipment required the rates are included in schedule rates. ( v ) energy audit reports must contain energy consumption / balance and energy efficiency and shall be submitted to ge ( af ) bihta 38 supply and install air conditioner, vertical pack type units indoor / outdoor complete with cordless remote control unit, twin rotary compressor, single phase units 220v 240v, 50 hz of capacity 2.5 tr, with noise supression technology and time temperature display, minimum 3 star rated with all inbuilt and connected accessories provided by company in box, with inverter technology and 100% copper coil, complete all as specified and directed. 39 s & f sub main wiring using approved colour coding ( phase red, neutral black, earth green ) complete with two single core frls pvc insulated and unsheathed stranded copper conductor cable 6 sqmm as current carrying conductor and as neutral cable, voltage rating 1100 volt, isi marked drawn in and including concealed pvc conduit isi marked of dia not less than 25 mm and thickness 2 mm with stranded accessories along with one run of frls pvc green colour insulated, unsheathed, stranded copper conductor of size 6 sqmm, complete all as specified and as directed .notes: ( a ) two runs of single core frls pvc cable with one run of earth contunity conductor and conduit shall be measured as one unit. ( b ) cost of cutting chases in wall for concealling conduit and making good to match with existing finish shall be deemed included in the quoted unit rate. 40 m & l for suction and discharge copper tubing of appropriate dia and thickness suitable for vertical pack type ac of capacity 2.5 tr with black insulating material fixed on it, complete all as specified and directed....

Military Engineer Services - Bihar

40135204 tender for special repair to bldg no p 86 at ota gaya; 1 demolition of cement concrete ( unreinforced ) in ground floors and pavings n exc 15 cm thickness ( below or above ground level ) . 2 demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. 3 taking down cement plaster on brick or stone walls etc, including racking out joints, hacking for key, scrubbing down with water etc. 4 dismantling floor, hearth or wall tilling including cement mortar bedding , removing serviceable tiles to store and rubbish off the premises. 5 taking down chowkat or frame with shutter ( without taking off shutters from the frames ) areaexceeding 1.5 sq mtr but not exceeding 4 sq mtr each 6 taking down chowkhats or frames not exc. 1.5 sq. m each but with shutters ( without taking off shutters from the frames ) . 7 dismantling water tanks of capacity exc 500 & not exc 1000 litres and removing to store. 8 taking up or down 15mm dia bore steel tubing and connections, including cleaning for refixing or removal to store. 9 taking up or down 20mm dia bore steel tubing and connections, including cleaning for refixing or removal to store. 10 dismantling of asbestos cement ( corrugated, semicorrugated, etc. ) sheets in roof coverings complete. 11 dismantling wrought iron or mild steel work of any description not otherwise provided for complete. 12 taking down eaves gutters and rainwater pipes ( any size or pattern ) , including all fittings, heads, shoes, bends, swan necks, etc., including cleaning or refixing or removal to store ( measured overall as fixed along the centre line over fittings and accessories ) 13 m & l for providing 75 mm thick pcc type c 1, 1 : 3 : 6, ( using 40 mm graded aggregate ) as sub base flooringand finishing surfaces even and smooth without using extra cement complete. 14 m & l for providing 50 mm thick pcc type c 2, 1 : 3 : 6, ( using 40 mm graded aggregate ) as inplinth protection and drain bed complete all as specified and directed. 15 m & l for providing precast cement concrete 1:2:4 type b 1 using 20mm graded stone aggregate as in landings, cover slabs ( for man holes etc ) and similar work including necessary formwork and set in cement mortar 1:6complete all as specified and directed. 16 m&l for brick work using sub class b old bricks straightor curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed. 17 m&l for brick work using sub class b old bricks ( except bricks ) straightor curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed. 18 m & l for 10 mm thick rendering in cement mortar 1:6 on fair faces of brick work or concrete surfaces and finishing the surface even and smoth without using extra cement complete all as specified and directed. note : chicken wire mesh be provided to the joints of column and beams during rendering. 19 m & l for rendering 15mm thick in two layerson external surfaces on brick / concrete surfaces in cm 1:4 finished even and smooth without using extra cement with wpc. note : wpc measured and paid separatly andchicken wire mesh be provided to the joints of column and beams during rendering. 20 m & l for rendering 10mm thick internal surfaces on fair faces of brick or concrete surfaces in cement plaster 1:3 as in ceiling and finished even and smooth ( without using extra cement ) complete. 21 supply only liquid water proofing compound ( make : sika latex power ) 22 cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with finishing with cement mortar 1:3. 23 m & l for non skid ceramic coloured tiles 7 to 8 mm thick ( square / rectangular ) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in cm 1:4 complete all as specified and directed. 24 m & l for coloured glazed ceramic tiles in vertical surface 450x300x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10 mm thick screed bed in cm 1:3 complete all as specified and directed. 25 m & l for machine pressed chequered cement concrete tiles 30cm x 30cm x 30mm thick with grey cement and pigment over 20 mm thick screed bed in cement mortar 1:4 complete all as specified and directed. 26 m & l for machine pressed precast concrete interlocking paver block any shape and size confirming to is 15658 2006 of 60 mm thickness, m 35 grade with grey cement and pigment complete all as specified and directed. 27 sand filling under floors for cushioning including watering and consolidation complete all as specified and directed. 28 m & l for 25mm thick cement concrete type b 0, 1:2:4using 12.50mm graded stone aggregate as in levelling course complete all as specified and directed. 29 m & l for providing pcc type b1, 1 : 2 : 4, ( using 20 mm graded aggregate ) as incoping, and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed. 30 s & f rolled mild steel in joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. ( cut to ordinary lengths i.e. within 20mm of the length indicated ) confirming to fe 410 w ( gde e 250 ) quality a complete. 31 s & f pre painted galvatume aluminum zinc coating gi based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 mpa as in roof covering / cladding to wall, fixed with self tapping screws as specified. 32 s & f solid pvc frame of size 50 mm x 47 mm made out of 5 mm single side prelam pvc sheet & edges will be printed to match with prelam sheet rein forced with ms square tube etc. 33 s & f factory made solid panel pvc door shutter 30mm ( style ) consisting of frame made out of m.s tubes for top and bottom rails m.s frame shall be covered with heat moulded plain colour pvc c channel having a pvc sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour pvc sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour pvc sheets to be fitted in the m.s frame welded / sealed to the stiles and rails with suitable pvc sheet beading and joined together with solvent cement, supplying and fixing in the frame 34 s & f powder coated aluminium section for doors, windows, ventilators sliding / openable etc with joining cleat for fixing, locking arrangement, rubber beading, screws, etc including taking down and making the surface good complete all as specified.make : jindal / hindalco / indalco. note : ( i ) glazing and wire mesh shall be measured and paid separetely. ( ii ) item shall be paid as per weight of aluminium section ( iii ) the rate quoted shall be inclusive of the cost of neoprene beading, glazing pin, screws and powder coated fittings such as locking arraangement etc as required, which shall not be measured for arriving the weight ( iv ) the rate shall also be inclusive of complete packing with silicon gel around contacting surfaces of aluminium work, and including matching the existing. 35 s & f framed work such as grills, gratings, etc.. with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to fe.290.gde e 165 complete all as specified and directed. 36 taking down existing aluminium door or window shutter with frame area exceeding 1 sqm and re fixing in same opening after repair / replace the defective jointing cleats / screws and fittings etc all as per specified and directed by engr in charge. 37 s&f 100 mm long stainless steel butt hinges with steel hinge pin etc. 38 s&f 150 mm long aluminium anodised, barrel tower bolts of extruded section and 12 mm dia fixed. 39 s&f 150mm long aluminium anodised handle cast type and fixed d type 40 s&f250mm long aluminium alloy, anodised, sliding door bolt with hasp, staple ( bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixedcomplete all as specified. 41 s&f white colour rotational three layer moulded polyethylene water storage tanks ( cylinderical vertical with closed top ) capacity 1000 ltrhoisted and fixed in position all as specified and directed. make; sintex / rotex / polycon 42 s & f in repair 25mm dia bore ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed. 43 s & f in repair 25mm dia bore cpvc gate valves with handle or wheel head, screwed both ends for pipe and fixed. 44 s & f in repair 20mm dia bore cpvc gate valves with handle or wheel head, screwed both ends for pipe and fixed. 45 supplying and laying of cpvc pipes 25mm outer dia sdr 11 & plain cpvc sdr 11 including all fittings on walls / ceilings or in floors including necessary cutting / chasing of walls and floors complete all as specified and directed. 46 s & f 25mm bore male brass threaded adaptor ( mta / mbta ) or female brass threaded adaptor ( fta / fbta ) complete. 47 supplying and laying of cpvc pipes 20mm outer dia sdr 11 & plain cpvc sdr 11 including all fittings on walls / ceilings or in floors including necessary cutting / chasing of walls and floors complete all as specified and directed. 48 s & f 20mm bore male brass threaded adaptor ( mta / mbta ) or female brass threaded adaptor ( fta / fbta ) complete. 49 s & f 110mm bore pvc ( swr ) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors and connecting with manholes or disposal place. 50 s & f 110mm dia borepvc ( swr ) bends with access door all as specified and as directed. 51 s & f of pvc ( swr ) junction single, ( single t ) 110 mm bore equal or unequal with acess door complete. 52 s & f 110mm bore pvc ( swr ) vent cowl with rubber ring joints, fixed to pipes all as specified. 53 s & f 75mm bore pvc ( swr ) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors and connecting with manholes or disposal place. 54 s & f 75mm dia borepvc ( swr ) bends with access door all as specified and as directed. 55 s & f of pvc ( swr ) junction single, ( single t ) 75 mm bore equal or unequal with acess door complete. 56 s & f as in repair of vitreous china squatting pan, ‘orissa’ pattern, size 580 x 440 mm white, with integral foot rests water closet ( squatt pattern ) complete including provision of lime concrete bedding complete all as specified and as directed make : hindware / parryware / cera 57 s & f in repair 10 litre capacity pvc valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete. 58 s & f in repair vitreous china wash basin, white, flat back of size 550x400mmexcluding taps, waste, chain and plug and porcelain stopper but including brackets, cutting for and pinning in ends of brackets or erecting stand and inclusive of fixing of supply and waste pipe and 32mm dia chromium plated waste fittings with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed. ( make parryware / hindware / jaquar ) 59 s & f pvc connections 15mm size with ptmt nuts of length 600mm complete. 60 s & f in repair 6mm thick looking mirror of 1st quality glass, mounted on 6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete. ( saint gobain / modifloat ) 61 s & f in repair 15 mm dia bore fancy type chromium plated bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed. 62 s & f in repair 15 mm dia bore fancy type chromium plated two way bib taps, cast copper alloy with crutch or butterfly handle screwed down, high pressure, screwed both ends for iron pipe or for unions. 63 s & f in repair 15 mm dia bore fancy type chromium plated stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed. 64 supply & fix in repair brass chromium plated pillar tap swan neck long body fancy typefor wash hand basin for mixing hot and cold water screwed down for iron pipes suitable for 15mm bore pipe complete. 65 s & f in repair brass / chromium plated tubular towel rail, 20mm dia, d type, 60cm long between flanges complete. 66 s & f in repair soap dish, any type, fixed to plugs with chromium plated brass screws complete. 67 s & f in repair 125mm dia stainless steel grating ( double q ) fixed on floor trap / nahani trap in cement mortar 1:6, all as specified and directed. 68 supply & fix in repair brass chromium plated wall mixer ( 2 / 3 hole ) with provision for connection to shower rose for mixing hot and cold water screwed down for iron pipes suitable for 15mm bore pipe complete all as specified and directed. ( make parryware / prayag / hindware ) 69 s & f in repair chromium plated shower rose 15 mm size, 125mm long with 300 mm arms including fixing to pipe or union complete. ( make : jaguar / parryware / hindware ) 70 s & f in repair harrison rails ofbore 20 25mm , mild steel, chromium plated cut to length as required and fixing with brackets, stops, rollers, finiales etc complete all as specified and directed. 71 m & l for 2 mm thick of birlawhite putty / jk white wall care putty in two coats on new / old plastered surfaces and making the surface uniform & smooth on walls / ceilings. 72 m & l for preparing new plastered wall surfaces and distempering two coats on walls with distemper oil emulsion, white or tinted over a coat of chalk whiting complete all as specified and directed. 73 m & l for preparing new plastered ceiling surfaces and distempering two coats on ceilings with distemper oil emulsion, white or tinted over a coat of chalk whiting complete all as specified and directed. 74 m & l for preparation of old plasteredsurfaces and applying one coat of acrylic distemper on walls complete all as specified and as directed. 75 m & l for preparation of old plasteredsurfaces and applying one coat of acrylic distemper in ceilings complete all as specified and as directed. 76 m & l for one coat of exterior emulsion paint white or tinted on walls of fascia of roof or chajjas on old decorated prepared plastered / painted surfaces of bldg all as specified and directed. make : asian paints ( brand ace ) / berger paint ( brand walmasta ) / nerolac paint ( suraksha plus ) . 77 m & l for two coats of exterior emulsion paint white or tinted over a coat of primer on walls of fascia of roof or chajjas on new prepared plastered surfaces of bldg all as specified and directed. make : asian paints ( brand ace ) / berger paint ( brand walmasta ) / nerolac paint ( suraksha plus ) . 78 m & l for one coat of exterior weather proof emulsion paint tinted on walls of fascia of roof or chajjas on old painted surfaces brick, stone, concrete, asbestos cement or plaster on old decorated prepared plastered / painted surfaces of bldg all as specified and directed. make : asian paints ( apex ) / berger paint ( brand weathercoat smooth ) / nerolac paint ( nerolac ) . 79 m & l two coat of syntetic enamel paint overnewsteel surface of any description over 10cm in width or grithnot otherwise describedover one coat red oxide primerincl preparation of surfaces complete. 80 s&f 4mm thick sheet glass, ordinary quality and glazing with oil putty in a square n exc 0.5 sq m in each pane. 81 s & f of 4.00 mm thick figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete. 82 s & fstainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40mm and fixed with beeding / staples complete all as specified and directed. 83 m&l for providing water proofing treatment over cleaned roof surface with super thermo app modified polymeric membrane comprising of followings : ( i ) . complete removal of existing roof treatment by picking, sweeping clean and washing down with water to remove dust etc from plastered / roof surface / walls and filling the crackes with sealing compound grade a . ( ii ) rendering / screed bed 15 mm thick in cement mortor ( 1:4 ) mixed with liquid water proofing compound as per manufacturers instructions andfinished the surface fair and even. ( iii ) applying evenly a coat of bitumen based primer conforming to is 3384 1965 @ 0.30 kg / sqm. ( iv ) applying 3 mm thick app modified polymeric membrane with non polyster reinforcement of approved make, weight not less than 3.50 kg / sqm laid with gas torch and fastedon roof surface with roller. the over laps 100mm and shall be sealed by torch application as per manufacture instructions including vertical surfaces after cutting necessary grooving and making good with pcc 1:2:4 type b o with sika latex power as per manufacture instructions. ( v ) applying two coats of bituminous anticorrosive multi purposealuminium coating ( super silver shield ) @ 150 gm / sqm per coat over polymeric membrene. note : wpc shall be measured and paid separately. 84 m&l for conventional rcc septic tank designed to carry sewage and sullage water, excavation in any type of soil, pcc 1:4:8 below foundation, rcc m 30 design mix in walls, base slab, baffle walls and roof slab including beams etc with vent shaft, manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 50 users. 85 soakage wells exc, in ordinary soil, foundation in pcc 1:3:6 wells of honey combed and solid in m 25 concrete , incl interlocking chamber, screen chamber brick work in cm, rcc cover slab in m 25 / rr masonary / filling with brick bats, complete of size 2.4 dia x 3.00 m deep. 86 taking down copper / aluminium point wiring ( light, fan, bell, socketor power ) complete including fixture and fittings such as switches, ceiling roses, pendent, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit ( credit a for above items should be made as per condition seperately ) and making good distrubed surfaces ofwalls, floors etc complete all as specified and directed at site. 87 taking down old / unserviceable distribution board by disconnection of electric connection carefully spn dbs / tpn dbs / main switch including old unserviceable mccbs / mcbs, isolators, etc and making good to disturbed surface complete all as specified and directed. 88 taking down carefully copper / aluminium sub main wiring of any size fromsurface / concealed / existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed. 89 taking down ceiling fan / exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan bladesand deposit to mes store yard of age e / m complete all as specified and as directed. 90 m&l for point wiring with 1.5 sq mm single core pvc insulated unsheathed copper frls multi stranded conductor cable in andincluding concealed pvc conduit of size 20 / 25mm isi marked inclusive oftees, bend, elbows etc upto and including sunk in anodized pressed steel box for housing switch socket etc withwhite laminated 3 mm thick hylam sheet cover isi marked of suitable size complete including pvc insulated multi strandedcopper conductor 1.5 sq mm frls cable as earth wire to common earth dolly for connection to ceiling rose to earth terminalincludingcutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed by engr in charge for following : 91 ( a ) one light point controlled by one, one way switch 5 amps 92 ( b ) one fan point / exhaust fan point controlled by one, one way switch 5 amps and regulator 93 ( c ) one 3 point 5 amps switch socket outlet point controlled by one switch on the same board. 94 ( d ) one 3 pin 5 amps switch socket outlet point controlled by one switch on independent board. 95 description all as per item no 90 here in before butusing 2.5 sq mm single core copper conductor cable of multistranded flame retardant pvc insulated unsheathed 1100 volts grade for 5 / 15 amps switch socket cobmination point including necessary running of2.5 sq mm copper conductor flame retardant pvc wire as earth continuity conductor along with wiring and connecting to the common eath dolly. 96 s & f switch piano type single pole 5 amp, 230 volts complete all as specified and directed. 97 s & f switch piano type single pole 15 amp, 230 volts complete all as specified and directed. 98 s & f socket outlet 2 in 1, 5 pin, 5 amp, 230 volts complete all as specified and directed. 99 s & f socket outlet 2 in 1, 5 pin, 5 / 15 amp, 230 volts complete all as specified and directed. 100 s & f ceiling rose, surface bakelite with 3 terminals, isimarked for batten fitting complete. 101 s & f stepped type electronic fan regulator flushtype complete all as specified and directed. 102 s & f lamp holder, pvc / polycarbonate type with back plate suitabl for batten / slanting fittings complete all as specified and directed. 103 m & l for sub main wiring with approved colour coding as per is with two single core pvc insulated frls cable with stranded copper conductor of size 6 sq mm nominal area and drawing into suitable size of pvc non metallic rigid heavy duty pvc conduit of white / ivory colour and its accessaries isi marked heavy duty of suitable sizeincluding concealed in wall etcone run of pvc insulated with 6.0 sqmm ( nominal area ) stranded copper conductor frls cable as earth wire complete all as specified and as directed. note: two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of pvc conduit will be measured as one unit 104 s & f for sheet metal enclosure mcb db tpn 4 way vertical type with 200 amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the dbs in wall by cutting the brick / stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. 105 s & f for sheet metal enclosure mcb db spn 8 way with 200 amps rated bus bar 240 volts double door with magnetic locking system including necessary provision for inserting the dbs in wall by cutting the brick / stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. 106 s & f formcb tripple pole and neutral rated capacity 63 amps, 415 volts breaking capacity 10 ka, c curve complete all as specified and as directed. 107 s & f for mcb single pole and neutral rated capacity 32 amps, 240 volts breaking capacity 10 ka, c curve complete all as specified and as directed. 108 s & ffor mcb single pole rated capacity 5 to 32 amps, 240 volts breaking capacity 10 ka, c curve complete all as specified and as directed. 109 s & f for ceiling fan, 230 volts, 1200 mm sweep with service value of the fan shall be greater than 6.1 as per bis with necessary accessories and electrical connections from ceiling rose to fan teriminal complete all as specified and as directed. 110 s & f for highly efficient led bulbs, 10 w, used as a ready replacement for existing gls / cfl direct fit lamp, in b 22 cap of make bajaj, havells, hpl complete all as specified and directed 111 s & f forled 10 watts batten aluminium extruded with decorative end caps complete all as specified and as directed. make bajaj cat part no bclsb 10 nw or its equivallent model in wipro, philips. 112 s & f for wall mounted led tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouputboxtype fitting, 230 volts and intregrated electronic driverconnector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired andnecessary mounting arrangements, provision of new 3 core multistrandedcopper conductor of size 23 / 0.193 from ceiling rose to fitting complete all as specified and as directed. 113 s & f building security lightfitting 1 x 35 / 36 w led new generation energy saving & environmental friendly long life led street / bldg security light made up of pressure die cast aluminium housing with mid power led as lighting source and pc cover having top opening including driver compartment driver with ip66 protection and impact resistance of ik07 including with suitable for 32mm dia medium grade g i bracket not exc 1.5 mtr length made to shape & fixing on pole / wall with 2 nos of ms clamp including necessary connection from lt oh line / buildings 114 s & f for energy efficient exhaust fan of 230 mm sweep made of metal body ventil air ds type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of pvc flexible copper cable of size 23 / 0.0076 two core from ceiling rose to exhaust fan forconnection and making suitable size ofhole to existing brick wall for fan basecompelte all as specifiedand directed. ( note : cost of suitable opening wall for fixing exhaust fan is deemed to be includedin overall rate quoted ) . 115 taking down existing old extg unserviceable lt ug / service cable of any description and sizecomplete all as specified and directed. 116 supply & laying in trenches / laid in floor / duct / drawn through conduitxlpe insulated, armoured, heavy duty elecric cable with alluminium conductor, 1100 volt grade cross sectional area 25 sqmm 4 core. 117 excavation in trenches not exceeding 1.5 mtrs wide & not exceeding 1.5 mtr in depth in soft or loose soil & getting out complete all as per & directed. 118 returning filling including spreading levelling watering & well ramming in layers not exc 25 cm 119 removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as directed. 120 m & l for laying of hdpe double wall corrugated pipes in trench for ug cable protection conforming to is 14930 part ii with ip 67 having outer dia 50 mm and inner dia of 38 mm including necessary fittings such as couplers, bends etc complete all as specified and directed. make: rex / rudrax polymers / finolex 121 m & l for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically ( earth pit not less than 2.25m deep below ground level ) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to gi earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia. medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, pcc chamber, ci frame and cover, ms funnel with wire mesh all as shown in electrical plate no 3 of ssr part i including excavation and earthwork in any type ofsoil / strata and testing on completion. note: gi earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted....

All India Institute Of Medical Sciences - Bihar

39409945 tender for electrical work in old building at residential complex aiims patna; 1 wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface i recessed steel conduit, with modular switch, modular plate, suitable gl box and earthing the point with 1.5 sq. mm frls pvc insulated copper conductor single core cable etc. as required. 2 wiringfortwincontrollightpointwith 1.5sq.mmfrlspvc insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc .as required. 3 rewiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable and 1.5 sq.mm frls pvc insulated copper conductor single core cable as earth wireinexistingsurface / recessedsteel / pvc conduit including dismantling as required.group c 4 wiring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed steel conduit as required2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire 5 wiring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed steel conduit as required 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire 6 wiring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed steel conduit as required 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 7 wiring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed steel conduit as required 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 8 wiring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed steel conduit as required4 x 10 sq. mm + 2 x 6 sq. mm earth wire 9 wiring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed steel conduit as required4 x 16 sq. mm + 2 x 6 sq. mm earth wire 10 supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface / recessed steel / pvc conduit as required. 3 x 1.5 sq. mm 11 supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface / recessed steel / pvc conduit as required. 3x4sq. mm 12 supplying and fixing metal box of following sizes ( nominal size ) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.180 mm x 100 mm x 60 mm 13 supplying and fixing metal box of following sizes ( nominal size ) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 200 mm x 125 mm x 60 mm 14 supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5 / 6 a switch 15 supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15 / 16 a switch 16 supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 10 / 6 a modular socket outlet 17 supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15 / 16 a socket outlet 18 supplyingand fixingtwo module steppedtypeelectronicfan regulatorontheexistingmodularplateswitch boxincluding connections but excluding modular plate etc. as required. 19 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 20 supplying and fixing following size / modules, gl box alongwith modular base & cover plate for modular switches in recess etc. as required.3 module ( 100mmx75mm ) 21 supplying and fixing following size / modules, gl box alongwith modular base & cover plate for modular switches in recess etc. as required.6 module ( 200mmx75mm ) 22 supplying and fixing following size / modules, gl box alongwith modular base & cover plate for modular switches in recess etc. as required. 8 module ( 200mmx75mm ) 23 supplying and fixing 3 pin, 5 a ceiling rose on the existing junction box / wooden block including connections etc. as required. 24 supplying and fixing brass batten / angle holder including connection etc. as required. 25 installation, testingandcommissioningofceilingfan, including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mmfrlspvcinsulated, copperconductor, singlecorecable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 26 numberingofceilingfan / exhaustfan / fluorescentfittingsas required. 27 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.upto 450 mm sweep 28 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcbirccb / isolator ) 6 way, double door 29 supplying and fixing of following ways surface / recess mounting, vertical type, 415 v, tpn mcb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 a tinned copper bus bar, common neutral link, earth bar, din bar for mounting mcbs ( but without mcbs and incomer ) as required.8 way ( 4 + 24 ) , double door 30 supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required.single pole 10 amp 31 supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required.single pole 20 amp 32 supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required.single pole 32 amp 33 supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required.triple pole and neutral ( 32 amp. ) 34 supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required.triple pole and neutral ( 63 amp. ) 35 supplying and fixing followingrating, four pole, ( threephase and neutral ) , 415 volts, residual current circuit breaker ( rccb ) , having a sensitivity current 30ma in the existingmcbdb complete with connections, testing and commissioning etc. as required. 63a 36 supplying and fixing dp sheet steel enclosure on surface / recess along with 25 / 32 a 240 v c curve dp mcb complete with connections, testing and commissioning etc. as required. 37 supplying and fixing 20 amps, 240 volts, spn industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “c” curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 38 supplying and fixing cable end box ( loose wire box ) suitable for following triple pole and neutral, sheet steel, mcb distribution board, 415volts, onsurface / recess, completewithtestingand commissioning etc.as required. for 8 way, double door tpn mcbdb 39 earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. 40 providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required. 41 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. 42 supply, installation, testing and commissioning of 1200 mm sweep, bee 5 star rated, ceiling fan with brush less direct current ( bldc ) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value ( cm / m / w ) minimum 6.00, air delivery minimum 210 cum / min , 350 rpm ( tolerance as per is : 374 2019 ) , thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c ( max. ) , insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. 43 supplying and fixing18 / 20 watt led batten light ( syska / crompton / havells / wipro ) 44 supplying and fixing20 watt led down light ( squre ) ( syska / crompton / havells / wipro ) 45 supplying and fixing 40 / 36 watt led down light ( squre ) ( syska / crompton / havells / wipro ) 46 supplying and fixing 300mm 1350 rpm 1 phase exhaust fan ( havells / crompton ) turbo force 47 supplying and fixing 300w flood light with lense ( syska / crompton / havells / wipro ) 48 supplying and fixing25mm casing &caping...

Department Of Pharmaceuticals - Bihar

39323756 bids are invited for supply and fixing electric connection supply and fixing tpn mcb 4 pole 63 amp , supply and fixing tpn mcb db box with 1 nos 4 pole 63 amp mcb , supply and fixing ups input and output copper flexible wire with 32 mm pvc pipe , supply and fixing ups output db box to power socket copper fixable wire , supply and fixing wiring or circuit wiring alongwith earth wire with the following size of frls pvc insulated copper flexible conductor , misc charge total quantity : 423...

Indian Institute Of Technology - Bihar

39051825 tender for electrical works to provide power to several machine in the department of mme; 1 wiring for light point / fan point / exhaust fan point / call bellpoint with 1.5 sq.mm frls pvc insulated copper conductorsingle core cable in surface / recessed medium class pvcconduit, with modular switch, modular plate, suitable gi boxand earthing the point with 1.5 sq.mm frls pvc insulatedcopper conductor single core cable etc. as required. ( group c ) polycab / rr kabel / kei 2 wiring for circuit / submain wiring alongwith earth wire with the2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire sizes of frls pvc insulated copper conductor, singlecore cable in surface / recessed medium class pvc conduit asrequired. polycab / rr kabel / kei 3 wiring for circuit / submain wiring alongwith earth wire with the 2 x 4 sq. mm + 1 x 4 sq. mm earth wire sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required.polycab / rr kabel / kei 4 wiring for circuit / submain wiring alongwith earth wire with the 4 x 10 sq. mm + 2 x 6 sq. mm earth wire sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required.polycab / rr kabel / kei 5 wiring for circuit / submain wiring alongwith earth wire with the 4 x 6 sq. mm + 2 x 6 sq. mm earth wire sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required.polycab / rr kabel / kei 6 providing and fixing 100 a, 36ka, fp mccb rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.legrand / abb / l&t 7 providing and fixing 200 a, 36ka, fp mccb rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.legrand / abb / l&t 8 supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of single poles in the existing mcb db complete with connections, testing and commissioning etc. as required.legrand / abb / l&t 9 supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of four poles in the existing mcb db complete with connections, testing and commissioning etc. as required.legrand / abb / l&t 10 supplying and fixing 63 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of triple poles in the existing mcb db complete with connections, testing and commissioning etc. as required.legrand / abb / l&t 11 supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5 / 6 a modular socket outlet and 2 nos. 5 / 6 a modular switch, connections etc. as required. ( for light plugs to be used in non residential buildings ) .lrgrand mylink / equivalent 12 supplying and fixing metal sheet enclosure suitable for four pole including connection etc. as required.legrand / abb / l&t 13 supplying and fixing suitable size pvc box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5 / 6 & 15 / 16 amps modular socket outlet and 15 / 16 amps modular switch, connection etc. as required. 14 supplying and making end termination with brass compression gland and aluminium lugs for 3½ x 70 sq. mm ( 38 mm ) size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required....

Department Of Pharmaceuticals - Bihar

37976714 bids are invited for supply and fixing of electrical items wiring of circuit or ups subman wiring along with earth wire with frls pvc insulated copper flexible conductor single core cable with all accessories , supply and fixing 16 way db box fixing and accessories metrial , supply and fixing 4 pole mcb , supply and fixing sp mcb , service charges for fixing total quantity : 64...

Bihar State Power Transmission Company Limited - Bihar

34184241 replacement of single acsr zebra conductor with accc zebra (htls equivalent to zebra) conductor ampacity equivalent to twin moose conductor and stringing of earth—wire in 400kv charged on 220kv) s/c ttps biharsharif t l atongwith repairing of tower peak....

Health And Family Welfare Department - Bihar

30458823 bids are invited for pile boring, providing and installation bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using direct mud circulation ( dmc ) or bailer and chisel technique by tripod and mechanical winch machine all complete, including removal of excavated earth with all its lifts and leads ( length of pile for payment shall be measured up to bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , upvc door providing and fixing of factory made upvc white colour casement door, upvc multichambered extruted frame, sash and mullion profile. frame duly reinforced with 1.2mm gi section box tpe chamber and sash with 1.5mm thick gi section ( ± 0.2mm ) based on wind load calculations ( shape and size according to upvc profiles ) , appropiate dimentions of upvc extruded glazing bead, epdm gasket ( k / o type ) , seperate drainage system, ss34 grade friction hinges 2d / 3d plate hinges, zinc alloy ( white powder coated ) casement handle, gi fastener 8x100 mm size for fixing frame to finish wall, plastic packer and caps and necessary steel screws etc.profile of frame and sash shall be metered cut and fusion welded at all corners, mullion shall be also fusion welded / joined mechanically including drilling of holes for fixing hardware and drainage of water etc. after fixing of frames , gap between frame and adjascent wall shall be filled with pu foaam / backer rod required size and the approved quantity. after that sealed with weather proof silicon sealant at both side, all complete as per approved drawing and direction of eic , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 1 providing and laying vitrified floor tiles in different sizes ( thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including grouting the joints with white cement and matching pigments etc., complete. size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge :flamed finish granite stone slab jet black, cherry red, elitebrown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item ( galvanised@80gsm ) 50 mm long 8mmouter diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’ , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975. the wind load shall be as per provisions of is 875 ( part iii ) . lgsfs frame shall be designed as per is: 801 using commercially available software such as frame cad pro 11.7 / staad pro v8i / architekv2.5.16 / revit architecture 2011 or equivalent. proper usage of connection accessories like heavy duty tension ties, light duty hold ons, twist straps ( to connect truss with wall frames ) , strong tie, tie rod, h brackets, boxing sections, l shaped angles for better structural stability. the framing section shall be cold form c type having minimum web depth 89 mm x 39mm flange x 11mm lip in required length as per structural design requirement duly punched with dimple / slot at required locations as per approved drawings. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm and. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , face panel providing and fixing in all exterior face panels breathable vapour barrier underneath the cementfiber board as per national building code 2009 complete as per direction of engineer in charge. , lap siding supplying and installation of moisture resistant / fire resistantlap siding 8 mm thick and width as per standard sizes made ofiber cement board with embossed decorative finish to give pleasing exterior fixed horizontally with staggered joints including minimum over lapof 32 mm external cement fibre boardconforming to is 14862:2000 offixed with self drilling / taping screws / fastners of approved make. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1 new work ( two or more coats ) over and including water tinnable priming coat with cement primer , ex. paint finishing walls with textured exterior paint of required shade : new work ( two or more coats applied @ 3.28 ltr / 10 sqm ) over and including priming coat of exterior primer applied @ 2.20kg / 10 sqm sqm , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel 1 steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , road providing and laying c.c. pavement of mix m 25 with ready mixed concrete from batching plant. the ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc.complete as per specifications and directions of engineer in charge. ( the panel shuttering work shall be paid for separately ) . ( note: cement content considered in this item is @ 330 kg / cum. excess / less cement used as per design mix is payable / recoverableseparately ) . , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 1 providing & fixing stone slab table rubbed, edges rounded and polished of size 75 x 50cm deep and 1.8 cm thick fixed in urinal patitions by cutting chase of appropriate width with chase cutter and embedding the stone in chase with epoxy grout or with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregste 6mm nominal size ) as per engineer in charge and finished smooth white agaria marble stone , phe 2 providing and fixing salem stainless steel a isi 304 ( 18 / 8 ) kitchen sink as per is: 13983 with ci brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required. kitchen sink with drain board510x1040mm bowl depth 200mm. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing:rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixturescomplete, including cutting and making good the walls andlevel whitep.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings andfloors wherever required :white vitreous china orissa pattern w.c. pan of size580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 9 providing and fixing cp brass 32mm size bottle trap of approved quality & make and as per the direction of engineer in charge.. ( sink & urinal ) , phe 10 providing & fixingptmt towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealedfittings arrangement of approved quality and colour weighing not less than 88 gms , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size 660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 15 providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water ( 250 ml & 500 ml consumption ) , having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of engineer in charge.. , phe 16 providing & fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. , phe 17 providing and fixing white vitreous china laboratory sink with c.i. brackets, c.p. brass chain with rubber plug, 40 mm c.p brass waste and 40mm c.p. brass trap with necessary c.p. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required :size 600x450x200 mm , phe 18 providing and fixing cp brass single lever telephonic wall mixer of quality & make as approved by engineer in charge . a ) 15 mm nominal dia. , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 21 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 24 two or more coats on new work over an under coat ofsuitable shade with ordinary paint of approved brand andmanufacturetwo more coast on new work , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm.clear depth and 250mm apron including cost of e / w. involved with 75mmcement concrete ( 1:4:8 ) over one brick designation 100 a flat soling inproper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 8 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia. exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 11 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 450 mm dia rcc pipe , ex. phe 12 inside size 120x90 cm and 90 cm deep including c.i. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg ) :with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , ex. phe 13 providing and fixing square mouth sw gully trap grade ‘a’ complete ci grating brick masonry chamber with bricks of class designation 75 and water tight ci cover with frame of 300 x 300 mm size ( inside ) the weight of cover to be not less than 13.00 kg and frame to be not less than 5 kg. as per standard design. ( cover min. 4.5 kg & frame min.2.7 kg ) 180x150 mm size p type with fps bricks , ex. phe 14 constructing masonry chamber 30x30x50 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement:4 coarce sand ) for stop cock complete with c.i. surface box 100x100x75mm ( inside ) with locking arrangement and rcc top slab 1:2:4 mix ( 1 cement : 2 corase sand: 4 graded stonr aggregate 20mm nominal size ) necessary excavation foundation concret 1:5:10 ( 1 cement:5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortor 1:3 ( 1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design. , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , ex. phe 16 structual steel work welded in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. , ex. phe 17 making connection of gi distribution branch with gi main of 50 80mm nominal bore by providing and fixing tee, including cutting and threading the pipe etc. complete. , rain water harvesting 1 boring / drilling bore well of required dia for casing / strainer pipe, bysuitable method prescribed in is:2800 ( part i ) , including collecting sample from different strata , preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90m depth below ground level.300 mm dia , rain water harvesting 2 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150mm nominal size dia , rain water harvesting 3 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well screen ( rms ) pipes with ribs, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150 mm nominal size dia , rain water harvesting 4 supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 5 supplying, filling, spreading & levelling gravel of size range 5mm to 10mm, in recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 7 providing and fixing bail plug / bottom plug of required dia to the bottom of pipe assembly of tube well as per is:2800 ( part i ) . 100 mm dia , rain water harvesting 8 making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and s.w. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , rain water harvesting 9 constructing soak pit 1.20x1.20x1.20 m filled with brickbats including s.w. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , tubewell 1 boring / drilling bore well of required dia for casing / strainer pipe, bysuitable method prescribed in is:2800 ( part i ) , including collecting sample from different strata , preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90m depth below ground level.300 mm dia , tubewell 2 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150mm nominal size dia , tubewell 3 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.100mm nominal size dia , tubewell 4 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well screen ( rms ) pipes with ribs, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.100 mm nominal size dia , tubewell 5 supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , tubewell 6 providing and fixing bail plug / bottom plug of required dia to the bottom of pipe assembly of tube well as per is:2800 ( part i ) . 100 mm dia , submersible pump 35m deep boring with casing and pipe. supply of pipe etc supplying & installation of suitable 2hp submersible pump b.s or k.s.bor equivalent make with finolex cable 1x3x2.5 squmm ( upto 50mtr ) withflexible conduit 25mm dia, electrical out door pannel with required electrical fitting such as mcb of 0 25amp ( havell or indocopp or mds make ) , volt & ampere meter ( ae make ) , single phase preventer ( minilac or vsp 1 make ) starter ( l&t or bch make ) etc of approved make, 40mm hdpe pipe ( 25 mtr ) and all accessories complete as per requirement of site. , water purifier and cooler 1 fitting and fixing single faucet storage type water cooler ( size 461 mm wide x 582 mm deep x 1217 mm height, weight 46 kg ) fully stainless body having storage capacity of 40 ltrs, cooling capacity of 40 ltrs. / hr. with hermetic type compressor, gas cooled motor equipped with over load protector, condensor for propeller type, thermostat autometically controlled temperature, refrigerent r 22, 230 volt, single phase 50 hertz, maximum current 2.3 amp including plug top and electrical lead wire connection upto 3 metres from the cooler, water inlet and drain out connections complete in all respects of voltas model no 40 / 40 tushar pss type or similar type of approved make. , water purifier and cooler 2 fitting and fixing water purifier for drinking purpose of capacity 6 litres / min, 5 purification system with reverse osmosis system with ultra ventilated membrane, tds500 to 2000 mgl / ppm, auto shut off with microswitch float manual flush facility, tds reduction 90% having automatic backwash system with filteration unit along with all accessories including plug top and electrical lead wire connection upto 3 metres from the purifier, water inlet and drain out connections complete in all respects similar to aquaguard or similar approved make ( model aquasure elegant ro water purifier of size width 360 mm x height 430 mm x depth 235 mm and weight 8.5 kg ) . , fire extinguisher 1 providing and fixing carbon di oxide type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. capacity 4.5 kg. , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 6.0 kg. , electrical 1 wiring for light point / fan point / exhaust fan point / call bellpoint with 1.5 sq.mm frls pvc insulated copper conductorsingle core cable in surface / recessed steel conduit, withmodular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. group c , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , pvc conduit 1 supplying and fixing of following sizes of medium class 20mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , pvc conduit 2 supplying and fixing of following sizes of medium class 32mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , pvc conduit 3 supplying and fixing of following sizes of medium class 50mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , electrical 4 wiring for light / power plug with 2x4 sq. mm frls pvcinsulated copper conductor single core cable in surface / recessed conduit alongwith 1 no. 4 sq. mm frls pvcinsulated copper conductor single core cable for loop earthingas required. , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 4 x 6 sq. mm + 2 x 6 sq. mm earth wire , wiring frls pvc insulated copper conductor 4 4 x 10 sq. mm + 2 x 6 sq. mm earth wire , wiring frls pvc insulated copper conductor 5 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 1 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 3 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 4 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 2 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 3 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 4 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 5 telephone socket outlet , s / f modular switch / socket on the existing modular plate 6 tv antenna socket outlet , s / f modular switch / socket on the existing modular plate 7 bell push , electrical 5 supplying & fixing suitable size gi box wih modular plate and cover in front on surface or in recess including providing and fixing 25 a modular socket outlet and 25 a modular sp mcb, “c” curve including connections, painting etc. as required. ( for ac / geyser ) , electrical 6 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface / recessed steel / pvc conduit as required. , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 11 supplying and fixing 20 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. , electrical 12 supplying and fixing 30 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , electrical 14 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 12 way , double door , electrical 15 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 16 way, double door , electrical 16 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 6 way ( 4 + 18 ) , double door , electrical 17 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way ( 4 + 24 ) , double door , electrical 18 supplying and fixing of following ways surface / recess mounting, vertical type, 415 v, tpn mcb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 a tinned copper bus bar, common neutral link, earth bar, din bar for mounting mcbs ( but without mcbs and incomer ) as required . ( note : vertical type mcb tpdb is normally usedwhere 3 phase outlets are required. ) 4 way ( 4 + 12 ) , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 63a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 100a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , l / f pvc sheathed / xlpe power cable in trench laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 95 sq. mm and upto 185 sq. mm , l / f pvc sheathed / xlpe power cable in trench 1 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 185 sq. mm and upto 400 sq. mm , l / f pvc sheathed / xlpe power cable over cable tray upto 35 sq. mm ( clamped with 1mm thick saddle ) , l / f pvc sheathed / xlpe power cable over cable tray 2 above 35 sq. mm and upto 95 sq. mm ( clamped with 25x3mm ms flat clamp ) , l / f pvc sheathed / xlpe power cable over cable tray 3 above 95 sq. mm and upto 185 sq. mm ( clamped with 25 / 40x3mm ms flat clamp ) , l / f pvc sheathed / xlpe power cable over cable tray 4 above 185 sq. mm and upto 400 sq. mm ( clamped with 40x3mm ms flat clamp ) , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 3.5c x 300 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 1 3.5c x 240 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 2 3.5c x 120 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 3 3.5c x 95 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 4 3.5c x 50 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 5 4c x 35 sqmm aluminium conductor cable a2xfy , cable tray supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 100 mm width x 50 mm depth x 1.6 mm thickness , cable tray 1 supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 300 mm width x 50 mm depth x 1.6 mm thickness , cable tray 2 supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 600 mm width x 62.5 mm depth x 2.0 mm thickness , cable tray “bends” supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.100 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 1 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.150 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 2 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.300 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 3 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.450 mm width x 50 mm depth x 2 mm thickness , cable tray “bends” 4 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.600 mm width x 62.5 mm depth x 2.0 mm thickness , mv cable supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 300 sqmm, aluminium conductor cable a2xfy , mv cable 1 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 240 sqmm, aluminium conductor cable a2xfy , mv cable 2 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 120 sqmm, aluminium conductor cable a2xfy , mv cable 3 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 95 sqmm, aluminium conductor cable a2xfy , earthing earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 1 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. , earthing 2 earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. , earthing 3 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 4 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , earthing 5 providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required. , earthing 6 providing and fixing earth bus of 50 mm x 5 mm copper strip on surface for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 4 supplying and fixing recess mounted 12 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 6 supply, installation, testing and commissioning of 400 mm sweep, 65w, blade material aluminium blades , speed & oscillation 3 speed, pull cord for speed and oscillation.air delivery minimum 72 m³ / min, speed minimun 1350 revolution per minute.suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , fiting & fixtures 8 supplying installation testing & commissioning ofb22 based 9w led 3 star bulb with 850 lumen, 6k color temperature including holder. , fiting & fixtures 9 supplying installation testing & commissioning of black painted extruded aluminium housing. green / red led’s mounted inside the housing. laser engraved signage matter on single / double acrylic sheet fixed on one side suitable for wall / ceiling / suspension type single / double sided display. in double sided version black paper is inserted. ni cd battery back up to 2 hrs. ( charged up to 8 10 hrs ) .mounting strings provided for pendent mounting operating voltage 150 280v ac ambient operating temperature. – 0 to 450c ingress protection – ip42.including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required.   220208 besl 03 led ssd wbb green 240 3 8wor220209 besl 03 led ssd wbb red 240 3 8wor220210 besl 03 led dsd wbb green 240 3 8wor220211 besl 03 led dsd wbb red 240 3 8w , fiting & fixtures 10 supply, installation, testing & erecting of ip66 bulkhead surface type lighting fixture 10w made up of pressure die cast aluminium housing and polyster powder coated die cast aluminium with high quality polycarbonate diffuser in opal finish for glare free light distribution.high efficiency long life led module with smd led package mounted on mcpcb with lumen efficacy of >95 lm / w with system lumen 950. powered by integral electronic led driver with apfc with low thd output short / open circuit protection. cct 5700, cri>80, system efficacy>90lm / w, thd<15%, pf>.95, ip66, ik 10, life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz.including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. cat ref: havells : hexaft10wled857ssymbopc or approved equivalent. , civil & misc works1 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. , civil & misc works2 providing and fixing h.t. danger notice plate of 250 mm x 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. , civil & misc works3 supplying and making cable route marker with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm x 60 cm at the bottom and 50 cm x 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. , civil & misc works4 supplying and fixing cable route marker with 10 cm x 10 cm x 5 mm thick g.i. plate with inscription there on, bolted / welded to 35 mm x 35 mm x 6 mm angle iron, 60 cm long and fixing the same in ground as required. , civil & misc works5 providing & fixing in position 1000 mm wide , electrical insulating rubber mats as per is 15652:2006, 2 mm thick, suitable up to 1.1 kv , fire retardant, no effect of acids, alkalis and transformer oils, moisture proof, high tensile strengthandtexture finish / cloth impression ( anti slip , marking on top ) , civil & misc works6 supply & fixing shock treatment chart duly mounted on a wooden frame with 5 mm thick glass as required ( approx front area 1.20 sq metre ) , 40 kvaups supplying, installation, testing and commissioningof online double conversion fully microprocessor based , indoor type, compact ups system of following rating with igbt based pwm technology to achieve thd < 3% and input power factor of greater than 0.95 at 50% loading, suitable for three phase ac input voltage 380 v to 440 v, 50 hz +3% / 3 % and three phase ac output voltage 415 ± 1% volts & frequency 50 ± 0.5 hz , inbuilt isolation transformer, necessary vrla batteries of suitable size having 30 minutes back up time , mounting rack including and suitable size connecting cable ( for ups to battery and battery to battery ) , static and maintenance bypass switch, snmp card for rs232 / ethernet ip computability for operation and monitoring etc. with all components as mentioned , specifications, complete as required.note : concerning vendor needs to furnish the battery sizing calculations at the time of ga approval and battery size has to be as per the approved ga drawing. , external lighting 1 supply and erection of 4 metre height hot dipgalvanized octagonal street light pole with followingarm with top dia 70 mm and bottom dia a / f 130 mm, made of 3 mm thick sheet along with base plate of size220 x 220 x 12 mm , small door opening for junctionbox mounting with mcb & connector, cement concreteof 1:3:6 including excavation, refilling and suitable sizefoundation bolts with template and all complete jobasrequired. ( but without pole collar ) single arm , external lighting 2 supplying and fixing 40 / 45 watt led type street lightwith die cast aluminium housing for ingress protectionof ip65 and complete with all accessories etc, onpole / building including connection with fr pvcinsulated copper conductor cable and earthing thebody etc. as required. , ip based cctv system 1 sitc of 2 megapixel @ 25fps, h.265 ip bullet camera, 1 / 2.9 cmos with 2.8~12mm varifocal lens, 0 lux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 2 sitc of 2 megapixel @ 25fps, h.265 ip dome camera, 1 / 2.9 cmos with 3.6 fixed mm 0 lux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 3 sitc of 2 megapixel @ 25fps, ptz camera h.265 ip dome camera, 1 / 2.9 cmos with 2.6 fixed lenslux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 4 sitc of 32ch 4k ivr , h.265 / h.264 • 1080p real time • 4k display • dual lan • 8x hdd • raid •web plugin free h.265 / h.264 compression technology 4k display for clear monitoring up to 1080p 16ch decoding ability smart search ii smart vca event searchsupport raid 0, 1, 5 supported to prevent from recording data loss browsers supported: ie , smart functions : target count, electric fence, face detection, humaniod detection, retrograde detection, leave position detectio output, local & network backup etc. complete as required. , cctv 5 sitc of harddiskdrive8tb, 24 / 7surveillance category only complete etc as required.etc.all complete , cctv 6 sitc of 55 led narrow bazel for monitoring for nvr server etc. all complete. , cctv 7 sitc of rj 45 outlets near the cameras etc. all complete. etc. all complete. , cctv 8 sitc of cat 6 patch cords 1 meter high quality four pair twisted stranded cable terminated with rj45 modular plugs at both the ends. , signage 1 providing & fixing of building direction signage mounted on pole, with pole of 100x100mm shs ( square hollow section ) of height of 5600mm, and sign size of 900x1050, sign made of aluminiu c section of 60mm with internal framing to support the frame in ms tubes hollow section, frame work duly painted with anti rust coatings, with facia of 3mm thick exterior grade aluminium composite panel, cladded with uv cured digital printed retroreflective sheet of 3m make, and back panel of 3mm exterior grade acp, all pipes to be painted in approved color. cost shall includecost towards installation, including excuvation and filling up with specified pcc and fixing of foundation bolts as specified, also it shall include the designing charges.all complete as per direction by engineer in charge. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , 2 tr air conditioning 1 split ac ( inverter model ) : supply, installation, testing, commissioning of split type wall mounted air conditioning units of following capacity including inddor, outdoor unit fitted with inverter based rotary compressor fitted with rotary compressor, copper condensor and first charge refrigent r410a / eco friendly green gas only, all complete including all electrical connections to the electrical power supply system of the building, includingbut not limited to supply of all electrical plugs, etc., as necessary, lengthening of all electrical wires of ac units ( both indoor and outdoor ) , drain pipe andincluding suitable voltage stabilisers, etc. so as to place them in a concealed manner in the desired position. the copper pipes and electrical cables shall be concealed in approved manner and neatly run in straight lines in a workman like manner with proper supports. complete supply and installation of split2 tr star rating 3 star , refrigerant piping copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 25 mm od, wall thickness >= 1.2 mm ( insulation 19 mm thick ) , refrigerant piping 1 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 19.1 mm od, wall thickness >= 1.0 mm ( insulation 13 mm thick ) , refrigerant piping 2 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 15.9 mm od, wall thickness >= 0.8 mm ( insulation 13 mm thick ) , refrigerant piping 3 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 9.5 mm od, wall thickness >= 0.8 mm ( insulation 13 mm thick ) , drain piping providing and fixing of cpvc 6 kg / cm2 drainpiping complete with fittings, supports, 6 mm thick closed cell elastomeric insulation as per specifications and drawings. 20 mm , drain piping 1 providing and fixing of cpvc 6 kg / cm2 drainpiping complete with fittings, supports, 6 mm thick closed cell elastomeric insulation as per specifications and drawings. 32 mm , main oxygen manifold supply, installation, testing and commissioning of following gas manifold system ( excluding cylinders ) . the manifold is configured for designed numbers of cylinders and is suitable to withstand a pressure of 145 kg / cm2, along withhigh pressure copper annealed tail pipes with end brass adapter suitable for cylinders and manifold. top frame comprising of high pressure copper pipes of size 1 / 2” nb x 15swg with high pressure brass fittings made of high tensile brass and connections through nonreturn valves, the design of middle and bottomframes is provided to fit both round and flat bottom cylinders safely. the manifold is tested ( hydraulically ) at 3500 psig. ( it should be ce and iso 13485 certified ) mani fold oxygen manifold 6 + 6 cylinder banks complete with nrv, middle frame, bottom frame with ce marked, , emergency manifold emergency oxygen manifold 01 + 01 cylinder emergency manifold with complete regulator, nrv, middle frame & bottom frame, , control panelfor oxygen fully automatic three port control panel for oxygen supply, installation, testing and commissioning of automatic manifold control panel would provide a duty or standby gas supply from two cylinder banks with automaticchangeover the manifold indicates local status and has a remote indicator facility. automaticmanifold control panel would be designed to supply the mgps with a constant pressure supply via a control panel form two equal banks of cylinders and the changeover from the ‘duty’ to the ‘standby’ bank of cylinders would beautomatic. automatic changeover from the duty to the standby bank would occur at a cylinder pressure that will ensure the maximum usage of the contents of the duty bank. the changeover unit would be provided with monitoring todetect and display: duty bank operating, duty bank empty, standby bank operating, and standby bank below 10 % when the duty bank is empty, reserve bank low, pipeline pressure fault. there would be facility to connect liquidoxygen supply ( i.e. three port control panel ) ( it should be ce and iso 13485 certified ) fully automatic three port control panel for oxygen , emergency manifold line regulator emergency manifold line regulator supply, installation, testing and commissioning of emergency manifold line regulator i n p u t p r e s s u r e 1 5 0 k g / c m 2 working pressure 4 kg / cm2 it should be ce and iso 13485 certified.oxygen input pressure 150 kg / cm2 working pressure 4 kg / cm2capacity : 1500 lpm , cylinderconnectingpipe ( pig tail ) supply, installation, testing and commissioning of cylinder connecting pipe ( pig tail ) made up of flexible ss hose with safety cord 5 / 8 inch bsp gland nut and one side 1 / 2 inch bsp internal threads having one meter length. ( oxygen 24 , n2o 10, co2 4 ) , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , medical air ( 4 bar ) outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve, supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified.42mm , isolation valve 2 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 28mm , isolation valve 3 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 22mm , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness , pipeline 4 medical grade copper pipeline ( in mtrs. ) as per en 13348, 28 mm ( od ) x 0.9 mm thickness , pipeline 5 medical grade copper pipeline ( in mtrs. ) as per en 13348, 42 mm ( od ) x 1.2 mm thickness , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 2268 mm x ( w ) 922 mm x ( h ) 610 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , paediatric bed with mattress paediatric bed of overall sizes in mm: 1500 ( l ) x 850 ( w ) x 1210 ( h ) flat single section bed with grille frame on 4 sides.suitable for children up to 12 years.drop down grill frame on both sides for protection of the patient.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral white , bed side locker type i over all dimension :402mmlx422mm wx840mm ht .locker should have one cabinet and one drawer unit .both provided with cam lock .there should be gap between drawer and unit to keep general items for frequesnt use castors are provided for easy handling .drawer made up of crca sheet 1 mm thick and has ball slide for easy operation .top ss 304 sheet 0.8 mm thick castors 50 mmdia , hamdle abs ..powder coating of epoxy polyester , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , strecher on trolley type i 2005mm ( l ) x666mm ( w ) x827mm ( h ) .the trolley should be made of 31.75 and 25.4 mm dia 1.6 mm thick erw tube.holder for stretcher should be made up of mild steel.castor should be of 200 mm dia , diagonal locking castor.stretcher should be made up oferw tubeof dia 25.4 mm and thickness 1.6 mm.top sheet should be made of crca sheetof thickness 1.2 mm with contour shape to accommodate patient.iv pole holder should be made ofms .maximum safe work load should be 135 kg.to ensure qood quality welding co2 argonprocess should be adhered to.all metal componentsshould be pre treated with zinc phosphating in 9 tank porcess and then powder coated with anti microbialepoxy polyster powder coating.goods should be supplied in knocked down construction to reduce carbon emission. performance test :proof loading test , cycle tests , impact test, salt spray test, castor break test, the manufacturer should compilant with iso 9001, 14001, 13485, ohsas 1800 and ce certification. , doctor desk type x s / f / f executive table main desk should be of dimesion : 1350w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. side panels : ( black ) made form 18mm thick plt with pvc lipping.modesty panel : made form 18mm thick plt with pvc lipping. bigger upper panel in black and smaller lower panel in white cedar. made from 18mm thick plt with pvc lipping. mobile pedestal : one box and one filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , chair type iii s / f / f executive chair1 ) seat / back assembly: the seat and back are made up of 1.2 cm. thick hot pressed plywood, upholstered withfabric upholstery covers and moulded polyurethane foam. the back foam is designed with contoured lumbar support for extra comfort. the seat has extra thick foam on front edge to give comfort to popliteal area.high back size : 47.5 cm ( w ) x 69.5 cm ( h ) seat size : 47.0 cm. ( w ) x 48.0 cm. ( d ) 2 ) polyurethane foam: the polyurethane foam is moulded with density = 45 + / 2 kg / m 3and hardness = 20 + / 2at 25% compression. 3 ) armrests: the one piece armrests are injection moulded from black co polymer polypropylene. 4 ) center tilt synchro mechanism : the mechanism is designed with the following features:• 360 revolving type. • upright position locking. • tilt tension adjustment.• seat / back tilting ratio of 1:3 ( 60 seat tilt / 180 back tilt ) . 5 ) pneumatic height adjustment : the pneumatic height adjustment has anadjustment stroke of 12.0 cm. 6 ) telescopic bellow assembly : the bellow is 3 piece telescopic type and injection moulded in black polypropylene. 7 ) pedestal assembly : . , staff / visitor chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck .3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement.mx load bearing capacity should be 10 kg. , hospital curtain tracks & i.v. tree system supply installation testing & commissioning of cubical tracks system made of powder coated aluminium alloy, stain free polyster fabric , water repellent curtains , smooth movement , non sticking runnner with stainless steel hooks made from mirror finish stainless steel , adjustable height with all accessories. total quantity : 1...

Health And Family Welfare Department - Bihar

30458807 bids are invited for pile boring, providing and installation bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using direct mud circulation ( dmc ) or bailer and chisel technique by tripod and mechanical winch machine all complete, including removal of excavated earth with all its lifts and leads ( length of pile for payment shall be measured up to bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , upvc door providing and fixing of factory made upvc white colour casement door, upvc multichambered extruted frame, sash and mullion profile. frame duly reinforced with 1.2mm gi section box tpe chamber and sash with 1.5mm thick gi section ( ± 0.2mm ) based on wind load calculations ( shape and size according to upvc profiles ) , appropiate dimentions of upvc extruded glazing bead, epdm gasket ( k / o type ) , seperate drainage system, ss34 grade friction hinges 2d / 3d plate hinges, zinc alloy ( white powder coated ) casement handle, gi fastener 8x100 mm size for fixing frame to finish wall, plastic packer and caps and necessary steel screws etc.profile of frame and sash shall be metered cut and fusion welded at all corners, mullion shall be also fusion welded / joined mechanically including drilling of holes for fixing hardware and drainage of water etc. after fixing of frames , gap between frame and adjascent wall shall be filled with pu foaam / backer rod required size and the approved quantity. after that sealed with weather proof silicon sealant at both side, all complete as per approved drawing and direction of eic , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 1 providing and laying vitrified floor tiles in different sizes ( thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including grouting the joints with white cement and matching pigments etc., complete. size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge :flamed finish granite stone slab jet black, cherry red, elitebrown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item ( galvanised@80gsm ) 50 mm long 8mmouter diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’ , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975. the wind load shall be as per provisions of is 875 ( part iii ) . lgsfs frame shall be designed as per is: 801 using commercially available software such as frame cad pro 11.7 / staad pro v8i / architekv2.5.16 / revit architecture 2011 or equivalent. proper usage of connection accessories like heavy duty tension ties, light duty hold ons, twist straps ( to connect truss with wall frames ) , strong tie, tie rod, h brackets, boxing sections, l shaped angles for better structural stability. the framing section shall be cold form c type having minimum web depth 89 mm x 39mm flange x 11mm lip in required length as per structural design requirement duly punched with dimple / slot at required locations as per approved drawings. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm and. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , face panel providing and fixing in all exterior face panels breathable vapour barrier underneath the cementfiber board as per national building code 2009 complete as per direction of engineer in charge. , lap siding supplying and installation of moisture resistant / fire resistantlap siding 8 mm thick and width as per standard sizes made ofiber cement board with embossed decorative finish to give pleasing exterior fixed horizontally with staggered joints including minimum over lapof 32 mm external cement fibre boardconforming to is 14862:2000 offixed with self drilling / taping screws / fastners of approved make. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1 new work ( two or more coats ) over and including water tinnable priming coat with cement primer , ex. paint finishing walls with textured exterior paint of required shade : new work ( two or more coats applied @ 3.28 ltr / 10 sqm ) over and including priming coat of exterior primer applied @ 2.20kg / 10 sqm sqm , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel 1 steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , road providing and laying c.c. pavement of mix m 25 with ready mixed concrete from batching plant. the ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc.complete as per specifications and directions of engineer in charge. ( the panel shuttering work shall be paid for separately ) . ( note: cement content considered in this item is @ 330 kg / cum. excess / less cement used as per design mix is payable / recoverableseparately ) . , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 1 providing & fixing stone slab table rubbed, edges rounded and polished of size 75 x 50cm deep and 1.8 cm thick fixed in urinal patitions by cutting chase of appropriate width with chase cutter and embedding the stone in chase with epoxy grout or with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregste 6mm nominal size ) as per engineer in charge and finished smooth white agaria marble stone , phe 2 providing and fixing salem stainless steel a isi 304 ( 18 / 8 ) kitchen sink as per is: 13983 with ci brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required. kitchen sink with drain board510x1040mm bowl depth 200mm. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing:rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixturescomplete, including cutting and making good the walls andlevel whitep.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings andfloors wherever required :white vitreous china orissa pattern w.c. pan of size580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 9 providing and fixing cp brass 32mm size bottle trap of approved quality & make and as per the direction of engineer in charge.. ( sink & urinal ) , phe 10 providing & fixingptmt towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealedfittings arrangement of approved quality and colour weighing not less than 88 gms , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size 660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 15 providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water ( 250 ml & 500 ml consumption ) , having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of engineer in charge.. , phe 16 providing & fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. , phe 17 providing and fixing white vitreous china laboratory sink with c.i. brackets, c.p. brass chain with rubber plug, 40 mm c.p brass waste and 40mm c.p. brass trap with necessary c.p. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required :size 600x450x200 mm , phe 18 providing and fixing cp brass single lever telephonic wall mixer of quality & make as approved by engineer in charge . a ) 15 mm nominal dia. , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 21 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 24 two or more coats on new work over an under coat ofsuitable shade with ordinary paint of approved brand andmanufacturetwo more coast on new work , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm.clear depth and 250mm apron including cost of e / w. involved with 75mmcement concrete ( 1:4:8 ) over one brick designation 100 a flat soling inproper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 8 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia. exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 11 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 450 mm dia rcc pipe , ex. phe 12 inside size 120x90 cm and 90 cm deep including c.i. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg ) :with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , ex. phe 13 providing and fixing square mouth sw gully trap grade ‘a’ complete ci grating brick masonry chamber with bricks of class designation 75 and water tight ci cover with frame of 300 x 300 mm size ( inside ) the weight of cover to be not less than 13.00 kg and frame to be not less than 5 kg. as per standard design. ( cover min. 4.5 kg & frame min.2.7 kg ) 180x150 mm size p type with fps bricks , ex. phe 14 constructing masonry chamber 30x30x50 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement:4 coarce sand ) for stop cock complete with c.i. surface box 100x100x75mm ( inside ) with locking arrangement and rcc top slab 1:2:4 mix ( 1 cement : 2 corase sand: 4 graded stonr aggregate 20mm nominal size ) necessary excavation foundation concret 1:5:10 ( 1 cement:5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortor 1:3 ( 1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design. , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , ex. phe 16 structual steel work welded in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. , ex. phe 17 making connection of gi distribution branch with gi main of 50 80mm nominal bore by providing and fixing tee, including cutting and threading the pipe etc. complete. , rain water harvesting 1 boring / drilling bore well of required dia for casing / strainer pipe, bysuitable method prescribed in is:2800 ( part i ) , including collecting sample from different strata , preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90m depth below ground level.300 mm dia , rain water harvesting 2 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150mm nominal size dia , rain water harvesting 3 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well screen ( rms ) pipes with ribs, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150 mm nominal size dia , rain water harvesting 4 supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 5 supplying, filling, spreading & levelling gravel of size range 5mm to 10mm, in recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 7 providing and fixing bail plug / bottom plug of required dia to the bottom of pipe assembly of tube well as per is:2800 ( part i ) . 100 mm dia , rain water harvesting 8 making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and s.w. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , rain water harvesting 9 constructing soak pit 1.20x1.20x1.20 m filled with brickbats including s.w. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , tubewell 1 boring / drilling bore well of required dia for casing / strainer pipe, bysuitable method prescribed in is:2800 ( part i ) , including collecting sample from different strata , preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90m depth below ground level.300 mm dia , tubewell 2 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150mm nominal size dia , tubewell 3 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.100mm nominal size dia , tubewell 4 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well screen ( rms ) pipes with ribs, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.100 mm nominal size dia , tubewell 5 supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , tubewell 6 providing and fixing bail plug / bottom plug of required dia to the bottom of pipe assembly of tube well as per is:2800 ( part i ) . 100 mm dia , submersible pump 35m deep boring with casing and pipe. supply of pipe etc supplying & installation of suitable 2hp submersible pump b.s or k.s.bor equivalent make with finolex cable 1x3x2.5 squmm ( upto 50mtr ) withflexible conduit 25mm dia, electrical out door pannel with required electrical fitting such as mcb of 0 25amp ( havell or indocopp or mds make ) , volt & ampere meter ( ae make ) , single phase preventer ( minilac or vsp 1 make ) starter ( l&t or bch make ) etc of approved make, 40mm hdpe pipe ( 25 mtr ) and all accessories complete as per requirement of site. , water purifier and cooler 1 fitting and fixing single faucet storage type water cooler ( size 461 mm wide x 582 mm deep x 1217 mm height, weight 46 kg ) fully stainless body having storage capacity of 40 ltrs, cooling capacity of 40 ltrs. / hr. with hermetic type compressor, gas cooled motor equipped with over load protector, condensor for propeller type, thermostat autometically controlled temperature, refrigerent r 22, 230 volt, single phase 50 hertz, maximum current 2.3 amp including plug top and electrical lead wire connection upto 3 metres from the cooler, water inlet and drain out connections complete in all respects of voltas model no 40 / 40 tushar pss type or similar type of approved make. , water purifier and cooler 2 fitting and fixing water purifier for drinking purpose of capacity 6 litres / min, 5 purification system with reverse osmosis system with ultra ventilated membrane, tds500 to 2000 mgl / ppm, auto shut off with microswitch float manual flush facility, tds reduction 90% having automatic backwash system with filteration unit along with all accessories including plug top and electrical lead wire connection upto 3 metres from the purifier, water inlet and drain out connections complete in all respects similar to aquaguard or similar approved make ( model aquasure elegant ro water purifier of size width 360 mm x height 430 mm x depth 235 mm and weight 8.5 kg ) . , fire extinguisher 1 providing and fixing carbon di oxide type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. capacity 4.5 kg. , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 6.0 kg. , electrical 1 wiring for light point / fan point / exhaust fan point / call bellpoint with 1.5 sq.mm frls pvc insulated copper conductorsingle core cable in surface / recessed steel conduit, withmodular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. group c , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , pvc conduit 1 supplying and fixing of following sizes of medium class 20mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , pvc conduit 2 supplying and fixing of following sizes of medium class 32mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , pvc conduit 3 supplying and fixing of following sizes of medium class 50mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , electrical 4 wiring for light / power plug with 2x4 sq. mm frls pvcinsulated copper conductor single core cable in surface / recessed conduit alongwith 1 no. 4 sq. mm frls pvcinsulated copper conductor single core cable for loop earthingas required. , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 4 x 6 sq. mm + 2 x 6 sq. mm earth wire , wiring frls pvc insulated copper conductor 4 4 x 10 sq. mm + 2 x 6 sq. mm earth wire , wiring frls pvc insulated copper conductor 5 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 1 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 3 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 4 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 2 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 3 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 4 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 5 telephone socket outlet , s / f modular switch / socket on the existing modular plate 6 tv antenna socket outlet , s / f modular switch / socket on the existing modular plate 7 bell push , electrical 5 supplying & fixing suitable size gi box wih modular plate and cover in front on surface or in recess including providing and fixing 25 a modular socket outlet and 25 a modular sp mcb, “c” curve including connections, painting etc. as required. ( for ac / geyser ) , electrical 6 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface / recessed steel / pvc conduit as required. , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 11 supplying and fixing 20 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. , electrical 12 supplying and fixing 30 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , electrical 14 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 12 way , double door , electrical 15 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 16 way, double door , electrical 16 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 6 way ( 4 + 18 ) , double door , electrical 17 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way ( 4 + 24 ) , double door , electrical 18 supplying and fixing of following ways surface / recess mounting, vertical type, 415 v, tpn mcb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 a tinned copper bus bar, common neutral link, earth bar, din bar for mounting mcbs ( but without mcbs and incomer ) as required . ( note : vertical type mcb tpdb is normally usedwhere 3 phase outlets are required. ) 4 way ( 4 + 12 ) , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 63a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 100a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , l / f pvc sheathed / xlpe power cable in trench laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 95 sq. mm and upto 185 sq. mm , l / f pvc sheathed / xlpe power cable in trench 1 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 185 sq. mm and upto 400 sq. mm , l / f pvc sheathed / xlpe power cable over cable tray upto 35 sq. mm ( clamped with 1mm thick saddle ) , l / f pvc sheathed / xlpe power cable over cable tray 2 above 35 sq. mm and upto 95 sq. mm ( clamped with 25x3mm ms flat clamp ) , l / f pvc sheathed / xlpe power cable over cable tray 3 above 95 sq. mm and upto 185 sq. mm ( clamped with 25 / 40x3mm ms flat clamp ) , l / f pvc sheathed / xlpe power cable over cable tray 4 above 185 sq. mm and upto 400 sq. mm ( clamped with 40x3mm ms flat clamp ) , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 3.5c x 300 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 1 3.5c x 240 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 2 3.5c x 120 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 3 3.5c x 95 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 4 3.5c x 50 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 5 4c x 35 sqmm aluminium conductor cable a2xfy , cable tray supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 100 mm width x 50 mm depth x 1.6 mm thickness , cable tray 1 supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 300 mm width x 50 mm depth x 1.6 mm thickness , cable tray 2 supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 600 mm width x 62.5 mm depth x 2.0 mm thickness , cable tray “bends” supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.100 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 1 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.150 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 2 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.300 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 3 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.450 mm width x 50 mm depth x 2 mm thickness , cable tray “bends” 4 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.600 mm width x 62.5 mm depth x 2.0 mm thickness , mv cable supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 300 sqmm, aluminium conductor cable a2xfy , mv cable 1 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 240 sqmm, aluminium conductor cable a2xfy , mv cable 2 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 120 sqmm, aluminium conductor cable a2xfy , mv cable 3 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 95 sqmm, aluminium conductor cable a2xfy , earthing earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 1 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. , earthing 2 earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. , earthing 3 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 4 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , earthing 5 providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required. , earthing 6 providing and fixing earth bus of 50 mm x 5 mm copper strip on surface for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 4 supplying and fixing recess mounted 12 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 6 supply, installation, testing and commissioning of 400 mm sweep, 65w, blade material aluminium blades , speed & oscillation 3 speed, pull cord for speed and oscillation.air delivery minimum 72 m³ / min, speed minimun 1350 revolution per minute.suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , fiting & fixtures 8 supplying installation testing & commissioning ofb22 based 9w led 3 star bulb with 850 lumen, 6k color temperature including holder. , fiting & fixtures 9 supplying installation testing & commissioning of black painted extruded aluminium housing. green / red led’s mounted inside the housing. laser engraved signage matter on single / double acrylic sheet fixed on one side suitable for wall / ceiling / suspension type single / double sided display. in double sided version black paper is inserted. ni cd battery back up to 2 hrs. ( charged up to 8 10 hrs ) .mounting strings provided for pendent mounting operating voltage 150 280v ac ambient operating temperature. – 0 to 450c ingress protection – ip42.including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required.   220208 besl 03 led ssd wbb green 240 3 8wor220209 besl 03 led ssd wbb red 240 3 8wor220210 besl 03 led dsd wbb green 240 3 8wor220211 besl 03 led dsd wbb red 240 3 8w , fiting & fixtures 10 supply, installation, testing & erecting of ip66 bulkhead surface type lighting fixture 10w made up of pressure die cast aluminium housing and polyster powder coated die cast aluminium with high quality polycarbonate diffuser in opal finish for glare free light distribution.high efficiency long life led module with smd led package mounted on mcpcb with lumen efficacy of >95 lm / w with system lumen 950. powered by integral electronic led driver with apfc with low thd output short / open circuit protection. cct 5700, cri>80, system efficacy>90lm / w, thd<15%, pf>.95, ip66, ik 10, life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz.including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. cat ref: havells : hexaft10wled857ssymbopc or approved equivalent. , civil & misc works1 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. , civil & misc works2 providing and fixing h.t. danger notice plate of 250 mm x 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. , civil & misc works3 supplying and making cable route marker with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm x 60 cm at the bottom and 50 cm x 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. , civil & misc works4 supplying and fixing cable route marker with 10 cm x 10 cm x 5 mm thick g.i. plate with inscription there on, bolted / welded to 35 mm x 35 mm x 6 mm angle iron, 60 cm long and fixing the same in ground as required. , civil & misc works5 providing & fixing in position 1000 mm wide , electrical insulating rubber mats as per is 15652:2006, 2 mm thick, suitable up to 1.1 kv , fire retardant, no effect of acids, alkalis and transformer oils, moisture proof, high tensile strengthandtexture finish / cloth impression ( anti slip , marking on top ) , civil & misc works6 supply & fixing shock treatment chart duly mounted on a wooden frame with 5 mm thick glass as required ( approx front area 1.20 sq metre ) , 40 kvaups supplying, installation, testing and commissioningof online double conversion fully microprocessor based , indoor type, compact ups system of following rating with igbt based pwm technology to achieve thd < 3% and input power factor of greater than 0.95 at 50% loading, suitable for three phase ac input voltage 380 v to 440 v, 50 hz +3% / 3 % and three phase ac output voltage 415 ± 1% volts & frequency 50 ± 0.5 hz , inbuilt isolation transformer, necessary vrla batteries of suitable size having 30 minutes back up time , mounting rack including and suitable size connecting cable ( for ups to battery and battery to battery ) , static and maintenance bypass switch, snmp card for rs232 / ethernet ip computability for operation and monitoring etc. with all components as mentioned , specifications, complete as required.note : concerning vendor needs to furnish the battery sizing calculations at the time of ga approval and battery size has to be as per the approved ga drawing. , external lighting 1 supply and erection of 4 metre height hot dipgalvanized octagonal street light pole with followingarm with top dia 70 mm and bottom dia a / f 130 mm, made of 3 mm thick sheet along with base plate of size220 x 220 x 12 mm , small door opening for junctionbox mounting with mcb & connector, cement concreteof 1:3:6 including excavation, refilling and suitable sizefoundation bolts with template and all complete jobasrequired. ( but without pole collar ) single arm , external lighting 2 supplying and fixing 40 / 45 watt led type street lightwith die cast aluminium housing for ingress protectionof ip65 and complete with all accessories etc, onpole / building including connection with fr pvcinsulated copper conductor cable and earthing thebody etc. as required. , ip based cctv system 1 sitc of 2 megapixel @ 25fps, h.265 ip bullet camera, 1 / 2.9 cmos with 2.8~12mm varifocal lens, 0 lux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 2 sitc of 2 megapixel @ 25fps, h.265 ip dome camera, 1 / 2.9 cmos with 3.6 fixed mm 0 lux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 3 sitc of 2 megapixel @ 25fps, ptz camera h.265 ip dome camera, 1 / 2.9 cmos with 2.6 fixed lenslux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 4 sitc of 32ch 4k ivr , h.265 / h.264 • 1080p real time • 4k display • dual lan • 8x hdd • raid •web plugin free h.265 / h.264 compression technology 4k display for clear monitoring up to 1080p 16ch decoding ability smart search ii smart vca event searchsupport raid 0, 1, 5 supported to prevent from recording data loss browsers supported: ie , smart functions : target count, electric fence, face detection, humaniod detection, retrograde detection, leave position detectio output, local & network backup etc. complete as required. , cctv 5 sitc of harddiskdrive8tb, 24 / 7surveillance category only complete etc as required.etc.all complete , cctv 6 sitc of 55 led narrow bazel for monitoring for nvr server etc. all complete. , cctv 7 sitc of rj 45 outlets near the cameras etc. all complete. etc. all complete. , cctv 8 sitc of cat 6 patch cords 1 meter high quality four pair twisted stranded cable terminated with rj45 modular plugs at both the ends. , signage 1 providing & fixing of building direction signage mounted on pole, with pole of 100x100mm shs ( square hollow section ) of height of 5600mm, and sign size of 900x1050, sign made of aluminiu c section of 60mm with internal framing to support the frame in ms tubes hollow section, frame work duly painted with anti rust coatings, with facia of 3mm thick exterior grade aluminium composite panel, cladded with uv cured digital printed retroreflective sheet of 3m make, and back panel of 3mm exterior grade acp, all pipes to be painted in approved color. cost shall includecost towards installation, including excuvation and filling up with specified pcc and fixing of foundation bolts as specified, also it shall include the designing charges.all complete as per direction by engineer in charge. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , 2 tr air conditioning 1 split ac ( inverter model ) : supply, installation, testing, commissioning of split type wall mounted air conditioning units of following capacity including inddor, outdoor unit fitted with inverter based rotary compressor fitted with rotary compressor, copper condensor and first charge refrigent r410a / eco friendly green gas only, all complete including all electrical connections to the electrical power supply system of the building, includingbut not limited to supply of all electrical plugs, etc., as necessary, lengthening of all electrical wires of ac units ( both indoor and outdoor ) , drain pipe andincluding suitable voltage stabilisers, etc. so as to place them in a concealed manner in the desired position. the copper pipes and electrical cables shall be concealed in approved manner and neatly run in straight lines in a workman like manner with proper supports. complete supply and installation of split2 tr star rating 3 star , refrigerant piping copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 25 mm od, wall thickness >= 1.2 mm ( insulation 19 mm thick ) , refrigerant piping 1 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 19.1 mm od, wall thickness >= 1.0 mm ( insulation 13 mm thick ) , refrigerant piping 2 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 15.9 mm od, wall thickness >= 0.8 mm ( insulation 13 mm thick ) , refrigerant piping 3 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 9.5 mm od, wall thickness >= 0.8 mm ( insulation 13 mm thick ) , drain piping providing and fixing of cpvc 6 kg / cm2 drainpiping complete with fittings, supports, 6 mm thick closed cell elastomeric insulation as per specifications and drawings. 20 mm , drain piping 1 providing and fixing of cpvc 6 kg / cm2 drainpiping complete with fittings, supports, 6 mm thick closed cell elastomeric insulation as per specifications and drawings. 32 mm , main oxygen manifold supply, installation, testing and commissioning of following gas manifold system ( excluding cylinders ) . the manifold is configured for designed numbers of cylinders and is suitable to withstand a pressure of 145 kg / cm2, along withhigh pressure copper annealed tail pipes with end brass adapter suitable for cylinders and manifold. top frame comprising of high pressure copper pipes of size 1 / 2” nb x 15swg with high pressure brass fittings made of high tensile brass and connections through nonreturn valves, the design of middle and bottomframes is provided to fit both round and flat bottom cylinders safely. the manifold is tested ( hydraulically ) at 3500 psig. ( it should be ce and iso 13485 certified ) mani fold oxygen manifold 6 + 6 cylinder banks complete with nrv, middle frame, bottom frame with ce marked, , emergency manifold emergency oxygen manifold 01 + 01 cylinder emergency manifold with complete regulator, nrv, middle frame & bottom frame, , control panelfor oxygen fully automatic three port control panel for oxygen supply, installation, testing and commissioning of automatic manifold control panel would provide a duty or standby gas supply from two cylinder banks with automaticchangeover the manifold indicates local status and has a remote indicator facility. automaticmanifold control panel would be designed to supply the mgps with a constant pressure supply via a control panel form two equal banks of cylinders and the changeover from the ‘duty’ to the ‘standby’ bank of cylinders would beautomatic. automatic changeover from the duty to the standby bank would occur at a cylinder pressure that will ensure the maximum usage of the contents of the duty bank. the changeover unit would be provided with monitoring todetect and display: duty bank operating, duty bank empty, standby bank operating, and standby bank below 10 % when the duty bank is empty, reserve bank low, pipeline pressure fault. there would be facility to connect liquidoxygen supply ( i.e. three port control panel ) ( it should be ce and iso 13485 certified ) fully automatic three port control panel for oxygen , emergency manifold line regulator emergency manifold line regulator supply, installation, testing and commissioning of emergency manifold line regulator i n p u t p r e s s u r e 1 5 0 k g / c m 2 working pressure 4 kg / cm2 it should be ce and iso 13485 certified.oxygen input pressure 150 kg / cm2 working pressure 4 kg / cm2capacity : 1500 lpm , cylinderconnectingpipe ( pig tail ) supply, installation, testing and commissioning of cylinder connecting pipe ( pig tail ) made up of flexible ss hose with safety cord 5 / 8 inch bsp gland nut and one side 1 / 2 inch bsp internal threads having one meter length. ( oxygen 24 , n2o 10, co2 4 ) , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , medical air ( 4 bar ) outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve, supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified.42mm , isolation valve 2 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 28mm , isolation valve 3 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 22mm , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness , pipeline 4 medical grade copper pipeline ( in mtrs. ) as per en 13348, 28 mm ( od ) x 0.9 mm thickness , pipeline 5 medical grade copper pipeline ( in mtrs. ) as per en 13348, 42 mm ( od ) x 1.2 mm thickness , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 2268 mm x ( w ) 922 mm x ( h ) 610 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , paediatric bed with mattress paediatric bed of overall sizes in mm: 1500 ( l ) x 850 ( w ) x 1210 ( h ) flat single section bed with grille frame on 4 sides.suitable for children up to 12 years.drop down grill frame on both sides for protection of the patient.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral white , bed side locker type i over all dimension :402mmlx422mm wx840mm ht .locker should have one cabinet and one drawer unit .both provided with cam lock .there should be gap between drawer and unit to keep general items for frequesnt use castors are provided for easy handling .drawer made up of crca sheet 1 mm thick and has ball slide for easy operation .top ss 304 sheet 0.8 mm thick castors 50 mmdia , hamdle abs ..powder coating of epoxy polyester , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , strecher on trolley type i 2005mm ( l ) x666mm ( w ) x827mm ( h ) .the trolley should be made of 31.75 and 25.4 mm dia 1.6 mm thick erw tube.holder for stretcher should be made up of mild steel.castor should be of 200 mm dia , diagonal locking castor.stretcher should be made up oferw tubeof dia 25.4 mm and thickness 1.6 mm.top sheet should be made of crca sheetof thickness 1.2 mm with contour shape to accommodate patient.iv pole holder should be made ofms .maximum safe work load should be 135 kg.to ensure qood quality welding co2 argonprocess should be adhered to.all metal componentsshould be pre treated with zinc phosphating in 9 tank porcess and then powder coated with anti microbialepoxy polyster powder coating.goods should be supplied in knocked down construction to reduce carbon emission. performance test :proof loading test , cycle tests , impact test, salt spray test, castor break test, the manufacturer should compilant with iso 9001, 14001, 13485, ohsas 1800 and ce certification. , doctor desk type x s / f / f executive table main desk should be of dimesion : 1350w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. side panels : ( black ) made form 18mm thick plt with pvc lipping.modesty panel : made form 18mm thick plt with pvc lipping. bigger upper panel in black and smaller lower panel in white cedar. made from 18mm thick plt with pvc lipping. mobile pedestal : one box and one filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , chair type iii s / f / f executive chair1 ) seat / back assembly: the seat and back are made up of 1.2 cm. thick hot pressed plywood, upholstered withfabric upholstery covers and moulded polyurethane foam. the back foam is designed with contoured lumbar support for extra comfort. the seat has extra thick foam on front edge to give comfort to popliteal area.high back size : 47.5 cm ( w ) x 69.5 cm ( h ) seat size : 47.0 cm. ( w ) x 48.0 cm. ( d ) 2 ) polyurethane foam: the polyurethane foam is moulded with density = 45 + / 2 kg / m 3and hardness = 20 + / 2at 25% compression. 3 ) armrests: the one piece armrests are injection moulded from black co polymer polypropylene. 4 ) center tilt synchro mechanism : the mechanism is designed with the following features:• 360 revolving type. • upright position locking. • tilt tension adjustment.• seat / back tilting ratio of 1:3 ( 60 seat tilt / 180 back tilt ) . 5 ) pneumatic height adjustment : the pneumatic height adjustment has anadjustment stroke of 12.0 cm. 6 ) telescopic bellow assembly : the bellow is 3 piece telescopic type and injection moulded in black polypropylene. 7 ) pedestal assembly : . , staff / visitor chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck .3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement.mx load bearing capacity should be 10 kg. , hospital curtain tracks & i.v. tree system supply installation testing & commissioning of cubical tracks system made of powder coated aluminium alloy, stain free polyster fabric , water repellent curtains , smooth movement , non sticking runnner with stainless steel hooks made from mirror finish stainless steel , adjustable height with all accessories. total quantity : 1...

Health And Family Welfare Department - Bihar

30458798 bids are invited for pile boring, providing and installation bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using direct mud circulation ( dmc ) or bailer and chisel technique by tripod and mechanical winch machine all complete, including removal of excavated earth with all its lifts and leads ( length of pile for payment shall be measured up to bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , upvc door providing and fixing of factory made upvc white colour casement door, upvc multichambered extruted frame, sash and mullion profile. frame duly reinforced with 1.2mm gi section box tpe chamber and sash with 1.5mm thick gi section ( ± 0.2mm ) based on wind load calculations ( shape and size according to upvc profiles ) , appropiate dimentions of upvc extruded glazing bead, epdm gasket ( k / o type ) , seperate drainage system, ss34 grade friction hinges 2d / 3d plate hinges, zinc alloy ( white powder coated ) casement handle, gi fastener 8x100 mm size for fixing frame to finish wall, plastic packer and caps and necessary steel screws etc.profile of frame and sash shall be metered cut and fusion welded at all corners, mullion shall be also fusion welded / joined mechanically including drilling of holes for fixing hardware and drainage of water etc. after fixing of frames , gap between frame and adjascent wall shall be filled with pu foaam / backer rod required size and the approved quantity. after that sealed with weather proof silicon sealant at both side, all complete as per approved drawing and direction of eic , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 1 providing and laying vitrified floor tiles in different sizes ( thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including grouting the joints with white cement and matching pigments etc., complete. size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge :flamed finish granite stone slab jet black, cherry red, elitebrown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item ( galvanised@80gsm ) 50 mm long 8mmouter diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’ , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975. the wind load shall be as per provisions of is 875 ( part iii ) . lgsfs frame shall be designed as per is: 801 using commercially available software such as frame cad pro 11.7 / staad pro v8i / architekv2.5.16 / revit architecture 2011 or equivalent. proper usage of connection accessories like heavy duty tension ties, light duty hold ons, twist straps ( to connect truss with wall frames ) , strong tie, tie rod, h brackets, boxing sections, l shaped angles for better structural stability. the framing section shall be cold form c type having minimum web depth 89 mm x 39mm flange x 11mm lip in required length as per structural design requirement duly punched with dimple / slot at required locations as per approved drawings. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm and. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , face panel providing and fixing in all exterior face panels breathable vapour barrier underneath the cementfiber board as per national building code 2009 complete as per direction of engineer in charge. , lap siding supplying and installation of moisture resistant / fire resistantlap siding 8 mm thick and width as per standard sizes made ofiber cement board with embossed decorative finish to give pleasing exterior fixed horizontally with staggered joints including minimum over lapof 32 mm external cement fibre boardconforming to is 14862:2000 offixed with self drilling / taping screws / fastners of approved make. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1 new work ( two or more coats ) over and including water tinnable priming coat with cement primer , ex. paint finishing walls with textured exterior paint of required shade : new work ( two or more coats applied @ 3.28 ltr / 10 sqm ) over and including priming coat of exterior primer applied @ 2.20kg / 10 sqm sqm , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel 1 steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , road providing and laying c.c. pavement of mix m 25 with ready mixed concrete from batching plant. the ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc.complete as per specifications and directions of engineer in charge. ( the panel shuttering work shall be paid for separately ) . ( note: cement content considered in this item is @ 330 kg / cum. excess / less cement used as per design mix is payable / recoverableseparately ) . , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 1 providing & fixing stone slab table rubbed, edges rounded and polished of size 75 x 50cm deep and 1.8 cm thick fixed in urinal patitions by cutting chase of appropriate width with chase cutter and embedding the stone in chase with epoxy grout or with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregste 6mm nominal size ) as per engineer in charge and finished smooth white agaria marble stone , phe 2 providing and fixing salem stainless steel a isi 304 ( 18 / 8 ) kitchen sink as per is: 13983 with ci brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required. kitchen sink with drain board510x1040mm bowl depth 200mm. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing:rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixturescomplete, including cutting and making good the walls andlevel whitep.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings andfloors wherever required :white vitreous china orissa pattern w.c. pan of size580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 9 providing and fixing cp brass 32mm size bottle trap of approved quality & make and as per the direction of engineer in charge.. ( sink & urinal ) , phe 10 providing & fixingptmt towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealedfittings arrangement of approved quality and colour weighing not less than 88 gms , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size 660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 15 providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water ( 250 ml & 500 ml consumption ) , having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of engineer in charge.. , phe 16 providing & fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. , phe 17 providing and fixing white vitreous china laboratory sink with c.i. brackets, c.p. brass chain with rubber plug, 40 mm c.p brass waste and 40mm c.p. brass trap with necessary c.p. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required :size 600x450x200 mm , phe 18 providing and fixing cp brass single lever telephonic wall mixer of quality & make as approved by engineer in charge . a ) 15 mm nominal dia. , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 21 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 24 two or more coats on new work over an under coat ofsuitable shade with ordinary paint of approved brand andmanufacturetwo more coast on new work , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm.clear depth and 250mm apron including cost of e / w. involved with 75mmcement concrete ( 1:4:8 ) over one brick designation 100 a flat soling inproper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 8 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia. exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 11 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 450 mm dia rcc pipe , ex. phe 12 inside size 120x90 cm and 90 cm deep including c.i. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg ) :with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , ex. phe 13 providing and fixing square mouth sw gully trap grade ‘a’ complete ci grating brick masonry chamber with bricks of class designation 75 and water tight ci cover with frame of 300 x 300 mm size ( inside ) the weight of cover to be not less than 13.00 kg and frame to be not less than 5 kg. as per standard design. ( cover min. 4.5 kg & frame min.2.7 kg ) 180x150 mm size p type with fps bricks , ex. phe 14 constructing masonry chamber 30x30x50 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement:4 coarce sand ) for stop cock complete with c.i. surface box 100x100x75mm ( inside ) with locking arrangement and rcc top slab 1:2:4 mix ( 1 cement : 2 corase sand: 4 graded stonr aggregate 20mm nominal size ) necessary excavation foundation concret 1:5:10 ( 1 cement:5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortor 1:3 ( 1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design. , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , ex. phe 16 structual steel work welded in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. , ex. phe 17 making connection of gi distribution branch with gi main of 50 80mm nominal bore by providing and fixing tee, including cutting and threading the pipe etc. complete. , rain water harvesting 1 boring / drilling bore well of required dia for casing / strainer pipe, bysuitable method prescribed in is:2800 ( part i ) , including collecting sample from different strata , preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90m depth below ground level.300 mm dia , rain water harvesting 2 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150mm nominal size dia , rain water harvesting 3 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well screen ( rms ) pipes with ribs, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150 mm nominal size dia , rain water harvesting 4 supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 5 supplying, filling, spreading & levelling gravel of size range 5mm to 10mm, in recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 7 providing and fixing bail plug / bottom plug of required dia to the bottom of pipe assembly of tube well as per is:2800 ( part i ) . 100 mm dia , rain water harvesting 8 making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and s.w. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , rain water harvesting 9 constructing soak pit 1.20x1.20x1.20 m filled with brickbats including s.w. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , tubewell 1 boring / drilling bore well of required dia for casing / strainer pipe, bysuitable method prescribed in is:2800 ( part i ) , including collecting sample from different strata , preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90m depth below ground level.300 mm dia , tubewell 2 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150mm nominal size dia , tubewell 3 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.100mm nominal size dia , tubewell 4 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well screen ( rms ) pipes with ribs, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.100 mm nominal size dia , tubewell 5 supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , tubewell 6 providing and fixing bail plug / bottom plug of required dia to the bottom of pipe assembly of tube well as per is:2800 ( part i ) . 100 mm dia , submersible pump 35m deep boring with casing and pipe. supply of pipe etc supplying & installation of suitable 2hp submersible pump b.s or k.s.bor equivalent make with finolex cable 1x3x2.5 squmm ( upto 50mtr ) withflexible conduit 25mm dia, electrical out door pannel with required electrical fitting such as mcb of 0 25amp ( havell or indocopp or mds make ) , volt & ampere meter ( ae make ) , single phase preventer ( minilac or vsp 1 make ) starter ( l&t or bch make ) etc of approved make, 40mm hdpe pipe ( 25 mtr ) and all accessories complete as per requirement of site. , water purifier and cooler 1 fitting and fixing single faucet storage type water cooler ( size 461 mm wide x 582 mm deep x 1217 mm height, weight 46 kg ) fully stainless body having storage capacity of 40 ltrs, cooling capacity of 40 ltrs. / hr. with hermetic type compressor, gas cooled motor equipped with over load protector, condensor for propeller type, thermostat autometically controlled temperature, refrigerent r 22, 230 volt, single phase 50 hertz, maximum current 2.3 amp including plug top and electrical lead wire connection upto 3 metres from the cooler, water inlet and drain out connections complete in all respects of voltas model no 40 / 40 tushar pss type or similar type of approved make. , water purifier and cooler 2 fitting and fixing water purifier for drinking purpose of capacity 6 litres / min, 5 purification system with reverse osmosis system with ultra ventilated membrane, tds500 to 2000 mgl / ppm, auto shut off with microswitch float manual flush facility, tds reduction 90% having automatic backwash system with filteration unit along with all accessories including plug top and electrical lead wire connection upto 3 metres from the purifier, water inlet and drain out connections complete in all respects similar to aquaguard or similar approved make ( model aquasure elegant ro water purifier of size width 360 mm x height 430 mm x depth 235 mm and weight 8.5 kg ) . , fire extinguisher 1 providing and fixing carbon di oxide type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. capacity 4.5 kg. , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 6.0 kg. , electrical 1 wiring for light point / fan point / exhaust fan point / call bellpoint with 1.5 sq.mm frls pvc insulated copper conductorsingle core cable in surface / recessed steel conduit, withmodular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. group c , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , pvc conduit 1 supplying and fixing of following sizes of medium class 20mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , pvc conduit 2 supplying and fixing of following sizes of medium class 32mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , pvc conduit 3 supplying and fixing of following sizes of medium class 50mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , electrical 4 wiring for light / power plug with 2x4 sq. mm frls pvcinsulated copper conductor single core cable in surface / recessed conduit alongwith 1 no. 4 sq. mm frls pvcinsulated copper conductor single core cable for loop earthingas required. , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 4 x 6 sq. mm + 2 x 6 sq. mm earth wire , wiring frls pvc insulated copper conductor 4 4 x 10 sq. mm + 2 x 6 sq. mm earth wire , wiring frls pvc insulated copper conductor 5 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 1 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 3 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 4 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 2 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 3 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 4 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 5 telephone socket outlet , s / f modular switch / socket on the existing modular plate 6 tv antenna socket outlet , s / f modular switch / socket on the existing modular plate 7 bell push , electrical 5 supplying & fixing suitable size gi box wih modular plate and cover in front on surface or in recess including providing and fixing 25 a modular socket outlet and 25 a modular sp mcb, “c” curve including connections, painting etc. as required. ( for ac / geyser ) , electrical 6 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface / recessed steel / pvc conduit as required. , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 11 supplying and fixing 20 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. , electrical 12 supplying and fixing 30 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , electrical 14 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 12 way , double door , electrical 15 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 16 way, double door , electrical 16 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 6 way ( 4 + 18 ) , double door , electrical 17 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way ( 4 + 24 ) , double door , electrical 18 supplying and fixing of following ways surface / recess mounting, vertical type, 415 v, tpn mcb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 a tinned copper bus bar, common neutral link, earth bar, din bar for mounting mcbs ( but without mcbs and incomer ) as required . ( note : vertical type mcb tpdb is normally usedwhere 3 phase outlets are required. ) 4 way ( 4 + 12 ) , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 63a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 100a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , l / f pvc sheathed / xlpe power cable in trench laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 95 sq. mm and upto 185 sq. mm , l / f pvc sheathed / xlpe power cable in trench 1 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 185 sq. mm and upto 400 sq. mm , l / f pvc sheathed / xlpe power cable over cable tray upto 35 sq. mm ( clamped with 1mm thick saddle ) , l / f pvc sheathed / xlpe power cable over cable tray 2 above 35 sq. mm and upto 95 sq. mm ( clamped with 25x3mm ms flat clamp ) , l / f pvc sheathed / xlpe power cable over cable tray 3 above 95 sq. mm and upto 185 sq. mm ( clamped with 25 / 40x3mm ms flat clamp ) , l / f pvc sheathed / xlpe power cable over cable tray 4 above 185 sq. mm and upto 400 sq. mm ( clamped with 40x3mm ms flat clamp ) , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 3.5c x 300 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 1 3.5c x 240 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 2 3.5c x 120 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 3 3.5c x 95 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 4 3.5c x 50 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 5 4c x 35 sqmm aluminium conductor cable a2xfy , cable tray supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 100 mm width x 50 mm depth x 1.6 mm thickness , cable tray 1 supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 300 mm width x 50 mm depth x 1.6 mm thickness , cable tray 2 supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 600 mm width x 62.5 mm depth x 2.0 mm thickness , cable tray “bends” supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.100 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 1 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.150 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 2 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.300 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 3 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.450 mm width x 50 mm depth x 2 mm thickness , cable tray “bends” 4 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.600 mm width x 62.5 mm depth x 2.0 mm thickness , mv cable supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 300 sqmm, aluminium conductor cable a2xfy , mv cable 1 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 240 sqmm, aluminium conductor cable a2xfy , mv cable 2 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 120 sqmm, aluminium conductor cable a2xfy , mv cable 3 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 95 sqmm, aluminium conductor cable a2xfy , earthing earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 1 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. , earthing 2 earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. , earthing 3 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 4 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , earthing 5 providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required. , earthing 6 providing and fixing earth bus of 50 mm x 5 mm copper strip on surface for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 4 supplying and fixing recess mounted 12 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 6 supply, installation, testing and commissioning of 400 mm sweep, 65w, blade material aluminium blades , speed & oscillation 3 speed, pull cord for speed and oscillation.air delivery minimum 72 m³ / min, speed minimun 1350 revolution per minute.suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , fiting & fixtures 8 supplying installation testing & commissioning ofb22 based 9w led 3 star bulb with 850 lumen, 6k color temperature including holder. , fiting & fixtures 9 supplying installation testing & commissioning of black painted extruded aluminium housing. green / red led’s mounted inside the housing. laser engraved signage matter on single / double acrylic sheet fixed on one side suitable for wall / ceiling / suspension type single / double sided display. in double sided version black paper is inserted. ni cd battery back up to 2 hrs. ( charged up to 8 10 hrs ) .mounting strings provided for pendent mounting operating voltage 150 280v ac ambient operating temperature. – 0 to 450c ingress protection – ip42.including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required.   220208 besl 03 led ssd wbb green 240 3 8wor220209 besl 03 led ssd wbb red 240 3 8wor220210 besl 03 led dsd wbb green 240 3 8wor220211 besl 03 led dsd wbb red 240 3 8w , fiting & fixtures 10 supply, installation, testing & erecting of ip66 bulkhead surface type lighting fixture 10w made up of pressure die cast aluminium housing and polyster powder coated die cast aluminium with high quality polycarbonate diffuser in opal finish for glare free light distribution.high efficiency long life led module with smd led package mounted on mcpcb with lumen efficacy of >95 lm / w with system lumen 950. powered by integral electronic led driver with apfc with low thd output short / open circuit protection. cct 5700, cri>80, system efficacy>90lm / w, thd<15%, pf>.95, ip66, ik 10, life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz.including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. cat ref: havells : hexaft10wled857ssymbopc or approved equivalent. , civil & misc works1 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. , civil & misc works2 providing and fixing h.t. danger notice plate of 250 mm x 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. , civil & misc works3 supplying and making cable route marker with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm x 60 cm at the bottom and 50 cm x 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. , civil & misc works4 supplying and fixing cable route marker with 10 cm x 10 cm x 5 mm thick g.i. plate with inscription there on, bolted / welded to 35 mm x 35 mm x 6 mm angle iron, 60 cm long and fixing the same in ground as required. , civil & misc works5 providing & fixing in position 1000 mm wide , electrical insulating rubber mats as per is 15652:2006, 2 mm thick, suitable up to 1.1 kv , fire retardant, no effect of acids, alkalis and transformer oils, moisture proof, high tensile strengthandtexture finish / cloth impression ( anti slip , marking on top ) , civil & misc works6 supply & fixing shock treatment chart duly mounted on a wooden frame with 5 mm thick glass as required ( approx front area 1.20 sq metre ) , 40 kvaups supplying, installation, testing and commissioningof online double conversion fully microprocessor based , indoor type, compact ups system of following rating with igbt based pwm technology to achieve thd < 3% and input power factor of greater than 0.95 at 50% loading, suitable for three phase ac input voltage 380 v to 440 v, 50 hz +3% / 3 % and three phase ac output voltage 415 ± 1% volts & frequency 50 ± 0.5 hz , inbuilt isolation transformer, necessary vrla batteries of suitable size having 30 minutes back up time , mounting rack including and suitable size connecting cable ( for ups to battery and battery to battery ) , static and maintenance bypass switch, snmp card for rs232 / ethernet ip computability for operation and monitoring etc. with all components as mentioned , specifications, complete as required.note : concerning vendor needs to furnish the battery sizing calculations at the time of ga approval and battery size has to be as per the approved ga drawing. , external lighting 1 supply and erection of 4 metre height hot dipgalvanized octagonal street light pole with followingarm with top dia 70 mm and bottom dia a / f 130 mm, made of 3 mm thick sheet along with base plate of size220 x 220 x 12 mm , small door opening for junctionbox mounting with mcb & connector, cement concreteof 1:3:6 including excavation, refilling and suitable sizefoundation bolts with template and all complete jobasrequired. ( but without pole collar ) single arm , external lighting 2 supplying and fixing 40 / 45 watt led type street lightwith die cast aluminium housing for ingress protectionof ip65 and complete with all accessories etc, onpole / building including connection with fr pvcinsulated copper conductor cable and earthing thebody etc. as required. , ip based cctv system 1 sitc of 2 megapixel @ 25fps, h.265 ip bullet camera, 1 / 2.9 cmos with 2.8~12mm varifocal lens, 0 lux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 2 sitc of 2 megapixel @ 25fps, h.265 ip dome camera, 1 / 2.9 cmos with 3.6 fixed mm 0 lux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 3 sitc of 2 megapixel @ 25fps, ptz camera h.265 ip dome camera, 1 / 2.9 cmos with 2.6 fixed lenslux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 4 sitc of 32ch 4k ivr , h.265 / h.264 • 1080p real time • 4k display • dual lan • 8x hdd • raid •web plugin free h.265 / h.264 compression technology 4k display for clear monitoring up to 1080p 16ch decoding ability smart search ii smart vca event searchsupport raid 0, 1, 5 supported to prevent from recording data loss browsers supported: ie , smart functions : target count, electric fence, face detection, humaniod detection, retrograde detection, leave position detectio output, local & network backup etc. complete as required. , cctv 5 sitc of harddiskdrive8tb, 24 / 7surveillance category only complete etc as required.etc.all complete , cctv 6 sitc of 55 led narrow bazel for monitoring for nvr server etc. all complete. , cctv 7 sitc of rj 45 outlets near the cameras etc. all complete. etc. all complete. , cctv 8 sitc of cat 6 patch cords 1 meter high quality four pair twisted stranded cable terminated with rj45 modular plugs at both the ends. , signage 1 providing & fixing of building direction signage mounted on pole, with pole of 100x100mm shs ( square hollow section ) of height of 5600mm, and sign size of 900x1050, sign made of aluminiu c section of 60mm with internal framing to support the frame in ms tubes hollow section, frame work duly painted with anti rust coatings, with facia of 3mm thick exterior grade aluminium composite panel, cladded with uv cured digital printed retroreflective sheet of 3m make, and back panel of 3mm exterior grade acp, all pipes to be painted in approved color. cost shall includecost towards installation, including excuvation and filling up with specified pcc and fixing of foundation bolts as specified, also it shall include the designing charges.all complete as per direction by engineer in charge. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , 2 tr air conditioning 1 split ac ( inverter model ) : supply, installation, testing, commissioning of split type wall mounted air conditioning units of following capacity including inddor, outdoor unit fitted with inverter based rotary compressor fitted with rotary compressor, copper condensor and first charge refrigent r410a / eco friendly green gas only, all complete including all electrical connections to the electrical power supply system of the building, includingbut not limited to supply of all electrical plugs, etc., as necessary, lengthening of all electrical wires of ac units ( both indoor and outdoor ) , drain pipe andincluding suitable voltage stabilisers, etc. so as to place them in a concealed manner in the desired position. the copper pipes and electrical cables shall be concealed in approved manner and neatly run in straight lines in a workman like manner with proper supports. complete supply and installation of split2 tr star rating 3 star , refrigerant piping copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 25 mm od, wall thickness >= 1.2 mm ( insulation 19 mm thick ) , refrigerant piping 1 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 19.1 mm od, wall thickness >= 1.0 mm ( insulation 13 mm thick ) , refrigerant piping 2 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 15.9 mm od, wall thickness >= 0.8 mm ( insulation 13 mm thick ) , refrigerant piping 3 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 9.5 mm od, wall thickness >= 0.8 mm ( insulation 13 mm thick ) , drain piping providing and fixing of cpvc 6 kg / cm2 drainpiping complete with fittings, supports, 6 mm thick closed cell elastomeric insulation as per specifications and drawings. 20 mm , drain piping 1 providing and fixing of cpvc 6 kg / cm2 drainpiping complete with fittings, supports, 6 mm thick closed cell elastomeric insulation as per specifications and drawings. 32 mm , main oxygen manifold supply, installation, testing and commissioning of following gas manifold system ( excluding cylinders ) . the manifold is configured for designed numbers of cylinders and is suitable to withstand a pressure of 145 kg / cm2, along withhigh pressure copper annealed tail pipes with end brass adapter suitable for cylinders and manifold. top frame comprising of high pressure copper pipes of size 1 / 2” nb x 15swg with high pressure brass fittings made of high tensile brass and connections through nonreturn valves, the design of middle and bottomframes is provided to fit both round and flat bottom cylinders safely. the manifold is tested ( hydraulically ) at 3500 psig. ( it should be ce and iso 13485 certified ) mani fold oxygen manifold 6 + 6 cylinder banks complete with nrv, middle frame, bottom frame with ce marked, , emergency manifold emergency oxygen manifold 01 + 01 cylinder emergency manifold with complete regulator, nrv, middle frame & bottom frame, , control panelfor oxygen fully automatic three port control panel for oxygen supply, installation, testing and commissioning of automatic manifold control panel would provide a duty or standby gas supply from two cylinder banks with automaticchangeover the manifold indicates local status and has a remote indicator facility. automaticmanifold control panel would be designed to supply the mgps with a constant pressure supply via a control panel form two equal banks of cylinders and the changeover from the ‘duty’ to the ‘standby’ bank of cylinders would beautomatic. automatic changeover from the duty to the standby bank would occur at a cylinder pressure that will ensure the maximum usage of the contents of the duty bank. the changeover unit would be provided with monitoring todetect and display: duty bank operating, duty bank empty, standby bank operating, and standby bank below 10 % when the duty bank is empty, reserve bank low, pipeline pressure fault. there would be facility to connect liquidoxygen supply ( i.e. three port control panel ) ( it should be ce and iso 13485 certified ) fully automatic three port control panel for oxygen , emergency manifold line regulator emergency manifold line regulator supply, installation, testing and commissioning of emergency manifold line regulator i n p u t p r e s s u r e 1 5 0 k g / c m 2 working pressure 4 kg / cm2 it should be ce and iso 13485 certified.oxygen input pressure 150 kg / cm2 working pressure 4 kg / cm2capacity : 1500 lpm , cylinderconnectingpipe ( pig tail ) supply, installation, testing and commissioning of cylinder connecting pipe ( pig tail ) made up of flexible ss hose with safety cord 5 / 8 inch bsp gland nut and one side 1 / 2 inch bsp internal threads having one meter length. ( oxygen 24 , n2o 10, co2 4 ) , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , medical air ( 4 bar ) outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve, supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified.42mm , isolation valve 2 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 28mm , isolation valve 3 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 22mm , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness , pipeline 4 medical grade copper pipeline ( in mtrs. ) as per en 13348, 28 mm ( od ) x 0.9 mm thickness , pipeline 5 medical grade copper pipeline ( in mtrs. ) as per en 13348, 42 mm ( od ) x 1.2 mm thickness , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 2268 mm x ( w ) 922 mm x ( h ) 610 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , paediatric bed with mattress paediatric bed of overall sizes in mm: 1500 ( l ) x 850 ( w ) x 1210 ( h ) flat single section bed with grille frame on 4 sides.suitable for children up to 12 years.drop down grill frame on both sides for protection of the patient.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral white , bed side locker type i over all dimension :402mmlx422mm wx840mm ht .locker should have one cabinet and one drawer unit .both provided with cam lock .there should be gap between drawer and unit to keep general items for frequesnt use castors are provided for easy handling .drawer made up of crca sheet 1 mm thick and has ball slide for easy operation .top ss 304 sheet 0.8 mm thick castors 50 mmdia , hamdle abs ..powder coating of epoxy polyester , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , strecher on trolley type i 2005mm ( l ) x666mm ( w ) x827mm ( h ) .the trolley should be made of 31.75 and 25.4 mm dia 1.6 mm thick erw tube.holder for stretcher should be made up of mild steel.castor should be of 200 mm dia , diagonal locking castor.stretcher should be made up oferw tubeof dia 25.4 mm and thickness 1.6 mm.top sheet should be made of crca sheetof thickness 1.2 mm with contour shape to accommodate patient.iv pole holder should be made ofms .maximum safe work load should be 135 kg.to ensure qood quality welding co2 argonprocess should be adhered to.all metal componentsshould be pre treated with zinc phosphating in 9 tank porcess and then powder coated with anti microbialepoxy polyster powder coating.goods should be supplied in knocked down construction to reduce carbon emission. performance test :proof loading test , cycle tests , impact test, salt spray test, castor break test, the manufacturer should compilant with iso 9001, 14001, 13485, ohsas 1800 and ce certification. , doctor desk type x s / f / f executive table main desk should be of dimesion : 1350w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. side panels : ( black ) made form 18mm thick plt with pvc lipping.modesty panel : made form 18mm thick plt with pvc lipping. bigger upper panel in black and smaller lower panel in white cedar. made from 18mm thick plt with pvc lipping. mobile pedestal : one box and one filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , chair type iii s / f / f executive chair1 ) seat / back assembly: the seat and back are made up of 1.2 cm. thick hot pressed plywood, upholstered withfabric upholstery covers and moulded polyurethane foam. the back foam is designed with contoured lumbar support for extra comfort. the seat has extra thick foam on front edge to give comfort to popliteal area.high back size : 47.5 cm ( w ) x 69.5 cm ( h ) seat size : 47.0 cm. ( w ) x 48.0 cm. ( d ) 2 ) polyurethane foam: the polyurethane foam is moulded with density = 45 + / 2 kg / m 3and hardness = 20 + / 2at 25% compression. 3 ) armrests: the one piece armrests are injection moulded from black co polymer polypropylene. 4 ) center tilt synchro mechanism : the mechanism is designed with the following features:• 360 revolving type. • upright position locking. • tilt tension adjustment.• seat / back tilting ratio of 1:3 ( 60 seat tilt / 180 back tilt ) . 5 ) pneumatic height adjustment : the pneumatic height adjustment has anadjustment stroke of 12.0 cm. 6 ) telescopic bellow assembly : the bellow is 3 piece telescopic type and injection moulded in black polypropylene. 7 ) pedestal assembly : . , staff / visitor chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck .3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement.mx load bearing capacity should be 10 kg. , hospital curtain tracks & i.v. tree system supply installation testing & commissioning of cubical tracks system made of powder coated aluminium alloy, stain free polyster fabric , water repellent curtains , smooth movement , non sticking runnner with stainless steel hooks made from mirror finish stainless steel , adjustable height with all accessories. total quantity : 1...

Health And Family Welfare Department - Bihar

30458765 bids are invited for pile boring, providing and installation bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using direct mud circulation ( dmc ) or bailer and chisel technique by tripod and mechanical winch machine all complete, including removal of excavated earth with all its lifts and leads ( length of pile for payment shall be measured up to bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , upvc door providing and fixing of factory made upvc white colour casement door, upvc multichambered extruted frame, sash and mullion profile. frame duly reinforced with 1.2mm gi section box tpe chamber and sash with 1.5mm thick gi section ( ± 0.2mm ) based on wind load calculations ( shape and size according to upvc profiles ) , appropiate dimentions of upvc extruded glazing bead, epdm gasket ( k / o type ) , seperate drainage system, ss34 grade friction hinges 2d / 3d plate hinges, zinc alloy ( white powder coated ) casement handle, gi fastener 8x100 mm size for fixing frame to finish wall, plastic packer and caps and necessary steel screws etc.profile of frame and sash shall be metered cut and fusion welded at all corners, mullion shall be also fusion welded / joined mechanically including drilling of holes for fixing hardware and drainage of water etc. after fixing of frames , gap between frame and adjascent wall shall be filled with pu foaam / backer rod required size and the approved quantity. after that sealed with weather proof silicon sealant at both side, all complete as per approved drawing and direction of eic , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 1 providing and laying vitrified floor tiles in different sizes ( thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including grouting the joints with white cement and matching pigments etc., complete. size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge :flamed finish granite stone slab jet black, cherry red, elitebrown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item ( galvanised@80gsm ) 50 mm long 8mmouter diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’ , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975. the wind load shall be as per provisions of is 875 ( part iii ) . lgsfs frame shall be designed as per is: 801 using commercially available software such as frame cad pro 11.7 / staad pro v8i / architekv2.5.16 / revit architecture 2011 or equivalent. proper usage of connection accessories like heavy duty tension ties, light duty hold ons, twist straps ( to connect truss with wall frames ) , strong tie, tie rod, h brackets, boxing sections, l shaped angles for better structural stability. the framing section shall be cold form c type having minimum web depth 89 mm x 39mm flange x 11mm lip in required length as per structural design requirement duly punched with dimple / slot at required locations as per approved drawings. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm and. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , face panel providing and fixing in all exterior face panels breathable vapour barrier underneath the cementfiber board as per national building code 2009 complete as per direction of engineer in charge. , lap siding supplying and installation of moisture resistant / fire resistantlap siding 8 mm thick and width as per standard sizes made ofiber cement board with embossed decorative finish to give pleasing exterior fixed horizontally with staggered joints including minimum over lapof 32 mm external cement fibre boardconforming to is 14862:2000 offixed with self drilling / taping screws / fastners of approved make. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1 new work ( two or more coats ) over and including water tinnable priming coat with cement primer , ex. paint finishing walls with textured exterior paint of required shade : new work ( two or more coats applied @ 3.28 ltr / 10 sqm ) over and including priming coat of exterior primer applied @ 2.20kg / 10 sqm sqm , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel 1 steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , road providing and laying c.c. pavement of mix m 25 with ready mixed concrete from batching plant. the ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc.complete as per specifications and directions of engineer in charge. ( the panel shuttering work shall be paid for separately ) . ( note: cement content considered in this item is @ 330 kg / cum. excess / less cement used as per design mix is payable / recoverableseparately ) . , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 1 providing & fixing stone slab table rubbed, edges rounded and polished of size 75 x 50cm deep and 1.8 cm thick fixed in urinal patitions by cutting chase of appropriate width with chase cutter and embedding the stone in chase with epoxy grout or with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregste 6mm nominal size ) as per engineer in charge and finished smooth white agaria marble stone , phe 2 providing and fixing salem stainless steel a isi 304 ( 18 / 8 ) kitchen sink as per is: 13983 with ci brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required. kitchen sink with drain board510x1040mm bowl depth 200mm. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing:rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixturescomplete, including cutting and making good the walls andlevel whitep.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings andfloors wherever required :white vitreous china orissa pattern w.c. pan of size580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 9 providing and fixing cp brass 32mm size bottle trap of approved quality & make and as per the direction of engineer in charge.. ( sink & urinal ) , phe 10 providing & fixingptmt towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealedfittings arrangement of approved quality and colour weighing not less than 88 gms , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size 660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 15 providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water ( 250 ml & 500 ml consumption ) , having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of engineer in charge.. , phe 16 providing & fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. , phe 17 providing and fixing white vitreous china laboratory sink with c.i. brackets, c.p. brass chain with rubber plug, 40 mm c.p brass waste and 40mm c.p. brass trap with necessary c.p. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required :size 600x450x200 mm , phe 18 providing and fixing cp brass single lever telephonic wall mixer of quality & make as approved by engineer in charge . a ) 15 mm nominal dia. , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 21 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 24 two or more coats on new work over an under coat ofsuitable shade with ordinary paint of approved brand andmanufacturetwo more coast on new work , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm.clear depth and 250mm apron including cost of e / w. involved with 75mmcement concrete ( 1:4:8 ) over one brick designation 100 a flat soling inproper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 8 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia. exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 11 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 450 mm dia rcc pipe , ex. phe 12 inside size 120x90 cm and 90 cm deep including c.i. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg ) :with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , ex. phe 13 providing and fixing square mouth sw gully trap grade ‘a’ complete ci grating brick masonry chamber with bricks of class designation 75 and water tight ci cover with frame of 300 x 300 mm size ( inside ) the weight of cover to be not less than 13.00 kg and frame to be not less than 5 kg. as per standard design. ( cover min. 4.5 kg & frame min.2.7 kg ) 180x150 mm size p type with fps bricks , ex. phe 14 constructing masonry chamber 30x30x50 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement:4 coarce sand ) for stop cock complete with c.i. surface box 100x100x75mm ( inside ) with locking arrangement and rcc top slab 1:2:4 mix ( 1 cement : 2 corase sand: 4 graded stonr aggregate 20mm nominal size ) necessary excavation foundation concret 1:5:10 ( 1 cement:5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortor 1:3 ( 1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design. , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , ex. phe 16 structual steel work welded in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. , ex. phe 17 making connection of gi distribution branch with gi main of 50 80mm nominal bore by providing and fixing tee, including cutting and threading the pipe etc. complete. , rain water harvesting 1 boring / drilling bore well of required dia for casing / strainer pipe, bysuitable method prescribed in is:2800 ( part i ) , including collecting sample from different strata , preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90m depth below ground level.300 mm dia , rain water harvesting 2 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150mm nominal size dia , rain water harvesting 3 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well screen ( rms ) pipes with ribs, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150 mm nominal size dia , rain water harvesting 4 supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 5 supplying, filling, spreading & levelling gravel of size range 5mm to 10mm, in recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 7 providing and fixing bail plug / bottom plug of required dia to the bottom of pipe assembly of tube well as per is:2800 ( part i ) . 100 mm dia , rain water harvesting 8 making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and s.w. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , rain water harvesting 9 constructing soak pit 1.20x1.20x1.20 m filled with brickbats including s.w. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , tubewell 1 boring / drilling bore well of required dia for casing / strainer pipe, bysuitable method prescribed in is:2800 ( part i ) , including collecting sample from different strata , preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90m depth below ground level.300 mm dia , tubewell 2 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150mm nominal size dia , tubewell 3 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.100mm nominal size dia , tubewell 4 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well screen ( rms ) pipes with ribs, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.100 mm nominal size dia , tubewell 5 supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , tubewell 6 providing and fixing bail plug / bottom plug of required dia to the bottom of pipe assembly of tube well as per is:2800 ( part i ) . 100 mm dia , submersible pump 35m deep boring with casing and pipe. supply of pipe etc supplying & installation of suitable 2hp submersible pump b.s or k.s.bor equivalent make with finolex cable 1x3x2.5 squmm ( upto 50mtr ) withflexible conduit 25mm dia, electrical out door pannel with required electrical fitting such as mcb of 0 25amp ( havell or indocopp or mds make ) , volt & ampere meter ( ae make ) , single phase preventer ( minilac or vsp 1 make ) starter ( l&t or bch make ) etc of approved make, 40mm hdpe pipe ( 25 mtr ) and all accessories complete as per requirement of site. , water purifier and cooler fitting and fixing single faucet storage type water cooler ( size 461 mm wide x 582 mm deep x 1217 mm height, weight 46 kg ) fully stainless body having storage capacity of 40 ltrs, cooling capacity of 40 ltrs. / hr. with hermetic type compressor, gas cooled motor equipped with over load protector, condensor for propeller type, thermostat autometically controlled temperature, refrigerent r 22, 230 volt, single phase 50 hertz, maximum current 2.3 amp including plug top and electrical lead wire connection upto 3 metres from the cooler, water inlet and drain out connections complete in all respects of voltas model no 40 / 40 tushar pss type or similar type of approved make. , water purifier and cooler 1 fitting and fixing water purifier for drinking purpose of capacity 6 litres / min, 5 purification system with reverse osmosis system with ultra ventilated membrane, tds500 to 2000 mgl / ppm, auto shut off with microswitch float manual flush facility, tds reduction 90% having automatic backwash system with filteration unit along with all accessories including plug top and electrical lead wire connection upto 3 metres from the purifier, water inlet and drain out connections complete in all respects similar to aquaguard or similar approved make ( model aquasure elegant ro water purifier of size width 360 mm x height 430 mm x depth 235 mm and weight 8.5 kg ) . , fire extinguisher 1 providing and fixing carbon di oxide type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. capacity 4.5 kg. , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 6.0 kg. , electrical 1 wiring for light point / fan point / exhaust fan point / call bellpoint with 1.5 sq.mm frls pvc insulated copper conductorsingle core cable in surface / recessed steel conduit, withmodular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. group c , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , pvc conduit 1 supplying and fixing of following sizes of medium class 20mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , pvc conduit 2 supplying and fixing of following sizes of medium class 32mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , pvc conduit 3 supplying and fixing of following sizes of medium class 50mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , electrical 4 wiring for light / power plug with 2x4 sq. mm frls pvcinsulated copper conductor single core cable in surface / recessed conduit alongwith 1 no. 4 sq. mm frls pvcinsulated copper conductor single core cable for loop earthingas required. , wiring frls pvc insulated copper conductor 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 1 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 2 4 x 6 sq. mm + 2 x 6 sq. mm earth wire , wiring frls pvc insulated copper conductor 3 4 x 10 sq. mm + 2 x 6 sq. mm earth wire , wiring frls pvc insulated copper conductor 4 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 1 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 3 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 4 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 1 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 2 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 3 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 4 telephone socket outlet , s / f modular switch / socket on the existing modular plate 5 tv antenna socket outlet , s / f modular switch / socket on the existing modular plate 6 bell push , electrical 5 supplying & fixing suitable size gi box wih modular plate and cover in front on surface or in recess including providing and fixing 25 a modular socket outlet and 25 a modular sp mcb, “c” curve including connections, painting etc. as required. ( for ac / geyser ) , electrical 6 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface / recessed steel / pvc conduit as required. , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 11 supplying and fixing 20 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. , electrical 12 supplying and fixing 30 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , electrical 14 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 12 way , double door , electrical 15 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 16 way, double door , electrical 16 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 6 way ( 4 + 18 ) , double door , electrical 17 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way ( 4 + 24 ) , double door , electrical 18 supplying and fixing of following ways surface / recess mounting, vertical type, 415 v, tpn mcb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 a tinned copper bus bar, common neutral link, earth bar, din bar for mounting mcbs ( but without mcbs and incomer ) as required . ( note : vertical type mcb tpdb is normally usedwhere 3 phase outlets are required. ) 4 way ( 4 + 12 ) , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 63a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 100a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , l / f pvc sheathed / xlpe power cable in trench laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 95 sq. mm and upto 185 sq. mm , l / f pvc sheathed / xlpe power cable in trench 1 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 185 sq. mm and upto 400 sq. mm , l / f pvc sheathed / xlpe power cable over cable tray 2 upto 35 sq. mm ( clamped with 1mm thick saddle ) , l / f pvc sheathed / xlpe power cable over cable tray 3 above 35 sq. mm and upto 95 sq. mm ( clamped with 25x3mm ms flat clamp ) , l / f pvc sheathed / xlpe power cable over cable tray 4 above 95 sq. mm and upto 185 sq. mm ( clamped with 25 / 40x3mm ms flat clamp ) , l / f pvc sheathed / xlpe power cable over cable tray 5 above 185 sq. mm and upto 400 sq. mm ( clamped with 40x3mm ms flat clamp ) , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 3.5c x 300 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 1 3.5c x 240 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 2 3.5c x 120 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 3 3.5c x 95 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 4 3.5c x 50 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 5 4c x 35 sqmm aluminium conductor cable a2xfy , cable tray 1 supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 100 mm width x 50 mm depth x 1.6 mm thickness , cable tray 2 supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 300 mm width x 50 mm depth x 1.6 mm thickness , cable tray 3 supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 600 mm width x 62.5 mm depth x 2.0 mm thickness , cable tray “bends” supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.100 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 1 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.150 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 2 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.300 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends”3 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.450 mm width x 50 mm depth x 2 mm thickness , cable tray “bends” 4 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.600 mm width x 62.5 mm depth x 2.0 mm thickness , mv cable supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 300 sqmm, aluminium conductor cable a2xfy , mv cable 1 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 240 sqmm, aluminium conductor cable a2xfy , mv cable 2 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 120 sqmm, aluminium conductor cable a2xfy , mv cable 3 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 95 sqmm, aluminium conductor cable a2xfy , earthing 1 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 2 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. , earthing 3 earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. , earthing 4 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 5 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , earthing 6 providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required. , earthing 7 providing and fixing earth bus of 50 mm x 5 mm copper strip on surface for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : , fiting & fixtures 4 supplying and fixing recess mounted 12 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 6 supply, installation, testing and commissioning of 400 mm sweep, 65w, blade material aluminium blades , speed & oscillation 3 speed, pull cord for speed and oscillation.air delivery minimum 72 m³ / min, speed minimun 1350 revolution per minute.suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , fiting & fixtures 8 supplying installation testing & commissioning ofb22 based 9w led 3 star bulb with 850 lumen, 6k color temperature including holder. , fiting & fixtures 9 supplying installation testing & commissioning of black painted extruded aluminium housing. green / red led’s mounted inside the housing. laser engraved signage matter on single / double acrylic sheet fixed on one side suitable for wall / ceiling / suspension type single / double sided display. in double sided version black paper is inserted. ni cd battery back up to 2 hrs. ( charged up to 8 10 hrs ) .mounting strings provided for pendent mounting operating voltage 150 280v ac ambient operating temperature. – 0 to 450c ingress protection – ip42.including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required.   220208 besl 03 led ssd wbb green 240 3 8wor220209 besl 03 led ssd wbb red 240 3 8wor220210 besl 03 led dsd wbb green 240 3 8wor220211 besl 03 led dsd wbb red 240 3 8w , fiting & fixtures 10 supply, installation, testing & erecting of ip66 bulkhead surface type lighting fixture 10w made up of pressure die cast aluminium housing and polyster powder coated die cast aluminium with high quality polycarbonate diffuser in opal finish for glare free light distribution.high efficiency long life led module with smd led package mounted on mcpcb with lumen efficacy of >95 lm / w with system lumen 950. powered by integral electronic led driver with apfc with low thd output short / open circuit protection. cct 5700, cri>80, system efficacy>90lm / w, thd<15%, pf>.95, ip66, ik 10, life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz.including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. cat ref: havells : hexaft10wled857ssymbopc or approved equivalent. , civil & misc works1 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. , civil & misc works2 providing and fixing h.t. danger notice plate of 250 mm x 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. , civil & misc works3 supplying and making cable route marker with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm x 60 cm at the bottom and 50 cm x 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. , civil & misc works4 supplying and fixing cable route marker with 10 cm x 10 cm x 5 mm thick g.i. plate with inscription there on, bolted / welded to 35 mm x 35 mm x 6 mm angle iron, 60 cm long and fixing the same in ground as required. , civil & misc works5 providing & fixing in position 1000 mm wide , electrical insulating rubber mats as per is 15652:2006, 2 mm thick, suitable up to 1.1 kv , fire retardant, no effect of acids, alkalis and transformer oils, moisture proof, high tensile strengthandtexture finish / cloth impression ( anti slip , marking on top ) , civil & misc works6 supply & fixing shock treatment chart duly mounted on a wooden frame with 5 mm thick glass as required ( approx front area 1.20 sq metre ) , 40 kvaups supplying, installation, testing and commissioningof online double conversion fully microprocessor based , indoor type, compact ups system of following rating with igbt based pwm technology to achieve thd < 3% and input power factor of greater than 0.95 at 50% loading, suitable for three phase ac input voltage 380 v to 440 v, 50 hz +3% / 3 % and three phase ac output voltage 415 ± 1% volts & frequency 50 ± 0.5 hz , inbuilt isolation transformer, necessary vrla batteries of suitable size having 30 minutes back up time , mounting rack including and suitable size connecting cable ( for ups to battery and battery to battery ) , static and maintenance bypass switch, snmp card for rs232 / ethernet ip computability for operation and monitoring etc. with all components as mentioned , specifications, complete as required.note : concerning vendor needs to furnish the battery sizing calculations at the time of ga approval and battery size has to be as per the approved ga drawing. , external lighting 1 supply and erection of 4 metre height hot dipgalvanized octagonal street light pole with followingarm with top dia 70 mm and bottom dia a / f 130 mm, made of 3 mm thick sheet along with base plate of size220 x 220 x 12 mm , small door opening for junctionbox mounting with mcb & connector, cement concreteof 1:3:6 including excavation, refilling and suitable sizefoundation bolts with template and all complete jobasrequired. ( but without pole collar ) single arm , external lighting 2 supplying and fixing 40 / 45 watt led type street lightwith die cast aluminium housing for ingress protectionof ip65 and complete with all accessories etc, onpole / building including connection with fr pvcinsulated copper conductor cable and earthing thebody etc. as required. , ip based cctv system 1 sitc of 2 megapixel @ 25fps, h.265 ip bullet camera, 1 / 2.9 cmos with 2.8~12mm varifocal lens, 0 lux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 2 sitc of 2 megapixel @ 25fps, h.265 ip dome camera, 1 / 2.9 cmos with 3.6 fixed mm 0 lux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 3 sitc of 2 megapixel @ 25fps, ptz camera h.265 ip dome camera, 1 / 2.9 cmos with 2.6 fixed lenslux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 4 sitc of 32ch 4k ivr , h.265 / h.264 • 1080p real time • 4k display • dual lan • 8x hdd • raid •web plugin free h.265 / h.264 compression technology 4k display for clear monitoring up to 1080p 16ch decoding ability smart search ii smart vca event searchsupport raid 0, 1, 5 supported to prevent from recording data loss browsers supported: ie , smart functions : target count, electric fence, face detection, humaniod detection, retrograde detection, leave position detectio output, local & network backup etc. complete as required. , cctv 5 sitc of harddiskdrive8tb, 24 / 7surveillance category only complete etc as required.etc.all complete , cctv 6 sitc of 55 led narrow bazel for monitoring for nvr server etc. all complete. , cctv 7 sitc of rj 45 outlets near the cameras etc. all complete. etc. all complete. , cctv 8 sitc of cat 6 patch cords 1 meter high quality four pair twisted stranded cable terminated with rj45 modular plugs at both the ends. , signage 1 providing & fixing of building direction signage mounted on pole, with pole of 100x100mm shs ( square hollow section ) of height of 5600mm, and sign size of 900x1050, sign made of aluminiu c section of 60mm with internal framing to support the frame in ms tubes hollow section, frame work duly painted with anti rust coatings, with facia of 3mm thick exterior grade aluminium composite panel, cladded with uv cured digital printed retroreflective sheet of 3m make, and back panel of 3mm exterior grade acp, all pipes to be painted in approved color. cost shall includecost towards installation, including excuvation and filling up with specified pcc and fixing of foundation bolts as specified, also it shall include the designing charges.all complete as per direction by engineer in charge. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , 2 tr air conditioning 1 split ac ( inverter model ) : supply, installation, testing, commissioning of split type wall mounted air conditioning units of following capacity including inddor, outdoor unit fitted with inverter based rotary compressor fitted with rotary compressor, copper condensor and first charge refrigent r410a / eco friendly green gas only, all complete including all electrical connections to the electrical power supply system of the building, includingbut not limited to supply of all electrical plugs, etc., as necessary, lengthening of all electrical wires of ac units ( both indoor and outdoor ) , drain pipe andincluding suitable voltage stabilisers, etc. so as to place them in a concealed manner in the desired position. the copper pipes and electrical cables shall be concealed in approved manner and neatly run in straight lines in a workman like manner with proper supports. complete supply and installation of split2 tr star rating 3 star , refrigerant piping copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 25 mm od, wall thickness >= 1.2 mm ( insulation 19 mm thick ) , refrigerant piping 1 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 19.1 mm od, wall thickness >= 1.0 mm ( insulation 13 mm thick ) , refrigerant piping 2 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 15.9 mm od, wall thickness >= 0.8 mm ( insulation 13 mm thick ) , refrigerant piping 3 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 9.5 mm od, wall thickness >= 0.8 mm ( insulation 13 mm thick ) , drain piping providing and fixing of cpvc 6 kg / cm2 drainpiping complete with fittings, supports, 6 mm thick closed cell elastomeric insulation as per specifications and drawings. 20 mm , drain piping 1 providing and fixing of cpvc 6 kg / cm2 drainpiping complete with fittings, supports, 6 mm thick closed cell elastomeric insulation as per specifications and drawings. 32 mm , main oxygen manifold supply, installation, testing and commissioning of following gas manifold system ( excluding cylinders ) . the manifold is configured for designed numbers of cylinders and is suitable to withstand a pressure of 145 kg / cm2, along withhigh pressure copper annealed tail pipes with end brass adapter suitable for cylinders and manifold. top frame comprising of high pressure copper pipes of size 1 / 2” nb x 15swg with high pressure brass fittings made of high tensile brass and connections through nonreturn valves, the design of middle and bottomframes is provided to fit both round and flat bottom cylinders safely. the manifold is tested ( hydraulically ) at 3500 psig. ( it should be ce and iso 13485 certified ) mani fold oxygen manifold 6 + 6 cylinder banks complete with nrv, middle frame, bottom frame with ce marked, , emergency manifold emergency oxygen manifold 01 + 01 cylinder emergency manifold with complete regulator, nrv, middle frame & bottom frame, , control panelfor oxygen fully automatic three port control panel for oxygen supply, installation, testing and commissioning of automatic manifold control panel would provide a duty or standby gas supply from two cylinder banks with automaticchangeover the manifold indicates local status and has a remote indicator facility. automaticmanifold control panel would be designed to supply the mgps with a constant pressure supply via a control panel form two equal banks of cylinders and the changeover from the ‘duty’ to the ‘standby’ bank of cylinders would beautomatic. automatic changeover from the duty to the standby bank would occur at a cylinder pressure that will ensure the maximum usage of the contents of the duty bank. the changeover unit would be provided with monitoring todetect and display: duty bank operating, duty bank empty, standby bank operating, and standby bank below 10 % when the duty bank is empty, reserve bank low, pipeline pressure fault. there would be facility to connect liquidoxygen supply ( i.e. three port control panel ) ( it should be ce and iso 13485 certified ) fully automatic three port control panel for oxygen , emergency manifold line regulator emergency manifold line regulator supply, installation, testing and commissioning of emergency manifold line regulator i n p u t p r e s s u r e 1 5 0 k g / c m 2 working pressure 4 kg / cm2 it should be ce and iso 13485 certified.oxygen input pressure 150 kg / cm2 working pressure 4 kg / cm2capacity : 1500 lpm , cylinderconnectingpipe ( pig tail ) supply, installation, testing and commissioning of cylinder connecting pipe ( pig tail ) made up of flexible ss hose with safety cord 5 / 8 inch bsp gland nut and one side 1 / 2 inch bsp internal threads having one meter length. ( oxygen 24 , n2o 10, co2 4 ) , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , medical air ( 4 bar ) outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve, supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified.42mm , isolation valve 2 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 28mm , isolation valve 3 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 22mm , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness , pipeline 4 medical grade copper pipeline ( in mtrs. ) as per en 13348, 28 mm ( od ) x 0.9 mm thickness , pipeline 5 medical grade copper pipeline ( in mtrs. ) as per en 13348, 42 mm ( od ) x 1.2 mm thickness , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 2268 mm x ( w ) 922 mm x ( h ) 610 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , paediatric bed with mattress paediatric bed of overall sizes in mm: 1500 ( l ) x 850 ( w ) x 1210 ( h ) flat single section bed with grille frame on 4 sides.suitable for children up to 12 years.drop down grill frame on both sides for protection of the patient.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral white , bed side locker type i over all dimension :402mmlx422mm wx840mm ht .locker should have one cabinet and one drawer unit .both provided with cam lock .there should be gap between drawer and unit to keep general items for frequesnt use castors are provided for easy handling .drawer made up of crca sheet 1 mm thick and has ball slide for easy operation .top ss 304 sheet 0.8 mm thick castors 50 mmdia , hamdle abs ..powder coating of epoxy polyester , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , strecher on trolley type i 2005mm ( l ) x666mm ( w ) x827mm ( h ) .the trolley should be made of 31.75 and 25.4 mm dia 1.6 mm thick erw tube.holder for stretcher should be made up of mild steel.castor should be of 200 mm dia , diagonal locking castor.stretcher should be made up oferw tubeof dia 25.4 mm and thickness 1.6 mm.top sheet should be made of crca sheetof thickness 1.2 mm with contour shape to accommodate patient.iv pole holder should be made ofms .maximum safe work load should be 135 kg.to ensure qood quality welding co2 argonprocess should be adhered to.all metal componentsshould be pre treated with zinc phosphating in 9 tank porcess and then powder coated with anti microbialepoxy polyster powder coating.goods should be supplied in knocked down construction to reduce carbon emission. performance test :proof loading test , cycle tests , impact test, salt spray test, castor break test, the manufacturer should compilant with iso 9001, 14001, 13485, ohsas 1800 and ce certification. , doctor desk type x s / f / f executive table main desk should be of dimesion : 1350w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. side panels : ( black ) made form 18mm thick plt with pvc lipping.modesty panel : made form 18mm thick plt with pvc lipping. bigger upper panel in black and smaller lower panel in white cedar. made from 18mm thick plt with pvc lipping. mobile pedestal : one box and one filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , chair type iii s / f / f executive chair1 ) seat / back assembly: the seat and back are made up of 1.2 cm. thick hot pressed plywood, upholstered withfabric upholstery covers and moulded polyurethane foam. the back foam is designed with contoured lumbar support for extra comfort. the seat has extra thick foam on front edge to give comfort to popliteal area.high back size : 47.5 cm ( w ) x 69.5 cm ( h ) seat size : 47.0 cm. ( w ) x 48.0 cm. ( d ) 2 ) polyurethane foam: the polyurethane foam is moulded with density = 45 + / 2 kg / m 3and hardness = 20 + / 2at 25% compression. 3 ) armrests: the one piece armrests are injection moulded from black co polymer polypropylene. 4 ) center tilt synchro mechanism : the mechanism is designed with the following features:• 360 revolving type. • upright position locking. • tilt tension adjustment.• seat / back tilting ratio of 1:3 ( 60 seat tilt / 180 back tilt ) . 5 ) pneumatic height adjustment : the pneumatic height adjustment has anadjustment stroke of 12.0 cm. 6 ) telescopic bellow assembly : the bellow is 3 piece telescopic type and injection moulded in black polypropylene. 7 ) pedestal assembly , staff / visitor chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck .3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement.mx load bearing capacity should be 10 kg. , hospital curtain tracks & i.v. tree system supply installation testing & commissioning of cubical tracks system made of powder coated aluminium alloy, stain free polyster fabric , water repellent curtains , smooth movement , non sticking runnner with stainless steel hooks made from mirror finish stainless steel , adjustable height with all accessories. total quantity : 1...

Health And Family Welfare Department - Bihar

30458761 bids are invited for pile boring, providing and installation bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using direct mud circulation ( dmc ) or bailer and chisel technique by tripod and mechanical winch machine all complete, including removal of excavated earth with all its lifts and leads ( length of pile for payment shall be measured up to bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , upvc door providing and fixing of factory made upvc white colour casement door, upvc multichambered extruted frame, sash and mullion profile. frame duly reinforced with 1.2mm gi section box tpe chamber and sash with 1.5mm thick gi section ( ± 0.2mm ) based on wind load calculations ( shape and size according to upvc profiles ) , appropiate dimentions of upvc extruded glazing bead, epdm gasket ( k / o type ) , seperate drainage system, ss34 grade friction hinges 2d / 3d plate hinges, zinc alloy ( white powder coated ) casement handle, gi fastener 8x100 mm size for fixing frame to finish wall, plastic packer and caps and necessary steel screws etc.profile of frame and sash shall be metered cut and fusion welded at all corners, mullion shall be also fusion welded / joined mechanically including drilling of holes for fixing hardware and drainage of water etc. after fixing of frames , gap between frame and adjascent wall shall be filled with pu foaam / backer rod required size and the approved quantity. after that sealed with weather proof silicon sealant at both side, all complete as per approved drawing and direction of eic , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 1 providing and laying vitrified floor tiles in different sizes ( thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including grouting the joints with white cement and matching pigments etc., complete. size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge :flamed finish granite stone slab jet black, cherry red, elitebrown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item ( galvanised@80gsm ) 50 mm long 8mmouter diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’ , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975. the wind load shall be as per provisions of is 875 ( part iii ) . lgsfs frame shall be designed as per is: 801 using commercially available software such as frame cad pro 11.7 / staad pro v8i / architekv2.5.16 / revit architecture 2011 or equivalent. proper usage of connection accessories like heavy duty tension ties, light duty hold ons, twist straps ( to connect truss with wall frames ) , strong tie, tie rod, h brackets, boxing sections, l shaped angles for better structural stability. the framing section shall be cold form c type having minimum web depth 89 mm x 39mm flange x 11mm lip in required length as per structural design requirement duly punched with dimple / slot at required locations as per approved drawings. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm and. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , face panel providing and fixing in all exterior face panels breathable vapour barrier underneath the cementfiber board as per national building code 2009 complete as per direction of engineer in charge. , lap siding supplying and installation of moisture resistant / fire resistantlap siding 8 mm thick and width as per standard sizes made ofiber cement board with embossed decorative finish to give pleasing exterior fixed horizontally with staggered joints including minimum over lapof 32 mm external cement fibre boardconforming to is 14862:2000 offixed with self drilling / taping screws / fastners of approved make. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1 new work ( two or more coats ) over and including water tinnable priming coat with cement primer , ex. paint finishing walls with textured exterior paint of required shade : new work ( two or more coats applied @ 3.28 ltr / 10 sqm ) over and including priming coat of exterior primer applied @ 2.20kg / 10 sqm sqm , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel 1 steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , road providing and laying c.c. pavement of mix m 25 with ready mixed concrete from batching plant. the ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc.complete as per specifications and directions of engineer in charge. ( the panel shuttering work shall be paid for separately ) . ( note: cement content considered in this item is @ 330 kg / cum. excess / less cement used as per design mix is payable / recoverableseparately ) . , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 1 providing & fixing stone slab table rubbed, edges rounded and polished of size 75 x 50cm deep and 1.8 cm thick fixed in urinal patitions by cutting chase of appropriate width with chase cutter and embedding the stone in chase with epoxy grout or with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregste 6mm nominal size ) as per engineer in charge and finished smooth white agaria marble stone , phe 2 providing and fixing salem stainless steel a isi 304 ( 18 / 8 ) kitchen sink as per is: 13983 with ci brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required. kitchen sink with drain board510x1040mm bowl depth 200mm. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing:rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixturescomplete, including cutting and making good the walls andlevel whitep.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings andfloors wherever required :white vitreous china orissa pattern w.c. pan of size580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 9 providing and fixing cp brass 32mm size bottle trap of approved quality & make and as per the direction of engineer in charge.. ( sink & urinal ) , phe 10 providing & fixingptmt towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealedfittings arrangement of approved quality and colour weighing not less than 88 gms , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size 660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 15 providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water ( 250 ml & 500 ml consumption ) , having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of engineer in charge.. , phe 16 providing & fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. , phe 17 providing and fixing white vitreous china laboratory sink with c.i. brackets, c.p. brass chain with rubber plug, 40 mm c.p brass waste and 40mm c.p. brass trap with necessary c.p. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required :size 600x450x200 mm , phe 18 providing and fixing cp brass single lever telephonic wall mixer of quality & make as approved by engineer in charge . a ) 15 mm nominal dia. , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 21 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 24 two or more coats on new work over an under coat ofsuitable shade with ordinary paint of approved brand andmanufacturetwo more coast on new work , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm.clear depth and 250mm apron including cost of e / w. involved with 75mmcement concrete ( 1:4:8 ) over one brick designation 100 a flat soling inproper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 8 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia. exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 11 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 450 mm dia rcc pipe , ex. phe 12 inside size 120x90 cm and 90 cm deep including c.i. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg ) :with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , ex. phe 13 providing and fixing square mouth sw gully trap grade ‘a’ complete ci grating brick masonry chamber with bricks of class designation 75 and water tight ci cover with frame of 300 x 300 mm size ( inside ) the weight of cover to be not less than 13.00 kg and frame to be not less than 5 kg. as per standard design. ( cover min. 4.5 kg & frame min.2.7 kg ) 180x150 mm size p type with fps bricks , ex. phe 14 constructing masonry chamber 30x30x50 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement:4 coarce sand ) for stop cock complete with c.i. surface box 100x100x75mm ( inside ) with locking arrangement and rcc top slab 1:2:4 mix ( 1 cement : 2 corase sand: 4 graded stonr aggregate 20mm nominal size ) necessary excavation foundation concret 1:5:10 ( 1 cement:5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortor 1:3 ( 1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design. , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , ex. phe 16 structual steel work welded in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. , ex. phe 17 making connection of gi distribution branch with gi main of 50 80mm nominal bore by providing and fixing tee, including cutting and threading the pipe etc. complete. , rain water harvesting 1 boring / drilling bore well of required dia for casing / strainer pipe, bysuitable method prescribed in is:2800 ( part i ) , including collecting sample from different strata , preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90m depth below ground level.300 mm dia , rain water harvesting 2 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150mm nominal size dia , rain water harvesting 3 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well screen ( rms ) pipes with ribs, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150 mm nominal size dia , rain water harvesting 4 supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 5 supplying, filling, spreading & levelling gravel of size range 5mm to 10mm, in recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 7 providing and fixing bail plug / bottom plug of required dia to the bottom of pipe assembly of tube well as per is:2800 ( part i ) . 100 mm dia , rain water harvesting 8 making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and s.w. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , rain water harvesting 9 constructing soak pit 1.20x1.20x1.20 m filled with brickbats including s.w. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , tubewell 1 boring / drilling bore well of required dia for casing / strainer pipe, bysuitable method prescribed in is:2800 ( part i ) , including collecting sample from different strata , preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90m depth below ground level.300 mm dia , tubewell 2 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150mm nominal size dia , tubewell 3 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.100mm nominal size dia , tubewell 4 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well screen ( rms ) pipes with ribs, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.100 mm nominal size dia , tubewell 5 supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , tubewell 6 providing and fixing bail plug / bottom plug of required dia to the bottom of pipe assembly of tube well as per is:2800 ( part i ) . 100 mm dia , submersible pump 35m deep boring with casing and pipe. supply of pipe etc supplying & installation of suitable 2hp submersible pump b.s or k.s.bor equivalent make with finolex cable 1x3x2.5 squmm ( upto 50mtr ) withflexible conduit 25mm dia, electrical out door pannel with required electrical fitting such as mcb of 0 25amp ( havell or indocopp or mds make ) , volt & ampere meter ( ae make ) , single phase preventer ( minilac or vsp 1 make ) starter ( l&t or bch make ) etc of approved make, 40mm hdpe pipe ( 25 mtr ) and all accessories complete as per requirement of site. , water purifier and cooler 1 fitting and fixing single faucet storage type water cooler ( size 461 mm wide x 582 mm deep x 1217 mm height, weight 46 kg ) fully stainless body having storage capacity of 40 ltrs, cooling capacity of 40 ltrs. / hr. with hermetic type compressor, gas cooled motor equipped with over load protector, condensor for propeller type, thermostat autometically controlled temperature, refrigerent r 22, 230 volt, single phase 50 hertz, maximum current 2.3 amp including plug top and electrical lead wire connection upto 3 metres from the cooler, water inlet and drain out connections complete in all respects of voltas model no 40 / 40 tushar pss type or similar type of approved make. , water purifier and cooler 2 fitting and fixing water purifier for drinking purpose of capacity 6 litres / min, 5 purification system with reverse osmosis system with ultra ventilated membrane, tds500 to 2000 mgl / ppm, auto shut off with microswitch float manual flush facility, tds reduction 90% having automatic backwash system with filteration unit along with all accessories including plug top and electrical lead wire connection upto 3 metres from the purifier, water inlet and drain out connections complete in all respects similar to aquaguard or similar approved make ( model aquasure elegant ro water purifier of size width 360 mm x height 430 mm x depth 235 mm and weight 8.5 kg ) . , fire extinguisher 1 providing and fixing carbon di oxide type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. capacity 4.5 kg. , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 6.0 kg. , electrical 1 wiring for light point / fan point / exhaust fan point / call bellpoint with 1.5 sq.mm frls pvc insulated copper conductorsingle core cable in surface / recessed steel conduit, withmodular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. group c , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , pvc conduit 1 supplying and fixing of following sizes of medium class 20mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , pvc conduit 2 supplying and fixing of following sizes of medium class 32mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , pvc conduit 3 supplying and fixing of following sizes of medium class 50mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , electrical 4 wiring for light / power plug with 2x4 sq. mm frls pvcinsulated copper conductor single core cable in surface / recessed conduit alongwith 1 no. 4 sq. mm frls pvcinsulated copper conductor single core cable for loop earthingas required. , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 4 x 6 sq. mm + 2 x 6 sq. mm earth wire , wiring frls pvc insulated copper conductor 4 4 x 10 sq. mm + 2 x 6 sq. mm earth wire , wiring frls pvc insulated copper conductor 5 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 1 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 3 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 4 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 2 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 3 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 4 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 5 telephone socket outlet , s / f modular switch / socket on the existing modular plate 6 tv antenna socket outlet , s / f modular switch / socket on the existing modular plate 7 bell push , electrical 5 supplying & fixing suitable size gi box wih modular plate and cover in front on surface or in recess including providing and fixing 25 a modular socket outlet and 25 a modular sp mcb, “c” curve including connections, painting etc. as required. ( for ac / geyser ) , electrical 6 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface / recessed steel / pvc conduit as required. , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 11 supplying and fixing 20 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. , electrical 12 supplying and fixing 30 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , electrical 14 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 12 way , double door , electrical 15 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 16 way, double door , electrical 16 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 6 way ( 4 + 18 ) , double door , electrical 17 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way ( 4 + 24 ) , double door , electrical 18 supplying and fixing of following ways surface / recess mounting, vertical type, 415 v, tpn mcb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 a tinned copper bus bar, common neutral link, earth bar, din bar for mounting mcbs ( but without mcbs and incomer ) as required . ( note : vertical type mcb tpdb is normally usedwhere 3 phase outlets are required. ) 4 way ( 4 + 12 ) , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 63a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 100a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , l / f pvc sheathed / xlpe power cable in trench laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 95 sq. mm and upto 185 sq. mm , l / f pvc sheathed / xlpe power cable in trench 1 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 185 sq. mm and upto 400 sq. mm , l / f pvc sheathed / xlpe power cable over cable tray upto 35 sq. mm ( clamped with 1mm thick saddle ) , l / f pvc sheathed / xlpe power cable over cable tray 2 above 35 sq. mm and upto 95 sq. mm ( clamped with 25x3mm ms flat clamp ) , l / f pvc sheathed / xlpe power cable over cable tray 3 above 95 sq. mm and upto 185 sq. mm ( clamped with 25 / 40x3mm ms flat clamp ) , l / f pvc sheathed / xlpe power cable over cable tray 4 above 185 sq. mm and upto 400 sq. mm ( clamped with 40x3mm ms flat clamp ) , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 3.5c x 300 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 1 3.5c x 240 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 2 3.5c x 120 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 3 3.5c x 95 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 4 3.5c x 50 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 5 4c x 35 sqmm aluminium conductor cable a2xfy , cable tray supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 100 mm width x 50 mm depth x 1.6 mm thickness , cable tray 1 supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 300 mm width x 50 mm depth x 1.6 mm thickness , cable tray 2 supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 600 mm width x 62.5 mm depth x 2.0 mm thickness , cable tray “bends” supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.100 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 1 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.150 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 2 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.300 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 3 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.450 mm width x 50 mm depth x 2 mm thickness , cable tray “bends” 4 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.600 mm width x 62.5 mm depth x 2.0 mm thickness , mv cable supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 300 sqmm, aluminium conductor cable a2xfy , mv cable 1 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 240 sqmm, aluminium conductor cable a2xfy , mv cable 2 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 120 sqmm, aluminium conductor cable a2xfy , mv cable 3 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 95 sqmm, aluminium conductor cable a2xfy , earthing earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 1 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. , earthing 2 earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. , earthing 3 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 4 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , earthing 5 providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required. , earthing 6 providing and fixing earth bus of 50 mm x 5 mm copper strip on surface for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 4 supplying and fixing recess mounted 12 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 6 supply, installation, testing and commissioning of 400 mm sweep, 65w, blade material aluminium blades , speed & oscillation 3 speed, pull cord for speed and oscillation.air delivery minimum 72 m³ / min, speed minimun 1350 revolution per minute.suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , fiting & fixtures 8 supplying installation testing & commissioning ofb22 based 9w led 3 star bulb with 850 lumen, 6k color temperature including holder. , fiting & fixtures 9 supplying installation testing & commissioning of black painted extruded aluminium housing. green / red led’s mounted inside the housing. laser engraved signage matter on single / double acrylic sheet fixed on one side suitable for wall / ceiling / suspension type single / double sided display. in double sided version black paper is inserted. ni cd battery back up to 2 hrs. ( charged up to 8 10 hrs ) .mounting strings provided for pendent mounting operating voltage 150 280v ac ambient operating temperature. – 0 to 450c ingress protection – ip42.including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required.   220208 besl 03 led ssd wbb green 240 3 8wor220209 besl 03 led ssd wbb red 240 3 8wor220210 besl 03 led dsd wbb green 240 3 8wor220211 besl 03 led dsd wbb red 240 3 8w , fiting & fixtures 10 supply, installation, testing & erecting of ip66 bulkhead surface type lighting fixture 10w made up of pressure die cast aluminium housing and polyster powder coated die cast aluminium with high quality polycarbonate diffuser in opal finish for glare free light distribution.high efficiency long life led module with smd led package mounted on mcpcb with lumen efficacy of >95 lm / w with system lumen 950. powered by integral electronic led driver with apfc with low thd output short / open circuit protection. cct 5700, cri>80, system efficacy>90lm / w, thd<15%, pf>.95, ip66, ik 10, life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz.including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. cat ref: havells : hexaft10wled857ssymbopc or approved equivalent. , civil & misc works1 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. , civil & misc works2 providing and fixing h.t. danger notice plate of 250 mm x 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. , civil & misc works3 supplying and making cable route marker with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm x 60 cm at the bottom and 50 cm x 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. , civil & misc works4 supplying and fixing cable route marker with 10 cm x 10 cm x 5 mm thick g.i. plate with inscription there on, bolted / welded to 35 mm x 35 mm x 6 mm angle iron, 60 cm long and fixing the same in ground as required. , civil & misc works5 providing & fixing in position 1000 mm wide , electrical insulating rubber mats as per is 15652:2006, 2 mm thick, suitable up to 1.1 kv , fire retardant, no effect of acids, alkalis and transformer oils, moisture proof, high tensile strengthandtexture finish / cloth impression ( anti slip , marking on top ) , civil & misc works6 supply & fixing shock treatment chart duly mounted on a wooden frame with 5 mm thick glass as required ( approx front area 1.20 sq metre ) , 40 kvaups supplying, installation, testing and commissioningof online double conversion fully microprocessor based , indoor type, compact ups system of following rating with igbt based pwm technology to achieve thd < 3% and input power factor of greater than 0.95 at 50% loading, suitable for three phase ac input voltage 380 v to 440 v, 50 hz +3% / 3 % and three phase ac output voltage 415 ± 1% volts & frequency 50 ± 0.5 hz , inbuilt isolation transformer, necessary vrla batteries of suitable size having 30 minutes back up time , mounting rack including and suitable size connecting cable ( for ups to battery and battery to battery ) , static and maintenance bypass switch, snmp card for rs232 / ethernet ip computability for operation and monitoring etc. with all components as mentioned , specifications, complete as required.note : concerning vendor needs to furnish the battery sizing calculations at the time of ga approval and battery size has to be as per the approved ga drawing. , external lighting 1 supply and erection of 4 metre height hot dipgalvanized octagonal street light pole with followingarm with top dia 70 mm and bottom dia a / f 130 mm, made of 3 mm thick sheet along with base plate of size220 x 220 x 12 mm , small door opening for junctionbox mounting with mcb & connector, cement concreteof 1:3:6 including excavation, refilling and suitable sizefoundation bolts with template and all complete jobasrequired. ( but without pole collar ) single arm , external lighting 2 supplying and fixing 40 / 45 watt led type street lightwith die cast aluminium housing for ingress protectionof ip65 and complete with all accessories etc, onpole / building including connection with fr pvcinsulated copper conductor cable and earthing thebody etc. as required. , ip based cctv system 1 sitc of 2 megapixel @ 25fps, h.265 ip bullet camera, 1 / 2.9 cmos with 2.8~12mm varifocal lens, 0 lux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 2 sitc of 2 megapixel @ 25fps, h.265 ip dome camera, 1 / 2.9 cmos with 3.6 fixed mm 0 lux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 3 sitc of 2 megapixel @ 25fps, ptz camera h.265 ip dome camera, 1 / 2.9 cmos with 2.6 fixed lenslux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 4 sitc of 32ch 4k ivr , h.265 / h.264 • 1080p real time • 4k display • dual lan • 8x hdd • raid •web plugin free h.265 / h.264 compression technology 4k display for clear monitoring up to 1080p 16ch decoding ability smart search ii smart vca event searchsupport raid 0, 1, 5 supported to prevent from recording data loss browsers supported: ie , smart functions : target count, electric fence, face detection, humaniod detection, retrograde detection, leave position detectio output, local & network backup etc. complete as required. , cctv 5 sitc of harddiskdrive8tb, 24 / 7surveillance category only complete etc as required.etc.all complete , cctv 6 sitc of 55 led narrow bazel for monitoring for nvr server etc. all complete. , cctv 7 sitc of rj 45 outlets near the cameras etc. all complete. etc. all complete. , cctv 8 sitc of cat 6 patch cords 1 meter high quality four pair twisted stranded cable terminated with rj45 modular plugs at both the ends. , signage 1 providing & fixing of building direction signage mounted on pole, with pole of 100x100mm shs ( square hollow section ) of height of 5600mm, and sign size of 900x1050, sign made of aluminiu c section of 60mm with internal framing to support the frame in ms tubes hollow section, frame work duly painted with anti rust coatings, with facia of 3mm thick exterior grade aluminium composite panel, cladded with uv cured digital printed retroreflective sheet of 3m make, and back panel of 3mm exterior grade acp, all pipes to be painted in approved color. cost shall includecost towards installation, including excuvation and filling up with specified pcc and fixing of foundation bolts as specified, also it shall include the designing charges.all complete as per direction by engineer in charge. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , 2 tr air conditioning 1 split ac ( inverter model ) : supply, installation, testing, commissioning of split type wall mounted air conditioning units of following capacity including inddor, outdoor unit fitted with inverter based rotary compressor fitted with rotary compressor, copper condensor and first charge refrigent r410a / eco friendly green gas only, all complete including all electrical connections to the electrical power supply system of the building, includingbut not limited to supply of all electrical plugs, etc., as necessary, lengthening of all electrical wires of ac units ( both indoor and outdoor ) , drain pipe andincluding suitable voltage stabilisers, etc. so as to place them in a concealed manner in the desired position. the copper pipes and electrical cables shall be concealed in approved manner and neatly run in straight lines in a workman like manner with proper supports. complete supply and installation of split2 tr star rating 3 star , refrigerant piping copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 25 mm od, wall thickness >= 1.2 mm ( insulation 19 mm thick ) , refrigerant piping 1 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 19.1 mm od, wall thickness >= 1.0 mm ( insulation 13 mm thick ) , refrigerant piping 2 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 15.9 mm od, wall thickness >= 0.8 mm ( insulation 13 mm thick ) , refrigerant piping 3 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 9.5 mm od, wall thickness >= 0.8 mm ( insulation 13 mm thick ) , drain piping providing and fixing of cpvc 6 kg / cm2 drainpiping complete with fittings, supports, 6 mm thick closed cell elastomeric insulation as per specifications and drawings. 20 mm , drain piping 1 providing and fixing of cpvc 6 kg / cm2 drainpiping complete with fittings, supports, 6 mm thick closed cell elastomeric insulation as per specifications and drawings. 32 mm , main oxygen manifold supply, installation, testing and commissioning of following gas manifold system ( excluding cylinders ) . the manifold is configured for designed numbers of cylinders and is suitable to withstand a pressure of 145 kg / cm2, along withhigh pressure copper annealed tail pipes with end brass adapter suitable for cylinders and manifold. top frame comprising of high pressure copper pipes of size 1 / 2” nb x 15swg with high pressure brass fittings made of high tensile brass and connections through nonreturn valves, the design of middle and bottomframes is provided to fit both round and flat bottom cylinders safely. the manifold is tested ( hydraulically ) at 3500 psig. ( it should be ce and iso 13485 certified ) mani fold oxygen manifold 6 + 6 cylinder banks complete with nrv, middle frame, bottom frame with ce marked, , emergency manifold emergency oxygen manifold 01 + 01 cylinder emergency manifold with complete regulator, nrv, middle frame & bottom frame, , control panelfor oxygen fully automatic three port control panel for oxygen supply, installation, testing and commissioning of automatic manifold control panel would provide a duty or standby gas supply from two cylinder banks with automaticchangeover the manifold indicates local status and has a remote indicator facility. automaticmanifold control panel would be designed to supply the mgps with a constant pressure supply via a control panel form two equal banks of cylinders and the changeover from the ‘duty’ to the ‘standby’ bank of cylinders would beautomatic. automatic changeover from the duty to the standby bank would occur at a cylinder pressure that will ensure the maximum usage of the contents of the duty bank. the changeover unit would be provided with monitoring todetect and display: duty bank operating, duty bank empty, standby bank operating, and standby bank below 10 % when the duty bank is empty, reserve bank low, pipeline pressure fault. there would be facility to connect liquidoxygen supply ( i.e. three port control panel ) ( it should be ce and iso 13485 certified ) fully automatic three port control panel for oxygen , emergency manifold line regulator emergency manifold line regulator supply, installation, testing and commissioning of emergency manifold line regulator i n p u t p r e s s u r e 1 5 0 k g / c m 2 working pressure 4 kg / cm2 it should be ce and iso 13485 certified.oxygen input pressure 150 kg / cm2 working pressure 4 kg / cm2capacity : 1500 lpm , cylinderconnectingpipe ( pig tail ) supply, installation, testing and commissioning of cylinder connecting pipe ( pig tail ) made up of flexible ss hose with safety cord 5 / 8 inch bsp gland nut and one side 1 / 2 inch bsp internal threads having one meter length. ( oxygen 24 , n2o 10, co2 4 ) , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , medical air ( 4 bar ) outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve, supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified.42mm , isolation valve 2 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 28mm , isolation valve 3 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 22mm , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness , pipeline 4 medical grade copper pipeline ( in mtrs. ) as per en 13348, 28 mm ( od ) x 0.9 mm thickness , pipeline 5 medical grade copper pipeline ( in mtrs. ) as per en 13348, 42 mm ( od ) x 1.2 mm thickness , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 2268 mm x ( w ) 922 mm x ( h ) 610 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , paediatric bed with mattress paediatric bed of overall sizes in mm: 1500 ( l ) x 850 ( w ) x 1210 ( h ) flat single section bed with grille frame on 4 sides.suitable for children up to 12 years.drop down grill frame on both sides for protection of the patient.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral white , bed side locker type i over all dimension :402mmlx422mm wx840mm ht .locker should have one cabinet and one drawer unit .both provided with cam lock .there should be gap between drawer and unit to keep general items for frequesnt use castors are provided for easy handling .drawer made up of crca sheet 1 mm thick and has ball slide for easy operation .top ss 304 sheet 0.8 mm thick castors 50 mmdia , hamdle abs ..powder coating of epoxy polyester , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , strecher on trolley type i 2005mm ( l ) x666mm ( w ) x827mm ( h ) .the trolley should be made of 31.75 and 25.4 mm dia 1.6 mm thick erw tube.holder for stretcher should be made up of mild steel.castor should be of 200 mm dia , diagonal locking castor.stretcher should be made up oferw tubeof dia 25.4 mm and thickness 1.6 mm.top sheet should be made of crca sheetof thickness 1.2 mm with contour shape to accommodate patient.iv pole holder should be made ofms .maximum safe work load should be 135 kg.to ensure qood quality welding co2 argonprocess should be adhered to.all metal componentsshould be pre treated with zinc phosphating in 9 tank porcess and then powder coated with anti microbialepoxy polyster powder coating.goods should be supplied in knocked down construction to reduce carbon emission. performance test :proof loading test , cycle tests , impact test, salt spray test, castor break test, the manufacturer should compilant with iso 9001, 14001, 13485, ohsas 1800 and ce certification. , doctor desk type x s / f / f executive table main desk should be of dimesion : 1350w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. side panels : ( black ) made form 18mm thick plt with pvc lipping.modesty panel : made form 18mm thick plt with pvc lipping. bigger upper panel in black and smaller lower panel in white cedar. made from 18mm thick plt with pvc lipping. mobile pedestal : one box and one filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , chair type iii s / f / f executive chair1 ) seat / back assembly: the seat and back are made up of 1.2 cm. thick hot pressed plywood, upholstered withfabric upholstery covers and moulded polyurethane foam. the back foam is designed with contoured lumbar support for extra comfort. the seat has extra thick foam on front edge to give comfort to popliteal area.high back size : 47.5 cm ( w ) x 69.5 cm ( h ) seat size : 47.0 cm. ( w ) x 48.0 cm. ( d ) 2 ) polyurethane foam: the polyurethane foam is moulded with density = 45 + / 2 kg / m 3and hardness = 20 + / 2at 25% compression. 3 ) armrests: the one piece armrests are injection moulded from black co polymer polypropylene. 4 ) center tilt synchro mechanism : the mechanism is designed with the following features:• 360 revolving type. • upright position locking. • tilt tension adjustment.• seat / back tilting ratio of 1:3 ( 60 seat tilt / 180 back tilt ) . 5 ) pneumatic height adjustment : the pneumatic height adjustment has anadjustment stroke of 12.0 cm. 6 ) telescopic bellow assembly : the bellow is 3 piece telescopic type and injection moulded in black polypropylene. 7 ) pedestal assembly : . , staff / visitor chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck .3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement.mx load bearing capacity should be 10 kg. , hospital curtain tracks & i.v. tree system supply installation testing & commissioning of cubical tracks system made of powder coated aluminium alloy, stain free polyster fabric , water repellent curtains , smooth movement , non sticking runnner with stainless steel hooks made from mirror finish stainless steel , adjustable height with all accessories. total quantity : 1...

Health And Family Welfare Department - Bihar

30457596 bids are invited for pile boring, providing and installation bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using direct mud circulation ( dmc ) or bailer and chisel technique by tripod and mechanical winch machine all complete, including removal of excavated earth with all its lifts and leads ( length of pile for payment shall be measured up to bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , upvc door providing and fixing of factory made upvc white colour casement door, upvc multichambered extruted frame, sash and mullion profile. frame duly reinforced with 1.2mm gi section box tpe chamber and sash with 1.5mm thick gi section ( ± 0.2mm ) based on wind load calculations ( shape and size according to upvc profiles ) , appropiate dimentions of upvc extruded glazing bead, epdm gasket ( k / o type ) , seperate drainage system, ss34 grade friction hinges 2d / 3d plate hinges, zinc alloy ( white powder coated ) casement handle, gi fastener 8x100 mm size for fixing frame to finish wall, plastic packer and caps and necessary steel screws etc.profile of frame and sash shall be metered cut and fusion welded at all corners, mullion shall be also fusion welded / joined mechanically including drilling of holes for fixing hardware and drainage of water etc. after fixing of frames , gap between frame and adjascent wall shall be filled with pu foaam / backer rod required size and the approved quantity. after that sealed with weather proof silicon sealant at both side, all complete as per approved drawing and direction of eic , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 1 providing and laying vitrified floor tiles in different sizes ( thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including grouting the joints with white cement and matching pigments etc., complete. size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge :flamed finish granite stone slab jet black, cherry red, elitebrown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item ( galvanised@80gsm ) 50 mm long 8mmouter diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’ , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975. the wind load shall be as per provisions of is 875 ( part iii ) . lgsfs frame shall be designed as per is: 801 using commercially available software such as frame cad pro 11.7 / staad pro v8i / architekv2.5.16 / revit architecture 2011 or equivalent. proper usage of connection accessories like heavy duty tension ties, light duty hold ons, twist straps ( to connect truss with wall frames ) , strong tie, tie rod, h brackets, boxing sections, l shaped angles for better structural stability. the framing section shall be cold form c type having minimum web depth 89 mm x 39mm flange x 11mm lip in required length as per structural design requirement duly punched with dimple / slot at required locations as per approved drawings. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm and. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , face panel providing and fixing in all exterior face panels breathable vapour barrier underneath the cementfiber board as per national building code 2009 complete as per direction of engineer in charge. , lap siding supplying and installation of moisture resistant / fire resistantlap siding 8 mm thick and width as per standard sizes made ofiber cement board with embossed decorative finish to give pleasing exterior fixed horizontally with staggered joints including minimum over lapof 32 mm external cement fibre boardconforming to is 14862:2000 offixed with self drilling / taping screws / fastners of approved make. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1 new work ( two or more coats ) over and including water tinnable priming coat with cement primer , ex. paint finishing walls with textured exterior paint of required shade : new work ( two or more coats applied @ 3.28 ltr / 10 sqm ) over and including priming coat of exterior primer applied @ 2.20kg / 10 sqm sqm , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel 1 steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , road providing and laying c.c. pavement of mix m 25 with ready mixed concrete from batching plant. the ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc.complete as per specifications and directions of engineer in charge. ( the panel shuttering work shall be paid for separately ) . ( note: cement content considered in this item is @ 330 kg / cum. excess / less cement used as per design mix is payable / recoverableseparately ) . , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 1 providing & fixing stone slab table rubbed, edges rounded and polished of size 75 x 50cm deep and 1.8 cm thick fixed in urinal patitions by cutting chase of appropriate width with chase cutter and embedding the stone in chase with epoxy grout or with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregste 6mm nominal size ) as per engineer in charge and finished smooth white agaria marble stone , phe 2 providing and fixing salem stainless steel a isi 304 ( 18 / 8 ) kitchen sink as per is: 13983 with ci brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required. kitchen sink with drain board510x1040mm bowl depth 200mm. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing:rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixturescomplete, including cutting and making good the walls andlevel whitep.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings andfloors wherever required :white vitreous china orissa pattern w.c. pan of size580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 9 providing and fixing cp brass 32mm size bottle trap of approved quality & make and as per the direction of engineer in charge.. ( sink & urinal ) , phe 10 providing & fixingptmt towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealedfittings arrangement of approved quality and colour weighing not less than 88 gms , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size 660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 15 providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water ( 250 ml & 500 ml consumption ) , having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of engineer in charge.. , phe 16 providing & fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. , phe 17 providing and fixing white vitreous china laboratory sink with c.i. brackets, c.p. brass chain with rubber plug, 40 mm c.p brass waste and 40mm c.p. brass trap with necessary c.p. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required :size 600x450x200 mm , phe 18 providing and fixing cp brass single lever telephonic wall mixer of quality & make as approved by engineer in charge . a ) 15 mm nominal dia. , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 21 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 24 two or more coats on new work over an under coat ofsuitable shade with ordinary paint of approved brand andmanufacturetwo more coast on new work , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm.clear depth and 250mm apron including cost of e / w. involved with 75mmcement concrete ( 1:4:8 ) over one brick designation 100 a flat soling inproper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 8 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia. exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 11 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 450 mm dia rcc pipe , ex. phe 12 inside size 120x90 cm and 90 cm deep including c.i. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg ) :with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , ex. phe 13 providing and fixing square mouth sw gully trap grade ‘a’ complete ci grating brick masonry chamber with bricks of class designation 75 and water tight ci cover with frame of 300 x 300 mm size ( inside ) the weight of cover to be not less than 13.00 kg and frame to be not less than 5 kg. as per standard design. ( cover min. 4.5 kg & frame min.2.7 kg ) 180x150 mm size p type with fps bricks , ex. phe 14 constructing masonry chamber 30x30x50 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement:4 coarce sand ) for stop cock complete with c.i. surface box 100x100x75mm ( inside ) with locking arrangement and rcc top slab 1:2:4 mix ( 1 cement : 2 corase sand: 4 graded stonr aggregate 20mm nominal size ) necessary excavation foundation concret 1:5:10 ( 1 cement:5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortor 1:3 ( 1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design. , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , ex. phe 16 structual steel work welded in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. , ex. phe 17 making connection of gi distribution branch with gi main of 50 80mm nominal bore by providing and fixing tee, including cutting and threading the pipe etc. complete. , rain water harvesting 1 boring / drilling bore well of required dia for casing / strainer pipe, bysuitable method prescribed in is:2800 ( part i ) , including collecting sample from different strata , preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90m depth below ground level.300 mm dia , rain water harvesting 2 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150mm nominal size dia , rain water harvesting 3 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well screen ( rms ) pipes with ribs, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150 mm nominal size dia , rain water harvesting 4 supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 5 supplying, filling, spreading & levelling gravel of size range 5mm to 10mm, in recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 7 providing and fixing bail plug / bottom plug of required dia to the bottom of pipe assembly of tube well as per is:2800 ( part i ) . 100 mm dia , rain water harvesting 8 making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and s.w. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , rain water harvesting 9 constructing soak pit 1.20x1.20x1.20 m filled with brickbats including s.w. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , tubewell 1 boring / drilling bore well of required dia for casing / strainer pipe, bysuitable method prescribed in is:2800 ( part i ) , including collecting sample from different strata , preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90m depth below ground level.300 mm dia , tubewell 2 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150mm nominal size dia , tubewell 3 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.100mm nominal size dia , tubewell 4 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well screen ( rms ) pipes with ribs, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.100 mm nominal size dia , tubewell 5 supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , tubewell 6 providing and fixing bail plug / bottom plug of required dia to the bottom of pipe assembly of tube well as per is:2800 ( part i ) . 100 mm dia , submersible pump 35m deep boring with casing and pipe. supply of pipe etc supplying & installation of suitable 2hp submersible pump b.s or k.s.bor equivalent make with finolex cable 1x3x2.5 squmm ( upto 50mtr ) withflexible conduit 25mm dia, electrical out door pannel with required electrical fitting such as mcb of 0 25amp ( havell or indocopp or mds make ) , volt & ampere meter ( ae make ) , single phase preventer ( minilac or vsp 1 make ) starter ( l&t or bch make ) etc of approved make, 40mm hdpe pipe ( 25 mtr ) and all accessories complete as per requirement of site. , water purifier and cooler 1 fitting and fixing single faucet storage type water cooler ( size 461 mm wide x 582 mm deep x 1217 mm height, weight 46 kg ) fully stainless body having storage capacity of 40 ltrs, cooling capacity of 40 ltrs. / hr. with hermetic type compressor, gas cooled motor equipped with over load protector, condensor for propeller type, thermostat autometically controlled temperature, refrigerent r 22, 230 volt, single phase 50 hertz, maximum current 2.3 amp including plug top and electrical lead wire connection upto 3 metres from the cooler, water inlet and drain out connections complete in all respects of voltas model no 40 / 40 tushar pss type or similar type of approved make. , water purifier and cooler 2 fitting and fixing water purifier for drinking purpose of capacity 6 litres / min, 5 purification system with reverse osmosis system with ultra ventilated membrane, tds500 to 2000 mgl / ppm, auto shut off with microswitch float manual flush facility, tds reduction 90% having automatic backwash system with filteration unit along with all accessories including plug top and electrical lead wire connection upto 3 metres from the purifier, water inlet and drain out connections complete in all respects similar to aquaguard or similar approved make ( model aquasure elegant ro water purifier of size width 360 mm x height 430 mm x depth 235 mm and weight 8.5 kg ) . , fire extinguisher 1 providing and fixing carbon di oxide type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. capacity 4.5 kg. , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 6.0 kg. , electrical 1 wiring for light point / fan point / exhaust fan point / call bellpoint with 1.5 sq.mm frls pvc insulated copper conductorsingle core cable in surface / recessed steel conduit, withmodular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. group c , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , pvc conduit 1 supplying and fixing of following sizes of medium class 20mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , pvc conduit 2 supplying and fixing of following sizes of medium class 32mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , pvc conduit 3 supplying and fixing of following sizes of medium class 50mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , electrical 4 wiring for light / power plug with 2x4 sq. mm frls pvcinsulated copper conductor single core cable in surface / recessed conduit alongwith 1 no. 4 sq. mm frls pvcinsulated copper conductor single core cable for loop earthingas required. , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 4 x 6 sq. mm + 2 x 6 sq. mm earth wire , wiring frls pvc insulated copper conductor 4 4 x 10 sq. mm + 2 x 6 sq. mm earth wire , wiring frls pvc insulated copper conductor 5 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 1 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 3 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 4 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 2 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 3 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 4 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 5 telephone socket outlet , s / f modular switch / socket on the existing modular plate 6 tv antenna socket outlet , s / f modular switch / socket on the existing modular plate 7 bell push , electrical 5 supplying & fixing suitable size gi box wih modular plate and cover in front on surface or in recess including providing and fixing 25 a modular socket outlet and 25 a modular sp mcb, “c” curve including connections, painting etc. as required. ( for ac / geyser ) , electrical 6 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface / recessed steel / pvc conduit as required. , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 11 supplying and fixing 20 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. , electrical 12 supplying and fixing 30 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , electrical 14 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 12 way , double door , electrical 15 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 16 way, double door , electrical 16 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 6 way ( 4 + 18 ) , double door , electrical 17 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way ( 4 + 24 ) , double door , electrical 18 supplying and fixing of following ways surface / recess mounting, vertical type, 415 v, tpn mcb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 a tinned copper bus bar, common neutral link, earth bar, din bar for mounting mcbs ( but without mcbs and incomer ) as required . ( note : vertical type mcb tpdb is normally usedwhere 3 phase outlets are required. ) 4 way ( 4 + 12 ) , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 63a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 100a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , l / f pvc sheathed / xlpe power cable in trench laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 95 sq. mm and upto 185 sq. mm , l / f pvc sheathed / xlpe power cable in trench 1 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 185 sq. mm and upto 400 sq. mm , l / f pvc sheathed / xlpe power cable over cable tray upto 35 sq. mm ( clamped with 1mm thick saddle ) , l / f pvc sheathed / xlpe power cable over cable tray 2 above 35 sq. mm and upto 95 sq. mm ( clamped with 25x3mm ms flat clamp ) , l / f pvc sheathed / xlpe power cable over cable tray 3 above 95 sq. mm and upto 185 sq. mm ( clamped with 25 / 40x3mm ms flat clamp ) , l / f pvc sheathed / xlpe power cable over cable tray 4 above 185 sq. mm and upto 400 sq. mm ( clamped with 40x3mm ms flat clamp ) , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 3.5c x 300 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 1 3.5c x 240 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 2 3.5c x 120 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 3 3.5c x 95 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 4 3.5c x 50 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 5 4c x 35 sqmm aluminium conductor cable a2xfy , cable tray supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 100 mm width x 50 mm depth x 1.6 mm thickness , cable tray 1 supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 300 mm width x 50 mm depth x 1.6 mm thickness , cable tray 2 supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 600 mm width x 62.5 mm depth x 2.0 mm thickness , cable tray “bends” supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.100 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 1 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.150 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 2 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.300 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 3 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.450 mm width x 50 mm depth x 2 mm thickness , cable tray “bends” 4 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.600 mm width x 62.5 mm depth x 2.0 mm thickness , mv cable supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 300 sqmm, aluminium conductor cable a2xfy , mv cable 1 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 240 sqmm, aluminium conductor cable a2xfy , mv cable 2 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 120 sqmm, aluminium conductor cable a2xfy , mv cable 3 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 95 sqmm, aluminium conductor cable a2xfy , earthing earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 1 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. , earthing 2 earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. , earthing 3 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 4 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , earthing 5 providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required. , earthing 6 providing and fixing earth bus of 50 mm x 5 mm copper strip on surface for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 4 supplying and fixing recess mounted 12 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 6 supply, installation, testing and commissioning of 400 mm sweep, 65w, blade material aluminium blades , speed & oscillation 3 speed, pull cord for speed and oscillation.air delivery minimum 72 m³ / min, speed minimun 1350 revolution per minute.suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , fiting & fixtures 8 supplying installation testing & commissioning ofb22 based 9w led 3 star bulb with 850 lumen, 6k color temperature including holder. , fiting & fixtures 9 supplying installation testing & commissioning of black painted extruded aluminium housing. green / red led’s mounted inside the housing. laser engraved signage matter on single / double acrylic sheet fixed on one side suitable for wall / ceiling / suspension type single / double sided display. in double sided version black paper is inserted. ni cd battery back up to 2 hrs. ( charged up to 8 10 hrs ) .mounting strings provided for pendent mounting operating voltage 150 280v ac ambient operating temperature. – 0 to 450c ingress protection – ip42.including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required.   220208 besl 03 led ssd wbb green 240 3 8wor220209 besl 03 led ssd wbb red 240 3 8wor220210 besl 03 led dsd wbb green 240 3 8wor220211 besl 03 led dsd wbb red 240 3 8w , fiting & fixtures 10 supply, installation, testing & erecting of ip66 bulkhead surface type lighting fixture 10w made up of pressure die cast aluminium housing and polyster powder coated die cast aluminium with high quality polycarbonate diffuser in opal finish for glare free light distribution.high efficiency long life led module with smd led package mounted on mcpcb with lumen efficacy of >95 lm / w with system lumen 950. powered by integral electronic led driver with apfc with low thd output short / open circuit protection. cct 5700, cri>80, system efficacy>90lm / w, thd<15%, pf>.95, ip66, ik 10, life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz.including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. cat ref: havells : hexaft10wled857ssymbopc or approved equivalent. , civil & misc works1 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. , civil & misc works2 providing and fixing h.t. danger notice plate of 250 mm x 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. , civil & misc works3 supplying and making cable route marker with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm x 60 cm at the bottom and 50 cm x 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. , civil & misc works4 supplying and fixing cable route marker with 10 cm x 10 cm x 5 mm thick g.i. plate with inscription there on, bolted / welded to 35 mm x 35 mm x 6 mm angle iron, 60 cm long and fixing the same in ground as required. , civil & misc works5 providing & fixing in position 1000 mm wide , electrical insulating rubber mats as per is 15652:2006, 2 mm thick, suitable up to 1.1 kv , fire retardant, no effect of acids, alkalis and transformer oils, moisture proof, high tensile strengthandtexture finish / cloth impression ( anti slip , marking on top ) , civil & misc works6 supply & fixing shock treatment chart duly mounted on a wooden frame with 5 mm thick glass as required ( approx front area 1.20 sq metre ) , 40 kvaups supplying, installation, testing and commissioningof online double conversion fully microprocessor based , indoor type, compact ups system of following rating with igbt based pwm technology to achieve thd < 3% and input power factor of greater than 0.95 at 50% loading, suitable for three phase ac input voltage 380 v to 440 v, 50 hz +3% / 3 % and three phase ac output voltage 415 ± 1% volts & frequency 50 ± 0.5 hz , inbuilt isolation transformer, necessary vrla batteries of suitable size having 30 minutes back up time , mounting rack including and suitable size connecting cable ( for ups to battery and battery to battery ) , static and maintenance bypass switch, snmp card for rs232 / ethernet ip computability for operation and monitoring etc. with all components as mentioned , specifications, complete as required.note : concerning vendor needs to furnish the battery sizing calculations at the time of ga approval and battery size has to be as per the approved ga drawing. , external lighting 1 supply and erection of 4 metre height hot dipgalvanized octagonal street light pole with followingarm with top dia 70 mm and bottom dia a / f 130 mm, made of 3 mm thick sheet along with base plate of size220 x 220 x 12 mm , small door opening for junctionbox mounting with mcb & connector, cement concreteof 1:3:6 including excavation, refilling and suitable sizefoundation bolts with template and all complete jobasrequired. ( but without pole collar ) single arm , external lighting 2 supplying and fixing 40 / 45 watt led type street lightwith die cast aluminium housing for ingress protectionof ip65 and complete with all accessories etc, onpole / building including connection with fr pvcinsulated copper conductor cable and earthing thebody etc. as required. , ip based cctv system 1 sitc of 2 megapixel @ 25fps, h.265 ip bullet camera, 1 / 2.9 cmos with 2.8~12mm varifocal lens, 0 lux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 2 sitc of 2 megapixel @ 25fps, h.265 ip dome camera, 1 / 2.9 cmos with 3.6 fixed mm 0 lux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 3 sitc of 2 megapixel @ 25fps, ptz camera h.265 ip dome camera, 1 / 2.9 cmos with 2.6 fixed lenslux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 4 sitc of 32ch 4k ivr , h.265 / h.264 • 1080p real time • 4k display • dual lan • 8x hdd • raid •web plugin free h.265 / h.264 compression technology 4k display for clear monitoring up to 1080p 16ch decoding ability smart search ii smart vca event searchsupport raid 0, 1, 5 supported to prevent from recording data loss browsers supported: ie , smart functions : target count, electric fence, face detection, humaniod detection, retrograde detection, leave position detectio output, local & network backup etc. complete as required. , cctv 5 sitc of harddiskdrive8tb, 24 / 7surveillance category only complete etc as required.etc.all complete , cctv 6 sitc of 55 led narrow bazel for monitoring for nvr server etc. all complete. , cctv 7 sitc of rj 45 outlets near the cameras etc. all complete. etc. all complete. , cctv 8 sitc of cat 6 patch cords 1 meter high quality four pair twisted stranded cable terminated with rj45 modular plugs at both the ends. , signage 1 providing & fixing of building direction signage mounted on pole, with pole of 100x100mm shs ( square hollow section ) of height of 5600mm, and sign size of 900x1050, sign made of aluminiu c section of 60mm with internal framing to support the frame in ms tubes hollow section, frame work duly painted with anti rust coatings, with facia of 3mm thick exterior grade aluminium composite panel, cladded with uv cured digital printed retroreflective sheet of 3m make, and back panel of 3mm exterior grade acp, all pipes to be painted in approved color. cost shall includecost towards installation, including excuvation and filling up with specified pcc and fixing of foundation bolts as specified, also it shall include the designing charges.all complete as per direction by engineer in charge. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , 2 tr air conditioning 1 split ac ( inverter model ) : supply, installation, testing, commissioning of split type wall mounted air conditioning units of following capacity including inddor, outdoor unit fitted with inverter based rotary compressor fitted with rotary compressor, copper condensor and first charge refrigent r410a / eco friendly green gas only, all complete including all electrical connections to the electrical power supply system of the building, includingbut not limited to supply of all electrical plugs, etc., as necessary, lengthening of all electrical wires of ac units ( both indoor and outdoor ) , drain pipe andincluding suitable voltage stabilisers, etc. so as to place them in a concealed manner in the desired position. the copper pipes and electrical cables shall be concealed in approved manner and neatly run in straight lines in a workman like manner with proper supports. complete supply and installation of split2 tr star rating 3 star , refrigerant piping copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 25 mm od, wall thickness >= 1.2 mm ( insulation 19 mm thick ) , refrigerant piping 1 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 19.1 mm od, wall thickness >= 1.0 mm ( insulation 13 mm thick ) , refrigerant piping 2 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 15.9 mm od, wall thickness >= 0.8 mm ( insulation 13 mm thick ) , refrigerant piping 3 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 9.5 mm od, wall thickness >= 0.8 mm ( insulation 13 mm thick ) , drain piping providing and fixing of cpvc 6 kg / cm2 drainpiping complete with fittings, supports, 6 mm thick closed cell elastomeric insulation as per specifications and drawings. 20 mm , drain piping 1 providing and fixing of cpvc 6 kg / cm2 drainpiping complete with fittings, supports, 6 mm thick closed cell elastomeric insulation as per specifications and drawings. 32 mm , main oxygen manifold supply, installation, testing and commissioning of following gas manifold system ( excluding cylinders ) . the manifold is configured for designed numbers of cylinders and is suitable to withstand a pressure of 145 kg / cm2, along withhigh pressure copper annealed tail pipes with end brass adapter suitable for cylinders and manifold. top frame comprising of high pressure copper pipes of size 1 / 2” nb x 15swg with high pressure brass fittings made of high tensile brass and connections through nonreturn valves, the design of middle and bottomframes is provided to fit both round and flat bottom cylinders safely. the manifold is tested ( hydraulically ) at 3500 psig. ( it should be ce and iso 13485 certified ) mani fold oxygen manifold 6 + 6 cylinder banks complete with nrv, middle frame, bottom frame with ce marked, , emergency manifold emergency oxygen manifold 01 + 01 cylinder emergency manifold with complete regulator, nrv, middle frame & bottom frame, , control panelfor oxygen fully automatic three port control panel for oxygen supply, installation, testing and commissioning of automatic manifold control panel would provide a duty or standby gas supply from two cylinder banks with automaticchangeover the manifold indicates local status and has a remote indicator facility. automaticmanifold control panel would be designed to supply the mgps with a constant pressure supply via a control panel form two equal banks of cylinders and the changeover from the ‘duty’ to the ‘standby’ bank of cylinders would beautomatic. automatic changeover from the duty to the standby bank would occur at a cylinder pressure that will ensure the maximum usage of the contents of the duty bank. the changeover unit would be provided with monitoring todetect and display: duty bank operating, duty bank empty, standby bank operating, and standby bank below 10 % when the duty bank is empty, reserve bank low, pipeline pressure fault. there would be facility to connect liquidoxygen supply ( i.e. three port control panel ) ( it should be ce and iso 13485 certified ) fully automatic three port control panel for oxygen , emergency manifold line regulator emergency manifold line regulator supply, installation, testing and commissioning of emergency manifold line regulator i n p u t p r e s s u r e 1 5 0 k g / c m 2 working pressure 4 kg / cm2 it should be ce and iso 13485 certified.oxygen input pressure 150 kg / cm2 working pressure 4 kg / cm2capacity : 1500 lpm , cylinderconnectingpipe ( pig tail ) supply, installation, testing and commissioning of cylinder connecting pipe ( pig tail ) made up of flexible ss hose with safety cord 5 / 8 inch bsp gland nut and one side 1 / 2 inch bsp internal threads having one meter length. ( oxygen 24 , n2o 10, co2 4 ) , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , medical air ( 4 bar ) outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve, supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified.42mm , isolation valve 2 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 28mm , isolation valve 3 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 22mm , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness , pipeline 4 medical grade copper pipeline ( in mtrs. ) as per en 13348, 28 mm ( od ) x 0.9 mm thickness , pipeline 5 medical grade copper pipeline ( in mtrs. ) as per en 13348, 42 mm ( od ) x 1.2 mm thickness , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 2268 mm x ( w ) 922 mm x ( h ) 610 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , paediatric bed with mattress paediatric bed of overall sizes in mm: 1500 ( l ) x 850 ( w ) x 1210 ( h ) flat single section bed with grille frame on 4 sides.suitable for children up to 12 years.drop down grill frame on both sides for protection of the patient.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral white , bed side locker type i over all dimension :402mmlx422mm wx840mm ht .locker should have one cabinet and one drawer unit .both provided with cam lock .there should be gap between drawer and unit to keep general items for frequesnt use castors are provided for easy handling .drawer made up of crca sheet 1 mm thick and has ball slide for easy operation .top ss 304 sheet 0.8 mm thick castors 50 mmdia , hamdle abs ..powder coating of epoxy polyester , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , strecher on trolley type i 2005mm ( l ) x666mm ( w ) x827mm ( h ) .the trolley should be made of 31.75 and 25.4 mm dia 1.6 mm thick erw tube.holder for stretcher should be made up of mild steel.castor should be of 200 mm dia , diagonal locking castor.stretcher should be made up oferw tubeof dia 25.4 mm and thickness 1.6 mm.top sheet should be made of crca sheetof thickness 1.2 mm with contour shape to accommodate patient.iv pole holder should be made ofms .maximum safe work load should be 135 kg.to ensure qood quality welding co2 argonprocess should be adhered to.all metal componentsshould be pre treated with zinc phosphating in 9 tank porcess and then powder coated with anti microbialepoxy polyster powder coating.goods should be supplied in knocked down construction to reduce carbon emission. performance test :proof loading test , cycle tests , impact test, salt spray test, castor break test, the manufacturer should compilant with iso 9001, 14001, 13485, ohsas 1800 and ce certification. , doctor desk type x s / f / f executive table main desk should be of dimesion : 1350w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. side panels : ( black ) made form 18mm thick plt with pvc lipping.modesty panel : made form 18mm thick plt with pvc lipping. bigger upper panel in black and smaller lower panel in white cedar. made from 18mm thick plt with pvc lipping. mobile pedestal : one box and one filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , chair type iii s / f / f executive chair1 ) seat / back assembly: the seat and back are made up of 1.2 cm. thick hot pressed plywood, upholstered withfabric upholstery covers and moulded polyurethane foam. the back foam is designed with contoured lumbar support for extra comfort. the seat has extra thick foam on front edge to give comfort to popliteal area.high back size : 47.5 cm ( w ) x 69.5 cm ( h ) seat size : 47.0 cm. ( w ) x 48.0 cm. ( d ) 2 ) polyurethane foam: the polyurethane foam is moulded with density = 45 + / 2 kg / m 3and hardness = 20 + / 2at 25% compression. 3 ) armrests: the one piece armrests are injection moulded from black co polymer polypropylene. 4 ) center tilt synchro mechanism : the mechanism is designed with the following features:• 360 revolving type. • upright position locking. • tilt tension adjustment.• seat / back tilting ratio of 1:3 ( 60 seat tilt / 180 back tilt ) . 5 ) pneumatic height adjustment : the pneumatic height adjustment has anadjustment stroke of 12.0 cm. 6 ) telescopic bellow assembly : the bellow is 3 piece telescopic type and injection moulded in black polypropylene. 7 ) pedestal assembly : . , staff / visitor chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck .3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement.mx load bearing capacity should be 10 kg. , hospital curtain tracks & i.v. tree system supply installation testing & commissioning of cubical tracks system made of powder coated aluminium alloy, stain free polyster fabric , water repellent curtains , smooth movement , non sticking runnner with stainless steel hooks made from mirror finish stainless steel , adjustable height with all accessories. total quantity : 1...

Health And Family Welfare Department - Bihar

30457511 bids are invited for pile boring, providing and installation bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using direct mud circulation ( dmc ) or bailer and chisel technique by tripod and mechanical winch machine all complete, including removal of excavated earth with all its lifts and leads ( length of pile for payment shall be measured up to bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , upvc door providing and fixing of factory made upvc white colour casement door, upvc multichambered extruted frame, sash and mullion profile. frame duly reinforced with 1.2mm gi section box tpe chamber and sash with 1.5mm thick gi section ( ± 0.2mm ) based on wind load calculations ( shape and size according to upvc profiles ) , appropiate dimentions of upvc extruded glazing bead, epdm gasket ( k / o type ) , seperate drainage system, ss34 grade friction hinges 2d / 3d plate hinges, zinc alloy ( white powder coated ) casement handle, gi fastener 8x100 mm size for fixing frame to finish wall, plastic packer and caps and necessary steel screws etc.profile of frame and sash shall be metered cut and fusion welded at all corners, mullion shall be also fusion welded / joined mechanically including drilling of holes for fixing hardware and drainage of water etc. after fixing of frames , gap between frame and adjascent wall shall be filled with pu foaam / backer rod required size and the approved quantity. after that sealed with weather proof silicon sealant at both side, all complete as per approved drawing and direction of eic , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 1 providing and laying vitrified floor tiles in different sizes ( thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including grouting the joints with white cement and matching pigments etc., complete. size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge :flamed finish granite stone slab jet black, cherry red, elitebrown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item ( galvanised@80gsm ) 50 mm long 8mmouter diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’ , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975. the wind load shall be as per provisions of is 875 ( part iii ) . lgsfs frame shall be designed as per is: 801 using commercially available software such as frame cad pro 11.7 / staad pro v8i / architekv2.5.16 / revit architecture 2011 or equivalent. proper usage of connection accessories like heavy duty tension ties, light duty hold ons, twist straps ( to connect truss with wall frames ) , strong tie, tie rod, h brackets, boxing sections, l shaped angles for better structural stability. the framing section shall be cold form c type having minimum web depth 89 mm x 39mm flange x 11mm lip in required length as per structural design requirement duly punched with dimple / slot at required locations as per approved drawings. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm and. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , face panel providing and fixing in all exterior face panels breathable vapour barrier underneath the cementfiber board as per national building code 2009 complete as per direction of engineer in charge. , lap siding supplying and installation of moisture resistant / fire resistantlap siding 8 mm thick and width as per standard sizes made ofiber cement board with embossed decorative finish to give pleasing exterior fixed horizontally with staggered joints including minimum over lapof 32 mm external cement fibre boardconforming to is 14862:2000 offixed with self drilling / taping screws / fastners of approved make. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1 new work ( two or more coats ) over and including water tinnable priming coat with cement primer , ex. paint finishing walls with textured exterior paint of required shade : new work ( two or more coats applied @ 3.28 ltr / 10 sqm ) over and including priming coat of exterior primer applied @ 2.20kg / 10 sqm sqm , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel 1 steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , road providing and laying c.c. pavement of mix m 25 with ready mixed concrete from batching plant. the ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc.complete as per specifications and directions of engineer in charge. ( the panel shuttering work shall be paid for separately ) . ( note: cement content considered in this item is @ 330 kg / cum. excess / less cement used as per design mix is payable / recoverableseparately ) . , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 1 providing & fixing stone slab table rubbed, edges rounded and polished of size 75 x 50cm deep and 1.8 cm thick fixed in urinal patitions by cutting chase of appropriate width with chase cutter and embedding the stone in chase with epoxy grout or with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregste 6mm nominal size ) as per engineer in charge and finished smooth white agaria marble stone , phe 2 providing and fixing salem stainless steel a isi 304 ( 18 / 8 ) kitchen sink as per is: 13983 with ci brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required. kitchen sink with drain board510x1040mm bowl depth 200mm. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing:rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixturescomplete, including cutting and making good the walls andlevel whitep.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings andfloors wherever required :white vitreous china orissa pattern w.c. pan of size580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 9 providing and fixing cp brass 32mm size bottle trap of approved quality & make and as per the direction of engineer in charge.. ( sink & urinal ) , phe 10 providing & fixingptmt towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealedfittings arrangement of approved quality and colour weighing not less than 88 gms , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size 660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 15 providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water ( 250 ml & 500 ml consumption ) , having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of engineer in charge.. , phe 16 providing & fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. , phe 17 providing and fixing white vitreous china laboratory sink with c.i. brackets, c.p. brass chain with rubber plug, 40 mm c.p brass waste and 40mm c.p. brass trap with necessary c.p. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required :size 600x450x200 mm , phe 18 providing and fixing cp brass single lever telephonic wall mixer of quality & make as approved by engineer in charge . a ) 15 mm nominal dia. , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 21 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 24 two or more coats on new work over an under coat ofsuitable shade with ordinary paint of approved brand andmanufacturetwo more coast on new work , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm.clear depth and 250mm apron including cost of e / w. involved with 75mmcement concrete ( 1:4:8 ) over one brick designation 100 a flat soling inproper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 8 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia. exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 11 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 450 mm dia rcc pipe , ex. phe 12 inside size 120x90 cm and 90 cm deep including c.i. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg ) :with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , ex. phe 13 providing and fixing square mouth sw gully trap grade ‘a’ complete ci grating brick masonry chamber with bricks of class designation 75 and water tight ci cover with frame of 300 x 300 mm size ( inside ) the weight of cover to be not less than 13.00 kg and frame to be not less than 5 kg. as per standard design. ( cover min. 4.5 kg & frame min.2.7 kg ) 180x150 mm size p type with fps bricks , ex. phe 14 constructing masonry chamber 30x30x50 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement:4 coarce sand ) for stop cock complete with c.i. surface box 100x100x75mm ( inside ) with locking arrangement and rcc top slab 1:2:4 mix ( 1 cement : 2 corase sand: 4 graded stonr aggregate 20mm nominal size ) necessary excavation foundation concret 1:5:10 ( 1 cement:5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortor 1:3 ( 1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design. , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , ex. phe 16 structual steel work welded in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. , ex. phe 17 making connection of gi distribution branch with gi main of 50 80mm nominal bore by providing and fixing tee, including cutting and threading the pipe etc. complete. , rain water harvesting 1 boring / drilling bore well of required dia for casing / strainer pipe, bysuitable method prescribed in is:2800 ( part i ) , including collecting sample from different strata , preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90m depth below ground level.300 mm dia , rain water harvesting 2 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150mm nominal size dia , rain water harvesting 3 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well screen ( rms ) pipes with ribs, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150 mm nominal size dia , rain water harvesting 4 supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 5 supplying, filling, spreading & levelling gravel of size range 5mm to 10mm, in recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 7 providing and fixing bail plug / bottom plug of required dia to the bottom of pipe assembly of tube well as per is:2800 ( part i ) . 100 mm dia , rain water harvesting 8 making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and s.w. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , rain water harvesting 9 constructing soak pit 1.20x1.20x1.20 m filled with brickbats including s.w. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , tubewell 1 boring / drilling bore well of required dia for casing / strainer pipe, bysuitable method prescribed in is:2800 ( part i ) , including collecting sample from different strata , preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90m depth below ground level.300 mm dia , tubewell 2 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150mm nominal size dia , tubewell 3 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.100mm nominal size dia , tubewell 4 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well screen ( rms ) pipes with ribs, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.100 mm nominal size dia , tubewell 5 supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , tubewell 6 providing and fixing bail plug / bottom plug of required dia to the bottom of pipe assembly of tube well as per is:2800 ( part i ) . 100 mm dia , submersible pump 35m deep boring with casing and pipe. supply of pipe etc supplying & installation of suitable 2hp submersible pump b.s or k.s.bor equivalent make with finolex cable 1x3x2.5 squmm ( upto 50mtr ) withflexible conduit 25mm dia, electrical out door pannel with required electrical fitting such as mcb of 0 25amp ( havell or indocopp or mds make ) , volt & ampere meter ( ae make ) , single phase preventer ( minilac or vsp 1 make ) starter ( l&t or bch make ) etc of approved make, 40mm hdpe pipe ( 25 mtr ) and all accessories complete as per requirement of site. , water purifier and cooler 1 fitting and fixing single faucet storage type water cooler ( size 461 mm wide x 582 mm deep x 1217 mm height, weight 46 kg ) fully stainless body having storage capacity of 40 ltrs, cooling capacity of 40 ltrs. / hr. with hermetic type compressor, gas cooled motor equipped with over load protector, condensor for propeller type, thermostat autometically controlled temperature, refrigerent r 22, 230 volt, single phase 50 hertz, maximum current 2.3 amp including plug top and electrical lead wire connection upto 3 metres from the cooler, water inlet and drain out connections complete in all respects of voltas model no 40 / 40 tushar pss type or similar type of approved make. , water purifier and cooler 2 fitting and fixing water purifier for drinking purpose of capacity 6 litres / min, 5 purification system with reverse osmosis system with ultra ventilated membrane, tds500 to 2000 mgl / ppm, auto shut off with microswitch float manual flush facility, tds reduction 90% having automatic backwash system with filteration unit along with all accessories including plug top and electrical lead wire connection upto 3 metres from the purifier, water inlet and drain out connections complete in all respects similar to aquaguard or similar approved make ( model aquasure elegant ro water purifier of size width 360 mm x height 430 mm x depth 235 mm and weight 8.5 kg ) . , fire extinguisher 1 providing and fixing carbon di oxide type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. capacity 4.5 kg. , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 6.0 kg. , electrical 1 wiring for light point / fan point / exhaust fan point / call bellpoint with 1.5 sq.mm frls pvc insulated copper conductorsingle core cable in surface / recessed steel conduit, withmodular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. group c , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , pvc conduit 1 supplying and fixing of following sizes of medium class 20mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , pvc conduit 2 supplying and fixing of following sizes of medium class 32mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , pvc conduit 3 supplying and fixing of following sizes of medium class 50mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , electrical 4 wiring for light / power plug with 2x4 sq. mm frls pvcinsulated copper conductor single core cable in surface / recessed conduit alongwith 1 no. 4 sq. mm frls pvcinsulated copper conductor single core cable for loop earthingas required. , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 4 x 6 sq. mm + 2 x 6 sq. mm earth wire , wiring frls pvc insulated copper conductor 4 4 x 10 sq. mm + 2 x 6 sq. mm earth wire , wiring frls pvc insulated copper conductor 5 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 1 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 3 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 4 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 2 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 3 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 4 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 5 telephone socket outlet , s / f modular switch / socket on the existing modular plate 6 tv antenna socket outlet , s / f modular switch / socket on the existing modular plate 7 bell push , electrical 5 supplying & fixing suitable size gi box wih modular plate and cover in front on surface or in recess including providing and fixing 25 a modular socket outlet and 25 a modular sp mcb, “c” curve including connections, painting etc. as required. ( for ac / geyser ) , electrical 6 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface / recessed steel / pvc conduit as required. , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 11 supplying and fixing 20 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. , electrical 12 supplying and fixing 30 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , electrical 14 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 12 way , double door , electrical 15 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 16 way, double door , electrical 16 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 6 way ( 4 + 18 ) , double door , electrical 17 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way ( 4 + 24 ) , double door , electrical 18 supplying and fixing of following ways surface / recess mounting, vertical type, 415 v, tpn mcb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 a tinned copper bus bar, common neutral link, earth bar, din bar for mounting mcbs ( but without mcbs and incomer ) as required . ( note : vertical type mcb tpdb is normally usedwhere 3 phase outlets are required. ) 4 way ( 4 + 12 ) , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 63a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 100a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , l / f pvc sheathed / xlpe power cable in trench laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 95 sq. mm and upto 185 sq. mm , l / f pvc sheathed / xlpe power cable in trench 1 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 185 sq. mm and upto 400 sq. mm , l / f pvc sheathed / xlpe power cable over cable tray upto 35 sq. mm ( clamped with 1mm thick saddle ) , l / f pvc sheathed / xlpe power cable over cable tray 2 above 35 sq. mm and upto 95 sq. mm ( clamped with 25x3mm ms flat clamp ) , l / f pvc sheathed / xlpe power cable over cable tray 3 above 95 sq. mm and upto 185 sq. mm ( clamped with 25 / 40x3mm ms flat clamp ) , l / f pvc sheathed / xlpe power cable over cable tray 4 above 185 sq. mm and upto 400 sq. mm ( clamped with 40x3mm ms flat clamp ) , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 3.5c x 300 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 1 3.5c x 240 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 2 3.5c x 120 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 3 3.5c x 95 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 4 3.5c x 50 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 5 4c x 35 sqmm aluminium conductor cable a2xfy , cable tray supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 100 mm width x 50 mm depth x 1.6 mm thickness , cable tray 1 supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 300 mm width x 50 mm depth x 1.6 mm thickness , cable tray 2 supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 600 mm width x 62.5 mm depth x 2.0 mm thickness , cable tray “bends” supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.100 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 1 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.150 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 2 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.300 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 3 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.450 mm width x 50 mm depth x 2 mm thickness , cable tray “bends” 4 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.600 mm width x 62.5 mm depth x 2.0 mm thickness , mv cable supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 300 sqmm, aluminium conductor cable a2xfy , mv cable 1 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 240 sqmm, aluminium conductor cable a2xfy , mv cable 2 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 120 sqmm, aluminium conductor cable a2xfy , mv cable 3 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 95 sqmm, aluminium conductor cable a2xfy , earthing earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 1 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. , earthing 2 earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. , earthing 3 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 4 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , earthing 5 providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required. , earthing 6 providing and fixing earth bus of 50 mm x 5 mm copper strip on surface for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 4 supplying and fixing recess mounted 12 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 6 supply, installation, testing and commissioning of 400 mm sweep, 65w, blade material aluminium blades , speed & oscillation 3 speed, pull cord for speed and oscillation.air delivery minimum 72 m³ / min, speed minimun 1350 revolution per minute.suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , fiting & fixtures 8 supplying installation testing & commissioning ofb22 based 9w led 3 star bulb with 850 lumen, 6k color temperature including holder. , fiting & fixtures 9 supplying installation testing & commissioning of black painted extruded aluminium housing. green / red led’s mounted inside the housing. laser engraved signage matter on single / double acrylic sheet fixed on one side suitable for wall / ceiling / suspension type single / double sided display. in double sided version black paper is inserted. ni cd battery back up to 2 hrs. ( charged up to 8 10 hrs ) .mounting strings provided for pendent mounting operating voltage 150 280v ac ambient operating temperature. – 0 to 450c ingress protection – ip42.including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required.   220208 besl 03 led ssd wbb green 240 3 8wor220209 besl 03 led ssd wbb red 240 3 8wor220210 besl 03 led dsd wbb green 240 3 8wor220211 besl 03 led dsd wbb red 240 3 8w , fiting & fixtures 10 supply, installation, testing & erecting of ip66 bulkhead surface type lighting fixture 10w made up of pressure die cast aluminium housing and polyster powder coated die cast aluminium with high quality polycarbonate diffuser in opal finish for glare free light distribution.high efficiency long life led module with smd led package mounted on mcpcb with lumen efficacy of >95 lm / w with system lumen 950. powered by integral electronic led driver with apfc with low thd output short / open circuit protection. cct 5700, cri>80, system efficacy>90lm / w, thd<15%, pf>.95, ip66, ik 10, life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz.including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. cat ref: havells : hexaft10wled857ssymbopc or approved equivalent. , civil & misc works1 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. , civil & misc works2 providing and fixing h.t. danger notice plate of 250 mm x 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. , civil & misc works3 supplying and making cable route marker with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm x 60 cm at the bottom and 50 cm x 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. , civil & misc works4 supplying and fixing cable route marker with 10 cm x 10 cm x 5 mm thick g.i. plate with inscription there on, bolted / welded to 35 mm x 35 mm x 6 mm angle iron, 60 cm long and fixing the same in ground as required. , civil & misc works5 providing & fixing in position 1000 mm wide , electrical insulating rubber mats as per is 15652:2006, 2 mm thick, suitable up to 1.1 kv , fire retardant, no effect of acids, alkalis and transformer oils, moisture proof, high tensile strengthandtexture finish / cloth impression ( anti slip , marking on top ) , civil & misc works6 supply & fixing shock treatment chart duly mounted on a wooden frame with 5 mm thick glass as required ( approx front area 1.20 sq metre ) , 40 kvaups supplying, installation, testing and commissioningof online double conversion fully microprocessor based , indoor type, compact ups system of following rating with igbt based pwm technology to achieve thd < 3% and input power factor of greater than 0.95 at 50% loading, suitable for three phase ac input voltage 380 v to 440 v, 50 hz +3% / 3 % and three phase ac output voltage 415 ± 1% volts & frequency 50 ± 0.5 hz , inbuilt isolation transformer, necessary vrla batteries of suitable size having 30 minutes back up time , mounting rack including and suitable size connecting cable ( for ups to battery and battery to battery ) , static and maintenance bypass switch, snmp card for rs232 / ethernet ip computability for operation and monitoring etc. with all components as mentioned , specifications, complete as required.note : concerning vendor needs to furnish the battery sizing calculations at the time of ga approval and battery size has to be as per the approved ga drawing. , external lighting 1 supply and erection of 4 metre height hot dipgalvanized octagonal street light pole with followingarm with top dia 70 mm and bottom dia a / f 130 mm, made of 3 mm thick sheet along with base plate of size220 x 220 x 12 mm , small door opening for junctionbox mounting with mcb & connector, cement concreteof 1:3:6 including excavation, refilling and suitable sizefoundation bolts with template and all complete jobasrequired. ( but without pole collar ) single arm , external lighting 2 supplying and fixing 40 / 45 watt led type street lightwith die cast aluminium housing for ingress protectionof ip65 and complete with all accessories etc, onpole / building including connection with fr pvcinsulated copper conductor cable and earthing thebody etc. as required. , ip based cctv system 1 sitc of 2 megapixel @ 25fps, h.265 ip bullet camera, 1 / 2.9 cmos with 2.8~12mm varifocal lens, 0 lux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 2 sitc of 2 megapixel @ 25fps, h.265 ip dome camera, 1 / 2.9 cmos with 3.6 fixed mm 0 lux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 3 sitc of 2 megapixel @ 25fps, ptz camera h.265 ip dome camera, 1 / 2.9 cmos with 2.6 fixed lenslux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 4 sitc of 32ch 4k ivr , h.265 / h.264 • 1080p real time • 4k display • dual lan • 8x hdd • raid •web plugin free h.265 / h.264 compression technology 4k display for clear monitoring up to 1080p 16ch decoding ability smart search ii smart vca event searchsupport raid 0, 1, 5 supported to prevent from recording data loss browsers supported: ie , smart functions : target count, electric fence, face detection, humaniod detection, retrograde detection, leave position detectio output, local & network backup etc. complete as required. , cctv 5 sitc of harddiskdrive8tb, 24 / 7surveillance category only complete etc as required.etc.all complete , cctv 6 sitc of 55 led narrow bazel for monitoring for nvr server etc. all complete. , cctv 7 sitc of rj 45 outlets near the cameras etc. all complete. etc. all complete. , cctv 8 sitc of cat 6 patch cords 1 meter high quality four pair twisted stranded cable terminated with rj45 modular plugs at both the ends. , signage 1 providing & fixing of building direction signage mounted on pole, with pole of 100x100mm shs ( square hollow section ) of height of 5600mm, and sign size of 900x1050, sign made of aluminiu c section of 60mm with internal framing to support the frame in ms tubes hollow section, frame work duly painted with anti rust coatings, with facia of 3mm thick exterior grade aluminium composite panel, cladded with uv cured digital printed retroreflective sheet of 3m make, and back panel of 3mm exterior grade acp, all pipes to be painted in approved color. cost shall includecost towards installation, including excuvation and filling up with specified pcc and fixing of foundation bolts as specified, also it shall include the designing charges.all complete as per direction by engineer in charge. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , 2 tr air conditioning 1 split ac ( inverter model ) : supply, installation, testing, commissioning of split type wall mounted air conditioning units of following capacity including inddor, outdoor unit fitted with inverter based rotary compressor fitted with rotary compressor, copper condensor and first charge refrigent r410a / eco friendly green gas only, all complete including all electrical connections to the electrical power supply system of the building, includingbut not limited to supply of all electrical plugs, etc., as necessary, lengthening of all electrical wires of ac units ( both indoor and outdoor ) , drain pipe andincluding suitable voltage stabilisers, etc. so as to place them in a concealed manner in the desired position. the copper pipes and electrical cables shall be concealed in approved manner and neatly run in straight lines in a workman like manner with proper supports. complete supply and installation of split2 tr star rating 3 star , refrigerant piping copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 25 mm od, wall thickness >= 1.2 mm ( insulation 19 mm thick ) , refrigerant piping 1 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 19.1 mm od, wall thickness >= 1.0 mm ( insulation 13 mm thick ) , refrigerant piping 2 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 15.9 mm od, wall thickness >= 0.8 mm ( insulation 13 mm thick ) , refrigerant piping 3 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 9.5 mm od, wall thickness >= 0.8 mm ( insulation 13 mm thick ) , drain piping providing and fixing of cpvc 6 kg / cm2 drainpiping complete with fittings, supports, 6 mm thick closed cell elastomeric insulation as per specifications and drawings. 20 mm , drain piping 1 providing and fixing of cpvc 6 kg / cm2 drainpiping complete with fittings, supports, 6 mm thick closed cell elastomeric insulation as per specifications and drawings. 32 mm , main oxygen manifold supply, installation, testing and commissioning of following gas manifold system ( excluding cylinders ) . the manifold is configured for designed numbers of cylinders and is suitable to withstand a pressure of 145 kg / cm2, along withhigh pressure copper annealed tail pipes with end brass adapter suitable for cylinders and manifold. top frame comprising of high pressure copper pipes of size 1 / 2” nb x 15swg with high pressure brass fittings made of high tensile brass and connections through nonreturn valves, the design of middle and bottomframes is provided to fit both round and flat bottom cylinders safely. the manifold is tested ( hydraulically ) at 3500 psig. ( it should be ce and iso 13485 certified ) mani fold oxygen manifold 6 + 6 cylinder banks complete with nrv, middle frame, bottom frame with ce marked, , emergency manifold emergency oxygen manifold 01 + 01 cylinder emergency manifold with complete regulator, nrv, middle frame & bottom frame, , control panelfor oxygen fully automatic three port control panel for oxygen supply, installation, testing and commissioning of automatic manifold control panel would provide a duty or standby gas supply from two cylinder banks with automaticchangeover the manifold indicates local status and has a remote indicator facility. automaticmanifold control panel would be designed to supply the mgps with a constant pressure supply via a control panel form two equal banks of cylinders and the changeover from the ‘duty’ to the ‘standby’ bank of cylinders would beautomatic. automatic changeover from the duty to the standby bank would occur at a cylinder pressure that will ensure the maximum usage of the contents of the duty bank. the changeover unit would be provided with monitoring todetect and display: duty bank operating, duty bank empty, standby bank operating, and standby bank below 10 % when the duty bank is empty, reserve bank low, pipeline pressure fault. there would be facility to connect liquidoxygen supply ( i.e. three port control panel ) ( it should be ce and iso 13485 certified ) fully automatic three port control panel for oxygen , emergency manifold line regulator emergency manifold line regulator supply, installation, testing and commissioning of emergency manifold line regulator i n p u t p r e s s u r e 1 5 0 k g / c m 2 working pressure 4 kg / cm2 it should be ce and iso 13485 certified.oxygen input pressure 150 kg / cm2 working pressure 4 kg / cm2capacity : 1500 lpm , cylinderconnectingpipe ( pig tail ) supply, installation, testing and commissioning of cylinder connecting pipe ( pig tail ) made up of flexible ss hose with safety cord 5 / 8 inch bsp gland nut and one side 1 / 2 inch bsp internal threads having one meter length. ( oxygen 24 , n2o 10, co2 4 ) , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , medical air ( 4 bar ) outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve, supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified.42mm , isolation valve 2 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 28mm , isolation valve 3 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 22mm , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness , pipeline 4 medical grade copper pipeline ( in mtrs. ) as per en 13348, 28 mm ( od ) x 0.9 mm thickness , pipeline 5 medical grade copper pipeline ( in mtrs. ) as per en 13348, 42 mm ( od ) x 1.2 mm thickness , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 2268 mm x ( w ) 922 mm x ( h ) 610 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , paediatric bed with mattress paediatric bed of overall sizes in mm: 1500 ( l ) x 850 ( w ) x 1210 ( h ) flat single section bed with grille frame on 4 sides.suitable for children up to 12 years.drop down grill frame on both sides for protection of the patient.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral white , bed side locker type i over all dimension :402mmlx422mm wx840mm ht .locker should have one cabinet and one drawer unit .both provided with cam lock .there should be gap between drawer and unit to keep general items for frequesnt use castors are provided for easy handling .drawer made up of crca sheet 1 mm thick and has ball slide for easy operation .top ss 304 sheet 0.8 mm thick castors 50 mmdia , hamdle abs ..powder coating of epoxy polyester , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , strecher on trolley type i 2005mm ( l ) x666mm ( w ) x827mm ( h ) .the trolley should be made of 31.75 and 25.4 mm dia 1.6 mm thick erw tube.holder for stretcher should be made up of mild steel.castor should be of 200 mm dia , diagonal locking castor.stretcher should be made up oferw tubeof dia 25.4 mm and thickness 1.6 mm.top sheet should be made of crca sheetof thickness 1.2 mm with contour shape to accommodate patient.iv pole holder should be made ofms .maximum safe work load should be 135 kg.to ensure qood quality welding co2 argonprocess should be adhered to.all metal componentsshould be pre treated with zinc phosphating in 9 tank porcess and then powder coated with anti microbialepoxy polyster powder coating.goods should be supplied in knocked down construction to reduce carbon emission. performance test :proof loading test , cycle tests , impact test, salt spray test, castor break test, the manufacturer should compilant with iso 9001, 14001, 13485, ohsas 1800 and ce certification. , doctor desk type x s / f / f executive table main desk should be of dimesion : 1350w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. side panels : ( black ) made form 18mm thick plt with pvc lipping.modesty panel : made form 18mm thick plt with pvc lipping. bigger upper panel in black and smaller lower panel in white cedar. made from 18mm thick plt with pvc lipping. mobile pedestal : one box and one filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , chair type iii s / f / f executive chair1 ) seat / back assembly: the seat and back are made up of 1.2 cm. thick hot pressed plywood, upholstered withfabric upholstery covers and moulded polyurethane foam. the back foam is designed with contoured lumbar support for extra comfort. the seat has extra thick foam on front edge to give comfort to popliteal area.high back size : 47.5 cm ( w ) x 69.5 cm ( h ) seat size : 47.0 cm. ( w ) x 48.0 cm. ( d ) 2 ) polyurethane foam: the polyurethane foam is moulded with density = 45 + / 2 kg / m 3and hardness = 20 + / 2at 25% compression. 3 ) armrests: the one piece armrests are injection moulded from black co polymer polypropylene. 4 ) center tilt synchro mechanism : the mechanism is designed with the following features:• 360 revolving type. • upright position locking. • tilt tension adjustment.• seat / back tilting ratio of 1:3 ( 60 seat tilt / 180 back tilt ) . 5 ) pneumatic height adjustment : the pneumatic height adjustment has anadjustment stroke of 12.0 cm. 6 ) telescopic bellow assembly : the bellow is 3 piece telescopic type and injection moulded in black polypropylene. 7 ) pedestal assembly : . , staff / visitor chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck .3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement.mx load bearing capacity should be 10 kg. , hospital curtain tracks & i.v. tree system supply installation testing & commissioning of cubical tracks system made of powder coated aluminium alloy, stain free polyster fabric , water repellent curtains , smooth movement , non sticking runnner with stainless steel hooks made from mirror finish stainless steel , adjustable height with all accessories. total quantity : 1...

Health And Family Welfare Department - Bihar

30456419 bids are invited for pile boring, providing and installation bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using direct mud circulation ( dmc ) or bailer and chisel technique by tripod and mechanical winch machine all complete, including removal of excavated earth with all its lifts and leads ( length of pile for payment shall be measured up to bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , upvc door providing and fixing of factory made upvc white colour casement door, upvc multichambered extruted frame, sash and mullion profile. frame duly reinforced with 1.2mm gi section box tpe chamber and sash with 1.5mm thick gi section ( ± 0.2mm ) based on wind load calculations ( shape and size according to upvc profiles ) , appropiate dimentions of upvc extruded glazing bead, epdm gasket ( k / o type ) , seperate drainage system, ss34 grade friction hinges 2d / 3d plate hinges, zinc alloy ( white powder coated ) casement handle, gi fastener 8x100 mm size for fixing frame to finish wall, plastic packer and caps and necessary steel screws etc.profile of frame and sash shall be metered cut and fusion welded at all corners, mullion shall be also fusion welded / joined mechanically including drilling of holes for fixing hardware and drainage of water etc. after fixing of frames , gap between frame and adjascent wall shall be filled with pu foaam / backer rod required size and the approved quantity. after that sealed with weather proof silicon sealant at both side, all complete as per approved drawing and direction of eic , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 1 providing and laying vitrified floor tiles in different sizes ( thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including grouting the joints with white cement and matching pigments etc., complete. size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge :flamed finish granite stone slab jet black, cherry red, elitebrown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item ( galvanised@80gsm ) 50 mm long 8mmouter diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’ , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975. the wind load shall be as per provisions of is 875 ( part iii ) . lgsfs frame shall be designed as per is: 801 using commercially available software such as frame cad pro 11.7 / staad pro v8i / architekv2.5.16 / revit architecture 2011 or equivalent. proper usage of connection accessories like heavy duty tension ties, light duty hold ons, twist straps ( to connect truss with wall frames ) , strong tie, tie rod, h brackets, boxing sections, l shaped angles for better structural stability. the framing section shall be cold form c type having minimum web depth 89 mm x 39mm flange x 11mm lip in required length as per structural design requirement duly punched with dimple / slot at required locations as per approved drawings. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm and. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , face panel providing and fixing in all exterior face panels breathable vapour barrier underneath the cementfiber board as per national building code 2009 complete as per direction of engineer in charge. , lap siding supplying and installation of moisture resistant / fire resistantlap siding 8 mm thick and width as per standard sizes made ofiber cement board with embossed decorative finish to give pleasing exterior fixed horizontally with staggered joints including minimum over lapof 32 mm external cement fibre boardconforming to is 14862:2000 offixed with self drilling / taping screws / fastners of approved make. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1 new work ( two or more coats ) over and including water tinnable priming coat with cement primer , ex. paint finishing walls with textured exterior paint of required shade : new work ( two or more coats applied @ 3.28 ltr / 10 sqm ) over and including priming coat of exterior primer applied @ 2.20kg / 10 sqm sqm , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel 1 steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , road providing and laying c.c. pavement of mix m 25 with ready mixed concrete from batching plant. the ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc.complete as per specifications and directions of engineer in charge. ( the panel shuttering work shall be paid for separately ) . ( note: cement content considered in this item is @ 330 kg / cum. excess / less cement used as per design mix is payable / recoverableseparately ) . , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 1 providing & fixing stone slab table rubbed, edges rounded and polished of size 75 x 50cm deep and 1.8 cm thick fixed in urinal patitions by cutting chase of appropriate width with chase cutter and embedding the stone in chase with epoxy grout or with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregste 6mm nominal size ) as per engineer in charge and finished smooth white agaria marble stone , phe 2 providing and fixing salem stainless steel a isi 304 ( 18 / 8 ) kitchen sink as per is: 13983 with ci brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required. kitchen sink with drain board510x1040mm bowl depth 200mm. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing:rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixturescomplete, including cutting and making good the walls andlevel whitep.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings andfloors wherever required :white vitreous china orissa pattern w.c. pan of size580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 9 providing and fixing cp brass 32mm size bottle trap of approved quality & make and as per the direction of engineer in charge.. ( sink & urinal ) , phe 10 providing & fixingptmt towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealedfittings arrangement of approved quality and colour weighing not less than 88 gms , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size 660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 15 providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water ( 250 ml & 500 ml consumption ) , having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of engineer in charge.. , phe 16 providing & fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. , phe 17 providing and fixing white vitreous china laboratory sink with c.i. brackets, c.p. brass chain with rubber plug, 40 mm c.p brass waste and 40mm c.p. brass trap with necessary c.p. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required :size 600x450x200 mm , phe 18 providing and fixing cp brass single lever telephonic wall mixer of quality & make as approved by engineer in charge . a ) 15 mm nominal dia. , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 21 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 24 two or more coats on new work over an under coat ofsuitable shade with ordinary paint of approved brand andmanufacturetwo more coast on new work , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm.clear depth and 250mm apron including cost of e / w. involved with 75mmcement concrete ( 1:4:8 ) over one brick designation 100 a flat soling inproper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 8 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia. exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 11 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 450 mm dia rcc pipe , ex. phe 12 inside size 120x90 cm and 90 cm deep including c.i. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg ) :with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , ex. phe 13 providing and fixing square mouth sw gully trap grade ‘a’ complete ci grating brick masonry chamber with bricks of class designation 75 and water tight ci cover with frame of 300 x 300 mm size ( inside ) the weight of cover to be not less than 13.00 kg and frame to be not less than 5 kg. as per standard design. ( cover min. 4.5 kg & frame min.2.7 kg ) 180x150 mm size p type with fps bricks , ex. phe 14 constructing masonry chamber 30x30x50 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement:4 coarce sand ) for stop cock complete with c.i. surface box 100x100x75mm ( inside ) with locking arrangement and rcc top slab 1:2:4 mix ( 1 cement : 2 corase sand: 4 graded stonr aggregate 20mm nominal size ) necessary excavation foundation concret 1:5:10 ( 1 cement:5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortor 1:3 ( 1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design. , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , ex. phe 16 structual steel work welded in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. , ex. phe 17 making connection of gi distribution branch with gi main of 50 80mm nominal bore by providing and fixing tee, including cutting and threading the pipe etc. complete. , rain water harvesting 1 boring / drilling bore well of required dia for casing / strainer pipe, bysuitable method prescribed in is:2800 ( part i ) , including collecting sample from different strata , preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90m depth below ground level.300 mm dia , rain water harvesting 2 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150mm nominal size dia , rain water harvesting 3 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well screen ( rms ) pipes with ribs, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150 mm nominal size dia , rain water harvesting 4 supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 5 supplying, filling, spreading & levelling gravel of size range 5mm to 10mm, in recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 7 providing and fixing bail plug / bottom plug of required dia to the bottom of pipe assembly of tube well as per is:2800 ( part i ) . 100 mm dia , rain water harvesting 8 making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and s.w. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , rain water harvesting 9 constructing soak pit 1.20x1.20x1.20 m filled with brickbats including s.w. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , tubewell 1 boring / drilling bore well of required dia for casing / strainer pipe, bysuitable method prescribed in is:2800 ( part i ) , including collecting sample from different strata , preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90m depth below ground level.300 mm dia , tubewell 2 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150mm nominal size dia , tubewell 3 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.100mm nominal size dia , tubewell 4 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well screen ( rms ) pipes with ribs, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.100 mm nominal size dia , tubewell 5 supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , tubewell 6 providing and fixing bail plug / bottom plug of required dia to the bottom of pipe assembly of tube well as per is:2800 ( part i ) . 100 mm dia , submersible pump 35m deep boring with casing and pipe. supply of pipe etc supplying & installation of suitable 2hp submersible pump b.s or k.s.bor equivalent make with finolex cable 1x3x2.5 squmm ( upto 50mtr ) withflexible conduit 25mm dia, electrical out door pannel with required electrical fitting such as mcb of 0 25amp ( havell or indocopp or mds make ) , volt & ampere meter ( ae make ) , single phase preventer ( minilac or vsp 1 make ) starter ( l&t or bch make ) etc of approved make, 40mm hdpe pipe ( 25 mtr ) and all accessories complete as per requirement of site. , water purifier and cooler fitting and fixing single faucet storage type water cooler ( size 461 mm wide x 582 mm deep x 1217 mm height, weight 46 kg ) fully stainless body having storage capacity of 40 ltrs, cooling capacity of 40 ltrs. / hr. with hermetic type compressor, gas cooled motor equipped with over load protector, condensor for propeller type, thermostat autometically controlled temperature, refrigerent r 22, 230 volt, single phase 50 hertz, maximum current 2.3 amp including plug top and electrical lead wire connection upto 3 metres from the cooler, water inlet and drain out connections complete in all respects of voltas model no 40 / 40 tushar pss type or similar type of approved make. , water purifier and cooler 1 fitting and fixing water purifier for drinking purpose of capacity 6 litres / min, 5 purification system with reverse osmosis system with ultra ventilated membrane, tds500 to 2000 mgl / ppm, auto shut off with microswitch float manual flush facility, tds reduction 90% having automatic backwash system with filteration unit along with all accessories including plug top and electrical lead wire connection upto 3 metres from the purifier, water inlet and drain out connections complete in all respects similar to aquaguard or similar approved make ( model aquasure elegant ro water purifier of size width 360 mm x height 430 mm x depth 235 mm and weight 8.5 kg ) . , fire extinguisher 1 providing and fixing carbon di oxide type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. capacity 4.5 kg. , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 6.0 kg. , electrical 1 wiring for light point / fan point / exhaust fan point / call bellpoint with 1.5 sq.mm frls pvc insulated copper conductorsingle core cable in surface / recessed steel conduit, withmodular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. group c , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , pvc conduit 1 supplying and fixing of following sizes of medium class 20mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , pvc conduit 2 supplying and fixing of following sizes of medium class 32mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , pvc conduit 3 supplying and fixing of following sizes of medium class 50mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , electrical 4 wiring for light / power plug with 2x4 sq. mm frls pvcinsulated copper conductor single core cable in surface / recessed conduit alongwith 1 no. 4 sq. mm frls pvcinsulated copper conductor single core cable for loop earthingas required. , wiring frls pvc insulated copper conductor 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 1 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 2 4 x 6 sq. mm + 2 x 6 sq. mm earth wire , wiring frls pvc insulated copper conductor 3 4 x 10 sq. mm + 2 x 6 sq. mm earth wire , wiring frls pvc insulated copper conductor 4 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 1 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 3 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 4 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 1 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 2 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 3 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 4 telephone socket outlet , s / f modular switch / socket on the existing modular plate 5 tv antenna socket outlet , s / f modular switch / socket on the existing modular plate 6 bell push , electrical 5 supplying & fixing suitable size gi box wih modular plate and cover in front on surface or in recess including providing and fixing 25 a modular socket outlet and 25 a modular sp mcb, “c” curve including connections, painting etc. as required. ( for ac / geyser ) , electrical 6 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface / recessed steel / pvc conduit as required. , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 11 supplying and fixing 20 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. , electrical 12 supplying and fixing 30 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , electrical 14 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 12 way , double door , electrical 15 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 16 way, double door , electrical 16 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 6 way ( 4 + 18 ) , double door , electrical 17 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way ( 4 + 24 ) , double door , electrical 18 supplying and fixing of following ways surface / recess mounting, vertical type, 415 v, tpn mcb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 a tinned copper bus bar, common neutral link, earth bar, din bar for mounting mcbs ( but without mcbs and incomer ) as required . ( note : vertical type mcb tpdb is normally usedwhere 3 phase outlets are required. ) 4 way ( 4 + 12 ) , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 63a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 100a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , l / f pvc sheathed / xlpe power cable in trench laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 95 sq. mm and upto 185 sq. mm , l / f pvc sheathed / xlpe power cable in trench 1 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 185 sq. mm and upto 400 sq. mm , l / f pvc sheathed / xlpe power cable over cable tray 2 upto 35 sq. mm ( clamped with 1mm thick saddle ) , l / f pvc sheathed / xlpe power cable over cable tray 3 above 35 sq. mm and upto 95 sq. mm ( clamped with 25x3mm ms flat clamp ) , l / f pvc sheathed / xlpe power cable over cable tray 4 above 95 sq. mm and upto 185 sq. mm ( clamped with 25 / 40x3mm ms flat clamp ) , l / f pvc sheathed / xlpe power cable over cable tray 5 above 185 sq. mm and upto 400 sq. mm ( clamped with 40x3mm ms flat clamp ) , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 3.5c x 300 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 1 3.5c x 240 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 2 3.5c x 120 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 3 3.5c x 95 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 4 3.5c x 50 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 5 4c x 35 sqmm aluminium conductor cable a2xfy , cable tray 1 supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 100 mm width x 50 mm depth x 1.6 mm thickness , cable tray 2 supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 300 mm width x 50 mm depth x 1.6 mm thickness , cable tray 3 supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 600 mm width x 62.5 mm depth x 2.0 mm thickness , cable tray “bends” supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.100 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 1 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.150 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 2 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.300 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends”3 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.450 mm width x 50 mm depth x 2 mm thickness , cable tray “bends” 4 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.600 mm width x 62.5 mm depth x 2.0 mm thickness , mv cable supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 300 sqmm, aluminium conductor cable a2xfy , mv cable 1 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 240 sqmm, aluminium conductor cable a2xfy , mv cable 2 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 120 sqmm, aluminium conductor cable a2xfy , mv cable 3 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 95 sqmm, aluminium conductor cable a2xfy , earthing 1 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 2 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. , earthing 3 earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. , earthing 4 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 5 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , earthing 6 providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required. , earthing 7 providing and fixing earth bus of 50 mm x 5 mm copper strip on surface for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : , fiting & fixtures 4 supplying and fixing recess mounted 12 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 6 supply, installation, testing and commissioning of 400 mm sweep, 65w, blade material aluminium blades , speed & oscillation 3 speed, pull cord for speed and oscillation.air delivery minimum 72 m³ / min, speed minimun 1350 revolution per minute.suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , fiting & fixtures 8 supplying installation testing & commissioning ofb22 based 9w led 3 star bulb with 850 lumen, 6k color temperature including holder. , fiting & fixtures 9 supplying installation testing & commissioning of black painted extruded aluminium housing. green / red led’s mounted inside the housing. laser engraved signage matter on single / double acrylic sheet fixed on one side suitable for wall / ceiling / suspension type single / double sided display. in double sided version black paper is inserted. ni cd battery back up to 2 hrs. ( charged up to 8 10 hrs ) .mounting strings provided for pendent mounting operating voltage 150 280v ac ambient operating temperature. – 0 to 450c ingress protection – ip42.including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required.   220208 besl 03 led ssd wbb green 240 3 8wor220209 besl 03 led ssd wbb red 240 3 8wor220210 besl 03 led dsd wbb green 240 3 8wor220211 besl 03 led dsd wbb red 240 3 8w , fiting & fixtures 10 supply, installation, testing & erecting of ip66 bulkhead surface type lighting fixture 10w made up of pressure die cast aluminium housing and polyster powder coated die cast aluminium with high quality polycarbonate diffuser in opal finish for glare free light distribution.high efficiency long life led module with smd led package mounted on mcpcb with lumen efficacy of >95 lm / w with system lumen 950. powered by integral electronic led driver with apfc with low thd output short / open circuit protection. cct 5700, cri>80, system efficacy>90lm / w, thd<15%, pf>.95, ip66, ik 10, life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz.including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. cat ref: havells : hexaft10wled857ssymbopc or approved equivalent. , civil & misc works1 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. , civil & misc works2 providing and fixing h.t. danger notice plate of 250 mm x 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. , civil & misc works3 supplying and making cable route marker with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm x 60 cm at the bottom and 50 cm x 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. , civil & misc works4 supplying and fixing cable route marker with 10 cm x 10 cm x 5 mm thick g.i. plate with inscription there on, bolted / welded to 35 mm x 35 mm x 6 mm angle iron, 60 cm long and fixing the same in ground as required. , civil & misc works5 providing & fixing in position 1000 mm wide , electrical insulating rubber mats as per is 15652:2006, 2 mm thick, suitable up to 1.1 kv , fire retardant, no effect of acids, alkalis and transformer oils, moisture proof, high tensile strengthandtexture finish / cloth impression ( anti slip , marking on top ) , civil & misc works6 supply & fixing shock treatment chart duly mounted on a wooden frame with 5 mm thick glass as required ( approx front area 1.20 sq metre ) , 40 kvaups supplying, installation, testing and commissioningof online double conversion fully microprocessor based , indoor type, compact ups system of following rating with igbt based pwm technology to achieve thd < 3% and input power factor of greater than 0.95 at 50% loading, suitable for three phase ac input voltage 380 v to 440 v, 50 hz +3% / 3 % and three phase ac output voltage 415 ± 1% volts & frequency 50 ± 0.5 hz , inbuilt isolation transformer, necessary vrla batteries of suitable size having 30 minutes back up time , mounting rack including and suitable size connecting cable ( for ups to battery and battery to battery ) , static and maintenance bypass switch, snmp card for rs232 / ethernet ip computability for operation and monitoring etc. with all components as mentioned , specifications, complete as required.note : concerning vendor needs to furnish the battery sizing calculations at the time of ga approval and battery size has to be as per the approved ga drawing. , external lighting 1 supply and erection of 4 metre height hot dipgalvanized octagonal street light pole with followingarm with top dia 70 mm and bottom dia a / f 130 mm, made of 3 mm thick sheet along with base plate of size220 x 220 x 12 mm , small door opening for junctionbox mounting with mcb & connector, cement concreteof 1:3:6 including excavation, refilling and suitable sizefoundation bolts with template and all complete jobasrequired. ( but without pole collar ) single arm , external lighting 2 supplying and fixing 40 / 45 watt led type street lightwith die cast aluminium housing for ingress protectionof ip65 and complete with all accessories etc, onpole / building including connection with fr pvcinsulated copper conductor cable and earthing thebody etc. as required. , ip based cctv system 1 sitc of 2 megapixel @ 25fps, h.265 ip bullet camera, 1 / 2.9 cmos with 2.8~12mm varifocal lens, 0 lux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 2 sitc of 2 megapixel @ 25fps, h.265 ip dome camera, 1 / 2.9 cmos with 3.6 fixed mm 0 lux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 3 sitc of 2 megapixel @ 25fps, ptz camera h.265 ip dome camera, 1 / 2.9 cmos with 2.6 fixed lenslux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 4 sitc of 32ch 4k ivr , h.265 / h.264 • 1080p real time • 4k display • dual lan • 8x hdd • raid •web plugin free h.265 / h.264 compression technology 4k display for clear monitoring up to 1080p 16ch decoding ability smart search ii smart vca event searchsupport raid 0, 1, 5 supported to prevent from recording data loss browsers supported: ie , smart functions : target count, electric fence, face detection, humaniod detection, retrograde detection, leave position detectio output, local & network backup etc. complete as required. , cctv 5 sitc of harddiskdrive8tb, 24 / 7surveillance category only complete etc as required.etc.all complete , cctv 6 sitc of 55 led narrow bazel for monitoring for nvr server etc. all complete. , cctv 7 sitc of rj 45 outlets near the cameras etc. all complete. etc. all complete. , cctv 8 sitc of cat 6 patch cords 1 meter high quality four pair twisted stranded cable terminated with rj45 modular plugs at both the ends. , signage 1 providing & fixing of building direction signage mounted on pole, with pole of 100x100mm shs ( square hollow section ) of height of 5600mm, and sign size of 900x1050, sign made of aluminiu c section of 60mm with internal framing to support the frame in ms tubes hollow section, frame work duly painted with anti rust coatings, with facia of 3mm thick exterior grade aluminium composite panel, cladded with uv cured digital printed retroreflective sheet of 3m make, and back panel of 3mm exterior grade acp, all pipes to be painted in approved color. cost shall includecost towards installation, including excuvation and filling up with specified pcc and fixing of foundation bolts as specified, also it shall include the designing charges.all complete as per direction by engineer in charge. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , 2 tr air conditioning 1 split ac ( inverter model ) : supply, installation, testing, commissioning of split type wall mounted air conditioning units of following capacity including inddor, outdoor unit fitted with inverter based rotary compressor fitted with rotary compressor, copper condensor and first charge refrigent r410a / eco friendly green gas only, all complete including all electrical connections to the electrical power supply system of the building, includingbut not limited to supply of all electrical plugs, etc., as necessary, lengthening of all electrical wires of ac units ( both indoor and outdoor ) , drain pipe andincluding suitable voltage stabilisers, etc. so as to place them in a concealed manner in the desired position. the copper pipes and electrical cables shall be concealed in approved manner and neatly run in straight lines in a workman like manner with proper supports. complete supply and installation of split2 tr star rating 3 star , refrigerant piping copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 25 mm od, wall thickness >= 1.2 mm ( insulation 19 mm thick ) , refrigerant piping 1 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 19.1 mm od, wall thickness >= 1.0 mm ( insulation 13 mm thick ) , refrigerant piping 2 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 15.9 mm od, wall thickness >= 0.8 mm ( insulation 13 mm thick ) , refrigerant piping 3 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 9.5 mm od, wall thickness >= 0.8 mm ( insulation 13 mm thick ) , drain piping providing and fixing of cpvc 6 kg / cm2 drainpiping complete with fittings, supports, 6 mm thick closed cell elastomeric insulation as per specifications and drawings. 20 mm , drain piping 1 providing and fixing of cpvc 6 kg / cm2 drainpiping complete with fittings, supports, 6 mm thick closed cell elastomeric insulation as per specifications and drawings. 32 mm , main oxygen manifold supply, installation, testing and commissioning of following gas manifold system ( excluding cylinders ) . the manifold is configured for designed numbers of cylinders and is suitable to withstand a pressure of 145 kg / cm2, along withhigh pressure copper annealed tail pipes with end brass adapter suitable for cylinders and manifold. top frame comprising of high pressure copper pipes of size 1 / 2” nb x 15swg with high pressure brass fittings made of high tensile brass and connections through nonreturn valves, the design of middle and bottomframes is provided to fit both round and flat bottom cylinders safely. the manifold is tested ( hydraulically ) at 3500 psig. ( it should be ce and iso 13485 certified ) mani fold oxygen manifold 6 + 6 cylinder banks complete with nrv, middle frame, bottom frame with ce marked, , emergency manifold emergency oxygen manifold 01 + 01 cylinder emergency manifold with complete regulator, nrv, middle frame & bottom frame, , control panelfor oxygen fully automatic three port control panel for oxygen supply, installation, testing and commissioning of automatic manifold control panel would provide a duty or standby gas supply from two cylinder banks with automaticchangeover the manifold indicates local status and has a remote indicator facility. automaticmanifold control panel would be designed to supply the mgps with a constant pressure supply via a control panel form two equal banks of cylinders and the changeover from the ‘duty’ to the ‘standby’ bank of cylinders would beautomatic. automatic changeover from the duty to the standby bank would occur at a cylinder pressure that will ensure the maximum usage of the contents of the duty bank. the changeover unit would be provided with monitoring todetect and display: duty bank operating, duty bank empty, standby bank operating, and standby bank below 10 % when the duty bank is empty, reserve bank low, pipeline pressure fault. there would be facility to connect liquidoxygen supply ( i.e. three port control panel ) ( it should be ce and iso 13485 certified ) fully automatic three port control panel for oxygen , emergency manifold line regulator emergency manifold line regulator supply, installation, testing and commissioning of emergency manifold line regulator i n p u t p r e s s u r e 1 5 0 k g / c m 2 working pressure 4 kg / cm2 it should be ce and iso 13485 certified.oxygen input pressure 150 kg / cm2 working pressure 4 kg / cm2capacity : 1500 lpm , cylinderconnectingpipe ( pig tail ) supply, installation, testing and commissioning of cylinder connecting pipe ( pig tail ) made up of flexible ss hose with safety cord 5 / 8 inch bsp gland nut and one side 1 / 2 inch bsp internal threads having one meter length. ( oxygen 24 , n2o 10, co2 4 ) , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , medical air ( 4 bar ) outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve, supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified.42mm , isolation valve 2 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 28mm , isolation valve 3 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 22mm , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness , pipeline 4 medical grade copper pipeline ( in mtrs. ) as per en 13348, 28 mm ( od ) x 0.9 mm thickness , pipeline 5 medical grade copper pipeline ( in mtrs. ) as per en 13348, 42 mm ( od ) x 1.2 mm thickness , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 2268 mm x ( w ) 922 mm x ( h ) 610 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , paediatric bed with mattress paediatric bed of overall sizes in mm: 1500 ( l ) x 850 ( w ) x 1210 ( h ) flat single section bed with grille frame on 4 sides.suitable for children up to 12 years.drop down grill frame on both sides for protection of the patient.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral white , bed side locker type i over all dimension :402mmlx422mm wx840mm ht .locker should have one cabinet and one drawer unit .both provided with cam lock .there should be gap between drawer and unit to keep general items for frequesnt use castors are provided for easy handling .drawer made up of crca sheet 1 mm thick and has ball slide for easy operation .top ss 304 sheet 0.8 mm thick castors 50 mmdia , hamdle abs ..powder coating of epoxy polyester , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , strecher on trolley type i 2005mm ( l ) x666mm ( w ) x827mm ( h ) .the trolley should be made of 31.75 and 25.4 mm dia 1.6 mm thick erw tube.holder for stretcher should be made up of mild steel.castor should be of 200 mm dia , diagonal locking castor.stretcher should be made up oferw tubeof dia 25.4 mm and thickness 1.6 mm.top sheet should be made of crca sheetof thickness 1.2 mm with contour shape to accommodate patient.iv pole holder should be made ofms .maximum safe work load should be 135 kg.to ensure qood quality welding co2 argonprocess should be adhered to.all metal componentsshould be pre treated with zinc phosphating in 9 tank porcess and then powder coated with anti microbialepoxy polyster powder coating.goods should be supplied in knocked down construction to reduce carbon emission. performance test :proof loading test , cycle tests , impact test, salt spray test, castor break test, the manufacturer should compilant with iso 9001, 14001, 13485, ohsas 1800 and ce certification. , doctor desk type x s / f / f executive table main desk should be of dimesion : 1350w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. side panels : ( black ) made form 18mm thick plt with pvc lipping.modesty panel : made form 18mm thick plt with pvc lipping. bigger upper panel in black and smaller lower panel in white cedar. made from 18mm thick plt with pvc lipping. mobile pedestal : one box and one filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , chair type iii s / f / f executive chair1 ) seat / back assembly: the seat and back are made up of 1.2 cm. thick hot pressed plywood, upholstered withfabric upholstery covers and moulded polyurethane foam. the back foam is designed with contoured lumbar support for extra comfort. the seat has extra thick foam on front edge to give comfort to popliteal area.high back size : 47.5 cm ( w ) x 69.5 cm ( h ) seat size : 47.0 cm. ( w ) x 48.0 cm. ( d ) 2 ) polyurethane foam: the polyurethane foam is moulded with density = 45 + / 2 kg / m 3and hardness = 20 + / 2at 25% compression. 3 ) armrests: the one piece armrests are injection moulded from black co polymer polypropylene. 4 ) center tilt synchro mechanism : the mechanism is designed with the following features:• 360 revolving type. • upright position locking. • tilt tension adjustment.• seat / back tilting ratio of 1:3 ( 60 seat tilt / 180 back tilt ) . 5 ) pneumatic height adjustment : the pneumatic height adjustment has anadjustment stroke of 12.0 cm. 6 ) telescopic bellow assembly : the bellow is 3 piece telescopic type and injection moulded in black polypropylene. 7 ) pedestal assembly , staff / visitor chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck .3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement.mx load bearing capacity should be 10 kg. , hospital curtain tracks & i.v. tree system supply installation testing & commissioning of cubical tracks system made of powder coated aluminium alloy, stain free polyster fabric , water repellent curtains , smooth movement , non sticking runnner with stainless steel hooks made from mirror finish stainless steel , adjustable height with all accessories. total quantity : 1...

Health And Family Welfare Department - Bihar

30243928 bids are invited for pile20.2.3 boring, providing and installing bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement butincluding the cost of boring, with bentonite solution andtemporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavatedearth with all lifts and leads ( length of pile for payment shall be measured upto bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc4.1.5 providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , reinforcement steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 111.41a.3.1 providing and laying vitrified tiles in floor in different sizes { thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 ( 1 cement: 4 coarse sand ) jointing with grey cement slurry @3.3 kg / sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only.laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt / antiskid finish of size size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge : flamed finish granite stone slab jet black, cherry red, elite brown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel itemgalvanised @80gsm ) 50 mm long 8mm outer diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’. the system should rest on periphery walls / partitions with the help of gi perimeter wall angle of size24x24x3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall s.s. screws. the exposed bottom portion of all t sections used in false ceiling support system shall be pre painted with polyester baked paint, for all heights. the work shall be carried out as per specifications, drawings and as per directions of the engineer in charge. with 16 mm thick beveled tegular mineral fibre antimicrobial false ceiling tile confirming to iso 5 ( class 100 ) specifications , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975.the frames shall be fixed to rcc slab or tie beam over neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to aisi 304 and 316 at 500mm c / c with minimum embedment of 100mm in rcc ( rcc to be paid separately ) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. the item also includes the submission of stability reports dulyexamined and issued by any nit / iit. the rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with dry distemper of approved brand and manufacture ( two or more coats ) and of required shade on new work , over and including priming coat of whiting to give an even shade. , ex. paint finishing walls with acrylic smooth exterior paint of required shade : new work ( two or more coat applied @ 1.67 ltr / 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm ) , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing: rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white p.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings and floors wherever required :white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm. clear depth and 250mm apron including cost of e / w. involved with 75mm cement concrete ( 1:4:8 ) over one brick designation 100 a flat soling in proper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 4.5 kg. , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 4 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 3 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 4 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 5 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 6 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 7 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 8 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 9 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 10 bell push , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , earthing 1 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 2 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 3 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 1900 mm x ( w ) 900 mm x ( h ) 600 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , desk main desk should be of dimesion : 1200w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , staff chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck . 3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement. mx load bearing capacity should be 10 kg. , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness total quantity : 1...

Department Of Health And Family Welfare - Bihar

30232919 bids are invited for pile20.2.3 boring, providing and installing bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement butincluding the cost of boring, with bentonite solution andtemporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavatedearth with all lifts and leads ( length of pile for payment shall be measured upto bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc4.1.5 providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , reinforcement steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 111.41a.3.1 providing and laying vitrified tiles in floor in different sizes { thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 ( 1 cement: 4 coarse sand ) jointing with grey cement slurry @3.3 kg / sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only.laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt / antiskid finish of size size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge : flamed finish granite stone slab jet black, cherry red, elite brown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel itemgalvanised @80gsm ) 50 mm long 8mm outer diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’. the system should rest on periphery walls / partitions with the help of gi perimeter wall angle of size24x24x3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall s.s. screws. the exposed bottom portion of all t sections used in false ceiling support system shall be pre painted with polyester baked paint, for all heights. the work shall be carried out as per specifications, drawings and as per directions of the engineer in charge. with 16 mm thick beveled tegular mineral fibre antimicrobial false ceiling tile confirming to iso 5 ( class 100 ) specifications , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975.the frames shall be fixed to rcc slab or tie beam over neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to aisi 304 and 316 at 500mm c / c with minimum embedment of 100mm in rcc ( rcc to be paid separately ) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. the item also includes the submission of stability reports dulyexamined and issued by any nit / iit. the rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with dry distemper of approved brand and manufacture ( two or more coats ) and of required shade on new work , over and including priming coat of whiting to give an even shade. , ex. paint finishing walls with acrylic smooth exterior paint of required shade : new work ( two or more coat applied @ 1.67 ltr / 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm ) , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing: rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white p.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings and floors wherever required :white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm. clear depth and 250mm apron including cost of e / w. involved with 75mm cement concrete ( 1:4:8 ) over one brick designation 100 a flat soling in proper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 4.5 kg. , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 4 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 3 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 4 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 5 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 6 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 7 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 8 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 9 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 10 bell push , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , earthing 1 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 2 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 3 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 1900 mm x ( w ) 900 mm x ( h ) 600 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , desk main desk should be of dimesion : 1200w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , staff chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck . 3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement. mx load bearing capacity should be 10 kg. , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness total quantity : 1...

Health And Family Welfare Department - Bihar

30225212 bids are invited for pile20.2.3 boring, providing and installing bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement butincluding the cost of boring, with bentonite solution andtemporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavatedearth with all lifts and leads ( length of pile for payment shall be measured upto bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc4.1.5 providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , reinforcement steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 111.41a.3.1 providing and laying vitrified tiles in floor in different sizes { thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 ( 1 cement: 4 coarse sand ) jointing with grey cement slurry @3.3 kg / sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only.laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt / antiskid finish of size size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge : flamed finish granite stone slab jet black, cherry red, elite brown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel itemgalvanised @80gsm ) 50 mm long 8mm outer diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’. the system should rest on periphery walls / partitions with the help of gi perimeter wall angle of size24x24x3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall s.s. screws. the exposed bottom portion of all t sections used in false ceiling support system shall be pre painted with polyester baked paint, for all heights. the work shall be carried out as per specifications, drawings and as per directions of the engineer in charge. with 16 mm thick beveled tegular mineral fibre antimicrobial false ceiling tile confirming to iso 5 ( class 100 ) specifications , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975.the frames shall be fixed to rcc slab or tie beam over neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to aisi 304 and 316 at 500mm c / c with minimum embedment of 100mm in rcc ( rcc to be paid separately ) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. the item also includes the submission of stability reports dulyexamined and issued by any nit / iit. the rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with dry distemper of approved brand and manufacture ( two or more coats ) and of required shade on new work , over and including priming coat of whiting to give an even shade. , ex. paint finishing walls with acrylic smooth exterior paint of required shade : new work ( two or more coat applied @ 1.67 ltr / 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm ) , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing: rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white p.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings and floors wherever required :white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm. clear depth and 250mm apron including cost of e / w. involved with 75mm cement concrete ( 1:4:8 ) over one brick designation 100 a flat soling in proper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 4.5 kg. , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 4 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 3 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 4 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 5 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 6 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 7 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 8 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 9 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 10 bell push , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , earthing 1 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 2 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 3 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 1900 mm x ( w ) 900 mm x ( h ) 600 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , desk main desk should be of dimesion : 1200w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , staff chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck . 3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement. mx load bearing capacity should be 10 kg. , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness total quantity : 1...

Bihar Medical Service And Infrastructure Corporation Ltd - Bihar

30223853 bids are invited for pile20.2.3 boring, providing and installing bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement butincluding the cost of boring, with bentonite solution andtemporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavatedearth with all lifts and leads ( length of pile for payment shall be measured upto bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc4.1.5 providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , reinforcement steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 111.41a.3.1 providing and laying vitrified tiles in floor in different sizes { thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 ( 1 cement: 4 coarse sand ) jointing with grey cement slurry @3.3 kg / sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only.laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt / antiskid finish of size size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge : flamed finish granite stone slab jet black, cherry red, elite brown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel itemgalvanised @80gsm ) 50 mm long 8mm outer diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’. the system should rest on periphery walls / partitions with the help of gi perimeter wall angle of size24x24x3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall s.s. screws. the exposed bottom portion of all t sections used in false ceiling support system shall be pre painted with polyester baked paint, for all heights. the work shall be carried out as per specifications, drawings and as per directions of the engineer in charge. with 16 mm thick beveled tegular mineral fibre antimicrobial false ceiling tile confirming to iso 5 ( class 100 ) specifications , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975.the frames shall be fixed to rcc slab or tie beam over neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to aisi 304 and 316 at 500mm c / c with minimum embedment of 100mm in rcc ( rcc to be paid separately ) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. the item also includes the submission of stability reports dulyexamined and issued by any nit / iit. the rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with dry distemper of approved brand and manufacture ( two or more coats ) and of required shade on new work , over and including priming coat of whiting to give an even shade. , ex. paint finishing walls with acrylic smooth exterior paint of required shade : new work ( two or more coat applied @ 1.67 ltr / 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm ) , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing: rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white p.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings and floors wherever required :white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm. clear depth and 250mm apron including cost of e / w. involved with 75mm cement concrete ( 1:4:8 ) over one brick designation 100 a flat soling in proper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 4.5 kg. , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 4 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 3 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 4 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 5 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 6 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 7 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 8 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 9 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 10 bell push , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , earthing 1 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 2 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 3 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 1900 mm x ( w ) 900 mm x ( h ) 600 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , desk main desk should be of dimesion : 1200w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , staff chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck . 3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement. mx load bearing capacity should be 10 kg. , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness total quantity : 1...

Health And Family Welfare Department - Bihar

30223082 bids are invited for pile20.2.3 boring, providing and installing bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement butincluding the cost of boring, with bentonite solution andtemporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavatedearth with all lifts and leads ( length of pile for payment shall be measured upto bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc4.1.5 providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , reinforcement steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 111.41a.3.1 providing and laying vitrified tiles in floor in different sizes { thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 ( 1 cement: 4 coarse sand ) jointing with grey cement slurry @3.3 kg / sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only.laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt / antiskid finish of size size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge : flamed finish granite stone slab jet black, cherry red, elite brown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel itemgalvanised @80gsm ) 50 mm long 8mm outer diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’. the system should rest on periphery walls / partitions with the help of gi perimeter wall angle of size24x24x3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall s.s. screws. the exposed bottom portion of all t sections used in false ceiling support system shall be pre painted with polyester baked paint, for all heights. the work shall be carried out as per specifications, drawings and as per directions of the engineer in charge. with 16 mm thick beveled tegular mineral fibre antimicrobial false ceiling tile confirming to iso 5 ( class 100 ) specifications , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975.the frames shall be fixed to rcc slab or tie beam over neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to aisi 304 and 316 at 500mm c / c with minimum embedment of 100mm in rcc ( rcc to be paid separately ) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. the item also includes the submission of stability reports dulyexamined and issued by any nit / iit. the rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with dry distemper of approved brand and manufacture ( two or more coats ) and of required shade on new work , over and including priming coat of whiting to give an even shade. , ex. paint finishing walls with acrylic smooth exterior paint of required shade : new work ( two or more coat applied @ 1.67 ltr / 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm ) , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing: rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white p.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings and floors wherever required :white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm. clear depth and 250mm apron including cost of e / w. involved with 75mm cement concrete ( 1:4:8 ) over one brick designation 100 a flat soling in proper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 4.5 kg. , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 4 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 3 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 4 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 5 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 6 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 7 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 8 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 9 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 10 bell push , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , earthing 1 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 2 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 3 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 1900 mm x ( w ) 900 mm x ( h ) 600 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , desk main desk should be of dimesion : 1200w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , staff chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck . 3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement. mx load bearing capacity should be 10 kg. , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness total quantity : 1...

Health And Family Welfare Department - Bihar

30222705 bids are invited for pile20.2.3 boring, providing and installing bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement butincluding the cost of boring, with bentonite solution andtemporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavatedearth with all lifts and leads ( length of pile for payment shall be measured upto bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc4.1.5 providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , reinforcement steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 111.41a.3.1 providing and laying vitrified tiles in floor in different sizes { thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 ( 1 cement: 4 coarse sand ) jointing with grey cement slurry @3.3 kg / sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only.laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt / antiskid finish of size size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge : flamed finish granite stone slab jet black, cherry red, elite brown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel itemgalvanised @80gsm ) 50 mm long 8mm outer diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’. the system should rest on periphery walls / partitions with the help of gi perimeter wall angle of size24x24x3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall s.s. screws. the exposed bottom portion of all t sections used in false ceiling support system shall be pre painted with polyester baked paint, for all heights. the work shall be carried out as per specifications, drawings and as per directions of the engineer in charge. with 16 mm thick beveled tegular mineral fibre antimicrobial false ceiling tile confirming to iso 5 ( class 100 ) specifications , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975.the frames shall be fixed to rcc slab or tie beam over neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to aisi 304 and 316 at 500mm c / c with minimum embedment of 100mm in rcc ( rcc to be paid separately ) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. the item also includes the submission of stability reports dulyexamined and issued by any nit / iit. the rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with dry distemper of approved brand and manufacture ( two or more coats ) and of required shade on new work , over and including priming coat of whiting to give an even shade. , ex. paint finishing walls with acrylic smooth exterior paint of required shade : new work ( two or more coat applied @ 1.67 ltr / 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm ) , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing: rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white p.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings and floors wherever required :white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm. clear depth and 250mm apron including cost of e / w. involved with 75mm cement concrete ( 1:4:8 ) over one brick designation 100 a flat soling in proper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 4.5 kg. , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 4 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 3 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 4 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 5 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 6 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 7 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 8 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 9 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 10 bell push , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , earthing 1 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 2 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 3 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 1900 mm x ( w ) 900 mm x ( h ) 600 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , desk main desk should be of dimesion : 1200w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , staff chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck . 3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement. mx load bearing capacity should be 10 kg. , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness total quantity : 1...

Health And Family Welfare Department - Bihar

30221807 bids are invited for pile20.2.3 boring, providing and installing bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement butincluding the cost of boring, with bentonite solution andtemporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavatedearth with all lifts and leads ( length of pile for payment shall be measured upto bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc4.1.5 providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , reinforcement steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 111.41a.3.1 providing and laying vitrified tiles in floor in different sizes { thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 ( 1 cement: 4 coarse sand ) jointing with grey cement slurry @3.3 kg / sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only.laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt / antiskid finish of size size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge : flamed finish granite stone slab jet black, cherry red, elite brown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel itemgalvanised @80gsm ) 50 mm long 8mm outer diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’. the system should rest on periphery walls / partitions with the help of gi perimeter wall angle of size24x24x3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall s.s. screws. the exposed bottom portion of all t sections used in false ceiling support system shall be pre painted with polyester baked paint, for all heights. the work shall be carried out as per specifications, drawings and as per directions of the engineer in charge. with 16 mm thick beveled tegular mineral fibre antimicrobial false ceiling tile confirming to iso 5 ( class 100 ) specifications , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975.the frames shall be fixed to rcc slab or tie beam over neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to aisi 304 and 316 at 500mm c / c with minimum embedment of 100mm in rcc ( rcc to be paid separately ) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. the item also includes the submission of stability reports dulyexamined and issued by any nit / iit. the rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with dry distemper of approved brand and manufacture ( two or more coats ) and of required shade on new work , over and including priming coat of whiting to give an even shade. , ex. paint finishing walls with acrylic smooth exterior paint of required shade : new work ( two or more coat applied @ 1.67 ltr / 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm ) , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing: rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white p.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings and floors wherever required :white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm. clear depth and 250mm apron including cost of e / w. involved with 75mm cement concrete ( 1:4:8 ) over one brick designation 100 a flat soling in proper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 4.5 kg. , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 4 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 3 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 4 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 5 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 6 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 7 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 8 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 9 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 10 bell push , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , earthing 1 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 2 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 3 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 1900 mm x ( w ) 900 mm x ( h ) 600 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , desk main desk should be of dimesion : 1200w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , staff chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck . 3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement. mx load bearing capacity should be 10 kg. , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness total quantity : 1...

Health And Family Welfare Department - Bihar

30221801 bids are invited for pile20.2.3 boring, providing and installing bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement butincluding the cost of boring, with bentonite solution andtemporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavatedearth with all lifts and leads ( length of pile for payment shall be measured upto bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc4.1.5 providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , reinforcement steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 111.41a.3.1 providing and laying vitrified tiles in floor in different sizes { thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 ( 1 cement: 4 coarse sand ) jointing with grey cement slurry @3.3 kg / sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only.laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt / antiskid finish of size size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge : flamed finish granite stone slab jet black, cherry red, elite brown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel itemgalvanised @80gsm ) 50 mm long 8mm outer diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’. the system should rest on periphery walls / partitions with the help of gi perimeter wall angle of size24x24x3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall s.s. screws. the exposed bottom portion of all t sections used in false ceiling support system shall be pre painted with polyester baked paint, for all heights. the work shall be carried out as per specifications, drawings and as per directions of the engineer in charge. with 16 mm thick beveled tegular mineral fibre antimicrobial false ceiling tile confirming to iso 5 ( class 100 ) specifications , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975.the frames shall be fixed to rcc slab or tie beam over neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to aisi 304 and 316 at 500mm c / c with minimum embedment of 100mm in rcc ( rcc to be paid separately ) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. the item also includes the submission of stability reports dulyexamined and issued by any nit / iit. the rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with dry distemper of approved brand and manufacture ( two or more coats ) and of required shade on new work , over and including priming coat of whiting to give an even shade. , ex. paint finishing walls with acrylic smooth exterior paint of required shade : new work ( two or more coat applied @ 1.67 ltr / 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm ) , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing: rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white p.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings and floors wherever required :white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm. clear depth and 250mm apron including cost of e / w. involved with 75mm cement concrete ( 1:4:8 ) over one brick designation 100 a flat soling in proper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 4.5 kg. , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 4 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 3 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 4 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 5 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 6 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 7 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 8 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 9 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 10 bell push , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , earthing 1 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 2 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 3 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 1900 mm x ( w ) 900 mm x ( h ) 600 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , desk main desk should be of dimesion : 1200w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , staff chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck . 3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement. mx load bearing capacity should be 10 kg. , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness total quantity : 1...

Health And Family Welfare Department - Bihar

30221787 bids are invited for pile20.2.3 boring, providing and installing bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement butincluding the cost of boring, with bentonite solution andtemporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavatedearth with all lifts and leads ( length of pile for payment shall be measured upto bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc4.1.5 providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , reinforcement steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 111.41a.3.1 providing and laying vitrified tiles in floor in different sizes { thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 ( 1 cement: 4 coarse sand ) jointing with grey cement slurry @3.3 kg / sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only.laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt / antiskid finish of size size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge : flamed finish granite stone slab jet black, cherry red, elite brown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel itemgalvanised @80gsm ) 50 mm long 8mm outer diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’. the system should rest on periphery walls / partitions with the help of gi perimeter wall angle of size24x24x3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall s.s. screws. the exposed bottom portion of all t sections used in false ceiling support system shall be pre painted with polyester baked paint, for all heights. the work shall be carried out as per specifications, drawings and as per directions of the engineer in charge. with 16 mm thick beveled tegular mineral fibre antimicrobial false ceiling tile confirming to iso 5 ( class 100 ) specifications , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975.the frames shall be fixed to rcc slab or tie beam over neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to aisi 304 and 316 at 500mm c / c with minimum embedment of 100mm in rcc ( rcc to be paid separately ) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. the item also includes the submission of stability reports dulyexamined and issued by any nit / iit. the rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with dry distemper of approved brand and manufacture ( two or more coats ) and of required shade on new work , over and including priming coat of whiting to give an even shade. , ex. paint finishing walls with acrylic smooth exterior paint of required shade : new work ( two or more coat applied @ 1.67 ltr / 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm ) , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing: rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white p.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings and floors wherever required :white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm. clear depth and 250mm apron including cost of e / w. involved with 75mm cement concrete ( 1:4:8 ) over one brick designation 100 a flat soling in proper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 4.5 kg. , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 4 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 3 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 4 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 5 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 6 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 7 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 8 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 9 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 10 bell push , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , earthing 1 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 2 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 3 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 1900 mm x ( w ) 900 mm x ( h ) 600 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , desk main desk should be of dimesion : 1200w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , staff chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck . 3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement. mx load bearing capacity should be 10 kg. , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness total quantity : 1...

Health And Family Welfare Department - Bihar

30221454 bids are invited for pile20.2.3 boring, providing and installing bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement butincluding the cost of boring, with bentonite solution andtemporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavatedearth with all lifts and leads ( length of pile for payment shall be measured upto bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc4.1.5 providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , reinforcement steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 111.41a.3.1 providing and laying vitrified tiles in floor in different sizes { thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 ( 1 cement: 4 coarse sand ) jointing with grey cement slurry @3.3 kg / sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only.laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt / antiskid finish of size size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge : flamed finish granite stone slab jet black, cherry red, elite brown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel itemgalvanised @80gsm ) 50 mm long 8mm outer diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’. the system should rest on periphery walls / partitions with the help of gi perimeter wall angle of size24x24x3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall s.s. screws. the exposed bottom portion of all t sections used in false ceiling support system shall be pre painted with polyester baked paint, for all heights. the work shall be carried out as per specifications, drawings and as per directions of the engineer in charge. with 16 mm thick beveled tegular mineral fibre antimicrobial false ceiling tile confirming to iso 5 ( class 100 ) specifications , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975.the frames shall be fixed to rcc slab or tie beam over neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to aisi 304 and 316 at 500mm c / c with minimum embedment of 100mm in rcc ( rcc to be paid separately ) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. the item also includes the submission of stability reports dulyexamined and issued by any nit / iit. the rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with dry distemper of approved brand and manufacture ( two or more coats ) and of required shade on new work , over and including priming coat of whiting to give an even shade. , ex. paint finishing walls with acrylic smooth exterior paint of required shade : new work ( two or more coat applied @ 1.67 ltr / 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm ) , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing: rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white p.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings and floors wherever required :white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm. clear depth and 250mm apron including cost of e / w. involved with 75mm cement concrete ( 1:4:8 ) over one brick designation 100 a flat soling in proper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 4.5 kg. , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 4 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 3 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 4 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 5 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 6 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 7 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 8 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 9 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 10 bell push , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , earthing 1 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 2 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 3 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 1900 mm x ( w ) 900 mm x ( h ) 600 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , desk main desk should be of dimesion : 1200w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , staff chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck . 3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement. mx load bearing capacity should be 10 kg. , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness total quantity : 1...

Health And Family Welfare Department - Bihar

30220852 bids are invited for pile20.2.3 boring, providing and installing bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement butincluding the cost of boring, with bentonite solution andtemporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavatedearth with all lifts and leads ( length of pile for payment shall be measured upto bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc4.1.5 providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , reinforcement steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 111.41a.3.1 providing and laying vitrified tiles in floor in different sizes { thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 ( 1 cement: 4 coarse sand ) jointing with grey cement slurry @3.3 kg / sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only.laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt / antiskid finish of size size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge : flamed finish granite stone slab jet black, cherry red, elite brown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel itemgalvanised @80gsm ) 50 mm long 8mm outer diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’. the system should rest on periphery walls / partitions with the help of gi perimeter wall angle of size24x24x3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall s.s. screws. the exposed bottom portion of all t sections used in false ceiling support system shall be pre painted with polyester baked paint, for all heights. the work shall be carried out as per specifications, drawings and as per directions of the engineer in charge. with 16 mm thick beveled tegular mineral fibre antimicrobial false ceiling tile confirming to iso 5 ( class 100 ) specifications , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975.the frames shall be fixed to rcc slab or tie beam over neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to aisi 304 and 316 at 500mm c / c with minimum embedment of 100mm in rcc ( rcc to be paid separately ) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. the item also includes the submission of stability reports dulyexamined and issued by any nit / iit. the rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with dry distemper of approved brand and manufacture ( two or more coats ) and of required shade on new work , over and including priming coat of whiting to give an even shade. , ex. paint finishing walls with acrylic smooth exterior paint of required shade : new work ( two or more coat applied @ 1.67 ltr / 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm ) , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing: rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white p.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings and floors wherever required :white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm. clear depth and 250mm apron including cost of e / w. involved with 75mm cement concrete ( 1:4:8 ) over one brick designation 100 a flat soling in proper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 4.5 kg. , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 4 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 3 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 4 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 5 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 6 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 7 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 8 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 9 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 10 bell push , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , earthing 1 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 2 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 3 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 1900 mm x ( w ) 900 mm x ( h ) 600 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , desk main desk should be of dimesion : 1200w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , staff chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck . 3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement. mx load bearing capacity should be 10 kg. , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness total quantity : 1...

Health And Family Welfare Department - Bihar

30220634 bids are invited for pile20.2.3 boring, providing and installing bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement butincluding the cost of boring, with bentonite solution andtemporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavatedearth with all lifts and leads ( length of pile for payment shall be measured upto bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc4.1.5 providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , reinforcement steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 111.41a.3.1 providing and laying vitrified tiles in floor in different sizes { thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 ( 1 cement: 4 coarse sand ) jointing with grey cement slurry @3.3 kg / sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only.laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt / antiskid finish of size size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge : flamed finish granite stone slab jet black, cherry red, elite brown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel itemgalvanised @80gsm ) 50 mm long 8mm outer diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’. the system should rest on periphery walls / partitions with the help of gi perimeter wall angle of size24x24x3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall s.s. screws. the exposed bottom portion of all t sections used in false ceiling support system shall be pre painted with polyester baked paint, for all heights. the work shall be carried out as per specifications, drawings and as per directions of the engineer in charge. with 16 mm thick beveled tegular mineral fibre antimicrobial false ceiling tile confirming to iso 5 ( class 100 ) specifications , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975.the frames shall be fixed to rcc slab or tie beam over neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to aisi 304 and 316 at 500mm c / c with minimum embedment of 100mm in rcc ( rcc to be paid separately ) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. the item also includes the submission of stability reports dulyexamined and issued by any nit / iit. the rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with dry distemper of approved brand and manufacture ( two or more coats ) and of required shade on new work , over and including priming coat of whiting to give an even shade. , ex. paint finishing walls with acrylic smooth exterior paint of required shade : new work ( two or more coat applied @ 1.67 ltr / 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm ) , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing: rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white p.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings and floors wherever required :white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm. clear depth and 250mm apron including cost of e / w. involved with 75mm cement concrete ( 1:4:8 ) over one brick designation 100 a flat soling in proper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 4.5 kg. , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 4 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 3 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 4 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 5 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 6 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 7 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 8 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 9 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 10 bell push , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , earthing 1 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 2 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 3 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 1900 mm x ( w ) 900 mm x ( h ) 600 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , desk main desk should be of dimesion : 1200w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , staff chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck . 3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement. mx load bearing capacity should be 10 kg. , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness total quantity : 1...

Health And Family Welfare Department - Bihar

30220560 bids are invited for pile20.2.3 boring, providing and installing bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement butincluding the cost of boring, with bentonite solution andtemporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavatedearth with all lifts and leads ( length of pile for payment shall be measured upto bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc4.1.5 providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , reinforcement steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 111.41a.3.1 providing and laying vitrified tiles in floor in different sizes { thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 ( 1 cement: 4 coarse sand ) jointing with grey cement slurry @3.3 kg / sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only.laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt / antiskid finish of size size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge : flamed finish granite stone slab jet black, cherry red, elite brown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel itemgalvanised @80gsm ) 50 mm long 8mm outer diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’. the system should rest on periphery walls / partitions with the help of gi perimeter wall angle of size24x24x3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall s.s. screws. the exposed bottom portion of all t sections used in false ceiling support system shall be pre painted with polyester baked paint, for all heights. the work shall be carried out as per specifications, drawings and as per directions of the engineer in charge. with 16 mm thick beveled tegular mineral fibre antimicrobial false ceiling tile confirming to iso 5 ( class 100 ) specifications , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975.the frames shall be fixed to rcc slab or tie beam over neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to aisi 304 and 316 at 500mm c / c with minimum embedment of 100mm in rcc ( rcc to be paid separately ) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. the item also includes the submission of stability reports dulyexamined and issued by any nit / iit. the rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with dry distemper of approved brand and manufacture ( two or more coats ) and of required shade on new work , over and including priming coat of whiting to give an even shade. , ex. paint finishing walls with acrylic smooth exterior paint of required shade : new work ( two or more coat applied @ 1.67 ltr / 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm ) , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing: rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white p.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings and floors wherever required :white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm. clear depth and 250mm apron including cost of e / w. involved with 75mm cement concrete ( 1:4:8 ) over one brick designation 100 a flat soling in proper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 4.5 kg. , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 4 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 3 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 4 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 5 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 6 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 7 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 8 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 9 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 10 bell push , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , earthing 1 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 2 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 3 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 1900 mm x ( w ) 900 mm x ( h ) 600 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , desk main desk should be of dimesion : 1200w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , staff chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck . 3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement. mx load bearing capacity should be 10 kg. , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness total quantity : 1...

Health And Family Welfare Department - Bihar

30220478 bids are invited for pile20.2.3 boring, providing and installing bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement butincluding the cost of boring, with bentonite solution andtemporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavatedearth with all lifts and leads ( length of pile for payment shall be measured upto bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc4.1.5 providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , reinforcement steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 111.41a.3.1 providing and laying vitrified tiles in floor in different sizes { thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 ( 1 cement: 4 coarse sand ) jointing with grey cement slurry @3.3 kg / sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only.laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt / antiskid finish of size size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge : flamed finish granite stone slab jet black, cherry red, elite brown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel itemgalvanised @80gsm ) 50 mm long 8mm outer diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’. the system should rest on periphery walls / partitions with the help of gi perimeter wall angle of size24x24x3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall s.s. screws. the exposed bottom portion of all t sections used in false ceiling support system shall be pre painted with polyester baked paint, for all heights. the work shall be carried out as per specifications, drawings and as per directions of the engineer in charge. with 16 mm thick beveled tegular mineral fibre antimicrobial false ceiling tile confirming to iso 5 ( class 100 ) specifications , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975.the frames shall be fixed to rcc slab or tie beam over neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to aisi 304 and 316 at 500mm c / c with minimum embedment of 100mm in rcc ( rcc to be paid separately ) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. the item also includes the submission of stability reports dulyexamined and issued by any nit / iit. the rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with dry distemper of approved brand and manufacture ( two or more coats ) and of required shade on new work , over and including priming coat of whiting to give an even shade. , ex. paint finishing walls with acrylic smooth exterior paint of required shade : new work ( two or more coat applied @ 1.67 ltr / 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm ) , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing: rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white p.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings and floors wherever required :white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm. clear depth and 250mm apron including cost of e / w. involved with 75mm cement concrete ( 1:4:8 ) over one brick designation 100 a flat soling in proper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 4.5 kg. , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 4 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 3 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 4 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 5 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 6 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 7 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 8 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 9 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 10 bell push , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , earthing 1 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 2 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 3 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 1900 mm x ( w ) 900 mm x ( h ) 600 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , desk main desk should be of dimesion : 1200w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , staff chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck . 3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement. mx load bearing capacity should be 10 kg. , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness total quantity : 1...

Health And Family Welfare Department - Bihar

30220348 bids are invited for pile20.2.3 boring, providing and installing bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement butincluding the cost of boring, with bentonite solution andtemporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavatedearth with all lifts and leads ( length of pile for payment shall be measured upto bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc4.1.5 providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , reinforcement steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 111.41a.3.1 providing and laying vitrified tiles in floor in different sizes { thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 ( 1 cement: 4 coarse sand ) jointing with grey cement slurry @3.3 kg / sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only.laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt / antiskid finish of size size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge : flamed finish granite stone slab jet black, cherry red, elite brown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel itemgalvanised @80gsm ) 50 mm long 8mm outer diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’. the system should rest on periphery walls / partitions with the help of gi perimeter wall angle of size24x24x3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall s.s. screws. the exposed bottom portion of all t sections used in false ceiling support system shall be pre painted with polyester baked paint, for all heights. the work shall be carried out as per specifications, drawings and as per directions of the engineer in charge. with 16 mm thick beveled tegular mineral fibre antimicrobial false ceiling tile confirming to iso 5 ( class 100 ) specifications , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975.the frames shall be fixed to rcc slab or tie beam over neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to aisi 304 and 316 at 500mm c / c with minimum embedment of 100mm in rcc ( rcc to be paid separately ) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. the item also includes the submission of stability reports dulyexamined and issued by any nit / iit. the rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with dry distemper of approved brand and manufacture ( two or more coats ) and of required shade on new work , over and including priming coat of whiting to give an even shade. , ex. paint finishing walls with acrylic smooth exterior paint of required shade : new work ( two or more coat applied @ 1.67 ltr / 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm ) , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing: rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white p.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings and floors wherever required :white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm. clear depth and 250mm apron including cost of e / w. involved with 75mm cement concrete ( 1:4:8 ) over one brick designation 100 a flat soling in proper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 4.5 kg. , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 4 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 3 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 4 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 5 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 6 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 7 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 8 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 9 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 10 bell push , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , earthing 1 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 2 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 3 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 1900 mm x ( w ) 900 mm x ( h ) 600 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , desk main desk should be of dimesion : 1200w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , staff chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck . 3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement. mx load bearing capacity should be 10 kg. , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness total quantity : 1...