Tender For Electrical Work In Old Building At Residential Complex Aiims Patna; 1 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface I Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gl Box And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. 2 Wiringfortwincontrollightpointwith 1.5Sq.Mmfrlspvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, 2 Way Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc .As Required. 3 Rewiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable And 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable As Earth Wireinexistingsurface / Recessedsteel / Pvc Conduit Including Dismantling As Required.Group C 4 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Steel Conduit As Required2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire 5 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Steel Conduit As Required 2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 6 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Steel Conduit As Required 2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire 7 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Steel Conduit As Required 2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire 8 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Steel Conduit As Required4 X 10 Sq. Mm + 2 X 6 Sq. Mm Earth Wire 9 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Steel Conduit As Required4 X 16 Sq. Mm + 2 X 6 Sq. Mm Earth Wire 10 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 3 X 1.5 Sq. Mm 11 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 3X4sq. Mm 12 Supplying And Fixing Metal Box Of Following Sizes ( Nominal Size ) On Surface Or In Recess With Suitable Size Of Phenolic Laminated Sheet Cover In Front Including Painting Etc. As Required.180 Mm X 100 Mm X 60 Mm 13 Supplying And Fixing Metal Box Of Following Sizes ( Nominal Size ) On Surface Or In Recess With Suitable Size Of Phenolic Laminated Sheet Cover In Front Including Painting Etc. As Required. 200 Mm X 125 Mm X 60 Mm 14 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 5 / 6 A Switch 15 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.15 / 16 A Switch 16 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 10 / 6 A Modular Socket Outlet 17 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 6 Pin 15 / 16 A Socket Outlet 18 Supplyingand Fixingtwo Module Steppedtypeelectronicfan Regulatorontheexistingmodularplateswitch Boxincluding Connections But Excluding Modular Plate Etc. As Required. 19 Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. 20 Supplying And Fixing Following Size / Modules, Gl Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required.3 Module ( 100Mmx75mm ) 21 Supplying And Fixing Following Size / Modules, Gl Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required.6 Module ( 200Mmx75mm ) 22 Supplying And Fixing Following Size / Modules, Gl Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. 8 Module ( 200Mmx75mm ) 23 Supplying And Fixing 3 Pin, 5 A Ceiling Rose On The Existing Junction Box / Wooden Block Including Connections Etc. As Required. 24 Supplying And Fixing Brass Batten / Angle Holder Including Connection Etc. As Required. 25 Installation, Testingandcommissioningofceilingfan, Including Wiring The Down Rods Of Standard Length ( Upto 30 Cm ) With 1.5 Sq. Mmfrlspvcinsulated, Copperconductor, Singlecorecable, Including Providing And Fixing Phenolic Laminated Sheet Cover On The Fan Box Etc. As Required. 26 Numberingofceilingfan / Exhaustfan / Fluorescentfittingsas Required. 27 Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage, Connection, Testing, Commissioning Etc. As Required.Upto 450 Mm Sweep 28 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcbirccb / Isolator ) 6 Way, Double Door 29 Supplying And Fixing Of Following Ways Surface / Recess Mounting, Vertical Type, 415 V, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 A Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting McbS ( But Without McbS And Incomer ) As Required.8 Way ( 4 + 24 ) , Double Door 30 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole 10 Amp 31 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole 20 Amp 32 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole 32 Amp 33 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Triple Pole And Neutral ( 32 Amp. ) 34 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Triple Pole And Neutral ( 63 Amp. ) 35 Supplying And Fixing Followingrating, Four Pole, ( Threephase And Neutral ) , 415 Volts, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30Ma In The Existingmcbdb Complete With Connections, Testing And Commissioning Etc. As Required. 63A 36 Supplying And Fixing Dp Sheet Steel Enclosure On Surface / Recess Along With 25 / 32 A 240 V C Curve Dp Mcb Complete With Connections, Testing And Commissioning Etc. As Required. 37 Supplying And Fixing 20 Amps, 240 Volts, Spn Industrial Type, Socket Outlet, With 2 Pole And Earth, Metal Enclosed Plug Top Alongwith 20 Amps “C” Curve, Sp, Mcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Out Let And Complete With Connections, Testing And Commissioning Etc. As Required. 38 Supplying And Fixing Cable End Box ( Loose Wire Box ) Suitable For Following Triple Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415Volts, Onsurface / Recess, Completewithtestingand Commissioning Etc.As Required. For 8 Way, Double Door Tpn Mcbdb 39 Earthing With Copper Earth Plate 600 Mm X 600 Mm X 3 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal / Coke And Salt As Required. 40 Providing And Fixing 25 Mm X 5 Mm Copper Strip On Surface Or In Recess For Connections Etc. As Required. 41 Providing And Fixing 25 Mm X 5 Mm G.I. Strip On Surface Or In Recess For Connections Etc. As Required. 42 Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current ( Bldc ) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2 Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value ( Cm / M / W ) Minimum 6.00, Air Delivery Minimum 210 Cum / Min , 350 Rpm ( Tolerance As Per Is : 374-2019 ) , Thd Less Than 10%, Remote Or Electronic Regulator Unit For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 Degree C ( Max. ) , Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc. Complete As Required. 43 Supplying And Fixing18 / 20 Watt Led Batten Light ( Syska / Crompton / Havells / Wipro ) 44 Supplying And Fixing20 Watt Led Down Light ( Squre ) ( Syska / Crompton / Havells / Wipro ) 45 Supplying And Fixing 40 / 36 Watt Led Down Light ( Squre ) ( Syska / Crompton / Havells / Wipro ) 46 Supplying And Fixing 300Mm 1350 Rpm 1 Phase Exhaust Fan ( Havells / Crompton ) Turbo Force 47 Supplying And Fixing 300W Flood Light With Lense ( Syska / Crompton / Havells / Wipro ) 48 Supplying And Fixing25mm Casing &Caping

Tender Notice

39409945

Indian


patna

Bihar

September 22, 2023

Key Value

56.44 Lakhs

56.44 Lakhs

56.44 Lakhs

To Download Tender Document Click on the below link

Tender For Electrical Work In Old Building At Residential Complex Aiims Patna; 1 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface I Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gl Box And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. 2 Wiringfortwincontrollightpointwith 1.5Sq.Mmfrlspvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, 2 Way Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc .As Required. 3 Rewiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable And 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable As Earth Wireinexistingsurface / Recessedsteel / Pvc Conduit Including Dismantling As Required.Group C 4 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Steel Conduit As Required2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire 5 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Steel Conduit As Required 2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 6 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Steel Conduit As Required 2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire 7 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Steel Conduit As Required 2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire 8 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Steel Conduit As Required4 X 10 Sq. Mm + 2 X 6 Sq. Mm Earth Wire 9 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Steel Conduit As Required4 X 16 Sq. Mm + 2 X 6 Sq. Mm Earth Wire 10 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 3 X 1.5 Sq. Mm 11 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 3X4sq. Mm 12 Supplying And Fixing Metal Box Of Following Sizes ( Nominal Size ) On Surface Or In Recess With Suitable Size Of Phenolic Laminated Sheet Cover In Front Including Painting Etc. As Required.180 Mm X 100 Mm X 60 Mm 13 Supplying And Fixing Metal Box Of Following Sizes ( Nominal Size ) On Surface Or In Recess With Suitable Size Of Phenolic Laminated Sheet Cover In Front Including Painting Etc. As Required. 200 Mm X 125 Mm X 60 Mm 14 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 5 / 6 A Switch 15 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.15 / 16 A Switch 16 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 10 / 6 A Modular Socket Outlet 17 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 6 Pin 15 / 16 A Socket Outlet 18 Supplyingand Fixingtwo Module Steppedtypeelectronicfan Regulatorontheexistingmodularplateswitch Boxincluding Connections But Excluding Modular Plate Etc. As Required. 19 Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. 20 Supplying And Fixing Following Size / Modules, Gl Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required.3 Module ( 100Mmx75mm ) 21 Supplying And Fixing Following Size / Modules, Gl Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required.6 Module ( 200Mmx75mm ) 22 Supplying And Fixing Following Size / Modules, Gl Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. 8 Module ( 200Mmx75mm ) 23 Supplying And Fixing 3 Pin, 5 A Ceiling Rose On The Existing Junction Box / Wooden Block Including Connections Etc. As Required. 24 Supplying And Fixing Brass Batten / Angle Holder Including Connection Etc. As Required. 25 Installation, Testingandcommissioningofceilingfan, Including Wiring The Down Rods Of Standard Length ( Upto 30 Cm ) With 1.5 Sq. Mmfrlspvcinsulated, Copperconductor, Singlecorecable, Including Providing And Fixing Phenolic Laminated Sheet Cover On The Fan Box Etc. As Required. 26 Numberingofceilingfan / Exhaustfan / Fluorescentfittingsas Required. 27 Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage, Connection, Testing, Commissioning Etc. As Required.Upto 450 Mm Sweep 28 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcbirccb / Isolator ) 6 Way, Double Door 29 Supplying And Fixing Of Following Ways Surface / Recess Mounting, Vertical Type, 415 V, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 A Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting McbS ( But Without McbS And Incomer ) As Required.8 Way ( 4 + 24 ) , Double Door 30 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole 10 Amp 31 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole 20 Amp 32 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole 32 Amp 33 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Triple Pole And Neutral ( 32 Amp. ) 34 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Triple Pole And Neutral ( 63 Amp. ) 35 Supplying And Fixing Followingrating, Four Pole, ( Threephase And Neutral ) , 415 Volts, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30Ma In The Existingmcbdb Complete With Connections, Testing And Commissioning Etc. As Required. 63A 36 Supplying And Fixing Dp Sheet Steel Enclosure On Surface / Recess Along With 25 / 32 A 240 V C Curve Dp Mcb Complete With Connections, Testing And Commissioning Etc. As Required. 37 Supplying And Fixing 20 Amps, 240 Volts, Spn Industrial Type, Socket Outlet, With 2 Pole And Earth, Metal Enclosed Plug Top Alongwith 20 Amps “C” Curve, Sp, Mcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Out Let And Complete With Connections, Testing And Commissioning Etc. As Required. 38 Supplying And Fixing Cable End Box ( Loose Wire Box ) Suitable For Following Triple Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415Volts, Onsurface / Recess, Completewithtestingand Commissioning Etc.As Required. For 8 Way, Double Door Tpn Mcbdb 39 Earthing With Copper Earth Plate 600 Mm X 600 Mm X 3 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal / Coke And Salt As Required. 40 Providing And Fixing 25 Mm X 5 Mm Copper Strip On Surface Or In Recess For Connections Etc. As Required. 41 Providing And Fixing 25 Mm X 5 Mm G.I. Strip On Surface Or In Recess For Connections Etc. As Required. 42 Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current ( Bldc ) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2 Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value ( Cm / M / W ) Minimum 6.00, Air Delivery Minimum 210 Cum / Min , 350 Rpm ( Tolerance As Per Is : 374-2019 ) , Thd Less Than 10%, Remote Or Electronic Regulator Unit For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 Degree C ( Max. ) , Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac Supply, Earthing Etc. Complete As Required. 43 Supplying And Fixing18 / 20 Watt Led Batten Light ( Syska / Crompton / Havells / Wipro ) 44 Supplying And Fixing20 Watt Led Down Light ( Squre ) ( Syska / Crompton / Havells / Wipro ) 45 Supplying And Fixing 40 / 36 Watt Led Down Light ( Squre ) ( Syska / Crompton / Havells / Wipro ) 46 Supplying And Fixing 300Mm 1350 Rpm 1 Phase Exhaust Fan ( Havells / Crompton ) Turbo Force 47 Supplying And Fixing 300W Flood Light With Lense ( Syska / Crompton / Havells / Wipro ) 48 Supplying And Fixing25mm Casing &Caping