Bids Are Invited For Lab Item 1 , Lab Item 2 , Lab Item 3 , Lab Item 4 , Lab Item 5 , Lab Item 6 , Lab Item 7 , Lab Item 8 , Lab Item 9 , Lab Item 10 , Lab Item 11 , Lab Item 12 , Lab Item 13 , Lab Item 14 , Lab Item 15 , Lab Item 16 , Lab Item 17 , Lab Item 18 , Lab Item 19 , Lab Item 20 , Lab Item 21 , Lab Item 22 , Lab Item23 , Lab Item 24 , Lab Item 25 , Lab Item 26 , Lab Item 27 , Lab Item 28 , Lab Item 29 , Lab Item 30 , Lab Item 31 , Labitem 32 , Lab Item 33 , Lab Item 34 , Lab Item 35 , Lab Item36 , Lab Item 37 , Lab Item 38 , Lab Item 39 , Lab Item 40 Total Quantity : 117-1 Vernier Caliper 2 Screw Gauge 3 Travelling Microscope 4 Tripod Base With Levelling Screws, Height Stand, Measuring Tape, Sextant, Astronomical Telescope, Terrestrial Telescope 5 Fly Wheel Set-Up - ( The Setup Should Consists Of Flywheel ( 200 Mm Diameter ) With Axle Supported On Bearings 2. Hanger 100 G + 9 × 100 G Slotted Weights 3. Stop Watch 4. Vernier Calliper 5. Meter Scale 6. Thread 7. Instruction Manual ) 6 Moment Of Inertia Setup ( Moment Of Inertia Table Setup Should Consists Of 1. Micro Controller Based Measurement Unit. 2. Engraved And Ruled Inertia Discs. 3. Inverted Ushaped Metal Body With Chuck Screw Connection. 4. Measurement Unit Giving Instant Result Of Moment Of Inertia. 5. Three Experimental Bodies. 6. For Time Measurement Of Rotation, Measurement Unit With Manual And Automatic Mode. ) 7 Photoelectric Effect Setup ( The Setup Consists Of Main Unit Having Highly Stabilized Power Supply, Digital Volmeter ( Led 3 Digit , 0-9.99Vdc ) , Digital Micro-Ammeter ( Led 3 Digit , 0-999Uadc ) , Digital Milliammeter ( Led , 3 Digit , 0999Madc ) Light Source ( 3 Colours –White , Blue, Red ) Black Box With Spacers For Distance Variation. ) 8 P-N Junction Kit 9 Pnp / Npn Transistor Kit 10 Mosfet Kit 11 Cro, Function Generator ( Equipment And Technical Data · Frequency Range: 0.1 Hz To 1 Mhz · Steps: 0.1 Hz · Distortion Factor: <0.5% · Signal Forms: Sine, Triangle, Square, Frequency Ramp, Voltage Ramp · Amplifier Output, Short-Circuit-Proof, Via Bnc And 4-Mm Connectors: O Output Voltage : 0 - 20 Vpp For R Out > 40 Ohm O Dc Offset: ±10 V ( Steps 5 Mv ) O Power Output: 5 W ( For Up To 1A ) Where R Out = 20 Ohm · Headphone Output Via 3.5 Mm Jack Socket:O Switch For Selecting Standard O Output Voltage: 0 - 1 Vpp For R Out =400 Ohm. ) 12 He-Ne Laser Source And Diffraction Grating Setup ( He-Ne Laser Source · Output Power: 0.5 Mw – 5 Mw · Wavelength: 632.8Nm · Polarized Or Randomly Polarized Output · Tem00 Mode · Beam Divergence: <1.0 Mrad · Beam Diameter: ≤ 0.7Mm 2. Power Supply ( Input 240 V / 50 Hz ) 3. Optical Bench ( 1.5 Meter ) 4. Reflection Grating ( 15000 Lines Per Inch ) 5. Transmission Grating ( 15000 Lines Per Inch ) 6. Photo Detector With Bnc Connector And Holder 7. Screen ( 12 X 12 ) With Clamp Type Holder 8. Knife Edge With Micrometer Movement 9. Digital Multimeters 10. Scale With Mount ) 13 Optical Fiber Setup ( The Setup Consists Of Laser Diode ( 5Mw, 632Mm ) , Objective ( 10X ) , Fiber ( 1Mtr Long ) , Dectector With Bnc Connector Autoarranging Multimeter, Chucks And Bases ( 2Nos ) To Hold The Components, Screen With Circular Graduations, One Circular Base With Linear And Circular Motion And Optical Bench.Headphones Or Speakers ) 14 Forced Oscillator And Resonance Set Up ( It Should Consists Of Base Unit With Frequency Generator ( Mass Attached To Spring Which Is Connected To A Cord Passing Over A Pully And Further Connected To Drive Wheel ) , Spring Of Known Spring Constant, Scale Attached To Setup, Weight 50G Four Each. ) 15 A Nearly Monochromatic Source Of Light ( Source Of Sodium Light ) , A Plano-Convex Lens C, An Optically Plane Glass Plate P, An Optically Flat Glass Plate G In- Clined At An Angle Of 45◦, A Travelling Microscope With Measuring Scale And A Spherometer. ( Newtons Ring Apparatus- Dimension: 390 X 480 X 170Mm Approx. Micrometer: 0.01 Mm Least Count Eyepiece: Ramsden 10X Objective: 3X Weight: 12.6 Kg Approx. Spherometer- Type: 3 Legs Verticale Scale: 6Mmx6mm ( Wxt ) Micrometer: Dia. 40Mm, Brass Lower Disc: Dia. 60Mm Range: 10-0-10Mm Least Count: 0.01Mm Plano-Convex Lens- Dia. : 61.5Mm, Glass Focal Length : 200Mm ) 16 Dc Power Supply In Following Parts: ( A ) H.T. ( High Tension ) Dc Power Supply ( B ) Dc Power Supply For Solenoid ( C ) Potentiometers ( D ) Two Meters To Measure Acceleration Voltage &Solenoid Current ( E ) Eight Pin Octal Bases, One Long Solenoid , Crt Mounted Inside The Solenoid. ( 1.Dc Power Supply For Apparatus Comprises Of The Following Built In Parts: ( A ) H.T. ( High Tension ) Dc Power Supply Continuously Variable From 375V To 850V±5% For Acceleration Voltage Control. ( B ) Dc Power Supply For Solenoid 0-60Vdc Variable In Steps Through Two Band Switches ( 5 Steps ) Using Fine And Coarse Controls Band Switches. ( C ) Potentiometers Are Mounted On The Front Panel For Focus Control, Intensity Control And X, Y Shift Controls. ( D ) Two Meters To Measure Acceleration Voltage &Solenoid Current Are Mounted On The Front Panel. ( E ) Eight Pin Octal Bases Are Mounted On The Front Panel To Connect The Crt Plug. 2.One Long Solenoid Wound On 4 ̋Dia Pvc With 23 Wire Gauge, Mounted On Wooden Stand & Connections Brought Out At Terminals. 3.Crt Mounted Inside The Solenoid. ) 17 Capacitance And Permittivity Setup ( The Setup Consists Of Reed Relay Switch With It’S A.C. Supply, Integrated Circuit Current Amplifier And 0-100 Micrometer Housed In A Cabinet.Pair Of Capacitor Plates 0.25M X 0.25M X 4 Mm, A Perspex Sheet, Two Capacitors ( 500 Pf Each ) , And Set Of Perspex / Polythene Spacers ) 18 Dielectric Constant Measurement Set-Up ( The Setup Should Consists Of 1. Digital Voltmeter ( 0-99 Vac ) @ 1Khz 2. Audio Oscillator ( 1Khz ) 3. Standard Capacitors ( 2 Nos ) ( In Pf And Nf Range ) 4. Gold Plated Parallel Plate Dielectric Cell-I ( 75Mm ) 5. Gold Plated Parallel Plate Dielectric Cell-Ii ( 25 Mm ) 6. Dielectric Sample For Dielectric Cell-I ( Glass – 2 Nos, Bakellite-1 No, Pcb -1 No ) 7. Dielectric Sample For Dielectric Cell-Ii ( Pzt-2 Nos, Barium Titanate -1 No 25 Mm Diameter With 8. Instruction Manual Complete Unit Should Be Housed In Metal Cabinet Of 416X230x165mm With Effective Electromagnetic Shielding With Proper Connecting Cables. ) 19 Forced Oscillator And Resonance Set Up ( It Should Consists Of Base Unit With Frequency Generator ( Mass Attached To Spring Which Is Connected To A Cord Passing Over A Pully And Further Connected To Drive Wheel ) , Spring Of Known Spring Constant, Scale Attached To Setup, Weight 50G Four Each. ) Refrective Index Setup ( The Set-Up Should Consist Of Spectrometer, Diffraction Grating, Mercury Light Source, Prism, Reading Lens Etc. Spectrometer Standard: 7 Diacircle Reading 30 Seconds. The Used In Telescope And Collimator Has To Be Achromatic And Provided With Rack And Pinion Focusing Arrangement Telescope Arm And Prism Table Are To Be Provided With Fine And Coarse Adjustment. The Prism Table Is Provided With Three 20 Leveling Screws And Is Engraved With Concentric Rings & Lines. The Scales And Verniers Are Of Stainless Steel ) 21 He-Ne Laser Source And Diffraction Grating Setup ( He-Ne Laser Source · Output Power: 0.5 Mw – 5 Mw · Wavelength: 632.8Nm · Polarized Or Randomly Polarized Output · Tem00 Mode · Beam Divergence: <1.0 Mrad · Beam Diameter: ≤ 0.7Mm 2. Power Supply ( Input 240 V / 50 Hz ) 3. Optical Bench ( 1.5 Meter ) 4. Reflection Grating ( 15000 Lines Per Inch ) 5. Transmission Grating ( 15000 Lines Per Inch ) 6. Photo Detector With Bnc Connector And Holder 7. Screen ( 12 X 12 ) With Clamp Type Holder 8. Knife Edge With Micrometer Movement 9. Digital Multimeters 10. Scale With Mount ) 22 Optical Fiber Setup ( The Setup Consists Of Laser Diode ( 5Mw, 632Mm ) , Objective ( 10X ) , Fiber ( 1Mtr Long ) , Dectector With Bnc Connector Autoarranging Multimeter, Chucks And Bases ( 2Nos ) To Hold The Components, Screen With Circular Graduations, One Circular Base With Linear And Circular Motion And Optical Bench. ) 23 Friction Table And Horizental Board ( One Big Table With Clamp And Horizental Board ) 24 Searles Apparatus With Weight Box. ( For Different Weight Measure ) 25 Terminal Velocity Measure Stocks Law Set Up ( Glycerin Stop Watch Bob, Tube Clamp Stand 26 Pullingers Apparatus ( Heet Burner Tripod Stand, Weeker Tube Iron Rode Etc. ) 27 Fortins Barometer 28 Mercury Thermameter ( Mercury Thermameter 0 To 360 C, 300Mm Long ) 29 Ultrasonic Interfero Meter ( Measuring Device For Velocity Of Ultra Sonic ) 30 Plane Mirror Interface 31 Glass Slab ( 75 X 50 X 18 Mm And Glass Prism ( 50 X 50 ) ) 32 Convex Lens ( 2 Convex X 50Mm ) 33 Ohms Law Apparatus ( P=1.5Wp Volt-220V I-250 Ma ) 34 Post Office Box ( Different Resistence Measure ) 35 Kirchoffs Law Verification Kit ( Electrical Curcit ) 36 Capaciter And Kits 37 Galvanometer ( Curcit ( Dc ) 30-30V ) 38 Ammeter 39 Volt Meter 40 Optical Projection System ( Ohp / Lcd For Project Report )

Tender Notice

31449505

Indian


Bihar

March 23, 2022

Key Value

5.39 Lakhs

5.39 Lakhs

5.39 Lakhs

To Download Tender Document Click on the below link

Bids Are Invited For Lab Item 1 , Lab Item 2 , Lab Item 3 , Lab Item 4 , Lab Item 5 , Lab Item 6 , Lab Item 7 , Lab Item 8 , Lab Item 9 , Lab Item 10 , Lab Item 11 , Lab Item 12 , Lab Item 13 , Lab Item 14 , Lab Item 15 , Lab Item 16 , Lab Item 17 , Lab Item 18 , Lab Item 19 , Lab Item 20 , Lab Item 21 , Lab Item 22 , Lab Item23 , Lab Item 24 , Lab Item 25 , Lab Item 26 , Lab Item 27 , Lab Item 28 , Lab Item 29 , Lab Item 30 , Lab Item 31 , Labitem 32 , Lab Item 33 , Lab Item 34 , Lab Item 35 , Lab Item36 , Lab Item 37 , Lab Item 38 , Lab Item 39 , Lab Item 40 Total Quantity : 117-1 Vernier Caliper 2 Screw Gauge 3 Travelling Microscope 4 Tripod Base With Levelling Screws, Height Stand, Measuring Tape, Sextant, Astronomical Telescope, Terrestrial Telescope 5 Fly Wheel Set-Up - ( The Setup Should Consists Of Flywheel ( 200 Mm Diameter ) With Axle Supported On Bearings 2. Hanger 100 G + 9 × 100 G Slotted Weights 3. Stop Watch 4. Vernier Calliper 5. Meter Scale 6. Thread 7. Instruction Manual ) 6 Moment Of Inertia Setup ( Moment Of Inertia Table Setup Should Consists Of 1. Micro Controller Based Measurement Unit. 2. Engraved And Ruled Inertia Discs. 3. Inverted Ushaped Metal Body With Chuck Screw Connection. 4. Measurement Unit Giving Instant Result Of Moment Of Inertia. 5. Three Experimental Bodies. 6. For Time Measurement Of Rotation, Measurement Unit With Manual And Automatic Mode. ) 7 Photoelectric Effect Setup ( The Setup Consists Of Main Unit Having Highly Stabilized Power Supply, Digital Volmeter ( Led 3 Digit , 0-9.99Vdc ) , Digital Micro-Ammeter ( Led 3 Digit , 0-999Uadc ) , Digital Milliammeter ( Led , 3 Digit , 0999Madc ) Light Source ( 3 Colours –White , Blue, Red ) Black Box With Spacers For Distance Variation. ) 8 P-N Junction Kit 9 Pnp / Npn Transistor Kit 10 Mosfet Kit 11 Cro, Function Generator ( Equipment And Technical Data · Frequency Range: 0.1 Hz To 1 Mhz · Steps: 0.1 Hz · Distortion Factor: <0.5% · Signal Forms: Sine, Triangle, Square, Frequency Ramp, Voltage Ramp · Amplifier Output, Short-Circuit-Proof, Via Bnc And 4-Mm Connectors: O Output Voltage : 0 - 20 Vpp For R Out > 40 Ohm O Dc Offset: ±10 V ( Steps 5 Mv ) O Power Output: 5 W ( For Up To 1A ) Where R Out = 20 Ohm · Headphone Output Via 3.5 Mm Jack Socket:O Switch For Selecting Standard O Output Voltage: 0 - 1 Vpp For R Out =400 Ohm. ) 12 He-Ne Laser Source And Diffraction Grating Setup ( He-Ne Laser Source · Output Power: 0.5 Mw – 5 Mw · Wavelength: 632.8Nm · Polarized Or Randomly Polarized Output · Tem00 Mode · Beam Divergence: <1.0 Mrad · Beam Diameter: ≤ 0.7Mm 2. Power Supply ( Input 240 V / 50 Hz ) 3. Optical Bench ( 1.5 Meter ) 4. Reflection Grating ( 15000 Lines Per Inch ) 5. Transmission Grating ( 15000 Lines Per Inch ) 6. Photo Detector With Bnc Connector And Holder 7. Screen ( 12 X 12 ) With Clamp Type Holder 8. Knife Edge With Micrometer Movement 9. Digital Multimeters 10. Scale With Mount ) 13 Optical Fiber Setup ( The Setup Consists Of Laser Diode ( 5Mw, 632Mm ) , Objective ( 10X ) , Fiber ( 1Mtr Long ) , Dectector With Bnc Connector Autoarranging Multimeter, Chucks And Bases ( 2Nos ) To Hold The Components, Screen With Circular Graduations, One Circular Base With Linear And Circular Motion And Optical Bench.Headphones Or Speakers ) 14 Forced Oscillator And Resonance Set Up ( It Should Consists Of Base Unit With Frequency Generator ( Mass Attached To Spring Which Is Connected To A Cord Passing Over A Pully And Further Connected To Drive Wheel ) , Spring Of Known Spring Constant, Scale Attached To Setup, Weight 50G Four Each. ) 15 A Nearly Monochromatic Source Of Light ( Source Of Sodium Light ) , A Plano-Convex Lens C, An Optically Plane Glass Plate P, An Optically Flat Glass Plate G In- Clined At An Angle Of 45◦, A Travelling Microscope With Measuring Scale And A Spherometer. ( Newtons Ring Apparatus- Dimension: 390 X 480 X 170Mm Approx. Micrometer: 0.01 Mm Least Count Eyepiece: Ramsden 10X Objective: 3X Weight: 12.6 Kg Approx. Spherometer- Type: 3 Legs Verticale Scale: 6Mmx6mm ( Wxt ) Micrometer: Dia. 40Mm, Brass Lower Disc: Dia. 60Mm Range: 10-0-10Mm Least Count: 0.01Mm Plano-Convex Lens- Dia. : 61.5Mm, Glass Focal Length : 200Mm ) 16 Dc Power Supply In Following Parts: ( A ) H.T. ( High Tension ) Dc Power Supply ( B ) Dc Power Supply For Solenoid ( C ) Potentiometers ( D ) Two Meters To Measure Acceleration Voltage &Solenoid Current ( E ) Eight Pin Octal Bases, One Long Solenoid , Crt Mounted Inside The Solenoid. ( 1.Dc Power Supply For Apparatus Comprises Of The Following Built In Parts: ( A ) H.T. ( High Tension ) Dc Power Supply Continuously Variable From 375V To 850V±5% For Acceleration Voltage Control. ( B ) Dc Power Supply For Solenoid 0-60Vdc Variable In Steps Through Two Band Switches ( 5 Steps ) Using Fine And Coarse Controls Band Switches. ( C ) Potentiometers Are Mounted On The Front Panel For Focus Control, Intensity Control And X, Y Shift Controls. ( D ) Two Meters To Measure Acceleration Voltage &Solenoid Current Are Mounted On The Front Panel. ( E ) Eight Pin Octal Bases Are Mounted On The Front Panel To Connect The Crt Plug. 2.One Long Solenoid Wound On 4 ̋Dia Pvc With 23 Wire Gauge, Mounted On Wooden Stand & Connections Brought Out At Terminals. 3.Crt Mounted Inside The Solenoid. ) 17 Capacitance And Permittivity Setup ( The Setup Consists Of Reed Relay Switch With It’S A.C. Supply, Integrated Circuit Current Amplifier And 0-100 Micrometer Housed In A Cabinet.Pair Of Capacitor Plates 0.25M X 0.25M X 4 Mm, A Perspex Sheet, Two Capacitors ( 500 Pf Each ) , And Set Of Perspex / Polythene Spacers ) 18 Dielectric Constant Measurement Set-Up ( The Setup Should Consists Of 1. Digital Voltmeter ( 0-99 Vac ) @ 1Khz 2. Audio Oscillator ( 1Khz ) 3. Standard Capacitors ( 2 Nos ) ( In Pf And Nf Range ) 4. Gold Plated Parallel Plate Dielectric Cell-I ( 75Mm ) 5. Gold Plated Parallel Plate Dielectric Cell-Ii ( 25 Mm ) 6. Dielectric Sample For Dielectric Cell-I ( Glass – 2 Nos, Bakellite-1 No, Pcb -1 No ) 7. Dielectric Sample For Dielectric Cell-Ii ( Pzt-2 Nos, Barium Titanate -1 No 25 Mm Diameter With 8. Instruction Manual Complete Unit Should Be Housed In Metal Cabinet Of 416X230x165mm With Effective Electromagnetic Shielding With Proper Connecting Cables. ) 19 Forced Oscillator And Resonance Set Up ( It Should Consists Of Base Unit With Frequency Generator ( Mass Attached To Spring Which Is Connected To A Cord Passing Over A Pully And Further Connected To Drive Wheel ) , Spring Of Known Spring Constant, Scale Attached To Setup, Weight 50G Four Each. ) Refrective Index Setup ( The Set-Up Should Consist Of Spectrometer, Diffraction Grating, Mercury Light Source, Prism, Reading Lens Etc. Spectrometer Standard: 7 Diacircle Reading 30 Seconds. The Used In Telescope And Collimator Has To Be Achromatic And Provided With Rack And Pinion Focusing Arrangement Telescope Arm And Prism Table Are To Be Provided With Fine And Coarse Adjustment. The Prism Table Is Provided With Three 20 Leveling Screws And Is Engraved With Concentric Rings & Lines. The Scales And Verniers Are Of Stainless Steel ) 21 He-Ne Laser Source And Diffraction Grating Setup ( He-Ne Laser Source · Output Power: 0.5 Mw – 5 Mw · Wavelength: 632.8Nm · Polarized Or Randomly Polarized Output · Tem00 Mode · Beam Divergence: <1.0 Mrad · Beam Diameter: ≤ 0.7Mm 2. Power Supply ( Input 240 V / 50 Hz ) 3. Optical Bench ( 1.5 Meter ) 4. Reflection Grating ( 15000 Lines Per Inch ) 5. Transmission Grating ( 15000 Lines Per Inch ) 6. Photo Detector With Bnc Connector And Holder 7. Screen ( 12 X 12 ) With Clamp Type Holder 8. Knife Edge With Micrometer Movement 9. Digital Multimeters 10. Scale With Mount ) 22 Optical Fiber Setup ( The Setup Consists Of Laser Diode ( 5Mw, 632Mm ) , Objective ( 10X ) , Fiber ( 1Mtr Long ) , Dectector With Bnc Connector Autoarranging Multimeter, Chucks And Bases ( 2Nos ) To Hold The Components, Screen With Circular Graduations, One Circular Base With Linear And Circular Motion And Optical Bench. ) 23 Friction Table And Horizental Board ( One Big Table With Clamp And Horizental Board ) 24 Searles Apparatus With Weight Box. ( For Different Weight Measure ) 25 Terminal Velocity Measure Stocks Law Set Up ( Glycerin Stop Watch Bob, Tube Clamp Stand 26 Pullingers Apparatus ( Heet Burner Tripod Stand, Weeker Tube Iron Rode Etc. ) 27 Fortins Barometer 28 Mercury Thermameter ( Mercury Thermameter 0 To 360 C, 300Mm Long ) 29 Ultrasonic Interfero Meter ( Measuring Device For Velocity Of Ultra Sonic ) 30 Plane Mirror Interface 31 Glass Slab ( 75 X 50 X 18 Mm And Glass Prism ( 50 X 50 ) ) 32 Convex Lens ( 2 Convex X 50Mm ) 33 Ohms Law Apparatus ( P=1.5Wp Volt-220V I-250 Ma ) 34 Post Office Box ( Different Resistence Measure ) 35 Kirchoffs Law Verification Kit ( Electrical Curcit ) 36 Capaciter And Kits 37 Galvanometer ( Curcit ( Dc ) 30-30V ) 38 Ammeter 39 Volt Meter 40 Optical Projection System ( Ohp / Lcd For Project Report )