Tender For Provision Of Certain Minor And Revenue Works At Bihta Under Age E / M ( Af ) Of Ge ( Af ) Bihta.; 1 Supply, Install, Fixing And Commissioning Split Type Air Conditioner With Cooling Function Eer 3.2 Of Capacity 1.5 Tr, Five Star Rated With Cordless Remote Control Unit And In Built Air Ioniser, Plasma Filter For Better Indoor Air Quality, Five Star Rated Suitable For Wall Mounted, Single Phase, 230 / 250 Volt Ac, With Inverter Technology And 100% Copper Coil Including Breaking Necessary Hole In Wall For Fixing Indoor And Outdoor Unit And Making Good The Disturbed Surfaces With Cement Mortar To Match With Existing Finishes After Commissioning, Making Necessary Connections Unplasticised Pvc Pipes Medium Duty 25 Mm Dia For Draining Out Condensed Water All As Required Including Necessary Connection Complete All As Specified And Directed.Note :- ( I ) Quoted Rates Deem To Be Included Cost Of Drain Pipe, Copper Tubing And 4 Sqmm Multi Standard Copper Cable ( All 3 Mtr Length ) , Outdoor Unit Bracket With Required Fasteners, Cutting Hole In Brick Wall Etc. ( Ii ) Installation And Commissioning To Be Done Through Oem / Itsauthorised Service Centre / Agency. 2 S&F Sheet Metal Enclosure With A Two Pin And Earth Plug And Socket Complete With One Single Pole Mcb Of 240 Volts, 20 Amps, C Series, 10 Ka, Complete All As Specified And Directed. 3 S & F Sub Main Wiring Using Approved Colour Coding ( Phase-Red, Neutral-Black, Earth-Green ) Complete With Two Single Core Frls Pvc Insulated And Unsheathed Stranded Copper Conductor Cable 4 Sqmm As Current Carrying Conductor And As Neutral Cable, Voltage Rating 1100 Volt, Isi Marked Drawn In And Including Concealed Pvc Conduit Isi Marked Of Dia Not Less Than 25 Mm And Thickness 2 Mm With Stranded Accessories Along With One Run Of Frls Pvc Green Colour Insulated, Unsheathed, Stranded Copper Conductor Of Size 4 Sqmm, Complete All As Specified And As Directed .Notes: ( A ) Two Runs Of Single Core Frls Pvc Cable With One Run Of Earth Contunity Conductor And Conduit Shall Be Measured As One Unit. ( B ) Cost Of Cutting Chases In Wall For Concealling Conduit And Making Good To Match With Existing Finish Shall Be Deemed Included In The Quoted Unit Rate. 4 Supply And Fixautomatic Copper Wound Voltage Stabilizer For Low And High Voltage Correction Equipped With Electronic Transistorised Relay, Time Relay For Two Minute Suitable For Correction On Single Phase 50 Cycles, Ac Supplyvolt Meter Indicator And Input Voltage 180 V To 300 V And Stabilized Voltage Between 220 ±5% Of Capacity 5 Kva, Complete All As Specified And Directed. Note : This Item Shall Be Fixed With Ac Catered In Respective Item Of This Schedule. 5 Excavation In Trenches Not Exc 1.5 M Wide And Not Exc 1.5 M Deep For Foundation Etc Or For Shafts, Column Footings Or For Laying Cables Etc Not Exc 10 Sqm On Plan And Getting Out In Soft / Loose Soil, Complete All As Specified And Directed. 6 Returning, Filling In Soil Including Spreading, Levelling, Watering And Well Ramming In Layers N.Exc 25 Cm Thick Complete All As Specified And Directed. 7 Removing Excavated Materials ( Soil ) Not Exc 50 M Distance And Depositing Where Directed At A Level Not Exc 1.5 M Above Starting Point, Complete All As Specified And Directed. 8 Supply And Laying Well Burnt Old Size Sub Class B Bricks As Protection To Underground Cables, Laid Dry And Flat Perpendicular To The Direction Of Cable Adjoining Each Other, Complete All As Specified And Directed. 9 M&L Fordry Andfine River Sandfree From Sharp Materialas Incushioning To Cablein Trenches For Cable Protectionincludingnecessary Punning And Consolidation As Required, Complete All As Specified And As Directed. ( Depth Of Sand Shall Be Measured After Punning ) . 10 Supply, Laying, Jointing And Testing Of Cable Xlpe Insulated, Screened, Pvc Bedded, Galvanised Steel Strip Or Wire Armoured Electric Power Cable, Heavy Duty, With Aluminium Conductor, 1100 Volts Grade, Complete All As Specified And Directed For Thefollowing Size Of Cables: - ( A ) Cross Sectional Area 240 Sqmm 3½ Core 11 ( B ) Cross Sectional Area 50 Sqmm 3½ Core 12 ( B ) Cross Sectional Area 35 Sqmm 3½ Core 13 ( B ) Cross Sectional Area 16 Sqmm 4 Core 14 S&F Gi Tubing, Light Grade, With All Fittings And Laid In Trenches / Under Roads, Drains Etc, Or Fixed To Poles / Walls With Fi Clamps, Nut, Bolts Etc And Making Good Disturbed Surfaces, Complete All As Specified And Directed For The Following Bore Of Pipes: - ( A ) 40 Mm Bore 15 ( B ) 50 Mm Bore 16 ( B ) 15 Mm Bore 17 M & L For Drilling Of Suitable Dia Horizontal Bore Holes Suitable For Insertion / Laying Of Pipe Upto 50 Mm Of Any Description Below / Under Road Surface, Floor Etc At Site Including Making Good Disturbed Surface To Match With Existing Strata After Laying Pipe Complete All As Specified And Directed. 18 Supplying, Installing, Testing & Commissioning Out Door Type Cubical Panel Board Outer Shell Made Out Of3.15 Mm Thick Ms Sheet And Inner Shell Made Out Of 2 Mm Thick Ms Sheet And Ms Angle Section 50X50x6 Mm Mounted On Pcc 1:2:4 Type B-1 Platform 60 Cm Above And 45 Cm Below The Ground Level, Frame Factory Fabricated With Front Openable Double Door System And Cable Alloy ( Each Door Hinged With Body At 3 Places With Hinges Welded To Body And Door ) Lockable / Open Able By Keys Having Chromium Plated 19 Mm Dia Fancy Lock, “U” Type Gasket Shall Be Used To Make The Outer Shell Completely Vermin Proof Suitable For 3 Phase 4 Wire 415 Volt, 50 Hz, Tested At Factory Approved From Cpri For 35 Mva Rupturing Capacity At 415 Volts Factory Fabricated Having Modern Fabrication And Testing Process, Complete All As Specified And Directed And Comprising Of The Following: - ( A ) Tpn Aluminium Bus Bar 400 Amps Insulated With Colour Coded Heat Shrinkable Sleeve And Shall Be Mounted On Suitable Size “F” Class Insulators Not Less Than 1.0 Mtr Long. ( B ) Incoming Mccb200 Amps 4 Pole 415 Volts Ac, Icu=100%Ics, Rupturing Capacity 25 Ka, Confirming To Is / Iec 60947-2 - 01 No. ( C ) Outgoing Mccb 100 Amps 3 Pole 415 Volts Ac, Icu=100%Ics, Having Microprocessor Based Release For Over Current, Short Circuit & Earth Fault With Display And Fault Discrimination Rupturing Capacity 25 Ka, Confirming To Is / Iec 60947-2 - 02 Nos. ( D ) -Ditto- But Mccb 63 Amp - 1 No. ( E ) Mcb Tpn32 Amps 16 Ka - 02 Nos . ( H ) Indicator Lamps Led Type Ryb With Holder - 01 Set Of Three. ( J ) Ct Coils Of Suitable Ratio - 01 Set. 19 Supply, Install, Testing And Commissioning Of Out Door Type Cubical Feeder Pillarbox, Tpn Of Size 600X600x300mm Aluminium Bus Bar 200 Amps, Outer Shell Made Out Of 3.15 Mm Thick Ms Sheet Inner Shell Made Out Of 2.00Mm Thick Ms Sheet And Ms Angle Section 40X40x6 Mm On Pcc 1:2:4 Type B-1 Platform 60Cm Above The Ground Level And 30 Cm Below The Ground Level, Frame Factory Fabricated With Front And Back Openable Double Door System Complete Suitable For 3 Phase 4 Wire 415 Volt, 50 Hz With Ip 54. The Bus Bar Shall Be Provide With Sufficient Holes For Distribution Of Lt Supply To 8 Houses Single Phase And Making Necessary Distributions With The Help Of Thimbles Etc, Complete All As Specified And As Directed. 20 M & L For Earthing Complete With Galvanized Steel Earth Plate Electrode 60Cm X 60Cm X 6 Mm Thick, Buried Directly In Ground ( Earth Pit Not Less Than 2.25 Mtr Deep Below Ground Level ) With Top Edge Of The Plate Not Less Than 1.5 Meters Below Normal Ground Level, Connected To Galvanised Iron Strip 25X4 Mmas Earthing Leadby Means Of Bolts, Nuts, Check-Nuts, And Washers Of Galvanised Iron Or Steelincluding Excavation And Earth Work, Gi Pipe Medium Grade 32 Mm Bore For Protection Of Gi Strip From Earth Electrodeto Test Point / Machinery / Equipment, Supplying And Laying Charcoal Dust, Common Salt, Pcc ( 1:2:4 ) Type B1 Using 20 Mm Graded Crushed Stone Agregrate Chamber Andrcc Cover 54 Cmx54cm X50 Mm Thick ( 1:2:4 ) Type B-1 Using 20 Mm Graded Crushed Stone Aggregates, Reinforced With 8 Mm Dia Tmt Bars @ 75Mm C / C Both Ways With Mild Steel Handle 12 Mm Dia, Using Round Bar, Pgi Funnel With Wire Mesh, 20 Mm Dia Gi Pipe Light Grade For Watering All As Shown In Electrical Plate No-3 Of Ssr Part-1 And Testing On Completion Includingd Taking Out The Oldunserviceable Earthing Complete All As Specified And Directed. Note - Cost Of Gi Strip And Gi Protection Pipe Up To A Distance 7.5 M Shall Be Included In Quated Rate Of Above. 21 S & F For 4 Pole Mccb 63 To 100 Amp, 50 Hz, 415 V With Rupturing Capacity 16 Ka, Ics = 100% Of Icu, Adjustable Type, Complete All As Specified And Directed. 22 S&F 40 Watt Led Decorative Post Top Gate Light For 360 Degree Indirect Light With Ip 65 Protection And Complete All As Directed. 23 M&L For Fixing Cable Junction Box Lt 3 Phase Type Having Ip 66 / 69 Weather Proof For Outdoor Installation Made Of Plastic Material Of Size 350X250x138 Mm Withopaque Cover, Conical Cable Gland Aluminium Lugs, Protection Class Ip 65, 04 Nos Aluminium Bus Bar Of Size 25X4 Mm For Three Phase And Neutral Including 01 No Mcb Sp 6 Amps For Controlling Street Light And2 Nos Ms Clamp Of Size 30X5 Mm Complete With Nut, Bolt And Washers For Mounting The Junction Box On Street Light Pole Complete And All As Specified And Directed By Engineer-In-Charge. Make-Sintex Product Code-Gsmb 3425 Or Equivalent Make And Model As Approved By The Ge. 24 S&F Pvc Insulated And Pvc Sheathed 4.00 Sqmm Twin Core Round Fr Copper Conductor Industrial Cable, 1100 Volt Grade, Conforming To Is 694 And Making Necessary Connections From Junction Box To Street Light By Using Suitable Size Of Aluminium Thimbles / Terminal Etc And Testing, Complete All As Specified And As Directed. 25 Supply And Fix Gate Light Controller Nature Switch Of 3 Phase 8 Kw ( Swadeep-66-8Kw 3P ) With Contactor, Incoming Mcb & Outgoing Mcb Rating Of 32 Amps & Main Load Circuit Wiring ( Copper ) Of Min Size 10 Sqmm. The Automatic Street Light Control Switch Using Infrared Sensor Based Nature Switch For Automatic Switching Of Street Lights. Nature Switch Operation Should Be Based On Natural Light Lux Level. Required Illuminance Level For Switching On Is =30 Lux And For Switching Off =10 Lux.The Sensor Should Also Have Part Night Operation Facility Of Minimum 4 Hrs To Max 12 Hrs. The Sensor Alongwith Suitable Power Contactor ( S ) And Incoming And Outgoing Mcbs Should Be Enclosed In A Pole / Wall Mountable Rust Proof, Electric Shock Proof, Terminate Proof And Fr Grade Ip66 Protection Class 2 Enclosure Made Of Thermoplastic Polycorbonate And Protected Against Weather Influences. The Circuit Should Have Provision For Manual Operation ( I.E. Sensor By-Pass Option ) . Make Of Panel Consisting Of ( I ) Nature Switch - Healer ( Ii ) Contactors - Bch ( Iii ) Mcbs - Hager ( Iv ) Enclosure - Hensel, ( V ) Circuit Wiring - Polycab. ( Vi ) Contactor Should Confirm To Iec-60947-4-1 / Is-13947-4-1 And Mcbs Should Conform To Iec-60898 / Is-8828 Or Another Make As Approved By The Ge. 26 Taking Down Carefully Copper / Aluminum Concealed Flame Proof Point Wiring ( Light / Fan / Socket / Power ) Complete Including Fittings And Fixtures Such As Switches, Ceiling Roses, Pendents, Regulators, Sockets, Light Fittings, Sunk Box, Steel Terminal Box, Laminated Sheet With All Accessories Etc. And Making Good Finish Of The Disturbed Surfaces Of Walls In Line With Existing Wall Etc Complete All As Specified And As Directed. 27 Material And Labour For 304 Grade Stainless Steel Sheet Having Thickness 3Mm For Replacing Laminated Sheet Cover Wherever Required Complete With Nut, Bolt And Washers And Complete All As Directed And Specified By Engineer In Charge. 28 Material & Labour For Fixing Spot Light Bracketmade Out Of Gi Pipe Light Grade 40Mm Bore Approx Length Not Less Than 190 Cm At A Distance Of 1 Foot From The Wall ( For Fixing Of Spot Lights ) Including New Clamps On Both Ends Of The Wall, Made Out Of Ms Flat Of Size 30X5mm Thick Including Cutting, Welding, Drilling Holes, Nut Bolts, Washer, Etc Including Applying Two Coats Of Aluminium Paint Over One Coat Of Red Oxide Primer On Ms Work And Complete All Asspecified And Directed By Engineer In Charge. 29 S&F Led Spike Light ( Spot Light ) Environmental Friendly, New Generation, Energy Saving, Decorative Type Having Ip66 Protection Led Spike Light Using Cob Led As Light Source And Complete All As Directed. Make : Havells Cat Part No-Lycussps15wled730psymbotg Or Equivalent. 30 M&L For Concealed Point Wiring Complete With Pvc Frls Insulated And Unsheathed Cable 2.5 Sqmm ( Nominal Area ) Multi Stranded Copper Conductor Single Core Conforming To Is : 694 Medium Duty Concealed Stove Enamelled Steel Conduit Conformingto Is : 9537 ( Part-3 ) And Isi Marked Not Less Than 20 Mm Dia With Concealed In Wall Pressed Steel Terminal Boxes Not Less Than 1.2 Mm Thick Of Required Size ( Factory Made ) Including Painting Terminal Boxes Inside And Outside With Two Coats Of Synthetic Enamel Paint Over One Coat Of Red Oxide Primer And Withtop Cover 3 Mm Thick Of Plastic Laminated Sheets Of Required Colour Complete With All Accessoriesand Including Pvc Frls Insulated And Unsheathed Cable 2.5 Sqmm ( Nominal Area ) Multi Stranded Copper Conductor Single Core Conforming To Is: 694 Of Green Colour As Earth Wire To Common Earth And Connected To Earth Dolly Drawn In Same Concealed Conduit Complete For The Following: - ( A ) One Light / Fan / Exhaust Fan / Power Socket Outlet Point Controlled By One Switch 31 S & F Flame Proof Switch Rotary Type With Termination Box In Lm 6 / 16A Single Pole 250 Volt All As Specified And Directed. Make-Shyaam / Sudhir Or Equivalent. 32 Supply And Fixing Stainless Steel Flexible Wire Conduit Having Cross Sectional Area 30Sqmm For Enclosing Open Wire Whereever Required And Complete All As Specified And Directed By Engineer In Charge. 33 Supply And Fixing Stainless Steel Saddle Suitable For Clamping Purpose Of Above Mentioned Stainless Steel Flexible Conduit And Complete All As Specified And Directed By Engineer In Charge. 34 S & F Led Bollard Made Up Of Extruded Aluminium With Pc Diffuser With Fitting On Gi Pipepipe 12 Watt With Ordering Code Surya Sle Bl 12W-Blk800 Or Equivalent As Approved By The Ge, Complete All As Specified And Directed 35 S&F Sheet Metal Enclosure 2 Way Single Door Ip-43 With Complete Including One Single Pole & Neutral Mcb 6A 10 Ka C Series, Fixed Flush Into Walls And Making Good Disturbed Surfaces, Complete All As Specified And Directed. 36 Supplying And Fixing 1100 Volts Grade Heavy Duty Cable Pvc Insulated Aluminium Conductor, Served With Inner Sheathing Of Pvc Tape And Overall Pvc Sheathed In Service Connections 4 Sqmm Multi Stranded, Complete All As Specified And Directed. 37 M&L For Conducting Of Energy Audit Of Complete Electrical System Of All Assets All As Specified And Directed By Engr-In-Charge.Notes :- ( I ) Energy Audit Company Must Be Registered With Bee. ( Ii ) The Audit Must Be As Per Iso 50002:2014. ( Iii ) The Transformer / Vcb / Motor / Pump Set / Dg / Stabilizer / Isolation Transformer / Cables / Oh Conductors / Lt / Ht Panels Or Any Other Devices / Panels / Equipment Shall Be Analysed / Audited Catering All The Pump Houses And Power Houses. ( Iv ) All The Machine / Devices / Tools / Equipment Required The Rates Are Included In Schedule Rates. ( V ) Energy Audit Reports Must Contain Energy Consumption / Balance And Energy Efficiency And Shall Be Submitted To Ge ( Af ) Bihta 38 Supply And Install Air Conditioner, Vertical Pack Type Units Indoor / Outdoor Complete With Cordless Remote Control Unit, Twin Rotary Compressor, Single Phase Units 220V - 240V, 50 Hz Of Capacity 2.5 Tr, With Noise Supression Technology And Time Temperature Display, Minimum 3 Star Rated With All Inbuilt And Connected Accessories Provided By Company In Box, With Inverter Technology And 100% Copper Coil, Complete All As Specified And Directed. 39 S & F Sub Main Wiring Using Approved Colour Coding ( Phase-Red, Neutral-Black, Earth-Green ) Complete With Two Single Core Frls Pvc Insulated And Unsheathed Stranded Copper Conductor Cable 6 Sqmm As Current Carrying Conductor And As Neutral Cable, Voltage Rating 1100 Volt, Isi Marked Drawn In And Including Concealed Pvc Conduit Isi Marked Of Dia Not Less Than 25 Mm And Thickness 2 Mm With Stranded Accessories Along With One Run Of Frls Pvc Green Colour Insulated, Unsheathed, Stranded Copper Conductor Of Size 6 Sqmm, Complete All As Specified And As Directed .Notes: ( A ) Two Runs Of Single Core Frls Pvc Cable With One Run Of Earth Contunity Conductor And Conduit Shall Be Measured As One Unit. ( B ) Cost Of Cutting Chases In Wall For Concealling Conduit And Making Good To Match With Existing Finish Shall Be Deemed Included In The Quoted Unit Rate. 40 M & L For Suction And Discharge Copper Tubing Of Appropriate Dia And Thickness Suitable For Vertical Pack Type Ac Of Capacity 2.5 Tr With Black Insulating Material Fixed On It, Complete All As Specified And Directed.
Tender Notice
Key Value
28 Lakhs
28 Lakhs
28 Lakhs