Tender For Upgradation Of Virology Lab Civil Work Approx 2860 Sq.Ft. Finishing With False Celling Glass, Wall Panelling, Apoxy Flooring, Electrical Work, Lighting Arrangement, Air Condition, Door Upgradation, Plumbing Work, Cctv, Smoke Detector, Required Furniture, Fire Extinguisher Etc. (As Per Map) Multipurpose Centrifuge i. Refrigerated multipurpose bench-top centrifuge 3 Lit capacity or more ii. System should be capable of using fixed angle and swing out rotors with adapter to use different tube formats iii. System should maintain temperature range-11°C to 40°C or better iv. System should have a maximum Capacity of 4 x 750 ml bottles or better v. Maximum speed for fixed angle rotors should be 14,000- 15,000 rpm and RCF 21-23,000 x g force, for swing out rotors maximum speed 5000 rpm or better and RCF 5,000 x RCF or better vi. System should have fast temperature function for rapid cooling of centrifuge and stand-by cooling options. vii. Should have programmable temperature function to allows automatic precooling based on pre-programmable time and date viii. System should 5 program keys for routine programs and at least 99 storable programs ix. The centrifuge must be equipped with automatic rotor recognition and imbalance detection for maximum operational safety x Timer-10s to 99 h 59 min, with continuous run function and short spin xi. System should have 10 acceleration and deceleration steps xii. Noise level at max speed should be less than 56 dB(A) for quite operation in work place xiii. System should have automatic shut off function to reduce energy consumption and to extend compressor life when not in use for long hours xiv. Rotors should be made of metallic and must be fully autoclavable at 121°C xv. Centrifuge lid with soft-touch lid closure, and low opening height for stress-free lid locking xvi. System must be ISO, European CE, or equivalent Certified. Rotors Swing out rotor for tubes, bottles upto 750ml with universal bucket design with speed 4,400 rpm or more and 4,300 x gor more with following adapter Adapter for 5ml x 60-64 ml nos, 15ml x 60-64 and MTP, DWP x 2-4 nos. Adapter for 50ml x 25-30 ml nos, 250ml bottle x 2- 4nos, and MTP, DWP x 2-4 nos 3 KVA Servo Controlled voltage stabilizer should be quoted. Refrigerated Micro Centrifuge Micro centrifuge with 18-places of 1.5/2.0 ml or better ii. Maximum Speed of between 16,000 to 17,000xg /13500- 14000 rpm, with a brushless motor iii. Instrument should have a maximum rotor capacity of 18 x 1.5/2ml. tubes or better iv. Temperature range of 0 deg C to 40 degC or better Rotor should be made of aluminium, rotor and rotor lids should be autoclavable at 121°C for 20 mins vi. Speed setting should be possible in both rpm and ref using a separate key vii. Instrument should have a quiet operation even when used without the rotor lid viii. Should possess a separate short spin key for brief spinning ix. Centrifuge lid should open automatically at the end of the run, to prevent sample warming It should be possible to operate the instrument in a cold room xi. Should have additional rotor options for micro centrifuge tubes and kit tubes xi. Instrument should have an automatic rotor recognition so that the rotor is automatically recognized and maximium speeds automatically adjusted xiii. It should be possible to perform gentle acceleration and deceleration using dedicated key xiv. Noise levels should be <55 db(A) Micropipettes Electronic multichannel (8 channel) i. Type: Electronic Multichannel Variable Volume for accurate and reproducibility result ii. Reproducibility: Adjusting the pipette to a certain altitude with spring loaded tip cone iii. Display: Modern color display: Self-explanatory display -No hidden functions iv. Applications: Pipetting liquids (manual and automatic), Pipetting and mixing, Dispensing (timed and manual) and Volume determination (manual pipetting) v. Battery: Powerful rechargeable Battery with long time usage without charging vi. History function: Automatically saves the last 10 sets of parameters vii. Volumes: 0.5-10 ul Manual Single Channel Basic: Adjustable volume of Micropipette with fully autoclavable ii. Micropipette should be Spring Loaded Tip Cone for connecting tips very tightly iii. Should have adjustment opening for adjusting pipettes to a specific liquid and volume. iv. Should have control Button with very low operating force, Color indication for pipette volume. v. Tip ejector with very low operating force, positioned for perfect ergonomics. vi. Volume Display: 4 Digits with magnifier. vii. To provide thermal, mechanical and chemical stability piston should manufactured from Fortron material. viii. Very easy removable lower part for cleaning pipette ix. Volume: 0.5-10 ul, 10-100 ul and 100-1000 ul Dry bath Dry bath system with Peltier driven thermal device for excellent temperature control with user controllable mixing function for complete, dependable and reproducible sample preparation System should have heating, mixing and cooling for tubes and plate formats with choice of blocks for 5 ul. to 50 ml. System should have both vortex and mixing functions. Vortex with radius of 15 mm and mixing speed ranging 300 to 3000 rpm iv. System should be programmable for temperature and time with capability to store 20 programs v. System should have a temperature control range from 15 C below RT to 100 °C with temperature settings ranging from 1 °C to 100 °C vi. System should have adjustable heating and cooling rate for proper optimization of incubation vii. System should be able to set from 15 sec to 99:30 h or continuous mode viii. System should have a large display to show set and actual parameters is. System should ensure prevention of lid wetting or cross- contamination x System should have provision for heated lid to prevent condensation on the lid xi. System should have maximum flexibility for user exchangeable blocks for various formats of tubes and platest si. System should possess automatic block recognition and set to its maximum speed limit xiii.System must be CE Certified xiv. System should have top cover to avoid condensate formation and sample evaporation. xv. System should be supplied with 1.5 X 24 block, and 15 X8 block and thermo cover Ultra-low temperature Freezer (-86 °C), Upright model, -80 deep freezer 700 L capacity or more iSystem should have Programmable operating temperature from-50°C up to-86°C with 1ºC increment Ⅲ Fully programmable microprocessor controlled with membrane keypad and eye level control panel. iv. Construction should be of Polyurethane foam insulation v. System should have touch screen display. vi. System should be resistant to scratch and rest and the interior should be Polished with 304 SS for easy cleaning and to eliminates potential for oxidation vii Inner door should have silicone seal to prevent temperature loss and Outer door should have safe silicone triple point seal. viii. Door opening recovery time should be less than 20 mins ix. Freezer should have at least 3 Compartment Ambient to -85 C pull down timing should be less than xi. Freezer must have battery back-up and Electronic Lock with personalize access codes xii. Freezer must have RS 485 interface data logging port and it must also have on board xiii. Noise level should be less than 43 dBA xiv. Audible and visible alarms for temperature, power failure, system failure, battery low etc and it also have remote alarm port for connection to an auto dialer. xv. Freezer must use CFC-FREE, HCFC-FREE flammable refrigerants, and refrigeration non xvi. system must be energy efficient and hermetically sealed two stage cascade refrigeration system. xvii. Freezer should have efficient power consumption should be less than 11 Kwh/Day xviii. Single phase Freezer should be supplied with 5KVA servo controlled voltage stabilizer Multichannel micropipettes i. Micropipette, Adjustable volume, fully autoclavable ii. Spring Loaded Tip Cone for connecting tips very tightly iii. Adjustment opening for adjusting pipettes to a specific liquid and volume. iv. Control Button with very low operating force, Color indication for pipette volume. v. Tip ejector with very low operating force, positioned for perfect ergonomics. vi. Volume Display: 4 Digits with magnifier. vii. To provide thermal, mechanical and chemical stability piston should manufactured from Fortron material viii. Very easy removable lower part for cleaning pipette ix. Fully Autoclavable x. Volume for single channel 0.5-10 µL,10-100 μL, 100-1000 L xi. 8 channel micropipette 10-100 ul, 30-300 ul Micropipettes Single channel L Micropipette, Adjustable volume, fully autoclavable ii. Spring Loaded Tip Cone for connecting tips very tightly iii. Adjustment opening for adjusting pipettes to a specific. liquid and volume.. iv. Control Button with very low operating force, Color indication for pipette volume. v. Tip ejector with very low operating force, positioned for perfect ergonomics. vi. Volume Display: 4 Digits with magnifier. vii. To provide thermal, mechanical and chemical stability piston should manufactured from Fortron material viii. Very easy removable lower part for cleaning pipette ix. Fully Autoclavable Volume for single channel 0.1-2.5ul, 0.5-10 μL,10-100 uL, 100-1000 μL

Tender Notice

38962660

Indian


Bihar

August 18, 2023

Key Value

Ref. Documents

Ref. Documents

Ref. Documents

To Download Tender Document Click on the below link

Tender For Upgradation Of Virology Lab Civil Work Approx 2860 Sq.Ft. Finishing With False Celling Glass, Wall Panelling, Apoxy Flooring, Electrical Work, Lighting Arrangement, Air Condition, Door Upgradation, Plumbing Work, Cctv, Smoke Detector, Required Furniture, Fire Extinguisher Etc. (As Per Map) Multipurpose Centrifuge i. Refrigerated multipurpose bench-top centrifuge 3 Lit capacity or more ii. System should be capable of using fixed angle and swing out rotors with adapter to use different tube formats iii. System should maintain temperature range-11°C to 40°C or better iv. System should have a maximum Capacity of 4 x 750 ml bottles or better v. Maximum speed for fixed angle rotors should be 14,000- 15,000 rpm and RCF 21-23,000 x g force, for swing out rotors maximum speed 5000 rpm or better and RCF 5,000 x RCF or better vi. System should have fast temperature function for rapid cooling of centrifuge and stand-by cooling options. vii. Should have programmable temperature function to allows automatic precooling based on pre-programmable time and date viii. System should 5 program keys for routine programs and at least 99 storable programs ix. The centrifuge must be equipped with automatic rotor recognition and imbalance detection for maximum operational safety x Timer-10s to 99 h 59 min, with continuous run function and short spin xi. System should have 10 acceleration and deceleration steps xii. Noise level at max speed should be less than 56 dB(A) for quite operation in work place xiii. System should have automatic shut off function to reduce energy consumption and to extend compressor life when not in use for long hours xiv. Rotors should be made of metallic and must be fully autoclavable at 121°C xv. Centrifuge lid with soft-touch lid closure, and low opening height for stress-free lid locking xvi. System must be ISO, European CE, or equivalent Certified. Rotors Swing out rotor for tubes, bottles upto 750ml with universal bucket design with speed 4,400 rpm or more and 4,300 x gor more with following adapter Adapter for 5ml x 60-64 ml nos, 15ml x 60-64 and MTP, DWP x 2-4 nos. Adapter for 50ml x 25-30 ml nos, 250ml bottle x 2- 4nos, and MTP, DWP x 2-4 nos 3 KVA Servo Controlled voltage stabilizer should be quoted. Refrigerated Micro Centrifuge Micro centrifuge with 18-places of 1.5/2.0 ml or better ii. Maximum Speed of between 16,000 to 17,000xg /13500- 14000 rpm, with a brushless motor iii. Instrument should have a maximum rotor capacity of 18 x 1.5/2ml. tubes or better iv. Temperature range of 0 deg C to 40 degC or better Rotor should be made of aluminium, rotor and rotor lids should be autoclavable at 121°C for 20 mins vi. Speed setting should be possible in both rpm and ref using a separate key vii. Instrument should have a quiet operation even when used without the rotor lid viii. Should possess a separate short spin key for brief spinning ix. Centrifuge lid should open automatically at the end of the run, to prevent sample warming It should be possible to operate the instrument in a cold room xi. Should have additional rotor options for micro centrifuge tubes and kit tubes xi. Instrument should have an automatic rotor recognition so that the rotor is automatically recognized and maximium speeds automatically adjusted xiii. It should be possible to perform gentle acceleration and deceleration using dedicated key xiv. Noise levels should be <55 db(A) Micropipettes Electronic multichannel (8 channel) i. Type: Electronic Multichannel Variable Volume for accurate and reproducibility result ii. Reproducibility: Adjusting the pipette to a certain altitude with spring loaded tip cone iii. Display: Modern color display: Self-explanatory display -No hidden functions iv. Applications: Pipetting liquids (manual and automatic), Pipetting and mixing, Dispensing (timed and manual) and Volume determination (manual pipetting) v. Battery: Powerful rechargeable Battery with long time usage without charging vi. History function: Automatically saves the last 10 sets of parameters vii. Volumes: 0.5-10 ul Manual Single Channel Basic: Adjustable volume of Micropipette with fully autoclavable ii. Micropipette should be Spring Loaded Tip Cone for connecting tips very tightly iii. Should have adjustment opening for adjusting pipettes to a specific liquid and volume. iv. Should have control Button with very low operating force, Color indication for pipette volume. v. Tip ejector with very low operating force, positioned for perfect ergonomics. vi. Volume Display: 4 Digits with magnifier. vii. To provide thermal, mechanical and chemical stability piston should manufactured from Fortron material. viii. Very easy removable lower part for cleaning pipette ix. Volume: 0.5-10 ul, 10-100 ul and 100-1000 ul Dry bath Dry bath system with Peltier driven thermal device for excellent temperature control with user controllable mixing function for complete, dependable and reproducible sample preparation System should have heating, mixing and cooling for tubes and plate formats with choice of blocks for 5 ul. to 50 ml. System should have both vortex and mixing functions. Vortex with radius of 15 mm and mixing speed ranging 300 to 3000 rpm iv. System should be programmable for temperature and time with capability to store 20 programs v. System should have a temperature control range from 15 C below RT to 100 °C with temperature settings ranging from 1 °C to 100 °C vi. System should have adjustable heating and cooling rate for proper optimization of incubation vii. System should be able to set from 15 sec to 99:30 h or continuous mode viii. System should have a large display to show set and actual parameters is. System should ensure prevention of lid wetting or cross- contamination x System should have provision for heated lid to prevent condensation on the lid xi. System should have maximum flexibility for user exchangeable blocks for various formats of tubes and platest si. System should possess automatic block recognition and set to its maximum speed limit xiii.System must be CE Certified xiv. System should have top cover to avoid condensate formation and sample evaporation. xv. System should be supplied with 1.5 X 24 block, and 15 X8 block and thermo cover Ultra-low temperature Freezer (-86 °C), Upright model, -80 deep freezer 700 L capacity or more iSystem should have Programmable operating temperature from-50°C up to-86°C with 1ºC increment Ⅲ Fully programmable microprocessor controlled with membrane keypad and eye level control panel. iv. Construction should be of Polyurethane foam insulation v. System should have touch screen display. vi. System should be resistant to scratch and rest and the interior should be Polished with 304 SS for easy cleaning and to eliminates potential for oxidation vii Inner door should have silicone seal to prevent temperature loss and Outer door should have safe silicone triple point seal. viii. Door opening recovery time should be less than 20 mins ix. Freezer should have at least 3 Compartment Ambient to -85 C pull down timing should be less than xi. Freezer must have battery back-up and Electronic Lock with personalize access codes xii. Freezer must have RS 485 interface data logging port and it must also have on board xiii. Noise level should be less than 43 dBA xiv. Audible and visible alarms for temperature, power failure, system failure, battery low etc and it also have remote alarm port for connection to an auto dialer. xv. Freezer must use CFC-FREE, HCFC-FREE flammable refrigerants, and refrigeration non xvi. system must be energy efficient and hermetically sealed two stage cascade refrigeration system. xvii. Freezer should have efficient power consumption should be less than 11 Kwh/Day xviii. Single phase Freezer should be supplied with 5KVA servo controlled voltage stabilizer Multichannel micropipettes i. Micropipette, Adjustable volume, fully autoclavable ii. Spring Loaded Tip Cone for connecting tips very tightly iii. Adjustment opening for adjusting pipettes to a specific liquid and volume. iv. Control Button with very low operating force, Color indication for pipette volume. v. Tip ejector with very low operating force, positioned for perfect ergonomics. vi. Volume Display: 4 Digits with magnifier. vii. To provide thermal, mechanical and chemical stability piston should manufactured from Fortron material viii. Very easy removable lower part for cleaning pipette ix. Fully Autoclavable x. Volume for single channel 0.5-10 µL,10-100 μL, 100-1000 L xi. 8 channel micropipette 10-100 ul, 30-300 ul Micropipettes Single channel L Micropipette, Adjustable volume, fully autoclavable ii. Spring Loaded Tip Cone for connecting tips very tightly iii. Adjustment opening for adjusting pipettes to a specific. liquid and volume.. iv. Control Button with very low operating force, Color indication for pipette volume. v. Tip ejector with very low operating force, positioned for perfect ergonomics. vi. Volume Display: 4 Digits with magnifier. vii. To provide thermal, mechanical and chemical stability piston should manufactured from Fortron material viii. Very easy removable lower part for cleaning pipette ix. Fully Autoclavable Volume for single channel 0.1-2.5ul, 0.5-10 μL,10-100 uL, 100-1000 μL