Tender For Special Repair To Omqs / Smqs At Af Station Bihta--- 1 Excavation in trenches in soft/loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 M deep and getting out including forming bottom surface for laying of pipes complete all as specified and directed. 2 Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 mm thick complete all as specified and directed. 3 Removal of excavated material to a distance not exc 50 Meter and depositing wheredirected at a level not exceeding 1.5 M above the starting point complete all as specified and directed. 4 Supplying, laying and cushioning for cable protection in trenches 8 cm deep before laying cable and 15 cm deep over the cable including well punning complete all as specified and dierected 5 M&L cement concrete 1:5:10 type E2, using 40 mm graded stone coarse aggregate in sunken floor, all as specified and directed 6 M&Lreinforced Cement concrete (1:2:4) type B-1, (20 mm graded aggregate) as in slab supported on walls, beam, column and in similar work, complete all as specified and directed. 7 S & F for factory made solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet, reinforced with MS square tube fixed in opening complete as per manufacturers specifications and as directed. 8 S & F for 30 mm thick factory made solid panel PVC door shutter conferming to criteria of testing as per IS : 4020, consisting of frame made out of MS tube of 19 guage thickness & size 19x19mm for stiles and 15x15mm for top & bottom rails MS frames shall have a coat of red oxide primer of approved make and shall be covered with 5mm thick heat moulded PVC `C channel of size 30x50mm forming styles and 5mm thick 75mm wide PVC sheets for top rail lock rail and bottom rail on either side and 10mm (5mmx2) thick 20mm wide cross PVC sheet as gap insert for top rail and bottom rail panelling of 5 mm thick PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rail with 30 mm wide x 5 mm thick PVC sheet beading on either side and joined together with solvent cement, adhesive and an additional 5 mm thick PVC strip of 20 mm width is to be struck on the interior side of C channel using PVC solvent adhesive complete as per manufacturers specifications & drawings & all as directed. 9 S & F pressed steel frames of size 125 x 60 mm for doors with one or more rebates including necessary fixing lugs hinges lock strike plate etc complete as specified. 10 S & F pressed steel frames of size 105 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete as specified. 11 M & L for PCC 1:3:6 type C-0 using 12.5mm aggregate crushed stone aggregate as in filling back side of pressed steel door/window frames, all as specified & directed. 12 S&F glazed/wire gauged/skeleton shutter 35 mm thick out of (well kilnseasoned)2nd class hard wood (hollock) the size of rails and style as per IS chemically pressure treated in factory gainst termite infestation prepared to receive wire gauge (without sash bars) edges of frame chamfered or rounded fitted with cut and mitered beads, all as specified & directed.(Note : Wire gauge/glazing to be measured and paid separately). 13 S&F factory made 40 mm thick plain, framed, panelled shutter (two panel) with lock rail using 2nd class HW (Hollock) kiln seasoned andchemicallypressure treated the size of rail and style as per IS 1003 (Part-I) and panel insert of 9mm thick BWP commercial facing plywood or 12mm veneered particle boards with commercial ply all as specified 14 S&F Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed in 2nd class hardwood. 15 S&F of 25 mm thick flush shutters, solid core construction, with block board core and ply wood face panels, commercial type on both sides all as specified and as directed. 16 S&F in repairs of 12 mm thick plywood, grade BWR, type BB, fixed with screws to timber frame work etc. in built in cupboard complete all as specified and as directed. 17 S&F for 100mm long mild steel butt hinges, heavy weight cold rolled mild steel, all as specified and as directed. 18 S&F for 75mm long mild steel butt hinges, heavy weight cold rolled mild steel, all as specified and as directed. 19 S&F 150 mm long aluminium anodised handles, cast type, all as specified and as directed. 20 S&F for 150 mm long Aluminium, anodised, barrel tower bolts of extruded section, all as specified and as directed. 21 S&F 300 mm long aluminium alloy, anodised, sliding dooor bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy, all as specified and as directed. 22 S&F for 200 mm long Aluminium, anodised, barrel tower bolts of extruded section, all as specified and as directed. 23 S&F mild steel 300 mm ordinary rat tail rod pattern springs including roller & rooler plate complete all as specified and as directed. 24 S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor overall length of cover plate 140mm, all as specified and as directed. 25 S&F hasp and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws of 100 mm size, all as specified and as directed. 26 S&F in repairs of harrison rail mild steel chromium plated of 19/20mm dia for curtain rod fixed with two Nos of brackets for each rail all as specified and as directed. 27 S&F mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm, all as specified and as directed. 28 S&F anodised aluminium powder coated frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified & directed. (Note : Minimum thickness of powder coating 50 micron). 29 S&F anodised aluminium powder coated window and ventilator shutters, hung type without sash bar, aluminium section weighing not less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. anodised aluminium fittings such as peg stays 150 mm long (01 No), hinges B-21 100 mm long (02 No), suitable handle (01 No) complete all as specified.(Note : Minimum thickness of powder coating 50 micron). 30 S&F sheet glass 4 mm thick ordinary quality & glazing with rubber gasket in square n.exc 0.5 Sqm in each pane, all as specified and directed.. 31 S&F 3 mm thick figured glass, pinhead type in squares n.exc 0.50 sqm each pane, all as specified and directed. 32 M&Lfor mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete, all specified and directed. 33 S&F in repair 18mm thick celuka PVC sheet minimum 600 Kg/Cum density grade 1 quality of both side plain white colour rigidlam glossy finish fixed with screws, solvent cement/adhesive as per manufacturer instructions to make kitchen cabinet sides top and bottom and shelves inside the cabinet completeas per specifications and as directed. Note:- (i) Cup board accessories ie fittings,handles,hinges, will be measured and paid under this schedule.(ii) Quoted rates deem to be include fixing of cabinet on wall with appropriate rawl plug/ dash through fastener (hammer type).(iii) Fabrication and installation of cabinet to be carried out by authorised vendor of manufacturer only. 34 S&F auto closing stainless steel (Grade 304) hinges 35 mm of 0 crank (KH-001) or 8 crank (KH-002) openable at 110 degree for kitchen cabinet shutters all as specified & directed. 35 S&F stainless steel handles of 100 mm size for kitchen cabinet shutter complete all as specified. 36 M&L for APP basedpolymeric water proofing membrane minimum weight 3 Kg/ Sqm and minimum 3mm thick reinforced with polyster non wove fabrick (Weight not less than 150gms/Sqm), laid with torched application with the strict supervision of manufacturers technical supervisor, laid over hot blown bitumen 85/25 grade @1.2 kg per Sqm over bitumen primer @0.30 Ltr/sqm including cleaning surface, complete all as specified and directed.(Note - Membrane shall be laid with 100mm side/end lap on prepared surface as per manufacturer instruction work shall be carried out strictly with the technical tradesmen and supervision of technical staff of manufacturer) 37 M&L for 40 mm thick brick tiles laid on bedding of 15 mm thick cement mortar (1:6) and joints grouted flush in cement mortar (1:3) on treated roof all as specified and as directed 38 M&L for applying bituminous primer @ 0.40 Kg/Sqm and applying one coat of hot blown bitumen of grade 85/25 @ 1.20 kg/Sqm as in sunken complete all as specified including fixing of 40 mm dia GI spout pipe at bottom of slab/plastered surface etc, all as specified & directed. 39 Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc, all as specified & directed. 40 M&L for providing cement concrete type B-1, 1:2:4 (20 mm graded aggregate) as in roof padding, roof kerbs (rounded or chamfered on edge) etc all as specified & directed. 41 M&L 75 mm thick cement concrete type D-2, 1:4:8 (using 40 mm graded aggregate) as in subbase to floor, ll as specified and directed.. 42 M&L for 25 mm thick cement concrete type B-0, 1:2:4 (12.5 mm graded aggregate) as on floor, ll as specified and directed.. 43 M & LNon-skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tiles including 15 mm thick screed bed in cement mortar 1:6 all as specified and directed. 44 M & LNon-skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tiles including 15 mm thick screed bed 1:6 all as specified and directed. 45 M & L glazed ceramic coloured tiles of approved quality ISI marked (450 x 300 x 7 mm / 350 x 250 x 7 mmthick) as in vertical surfaces such as skirting dados etc set jointed in neat cement slurry and pointed in coloured cement to match with the tiles including 1:4 cement plaster 10 mm thick on brick work and concrete surface, all as specified and directed. 46 M&L for 15 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms (including a hole of gas pipe) and like including 15 mm thick screed bed in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, all as specified and directed. 47 Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and similar situations, all as specified and directed.. 48 M&L for rendering 10 mm thick in cement mortor 1:4 on fair faces of brick work, surfaces finished even and fair without using extra cementwith water proofing compound, all as specified and directed. (NOTE :- WPC shall be measured and paid seperatelly). 49 M&L for 10 mm thick rendering in cement mortor (1:6) on air faces of brick work, surfaces finished even and smooth without using extra cement cement, all as specified and directed 50 M & L for 15 mm thick rendering in CM (1:4) on vertical surfaces of brick walls finished even and smooth without using extra cement with using water proofing compound, all as specified & directed. (Note - WPC will be measured and paid separately). 51 M&L for 5 mm thick rendering in CM (1:3) on ceiling surfacesoffinished even and fair without using extra cement, all as specified & directed.. 52 Supply only integral water proofing compound 53 S&F 15 mm GI tubes medium grade with all fitting and fixed complete to walls, ceilings or laid infloors including taking up or down old steel tube complete all as specified and directed. 54 S&F 20 mm GI tubes medium grade with all fitting and fixed complete to walls, ceilings or laid infloors including taking up or down old steel tube complete all as specified and directed. 55 M&L for preparation of new wood basesurfaces of any description, over 10 cm in width or girth, not otherwise described and appling twocoats of synthetic enamel paint (ordinary tint) overone coats of pink primer, all as specified and directed. 56 M&L Peparation of old painted wooden surfaes of any dscription over 10cm width or girth and applying one coatof synthetic enamel paint complete all as specified and as directed. 57 M&L Peparation of old painted steel surfaces of any description over 10cmwidth or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. 58 M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash all as specified and directed. 59 M&L for preparation of old surfaces of ceiling and applying two coats of white washall as specified and directed. 60 M&L for preparation of new plastered surfaces of wall and applying three coats of white wash all as specified and directed. 61 M&L for preparation of old decorated plasteredsurfaces of wall and applying two coat of white wash all as specified and directed. 62 M&L for preparation of new plastered surfaces of wall and applying two coats oil bound distemper over a coat of alkali resistant primer over a coat of 1 mm thick wall care putty in two different layers complete all as specified & as directed.(Note - Treatment slall be carried our by spraying with mechanical means) 63 M&L for complete removal of existing treatment of wall and applying two coats oil bound distemper over a coat of alkali resistant primer over a coat of 1 mm thick wall care putty in two different layers complete all as specified & as directed.(Note - Treatment slall be carried our by spraying with mechanical means) 64 M&L for complete removing of existing treatment of wall surfaces by scrapping with mechanical sander (having mechanical vacuum mechanism)to make surface clean, free from dust, loose paint etc and applying two coat of cement base paint of different colours complete all as specified and directed. 65 M&L for preparation of new plastered surfaces of walls and applying two coat of cement base paint of any colours and pattern (two or more colours) complete all as specified and directed.(Note :- Colour and pattern of paint will be directed by GE) 66 M&L for PVC (SWR) pipe of 110 mm boresingle socketed in any length with rubber ring joint fixed to wall with suitable clamps of adequate numbers etc complete all as specified and directed. 67 S&FPVC SWR bends 110 mm boreall as specified and directed. 68 S&F Cast iron soil, waste pipe100 mm dia, sand cast, in any length with or without ear, with cement joint, laid in trenches, complete all as specified. 69 S&F Cast iron soil, wastepipe100 mm dia, sand cast, in any length with or without ear, with cement joint, laid in trenches, complete all as specified. 70 S&F Cast iron soil, waste and vent pipe100 mm dia, sand cast, in any length with or without ear, with cement joint, fixed on wall, complete all as specified. 71 S&F Cast iron soil, waste and vent pipe100 mm dia, sand cast, in any length with or without ear, with cement joint, fixed on wall, complete all as specified & directed. 72 S & F in repairs of 100 mm bore cast iron bends of any radius diminshing pieces or tappers (larger bore measured), all as specified & directed.. 73 S & F in repairs of 75 mm bore cast iron bends of any radius diminshing pieces or tappers (larger bore measured), all as specified & directed.. 74 S&F Cast iron cowls of 100 mm bore pipe, all as specified & directed. 75 S & F in repairs cast iron floor trap with chromium plated graating of 100 mm size including jointing to waste pipe with cement joints etc, all as specified & directed. 76 S&F Soap dish brass chromium plated decorative type, size 160X90mm complete all as specifed and directed. 77 S&F 600 mm X 450 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC buildg board or commercial plywood and fixed to wooden plugs with CPbrass screws and cup washers complete all as specified and directed. 78 S&F in repairBrass chromium plated, tubular towel rails 20 mm dia, D- type, 60cm long between flanges, completed all as specified and directed. 79 S&F in repair chromium plated 125 mm size shower rose with swivel joints, in square with CP long shank arm including fixing to steel pipe or union of 15 mm bore, complete all as specified and as directed. 80 S&F in repairs vitreous china squatting pan “Orissa Pattern” of size 580 x 440mm white with integral foot rest (excluding flushing cistern & flush pipe) including connection to trap and to flush pipes etc and lime concrete bedding complete all as specified in SSR and including S&F trap set complete all as specified and directed. 81 S&F in repairs PVC flushing cistern 10 ltr capacity valve less syphonic action type low level with and including dual flushball valve float & handle, waste pipe & brackets complete set complete all as specified and directed. 82 S & F in repairVitreous China wash basin, flat back, size 630X450mm white, excluding waste coupling, chain & plug, CI prackets, PVC waste pipe 32 mm,and porcelain stopper but including brackets. 83 S&F in repair chromium plated fancy type, stop cock/angular cock, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends of size 15mm bore. complete all as specified and directed. 84 S&F in repair chromium plated concealed type, stop valve, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends of size 15mm bore. complete all as specified and directed. 85 S & F in repair 15mm bore chromium plated bib tap, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron or brass ferrule, complete all as specified and directed. 86 S&F Sheet glass assembly consisting of 5.5mm thick sheet glass shelf 12mm wide with chromium plated bracket guard and railing, 600mm long,complete all as specified and directed. 87 S & F in repair Pillar taps fancy type(long body)cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, screwed for iron pipe, complete all as specified and directed. 88 S&F in repairPVC connections 15mm size with PTMT nuts of length 450 mm, complete all as specified and as directed. 89 S&Frotational moulded polythene water storage tank of capacity 500 ltrs (Cylindrical/vertical with closed top), triple layer construction, ISI marked, hoisted & fixed in position including followings :-(i)20 mm GI pipe medium grade,over flow 450mm long.(ii) 20 mm GI pipe medium grade waste pipe 600mm long.(iii) 20 mm brass ball valve/Float valves, high pressure & high density plastic ball screwed for iron pipe and fixed.(iv) 20 mm Gun metal globe/Gate valve with iron wheel head, screwed on both ends for fixing including one GI nipple(20mm bore). 90 S&F in repair sink with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and waste; including pvcwaste pipe, CP waste coupling,bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified anddirected. 91 S&F 1mm thick stainless steel kitchen plate rack of size 750x 900mm best quality assembled with brass washer and nut and bolts including hooks (spoon/cup holders) complete all as specified & directed. 92 Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level), all as specified & directed..Note : - All demolished items/ debris to be removed out side of MoD land. 93 Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for, all as specified & directed..Note : - All demolished items/ debris to be removed out side of MoD land. 94 Demolition of reinforced cement concrete of any description & in any position, complete all as specified and directed. 95 Dismantling of stone slabs and tiles of any description or thickness in floors aprons etc including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. 96 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises,all as specified and directed. 97 Taking down cement plaster on brick or stone walls, etc, incl raking out joints, hacking for key, scrubbing down with water, etc & prepare to receive new plaster complete all as specified and directed 98 Taking down chowkats or frame with shutter (without taking out shutter from the frame) not exceeding 1.50 sqm each and removal from site all as specified and directed. 99 Taking down chowkats or frame with shutter (without taking out shutter from the frame) exceeding 1.50 sqm and n exc 4.00 sqm each and removal from site all as specified and directed 100 Taking down of shutters of any description exc 1.00 Sqm but n. exc 2 Sqm each, all as specified and directed 101 Taiking up or down steel tubing and connections, 15 mm bore including cleaning, complete all as specified and directed. 102 Taiking up or down steel tubing and connections, 20 mm bore including cleaning, complete all as specified and directed. 103 Dismantling PVC water tankcapacity exceeding 250 but not exceeding 500 ltr, complete all as specified and directed. 104 Taking down100/75 mm cast iron soil waste pipe (any size or patterns) moulding all fittings heads shoes, bends etc (measured over all as fixed along the confrece line over fittings and accessories), all as specified and directed. 105 Taking down rain water pipes (any size or pattern) ,including all fittings all as specified and directted . 106 Demolition of bricks (laid flat or on edge) or brick tiles in floors, channels, kerbs, aprons, etc (each layer) laid, bedded and pointed in any mortar including removal of debris/muds etc complete all as specified and as directed.Note : - All demolished items/ debris to be removed out side of MoD land. 107 Demolition of mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) and finally cleaning the surface with wire brush to remove old treatment to lay PCC padding, complete all as specified and directed..Note : - All demolished items/ debris to be removed out side of MoD land 108 Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc, complete all as specified and directed. 109 Taking down old unserviceable MCB DB TPN4 way (Vertical), double door, 415 V, AC, 50 Hz, includingMCB63 Amps 16 KA ,IP-40 protection conforming to IS-13032 universal mounting with copper bus bar,neutral link, earth link, earthing studs, detachable gland plates with knockouts on both sides, complete all as specified & directed. 110 Material and labour for concealed point wring for One light/fan/exhaust fan point controlled by 1 No,one way 5/6 Amp switch ,using approved colour coding (Phase-red,Neutral-black,Earth-green) complete with FRLS PVC insulated and unshealthedstranded copper conductor cable 1.5 sqmm single coreconforming to IS 694 including medium duty concealed unplasticised PVC conduit conforming to IS 9537(part-3) and ISI marked not less than 20 mm dia with concealed in wall pressed steel terminal box of not less than 2 mm thick of required size including painting terminal boxs inside and outside with two coat of synthetic enamle paint over one coat of red oxide primerwith top cover3 mm thickbakelight laminated sheetwith brass screws and Cup washer with all assessories including FRLS PVC insulated and unshealthedstranded copper conductor cable 1.5 sqmm single core in green colouras earth wireconnected to earth dolly . complete all as specified and directed . 111 All as per Item No 110 above butfor One 3 pin /5 pin socket outlet 5 Amp controlled by 1 No one way 5/6 Amp switch on same board along with other switches ,fan regulator etc. 112 All as per Item No 110 above butfor One 3 pin /5 pin socket outlet 5 Amp controlled by 1 No one way 5/6 Amp switch on independent board. 113 All as per Item No 110 above butfor One call bell/buzzer point controlled by one push button switch. 114 Material and labour for point wring ,using approved colour coding (Phase-red,Neutral-black,Earth-green) complete for one socket outlet 15 Amp on independent board with FRLS PVC insulated and unshealthedstranded copper conductor cable 2.5 sqmm single coreconforming to IS 694 including medium duty concealed unplasticised PVC conduit conforming to IS 9537(part-3) and ISI marked not less than 20 mm dia with concealed in wall pressed steel terminal box of not less than 2 mm thick of required size including painting terminal boxs inside and outside with two coat of synthetic enamle paint over one coat of red oxide primerwith top cover3 mm thickbakelight laminated sheetwith brass screws and Cup washer with all assessories including FRLS PVC insulated and unshealthedstranded copper conductor cable 2.5 sqmm single core in green colouras earth wireconnected to earth dolly complete all as specified and directed. 115 S&F switch piano flush button single pole one way 5/6 Amp, 240 Volts conforming to IS 3854 ISI marked all as specified and directed. 116 S&Ffor socket outlet, 5 Pin, 5/6 Amp flush type conforming to IS 1293 ISI marked all as specified and directed. 117 S&F switch piano flush button single pole one way 15 Amp, 240 Volts conforming to IS 3854 ISI marked including taking down old one, all as specified and directed. 118 S&Ffor socket outlet, 3 Pin, 15 Amp flush type conforming to IS 1293 ISI marked including taking down old one, all as specified and directed. 119 S&Fceiling rose, surface Bakelite,isolated bodythree terminals including taking down old one, all as specified and directed. 120 S&F Lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings, all as specified and directed. 121 Supply only LED Bulb of 09 Watt complete all as specified and directed. 122 S&F forbell push flush type 5 A SP 240 V all as specified and directed. 123 S&FBell (Ding-Dong) 230 volts, single pole all as specified and directed. 124 Taking down ceiling fan including cable, dismantling blades and carry out mnr repair and fixing of damaged parts like capacitor, bushes, bearings and screws etc and keeping in safe custody of contractor up to re fixing in the same. all as specified & directed. 125 M&L for Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust, all as specified and directed. 126 Hanging only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan, all as specified and directed. 127 M & L for repair / rewinding of ceiling fand replacement of requisite spares like bush, bearing, down rod, capacitor, fan clamp, fan blade etc if necessary all as specified and directed. 128 M & L for repair / rewinding of exaust fand replacement of requisite spares like bush, bearing, capacitor, fan clamp, fan blade etc if necessary all as specified and directed. 129 Supply and fixing LED tube lights fitting 1x 18W, 220V, including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling roseand complete all as specified and directed. 130 Supply and fixing LED batten type tube light complete fitting 1x 10 W, 220V,connecting up with three core flexible copper conductor cable of suitable size from ceiling roseand complete all as specified and directed. 131 Supply &Fixing and connecting up complete MCB DB TPN 4 way (Vertical), double door, 415 V, AC, 50 Hz, with and includingMCB63 Amps 16 KA ,IP-40 protection conforming to IS-13032 universal mounting with copper bus bar,neutral link, earth link, earthing studs, detachable gland plates with knockouts on both sides, complete all as specified & directed. 132 S&F sheet metal enclosures (MCB Distribution board) when MCB’s to be used singlepole and neutral 8 ways 220 volt with 200 amps rated bus bar, double door with bus bar neutral link earth bar, Din rail, necessary blanking plated, including fixing DB flush in wall complete with making good disturbed surfaces and colour matching all as specified and directed including taking down old one, complete all as specified & directed. 133 S&F MCB’s single pole, 10 KA ,32 Amp to 40 Amp 240 Volts,and of B series with required wiring connections and lugs etc and erecting in provided enclouser/destribution board.MCBs shall be of current limiting type ,ISI marked conforming to IS 8828-1996, including taking down old one, complete all as specified & directed. 134 S&F Sheet metalenclosure with socket plug top and MCBs single pole with a two pin and earth plug andsocket complete with one single pole MCB ofC series of cap 20 Amps including taking out the old one all as specified and directed. 135 S&F MCB’s DP, 10 KA, 32 Amp to 40 Amp 240 Volts,and of B series with required wiring connections and lugs etc and erecting in provided enclouser/destribution board. MCBs shall be of current limiting type ,ISI marked conforming to IS 8828-1996,including taking down old one complete all as directed. 136 Supply and fixing STUD 10 W LED lights energy saving Bulk Head Luminaries including LED light driver, holder connecting up with three core flexible copper conductor cable of suitable size from ceiling roseand complete all as specified and directed. 137 S&F Sub main wiring using approved colour coding (Phase-red,Neutral-black,Earth-green) complete with two single core FRLS PVC insulated and unsheathedstranded copper conductor cable 6 sqmmas current carrying conductor and one run of 6.0 sqmm as neutral cable ,voltage rating 1100 volt ,ISI marked drawn in and including concealed PVC conduit ISI marked of dia not less than 25 mm and thickness 2 mm with stranded accessories along with one run of FRLS PVC green colour insulated,unshealthed,stranded copper conductor of size 6 sqmm all as specified and directedincluding taking down old one, complete all as specified and directed.(Note: Two run of single core FRLS PVC cable with one run of earth contunity conductor and conduit shall be measured as one unit.) 138 M&L for earthing complete with galvanized steel earth plate 600x600x6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead wire of 4mm dia as earthing lead by means of bolts, nuts, check-nuts, and washers of galvanised iron or steel besides welding at all joints as shown in drawings and including excavation and earth work, GI pipe light grade 15 mm bore for protection of GIwire from earth electrodeto test point /machinery / equipment.supplying and laying charcoal dustcomman saltPCC(1:2:4) type B1 using 20 mm gradedstone agregratechamber andRCC cover 54 cm X 54cm x50 mm thick (1:2:4) type B-1using 20 mm stone agrigrtae )reinforced with 8 mm dia TMT bars @75mm C/C both ways with mild steel handle 12 mm dia,using round bar ,PGI funnel with wire mesh, 20 mm dia GI pipe medium grade for watering all as shown in electrical plate No-3 of SSR part-1including testing and taking out the old one complete all as specified and directed(Note - Cost of GI wire and GI protection pipe up to a distance 7.5 M shall be includedin quated rate of above Items) 139 S&F 415 V, 10 KA ,B curve miniature circuit breaker MCB TPN 63 Amps, 16 KA complete all as specified and directed. 140 Supply, Laying, connecting and testing XLPE cable underground PVC insulated and over all sheathed with aluminium conductor heavy duty 1100 volts grade 3.5 core 35 sqmm sizes, laid in trenches, floors, ducts passing through pipe forroad crossing etc including taking down old UNSV cable of any size complete all as directed including taking out old damaged cable and all as specified and directed. (NOTE -excavation, earth work, brick protection sand cushioningand GI pipe etc shall be measured & paid for separately) 141 M&L for laying of bricks subclass ‘B’ old size having crushing strengh not s than 75 Kg/Sqcm, laid flat perpendicular to the direction of cable for protection of cable complete all as specified & directed. 142 M&L GI tubing 50 mm dia light grade, laid in trench/floor or fixed on wall with all fixingaccessories etc as specified and directed.

Tender Notice

37044332

Military Engineer Services

Indian


bihta

Bihar

May 08, 2023

Key Value

69 Lakhs

69 Lakhs

69 Lakhs

To Download Tender Document Click on the below link

Tender For Special Repair To Omqs / Smqs At Af Station Bihta--- 1 Excavation in trenches in soft/loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 M deep and getting out including forming bottom surface for laying of pipes complete all as specified and directed. 2 Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 mm thick complete all as specified and directed. 3 Removal of excavated material to a distance not exc 50 Meter and depositing wheredirected at a level not exceeding 1.5 M above the starting point complete all as specified and directed. 4 Supplying, laying and cushioning for cable protection in trenches 8 cm deep before laying cable and 15 cm deep over the cable including well punning complete all as specified and dierected 5 M&L cement concrete 1:5:10 type E2, using 40 mm graded stone coarse aggregate in sunken floor, all as specified and directed 6 M&Lreinforced Cement concrete (1:2:4) type B-1, (20 mm graded aggregate) as in slab supported on walls, beam, column and in similar work, complete all as specified and directed. 7 S & F for factory made solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet, reinforced with MS square tube fixed in opening complete as per manufacturers specifications and as directed. 8 S & F for 30 mm thick factory made solid panel PVC door shutter conferming to criteria of testing as per IS : 4020, consisting of frame made out of MS tube of 19 guage thickness & size 19x19mm for stiles and 15x15mm for top & bottom rails MS frames shall have a coat of red oxide primer of approved make and shall be covered with 5mm thick heat moulded PVC `C channel of size 30x50mm forming styles and 5mm thick 75mm wide PVC sheets for top rail lock rail and bottom rail on either side and 10mm (5mmx2) thick 20mm wide cross PVC sheet as gap insert for top rail and bottom rail panelling of 5 mm thick PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rail with 30 mm wide x 5 mm thick PVC sheet beading on either side and joined together with solvent cement, adhesive and an additional 5 mm thick PVC strip of 20 mm width is to be struck on the interior side of C channel using PVC solvent adhesive complete as per manufacturers specifications & drawings & all as directed. 9 S & F pressed steel frames of size 125 x 60 mm for doors with one or more rebates including necessary fixing lugs hinges lock strike plate etc complete as specified. 10 S & F pressed steel frames of size 105 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete as specified. 11 M & L for PCC 1:3:6 type C-0 using 12.5mm aggregate crushed stone aggregate as in filling back side of pressed steel door/window frames, all as specified & directed. 12 S&F glazed/wire gauged/skeleton shutter 35 mm thick out of (well kilnseasoned)2nd class hard wood (hollock) the size of rails and style as per IS chemically pressure treated in factory gainst termite infestation prepared to receive wire gauge (without sash bars) edges of frame chamfered or rounded fitted with cut and mitered beads, all as specified & directed.(Note : Wire gauge/glazing to be measured and paid separately). 13 S&F factory made 40 mm thick plain, framed, panelled shutter (two panel) with lock rail using 2nd class HW (Hollock) kiln seasoned andchemicallypressure treated the size of rail and style as per IS 1003 (Part-I) and panel insert of 9mm thick BWP commercial facing plywood or 12mm veneered particle boards with commercial ply all as specified 14 S&F Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed in 2nd class hardwood. 15 S&F of 25 mm thick flush shutters, solid core construction, with block board core and ply wood face panels, commercial type on both sides all as specified and as directed. 16 S&F in repairs of 12 mm thick plywood, grade BWR, type BB, fixed with screws to timber frame work etc. in built in cupboard complete all as specified and as directed. 17 S&F for 100mm long mild steel butt hinges, heavy weight cold rolled mild steel, all as specified and as directed. 18 S&F for 75mm long mild steel butt hinges, heavy weight cold rolled mild steel, all as specified and as directed. 19 S&F 150 mm long aluminium anodised handles, cast type, all as specified and as directed. 20 S&F for 150 mm long Aluminium, anodised, barrel tower bolts of extruded section, all as specified and as directed. 21 S&F 300 mm long aluminium alloy, anodised, sliding dooor bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy, all as specified and as directed. 22 S&F for 200 mm long Aluminium, anodised, barrel tower bolts of extruded section, all as specified and as directed. 23 S&F mild steel 300 mm ordinary rat tail rod pattern springs including roller & rooler plate complete all as specified and as directed. 24 S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor overall length of cover plate 140mm, all as specified and as directed. 25 S&F hasp and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws of 100 mm size, all as specified and as directed. 26 S&F in repairs of harrison rail mild steel chromium plated of 19/20mm dia for curtain rod fixed with two Nos of brackets for each rail all as specified and as directed. 27 S&F mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm, all as specified and as directed. 28 S&F anodised aluminium powder coated frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified & directed. (Note : Minimum thickness of powder coating 50 micron). 29 S&F anodised aluminium powder coated window and ventilator shutters, hung type without sash bar, aluminium section weighing not less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. anodised aluminium fittings such as peg stays 150 mm long (01 No), hinges B-21 100 mm long (02 No), suitable handle (01 No) complete all as specified.(Note : Minimum thickness of powder coating 50 micron). 30 S&F sheet glass 4 mm thick ordinary quality & glazing with rubber gasket in square n.exc 0.5 Sqm in each pane, all as specified and directed.. 31 S&F 3 mm thick figured glass, pinhead type in squares n.exc 0.50 sqm each pane, all as specified and directed. 32 M&Lfor mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete, all specified and directed. 33 S&F in repair 18mm thick celuka PVC sheet minimum 600 Kg/Cum density grade 1 quality of both side plain white colour rigidlam glossy finish fixed with screws, solvent cement/adhesive as per manufacturer instructions to make kitchen cabinet sides top and bottom and shelves inside the cabinet completeas per specifications and as directed. Note:- (i) Cup board accessories ie fittings,handles,hinges, will be measured and paid under this schedule.(ii) Quoted rates deem to be include fixing of cabinet on wall with appropriate rawl plug/ dash through fastener (hammer type).(iii) Fabrication and installation of cabinet to be carried out by authorised vendor of manufacturer only. 34 S&F auto closing stainless steel (Grade 304) hinges 35 mm of 0 crank (KH-001) or 8 crank (KH-002) openable at 110 degree for kitchen cabinet shutters all as specified & directed. 35 S&F stainless steel handles of 100 mm size for kitchen cabinet shutter complete all as specified. 36 M&L for APP basedpolymeric water proofing membrane minimum weight 3 Kg/ Sqm and minimum 3mm thick reinforced with polyster non wove fabrick (Weight not less than 150gms/Sqm), laid with torched application with the strict supervision of manufacturers technical supervisor, laid over hot blown bitumen 85/25 grade @1.2 kg per Sqm over bitumen primer @0.30 Ltr/sqm including cleaning surface, complete all as specified and directed.(Note - Membrane shall be laid with 100mm side/end lap on prepared surface as per manufacturer instruction work shall be carried out strictly with the technical tradesmen and supervision of technical staff of manufacturer) 37 M&L for 40 mm thick brick tiles laid on bedding of 15 mm thick cement mortar (1:6) and joints grouted flush in cement mortar (1:3) on treated roof all as specified and as directed 38 M&L for applying bituminous primer @ 0.40 Kg/Sqm and applying one coat of hot blown bitumen of grade 85/25 @ 1.20 kg/Sqm as in sunken complete all as specified including fixing of 40 mm dia GI spout pipe at bottom of slab/plastered surface etc, all as specified & directed. 39 Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc, all as specified & directed. 40 M&L for providing cement concrete type B-1, 1:2:4 (20 mm graded aggregate) as in roof padding, roof kerbs (rounded or chamfered on edge) etc all as specified & directed. 41 M&L 75 mm thick cement concrete type D-2, 1:4:8 (using 40 mm graded aggregate) as in subbase to floor, ll as specified and directed.. 42 M&L for 25 mm thick cement concrete type B-0, 1:2:4 (12.5 mm graded aggregate) as on floor, ll as specified and directed.. 43 M & LNon-skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tiles including 15 mm thick screed bed in cement mortar 1:6 all as specified and directed. 44 M & LNon-skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tiles including 15 mm thick screed bed 1:6 all as specified and directed. 45 M & L glazed ceramic coloured tiles of approved quality ISI marked (450 x 300 x 7 mm / 350 x 250 x 7 mmthick) as in vertical surfaces such as skirting dados etc set jointed in neat cement slurry and pointed in coloured cement to match with the tiles including 1:4 cement plaster 10 mm thick on brick work and concrete surface, all as specified and directed. 46 M&L for 15 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms (including a hole of gas pipe) and like including 15 mm thick screed bed in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, all as specified and directed. 47 Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and similar situations, all as specified and directed.. 48 M&L for rendering 10 mm thick in cement mortor 1:4 on fair faces of brick work, surfaces finished even and fair without using extra cementwith water proofing compound, all as specified and directed. (NOTE :- WPC shall be measured and paid seperatelly). 49 M&L for 10 mm thick rendering in cement mortor (1:6) on air faces of brick work, surfaces finished even and smooth without using extra cement cement, all as specified and directed 50 M & L for 15 mm thick rendering in CM (1:4) on vertical surfaces of brick walls finished even and smooth without using extra cement with using water proofing compound, all as specified & directed. (Note - WPC will be measured and paid separately). 51 M&L for 5 mm thick rendering in CM (1:3) on ceiling surfacesoffinished even and fair without using extra cement, all as specified & directed.. 52 Supply only integral water proofing compound 53 S&F 15 mm GI tubes medium grade with all fitting and fixed complete to walls, ceilings or laid infloors including taking up or down old steel tube complete all as specified and directed. 54 S&F 20 mm GI tubes medium grade with all fitting and fixed complete to walls, ceilings or laid infloors including taking up or down old steel tube complete all as specified and directed. 55 M&L for preparation of new wood basesurfaces of any description, over 10 cm in width or girth, not otherwise described and appling twocoats of synthetic enamel paint (ordinary tint) overone coats of pink primer, all as specified and directed. 56 M&L Peparation of old painted wooden surfaes of any dscription over 10cm width or girth and applying one coatof synthetic enamel paint complete all as specified and as directed. 57 M&L Peparation of old painted steel surfaces of any description over 10cmwidth or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. 58 M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash all as specified and directed. 59 M&L for preparation of old surfaces of ceiling and applying two coats of white washall as specified and directed. 60 M&L for preparation of new plastered surfaces of wall and applying three coats of white wash all as specified and directed. 61 M&L for preparation of old decorated plasteredsurfaces of wall and applying two coat of white wash all as specified and directed. 62 M&L for preparation of new plastered surfaces of wall and applying two coats oil bound distemper over a coat of alkali resistant primer over a coat of 1 mm thick wall care putty in two different layers complete all as specified & as directed.(Note - Treatment slall be carried our by spraying with mechanical means) 63 M&L for complete removal of existing treatment of wall and applying two coats oil bound distemper over a coat of alkali resistant primer over a coat of 1 mm thick wall care putty in two different layers complete all as specified & as directed.(Note - Treatment slall be carried our by spraying with mechanical means) 64 M&L for complete removing of existing treatment of wall surfaces by scrapping with mechanical sander (having mechanical vacuum mechanism)to make surface clean, free from dust, loose paint etc and applying two coat of cement base paint of different colours complete all as specified and directed. 65 M&L for preparation of new plastered surfaces of walls and applying two coat of cement base paint of any colours and pattern (two or more colours) complete all as specified and directed.(Note :- Colour and pattern of paint will be directed by GE) 66 M&L for PVC (SWR) pipe of 110 mm boresingle socketed in any length with rubber ring joint fixed to wall with suitable clamps of adequate numbers etc complete all as specified and directed. 67 S&FPVC SWR bends 110 mm boreall as specified and directed. 68 S&F Cast iron soil, waste pipe100 mm dia, sand cast, in any length with or without ear, with cement joint, laid in trenches, complete all as specified. 69 S&F Cast iron soil, wastepipe100 mm dia, sand cast, in any length with or without ear, with cement joint, laid in trenches, complete all as specified. 70 S&F Cast iron soil, waste and vent pipe100 mm dia, sand cast, in any length with or without ear, with cement joint, fixed on wall, complete all as specified. 71 S&F Cast iron soil, waste and vent pipe100 mm dia, sand cast, in any length with or without ear, with cement joint, fixed on wall, complete all as specified & directed. 72 S & F in repairs of 100 mm bore cast iron bends of any radius diminshing pieces or tappers (larger bore measured), all as specified & directed.. 73 S & F in repairs of 75 mm bore cast iron bends of any radius diminshing pieces or tappers (larger bore measured), all as specified & directed.. 74 S&F Cast iron cowls of 100 mm bore pipe, all as specified & directed. 75 S & F in repairs cast iron floor trap with chromium plated graating of 100 mm size including jointing to waste pipe with cement joints etc, all as specified & directed. 76 S&F Soap dish brass chromium plated decorative type, size 160X90mm complete all as specifed and directed. 77 S&F 600 mm X 450 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC buildg board or commercial plywood and fixed to wooden plugs with CPbrass screws and cup washers complete all as specified and directed. 78 S&F in repairBrass chromium plated, tubular towel rails 20 mm dia, D- type, 60cm long between flanges, completed all as specified and directed. 79 S&F in repair chromium plated 125 mm size shower rose with swivel joints, in square with CP long shank arm including fixing to steel pipe or union of 15 mm bore, complete all as specified and as directed. 80 S&F in repairs vitreous china squatting pan “Orissa Pattern” of size 580 x 440mm white with integral foot rest (excluding flushing cistern & flush pipe) including connection to trap and to flush pipes etc and lime concrete bedding complete all as specified in SSR and including S&F trap set complete all as specified and directed. 81 S&F in repairs PVC flushing cistern 10 ltr capacity valve less syphonic action type low level with and including dual flushball valve float & handle, waste pipe & brackets complete set complete all as specified and directed. 82 S & F in repairVitreous China wash basin, flat back, size 630X450mm white, excluding waste coupling, chain & plug, CI prackets, PVC waste pipe 32 mm,and porcelain stopper but including brackets. 83 S&F in repair chromium plated fancy type, stop cock/angular cock, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends of size 15mm bore. complete all as specified and directed. 84 S&F in repair chromium plated concealed type, stop valve, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends of size 15mm bore. complete all as specified and directed. 85 S & F in repair 15mm bore chromium plated bib tap, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron or brass ferrule, complete all as specified and directed. 86 S&F Sheet glass assembly consisting of 5.5mm thick sheet glass shelf 12mm wide with chromium plated bracket guard and railing, 600mm long,complete all as specified and directed. 87 S & F in repair Pillar taps fancy type(long body)cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, screwed for iron pipe, complete all as specified and directed. 88 S&F in repairPVC connections 15mm size with PTMT nuts of length 450 mm, complete all as specified and as directed. 89 S&Frotational moulded polythene water storage tank of capacity 500 ltrs (Cylindrical/vertical with closed top), triple layer construction, ISI marked, hoisted & fixed in position including followings :-(i)20 mm GI pipe medium grade,over flow 450mm long.(ii) 20 mm GI pipe medium grade waste pipe 600mm long.(iii) 20 mm brass ball valve/Float valves, high pressure & high density plastic ball screwed for iron pipe and fixed.(iv) 20 mm Gun metal globe/Gate valve with iron wheel head, screwed on both ends for fixing including one GI nipple(20mm bore). 90 S&F in repair sink with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and waste; including pvcwaste pipe, CP waste coupling,bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified anddirected. 91 S&F 1mm thick stainless steel kitchen plate rack of size 750x 900mm best quality assembled with brass washer and nut and bolts including hooks (spoon/cup holders) complete all as specified & directed. 92 Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level), all as specified & directed..Note : - All demolished items/ debris to be removed out side of MoD land. 93 Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for, all as specified & directed..Note : - All demolished items/ debris to be removed out side of MoD land. 94 Demolition of reinforced cement concrete of any description & in any position, complete all as specified and directed. 95 Dismantling of stone slabs and tiles of any description or thickness in floors aprons etc including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. 96 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises,all as specified and directed. 97 Taking down cement plaster on brick or stone walls, etc, incl raking out joints, hacking for key, scrubbing down with water, etc & prepare to receive new plaster complete all as specified and directed 98 Taking down chowkats or frame with shutter (without taking out shutter from the frame) not exceeding 1.50 sqm each and removal from site all as specified and directed. 99 Taking down chowkats or frame with shutter (without taking out shutter from the frame) exceeding 1.50 sqm and n exc 4.00 sqm each and removal from site all as specified and directed 100 Taking down of shutters of any description exc 1.00 Sqm but n. exc 2 Sqm each, all as specified and directed 101 Taiking up or down steel tubing and connections, 15 mm bore including cleaning, complete all as specified and directed. 102 Taiking up or down steel tubing and connections, 20 mm bore including cleaning, complete all as specified and directed. 103 Dismantling PVC water tankcapacity exceeding 250 but not exceeding 500 ltr, complete all as specified and directed. 104 Taking down100/75 mm cast iron soil waste pipe (any size or patterns) moulding all fittings heads shoes, bends etc (measured over all as fixed along the confrece line over fittings and accessories), all as specified and directed. 105 Taking down rain water pipes (any size or pattern) ,including all fittings all as specified and directted . 106 Demolition of bricks (laid flat or on edge) or brick tiles in floors, channels, kerbs, aprons, etc (each layer) laid, bedded and pointed in any mortar including removal of debris/muds etc complete all as specified and as directed.Note : - All demolished items/ debris to be removed out side of MoD land. 107 Demolition of mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) and finally cleaning the surface with wire brush to remove old treatment to lay PCC padding, complete all as specified and directed..Note : - All demolished items/ debris to be removed out side of MoD land 108 Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc, complete all as specified and directed. 109 Taking down old unserviceable MCB DB TPN4 way (Vertical), double door, 415 V, AC, 50 Hz, includingMCB63 Amps 16 KA ,IP-40 protection conforming to IS-13032 universal mounting with copper bus bar,neutral link, earth link, earthing studs, detachable gland plates with knockouts on both sides, complete all as specified & directed. 110 Material and labour for concealed point wring for One light/fan/exhaust fan point controlled by 1 No,one way 5/6 Amp switch ,using approved colour coding (Phase-red,Neutral-black,Earth-green) complete with FRLS PVC insulated and unshealthedstranded copper conductor cable 1.5 sqmm single coreconforming to IS 694 including medium duty concealed unplasticised PVC conduit conforming to IS 9537(part-3) and ISI marked not less than 20 mm dia with concealed in wall pressed steel terminal box of not less than 2 mm thick of required size including painting terminal boxs inside and outside with two coat of synthetic enamle paint over one coat of red oxide primerwith top cover3 mm thickbakelight laminated sheetwith brass screws and Cup washer with all assessories including FRLS PVC insulated and unshealthedstranded copper conductor cable 1.5 sqmm single core in green colouras earth wireconnected to earth dolly . complete all as specified and directed . 111 All as per Item No 110 above butfor One 3 pin /5 pin socket outlet 5 Amp controlled by 1 No one way 5/6 Amp switch on same board along with other switches ,fan regulator etc. 112 All as per Item No 110 above butfor One 3 pin /5 pin socket outlet 5 Amp controlled by 1 No one way 5/6 Amp switch on independent board. 113 All as per Item No 110 above butfor One call bell/buzzer point controlled by one push button switch. 114 Material and labour for point wring ,using approved colour coding (Phase-red,Neutral-black,Earth-green) complete for one socket outlet 15 Amp on independent board with FRLS PVC insulated and unshealthedstranded copper conductor cable 2.5 sqmm single coreconforming to IS 694 including medium duty concealed unplasticised PVC conduit conforming to IS 9537(part-3) and ISI marked not less than 20 mm dia with concealed in wall pressed steel terminal box of not less than 2 mm thick of required size including painting terminal boxs inside and outside with two coat of synthetic enamle paint over one coat of red oxide primerwith top cover3 mm thickbakelight laminated sheetwith brass screws and Cup washer with all assessories including FRLS PVC insulated and unshealthedstranded copper conductor cable 2.5 sqmm single core in green colouras earth wireconnected to earth dolly complete all as specified and directed. 115 S&F switch piano flush button single pole one way 5/6 Amp, 240 Volts conforming to IS 3854 ISI marked all as specified and directed. 116 S&Ffor socket outlet, 5 Pin, 5/6 Amp flush type conforming to IS 1293 ISI marked all as specified and directed. 117 S&F switch piano flush button single pole one way 15 Amp, 240 Volts conforming to IS 3854 ISI marked including taking down old one, all as specified and directed. 118 S&Ffor socket outlet, 3 Pin, 15 Amp flush type conforming to IS 1293 ISI marked including taking down old one, all as specified and directed. 119 S&Fceiling rose, surface Bakelite,isolated bodythree terminals including taking down old one, all as specified and directed. 120 S&F Lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings, all as specified and directed. 121 Supply only LED Bulb of 09 Watt complete all as specified and directed. 122 S&F forbell push flush type 5 A SP 240 V all as specified and directed. 123 S&FBell (Ding-Dong) 230 volts, single pole all as specified and directed. 124 Taking down ceiling fan including cable, dismantling blades and carry out mnr repair and fixing of damaged parts like capacitor, bushes, bearings and screws etc and keeping in safe custody of contractor up to re fixing in the same. all as specified & directed. 125 M&L for Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust, all as specified and directed. 126 Hanging only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan, all as specified and directed. 127 M & L for repair / rewinding of ceiling fand replacement of requisite spares like bush, bearing, down rod, capacitor, fan clamp, fan blade etc if necessary all as specified and directed. 128 M & L for repair / rewinding of exaust fand replacement of requisite spares like bush, bearing, capacitor, fan clamp, fan blade etc if necessary all as specified and directed. 129 Supply and fixing LED tube lights fitting 1x 18W, 220V, including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling roseand complete all as specified and directed. 130 Supply and fixing LED batten type tube light complete fitting 1x 10 W, 220V,connecting up with three core flexible copper conductor cable of suitable size from ceiling roseand complete all as specified and directed. 131 Supply &Fixing and connecting up complete MCB DB TPN 4 way (Vertical), double door, 415 V, AC, 50 Hz, with and includingMCB63 Amps 16 KA ,IP-40 protection conforming to IS-13032 universal mounting with copper bus bar,neutral link, earth link, earthing studs, detachable gland plates with knockouts on both sides, complete all as specified & directed. 132 S&F sheet metal enclosures (MCB Distribution board) when MCB’s to be used singlepole and neutral 8 ways 220 volt with 200 amps rated bus bar, double door with bus bar neutral link earth bar, Din rail, necessary blanking plated, including fixing DB flush in wall complete with making good disturbed surfaces and colour matching all as specified and directed including taking down old one, complete all as specified & directed. 133 S&F MCB’s single pole, 10 KA ,32 Amp to 40 Amp 240 Volts,and of B series with required wiring connections and lugs etc and erecting in provided enclouser/destribution board.MCBs shall be of current limiting type ,ISI marked conforming to IS 8828-1996, including taking down old one, complete all as specified & directed. 134 S&F Sheet metalenclosure with socket plug top and MCBs single pole with a two pin and earth plug andsocket complete with one single pole MCB ofC series of cap 20 Amps including taking out the old one all as specified and directed. 135 S&F MCB’s DP, 10 KA, 32 Amp to 40 Amp 240 Volts,and of B series with required wiring connections and lugs etc and erecting in provided enclouser/destribution board. MCBs shall be of current limiting type ,ISI marked conforming to IS 8828-1996,including taking down old one complete all as directed. 136 Supply and fixing STUD 10 W LED lights energy saving Bulk Head Luminaries including LED light driver, holder connecting up with three core flexible copper conductor cable of suitable size from ceiling roseand complete all as specified and directed. 137 S&F Sub main wiring using approved colour coding (Phase-red,Neutral-black,Earth-green) complete with two single core FRLS PVC insulated and unsheathedstranded copper conductor cable 6 sqmmas current carrying conductor and one run of 6.0 sqmm as neutral cable ,voltage rating 1100 volt ,ISI marked drawn in and including concealed PVC conduit ISI marked of dia not less than 25 mm and thickness 2 mm with stranded accessories along with one run of FRLS PVC green colour insulated,unshealthed,stranded copper conductor of size 6 sqmm all as specified and directedincluding taking down old one, complete all as specified and directed.(Note: Two run of single core FRLS PVC cable with one run of earth contunity conductor and conduit shall be measured as one unit.) 138 M&L for earthing complete with galvanized steel earth plate 600x600x6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead wire of 4mm dia as earthing lead by means of bolts, nuts, check-nuts, and washers of galvanised iron or steel besides welding at all joints as shown in drawings and including excavation and earth work, GI pipe light grade 15 mm bore for protection of GIwire from earth electrodeto test point /machinery / equipment.supplying and laying charcoal dustcomman saltPCC(1:2:4) type B1 using 20 mm gradedstone agregratechamber andRCC cover 54 cm X 54cm x50 mm thick (1:2:4) type B-1using 20 mm stone agrigrtae )reinforced with 8 mm dia TMT bars @75mm C/C both ways with mild steel handle 12 mm dia,using round bar ,PGI funnel with wire mesh, 20 mm dia GI pipe medium grade for watering all as shown in electrical plate No-3 of SSR part-1including testing and taking out the old one complete all as specified and directed(Note - Cost of GI wire and GI protection pipe up to a distance 7.5 M shall be includedin quated rate of above Items) 139 S&F 415 V, 10 KA ,B curve miniature circuit breaker MCB TPN 63 Amps, 16 KA complete all as specified and directed. 140 Supply, Laying, connecting and testing XLPE cable underground PVC insulated and over all sheathed with aluminium conductor heavy duty 1100 volts grade 3.5 core 35 sqmm sizes, laid in trenches, floors, ducts passing through pipe forroad crossing etc including taking down old UNSV cable of any size complete all as directed including taking out old damaged cable and all as specified and directed. (NOTE -excavation, earth work, brick protection sand cushioningand GI pipe etc shall be measured & paid for separately) 141 M&L for laying of bricks subclass ‘B’ old size having crushing strengh not s than 75 Kg/Sqcm, laid flat perpendicular to the direction of cable for protection of cable complete all as specified & directed. 142 M&L GI tubing 50 mm dia light grade, laid in trench/floor or fixed on wall with all fixingaccessories etc as specified and directed.