Indian Oil Corporation Limited - Bihar

36125186 arc for attending fire water line leak rectification repair replacement of various under ground and above ground in fire water network at barauni refinery arc for attending fire water line leak rectification/repair/replacement of various under ground and above ground in fire water network at barauni refinery part a all units of barauni refinery and part b offsite of barauni refinery....

Oil India Limited - Bihar

34827964 provide services for replacement of 12 inch fire water line including dismantling of existing pipes, fire hydrants, monitors, earth excavation, road cutting and laying of new pipes & fittings, earth filling, road repairing etc at ps 10 barauni...

Indian Oil Corporation Limited - Bihar

28295436 maintenance and servicing of fire fighting equipments and systems in bkpl , group a bkpl barauni pump station , checking , inspection , servicing and maintenance of fire fighting system , equipments hydrants , extinguishers of all type ( dcp/co2/clean agent ) , water monitor up to the mark as per oisd/isi standards to provide & best functioning of the equipments always in best healthy condition inclusive of periodically cleaning , checking /inspection/oiling/ greasing of assemblies such as coupling , nozzles , valves , hydrants , extinguishers , hose pipes , water monitor , compounds drums , nozzles foam bunch , hose boxes , sand buckets etc , updating the data & identification tags , recording the status of checking in history register etc . as directed by the engineers in charge with all labors , carriages , materials etc . complete inclusive of all taxes . ( inspection and servicing of the equipment/fire fighting facilities is to be done periodically as mentioned against each ) : , fire hydrants ( double headed ) on monthly basis , fire extinguishers of all types & capacities on monthly basis , hose boxes monthly basis , valves of fire line of all sizes including contractor supplied grease of suitable quality on monthly basis . , foam /water monitors on monthly basis/mefg , sand buckets with stands with all bucket on monthly basis , taking delivery and refilling the extinguishers of various sizes /capabilities including supply of dry chemical powder , co2 gas etc updating the data & identification tags , recording the status of checking in history register etc as per isi standard and replacing the same as directed by engineer in charge . ( the co2 cylinder may to be taken out and delivered back within 10 days after re filling /repairing . however fire extinguishers co2 are to be supplied /kept temporary in place of each fire extinguisher for which taking out for re filling /repairing is required ) . , dry chemical powder , 0 . 2 kg dcp cartridge , 2 kg co2 cylinder , 6 . 8 kg co2 cylinder , 2kg clean agent cylinder , supply and replacing the spares /assembles etc of the fire fighting equipments system for all sizes / capacities as per isi standard and approved make with all labours , materials , carriages , inclusive of all taxes etc . complete , supply and installation of clear pvc , spiral wound hose ( pick up tube ) of length 3 m length and dia 40 mm with ss jublee clamp for tightningsuitable for existing connectors of 750 gpm monitor , hydrants sheet washer/rubber including fitting at site . , hydrants coupling washer , rubber washer for extinguisher , co2 safety valves 155kgf/cm2 , co2 safety pins , isi marked discharge pipe with horn for 2kg , 3 . 2kg , 4 . 5kg co2extinguishers , isi marked discharge pipe with horn for 6 . 5 kg and 6 . 8kg co2 exitinguishers . , rubber gasket of dcp main cap , hose plunger set & nut . , hose spring & nut , dcp main cap ( gun metal ) cp , dcp plunger pin with spring , dcp plunger top , squeezing grip ( plastic ) nozzle , replacement of fire hose box glass ( front ) , dcp cylinder discharge pipe of sufficient length for 10 kg capacity fire extinguisher , dcp cylinder discharge pipe of sufficient length for 75 kg capacity fire extinguisher , supply and fitting of plastic blank cap ( as per is 5290 , red colourwith gi chain ) suitable for 63 mm hydrant outlet as per direction of eic , supply and painting with two coats synthetic enamel paint ( asian/burger ) fire paint including scrapping , cleaning , applying one coat of red oxide primer cost of all labours , materials , carriage , taxes , letter/number writing , identification marks etc . complete in all respect . , brush painting of fire hose boxes ( inside and out side ) including stand with two coat of paint including letter/number writing ( colour to be specified by eic ) , spray/brush painting of fire bucket stand with its buckets ( 4 6 bucket set ) including letter/number writing . , spray painiting of fire extinguishers of all sizes including letter/number writing . , spray/ brush painting of foam/water monitors/double hydrant valves along with its stand post including letter/number writing . , fire siren including letter / number writing . , others , ppe maintenance / up keeping / cleaning on monthly basis of various items like helmets , breathing apparatus , water jel blanket , asbestos blanket , hand gloves ( rubber / asbestos ) , first aid box , stretcher , resuscicator , safety belt , ear muffs , fire proximity suits , safety torch , safety goggles including the cost of labour , material etc . complete as per instruction of engineer in charge . , cleaning & stacking properly the foam containers , updating stock , date of expiry , date of manufacturing on board and in register , placing foam containers at the foam monitors and water hydrants . , taking hose pipe for hydrotesting and keeping it back in positionafter drying /rolling inclusive of all taxes . , air filling in cylinders of breathing apparatus inclusive of all cost with transportation . , hydraulic testing of co2 cylinders inclusive of all taxes ( 2 to 4 . 5 kg/cm2 ) , hydraulic testing of co2 cylinders inclusive of all taxes ( 6 . 8 kg/cm2 ) , hydraulic testing of dcp cylinders of all sizes inclusive of all taxes , hydraulic testing of breathing appratus set , supply & pasting of slips on the extinguishers showing how to use the extinguishers & date wise maintenance records of fire extingusher . the good quality of adehsive to be used on slips for sticking on the extinguishers inclusive of all taxes as per direction of engineer in charge . , supply and fixing of wind socks on the position including all labour , tolls and tackels as per direction of engineer in charge inclusive of all . , patch work welding on the firefighting/foam line in case of leakage including all manpower & materials with tools and tackels with materials required as per satisfaction of the engieer in charge upto 12x12 size inclusive of all . , first aid box with snake serum , fire bucket , safety helmet , lettering with black japan paint of approved brand and manufacture . ( note: unit ea shall mean per letter per cm height ) . , supply & fitting of transparent acrylic sheet thickness 3 mm of hose box inclusive of rubber beeding by fixing it with proper adhesive wherever required complete in all respect inclusive of material , labours , consumables etc . ( inclusive of rates for both glasses and rubber beading . , complete overhauling of hand operated siren including oiling , greasing , painting and testing as per direction of eic inclusive of all tools & tackles , transportation , man power etc , testing of afff as per bis:4989 from reputed institutes like girda or any other approved laboratory in all respect by providing cas , transportation , man power etc . , maintenance and calibration of multigas detector sensor ( lel , o2 , co , h2s ) the charges includes cost ofcalibrating canisters inspection , maintenence of the detectors and issuance of the calibration certificates the cost of sending lel meterto the party workshop ( in india ) will be in the scope of iocl but after calibraiton and completion of work thecost of transportation of lel meter to iocl installation shall be in thescope of vendor . rate are for calibration of all sensor , make: m/s respo products model: qrae ii , , make: bw ( honeywell ) model: gasalertmax x , fire water line , dismantling of gate valves of sizes up to 8 of fire hydrant line e etc from bonnet cleaning and lapping the gate and refixing it with new gasket ( iocl supplied ) alongwith all tools , tackles , material , manpower etc , removal and installation of of faulty gate valves/nrv/glove valve/strainer upto 8 inch size including transportation either from owners storage point to workshop or work sit...

Oil India Limited - Bihar

23698308 hiring the repairing of 12 inch fire water line for a period of 2 (two) months under operation section, oil india limited, ps 10, begusarai, barauni on limited tender basis...

Bharat Petroleum Corporation Limited - Bihar

10550668 extension of fire water line in tank lorry parking area of bpcl muzffarpur depot in western portion of parking . scope of job includes supply & errection of all materials as per details in crfq....