42835557
construction of phase b works at jnv gaya ii ( bihar ) 1 earth work 2 earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 3 all kinds of soil 4 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 5 supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 6 excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 7 concrete work 8 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 9 1:5:10 (1 cement : 5 coarse sand (zone iii) : 10 graded stone aggregate 40 mm nominal size) 10 providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : 11 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). 12 providing and laying damp proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone iii): 4 graded stone aggregate 12.5mm nominal size) 13 providing & applying a coat of residual petroleum bitumen of grade of vg 10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 14 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 15 reinforcedcementconcrete 16 centering and shuttering including strutting, propping etc. and removal of form for all heights: 17 foundations, footings, bases of columns, etc. for mass concrete 18 columns, pillars, piers, abutments, posts and struts 19 small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like 20 edges of slabs and breaks in floors and walls 21 under 20 cms wide 22 suspended floors, roofs, landings, balconies and access platform. 23 lintels, beams, plinth beams, girders, bressumers and cantilevers. 24 providing precast cement concrete jali 1:2:4 (1 cement : 2 coarse sand(zone iii) : 4 graded stone aggregate 6mm nominal size), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing with cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits. 25 50 mm thick 26 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 27 thermo mechanically treated bars of grade fe 500d or more. 28 add for plaster drip course/ groove in plastered surface or moulding to r.c.c. projections. 29 providing and laying in position machine batched and machine mixed design mix m 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per is: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of engineer in charge.“(note : cement content considered in this item is @ 330 kg/cum.“excess/ less cement used as per design mix is payable/recoverable separately). 30 all works upto plinth level 31 all works above plinth level upto floor v level 32 add for using extra cement in the items of design mix over and above the specified cement content therein. 33 brick work 34 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in foundation and plinth in: 35 cement mortar 1:6 (1 cement : 6 coarse sand) 36 providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick aac blocks in super structure above plinth level up to floor v level with rcc band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of engineer in charge. (the payment of rcc band and reinforcement shall be made for seperately).: 37 half brick masonry with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level. 38 cement mortar 1:4 (1 cement :4 coarse sand) 39 extra for providing and placing in position 2 nos 6mm dia. m.s. bars at every third course of half brick masonry. 40 brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand). 41 marble work 42 providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 43 raj nagar plain white marble/ udaipur green marble/ zebra black marble 44 area of slab over 0.50 sqm 45 granite of any colour and shade 46 area of slab over 0.50 sqm 47 providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer in charge. 48 marble work 49 granite work 50 extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 51 wood work & pvc work 52 float glass panes 53 4mm thick glass pane (weight not less than 10 kg/sqm 54 extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. (area of opening for glass panes excluding portion inside rebate shall be measured). 55 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 56 35 mm thick including isi marked stainless steel butt hinges with necessary screws 57 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 58 extra for cutting rebate in flush door shutters (total area of the shutter to be measured). 59 providing and fixing wire gauge shutters using galvanized m.s. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 60 35 mm thick shutters 61 kiln seasoned and chemically treated hollock wood 62 providing and fixing fly proof galvanized m.s. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. 63 with 12 mm mild steel u beading 64 providing and fixing isi marked oxidised m.s. single acting spring hinges with necessary screws etc. complete : 65 150 mm 66 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete. 67 250 mm weighing not less than 150 gms 68 providing and fixing aluminium sliding door bolts, isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 69 250x16 mm 70 providing and fixing aluminium tower bolts, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 71 200x10 mm 72 providing and fixing aluminium hanging floor door stopper, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. 73 twin rubber stopper 74 providing and fixing factory made upvc white colour sliding glazed window upto 1.50 m in height dimension comprising of upvc multi chambered frame with in built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to upvc profile), appropriate dimension of upvc extruded glazing beads and upvc extruded interlocks, epdm gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), g.i fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of engineer in charge. (single / double glass panes, wire mesh and silicon sealent shall be paid separately). variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 75 three track three panels sliding window with fly proof s.s wire mesh (two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (area of window above 1.75 sqm). 76 steel work 77 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 78 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 79 providing and fixing t iron frames for doors, windows and ventilators of mild steel tee sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 80 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 81 providing and fixing circular/ hexagonal cast iron or m.s. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick m.s. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ m.s. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. clamp shall be made of 12 mm dia m.s. bar bent to shape as per standard drawing. 82 providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. 83 m.s. tube 84 providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 85 4.0 mm thick glass panes 86 flooring 87 providing and laying c.c. pavement of mix m 25 with ready mixed concrete from batching plant. the ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of engineer incharge. (the panel shuttering work shall be paid for separately). 88 (note: cement content considered in this item is @ 330 kg/cum. excess/less cement used as per design mix is payable/ recoverable separately). 89 kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 90 25 mm thick. 91 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 92 extra for pre finished nosing in treads of steps of kota stone/ sand stone slab. 93 extra for kota stone/ sand stone in treads of steps and risers using single length up to 1.05 metre. 94 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 95 providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 96 size of tile 600x600 mm 97 providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. 98 size of tile 600x600 mm 99 providing and laying 60mm thick faciory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved s;ze, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of engineer in charge. 100 roofing 101 providing and laying brick tiles over mumty roofs, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat: 12.19.1 with common burnt clay f.p.s. (non modular) brick tilesof class designation 10 102 making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over p.v.c. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 103 finishing 104 12 mm cement plaster of mix 105 1:6 (1 cement: 6 coarse sand) 106 15 mm cement plaster on rough side of single or half brick wall of mix: 107 1:6 (1 cement: 6 coarse sand) 108 cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 109 20 mm cement plaster 110 white washing with lime to give an even shade : 111 new work (three or more coats) 112 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 113 new work (two or more coats) over and including water thinnable priming coat with cement primer 114 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 115 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 116 applying priming coat: 117 with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 118 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 119 painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 120 two or more coats on new work 121 painting with black anti corrosive bitumastic paint of approved brand and manufacture to give an even shade : 122 two or more coats on new work 123 water proofing 124 providing and laying water proofing treatment to vertical andhorizontal surfaces of depressed portions of w.c., kitchen and the like consisting of: 125 ist course of applying cement slurry @ 4.4 kg/sqm mixedwith water proofing compound conforming to is 2645 inrecommended proportions including rounding off junction ofvertical and horizontal surface. 126 iind course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. 127 iiird course of applying blown or residual bitumen applied hotat 1.7 kg. per sqm of area. 128 ivth course of 400 micron thick pvc sheet. (overlaps at jointsof pvc sheet should be 100 mm wide and pasted to eachother with bitumen @ 1.7 kg/sqm). 129 providing and laying in situ seven course water proofing treatment with app (atactic poly propylene) modified polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to is : 702, 3rd and 5th layers of roofing membrane app modified polymeric membrane 1.5 mm thick of 2.25 kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron hmhdpe film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron hmhdpe film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately). 130 non shedule items 131 providing and fixing aluminium handles, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 132 150 mm 133 providing and fixing aluminium door buffer of approved make, design and colour with necessary screws etc all complete as directed and specified by the engineer in charge : 134 providing and laying 1st quality ceramic glazed anti skid floortiles of size 300x300 mm (thickness to be specified by the manufacturer) conforming to is:15622 in all colours, shades, sizes as approved over 20 mm thick bed of cement mortar 1: 4 (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc complete in all respects as per specifications/drawings and to the entire satisfaction to the architect. 135 earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 136 all kinds of soil. 137 excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 138 all kinds of soil 139 pipes, cables etc, not exceeding 80 mm dia. 140 pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 141 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 142 roofing 143 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 144 110 mm diameter 145 providing and fixing on wall face unplasticised pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 146 coupler 147 110 mm 148 bend 87.5° 149 110 mm bend 150 shoe (plain) 151 110 mm shoe 152 providing and fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with m.s. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 153 110 mm 154 providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 155 sanitary installations 156 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 157 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 158 providing and fixing white vitreous china pedestal type water closet (european type) with seat and lid, 10 litre low level white vitreous china flushing cistern & c.p. flush bend with fittings & c.i. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 159 w.c. pan with isi marked black solid plastic seat and lid 160 providing and fixing wash basin with c.i. brackets, 15 mm c.p. brass pillar taps, 32 mm c.p. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 161 white vitreous china flat back wash basin size 550x 400 mm with single 15 mm c.p. brass pillar tap 162 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is: 13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 163 kitchen sink with drain board 164 510x1040 mm bowl depth 250 mm 165 extra for using coloured pedestal type w.c pan (european type) with low level cistern of same colour instead of white vitreous china w.c pan and cistern. 166 providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with c.p. brass screws and washers complete. 167 providing and fixing toilet paper holder : 168 vitreous china 169 providing and fixing soil, waste and vent pipes : 170 100 mm dia. 171 centrifugally cast (spun) iron socket & spigot (s&s) pipe as per is: 3989 172 75mm diameter 173 centrifugally cast (spun) iron socketed pipe as per is: 3989 174 providing and fixing m.s. holder bat clamps of approved design to sand cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : 175 for 100 mm dia. pipe 176 for 75 mm dia. pipe 177 providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 178 100 mm 179 sand cast iron s&s as per is 3989 180 75 mm 181 sand cast iron s&s as per is 3989 182 providing and fixing plain bend of required degree. 183 100 mm 184 sand cast iron s&s as per is : 3989 185 75 mm 186 sand cast iron s&s as per is 3989 187 providing and fixing heel rest sanitary bend 188 100 mmdia 189 sand cast iron s&s as per is 3989 190 75 mm dia 191 sand cast iron s&s as per is 3989 192 providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3mm thick,bolts and nuts complete. 193 100x100x100mm 194 sand cast iron s&s as per is 3989 195 75x75x75mm 196 sand cast iron s&s as per is 3989 197 providing and fixing single equal plain junction of required degree 198 100x100x100mm 199 sand cast iron s&s as per is 3989 200 75x75x75mm 201 sand cast iron s&s as per is 3989 202 providing and fixing door piece, insertion rubber washer 3mm thick, bolts & nuts complete : 203 100 mm 204 sand cast iron s&s as per is 3989 205 75 mm 206 sand cast iron s&s as per is 3989 207 providing and fixing terminal guard : 208 100 mm 209 sand cast iron s&s as per is 3989 210 75 mm 211 sand cast iron s&s as per is 3989 212 providing and fixing collar : 213 100 mm 214 sand cast iron s&s as per is 3989 215 75 mm 216 sand cast iron s&s as per is 3989 217 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : 218 100 mm 219 75 mm 220 providing and fixing m.s. stays and clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter : 221 100 mm 222 75 mm 223 providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 224 100 mm inlet and 100 mm outlet 225 sand cast iron s&s as per is: 1729 226 cutting chases in brick masonry walls for following diameter sand cast iron/ centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : 227 100 mm dia 228 painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work : 229 75 mm diameter pipe 230 providing and fixing ptmt waste coupling for wash basin and sink, of approved quality and colour. 231 waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms 232 providing and fixing ptmt bottle trap for wash basin and sink. 233 bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms 234 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 235 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour. 236 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 237 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is: 13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 238 kitchen sink with drain board 239 510x1040 mm bowl depth 250 mm 240 providing and fixing 8mm dia c.p / s.s jet with flexible tube upto1 metre long with s.s triangular plate to eureopean type w.c of quality and make as approved by engineer in charge. 241 providing and fixing g.i. pipes complete with g.i. fittings including trenching & refilling. 242 external work 243 32mmdia nominal bore 244 40mmdia nominal bore 245 water supply 246 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 247 internal work exposed on wall 248 20 mm nominal outer dia pipes 249 25 mm nominal outer dia pipes 250 32 mm nominal outer dia pipes 251 40 mm nominal outer dia pipes 252 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 253 concealed work, including cutting chases and making good the walls etc. 254 15 mm nominal outer dia pipes 255 20 mm nominal outer dia pipes 256 25 mm nominal outer dia pipes 257 32 mm nominal outer dia pipes 258 making connection of g.i. distribution branch with g.i. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 259 25 to 40 mm nominal bore 260 providing and fixing brass stop cock of approved quality : 261 15 mm nominal bore 262 20 mm nominal bore 263 providing and fixing gun metal gate valve with c.i. wheel of approved quality (screwed end) : 264 25mm nominal bore 265 32mm nominal bore 266 40mm nominal bore 267 providing and fixing ball valve (brass) of approved quality, high or low pressure, with plastic floats complete : 268 25 mm nominal bore 269 providing and fixing brass ferrule with c.i. mouth cover including boring and tapping the main : 270 25 mm nominal bore 271 providing and fixing uplasticised pvc connection pipe with brass unions : 272 45 cm length 273 15 mm nominal bore 274 providing and fixing c.p. brass shower rose with 15 or 20 mm inlet : 275 100 mm diameter 276 providing and placing on terrace (at all floor levels) polyethylene water storage tank, is : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 277 rectangular tank 278 providing and fixing c.p. brass bib cock of approved quality conforming to is:8931 : 279 15 mm nominal bore 280 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 281 15 mm nominal bore 282 providing and fixing c.p. brass stop cock (concealed) of standard design and of approved make conforming to is:8931. 283 15 mm nominal bore. 284 providing and fixing c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 285 15 mm nominal bore 286 providing and fixing ptmt grating of approved quality and colour. 287 circular type. 288 100 mm nominal dia. 289 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 290 sewarage & drainage 291 providing, laying and jointing glazed stoneware pipes class sp 1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 292 100 mm diameter 293 150 mm diameter 294 providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all round s.w. pipes including bed concrete as per standard design : 295 100 mm diameter s.w. pipe 296 150 mm diameter s.w. pipe 297 providing and fixing square mouth s.w. gully trap class sp 1 complete with c.i. grating brick masonry chamber with water tight c.i. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70kg as per standard design: 298 180 x 150 mm size p type 299 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 300 constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with r.c.c. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : 301 inside size 90x80 cm and 45 cm deep including c.i. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : 302 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 303 extra for depth for manholes : 304 size 90x80 cm 305 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 306 providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per is : 10910, on 12 mm dia steel bar conforming to is: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 307 making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 308 for pipes 100 to 250 mm diameter 309 providing, laying and jointing non pressure np2 class (light duty)rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 310 150 mm dia rcc pipe 311 250 mm dia rcc pipe 312 non shedule items 313 providing and fixing concealed single leverbath & overhead shower mixer of hindware make and model no.(f360019cp) respectively or equivalent approved make as approved byengineer in charge. 314 providing & fixing sink mixer with swinging casted spout (wall mounted jaquar model con 309 kn)/approved equal with 450mm long copper pipes & brass nuts. 315 providing and fixing c.p. brass grab bar(600mm long) fixed with c.p. brass screwsincluding all fittings complete.jaquar model no. ahs 1507/approve equal. 316 subhead i wiring 317 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. 318 group c 319 wiring for light/ power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 320 wiring for light/ power plug with 4x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 nos. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 321 supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 322 4 module (125 mmx75 mm) 323 supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 324 15/16 a switch 325 3 pin 5/6 a socket outlet 326 telephone socket outlet 327 tv antenna socket outlet 328 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 329 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire 330 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 331 2 x 10 sq. mm + 1 x 6 sq. mm earth wire 332 4 x 4 sq. mm + 2 x 4 sq. mm earth wire 333 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface/ recessed steel/ pvc conduit as required. 334 supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 335 25 mm 336 supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 337 1 or 2 module (75 mmx75 mm) 338 supplying and drawing following pair 0.5 mm dia frls pvc insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ pvc conduit as required. 339 2 pair 340 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 341 20 mm 342 25 mm 343 providing and fixing in position 2mm thick m.s. telephone junction box of size suitable for fixing of following krone tag block with key lock arrangement. also provide clamps for fixing tag blocks. 344 10 pair telephone tag blockwith box 345 supplying, laying of 10 pair unarmoured pvc insulated copper conductor (atc) telephone cable in ground/existing pipes/on wall and making connection with telephone main junction box (mdf) including supports and all accessories as required 346 10 pair cable unarmoured 347 subhead ii supply & installation of fittings 348 supplying of following box type fl. fitting made out of crca sheet finished in antirust treated non yellowing super white stove enamelled paint duly wired with copper wound heavy duty choke starter holder, starter but without lamp complete etc. as reqd. 349 mounting rail for tled lamps 1600 lumens (tmc 501 p 1xt led with essential led 18w tube) 350 sereno 42 watt 2950 lumens philips sp824 p led 30s 5000 gr oa 351 supplying of wall mounted suitable for 1300 lumens complete with ballast & accessories such as wire guard etc. complete as required. 352 15w astra surface & wall mounted 1300 lumens ( philips bn150w led13s 6500 pse od gr ) 353 supplying of wall bracket light fittings suitable for 11 / 13 w cfl lamp. the fitting shall be made up of m.s. powder coated provided with integral ballast, frosted glass and 1 no. 11 / 13 wlamp duly wired upto the connector block complete as required. (decon cat. no.05aam) 354 supplying of ceiling light fittings suitable for 1 x 15/20 w led lamp. the fitting shall be made up of m.s. powder coated provided with electronic ballast, 1 no. 15/20 w led lamp duly wired upto the connector block etc. complete as required. 355 cirrus mini pro 15 / 20 watt & 1100 /1600 lumens (philips sm200c led11s 6500 psu od wh) 356 supplying of bulk head fittings suitable for 10 w led lamp complete with ballast & accessories such as glass, wire guard, 60 w cfl lamp etc. complete as required. 357 endural led bulkhead, 10 w, 600 lumen such as (philips wt202w led6s cw psu s2 pc) 358 supplying of exhaustfan, all complete with mounting ring frame i/c bracket,but without regulator with shutters in the following sizes. (g.e. alsthom, khaitan & havells company) 359 300 mm 4 pole 360 supplying of 1400 mm sweep a.c. electric ceiling fans, capacitor type with double ball bearing complete with 300 mm down rod, canopies, shackles, blades, but without regulator suitable for operation on 230 / 240 volts, 50 hz, single phase, a.c. supply. (crompton, khaitan & havells company) 361 supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 362 installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 363 installation, testing and commissioning of pre wired, light fixture / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 364 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 365 upto 450 mm sweep 366 extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. 367 installation, testing and commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two gls/cfl/ led lamps per fitting, complete with all accessories including connections etc. as required. 368 supplying and fixing call bell/ buzzer suitable for single phase, 230 v, complete as required. 369 subhead iii distribution board 370 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/ isolator) 371 6 way (4 + 18), double door 372 supplying and fixing following rating, four pole, 415 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 373 100 a 374 supplying and fixing following rating, four pole, (three phase and neutral), 415 v, residual current circuit breaker (rccb), having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. 375 63 a 376 supplying and fixing following rating, double pole, 240 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 377 40 amps 378 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 379 12 way , double door 380 16 way , double door 381 supplying and fixing following rating, double pole, (single phase and neutral), 240 v, residual current circuit breaker (rccb), having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. 382 25 a 383 40 a 384 supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 385 single pole 386 subhead iv earthing 387 earthing with g.i. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 388 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re filling as required. 389 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 390 subhead v street lighting on building 391 supplying, installing, testing and commissioning of 2 x 36w general purpose flourescent street light fittings with sheet aluminium housing and uv stabilized acrylic cover complete with chokes, starter holders, condensers, reflector cover etc. as reqd. (philips cat no. trc 33 / 236 hpf) (to be fixed directly on wall of building) 392 supplying and fixing of 32 mm dia x 2.00 meter long g.i. pipe (medium class) bracket for mounting of fluorescent / hpmv / hpsv street light fitting on pole including bending the pipe to the required shape, 2 nos. 40 mm x 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. 393 supply of following sizes of frls 1.1 kv stranded compact circular aluminium conductor screened with extruded semi conducting compound, xlpe insulated,al round wire armoured & overall pvc sheathed cableconforming to is to is 7098 (part i) with latest amendments 394 2 x 4 sq.mm 395 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. 396 upto 35 sq. mm 397 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc/ hume/ metal pipe as required. 398 upto 35 sq. mm 399 laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required. 400 upto 35 sq. mm (clamped with 1mm thick saddle) 401 supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required. 402 2 x 6 sq. mm (19mm) 403 supply & fixing of 150x200 mm 60mm deep ms junction box recess or surface on wall with 3mm bakalite cover15 overlapping 15 all sides of junction box & housing 4way 32amps bakelie connector to terminate incoming & outgoing armoured cable & & wiring the light fixture with 3x1.5 sq mm pvc insulated coppwer wire including interconnection ets as reqired .( cost of termination of armoured cable with gland is not to be included as the same is payable under separate item no 5.07 of this subhead) 404 providing, laying and fixing following dia rcc pipe np2 class (light duty) in ground complete with rcc collars, jointing withcement mortar1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required. 405 100 mm dia 406 subhead vi lightning conductor 407 providing and fixing of lightning conductor finial, made of 25mm dia 300 mm long, g.i. tube, having single prong at top, with85 mm dia 6 mm thick g.i. base plate including holes etc.complete as required. 408 jointing copper / g.i. tape (with another copper/ g i tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 409 fixing of copper/ g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for horizontal run) 410 fixing of copper/ g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for vertical run) 411 providing and fixing testing joint, made of 20 mm x 3 mm thickg.i. strip, 125 mm long, with 4 nos. of g.i. bolts, nuts, chucknuts and spring washers etc. complete as required. 412 laying copper/ g.i. tape 32 mm x 6 mm from earth electrodedirectly in ground as required 413 earth work 414 earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 415 all kinds of soil 416 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 417 supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 418 excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 419 concrete work 420 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 421 1:5:10 (1 cement : 5 coarse sand (zone iii) : 10 graded stone aggregate 40 mm nominal size) 422 providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : 423 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). 424 providing and laying damp proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone iii): 4 graded stone aggregate 12.5mm nominal size) 425 providing & applying a coat of residual petroleum bitumen of grade of vg 10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 426 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 427 reinforcedcementconcrete 428 centering and shuttering including strutting, propping etc. and removal of form for all heights: 429 foundations, footings, bases of columns, etc. for mass concrete 430 walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc 431 columns, pillars, piers, abutments, posts and struts 432 small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like 433 edges of slabs and breaks in floors and walls 434 under 20 cms wide 435 suspended floors, roofs, landings, balconies and access platform. 436 lintels, beams, plinth beams, girders, bressumers and cantilevers. 437 providing precast cement concrete jali 1:2:4 (1 cement : 2 coarse sand(zone iii) : 4 graded stone aggregate 6mm nominal size), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing with cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits. 438 50 mm thick 439 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 440 thermo mechanically treated bars of grade fe 500d or more. 441 add for plaster drip course/ groove in plastered surface or moulding to r.c.c. projections. 442 providing and laying in position machine batched and machine mixed design mix m 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per is: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of engineer in charge.“(note : cement content considered in this item is @ 330 kg/cum.“excess/ less cement used as per design mix is payable/recoverable separately). 443 all works upto plinth level 444 all works above plinth level upto floor v level 445 add for using extra cement in the items of design mix over and above the specified cement content therein. 446 brick work 447 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in foundation and plinth in: 448 cement mortar 1:6 (1 cement : 6 coarse sand) 449 providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick aac blocks in super structure above plinth level up to floor v level with rcc band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of engineer in charge. (the payment of rcc band and reinforcement shall be made for seperately).: 450 half brick masonry with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level. 451 cement mortar 1:4 (1 cement :4 coarse sand) 452 extra for providing and placing in position 2 nos 6mm dia. m.s. bars at every third course of half brick masonry. 453 brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand). 454 marble work 455 providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 456 raj nagar plain white marble/ udaipur green marble/ zebra black marble 457 area of slab over 0.50 sqm 458 granite of any colour and shade 459 area of slab over 0.50 sqm 460 providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer in charge. 461 marble work 462 granite work 463 extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 464 wood work & pvc work 465 float glass panes 466 4mm thick glass pane (weight not less than 10 kg/sqm 467 extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. (area of opening for glass panes excluding portion inside rebate shall be measured). 468 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 469 35 mm thick including isi marked stainless steel butt hinges with necessary screws 470 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 471 extra for cutting rebate in flush door shutters (total area of the shutter to be measured). 472 providing and fixing wire gauge shutters using galvanized m.s. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 473 35 mm thick shutters 474 kiln seasoned and chemically treated hollock wood 475 providing and fixing fly proof galvanized m.s. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. 476 with 12 mm mild steel u beading 477 providing and fixing isi marked oxidised m.s. single acting spring hinges with necessary screws etc. complete : 478 150 mm 479 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete. 480 250 mm weighing not less than 150 gms 481 providing and fixing aluminium sliding door bolts, isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 482 250x16 mm 483 providing and fixing aluminium tower bolts, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 484 200x10 mm 485 providing and fixing aluminium hanging floor door stopper, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. 486 twin rubber stopper 487 providing and fixing factory made upvc white colour sliding glazed window upto 1.50 m in height dimension comprising of upvc multi chambered frame with in built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to upvc profile), appropriate dimension of upvc extruded glazing beads and upvc extruded interlocks, epdm gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), g.i fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of engineer in charge. (single / double glass panes, wire mesh and silicon sealent shall be paid separately). variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 488 three track three panels sliding window with fly proof s.s wire mesh (two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (area of window above 1.75 sqm). 489 steel work 490 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 491 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 492 providing and fixing t iron frames for doors, windows and ventilators of mild steel tee sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 493 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 494 providing and fixing circular/ hexagonal cast iron or m.s. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick m.s. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ m.s. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. clamp shall be made of 12 mm dia m.s. bar bent to shape as per standard drawing. 495 providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. 496 m.s. tube 497 providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 498 4.0 mm thick glass panes 499 flooring 500 providing and laying c.c. pavement of mix m 25 with ready mixed concrete from batching plant. the ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of engineer incharge. (the panel shuttering work shall be paid for separately). 501 (note: cement content considered in this item is @ 330 kg/cum. excess/less cement used as per design mix is payable/ recoverable separately). 502 kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 503 25 mm thick. 504 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 505 extra for pre finished nosing in treads of steps of kota stone/ sand stone slab. 506 extra for kota stone/ sand stone in treads of steps and risers using single length up to 1.05 metre. 507 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 508 providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 509 size of tile 600x600 mm 510 providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. 511 size of tile 600x600 mm 512 providing and laying 60mm thick faciory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved s;ze, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of engineer in charge. 513 roofing 514 providing and laying brick tiles over mumty roofs, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat: 12.19.1 with common burnt clay f.p.s. (non modular) brick tilesof class designation 10 515 making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over p.v.c. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 516 finishing 517 12 mm cement plaster of mix 518 1:6 (1 cement: 6 coarse sand) 519 15 mm cement plaster on rough side of single or half brick wall of mix: 520 1:6 (1 cement: 6 coarse sand) 521 cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 522 20 mm cement plaster 523 white washing with lime to give an even shade : 524 new work (three or more coats) 525 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 526 new work (two or more coats) over and including water thinnable priming coat with cement primer 527 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 528 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 529 applying priming coat: 530 with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 531 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 532 painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 533 two or more coats on new work 534 painting with black anti corrosive bitumastic paint of approved brand and manufacture to give an even shade : 535 two or more coats on new work 536 water proofing 537 providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of w.c., kitchen and the like consisting of: 538 ist course of applying cement slurry @ 4.4 kg/sqm mixedwith water proofing compound conforming to is 2645 inrecommended proportions including rounding off junction of vertical and horizontal surface. 539 iind course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. 540 iiird course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. 541 ivth course of 400 micron thick pvc sheet. (overlaps at joints of pvc sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). 542 providing and laying in situ seven course water proofing treatment with app (atactic poly propylene) modified polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to is : 702, 3rd and 5th layers of roofing membrane app modified polymeric membrane 1.5 mm thick of 2.25 kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron hmhdpe film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron hmhdpe film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately). 543 non shedule items 544 providing and fixing aluminium handles, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 545 150 mm 546 providing and fixing aluminium door buffer of approved make, design and colour with necessary screws etc all complete as directed and specified by the engineer in charge : 547 providing and laying 1st quality ceramic glazed anti skid floortiles of size 300x300 mm (thickness to be specified by the manufacturer) conforming to is:15622 in all colours, shades, sizes as approved over 20 mm thick bed of cement mortar 1: 4 (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc complete in all respects as per specifications/drawings and to the entire satisfaction to the architect. 548 earth work 549 earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 550 all kinds of soil. 551 excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 552 all kinds of soil 553 pipes, cables etc, not exceeding 80 mm dia. 554 pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 555 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 556 roofing 557 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 558 110 mm diameter 559 providing and fixing on wall face unplasticised pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 560 coupler 561 110 mm 562 bend 87.5° 563 110 mm bend 564 shoe (plain) 565 110 mm shoe 566 providing and fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with m.s. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 567 110 mm 568 providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 569 sanitary installations 570 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 571 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 572 providing and fixing white vitreous china pedestal type water closet (european type) with seat and lid, 10 litre low level white vitreous china flushing cistern & c.p. flush bend with fittings & c.i. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 573 w.c. pan with isi marked black solid plastic seat and lid 574 providing and fixing wash basin with c.i. brackets, 15 mm c.p. brass pillar taps, 32 mm c.p. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 575 white vitreous china flat back wash basin size 550x 400 mm with single 15 mm c.p. brass pillar tap 576 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is: 13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 577 kitchen sink with drain board 578 510x1040 mm bowl depth 250 mm 579 extra for using coloured pedestal type w.c pan (european type) with low level cistern of same colour instead of white vitreous china w.c pan and cistern. 580 providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with c.p. brass screws and washers complete. 581 providing and fixing toilet paper holder : 582 vitreous china 583 providing and fixing soil, waste and vent pipes : 584 100 mm dia. 585 centrifugally cast (spun) iron socket & spigot (s&s) pipe as per is: 3989 586 75mm diameter 587 centrifugally cast (spun) iron socketed pipe as per is: 3989 588 providing and fixing m.s. holder bat clamps of approved design to sand cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : 589 for 100 mm dia. pipe 590 for 75 mm dia. pipe 591 providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 592 100 mm 593 sand cast iron s&s as per is 3989 594 75 mm 595 sand cast iron s&s as per is 3989 596 providing and fixing plain bend of required degree. 597 100 mm 598 sand cast iron s&s as per is : 3989 599 75 mm 600 sand cast iron s&s as per is 3989 601 providing and fixing heel rest sanitary bend 602 100 mmdia 603 sand cast iron s&s as per is 3989 604 75 mm dia 605 sand cast iron s&s as per is 3989 606 providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3mm thick,bolts and nuts complete. 607 100x100x100mm 608 sand cast iron s&s as per is 3989 609 75x75x75mm 610 sand cast iron s&s as per is 3989 611 providing and fixing single equal plain junction of required degree 612 100x100x100mm 613 sand cast iron s&s as per is 3989 614 75x75x75mm 615 sand cast iron s&s as per is 3989 616 providing and fixing door piece, insertion rubber washer 3mm thick, bolts & nuts complete : 617 100 mm 618 sand cast iron s&s as per is 3989 619 75 mm 620 sand cast iron s&s as per is 3989 621 providing and fixing terminal guard : 622 100 mm 623 sand cast iron s&s as per is 3989 624 75 mm 625 sand cast iron s&s as per is 3989 626 providing and fixing collar : 627 100 mm 628 sand cast iron s&s as per is 3989 629 75 mm 630 sand cast iron s&s as per is 3989 631 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : 632 100 mm 633 75 mm 634 providing and fixing m.s. stays and clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter : 635 100 mm 636 75 mm 637 providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 638 100 mm inlet and 100 mm outlet 639 sand cast iron s&s as per is: 1729 640 cutting chases in brick masonry walls for following diameter sand cast iron/ centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : 641 100 mm dia 642 painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work : 643 75 mm diameter pipe 644 providing and fixing ptmt waste coupling for wash basin and sink, of approved quality and colour. 645 waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms 646 providing and fixing ptmt bottle trap for wash basin and sink. 647 bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms 648 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 649 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour. 650 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 651 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is: 13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 652 kitchen sink with drain board 653 510x1040 mm bowl depth 250 mm 654 providing and fixing 8mm dia c.p / s.s jet with flexible tube upto1 metre long with s.s triangular plate to eureopean type w.c of quality and make as approved by engineer in charge. 655 providing and fixing g.i. pipes complete with g.i. fittings including trenching & refilling. 656 external work 657 32mmdia nominal bore 658 40mmdia nominal bore 659 water supply 660 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 661 internal work exposed on wall 662 20 mm nominal outer dia pipes 663 25 mm nominal outer dia pipes 664 32 mm nominal outer dia pipes 665 40 mm nominal outer dia pipes 666 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 667 concealed work, including cutting chases and making good the walls etc. 668 15 mm nominal outer dia pipes 669 20 mm nominal outer dia pipes 670 25 mm nominal outer dia pipes 671 32 mm nominal outer dia pipes 672 making connection of g.i. distribution branch with g.i. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 673 25 to 40 mm nominal bore 674 providing and fixing brass stop cock of approved quality : 675 15 mm nominal bore 676 20 mm nominal bore 677 providing and fixing gun metal gate valve with c.i. wheel of approved quality (screwed end) : 678 25mm nominal bore 679 32mm nominal bore 680 40mm nominal bore 681 providing and fixing ball valve (brass) of approved quality, high or low pressure, with plastic floats complete : 682 25 mm nominal bore 683 providing and fixing brass ferrule with c.i. mouth cover including boring and tapping the main : 684 25 mm nominal bore 685 providing and fixing uplasticised pvc connection pipe with brass unions : 686 45 cm length 687 15 mm nominal bore 688 providing and fixing c.p. brass shower rose with 15 or 20 mm inlet : 689 100 mm diameter 690 providing and placing on terrace (at all floor levels) polyethylene water storage tank, is : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 691 rectangular tank 692 providing and fixing c.p. brass bib cock of approved quality conforming to is:8931 : 693 15 mm nominal bore 694 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 695 15 mm nominal bore 696 providing and fixing c.p. brass stop cock (concealed) of standard design and of approved make conforming to is:8931. 697 15 mm nominal bore. 698 providing and fixing c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 699 15 mm nominal bore 700 providing and fixing ptmt grating of approved quality and colour. 701 circular type. 702 100 mm nominal dia. 703 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 704 sewarage & drainage 705 providing, laying and jointing glazed stoneware pipes class sp 1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 706 100 mm diameter 707 150 mm diameter 708 providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all round s.w. pipes including bed concrete as per standard design : 709 100 mm diameter s.w. pipe 710 150 mm diameter s.w. pipe 711 providing and fixing square mouth s.w. gully trap class sp 1 complete with c.i. grating brick masonry chamber with water tight c.i. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70kg as per standard design: 712 180 x 150 mm size p type 713 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 714 constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with r.c.c. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : 715 inside size 90x80 cm and 45 cm deep including c.i. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : 716 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 717 extra for depth for manholes : 718 size 90x80 cm 719 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 720 providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per is : 10910, on 12 mm dia steel bar conforming to is: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 721 making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 722 for pipes 100 to 250 mm diameter 723 providing, laying and jointing non pressure np2 class (light duty)rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 724 150 mm dia rcc pipe 725 250 mm dia rcc pipe 726 non shedule items 727 providing and fixing concealed single leverbath & overhead shower mixer of hindware make and model no.(f360019cp) respectively or equivalent approved make as approved byengineer in charge. 728 providing & fixing sink mixer with swinging casted spout (wall mounted jaquar model con 309 kn)/approved equal with 450mm long copper pipes & brass nuts. 729 providing and fixing c.p. brass grab bar(600mm long) fixed with c.p. brass screwsincluding all fittings complete.jaquar model no. ahs 1507/approve equal. 730 subhead i wiring 731 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. 732 group c 733 wiring for light/ power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 734 wiring for light/ power plug with 4x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 nos. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 735 supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 736 4 module (125 mmx75 mm) 737 supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 738 15/16 a switch 739 3 pin 5/6 a socket outlet 740 telephone socket outlet 741 tv antenna socket outlet 742 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 743 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire 744 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 745 2 x 10 sq. mm + 1 x 6 sq. mm earth wire 746 4 x 4 sq. mm + 2 x 4 sq. mm earth wire 747 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface/ recessed steel/ pvc conduit as required. 748 supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 749 25 mm 750 supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 751 1 or 2 module (75 mmx75 mm) 752 supplying and drawing following pair 0.5 mm dia frls pvc insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ pvc conduit as required. 753 2 pair 754 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 755 20 mm 756 25 mm 757 providing and fixing in position 2mm thick m.s. telephone junction box of size suitable for fixing of following krone tag block with key lock arrangement. also provide clamps for fixing tag blocks. 758 10 pair telephone tag blockwith box 759 supplying, laying of 10 pair unarmoured pvc insulated copper conductor (atc) telephone cable in ground/existing pipes/on wall and making connection with telephone main junction box (mdf) including supports and all accessories as required 760 10 pair cable unarmoured 761 subhead ii supply & installation of fittings 762 supplying of following box type fl. fitting made out of crca sheet finished in antirust treated non yellowing super white stove enamelled paint duly wired with copper wound heavy duty choke starter holder, starter but without lamp complete etc. as reqd. 763 mounting rail for tled lamps 1600 lumens (tmc 501 p 1xt led with essential led 18w tube) 764 sereno 42 watt 2950 lumens philips sp824 p led 30s 5000 gr oa 765 supplying of wall mounted suitable for 1300 lumens complete with ballast & accessories such as wire guard etc. complete as required. 766 15w astra surface & wall mounted 1300 lumens ( philips bn150w led13s 6500 pse od gr ) 767 supplying of wall bracket light fittings suitable for 11 / 13 w cfl lamp. the fitting shall be made up of m.s. powder coated provided with integral ballast, frosted glass and 1 no. 11 / 13 wlamp duly wired upto the connector block complete as required. (decon cat. no.05aam) 768 supplying of ceiling light fittings suitable for 1 x 15/20 w led lamp. the fitting shall be made up of m.s. powder coated provided with electronic ballast, 1 no. 15/20 w led lamp duly wired upto the connector block etc. complete as required. 769 cirrus mini pro 15 / 20 watt & 1100 /1600 lumens (philips sm200c led11s 6500 psu od wh) 770 supplying of bulk head fittings suitable for 10 w led lamp complete with ballast & accessories such as glass, wire guard, 60 w cfl lamp etc. complete as required. 771 endural led bulkhead, 10 w, 600 lumen such as (philips wt202w led6s cw psu s2 pc) 772 supplying of exhaustfan, all complete with mounting ring frame i/c bracket,but without regulator with shutters in the following sizes. (g.e. alsthom, khaitan & havells company) 773 300 mm 4 pole 774 supplying of 1400 mm sweep a.c. electric ceiling fans, capacitor type with double ball bearing complete with 300 mm down rod, canopies, shackles, blades, but without regulator suitable for operation on 230 / 240 volts, 50 hz, single phase, a.c. supply. (crompton, khaitan & havells company) 775 supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 776 installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 777 installation, testing and commissioning of pre wired, light fixture / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 778 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 779 upto 450 mm sweep 780 extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. 781 installation, testing and commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two gls/cfl/ led lamps per fitting, complete with all accessories including connections etc. as required. 782 supplying and fixing call bell/ buzzer suitable for single phase, 230 v, complete as required. 783 subhead iii distribution board 784 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/ isolator) 785 6 way (4 + 18), double door 786 supplying and fixing following rating, four pole, 415 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 787 100 a 788 supplying and fixing following rating, four pole, (three phase and neutral), 415 v, residual current circuit breaker (rccb), having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. 789 63 a 790 supplying and fixing following rating, double pole, 240 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 791 40 amps 792 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 793 12 way , double door 794 16 way , double door 795 supplying and fixing following rating, double pole, (single phase and neutral), 240 v, residual current circuit breaker (rccb), having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. 796 25 a 797 40 a 798 supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 799 single pole 800 subhead iv earthing 801 earthing with g.i. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 802 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re filling as required. 803 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 804 subhead v street lighting on building 805 supplying, installing, testing and commissioning of 2 x 36w general purpose flourescent street light fittings with sheet aluminium housing and uv stabilized acrylic cover complete with chokes, starter holders, condensers, reflector cover etc. as reqd. (philips cat no. trc 33 / 236 hpf) (to be fixed directly on wall of building) 806 supplying and fixing of 32 mm dia x 2.00 meter long g.i. pipe (medium class) bracket for mounting of fluorescent / hpmv / hpsv street light fitting on pole including bending the pipe to the required shape, 2 nos. 40 mm x 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. 807 supply of following sizes of frls 1.1 kv stranded compact circular aluminium conductor screened with extruded semi conducting compound, xlpe insulated,al round wire armoured & overall pvc sheathed cableconforming to is to is 7098 (part i) with latest amendments 808 2 x 4 sq.mm 809 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. 810 upto 35 sq. mm 811 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc/ hume/ metal pipe as required. 812 upto 35 sq. mm 813 laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required. 814 upto 35 sq. mm (clamped with 1mm thick saddle) 815 supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required. 816 2 x 6 sq. mm (19mm) 817 supply & fixing of 150x200 mm 60mm deep ms junction box recess or surface on wall with 3mm bakalite cover15 overlapping 15 all sides of junction box & housing 4way 32amps bakelie connector to terminate incoming & outgoing armoured cable & & wiring the light fixture with 3x1.5 sq mm pvc insulated coppwer wire including interconnection ets as reqired .( cost of termination of armoured cable with gland is not to be included as the same is payable under separate item no 5.07 of this subhead) 818 providing, laying and fixing following dia rcc pipe np2 class (light duty) in ground complete with rcc collars, jointing withcement mortar1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required. 819 100 mm dia 820 subhead vi lightning conductor 821 providing and fixing of lightning conductor finial, made of 25mm dia 300 mm long, g.i. tube, having single prong at top, with85 mm dia 6 mm thick g.i. base plate including holes etc.complete as required. 822 jointing copper / g.i. tape (with another copper/ g i tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 823 fixing of copper/ g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for horizontal run) 824 fixing of copper/ g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for vertical run) 825 providing and fixing testing joint, made of 20 mm x 3 mm thickg.i. strip, 125 mm long, with 4 nos. of g.i. bolts, nuts, chucknuts and spring washers etc. complete as required. 826 laying copper/ g.i. tape 32 mm x 6 mm from earth electrodedirectly in ground as required 827 earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 828 all kinds of soil 829 excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 830 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 831 supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 832 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone iii) : 10 graded stone aggregate 40 mm nominal size) 833 providing and laying in position machine batched and machine mixed design mix m 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per is: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of engineer in charge.“(note : cement content considered in this item is @ 330 kg/cum.“excess/ less cement used as per design mix is payable/recoverable separately). 834 upto plinth level 835 (i) r.c.c. work in footing 836 (ii) r.c.c. work in beam 837 (iii) r.c.c. work in columns 838 above plinth to floor v lvl 839 same as above but r.c.c. work abive plinth lvl. 840 (i) r.c.c. work in lintel 841 (ii) r.c.c. work in beam 842 (iii) r.c.c. work in columns 843 (iv) r.c.c. work in slab 844 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. thermo mechanically treated bars of grade fe 500d or more. 845 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. thermo mechanically treated bars of grade fe 500 d or more. 846 add for plaster drip course/ groove in plastered surface or moulding tor.c.c. projections. 847 centering and shuttering including strutting, propping etc. and removal of form for all heights : 848 foundations, footings, bases of columns, etc. for mass concrete. 849 suspended floors, roofs, landings, balconies and access platform. 850 lintels, beams, plinth beams, girders, bressumers and cantilevers. 851 columns,pillars, piers, abutments, posts and struts. 852 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in foundation and plinth in: 853 cement mortar 1:6 (1 cement : 6 coarse sand) 854 providing and laying damp proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone iii): 4 graded stone aggregate 12.5mm nominal size) 855 providing & applying a coat of residual petroleum bitumen of grade of vg 10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 856 providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick aac blocks in super structure above plinth level up to floor v level with rcc band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of engineer in charge. (the payment of rcc band and reinforcement shall be made for seperately). 857 half brick masonry with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in foundations and plinth in : cement mortar 1:4 (1 cement : 4 coarse sand) 858 extra for providing and placing in position 2 nos 6mm dia. m.s. bars at every third course of half brick masonry. 859 providing and laying in situ seven course water proofing treatment with app (atactic poly propylene) modified polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to is : 702, 3rd and 5th layers of roofing membrane app modified polymeric membrane 1.5 mm thick of 2.25 kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron hmhdpe film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron hmhdpe film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately). 860 providing and laying brick tiles over mumty roofs, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat: 12.19.1 with common burnt clay f.p.s. (non modular) brick tilesof class designation 10 861 providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to is : 14616 and tads 15:2001 (part b), including isi marked m.s. pressed butt hinges bright finished of required size with necessary screws, all complete as per directions of engineerin charge and panelling with panels of : 12 mm thick one side pre laminated particle board (decorative lamination on one side and other sides balancing lamination) grade 1, medium density flat pressed, three layer particle board fpt i or graded wood particle board fpt 1 conforming to is : 3087 bonded with bwp type synthetic resin adhesive as per is : 848 and pre laminated conforming to is : 12823, grade 1, type ii marked : 862 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 863 providing and fixing t iron frames for doors, windows and ventilators of mild steel tee sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer 864 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 865 providing and fixing factory made upvc white colour fixed glazed windows/ ventilators comprising of upvc multi chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to upvc profile), ,upvc extruded glazing beads of appropriate dimension, epdm gasket, g.i fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of engineer in charge. (single / double glass panes and silicon sealant shall be paid separately). variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 866 fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. 867 providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes. 868 providing and fixing wire gauge shutters using galvanized m.s. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 869 30 mm thick shutters with isi marked m.s. pressed butt hinges bright finished of required size second class teak wood 870 providing and fixing factory made upvc white colour sliding glazed window upto 1.50 m in height dimension comprising of upvc multi chambered frame with in built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to upvc profile), appropriate dimension of upvc extruded glazing beads and upvc extruded interlocks, epdm gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), g.i fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of engineer in charge. (single / double glass panes, wire mesh and silicon sealent shall be paid separately). variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 871 three track three panels sliding window with fly proof s.s wire mesh (two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (area of window above 1.75 sqm). 872 15 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement: 6 coarse sand) 873 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) 874 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 875 providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. size of tile 600x600 mm. 876 providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. size of tile 600x600 mm 877 providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. area of slab upto 0.50 sqm 878 providing and laying ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 879 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 880 providing edge moulding to 18mm thick marble stone counters, vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer in charge. 881 granite work 882 extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete. 883 extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/granite/stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 884 steel painting: 885 (a) with ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works. 886 (b) painting withsynthetic enamel paint of approvedbrandand manufactureto give an even shade:two or more coats on new work. 887 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : new work (two or more coats) over and including water thinnable priming coat with cement primer. 888 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade. new work (two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). 889 providing and fixing isi marked oxidised m.s. single acting spring hingeswith necessary screws etc. complete : 890 150 mm 891 providing and fixing oxidised m.s. hasp and staple (safety type)conforming to is : 363 with necessary screws etc. complete : 892 90 mm 893 providing and fixing special quality bright finished brass cupboard orward robe locks with four levers of approved quality including necessaryscrews etc. complete. 894 75 mm 895 providing and fixing wooden moulded corner beading of triangular shape to the junction of panelling etc. with iron screws, plugs and priming coat on unexposed surface etc. complete 2nd class teak wood. 896 50x50 mm (base and height) 897 providing and fixing aluminium sliding door bolts, isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 898 250x16 mm 899 providing and fixing aluminium tower bolts, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 900 200x10 mm 901 providing and fixing aluminium handles, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 902 125 mm 903 providing and fixing aluminium hanging floor door stopper isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. twin rubber stopper 904 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 905 25 mm thick (for cupboard) including isi marked nickel plated bright finished m.s. piano hinges with necessary screws 906 providing and fixing pre laminated flat pressed 3 layer (medium density) particle board or graded wood particle board is : 3087 marked, with one side decorative and other side balancing lamination grade i, type ii exterior grade is : 12823 marked, in shelves with screws and fittings wherever required, edges to be painted with polyurethane primer (fittings to be paid separately). 907 float glass panes 4.0 mm thick glass panes (weight not less than 10 kg/sqm). 908 providing and fixing white vitreous china pedestal type water closet (european type w.c. pan) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. 909 w.c. pan with isi marked white solid plastic seat and lid 910 providingandfixing p.v.c. waste pipe forsink or wash basin including pvc waste fittings complete. 911 flexible pipe 912 40 mm dia(for sink and urinal) 913 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is: 13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 914 kitchen sink with drain board 915 510x1040 mm bowl depth 250 mm 916 providing and fixing wash basin with c.i.brackets, 15 mm c.p. brass pillar taps, 32 mm c.p. brass waste of standard pattern,includingpainting of fittings and brackets, cutting and making good the walls wherever required 917 white vitreous china wash basin size 550x400 mm with single 15 mm c.p. brass pillar tap 918 providing and fixing cp brass 32mm size bottle trap of bapproved quality & make and as per the direction of engineerin charge. 919 providing & fixing c.p. brass health faucet for ablution with 1 meter long pvc tube, hand shower, couplings, wall hook and other accessories. 920 providing & fixing cp brass overhead shower with shower arm, hand shower 95mm dia single lever concealed deusch mixer with provision for connection to overhead shower and easy flex tube with accessories complete i allrespect 921 providing & fixing c.p. brass waste coupling for pvc waste pipe. 922 providing & fixing 600 x 450 mm bevelled edge mirror of superiorglass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with c.p. brass screws and washers complete. 923 providing & fixing toilet paper holder. 924 viterous china 925 providing and fixing of c. p. brass towel rail 600 x 20 mm size complete with c.p. brass brackets 926 providing and fixing of c. p. brass towel ring complete with c.p. brass brackets 927 providing and fixing cp brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 928 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor soil, waste, and vent, type b as per is : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors),reducers, wc connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382. 929 the pipes will be supported with threaded g i rods & u clamps with nuts, washers etc on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg in charge at site. 930 110 mm dia (wall thickness 3.2 to 3.8 mm) 931 75 mm dia (wall thickness 3.2 to 3.8 mm) 932 providing, fixing, jointing and testing in position isi marked (is:4985) upvc pipes of min 6 kg/ sqcm rating with fitting for waste pipe from fixtures to floor trap including reduces, enlarger, socket, couplers, bends, tees etc including fixing at wall/ ceiling level supported by clamp & hangers etc. cutting holes in wall/ floors/ slabs and making good the same with cement concrete 1:2:4 complete as required. 933 32 mm dia. 934 providing & fixing upvc floor trap of self cleansing designwith stainless steel grating complete in all respects. 935 multi floor trap (5 ht) with height raiser and branch saddle strip of 50/75 mm outlet 936 plain floor trap (4 ht) with 50 / 75 outlet and with height raiser 937 p trap type floor trap 110 x 75 mm 938 extra for providing & fixing 125 mm dia c.p. grating in place of c.i. grating over floor traps. 939 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor rain water disposal, type b as peris : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors), reducers, couplers, expansion joints / bellows, cowels, clamps, rubber rings, ms gratings over pipes of bell mouth construction with epoxy painting etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382. 940 the pipes will be supported with threaded g i rods & clamps on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg in charge at site. 941 110 mm dia 942 making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over p.v.c. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 943 providing&fixing15 mm nominal bore45 cm long unplasticised pvc connection pipewith brass unions. 944 45 cm length 945 15 mm nominal bore 946 providing and fixing c.p brass bib cock of approved qualityconforming to is standards is: 8931. 947 15 mm nominal bore 948 providing and fixing c.p brass long nose bib cock of approved qualityconforming to is standardsandweighing notlessthan 810 gms. 949 15 mm nominal bore 950 providing & fixing 15 mm nominal bore c.p brass angle valve for basin mixer and geyser points of approved quality conformingto is8931. 951 15 mm nominal bore 952 constructing brick masonry chamber 300 x 300x500mm, insidewithf.p.s. brick work in cement mortar 1: 4 (1 cement : 4 coarse sand) for stopcock, withc. i. surface box 100 x 100 x 75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4mix (1cement : 2 coarse sand:4 grade stone aggregate 20mm nominal size); necessary excavation, foundationconcrete 1:5:10 (1 cement :5 fine sand: 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar1 : 3 (1 cement : 3 coarse sand )12mmthick finished with a floatingcoatof neat cementcomplete as per standard design 953 with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 954 providing & fixing g.i. unoun in g.i. pipe including cutting and threading the pipe & making long screws etc. complete. 955 15mm dia nominal bore 956 20mm dia nominal bore 957 25mm dia nominal bore 958 32mm dia nominal bore 959 40mm dia nominal bore 960 cutting holes up to 30 x 30 cm in walls including making good the same: 961 with common burnt clay f.p.s. (non modular) bricks 962 providing, fixing chlorinated polyvinyl chloride (cpvc) pipescts sdr 11, class 1 cpvc pipes (pressure rating 28 kg/cm2 at 23oc and 7 kg/cm2 at 82oc) confirming to is : 15778 2007, astm d 2846, havingthermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 963 internal work exposed on wall 964 20mm nominal outer dia pipes 965 25mm nominal outer dia pipes 966 32mm nominal outer dia pipes 967 40mm nominal outer dia pipes 968 providing, fixing chlorinated polyvinyl chloride (cpvc) pipescts sdr 11, class 1 cpvc pipes (pressure rating 28 kg/cm2 at 23oc and 7 kg/cm2 at 82oc) confirming to is : 15778 2007, astm d 2846, havingthermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 969 concealed work including cutting chase and making good the wall etc. 970 15mm nominal outer dia pipes 971 20mm nominal outer dia pipes 972 providing and placing on terrace (at all floor levels) polyethylene water storage tank, is : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 973 circular tank 974 providing & fixing of hand lever operated forged brass body full way ball valve type isolating valve having forged brass hard chrome plated mirror finish ball, steel handle with pvc grip, teflon seat, screwed ends tested to a pressure of 15 kg/sqcm complete. 975 15 mm nominal bore 976 20 mm nominal bore 977 a) 25 mm dia 978 40 mm nominal bore 979 providing & fixing brass ball float valvewith bronzefloats of approved quality complete. 980 20 mm nominal dia 981 providing & fixing of medium class g.i.spout up to 300 mm. length including cutting and making good the walls and floors etc. as required. 982 a) 25 mm dia 983 sub head (i) : internal wiring 984 point wiring in pvc conduit, with modular type switch : 985 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. 986 group c 987 wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed pvc conduit, and earthing the point with 1.5 sq. mm frls pvc insulated copper conductor single core cable etc. as required. 988 group c 989 twin control point wiring in pvc conduit, with modular type switch : 990 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way modular switch, modular switch, suitable m.s. box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. 991 power plug wiring in pvc conduit (2 x 4 sq.mm.) : 992 wiring for light/ power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 993 circuit / sub main wiring in pvc conduit : 994 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 995 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire. 996 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire. 997 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire 998 2 x 10 sq.mm. + 1 x 6 sq.mm. earth wire 999 4 x 10 sq.mm. + 2 x 6 sq.mm. earth wire 1000 s/f light plug point modular type accessories : 1001 supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 a modular socket outlet and 5/6 a modular switch, connections etc. as required 1002 s/f power plug point modular type accessories : 1003 supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 a modular socket outlet and 15/16 a modular switch, connections etc. as required. 1004 supplying and fixing 20 amps, 240 volts, spn, industrial type socket outlet, with 2 poles and earth metal enclosedplug top alongwith 20amps. c curve, sp mcb in sheet steel enclosure, on surface or in recess, with chainedmetal cover for the socket outlet, and complete with connections, testingandcommissioning etc. as required. 1005 s/f modular type electronic fan regulator : 1006 supply and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 1007 s/f modular type blanking plate : 1008 supply and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 1009 sub head (ii) : distribution boards & mcbs 1010 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 1011 8 way , double door 1012 supplying and fixing followingway, horizontal type tp&n, sheet steelmcb distribution board,415 v on surface /recess,completewithtinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (but without mcb / rccb / isolators). 1013 8 way (4 + 24), double door 1014 supplying and fixing following rating, double pole, (single phase and neutral), 240 volts,residual current circuit breaker (rccb), having a sensitivity current upto 30 ma in the existingmcbdbcomplete with connections, testing andcommissioning etc. as required. 1015 63 amps. 1016 supplying and fixing 5 amps. to 32 amps. rating, 240 volts `c series,miniature circuit breaker (mcb)suitable for inductive load offollowingpolesin the existingmcbdbcomplete with connections, testing andcommissioning etc. as required. 1017 single pole 1018 supplying & fixing single pole, blanking plate in the existing mcbdbcomplete etc. as required. 1019 supplying and fixing following rating, single/ double/ three pole, 230/ 415 volts, mcb c curve in the existing mcb db complete with connections, testing and commissioning etc. as required. 1020 63 amps fp mcb 1021 40 amps dp mcb 1022 sub head (iii) : telephone, television & data system 1023 s/f modular boxes, base & cover plate : 1024 supplying and fixing following size / modules, gi box along with modular base & cover plate for modular switches inrecessetc as required 1025 1 or 2 module (75 mm x 75 mm) 1026 s/f modular type switch / socket : 1027 supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc as required 1028 telephone socket outlet 1029 tv antenna socket outlet 1030 supply and fixing offollowingsizes of medium class pvc conduit along with accessories in surface/recess including cuttingthe wall and making good the same in case of recessed conduit as required : 1031 20 mm. 1032 25 mm. 1033 supply and drawing followingpair, 0.5 sq.mm. frls pvc insulated annealed copper conductor, unarmoured telephone cable in the existing surface / recessed steel/ pvc conduit as required. 1034 2 pair 1035 supply and drawing co axial tv cable rg 6 grade, 0.7 mm. solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface / recessed steel/ pvc conduit as required. 1036 sub head (iv) : miscellaneous 1037 providing and fixing m.v. dangernotice plate of 200mmx150mm made of mild steel, atleast 2mm thick and vitreous enamelled white on both sides and with inscription singleredcolouronfrlsontsideas required. 1038 supplying and fixing call bell/buzzer suitablefor single phase, 230 volts, complete as required. 1039 providing and fixing circular/ hexagonal cast iron or m.s. sheet box forceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5mm thick m.s. sheet with its top surface hacked for proper bonding,top lid shall be screwed into the cast iron/ m.s. sheet box by means of3.3 mm dia round headed screws, one lock at the corners. clamp shallbe made of 12 mm dia m.s. bar bent to shape as per standard drawing. 1040 sub head(v): internal lighting fixtures & fans 1041 supply of lighting fixtures 1042 supply of 15w surface mounted led with all accessories as per standard item..(such as panasonic adl04r156 or equivalent). 1043 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 1044 supply of 20w surface mounted led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 1045 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 1046 supply of ceiling & exhaust fans 1047 supply of ac230/250 volts, 50 hzceiling fanwith standarddownrod, blades, 2 nos. caps & regulator etc. isi with 5 star marked & energy efficient complete as required. (such as havells velocity/velocity hs or equivalent). 1048 1200 mm sweep 1049 supply of ac230/250 volts, 50 hz exhaust fansincluding providingnuts, bolts, mounting frlsame and other accessories etc. complete as required (such as ventil air dx white or equivalent). 1050 300 mm sweep 900 rpm 1051 erectionoflightingfixturesandfans 1052 installation, testing and commissioning of pre wired, flourescent fitting / compact fluorescent fitting of all types, complete with all accessories and tubes etc. directly on ceiling / wall, including connection with 1.5 sq. mm. frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 1053 installation, testing and commissioning of ceiling fan including wiring the down rod of standard length (upto 30 cm.) with 1.5 sq. mm. frls pvc insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 1054 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required 1055 upto 450 mm sweep 1056 sub head(vi): lightning conductor 1057 providing and fixing of lightning conductor finial, made of 25mm dia 300 mm long, g.i. tube, having single prong at top, with85 mm dia 6 mm thick g.i. base plate including holes etc.complete as required. 1058 jointing copper / g.i. tape (with another copper/ g i tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 1059 fixing of copper/ g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for horizontal run) 1060 fixing of copper/ g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for vertical run) 1061 providing and fixing testing joint, made of 20 mm x 3 mm thickg.i. strip, 125 mm long, with 4 nos. of g.i. bolts, nuts, chucknuts and spring washers etc. complete as required. 1062 laying copper/ g.i. tape 32 mm x 6 mm from earth electrodedirectly in ground as required 1063 earth work 1064 earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1065 all kinds of soil 1066 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 1067 excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 1068 concrete work 1069 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 1070 1:5:10 (1 cement : 5 coarse sand (zone iii) : 10 graded stone aggregate 40 mm nominal size) 1071 providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : 1072 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). 1073 providing and laying damp proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone iii): 4 graded stone aggregate 12.5mm nominal size) 1074 providing & applying a coat of residual petroleum bitumen of grade of vg 10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 1075 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 1076 reinforcedcementconcrete 1077 centering and shuttering including strutting, propping etc. and removal of form for all heights: 1078 foundations, footings, bases of columns, etc. for mass concrete 1079 columns, pillars, piers, abutments, posts and struts 1080 small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like 1081 edges of slabs and breaks in floors and walls 1082 under 20 cms wide 1083 suspended floors, roofs, landings, balconies and access platform. 1084 lintels, beams, plinth beams, girders, bressumers and cantilevers. 1085 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 1086 thermo mechanically treated bars of grade fe 500d or more. 1087 add for plaster drip course/ groove in plastered surface or moulding to r.c.c. projections. 1088 providing and laying in position machine batched and machine mixed design mix m 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per is: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of engineer in charge.“(note : cement content considered in this item is @ 330 kg/cum.“excess/ less cement used as per design mix is payable/recoverable separately). 1089 all works upto plinth level 1090 all works above plinth level upto floor v level 1091 brick work 1092 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in foundation and plinth in: 1093 cement mortar 1:6 (1 cement : 6 coarse sand) 1094 providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick aac blocks in super structure above plinth level up to floor v level with rcc band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of engineer in charge. (the payment of rcc band and reinforcement shall be made for seperately). 1095 half brick masonry with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level. 1096 cement mortar 1:4 (1 cement :4 coarse sand) 1097 extra for providing and placing in position 2 nos 6mm dia. m.s. bars at every third course of half brick masonry. 1098 brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand). 1099 marble work 1100 providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 1101 granite of any colour and shade 1102 area of slab over 0.50 sqm 1103 providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer in charge. 1104 granite work 1105 extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. 1106 extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 1107 wood work & pvc work 1108 providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). 1109 second class teak wood 1110 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 1111 25 mm thick (for cupboard) including isi marked nickel plated bright finished m.s. piano hinges is : 3818 marked with necessary screws 1112 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1113 35 mm thick including isi marked stainless steel butt hinges with necessary screws 1114 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 1115 providing and fixing wire gauge shutters using galvanized m.s. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 1116 35 mm thick shutters 1117 kiln seasoned and chemically treated hollock wood 1118 providing and fixing aluminium sliding door bolts, isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 1119 250x16 mm 1120 providing and fixing aluminium tower bolts, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 1121 200x10 mm 1122 providing and fixing aluminium handles, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 1123 125 mm 1124 providing and fixing aluminium hanging floor door stopper, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. 1125 twin rubber stopper 1126 providing & fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to is : 2046 type s, including cost of adhesive of approved quality. 1127 1.5 mm thick 1128 providing and fixing cup board shutters with 25 mm thick veneered particle board is : 3097 marked, exterior grade (grade i), of approved make, including iind class teak wood lipping of 25 mm wide x 12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of engineer in charge. 1129 with decorative veneering on one side and commercial veneering on other side 1130 providing and fixing factory made upvc white colour sliding glazed window upto 1.50 m in height dimension comprising of upvc multi chambered frame with in built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to upvc profile), appropriate dimension of upvc extruded glazing beads and upvc extruded interlocks, epdm gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), g.i fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of engineer in charge. (single / double glass panes, wire mesh and silicon sealent shall be paid separately). variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 1131 three track three panels sliding window with fly proof s.s wire mesh (two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (area of window above 1.75 sqm). 1132 providing and fixing isi marked oxidised m.s. single acting spring hingeswith necessary screws etc. complete : 1133 150 mm 1134 providing and fixing oxidised m.s. hasp and staple (safety type)conforming to is : 363 with necessary screws etc. complete : 1135 90 mm 1136 providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 1137 75 mm 1138 providing and fixing wooden moulded corner beading of triangular shape to the junction of panelling etc. with iron screws, plugs and priming coat on unexposed surface etc. complete 2nd class teak wood. 1139 50x50 mm (base and height) 1140 float glass panes 1141 4.0 mm thick glass panes (weight not less than 10 kg/sqm). 1142 steel work 1143 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 1144 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1145 providing and fixing t iron frames for doors, windows and ventilators of mild steel tee sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 1146 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1147 providing and fixing circular/ hexagonal cast iron or m.s. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick m.s. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ m.s. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. clamp shall be made of 12 mm dia m.s. bar bent to shape as per standard drawing. 1148 providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 1149 4.0 mm thick glass panes 1150 flooring 1151 kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 1152 25 mm thick. 1153 providing and fixing glass strips in joints of terrazo/ cement concrete floors. 1154 40 mm wide and 4 mm thick 1155 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 1156 extra for pre finished nosing in treads of steps of kota stone/ sand stone slab. 1157 extra for kota stone/ sand stone in treads of steps and risers using single length up to 1.05 metre. 1158 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 1159 providing and laying ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 1160 providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 1161 size of tile 600x600 mm 1162 providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. 1163 size of tile 600x600 mm 1164 roofing 1165 providing and laying brick tiles over mumty roofs, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat. 1166 with common burnt clay f.p.s. (non modular) brick tilesof class designation 10 1167 making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over p.v.c. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 1168 finishing 1169 12 mm cement plaster of mix 1170 1:6 (1 cement: 6 coarse sand) 1171 15 mm cement plaster on rough side of single or half brick wall of mix: 1172 1:6 (1 cement: 6 coarse sand) 1173 white washing with lime to give an even shade : 1174 new work (three or more coats) 1175 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1176 new work (two or more coats) over and including water thinnable priming coat with cement primer 1177 finishing walls with premium acrylic smooth exterior paint withsilicone additives of required shade: 1178 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 1179 applying priming coat: 1180 with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 1181 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 1182 painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 1183 two or more coats on new work 1184 painting with black anti corrosive bitumastic paint of approved brand and manufacture to give an even shade : 1185 two or more coats on new work 1186 water proofing 1187 providing and laying in situ seven course water proofing treatment with app (atactic poly propylene) modified polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to is : 702, 3rd and 5th layers of roofing membrane app modified polymeric membrane 1.5 mm thick of 2.25 kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron hmhdpe film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron hmhdpe film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately). 1188 providing and laying brick tiles over mumty roofs, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat: 12.19.1 with common burnt clay f.p.s. (non modular) brick tilesof class designation 10 1189 earth work 1190 earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1191 all kinds of soil. 1192 excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 1193 all kinds of soil 1194 pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 1195 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 1196 roofing 1197 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 1198 110 mm diameter 1199 providing and fixing on wall face unplasticised pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 1200 coupler 1201 110 mm 1202 bend 87.5° 1203 110 mm bend 1204 shoe (plain) 1205 110 mm shoe 1206 providing and fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with m.s. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 1207 110 mm 1208 providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 1209 sanitary installations 1210 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1211 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 1212 providing and fixing wash basin with c.i. brackets, 15 mm c.p. brass pillar taps, 32 mm c.p. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 1213 white vitreous china flat back wash basin size 550x 400 mm with single 15 mm c.p. brass pillar tap 1214 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is: 13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 1215 kitchen sink with drain board 1216 510x1040 mm bowl depth 250 mm 1217 extra for using coloured pedestal type w.c pan (european type) with low level cistern of same colour instead of white vitreous china w.c pan and cistern. 1218 providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with c.p. brass screws and washers complete. 1219 providing and fixing toilet paper holder : 1220 vitreous china 1221 providing and fixing soil, waste and vent pipes : 1222 100 mm dia. 1223 centrifugally cast (spun) iron socket & spigot (s&s) pipe as per is: 3989 1224 75mm diameter 1225 centrifugally cast (spun) iron socketed pipe as per is: 3989 1226 providing and fixing m.s. holder bat clamps of approved design to sand cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : 1227 for 100 mm dia. pipe 1228 for 75 mm dia. pipe 1229 providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 1230 100 mm 1231 sand cast iron s&s as per is 3989 1232 75 mm 1233 sand cast iron s&s as per is 3989 1234 providing and fixing plain bend of required degree. 1235 100 mm 1236 sand cast iron s&s as per is : 3989 1237 75 mm 1238 sand cast iron s&s as per is 3989 1239 providing and fixing heel rest sanitary bend 1240 100 mmdia 1241 sand cast iron s&s as per is 3989 1242 75 mm dia 1243 sand cast iron s&s as per is 3989 1244 providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3mm thick,bolts and nuts complete. 1245 100x100x100mm 1246 sand cast iron s&s as per is 3989 1247 75x75x75mm 1248 sand cast iron s&s as per is 3989 1249 providing and fixing single equal plain junction of required degree 1250 100x100x100mm 1251 sand cast iron s&s as per is 3989 1252 75x75x75mm 1253 sand cast iron s&s as per is 3989 1254 providing and fixing door piece, insertion rubber washer 3mm thick, bolts & nuts complete : 1255 100 mm 1256 sand cast iron s&s as per is 3989 1257 75 mm 1258 sand cast iron s&s as per is 3989 1259 providing and fixing terminal guard : 1260 100 mm 1261 sand cast iron s&s as per is 3989 1262 75 mm 1263 sand cast iron s&s as per is 3989 1264 providing and fixing collar : 1265 100 mm 1266 sand cast iron s&s as per is 3989 1267 75 mm 1268 sand cast iron s&s as per is 3989 1269 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : 1270 100 mm 1271 75 mm 1272 providing and fixing m.s. stays and clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter : 1273 100 mm 1274 75 mm 1275 providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 1276 100 mm inlet and 100 mm outlet 1277 sand cast iron s&s as per is: 1729 1278 cutting chases in brick masonry walls for following diameter sand cast iron/ centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : 1279 100 mm dia 1280 painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work : 1281 100 mm diameter pipe 1282 75 mm diameter pipe 1283 providing and fixing ptmt waste coupling for wash basin and sink, of approved quality and colour. 1284 waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms 1285 providing and fixing ptmt bottle trap for wash basin and sink. 1286 bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms 1287 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 1288 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour. 1289 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 1290 providing and fixing g.i. pipes complete with g.i. fittings including trenching & refilling. 1291 external work 1292 32mmdia nominal bore 1293 water supply 1294 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 1295 internal work exposed on wall 1296 25 mm nominal outer dia pipes metre 1297 32 mm nominal outer dia pipes metre 1298 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 1299 concealed work, including cutting chases and making good the walls etc. 1300 15 mm nominal outer dia pipes 1301 20 mm nominal outer dia pipes 1302 making connection of g.i. distribution branch with g.i. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 1303 25 to 40 mm nominal bore 1304 providing and fixing brass stop cock of approved quality : 1305 15 mm nominal bore 1306 20 mm nominal bore 1307 providing and fixing gun metal gate valve with c.i. wheel of approved quality (screwed end) : 1308 25mm nominal bore 1309 32mm nominal bore 1310 40mm nominal bore 1311 providing and fixing ball valve (brass) of approved quality, high or low pressure, with plastic floats complete : 1312 25 mm nominal bore 1313 providing and fixing brass ferrule with c.i. mouth cover including boring and tapping the main : 1314 25 mm nominal bore 1315 providing and fixing uplasticised pvc connection pipe with brass unions : 1316 45 cm length 1317 15 mm nominal bore 1318 providing and fixing c.p. brass shower rose with 15 or 20 mm inlet : 1319 100 mm diameter 1320 providing and placing on terrace (at all floor levels) polyethylene water storage tank, is : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 1321 rectangular tank 1322 providing and fixing c.p. brass bib cock of approved quality conforming to is:8931 : 1323 15 mm nominal bore 1324 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 1325 15 mm nominal bore 1326 providing and fixing c.p. brass stop cock (concealed) of standard design and of approved make conforming to is:8931. 1327 15 mm nominal bore. 1328 providing and fixing c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 1329 15 mm nominal bore 1330 providing and fixing ptmt grating of approved quality and colour. 1331 circular type. 1332 100 mm nominal dia. 1333 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 1334 sewarage & drainage 1335 providing and fixing square mouth s.w. gully trap class sp 1 complete with c.i. grating brick masonry chamber with water tight c.i. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70kg as per standard design: 1336 150 x 100 mm size p type 1337 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 1338 making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 1339 for pipes 100 to 250 mm diameter 1340 providing, laying and jointing non pressure np2 class (light duty)rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 1341 150 mm dia rcc pipe 1342 subhead i wiring 1343 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. 1344 group c 1345 wiring for light/ power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 1346 supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 1347 4 module (125 mmx75 mm) 1348 supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1349 15/16 a switch 1350 3 pin 5/6 a socket outlet 1351 telephone socket outlet 1352 tv antenna socket outlet 1353 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 1354 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire 1355 2 x 10 sq. mm + 1 x 6 sq. mm earth wire 1356 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface/ recessed steel/ pvc conduit as required. 1357 supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 1358 1 or 2 module (75 mmx75 mm) 1359 supplying and drawing following pair 0.5 mm dia frls pvc insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ pvc conduit as required. 1360 2 pair 1361 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1362 20 mm 1363 25 mm 1364 providing and fixing in position 2mm thick m.s. telephone junction box of size suitable for fixing of following krone tag block with key lock arrangement. also provide clamps for fixing tag blocks. 1365 10 pair telephone tag blockwith box 1366 supplying, laying of 10 pair unarmoured pvc insulated copper conductor (atc) telephone cable in ground/existing pipes/on wall and making connection with telephone main junction box (mdf) including supports and all accessories as required 1367 10 pair cable unarmoured 1368 subhead ii supply & installation of fittings 1369 supplying of following box type fl. fitting made out of crca sheet finished in antirust treated non yellowing super white stove enamelled paint duly wired with copper wound heavy duty choke starter holder, starter but without lamp complete etc. as reqd. 1370 mounting rail for tled lamps 1600 lumens (tmc 501 p 1xt led with essential led 18w tube) 1371 supplying of wall bracket light fittings suitable for 11 / 13 w cfl lamp. the fitting shall be made up of m.s. powder coated provided with integral ballast, frosted glass and 1 no. 11 / 13 wlamp duly wired upto the connector block complete as required. (decon cat. no.05aam) 1372 supplying of ceiling light fittings suitable for 1 x 15/20 w led lamp. the fitting shall be made up of m.s. powder coated provided with electronic ballast, 1 no. 15/20 w led lamp duly wired upto the connector block etc. complete as required. 1373 cirrus mini pro 15 / 20 watt & 1100 /1600 lumens (philips sm200c led11s 6500 psu od wh) 1374 supplying of bulk head fittings suitable for 10 w led lamp complete with ballast & accessories such as glass, wire guard, 60 w cfl lamp etc. complete as required. 1375 endural led bulkhead, 10 w, 600 lumen such as (philips wt202w led6s cw psu s2 pc) 1376 supplying of exhaustfan, all complete with mounting ring frame i/c bracket,but without regulator with shutters in the following sizes. (g.e. alsthom, khaitan & havells company) 1377 300 mm 4 pole 1378 supplying of 1400 mm sweep a.c. electric ceiling fans, capacitor type with double ball bearing complete with 300 mm down rod, canopies, shackles, blades, but without regulator suitable for operation on 230 / 240 volts, 50 hz, single phase, a.c. supply. (crompton, khaitan & havells company) 1379 supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 1380 installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 1381 installation, testing and commissioning of pre wired, light fixture / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 1382 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 1383 upto 450 mm sweep 1384 extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. 1385 installation, testing and commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two gls/cfl/ led lamps per fitting, complete with all accessories including connections etc. as required. 1386 supplying and fixing call bell/ buzzer suitable for single phase, 230 v, complete as required. 1387 subhead iii distribution board 1388 supplying, installing, testing and commissioning of compartmentalised cubical type meter board for installation of single phase meter. the cubical board shall be made of 2mm thick c.r.c.a sheet, duly phosphatised powder coated complete with connection bus bar and following accessories mounted in it. 1389 meter board 1390 incoming : 1391 40a tp mccb having breaking capacity 25 ka 1 no. 1392 outgoing : 1393 space for single phase energy meter 4 nos. 1394 25 amp dp mcb 4 nos. 1395 supplying, installing, testing & commissioning of single phase electronic energy meter, tested as per electricity boards requirement. 1396 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 1397 12 way, spn 1398 supplying and fixing following rating, double pole, 240 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 1399 40 amps 1400 supplying and fixing following rating, double pole, (single phase and neutral), 240 v, residual current circuit breaker (rccb), having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. asrequired. 1401 25 amps 1402 supplying of xlpe insulated, pvc sheathed 1.1 kv grade aluminium conductor heavy duty armoured cable as per is : 7098 of size : 1403 4 x 16 sq.mm. 1404 providing, laying and fixing following dia rcc pipe np2 class (light duty) in ground complete with rcc collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required for crossing road/walls 1405 100 mm dia 1406 supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 1407 single pole 1408 subhead iv earthing 1409 earthing with g.i. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 1410 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re filling as required. 1411 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 1412 earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1413 all kinds of soil 1414 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 1415 excavating, supplying and filling of local earth (including royalty)by mechanical transport upto a lead of 5km also includingramming and watering of the earth in layers not exceeding 20cm in trenches, plinth, sides of foundation etc. complete. 1416 concrete work 1417 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 1418 1:5:10 (1 cement : 5 coarse sand (zone iii) : 10 graded stone aggregate 40 mm nominal size) 1419 providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : 1420 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). 1421 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 1422 providing and laying damp proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone iii): 4 graded stone aggregate 12.5mm nominal size) 1423 providing & applying a coat of residual petroleum bitumen of grade of vg 10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 1424 reinforcedcementconcrete 1425 centering and shuttering including strutting, propping etc. and removal of form for all heights: 1426 foundations, footings, bases of columns, etc. for mass concrete 1427 columns, pillars, piers, abutments, posts and struts 1428 small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like 1429 edges of slabs and breaks in floors and walls 1430 under 20 cms wide 1431 suspended floors, roofs, landings, balconies and access platform. 1432 lintels, beams, plinth beams, girders, bressumers and cantilevers. 1433 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 1434 thermo mechanically treated bars of grade fe 500d or more. 1435 add for plaster drip course/ groove in plastered surface or moulding to r.c.c. projections. 1436 providing and laying in position machine batched and machine mixed design mix m 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per is: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of engineer in charge.“(note : cement content considered in this item is @ 330 kg/cum.“excess/ less cement used as per design mix is payable/recoverable separately). 1437 all works upto plinth level 1438 all works above plinth level upto floor v level 1439 brick work 1440 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in foundation and plinth in: 1441 cement mortar 1:6 (1 cement : 6 coarse sand) 1442 providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick aac blocks in super structure above plinth level up to floor v level with rcc band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of engineer in charge. (the payment of rcc band and reinforcement shall be made for seperately). 1443 half brick masonry with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level. 1444 cement mortar 1:4 (1 cement :4 coarse sand) 1445 extra for providing and placing in position 2 nos 6mm dia. m.s. bars at every third course of half brick masonry. 1446 brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand). 1447 marble work 1448 providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 1449 granite of any colour and shade 1450 area of slab over 0.50 sqm 1451 providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer in charge. 1452 granite work 1453 extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. 1454 wood work & pvc work 1455 providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). 1456 second class teak wood 1457 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 1458 25 mm thick (for cupboard) including isi marked nickel plated bright finished m.s. piano hinges is : 3818 marked with necessary screws 1459 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1460 35 mm thick including isi marked stainless steel butt hinges with necessary screws 1461 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 1462 providing and fixing wire gauge shutters using galvanized m.s. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 1463 35 mm thick shutters 1464 kiln seasoned and chemically treated hollock wood 1465 providing and fixing aluminium sliding door bolts, isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 1466 250x16 mm 1467 providing and fixing aluminium tower bolts, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 1468 200x10 mm 1469 providing and fixing aluminium handles, isi marked, anodised (anodiccoating not less than grade ac 10 as per is : 1868) transparent or dyedto required colour or shade, with necessary screws etc. complete : 1470 125 mm 1471 providing and fixing aluminium hanging floor door stopper, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. 1472 twin rubber stopper 1473 providing and fixing pre laminated flat pressed 3 layer (medium density)particle board or graded wood particle board is : 3087 marked, with oneside decorative and other side balancing lamination grade i, type iiexterior grade is : 12823 marked, in shelves with screws and fittingswherever required, edges to be painted with polyurethane primer (fittingsto be paid separately). 1474 18 mm thick 1475 providing and fixing factory made upvc white colour sliding glazed window upto 1.50 m in height dimension comprising of upvc multi chambered frame with in built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to upvc profile), appropriate dimension of upvc extruded glazing beads and upvc extruded interlocks, epdm gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), g.i fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of engineer in charge. (single / double glass panes, wire mesh and silicon sealent shall be paid separately). variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 1476 three track three panels sliding window with fly proof s.s wire mesh (two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (area of window above 1.75 sqm). 1477 providing and fixing isi marked oxidised m.s. single acting spring hingeswith necessary screws etc. complete : 1478 150 mm 1479 providing and fixing oxidised m.s. hasp and staple (safety type)conforming to is : 363 with necessary screws etc. complete : 1480 90 mm 1481 providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 1482 75 mm 1483 providing and fixing wooden moulded corner beading of triangular shape to the junction of panelling etc. with iron screws, plugs and priming coat on unexposed surface etc. complete 2nd class teak wood. 1484 50x50 mm (base and height) 1485 float glass panes 1486 4 mm thick glass pane (weight not less than 10kg/sqm). 1487 steel work 1488 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 1489 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1490 providing and fixing t iron frames for doors, windows and ventilators of mild steel tee sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 1491 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1492 providing and fixing circular/ hexagonal cast iron or m.s. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick m.s. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ m.s. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. clamp shall be made of 12 mm dia m.s. bar bent to shape as per standard drawing. 1493 providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. 1494 m.s. tube 1495 providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 1496 4.0 mm thick glass panes 1497 flooring 1498 providing and fixing glass strips in joints of terrazo/ cement concrete floors. 1499 40 mm wide and 4 mm thick 1500 kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 1501 25 mm thick. 1502 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 1503 extra for pre finished nosing in treads of steps of kota stone/ sand stone slab. 1504 extra for kota stone/ sand stone in treads of steps and risers using single length up to 1.05 metre. 1505 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 1506 providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand),jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 1507 size of tile 600x600 mm 1508 providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. 1509 size of tile 400x400 mm 1510 roofing 1511 providing and laying brick tiles over mumty roofs, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat. 1512 with common burnt clay f.p.s. (non modular) brick tilesof class designation 10 1513 making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over p.v.c. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 1514 finishing 1515 12 mm cement plaster of mix 1516 1:6 (1 cement: 6 coarse sand) 1517 15 mm cement plaster on rough side of single or half brick wall of mix: 1518 1:6 (1 cement: 6 coarse sand) 1519 white washing with lime to give an even shade : 1520 new work (three or more coats) 1521 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1522 new work (two or more coats) over and including water thinnable priming coat with cement primer 1523 finishing walls with premium acrylic smooth exterior paint withsilicone additives of required shade: 1524 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 1525 applying priming coat: 1526 with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 1527 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 1528 painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 1529 two or more coats on new work 1530 water proofing 1531 providing and laying in situ seven course water proofing treatment with app (atactic poly propylene) modified polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to is : 702, 3rd and 5th layers of roofing membrane app modified polymeric membrane 1.5 mm thick of 2.25 kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron hmhdpe film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron hmhdpe film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately). 1532 providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of w.c., kitchen and the like consisting of: 1533 ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to is 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. 1534 iind course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. 1535 iiird course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. 1536 ivth course of 400 micron thick pvc sheet. (overlaps at joints of pvc sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/ sqm). 1537 non shedule items 1538 providing and laying cinder filling in sunken floors and other locationswith approved quality cinder including watering and light ramming etc.required for proper compaction/completion of the work complete in all respects as per drawings and as directed by the engineer in charge. 1539 providing and laying 1st quality ceramic glazed anti skid floortiles of size 300x300 mm (thickness to be specified by the manufacturer) conforming to is:15622 in all colours, shades, sizes as approved over 20 mm thick bed of cement mortar 1: 4 (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc complete in all respects as per specifications/drawings and to the entire satisfaction to the architect. 1540 earth work 1541 earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1542 all kinds of soil. 1543 excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 1544 all kinds of soil 1545 pipes, cables etc, not exceeding 80 mm dia. 1546 pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 1547 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 1548 roofing 1549 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 1550 110 mm diameter 1551 providing and fixing on wall face unplasticised pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 1552 coupler 1553 110 mm 1554 bend 87.5° 1555 110 mm bend 1556 shoe (plain) 1557 110 mm shoe 1558 providing and fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with m.s. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 1559 110 mm 1560 providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 1561 sanitary installations 1562 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1563 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 1564 providing and fixing white vitreous china pedestal type water closet (european type w.c. pan) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. 1565 w.c. pan with isi marked white solid plastic seat and lid 1566 providing and fixing wash basin with c.i. brackets, 15 mm c.p. brass pillar taps, 32 mm c.p. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 1567 white vitreous china flat back wash basin size 550x 400 mm with single 15 mm c.p. brass pillar tap 1568 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is: 13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 1569 kitchen sink with drain board 1570 510x1040 mm bowl depth 250 mm 1571 extra for using coloured pedestal type w.c pan (european type) with low level cistern of same colour instead of white vitreous china w.c pan and cistern. 1572 providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with c.p. brass screws and washers complete. 1573 providing and fixing toilet paper holder : 1574 vitreous china 1575 providing and fixing soil, waste and vent pipes : 1576 100 mm dia. 1577 centrifugally cast (spun) iron socket & spigot (s&s) pipe as per is: 3989 1578 75mm diameter 1579 centrifugally cast (spun) iron socketed pipe as per is: 3989 1580 providing and fixing m.s. holder bat clamps of approved design to sand cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : 1581 for 100 mm dia. pipe 1582 for 75 mm dia. pipe 1583 providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 1584 100 mm 1585 sand cast iron s&s as per is 3989 1586 75 mm 1587 sand cast iron s&s as per is 3989 1588 providing and fixing plain bend of required degree. 1589 100 mm 1590 sand cast iron s&s as per is : 3989 1591 75 mm 1592 sand cast iron s&s as per is 3989 1593 providing and fixing heel rest sanitary bend 1594 100 mmdia 1595 sand cast iron s&s as per is 3989 1596 75 mm dia 1597 sand cast iron s&s as per is 3989 1598 providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3mm thick,bolts and nuts complete. 1599 100x100x100mm 1600 sand cast iron s&s as per is 3989 1601 75x75x75mm 1602 sand cast iron s&s as per is 3989 1603 providing and fixing single equal plain junction of required degree 1604 100x100x100mm 1605 sand cast iron s&s as per is 3989 1606 75x75x75mm 1607 sand cast iron s&s as per is 3989 1608 providing and fixing door piece, insertion rubber washer 3mm thick, bolts & nuts complete : 1609 100 mm 1610 sand cast iron s&s as per is 3989 1611 75 mm 1612 sand cast iron s&s as per is 3989 1613 providing and fixing terminal guard : 1614 100 mm 1615 sand cast iron s&s as per is 3989 1616 75 mm 1617 sand cast iron s&s as per is 3989 1618 providing and fixing collar : 1619 100 mm 1620 sand cast iron s&s as per is 3989 1621 75 mm 1622 sand cast iron s&s as per is 3989 1623 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : 1624 100 mm 1625 75 mm 1626 providing and fixing m.s. stays and clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter : 1627 100 mm 1628 75 mm 1629 providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 1630 100 mm inlet and 100 mm outlet 1631 sand cast iron s&s as per is: 1729 1632 cutting chases in brick masonry walls for following diameter sand cast iron/ centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : 1633 100 mm dia 1634 painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work : 1635 100 mm diameter pipe 1636 75 mm diameter pipe 1637 providing and fixing ptmt waste coupling for wash basin and sink, of approved quality and colour. 1638 waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms 1639 providing and fixing ptmt bottle trap for wash basin and sink. 1640 bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms 1641 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 1642 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour. 1643 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 1644 providing and fixing g.i. pipes complete with g.i. fittings including trenching & refilling. 1645 external work 1646 32mmdia nominal bore 1647 40mmdia nominal bore 1648 50mmdia nominal bore 1649 water supply 1650 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 1651 internal work exposed on wall 1652 25 mm nominal outer dia pipes metre 1653 32 mm nominal outer dia pipes metre 1654 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 1655 concealed work, including cutting chases and making good the walls etc. 1656 15 mm nominal outer dia pipes 1657 20 mm nominal outer dia pipes 1658 making connection of g.i. distribution branch with g.i. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 1659 25 to 40 mm nominal bore 1660 providing and fixing brass stop cock of approved quality : 1661 15 mm nominal bore 1662 20 mm nominal bore 1663 providing and fixing gun metal gate valve with c.i. wheel of approved quality (screwed end) : 1664 25mm nominal bore 1665 32mm nominal bore 1666 40mm nominal bore 1667 providing and fixing ball valve (brass) of approved quality, high or low pressure, with plastic floats complete : 1668 25 mm nominal bore 1669 providing and fixing brass ferrule with c.i. mouth cover including boring and tapping the main : 1670 25 mm nominal bore 1671 providing and fixing uplasticised pvc connection pipe with brass unions : 1672 45 cm length 1673 15 mm nominal bore 1674 providing and fixing c.p. brass shower rose with 15 or 20 mm inlet : 1675 100 mm diameter 1676 providing and placing on terrace (at all floor levels) polyethylene water storage tank, is : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 1677 rectangular tank 1678 providing and fixing c.p. brass bib cock of approved quality conforming to is:8931 : 1679 15 mm nominal bore 1680 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 1681 15 mm nominal bore 1682 providing and fixing c.p. brass stop cock (concealed) of standard design and of approved make conforming to is:8931. 1683 15 mm nominal bore. 1684 providing and fixing c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 1685 15 mm nominal bore 1686 providing and fixing ptmt grating of approved quality and colour. 1687 circular type. 1688 100 mm nominal dia. 1689 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 1690 sewarage & drainage 1691 providing, laying and jointing glazed stoneware pipes class sp 1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 1692 100 mm diameter 1693 150 mm diameter 1694 providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all round s.w. pipes including bed concrete as per standard design : 1695 100 mm diameter s.w. pipe 1696 150 mm diameter s.w. pipe 1697 providing and fixing square mouth s.w. gully trap class sp 1 complete with c.i. grating brick masonry chamber with water tight c.i. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70kg as per standard design: 1698 150 x 100 mm size p type 1699 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 1700 providing, laying and jointing non pressure np2 class (light duty)rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 1701 150 mm dia rcc pipe 1702 subhead i wiring 1703 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. 1704 group c 1705 wiring for light/ power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 1706 supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 1707 4 module (125 mmx75 mm) 1708 supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1709 15/16 a switch 1710 3 pin 5/6 a socket outlet 1711 telephone socket outlet 1712 tv antenna socket outlet 1713 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 1714 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire 1715 2 x 10 sq. mm + 1 x 6 sq. mm earth wire 1716 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface/ recessed steel/ pvc conduit as required. 1717 supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 1718 25 mm 1719 supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 1720 1 or 2 module (75 mmx75 mm) 1721 supplying and drawing following pair 0.5 mm dia frls pvc insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ pvc conduit as required. 1722 2 pair 1723 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1724 20 mm 1725 25 mm 1726 providing and fixing in position 2mm thick m.s. telephone junction box of size suitable for fixing of following krone tag block with key lock arrangement. also provide clamps for fixing tag blocks. 1727 10 pair telephone tag blockwith box 1728 supplying, laying of 10 pair unarmoured pvc insulated copper conductor (atc) telephone cable in ground/existing pipes/on wall and making connection with telephone main junction box (mdf) including supports and all accessories as required 1729 10 pair cable unarmoured 1730 subhead ii supply & installation of fittings 1731 supplying of following box type fl. fitting made out of crca sheet finished in antirust treated non yellowing super white stove enamelled paint duly wired with copper wound heavy duty choke starter holder, starter but without lamp complete etc. as reqd. 1732 mounting rail for tled lamps 1600 lumens (tmc 501 p 1xt led with essential led 18w tube) 1733 supplying of wall bracket light fittings suitable for 11 / 13 w cfl lamp. the fitting shall be made up of m.s. powder coated provided with integral ballast, frosted glass and 1 no. 11 / 13 wlamp duly wired upto the connector block complete as required. (decon cat. no.05aam) 1734 supplying of ceiling light fittings suitable for 1 x 15/20 w led lamp. the fitting shall be made up of m.s. powder coated provided with electronic ballast, 1 no. 15/20 w led lamp duly wired upto the connector block etc. complete as required. 1735 cirrus mini pro 15 / 20 watt & 1100 /1600 lumens (philips sm200c led11s 6500 psu od wh) 1736 supplying of bulk head fittings suitable for 10 w led lamp complete with ballast & accessories such as glass, wire guard, 60 w cfl lamp etc. complete as required. 1737 endural led bulkhead, 10 w, 600 lumen such as (philips wt202w led6s cw psu s2 pc) 1738 supplying of exhaustfan, all complete with mounting ring frame i/c bracket,but without regulator with shutters in the following sizes. (g.e. alsthom, khaitan & havells company) 1739 300 mm 4 pole 1740 supplying of 1400 mm sweep a.c. electric ceiling fans, capacitor type with double ball bearing complete with 300 mm down rod, canopies, shackles, blades, but without regulator suitable for operation on 230 / 240 volts, 50 hz, single phase, a.c. supply. (crompton, khaitan & havells company) 1741 supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 1742 installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 1743 installation, testing and commissioning of pre wired, light fixture / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 1744 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 1745 upto 450 mm sweep 1746 extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. 1747 installation, testing and commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two gls/cfl/ led lamps per fitting, complete with all accessories including connections etc. as required. 1748 supplying and fixing call bell/ buzzer suitable for single phase, 230 v, complete as required. 1749 subhead iii distribution board 1750 supplying, installing, testing and commissioning of compartmentalised cubical type meter board for installation of single phase meter. the cubical board shall be made of 2mm thick c.r.c.a sheet, duly phosphatised powder coated complete with connection bus bar and following accessories mounted in it. 1751 meter board 1752 incoming : 1753 40a tp mccb having breaking capacity 25 ka 1 no. 1754 outgoing : 1755 space for single phase energy meter 4 nos. 1756 25 amp dp mcb 4 nos. 1757 supplying, installing, testing & commissioning of single phase electronic energy meter, tested as per electricity boards requirement. 1758 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 1759 12 way, spn 1760 supplying and fixing following rating, double pole, 240 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 1761 40 amps 1762 supplying and fixing following rating, double pole, (single phase and neutral), 240 v, residual current circuit breaker (rccb), having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. asrequired. 1763 25 amps 1764 supplying of xlpe insulated, pvc sheathed 1.1 kv grade aluminium conductor heavy duty armoured cable as per is : 7098 of size : 1765 4 x 16 sq.mm. 1766 providing, laying and fixing following dia rcc pipe np2 class (light duty) in ground complete with rcc collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required for crossing road/walls 1767 100 mm dia 1768 supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 1769 single pole 1770 subhead iv earthing 1771 earthing with g.i. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 1772 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re filling as required. 1773 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 1774 subhead v lightning conductor 1775 providing and fixing of lightning conductor finial, made of 25mm dia 300 mm long, g.i. tube, having single prong at top, with85 mm dia 6 mm thick g.i. base plate including holes etc.complete as required. 1776 jointing copper / g.i. tape (with another copper/ g i tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 1777 fixing of copper/ g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for horizontal run) 1778 fixing of copper/ g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for vertical run) 1779 providing and fixing testing joint, made of 20 mm x 3 mm thickg.i. strip, 125 mm long, with 4 nos. of g.i. bolts, nuts, chucknuts and spring washers etc. complete as required. 1780 laying copper/ g.i. tape 32 mm x 6 mm from earth electrodedirectly in ground as required 1781 earth work 1782 earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1783 all kinds of soil 1784 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 1785 excavating, supplying and filling of local earth (including royalty)by mechanical transport upto a lead of 5km also includingramming and watering of the earth in layers not exceeding 20cm in trenches, plinth, sides of foundation etc. complete. 1786 concrete work 1787 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 1788 1:5:10 (1 cement : 5 coarse sand (zone iii) : 10 graded stone aggregate 40 mm nominal size) 1789 providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : 1790 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). 1791 providing and laying damp proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone iii): 4 graded stone aggregate 12.5mm nominal size) 1792 providing & applying a coat of residual petroleum bitumen of grade of vg 10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 1793 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 1794 reinforcedcementconcrete 1795 centering and shuttering including strutting, propping etc. and removal of form for all heights: 1796 foundations, footings, bases of columns, etc. for mass concrete 1797 walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc 1798 columns, pillars, piers, abutments, posts and struts 1799 small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like 1800 edges of slabs and breaks in floors and walls 1801 under 20 cms wide 1802 suspended floors, roofs, landings, balconies and access platform. 1803 lintels, beams, plinth beams, girders, bressumers and cantilevers. 1804 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 1805 thermo mechanically treated bars of grade fe 500d or more. 1806 add for plaster drip course/ groove in plastered surface or moulding to r.c.c. projections. 1807 providing and laying in position machine batched and machine mixed design mix m 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per is: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of engineer in charge.“(note : cement content considered in this item is @ 330 kg/cum.“excess/ less cement used as per design mix is payable/recoverable separately). 1808 all works upto plinth level 1809 all works above plinth level upto floor v level 1810 brick work 1811 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in foundation and plinth in: 1812 cement mortar 1:6 (1 cement : 6 coarse sand) 1813 providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick aac blocks in super structure above plinth level up to floor v level with rcc band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of engineer in charge. (the payment of rcc band and reinforcement shall be made for seperately). 1814 half brick masonry with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level. 1815 cement mortar 1:4 (1 cement :4 coarse sand) 1816 extra for providing and placing in position 2 nos 6mm dia. m.s. bars at every third course of half brick masonry. 1817 brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand). 1818 marble work 1819 providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 1820 granite of any colour and shade 1821 area of slab over 0.50 sqm 1822 providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer in charge. 1823 granite work 1824 extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. 1825 wood work & pvc work 1826 providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). 1827 second class teak wood 1828 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 1829 25 mm thick (for cupboard) including isi marked nickel plated bright finished m.s. piano hinges is : 3818 marked with necessary screws 1830 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1831 35 mm thick including isi marked stainless steel butt hinges with necessary screws 1832 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 1833 providing and fixing wire gauge shutters using galvanized m.s. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 1834 35 mm thick shutters 1835 kiln seasoned and chemically treated hollock wood 1836 providing and fixing aluminium sliding door bolts, isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 1837 250x16 mm 1838 providing and fixing aluminium tower bolts, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 1839 200x10 mm 1840 providing and fixing aluminium handles, isi marked, anodised (anodiccoating not less than grade ac 10 as per is : 1868) transparent or dyedto required colour or shade, with necessary screws etc. complete : 1841 125 mm 1842 providing and fixing aluminium hanging floor door stopper, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. 1843 twin rubber stopper 1844 providing and fixing pre laminated flat pressed 3 layer (medium density)particle board or graded wood particle board is : 3087 marked, with oneside decorative and other side balancing lamination grade i, type iiexterior grade is : 12823 marked, in shelves with screws and fittingswherever required, edges to be painted with polyurethane primer (fittingsto be paid separately). 1845 18 mm thick 1846 providing and fixing factory made upvc white colour sliding glazed window upto 1.50 m in height dimension comprising of upvc multi chambered frame with in built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to upvc profile), appropriate dimension of upvc extruded glazing beads and upvc extruded interlocks, epdm gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), g.i fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of engineer in charge. (single / double glass panes, wire mesh and silicon sealent shall be paid separately). variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 1847 three track three panels sliding window with fly proof s.s wire mesh (two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (area of window above 1.75 sqm). 1848 providing and fixing isi marked oxidised m.s. single acting spring hingeswith necessary screws etc. complete : 1849 150 mm 1850 providing and fixing oxidised m.s. hasp and staple (safety type)conforming to is : 363 with necessary screws etc. complete : 1851 90 mm 1852 providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 1853 75 mm 1854 providing and fixing wooden moulded corner beading of triangular shape to the junction of panelling etc. with iron screws, plugs and priming coat on unexposed surface etc. complete 2nd class teak wood. 1855 50x50 mm (base and height) 1856 float glass panes 1857 4 mm thick glass pane (weight not less than 10kg/sqm). 1858 steel work 1859 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 1860 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1861 providing and fixing t iron frames for doors, windows and ventilators of mild steel tee sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 1862 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1863 providing and fixing circular/ hexagonal cast iron or m.s. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick m.s. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ m.s. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. clamp shall be made of 12 mm dia m.s. bar bent to shape as per standard drawing. 1864 providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. 1865 m.s. tube 1866 providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 1867 4.0 mm thick glass panes 1868 flooring 1869 providing and fixing glass strips in joints of terrazo/ cement concrete floors. 1870 40 mm wide and 4 mm thick 1871 kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 1872 25 mm thick. 1873 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 1874 extra for pre finished nosing in treads of steps of kota stone/ sand stone slab. 1875 extra for kota stone/ sand stone in treads of steps and risers using single length up to 1.05 metre. 1876 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 1877 providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand),jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 1878 size of tile 600x600 mm 1879 providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. 1880 size of tile 400x400 mm 1881 roofing 1882 providing and laying brick tiles over mumty roofs, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat. 1883 with common burnt clay f.p.s. (non modular) brick tilesof class designation 10 1884 making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over p.v.c. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 1885 finishing 1886 12 mm cement plaster of mix 1887 1:6 (1 cement: 6 coarse sand) 1888 15 mm cement plaster on rough side of single or half brick wall of mix: 1889 1:6 (1 cement: 6 coarse sand) 1890 white washing with lime to give an even shade : 1891 new work (three or more coats) 1892 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1893 new work (two or more coats) over and including water thinnable priming coat with cement primer 1894 finishing walls with premium acrylic smooth exterior paint withsilicone additives of required shade: 1895 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 1896 applying priming coat: 1897 with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 1898 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 1899 painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 1900 two or more coats on new work 1901 water proofing 1902 providing and laying in situ seven course water proofing treatment with app (atactic poly propylene) modified polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to is : 702, 3rd and 5th layers of roofing membrane app modified polymeric membrane 1.5 mm thick of 2.25 kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron hmhdpe film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron hmhdpe film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately). 1903 applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to is. 2645 and approved by engineer in charge over the rcc slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. 1904 laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to is : 2645 and approved by engineerin charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to is : 2645 and approved by engineerin charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. 1905 after two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to is : 2645 and approved by engineer in charge. 1906 finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to is : 2645 and approved by engineer in charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. 1907 the whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“all above operations to be done in order and as directed and specified by the engineer in charge : 1908 the 1909 providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of w.c., kitchen and the like consisting of: 1910 ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to is 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. 1911 iind course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. 1912 iiird course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. 1913 ivth course of 400 micron thick pvc sheet. (overlaps at joints of pvc sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/ sqm). 1914 non shedule items 1915 providing and laying cinder filling in sunken floors and other locationswith approved quality cinder including watering and light ramming etc.required for proper compaction/completion of the work complete in all respects as per drawings and as directed by the engineer in charge. 1916 providing and laying 1st quality ceramic glazed anti skid floortiles of size 300x300 mm (thickness to be specified by the manufacturer) conforming to is:15622 in all colours, shades, sizes as approved over 20 mm thick bed of cement mortar 1: 4 (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc complete in all respects as per specifications/drawings and to the entire satisfaction to the architect. 1917 earth work 1918 earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1919 all kinds of soil. 1920 excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 1921 all kinds of soil 1922 pipes, cables etc, not exceeding 80 mm dia. 1923 pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 1924 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 1925 roofing 1926 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 1927 110 mm diameter 1928 providing and fixing on wall face unplasticised pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 1929 coupler 1930 110 mm 1931 bend 87.5° 1932 110 mm bend 1933 shoe (plain) 1934 110 mm shoe 1935 providing and fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with m.s. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 1936 110 mm 1937 providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 1938 sanitary installations 1939 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1940 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 1941 providing and fixing white vitreous china pedestal type water closet (european type w.c. pan) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. 1942 w.c. pan with isi marked white solid plastic seat and lid 1943 providing and fixing wash basin with c.i. brackets, 15 mm c.p. brass pillar taps, 32 mm c.p. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 1944 white vitreous china flat back wash basin size 550x 400 mm with single 15 mm c.p. brass pillar tap 1945 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is: 13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 1946 kitchen sink with drain board 1947 510x1040 mm bowl depth 250 mm 1948 extra for using coloured pedestal type w.c pan (european type) with low level cistern of same colour instead of white vitreous china w.c pan and cistern. 1949 providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with c.p. brass screws and washers complete. 1950 providing and fixing toilet paper holder : 1951 vitreous china 1952 providing and fixing soil, waste and vent pipes : 1953 100 mm dia. 1954 centrifugally cast (spun) iron socket & spigot (s&s) pipe as per is: 3989 1955 75mm diameter 1956 centrifugally cast (spun) iron socketed pipe as per is: 3989 1957 providing and fixing m.s. holder bat clamps of approved design to sand cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : 1958 for 100 mm dia. pipe 1959 for 75 mm dia. pipe 1960 providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 1961 100 mm 1962 sand cast iron s&s as per is 3989 1963 75 mm 1964 sand cast iron s&s as per is 3989 1965 providing and fixing plain bend of required degree. 1966 100 mm 1967 sand cast iron s&s as per is : 3989 1968 75 mm 1969 sand cast iron s&s as per is 3989 1970 providing and fixing heel rest sanitary bend 1971 100 mmdia 1972 sand cast iron s&s as per is 3989 1973 75 mm dia 1974 sand cast iron s&s as per is 3989 1975 providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3mm thick,bolts and nuts complete. 1976 100x100x100mm 1977 sand cast iron s&s as per is 3989 1978 75x75x75mm 1979 sand cast iron s&s as per is 3989 1980 providing and fixing single equal plain junction of required degree 1981 100x100x100mm 1982 sand cast iron s&s as per is 3989 1983 75x75x75mm 1984 sand cast iron s&s as per is 3989 1985 providing and fixing door piece, insertion rubber washer 3mm thick, bolts & nuts complete : 1986 100 mm 1987 sand cast iron s&s as per is 3989 1988 75 mm 1989 sand cast iron s&s as per is 3989 1990 providing and fixing terminal guard : 1991 100 mm 1992 sand cast iron s&s as per is 3989 1993 75 mm 1994 sand cast iron s&s as per is 3989 1995 providing and fixing collar : 1996 100 mm 1997 sand cast iron s&s as per is 3989 1998 75 mm 1999 sand cast iron s&s as per is 3989 2000 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : 2001 100 mm 2002 75 mm 2003 providing and fixing m.s. stays and clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter : 2004 100 mm 2005 75 mm 2006 providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 2007 100 mm inlet and 100 mm outlet 2008 sand cast iron s&s as per is: 1729 2009 cutting chases in brick masonry walls for following diameter sand cast iron/ centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : 2010 100 mm dia 2011 painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work : 2012 100 mm diameter pipe 2013 75 mm diameter pipe 2014 providing and fixing ptmt waste coupling for wash basin and sink, of approved quality and colour. 2015 waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms 2016 providing and fixing ptmt bottle trap for wash basin and sink. 2017 bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms 2018 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 2019 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour. 2020 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 2021 providing and fixing g.i. pipes complete with g.i. fittings including trenching & refilling. 2022 external work 2023 32mmdia nominal bore 2024 40mmdia nominal bore 2025 50mmdia nominal bore 2026 water supply 2027 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 2028 internal work exposed on wall 2029 25 mm nominal outer dia pipes metre 2030 32 mm nominal outer dia pipes metre 2031 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 2032 concealed work, including cutting chases and making good the walls etc. 2033 15 mm nominal outer dia pipes 2034 20 mm nominal outer dia pipes 2035 making connection of g.i. distribution branch with g.i. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 2036 25 to 40 mm nominal bore 2037 providing and fixing brass stop cock of approved quality : 2038 15 mm nominal bore 2039 20 mm nominal bore 2040 providing and fixing gun metal gate valve with c.i. wheel of approved quality (screwed end) : 2041 25mm nominal bore 2042 32mm nominal bore 2043 40mm nominal bore 2044 providing and fixing ball valve (brass) of approved quality, high or low pressure, with plastic floats complete : 2045 25 mm nominal bore 2046 providing and fixing brass ferrule with c.i. mouth cover including boring and tapping the main : 2047 25 mm nominal bore 2048 providing and fixing uplasticised pvc connection pipe with brass unions : 2049 45 cm length 2050 15 mm nominal bore 2051 providing and fixing c.p. brass shower rose with 15 or 20 mm inlet : 2052 100 mm diameter 2053 providing and placing on terrace (at all floor levels) polyethylene water storage tank, is : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 2054 rectangular tank 2055 providing and fixing c.p. brass bib cock of approved quality conforming to is:8931 : 2056 15 mm nominal bore 2057 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 2058 15 mm nominal bore 2059 providing and fixing c.p. brass stop cock (concealed) of standard design and of approved make conforming to is:8931. 2060 15 mm nominal bore. 2061 providing and fixing c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 2062 15 mm nominal bore 2063 providing and fixing ptmt grating of approved quality and colour. 2064 circular type. 2065 100 mm nominal dia. 2066 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 2067 sewarage & drainage 2068 providing, laying and jointing glazed stoneware pipes class sp 1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 2069 100 mm diameter 2070 150 mm diameter 2071 providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all round s.w. pipes including bed concrete as per standard design : 2072 100 mm diameter s.w. pipe 2073 150 mm diameter s.w. pipe 2074 providing and fixing square mouth s.w. gully trap class sp 1 complete with c.i. grating brick masonry chamber with water tight c.i. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70kg as per standard design: 2075 150 x 100 mm size p type 2076 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 2077 providing, laying and jointing non pressure np2 class (light duty)rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 2078 150 mm dia rcc pipe 2079 subhead i wiring 2080 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. 2081 group c 2082 wiring for light/ power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 2083 supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 2084 4 module (125 mmx75 mm) 2085 supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 2086 15/16 a switch 2087 3 pin 5/6 a socket outlet 2088 telephone socket outlet 2089 tv antenna socket outlet 2090 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2091 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire 2092 2 x 10 sq. mm + 1 x 6 sq. mm earth wire 2093 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface/ recessed steel/ pvc conduit as required. 2094 supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 2095 25 mm 2096 supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 2097 1 or 2 module (75 mmx75 mm) 2098 supplying and drawing following pair 0.5 mm dia frls pvc insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ pvc conduit as required. 2099 2 pair 2100 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 2101 20 mm 2102 25 mm 2103 providing and fixing in position 2mm thick m.s. telephone junction box of size suitable for fixing of following krone tag block with key lock arrangement. also provide clamps for fixing tag blocks. 2104 10 pair telephone tag blockwith box 2105 supplying, laying of 10 pair unarmoured pvc insulated copper conductor (atc) telephone cable in ground/existing pipes/on wall and making connection with telephone main junction box (mdf) including supports and all accessories as required 2106 10 pair cable unarmoured 2107 subhead ii supply & installation of fittings 2108 supplying of following box type fl. fitting made out of crca sheet finished in antirust treated non yellowing super white stove enamelled paint duly wired with copper wound heavy duty choke starter holder, starter but without lamp complete etc. as reqd. 2109 mounting rail for tled lamps 1600 lumens (tmc 501 p 1xt led with essential led 18w tube) 2110 supplying of wall bracket light fittings suitable for 11 / 13 w cfl lamp. the fitting shall be made up of m.s. powder coated provided with integral ballast, frosted glass and 1 no. 11 / 13 wlamp duly wired upto the connector block complete as required. (decon cat. no.05aam) 2111 supplying of ceiling light fittings suitable for 1 x 15/20 w led lamp. the fitting shall be made up of m.s. powder coated provided with electronic ballast, 1 no. 15/20 w led lamp duly wired upto the connector block etc. complete as required. 2112 cirrus mini pro 15 / 20 watt & 1100 /1600 lumens (philips sm200c led11s 6500 psu od wh) 2113 supplying of bulk head fittings suitable for 10 w led lamp complete with ballast & accessories such as glass, wire guard, 60 w cfl lamp etc. complete as required. 2114 endural led bulkhead, 10 w, 600 lumen such as (philips wt202w led6s cw psu s2 pc) 2115 supplying of exhaustfan, all complete with mounting ring frame i/c bracket,but without regulator with shutters in the following sizes. (g.e. alsthom, khaitan & havells company) 2116 300 mm 4 pole 2117 supplying of 1400 mm sweep a.c. electric ceiling fans, capacitor type with double ball bearing complete with 300 mm down rod, canopies, shackles, blades, but without regulator suitable for operation on 230 / 240 volts, 50 hz, single phase, a.c. supply. (crompton, khaitan & havells company) 2118 supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 2119 installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 2120 installation, testing and commissioning of pre wired, light fixture / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 2121 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 2122 upto 450 mm sweep 2123 extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. 2124 installation, testing and commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two gls/cfl/ led lamps per fitting, complete with all accessories including connections etc. as required. 2125 supplying and fixing call bell/ buzzer suitable for single phase, 230 v, complete as required. 2126 subhead iii distribution board 2127 supplying, installing, testing and commissioning of compartmentalised cubical type meter board for installation of single phase meter. the cubical board shall be made of 2mm thick c.r.c.a sheet, duly phosphatised powder coated complete with connection bus bar and following accessories mounted in it. 2128 meter board 2129 incoming : 2130 40a tp mccb having breaking capacity 25 ka 1 no. 2131 outgoing : 2132 space for single phase energy meter 4 nos. 2133 25 amp dp mcb 4 nos. 2134 supplying, installing, testing & commissioning of single phase electronic energy meter, tested as per electricity boards requirement. 2135 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 2136 12 way, spn 2137 supplying and fixing following rating, double pole, 240 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 2138 40 amps 2139 supplying and fixing following rating, double pole, (single phase and neutral), 240 v, residual current circuit breaker (rccb), having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. asrequired. 2140 25 amps 2141 supplying of xlpe insulated, pvc sheathed 1.1 kv grade aluminium conductor heavy duty armoured cable as per is : 7098 of size : 2142 4 x 16 sq.mm. 2143 providing, laying and fixing following dia rcc pipe np2 class (light duty) in ground complete with rcc collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required for crossing road/walls 2144 100 mm dia 2145 supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 2146 single pole 2147 subhead iv earthing 2148 earthing with g.i. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 2149 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re filling as required. 2150 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 2151 subhead v lightning conductor 2152 providing and fixing of lightning conductor finial, made of 25mm dia 300 mm long, g.i. tube, having single prong at top, with85 mm dia 6 mm thick g.i. base plate including holes etc.complete as required. 2153 jointing copper / g.i. tape (with another copper/ g i tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 2154 fixing of copper/ g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for horizontal run) 2155 fixing of copper/ g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for vertical run) 2156 providing and fixing testing joint, made of 20 mm x 3 mm thickg.i. strip, 125 mm long, with 4 nos. of g.i. bolts, nuts, chucknuts and spring washers etc. complete as required. 2157 laying copper/ g.i. tape 32 mm x 6 mm from earth electrodedirectly in ground as required 2158 levelling 2159 0.75 boys dormitory 2160 0.25 girls dormitory 2161 guest house 2162 type 3(g+2) 2163 type 3(g+1) 2164 type 4(g) 2165 type 2(g+2) 2166 earth work in excavation by mechanical means (hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. 2167 all kinds of soil 2168 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 2169 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. all work upto plinth level. 2170 1:5:10 (1 cement : 5 coarse sand (zone iii): 10 graded stone aggregate 40 mm nominal size). 2171 c/s for mass concrete 2172 providing and laying 60mm thick faciory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved s;ze, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of engineer in charge. 2173 providing and laying at or near ground level factory made kerb stone of m 25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of engineer in charge (length of finished kerb edging shall be measured for payment). (precast c.c. kerb stone shall be approved by engineer in charge). 2174 excavating trenches upto 1.5 meter depth in all kind ofsoil of required width for pipes. including excavation for sockets and dressing of sides ramming of bottoms including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m or as directed at site by engg in charge. 2175 all kinds of soil 2176 pipes, cables etc, not exceeding 80 mm dia. 2177 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings. this includes jointing of pipes & fittings with one step cpvc solvent cement, trenching, refilling & testing of joints complete as per direction of engineer in charge : external work 2178 external work 2179 25 mm dia nominal bore 2180 for vertical 2181 type 2(g+2) (3x3+5) = 14 meter 2182 type 3(g+2) (3x3+5) = 14 meter 2183 type 3(g+1) (3x2+5) = 11 meter 2184 type iv (3+5) = 8 meter 2185 type guest house (3+5) = 8 meter 2186 32 mm dia nominal bore for horizontal surface 2187 for vertical 2188 boys dormitory (3x3+5)=14 meter 2189 girls dormitory (3x2+5)=11 meter 2190 providing and fixing gun metal non return valve of approved quality (screwed end) : 2191 32 mm nominal bore 2192 horizontal 2193 construction of masonary chamber60x60x75 inside in brickwork cement mortar 1.6 2194 with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 2195 providing and fixing c.i. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (the tail pieces, tapers etc if required will be paid separately) : 2196 50 mm dia 2197 providing and fixing gun metal gate valve with c.i. wheel of approved quality (screwed end) : 2198 25 mm nominal bore 2199 32 mm nominal bore 2200 providing and laying in position cement concreteof specified grade excluding the cost of centering and shuttering (for thrust blocks at bends and junctions of water lines )by 1:2:4 (1 cement : 2 coarse sand : 4 graded stone agg. 20 mm nominal size) 2201 providing and fixing g.i. union in gi pipe including cutting and threading the pipe and making long screws etc. complete(new work) 2202 25 mm nominal bore 2203 32 mm nominal bore 2204 40 mm nominal bore 2205 providing and fixing in position pre cast r.c.c. manhole cover and frame of required shape and approved quality 2206 ld 2.5 2207 rectangular shape 600*450 mm internal dimensions 2208 earth work in excavation by mechanical means (hydraulic excavator) i manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2209 all kinds of soil.0.00 1.50m 2210 extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. 2211 all kinds of soil 2212 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 2213 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 2214 1:5:10 (1 cement : 5 coarse sand (zone iii): 10 graded stone aggregate 40 mm nominal size). 2215 providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement all work up to plinth level: 2216 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) 2217 centering and shuttering including strutting, propping etc. and removal of form for: 2218 foundations, footings, bases of columns, etc. for mass concrete. 2219 walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 2220 suspended floors, roofs, landings, balconies and access platform. 2221 lintels, beams, plinth beams, girders, bressumers and cantilevers. 2222 edges of slabs and breaks in floors and walls. 2223 under 20 cm wide 2224 reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete. 2225 thermo mechanically treated bars. 2226 cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete 2227 40 mm thick with 20 mm nominal size stone aggregate 2228 6 mm cement plaster of mix : 2229 1:3 (1 cement : 3 fine sand) 2230 providing and fixing in position pre cast r.c.c. manhole cover and frame of required shape and approved quality 2231 square shape 450 mm internal dimension 2232 providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per is : 10910 on 12mm dia steel bar conforming to is : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 2233 providing and fixing soil, waste and vent pipes 2234 100 mm dia. 2235 centrifugally cast (spun) iron socketed pipe as per is: 3989. 2236 making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and s.w. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. 2237 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 2238 earth work in excavation by mechanical means (hydraulic excavator) i manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2239 all kinds of soil.0.00 1.50m 2240 earth work in excavation by mechanical means (hydraulic excavator) i manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2241 all kinds of soil.1.50 3.00m 2242 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 2243 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 2244 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size). 2245 providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing andreinforcement all work up to plinth level : 2246 1:1.5:3 (1 cement : 1.5 coarse sand (zone iii): 3 graded stone aggregate 20 mm nominal size) 2247 centering and shuttering including strutting, propping etc. and removal of form for: 2248 foundations, footings, bases of columns, etc. for mass concrete. 2249 walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 2250 suspended floors, roofs, landings, balconies and access platform. 2251 lintels, beams, plinth beams, girders, bressumers and cantilevers. 2252 edges of slabs and breaks in floors and walls. 2253 under 20 cm wide 2254 reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete. 2255 thermo mechanically treated bars. 2256 cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete 2257 40 mm thick with 20 mm nominal size stone aggregate 2258 6 mm cement plaster of mix : 2259 1:3 (1 cement : 3 fine sand) 2260 providing and fixing in position pre cast r.c.c. manhole cover and frame of required shape and approved quality 2261 m d 10 2262 square shape 450 mm internal dimension 2263 providing and fixing soil, waste and vent pipes 2264 100 mm dia. 2265 centrifugally cast (spun) iron socketed pipe as per is: 3989. 2266 making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and s.w. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. 2267 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 2268 excavating trenches of required width for pipes, cable, etcincluding excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.50m including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. 2269 all kinds of soil 2270 pipes cables etc. exceeding 80 mm dia. but not exceeding 300mm dia. 2271 providing and laying non pressure np2 class (light duty) r.c.c. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 2272 150 mm dia. r.c.c. pipe 2273 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 2274 1:5:10 (1 cement : 5 coarse sand (zone iii): 10 graded stone aggregate 40 mm nominal size). 2275 centering and shuttering including strutting, propping etc. and removal of form for : 2276 foundations, footings, bases of columns, etc. for mass concrete. 2277 constructing brick masonry manholein cement mortar 1 : 4 (1 cement : 4 coarse sand) with rcc top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4gradestone aggregate 20mm nominal size); foundation concrete 1:4:8 mix(1 cement : 4 coarse sand : 8 gradedstoneaggregate40 mm nominalsize) insideplastering 12 mm thickwith cementmortar 1:3 (1cement 3 coarse sand ) finished with a floating coat of neat cement and makingchannels incementconcrete 1:2:4 (1cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finishd with a floating coat ofneatcement completeasper standard design 2278 inside size 90 x 80 cm & 45 cmdeep including ci cover with frame (light duty) 455 x 610mm internal dimensions, total weight of cover & frame to be not lessthan 38 kg (weight of cover 23 kg and weight of frame 15 kg) 2279 with common burnt clay f.p.s.(non modular) bricks of classic designation 7.5 2280 inside size 120 x 90 cm & 90 cmdeep including ci cover with frame (medium duty) 560mm internal diameter, total wt. of cover & frame to be not lessthan 208 kg (wt. of cover 108 kg and wt. of frame 100 kg) 2281 with common burnt clay f.p.s.(non modular) bricks of classic designation 7.5 2282 extra for depth for manholes: 2283 size 90 x 80 cm 2284 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 2285 size 120 x 90 cm 2286 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 2287 providing and fixing square mouths. w. gully trapclass sp 1 complete with c.i. gratingbrickmasonry chamber with water tight ci cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 2288 180 x 150 mm. size p type 2289 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 2290 providing m.s. foot restsorange colour safety footrest 2291 with 20x20 mm square bar 2292 earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2293 all kinds of soil. 2294 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (40% of item no. 1) 2295 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 2296 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 2297 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size). 2298 brick work with f.p.s. bricks of class designation 75 in foundation and plinth in: 2299 cement mortar 1:6 (1 cement : 6 coarse sand) 2300 12 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 2301 1:4 (1 cement: 4 fine sand) 2302 sub feeder panel 2303 incoming 2304 mccb 200a 35ka tpn 2305 indication light 2306 bus bar feeders 2307 200amp alu.bus bar tpn 2308 out going 2309 g/d phase b mccb 125a 35ka tpn 2310 b/d phase b mccb 125a 35ka tpn 2311 type 3 (g+1) mccb 63a 35ka tpn 2312 type 5 mccb 32a 35ka tpn 2313 guest house mccb 32a 35ka tpn 2314 type 3 (g+2) mccb 63a 35ka tpn 2315 type 2 (g+2) mccb 63a 35ka tpn 2316 spare 2317 emergency section 2318 incoming 2319 mcb 125a 63ka tpn 2320 out going 2321 b/d phase b mcb 63a 35ka dp 2322 g/d phase b mcb 63a 35ka dp 2323 type 3 (g+1) mcb 32a 35ka dp 2324 type 5 mcb 32a 35ka dp 2325 guest house mcb 32a 35ka dp 2326 type 3 (g+2) mccb 32a 35ka dp 2327 type 2 (g+1) mccb 32a 35ka dp 2328 type 2 (g) mccb 32a 35ka dp 2329 spare 2330 enclosure 2331 panel body fabricated in 14/16 swg crca sheet , powder coa ted in siemence grey colour complete in all respects universal gland plates. 2332 boys/girls dormitory panel 2333 incoming 2334 100amp mccb tp 35 ka 2335 indication light r,y,b 2336 bus bar feeders 2337 150amp aluminum bus bar tpn 2338 out going 2339 63amp mcb tpn 10ka 2340 63amp mcb tpn 10ka (spare) 2341 emergency section 2342 incoming 2343 63amp mcb dp 10ka 2344 out going 2345 25amp mcb dp 10ka 2346 32amp mcb dp 10ka 2347 enclosure 2348 1050*1450*150 (17 sft) 2349 panel body fabricated in 14/16 swg crca sheet , powder coa ted in siemence grey colour complete in all respects universal gland plates. 2350 vice principal house panel 2351 incoming 2352 63amp mcb tpn 10ka 2353 indication light r,y,b 2354 bus bar feeders 2355 100amp aluminum bus bar tpn 2356 out going 2357 16 32amp mcb 12sp 10ka 2358 32amp mcb dp 10ka 2359 space for 3 phase meter 2360 emergency section 2361 incoming 2362 32amp mcb dp 10ka 2363 16amp mcb dp 10ka 2364 16amp mcb sp 2365 enclosure 2366 650*500*150 (4sft) 2367 panel body fabricated in 14/16 swg crca sheet , powder coa ted in siemence grey colour complete in all respects universal gland plates. 2368 meter panel (type4/type 2 /type3 /guest house) 2369 incoming 2370 mcb 32a 10 ka tpn 2371 indication light r,y,b 2372 bus bar feeders 2373 100amp alu.bus bar tpn 2374 out going 2375 single phase energy meter 2376 mcb 25a dp 2377 emergency section 2378 incoming 2379 mccb 32a dp 2380 out going 2381 16a dp 2382 enclosure 2383 panel body fabricated in 14/16 swg crca sheet , powder coa ted in siemence grey colour complete in all respects universal gland plates. 2384 supply installation, testing and commissioning of external post top lantern with following and complete as required. 2385 6m high (5.0m above ground) 65mm dia gi pole as approved, adopting socket at top for fixture mentioned below, base plate 300x300x6mm and provision for mounting junction box etc. 1 set 2386 erection of pole in cement concrete 400x400x1000mm deep 1:3:6 ratio cement concrete foundation including excavation , refilling, secured with holding clamps, bolts, nuts, alighnment of poles casting etc. including 100 mm thick lean concrete shall be provided at the bottom. 2387 led type 50 watt (street light) light fittings of all types with allaccessories. 2388 suitable size control box with 1 no. incoming and 2 nos. outgoing terminals and 2 nos. tap out terminal with 1 no.5a hrc fuses complet 1 set 2389 suitable number (s) 40mm dia class b gi pipes(s) from above control box to upto 0.5 meter below ground level for power cable entry. 2390 lt cables 2391 supply of following size of 1.1 kv grade multicore aluminium cunductor pvc sheathed armoured cable as per is 1554. 2392 4 core 25 sqmm 2393 4 core 16 sqmm 2394 3.5 core 240 sqmm 2395 3.5 core 95 sqmm 2396 2 core 50 sqmm 2397 2 core 16 sqmm 2398 2 core 10 sqmm 2399 earthingwithgi earth pipe 4.50 meter long 40mm dia including accessories, and providing masonry enclosure with cover plate having lockingarrangement and watering pipe etc.with charcoal or coke and salt complete as required. 2400 earthingwithgi earth plate 600 x 600 x 3mmthickincluding accessories, and providing masonry enclosure with cover plate having lockingarrangement and watering pipe etc.ith watering pipeof 2.7 meter long etc. with charcoal or coke and salt complete as required. (for mltp & dg body) 2401 providing and fixing 25 mm x 5 mm gi strip in 40 mm dia g.i.pipe from earth electrode, including connection with brass nut bolts , spring washer, excavation and refilling etc, as required ( copper gi plate earthing) 2402 providing& layingearth connection from earth electrode with 6 swg dia giwire in 15 mm gi pipe from earth electrode including connection with gi thimbleexcavation and refilling etc as required. ( for gi pipe earthing ofpoles) 2403 providing and fixing 25mm x 5 mm g.i. strips on surface or in recess for connections etc. as required 2404 providing andfixing mvdanger noticeplate of200 mm x 150 mm madeofmild steelatleast 2 mm thickandvitreousenameled white on both sides & with inscription in signalred colour on front side as required.( on 7mts poles & panels) 2405 lt cables laying 2406 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc/ hume/ metal pipe as required. 2407 upto 35 sq. mm 2408 above 35 sq. mm and upto 95 sq. mm 2409 supplying and laying of following size dwc hdpe pipe isi marked along with all accessories like socket, bend, couplers etc. conforming to is 14930, part ii complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 2410 63 mm dia (od 63 mm & id 51 mm nominal) 2411 120 mm dia (od 120 mm & id 103 mm nominal) 2412 supplying and making end termination with brass comperession gland and aluminium lugs for following size of pvc insulated and pvc sheathed/ xlpe aluminium conductor cable of 1.1 kv grade as required 2413 4 core 25 sqmm 2414 4 core 16 sqmm 2415 3.5 core 240 sqmm 2416 3.5 core 95 sqmm 2417 2 core 50 sqmm 2418 2 core 16 sqmm 2419 2 core 10 sqmm 2420 excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 2421 ordinary rock 2422 pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. 2423 providing and laying non pressure np2 class (light duty) r.c.c. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 2424 150 mm dia. r.c.c. pipe ...
Due Date : April 02, 2024
Tender Value : ₹ 9.74 Crore