Military Engineer Services - Bihar

45317672 tender for special repair to buildings no p 73 (urc bldg) at ota gaya; 1 excavating in trenches, n exc 1.5m wide & n exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan & getting out in hard/dense soil 2 excavating in trenches, n exc 1.5m wide & exc 1.5m but n exc 3.0m in depth; for fdn etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan & getting out in hard/dense soil 3 removing excavated soil n exc. 50m & depositing where directed at a level n exc. 1.5 m above the starting point 4 returning, filling in, incl spreading, levelling, watering & well ramming in layers n. exc 25 cm in soil. 5 m & l pcc in foundations, filling and mass concrete type d2 (1:4:8) using 40 mm graded stone aggregate 6 dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete. 7 demolition of concrete of any description and in any position not otherwise specifically provided for complete. 8 demolition ofreinforced cement concrete of any description and in any position not otherwise specifically provided for complete. 9 demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. 10 m & l brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in cm 1:4 11 m & l for brickwork with fly ash bricks straight or curved on plan to any radius in half brick thick walls built in cm (1:4) 12 m & l rcc m 25 design mix using 20 mm graded aggregate in beams, cantilevers, lintels over 1.5 m span 13 m & l rcc m 25 design mix using 20 mm graded aggregate in foundations, incl rafts, footings, foundation beams; plinth beams; bases for columns and mass concrete 14 m & l rcc m 25 design mix using 20 mm graded aggregate in columns, pillars, piers, posts and struts 15 m&l rcc m 25 design mix using 20 mm graded aggregate in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like 16 form work to sides of concrete foundations, footings, bases of columns,sides & soffits of foundation & plinth beams and similar work rough finished surfaces of concrete flat 17 form work to sides of pillars, posts, struts, piers,columns, and stanchions rough finished surfaces of concrete square, rectangular or polygonal 18 formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings & similar work; not exc. 200mm thick (horizontal or sloping) rough finished surfaces of concrete flat 19 m&l mild steel tmt bars 10mm dia & over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality 20 ditto all as per item no 19 above but 6 to 8 mm dia as in spacers and binder 21 s & f of 4 mm thick hpsc (high pressure steam cured) pre primed textured designer board, water resistant, be placed in the grid system duly suspended with 2 mm dia gi bar hangers fixed with steel dash through fasteners from purlins of the roof complete all as specified. 22 m & l for anodised aluminium snap grid frame work for false ceiling all as specified and as directed. 23 m & l for chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and no pigments including 15mm thick sceed bed in cm 1:6 complete. 24 s & f of framed work as in including moulding, cuttings, and made to shape as directed, such as grills, gratings, etc with ends of bars shouldered and/or riveted or welded, or forged into spikes, framed guard bars and similar work conforming to fe.290. gde e 165 complete all as directed & specified. 25 m&l rendering 15mm thick in two coat on stone masonry surfaces or surface other than fair face of brickwork in cm (1:4) finished even & smooth (without using extra cement) and applying wpc on second coat @ 3% by wight of cement or manufacturere instruction 26 m&l rendering 10mm thick on stone masonry surfaces or surface fair face of brickwork in cm (1:6) finished even & smooth (without using extra cement) 27 m & l for hard core of broken bricks gauge n exc. 63mm, deposited, spread & levelled in layers n exc. 15 cm thick, watered & rammed to a true surface 28 m & l 75 mm thick pcc type c 2, (1:3:6) using 40mm graded stone aggregate as inpath and concrete surface finished even and smooth without using extra cement. 29 m & l 25mm thick pcc type b 1, (1:2:4) using 20mm graded stone aggregate as in levelling course for tiles complete. 30 m & l for virified ceramic light shade double charged tiles 7.5 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and incl 15mm thick screed bed or bedding layer with cm 1:4 complete. 31 m & l for virified ceramic light shade double charged tiles 7.5 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in skitting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and incl 10mm thickrendering bed or bedding layer with cm 1:4 complete. 32 m&l rendering 10mm thick on fair faces of brick work or concrete surfaces in cm (1:3) in ceiling complete. 33 m & l for two coats of exterior weather proof paint white or tinted on walls, fascia of roof or chajjas, col facia at any height on old painted surfaces of brick, stone, concrete, asbestos cement or plastered or unplastered surfaces of bldg all as specified & directed.make : asian paints(apex dust proof) or equivalent paint. 34 m & l for preparation of new plastered surfaces and applying two coat of oil bound distemper over a coat of primer including 1mm thick putty complete all as specified and directed by engr in charge. 35 m & l for preparation of old plastered surfaces and applying two coat of oil bound distemper over a coat of primer including 1mm thick putty complete all as specified and directed by engr in charge. 36 m & l 75mm thick pcc type c 1, (1:3:6) using 40mm graded stone aggregate finished even & smooth without using extra cement as in plinth protection/path 37 taking down chowkhats or frames exceeding 1.50 sqm and not exceeding 4 sqm each but with shutters (without taking off shutters from the frame) complete all as specified. 38 s & f ofpressed steel frames 105 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed 39 s & f 30 mm flush shuteers solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. 40 s & f framed work as in doors or gates of angle or other section with gusset plates, rails,braces,etc.,complete, drilled for fixing of steel sheeting or other covering. doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing completeconforming to fe.290.gde e 165 41 material & labour for providing and fixing stainless steel (grade 304) railing made of hollow tubes,channels, plates etc., including welding, grinding,buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement. 42 m&l two coat of synthetic enamel paint overnew woodensurfaces of any description not otherwise described over 10cm in width or grith over one coat of pink primerincluding preparation of surfaces complete. 43 m&l two coat of synthetic enamel paint overold woodensurfaces of any description not otherwise described over 10cm in width or grith over one coat of pink primerincluding preparation of surfaces complete. 44 m&l two coat of syntetic enamel paint overnewsteel surface of any description over 10cm in width or grithnot otherwise describedover one coat red oxide primerincluding preparation of surfaces complete. 45 s & f for powder coated aluminium frame for doors,windows, ventilators with one or morerebates including joining cleat for fixing etc. complete all as specified and directed. 46 s & f aluminium handle cast type anodized 150mm size 47 s & f aluminium, anodized, barrel tower bolts of extruded section 200mm long 48 s&f butt hinge extruded aluminum alloy with galvanized ms hinge pin anodised and fixed 125mm long, type b 21 complete. 49 s & f aluminum alloy, anodized, sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy size 300mm long. 50 m&l for pcc 1:2:4, type b 1 using 20 mm graded stone aggregate as in coping, benching, bed block, lintel band, plinth courses, drains and channels etc including necessary form work complete 51 taking down existing old extg unserviceable lt ug/ service cable of any description and sizecomplete all as specified and directed. 52 supply and laying & testing and commisioning lt underground cable 1100 volts grade, xlpeinsulated and pvc sheathed heavy duty armoured with multi staranded aluminium conductor laid in pipes, trenches/ ducts, on poles etc of sizecomplete all as specified and directed 53 (a) 3.5 core x 120 sqmm 54 (b) 3.5 core x 35 sqmm 55 removing of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. 56 burnt bricks sub class b laid flat dry across the cable for cable protection all as specified and directed. 57 sand cushioning to ug cable 8cm thick before laying the cable and 15cm above the cable, stretching and testing of cable complete all as specified and directed. note: (i) consolidated / punned sand shall be considered for purpose of payment (ii) sand shall be same as specified for plastering work. 58 s & f outdoor type lt feeder piller box of size 600x600x300mm deep, 415 volts, 3 phase, 4 wire 50 hz having 04 nos colour coded aluminium bus bar of capacity 600 amps mounted on porcelain/ hygroscopic insulators with suitable number of holes for making connections of cables, made out of 3.15mm thick sheet steel crca and mounted on frame of suitable size made out of angle iron 50x50x6mm with 4 nos legs embedded in pcc foundation 300mm below ground level and 300mm above ground level, duly painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, dust and vermin proof, front door with locking arrangement and two earth points by side of the box, cubical type with cable glands, sockets etc and with provision of cable entry from bottom, including painting steel frame complete all as specified. 59 m & l for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to gi earth strip 25x4mm by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, pcc chamber, ci frame and cover, ms funnel with wire mesh all as shown in electrical plate no 3 of ssr part i including excavation and earthwork in any type ofsoil/strata and testing on completion. note: gi earth strip 25x4 mm and 40 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted. 60 taking down copper/aluminium point wiring (light, fan, bell, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendent, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc complete all as specified and directed at site. 61 taking down ceiling fan/ exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan bladesand deposit to mes store yard of age e/m gaya complete all as specified and directed. 62 m&l for point wiring with 1.5 sq mm single core pvc insulated unsheathed copper frls multi stranded conductor cable in and including concealed pvc conduit of size 20/25mm isi marked inclusive oftees, bend, elbows etc upto and including sunk in anodized pressed steel box for housing switch socket etc withwhite laminated 3 mm thick hylum sheet cover isi marked of suitable size complete including pvc insulated multi stranded copper conductor 1.5sq mm frls cable as earth wire to common earth dolly for connection to ceiling rose to earth terminalincluding cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed by engr in charge for following : 63 (a) one light point controlled by one, one way switch 5 amps 64 (b) one fan point/ exhaust fan point controlled by one, one way switch 5 amps. 65 (c) one 3 point 5 amps switch socket outlet point controlled by one switch on the same board. 66 (d) one 3 pin 5 amps switch socket outlet point controlled by one switch on independent board. 67 description all as per item no.3 here in before but using 2.5 sqmm single core copper conductor cable of multistranded flame retardant pvc insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant pvc wire as earth continuity conductor along with wiring and connecting to the common earth dolly. 68 description all as per item no.3 here in before but using 4.0 sqmm single core copper conductor frlsh cable of multistranded pvc insulated unsheathed 1100 volts grade for 5/15 amps switch socket combination point including necessary running of4.0 sqmm frlsh pvc insulated copper conductor cable as earth continuity conductor along with wiring and connecting to the common eath dolly. (for ac point) 69 s&f switch piano type single pole 5 amp, 230 volts complete all as specified and directed. 70 s&f switch piano type single pole 15 amp, 230 volts complete all as specified and directed. 71 s&f socket outlet 2 in 1, 3 pin, 5 amp, 230 volts complete all as specified and directed. 72 s&f socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type, 230 volts complete all as specified. 73 s&f ceiling rose, surface bakelite with 3 terminals, isimarked for batten fitting complete all as specified 74 s&f stepped type electronic fan regulator flush type complete all as specified and directed. 75 s&f lamp holder, pvc / polycarbonate type with back plate suitable for batten/ slanting fittings complete all as specified and directed. 76 s&f metal clad box suitable for 230 volt 50 hz ac supplywith 16 amp socket, mcb sp 20/32 amps and 16 amp plug top including removal of old unserviceable one complete all as specified and as directed. 77 m & l for sub main wiring with approved colour coding as per is with two single core pvc insulated frls cable with stranded copper conductor of size 6 sq mm nominal area and drawing into suitable size of pvc non metallic rigid heavy duty pvc conduit of white/ ivory colour and its accessaries isi marked heavy duty of suitable size including concealed in wall etcone run of pvc insulated with 6.0 sqmm (nominal area) stranded copper conductor frls cable as earth wire complete all as specified and as directed. note: two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of pvc conduit will be measured as one unit 78 m & l for sheet metal enclosure mccb dbs, triple pole & neutral 4 way with 200 amp rated bus bar double door suitable for 01 no incoming mccb of 125 amp capacity and 12 nosout going mcb sp complete all as specified and directed. note: mccb & mcbs are measured and paid in separate items. 79 s & f sheet metal enclosure mcb db spn 8 way with 200 amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the dbs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. 80 s & f for mcb single pole and neutral rated capacity 32 amps, 240 volts breaking capacity 10 ka, c curve complete all as specified and as directed. 81 s & ffor mcb single pole rated capacity 6 to 32 amps, 240 volts breaking capacity 10 ka, c curve complete all as specified and as directed. 82 s & f mccb 4 pole, 125 amps with breaking capacity 16 ka, 415 volts complete all as specified and directed. 83 s & f ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 v, 1200 mm sweep, min air delivery 210 cfm with service value 6.00 bee five star rated with brushless direct current motor (bldc) including electrical connections from ceiling rose to fan terminal complete all as specified and directed. 84 labour hanging only ceiling fan obtained from item no. 2 above and connecting up including provision of 3 core pvc insulated pvc sheathed multistranded copper conductor cable of size 23/ 0.193 from ceiling rose to fan terminal and m & l for painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed. 85 s & f for wall mounted led tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouputboxtype fitting, 230 volts and intregrated electronic driver connector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired andnecessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. 86 supply and fixing led luminaire 600 mm x 600 mm, 35/36 watt, 220 v ac recessed type with high efficiency pmma diffuser soft glare free light complete with driver, holders & led lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. 87 s & f led street light fitting 35 watt 230 v ac outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with ip 65/66 protection complete necessary mounting arrangements and provision of 0.75 sqmm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia gi pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by engineer in charge. 88 s & f exhaust fan, steel body ac single phase 230v of size 300mm sweep with, blades, and frame and louvers with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of pvc flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan for connection complete all as specified and directed. 89 m & l for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to gi earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, pcc chamber, ci frame and cover, ms funnel with wire mesh all as shown in electrical plate no 3 of ssr part i including excavation and earthwork in any type ofsoil/strata and testing on completion. note: gi earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted. ...

Rural Development Department - Bihar

42389460 bids are invited for executive table with storage for block level officer , executive visitor chair for sabha bhawan , plastic chair executive with arm , 3 seater waiting bench stainless steel , office almirah large , executive chair revolving , executive chr. revolving for sabha bhawan , conference table , single seater sofa , plastic chair executive with arm and cushion , ac 1.5 ton brand o general with all installation related work with 02 year onsite service and warranty , ahuja wi fi sound system with all fittings in conference room 4 mic for manch and 4 cordless mic , ahuja mobile sound system with 03 cordless mic and 2 fixed mic facility mp3 player with usb , computer table , office printer with photocopy and scan facility , 02 battery 230 amp and inverter set with all wiring work and brand exide v guard microtek with 03 year minimum warranty , wheeled wastebin 240 ltr , wheeled wastebin 120 ltr. , twin dustbin 10 or 12 ltr. foot operated , aluminium partition panel work in sabha bhawan and a makeshift chamber for labour enforcement officer minimum 03 year onsite warranty and maintainance , plastic chair executive without arm , cctv maintainance in block and sabha bhawan underground cable wire work needed some item needed replacement total quantity : 699...

Military Engineer Services - Bihar

40376955 tender for provision of certain minor and revenue works at bihta under age e / m ( af ) of ge ( af ) bihta.; 1 supply, install, fixing and commissioning split type air conditioner with cooling function eer 3.2 of capacity 1.5 tr, five star rated with cordless remote control unit and in built air ioniser, plasma filter for better indoor air quality, five star rated suitable for wall mounted, single phase, 230 / 250 volt ac, with inverter technology and 100% copper coil including breaking necessary hole in wall for fixing indoor and outdoor unit and making good the disturbed surfaces with cement mortar to match with existing finishes after commissioning, making necessary connections unplasticised pvc pipes medium duty 25 mm dia for draining out condensed water all as required including necessary connection complete all as specified and directed.note : ( i ) quoted rates deem to be included cost of drain pipe, copper tubing and 4 sqmm multi standard copper cable ( all 3 mtr length ) , outdoor unit bracket with required fasteners, cutting hole in brick wall etc. ( ii ) installation and commissioning to be done through oem / itsauthorised service centre / agency. 2 s&f sheet metal enclosure with a two pin and earth plug and socket complete with one single pole mcb of 240 volts, 20 amps, c series, 10 ka, complete all as specified and directed. 3 s & f sub main wiring using approved colour coding ( phase red, neutral black, earth green ) complete with two single core frls pvc insulated and unsheathed stranded copper conductor cable 4 sqmm as current carrying conductor and as neutral cable, voltage rating 1100 volt, isi marked drawn in and including concealed pvc conduit isi marked of dia not less than 25 mm and thickness 2 mm with stranded accessories along with one run of frls pvc green colour insulated, unsheathed, stranded copper conductor of size 4 sqmm, complete all as specified and as directed .notes: ( a ) two runs of single core frls pvc cable with one run of earth contunity conductor and conduit shall be measured as one unit. ( b ) cost of cutting chases in wall for concealling conduit and making good to match with existing finish shall be deemed included in the quoted unit rate. 4 supply and fixautomatic copper wound voltage stabilizer for low and high voltage correction equipped with electronic transistorised relay, time relay for two minute suitable for correction on single phase 50 cycles, ac supplyvolt meter indicator and input voltage 180 v to 300 v and stabilized voltage between 220 ±5% of capacity 5 kva, complete all as specified and directed. note : this item shall be fixed with ac catered in respective item of this schedule. 5 excavation in trenches not exc 1.5 m wide and not exc 1.5 m deep for foundation etc or for shafts, column footings or for laying cables etc not exc 10 sqm on plan and getting out in soft / loose soil, complete all as specified and directed. 6 returning, filling in soil including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick complete all as specified and directed. 7 removing excavated materials ( soil ) not exc 50 m distance and depositing where directed at a level not exc 1.5 m above starting point, complete all as specified and directed. 8 supply and laying well burnt old size sub class b bricks as protection to underground cables, laid dry and flat perpendicular to the direction of cable adjoining each other, complete all as specified and directed. 9 m&l fordry andfine river sandfree from sharp materialas incushioning to cablein trenches for cable protectionincludingnecessary punning and consolidation as required, complete all as specified and as directed. ( depth of sand shall be measured after punning ) . 10 supply, laying, jointing and testing of cable xlpe insulated, screened, pvc bedded, galvanised steel strip or wire armoured electric power cable, heavy duty, with aluminium conductor, 1100 volts grade, complete all as specified and directed for thefollowing size of cables: ( a ) cross sectional area 240 sqmm 3½ core 11 ( b ) cross sectional area 50 sqmm 3½ core 12 ( b ) cross sectional area 35 sqmm 3½ core 13 ( b ) cross sectional area 16 sqmm 4 core 14 s&f gi tubing, light grade, with all fittings and laid in trenches / under roads, drains etc, or fixed to poles / walls with fi clamps, nut, bolts etc and making good disturbed surfaces, complete all as specified and directed for the following bore of pipes: ( a ) 40 mm bore 15 ( b ) 50 mm bore 16 ( b ) 15 mm bore 17 m & l for drilling of suitable dia horizontal bore holes suitable for insertion / laying of pipe upto 50 mm of any description below / under road surface, floor etc at site including making good disturbed surface to match with existing strata after laying pipe complete all as specified and directed. 18 supplying, installing, testing & commissioning out door type cubical panel board outer shell made out of3.15 mm thick ms sheet and inner shell made out of 2 mm thick ms sheet and ms angle section 50x50x6 mm mounted on pcc 1:2:4 type b 1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front openable double door system and cable alloy ( each door hinged with body at 3 places with hinges welded to body and door ) lockable / open able by keys having chromium plated 19 mm dia fancy lock, “u” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 volt, 50 hz, tested at factory approved from cpri for 35 mva rupturing capacity at 415 volts factory fabricated having modern fabrication and testing process, complete all as specified and directed and comprising of the following: ( a ) tpn aluminium bus bar 400 amps insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size “f” class insulators not less than 1.0 mtr long. ( b ) incoming mccb200 amps 4 pole 415 volts ac, icu=100%ics, rupturing capacity 25 ka, confirming to is / iec 60947 2 01 no. ( c ) outgoing mccb 100 amps 3 pole 415 volts ac, icu=100%ics, having microprocessor based release for over current, short circuit & earth fault with display and fault discrimination rupturing capacity 25 ka, confirming to is / iec 60947 2 02 nos. ( d ) ditto but mccb 63 amp 1 no. ( e ) mcb tpn32 amps 16 ka 02 nos . ( h ) indicator lamps led type ryb with holder 01 set of three. ( j ) ct coils of suitable ratio 01 set. 19 supply, install, testing and commissioning of out door type cubical feeder pillarbox, tpn of size 600x600x300mm aluminium bus bar 200 amps, outer shell made out of 3.15 mm thick ms sheet inner shell made out of 2.00mm thick ms sheet and ms angle section 40x40x6 mm on pcc 1:2:4 type b 1 platform 60cm above the ground level and 30 cm below the ground level, frame factory fabricated with front and back openable double door system complete suitable for 3 phase 4 wire 415 volt, 50 hz with ip 54. the bus bar shall be provide with sufficient holes for distribution of lt supply to 8 houses single phase and making necessary distributions with the help of thimbles etc, complete all as specified and as directed. 20 m & l for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick, buried directly in ground ( earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised iron strip 25x4 mmas earthing leadby means of bolts, nuts, check nuts, and washers of galvanised iron or steelincluding excavation and earth work, gi pipe medium grade 32 mm bore for protection of gi strip from earth electrodeto test point / machinery / equipment, supplying and laying charcoal dust, common salt, pcc ( 1:2:4 ) type b1 using 20 mm graded crushed stone agregrate chamber andrcc cover 54 cmx54cm x50 mm thick ( 1:2:4 ) type b 1 using 20 mm graded crushed stone aggregates, reinforced with 8 mm dia tmt bars @ 75mm c / c both ways with mild steel handle 12 mm dia, using round bar, pgi funnel with wire mesh, 20 mm dia gi pipe light grade for watering all as shown in electrical plate no 3 of ssr part 1 and testing on completion includingd taking out the oldunserviceable earthing complete all as specified and directed. note cost of gi strip and gi protection pipe up to a distance 7.5 m shall be included in quated rate of above. 21 s & f for 4 pole mccb 63 to 100 amp, 50 hz, 415 v with rupturing capacity 16 ka, ics = 100% of icu, adjustable type, complete all as specified and directed. 22 s&f 40 watt led decorative post top gate light for 360 degree indirect light with ip 65 protection and complete all as directed. 23 m&l for fixing cable junction box lt 3 phase type having ip 66 / 69 weather proof for outdoor installation made of plastic material of size 350x250x138 mm withopaque cover, conical cable gland aluminium lugs, protection class ip 65, 04 nos aluminium bus bar of size 25x4 mm for three phase and neutral including 01 no mcb sp 6 amps for controlling street light and2 nos ms clamp of size 30x5 mm complete with nut, bolt and washers for mounting the junction box on street light pole complete and all as specified and directed by engineer in charge. make sintex product code gsmb 3425 or equivalent make and model as approved by the ge. 24 s&f pvc insulated and pvc sheathed 4.00 sqmm twin core round fr copper conductor industrial cable, 1100 volt grade, conforming to is 694 and making necessary connections from junction box to street light by using suitable size of aluminium thimbles / terminal etc and testing, complete all as specified and as directed. 25 supply and fix gate light controller nature switch of 3 phase 8 kw ( swadeep 66 8kw 3p ) with contactor, incoming mcb & outgoing mcb rating of 32 amps & main load circuit wiring ( copper ) of min size 10 sqmm. the automatic street light control switch using infrared sensor based nature switch for automatic switching of street lights. nature switch operation should be based on natural light lux level. required illuminance level for switching on is =30 lux and for switching off =10 lux.the sensor should also have part night operation facility of minimum 4 hrs to max 12 hrs. the sensor alongwith suitable power contactor ( s ) and incoming and outgoing mcbs should be enclosed in a pole / wall mountable rust proof, electric shock proof, terminate proof and fr grade ip66 protection class 2 enclosure made of thermoplastic polycorbonate and protected against weather influences. the circuit should have provision for manual operation ( i.e. sensor by pass option ) . make of panel consisting of ( i ) nature switch healer ( ii ) contactors bch ( iii ) mcbs hager ( iv ) enclosure hensel, ( v ) circuit wiring polycab. ( vi ) contactor should confirm to iec 60947 4 1 / is 13947 4 1 and mcbs should conform to iec 60898 / is 8828 or another make as approved by the ge. 26 taking down carefully copper / aluminum concealed flame proof point wiring ( light / fan / socket / power ) complete including fittings and fixtures such as switches, ceiling roses, pendents, regulators, sockets, light fittings, sunk box, steel terminal box, laminated sheet with all accessories etc. and making good finish of the disturbed surfaces of walls in line with existing wall etc complete all as specified and as directed. 27 material and labour for 304 grade stainless steel sheet having thickness 3mm for replacing laminated sheet cover wherever required complete with nut, bolt and washers and complete all as directed and specified by engineer in charge. 28 material & labour for fixing spot light bracketmade out of gi pipe light grade 40mm bore approx length not less than 190 cm at a distance of 1 foot from the wall ( for fixing of spot lights ) including new clamps on both ends of the wall, made out of ms flat of size 30x5mm thick including cutting, welding, drilling holes, nut bolts, washer, etc including applying two coats of aluminium paint over one coat of red oxide primer on ms work and complete all asspecified and directed by engineer in charge. 29 s&f led spike light ( spot light ) environmental friendly, new generation, energy saving, decorative type having ip66 protection led spike light using cob led as light source and complete all as directed. make : havells cat part no lycussps15wled730psymbotg or equivalent. 30 m&l for concealed point wiring complete with pvc frls insulated and unsheathed cable 2.5 sqmm ( nominal area ) multi stranded copper conductor single core conforming to is : 694 medium duty concealed stove enamelled steel conduit conformingto is : 9537 ( part 3 ) and isi marked not less than 20 mm dia with concealed in wall pressed steel terminal boxes not less than 1.2 mm thick of required size ( factory made ) including painting terminal boxes inside and outside with two coats of synthetic enamel paint over one coat of red oxide primer and withtop cover 3 mm thick of plastic laminated sheets of required colour complete with all accessoriesand including pvc frls insulated and unsheathed cable 2.5 sqmm ( nominal area ) multi stranded copper conductor single core conforming to is: 694 of green colour as earth wire to common earth and connected to earth dolly drawn in same concealed conduit complete for the following: ( a ) one light / fan / exhaust fan / power socket outlet point controlled by one switch 31 s & f flame proof switch rotary type with termination box in lm 6 / 16a single pole 250 volt all as specified and directed. make shyaam / sudhir or equivalent. 32 supply and fixing stainless steel flexible wire conduit having cross sectional area 30sqmm for enclosing open wire whereever required and complete all as specified and directed by engineer in charge. 33 supply and fixing stainless steel saddle suitable for clamping purpose of above mentioned stainless steel flexible conduit and complete all as specified and directed by engineer in charge. 34 s & f led bollard made up of extruded aluminium with pc diffuser with fitting on gi pipepipe 12 watt with ordering code surya sle bl 12w blk800 or equivalent as approved by the ge, complete all as specified and directed 35 s&f sheet metal enclosure 2 way single door ip 43 with complete including one single pole & neutral mcb 6a 10 ka c series, fixed flush into walls and making good disturbed surfaces, complete all as specified and directed. 36 supplying and fixing 1100 volts grade heavy duty cable pvc insulated aluminium conductor, served with inner sheathing of pvc tape and overall pvc sheathed in service connections 4 sqmm multi stranded, complete all as specified and directed. 37 m&l for conducting of energy audit of complete electrical system of all assets all as specified and directed by engr in charge.notes : ( i ) energy audit company must be registered with bee. ( ii ) the audit must be as per iso 50002:2014. ( iii ) the transformer / vcb / motor / pump set / dg / stabilizer / isolation transformer / cables / oh conductors / lt / ht panels or any other devices / panels / equipment shall be analysed / audited catering all the pump houses and power houses. ( iv ) all the machine / devices / tools / equipment required the rates are included in schedule rates. ( v ) energy audit reports must contain energy consumption / balance and energy efficiency and shall be submitted to ge ( af ) bihta 38 supply and install air conditioner, vertical pack type units indoor / outdoor complete with cordless remote control unit, twin rotary compressor, single phase units 220v 240v, 50 hz of capacity 2.5 tr, with noise supression technology and time temperature display, minimum 3 star rated with all inbuilt and connected accessories provided by company in box, with inverter technology and 100% copper coil, complete all as specified and directed. 39 s & f sub main wiring using approved colour coding ( phase red, neutral black, earth green ) complete with two single core frls pvc insulated and unsheathed stranded copper conductor cable 6 sqmm as current carrying conductor and as neutral cable, voltage rating 1100 volt, isi marked drawn in and including concealed pvc conduit isi marked of dia not less than 25 mm and thickness 2 mm with stranded accessories along with one run of frls pvc green colour insulated, unsheathed, stranded copper conductor of size 6 sqmm, complete all as specified and as directed .notes: ( a ) two runs of single core frls pvc cable with one run of earth contunity conductor and conduit shall be measured as one unit. ( b ) cost of cutting chases in wall for concealling conduit and making good to match with existing finish shall be deemed included in the quoted unit rate. 40 m & l for suction and discharge copper tubing of appropriate dia and thickness suitable for vertical pack type ac of capacity 2.5 tr with black insulating material fixed on it, complete all as specified and directed....

East Central Railway - Bihar

40285846 supply of modification of power line crossing through underground cables upto 33 kv in section of danapur division.modification of power line crossing through underground cables upto 33 kv in section of danapur division.,...

East Central Railway - Bihar

36696398 tender for electrical ( g ) works related to replacement of existing 11 kv overhead conductor of sbpdcl with underground cable for under construction fob near east railway crossing ( lc no. 48 ) , ara...

Central Public Works Department - Bihar

34019430 1. replacement of overhead line by providing ht underground cable at kv, crpf, mokamaghat. 2. providing service connection for residential complex at kv, crpf, mokamaghat....

East Central Railway - Bihar

33350472 removal / shifting of ht ( 11 kv ) & lt over head electric line through underground cable coming in the alignment at obra station and new ror line in ghd section and power supply arrangement at various end cabin in garhwa singrauli section and any other location under dy.cee / con / s / mhx.removal / shifting of ht ( 11 kv ) & lt over head electric line through underground cable coming in the alignment at obra station and new ror line in ghd section and power supply arrangement at various end cabin in garhwa singrauli section and any other location under dy.cee / con / s / mhx., ...

Eastern Railways - Bihar

30814657 supply of improvement of ht network by laying underground cable 3 x 95 sq. mm 11kv ht xlpe cable through hdd machine i.e. jack force method and manually for daulatpur & maidan colony substation at jamalpur and laying of lt cable of daulatpur town supply at different places and straightening & strengthening of electrical poles at different railway colonies, jamalpur...

Central Reserve Police Force - Bihar

30414698 laying of underground cable laying of underground cable of 3.5 core x 70 sqmm at gate no. 03, store block and type iv residential qtr at gc crpf jhaphan muzaffarpur ( bihar ) ...

Eastern Railways - Bihar

29627080 improvement of ht network by laying underground cable 3 x 95 sq. mm 11kv ht xlpe cable through hdd machine i.e. jack force method and manually for daulatpur maidan colony substation at jamalpur and laying of lt cable of daulatpur town supply at different places and straightening strengthening of electrical poles at different railway colonies, jamalpurimprovement of ht network by laying underground cable 3 x 95 sq. mm 11kv ht xlpe cable through hdd machine i.e. jack force method and manually for daulatpur maidan colony substation at jamalpur and laying of lt cable of daulatpur town supply at different places and straightening strengthening of electrical poles at different railway colonies, jamalpur, ...

East Central Railway - Bihar

29369675 modification of power line crossing through underground cables upto 33 kv in section of danapur division.modification of power line crossing through underground cables upto 33 kv in section of danapur division., ...

Bihar State Power Transmission Company Limited - Bihar

29254108 construction of gis gss mithapur and 132kv line through xlpe underground cable on turnkey basis as detailed below: 1) construction of new 3x80mva, 132/33kv gis gss mithapur at agriculture research institute, mithapur and associated works including dismantling of existing mithapur grid system. 2) construction of 132kv transmission line from new gis mithapur to gss karbigahiya through 1200 sqmm xlpe underground cable with associated work including dismantling of existing cable system.(rl 2.7 km)...

East Central Railway - Bihar

29118609 modification of power line crossing through underground cables upto 33 kv in section of danapur division.modification of power line crossing through underground cables upto 33 kv in section of danapur division.,...

Bihar State Power Transmission Company Limited - Bihar

28992300 tender for construction of new 3x80 mva , 132/33kv gis gss mithapur at agriculture research institute, mithapur and associated works including dismantling of existing mithapur grid system, (2) construction of 132 kv transmission line from new gis mithapur to gss karbigathiya through 1200sqmm xlpe underground cable with associated work including dismantling of existing cable system...

Bihar State Power Transmission Company Limited - Bihar

28728650 construction of gis gss mithapur and 132kv line through xlpe underground cable on turnkey basis as detailed below: 1. construction of new 3x80mva, 132 / 33kv gis gss mithapur at agriculture research institute, mithapur and associated works including dismantling of existing mithapur grid system. 2. construction of 132kv transmission line from new gis mithapur to gss karbigahiya through 1200sqmm xlpe underground cable with associated work including dismantling of existing cable system. ( rl 2.7 km ) ...

Bihar State Power Transmission Company Limited - Bihar

28451495 construction of 132kv transmission line from new gis mithapur to gss karbigahiya through 1200 sqmm xlpe underground cable with associated work including dismantling of existing cable system on turnkey basis rl 2.7 km...

Military Engineer Services - Bihar

28410035 repair / maint / replacement of unsv security lights , junction box , lt underground cable , jointing kits , time switch and painting ofpoles in technical , domestic and general area at af stnbihta under ge ( af ) bihta...

Military Engineer Services - Bihar

28410012 repair/maint/replacement of unsv perimeter security lights , junction box , lt underground cable , jointing kits , time switch and painting of poles at af stnbihta under ge ( af ) bihta...

Central Organisation Railway Electrification - Bihar

28382998 modification of 33kv ht ( dvc ) overhead crossing by converting it into underground cable of gr. 201 233modification of 33kv ht ( dvc ) overhead crossing by converting it into underground cable of gr. 201 233, ...

Military Engineer Services - Bihar

28151550 repair/maint/replacement of unsv perimeter security lights , junction box , lt underground cable , jointing kits , time switch and painting of poles at af stnbihta under ge ( af ) bihta repair/maint/replacement of unsv perimeter security lights , junction box , lt underground cable , jointing kits , time switch and painting of poles at af stn bihta under ge ( af ) bihta...

Military Engineer Services - Bihar

28151169 repair/maint/replacement of unsv security lights , junction box , lt underground cable , jointing kits , time switch and painting ofpoles in technical , domestic and general area at af stnbihta under ge ( af ) bihta...

East Central Railway - Bihar

27719152 electrification of newly constructed stations building, quarters, goods shed, pwi office, store, provision of high mast for lighting, power supply arrangement through auxiliary transformer and removal of overhead line through underground cable and left over work at different stations between koderma new gridih station and electrification work of newly constructed tunnel, station quarters in sidhawar meshra section in connection with construction of new bg line.electrification of newly constructed stations building, quarters, goods shed, pwi office, store, provision of high mast for lighting, power supply arrangement through auxiliary transformer and removal of overhead line through underground cable and left over work at different stations between koderma new gridih station and electrification work of newly constructed tunnel, station quarters in sidhawar meshra section in connection with construction of new bg line., ...

Military Engineer Services - Bihar

26824069 provision of storage accn with pgi sheet for hygiene chemical and fol items at klp of 298 i sup pl asc in age br i under ge danapur cantt 1 boring holes 5m deep in soil for single under reamed piles and getting out and disposal of soil to a distance of n.exc 50m ( dia of pile 300mm ) complete all as specified and directed 2 excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth, for foundation etc and getting out in soft / loose soil complete all as specified and directed 3 excavation over areas not exceeding 1.50 m deep and getting out in soft / loose soil complete all as specified and directed. 4 surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out in soft / loose soil complete all as specified and directed 5 m&l for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed 6 m&l pcc 1:4:8 type d2 ( 40mm graded aggregate ) as in foundations, filling and mass concrete.sub base as in floors complete all as specified and directed 7 m & l for brick work with sub class ‘b’ old size bricks straight or curved on plan exc. 6.00 m mean radius built in cement mortar 1:4 complete all as specified and directed. 8 m&l 40 mm thick damp proof course to horizontal or vertical surfaces including necessary form work in cement concrete 1:2:4, type b 0 complete all as specified and directed 9 returning filling in, including spreading, levelling, watering and well ramming in layers, not exc 25 cm in soft / loose soil complete all as specified and directed 10 removing excavated material n exc 50 m and depositing where directed at level n exc 1.5m above the starting point complete all as specified and directed 11 m&l for hard core of gauge n.exc 63 mm deposited, spread and levelled in layers n.exc 15 cm thick with broken bricks, watered and rammed to a true surface complete all as specified. 12 m&l reinforced cement concrete ( m 25 design mix ) ( using 20 mm graded stone aggregate ) in foundation, footing, foundation beams, plinth beams, bases for columns, pedestal, under reamed piles, mass concrete, etc complete all as specified and directed 13 m&l reinforced cement concrete ( m 25 design mix ) ( using 20mm graded stone aggregate ) as in columns, pillars, posts, struts etc complete all as specified and directed 14 m&lfor providing reinforced cement concrete m 25 design mix using 20mm graded aggregate as in beams, cantilevers, bressmummers, lintels over 1.5 m span complete all as directed 15 form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits ( if any ) of foundation and plinth beams; and similar work; vertical or to batter for rough finished flat surfaces of concrete complete all as specified and directed 16 form work to sides of pillars, posts, struts, piers, columns and stanchions for rough finished , square, rectangular or polygonal surfaces of concrete complete all as directed 17 form work to edges of concrete flats, treads, breaks in floors window cills, concrete railing, openings in concrete walls, floor and roofs n exc 20 cm wide and side of rcc / pcc bands in walls, horizontal or sloping and similar work complete all as specified and directed 18 formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed 19 m&l ms tmt bars, 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hoopinbg for columns, hooking ends and binding with and including ms wire ( annealed ) not less than 0.9 mm dia or securing with clips complete all as specified and directed 20 ditto all as per item no 19 above but 5 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders complete all as specified and directed 21 m&l for rendering 15 mm thick in cement mortar 1:4, in two layers ( 1st layer 10 mm thick rendering coat and 2nd layer 5 mm thick finishing coat ) on brick work or concrete surfaces, second layer ( finishing coat ) mixed with liquid water proofing compound @ 200 ml / 50 kg bag of cement as per manufacturers instructions and finished the surfaces even and fair without using extra cement complete all as specified and directed. nnote : liquid wpc will be measured and paid separately. 22 supply only water proofing compound ( liquid ) , isi marked complete all as specified and directed. 23 m&l 15 mm thick rendering on fair faces of bk / concrete surfaces in cm ( 1:6 ) , finished even and smooth ( without using extra cement ) complete all as specified and directed. 24 m&l rendering 10mm thick in cm 1:4 on concrete surfacves / chajja / ceiling, etc finished even and smooth without using extra cement complete all as specified and directed. 25 m&l for preparation of new plastered surfaces of wall and applying two coats of cement base paint over a coat of cement primer complete all as specified and directed. 26 m&l for prepration of new plastered surfaces of ceiling and applying three coats of white wash complete all as directed 27 m&l prepration of new plastered surfaces of wall and applying three coats of white wash complete all as directed 28 m&l for prepration of new steel surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as directed 29 m&l for preparing surfaces of new wood and wood based materials of any description and girth, not otherwise described and treated with two coats of synthetic enamel paint over a coat of pink primer complete all as directed 30 m & l for 75 mm thick pcc 1:3:6 type c 2 using 20mm graded stone aggregate including finished surface even & fair without using extra cement as in plinth protection including necessary form work of edge complete all as specified and directed. nnote : 10mm wide and 75mm deep joints shall be made at 3 mtr intervel and at each corner and the same shall be filled with using bitumen 85 / 25 and sand in the ratio 1:3. 31 m & l for 20 25 mm thick machine cut kota stone slab as in flooring over and including 15mm thick screed base in cement mortor ( 1:6 ) , laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including necessary grinding, rubbing, rounding to exposed edges and polishing in granite finish complete all as specified and directed.. 32 m & l for 20 25 mm thick machine cut kota stone slab as in risers of steps, skirting, dado and pillar over and including 10 mm thick rendering in cement mortor ( 1:4 ) , laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including necessary grinding, rubbing, rounding to exposed edges and polishing in granite finish complete all as specified and directed. 33 s&f steel windows with side hung shutter incl box type butt hinges with bow handle, steel peg stay, tower bolts ( each shutter having two tower bolts 100mm long ) complete with glazing bars dovetailed or welded complete all as specified and directed. 34 s&f mild steel framed works such as grills, gratings, etc, with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work for portions framed and hung as gates, including pintle hinges, stops, hand made sliding bolts, etc conforming to fe 290 gde e 165 complete all as specified and directed. 35 s&f pressed steel frames ( factory made ) made out of 1.25 mm thick black ms sheet for doors, with one or more rebates including necessary fixing lugs, butt hinges, lock strike plate, etc complete, size of frame 105 x 60 mm incl bottom of each chowkat to be welded with 2 nos 25x25x3mm thick flat iron projecting 10 cm on either side and back fill to chowkats with pcc 1:3:6 type c o using 12.5 mm graded crushed stone aggregate complete all as specified and directed. 36 s & f of 35 mm thick ( batten thickness ) factory made plain, framed, panelled shutters ( two panels ) with lock rail and panel of 9 mm thick bwp commercial ply or 12 mm thick veneered particle board with commercial veneering on both faces and size of the members of shutter are as per is – 1003 ( part – i ) made of kiln seasoned & chemically pressure treated 2nd class hardwood complete all as specified and directed. 37 s&f mild steel works as in hold fasts, clamps, plain angle cleats for securing purlins to wood trusses or rafters, and similar small conforming to fe 410 0 or fe 310 0 complete all as specified and directed. 38 m&l pcc 1:2:4 type b1 ( using 20mm graded aggregate ) as in bed blocks for hold fasts including necessary from work, pcc benching, copings etc. complete all as specified and directed. 39 s&f 4mm thick sheet glass, ordinary quality glazing with oil putty in square n.exc 0.50 sqm in each pane of complete all as specified and directed. 40 s&f butt hinges ( isi marked ) , medium weight, cold rolled mild steel of size 100 mm complete all as specified and directed. 41 s&f 150 mm long aluminum anodised barrel tower bolts of extruded section complete all as specified and directed. 42 s&f aluminium handles, cast type, anodized 150 mm size comp isi marked complete all as specified and directed. 43 m&l 75 mm thick cement concrete type c2, 1:3:6 , ( 40 mm graded aggregate ) as in sub base floor finished even & fair complete all as specified and directed. 44 m&l 100 mm thick pcc 1:2:4 type b 2 ( using 40 mm graded aggregate ) as in floor, finishing cement concrete surface, spike rolling or making impression of expanded metal whilst the concrete in green complete all as spd and direced 45 forming 150mm deep x12mm thick expansion joints filled with pre formed bituminous filler and 30mm primed and sealed with sealing compound grade b complete. 46 s&f roof trusses ( framed ) , trussed, purlins, crane gantries, rails and fastening and heavy bracket framing ( beam, tee, angle, channel or flat sections ) including distance pieces, cleats etc complete all as specified and directed by e in charge. 47 s&f pre painted galvalume aluminium zinc coating gi based corrugated steel sheet 0.50mm thick of an colour having tensile strentth of 550 mps as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed by e in charge 48 s&f pre painted galvalume aluminium zinc coating gi based plain steel sheet 0.50mm thick of an colour having tensile strentth of 550 mps as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed by e in charge 49 m & l for point wiring with pvc insulated and pvc unsheathed electric frls cable of 1100v single core having multi stranded copper conductor of size 1.5 sqmm nominal cross sectional area & including non metallic rigid pvc conduit isi marked medium grade not less than 20mm dia with all conduit accessories in concealed wiring system by cutting of wall and making good disturbed surface of wall ( cutting except on ceiling for fan point only, on ceiling instead of pvc conduit surface casing caping will be used ) & 1.5 sqmm green pvc insulated unsheathed copper conductor as a earth wire connected to earth dolly by providing lugs including ms boxes for mounting switches, sockets, fan regulators etc for one light point controlled by one switch complete all as specified and directed. 50 all as per ser item no. 49 here in before but one 5 amps socket out let point controlled by one switch on same board with another switches complete all as specified and directed at site. 51 supply and fixing switch piano flush button single pole one way 5 amps, 230 volts complete all as specified and directed. 52 supply and fixing socket outlet flush type 5 amps, 5 pin, 240 volts complete all as specified and directed. 53 supply and fixing ceiling rose surface bakelite 63.5mm dia three terminal, fixied complete all as specified and as directed. 54 supply and fixing double door spn dbs four way of powder coated dbs suitable for mcbs fitted with bus bar, neutral link, earth bar and din ral complete all as specified and directed . make: l&t / legrand / schneider n 55 supply and fixing with mcb spn 5 to 40 amps 10 ka , c series including connection with suitable size aluminium / copper lugs complete all as specified and directed . make: l&t / legrand / schneider 56 supply and fixing mcb sp 240 volts 5 to 32 amps, 10 ka breaking capacity, c type including connection with suitable size aluminium / copper lugs complete all as specified and directed .make: l&t / legrand / schneider n 57 supply and fixing led tube light flameproof batten suitable for single and twin t 8 type tube rod of 16 / 20 watt including driver with t 8 type two nos. of 16 / 20 watt led tube rod, recommended for gas / vapour group and ip 65 protected complete with all accessories internally pre wired and fixed to wall / ceiling incl fittings accessories and incl connecting upto ceiling rose with three core twisted flexible copper conductor cable pvc sheathed suitable size all as specified. make crompton cat no: extn2lt8 16 / 20 or equivalent model of bajaj / philips / havells. 58 supply and fixing led bulk head 10 watt fittings environmental friendly ultra modern energy saving surface mounted decorataive bulk head fitting with driver and prewired and necessary electric connection with pvc insulated twin twisted flexible copper wire of size 0.75 sqmm complete all as specified and as directed. make: havells cat no: hexaft10wled857ssymbopc or equivalent model of bajaj / cg. 59 supply and fixing in repair of earthing to panel with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground ( earth pit not less than 2.25m below normal ground level ) with top edge of earth plate not less than 1.5m below normal ground level connected to galvanised earth lead wire 4.0mm dia by means of bolts, nut, check nuts and washers of galvanized iron or steel all as shown in electrical plate no.3 of mes schedule pt i 2009, gi earth lead strip protected by gi pipe 40 mm dia light grade and connected to earth test point including excavation in any type of soil, returning filling, disposal of soil, providing charcoal dust and common salt upto top edge of earth plate, construction of pcc pit with rcc cover, funnel, watering pipe of 20mm dia gi light grade and provision of earth test point including testing on completion complete 60 supply , laying & testing in repair for xlpe insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs complete of size 10 sqmm nominal cross section x 2 core.make of cable: polycab / havells / finolex / grandlay / mescab 61 m & l dry sand cushioning to underground cables with 8cm thick before laying of cables and 15cm thick after laying and stretching of cable and gentally hand ramming and consolidation of thickness of sand 18 cm all as specified and directed by engr in charge. note : sand thickness shall be measured 18 cm only after punning of sand . 62 m&l for bricks cover of old size bricks sub class b with width equal to the length of the brick laid dry & flet abutted with with each other with gap between adjacent bricks n.exc 10 mm over ug cable for protection compete. 63 supply and fixing of gi tubing, light grade, 40 mm bore with all fitting lais in trenches / pole / wall for protection of cables in repairs complete....

Military Engineer Services - Bihar

25001406 repair / maintenance / replacement of unsv security lights , junction box , lt underground cable , jointing kits , time switch and painting ofpoles in technical domestic and general area at af stnbihta under ge ( af ) bihta...

Military Engineer Services - Bihar

25001402 repair / maintenance / replacement of unsv perimeter security lights , junction box , lt underground cable , jointing kits , time switch and painting to poles at af stn bihta under ge ( af ) bihta...

Military Engineer Services - Bihar

24846510 repair / maintenance of earth pits , lightning conductor , street lights , dg sets , amf panel , lt panel , underground cable and connected item ( s ) of work at af stn darbhanaga under ge ( af ) bihta...

Military Engineer Services - Bihar

24795342 repair/maintenance/replacement of unsv perimeter security lights , junction box , lt underground cable , jointing kits , time switch and painting ofpoles at af stnbihta under ge ( af ) bihta...

Military Engineer Services - Bihar

24795037 repair/maintenance/replacement of unsv security lights , junction box , lt underground cable , jointing kits , time switch and painting ofpoles in technical domestic and general area at af stnbihta under ge ( af ) bihta...

Military Engineer Services - Bihar

24472276 repair/maint/replacement of unsv security lights , junction box , lt underground cable , jointing kits , time switch and painting ofpoles in technical domestic and general area at af stnbihta under ge ( af ) bihta repair/maint/replacement of unsv security lights , junction box , lt underground cable , jointing kits , time switch and painting of poles in technical domestic and general area at af stnbihta under ge ( af ) bihta...

Military Engineer Services - Bihar

24472158 repair / maintenance / replacement of unsv perimeter security lights , junction box , lt underground cable , jointing kits , time switch and painting ofpoles at af stnbihta under ge ( af ) bihta...

Military Engineer Services - Bihar

24274237 tender for repair/maintenance/replacement of u nsv security lights, junction box, lt underground cable, jointing kits, time switch and painting to poles in technical, domestic and general area at af stn bihta under ge (af) bihta....

Military Engineer Services - Bihar

24274214 tender for repair/maintenance of earth pits, lightning conductor street lights, dg sets, amf panel, lt panel, underground cable and connected i item (s) of work at af stn darbhanga under ge (af) bihta...

Military Engineer Services - Bihar

24274101 tender for repair/maintenance of lt underground cable, acsr conductor, panels and allied works at af stn darbhanga under ge (af) bihta....

Military Engineer Services - Bihar

24274059 tender for repair/maintenance/replacement of unsv perimeter security lights, junction box, lt underground cable, jointing kits, time switch and painting of poles at af stn bihta under ge (af) bihta....

Ordnance Factory - Bihar

23856460 supply and laying of 11kv underground cable from mrss to qa lab outdoor substation at ofn, rajgir=> open tender ( indigenous ) ...

Government College - Bihar

21694533 tender for electrification work in administrative & newly constructed building with underground cable....