Bids Are Invited For Pile - Boring, Providing And Installation Bored Cast-In-Situ Reinforced Cement Concrete Piles Of Grade M-25 Of Specified Diameter And Length Below The Pile Cap, To Carry A Safe Working Load Not Less Than Specified, Excluding The Cost Of Steel Reinforcement But Including The Cost Of Boring With Bentonite Solution And Temporary Casing Of Appropriate Length For Setting Out And Removal Of Same And The Length Of The Pile To Be Embedded In The Pile Cap Etc. By Percussion Drilling Using Direct Mud Circulation ( Dmc ) Or Bailer And Chisel Technique By Tripod And Mechanical Winch Machine All Complete, Including Removal Of Excavated Earth With All Its Lifts And Leads ( Length Of Pile For Payment Shall Be Measured Up To Bottom Of Pile Cap ) .450Mm Dia Piles ( Inclusive Of Carriage ) , Pcc - Providing And Laying In Position Cement Concrete Of Specified Gradeexcluding The Cost Of Centering And Shuttering - All Work Up To Plinthlevel : 1:3:6 ( 1 Cement : 3 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) ( Inclusive Of Carriage ) , Rcc - Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland / Portland Slag Cement, Admixtures In Recommended Proportion As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge; For The Following Grades Of Concrete. Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. ( Inclusive Of Carriage ) , Brick Work - Brick Work With Bricks Of Class Designation 100A In Foundations And Plinthin :Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) ( Inclusive Of Carriage ) , Sand Filing - Supplying And Filling In Plinth With Sand Under Floors, Including Watering, Ramming, Consolidating And Dressing Complete. ( Inclusive Of Carriage ) With Lead Upto 3 Km , Shuttering - Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete , Reinforment Steel - Steel Reinforcement For R.C.C. Work Ready To Use Cut And Bend Rebars Of Approved Make From Factory / Workshop To Construction Site Including Placing In Position And Binding All Complete Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. , Plinth Protection - Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) Over 75Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Necessary Excavation, Levelling & Dressing & Finishing The Top Smooth. , Door & Window - Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. ( Glazing, Paneling And Dash Fasteners To Be Paid For Separately ) :Powder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) , Glass - Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item ) :With Float Glass Panes Of 5 Mm Thickness ( Weight Not Less Than 12.50 Kg / Sqm ) , Upvc Door - Providing And Fixing Of Factory Made Upvc White Colour Casement Door, Upvc Multichambered Extruted Frame, Sash And Mullion Profile. Frame Duly Reinforced With 1.2Mm Gi Section Box Tpe Chamber And Sash With 1.5Mm Thick Gi Section ( ± 0.2Mm ) Based On Wind Load Calculations ( Shape And Size According To Upvc Profiles ) , Appropiate Dimentions Of Upvc Extruded Glazing Bead, Epdm Gasket ( K / O Type ) , Seperate Drainage System, Ss34 Grade Friction Hinges 2D / 3D Plate Hinges, Zinc Alloy ( White Powder Coated ) Casement Handle, Gi Fastener 8X100 Mm Size For Fixing Frame To Finish Wall, Plastic Packer And Caps And Necessary Steel Screws Etc.Profile Of Frame And Sash Shall Be Metered Cut And Fusion Welded At All Corners, Mullion Shall Be Also Fusion Welded / Joined Mechanically Including Drilling Of Holes For Fixing Hardware And Drainage Of Water Etc. After Fixing Of Frames , Gap Between Frame And Adjascent Wall Shall Be Filled With Pu Foaam / Backer Rod Required Size And The Approved Quantity. After That Sealed With Weather Proof Silicon Sealant At Both Side, All Complete As Per Approved Drawing And Direction Of Eic , Door Closer - Providing And Fixing Aluminium Die Cast Body Tubular Type Universal Hydraulic Door Closer ( Having Brand Logo With Isi, Is : 3564, Embossed On The Body, Door Weight Upto 35 Kg And Door Width Upto 700 Mm ) , With Necessary Accessories And Screws Etc. Complete. , Door - Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 ( Part I ) Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters. 30 Mm Thick Including Stainless Steel Butt Hinges Wirhnecessary Screws , Door Stopper - Providing And Fixing Aluminium Hanging Floor Door Stopper, Isi Marked, Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour And Shade, With Necessary Screws Etc. Complete. Single Rubber Stopper , Soling - Providing Designation 100 A One Brick Flat Soling Joints Filled With Local Sand Including Cost Of Watering, Taxes, Royalty All Complete As Perbuilding Specification And Direction Of E / L, , Tile 1 - Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3 Kg / Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , Tile 2 - Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm ( Thickness To Be Specified By The Manufacturer ) Of 1St Quality Conforming To Is : 15622 Of Approved Make In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3 Kg / Sqm Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete. , Tile 3 - Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 ( Thickness To Be Specified By The Manufacturer ) , Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , Granite - Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm ( Average ) Thick Base Of Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge :Flamed Finish Granite Stone Slab Jet Black, Cherry Red, Elitebrown, Cat Eye Or Equivalent. , False Ceiling - Providing And Fixing Mineral Fibre False Ceiling Tiles At All Heights Of Size 595X595mm Of Approved Texture, Design And Pattern. The Tiles Should Have Humidity Resistance ( Rh ) Of 99%, Light Reflectance ? 85%, Thermal Conductivity K = 0.052 - 0.057 W / M K, Fire Performance As Per ( Bs 476 Pt - 6 &7 ) In True Horizontal Level Suspended On Interlocking T-Grid Of Hot Dipped All Round Galvanized Iron Section Of 0.33 Mm Thick ( Galvanized @120 Gsm ) Comprising Of Main T Runners Of 15X32 Mm Of Length 3000 Mm, Cross T Of Size 15X32mm Of Length 1200 Mm And Secondary Intermediate Cross T Of Size 15X32 Mm Of Length 600 Mm To Form Grid Module Of Size 600X600 Mm Suspended From Ceiling Using Galvanized Mild Steel Item ( Galvanised@80Gsm ) 50 Mm Long 8Mmwith 16 Mm Thick Beveled Tegular Mineral Fibre AntiMicrobial False Ceiling Tile Confirming To Iso 5 ( Class 100 ) Specifications , Pre-Fabsteel - Designing, Providing, Installing And Fixing Factory Finished Custom Designed Cold Form Light Gauge Steel Framed Super Structure Comprising Of Steel Wall Panel, Trusses, Purlins Etc Manufactured Out Of Minimum 0.75 Mm Thick Steel Sheet As Per Design Requirements. The Steel Sheet Shall Be Galvanized ( Az-150Gms Aluminium Zinc Alloy Coated Steel Having Minimum Yield Strength 300-550 Mpa ) Conforming To Aisi Specifications And Ibc 2009 For Cold Formed Steel Framing And Construction And Also As Per Is: 875-1987, Iso 800-1984 And Is:801- 1975. The Wind Load Shall Be As Per Provisions Of Is 875 ( Part -Iii ) . Lgsfs Frame Shall Be Designed As Per Is: 801 Using Commercially Available Software Such As Frame Cad Pro-11.7 / Staad Pro-V8i / Architekv2.5.16 / Revit Architecture-2011 Or Equivalent. Proper Usage Of Connection Accessories Like Heavy Duty Tension Ties, Light Duty Hold-Ons, Twist Straps ( To Connect Truss With Wall Frames ) , Strong Tie, Tie Rod, H-Brackets, Boxing Sections, L-Shaped Angles For Better Structural Stability. The Framing Section Shall Be Cold Form C-Type Having Minimum Web Depth 89 Mm X 39Mm Flange X 11Mm Lip In Required Length As Per Structural Design Requirement Duly Punched With Dimple / Slot At Required Locations As Per Approved Drawings. , Pre-Fabwall - Providing And Fixing Of External Wall System On Light Gauge Steel Frame Work With Outer Face Cement Boards As Per Standard Sizes Fixed With Self- Drilling / Taping Screws / Fasteners @ 60Cm C / C Of Approved Make. , Pre-Fabin. Wall - Providing And Fixing Internal Wall Panels On Light Gauge Steel Frame Work With 12.5Mm Thick Gypsum Plaster Board Conforming Is 2095:2011 Fixed On Cement Board As Per Standard Sizes Fixed With Self-Drilling / Taping Screws / Fasteners @ 60Cm C / C Of Approved Make, Screws Shall Be Of Counter Sunk Rib Head Of 1.60Mm To 4 Mm Thick Or 8 To 10 Gauge Of Length Varying From 25 To 45 Mm. Proper Taping And Jointing To Be Done Using Fiber Mesh Tape And Epoxy And Acrylic Based Jointing Compound For Seamless Finish. ( Cost Of Frame Work To Be Paid For Separately , Roof Sheet - Supply & Installation Of Precoated Galvanised Iron Profile Sheets ( Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge ) 0.50 Mm + / - 5% Total Coated Thickness ( Tct ) Thick Zinc Coating 120Gsm As Per Is: 277 In 240Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches While Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling / Self Tapping Screws Of Size ( 5.5X 55Mm ) With Epdm Seal Or With Polymer Coated J Or L Hooks, Bolts And Nuts 8Mm Diameter With Bitumen And G.I. Limpet Washers Or With G.I. Limpet Washers Filled With White Lead Complete Upto Any Pitch In Horizontal / Vertical Or Curved Surfaces Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Ridge Plain - Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories 0.50 Mm + / - 5% Total Coated Thickness ( Tct ) Thick Zinc Coating 120Gsm As Per Is: 277 In 240Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling / Self Tapping Screws Or With Polymer Coated J Or L Hooks, Bolts And Nuts And Or G.I. Seam Bolts And Nuts, G.I. Plain And Bitumen Washers Complete : Ridges Plain ( 500 - 600Mm ) . , Gutter Drain - Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories 0.50 Mm + / - 5% Total Coated Thickness ( Tct ) Thick Zinc Coating 120Gsm As Per Is: 277 In 240Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling / Self Tapping Screws Or With Polymer Coated J Or L Hooks, Bolts And Nuts And Or G.I. Seam Bolts And Nuts, G.I. Plain And Bitumen Washers Complete : Gutter , Flashing - Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories 0.50 Mm + 5% Total Coated Thickness ( Tct ) , Zinc Coating 120Gsm As Per Is: 277 In 240Mpasteel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Topcoat 15-18 Microns Using Self Drilling / Self Tapping Screws Or With Polymer Coated J Or L Hooks, Bolts And Nuts And Or G.I. Seam Bolts And Nuts, G.I. Plain And Bitumenwashers Complete :Flashings / Aprons. ( Upto 600 Mm ) , Under Deck Insulation - Providing And Fixing Thermal Insulation Of Ceiling ( Under Deck Insulation ) With Resin Bonded Rockwool Conforming To Is: 8183, Density 48 Kg / M3, 50 Mm Thick, Wrapped In 200 G Virgin Polythene Bags Fixed To Ceiling With Metallic Cleats ( 50X50x3 Mm ) @ 60 Cm And Wire Mesh Of 12.5Mm X 24 Gauge Wire Mesh, For Top Most Ceiling Of Building. , Resin Bonded Rock Wool - Providing And Fixing Thermal Insulation With Resin Bonded Rock Wool Conforming To Is: 8183, Having Density 48 Kg / M3, 50 Mm Thick, Wrapped In 200 G Virgin Polythene Bags Fixed To Wall With Screw, Rawel Plug & Washers And Held And In Position By Criss Cossing Gi Wire Etc. Complete As Per Directions Of EngineerIn- Charge. , Face Panel - Providing And Fixing In All Exterior Face Panels Breathable Vapour Barrier Underneath The Cementfiber Board As Per National Building Code 2009 Complete As Per Direction Of Engineer-In-Charge. , Lap Siding - Supplying And Installation Of Moisture Resistant / Fire Resistantlap Siding 8 Mm Thick And Width As Per Standard Sizes Made Ofiber Cement Board With Embossed Decorative Finish To Give Pleasing Exterior Fixed Horizontally With Staggered Joints Including Minimum Over Lapof 32 Mm External Cement Fibre Boardconforming To Is 14862:2000 Offixed With Self-Drilling / Taping Screws / Fastners Of Approved Make. , Putty - Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Distemper - Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade : 1- New Work ( Two Or More Coats ) Over And Including Water Tinnable Priming Coat With Cement Primer , Ex. Paint - Finishing Walls With Textured Exterior Paint Of Required Shade : New Work ( Two Or More Coats Applied @ 3.28 Ltr / 10 Sqm ) Over And Including Priming Coat Of Exterior Primer Applied @ 2.20Kg / 10 Sqm Sqm , Oil Paint - Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work . , Steel-2 - Steel Work In Built Up Tubular ( Round, Square Or Rectangular Hollow Tubes Etc. ) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. Hot Finished Welded Type Tubes , Excavation - Earth Work In Excavation Over Areas ( Exceeding 30 Cm In Depth. 1.5 M In Width As Well Es 10 Sqm On Plan ) Including Disposal Of Excavated Earth , Lead Upto 50 M And Lift Upto 1.5 M; Disposed Earth To Be Levelled And Neatly Dressed. , Road - Providing And Laying C.C. Pavement Of Mix M-25 With Ready Mixed Concrete From Batching Plant. The Ready Mixed Concrete Shall Be Laid And Finished With Screed Board Vibrator , Vacuum Dewatering Process And Finally Finished By Floating, Brooming With Wire Brush Etc.Complete As Per Specifications And Directions Of Engineer-In- Charge. ( The Panel Shuttering Work Shall Be Paid For Separately ) . ( Note:- Cement Content Considered In This Item Is @ 330 Kg / Cum. Excess / Less Cement Used As Per Design Mix Is Payable / Recoverableseparately ) . , Paver Block - Providing And Laying 60 Mm Thick Factory Made Cement Concrete Interlocking Paver Block Of M -30 Grade Made By Block Making Machine With Strong Vibratory Compaction, Of Approved Size, Design & Shape, Laid In Required Colour And Pattern Over And Including 50 Mm Thickcompacted Bed Of Coarse Sand, Filling The Joints With Fine Sand Etc. All Complete As Per The Direction Of Engineer-In-Charge. , Phe 1 - Providing And Fixing Salem Stainless Steel A Isi 304 ( 18 / 8 ) Kitchen Sink As Per Is: 13983 With Ci Brackets And Stainless Steel Waste With Plug 40Mm Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required.Kitchen Sink With Drain Board 510X1040mm Bowl Depth 200Mm. , Phe 2 - Providing And Fixing Salem Stainless Steel A Isi 304 ( 18 / 8 ) Kitchen Sink As Per Is: 13983 With Ci Brackets And Stainless Steel Waste With Plug 40Mm Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required.Sink Without Drain Board 610X510 Mm Bowl Depth 200Mm. , Phe 3 - Providing And Fixing Mirror Of Superior Glass ( Of Approved Quality ) And Of Required Shape And Size With Plastic Moulded Frame Of Approved Make And Shade With 6 Mm Thick Hard Board Backing:Rectangular Shape 453X357 Mm , Phe 4 - Providing And Fixing Toilet Paper Holder:C.P. Brass , Phe 5 - Providing And Fixing Water Closet Squatting Pan ( Indian Type W.C.Pan ) With 100 Mm Sand Cast Iron P Or S Trap, 10 Litre Low Fixturescomplete, Including Cutting And Making Good The Walls Andlevel Whitep.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlleddevice ( Handle Lever ) Conforming To Is : 7231, With All Fittings Andfloors Wherever Required :White Vitreous China Orissa Pattern W.C. Pan Of Size580x440 Mm With Integral Type Foot Rests , Phe 6 - Providing And Fixing White Vitreous China Pedestal Type Water Closet ( European Type W.C. Pan ) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device ( Handle Lever ) , Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required : W.C. Pan With Isi Marked White Solid Plastic Seat And Lid , Phe 7 - Providing And Fixing 8 Mm Dia C.P. / S.S. Jet With Flexible Tube Upto 1 Metre Long With S.S. Triangular Plate To Eureopean Type W.C. Of Quality And Make As Approved By Engineer - In-Charge , Phe 8 - Providing And Fixing Cp Brass 32Mm Size Bottle Trap Of Approved Quality & Make And As Per The Direction Of Engineer-In-Charge.. ( Sink & Urinal ) , Phe 9 - Providing & Fixingptmt Towel Ring Trapezoidal Shape 215 Mm Long 200 Mm Wide With Minimum Distance Of 37 Mm From Wall Face With Concealedfittings Arrangement Of Approved Quality And Colour Weighing Not Less Than 88 Gms , Phe 10 - Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms.15Mm Nominal Bore , Phe 11 - Providing And Fixing C.P. Brass Bib Cock Of Approved Quality Confirming To Is:893115Mm Nominal Bore , Phe 12 - Providing And Fixing C.P.Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is 8931 A ) 15 Mm Nominal Bore.15 Mm Nominal Bore , Phe 13 - Providing And Fixing Wash Bashin With C.I. Brackets, 15Mm Dia Cp Brass Singal Hole Basin Mixer Of Approved Quility And Make, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required -White Vitreous China Surgeon Type Wash Basin Of Size660x460 Mm With A Pair Of 15 Mm C.P. Brass Pillar Tapswith Elbow Operated Levers , Phe 14 - Providing & Fixing Chrome Plated Brass Battery Based Infrared Sensor Operated Pillar Cock, Having Foam Flow Technology. , Phe 15 - Providing And Fixing White Vitreous China Laboratory Sink With C.I. Brackets, C.P. Brass Chain With Rubber Plug, 40 Mm C.P Brass Waste And 40Mm C.P. Brass Trap With Necessary C.P. Brass Unions Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Wall Wherever Required :Size 600X450x200 Mm , Phe 16 - Providing And Fixing Cp Brass Single Lever Telephonic Wall Mixer Of Quality & Make As Approved By Engineer In Charge . A ) 15 Mm Nominal Dia. , Phe 17 - Providing And Fixing Cp Brass Shower Rose With 15 Or 20 Mm Inlet100 Mm Diameter , Phe 18 - Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour.600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighing Not Less Than 190 Gms. , Phe 19 - Providing And Fixing Ptmt Liquid Soap Container 109 Mm Wide, 125 Mm High And 112 Mm Distance From Wall Of Standard Shape With Bracket Of The Same Materials With Snap Fittings Of Approved Quality And Colour, Weighing Not Less Than 105 Gms. , Phe 20 - Providing And Fixing G.I. Pipes Complete With Gi Fittings And Clamps Including Cutting And Making Good The Walls Etc. ( Internal Work ) 40 Mm Dia, Nominal Bore , Phe 21 - Providing And Fixing G.I. Pipes Complete With Gi Fittings And Clamps Including Cutting And Making Good The Walls Etc. ( Internal Work ) 50 Mm Dia, Nominal Bore , Phe 22 - Two Or More Coats On New Work Over An Under Coat Ofsuitable Shade With Ordinary Paint Of Approved Brand Andmanufacturetwo More Coast On New Work , Phe 23 - P / F M.S. Cap 100 Mm Dia , Phe 24 - Providing And Fixing, Upvcpipes 6 Kg / Cm2 ( Is: 4985 ) Including All Fittings ( Plain Or Door ) E.G. Bends, Junction, Offsets, Access Pieces, Jointing With Rubber Ring / Solvent Cement Joints Includingrequired Suports, Cutting Chase Or Holes In Walls And Floors And Making Good Where Required.75 Mm Dia Pipe , Phe 25 - Providing And Fixing, Upvcpipes 6 Kg / Cm2 ( Is: 4985 ) Including All Fittings ( Plain Or Door ) E.G. Bends, Junction, Offsets, Access Pieces, Jointing With Rubber Ring / Solvent Cement Joints Includingrequired Suports, Cutting Chase Or Holes In Walls And Floors And Making Good Where Required.110 Mm Dia Pipe , Phe 26 - Providing & Fixing On Wall Face Unplasticised -Rigid Pvc Rain Water Pipes Conforming To Is:13592 Tyape A Included Jointing With Seal Ring Conforning To Is:5382 Leaving 10 Mm Gap For Thermal Expansion. ( I ) Single Socketed Pipes.110 Mm Diameter , Phe 27 - Providing, Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised - Rigid Pvc Rain Water Pipes Conforming To Is ; 13592 Type A Including Jointing With Seal Ring Conforming To Is ; 5382 Leaving 10 Mm Gap For Thermal Expansion. Coupler -110 Mm Diameter , Phe 28 - Providing, Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised - Rigid Pvc Rain Water Pipes Conforming To Is ; 13592 Type A Including Jointing With Seal Ring Conforming To Is ; 5382 Leaving 10 Mm Gap For Thermal Expansion. Bend -87.5 Deg -110 Mm Diameter , Phe 29 - Providing, Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised - Rigid Pvc Rain Water Pipes Conforming To Is ; 13592 Type A Including Jointing With Seal Ring Conforming To Is ; 5382 Leaving 10 Mm Gap For Thermal Expansion. Shoe -110Mm Shoe , Phe 30 - Providing & Fixing Unplasticised - Pvc Pipe Clips Of Approved Design To Unplasticised - Pvc Rain Water Pipes By Means Of 50X50x50mm Hard Wood Plugs, Screwed With .M.S. Screws Of Required Length Including Cutting Brick Work And Fixing In Cement Mortar 1:4 ( 1Cement : 4 Coarse Sand ) And Making Good The Wall Etc. Complete.110 Mm Dia , Phe 31 - Providing And Fixing Cpvc Pipes Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipe With Clamps At 1.00 Mt Spacing. This Includes Jionting Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge. 20 Mm Nominal Outer Dia Pipes , Phe 32 - Providing And Fixing Of Gun Metal Gate Valve With Ci Wheel Of Approved Quality ( Screwed Ends ) 25Mm Dia, Nominal Bore , Phe 33 - Providing And Fixing Of Gun Metal Gate Valve With Ci Wheel Of Approved Quality ( Screwed Ends ) 32 Mm Dia, Nominal Bore , Phe 34 - Providing And Fixing Gun Metal Non- Return Valve Of Approved Quality ( Pn 1.6 ) 40 Nominal Bore , Phe 35 - Providing And Fixing Brass Stop Cock Of Approved Quality15mm Nominal Bore , Phe 36 - Butterfly Valve ( Manual ) With C I Body Ss Disc, Nitrile Rubber Seal & O- Ring Pn 16 Pressure Rating For Chilled Water / Hot Eater Circulation As Specified 65 Nominal Bore , Phe 37 - Butterfly Valve ( Manual ) With C I Body Ss Disc, Nitrile Rubber Seal & O- Ring Pn 16 Pressure Rating For Chilled Water / Hot Eater Circulation As Specified80 Nominal Bore , Phe 38 - Providing And Fixing Ball Valve ( Brass ) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete25 Mm Nominal Bore , Ex. Phe 1 - Providing And Fixing C.I. Double Acting Air Valve Of Approved Quality With Bolts, Nuts, Rubber Insertions Etc. Complete ( The Tail Pieces, Tapers Etc If Required Will Be Paid Separately ) :50 Mm Dia , Ex. Phe 2 - Providing And Fixing C.I. Double Acting Air Valve Of Approved Quality With Bolts, Nuts, Rubber Insertions Etc. Complete ( The Tail Pieces, Tapers Etc If Required Will Be Paid Separately ) :80 Mm Dia , Ex. Phe 3 - Providing And Fixing C.I. Double Acting Air Valve Of Approved Quality With Bolts, Nuts, Rubber Insertions Etc. Complete ( The Tail Pieces, Tapers Etc If Required Will Be Paid Separately ) :100 Mm Dia , Ex. Phe 4 - Providing & Fixing C.I.Sluice Valve ( With Cap ) Complete With Bolts, Nuts, Rubber Insertions Etc. ( The Tail Pieces If Required Will Be Paid Separately ) 100 Mm Dia.Pipe , Ex. Phe 5 - Providing & Fixing C.I.Sluice Valve ( With Cap ) Complete With Bolts, Nuts, Rubber Insertions Etc. ( The Tail Pieces If Required Will Be Paid Separately ) 150 Mm Dia.Pipe , Ex. Phe 6 - Providing 250Mm Wide Brick Drain In Cement Mortar ( 1:6 ) With Av. 150Mm.Clear Depth And 250Mm Apron Including Cost Of E / W. Involved With 75Mmcement Concrete ( 1:4:8 ) Over One Brick Designation 100-A Flat Soling Inproper Grade And Slope At The Base.The Drain Duly.Plastered In Cm. ( 1:3 ) With Punning Over Exposed Surface All Complete As Per Buildingspecification And Direction Of E / L, , Ex. Phe 7 - Excavating Trenches Of Required Width For Pipes, Cables Etc. Including Excavation For Sockets And Dressing Of Sides, Ramming Of Bottom Depth Upto 1.5 M Including Getting Out The Excavated Soil ( Hard Or Soft ) And Then Returning The Soil As Required In Layers Not Exceeding 20 Cms In Depth Including Consolidating Each Deposited Layer By Ramming, Watering Etc. And Disposing Of Surplus Excavated Soil As Directed Within A Lead Of 50M. [ Hard / Dense Soil ] Pipes, Cables Etc.Exceeding 80Mm Dia.But Not Exceeding 300Mm Dia. , Ex. Phe 8 - Excavating Trenches Of Required Width For Pipes, Cables Etc. Including Excavation For Sockets And Dressing Of Sides, Ramming Of Bottom Depth Upto 1.5 M Including Getting Out The Excavated Soil ( Hard Or Soft ) And Then Returning The Soil As Required In Layers Not Exceeding 20 Cms In Depth Including Consolidating Each Deposited Layer By Ramming, Watering Etc. And Disposing Of Surplus Excavated Soil As Directed Within A Lead Of 50M. [ Hard / Dense Soil ] Pipes, Cables Etc.Exceeding 80Mm Dia. Exceeding 300Mm Dia. , Ex. Phe 9 - Providing And Laying Non-Pressure Np2 Class ( Light Duty ) Rcc Pipes With Collars Jointed With Stiff Mixture Of Cement Mortar In The Proportion Of 1:2 ( 1 Cement : 2 Fine Sand ) Including Testing Of Joints Etc. Complete. ( For Storm Drainage ) 250 Mm Dia Rcc Pipe , Ex. Phe 10 - Providing And Laying Non-Pressure Np2 Class ( Light Duty ) Rcc Pipes With Collars Jointed With Stiff Mixture Of Cement Mortar In The Proportion Of 1:2 ( 1 Cement : 2 Fine Sand ) Including Testing Of Joints Etc. Complete. ( For Storm Drainage ) 300 Mm Dia Rcc Pipe , Ex. Phe 11 - Providing And Laying Non-Pressure Np2 Class ( Light Duty ) Rcc Pipes With Collars Jointed With Stiff Mixture Of Cement Mortar In The Proportion Of 1:2 ( 1 Cement : 2 Fine Sand ) Including Testing Of Joints Etc. Complete. ( For Storm Drainage ) 450 Mm Dia Rcc Pipe , Ex. Phe 12 - Inside Size 120X90 Cm And 90 Cm Deep Including C.I. Cover With Frame ( Medium Duty ) 500 Mm Internal Diameter, Total Weight Of Cover And Frame To Be Not Less Than 116 Kg ( Weight Of Cover 58 Kg And Weight Of Frame 58 Kg ) :With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 , Ex. Phe 13 - Providing And Fixing Square Mouth Sw Gully Trap Grade ‘A’ Complete Ci Grating Brick Masonry Chamber With Bricks Of Class Designation 75 And Water Tight Ci Cover With Frame Of 300 X 300 Mm Size ( Inside ) The Weight Of Cover To Be Not Less Than 13.00 Kg And Frame To Be Not Less Than 5 Kg. As Per Standard Design. ( Cover Min. 4.5 Kg & Frame Min.2.7 Kg ) 180X150 Mm Size P Type With Fps Bricks , Ex. Phe 14 - Constructing Masonry Chamber 30X30x50 Cm, Inside With 75 Class Designation Brick Work In Cement Mortar 1:4 ( 1 Cement:4 Coarce Sand ) For Stop Cock Complete With C.I. Surface Box 100X100x75mm ( Inside ) With Locking Arrangement And Rcc Top Slab 1:2:4 Mix ( 1 Cement : 2 Corase Sand: 4 Graded Stonr Aggregate 20Mm Nominal Size ) Necessary Excavation Foundation Concret 1:5:10 ( 1 Cement:5 Fine Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size ) And Inside Plastering With Cement Mortor 1:3 ( 1 Cement : 3 Coarse Sand ) 12 Mm Thick Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design. , Ex. Phe 15 - Constructing Masonry Chamber 60X60x75 Cm, Inside With 75 Class Designation Brick Work In Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) For Sluice Valve, With C.I. Surface Box 100 Mm Top Diameter, 160 Mm Bottom Diameter And 180 Mm Deep ( Inside ) With Channel Lid And Rcc Top Slab 1:2:4 Mix ( 1 Cement: 2 Coarse Sand: 4 Graded Stone Sggregate 20 Mm Nominal Size ) Necessary Excavation Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) 12 Mm Thick Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design:With F.P.S. Bricks , Ex. Phe 16 - Structual Steel Work Welded In Built Up Sections, Trusses And Framed Work Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. , Ex. Phe 17 - Making Connection Of Gi Distribution Branch With Gi Main Of 50-80Mm Nominal Bore By Providing And Fixing Tee, Including Cutting And Threading The Pipe Etc. Complete. , Rain Water Harvesting 1 - Boring / Drilling Bore Well Of Required Dia For Casing / Strainer Pipe, Bysuitable Method Prescribed In Is:2800 ( Part I ) , Including Collecting Sample From Different Strata , Preparing And Submitting Strata Chart / Bore Log, Including Hire & Running Charges Of All Equipments, Tools, Plants & Machineries Required For The Job, All Complete As Per Direction Of Engineer-In-Charge, Upto 90M Depth Below Ground Level.300 Mm Dia , Rain Water Harvesting 2 - Supplying, Assembling, Lowering And Fixing In Vertical Position In Bore Well, Unplasticized Plc. Medium Well Casing ( Cm ) Pipe Of Required Dia, Conforming To Is: 12818, Including Required Hire & Labour Charges, Fittings & Accessories, All Complete, For All Depths, As Per Director Of Engineer-In-Charge.150Mm Nominal Size Dia , Rain Water Harvesting 3 - Supplying, Assembling, Lowering And Fixing In Vertical Position In Bore Well, Unplasticized Plc. Medium Well Screen ( Rms ) Pipes With Ribs, Conforming To Is: 12818, Including Required Hire & Labour Charges, Fittings & Accessories, All Complete, For All Depths, As Per Director Of Engineer-In-Charge.150 Mm Nominal Size Dia , Rain Water Harvesting 4 - Supplying, Filling, Spreading & Levelling Stone Boulders Of Size Range 5Cm To 20Cm, In Recharge Pit, In The Required Thickness, For All Leads & Lifts, All Complete As Per Direction Of Engineer-In-Charge. , Rain Water Harvesting 5 - Supplying, Filling, Spreading & Levelling Gravel Of Size Range 5Mm To 10Mm, In Recharge Pit, Over The Existing Layer Of Boulders, In Required Thickness, For All Leads & Lifts, All Complete As Per Direction Of Engineer-In-Charge. , Rain Water Harvesting 6 - Supplying, Filling, Spreading & Levelling Coarse Sand Of Size Range 1.5Mm To 2Mm, In Recharge Pit, In Required Thickness Over Gravel Layer, For All Leads & Lifts, All Complete As Per Direction Of Engineer-In-Charge. , Rain Water Harvesting 7 - Providing And Fixing Bail Plug / Bottom Plug Of Required Dia To The Bottom Of Pipe Assembly Of Tube Well As Per Is:2800 ( Part I ) . 100 Mm Dia , Rain Water Harvesting 8 - Making Soak Pit 2.5 M Diameter 3.0 Metre Deep With 45 X 45 Cm Dry Brick Honey Comb Shaft With Bricks And S.W. Drain Pipe 100 Mm Diameter, 1.8 M Long Complete As Per Standard Design. With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 , Rain Water Harvesting 9 - Constructing Soak Pit 1.20X1.20X1.20 M Filled With Brickbats Including S.W. Drain Pipe 100 Mm Diameter And 1.20 M Long Complete As Per Standard Design. With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 , Tubewell 1 - Boring / Drilling Bore Well Of Required Dia For Casing / Strainer Pipe, Bysuitable Method Prescribed In Is:2800 ( Part I ) , Including Collecting Sample From Different Strata , Preparing And Submitting Strata Chart / Bore Log, Including Hire & Running Charges Of All Equipments, Tools, Plants & Machineries Required For The Job, All Complete As Per Direction Of Engineer-In-Charge, Upto 90M Depth Below Ground Level.300 Mm Dia , Tubewell 2 - Supplying, Assembling, Lowering And Fixing In Vertical Position In Bore Well, Unplasticized Plc. Medium Well Casing ( Cm ) Pipe Of Required Dia, Conforming To Is: 12818, Including Required Hire & Labour Charges, Fittings & Accessories, All Complete, For All Depths, As Per Director Of Engineer-In-Charge.150Mm Nominal Size Dia , Tubewell 3 - Supplying, Assembling, Lowering And Fixing In Vertical Position In Bore Well, Unplasticized Plc. Medium Well Casing ( Cm ) Pipe Of Required Dia, Conforming To Is: 12818, Including Required Hire & Labour Charges, Fittings & Accessories, All Complete, For All Depths, As Per Director Of Engineer-In-Charge.100Mm Nominal Size Dia , Tubewell 4 - Supplying, Assembling, Lowering And Fixing In Vertical Position In Bore Well, Unplasticized Plc. Medium Well Screen ( Rms ) Pipes With Ribs, Conforming To Is: 12818, Including Required Hire & Labour Charges, Fittings & Accessories, All Complete, For All Depths, As Per Director Of Engineer-In-Charge.100 Mm Nominal Size Dia , Tubewell 5 - Supplying, Filling, Spreading & Levelling Stone Boulders Of Size Range 5Cm To 20Cm, In Recharge Pit, In The Required Thickness, For All Leads & Lifts, All Complete As Per Direction Of Engineer-In-Charge. , Tubewell 6 - Providing And Fixing Bail Plug / Bottom Plug Of Required Dia To The Bottom Of Pipe Assembly Of Tube Well As Per Is:2800 ( Part I ) . 100 Mm Dia , Submersible Pump - 35M Deep Boring With Casing And Pipe. Supply Of Pipe Etc Supplying & Installation Of Suitable 2Hp Submersible Pump B.S Or K.S.Bor Equivalent Make With Finolex Cable 1X3x2.5 Squmm ( Upto 50Mtr ) Withflexible Conduit 25Mm Dia, Electrical Out Door Pannel With Required Electrical Fitting Such As Mcb Of 0-25Amp ( Havell Or Indocopp Or Mds Make ) , Volt & Ampere Meter ( Ae Make ) , Single Phase Preventer ( Minilac Or Vsp -1 Make ) Starter ( L&T Or Bch Make ) Etc Of Approved Make, 40Mm Hdpe Pipe ( 25 Mtr ) And All Accessories Complete As Per Requirement Of Site. , Water Purifier And Cooler 1 - Fitting And Fixing Single Faucet Storage Type Water Cooler ( Size 461 Mm Wide X 582 Mm Deep X 1217 Mm Height, Weight 46 Kg ) Fully Stainless Body Having Storage Capacity Of 40 Ltrs, Cooling Capacity Of 40 Ltrs. / Hr. With Hermetic Type Compressor, Gas Cooled Motor Equipped With Over Load Protector, Condensor For Propeller Type, Thermostat Autometically Controlled Temperature, Refrigerent R -22, 230 Volt, Single Phase 50 Hertz, Maximum Current 2.3 Amp Including Plug Top And Electrical Lead Wire Connection Upto 3 Metres From The Cooler, Water Inlet And Drain Out Connections Complete In All Respects Of Voltas Model No 40 / 40 Tushar Pss Type Or Similar Type Of Approved Make. , Water Purifier And Cooler 2 - Fitting And Fixing Water Purifier For Drinking Purpose Of Capacity 6 Litres / Min, 5 Purification System With Reverse Osmosis System With Ultra Ventilated Membrane, Tds500 To 2000 Mgl / Ppm, Auto Shut Off With Microswitch Float Manual Flush Facility, Tds Reduction 90% Having Automatic Backwash System With Filteration Unit Along With All Accessories Including Plug Top And Electrical Lead Wire Connection Upto 3 Metres From The Purifier, Water Inlet And Drain Out Connections Complete In All Respects Similar To Aquaguard Or Similar Approved Make - ( Model - Aquasure Elegant Ro Water Purifier Of Size Width 360 Mm X Height - 430 Mm X Depth 235 Mm And Weight 8.5 Kg ) . , Fire Extinguisher-1 - Providing And Fixing Carbon-Di-Oxide Type Fire Extinguishers Consisting Of Welded M.S. Cylindericalbody, Squeeze Lever Discharge Valve Fitted With Pressure Indicating Guage Internal Discharge Tube 30 Cms Long High Pressure Discharge Hose, Discharge Nozzle, Suspension Bracket Conforming To Is:15683 Finished Externally With Red Enamel Paint And Fixed To Wall With Brackets Complete With Internal Charge. Capacity 4.5 Kg. , Fire Extinguisher-2 - Providing And Fixing Abc Powder Type Fire Extinguishers Consisting Of Welded M.S. Cylindericalbody, Squeeze Lever Discharge Valve Fitted With Pressure Indicating Guage Internal Discharge Tube 30 Cms Long High Pressure Discharge Hose, Discharge Nozzle, Suspension Bracket Conforming To Is:15683 Finished Externally With Red Enamel Paint And Fixed To Wall With Brackets Complete With Internal Charge.Capacity 6.0 Kg. , Electrical 1 - Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bellpoint With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductorsingle Core Cable In Surface / Recessed Steel Conduit, Withmodular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. Group C , Electrical 2 - Wiring For Twin Control Light Point With 1.5 Sq.Mm Frls Pvcinsulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, 2 Way Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Electrical 3 - Wiring For Group Controlled ( Looped ) Light Point / Fan Point / Exhaust Fan Point / Call Bell Point ( Without Independent Switch Etc. ) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulatedcopper Conductor Single Core Cable Etc. As Required. Group C , Pvc Conduit 1 - Supplying And Fixing Of Following Sizes Of Medium Class 20Mmpvc Conduit Along With Accessories In Surface / Recessincluding Cutting The Wall And Making Good The Same Incase Of Recessed Conduit As Required. , Pvc Conduit 2 - Supplying And Fixing Of Following Sizes Of Medium Class 32Mmpvc Conduit Along With Accessories In Surface / Recessincluding Cutting The Wall And Making Good The Same Incase Of Recessed Conduit As Required. , Pvc Conduit 3 - Supplying And Fixing Of Following Sizes Of Medium Class 50Mmpvc Conduit Along With Accessories In Surface / Recessincluding Cutting The Wall And Making Good The Same Incase Of Recessed Conduit As Required. , Electrical 4 - Wiring For Light / Power Plug With 2X4 Sq. Mm Frls Pvcinsulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit Alongwith 1 No. 4 Sq. Mm Frls Pvcinsulated Copper Conductor Single Core Cable For Loop Earthingas Required. , Wiring Frls Pvc Insulated Copper Conductor 1 - 2 X 2.5 Sq. Mm. + 1 X 2.5 Sq. Mm. Earth Wire , Wiring Frls Pvc Insulated Copper Conductor 2 - 2 X 4 Sq.Mm. + 1 X 4 Sq.Mm. Earth Wire , Wiring Frls Pvc Insulated Copper Conductor 3 - 2 X 6 Sq.Mm. + 1 X 6 Sq.Mm. Earth Wire , Wiring Frls Pvc Insulated Copper Conductor 4 - 4 X 6 Sq. Mm + 2 X 6 Sq. Mm Earth Wire , Wiring Frls Pvc Insulated Copper Conductor 5 - 4 X 10 Sq. Mm + 2 X 6 Sq. Mm Earth Wire , Wiring Frls Pvc Insulated Copper Conductor 6 - 4 X 16 Sq. Mm + 2 X 16 Sq. Mm Earth Wire , S / F, Gi Box Along With Modular Base & Cover Plate 1 - 1 Or 2 Module ( 75Mm X 75Mm ) , S / F, Gi Box Along With Modular Base & Cover Plate 2 - 3 Module ( 100Mm X 75Mm ) , S / F, Gi Box Along With Modular Base & Cover Plate 3 - 4 Module ( 125Mmx75mm ) , S / F, Gi Box Along With Modular Base & Cover Plate 4 - 6 Module ( 200Mm X 75Mm ) , S / F, Gi Box Along With Modular Base & Cover Plate 5 - 12 Module ( 200Mmx150mm ) , S / F Modular Switch / Socket On The Existing Modular Plate 1 - 5 / 6 Amps Switch , S / F Modular Switch / Socket On The Existing Modular Plate 2 - 15 / 16 Amp Switch , S / F Modular Switch / Socket On The Existing Modular Plate 3 - 3 Pin 5 / 6 Amp Socket Outlet , S / F Modular Switch / Socket On The Existing Modular Plate 4 - 6 Pin 15 / 16 Amp Socket Outlet , S / F Modular Switch / Socket On The Existing Modular Plate 5 - Telephone Socket Outlet , S / F Modular Switch / Socket On The Existing Modular Plate 6 - Tv Antenna Socket Outlet , S / F Modular Switch / Socket On The Existing Modular Plate 7 - Bell Push , Fan Regulator On The Existing Modular Plate Switch Box - Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. , Call Bell / Buzze - Supplying And Fixing Call Bell / Buzzer Suitable For Single Phase, 230 Volts, Complete As Required. , Electrical 5 - Supplying & Fixing Suitable Size Gi Box Wih Modular Plate And Cover In Front On Surface Or In Recess Including Providing And Fixing 25 A Modular Socket Outlet And 25 A Modular Sp Mcb, “C” Curve Including Connections, Painting Etc. As Required. ( For Ac / Geyser ) , Electrical 6 - Supplying And Drawing Co-Axial Tv Cable Rg-6 Grade, 0.7 Mm Solid Copper Conductor Pe Insulated, Shielded With Fine Tinned Copper Braid And Protected With Pvc Sheath In The Existing Surface / Recessed Steel / Pvc Conduit As Required. , Electrical 7 - Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. , Electrical 8 - Providing And Fixing M.S. Fan Clamp Type I Or Ii Of 16 Mm Dia M.S. Bar, Bent To Shape With Hooked Ends In R.C.C. Slabs Or Beams During Laying, Including Painting The Exposed Portion Of Loop, All As Per Standard Design Complete As Required. , Electrical 9 - Providing And Fixing Circular / Hexagonal Cast Iron Or M.S. Sheet Box For Ceiling Fan Clamp, Of Internal Dia 140 Mm, 73 Mm Height, Top Lid Of 1.5 Mm Thick M.S. Sheet With Its Top Surface Hacked For Proper Bonding, Top Lid Shall Be Screwed Into The Cast Iron / M.S. Sheet Box By Means Of 3.3 Mm Dia Round Headed Screws, One Lock At The Corners. Clamp Shall Be Made Of 12 Mm Dia M.S. Bar Bent To Shape As Per Standard Drawing. , 40A Fp-Isolator - Supplying And Fixing Following Rating, Four Pole, 415 V, Isolator In The Existing Mcb Db Complete With Connections, Testing Andcommissioning Etc. As Required. , Electrical 10 - Supplying And Fixing 20 A, 240 V, Spn Industrial Type Socket Outlet, With 2 Pole And Earth, Metal Enclosed Plug Top Alongwith 20 A C Curve, Sp, Mcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Outlet And Complete With Connections, Testing And Commissioning Etc. As Required. , Electrical 11 - Supplying And Fixing 20 A, 415 V, Tpn Industrial Type Socket Outlet, With 4 Pole And Earth, Metal Enclosed Plug Top Alongwith 20 A C Curve, Tpmcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Out Let And Complete With Connections, Testing And Commissioningetc. As Required. , Electrical 12 - Supplying And Fixing 30 A, 415 V, Tpn Industrial Type Socket Outlet, With 4 Pole And Earth, Metal Enclosed Plug Top Alongwith 30 A C Curve, Tpmcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Out Let And Complete With Connections, Testing And Commissioningetc. As Required. , Electrical 17 - Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 8 Way ( 4 + 24 ) , Double Door , Electrical 18 - Supplying And Fixing Of Following Ways Surface / Recess Mounting, Vertical Type, 415 V, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 A Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs ( But Without Mcbs And Incomer ) As Required . ( Note : Vertical Type Mcb Tpdb Is Normally Usedwhere 3 Phase Outlets Are Required. ) 4 Way ( 4 + 12 ) , Double Door , Electrical 19 - Supplying And Fixing Of Following Ways Surface / Recess Mounting, Vertical Type, 415 V, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 A Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs ( But Without Mcbs And Incomer ) As Required . ( Note : Vertical Type Mcb Tpdb Is Normally Usedwhere 3 Phase Outlets Are Required. ) 8 Way ( 4 + 24 ) , Double Door , Electrical 20 - Supplying And Fixing Cable End Box ( Loose Wire Box ) Suitable For Following Triple Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 Volts, On Surface / Recess, Complete With Testing And Commissioning Etc.As Required. For 8 Way, Double Door Fp Mcbdb , Electrical 21 - Supplying And Fixing Cable End Box ( Loose Wire Box ) Suitable For Triple Pole And Neutral, Sheet Steel, Vertical Mcb Distribution Board, 415 V, On Surface / Recess, Complete With Testing And Commissioning Etc. As Required. , 25 A, Rccb - Supplying And Fixing Following Rating, Double Pole, ( Single Phase And Neutral ) , 240 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. , 40 A, Rccb - Supplying And Fixing Following Rating, Double Pole, ( Single Phase And Neutral ) , 240 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. , Single Pole Mcb - Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. , Triple Pole Mcb - Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. , 40A Tp Mcb - Supplying And Fixing 40 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40A Tp Mcb , 40A 4P Mcb - Supplying And Fixing Of Following Mcbs, 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Offollowing Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40A Fp Mcb , 63A 4P Mcb - Supplying And Fixing Of Following Mcbs, 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Offollowing Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. , 100A 4P Mcb - Supplying And Fixing Of Following Mcbs, 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Offollowing Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. , L / F Pvc Sheathed / Xlpe Power Cable In Trench 1 - Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size Direct In Ground Including Excavation, Sand Cushioning, Protective Covering And Refilling The Trench Etc As Required. Above 95 Sq. Mm And Upto 185 Sq. Mm , L / F Pvc Sheathed / Xlpe Power Cable In Trench 2 - Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size Direct In Ground Including Excavation, Sand Cushioning, Protective Covering And Refilling The Trench Etc As Required. Above 185 Sq. Mm And Upto 400 Sq. Mm , L / F Pvc Sheathed / Xlpe Power Cable Over Cable Tray - Above 35 Sq. Mm And Upto 95 Sq. Mm ( Clamped With 25X3mm Ms Flat Clamp ) , S / M End Termination With Brass Compression Gland And Aluminium Lugs Aluminium Conductor Cable Of 1.1 Kv Grade 1 - 3.5C X 185 Sqmm, Aluminium Conductor Cable A2xfy , S / M End Termination With Brass Compression Gland And Aluminium Lugs Aluminium Conductor Cable Of 1.1 Kv Grade 2 - 3.5C X 150 Sqmm, Aluminium Conductor Cable A2xfy , S / M End Termination With Brass Compression Gland And Aluminium Lugs Aluminium Conductor Cable Of 1.1 Kv Grade 3 - 4C X 35 Sqmm Aluminium Conductor Cable A2xfy , Cable Tray 1 - Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray ( Galvanisation Thickness Not Less Than 50 Microns ) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc. As Required. 100 Mm Width X 50 Mm Depth X 1.6 Mm Thickness , Cable Tray 2 - Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray ( Galvanisation Thickness Not Less Than 50 Microns ) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc. As Required. 300 Mm Width X 50 Mm Depth X 1.6 Mm Thickness , Cable Tray 3 - Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray ( Galvanisation Thickness Not Less Than 50 Microns ) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc. As Required. 600 Mm Width X 62.5 Mm Depth X 2.0 Mm Thickness , Cable Tray “Bends” 1 - Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray “Bends” ( Galvanisation Not Less Than 50 Microns ) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc. As Required.100 Mm Width X 50 Mm Depth X 1.6 Mm Thickness , Cable Tray “Bends” 2 - Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray “Bends” ( Galvanisation Not Less Than 50 Microns ) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc. As Required.300 Mm Width X 50 Mm Depth X 1.6 Mm Thickness , Cable Tray “Bends” 3 - Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray “Bends” ( Galvanisation Not Less Than 50 Microns ) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc. As Required.600 Mm Width X 62.5 Mm Depth X 2.0 Mm Thickness , Mv Cable 1 - Supplying Following 1.1Kv Grade, Xlpe Insulated, Frls Type, Heavy Duty Armoured Cables Suitable For 415V, 50Hz, Ac System, With Inner And Outer Pvc Sheath, Outer Sheath Provided With Frls Insulation, Galvanised Steel Armouring ( Round ( W ) Or Flat ( F ) As Mentioned ) And With All Components As Mentioned , Specifications, Complete As Required.3.5C X 185 Sqmm, Aluminium Conductor Cable A2xfy , Mv Cable 2 - Supplying Following 1.1Kv Grade, Xlpe Insulated, Frls Type, Heavy Duty Armoured Cables Suitable For 415V, 50Hz, Ac System, With Inner And Outer Pvc Sheath, Outer Sheath Provided With Frls Insulation, Galvanised Steel Armouring ( Round ( W ) Or Flat ( F ) As Mentioned ) And With All Components As Mentioned , Specifications, Complete As Required.3.5C X 150 Sqmm, Aluminium Conductor Cable A2xfy , Mv Cable 3 - Supplying Following 1.1Kv Grade, Xlpe Insulated, Frls Type, Heavy Duty Armoured Cables Suitable For 415V, 50Hz, Ac System, With Inner And Outer Pvc Sheath, Outer Sheath Provided With Frls Insulation, Galvanised Steel Armouring ( Round ( W ) Or Flat ( F ) As Mentioned ) And With All Components As Mentioned , Specifications, Complete As Required. 4C X 35 Sqmm Aluminium Conductor Cable A2xfy , Earthing 1 - Earthing With G.I. Earth Pipe 4.5 Metre Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal / Coke And Salt As Required. , Earthing 2 - Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal / Coke And Salt As Required. , Earthing 3 - Earthing With Copper Earth Plate 600 Mm X 600 Mm X 3 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal / Coke And Salt As Required. , Earthing 4 - Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface / Recessed Conduit / Submain Wiring / Cable As Required. , Earthing 5 - Providing And Fixing 25 Mm X 5 Mm G.I. Strip On Surface Or In Recess For Connections Etc. As Required. , Earthing 6 - Providing And Fixing 25 Mm X 5 Mm Copper Strip On Surface Or In Recess For Connections Etc. As Required. , Earthing 7 - Providing And Fixing 25 Mm X 5 Mm G.I. Strip In 40 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Nut, Bolt, Spring, Washer Excavation And Re-Filling Etc. As Required. , Earthing 8 - Providing And Fixing 25 Mm X 5 Mm Copper Strip In 40 Mm Dia G.I. Pipe From Earth Electrode Including Connection With Brass Nut, Bolt, Spring, Washer Excavation And Re-Filling Etc. As Required. , Earthing 9 - Providing And Fixing Earth Bus Of 50 Mm X 5 Mm Copper Strip On Surface For Connections Etc. As Required. , Earthing 10 - Providing And Fixing Earth Bus Of 50 Mm X 5 Mm Gi Strip On Surface For Connections Etc. As Required. , Fiting & Fixtures 1 - Supply And Installation Of Regular / Standard Model A.C. Ceiling Fan Of 1400 Mm Sweep Including Wiring The Down Rods Of Standard Length ( Upto 30 Cm ) With 1.5 Sq. Mm Fr Pvc Insulated Copper Conductor Etc As Required. , Fiting & Fixtures 2 - Supplying And Fixing Single Wall Mounted 18 / 22 Watt Led Type Batten Fitting Complete With Electronic Driver And Led Tube Etc Directly On Wall / Ceiling Includingconnections With 1.5 Sq.Mm Fr Pvc Insulated Copper Conductor And Earthing The Body Etc. As Required. , Fiting & Fixtures 3 - Supply Installation And Comissioning Ofintegrated Batten Made ( 2Ft ) Of Ultra Slim Co-Extruded Polycarbonate Channel With Housing Part In White Finish & Diffuser Part In Reeded Opal Finish.White Finish Abs End Caps With Decorative Circular Coloured Polycarbonate Cap Snap Fitted On The End Cap To Enhance The Aesthetic Of The Fixture. These End Caps Are Snap-Fitted To The Fixture.High Efficiency Long Life Led With Lumen Efficacy Of 130 Lm / W With Viewing Angle Of 120º.Powered By An Integral Isolated Low Thd Electronic Led Driver ( Smps Based Constant Current Supply ) With Output Short Circuit Protection, Surge Protection.Can Be Fixed Directly Into The Wall / Ceiling , Fiting & Fixtures 4 - Supplying And Fixing Recess Mounted 12 Watt Led Vertical Downlighter Complete With All Accessories And Replaceable Electronic Driver, Directly On False Ceilingincluding Connection With 1.5 Sq.Mm Fr Pvc Insulated Copper Conductor Cable And Earthing The Body Etc. As Required. , Fiting & Fixtures 5 - Supplying And Fixing Recess Mounted 18 Watt Led Vertical Downlighter Complete With All Accessories And Replaceable Electronic Driver, Directly On False Ceilingincluding Connection With 1.5 Sq.Mm Fr Pvc Insulated Copper Conductor Cable And Earthing The Body Etc. As Required. , Fiting & Fixtures 6 - Supply, Installation, Testing And Commissioning Of 400 Mm Sweep, 65W, Blade Material Aluminium Blades , Speed & Oscillation 3 Speed, Pull Cord For Speed And Oscillation.Air Delivery Minimum 72 M³ / Min, Speed Minimun 1350 Revolution Per Minute.Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc. Complete As Required. , Fiting & Fixtures 7 - Supply Installation And Comissioning Of 28W 2X2 Panel Recess Mounting Luminaire With High Performance Leds, Suitable For Mounting With Armstrong / Grid Ceiling.Crca Powder Coated White After Phosphochromate Treatment.High Efficiency Long Life Led Package In Integral Module With Lumen Efficacy Of >100 Lm / W And Viewing Angle Of 120° To Ensure Better Uniformity.Powered By An Independent Isolated, Selv Output Electronic Led Driver ( Smps Based Constant Current Supply ) With Output Short-Circuit Protection, Surge Protection & Other Reliability Test. , Fiting & Fixtures 8 - Supplying Installation Testing & Commissioning Ofb22 Based 9W Led 3 Star Bulb With 850 Lumen, 6K Color Temperature Including Holder. , Fiting & Fixtures 9 - Supplying Installation Testing & Commissioning Of Black Painted Extruded Aluminium Housing. Green / Red Led’S Mounted Inside The Housing. Laser Engraved Signage Matter On Single / Double Acrylic Sheet Fixed On One Side Suitable For Wall / Ceiling / Suspension Type Single / Double Sided Display. In Double Sided Version Black Paper Is Inserted. Ni-Cd Battery Back Up To 2 Hrs. ( Charged Up To 8 - 10 Hrs ) .Mounting Strings Provided For Pendent Mounting Operating Voltage 150-280V Ac Ambient Operating Temperature. – 0 To 450C Ingress Protection – Ip42.Including 3 Core 1.5 Sq.Mm Frls Pvc Insulated And Pvc Sheathed Copper Conductor Cable And Earthing Etc. Up To Suitable Point Complete As Required.220208 Besl 03 Led Ssd Wbb Green 240 3 8Wor220209 Besl 03 Led Ssd Wbb Red 240 3 8Wor220210 Besl 03 Led Dsd Wbb Green 240 3 8Wor220211 Besl 03 Led Dsd Wbb Red 240 3 8W , Fiting & Fixtures 10 - Supply, Installation, Testing And Commissioning Of 600 Mm Sweep, Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current ( Bldc ) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2 Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value ( Cmm / W ) Minimum 6.85, Air Delivery Minimum 135Cmm, 350 Rpm ( Tolerance As Per Is : 374-2019 ) , Thd Less Than 10%, Remote Or Electronic Regulator Unit For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 Degree C ( Max. ) , Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc. Complete As Required. , Civil & Misc Works1 - Providing And Fixing M.V. Danger Notice Plate Of 200 Mm X 150 Mm, Made Of Mild Steel, At Least 2 Mm Thick, And Vitreous Enameled White On Both Sides, And With Inscription In Single Red Colour On Front Side As Required. , Civil & Misc Works2 - Providing And Fixing H.T. Danger Notice Plate Of 250 Mm X 200 Mm, Made Of Mild Steel, At Least 2 Mm Thick, And Vitreous Enameled White On Both Sides, And With Inscription In Single Red Colour On Front Side As Required. , Civil & Misc Works3 - Supplying And Making Cable Route Marker With Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) Of Size 60 Cm X 60 Cm At The Bottom And 50 Cm X 50 Cm At The Top With A Thickness Of 10Cm Including Inscription Duly Engraved As Required. , Civil & Misc Works4 - Supplying And Fixing Cable Route Marker With 10 Cm X 10 Cm X 5 Mm Thick G.I. Plate With Inscription There On, Bolted / Welded To 35 Mm X 35 Mm X 6 Mm Angle Iron, 60 Cm Long And Fixing The Same In Ground As Required. , Civil & Misc Works5 - Providing & Fixing In Position 1000 Mm Wide , Electrical Insulating Rubber Mats As Per Is 15652:2006, 2 Mm Thick, Suitable Up To 1.1 Kv , Fire Retardant, No Effect Of Acids, Alkalis And Transformer Oils, Moisture Proof, High Tensile Strengthandtexture Finish / Cloth Impression ( Anti Slip , Marking On Top ) , Civil & Misc Works6 - Supply & Fixing Shock Treatment Chart Duly Mounted On A Wooden Frame With 5 Mm Thick Glass As Required ( Approx Front Area 1.20 Sq Metre ) , 20 Kvaups - Supplying, Installation, Testing And Commissioningof Online Double Conversion Fully Microprocessor Based , Indoor Type, Compact Ups System Of Following Rating With Igbt Based Pwm Technology To Achieve Thd < 3% And Input Power Factor Of Greater Than 0.95 At 50% Loading, Suitable For Three Phase Ac Input Voltage 380 V To 440 V, 50 Hz +3% / - 3 % And Three Phase Ac Output Voltage 415 ± 1% Volts & Frequency 50 ± 0.5 Hz , Inbuilt Isolation Transformer, Necessary Vrla Batteries Of Suitable Size Having 30 Minutes Back Up Time , Mounting Rack Including And Suitable Size Connecting Cable ( For Ups To Battery And Battery To Battery ) , Static And Maintenance Bypass Switch, Snmp Card For Rs232 / Ethernet Ip Computability For Operation And Monitoring Etc. With All Components As Mentioned , Specifications, Complete As Required.Note : Concerning Vendor Needs To Furnish The Battery Sizing Calculations At The Time Of Ga Approval And Battery Size Has To Be As Per The Approved Ga Drawing. , External Lighting 1 - Supply And Erection Of 4 Metre Height Hot-Dip Galvanized Octagonal Street Light Pole With Following Arm With Top Dia 70 Mm And Bottom Dia A / F 130 Mm, Made Of 3 Mm Thick Sheet Along With Base Plate Of Size 220 X 220 X 12 Mm , Small Door Opening For Junction Box Mounting With Mcb & Connector, Cement Concrete Of 1:3:6 Including Excavation, Refilling And Suitable Size Foundation Bolts With Template And All Complete Jobas Required. ( But Without Pole Collar ) Single Arm , External Lighting 2 - Supplying And Fixing 40 / 45 Watt Led Type Street Light With Die Cast Aluminium Housing For Ingress Protection Of Ip65 And Complete With All Accessories Etc, Onpole / Building Including Connection With Fr Pvc Insulated Copper Conductor Cable And Earthing The Body Etc. As Required. , Transformer - Supplying, Installation Testing And Commissioning Of Following Rating, Distribution Transformer, Suitable For 3 Phase, 50Hz, Ac Supply, Dyn 11 Vector Group, Core Made Of Good Quality Crgo, Windings Made Of Double Wound Copper With Approved Danger And Arc Flash Signages And With All Components As Mentioned , Specifications And Sld And Complete As Required. Power Rating-250 Kva , 11 Kv Ht Dp Structure / Ht Cable 1 - Supplying 11Kv ( Earthed ) Grade, Xlpe Insulated, Heavy Duty Frls Type, Armoured Cables Suitable For 11Kv, 50Hz, Ac System With Inner And Outer Pvc Sheath, Outer Sheath Provided With Frls Insulation, Galvanised Steel Flat Armouring And With All Components As Mentioned In Boq, Specifications And Sld, Complete As Required.3 Core X 240 Sq. Mm , 11 Kv Ht Dp Structure / Ht Cable 2 - Supply, Installation, Testing And Commissioning Of 11 Kv Dp Structure As Per Cei & Hpseb Norms & Comprising Of The Following, But Not Limited To It For Completion Of Worksfor The Followingrsj Pole Of 9.15 Mt Length Of Size 175 X 90 Mm Complete With Suitable M.S. Base Plate Welded At Bottombase Plate - 2 Nos. , Indoor Cable End Termination 2 - Supplying And Making Indoor Cable End Termination With Heat Shrinkable Jointing Kit Complete With All Accessories Including Lugs Suitable For Following Size Of 3 Core, Xlpe Aluminium Conductor Cable Of 11 Kv Grade As Required. 300 Sq. Mm , Outdoor Cable End Termination - Supplying And Making Outdoor Cable End Termination With Heat Shrinkable Jointing Kit Complete With All Accessories Including Lugs Suitable For Following Size Of 3 Core, Xlpe Aluminium Conductor Cable Of 11 Kv Grade As Required. 300 Sq. Mm , Main Lt Panel - Main Lt Panel- ( Refer Sld For Detail ) Supply, Installation, Testing And Commissioning Of Indoor Floor Mounted / Wall Mounted, Ip42 ( Indoor ) And Ip55 ( Outdoor ) , Factory Built, Modular, Sectionalised, Compartmentalized, Extendable Type Lt Cubicle Panel Of Suitable Size Suitable For Operation On 433 / 415 Volts, 50 Hz Ac 3 Phase 4 Wire Supply System Fabricated From Crca Sheet Steel Of 2Mm Thick For , Apfc Panel - Apfc Panel - ( 200 Kvar ) -Outoor Type - ( Refer Sld For Detail ) , Ip Based Cctv System 1 - Sitc Of 2 Megapixel @ 25Fps, H.265 Ip Bullet Camera, 1 / 2.9 Cmos With 2.8~12Mm Varifocal Lens, 0 Lux With Night Vision Ir Up-To 30 Mtrs.Support Intelligent Analytics Like Abnormal Video Signal Detection, Video Mask, Heartbeat, Password Protection. Supports Digital Wdr, Icr, True D / N, 3D Dnr, Roi Coding, Poe, Onvif, Ip66 Etc. Complete As Required. , Cctv 2 - Sitc Of 2 Megapixel @ 25Fps, H.265 Ip Dome Camera, 1 / 2.9 Cmos With 3.6 Fixed Mm 0 Lux With Night Vision Ir Up-To 30 Mtrs.Support Intelligent Analytics Like Abnormal Video Signal Detection, Video Mask, Heartbeat, Password Protection. Supports Digital Wdr, Icr, True D / N, 3D Dnr, Roi Coding, Poe, Onvif, Ip66 Etc. Complete As Required. , Cctv 4 - Sitc Of 32Ch 4K Ivr , H.265 / H.264 • 1080P Real-Time • 4K Display • Dual Lan • 8X Hdd • Raid •Web Plugin Free H.265 / H.264 Compression Technology 4K Display For Clear Monitoring Up To 1080P 16Ch Decoding Ability Smart Search Ii Smart Vca Event Searchsupport Raid 0, 1, 5 Supported To Prevent From Recording Data Loss Browsers Supported: Ie , Smart Functions : Target Count, Electric Fence, Face Detection, Humaniod Detection, Retrograde Detection, Leave Position Detectio Output, Local & Network Backup Etc. Complete As Required. , Cctv 5 - Sitc Of Harddiskdrive8tb, 24 / 7Surveillance Category Only Complete Etc As Required.Etc.All Complete , Cctv 6 - Sitc Of 55 Led Narrow Bazel For Monitoring For Nvr Server Etc. All Complete. , Cctv 7 - Sitc Of Rj-45 Outlets Near The Cameras Etc. All Complete. Etc. All Complete. , Cctv 8 - Sitc Of Cat 6 Patch Cords 1 Meter High Quality Four Pair Twisted Stranded Cable Terminated With Rj45 Modular Plugs At Both The Ends. , Integrated It And Epabx System - Sitcof Cat-6 48 Port Jack Panel For Data As Per Given Specification Etc. All Complete. , Epabx System 2 - Sitcof Cat-6 48 Port Jack Panel For Voice As Per Given Specification Etc. All Complete. , Epabx System 3 - Sitc Of Lszh Cat 6 Speed Unshielded Twisted Pair Computer Cable With 23 Awg Solid Copper Conductors In Existing Concealed / Surface Conduits / Raceways Complete 305 Mtr. Roll As Per Specification Etc. All Complete. , Epabx System 4 - Sitc Of Cat6 Io, Face Plate, Wall Box Combo2- Port Etc. All Complete. , Epabx System 5 - Sitcof Cat-6 Mounting Cords 7 Feet For Data As Per Given Specification Etc. All Complete. , Epabx System 6 - Sitcof Cat 6 Patch Cords 4 Feet For Telephone As Per Given Specification Etc. All Complete. , Epabx System 7 - Sitc Of 24 Port L2 Managed 10 / 100 / 1000 Mbps Non Poe Switch With 4 Sfp Port , For Data Pointsrack Mountable Etc. All Complete. , Epabx System 8 - Sitc Of 24 Port L2 Managed Poe 10 / 100 / 1000 Mbps Switch With 4 Sfp Port , For Cctv Rack Mountable Etc. All Complete. , Epabx System 9 - Sitc Of 24 Port Smart Managed Non Poe With 4 Sfp Port Rack Mountable Etc. All Complete. , Epabx System 10 - Sitc Of 15 U Mountingrack With Ventilation, Sliding Shelves, Power Strips, Etc. All Complete. , Epabx System 11 - Sitc Of Ip Pbx For With 8 Trunk 1 Pri& 8 Digital And 32 Analog Extension Expendble Upto 64 Extesionsy Etc All Complete. , Epabx System 12 - 25 Pair Riser Cable , Epabx System 13 - Mdf Box25 Pair With 20 Pairkrone Module , Epabx System 14 - Supply, Installation, Testing & Commissioning Of Analog Phone With Speaker , Small Display Etc. All Complete. , Epabx System 15 - Client Workstation - Supply, Installation, Testing & Commissioning Of Client Workstation As Per Following Specifications:Intel Core I5-7700K, 4.2Ghz, Os -Genuine Microsoft Microsoft® Windows 10 Enterprise 64 Bit, Ram -16Gb, Memory -500 Gbssd +1Tb Hdd 7200 Rpm Class-Graphic Card - In-Built Processor Graphics ( Gpu ) :Intel® Hd Graphics 630 And Geforce Gtx 970-4Gb- Pcie X 16 Lp Supporting 2 / 4 Monitors., Two ( 2 ) Pci-Express Expansion Slots 2 / 4 Usb, 3.0 Serial, And 2 Hdmi / Vga Adaptor, Cd / Dvd Rom.; Usb Keyboard And Mouse, Ups, Associated Cables Etc. And Other Required Software To Control Nvr In Control Room Including Centralized Video Management Software As Per The Requirement Of The Successful Operation Of The Surveillance System Complete As Required In Accordance With Laid Specification Or Upto The Satisfaction Of Engineer In Charge. , Signage 1 - Providing & Fixing Of Building Direction Signage Mounted On Pole, With Pole Of 100X100mm Shs ( Square Hollow Section ) Of Height Of 5600Mm, And Sign Size Of 900X1050, Sign Made Of Aluminiu C Section Of 60Mm With Internal Framing To Support The Frame In Ms Tubes Hollow Section, Frame Work Duly Painted With Anti-Rust Coatings, With Facia Of 3Mm Thick Exterior Grade Aluminium Composite Panel, Cladded With Uv Cured Digital Printed Retroreflective Sheet Of 3M Make, And Back Panel Of 3Mm Exterior Grade Acp, All Pipes To Be Painted In Approved Color. Cost Shall Includecost Towards Installation, Including Excuvation And Filling Up With Specified Pcc And Fixing Of Foundation Bolts As Specified, Also It Shall Include The Designing Charges.All Complete As Per Direction By Engineer In Charge. , Signage 2 - Providing & Fixing Of Prohibition Sign Silk Screen Printed Of Approved Colors, On Acp Of Exterior Grade, Of Size 300X300mm, All Fixtures In Stainless Steel As Per Design, It Shall Include The Designing Charges .All Complete As Per Direction By Engineer In Charge. , Signage 3 - Providing & Fixing Traffic Regulatory Parking Signage Mounted On Pole, With Pole Of 50X50mm Shs ( Square Hollow Section ) Of Height Of 300Mm, And Sign Size Of 750X750, Sign Made Of Aluminium Sheet Of 3 Mm Thickness With Aluminium Supported Profile To The Frame Of Ms Tube Hollow Section, Aluminium Sheet To Be Cladded With Uv Printed Retroreflective Sheet Of 3M Make Frame Work Duly Painted With Anti Rust Coatings., All Pipe To Be Painted In Apppproved Color. Cost Shall Include Cost Towards Installation, Including Excuvation And Filling Up With Specified Pcc And Fixing Of Foundation Bolts As Specified, Also It Shall Include The Designing Charges.All Complete As Per Direction By Engineer In Charge. , Signage 4 - Providing And Fixing Of Signages Modular Curved Frame Technology Of Various Widths And Lengths To Fometre Suggested Usages Made Of Aluminium Extruded Sections. Duly Anodised All Signages Shall Be Provided With 0.6-0.8Mm Polycarbonate Protecting Film Over The Prints Of Appropriate Size .All Complete As Per Direction By Engineer In Charge , Wall Projected 250X210mm, Both Sides , Signage 5 - Providing And Fixing Of Signages Modular Curved Frame Technology Of Various Widths And Lengths To Fometre Suggested Usages Made Of Aluminium Extruded Sections. Duly Anodised All Signages Shall Be Provided With 0.6-0.8Mm Polycarbonate Protecting Film Over The Prints Of Appropriate Size .All Complete As Per Direction By Engineer In Charge, Door Mounted, 300X80mm , 2 Tr- Air Conditioning 1 - Split Ac ( Inverter Model ) : Supply, Installation, Testing, Commissioning Of Split Type Wall Mounted Air Conditioning Units Of Following Capacity Including Inddor, Outdoor Unit Fitted With Inverter Based Rotary Compressor Fitted With Rotary Compressor, Copper Condensor And First Charge Refrigent R410a / Eco Friendly Green Gas Only, All Complete Including All Electrical Connections To The Electrical Power Supply System Of The Building, Includingbut Not Limited To Supply Of All Electrical Plugs, Etc., As Necessary, Lengthening Of All Electrical Wires Of Ac Units ( Both Indoor And Outdoor ) , Drain Pipe Andincluding Suitable Voltage Stabilisers, Etc. So As To Place Them In A Concealed Manner In The Desired Position. The Copper Pipes And Electrical Cables Shall Be Concealed In Approved Manner And Neatly Run In Straight Lines In A Workman Like Manner With Proper Supports. Complete Supply And Installation Of Split2 Tr Star Rating 3 Star , Refrigerant Piping 1 - Copper Piping: Supply, Installation, Providing, Testing And Commisioning Of Interconnectiong Copper Refrigent Pipe Work ( 19Mm / 13 Mm Thick ) Duly Insulated With Elastomeric Nitrile Rubber, Joints Shall Be Covered With Nitrile Tape Of 3Mm Thick Complete As Per Specification Soft Refrigerant Copper Piping As Per Specifications And Drawings. 25 Mm Od, Wall Thickness >= 1.2 Mm ( Insulation 19 Mm Thick ) , Refrigerant Piping 2 - Copper Piping: Supply, Installation, Providing, Testing And Commisioning Of Interconnectiong Copper Refrigent Pipe Work ( 19Mm / 13 Mm Thick ) Duly Insulated With Elastomeric Nitrile Rubber, Joints Shall Be Covered With Nitrile Tape Of 3Mm Thick Complete As Per Specification Soft Refrigerant Copper Piping As Per Specifications And Drawings. 19.1 Mm Od, Wall Thickness >= 1.0 Mm ( Insulation 13 Mm Thick ) , Refrigerant Piping 3 - Copper Piping: Supply, Installation, Providing, Testing And Commisioning Of Interconnectiong Copper Refrigent Pipe Work ( 19Mm / 13 Mm Thick ) Duly Insulated With Elastomeric Nitrile Rubber, Joints Shall Be Covered With Nitrile Tape Of 3Mm Thick Complete As Per Specification Soft Refrigerant Copper Piping As Per Specifications And Drawings. 15.9 Mm Od, Wall Thickness >= 0.8 Mm ( Insulation 13 Mm Thick ) , Refrigerant Piping 4 - Copper Piping: Supply, Installation, Providing, Testing And Commisioning Of Interconnectiong Copper Refrigent Pipe Work ( 19Mm / 13 Mm Thick ) Duly Insulated With Elastomeric Nitrile Rubber, Joints Shall Be Covered With Nitrile Tape Of 3Mm Thick Complete As Per Specification Soft Refrigerant Copper Piping As Per Specifications And Drawings. 9.5 Mm Od, Wall Thickness >= 0.8 Mm ( Insulation 13 Mm Thick ) , Drain Piping 1 - Providing And Fixing Of Cpvc 6 Kg / Cm2 Drainpiping Complete With Fittings, Supports, 6 Mm Thick Closed Cell Elastomeric Insulation As Per Specifications And Drawings. 20 Mm , Drain Piping 2 - Providing And Fixing Of Cpvc 6 Kg / Cm2 Drainpiping Complete With Fittings, Supports, 6 Mm Thick Closed Cell Elastomeric Insulation As Per Specifications And Drawings. 32 Mm , Main Oxygen Manifold - Supply, Installation, Testing And Commissioning Of Following Gas Manifold System ( Excluding Cylinders ) . The Manifold Is Configured For Designed Numbers Of Cylinders And Is Suitable To Withstand A Pressure Of 145 Kg / Cm2, Along Withhigh-Pressure Copper Annealed Tail Pipes With End Brass Adapter Suitable For Cylinders And Manifold. Top Frame Comprising Of High Pressure Copper Pipes Of Size 1 / 2” Nb X 15Swg With High Pressure Brass Fittings Made Of High Tensile Brass And Connections Through Nonreturn Valves, The Design Of Middle And Bottomframes Is Provided To Fit Both Round And Flat Bottom Cylinders Safely. The Manifold Is Tested ( Hydraulically ) At 3500 Psig. ( It Should Be Ce And Iso 13485 Certified ) Mani Fold- Oxygen Manifold 4 + 4 Cylinder Banks Complete With Nrv, Middle Frame, Bottom Frame With Ce Marked, , Emergency Manifold - Emergency Oxygen Manifold- 01 + 01 Cylinder Emergency Manifold With Complete Regulator, Nrv, Middle Frame & Bottom Frame, , Control Panelfor Oxygen - Fully Automatic Three Port Control Panel For Oxygen Supply, Installation, Testing And Commissioning Of Automatic Manifold Control Panel Would Provide A Duty Or Standby Gas Supply From Two Cylinder Banks With Automaticchangeover The Manifold Indicates Local Status And Has A Remote Indicator Facility. Automaticmanifold Control Panel Would Be Designed To Supply The Mgps With A Constant Pressure Supply Via A Control Panel Form Two Equal Banks Of Cylinders And The Changeover From The , Emergency Manifold Line Regulator - Emergency Manifold Line Regulator Supply, Installation, Testing And Commissioning Of Emergency Manifold Line Regulator I N P U T P R E S S U R E 1 5 0 K G / C M 2 Working Pressure 4 Kg / Cm2 It Should Be Ce And Iso 13485 Certified.Oxygen Input Pressure 150 Kg / Cm2 Working Pressure 4 Kg / Cm2capacity : 1500 Lpm , Cylinderconnectingpipe ( Pig Tail ) - Supply, Installation, Testing And Commissioning Of Cylinder Connecting Pipe ( Pig Tail ) Made Up Of Flexible Ss Hose With Safety Cord 5 / 8 Inch Bsp Gland Nut And One Side 1 / 2 Inch Bsp Internal Threads Having One Meter Length. ( Oxygen -24 , N2o - 10, Co2-4 ) , Backpressurecompensated [ Bpc ] Oxygen Flowmeter - Supply, Installation, Testing And Commissioning Of Back Pressure Compensated [ Bpc ] Oxygen Flow Meter Body Should Be Made Of Brass Material Dully Chrome Plated And Graduated From 0-15 L / M On An Expanded Lower Scale Forprecision Setting At Low Flow And 5-15 L / M For General Use. The Humidifier Bottle Should Be Made Up Of Unbreakable Polycarbonate / Polysulphone Material And Autoclavable At 121 Degree Centigrade Temperature. It Should Be Ceand Iso 13485 Certified. , Oxygen Gas Outletfront Loadeddin / Bsstd - Gas Outlet Front Loaded Din / Bs Std:Supply, Installation, Testing And Commissioning Of Din / British Standard Gas Outlets Are For Use With Medical Gas System. The Gas Outlets Completely Complywith Htm2002 And C11 Standard Regulations And Pass The Test Of Leakage And Connector Stability. Medical Gas Outlet Shall Be Gas Specific For The Services Indicated And Accept Only Corresponding Din / British Standard Quickconnect Adapter. Specifically, Gas Specific Indexed To Eliminate Interchangeability Of Gas Services. The Gas Outlet Is Offered In Consoletype, Wall Type With Box And Hose Barb Type Gas System. It Should Be Ce And Iso 13485Certified. Din / Bis Std. Gas Outlets Feature And Benefits:* Comply With Htm2002 And C11 Standardregulations* Color Coded According To Iso32 Color*100% Pressure And Leak Tested* Full Range Of Mounting Options* Available In Wall Type With Box, Console Typeand Hose Barb Type* Gas Specific Adapters , Quickconnectadapter - Din / British Standard Quick Connect Oxygen Adapter ( Safety Probe ) , Tube - Oxygen H.P. Rubber Tube White Color, , Alarm - Supply, Installation, Testing And Commissioningof Area Pressure Alarm Panel Would Be Witdigital Display, Closed Circuit, Self-Monitoringtype. The Alarm Would Be Designed To Monitorthe Line Pressure In Piping Systems.It Should Be Ce And Iso 13485 Certified. Withfour Digit Notified No. Area Line Pressure Alarm-1 Gases , Isolation Valve, - Supply, Installation, Testing And Commissioning Of The Ball Valves [ For Dividing The Pipelines Into Various Zones For The Case Of Maintenance ] The Internal Ball With Full Borne Is Made Of Stainless Steel With Teflon Seats. These Valves Are Leakproof And Needs Only Quarter Turn For Its Operation [ Either Fully Open Or Fully Closed ] . It Should Be Ce And Iso 13485 Certified.42Mm , Isolation Valve 2 - Supply, Installation, Testing And Commissioning Of The Ball Valves [ For Dividing The Pipelines Into Various Zones For The Case Of Maintenance ] The Internal Ball With Full Borne Is Made Of Stainless Steel With Teflon Seats. These Valves Are Leakproof And Needs Only Quarter Turn For Its Operation [ Either Fully Open Or Fully Closed ] . It Should Be Ce And Iso 13485 Certified 28Mm , Isolation Valve 3 - Supply, Installation, Testing And Commissioning Of The Ball Valves [ For Dividing The Pipelines Into Various Zones For The Case Of Maintenance ] The Internal Ball With Full Borne Is Made Of Stainless Steel With Teflon Seats. These Valves Are Leakproof And Needs Only Quarter Turn For Its Operation [ Either Fully Open Or Fully Closed ] . It Should Be Ce And Iso 13485 Certified 22Mm , Isolation Valve 4 - Supply, Installation, Testing And Commissioning Of The Ball Valves [ For Dividing The Pipelines Into Various Zones For The Case Of Maintenance ] The Internal Ball With Full Borne Is Made Of Stainless Steel With Teflon Seats. These Valves Are Leakproof And Needs Only Quarter Turn For Its Operation [ Either Fully Open Or Fully Closed ] . It Should Be Ce And Iso 13485 Certified 15Mm , Isolation Valve 5 - Supply, Installation, Testing And Commissioning Of The Ball Valves [ For Dividing The Pipelines Into Various Zones For The Case Of Maintenance ] The Internal Ball With Full Borne Is Made Of Stainless Steel With Teflon Seats. These Valves Are Leakproof And Needs Only Quarter Turn For Its Operation [ Either Fully Open Or Fully Closed ] . It Should Be Ce And Iso 13485 Certified 12Mm , Pipeline 1 - Medical Grade Copper Pipeline ( In Mtrs. ) As Per En 13348, 12 Mm ( Od ) X 0.7 Mm Thickness , Pipeline 2 - Medical Grade Copper Pipeline ( In Mtrs. ) As Per En 13348, 15 Mm ( Od ) X 0.9 Mm Thickness , Pipeline 3 - Medical Grade Copper Pipeline ( In Mtrs. ) As Per En 13348, 22 Mm ( Od ) X 0.9 Mm Thickness , Pipeline 4 - Medical Grade Copper Pipeline ( In Mtrs. ) As Per En 13348, 28 Mm ( Od ) X 0.9 Mm Thickness , Pipeline 5 - Medical Grade Copper Pipeline ( In Mtrs. ) As Per En 13348, 42 Mm ( Od ) X 1.2 Mm Thickness , Hospital Sheet Patient Bedtype - Iii With Mattress - Overall Sizes: ( L ) 2268 Mm X ( W ) 922 Mm X ( H ) 610 Mmdescription: Sheet Bed Should Be A Plain Bed Used In The Recovery Ward.Material Specifications: Under Structure Has A Higher Diameter Tubewhich Should Provide A Sturdy Understructure.Lying Surface Area Of Crca , Paediatric Bed With Mattress - Paediatric Bed Of Overall Sizes In Mm: 1500 ( L ) X 850 ( W ) X 1210 ( H ) Flat Single Section Bed With Grille Frame On 4 Sides.Suitable For Children Up To 12 Years.Drop Down Grill Frame On Both Sides For Protection Of The Patient.Material Specifications: Under Structure Has A Higher Diameter Tubewhich Should Provide A Sturdy Understructure.Lying Surface Area Of Crcafinish Specifications: Head Board / Leg Board Should Be Made Of Frame Ms Erw Roundtube Of Sections Ø19, Ø25.4& Ø31.75Mm, Ofthickness1.6 Mmprovision For Mounting Of Iv Pole And Mosquito Net Pole Should Be Presentfinish Specifications: Powder Coating Should Be Bacteriostatic And Thermosetting Epoxy Polyester, Formulated To Fulfill The Requirements For Bacterial Protection.All Powder Coated Parts In Ral White , Bed Side Locker Type I - Over All Dimension :402Mmlx422mm Wx840mm Ht .Locker Should Have One Cabinet And One Drawer Unit .Both Provided With Cam Lock .There Should Be Gap Between Drawer And Unit To Keep General Items For Frequesnt Use Castors Are Provided For Easy Handling .Drawer Made Up Of Crca Sheet 1 Mm Thick And Has Ball Slide For Easy Operation .Top Ss 304 Sheet 0.8 Mm Thick Castors 50 Mmdia , Hamdle Abs ..Powder Coating Of Epoxy Polyester , Medicinetrolleytype -I - Overall Size902mm ( L ) X532mm ( W ) X915mm ( H ) .Top Shelf Should Be Made Of Ss 304 Sheetof 1 Mm Thick. Supporting Legs Made Of Ss304 Tubesection 30.30 Mm Dia.Of 1.2 Mm Thick Provided To Suppoort The Entire Structure.Ss 304 Tube Provided At The Bottom For Placement Of Instument Being Used .Handle Made Up Of Ss 304 Tubeof Dia Dia 16 Mmand Thickness 1.2 Mm Provided To Handle Trolley .And Maneuver Accordingly. High Endurance Anti Static Plastic Injection Moulded Castors Of 125 Mm Dia.Ss Should Be Finished In Glossy Mirror Finish. Max Load Capacity Of 10 Kg / Shelf Udl , Round Stooltype -I - Overall Sizes Diagonal Legdia 538 Mmh470 Min-655Max.Ss 202 Made Sheet With Spin Section Of Thickness 1Mm & Should Be Non Corrosive. It Should Have A Diameter Of 305Mm, Seat Base Is Made Of Ms Ring And Rectangular Tube.En8 Screw Having Dia Of 22 Mm Should Be Used For Height Adjustment Of The Seat Base.The Hub Should Be Made Of Ms Erw Tube Having Dia Of 38Mm And Thickness 2 Mm.The Hub Should Be Welded With The Legs And It Should Accommodate And Cover The Lead Screw Mechanism.The Understructure Should Consist Of 4 Legs Made Up Ofms Erw Tube Of Diameter 25.4 Mm And 1.6Mm Thick. The Press Formed Pipe Leg Should Give A Round & Clean Look. All The Legs Should Be Provided With 4 Nos Of Nylon-6 Bush.All Metal Componentsshould Be Pre Treated With Zinc Phosphating In 9 Tank Process And Then Powder Coated With Anti Microbialepoxy Polyster Powder Coating . All Welding Should Be Co2 Argon Welding To Minimise Rusting On The Welding Areas.Safe Working Load Must Be 135Kg , Strecher On Trolley Type - I - 2005Mm ( L ) X666mm ( W ) X827mm ( H ) .The Trolley Should Be Made Of 31.75 And 25.4 Mm Dia 1.6 Mm Thick Erw Tube.Holder For Stretcher Should Be Made Up Of Mild Steel.Castor Should Be Of 200 Mm Dia , Diagonal Locking Castor.Stretcher Should Be Made Up Oferw Tubeof Dia 25.4 Mm And Thickness 1.6 Mm.Top Sheet Should Be Made Of Crca Sheetof Thickness 1.2 Mm With Contour Shape To Accommodate Patient.Iv Pole Holder Should Be Made Ofms .Maximum Safe Work Load Should Be 135 Kg.To Ensure Qood Quality Welding Co2 ArgonProcess Should Be Adhered To.All Metal Componentsshould Be Pre Treated With Zinc Phosphating In 9 Tank Porcess And Then Powder Coated With Anti Microbialepoxy Polyster Powder Coating.Goods Should Be Supplied In Knocked Down Construction To Reduce Carbon Emission. Performance Test :Proof Loading Test , Cycle Tests , Impact Test, Salt Spray Test, Castor Break Test, The Manufacturer Should Compilant With Iso 9001, 14001, 13485, Ohsas 1800 And Ce Certification. , Doctor Desk Type -X - S / F / F Executive Table Main Desk Should Be Of Dimesion : 1350W X 750D X 750H.The Table Top Should Bein White Cedar, Side Panelsin Black, While The Modestypanel Ina Combination Of Black & White Cedar. Side Panels : ( Black ) Made Form 18Mm Thick Plt With Pvc Lipping.Modesty Panel : Made Form 18Mm Thick Plt With Pvc Lipping. Bigger Upper Panel In Black And Smaller Lower Panel In White Cedar. Made From 18Mm Thick Plt With Pvc Lipping. Mobile Pedestal : One Box And One Filing Drawer With 18Mm Thick Plb Fronts And Top. Handles : Black Powder Coated Die Cast Aluminum Alloy Handles. Mobile Pedestal And Hdu Are Fitted With Central Lock. , Chair Type Iii - S / F / F Executive Chair1 ) Seat / Back Assembly: The Seat And Back Are Made Up Of 1.2 Cm. Thick Hot-Pressed Plywood, Upholstered Withfabric Upholstery Covers And Moulded Polyurethane Foam. The Back Foam Is Designed With Contoured Lumbar Support For Extra Comfort. The Seat Has Extra Thick Foam On Front Edge To Give Comfort To Popliteal Area.High Back Size : 47.5 Cm ( W ) X 69.5 Cm ( H ) Seat Size : 47.0 Cm. ( W ) X 48.0 Cm. ( D ) 2 ) Polyurethane Foam: The Polyurethane Foam Is Moulded With Density = 45 + / -2 Kg / M 3And Hardness = 20 + / - 2At 25% Compression. 3 ) Armrests: The One-Piece Armrests Are Injection Moulded From Black Co-Polymer Polypropylene. 4 ) Center Tilt Synchro Mechanism : The Mechanism Is Designed With The Following Features:· 360 Revolving Type. · Upright Position Locking. · Tilt Tension Adjustment.· Seat / Back Tilting Ratio Of 1:3 ( 60 Seat Tilt / 180 Back Tilt ) . 5 ) Pneumatic Height Adjustment : The Pneumatic Height Adjustment Has Anadjustment Stroke Of 12.0 Cm. 6 ) Telescopic Bellow Assembly : The Bellow Is 3 Piece Telescopic Type And Injection Moulded In Black Polypropylene. 7 ) Pedestal Assembly : The Pedestal Is Injection Moulded In Black 30% Glass-Filled Nylonand Fitted With 5 Nos. Twin Wheel Castors. The Pedestal Is 66.0Cm Pitch-Center Dia. ( 76.0 Cm With Castors. ) 8 ) Twin Wheel Castors : The Twin Wheel Castors Are Injection Moulded In Black Nylon. , Staff Chair Type I - Chair Of Over All Size: 58.0Cm ( W ) X 56.5Cm ( D ) X 87.5Cm ( H ) & 48.0Cm ( Sh ) Seat / Back Assembly: The Seat And Back Are Made From Chemically Treated And Seasoned Wood, Upholstered With Plywood, Black Leather-Cloth, And U-Foam.*Back Size: 46.0Cm ( W ) X 27.0Cm ( H ) .*Seat Size: 46.0Cm ( W ) X 40.0Cm ( D ) .Armrest Tube: The Armrest Tube Is Made Of M.S. E.R.W. Tube Dia. 2.54Cm. ( 1” ) X 16Bg Thick And Powder Coated.Armrest: The Armrest Is Gas-Assisted Injection Moulded From Black Polypropylene.Understructure Assembly: The Understructure Assembly Is A Cantilever Type Frame Made Of Dia. 2.54Cm. ( 1” ) X 14Bg. Thick M.S. E.R.W. Tube And Powder Coated. , Visiter Chair Type V - S / F / F Visitor Chair1 ) Seat / Back Assembly: The Seat And Back Are Made Up Of 1.2 Cm. Thick Hot-Pressed Plywood, Upholstered With Fabric Upholstery Covers And Moulded Polyurethane Foam. The Back Foam Is Designed With Contoured Lumbar Support For Extra Comfort. The Seat Has Extra Thick Foam On Front Edge To Give Comfort To Popliteal Area. Mid Back Size : 47.5 Cm. ( W ) X 58.0Cm. ( H ) Seat Size : 47.0 Cm. ( W ) X 48.0 Cm. ( D ) 2 ) Polyurethane Foam: The Polyurethane Foam Is Moulded With Density = 45 + / -2 Kg / M 3And Hardness = 20 + / - 2At 25% Compression. 3 ) Armrests: The One-Piece Armrests Are Injection Moulded From Black Co-Polymer Polypropylene. 4 ) Tubular Frame : The Powder Coated Tubular Frame Is Cantilever Type & Made Of Dia 25.4Mm X 2Mm Thk M.S. Er.W. Tube. , Wheel Chair Type - I - ( L ) 790 X ( W ) 600 X ( H ) 870Mm.Foldable Frame Structure Should Be Made Of Section 22Diax1.2Mm A3 Carbon Steel With Chrome Finish. Cross Bar Should Be Made Of A3 Carbon Steel With Section 25.4 X 1.2Mm.Rear Wheel:24 Inch Solid Mag Wheels With Alloy In The Rim .Integrated Handrim Provide To Drive The Wheel Chair Of Section 16X1.2Mm A3 Carbon Steel With Chrome Finish.Front Wheel :8 Inch Hub Made Of Pa Polymer And Outer With Solid Rubber.Pu Molded Arm Rest & Base Should Be Made Of Abs For Better Arm Support .Leatherite Strap For Calf Rest & Leatherite Cushion For Seat.Adjustable Alluminimum Die Cast Foot Rest With Updown & Swivel Type Mechanism.Handles Should Be Made Of Moulded Rubber Grip To Push The Wheelchair.Hand Brakes Should Be Provided To Lock The Wheelchair At Desired Location.Foot Pressextended Base With Molded Plastic For Better Grip.Anti Rust Chrome Finsh. Safe Work Load Of100 Kg , Basin Stand Type I - Ht 850 Mm Ss Bowl Ms Tubular Frame Of Dia 25.4 X1.2 Mm Tube Work Mounted On Three 50 Dia.Non Rusting Castors All Without Brack. Ss Part Finished With Matt Polish , Kick Buckettype -I - Overa All Dimension Of The Bucket Should Be 517 Mm ( L ) X 517 Mm ( W ) X 210 Mm H.It Should Made Of 12.7 Mm Dia And 1.6 Mm Thick Ss 304 Ring. The Bowl Should Be Ss Made Of .8 Mm Thck .3 Nos 50 Mm Diahigh Endurance Plasticinjection Moulded Castors Should Be Provided For The Movement.Mx Load Bearing Capacity Should Be 10 Kg. , Instrument Cabinet Type -I - Overall Dimensions Of 900Mmwx 1990Mmhx450mmd And Should Have Transparent Doors And Sides With Steel Frame Work. Transparent Portion Of This Cupboard Should Be Made Of Acrylic Of 4Mm Thick. This Cabinet Should Have 5 Adjustable Acrylic Shelves Each Of 6 Mm Thickness. Three Way Lock Should Be Provided Of 6 Levers. In The Front Door There Should Be 4 Acrylic Sheets And 2 Each On Both The Sides. Metal Used Should Be Of Crca And Powder Coated For Finish. To Be Provided With Rubber Shoes To Prevent Direct Contact Of Cabinet And Floor. , Hospital Curtain Tracks & I.V. Tree System - Supply Installation Testing & Commissioning Of Cubical Tracks System Made Of Powder Coated Aluminium Alloy, Stain Free Polyster Fabric , Water Repellent Curtains , Smooth Movement , Non Sticking Runnner With Stainless Steel Hooks Made From Mirror Finish Stainless Steel , Adjustable Height With All Accessories. Total Quantity : 1

Tender Notice

29767105

Indian


Bihar

November 23, 2021

Key Value

Ref. Documents

Ref. Documents

Ref. Documents

To Download Tender Document Click on the below link

Bids Are Invited For Pile - Boring, Providing And Installation Bored Cast-In-Situ Reinforced Cement Concrete Piles Of Grade M-25 Of Specified Diameter And Length Below The Pile Cap, To Carry A Safe Working Load Not Less Than Specified, Excluding The Cost Of Steel Reinforcement But Including The Cost Of Boring With Bentonite Solution And Temporary Casing Of Appropriate Length For Setting Out And Removal Of Same And The Length Of The Pile To Be Embedded In The Pile Cap Etc. By Percussion Drilling Using Direct Mud Circulation ( Dmc ) Or Bailer And Chisel Technique By Tripod And Mechanical Winch Machine All Complete, Including Removal Of Excavated Earth With All Its Lifts And Leads ( Length Of Pile For Payment Shall Be Measured Up To Bottom Of Pile Cap ) .450Mm Dia Piles ( Inclusive Of Carriage ) , Pcc - Providing And Laying In Position Cement Concrete Of Specified Gradeexcluding The Cost Of Centering And Shuttering - All Work Up To Plinthlevel : 1:3:6 ( 1 Cement : 3 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) ( Inclusive Of Carriage ) , Rcc - Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland / Portland Slag Cement, Admixtures In Recommended Proportion As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge; For The Following Grades Of Concrete. Note: Extra Cement Up To 10% Of The Minimum Specified Cement Content In Design Mix Shall Be Payable Separately. In Case The Cement Content In Design Mix Is More Than 110% Of The Specified Minimum Cement Content, The Contractor Shall Have Discretion To Either Re-Design The Mix Or Bear The Cost Of Extra Cement. ( Inclusive Of Carriage ) , Brick Work - Brick Work With Bricks Of Class Designation 100A In Foundations And Plinthin :Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) ( Inclusive Of Carriage ) , Sand Filing - Supplying And Filling In Plinth With Sand Under Floors, Including Watering, Ramming, Consolidating And Dressing Complete. ( Inclusive Of Carriage ) With Lead Upto 3 Km , Shuttering - Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete , Reinforment Steel - Steel Reinforcement For R.C.C. Work Ready To Use Cut And Bend Rebars Of Approved Make From Factory / Workshop To Construction Site Including Placing In Position And Binding All Complete Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More. , Plinth Protection - Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand ( Zone-Iii ) Derived From Natural Sources : 6 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources ) Over 75Mm Thick Bed Of Dry Brick Ballast 40 Mm Nominal Size, Well Rammed And Consolidated And Grouted With Fine Sand, Including Necessary Excavation, Levelling & Dressing & Finishing The Top Smooth. , Door & Window - Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. ( Glazing, Paneling And Dash Fasteners To Be Paid For Separately ) :Powder Coated Aluminium ( Minimum Thickness Of Powder Coating 50 Micron ) , Glass - Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item ) :With Float Glass Panes Of 5 Mm Thickness ( Weight Not Less Than 12.50 Kg / Sqm ) , Upvc Door - Providing And Fixing Of Factory Made Upvc White Colour Casement Door, Upvc Multichambered Extruted Frame, Sash And Mullion Profile. Frame Duly Reinforced With 1.2Mm Gi Section Box Tpe Chamber And Sash With 1.5Mm Thick Gi Section ( ± 0.2Mm ) Based On Wind Load Calculations ( Shape And Size According To Upvc Profiles ) , Appropiate Dimentions Of Upvc Extruded Glazing Bead, Epdm Gasket ( K / O Type ) , Seperate Drainage System, Ss34 Grade Friction Hinges 2D / 3D Plate Hinges, Zinc Alloy ( White Powder Coated ) Casement Handle, Gi Fastener 8X100 Mm Size For Fixing Frame To Finish Wall, Plastic Packer And Caps And Necessary Steel Screws Etc.Profile Of Frame And Sash Shall Be Metered Cut And Fusion Welded At All Corners, Mullion Shall Be Also Fusion Welded / Joined Mechanically Including Drilling Of Holes For Fixing Hardware And Drainage Of Water Etc. After Fixing Of Frames , Gap Between Frame And Adjascent Wall Shall Be Filled With Pu Foaam / Backer Rod Required Size And The Approved Quantity. After That Sealed With Weather Proof Silicon Sealant At Both Side, All Complete As Per Approved Drawing And Direction Of Eic , Door Closer - Providing And Fixing Aluminium Die Cast Body Tubular Type Universal Hydraulic Door Closer ( Having Brand Logo With Isi, Is : 3564, Embossed On The Body, Door Weight Upto 35 Kg And Door Width Upto 700 Mm ) , With Necessary Accessories And Screws Etc. Complete. , Door - Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 ( Part I ) Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters. 30 Mm Thick Including Stainless Steel Butt Hinges Wirhnecessary Screws , Door Stopper - Providing And Fixing Aluminium Hanging Floor Door Stopper, Isi Marked, Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour And Shade, With Necessary Screws Etc. Complete. Single Rubber Stopper , Soling - Providing Designation 100 A One Brick Flat Soling Joints Filled With Local Sand Including Cost Of Watering, Taxes, Royalty All Complete As Perbuilding Specification And Direction Of E / L, , Tile 1 - Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3 Kg / Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm , Tile 2 - Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm ( Thickness To Be Specified By The Manufacturer ) Of 1St Quality Conforming To Is : 15622 Of Approved Make In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3 Kg / Sqm Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete. , Tile 3 - Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 ( Thickness To Be Specified By The Manufacturer ) , Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , Granite - Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm ( Average ) Thick Base Of Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge :Flamed Finish Granite Stone Slab Jet Black, Cherry Red, Elitebrown, Cat Eye Or Equivalent. , False Ceiling - Providing And Fixing Mineral Fibre False Ceiling Tiles At All Heights Of Size 595X595mm Of Approved Texture, Design And Pattern. The Tiles Should Have Humidity Resistance ( Rh ) Of 99%, Light Reflectance ? 85%, Thermal Conductivity K = 0.052 - 0.057 W / M K, Fire Performance As Per ( Bs 476 Pt - 6 &7 ) In True Horizontal Level Suspended On Interlocking T-Grid Of Hot Dipped All Round Galvanized Iron Section Of 0.33 Mm Thick ( Galvanized @120 Gsm ) Comprising Of Main T Runners Of 15X32 Mm Of Length 3000 Mm, Cross T Of Size 15X32mm Of Length 1200 Mm And Secondary Intermediate Cross T Of Size 15X32 Mm Of Length 600 Mm To Form Grid Module Of Size 600X600 Mm Suspended From Ceiling Using Galvanized Mild Steel Item ( Galvanised@80Gsm ) 50 Mm Long 8Mmwith 16 Mm Thick Beveled Tegular Mineral Fibre AntiMicrobial False Ceiling Tile Confirming To Iso 5 ( Class 100 ) Specifications , Pre-Fabsteel - Designing, Providing, Installing And Fixing Factory Finished Custom Designed Cold Form Light Gauge Steel Framed Super Structure Comprising Of Steel Wall Panel, Trusses, Purlins Etc Manufactured Out Of Minimum 0.75 Mm Thick Steel Sheet As Per Design Requirements. The Steel Sheet Shall Be Galvanized ( Az-150Gms Aluminium Zinc Alloy Coated Steel Having Minimum Yield Strength 300-550 Mpa ) Conforming To Aisi Specifications And Ibc 2009 For Cold Formed Steel Framing And Construction And Also As Per Is: 875-1987, Iso 800-1984 And Is:801- 1975. The Wind Load Shall Be As Per Provisions Of Is 875 ( Part -Iii ) . Lgsfs Frame Shall Be Designed As Per Is: 801 Using Commercially Available Software Such As Frame Cad Pro-11.7 / Staad Pro-V8i / Architekv2.5.16 / Revit Architecture-2011 Or Equivalent. Proper Usage Of Connection Accessories Like Heavy Duty Tension Ties, Light Duty Hold-Ons, Twist Straps ( To Connect Truss With Wall Frames ) , Strong Tie, Tie Rod, H-Brackets, Boxing Sections, L-Shaped Angles For Better Structural Stability. The Framing Section Shall Be Cold Form C-Type Having Minimum Web Depth 89 Mm X 39Mm Flange X 11Mm Lip In Required Length As Per Structural Design Requirement Duly Punched With Dimple / Slot At Required Locations As Per Approved Drawings. , Pre-Fabwall - Providing And Fixing Of External Wall System On Light Gauge Steel Frame Work With Outer Face Cement Boards As Per Standard Sizes Fixed With Self- Drilling / Taping Screws / Fasteners @ 60Cm C / C Of Approved Make. , Pre-Fabin. Wall - Providing And Fixing Internal Wall Panels On Light Gauge Steel Frame Work With 12.5Mm Thick Gypsum Plaster Board Conforming Is 2095:2011 Fixed On Cement Board As Per Standard Sizes Fixed With Self-Drilling / Taping Screws / Fasteners @ 60Cm C / C Of Approved Make, Screws Shall Be Of Counter Sunk Rib Head Of 1.60Mm To 4 Mm Thick Or 8 To 10 Gauge Of Length Varying From 25 To 45 Mm. Proper Taping And Jointing To Be Done Using Fiber Mesh Tape And Epoxy And Acrylic Based Jointing Compound For Seamless Finish. ( Cost Of Frame Work To Be Paid For Separately , Roof Sheet - Supply & Installation Of Precoated Galvanised Iron Profile Sheets ( Size, Shape And Pitch Of Corrugation As Approved By Engineer-In-Charge ) 0.50 Mm + / - 5% Total Coated Thickness ( Tct ) Thick Zinc Coating 120Gsm As Per Is: 277 In 240Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches While Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineer-In-Charge. The Sheet Shall Be Fixed Using Self Drilling / Self Tapping Screws Of Size ( 5.5X 55Mm ) With Epdm Seal Or With Polymer Coated J Or L Hooks, Bolts And Nuts 8Mm Diameter With Bitumen And G.I. Limpet Washers Or With G.I. Limpet Washers Filled With White Lead Complete Upto Any Pitch In Horizontal / Vertical Or Curved Surfaces Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. , Ridge Plain - Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories 0.50 Mm + / - 5% Total Coated Thickness ( Tct ) Thick Zinc Coating 120Gsm As Per Is: 277 In 240Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling / Self Tapping Screws Or With Polymer Coated J Or L Hooks, Bolts And Nuts And Or G.I. Seam Bolts And Nuts, G.I. Plain And Bitumen Washers Complete : Ridges Plain ( 500 - 600Mm ) . , Gutter Drain - Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories 0.50 Mm + / - 5% Total Coated Thickness ( Tct ) Thick Zinc Coating 120Gsm As Per Is: 277 In 240Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns Using Self Drilling / Self Tapping Screws Or With Polymer Coated J Or L Hooks, Bolts And Nuts And Or G.I. Seam Bolts And Nuts, G.I. Plain And Bitumen Washers Complete : Gutter , Flashing - Providing And Fixing Precoated Galvanised Steel Sheet Roofing Accessories 0.50 Mm + 5% Total Coated Thickness ( Tct ) , Zinc Coating 120Gsm As Per Is: 277 In 240Mpasteel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Topcoat 15-18 Microns Using Self Drilling / Self Tapping Screws Or With Polymer Coated J Or L Hooks, Bolts And Nuts And Or G.I. Seam Bolts And Nuts, G.I. Plain And Bitumenwashers Complete :Flashings / Aprons. ( Upto 600 Mm ) , Under Deck Insulation - Providing And Fixing Thermal Insulation Of Ceiling ( Under Deck Insulation ) With Resin Bonded Rockwool Conforming To Is: 8183, Density 48 Kg / M3, 50 Mm Thick, Wrapped In 200 G Virgin Polythene Bags Fixed To Ceiling With Metallic Cleats ( 50X50x3 Mm ) @ 60 Cm And Wire Mesh Of 12.5Mm X 24 Gauge Wire Mesh, For Top Most Ceiling Of Building. , Resin Bonded Rock Wool - Providing And Fixing Thermal Insulation With Resin Bonded Rock Wool Conforming To Is: 8183, Having Density 48 Kg / M3, 50 Mm Thick, Wrapped In 200 G Virgin Polythene Bags Fixed To Wall With Screw, Rawel Plug & Washers And Held And In Position By Criss Cossing Gi Wire Etc. Complete As Per Directions Of EngineerIn- Charge. , Face Panel - Providing And Fixing In All Exterior Face Panels Breathable Vapour Barrier Underneath The Cementfiber Board As Per National Building Code 2009 Complete As Per Direction Of Engineer-In-Charge. , Lap Siding - Supplying And Installation Of Moisture Resistant / Fire Resistantlap Siding 8 Mm Thick And Width As Per Standard Sizes Made Ofiber Cement Board With Embossed Decorative Finish To Give Pleasing Exterior Fixed Horizontally With Staggered Joints Including Minimum Over Lapof 32 Mm External Cement Fibre Boardconforming To Is 14862:2000 Offixed With Self-Drilling / Taping Screws / Fastners Of Approved Make. , Putty - Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Distemper - Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade : 1- New Work ( Two Or More Coats ) Over And Including Water Tinnable Priming Coat With Cement Primer , Ex. Paint - Finishing Walls With Textured Exterior Paint Of Required Shade : New Work ( Two Or More Coats Applied @ 3.28 Ltr / 10 Sqm ) Over And Including Priming Coat Of Exterior Primer Applied @ 2.20Kg / 10 Sqm Sqm , Oil Paint - Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work . , Steel-2 - Steel Work In Built Up Tubular ( Round, Square Or Rectangular Hollow Tubes Etc. ) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. Hot Finished Welded Type Tubes , Excavation - Earth Work In Excavation Over Areas ( Exceeding 30 Cm In Depth. 1.5 M In Width As Well Es 10 Sqm On Plan ) Including Disposal Of Excavated Earth , Lead Upto 50 M And Lift Upto 1.5 M; Disposed Earth To Be Levelled And Neatly Dressed. , Road - Providing And Laying C.C. Pavement Of Mix M-25 With Ready Mixed Concrete From Batching Plant. The Ready Mixed Concrete Shall Be Laid And Finished With Screed Board Vibrator , Vacuum Dewatering Process And Finally Finished By Floating, Brooming With Wire Brush Etc.Complete As Per Specifications And Directions Of Engineer-In- Charge. ( The Panel Shuttering Work Shall Be Paid For Separately ) . ( Note:- Cement Content Considered In This Item Is @ 330 Kg / Cum. Excess / Less Cement Used As Per Design Mix Is Payable / Recoverableseparately ) . , Paver Block - Providing And Laying 60 Mm Thick Factory Made Cement Concrete Interlocking Paver Block Of M -30 Grade Made By Block Making Machine With Strong Vibratory Compaction, Of Approved Size, Design & Shape, Laid In Required Colour And Pattern Over And Including 50 Mm Thickcompacted Bed Of Coarse Sand, Filling The Joints With Fine Sand Etc. All Complete As Per The Direction Of Engineer-In-Charge. , Phe 1 - Providing And Fixing Salem Stainless Steel A Isi 304 ( 18 / 8 ) Kitchen Sink As Per Is: 13983 With Ci Brackets And Stainless Steel Waste With Plug 40Mm Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required.Kitchen Sink With Drain Board 510X1040mm Bowl Depth 200Mm. , Phe 2 - Providing And Fixing Salem Stainless Steel A Isi 304 ( 18 / 8 ) Kitchen Sink As Per Is: 13983 With Ci Brackets And Stainless Steel Waste With Plug 40Mm Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required.Sink Without Drain Board 610X510 Mm Bowl Depth 200Mm. , Phe 3 - Providing And Fixing Mirror Of Superior Glass ( Of Approved Quality ) And Of Required Shape And Size With Plastic Moulded Frame Of Approved Make And Shade With 6 Mm Thick Hard Board Backing:Rectangular Shape 453X357 Mm , Phe 4 - Providing And Fixing Toilet Paper Holder:C.P. Brass , Phe 5 - Providing And Fixing Water Closet Squatting Pan ( Indian Type W.C.Pan ) With 100 Mm Sand Cast Iron P Or S Trap, 10 Litre Low Fixturescomplete, Including Cutting And Making Good The Walls Andlevel Whitep.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlleddevice ( Handle Lever ) Conforming To Is : 7231, With All Fittings Andfloors Wherever Required :White Vitreous China Orissa Pattern W.C. Pan Of Size580x440 Mm With Integral Type Foot Rests , Phe 6 - Providing And Fixing White Vitreous China Pedestal Type Water Closet ( European Type W.C. Pan ) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device ( Handle Lever ) , Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required : W.C. Pan With Isi Marked White Solid Plastic Seat And Lid , Phe 7 - Providing And Fixing 8 Mm Dia C.P. / S.S. Jet With Flexible Tube Upto 1 Metre Long With S.S. Triangular Plate To Eureopean Type W.C. Of Quality And Make As Approved By Engineer - In-Charge , Phe 8 - Providing And Fixing Cp Brass 32Mm Size Bottle Trap Of Approved Quality & Make And As Per The Direction Of Engineer-In-Charge.. ( Sink & Urinal ) , Phe 9 - Providing & Fixingptmt Towel Ring Trapezoidal Shape 215 Mm Long 200 Mm Wide With Minimum Distance Of 37 Mm From Wall Face With Concealedfittings Arrangement Of Approved Quality And Colour Weighing Not Less Than 88 Gms , Phe 10 - Providing And Fixing C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards And Weighing Not Less Than 690 Gms.15Mm Nominal Bore , Phe 11 - Providing And Fixing C.P. Brass Bib Cock Of Approved Quality Confirming To Is:893115Mm Nominal Bore , Phe 12 - Providing And Fixing C.P.Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is 8931 A ) 15 Mm Nominal Bore.15 Mm Nominal Bore , Phe 13 - Providing And Fixing Wash Bashin With C.I. Brackets, 15Mm Dia Cp Brass Singal Hole Basin Mixer Of Approved Quility And Make, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required -White Vitreous China Surgeon Type Wash Basin Of Size660x460 Mm With A Pair Of 15 Mm C.P. Brass Pillar Tapswith Elbow Operated Levers , Phe 14 - Providing & Fixing Chrome Plated Brass Battery Based Infrared Sensor Operated Pillar Cock, Having Foam Flow Technology. , Phe 15 - Providing And Fixing White Vitreous China Laboratory Sink With C.I. Brackets, C.P. Brass Chain With Rubber Plug, 40 Mm C.P Brass Waste And 40Mm C.P. Brass Trap With Necessary C.P. Brass Unions Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Wall Wherever Required :Size 600X450x200 Mm , Phe 16 - Providing And Fixing Cp Brass Single Lever Telephonic Wall Mixer Of Quality & Make As Approved By Engineer In Charge . A ) 15 Mm Nominal Dia. , Phe 17 - Providing And Fixing Cp Brass Shower Rose With 15 Or 20 Mm Inlet100 Mm Diameter , Phe 18 - Providing And Fixing Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour.600 Mm Long Towel Rail With Total Length Of 645 Mm, Width 78 Mm And Effective Height Of 88 Mm, Weighing Not Less Than 190 Gms. , Phe 19 - Providing And Fixing Ptmt Liquid Soap Container 109 Mm Wide, 125 Mm High And 112 Mm Distance From Wall Of Standard Shape With Bracket Of The Same Materials With Snap Fittings Of Approved Quality And Colour, Weighing Not Less Than 105 Gms. , Phe 20 - Providing And Fixing G.I. Pipes Complete With Gi Fittings And Clamps Including Cutting And Making Good The Walls Etc. ( Internal Work ) 40 Mm Dia, Nominal Bore , Phe 21 - Providing And Fixing G.I. Pipes Complete With Gi Fittings And Clamps Including Cutting And Making Good The Walls Etc. ( Internal Work ) 50 Mm Dia, Nominal Bore , Phe 22 - Two Or More Coats On New Work Over An Under Coat Ofsuitable Shade With Ordinary Paint Of Approved Brand Andmanufacturetwo More Coast On New Work , Phe 23 - P / F M.S. Cap 100 Mm Dia , Phe 24 - Providing And Fixing, Upvcpipes 6 Kg / Cm2 ( Is: 4985 ) Including All Fittings ( Plain Or Door ) E.G. Bends, Junction, Offsets, Access Pieces, Jointing With Rubber Ring / Solvent Cement Joints Includingrequired Suports, Cutting Chase Or Holes In Walls And Floors And Making Good Where Required.75 Mm Dia Pipe , Phe 25 - Providing And Fixing, Upvcpipes 6 Kg / Cm2 ( Is: 4985 ) Including All Fittings ( Plain Or Door ) E.G. Bends, Junction, Offsets, Access Pieces, Jointing With Rubber Ring / Solvent Cement Joints Includingrequired Suports, Cutting Chase Or Holes In Walls And Floors And Making Good Where Required.110 Mm Dia Pipe , Phe 26 - Providing & Fixing On Wall Face Unplasticised -Rigid Pvc Rain Water Pipes Conforming To Is:13592 Tyape A Included Jointing With Seal Ring Conforning To Is:5382 Leaving 10 Mm Gap For Thermal Expansion. ( I ) Single Socketed Pipes.110 Mm Diameter , Phe 27 - Providing, Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised - Rigid Pvc Rain Water Pipes Conforming To Is ; 13592 Type A Including Jointing With Seal Ring Conforming To Is ; 5382 Leaving 10 Mm Gap For Thermal Expansion. Coupler -110 Mm Diameter , Phe 28 - Providing, Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised - Rigid Pvc Rain Water Pipes Conforming To Is ; 13592 Type A Including Jointing With Seal Ring Conforming To Is ; 5382 Leaving 10 Mm Gap For Thermal Expansion. Bend -87.5 Deg -110 Mm Diameter , Phe 29 - Providing, Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised - Rigid Pvc Rain Water Pipes Conforming To Is ; 13592 Type A Including Jointing With Seal Ring Conforming To Is ; 5382 Leaving 10 Mm Gap For Thermal Expansion. Shoe -110Mm Shoe , Phe 30 - Providing & Fixing Unplasticised - Pvc Pipe Clips Of Approved Design To Unplasticised - Pvc Rain Water Pipes By Means Of 50X50x50mm Hard Wood Plugs, Screwed With .M.S. Screws Of Required Length Including Cutting Brick Work And Fixing In Cement Mortar 1:4 ( 1Cement : 4 Coarse Sand ) And Making Good The Wall Etc. Complete.110 Mm Dia , Phe 31 - Providing And Fixing Cpvc Pipes Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipe With Clamps At 1.00 Mt Spacing. This Includes Jionting Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge. 20 Mm Nominal Outer Dia Pipes , Phe 32 - Providing And Fixing Of Gun Metal Gate Valve With Ci Wheel Of Approved Quality ( Screwed Ends ) 25Mm Dia, Nominal Bore , Phe 33 - Providing And Fixing Of Gun Metal Gate Valve With Ci Wheel Of Approved Quality ( Screwed Ends ) 32 Mm Dia, Nominal Bore , Phe 34 - Providing And Fixing Gun Metal Non- Return Valve Of Approved Quality ( Pn 1.6 ) 40 Nominal Bore , Phe 35 - Providing And Fixing Brass Stop Cock Of Approved Quality15mm Nominal Bore , Phe 36 - Butterfly Valve ( Manual ) With C I Body Ss Disc, Nitrile Rubber Seal & O- Ring Pn 16 Pressure Rating For Chilled Water / Hot Eater Circulation As Specified 65 Nominal Bore , Phe 37 - Butterfly Valve ( Manual ) With C I Body Ss Disc, Nitrile Rubber Seal & O- Ring Pn 16 Pressure Rating For Chilled Water / Hot Eater Circulation As Specified80 Nominal Bore , Phe 38 - Providing And Fixing Ball Valve ( Brass ) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete25 Mm Nominal Bore , Ex. Phe 1 - Providing And Fixing C.I. Double Acting Air Valve Of Approved Quality With Bolts, Nuts, Rubber Insertions Etc. Complete ( The Tail Pieces, Tapers Etc If Required Will Be Paid Separately ) :50 Mm Dia , Ex. Phe 2 - Providing And Fixing C.I. Double Acting Air Valve Of Approved Quality With Bolts, Nuts, Rubber Insertions Etc. Complete ( The Tail Pieces, Tapers Etc If Required Will Be Paid Separately ) :80 Mm Dia , Ex. Phe 3 - Providing And Fixing C.I. Double Acting Air Valve Of Approved Quality With Bolts, Nuts, Rubber Insertions Etc. Complete ( The Tail Pieces, Tapers Etc If Required Will Be Paid Separately ) :100 Mm Dia , Ex. Phe 4 - Providing & Fixing C.I.Sluice Valve ( With Cap ) Complete With Bolts, Nuts, Rubber Insertions Etc. ( The Tail Pieces If Required Will Be Paid Separately ) 100 Mm Dia.Pipe , Ex. Phe 5 - Providing & Fixing C.I.Sluice Valve ( With Cap ) Complete With Bolts, Nuts, Rubber Insertions Etc. ( The Tail Pieces If Required Will Be Paid Separately ) 150 Mm Dia.Pipe , Ex. Phe 6 - Providing 250Mm Wide Brick Drain In Cement Mortar ( 1:6 ) With Av. 150Mm.Clear Depth And 250Mm Apron Including Cost Of E / W. Involved With 75Mmcement Concrete ( 1:4:8 ) Over One Brick Designation 100-A Flat Soling Inproper Grade And Slope At The Base.The Drain Duly.Plastered In Cm. ( 1:3 ) With Punning Over Exposed Surface All Complete As Per Buildingspecification And Direction Of E / L, , Ex. Phe 7 - Excavating Trenches Of Required Width For Pipes, Cables Etc. Including Excavation For Sockets And Dressing Of Sides, Ramming Of Bottom Depth Upto 1.5 M Including Getting Out The Excavated Soil ( Hard Or Soft ) And Then Returning The Soil As Required In Layers Not Exceeding 20 Cms In Depth Including Consolidating Each Deposited Layer By Ramming, Watering Etc. And Disposing Of Surplus Excavated Soil As Directed Within A Lead Of 50M. [ Hard / Dense Soil ] Pipes, Cables Etc.Exceeding 80Mm Dia.But Not Exceeding 300Mm Dia. , Ex. Phe 8 - Excavating Trenches Of Required Width For Pipes, Cables Etc. Including Excavation For Sockets And Dressing Of Sides, Ramming Of Bottom Depth Upto 1.5 M Including Getting Out The Excavated Soil ( Hard Or Soft ) And Then Returning The Soil As Required In Layers Not Exceeding 20 Cms In Depth Including Consolidating Each Deposited Layer By Ramming, Watering Etc. And Disposing Of Surplus Excavated Soil As Directed Within A Lead Of 50M. [ Hard / Dense Soil ] Pipes, Cables Etc.Exceeding 80Mm Dia. Exceeding 300Mm Dia. , Ex. Phe 9 - Providing And Laying Non-Pressure Np2 Class ( Light Duty ) Rcc Pipes With Collars Jointed With Stiff Mixture Of Cement Mortar In The Proportion Of 1:2 ( 1 Cement : 2 Fine Sand ) Including Testing Of Joints Etc. Complete. ( For Storm Drainage ) 250 Mm Dia Rcc Pipe , Ex. Phe 10 - Providing And Laying Non-Pressure Np2 Class ( Light Duty ) Rcc Pipes With Collars Jointed With Stiff Mixture Of Cement Mortar In The Proportion Of 1:2 ( 1 Cement : 2 Fine Sand ) Including Testing Of Joints Etc. Complete. ( For Storm Drainage ) 300 Mm Dia Rcc Pipe , Ex. Phe 11 - Providing And Laying Non-Pressure Np2 Class ( Light Duty ) Rcc Pipes With Collars Jointed With Stiff Mixture Of Cement Mortar In The Proportion Of 1:2 ( 1 Cement : 2 Fine Sand ) Including Testing Of Joints Etc. Complete. ( For Storm Drainage ) 450 Mm Dia Rcc Pipe , Ex. Phe 12 - Inside Size 120X90 Cm And 90 Cm Deep Including C.I. Cover With Frame ( Medium Duty ) 500 Mm Internal Diameter, Total Weight Of Cover And Frame To Be Not Less Than 116 Kg ( Weight Of Cover 58 Kg And Weight Of Frame 58 Kg ) :With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 , Ex. Phe 13 - Providing And Fixing Square Mouth Sw Gully Trap Grade ‘A’ Complete Ci Grating Brick Masonry Chamber With Bricks Of Class Designation 75 And Water Tight Ci Cover With Frame Of 300 X 300 Mm Size ( Inside ) The Weight Of Cover To Be Not Less Than 13.00 Kg And Frame To Be Not Less Than 5 Kg. As Per Standard Design. ( Cover Min. 4.5 Kg & Frame Min.2.7 Kg ) 180X150 Mm Size P Type With Fps Bricks , Ex. Phe 14 - Constructing Masonry Chamber 30X30x50 Cm, Inside With 75 Class Designation Brick Work In Cement Mortar 1:4 ( 1 Cement:4 Coarce Sand ) For Stop Cock Complete With C.I. Surface Box 100X100x75mm ( Inside ) With Locking Arrangement And Rcc Top Slab 1:2:4 Mix ( 1 Cement : 2 Corase Sand: 4 Graded Stonr Aggregate 20Mm Nominal Size ) Necessary Excavation Foundation Concret 1:5:10 ( 1 Cement:5 Fine Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size ) And Inside Plastering With Cement Mortor 1:3 ( 1 Cement : 3 Coarse Sand ) 12 Mm Thick Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design. , Ex. Phe 15 - Constructing Masonry Chamber 60X60x75 Cm, Inside With 75 Class Designation Brick Work In Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) For Sluice Valve, With C.I. Surface Box 100 Mm Top Diameter, 160 Mm Bottom Diameter And 180 Mm Deep ( Inside ) With Channel Lid And Rcc Top Slab 1:2:4 Mix ( 1 Cement: 2 Coarse Sand: 4 Graded Stone Sggregate 20 Mm Nominal Size ) Necessary Excavation Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) 12 Mm Thick Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design:With F.P.S. Bricks , Ex. Phe 16 - Structual Steel Work Welded In Built Up Sections, Trusses And Framed Work Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. , Ex. Phe 17 - Making Connection Of Gi Distribution Branch With Gi Main Of 50-80Mm Nominal Bore By Providing And Fixing Tee, Including Cutting And Threading The Pipe Etc. Complete. , Rain Water Harvesting 1 - Boring / Drilling Bore Well Of Required Dia For Casing / Strainer Pipe, Bysuitable Method Prescribed In Is:2800 ( Part I ) , Including Collecting Sample From Different Strata , Preparing And Submitting Strata Chart / Bore Log, Including Hire & Running Charges Of All Equipments, Tools, Plants & Machineries Required For The Job, All Complete As Per Direction Of Engineer-In-Charge, Upto 90M Depth Below Ground Level.300 Mm Dia , Rain Water Harvesting 2 - Supplying, Assembling, Lowering And Fixing In Vertical Position In Bore Well, Unplasticized Plc. Medium Well Casing ( Cm ) Pipe Of Required Dia, Conforming To Is: 12818, Including Required Hire & Labour Charges, Fittings & Accessories, All Complete, For All Depths, As Per Director Of Engineer-In-Charge.150Mm Nominal Size Dia , Rain Water Harvesting 3 - Supplying, Assembling, Lowering And Fixing In Vertical Position In Bore Well, Unplasticized Plc. Medium Well Screen ( Rms ) Pipes With Ribs, Conforming To Is: 12818, Including Required Hire & Labour Charges, Fittings & Accessories, All Complete, For All Depths, As Per Director Of Engineer-In-Charge.150 Mm Nominal Size Dia , Rain Water Harvesting 4 - Supplying, Filling, Spreading & Levelling Stone Boulders Of Size Range 5Cm To 20Cm, In Recharge Pit, In The Required Thickness, For All Leads & Lifts, All Complete As Per Direction Of Engineer-In-Charge. , Rain Water Harvesting 5 - Supplying, Filling, Spreading & Levelling Gravel Of Size Range 5Mm To 10Mm, In Recharge Pit, Over The Existing Layer Of Boulders, In Required Thickness, For All Leads & Lifts, All Complete As Per Direction Of Engineer-In-Charge. , Rain Water Harvesting 6 - Supplying, Filling, Spreading & Levelling Coarse Sand Of Size Range 1.5Mm To 2Mm, In Recharge Pit, In Required Thickness Over Gravel Layer, For All Leads & Lifts, All Complete As Per Direction Of Engineer-In-Charge. , Rain Water Harvesting 7 - Providing And Fixing Bail Plug / Bottom Plug Of Required Dia To The Bottom Of Pipe Assembly Of Tube Well As Per Is:2800 ( Part I ) . 100 Mm Dia , Rain Water Harvesting 8 - Making Soak Pit 2.5 M Diameter 3.0 Metre Deep With 45 X 45 Cm Dry Brick Honey Comb Shaft With Bricks And S.W. Drain Pipe 100 Mm Diameter, 1.8 M Long Complete As Per Standard Design. With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 , Rain Water Harvesting 9 - Constructing Soak Pit 1.20X1.20X1.20 M Filled With Brickbats Including S.W. Drain Pipe 100 Mm Diameter And 1.20 M Long Complete As Per Standard Design. With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 , Tubewell 1 - Boring / Drilling Bore Well Of Required Dia For Casing / Strainer Pipe, Bysuitable Method Prescribed In Is:2800 ( Part I ) , Including Collecting Sample From Different Strata , Preparing And Submitting Strata Chart / Bore Log, Including Hire & Running Charges Of All Equipments, Tools, Plants & Machineries Required For The Job, All Complete As Per Direction Of Engineer-In-Charge, Upto 90M Depth Below Ground Level.300 Mm Dia , Tubewell 2 - Supplying, Assembling, Lowering And Fixing In Vertical Position In Bore Well, Unplasticized Plc. Medium Well Casing ( Cm ) Pipe Of Required Dia, Conforming To Is: 12818, Including Required Hire & Labour Charges, Fittings & Accessories, All Complete, For All Depths, As Per Director Of Engineer-In-Charge.150Mm Nominal Size Dia , Tubewell 3 - Supplying, Assembling, Lowering And Fixing In Vertical Position In Bore Well, Unplasticized Plc. Medium Well Casing ( Cm ) Pipe Of Required Dia, Conforming To Is: 12818, Including Required Hire & Labour Charges, Fittings & Accessories, All Complete, For All Depths, As Per Director Of Engineer-In-Charge.100Mm Nominal Size Dia , Tubewell 4 - Supplying, Assembling, Lowering And Fixing In Vertical Position In Bore Well, Unplasticized Plc. Medium Well Screen ( Rms ) Pipes With Ribs, Conforming To Is: 12818, Including Required Hire & Labour Charges, Fittings & Accessories, All Complete, For All Depths, As Per Director Of Engineer-In-Charge.100 Mm Nominal Size Dia , Tubewell 5 - Supplying, Filling, Spreading & Levelling Stone Boulders Of Size Range 5Cm To 20Cm, In Recharge Pit, In The Required Thickness, For All Leads & Lifts, All Complete As Per Direction Of Engineer-In-Charge. , Tubewell 6 - Providing And Fixing Bail Plug / Bottom Plug Of Required Dia To The Bottom Of Pipe Assembly Of Tube Well As Per Is:2800 ( Part I ) . 100 Mm Dia , Submersible Pump - 35M Deep Boring With Casing And Pipe. Supply Of Pipe Etc Supplying & Installation Of Suitable 2Hp Submersible Pump B.S Or K.S.Bor Equivalent Make With Finolex Cable 1X3x2.5 Squmm ( Upto 50Mtr ) Withflexible Conduit 25Mm Dia, Electrical Out Door Pannel With Required Electrical Fitting Such As Mcb Of 0-25Amp ( Havell Or Indocopp Or Mds Make ) , Volt & Ampere Meter ( Ae Make ) , Single Phase Preventer ( Minilac Or Vsp -1 Make ) Starter ( L&T Or Bch Make ) Etc Of Approved Make, 40Mm Hdpe Pipe ( 25 Mtr ) And All Accessories Complete As Per Requirement Of Site. , Water Purifier And Cooler 1 - Fitting And Fixing Single Faucet Storage Type Water Cooler ( Size 461 Mm Wide X 582 Mm Deep X 1217 Mm Height, Weight 46 Kg ) Fully Stainless Body Having Storage Capacity Of 40 Ltrs, Cooling Capacity Of 40 Ltrs. / Hr. With Hermetic Type Compressor, Gas Cooled Motor Equipped With Over Load Protector, Condensor For Propeller Type, Thermostat Autometically Controlled Temperature, Refrigerent R -22, 230 Volt, Single Phase 50 Hertz, Maximum Current 2.3 Amp Including Plug Top And Electrical Lead Wire Connection Upto 3 Metres From The Cooler, Water Inlet And Drain Out Connections Complete In All Respects Of Voltas Model No 40 / 40 Tushar Pss Type Or Similar Type Of Approved Make. , Water Purifier And Cooler 2 - Fitting And Fixing Water Purifier For Drinking Purpose Of Capacity 6 Litres / Min, 5 Purification System With Reverse Osmosis System With Ultra Ventilated Membrane, Tds500 To 2000 Mgl / Ppm, Auto Shut Off With Microswitch Float Manual Flush Facility, Tds Reduction 90% Having Automatic Backwash System With Filteration Unit Along With All Accessories Including Plug Top And Electrical Lead Wire Connection Upto 3 Metres From The Purifier, Water Inlet And Drain Out Connections Complete In All Respects Similar To Aquaguard Or Similar Approved Make - ( Model - Aquasure Elegant Ro Water Purifier Of Size Width 360 Mm X Height - 430 Mm X Depth 235 Mm And Weight 8.5 Kg ) . , Fire Extinguisher-1 - Providing And Fixing Carbon-Di-Oxide Type Fire Extinguishers Consisting Of Welded M.S. Cylindericalbody, Squeeze Lever Discharge Valve Fitted With Pressure Indicating Guage Internal Discharge Tube 30 Cms Long High Pressure Discharge Hose, Discharge Nozzle, Suspension Bracket Conforming To Is:15683 Finished Externally With Red Enamel Paint And Fixed To Wall With Brackets Complete With Internal Charge. Capacity 4.5 Kg. , Fire Extinguisher-2 - Providing And Fixing Abc Powder Type Fire Extinguishers Consisting Of Welded M.S. Cylindericalbody, Squeeze Lever Discharge Valve Fitted With Pressure Indicating Guage Internal Discharge Tube 30 Cms Long High Pressure Discharge Hose, Discharge Nozzle, Suspension Bracket Conforming To Is:15683 Finished Externally With Red Enamel Paint And Fixed To Wall With Brackets Complete With Internal Charge.Capacity 6.0 Kg. , Electrical 1 - Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bellpoint With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductorsingle Core Cable In Surface / Recessed Steel Conduit, Withmodular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. Group C , Electrical 2 - Wiring For Twin Control Light Point With 1.5 Sq.Mm Frls Pvcinsulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, 2 Way Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Electrical 3 - Wiring For Group Controlled ( Looped ) Light Point / Fan Point / Exhaust Fan Point / Call Bell Point ( Without Independent Switch Etc. ) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulatedcopper Conductor Single Core Cable Etc. As Required. Group C , Pvc Conduit 1 - Supplying And Fixing Of Following Sizes Of Medium Class 20Mmpvc Conduit Along With Accessories In Surface / Recessincluding Cutting The Wall And Making Good The Same Incase Of Recessed Conduit As Required. , Pvc Conduit 2 - Supplying And Fixing Of Following Sizes Of Medium Class 32Mmpvc Conduit Along With Accessories In Surface / Recessincluding Cutting The Wall And Making Good The Same Incase Of Recessed Conduit As Required. , Pvc Conduit 3 - Supplying And Fixing Of Following Sizes Of Medium Class 50Mmpvc Conduit Along With Accessories In Surface / Recessincluding Cutting The Wall And Making Good The Same Incase Of Recessed Conduit As Required. , Electrical 4 - Wiring For Light / Power Plug With 2X4 Sq. Mm Frls Pvcinsulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit Alongwith 1 No. 4 Sq. Mm Frls Pvcinsulated Copper Conductor Single Core Cable For Loop Earthingas Required. , Wiring Frls Pvc Insulated Copper Conductor 1 - 2 X 2.5 Sq. Mm. + 1 X 2.5 Sq. Mm. Earth Wire , Wiring Frls Pvc Insulated Copper Conductor 2 - 2 X 4 Sq.Mm. + 1 X 4 Sq.Mm. Earth Wire , Wiring Frls Pvc Insulated Copper Conductor 3 - 2 X 6 Sq.Mm. + 1 X 6 Sq.Mm. Earth Wire , Wiring Frls Pvc Insulated Copper Conductor 4 - 4 X 6 Sq. Mm + 2 X 6 Sq. Mm Earth Wire , Wiring Frls Pvc Insulated Copper Conductor 5 - 4 X 10 Sq. Mm + 2 X 6 Sq. Mm Earth Wire , Wiring Frls Pvc Insulated Copper Conductor 6 - 4 X 16 Sq. Mm + 2 X 16 Sq. Mm Earth Wire , S / F, Gi Box Along With Modular Base & Cover Plate 1 - 1 Or 2 Module ( 75Mm X 75Mm ) , S / F, Gi Box Along With Modular Base & Cover Plate 2 - 3 Module ( 100Mm X 75Mm ) , S / F, Gi Box Along With Modular Base & Cover Plate 3 - 4 Module ( 125Mmx75mm ) , S / F, Gi Box Along With Modular Base & Cover Plate 4 - 6 Module ( 200Mm X 75Mm ) , S / F, Gi Box Along With Modular Base & Cover Plate 5 - 12 Module ( 200Mmx150mm ) , S / F Modular Switch / Socket On The Existing Modular Plate 1 - 5 / 6 Amps Switch , S / F Modular Switch / Socket On The Existing Modular Plate 2 - 15 / 16 Amp Switch , S / F Modular Switch / Socket On The Existing Modular Plate 3 - 3 Pin 5 / 6 Amp Socket Outlet , S / F Modular Switch / Socket On The Existing Modular Plate 4 - 6 Pin 15 / 16 Amp Socket Outlet , S / F Modular Switch / Socket On The Existing Modular Plate 5 - Telephone Socket Outlet , S / F Modular Switch / Socket On The Existing Modular Plate 6 - Tv Antenna Socket Outlet , S / F Modular Switch / Socket On The Existing Modular Plate 7 - Bell Push , Fan Regulator On The Existing Modular Plate Switch Box - Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. , Call Bell / Buzze - Supplying And Fixing Call Bell / Buzzer Suitable For Single Phase, 230 Volts, Complete As Required. , Electrical 5 - Supplying & Fixing Suitable Size Gi Box Wih Modular Plate And Cover In Front On Surface Or In Recess Including Providing And Fixing 25 A Modular Socket Outlet And 25 A Modular Sp Mcb, “C” Curve Including Connections, Painting Etc. As Required. ( For Ac / Geyser ) , Electrical 6 - Supplying And Drawing Co-Axial Tv Cable Rg-6 Grade, 0.7 Mm Solid Copper Conductor Pe Insulated, Shielded With Fine Tinned Copper Braid And Protected With Pvc Sheath In The Existing Surface / Recessed Steel / Pvc Conduit As Required. , Electrical 7 - Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. , Electrical 8 - Providing And Fixing M.S. Fan Clamp Type I Or Ii Of 16 Mm Dia M.S. Bar, Bent To Shape With Hooked Ends In R.C.C. Slabs Or Beams During Laying, Including Painting The Exposed Portion Of Loop, All As Per Standard Design Complete As Required. , Electrical 9 - Providing And Fixing Circular / Hexagonal Cast Iron Or M.S. Sheet Box For Ceiling Fan Clamp, Of Internal Dia 140 Mm, 73 Mm Height, Top Lid Of 1.5 Mm Thick M.S. Sheet With Its Top Surface Hacked For Proper Bonding, Top Lid Shall Be Screwed Into The Cast Iron / M.S. Sheet Box By Means Of 3.3 Mm Dia Round Headed Screws, One Lock At The Corners. Clamp Shall Be Made Of 12 Mm Dia M.S. Bar Bent To Shape As Per Standard Drawing. , 40A Fp-Isolator - Supplying And Fixing Following Rating, Four Pole, 415 V, Isolator In The Existing Mcb Db Complete With Connections, Testing Andcommissioning Etc. As Required. , Electrical 10 - Supplying And Fixing 20 A, 240 V, Spn Industrial Type Socket Outlet, With 2 Pole And Earth, Metal Enclosed Plug Top Alongwith 20 A C Curve, Sp, Mcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Outlet And Complete With Connections, Testing And Commissioning Etc. As Required. , Electrical 11 - Supplying And Fixing 20 A, 415 V, Tpn Industrial Type Socket Outlet, With 4 Pole And Earth, Metal Enclosed Plug Top Alongwith 20 A C Curve, Tpmcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Out Let And Complete With Connections, Testing And Commissioningetc. As Required. , Electrical 12 - Supplying And Fixing 30 A, 415 V, Tpn Industrial Type Socket Outlet, With 4 Pole And Earth, Metal Enclosed Plug Top Alongwith 30 A C Curve, Tpmcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Out Let And Complete With Connections, Testing And Commissioningetc. As Required. , Electrical 17 - Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 8 Way ( 4 + 24 ) , Double Door , Electrical 18 - Supplying And Fixing Of Following Ways Surface / Recess Mounting, Vertical Type, 415 V, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 A Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs ( But Without Mcbs And Incomer ) As Required . ( Note : Vertical Type Mcb Tpdb Is Normally Usedwhere 3 Phase Outlets Are Required. ) 4 Way ( 4 + 12 ) , Double Door , Electrical 19 - Supplying And Fixing Of Following Ways Surface / Recess Mounting, Vertical Type, 415 V, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 A Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs ( But Without Mcbs And Incomer ) As Required . ( Note : Vertical Type Mcb Tpdb Is Normally Usedwhere 3 Phase Outlets Are Required. ) 8 Way ( 4 + 24 ) , Double Door , Electrical 20 - Supplying And Fixing Cable End Box ( Loose Wire Box ) Suitable For Following Triple Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 Volts, On Surface / Recess, Complete With Testing And Commissioning Etc.As Required. For 8 Way, Double Door Fp Mcbdb , Electrical 21 - Supplying And Fixing Cable End Box ( Loose Wire Box ) Suitable For Triple Pole And Neutral, Sheet Steel, Vertical Mcb Distribution Board, 415 V, On Surface / Recess, Complete With Testing And Commissioning Etc. As Required. , 25 A, Rccb - Supplying And Fixing Following Rating, Double Pole, ( Single Phase And Neutral ) , 240 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. , 40 A, Rccb - Supplying And Fixing Following Rating, Double Pole, ( Single Phase And Neutral ) , 240 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. , Single Pole Mcb - Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. , Triple Pole Mcb - Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. , 40A Tp Mcb - Supplying And Fixing 40 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40A Tp Mcb , 40A 4P Mcb - Supplying And Fixing Of Following Mcbs, 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Offollowing Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40A Fp Mcb , 63A 4P Mcb - Supplying And Fixing Of Following Mcbs, 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Offollowing Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. , 100A 4P Mcb - Supplying And Fixing Of Following Mcbs, 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Offollowing Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. , L / F Pvc Sheathed / Xlpe Power Cable In Trench 1 - Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size Direct In Ground Including Excavation, Sand Cushioning, Protective Covering And Refilling The Trench Etc As Required. Above 95 Sq. Mm And Upto 185 Sq. Mm , L / F Pvc Sheathed / Xlpe Power Cable In Trench 2 - Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size Direct In Ground Including Excavation, Sand Cushioning, Protective Covering And Refilling The Trench Etc As Required. Above 185 Sq. Mm And Upto 400 Sq. Mm , L / F Pvc Sheathed / Xlpe Power Cable Over Cable Tray - Above 35 Sq. Mm And Upto 95 Sq. Mm ( Clamped With 25X3mm Ms Flat Clamp ) , S / M End Termination With Brass Compression Gland And Aluminium Lugs Aluminium Conductor Cable Of 1.1 Kv Grade 1 - 3.5C X 185 Sqmm, Aluminium Conductor Cable A2xfy , S / M End Termination With Brass Compression Gland And Aluminium Lugs Aluminium Conductor Cable Of 1.1 Kv Grade 2 - 3.5C X 150 Sqmm, Aluminium Conductor Cable A2xfy , S / M End Termination With Brass Compression Gland And Aluminium Lugs Aluminium Conductor Cable Of 1.1 Kv Grade 3 - 4C X 35 Sqmm Aluminium Conductor Cable A2xfy , Cable Tray 1 - Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray ( Galvanisation Thickness Not Less Than 50 Microns ) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc. As Required. 100 Mm Width X 50 Mm Depth X 1.6 Mm Thickness , Cable Tray 2 - Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray ( Galvanisation Thickness Not Less Than 50 Microns ) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc. As Required. 300 Mm Width X 50 Mm Depth X 1.6 Mm Thickness , Cable Tray 3 - Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray ( Galvanisation Thickness Not Less Than 50 Microns ) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc. As Required. 600 Mm Width X 62.5 Mm Depth X 2.0 Mm Thickness , Cable Tray “Bends” 1 - Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray “Bends” ( Galvanisation Not Less Than 50 Microns ) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc. As Required.100 Mm Width X 50 Mm Depth X 1.6 Mm Thickness , Cable Tray “Bends” 2 - Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray “Bends” ( Galvanisation Not Less Than 50 Microns ) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc. As Required.300 Mm Width X 50 Mm Depth X 1.6 Mm Thickness , Cable Tray “Bends” 3 - Supplying And Installing Following Size Of Perforated Hot Dipped Galvanised Iron Cable Tray “Bends” ( Galvanisation Not Less Than 50 Microns ) With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With G.I. Suspenders Including G.I. Bolts & Nuts, Etc. As Required.600 Mm Width X 62.5 Mm Depth X 2.0 Mm Thickness , Mv Cable 1 - Supplying Following 1.1Kv Grade, Xlpe Insulated, Frls Type, Heavy Duty Armoured Cables Suitable For 415V, 50Hz, Ac System, With Inner And Outer Pvc Sheath, Outer Sheath Provided With Frls Insulation, Galvanised Steel Armouring ( Round ( W ) Or Flat ( F ) As Mentioned ) And With All Components As Mentioned , Specifications, Complete As Required.3.5C X 185 Sqmm, Aluminium Conductor Cable A2xfy , Mv Cable 2 - Supplying Following 1.1Kv Grade, Xlpe Insulated, Frls Type, Heavy Duty Armoured Cables Suitable For 415V, 50Hz, Ac System, With Inner And Outer Pvc Sheath, Outer Sheath Provided With Frls Insulation, Galvanised Steel Armouring ( Round ( W ) Or Flat ( F ) As Mentioned ) And With All Components As Mentioned , Specifications, Complete As Required.3.5C X 150 Sqmm, Aluminium Conductor Cable A2xfy , Mv Cable 3 - Supplying Following 1.1Kv Grade, Xlpe Insulated, Frls Type, Heavy Duty Armoured Cables Suitable For 415V, 50Hz, Ac System, With Inner And Outer Pvc Sheath, Outer Sheath Provided With Frls Insulation, Galvanised Steel Armouring ( Round ( W ) Or Flat ( F ) As Mentioned ) And With All Components As Mentioned , Specifications, Complete As Required. 4C X 35 Sqmm Aluminium Conductor Cable A2xfy , Earthing 1 - Earthing With G.I. Earth Pipe 4.5 Metre Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal / Coke And Salt As Required. , Earthing 2 - Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal / Coke And Salt As Required. , Earthing 3 - Earthing With Copper Earth Plate 600 Mm X 600 Mm X 3 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal / Coke And Salt As Required. , Earthing 4 - Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface / Recessed Conduit / Submain Wiring / Cable As Required. , Earthing 5 - Providing And Fixing 25 Mm X 5 Mm G.I. Strip On Surface Or In Recess For Connections Etc. As Required. , Earthing 6 - Providing And Fixing 25 Mm X 5 Mm Copper Strip On Surface Or In Recess For Connections Etc. As Required. , Earthing 7 - Providing And Fixing 25 Mm X 5 Mm G.I. Strip In 40 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Nut, Bolt, Spring, Washer Excavation And Re-Filling Etc. As Required. , Earthing 8 - Providing And Fixing 25 Mm X 5 Mm Copper Strip In 40 Mm Dia G.I. Pipe From Earth Electrode Including Connection With Brass Nut, Bolt, Spring, Washer Excavation And Re-Filling Etc. As Required. , Earthing 9 - Providing And Fixing Earth Bus Of 50 Mm X 5 Mm Copper Strip On Surface For Connections Etc. As Required. , Earthing 10 - Providing And Fixing Earth Bus Of 50 Mm X 5 Mm Gi Strip On Surface For Connections Etc. As Required. , Fiting & Fixtures 1 - Supply And Installation Of Regular / Standard Model A.C. Ceiling Fan Of 1400 Mm Sweep Including Wiring The Down Rods Of Standard Length ( Upto 30 Cm ) With 1.5 Sq. Mm Fr Pvc Insulated Copper Conductor Etc As Required. , Fiting & Fixtures 2 - Supplying And Fixing Single Wall Mounted 18 / 22 Watt Led Type Batten Fitting Complete With Electronic Driver And Led Tube Etc Directly On Wall / Ceiling Includingconnections With 1.5 Sq.Mm Fr Pvc Insulated Copper Conductor And Earthing The Body Etc. As Required. , Fiting & Fixtures 3 - Supply Installation And Comissioning Ofintegrated Batten Made ( 2Ft ) Of Ultra Slim Co-Extruded Polycarbonate Channel With Housing Part In White Finish & Diffuser Part In Reeded Opal Finish.White Finish Abs End Caps With Decorative Circular Coloured Polycarbonate Cap Snap Fitted On The End Cap To Enhance The Aesthetic Of The Fixture. These End Caps Are Snap-Fitted To The Fixture.High Efficiency Long Life Led With Lumen Efficacy Of 130 Lm / W With Viewing Angle Of 120º.Powered By An Integral Isolated Low Thd Electronic Led Driver ( Smps Based Constant Current Supply ) With Output Short Circuit Protection, Surge Protection.Can Be Fixed Directly Into The Wall / Ceiling , Fiting & Fixtures 4 - Supplying And Fixing Recess Mounted 12 Watt Led Vertical Downlighter Complete With All Accessories And Replaceable Electronic Driver, Directly On False Ceilingincluding Connection With 1.5 Sq.Mm Fr Pvc Insulated Copper Conductor Cable And Earthing The Body Etc. As Required. , Fiting & Fixtures 5 - Supplying And Fixing Recess Mounted 18 Watt Led Vertical Downlighter Complete With All Accessories And Replaceable Electronic Driver, Directly On False Ceilingincluding Connection With 1.5 Sq.Mm Fr Pvc Insulated Copper Conductor Cable And Earthing The Body Etc. As Required. , Fiting & Fixtures 6 - Supply, Installation, Testing And Commissioning Of 400 Mm Sweep, 65W, Blade Material Aluminium Blades , Speed & Oscillation 3 Speed, Pull Cord For Speed And Oscillation.Air Delivery Minimum 72 M³ / Min, Speed Minimun 1350 Revolution Per Minute.Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc. Complete As Required. , Fiting & Fixtures 7 - Supply Installation And Comissioning Of 28W 2X2 Panel Recess Mounting Luminaire With High Performance Leds, Suitable For Mounting With Armstrong / Grid Ceiling.Crca Powder Coated White After Phosphochromate Treatment.High Efficiency Long Life Led Package In Integral Module With Lumen Efficacy Of >100 Lm / W And Viewing Angle Of 120° To Ensure Better Uniformity.Powered By An Independent Isolated, Selv Output Electronic Led Driver ( Smps Based Constant Current Supply ) With Output Short-Circuit Protection, Surge Protection & Other Reliability Test. , Fiting & Fixtures 8 - Supplying Installation Testing & Commissioning Ofb22 Based 9W Led 3 Star Bulb With 850 Lumen, 6K Color Temperature Including Holder. , Fiting & Fixtures 9 - Supplying Installation Testing & Commissioning Of Black Painted Extruded Aluminium Housing. Green / Red Led’S Mounted Inside The Housing. Laser Engraved Signage Matter On Single / Double Acrylic Sheet Fixed On One Side Suitable For Wall / Ceiling / Suspension Type Single / Double Sided Display. In Double Sided Version Black Paper Is Inserted. Ni-Cd Battery Back Up To 2 Hrs. ( Charged Up To 8 - 10 Hrs ) .Mounting Strings Provided For Pendent Mounting Operating Voltage 150-280V Ac Ambient Operating Temperature. – 0 To 450C Ingress Protection – Ip42.Including 3 Core 1.5 Sq.Mm Frls Pvc Insulated And Pvc Sheathed Copper Conductor Cable And Earthing Etc. Up To Suitable Point Complete As Required.220208 Besl 03 Led Ssd Wbb Green 240 3 8Wor220209 Besl 03 Led Ssd Wbb Red 240 3 8Wor220210 Besl 03 Led Dsd Wbb Green 240 3 8Wor220211 Besl 03 Led Dsd Wbb Red 240 3 8W , Fiting & Fixtures 10 - Supply, Installation, Testing And Commissioning Of 600 Mm Sweep, Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current ( Bldc ) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2 Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value ( Cmm / W ) Minimum 6.85, Air Delivery Minimum 135Cmm, 350 Rpm ( Tolerance As Per Is : 374-2019 ) , Thd Less Than 10%, Remote Or Electronic Regulator Unit For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 Degree C ( Max. ) , Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc. Complete As Required. , Civil & Misc Works1 - Providing And Fixing M.V. Danger Notice Plate Of 200 Mm X 150 Mm, Made Of Mild Steel, At Least 2 Mm Thick, And Vitreous Enameled White On Both Sides, And With Inscription In Single Red Colour On Front Side As Required. , Civil & Misc Works2 - Providing And Fixing H.T. Danger Notice Plate Of 250 Mm X 200 Mm, Made Of Mild Steel, At Least 2 Mm Thick, And Vitreous Enameled White On Both Sides, And With Inscription In Single Red Colour On Front Side As Required. , Civil & Misc Works3 - Supplying And Making Cable Route Marker With Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) Of Size 60 Cm X 60 Cm At The Bottom And 50 Cm X 50 Cm At The Top With A Thickness Of 10Cm Including Inscription Duly Engraved As Required. , Civil & Misc Works4 - Supplying And Fixing Cable Route Marker With 10 Cm X 10 Cm X 5 Mm Thick G.I. Plate With Inscription There On, Bolted / Welded To 35 Mm X 35 Mm X 6 Mm Angle Iron, 60 Cm Long And Fixing The Same In Ground As Required. , Civil & Misc Works5 - Providing & Fixing In Position 1000 Mm Wide , Electrical Insulating Rubber Mats As Per Is 15652:2006, 2 Mm Thick, Suitable Up To 1.1 Kv , Fire Retardant, No Effect Of Acids, Alkalis And Transformer Oils, Moisture Proof, High Tensile Strengthandtexture Finish / Cloth Impression ( Anti Slip , Marking On Top ) , Civil & Misc Works6 - Supply & Fixing Shock Treatment Chart Duly Mounted On A Wooden Frame With 5 Mm Thick Glass As Required ( Approx Front Area 1.20 Sq Metre ) , 20 Kvaups - Supplying, Installation, Testing And Commissioningof Online Double Conversion Fully Microprocessor Based , Indoor Type, Compact Ups System Of Following Rating With Igbt Based Pwm Technology To Achieve Thd < 3% And Input Power Factor Of Greater Than 0.95 At 50% Loading, Suitable For Three Phase Ac Input Voltage 380 V To 440 V, 50 Hz +3% / - 3 % And Three Phase Ac Output Voltage 415 ± 1% Volts & Frequency 50 ± 0.5 Hz , Inbuilt Isolation Transformer, Necessary Vrla Batteries Of Suitable Size Having 30 Minutes Back Up Time , Mounting Rack Including And Suitable Size Connecting Cable ( For Ups To Battery And Battery To Battery ) , Static And Maintenance Bypass Switch, Snmp Card For Rs232 / Ethernet Ip Computability For Operation And Monitoring Etc. With All Components As Mentioned , Specifications, Complete As Required.Note : Concerning Vendor Needs To Furnish The Battery Sizing Calculations At The Time Of Ga Approval And Battery Size Has To Be As Per The Approved Ga Drawing. , External Lighting 1 - Supply And Erection Of 4 Metre Height Hot-Dip Galvanized Octagonal Street Light Pole With Following Arm With Top Dia 70 Mm And Bottom Dia A / F 130 Mm, Made Of 3 Mm Thick Sheet Along With Base Plate Of Size 220 X 220 X 12 Mm , Small Door Opening For Junction Box Mounting With Mcb & Connector, Cement Concrete Of 1:3:6 Including Excavation, Refilling And Suitable Size Foundation Bolts With Template And All Complete Jobas Required. ( But Without Pole Collar ) Single Arm , External Lighting 2 - Supplying And Fixing 40 / 45 Watt Led Type Street Light With Die Cast Aluminium Housing For Ingress Protection Of Ip65 And Complete With All Accessories Etc, Onpole / Building Including Connection With Fr Pvc Insulated Copper Conductor Cable And Earthing The Body Etc. As Required. , Transformer - Supplying, Installation Testing And Commissioning Of Following Rating, Distribution Transformer, Suitable For 3 Phase, 50Hz, Ac Supply, Dyn 11 Vector Group, Core Made Of Good Quality Crgo, Windings Made Of Double Wound Copper With Approved Danger And Arc Flash Signages And With All Components As Mentioned , Specifications And Sld And Complete As Required. Power Rating-250 Kva , 11 Kv Ht Dp Structure / Ht Cable 1 - Supplying 11Kv ( Earthed ) Grade, Xlpe Insulated, Heavy Duty Frls Type, Armoured Cables Suitable For 11Kv, 50Hz, Ac System With Inner And Outer Pvc Sheath, Outer Sheath Provided With Frls Insulation, Galvanised Steel Flat Armouring And With All Components As Mentioned In Boq, Specifications And Sld, Complete As Required.3 Core X 240 Sq. Mm , 11 Kv Ht Dp Structure / Ht Cable 2 - Supply, Installation, Testing And Commissioning Of 11 Kv Dp Structure As Per Cei & Hpseb Norms & Comprising Of The Following, But Not Limited To It For Completion Of Worksfor The Followingrsj Pole Of 9.15 Mt Length Of Size 175 X 90 Mm Complete With Suitable M.S. Base Plate Welded At Bottombase Plate - 2 Nos. , Indoor Cable End Termination 2 - Supplying And Making Indoor Cable End Termination With Heat Shrinkable Jointing Kit Complete With All Accessories Including Lugs Suitable For Following Size Of 3 Core, Xlpe Aluminium Conductor Cable Of 11 Kv Grade As Required. 300 Sq. Mm , Outdoor Cable End Termination - Supplying And Making Outdoor Cable End Termination With Heat Shrinkable Jointing Kit Complete With All Accessories Including Lugs Suitable For Following Size Of 3 Core, Xlpe Aluminium Conductor Cable Of 11 Kv Grade As Required. 300 Sq. Mm , Main Lt Panel - Main Lt Panel- ( Refer Sld For Detail ) Supply, Installation, Testing And Commissioning Of Indoor Floor Mounted / Wall Mounted, Ip42 ( Indoor ) And Ip55 ( Outdoor ) , Factory Built, Modular, Sectionalised, Compartmentalized, Extendable Type Lt Cubicle Panel Of Suitable Size Suitable For Operation On 433 / 415 Volts, 50 Hz Ac 3 Phase 4 Wire Supply System Fabricated From Crca Sheet Steel Of 2Mm Thick For , Apfc Panel - Apfc Panel - ( 200 Kvar ) -Outoor Type - ( Refer Sld For Detail ) , Ip Based Cctv System 1 - Sitc Of 2 Megapixel @ 25Fps, H.265 Ip Bullet Camera, 1 / 2.9 Cmos With 2.8~12Mm Varifocal Lens, 0 Lux With Night Vision Ir Up-To 30 Mtrs.Support Intelligent Analytics Like Abnormal Video Signal Detection, Video Mask, Heartbeat, Password Protection. Supports Digital Wdr, Icr, True D / N, 3D Dnr, Roi Coding, Poe, Onvif, Ip66 Etc. Complete As Required. , Cctv 2 - Sitc Of 2 Megapixel @ 25Fps, H.265 Ip Dome Camera, 1 / 2.9 Cmos With 3.6 Fixed Mm 0 Lux With Night Vision Ir Up-To 30 Mtrs.Support Intelligent Analytics Like Abnormal Video Signal Detection, Video Mask, Heartbeat, Password Protection. Supports Digital Wdr, Icr, True D / N, 3D Dnr, Roi Coding, Poe, Onvif, Ip66 Etc. Complete As Required. , Cctv 4 - Sitc Of 32Ch 4K Ivr , H.265 / H.264 • 1080P Real-Time • 4K Display • Dual Lan • 8X Hdd • Raid •Web Plugin Free H.265 / H.264 Compression Technology 4K Display For Clear Monitoring Up To 1080P 16Ch Decoding Ability Smart Search Ii Smart Vca Event Searchsupport Raid 0, 1, 5 Supported To Prevent From Recording Data Loss Browsers Supported: Ie , Smart Functions : Target Count, Electric Fence, Face Detection, Humaniod Detection, Retrograde Detection, Leave Position Detectio Output, Local & Network Backup Etc. Complete As Required. , Cctv 5 - Sitc Of Harddiskdrive8tb, 24 / 7Surveillance Category Only Complete Etc As Required.Etc.All Complete , Cctv 6 - Sitc Of 55 Led Narrow Bazel For Monitoring For Nvr Server Etc. All Complete. , Cctv 7 - Sitc Of Rj-45 Outlets Near The Cameras Etc. All Complete. Etc. All Complete. , Cctv 8 - Sitc Of Cat 6 Patch Cords 1 Meter High Quality Four Pair Twisted Stranded Cable Terminated With Rj45 Modular Plugs At Both The Ends. , Integrated It And Epabx System - Sitcof Cat-6 48 Port Jack Panel For Data As Per Given Specification Etc. All Complete. , Epabx System 2 - Sitcof Cat-6 48 Port Jack Panel For Voice As Per Given Specification Etc. All Complete. , Epabx System 3 - Sitc Of Lszh Cat 6 Speed Unshielded Twisted Pair Computer Cable With 23 Awg Solid Copper Conductors In Existing Concealed / Surface Conduits / Raceways Complete 305 Mtr. Roll As Per Specification Etc. All Complete. , Epabx System 4 - Sitc Of Cat6 Io, Face Plate, Wall Box Combo2- Port Etc. All Complete. , Epabx System 5 - Sitcof Cat-6 Mounting Cords 7 Feet For Data As Per Given Specification Etc. All Complete. , Epabx System 6 - Sitcof Cat 6 Patch Cords 4 Feet For Telephone As Per Given Specification Etc. All Complete. , Epabx System 7 - Sitc Of 24 Port L2 Managed 10 / 100 / 1000 Mbps Non Poe Switch With 4 Sfp Port , For Data Pointsrack Mountable Etc. All Complete. , Epabx System 8 - Sitc Of 24 Port L2 Managed Poe 10 / 100 / 1000 Mbps Switch With 4 Sfp Port , For Cctv Rack Mountable Etc. All Complete. , Epabx System 9 - Sitc Of 24 Port Smart Managed Non Poe With 4 Sfp Port Rack Mountable Etc. All Complete. , Epabx System 10 - Sitc Of 15 U Mountingrack With Ventilation, Sliding Shelves, Power Strips, Etc. All Complete. , Epabx System 11 - Sitc Of Ip Pbx For With 8 Trunk 1 Pri& 8 Digital And 32 Analog Extension Expendble Upto 64 Extesionsy Etc All Complete. , Epabx System 12 - 25 Pair Riser Cable , Epabx System 13 - Mdf Box25 Pair With 20 Pairkrone Module , Epabx System 14 - Supply, Installation, Testing & Commissioning Of Analog Phone With Speaker , Small Display Etc. All Complete. , Epabx System 15 - Client Workstation - Supply, Installation, Testing & Commissioning Of Client Workstation As Per Following Specifications:Intel Core I5-7700K, 4.2Ghz, Os -Genuine Microsoft Microsoft® Windows 10 Enterprise 64 Bit, Ram -16Gb, Memory -500 Gbssd +1Tb Hdd 7200 Rpm Class-Graphic Card - In-Built Processor Graphics ( Gpu ) :Intel® Hd Graphics 630 And Geforce Gtx 970-4Gb- Pcie X 16 Lp Supporting 2 / 4 Monitors., Two ( 2 ) Pci-Express Expansion Slots 2 / 4 Usb, 3.0 Serial, And 2 Hdmi / Vga Adaptor, Cd / Dvd Rom.; Usb Keyboard And Mouse, Ups, Associated Cables Etc. And Other Required Software To Control Nvr In Control Room Including Centralized Video Management Software As Per The Requirement Of The Successful Operation Of The Surveillance System Complete As Required In Accordance With Laid Specification Or Upto The Satisfaction Of Engineer In Charge. , Signage 1 - Providing & Fixing Of Building Direction Signage Mounted On Pole, With Pole Of 100X100mm Shs ( Square Hollow Section ) Of Height Of 5600Mm, And Sign Size Of 900X1050, Sign Made Of Aluminiu C Section Of 60Mm With Internal Framing To Support The Frame In Ms Tubes Hollow Section, Frame Work Duly Painted With Anti-Rust Coatings, With Facia Of 3Mm Thick Exterior Grade Aluminium Composite Panel, Cladded With Uv Cured Digital Printed Retroreflective Sheet Of 3M Make, And Back Panel Of 3Mm Exterior Grade Acp, All Pipes To Be Painted In Approved Color. Cost Shall Includecost Towards Installation, Including Excuvation And Filling Up With Specified Pcc And Fixing Of Foundation Bolts As Specified, Also It Shall Include The Designing Charges.All Complete As Per Direction By Engineer In Charge. , Signage 2 - Providing & Fixing Of Prohibition Sign Silk Screen Printed Of Approved Colors, On Acp Of Exterior Grade, Of Size 300X300mm, All Fixtures In Stainless Steel As Per Design, It Shall Include The Designing Charges .All Complete As Per Direction By Engineer In Charge. , Signage 3 - Providing & Fixing Traffic Regulatory Parking Signage Mounted On Pole, With Pole Of 50X50mm Shs ( Square Hollow Section ) Of Height Of 300Mm, And Sign Size Of 750X750, Sign Made Of Aluminium Sheet Of 3 Mm Thickness With Aluminium Supported Profile To The Frame Of Ms Tube Hollow Section, Aluminium Sheet To Be Cladded With Uv Printed Retroreflective Sheet Of 3M Make Frame Work Duly Painted With Anti Rust Coatings., All Pipe To Be Painted In Apppproved Color. Cost Shall Include Cost Towards Installation, Including Excuvation And Filling Up With Specified Pcc And Fixing Of Foundation Bolts As Specified, Also It Shall Include The Designing Charges.All Complete As Per Direction By Engineer In Charge. , Signage 4 - Providing And Fixing Of Signages Modular Curved Frame Technology Of Various Widths And Lengths To Fometre Suggested Usages Made Of Aluminium Extruded Sections. Duly Anodised All Signages Shall Be Provided With 0.6-0.8Mm Polycarbonate Protecting Film Over The Prints Of Appropriate Size .All Complete As Per Direction By Engineer In Charge , Wall Projected 250X210mm, Both Sides , Signage 5 - Providing And Fixing Of Signages Modular Curved Frame Technology Of Various Widths And Lengths To Fometre Suggested Usages Made Of Aluminium Extruded Sections. Duly Anodised All Signages Shall Be Provided With 0.6-0.8Mm Polycarbonate Protecting Film Over The Prints Of Appropriate Size .All Complete As Per Direction By Engineer In Charge, Door Mounted, 300X80mm , 2 Tr- Air Conditioning 1 - Split Ac ( Inverter Model ) : Supply, Installation, Testing, Commissioning Of Split Type Wall Mounted Air Conditioning Units Of Following Capacity Including Inddor, Outdoor Unit Fitted With Inverter Based Rotary Compressor Fitted With Rotary Compressor, Copper Condensor And First Charge Refrigent R410a / Eco Friendly Green Gas Only, All Complete Including All Electrical Connections To The Electrical Power Supply System Of The Building, Includingbut Not Limited To Supply Of All Electrical Plugs, Etc., As Necessary, Lengthening Of All Electrical Wires Of Ac Units ( Both Indoor And Outdoor ) , Drain Pipe Andincluding Suitable Voltage Stabilisers, Etc. So As To Place Them In A Concealed Manner In The Desired Position. The Copper Pipes And Electrical Cables Shall Be Concealed In Approved Manner And Neatly Run In Straight Lines In A Workman Like Manner With Proper Supports. Complete Supply And Installation Of Split2 Tr Star Rating 3 Star , Refrigerant Piping 1 - Copper Piping: Supply, Installation, Providing, Testing And Commisioning Of Interconnectiong Copper Refrigent Pipe Work ( 19Mm / 13 Mm Thick ) Duly Insulated With Elastomeric Nitrile Rubber, Joints Shall Be Covered With Nitrile Tape Of 3Mm Thick Complete As Per Specification Soft Refrigerant Copper Piping As Per Specifications And Drawings. 25 Mm Od, Wall Thickness >= 1.2 Mm ( Insulation 19 Mm Thick ) , Refrigerant Piping 2 - Copper Piping: Supply, Installation, Providing, Testing And Commisioning Of Interconnectiong Copper Refrigent Pipe Work ( 19Mm / 13 Mm Thick ) Duly Insulated With Elastomeric Nitrile Rubber, Joints Shall Be Covered With Nitrile Tape Of 3Mm Thick Complete As Per Specification Soft Refrigerant Copper Piping As Per Specifications And Drawings. 19.1 Mm Od, Wall Thickness >= 1.0 Mm ( Insulation 13 Mm Thick ) , Refrigerant Piping 3 - Copper Piping: Supply, Installation, Providing, Testing And Commisioning Of Interconnectiong Copper Refrigent Pipe Work ( 19Mm / 13 Mm Thick ) Duly Insulated With Elastomeric Nitrile Rubber, Joints Shall Be Covered With Nitrile Tape Of 3Mm Thick Complete As Per Specification Soft Refrigerant Copper Piping As Per Specifications And Drawings. 15.9 Mm Od, Wall Thickness >= 0.8 Mm ( Insulation 13 Mm Thick ) , Refrigerant Piping 4 - Copper Piping: Supply, Installation, Providing, Testing And Commisioning Of Interconnectiong Copper Refrigent Pipe Work ( 19Mm / 13 Mm Thick ) Duly Insulated With Elastomeric Nitrile Rubber, Joints Shall Be Covered With Nitrile Tape Of 3Mm Thick Complete As Per Specification Soft Refrigerant Copper Piping As Per Specifications And Drawings. 9.5 Mm Od, Wall Thickness >= 0.8 Mm ( Insulation 13 Mm Thick ) , Drain Piping 1 - Providing And Fixing Of Cpvc 6 Kg / Cm2 Drainpiping Complete With Fittings, Supports, 6 Mm Thick Closed Cell Elastomeric Insulation As Per Specifications And Drawings. 20 Mm , Drain Piping 2 - Providing And Fixing Of Cpvc 6 Kg / Cm2 Drainpiping Complete With Fittings, Supports, 6 Mm Thick Closed Cell Elastomeric Insulation As Per Specifications And Drawings. 32 Mm , Main Oxygen Manifold - Supply, Installation, Testing And Commissioning Of Following Gas Manifold System ( Excluding Cylinders ) . The Manifold Is Configured For Designed Numbers Of Cylinders And Is Suitable To Withstand A Pressure Of 145 Kg / Cm2, Along Withhigh-Pressure Copper Annealed Tail Pipes With End Brass Adapter Suitable For Cylinders And Manifold. Top Frame Comprising Of High Pressure Copper Pipes Of Size 1 / 2” Nb X 15Swg With High Pressure Brass Fittings Made Of High Tensile Brass And Connections Through Nonreturn Valves, The Design Of Middle And Bottomframes Is Provided To Fit Both Round And Flat Bottom Cylinders Safely. The Manifold Is Tested ( Hydraulically ) At 3500 Psig. ( It Should Be Ce And Iso 13485 Certified ) Mani Fold- Oxygen Manifold 4 + 4 Cylinder Banks Complete With Nrv, Middle Frame, Bottom Frame With Ce Marked, , Emergency Manifold - Emergency Oxygen Manifold- 01 + 01 Cylinder Emergency Manifold With Complete Regulator, Nrv, Middle Frame & Bottom Frame, , Control Panelfor Oxygen - Fully Automatic Three Port Control Panel For Oxygen Supply, Installation, Testing And Commissioning Of Automatic Manifold Control Panel Would Provide A Duty Or Standby Gas Supply From Two Cylinder Banks With Automaticchangeover The Manifold Indicates Local Status And Has A Remote Indicator Facility. Automaticmanifold Control Panel Would Be Designed To Supply The Mgps With A Constant Pressure Supply Via A Control Panel Form Two Equal Banks Of Cylinders And The Changeover From The , Emergency Manifold Line Regulator - Emergency Manifold Line Regulator Supply, Installation, Testing And Commissioning Of Emergency Manifold Line Regulator I N P U T P R E S S U R E 1 5 0 K G / C M 2 Working Pressure 4 Kg / Cm2 It Should Be Ce And Iso 13485 Certified.Oxygen Input Pressure 150 Kg / Cm2 Working Pressure 4 Kg / Cm2capacity : 1500 Lpm , Cylinderconnectingpipe ( Pig Tail ) - Supply, Installation, Testing And Commissioning Of Cylinder Connecting Pipe ( Pig Tail ) Made Up Of Flexible Ss Hose With Safety Cord 5 / 8 Inch Bsp Gland Nut And One Side 1 / 2 Inch Bsp Internal Threads Having One Meter Length. ( Oxygen -24 , N2o - 10, Co2-4 ) , Backpressurecompensated [ Bpc ] Oxygen Flowmeter - Supply, Installation, Testing And Commissioning Of Back Pressure Compensated [ Bpc ] Oxygen Flow Meter Body Should Be Made Of Brass Material Dully Chrome Plated And Graduated From 0-15 L / M On An Expanded Lower Scale Forprecision Setting At Low Flow And 5-15 L / M For General Use. The Humidifier Bottle Should Be Made Up Of Unbreakable Polycarbonate / Polysulphone Material And Autoclavable At 121 Degree Centigrade Temperature. It Should Be Ceand Iso 13485 Certified. , Oxygen Gas Outletfront Loadeddin / Bsstd - Gas Outlet Front Loaded Din / Bs Std:Supply, Installation, Testing And Commissioning Of Din / British Standard Gas Outlets Are For Use With Medical Gas System. The Gas Outlets Completely Complywith Htm2002 And C11 Standard Regulations And Pass The Test Of Leakage And Connector Stability. Medical Gas Outlet Shall Be Gas Specific For The Services Indicated And Accept Only Corresponding Din / British Standard Quickconnect Adapter. Specifically, Gas Specific Indexed To Eliminate Interchangeability Of Gas Services. The Gas Outlet Is Offered In Consoletype, Wall Type With Box And Hose Barb Type Gas System. It Should Be Ce And Iso 13485Certified. Din / Bis Std. Gas Outlets Feature And Benefits:* Comply With Htm2002 And C11 Standardregulations* Color Coded According To Iso32 Color*100% Pressure And Leak Tested* Full Range Of Mounting Options* Available In Wall Type With Box, Console Typeand Hose Barb Type* Gas Specific Adapters , Quickconnectadapter - Din / British Standard Quick Connect Oxygen Adapter ( Safety Probe ) , Tube - Oxygen H.P. Rubber Tube White Color, , Alarm - Supply, Installation, Testing And Commissioningof Area Pressure Alarm Panel Would Be Witdigital Display, Closed Circuit, Self-Monitoringtype. The Alarm Would Be Designed To Monitorthe Line Pressure In Piping Systems.It Should Be Ce And Iso 13485 Certified. Withfour Digit Notified No. Area Line Pressure Alarm-1 Gases , Isolation Valve, - Supply, Installation, Testing And Commissioning Of The Ball Valves [ For Dividing The Pipelines Into Various Zones For The Case Of Maintenance ] The Internal Ball With Full Borne Is Made Of Stainless Steel With Teflon Seats. These Valves Are Leakproof And Needs Only Quarter Turn For Its Operation [ Either Fully Open Or Fully Closed ] . It Should Be Ce And Iso 13485 Certified.42Mm , Isolation Valve 2 - Supply, Installation, Testing And Commissioning Of The Ball Valves [ For Dividing The Pipelines Into Various Zones For The Case Of Maintenance ] The Internal Ball With Full Borne Is Made Of Stainless Steel With Teflon Seats. These Valves Are Leakproof And Needs Only Quarter Turn For Its Operation [ Either Fully Open Or Fully Closed ] . It Should Be Ce And Iso 13485 Certified 28Mm , Isolation Valve 3 - Supply, Installation, Testing And Commissioning Of The Ball Valves [ For Dividing The Pipelines Into Various Zones For The Case Of Maintenance ] The Internal Ball With Full Borne Is Made Of Stainless Steel With Teflon Seats. These Valves Are Leakproof And Needs Only Quarter Turn For Its Operation [ Either Fully Open Or Fully Closed ] . It Should Be Ce And Iso 13485 Certified 22Mm , Isolation Valve 4 - Supply, Installation, Testing And Commissioning Of The Ball Valves [ For Dividing The Pipelines Into Various Zones For The Case Of Maintenance ] The Internal Ball With Full Borne Is Made Of Stainless Steel With Teflon Seats. These Valves Are Leakproof And Needs Only Quarter Turn For Its Operation [ Either Fully Open Or Fully Closed ] . It Should Be Ce And Iso 13485 Certified 15Mm , Isolation Valve 5 - Supply, Installation, Testing And Commissioning Of The Ball Valves [ For Dividing The Pipelines Into Various Zones For The Case Of Maintenance ] The Internal Ball With Full Borne Is Made Of Stainless Steel With Teflon Seats. These Valves Are Leakproof And Needs Only Quarter Turn For Its Operation [ Either Fully Open Or Fully Closed ] . It Should Be Ce And Iso 13485 Certified 12Mm , Pipeline 1 - Medical Grade Copper Pipeline ( In Mtrs. ) As Per En 13348, 12 Mm ( Od ) X 0.7 Mm Thickness , Pipeline 2 - Medical Grade Copper Pipeline ( In Mtrs. ) As Per En 13348, 15 Mm ( Od ) X 0.9 Mm Thickness , Pipeline 3 - Medical Grade Copper Pipeline ( In Mtrs. ) As Per En 13348, 22 Mm ( Od ) X 0.9 Mm Thickness , Pipeline 4 - Medical Grade Copper Pipeline ( In Mtrs. ) As Per En 13348, 28 Mm ( Od ) X 0.9 Mm Thickness , Pipeline 5 - Medical Grade Copper Pipeline ( In Mtrs. ) As Per En 13348, 42 Mm ( Od ) X 1.2 Mm Thickness , Hospital Sheet Patient Bedtype - Iii With Mattress - Overall Sizes: ( L ) 2268 Mm X ( W ) 922 Mm X ( H ) 610 Mmdescription: Sheet Bed Should Be A Plain Bed Used In The Recovery Ward.Material Specifications: Under Structure Has A Higher Diameter Tubewhich Should Provide A Sturdy Understructure.Lying Surface Area Of Crca , Paediatric Bed With Mattress - Paediatric Bed Of Overall Sizes In Mm: 1500 ( L ) X 850 ( W ) X 1210 ( H ) Flat Single Section Bed With Grille Frame On 4 Sides.Suitable For Children Up To 12 Years.Drop Down Grill Frame On Both Sides For Protection Of The Patient.Material Specifications: Under Structure Has A Higher Diameter Tubewhich Should Provide A Sturdy Understructure.Lying Surface Area Of Crcafinish Specifications: Head Board / Leg Board Should Be Made Of Frame Ms Erw Roundtube Of Sections Ø19, Ø25.4& Ø31.75Mm, Ofthickness1.6 Mmprovision For Mounting Of Iv Pole And Mosquito Net Pole Should Be Presentfinish Specifications: Powder Coating Should Be Bacteriostatic And Thermosetting Epoxy Polyester, Formulated To Fulfill The Requirements For Bacterial Protection.All Powder Coated Parts In Ral White , Bed Side Locker Type I - Over All Dimension :402Mmlx422mm Wx840mm Ht .Locker Should Have One Cabinet And One Drawer Unit .Both Provided With Cam Lock .There Should Be Gap Between Drawer And Unit To Keep General Items For Frequesnt Use Castors Are Provided For Easy Handling .Drawer Made Up Of Crca Sheet 1 Mm Thick And Has Ball Slide For Easy Operation .Top Ss 304 Sheet 0.8 Mm Thick Castors 50 Mmdia , Hamdle Abs ..Powder Coating Of Epoxy Polyester , Medicinetrolleytype -I - Overall Size902mm ( L ) X532mm ( W ) X915mm ( H ) .Top Shelf Should Be Made Of Ss 304 Sheetof 1 Mm Thick. Supporting Legs Made Of Ss304 Tubesection 30.30 Mm Dia.Of 1.2 Mm Thick Provided To Suppoort The Entire Structure.Ss 304 Tube Provided At The Bottom For Placement Of Instument Being Used .Handle Made Up Of Ss 304 Tubeof Dia Dia 16 Mmand Thickness 1.2 Mm Provided To Handle Trolley .And Maneuver Accordingly. High Endurance Anti Static Plastic Injection Moulded Castors Of 125 Mm Dia.Ss Should Be Finished In Glossy Mirror Finish. Max Load Capacity Of 10 Kg / Shelf Udl , Round Stooltype -I - Overall Sizes Diagonal Legdia 538 Mmh470 Min-655Max.Ss 202 Made Sheet With Spin Section Of Thickness 1Mm & Should Be Non Corrosive. It Should Have A Diameter Of 305Mm, Seat Base Is Made Of Ms Ring And Rectangular Tube.En8 Screw Having Dia Of 22 Mm Should Be Used For Height Adjustment Of The Seat Base.The Hub Should Be Made Of Ms Erw Tube Having Dia Of 38Mm And Thickness 2 Mm.The Hub Should Be Welded With The Legs And It Should Accommodate And Cover The Lead Screw Mechanism.The Understructure Should Consist Of 4 Legs Made Up Ofms Erw Tube Of Diameter 25.4 Mm And 1.6Mm Thick. The Press Formed Pipe Leg Should Give A Round & Clean Look. All The Legs Should Be Provided With 4 Nos Of Nylon-6 Bush.All Metal Componentsshould Be Pre Treated With Zinc Phosphating In 9 Tank Process And Then Powder Coated With Anti Microbialepoxy Polyster Powder Coating . All Welding Should Be Co2 Argon Welding To Minimise Rusting On The Welding Areas.Safe Working Load Must Be 135Kg , Strecher On Trolley Type - I - 2005Mm ( L ) X666mm ( W ) X827mm ( H ) .The Trolley Should Be Made Of 31.75 And 25.4 Mm Dia 1.6 Mm Thick Erw Tube.Holder For Stretcher Should Be Made Up Of Mild Steel.Castor Should Be Of 200 Mm Dia , Diagonal Locking Castor.Stretcher Should Be Made Up Oferw Tubeof Dia 25.4 Mm And Thickness 1.6 Mm.Top Sheet Should Be Made Of Crca Sheetof Thickness 1.2 Mm With Contour Shape To Accommodate Patient.Iv Pole Holder Should Be Made Ofms .Maximum Safe Work Load Should Be 135 Kg.To Ensure Qood Quality Welding Co2 ArgonProcess Should Be Adhered To.All Metal Componentsshould Be Pre Treated With Zinc Phosphating In 9 Tank Porcess And Then Powder Coated With Anti Microbialepoxy Polyster Powder Coating.Goods Should Be Supplied In Knocked Down Construction To Reduce Carbon Emission. Performance Test :Proof Loading Test , Cycle Tests , Impact Test, Salt Spray Test, Castor Break Test, The Manufacturer Should Compilant With Iso 9001, 14001, 13485, Ohsas 1800 And Ce Certification. , Doctor Desk Type -X - S / F / F Executive Table Main Desk Should Be Of Dimesion : 1350W X 750D X 750H.The Table Top Should Bein White Cedar, Side Panelsin Black, While The Modestypanel Ina Combination Of Black & White Cedar. Side Panels : ( Black ) Made Form 18Mm Thick Plt With Pvc Lipping.Modesty Panel : Made Form 18Mm Thick Plt With Pvc Lipping. Bigger Upper Panel In Black And Smaller Lower Panel In White Cedar. Made From 18Mm Thick Plt With Pvc Lipping. Mobile Pedestal : One Box And One Filing Drawer With 18Mm Thick Plb Fronts And Top. Handles : Black Powder Coated Die Cast Aluminum Alloy Handles. Mobile Pedestal And Hdu Are Fitted With Central Lock. , Chair Type Iii - S / F / F Executive Chair1 ) Seat / Back Assembly: The Seat And Back Are Made Up Of 1.2 Cm. Thick Hot-Pressed Plywood, Upholstered Withfabric Upholstery Covers And Moulded Polyurethane Foam. The Back Foam Is Designed With Contoured Lumbar Support For Extra Comfort. The Seat Has Extra Thick Foam On Front Edge To Give Comfort To Popliteal Area.High Back Size : 47.5 Cm ( W ) X 69.5 Cm ( H ) Seat Size : 47.0 Cm. ( W ) X 48.0 Cm. ( D ) 2 ) Polyurethane Foam: The Polyurethane Foam Is Moulded With Density = 45 + / -2 Kg / M 3And Hardness = 20 + / - 2At 25% Compression. 3 ) Armrests: The One-Piece Armrests Are Injection Moulded From Black Co-Polymer Polypropylene. 4 ) Center Tilt Synchro Mechanism : The Mechanism Is Designed With The Following Features:· 360 Revolving Type. · Upright Position Locking. · Tilt Tension Adjustment.· Seat / Back Tilting Ratio Of 1:3 ( 60 Seat Tilt / 180 Back Tilt ) . 5 ) Pneumatic Height Adjustment : The Pneumatic Height Adjustment Has Anadjustment Stroke Of 12.0 Cm. 6 ) Telescopic Bellow Assembly : The Bellow Is 3 Piece Telescopic Type And Injection Moulded In Black Polypropylene. 7 ) Pedestal Assembly : The Pedestal Is Injection Moulded In Black 30% Glass-Filled Nylonand Fitted With 5 Nos. Twin Wheel Castors. The Pedestal Is 66.0Cm Pitch-Center Dia. ( 76.0 Cm With Castors. ) 8 ) Twin Wheel Castors : The Twin Wheel Castors Are Injection Moulded In Black Nylon. , Staff Chair Type I - Chair Of Over All Size: 58.0Cm ( W ) X 56.5Cm ( D ) X 87.5Cm ( H ) & 48.0Cm ( Sh ) Seat / Back Assembly: The Seat And Back Are Made From Chemically Treated And Seasoned Wood, Upholstered With Plywood, Black Leather-Cloth, And U-Foam.*Back Size: 46.0Cm ( W ) X 27.0Cm ( H ) .*Seat Size: 46.0Cm ( W ) X 40.0Cm ( D ) .Armrest Tube: The Armrest Tube Is Made Of M.S. E.R.W. Tube Dia. 2.54Cm. ( 1” ) X 16Bg Thick And Powder Coated.Armrest: The Armrest Is Gas-Assisted Injection Moulded From Black Polypropylene.Understructure Assembly: The Understructure Assembly Is A Cantilever Type Frame Made Of Dia. 2.54Cm. ( 1” ) X 14Bg. Thick M.S. E.R.W. Tube And Powder Coated. , Visiter Chair Type V - S / F / F Visitor Chair1 ) Seat / Back Assembly: The Seat And Back Are Made Up Of 1.2 Cm. Thick Hot-Pressed Plywood, Upholstered With Fabric Upholstery Covers And Moulded Polyurethane Foam. The Back Foam Is Designed With Contoured Lumbar Support For Extra Comfort. The Seat Has Extra Thick Foam On Front Edge To Give Comfort To Popliteal Area. Mid Back Size : 47.5 Cm. ( W ) X 58.0Cm. ( H ) Seat Size : 47.0 Cm. ( W ) X 48.0 Cm. ( D ) 2 ) Polyurethane Foam: The Polyurethane Foam Is Moulded With Density = 45 + / -2 Kg / M 3And Hardness = 20 + / - 2At 25% Compression. 3 ) Armrests: The One-Piece Armrests Are Injection Moulded From Black Co-Polymer Polypropylene. 4 ) Tubular Frame : The Powder Coated Tubular Frame Is Cantilever Type & Made Of Dia 25.4Mm X 2Mm Thk M.S. Er.W. Tube. , Wheel Chair Type - I - ( L ) 790 X ( W ) 600 X ( H ) 870Mm.Foldable Frame Structure Should Be Made Of Section 22Diax1.2Mm A3 Carbon Steel With Chrome Finish. Cross Bar Should Be Made Of A3 Carbon Steel With Section 25.4 X 1.2Mm.Rear Wheel:24 Inch Solid Mag Wheels With Alloy In The Rim .Integrated Handrim Provide To Drive The Wheel Chair Of Section 16X1.2Mm A3 Carbon Steel With Chrome Finish.Front Wheel :8 Inch Hub Made Of Pa Polymer And Outer With Solid Rubber.Pu Molded Arm Rest & Base Should Be Made Of Abs For Better Arm Support .Leatherite Strap For Calf Rest & Leatherite Cushion For Seat.Adjustable Alluminimum Die Cast Foot Rest With Updown & Swivel Type Mechanism.Handles Should Be Made Of Moulded Rubber Grip To Push The Wheelchair.Hand Brakes Should Be Provided To Lock The Wheelchair At Desired Location.Foot Pressextended Base With Molded Plastic For Better Grip.Anti Rust Chrome Finsh. Safe Work Load Of100 Kg , Basin Stand Type I - Ht 850 Mm Ss Bowl Ms Tubular Frame Of Dia 25.4 X1.2 Mm Tube Work Mounted On Three 50 Dia.Non Rusting Castors All Without Brack. Ss Part Finished With Matt Polish , Kick Buckettype -I - Overa All Dimension Of The Bucket Should Be 517 Mm ( L ) X 517 Mm ( W ) X 210 Mm H.It Should Made Of 12.7 Mm Dia And 1.6 Mm Thick Ss 304 Ring. The Bowl Should Be Ss Made Of .8 Mm Thck .3 Nos 50 Mm Diahigh Endurance Plasticinjection Moulded Castors Should Be Provided For The Movement.Mx Load Bearing Capacity Should Be 10 Kg. , Instrument Cabinet Type -I - Overall Dimensions Of 900Mmwx 1990Mmhx450mmd And Should Have Transparent Doors And Sides With Steel Frame Work. Transparent Portion Of This Cupboard Should Be Made Of Acrylic Of 4Mm Thick. This Cabinet Should Have 5 Adjustable Acrylic Shelves Each Of 6 Mm Thickness. Three Way Lock Should Be Provided Of 6 Levers. In The Front Door There Should Be 4 Acrylic Sheets And 2 Each On Both The Sides. Metal Used Should Be Of Crca And Powder Coated For Finish. To Be Provided With Rubber Shoes To Prevent Direct Contact Of Cabinet And Floor. , Hospital Curtain Tracks & I.V. Tree System - Supply Installation Testing & Commissioning Of Cubical Tracks System Made Of Powder Coated Aluminium Alloy, Stain Free Polyster Fabric , Water Repellent Curtains , Smooth Movement , Non Sticking Runnner With Stainless Steel Hooks Made From Mirror Finish Stainless Steel , Adjustable Height With All Accessories. Total Quantity : 1