Tender For Special Repair To Bldg No P-86 At Ota Gaya; 1 Demolition Of Cement Concrete ( Unreinforced ) In Ground Floors And Pavings N Exc 15 Cm Thickness ( Below Or Above Ground Level ) . 2 Demolition Of Brickwork Or Stone / Boulder Masonry, Built In Cement Mortar Including All Quoins, Arches, Pillars, Etc, But Excluding Ashlar Facings, Dressed Stonework And Precast Concrete Articles Complete All As Specified And Directed. 3 Taking Down Cement Plaster On Brick Or Stone Walls Etc, Including Racking Out Joints, Hacking For Key, Scrubbing Down With Water Etc. 4 Dismantling Floor, Hearth Or Wall Tilling Including Cement Mortar Bedding , Removing Serviceable Tiles To Store And Rubbish Off The Premises. 5 Taking Down Chowkat Or Frame With Shutter ( Without Taking Off Shutters From The Frames ) Areaexceeding 1.5 Sq Mtr But Not Exceeding 4 Sq Mtr Each 6 Taking Down Chowkhats Or Frames Not Exc. 1.5 Sq. M Each But With Shutters ( Without Taking Off Shutters From The Frames ) . 7 Dismantling Water Tanks Of Capacity Exc 500 & Not Exc 1000 Litres And Removing To Store. 8 Taking Up Or Down 15Mm Dia Bore Steel Tubing And Connections, Including Cleaning For Refixing Or Removal To Store. 9 Taking Up Or Down 20Mm Dia Bore Steel Tubing And Connections, Including Cleaning For Refixing Or Removal To Store. 10 Dismantling Of Asbestos Cement ( Corrugated, Semicorrugated, Etc. ) Sheets In Roof Coverings Complete. 11 Dismantling Wrought Iron Or Mild Steel Work Of Any Description Not Otherwise Provided For Complete. 12 Taking Down Eaves Gutters And Rainwater Pipes ( Any Size Or Pattern ) , Including All Fittings, Heads, Shoes, Bends, Swan-Necks, Etc., Including Cleaning Or Refixing Or Removal To Store ( Measured Overall As Fixed Along The Centre Line Over Fittings And Accessories ) 13 M & L For Providing 75 Mm Thick Pcc Type C-1, 1 : 3 : 6, ( Using 40 Mm Graded Aggregate ) As Sub Base Flooringand Finishing Surfaces Even And Smooth Without Using Extra Cement Complete. 14 M & L For Providing 50 Mm Thick Pcc Type C-2, 1 : 3 : 6, ( Using 40 Mm Graded Aggregate ) As Inplinth Protection And Drain Bed Complete All As Specified And Directed. 15 M & L For Providing Precast Cement Concrete 1:2:4 Type B-1 Using 20Mm Graded Stone Aggregate As In Landings, Cover Slabs ( For Man Holes Etc ) And Similar Work Including Necessary Formwork And Set In Cement Mortar 1:6Complete All As Specified And Directed. 16 M&L For Brick Work Using Sub Class B Old Bricks Straightor Curved On Plan Exc 6M Mean Radius Built In Cement Mortar 1:6 Complete All As Specified And Directed. 17 M&L For Brick Work Using Sub Class B Old Bricks ( Except Bricks ) Straightor Curved On Plan Exc 6M Mean Radius Built In Cement Mortar 1:6 Complete All As Specified And Directed. 18 M & L For 10 Mm Thick Rendering In Cement Mortar 1:6 On Fair Faces Of Brick Work Or Concrete Surfaces And Finishing The Surface Even And Smoth Without Using Extra Cement Complete All As Specified And Directed. Note : Chicken Wire Mesh Be Provided To The Joints Of Column And Beams During Rendering. 19 M & L For Rendering 15Mm Thick In Two Layerson External Surfaces On Brick / Concrete Surfaces In Cm 1:4 Finished Even And Smooth Without Using Extra Cement With Wpc. Note :- Wpc Measured And Paid Separatly Andchicken Wire Mesh Be Provided To The Joints Of Column And Beams During Rendering. 20 M & L For Rendering 10Mm Thick Internal Surfaces On Fair Faces Of Brick Or Concrete Surfaces In Cement Plaster 1:3 As In Ceiling And Finished Even And Smooth ( Without Using Extra Cement ) Complete. 21 Supply Only Liquid Water Proofing Compound ( Make : Sika Latex Power ) 22 Cutting Grooves In Brick Wall, 75Mm Wide And 65Mm Deep And Shaping Horizontal Face Of Groove With Finishing With Cement Mortar 1:3. 23 M & L For Non - Skid Ceramic Coloured Tiles 7 To 8 Mm Thick ( Square / Rectangular ) Area Of Each Tile Exceeding 0.11 Sqm But Not Exceeding 0.18 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over 15Mm Thick Screed Bed In Cm 1:4 Complete All As Specified And Directed. 24 M & L For Coloured Glazed Ceramic Tiles In Vertical Surface 450X300x 7Mm Thick Set And Jointed In Neat Cement Slurry And Pointed In White Or Colour Cement To Match Over 10 Mm Thick Screed Bed In Cm 1:3 Complete All As Specified And Directed. 25 M & L For Machine Pressed Chequered Cement Concrete Tiles 30Cm X 30Cm X 30Mm Thick With Grey Cement And Pigment Over 20 Mm Thick Screed Bed In Cement Mortar 1:4 Complete All As Specified And Directed. 26 M & L For Machine Pressed Precast Concrete Interlocking Paver Block Any Shape And Size Confirming To Is 15658-2006 Of 60 Mm Thickness, M-35 Grade With Grey Cement And Pigment Complete All As Specified And Directed. 27 Sand Filling Under Floors For Cushioning Including Watering And Consolidation Complete All As Specified And Directed. 28 M & L For 25Mm Thick Cement Concrete Type B-0, 1:2:4Using 12.50Mm Graded Stone Aggregate As In Levelling Course Complete All As Specified And Directed. 29 M & L For Providing Pcc Type B1, 1 : 2 : 4, ( Using 20 Mm Graded Aggregate ) As Incoping, And The Like Including Weathering, Slightly Rounded Or Chamfered Angles And Throating Complete All As Specified And Directed. 30 S & F Rolled Mild Steel In Joist, Channel, Angle, Or Tee Sections, Fixed Independently, Without Connecting Plates, Etc. ( Cut To Ordinary Lengths I.E. Within 20Mm Of The Length Indicated ) Confirming To Fe 410-W ( Gde-E-250 ) Quality-A Complete. 31 S & F Pre-Painted Galvatume Aluminum Zinc Coating Gi Based Corrugated Steel Sheet 0.50Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering / Cladding To Wall, Fixed With Self Tapping Screws As Specified. 32 S & F Solid Pvc Frame Of Size 50 Mm X 47 Mm Made Out Of 5 Mm Single Side Prelam Pvc Sheet & Edges Will Be Printed To Match With Prelam Sheet Rein Forced With Ms Square Tube Etc. 33 S & F Factory Made Solid Panel Pvc Door Shutter 30Mm ( Style ) Consisting Of Frame Made Out Of M.S Tubes For Top And Bottom Rails M.S Frame Shall Be Covered With Heat Moulded Plain Colour Pvc C Channel Having A Pvc Sheet Strip Of 20Mm Width Stuck Inside With Solvent Cement For Stiles And Plain Colour Pvc Sheets For Top Rail, Lock Rail And Bottom Rail On Either Side And As Gap Insert For Top Rail And Bottom Rail, Panelling Of Plain Colour Pvc Sheets To Be Fitted In The M.S Frame Welded / Sealed To The Stiles And Rails With Suitable Pvc Sheet Beading And Joined Together With Solvent Cement, Supplying And Fixing In The Frame 34 S & F Powder Coated Aluminium Section For Doors, Windows, Ventilators Sliding / Openable Etc With Joining Cleat For Fixing, Locking Arrangement, Rubber Beading, Screws, Etc Including Taking Down And Making The Surface Good Complete All As Specified.Make : Jindal / Hindalco / Indalco. Note : ( I ) Glazing And Wire Mesh Shall Be Measured And Paid Separetely. ( Ii ) Item Shall Be Paid As Per Weight Of Aluminium Section ( Iii ) The Rate Quoted Shall Be Inclusive Of The Cost Of Neoprene Beading, Glazing Pin, Screws And Powder Coated Fittings Such As Locking Arraangement Etc As Required, Which Shall Not Be Measured For Arriving The Weight ( Iv ) The Rate Shall Also Be Inclusive Of Complete Packing With Silicon Gel Around Contacting Surfaces Of Aluminium Work, And Including Matching The Existing. 35 S & F Framed Work Such As Grills, Gratings, Etc.. With Ends Of Bars Shouldered And / Or Riveted, Or Forged Into Spikes; Framed Guard Bars; Barred Iron Doors; Ladders; Framed Balusters; Walk Ways; Railings; Framework Of Water Tanks And Similar Work Conforming To Fe.290.Gde-E-165 Complete All As Specified And Directed. 36 Taking Down Existing Aluminium Door Or Window Shutter With Frame Area Exceeding 1 Sqm And Re-Fixing In Same Opening After Repair / Replace The Defective Jointing Cleats / Screws And Fittings Etc All As Per Specified And Directed By Engr-In-Charge. 37 S&F 100 Mm Long Stainless Steel Butt Hinges With Steel Hinge Pin Etc. 38 S&F 150 Mm Long Aluminium Anodised, Barrel Tower Bolts Of Extruded Section And 12 Mm Dia Fixed. 39 S&F 150Mm Long Aluminium Anodised Handle Cast Type And Fixed D Type 40 S&F250mm Long Aluminium Alloy, Anodised, Sliding Door Bolt With Hasp, Staple ( Bolt Type ) And Fixing Clips Of Sheet, Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Sections Or Cast-Aluminium Alloy And Fixedcomplete All As Specified. 41 S&F White Colour Rotational Three Layer Moulded Polyethylene Water Storage Tanks ( Cylinderical Vertical With Closed Top ) Capacity 1000 Ltrhoisted And Fixed In Position All As Specified And Directed. Make;- Sintex / Rotex / Polycon 42 S & F In Repair 25Mm Dia Bore Ball Brass Valves, High Pressure, With Polythene Float And Flynut Complete, Screwed For Iron Pipe Or Brass Ferrule And Fixed. 43 S & F In Repair 25Mm Dia Bore Cpvc Gate Valves With Handle Or Wheel Head, Screwed Both Ends For Pipe And Fixed. 44 S & F In Repair 20Mm Dia Bore Cpvc Gate Valves With Handle Or Wheel Head, Screwed Both Ends For Pipe And Fixed. 45 Supplying And Laying Of Cpvc Pipes 25Mm Outer Dia Sdr 11 & Plain Cpvc Sdr 11 Including All Fittings On Walls / Ceilings Or In Floors Including Necessary Cutting / Chasing Of Walls And Floors Complete All As Specified And Directed. 46 S & F 25Mm Bore Male Brass Threaded Adaptor ( Mta / Mbta ) Or Female Brass Threaded Adaptor ( Fta / Fbta ) Complete. 47 Supplying And Laying Of Cpvc Pipes 20Mm Outer Dia Sdr 11 & Plain Cpvc Sdr 11 Including All Fittings On Walls / Ceilings Or In Floors Including Necessary Cutting / Chasing Of Walls And Floors Complete All As Specified And Directed. 48 S & F 20Mm Bore Male Brass Threaded Adaptor ( Mta / Mbta ) Or Female Brass Threaded Adaptor ( Fta / Fbta ) Complete. 49 S & F 110Mm Bore Pvc ( Swr ) Pipes Single Socketed, In Any Length With Rubber Ring Joints, Laid In Trenches Or In Floors And Connecting With Manholes Or Disposal Place. 50 S & F 110Mm Dia Borepvc ( Swr ) Bends With Access Door All As Specified And As Directed. 51 S & F Of Pvc ( Swr ) Junction Single, ( Single T ) 110 Mm Bore Equal Or Unequal With Acess Door Complete. 52 S & F 110Mm Bore Pvc ( Swr ) Vent Cowl With Rubber Ring Joints, Fixed To Pipes All As Specified. 53 S & F 75Mm Bore Pvc ( Swr ) Pipes Single Socketed, In Any Length With Rubber Ring Joints, Laid In Trenches Or In Floors And Connecting With Manholes Or Disposal Place. 54 S & F 75Mm Dia Borepvc ( Swr ) Bends With Access Door All As Specified And As Directed. 55 S & F Of Pvc ( Swr ) Junction Single, ( Single T ) 75 Mm Bore Equal Or Unequal With Acess Door Complete. 56 S & F As In Repair Of Vitreous China Squatting Pan, ‘Orissa’ Pattern, Size 580 X 440 Mm White, With Integral Foot Rests Water Closet ( Squatt Pattern ) Complete Including Provision Of Lime Concrete Bedding Complete All As Specified And As Directed Make : Hindware / Parryware / Cera 57 S & F In Repair 10 Litre Capacity Pvc Valveless, Syphonic Action Type, Flushing Cistern, Low Level, White, With Inlet, Ball Valve, Float And Handle Including Brackets Complete. 58 S & F In Repair Vitreous China Wash Basin, White, Flat Back Of Size 550X400mmexcluding Taps, Waste, Chain And Plug And Porcelain Stopper But Including Brackets, Cutting For And Pinning In Ends Of Brackets Or Erecting Stand And Inclusive Of Fixing Of Supply And Waste Pipe And 32Mm Dia Chromium Plated Waste Fittings With Long Screwed Shanks And Fly-Nuts, Flange End Bedded In Red Lead Cement And Other End Fixed Complete All As Specified And Directed. ( Make-Parryware / Hindware / Jaquar ) 59 S & F Pvc Connections 15Mm Size With Ptmt Nuts Of Length 600Mm Complete. 60 S & F In Repair 6Mm Thick Looking Mirror Of 1St Quality Glass, Mounted On 6Mm Thick Commercial Plywood And Fixed To Wooden Plugs With Chromium Plated Brass Screws And Cup Washers Complete. ( Saint Gobain / Modifloat ) 61 S & F In Repair 15 Mm Dia Bore Fancy Type Chromium Plated Bib Taps, Cast Copper Alloy With Crutch Or Butterfly Handle, Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule And Fixed. 62 S & F In Repair 15 Mm Dia Bore Fancy Type Chromium Plated Two Way Bib Taps, Cast Copper Alloy With Crutch Or Butterfly Handle Screwed Down, High Pressure, Screwed Both Ends For Iron Pipe Or For Unions. 63 S & F In Repair 15 Mm Dia Bore Fancy Type Chromium Plated Stop Valves, Cast Copper Alloy, Screwed Down, High Pressure, With Crutch Or Butterfly Handle, Screwed Both Ends For Iron Pipe Or For Unions And Fixed. 64 Supply & Fix In Repair Brass Chromium Plated Pillar Tap Swan Neck Long Body Fancy Typefor Wash Hand Basin For Mixing Hot And Cold Water Screwed Down For Iron Pipes Suitable For 15Mm Bore Pipe Complete. 65 S & F In Repair Brass / Chromium Plated Tubular Towel Rail, 20Mm Dia, D Type, 60Cm Long Between Flanges Complete. 66 S & F In Repair Soap Dish, Any Type, Fixed To Plugs With Chromium Plated Brass Screws Complete. 67 S & F In Repair 125Mm Dia Stainless Steel Grating ( Double Q ) Fixed On Floor Trap / Nahani Trap In Cement Mortar 1:6, All As Specified And Directed. 68 Supply & Fix In Repair Brass Chromium Plated Wall Mixer ( 2 / 3 Hole ) With Provision For Connection To Shower Rose For Mixing Hot And Cold Water Screwed Down For Iron Pipes Suitable For 15Mm Bore Pipe Complete All As Specified And Directed. ( Make-Parryware / Prayag / Hindware ) 69 S & F In Repair Chromium Plated Shower Rose 15 Mm Size, 125Mm Long With 300 Mm Arms Including Fixing To Pipe Or Union Complete. ( Make : Jaguar / Parryware / Hindware ) 70 S & F In Repair Harrison Rails Ofbore 20-25Mm , Mild Steel, Chromium Plated Cut To Length As Required And Fixing With Brackets, Stops, Rollers, Finiales Etc Complete All As Specified And Directed. 71 M & L For 2 Mm Thick Of Birlawhite Putty / Jk White Wall Care Putty In Two Coats On New / Old Plastered Surfaces And Making The Surface Uniform & Smooth On Walls / Ceilings. 72 M & L For Preparing New Plastered Wall Surfaces And Distempering Two Coats On Walls With Distemper Oil Emulsion, White Or Tinted Over A Coat Of Chalk Whiting Complete All As Specified And Directed. 73 M & L For Preparing New Plastered Ceiling Surfaces And Distempering Two Coats On Ceilings With Distemper Oil Emulsion, White Or Tinted Over A Coat Of Chalk Whiting Complete All As Specified And Directed. 74 M & L For Preparation Of Old Plasteredsurfaces And Applying One Coat Of Acrylic Distemper On Walls Complete All As Specified And As Directed. 75 M & L For Preparation Of Old Plasteredsurfaces And Applying One Coat Of Acrylic Distemper In Ceilings Complete All As Specified And As Directed. 76 M & L For One Coat Of Exterior Emulsion Paint White Or Tinted On Walls Of Fascia Of Roof Or Chajjas On Old Decorated Prepared Plastered / Painted Surfaces Of Bldg All As Specified And Directed. Make : Asian Paints ( Brand-Ace ) / Berger Paint ( Brand - Walmasta ) / Nerolac Paint ( Suraksha Plus ) . 77 M & L For Two Coats Of Exterior Emulsion Paint White Or Tinted Over A Coat Of Primer On Walls Of Fascia Of Roof Or Chajjas On New Prepared Plastered Surfaces Of Bldg All As Specified And Directed. Make : Asian Paints ( Brand-Ace ) / Berger Paint ( Brand - Walmasta ) / Nerolac Paint ( Suraksha Plus ) . 78 M & L For One Coat Of Exterior Weather Proof Emulsion Paint Tinted On Walls Of Fascia Of Roof Or Chajjas On Old Painted Surfaces Brick, Stone, Concrete, Asbestos Cement Or Plaster On Old Decorated Prepared Plastered / Painted Surfaces Of Bldg All As Specified And Directed. Make : Asian Paints ( Apex ) / Berger Paint ( Brand - Weathercoat Smooth ) / Nerolac Paint ( Nerolac ) . 79 M & L Two Coat Of Syntetic Enamel Paint Overnewsteel Surface Of Any Description Over 10Cm In Width Or Grithnot Otherwise Describedover One Coat Red Oxide Primerincl Preparation Of Surfaces Complete. 80 S&F 4Mm Thick Sheet Glass, Ordinary Quality And Glazing With Oil Putty In A Square N Exc 0.5 Sq M In Each Pane. 81 S & F Of 4.00 Mm Thick Figured Glass, Pin Head Type And Glazing With Oil Putty In Squares N Exc 0.5 Sq. M In Each Pane Complete. 82 S & Fstainless Steel Wire Cloth 0.36 Mm Nominal Dia Of Wire And Average Width Of Aperature 1.40Mm And Fixed With Beeding / Staples Complete All As Specified And Directed. 83 M&L For Providing Water Proofing Treatment Over Cleaned Roof Surface With Super Thermo App Modified Polymeric Membrane Comprising Of Followings :- ( I ) . Complete Removal Of Existing Roof Treatment By Picking, Sweeping Clean And Washing Down With Water To Remove Dust Etc From Plastered / Roof Surface / Walls And Filling The Crackes With Sealing Compound Grade A . ( Ii ) Rendering / Screed Bed 15 Mm Thick In Cement Mortor ( 1:4 ) Mixed With Liquid Water Proofing Compound As Per ManufacturerS Instructions Andfinished The Surface Fair And Even. ( Iii ) Applying Evenly A Coat Of Bitumen Based Primer Conforming To Is-3384-1965 @ 0.30 Kg / Sqm. ( Iv ) Applying 3 Mm Thick App Modified Polymeric Membrane With Non Polyster Reinforcement Of Approved Make, Weight Not Less Than 3.50 Kg / Sqm Laid With Gas Torch And Fastedon Roof Surface With Roller. The Over Laps 100Mm And Shall Be Sealed By Torch Application As Per Manufacture Instructions Including Vertical Surfaces After Cutting Necessary Grooving And Making Good With Pcc 1:2:4 Type B-O With Sika Latex Power As Per Manufacture Instructions. ( V ) Applying Two Coats Of Bituminous Anticorrosive Multi Purposealuminium Coating ( Super Silver Shield ) @ 150 Gm / Sqm Per Coat Over Polymeric Membrene. Note :- Wpc Shall Be Measured And Paid Separately. 84 M&L For Conventional Rcc Septic Tank Designed To Carry Sewage And Sullage Water, Excavation In Any Type Of Soil, Pcc 1:4:8 Below Foundation, Rcc M-30 Design Mix In Walls, Base Slab, Baffle Walls And Roof Slab Including Beams Etc With Vent Shaft, Manhole Openings With Cover Connection Etc., Complete With Effective Depth Of 1.5 Meter And Overall Depth Of 3 Meter For 50 Users. 85 Soakage Wells Exc, In Ordinary Soil, Foundation In Pcc 1:3:6 Wells Of Honey Combed And Solid In M-25 Concrete , Incl Interlocking Chamber, Screen Chamber Brick Work In Cm, Rcc Cover Slab In M-25 / Rr Masonary / Filling With Brick Bats, Complete Of Size 2.4 Dia X 3.00 M Deep. 86 Taking Down Copper / Aluminium Point Wiring ( Light, Fan, Bell, Socketor Power ) Complete Including Fixture And Fittings Such As Switches, Ceiling Roses, Pendent, Regulators, Sockets, Light Fitting Etc. Removing Materials To Store For Keeping In Safe Custody Or For Taking Credit ( Credit A For Above Items Should Be Made As Per Condition Seperately ) And Making Good Distrubed Surfaces Ofwalls, Floors Etc Complete All As Specified And Directed At Site. 87 Taking Down Old / Unserviceable Distribution Board By Disconnection Of Electric Connection Carefully Spn Dbs / Tpn Dbs / Main Switch Including Old Unserviceable Mccbs / Mcbs, Isolators, Etc And Making Good To Disturbed Surface Complete All As Specified And Directed. 88 Taking Down Carefully Copper / Aluminium Sub Main Wiring Of Any Size Fromsurface / Concealed / Existing Conduit Of Any Height And Removing Materials At Site And Making Good Disturbed Surfaces Of Walls, Floors Roofs Etc Complete All As Specified And Directed. 89 Taking Down Ceiling Fan / Exhaust Fan Of Any Sweep After Disconnecting All Necessary Electrical Connections From Ceiling Rose To Fan, Fan Bladesand Deposit To Mes Store Yard Of Age E / M Complete All As Specified And As Directed. 90 M&L For Point Wiring With 1.5 Sq Mm Single Core Pvc Insulated Unsheathed Copper Frls Multi Stranded Conductor Cable In Andincluding Concealed Pvc Conduit Of Size 20 / 25Mm Isi Marked Inclusive Oftees, Bend, Elbows Etc Upto And Including Sunk In Anodized Pressed Steel Box For Housing Switch Socket Etc Withwhite Laminated 3 Mm Thick Hylam Sheet Cover Isi Marked Of Suitable Size Complete Including Pvc Insulated Multi Strandedcopper Conductor 1.5 Sq Mm Frls Cable As Earth Wire To Common Earth Dolly For Connection To Ceiling Rose To Earth Terminalincludingcutting, Chasses And Making Good Disturbed Surface To Match With Existing Finish With Plaster Complete All As Specified And Directed By Engr-In-Charge For Following :- 91 ( A ) One Light Point Controlled By One, One Way Switch 5 Amps 92 ( B ) One Fan Point / Exhaust Fan Point Controlled By One, One Way Switch 5 Amps And Regulator 93 ( C ) One 3 Point 5 Amps Switch Socket Outlet Point Controlled By One Switch On The Same Board. 94 ( D ) One 3 Pin 5 Amps Switch Socket Outlet Point Controlled By One Switch On Independent Board. 95 Description All As Per Item No 90 Here In Before Butusing 2.5 Sq Mm Single Core Copper Conductor Cable Of Multistranded Flame Retardant Pvc Insulated Unsheathed 1100 Volts Grade For 5 / 15 Amps Switch Socket Cobmination Point Including Necessary Running Of2.5 Sq Mm Copper Conductor Flame Retardant Pvc Wire As Earth Continuity Conductor Along With Wiring And Connecting To The Common Eath Dolly. 96 S & F Switch Piano Type Single Pole 5 Amp, 230 Volts Complete All As Specified And Directed. 97 S & F Switch Piano Type Single Pole 15 Amp, 230 Volts Complete All As Specified And Directed. 98 S & F Socket Outlet 2-In-1, 5 Pin, 5 Amp, 230 Volts Complete All As Specified And Directed. 99 S & F Socket Outlet 2-In-1, 5 Pin, 5 / 15 Amp, 230 Volts Complete All As Specified And Directed. 100 S & F Ceiling Rose, Surface Bakelite With 3 Terminals, Isimarked For Batten Fitting Complete. 101 S & F Stepped Type Electronic Fan Regulator Flushtype Complete All As Specified And Directed. 102 S & F Lamp Holder, Pvc / Polycarbonate Type With Back Plate Suitabl For Batten / Slanting Fittings Complete All As Specified And Directed. 103 M & L For Sub Main Wiring With Approved Colour Coding As Per Is With Two Single Core Pvc Insulated Frls Cable With Stranded Copper Conductor Of Size 6 Sq Mm Nominal Area And Drawing Into Suitable Size Of Pvc Non Metallic Rigid Heavy Duty Pvc Conduit Of White / Ivory Colour And Its Accessaries Isi Marked Heavy Duty Of Suitable Sizeincluding Concealed In Wall Etcone Run Of Pvc Insulated With 6.0 Sqmm ( Nominal Area ) Stranded Copper Conductor Frls Cable As Earth Wire Complete All As Specified And As Directed. Note:- Two Runs Of 6 Sqmm Cable, One Run Of 6 Sqmm Cable And One Run Of Pvc Conduit Will Be Measured As One Unit 104 S & F For Sheet Metal Enclosure Mcb Db Tpn 4 Way Vertical Type With 200 Amps Rated Bus Bar 415 Volts Double Door With Magnitic Locking System Including Necessary Provision For Inserting The Dbs In Wall By Cutting The Brick / Stone Masonary Etc And Making Good Of Distrubed Surface To Match With Existing Colour Of Wall Complete All As Specified And As Directed. 105 S & F For Sheet Metal Enclosure Mcb Db Spn 8 Way With 200 Amps Rated Bus Bar 240 Volts Double Door With Magnetic Locking System Including Necessary Provision For Inserting The Dbs In Wall By Cutting The Brick / Stone Masonary Etc And Making Good Of Distrubed Surface To Match With Existing Colour Of Wall Complete All As Specified And As Directed. 106 S & F Formcb Tripple Pole And Neutral Rated Capacity 63 Amps, 415 Volts Breaking Capacity 10 Ka, C Curve Complete All As Specified And As Directed. 107 S & F For Mcb Single Pole And Neutral Rated Capacity 32 Amps, 240 Volts Breaking Capacity 10 Ka, C Curve Complete All As Specified And As Directed. 108 S & Ffor Mcb Single Pole Rated Capacity 5 To 32 Amps, 240 Volts Breaking Capacity 10 Ka, C Curve Complete All As Specified And As Directed. 109 S & F For Ceiling Fan, 230 Volts, 1200 Mm Sweep With Service Value Of The Fan Shall Be Greater Than 6.1 As Per Bis With Necessary Accessories And Electrical Connections From Ceiling Rose To Fan Teriminal Complete All As Specified And As Directed. 110 S & F For Highly Efficient Led Bulbs, 10 W, Used As A Ready Replacement For Existing Gls / Cfl Direct Fit Lamp, In B-22 Cap Of Make Bajaj, Havells, Hpl Complete All As Specified And Directed 111 S & F Forled 10 Watts Batten Aluminium Extruded With Decorative End Caps Complete All As Specified And As Directed. Make- Bajaj Cat Part No Bclsb 10 Nw Or Its Equivallent Model In Wipro, Philips. 112 S & F For Wall Mounted Led Tube Light Fitting 20 Watts Batten For Surface Mounted, Anodized Extruded Aluminium Housing, High Transmissitivity Diffuser, High Lumen Ouputboxtype Fitting, 230 Volts And Intregrated Electronic Driverconnector Block Etc With Warranty Option Of 5 Years From Date Of Installation Complete With All Accessories Internally Pre Wired Andnecessary Mounting Arrangements, Provision Of New 3 Core Multistrandedcopper Conductor Of Size 23 / 0.193 From Ceiling Rose To Fitting Complete All As Specified And As Directed. 113 S & F Building Security Lightfitting 1 X 35 / 36 W Led New Generation Energy Saving & Environmental Friendly Long Life Led Street / Bldg Security Light Made Up Of Pressure Die Cast Aluminium Housing With Mid Power Led As Lighting Source And Pc Cover Having Top Opening Including Driver Compartment Driver With Ip66 Protection And Impact Resistance Of Ik07 Including With Suitable For 32Mm Dia Medium Grade G I Bracket Not Exc 1.5 Mtr Length Made To Shape & Fixing On Pole / Wall With 2 Nos Of Ms Clamp Including Necessary Connection From Lt Oh Line / Buildings 114 S & F For Energy Efficient Exhaust Fan Of 230 Mm Sweep Made Of Metal Body Ventil Air -Ds Type Complete With Louver With Bolts Nuts And Washers Size Of The Bolt 15 Cm Long 12 Mm Dia Embedded In The Wall Including Provision Of Pvc Flexible Copper Cable Of Size 23 / 0.0076 Two Core From Ceiling Rose To Exhaust Fan Forconnection And Making Suitable Size Ofhole To Existing Brick Wall For Fan Basecompelte All As Specifiedand Directed. ( Note : Cost Of Suitable Opening Wall For Fixing Exhaust Fan Is Deemed To Be Includedin Overall Rate Quoted ) . 115 Taking Down Existing Old Extg Unserviceable Lt Ug / Service Cable Of Any Description And Sizecomplete All As Specified And Directed. 116 Supply & Laying In Trenches / Laid In Floor / Duct / Drawn Through Conduitxlpe Insulated, Armoured, Heavy Duty Elecric Cable With Alluminium Conductor, 1100 Volt Grade Cross Sectional Area 25 Sqmm 4 Core. 117 Excavation In Trenches Not Exceeding 1.5 Mtrs Wide & Not Exceeding 1.5 Mtr In Depth In Soft Or Loose Soil & Getting Out Complete All As Per & Directed. 118 Returning Filling Including Spreading Levelling Watering & Well Ramming In Layers Not Exc 25 Cm 119 Removal Of Excavated Soil To A Distance Not Exc 50 M And Depositing Where Directed At A Level Not Exc 1.5 Mtr Above The Starting Point Complete All As Directed. 120 M & L For Laying Of Hdpe Double Wall Corrugated Pipes In Trench For Ug Cable Protection Conforming To Is-14930 Part-Ii With Ip-67 Having Outer Dia 50 Mm And Inner Dia Of 38 Mm Including Necessary Fittings Such As Couplers, Bends Etc Complete All As Specified And Directed. Make: Rex / Rudrax Polymers / Finolex 121 M & L For Earthing Complete With Galvanized Steel Earth Plate Electrode 60 Cm X 60 Cm X 6 Mm Thick Buried Directly In Ground Vertically ( Earth Pit Not Less Than 2.25M Deep Below Ground Level ) With Top Edge Of The Plate Not Less Than 1.50 Mtr Deep Below Normal Ground Level, Connecting To Gi Earth Wire 4Mm Dia By Means Of Bolts, Nuts, Check Nuts, And Washers Of Galvanized Iron Or Steel Including 15 Mm Dia. Medium Grade Protection Pipe For Earth Lead Complete With Charcoal And Common Salt Including Watering Arrangement With Galvanized Iron Pipe Light Grade 20 Mm Dia, Pcc Chamber, Ci Frame And Cover, Ms Funnel With Wire Mesh All As Shown In Electrical Plate No 3 Of Ssr Part I Including Excavation And Earthwork In Any Type Ofsoil / Strata And Testing On Completion. Note:- Gi Earth Wire 4 Mm Dia And 15 Mm Dia Protection Pipe Upto 7.5 Mtr From Earth Plate Is Deemed To Be Included In Rate Quoted.

Tender Notice

40135204

Military Engineer Services

Indian


gaya

Bihar

November 07, 2023

Key Value

Ref. Documents

Ref. Documents

Ref. Documents

To Download Tender Document Click on the below link

Tender For Special Repair To Bldg No P-86 At Ota Gaya; 1 Demolition Of Cement Concrete ( Unreinforced ) In Ground Floors And Pavings N Exc 15 Cm Thickness ( Below Or Above Ground Level ) . 2 Demolition Of Brickwork Or Stone / Boulder Masonry, Built In Cement Mortar Including All Quoins, Arches, Pillars, Etc, But Excluding Ashlar Facings, Dressed Stonework And Precast Concrete Articles Complete All As Specified And Directed. 3 Taking Down Cement Plaster On Brick Or Stone Walls Etc, Including Racking Out Joints, Hacking For Key, Scrubbing Down With Water Etc. 4 Dismantling Floor, Hearth Or Wall Tilling Including Cement Mortar Bedding , Removing Serviceable Tiles To Store And Rubbish Off The Premises. 5 Taking Down Chowkat Or Frame With Shutter ( Without Taking Off Shutters From The Frames ) Areaexceeding 1.5 Sq Mtr But Not Exceeding 4 Sq Mtr Each 6 Taking Down Chowkhats Or Frames Not Exc. 1.5 Sq. M Each But With Shutters ( Without Taking Off Shutters From The Frames ) . 7 Dismantling Water Tanks Of Capacity Exc 500 & Not Exc 1000 Litres And Removing To Store. 8 Taking Up Or Down 15Mm Dia Bore Steel Tubing And Connections, Including Cleaning For Refixing Or Removal To Store. 9 Taking Up Or Down 20Mm Dia Bore Steel Tubing And Connections, Including Cleaning For Refixing Or Removal To Store. 10 Dismantling Of Asbestos Cement ( Corrugated, Semicorrugated, Etc. ) Sheets In Roof Coverings Complete. 11 Dismantling Wrought Iron Or Mild Steel Work Of Any Description Not Otherwise Provided For Complete. 12 Taking Down Eaves Gutters And Rainwater Pipes ( Any Size Or Pattern ) , Including All Fittings, Heads, Shoes, Bends, Swan-Necks, Etc., Including Cleaning Or Refixing Or Removal To Store ( Measured Overall As Fixed Along The Centre Line Over Fittings And Accessories ) 13 M & L For Providing 75 Mm Thick Pcc Type C-1, 1 : 3 : 6, ( Using 40 Mm Graded Aggregate ) As Sub Base Flooringand Finishing Surfaces Even And Smooth Without Using Extra Cement Complete. 14 M & L For Providing 50 Mm Thick Pcc Type C-2, 1 : 3 : 6, ( Using 40 Mm Graded Aggregate ) As Inplinth Protection And Drain Bed Complete All As Specified And Directed. 15 M & L For Providing Precast Cement Concrete 1:2:4 Type B-1 Using 20Mm Graded Stone Aggregate As In Landings, Cover Slabs ( For Man Holes Etc ) And Similar Work Including Necessary Formwork And Set In Cement Mortar 1:6Complete All As Specified And Directed. 16 M&L For Brick Work Using Sub Class B Old Bricks Straightor Curved On Plan Exc 6M Mean Radius Built In Cement Mortar 1:6 Complete All As Specified And Directed. 17 M&L For Brick Work Using Sub Class B Old Bricks ( Except Bricks ) Straightor Curved On Plan Exc 6M Mean Radius Built In Cement Mortar 1:6 Complete All As Specified And Directed. 18 M & L For 10 Mm Thick Rendering In Cement Mortar 1:6 On Fair Faces Of Brick Work Or Concrete Surfaces And Finishing The Surface Even And Smoth Without Using Extra Cement Complete All As Specified And Directed. Note : Chicken Wire Mesh Be Provided To The Joints Of Column And Beams During Rendering. 19 M & L For Rendering 15Mm Thick In Two Layerson External Surfaces On Brick / Concrete Surfaces In Cm 1:4 Finished Even And Smooth Without Using Extra Cement With Wpc. Note :- Wpc Measured And Paid Separatly Andchicken Wire Mesh Be Provided To The Joints Of Column And Beams During Rendering. 20 M & L For Rendering 10Mm Thick Internal Surfaces On Fair Faces Of Brick Or Concrete Surfaces In Cement Plaster 1:3 As In Ceiling And Finished Even And Smooth ( Without Using Extra Cement ) Complete. 21 Supply Only Liquid Water Proofing Compound ( Make : Sika Latex Power ) 22 Cutting Grooves In Brick Wall, 75Mm Wide And 65Mm Deep And Shaping Horizontal Face Of Groove With Finishing With Cement Mortar 1:3. 23 M & L For Non - Skid Ceramic Coloured Tiles 7 To 8 Mm Thick ( Square / Rectangular ) Area Of Each Tile Exceeding 0.11 Sqm But Not Exceeding 0.18 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match Over 15Mm Thick Screed Bed In Cm 1:4 Complete All As Specified And Directed. 24 M & L For Coloured Glazed Ceramic Tiles In Vertical Surface 450X300x 7Mm Thick Set And Jointed In Neat Cement Slurry And Pointed In White Or Colour Cement To Match Over 10 Mm Thick Screed Bed In Cm 1:3 Complete All As Specified And Directed. 25 M & L For Machine Pressed Chequered Cement Concrete Tiles 30Cm X 30Cm X 30Mm Thick With Grey Cement And Pigment Over 20 Mm Thick Screed Bed In Cement Mortar 1:4 Complete All As Specified And Directed. 26 M & L For Machine Pressed Precast Concrete Interlocking Paver Block Any Shape And Size Confirming To Is 15658-2006 Of 60 Mm Thickness, M-35 Grade With Grey Cement And Pigment Complete All As Specified And Directed. 27 Sand Filling Under Floors For Cushioning Including Watering And Consolidation Complete All As Specified And Directed. 28 M & L For 25Mm Thick Cement Concrete Type B-0, 1:2:4Using 12.50Mm Graded Stone Aggregate As In Levelling Course Complete All As Specified And Directed. 29 M & L For Providing Pcc Type B1, 1 : 2 : 4, ( Using 20 Mm Graded Aggregate ) As Incoping, And The Like Including Weathering, Slightly Rounded Or Chamfered Angles And Throating Complete All As Specified And Directed. 30 S & F Rolled Mild Steel In Joist, Channel, Angle, Or Tee Sections, Fixed Independently, Without Connecting Plates, Etc. ( Cut To Ordinary Lengths I.E. Within 20Mm Of The Length Indicated ) Confirming To Fe 410-W ( Gde-E-250 ) Quality-A Complete. 31 S & F Pre-Painted Galvatume Aluminum Zinc Coating Gi Based Corrugated Steel Sheet 0.50Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering / Cladding To Wall, Fixed With Self Tapping Screws As Specified. 32 S & F Solid Pvc Frame Of Size 50 Mm X 47 Mm Made Out Of 5 Mm Single Side Prelam Pvc Sheet & Edges Will Be Printed To Match With Prelam Sheet Rein Forced With Ms Square Tube Etc. 33 S & F Factory Made Solid Panel Pvc Door Shutter 30Mm ( Style ) Consisting Of Frame Made Out Of M.S Tubes For Top And Bottom Rails M.S Frame Shall Be Covered With Heat Moulded Plain Colour Pvc C Channel Having A Pvc Sheet Strip Of 20Mm Width Stuck Inside With Solvent Cement For Stiles And Plain Colour Pvc Sheets For Top Rail, Lock Rail And Bottom Rail On Either Side And As Gap Insert For Top Rail And Bottom Rail, Panelling Of Plain Colour Pvc Sheets To Be Fitted In The M.S Frame Welded / Sealed To The Stiles And Rails With Suitable Pvc Sheet Beading And Joined Together With Solvent Cement, Supplying And Fixing In The Frame 34 S & F Powder Coated Aluminium Section For Doors, Windows, Ventilators Sliding / Openable Etc With Joining Cleat For Fixing, Locking Arrangement, Rubber Beading, Screws, Etc Including Taking Down And Making The Surface Good Complete All As Specified.Make : Jindal / Hindalco / Indalco. Note : ( I ) Glazing And Wire Mesh Shall Be Measured And Paid Separetely. ( Ii ) Item Shall Be Paid As Per Weight Of Aluminium Section ( Iii ) The Rate Quoted Shall Be Inclusive Of The Cost Of Neoprene Beading, Glazing Pin, Screws And Powder Coated Fittings Such As Locking Arraangement Etc As Required, Which Shall Not Be Measured For Arriving The Weight ( Iv ) The Rate Shall Also Be Inclusive Of Complete Packing With Silicon Gel Around Contacting Surfaces Of Aluminium Work, And Including Matching The Existing. 35 S & F Framed Work Such As Grills, Gratings, Etc.. With Ends Of Bars Shouldered And / Or Riveted, Or Forged Into Spikes; Framed Guard Bars; Barred Iron Doors; Ladders; Framed Balusters; Walk Ways; Railings; Framework Of Water Tanks And Similar Work Conforming To Fe.290.Gde-E-165 Complete All As Specified And Directed. 36 Taking Down Existing Aluminium Door Or Window Shutter With Frame Area Exceeding 1 Sqm And Re-Fixing In Same Opening After Repair / Replace The Defective Jointing Cleats / Screws And Fittings Etc All As Per Specified And Directed By Engr-In-Charge. 37 S&F 100 Mm Long Stainless Steel Butt Hinges With Steel Hinge Pin Etc. 38 S&F 150 Mm Long Aluminium Anodised, Barrel Tower Bolts Of Extruded Section And 12 Mm Dia Fixed. 39 S&F 150Mm Long Aluminium Anodised Handle Cast Type And Fixed D Type 40 S&F250mm Long Aluminium Alloy, Anodised, Sliding Door Bolt With Hasp, Staple ( Bolt Type ) And Fixing Clips Of Sheet, Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Sections Or Cast-Aluminium Alloy And Fixedcomplete All As Specified. 41 S&F White Colour Rotational Three Layer Moulded Polyethylene Water Storage Tanks ( Cylinderical Vertical With Closed Top ) Capacity 1000 Ltrhoisted And Fixed In Position All As Specified And Directed. Make;- Sintex / Rotex / Polycon 42 S & F In Repair 25Mm Dia Bore Ball Brass Valves, High Pressure, With Polythene Float And Flynut Complete, Screwed For Iron Pipe Or Brass Ferrule And Fixed. 43 S & F In Repair 25Mm Dia Bore Cpvc Gate Valves With Handle Or Wheel Head, Screwed Both Ends For Pipe And Fixed. 44 S & F In Repair 20Mm Dia Bore Cpvc Gate Valves With Handle Or Wheel Head, Screwed Both Ends For Pipe And Fixed. 45 Supplying And Laying Of Cpvc Pipes 25Mm Outer Dia Sdr 11 & Plain Cpvc Sdr 11 Including All Fittings On Walls / Ceilings Or In Floors Including Necessary Cutting / Chasing Of Walls And Floors Complete All As Specified And Directed. 46 S & F 25Mm Bore Male Brass Threaded Adaptor ( Mta / Mbta ) Or Female Brass Threaded Adaptor ( Fta / Fbta ) Complete. 47 Supplying And Laying Of Cpvc Pipes 20Mm Outer Dia Sdr 11 & Plain Cpvc Sdr 11 Including All Fittings On Walls / Ceilings Or In Floors Including Necessary Cutting / Chasing Of Walls And Floors Complete All As Specified And Directed. 48 S & F 20Mm Bore Male Brass Threaded Adaptor ( Mta / Mbta ) Or Female Brass Threaded Adaptor ( Fta / Fbta ) Complete. 49 S & F 110Mm Bore Pvc ( Swr ) Pipes Single Socketed, In Any Length With Rubber Ring Joints, Laid In Trenches Or In Floors And Connecting With Manholes Or Disposal Place. 50 S & F 110Mm Dia Borepvc ( Swr ) Bends With Access Door All As Specified And As Directed. 51 S & F Of Pvc ( Swr ) Junction Single, ( Single T ) 110 Mm Bore Equal Or Unequal With Acess Door Complete. 52 S & F 110Mm Bore Pvc ( Swr ) Vent Cowl With Rubber Ring Joints, Fixed To Pipes All As Specified. 53 S & F 75Mm Bore Pvc ( Swr ) Pipes Single Socketed, In Any Length With Rubber Ring Joints, Laid In Trenches Or In Floors And Connecting With Manholes Or Disposal Place. 54 S & F 75Mm Dia Borepvc ( Swr ) Bends With Access Door All As Specified And As Directed. 55 S & F Of Pvc ( Swr ) Junction Single, ( Single T ) 75 Mm Bore Equal Or Unequal With Acess Door Complete. 56 S & F As In Repair Of Vitreous China Squatting Pan, ‘Orissa’ Pattern, Size 580 X 440 Mm White, With Integral Foot Rests Water Closet ( Squatt Pattern ) Complete Including Provision Of Lime Concrete Bedding Complete All As Specified And As Directed Make : Hindware / Parryware / Cera 57 S & F In Repair 10 Litre Capacity Pvc Valveless, Syphonic Action Type, Flushing Cistern, Low Level, White, With Inlet, Ball Valve, Float And Handle Including Brackets Complete. 58 S & F In Repair Vitreous China Wash Basin, White, Flat Back Of Size 550X400mmexcluding Taps, Waste, Chain And Plug And Porcelain Stopper But Including Brackets, Cutting For And Pinning In Ends Of Brackets Or Erecting Stand And Inclusive Of Fixing Of Supply And Waste Pipe And 32Mm Dia Chromium Plated Waste Fittings With Long Screwed Shanks And Fly-Nuts, Flange End Bedded In Red Lead Cement And Other End Fixed Complete All As Specified And Directed. ( Make-Parryware / Hindware / Jaquar ) 59 S & F Pvc Connections 15Mm Size With Ptmt Nuts Of Length 600Mm Complete. 60 S & F In Repair 6Mm Thick Looking Mirror Of 1St Quality Glass, Mounted On 6Mm Thick Commercial Plywood And Fixed To Wooden Plugs With Chromium Plated Brass Screws And Cup Washers Complete. ( Saint Gobain / Modifloat ) 61 S & F In Repair 15 Mm Dia Bore Fancy Type Chromium Plated Bib Taps, Cast Copper Alloy With Crutch Or Butterfly Handle, Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule And Fixed. 62 S & F In Repair 15 Mm Dia Bore Fancy Type Chromium Plated Two Way Bib Taps, Cast Copper Alloy With Crutch Or Butterfly Handle Screwed Down, High Pressure, Screwed Both Ends For Iron Pipe Or For Unions. 63 S & F In Repair 15 Mm Dia Bore Fancy Type Chromium Plated Stop Valves, Cast Copper Alloy, Screwed Down, High Pressure, With Crutch Or Butterfly Handle, Screwed Both Ends For Iron Pipe Or For Unions And Fixed. 64 Supply & Fix In Repair Brass Chromium Plated Pillar Tap Swan Neck Long Body Fancy Typefor Wash Hand Basin For Mixing Hot And Cold Water Screwed Down For Iron Pipes Suitable For 15Mm Bore Pipe Complete. 65 S & F In Repair Brass / Chromium Plated Tubular Towel Rail, 20Mm Dia, D Type, 60Cm Long Between Flanges Complete. 66 S & F In Repair Soap Dish, Any Type, Fixed To Plugs With Chromium Plated Brass Screws Complete. 67 S & F In Repair 125Mm Dia Stainless Steel Grating ( Double Q ) Fixed On Floor Trap / Nahani Trap In Cement Mortar 1:6, All As Specified And Directed. 68 Supply & Fix In Repair Brass Chromium Plated Wall Mixer ( 2 / 3 Hole ) With Provision For Connection To Shower Rose For Mixing Hot And Cold Water Screwed Down For Iron Pipes Suitable For 15Mm Bore Pipe Complete All As Specified And Directed. ( Make-Parryware / Prayag / Hindware ) 69 S & F In Repair Chromium Plated Shower Rose 15 Mm Size, 125Mm Long With 300 Mm Arms Including Fixing To Pipe Or Union Complete. ( Make : Jaguar / Parryware / Hindware ) 70 S & F In Repair Harrison Rails Ofbore 20-25Mm , Mild Steel, Chromium Plated Cut To Length As Required And Fixing With Brackets, Stops, Rollers, Finiales Etc Complete All As Specified And Directed. 71 M & L For 2 Mm Thick Of Birlawhite Putty / Jk White Wall Care Putty In Two Coats On New / Old Plastered Surfaces And Making The Surface Uniform & Smooth On Walls / Ceilings. 72 M & L For Preparing New Plastered Wall Surfaces And Distempering Two Coats On Walls With Distemper Oil Emulsion, White Or Tinted Over A Coat Of Chalk Whiting Complete All As Specified And Directed. 73 M & L For Preparing New Plastered Ceiling Surfaces And Distempering Two Coats On Ceilings With Distemper Oil Emulsion, White Or Tinted Over A Coat Of Chalk Whiting Complete All As Specified And Directed. 74 M & L For Preparation Of Old Plasteredsurfaces And Applying One Coat Of Acrylic Distemper On Walls Complete All As Specified And As Directed. 75 M & L For Preparation Of Old Plasteredsurfaces And Applying One Coat Of Acrylic Distemper In Ceilings Complete All As Specified And As Directed. 76 M & L For One Coat Of Exterior Emulsion Paint White Or Tinted On Walls Of Fascia Of Roof Or Chajjas On Old Decorated Prepared Plastered / Painted Surfaces Of Bldg All As Specified And Directed. Make : Asian Paints ( Brand-Ace ) / Berger Paint ( Brand - Walmasta ) / Nerolac Paint ( Suraksha Plus ) . 77 M & L For Two Coats Of Exterior Emulsion Paint White Or Tinted Over A Coat Of Primer On Walls Of Fascia Of Roof Or Chajjas On New Prepared Plastered Surfaces Of Bldg All As Specified And Directed. Make : Asian Paints ( Brand-Ace ) / Berger Paint ( Brand - Walmasta ) / Nerolac Paint ( Suraksha Plus ) . 78 M & L For One Coat Of Exterior Weather Proof Emulsion Paint Tinted On Walls Of Fascia Of Roof Or Chajjas On Old Painted Surfaces Brick, Stone, Concrete, Asbestos Cement Or Plaster On Old Decorated Prepared Plastered / Painted Surfaces Of Bldg All As Specified And Directed. Make : Asian Paints ( Apex ) / Berger Paint ( Brand - Weathercoat Smooth ) / Nerolac Paint ( Nerolac ) . 79 M & L Two Coat Of Syntetic Enamel Paint Overnewsteel Surface Of Any Description Over 10Cm In Width Or Grithnot Otherwise Describedover One Coat Red Oxide Primerincl Preparation Of Surfaces Complete. 80 S&F 4Mm Thick Sheet Glass, Ordinary Quality And Glazing With Oil Putty In A Square N Exc 0.5 Sq M In Each Pane. 81 S & F Of 4.00 Mm Thick Figured Glass, Pin Head Type And Glazing With Oil Putty In Squares N Exc 0.5 Sq. M In Each Pane Complete. 82 S & Fstainless Steel Wire Cloth 0.36 Mm Nominal Dia Of Wire And Average Width Of Aperature 1.40Mm And Fixed With Beeding / Staples Complete All As Specified And Directed. 83 M&L For Providing Water Proofing Treatment Over Cleaned Roof Surface With Super Thermo App Modified Polymeric Membrane Comprising Of Followings :- ( I ) . Complete Removal Of Existing Roof Treatment By Picking, Sweeping Clean And Washing Down With Water To Remove Dust Etc From Plastered / Roof Surface / Walls And Filling The Crackes With Sealing Compound Grade A . ( Ii ) Rendering / Screed Bed 15 Mm Thick In Cement Mortor ( 1:4 ) Mixed With Liquid Water Proofing Compound As Per ManufacturerS Instructions Andfinished The Surface Fair And Even. ( Iii ) Applying Evenly A Coat Of Bitumen Based Primer Conforming To Is-3384-1965 @ 0.30 Kg / Sqm. ( Iv ) Applying 3 Mm Thick App Modified Polymeric Membrane With Non Polyster Reinforcement Of Approved Make, Weight Not Less Than 3.50 Kg / Sqm Laid With Gas Torch And Fastedon Roof Surface With Roller. The Over Laps 100Mm And Shall Be Sealed By Torch Application As Per Manufacture Instructions Including Vertical Surfaces After Cutting Necessary Grooving And Making Good With Pcc 1:2:4 Type B-O With Sika Latex Power As Per Manufacture Instructions. ( V ) Applying Two Coats Of Bituminous Anticorrosive Multi Purposealuminium Coating ( Super Silver Shield ) @ 150 Gm / Sqm Per Coat Over Polymeric Membrene. Note :- Wpc Shall Be Measured And Paid Separately. 84 M&L For Conventional Rcc Septic Tank Designed To Carry Sewage And Sullage Water, Excavation In Any Type Of Soil, Pcc 1:4:8 Below Foundation, Rcc M-30 Design Mix In Walls, Base Slab, Baffle Walls And Roof Slab Including Beams Etc With Vent Shaft, Manhole Openings With Cover Connection Etc., Complete With Effective Depth Of 1.5 Meter And Overall Depth Of 3 Meter For 50 Users. 85 Soakage Wells Exc, In Ordinary Soil, Foundation In Pcc 1:3:6 Wells Of Honey Combed And Solid In M-25 Concrete , Incl Interlocking Chamber, Screen Chamber Brick Work In Cm, Rcc Cover Slab In M-25 / Rr Masonary / Filling With Brick Bats, Complete Of Size 2.4 Dia X 3.00 M Deep. 86 Taking Down Copper / Aluminium Point Wiring ( Light, Fan, Bell, Socketor Power ) Complete Including Fixture And Fittings Such As Switches, Ceiling Roses, Pendent, Regulators, Sockets, Light Fitting Etc. Removing Materials To Store For Keeping In Safe Custody Or For Taking Credit ( Credit A For Above Items Should Be Made As Per Condition Seperately ) And Making Good Distrubed Surfaces Ofwalls, Floors Etc Complete All As Specified And Directed At Site. 87 Taking Down Old / Unserviceable Distribution Board By Disconnection Of Electric Connection Carefully Spn Dbs / Tpn Dbs / Main Switch Including Old Unserviceable Mccbs / Mcbs, Isolators, Etc And Making Good To Disturbed Surface Complete All As Specified And Directed. 88 Taking Down Carefully Copper / Aluminium Sub Main Wiring Of Any Size Fromsurface / Concealed / Existing Conduit Of Any Height And Removing Materials At Site And Making Good Disturbed Surfaces Of Walls, Floors Roofs Etc Complete All As Specified And Directed. 89 Taking Down Ceiling Fan / Exhaust Fan Of Any Sweep After Disconnecting All Necessary Electrical Connections From Ceiling Rose To Fan, Fan Bladesand Deposit To Mes Store Yard Of Age E / M Complete All As Specified And As Directed. 90 M&L For Point Wiring With 1.5 Sq Mm Single Core Pvc Insulated Unsheathed Copper Frls Multi Stranded Conductor Cable In Andincluding Concealed Pvc Conduit Of Size 20 / 25Mm Isi Marked Inclusive Oftees, Bend, Elbows Etc Upto And Including Sunk In Anodized Pressed Steel Box For Housing Switch Socket Etc Withwhite Laminated 3 Mm Thick Hylam Sheet Cover Isi Marked Of Suitable Size Complete Including Pvc Insulated Multi Strandedcopper Conductor 1.5 Sq Mm Frls Cable As Earth Wire To Common Earth Dolly For Connection To Ceiling Rose To Earth Terminalincludingcutting, Chasses And Making Good Disturbed Surface To Match With Existing Finish With Plaster Complete All As Specified And Directed By Engr-In-Charge For Following :- 91 ( A ) One Light Point Controlled By One, One Way Switch 5 Amps 92 ( B ) One Fan Point / Exhaust Fan Point Controlled By One, One Way Switch 5 Amps And Regulator 93 ( C ) One 3 Point 5 Amps Switch Socket Outlet Point Controlled By One Switch On The Same Board. 94 ( D ) One 3 Pin 5 Amps Switch Socket Outlet Point Controlled By One Switch On Independent Board. 95 Description All As Per Item No 90 Here In Before Butusing 2.5 Sq Mm Single Core Copper Conductor Cable Of Multistranded Flame Retardant Pvc Insulated Unsheathed 1100 Volts Grade For 5 / 15 Amps Switch Socket Cobmination Point Including Necessary Running Of2.5 Sq Mm Copper Conductor Flame Retardant Pvc Wire As Earth Continuity Conductor Along With Wiring And Connecting To The Common Eath Dolly. 96 S & F Switch Piano Type Single Pole 5 Amp, 230 Volts Complete All As Specified And Directed. 97 S & F Switch Piano Type Single Pole 15 Amp, 230 Volts Complete All As Specified And Directed. 98 S & F Socket Outlet 2-In-1, 5 Pin, 5 Amp, 230 Volts Complete All As Specified And Directed. 99 S & F Socket Outlet 2-In-1, 5 Pin, 5 / 15 Amp, 230 Volts Complete All As Specified And Directed. 100 S & F Ceiling Rose, Surface Bakelite With 3 Terminals, Isimarked For Batten Fitting Complete. 101 S & F Stepped Type Electronic Fan Regulator Flushtype Complete All As Specified And Directed. 102 S & F Lamp Holder, Pvc / Polycarbonate Type With Back Plate Suitabl For Batten / Slanting Fittings Complete All As Specified And Directed. 103 M & L For Sub Main Wiring With Approved Colour Coding As Per Is With Two Single Core Pvc Insulated Frls Cable With Stranded Copper Conductor Of Size 6 Sq Mm Nominal Area And Drawing Into Suitable Size Of Pvc Non Metallic Rigid Heavy Duty Pvc Conduit Of White / Ivory Colour And Its Accessaries Isi Marked Heavy Duty Of Suitable Sizeincluding Concealed In Wall Etcone Run Of Pvc Insulated With 6.0 Sqmm ( Nominal Area ) Stranded Copper Conductor Frls Cable As Earth Wire Complete All As Specified And As Directed. Note:- Two Runs Of 6 Sqmm Cable, One Run Of 6 Sqmm Cable And One Run Of Pvc Conduit Will Be Measured As One Unit 104 S & F For Sheet Metal Enclosure Mcb Db Tpn 4 Way Vertical Type With 200 Amps Rated Bus Bar 415 Volts Double Door With Magnitic Locking System Including Necessary Provision For Inserting The Dbs In Wall By Cutting The Brick / Stone Masonary Etc And Making Good Of Distrubed Surface To Match With Existing Colour Of Wall Complete All As Specified And As Directed. 105 S & F For Sheet Metal Enclosure Mcb Db Spn 8 Way With 200 Amps Rated Bus Bar 240 Volts Double Door With Magnetic Locking System Including Necessary Provision For Inserting The Dbs In Wall By Cutting The Brick / Stone Masonary Etc And Making Good Of Distrubed Surface To Match With Existing Colour Of Wall Complete All As Specified And As Directed. 106 S & F Formcb Tripple Pole And Neutral Rated Capacity 63 Amps, 415 Volts Breaking Capacity 10 Ka, C Curve Complete All As Specified And As Directed. 107 S & F For Mcb Single Pole And Neutral Rated Capacity 32 Amps, 240 Volts Breaking Capacity 10 Ka, C Curve Complete All As Specified And As Directed. 108 S & Ffor Mcb Single Pole Rated Capacity 5 To 32 Amps, 240 Volts Breaking Capacity 10 Ka, C Curve Complete All As Specified And As Directed. 109 S & F For Ceiling Fan, 230 Volts, 1200 Mm Sweep With Service Value Of The Fan Shall Be Greater Than 6.1 As Per Bis With Necessary Accessories And Electrical Connections From Ceiling Rose To Fan Teriminal Complete All As Specified And As Directed. 110 S & F For Highly Efficient Led Bulbs, 10 W, Used As A Ready Replacement For Existing Gls / Cfl Direct Fit Lamp, In B-22 Cap Of Make Bajaj, Havells, Hpl Complete All As Specified And Directed 111 S & F Forled 10 Watts Batten Aluminium Extruded With Decorative End Caps Complete All As Specified And As Directed. Make- Bajaj Cat Part No Bclsb 10 Nw Or Its Equivallent Model In Wipro, Philips. 112 S & F For Wall Mounted Led Tube Light Fitting 20 Watts Batten For Surface Mounted, Anodized Extruded Aluminium Housing, High Transmissitivity Diffuser, High Lumen Ouputboxtype Fitting, 230 Volts And Intregrated Electronic Driverconnector Block Etc With Warranty Option Of 5 Years From Date Of Installation Complete With All Accessories Internally Pre Wired Andnecessary Mounting Arrangements, Provision Of New 3 Core Multistrandedcopper Conductor Of Size 23 / 0.193 From Ceiling Rose To Fitting Complete All As Specified And As Directed. 113 S & F Building Security Lightfitting 1 X 35 / 36 W Led New Generation Energy Saving & Environmental Friendly Long Life Led Street / Bldg Security Light Made Up Of Pressure Die Cast Aluminium Housing With Mid Power Led As Lighting Source And Pc Cover Having Top Opening Including Driver Compartment Driver With Ip66 Protection And Impact Resistance Of Ik07 Including With Suitable For 32Mm Dia Medium Grade G I Bracket Not Exc 1.5 Mtr Length Made To Shape & Fixing On Pole / Wall With 2 Nos Of Ms Clamp Including Necessary Connection From Lt Oh Line / Buildings 114 S & F For Energy Efficient Exhaust Fan Of 230 Mm Sweep Made Of Metal Body Ventil Air -Ds Type Complete With Louver With Bolts Nuts And Washers Size Of The Bolt 15 Cm Long 12 Mm Dia Embedded In The Wall Including Provision Of Pvc Flexible Copper Cable Of Size 23 / 0.0076 Two Core From Ceiling Rose To Exhaust Fan Forconnection And Making Suitable Size Ofhole To Existing Brick Wall For Fan Basecompelte All As Specifiedand Directed. ( Note : Cost Of Suitable Opening Wall For Fixing Exhaust Fan Is Deemed To Be Includedin Overall Rate Quoted ) . 115 Taking Down Existing Old Extg Unserviceable Lt Ug / Service Cable Of Any Description And Sizecomplete All As Specified And Directed. 116 Supply & Laying In Trenches / Laid In Floor / Duct / Drawn Through Conduitxlpe Insulated, Armoured, Heavy Duty Elecric Cable With Alluminium Conductor, 1100 Volt Grade Cross Sectional Area 25 Sqmm 4 Core. 117 Excavation In Trenches Not Exceeding 1.5 Mtrs Wide & Not Exceeding 1.5 Mtr In Depth In Soft Or Loose Soil & Getting Out Complete All As Per & Directed. 118 Returning Filling Including Spreading Levelling Watering & Well Ramming In Layers Not Exc 25 Cm 119 Removal Of Excavated Soil To A Distance Not Exc 50 M And Depositing Where Directed At A Level Not Exc 1.5 Mtr Above The Starting Point Complete All As Directed. 120 M & L For Laying Of Hdpe Double Wall Corrugated Pipes In Trench For Ug Cable Protection Conforming To Is-14930 Part-Ii With Ip-67 Having Outer Dia 50 Mm And Inner Dia Of 38 Mm Including Necessary Fittings Such As Couplers, Bends Etc Complete All As Specified And Directed. Make: Rex / Rudrax Polymers / Finolex 121 M & L For Earthing Complete With Galvanized Steel Earth Plate Electrode 60 Cm X 60 Cm X 6 Mm Thick Buried Directly In Ground Vertically ( Earth Pit Not Less Than 2.25M Deep Below Ground Level ) With Top Edge Of The Plate Not Less Than 1.50 Mtr Deep Below Normal Ground Level, Connecting To Gi Earth Wire 4Mm Dia By Means Of Bolts, Nuts, Check Nuts, And Washers Of Galvanized Iron Or Steel Including 15 Mm Dia. Medium Grade Protection Pipe For Earth Lead Complete With Charcoal And Common Salt Including Watering Arrangement With Galvanized Iron Pipe Light Grade 20 Mm Dia, Pcc Chamber, Ci Frame And Cover, Ms Funnel With Wire Mesh All As Shown In Electrical Plate No 3 Of Ssr Part I Including Excavation And Earthwork In Any Type Ofsoil / Strata And Testing On Completion. Note:- Gi Earth Wire 4 Mm Dia And 15 Mm Dia Protection Pipe Upto 7.5 Mtr From Earth Plate Is Deemed To Be Included In Rate Quoted.