Tender For Electrical Works To Provide Power To Several Machine In The Department Of Mme; 1 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bellpoint With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductorsingle Core Cable In Surface / Recessed Medium Class Pvcconduit, With Modular Switch, Modular Plate, Suitable Gi Boxand Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulatedcopper Conductor Single Core Cable Etc. As Required. ( Group C ) Polycab / Rr Kabel / Kei 2 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire Sizes Of Frls Pvc Insulated Copper Conductor, Singlecore Cable In Surface / Recessed Medium Class Pvc Conduit Asrequired. Polycab / Rr Kabel / Kei 3 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The 2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required.Polycab / Rr Kabel / Kei 4 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The 4 X 10 Sq. Mm + 2 X 6 Sq. Mm Earth Wire Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required.Polycab / Rr Kabel / Kei 5 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The 4 X 6 Sq. Mm + 2 X 6 Sq. Mm Earth Wire Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required.Polycab / Rr Kabel / Kei 6 Providing And Fixing 100 A, 36Ka, Fp Mccb Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required.Legrand / Abb / L&T 7 Providing And Fixing 200 A, 36Ka, Fp Mccb Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required.Legrand / Abb / L&T 8 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Single Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Legrand / Abb / L&T 9 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Four Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Legrand / Abb / L&T 10 Supplying And Fixing 63 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Triple Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Legrand / Abb / L&T 11 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providng And Fixing 2 Nos. 3 Pin 5 / 6 A Modular Socket Outlet And 2 Nos. 5 / 6 A Modular Switch, Connections Etc. As Required. ( For Light Plugs To Be Used In Non Residential Buildings ) .Lrgrand Mylink / Equivalent 12 Supplying And Fixing Metal Sheet Enclosure Suitable For Four Pole Including Connection Etc. As Required.Legrand / Abb / L&T 13 Supplying And Fixing Suitable Size Pvc Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5 / 6 & 15 / 16 Amps Modular Socket Outlet And 15 / 16 Amps Modular Switch, Connection Etc. As Required. 14 Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For 3½ X 70 Sq. Mm ( 38 Mm ) Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.

Tender Notice

39051825

Indian


patna

Bihar

September 13, 2023

Key Value

1.98 Lakhs

1.98 Lakhs

1.98 Lakhs

To Download Tender Document Click on the below link

Tender For Electrical Works To Provide Power To Several Machine In The Department Of Mme; 1 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bellpoint With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductorsingle Core Cable In Surface / Recessed Medium Class Pvcconduit, With Modular Switch, Modular Plate, Suitable Gi Boxand Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulatedcopper Conductor Single Core Cable Etc. As Required. ( Group C ) Polycab / Rr Kabel / Kei 2 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire Sizes Of Frls Pvc Insulated Copper Conductor, Singlecore Cable In Surface / Recessed Medium Class Pvc Conduit Asrequired. Polycab / Rr Kabel / Kei 3 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The 2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required.Polycab / Rr Kabel / Kei 4 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The 4 X 10 Sq. Mm + 2 X 6 Sq. Mm Earth Wire Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required.Polycab / Rr Kabel / Kei 5 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The 4 X 6 Sq. Mm + 2 X 6 Sq. Mm Earth Wire Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required.Polycab / Rr Kabel / Kei 6 Providing And Fixing 100 A, 36Ka, Fp Mccb Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required.Legrand / Abb / L&T 7 Providing And Fixing 200 A, 36Ka, Fp Mccb Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required.Legrand / Abb / L&T 8 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Single Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Legrand / Abb / L&T 9 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Four Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Legrand / Abb / L&T 10 Supplying And Fixing 63 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Triple Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Legrand / Abb / L&T 11 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providng And Fixing 2 Nos. 3 Pin 5 / 6 A Modular Socket Outlet And 2 Nos. 5 / 6 A Modular Switch, Connections Etc. As Required. ( For Light Plugs To Be Used In Non Residential Buildings ) .Lrgrand Mylink / Equivalent 12 Supplying And Fixing Metal Sheet Enclosure Suitable For Four Pole Including Connection Etc. As Required.Legrand / Abb / L&T 13 Supplying And Fixing Suitable Size Pvc Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5 / 6 & 15 / 16 Amps Modular Socket Outlet And 15 / 16 Amps Modular Switch, Connection Etc. As Required. 14 Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For 3½ X 70 Sq. Mm ( 38 Mm ) Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.