Provision Of Storage Accn With Pgi Sheet For Hygiene Chemical And Fol Items At Klp Of 298 I Sup Pl Asc In Age Br I Under Ge Danapur Cantt - 1 Boring Holes 5M Deep In Soil For Single Under Reamed Piles And Getting Out And Disposal Of Soil To A Distance Of N.Exc 50M ( Dia Of Pile 300Mm ) Complete All As Specified And Directed 2 Excavation In Trenches, N Exc 1.5M Wide And N Exc 1.5M In Depth, For Foundation Etc And Getting Out In Soft / Loose Soil Complete All As Specified And Directed 3 Excavation Over Areas Not Exceeding 1.50 M Deep And Getting Out In Soft / Loose Soil Complete All As Specified And Directed. 4 Surface Excavation N Exc 30 Cm Deep And Averaging 15 Cm Deep And Getting Out In Soft / Loose Soil Complete All As Specified And Directed 5 M&L For Sand Filling Under Floors Or In Foundations Including Watering And Consolidation Complete All As Specified And Directed 6 M&L Pcc 1:4:8 Type-D2 ( 40Mm Graded Aggregate ) As In Foundations, Filling And Mass Concrete.Sub Base As In Floors Complete All As Specified And Directed 7 M & L For Brick Work With Sub Class ‘B’ Old Size Bricks Straight Or Curved On Plan Exc. 6.00 M Mean Radius Built In Cement Mortar 1:4 Complete All As Specified And Directed. 8 M&L 40 Mm Thick Damp Proof Course To Horizontal Or Vertical Surfaces Including Necessary Form Work In Cement Concrete 1:2:4, Type B-0 Complete All As Specified And Directed 9 Returning Filling In, Including Spreading, Levelling, Watering And Well Ramming In Layers, Not Exc 25 Cm In Soft / Loose Soil Complete All As Specified And Directed 10 Removing Excavated Material N Exc 50 M And Depositing Where Directed At Level N Exc 1.5M Above The Starting Point Complete All As Specified And Directed 11 M&L For Hard Core Of Gauge N.Exc 63 Mm Deposited, Spread And Levelled In Layers N.Exc 15 Cm Thick With Broken Bricks, Watered And Rammed To A True Surface Complete All As Specified. 12 M&L Reinforced Cement Concrete ( M-25 Design Mix ) ( Using 20 Mm Graded Stone Aggregate ) In Foundation, Footing, Foundation Beams, Plinth Beams, Bases For Columns, Pedestal, Under Reamed Piles, Mass Concrete, Etc Complete All As Specified And Directed 13 M&L Reinforced Cement Concrete ( M-25 Design Mix ) ( Using 20Mm Graded Stone Aggregate ) As In Columns, Pillars, Posts, Struts Etc Complete All As Specified And Directed 14 M&Lfor Providing Reinforced Cement Concrete M-25 Design Mix Using 20Mm Graded Aggregate As In Beams, Cantilevers, Bressmummers, Lintels Over 1.5 M Span Complete All As Directed 15 Form Work To Sides Of Concrete Foundations, Footings, Bases Of Columns, Raft And Raft Beams, Sides And Soffits ( If Any ) Of Foundation And Plinth Beams; And Similar Work; Vertical Or To Batter For Rough Finished Flat Surfaces Of Concrete Complete All As Specified And Directed 16 Form Work To Sides Of Pillars, Posts, Struts, Piers, Columns And Stanchions For Rough Finished , Square, Rectangular Or Polygonal Surfaces Of Concrete Complete All As Directed 17 Form Work To Edges Of Concrete Flats, Treads, Breaks In Floors Window Cills, Concrete Railing, Openings In Concrete Walls, Floor And Roofs N Exc 20 Cm Wide And Side Of Rcc / Pcc Bands In Walls, Horizontal Or Sloping And Similar Work Complete All As Specified And Directed 18 Formwork To Sides And Soffits Of Floor Or Roof Beams, Beam Haunchings, Girders, Bressummers, Lintels, Cantilevers, Shelves Including Supports, Overhangs, Etc. Also Splays Between Floors And Beams, Etc Complete All As Specified And Directed 19 M&L Ms Tmt Bars, 10 Mm Dia And Over, Cut To Length, Bent To Shape Required, Including Cranking, Bending Spirally For Hoopinbg For Columns, Hooking Ends And Binding With And Including Ms Wire ( Annealed ) Not Less Than 0.9 Mm Dia Or Securing With Clips Complete All As Specified And Directed 20 Ditto All As Per Item No 19 Above But 5 Mm Dia And Over Upto And Including 10 Mm Dia In Stirrups, Spacers And Binders Complete All As Specified And Directed 21 M&L For Rendering 15 Mm Thick In Cement Mortar 1:4, In Two Layers ( 1St Layer 10 Mm Thick Rendering Coat And 2Nd Layer 5 Mm Thick Finishing Coat ) On Brick Work Or Concrete Surfaces, Second Layer ( Finishing Coat ) Mixed With Liquid Water Proofing Compound @ 200 Ml / 50 Kg Bag Of Cement As Per Manufacturers Instructions And Finished The Surfaces Even And Fair Without Using Extra Cement Complete All As Specified And Directed. Nnote : Liquid Wpc Will Be Measured And Paid Separately. 22 Supply Only Water Proofing Compound ( Liquid ) , Isi Marked Complete All As Specified And Directed. 23 M&L 15 Mm Thick Rendering On Fair Faces Of Bk / Concrete Surfaces In Cm ( 1:6 ) , Finished Even And Smooth ( Without Using Extra Cement ) Complete All As Specified And Directed. 24 M&L Rendering 10Mm Thick In Cm 1:4 On Concrete Surfacves / Chajja / Ceiling, Etc Finished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed. 25 M&L For Preparation Of New Plastered Surfaces Of Wall And Applying Two Coats Of Cement Base Paint Over A Coat Of Cement Primer Complete All As Specified And Directed. 26 M&L For Prepration Of New Plastered Surfaces Of Ceiling And Applying Three Coats Of White Wash Complete All As Directed 27 M&L Prepration Of New Plastered Surfaces Of Wall And Applying Three Coats Of White Wash Complete All As Directed 28 M&L For Prepration Of New Steel Surfaces Of Any Description, Not Otherwise Described, Over 10Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer Complete All As Directed 29 M&L For Preparing Surfaces Of New Wood And Wood Based Materials Of Any Description And Girth, Not Otherwise Described And Treated With Two Coats Of Synthetic Enamel Paint Over A Coat Of Pink Primer Complete All As Directed 30 M & L For 75 Mm Thick Pcc 1:3:6 Type C-2 Using 20Mm Graded Stone Aggregate Including Finished Surface Even & Fair Without Using Extra Cement As In Plinth Protection Including Necessary Form Work Of Edge Complete All As Specified And Directed. Nnote : 10Mm Wide And 75Mm Deep Joints Shall Be Made At 3 Mtr Intervel And At Each Corner And The Same Shall Be Filled With Using Bitumen 85 / 25 And Sand In The Ratio 1:3. 31 M & L For 20 - 25 Mm Thick Machine Cut Kota Stone Slab As In Flooring Over And Including 15Mm Thick Screed Base In Cement Mortor ( 1:6 ) , Laid And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Necessary Grinding, Rubbing, Rounding To Exposed Edges And Polishing In Granite Finish Complete All As Specified And Directed.. 32 M & L For 20 - 25 Mm Thick Machine Cut Kota Stone Slab As In Risers Of Steps, Skirting, Dado And Pillar Over And Including 10 Mm Thick Rendering In Cement Mortor ( 1:4 ) , Laid And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Necessary Grinding, Rubbing, Rounding To Exposed Edges And Polishing In Granite Finish Complete All As Specified And Directed. 33 S&F Steel Windows With Side Hung Shutter Incl Box Type Butt Hinges With Bow Handle, Steel Peg Stay, Tower Bolts ( Each Shutter Having Two Tower Bolts 100Mm Long ) Complete With Glazing Bars Dovetailed Or Welded Complete All As Specified And Directed. 34 S&F Mild Steel Framed Works Such As Grills, Gratings, Etc, With Ends Of Bars Shouldered And / Or Riveted, Or Forged Into Spikes; Framed Guard Bars; Barred Iron Doors; Ladders; Framed Balusters; Walk Ways; Railings; Framework Of Water Tanks And Similar Work For Portions Framed And Hung As Gates, Including Pintle Hinges, Stops, Hand Made Sliding Bolts, Etc Conforming To Fe 290 Gde -E-165 Complete All As Specified And Directed. 35 S&F Pressed Steel Frames ( Factory Made ) Made Out Of 1.25 Mm Thick Black Ms Sheet For Doors, With One Or More Rebates Including Necessary Fixing Lugs, Butt Hinges, Lock Strike Plate, Etc Complete, Size Of Frame 105 X 60 Mm Incl Bottom Of Each Chowkat To Be Welded With 2 Nos 25X25x3mm Thick Flat Iron Projecting 10 Cm On Either Side And Back Fill To Chowkats With Pcc 1:3:6 Type C-O Using 12.5 Mm Graded Crushed Stone Aggregate Complete All As Specified And Directed. 36 S & F Of 35 Mm Thick ( Batten Thickness ) Factory Made Plain, Framed, Panelled Shutters ( Two Panels ) With Lock Rail And Panel Of 9 Mm Thick Bwp Commercial Ply Or 12 Mm Thick Veneered Particle Board With Commercial Veneering On Both Faces And Size Of The Members Of Shutter Are As Per Is – 1003 ( Part – I ) Made Of Kiln Seasoned & Chemically Pressure Treated 2Nd Class Hardwood Complete All As Specified And Directed. 37 S&F Mild Steel Works As In Hold Fasts, Clamps, Plain Angle Cleats For Securing Purlins To Wood Trusses Or Rafters, And Similar Small Conforming To Fe 410-0 Or Fe 310-0 Complete All As Specified And Directed. 38 M&L Pcc 1:2:4 Type B1 ( Using 20Mm Graded Aggregate ) As In Bed Blocks For Hold Fasts Including Necessary From Work, Pcc Benching, Copings Etc. Complete All As Specified And Directed. 39 S&F 4Mm Thick Sheet Glass, Ordinary Quality Glazing With Oil Putty In Square N.Exc 0.50 Sqm In Each Pane Of Complete All As Specified And Directed. 40 S&F Butt Hinges ( Isi Marked ) , Medium Weight, Cold Rolled Mild Steel Of Size 100 Mm Complete All As Specified And Directed. 41 S&F 150 Mm Long Aluminum Anodised Barrel Tower Bolts Of Extruded Section Complete All As Specified And Directed. 42 S&F Aluminium Handles, Cast Type, Anodized 150 Mm Size Comp Isi Marked Complete All As Specified And Directed. 43 M&L 75 Mm Thick Cement Concrete Type C2, 1:3:6 , ( 40 Mm Graded Aggregate ) As In Sub Base Floor Finished Even & Fair Complete All As Specified And Directed. 44 M&L 100 Mm Thick Pcc 1:2:4 Type B-2 ( Using 40 Mm Graded Aggregate ) As In Floor, Finishing Cement Concrete Surface, Spike Rolling Or Making Impression Of Expanded Metal Whilst The Concrete In Green Complete All As Spd And Direced 45 Forming 150Mm Deep X12mm Thick Expansion Joints Filled With Pre-Formed Bituminous Filler And 30Mm Primed And Sealed With Sealing Compound Grade B Complete. 46 S&F Roof Trusses ( Framed ) , Trussed, Purlins, Crane Gantries, Rails And Fastening And Heavy Bracket Framing ( Beam, Tee, Angle, Channel Or Flat Sections ) Including Distance Pieces, Cleats Etc Complete All As Specified And Directed By E-In-Charge. 47 S&F Pre-Painted Galvalume Aluminium Zinc Coating Gi Based Corrugated Steel Sheet 0.50Mm Thick Of An Colour Having Tensile Strentth Of 550 Mps As In Roof Covering / Cladding To Wall, Fixed With Self Tapping Screws Complete All As Specified And Directed By E-In-Charge 48 S&F Pre-Painted Galvalume Aluminium Zinc Coating Gi Based Plain Steel Sheet 0.50Mm Thick Of An Colour Having Tensile Strentth Of 550 Mps As In Roof Covering / Cladding To Wall, Fixed With Self Tapping Screws Complete All As Specified And Directed By E-In-Charge 49 M & L For Point Wiring With Pvc Insulated And Pvc Unsheathed Electric Frls Cable Of 1100V Single Core Having Multi Stranded Copper Conductor Of Size 1.5 Sqmm Nominal Cross Sectional Area & Including Non Metallic Rigid Pvc Conduit Isi Marked Medium Grade Not Less Than 20Mm Dia With All Conduit Accessories In Concealed Wiring System By Cutting Of Wall And Making Good Disturbed Surface Of Wall ( Cutting Except On Ceiling For Fan Point Only, On Ceiling Instead Of Pvc Conduit Surface Casing Caping Will Be Used ) & 1.5 Sqmm Green Pvc Insulated Unsheathed Copper Conductor As A Earth Wire Connected To Earth Dolly By Providing Lugs Including Ms Boxes For Mounting Switches, Sockets, Fan Regulators Etc For One Light Point Controlled By One Switch Complete All As Specified And Directed. 50 All As Per Ser Item No. 49 Here-In-Before But One 5 Amps Socket Out Let Point Controlled By One Switch On Same Board With Another Switches Complete All As Specified And Directed At Site. 51 Supply And Fixing Switch Piano Flush Button Single Pole One Way 5 Amps, 230 Volts Complete All As Specified And Directed. 52 Supply And Fixing Socket Outlet Flush Type 5 Amps, 5 Pin, 240 Volts Complete All As Specified And Directed. 53 Supply And Fixing Ceiling Rose Surface Bakelite 63.5Mm Dia Three Terminal, Fixied Complete All As Specified And As Directed. 54 Supply And Fixing Double Door Spn Dbs Four Way Of Powder Coated Dbs Suitable For Mcbs Fitted With Bus Bar, Neutral Link, Earth Bar And Din Ral Complete All As Specified And Directed . Make: L&T / Legrand / Schneider N 55 Supply And Fixing With Mcb Spn 5 To 40 Amps 10 Ka , C-Series Including Connection With Suitable Size Aluminium / Copper Lugs Complete All As Specified And Directed . Make: L&T / Legrand / Schneider 56 Supply And Fixing Mcb Sp 240 Volts 5 To 32 Amps, 10 Ka Breaking Capacity, C Type Including Connection With Suitable Size Aluminium / Copper Lugs Complete All As Specified And Directed .Make: L&T / Legrand / Schneider N 57 Supply And Fixing Led Tube Light Flameproof Batten Suitable For Single And Twin T-8 Type Tube Rod Of 16 / 20 Watt Including Driver With T-8 Type Two Nos. Of 16 / 20 Watt Led Tube Rod, Recommended For Gas / Vapour Group And Ip-65 Protected Complete With All Accessories Internally Pre Wired And Fixed To Wall / Ceiling Incl Fittings Accessories And Incl Connecting Upto Ceiling Rose With Three Core Twisted Flexible Copper Conductor Cable Pvc Sheathed Suitable Size All As Specified. Make- Crompton Cat No:-Extn2lt8-16 / 20 Or Equivalent Model Of Bajaj / Philips / Havells. 58 Supply And Fixing Led Bulk Head 10 Watt Fittings Environmental Friendly Ultra Modern Energy Saving Surface Mounted Decorataive Bulk Head Fitting With Driver And Prewired And Necessary Electric Connection With Pvc Insulated Twin Twisted Flexible Copper Wire Of Size 0.75 Sqmm Complete All As Specified And As Directed. Make: Havells Cat No: Hexaft10wled857ssymbopc Or Equivalent Model Of Bajaj / Cg. 59 Supply And Fixing In Repair Of Earthing To Panel With Galvanised Steel Earth Plate Electrode 60Cm X 60Cm X 6Mm Thick, Buried Directly In Ground ( Earth Pit Not Less Than 2.25M Below Normal Ground Level ) With Top Edge Of Earth Plate Not Less Than 1.5M Below Normal Ground Level Connected To Galvanised Earth Lead Wire 4.0Mm Dia By Means Of Bolts, Nut, Check Nuts And Washers Of Galvanized Iron Or Steel All As Shown In Electrical Plate No.3 Of Mes Schedule Pt-I 2009, Gi Earth Lead Strip Protected By Gi Pipe 40 Mm Dia Light Grade And Connected To Earth Test Point Including Excavation In Any Type Of Soil, Returning Filling, Disposal Of Soil, Providing Charcoal Dust And Common Salt Upto Top Edge Of Earth Plate, Construction Of Pcc Pit With Rcc Cover, Funnel, Watering Pipe Of 20Mm Dia Gi Light Grade And Provision Of Earth Test Point Including Testing On Completion Complete 60 Supply , Laying & Testing In Repair For Xlpe Insulated, Armoured, Heavy Duty Electric Cable With Stranded Aluminium Conductor, 1100 Volts Grade, Laid In Trenches, Sleeving Through Pipes Or Fixed On Poles & Walls Or Laid Under Floors Including Jointing With Suitable Size Aluminium Lugs Complete Of Size 10 Sqmm Nominal Cross Section X 2 Core.Make Of Cable: Polycab / Havells / Finolex / Grandlay / Mescab 61 M & L Dry Sand Cushioning To Underground Cables With 8Cm Thick Before Laying Of Cables And 15Cm Thick After Laying And Stretching Of Cable And Gentally Hand Ramming And Consolidation Of Thickness Of Sand 18 Cm All As Specified And Directed By Engr - In - Charge. Note :- Sand Thickness Shall Be Measured 18 Cm Only After Punning Of Sand . 62 M&L For Bricks Cover Of Old Size Bricks Sub Class B With Width Equal To The Length Of The Brick Laid Dry & Flet Abutted With With Each Other With Gap Between Adjacent Bricks N.Exc 10 Mm Over Ug Cable For Protection Compete. 63 Supply And Fixing Of Gi Tubing, Light Grade, 40 Mm Bore With All Fitting Lais In Trenches / Pole / Wall For Protection Of Cables In Repairs Complete.

Tender Notice

26824069

Military Engineer Services

Indian


Bihar

February 23, 2021

Key Value

Ref. Documents

Ref. Documents

Ref. Documents

To Download Tender Document Click on the below link

Provision Of Storage Accn With Pgi Sheet For Hygiene Chemical And Fol Items At Klp Of 298 I Sup Pl Asc In Age Br I Under Ge Danapur Cantt - 1 Boring Holes 5M Deep In Soil For Single Under Reamed Piles And Getting Out And Disposal Of Soil To A Distance Of N.Exc 50M ( Dia Of Pile 300Mm ) Complete All As Specified And Directed 2 Excavation In Trenches, N Exc 1.5M Wide And N Exc 1.5M In Depth, For Foundation Etc And Getting Out In Soft / Loose Soil Complete All As Specified And Directed 3 Excavation Over Areas Not Exceeding 1.50 M Deep And Getting Out In Soft / Loose Soil Complete All As Specified And Directed. 4 Surface Excavation N Exc 30 Cm Deep And Averaging 15 Cm Deep And Getting Out In Soft / Loose Soil Complete All As Specified And Directed 5 M&L For Sand Filling Under Floors Or In Foundations Including Watering And Consolidation Complete All As Specified And Directed 6 M&L Pcc 1:4:8 Type-D2 ( 40Mm Graded Aggregate ) As In Foundations, Filling And Mass Concrete.Sub Base As In Floors Complete All As Specified And Directed 7 M & L For Brick Work With Sub Class ‘B’ Old Size Bricks Straight Or Curved On Plan Exc. 6.00 M Mean Radius Built In Cement Mortar 1:4 Complete All As Specified And Directed. 8 M&L 40 Mm Thick Damp Proof Course To Horizontal Or Vertical Surfaces Including Necessary Form Work In Cement Concrete 1:2:4, Type B-0 Complete All As Specified And Directed 9 Returning Filling In, Including Spreading, Levelling, Watering And Well Ramming In Layers, Not Exc 25 Cm In Soft / Loose Soil Complete All As Specified And Directed 10 Removing Excavated Material N Exc 50 M And Depositing Where Directed At Level N Exc 1.5M Above The Starting Point Complete All As Specified And Directed 11 M&L For Hard Core Of Gauge N.Exc 63 Mm Deposited, Spread And Levelled In Layers N.Exc 15 Cm Thick With Broken Bricks, Watered And Rammed To A True Surface Complete All As Specified. 12 M&L Reinforced Cement Concrete ( M-25 Design Mix ) ( Using 20 Mm Graded Stone Aggregate ) In Foundation, Footing, Foundation Beams, Plinth Beams, Bases For Columns, Pedestal, Under Reamed Piles, Mass Concrete, Etc Complete All As Specified And Directed 13 M&L Reinforced Cement Concrete ( M-25 Design Mix ) ( Using 20Mm Graded Stone Aggregate ) As In Columns, Pillars, Posts, Struts Etc Complete All As Specified And Directed 14 M&Lfor Providing Reinforced Cement Concrete M-25 Design Mix Using 20Mm Graded Aggregate As In Beams, Cantilevers, Bressmummers, Lintels Over 1.5 M Span Complete All As Directed 15 Form Work To Sides Of Concrete Foundations, Footings, Bases Of Columns, Raft And Raft Beams, Sides And Soffits ( If Any ) Of Foundation And Plinth Beams; And Similar Work; Vertical Or To Batter For Rough Finished Flat Surfaces Of Concrete Complete All As Specified And Directed 16 Form Work To Sides Of Pillars, Posts, Struts, Piers, Columns And Stanchions For Rough Finished , Square, Rectangular Or Polygonal Surfaces Of Concrete Complete All As Directed 17 Form Work To Edges Of Concrete Flats, Treads, Breaks In Floors Window Cills, Concrete Railing, Openings In Concrete Walls, Floor And Roofs N Exc 20 Cm Wide And Side Of Rcc / Pcc Bands In Walls, Horizontal Or Sloping And Similar Work Complete All As Specified And Directed 18 Formwork To Sides And Soffits Of Floor Or Roof Beams, Beam Haunchings, Girders, Bressummers, Lintels, Cantilevers, Shelves Including Supports, Overhangs, Etc. Also Splays Between Floors And Beams, Etc Complete All As Specified And Directed 19 M&L Ms Tmt Bars, 10 Mm Dia And Over, Cut To Length, Bent To Shape Required, Including Cranking, Bending Spirally For Hoopinbg For Columns, Hooking Ends And Binding With And Including Ms Wire ( Annealed ) Not Less Than 0.9 Mm Dia Or Securing With Clips Complete All As Specified And Directed 20 Ditto All As Per Item No 19 Above But 5 Mm Dia And Over Upto And Including 10 Mm Dia In Stirrups, Spacers And Binders Complete All As Specified And Directed 21 M&L For Rendering 15 Mm Thick In Cement Mortar 1:4, In Two Layers ( 1St Layer 10 Mm Thick Rendering Coat And 2Nd Layer 5 Mm Thick Finishing Coat ) On Brick Work Or Concrete Surfaces, Second Layer ( Finishing Coat ) Mixed With Liquid Water Proofing Compound @ 200 Ml / 50 Kg Bag Of Cement As Per Manufacturers Instructions And Finished The Surfaces Even And Fair Without Using Extra Cement Complete All As Specified And Directed. Nnote : Liquid Wpc Will Be Measured And Paid Separately. 22 Supply Only Water Proofing Compound ( Liquid ) , Isi Marked Complete All As Specified And Directed. 23 M&L 15 Mm Thick Rendering On Fair Faces Of Bk / Concrete Surfaces In Cm ( 1:6 ) , Finished Even And Smooth ( Without Using Extra Cement ) Complete All As Specified And Directed. 24 M&L Rendering 10Mm Thick In Cm 1:4 On Concrete Surfacves / Chajja / Ceiling, Etc Finished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed. 25 M&L For Preparation Of New Plastered Surfaces Of Wall And Applying Two Coats Of Cement Base Paint Over A Coat Of Cement Primer Complete All As Specified And Directed. 26 M&L For Prepration Of New Plastered Surfaces Of Ceiling And Applying Three Coats Of White Wash Complete All As Directed 27 M&L Prepration Of New Plastered Surfaces Of Wall And Applying Three Coats Of White Wash Complete All As Directed 28 M&L For Prepration Of New Steel Surfaces Of Any Description, Not Otherwise Described, Over 10Cm Width Or Girth And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer Complete All As Directed 29 M&L For Preparing Surfaces Of New Wood And Wood Based Materials Of Any Description And Girth, Not Otherwise Described And Treated With Two Coats Of Synthetic Enamel Paint Over A Coat Of Pink Primer Complete All As Directed 30 M & L For 75 Mm Thick Pcc 1:3:6 Type C-2 Using 20Mm Graded Stone Aggregate Including Finished Surface Even & Fair Without Using Extra Cement As In Plinth Protection Including Necessary Form Work Of Edge Complete All As Specified And Directed. Nnote : 10Mm Wide And 75Mm Deep Joints Shall Be Made At 3 Mtr Intervel And At Each Corner And The Same Shall Be Filled With Using Bitumen 85 / 25 And Sand In The Ratio 1:3. 31 M & L For 20 - 25 Mm Thick Machine Cut Kota Stone Slab As In Flooring Over And Including 15Mm Thick Screed Base In Cement Mortor ( 1:6 ) , Laid And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Necessary Grinding, Rubbing, Rounding To Exposed Edges And Polishing In Granite Finish Complete All As Specified And Directed.. 32 M & L For 20 - 25 Mm Thick Machine Cut Kota Stone Slab As In Risers Of Steps, Skirting, Dado And Pillar Over And Including 10 Mm Thick Rendering In Cement Mortor ( 1:4 ) , Laid And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Necessary Grinding, Rubbing, Rounding To Exposed Edges And Polishing In Granite Finish Complete All As Specified And Directed. 33 S&F Steel Windows With Side Hung Shutter Incl Box Type Butt Hinges With Bow Handle, Steel Peg Stay, Tower Bolts ( Each Shutter Having Two Tower Bolts 100Mm Long ) Complete With Glazing Bars Dovetailed Or Welded Complete All As Specified And Directed. 34 S&F Mild Steel Framed Works Such As Grills, Gratings, Etc, With Ends Of Bars Shouldered And / Or Riveted, Or Forged Into Spikes; Framed Guard Bars; Barred Iron Doors; Ladders; Framed Balusters; Walk Ways; Railings; Framework Of Water Tanks And Similar Work For Portions Framed And Hung As Gates, Including Pintle Hinges, Stops, Hand Made Sliding Bolts, Etc Conforming To Fe 290 Gde -E-165 Complete All As Specified And Directed. 35 S&F Pressed Steel Frames ( Factory Made ) Made Out Of 1.25 Mm Thick Black Ms Sheet For Doors, With One Or More Rebates Including Necessary Fixing Lugs, Butt Hinges, Lock Strike Plate, Etc Complete, Size Of Frame 105 X 60 Mm Incl Bottom Of Each Chowkat To Be Welded With 2 Nos 25X25x3mm Thick Flat Iron Projecting 10 Cm On Either Side And Back Fill To Chowkats With Pcc 1:3:6 Type C-O Using 12.5 Mm Graded Crushed Stone Aggregate Complete All As Specified And Directed. 36 S & F Of 35 Mm Thick ( Batten Thickness ) Factory Made Plain, Framed, Panelled Shutters ( Two Panels ) With Lock Rail And Panel Of 9 Mm Thick Bwp Commercial Ply Or 12 Mm Thick Veneered Particle Board With Commercial Veneering On Both Faces And Size Of The Members Of Shutter Are As Per Is – 1003 ( Part – I ) Made Of Kiln Seasoned & Chemically Pressure Treated 2Nd Class Hardwood Complete All As Specified And Directed. 37 S&F Mild Steel Works As In Hold Fasts, Clamps, Plain Angle Cleats For Securing Purlins To Wood Trusses Or Rafters, And Similar Small Conforming To Fe 410-0 Or Fe 310-0 Complete All As Specified And Directed. 38 M&L Pcc 1:2:4 Type B1 ( Using 20Mm Graded Aggregate ) As In Bed Blocks For Hold Fasts Including Necessary From Work, Pcc Benching, Copings Etc. Complete All As Specified And Directed. 39 S&F 4Mm Thick Sheet Glass, Ordinary Quality Glazing With Oil Putty In Square N.Exc 0.50 Sqm In Each Pane Of Complete All As Specified And Directed. 40 S&F Butt Hinges ( Isi Marked ) , Medium Weight, Cold Rolled Mild Steel Of Size 100 Mm Complete All As Specified And Directed. 41 S&F 150 Mm Long Aluminum Anodised Barrel Tower Bolts Of Extruded Section Complete All As Specified And Directed. 42 S&F Aluminium Handles, Cast Type, Anodized 150 Mm Size Comp Isi Marked Complete All As Specified And Directed. 43 M&L 75 Mm Thick Cement Concrete Type C2, 1:3:6 , ( 40 Mm Graded Aggregate ) As In Sub Base Floor Finished Even & Fair Complete All As Specified And Directed. 44 M&L 100 Mm Thick Pcc 1:2:4 Type B-2 ( Using 40 Mm Graded Aggregate ) As In Floor, Finishing Cement Concrete Surface, Spike Rolling Or Making Impression Of Expanded Metal Whilst The Concrete In Green Complete All As Spd And Direced 45 Forming 150Mm Deep X12mm Thick Expansion Joints Filled With Pre-Formed Bituminous Filler And 30Mm Primed And Sealed With Sealing Compound Grade B Complete. 46 S&F Roof Trusses ( Framed ) , Trussed, Purlins, Crane Gantries, Rails And Fastening And Heavy Bracket Framing ( Beam, Tee, Angle, Channel Or Flat Sections ) Including Distance Pieces, Cleats Etc Complete All As Specified And Directed By E-In-Charge. 47 S&F Pre-Painted Galvalume Aluminium Zinc Coating Gi Based Corrugated Steel Sheet 0.50Mm Thick Of An Colour Having Tensile Strentth Of 550 Mps As In Roof Covering / Cladding To Wall, Fixed With Self Tapping Screws Complete All As Specified And Directed By E-In-Charge 48 S&F Pre-Painted Galvalume Aluminium Zinc Coating Gi Based Plain Steel Sheet 0.50Mm Thick Of An Colour Having Tensile Strentth Of 550 Mps As In Roof Covering / Cladding To Wall, Fixed With Self Tapping Screws Complete All As Specified And Directed By E-In-Charge 49 M & L For Point Wiring With Pvc Insulated And Pvc Unsheathed Electric Frls Cable Of 1100V Single Core Having Multi Stranded Copper Conductor Of Size 1.5 Sqmm Nominal Cross Sectional Area & Including Non Metallic Rigid Pvc Conduit Isi Marked Medium Grade Not Less Than 20Mm Dia With All Conduit Accessories In Concealed Wiring System By Cutting Of Wall And Making Good Disturbed Surface Of Wall ( Cutting Except On Ceiling For Fan Point Only, On Ceiling Instead Of Pvc Conduit Surface Casing Caping Will Be Used ) & 1.5 Sqmm Green Pvc Insulated Unsheathed Copper Conductor As A Earth Wire Connected To Earth Dolly By Providing Lugs Including Ms Boxes For Mounting Switches, Sockets, Fan Regulators Etc For One Light Point Controlled By One Switch Complete All As Specified And Directed. 50 All As Per Ser Item No. 49 Here-In-Before But One 5 Amps Socket Out Let Point Controlled By One Switch On Same Board With Another Switches Complete All As Specified And Directed At Site. 51 Supply And Fixing Switch Piano Flush Button Single Pole One Way 5 Amps, 230 Volts Complete All As Specified And Directed. 52 Supply And Fixing Socket Outlet Flush Type 5 Amps, 5 Pin, 240 Volts Complete All As Specified And Directed. 53 Supply And Fixing Ceiling Rose Surface Bakelite 63.5Mm Dia Three Terminal, Fixied Complete All As Specified And As Directed. 54 Supply And Fixing Double Door Spn Dbs Four Way Of Powder Coated Dbs Suitable For Mcbs Fitted With Bus Bar, Neutral Link, Earth Bar And Din Ral Complete All As Specified And Directed . Make: L&T / Legrand / Schneider N 55 Supply And Fixing With Mcb Spn 5 To 40 Amps 10 Ka , C-Series Including Connection With Suitable Size Aluminium / Copper Lugs Complete All As Specified And Directed . Make: L&T / Legrand / Schneider 56 Supply And Fixing Mcb Sp 240 Volts 5 To 32 Amps, 10 Ka Breaking Capacity, C Type Including Connection With Suitable Size Aluminium / Copper Lugs Complete All As Specified And Directed .Make: L&T / Legrand / Schneider N 57 Supply And Fixing Led Tube Light Flameproof Batten Suitable For Single And Twin T-8 Type Tube Rod Of 16 / 20 Watt Including Driver With T-8 Type Two Nos. Of 16 / 20 Watt Led Tube Rod, Recommended For Gas / Vapour Group And Ip-65 Protected Complete With All Accessories Internally Pre Wired And Fixed To Wall / Ceiling Incl Fittings Accessories And Incl Connecting Upto Ceiling Rose With Three Core Twisted Flexible Copper Conductor Cable Pvc Sheathed Suitable Size All As Specified. Make- Crompton Cat No:-Extn2lt8-16 / 20 Or Equivalent Model Of Bajaj / Philips / Havells. 58 Supply And Fixing Led Bulk Head 10 Watt Fittings Environmental Friendly Ultra Modern Energy Saving Surface Mounted Decorataive Bulk Head Fitting With Driver And Prewired And Necessary Electric Connection With Pvc Insulated Twin Twisted Flexible Copper Wire Of Size 0.75 Sqmm Complete All As Specified And As Directed. Make: Havells Cat No: Hexaft10wled857ssymbopc Or Equivalent Model Of Bajaj / Cg. 59 Supply And Fixing In Repair Of Earthing To Panel With Galvanised Steel Earth Plate Electrode 60Cm X 60Cm X 6Mm Thick, Buried Directly In Ground ( Earth Pit Not Less Than 2.25M Below Normal Ground Level ) With Top Edge Of Earth Plate Not Less Than 1.5M Below Normal Ground Level Connected To Galvanised Earth Lead Wire 4.0Mm Dia By Means Of Bolts, Nut, Check Nuts And Washers Of Galvanized Iron Or Steel All As Shown In Electrical Plate No.3 Of Mes Schedule Pt-I 2009, Gi Earth Lead Strip Protected By Gi Pipe 40 Mm Dia Light Grade And Connected To Earth Test Point Including Excavation In Any Type Of Soil, Returning Filling, Disposal Of Soil, Providing Charcoal Dust And Common Salt Upto Top Edge Of Earth Plate, Construction Of Pcc Pit With Rcc Cover, Funnel, Watering Pipe Of 20Mm Dia Gi Light Grade And Provision Of Earth Test Point Including Testing On Completion Complete 60 Supply , Laying & Testing In Repair For Xlpe Insulated, Armoured, Heavy Duty Electric Cable With Stranded Aluminium Conductor, 1100 Volts Grade, Laid In Trenches, Sleeving Through Pipes Or Fixed On Poles & Walls Or Laid Under Floors Including Jointing With Suitable Size Aluminium Lugs Complete Of Size 10 Sqmm Nominal Cross Section X 2 Core.Make Of Cable: Polycab / Havells / Finolex / Grandlay / Mescab 61 M & L Dry Sand Cushioning To Underground Cables With 8Cm Thick Before Laying Of Cables And 15Cm Thick After Laying And Stretching Of Cable And Gentally Hand Ramming And Consolidation Of Thickness Of Sand 18 Cm All As Specified And Directed By Engr - In - Charge. Note :- Sand Thickness Shall Be Measured 18 Cm Only After Punning Of Sand . 62 M&L For Bricks Cover Of Old Size Bricks Sub Class B With Width Equal To The Length Of The Brick Laid Dry & Flet Abutted With With Each Other With Gap Between Adjacent Bricks N.Exc 10 Mm Over Ug Cable For Protection Compete. 63 Supply And Fixing Of Gi Tubing, Light Grade, 40 Mm Bore With All Fitting Lais In Trenches / Pole / Wall For Protection Of Cables In Repairs Complete.