Supply Of Supply, Installation & Commissioning Of Smps Based Ips Confirming To Rdso Specification No. Rdso / Spn / 165 / 2012 ( Ver.3.0 ) Or Latest Amdt. And Sketch No. Sdo / Ips / Pi-4L / Nre / 001 For Ips Up To 4 Lines Without Aftc Non-Re Area Along With 300 Ah Low Maint. Lead Acid Battery.Supply, Installation & Commissioning Of Smps Based Ips Confirming To Rdso Specification No. Rdso / Spn / 165 / 2012 ( Ver.3.0 ) Or Latest Amdt. And Sketch No. Sdo / Ips / Pi-4L / Nre / 001 For Ips Up To 4 Lines Without Aftc Non-Re Area Along With 300 Ah Low Maint. Lead Acid Battery., Supply, Installation & Commissioning Of Smps Based Ips Confirming To Rdso Specification No. Rdso / Spn / 165 / 2012 ( Ver.3.0 ) Or Latest Amdt. And Sketch No. Sdo / Ips / Pi-4L / Nre / 001 For Ips Up To 4 Lines Without Aftc Non-Re Area Along With 300 Ah Low Maint. Lead Acid Battery. Technical Specification: A. Specification No. :- Rdso / Spn / 165 / 2012 ( Ver 3.0 ) B. Applicable Sketch No. Sdo / Ips / Pi / 4L / Nre / 001 C. Type Of Battery:300Ah Lmla Or Vrla. D. Dc-Dc Converter For Ssi / Data Logger:-Yes , All Optional Items Are Required. E. Dc-Dc Converter For Axle Counter-Yes, Required F. Dc-Dc Converter For Block Working : [ 12-40V, 1 Amp ] , Or [ 40-100V, 1 Amp ] , Or [ 24- 32V, 5A ] To Be Decided At The Time Of Loa. G. Type Of External & Internal Relays;24 V, Q Series Relays H. Dc-Dc Converter [ 03-6V / .1A ] 04 Nos. For Block Telephone / Mt I. Distance Between Ips Room To Asm Panel [ In Meter ] ; 50-100 Meter J.Distance Between Ips Rack & Battery [ In Meter ] 20-30 Meter. K. Whether Installation Is To Be Done By Oem-Yes. L. Supply Of Spares Required As Per List Given Below: Sn Sub System Spares Components Qty. ( 1 ) Smps: Charger Module Module ( As Cold Standby ) 01 Module. ( 2 ) Inverter Module Module ( As Cold Standby ) 01 Module. ( 3 ) Dc-Dc Converter Dc-Dc Converter For Relay Internal Relay External And Block Line Or As Required By The Purchaser 01 Module Each. ( 4 ) Ferro-Resonant Automatic Voltage- Regulator ( Avr ) Ac Capacitor 01 Set. ( 5 ) Fuses All Type Of Fuses Used In Ips Sub-System 01 Set. ( 6 ) Transformer Modular ( As Cold Standby ) 02 Module. ( 7 ) Inverter / Smr Dc Fan 02 Nos. ( 8 ) Cells 2V Cells 05 Nos.

Tender Notice

27936513

East Central Railway

Indian


Bihar

June 28, 2021

Key Value

Ref. Documents

Ref. Documents

Ref. Documents

To Download Tender Document Click on the below link

Supply Of Supply, Installation & Commissioning Of Smps Based Ips Confirming To Rdso Specification No. Rdso / Spn / 165 / 2012 ( Ver.3.0 ) Or Latest Amdt. And Sketch No. Sdo / Ips / Pi-4L / Nre / 001 For Ips Up To 4 Lines Without Aftc Non-Re Area Along With 300 Ah Low Maint. Lead Acid Battery.Supply, Installation & Commissioning Of Smps Based Ips Confirming To Rdso Specification No. Rdso / Spn / 165 / 2012 ( Ver.3.0 ) Or Latest Amdt. And Sketch No. Sdo / Ips / Pi-4L / Nre / 001 For Ips Up To 4 Lines Without Aftc Non-Re Area Along With 300 Ah Low Maint. Lead Acid Battery., Supply, Installation & Commissioning Of Smps Based Ips Confirming To Rdso Specification No. Rdso / Spn / 165 / 2012 ( Ver.3.0 ) Or Latest Amdt. And Sketch No. Sdo / Ips / Pi-4L / Nre / 001 For Ips Up To 4 Lines Without Aftc Non-Re Area Along With 300 Ah Low Maint. Lead Acid Battery. Technical Specification: A. Specification No. :- Rdso / Spn / 165 / 2012 ( Ver 3.0 ) B. Applicable Sketch No. Sdo / Ips / Pi / 4L / Nre / 001 C. Type Of Battery:300Ah Lmla Or Vrla. D. Dc-Dc Converter For Ssi / Data Logger:-Yes , All Optional Items Are Required. E. Dc-Dc Converter For Axle Counter-Yes, Required F. Dc-Dc Converter For Block Working : [ 12-40V, 1 Amp ] , Or [ 40-100V, 1 Amp ] , Or [ 24- 32V, 5A ] To Be Decided At The Time Of Loa. G. Type Of External & Internal Relays;24 V, Q Series Relays H. Dc-Dc Converter [ 03-6V / .1A ] 04 Nos. For Block Telephone / Mt I. Distance Between Ips Room To Asm Panel [ In Meter ] ; 50-100 Meter J.Distance Between Ips Rack & Battery [ In Meter ] 20-30 Meter. K. Whether Installation Is To Be Done By Oem-Yes. L. Supply Of Spares Required As Per List Given Below: Sn Sub System Spares Components Qty. ( 1 ) Smps: Charger Module Module ( As Cold Standby ) 01 Module. ( 2 ) Inverter Module Module ( As Cold Standby ) 01 Module. ( 3 ) Dc-Dc Converter Dc-Dc Converter For Relay Internal Relay External And Block Line Or As Required By The Purchaser 01 Module Each. ( 4 ) Ferro-Resonant Automatic Voltage- Regulator ( Avr ) Ac Capacitor 01 Set. ( 5 ) Fuses All Type Of Fuses Used In Ips Sub-System 01 Set. ( 6 ) Transformer Modular ( As Cold Standby ) 02 Module. ( 7 ) Inverter / Smr Dc Fan 02 Nos. ( 8 ) Cells 2V Cells 05 Nos.