Bids Are invited for Digital Colorimeter - Measuring Modes :%Ot & Abs., Conc. And Kfactor ; Sample Volume: Lml; Display: Lcd ; Light Source : White Led; Eight Optical Filters On A Tumet To Cover 400 _ 700 Nm ; The Wavelength Range Should Be 400-700Nm With 8 Optical Filters With Peak Wavelength: 420Nm, 4 40Nm, 490Nm, 520Nm (Typical) 540Nm, 570{Irn,600Nm, 700Nm; Source :White Led ; Photometric Resolution : O.Lyot & 0.001 Abs Upto 1.999 Abs (O.D.), ; Display:2Line 16 Character Lcd ; K-Factor Range: L To I 999,Concentration:O To 2,; K-Factor Range: L To I 999,Concentration:O To 2,; Power 230Y +L0yo,50Hzaccessories : Set Of 5 Compatible Tubes And Cuvettes , Digital Ph Meter Of Wide Range - Ph Meter Electronic Range : 0 To 14. ; Resolution 0.01. ; Accuracy : ±0.01. ; Repeatability : ±0.01. ; Stability : ±0.05 In 8 Hrs. ; Temperature Compensation : 0-1000C Automatic. ; Readout: 31/2 Digit 7 Segment Led. ; Accessories Supplied : Combined Electrode, Temp, Probe For Atc, Electrode Stand, Three Wide Mouth Plastic Bottle Having One Tablet Each Of 4,7.2, 9.2 Ph, Instruction Manual And Dust Cover ; Power Requirement : 230V ±10%, 50 Hz Electrode, Temp, Probe For Atc , Analytical Balance :Upto 200G/1G Increment - Weighing Capacity- 200Gm ; External Calibration ; Display Lcd ; Minimum Weighing Value – 0.008Gm ; Readibility – 0.001Gm ; Linearity +-0.003G Stabilization Time – 8S , Calibrated Urinometer - Conventional Urinometer ( Preferably Non Mercury Based) , Binocular Microscope Compound - Body: Binocular, Sturdy, Stable Base Body With Focus Adjustment Controls. ; Eye Piece: Paired, High Quality, (The Image Of The Object As Seen Through The Binocular Eyepiece Should Be Well Defined Centrally In At Least 2/3 Field Of View), Achromatic, Wide Field, 10X With Inbuilt Pointer Objective: Three Objectives10x, 40X, 100X. 10X And 40X Objectives Should Have Numerical Apertures Of 0.25 And 0.65 Respectively And Should Be Of; Spring Loaded Type Or Otherwise.100X Should Have Numerical Aperture

Tender Notice

30626558

Indian


Bihta

Bihar

January 25, 2022

Key Value

50 Lakhs

50 Lakhs

50 Lakhs

To Download Tender Document Click on the below link

Bids Are invited for Digital Colorimeter - Measuring Modes :%Ot & Abs., Conc. And Kfactor ; Sample Volume: Lml; Display: Lcd ; Light Source : White Led; Eight Optical Filters On A Tumet To Cover 400 _ 700 Nm ; The Wavelength Range Should Be 400-700Nm With 8 Optical Filters With Peak Wavelength: 420Nm, 4 40Nm, 490Nm, 520Nm (Typical) 540Nm, 570{Irn,600Nm, 700Nm; Source :White Led ; Photometric Resolution : O.Lyot & 0.001 Abs Upto 1.999 Abs (O.D.), ; Display:2Line 16 Character Lcd ; K-Factor Range: L To I 999,Concentration:O To 2,; K-Factor Range: L To I 999,Concentration:O To 2,; Power 230Y +L0yo,50Hzaccessories : Set Of 5 Compatible Tubes And Cuvettes , Digital Ph Meter Of Wide Range - Ph Meter Electronic Range : 0 To 14. ; Resolution 0.01. ; Accuracy : ±0.01. ; Repeatability : ±0.01. ; Stability : ±0.05 In 8 Hrs. ; Temperature Compensation : 0-1000C Automatic. ; Readout: 31/2 Digit 7 Segment Led. ; Accessories Supplied : Combined Electrode, Temp, Probe For Atc, Electrode Stand, Three Wide Mouth Plastic Bottle Having One Tablet Each Of 4,7.2, 9.2 Ph, Instruction Manual And Dust Cover ; Power Requirement : 230V ±10%, 50 Hz Electrode, Temp, Probe For Atc , Analytical Balance :Upto 200G/1G Increment - Weighing Capacity- 200Gm ; External Calibration ; Display Lcd ; Minimum Weighing Value – 0.008Gm ; Readibility – 0.001Gm ; Linearity +-0.003G Stabilization Time – 8S , Calibrated Urinometer - Conventional Urinometer ( Preferably Non Mercury Based) , Binocular Microscope Compound - Body: Binocular, Sturdy, Stable Base Body With Focus Adjustment Controls. ; Eye Piece: Paired, High Quality, (The Image Of The Object As Seen Through The Binocular Eyepiece Should Be Well Defined Centrally In At Least 2/3 Field Of View), Achromatic, Wide Field, 10X With Inbuilt Pointer Objective: Three Objectives10x, 40X, 100X. 10X And 40X Objectives Should Have Numerical Apertures Of 0.25 And 0.65 Respectively And Should Be Of; Spring Loaded Type Or Otherwise.100X Should Have Numerical Aperture