Tender For Special Repair To Buildings No P-73 (Urc Bldg) At Ota Gaya; 1 Excavating in trenches, n exc 1.5m wide & n exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan & getting out in hard/dense soil 2 Excavating in trenches, n exc 1.5m wide & exc 1.5m but n exc 3.0m in depth; for fdn etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan & getting out in hard/dense soil 3 Removing excavated soil n exc. 50m & depositing where directed at a level n exc. 1.5 m above the starting point 4 Returning, filling in, incl spreading, levelling, watering & well ramming in layers n. exc 25 cm in soil. 5 M & L PCC in foundations, filling and mass-concrete type D2 (1:4:8) using 40 mm graded stone aggregate 6 Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete. 7 Demolition of Concrete of any description and in any position not otherwise specifically provided for complete. 8 Demolition ofreinforced cement Concrete of any description and in any position not otherwise specifically provided for complete. 9 Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. 10 M & L brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:4 11 M & L for Brickwork with fly ash bricks straight or curved on plan to any radius in half brick thick walls built in CM (1:4) 12 M & L RCC M-25 design mix using 20 mm graded aggregate in beams, cantilevers, lintels over 1.5 m span 13 M & L RCC M-25 design mix using 20 mm graded aggregate in Foundations, incl rafts, footings, foundation beams; plinth beams; bases for columns and mass concrete 14 M & L RCC M-25 design mix using 20 mm graded aggregate in Columns, pillars, piers, posts and struts 15 M&L RCC M-25 design mix using 20 mm graded aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like 16 Form work to sides of concrete foundations, footings, bases of columns,sides & soffits of foundation & plinth beams and similar work Rough finished surfaces of concrete flat 17 Form work to sides of pillars, posts, struts, piers,columns, and stanchions Rough finished surfaces of concrete Square, rectangular or polygonal 18 Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings & similar work; not exc. 200mm thick (Horizontal or sloping) Rough finished surfaces of concrete flat 19 M&L Mild steel TMT bars 10mm dia & over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality 20 -ditto- all as per Item No 19 Above but 6 to 8 mm dia as in spacers and binder 21 S & F of 4 mm thick HPSC (High Pressure steam cured) pre-primed textured designer board, water resistant, be placed in the grid system duly suspended with 2 mm dia GI bar hangers fixed with steel dash through fasteners from purlins of the roof complete all as specified. 22 M & L for anodised aluminium snap grid frame work for false ceiling all as specified and as directed. 23 M & L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and no pigments including 15mm thick sceed bed in CM 1:6 Complete. 24 S & F of Framed work as in including moulding, cuttings, and made to shape as directed, such as grills, gratings, etc with ends of bars shouldered and/or riveted or welded, or forged into spikes, framed guard bars and similar work conforming to Fe.290. Gde-E-165 complete all as directed & specified. 25 M&L Rendering 15mm thick in two coat on stone masonry surfaces or surface other than fair face of brickwork in CM (1:4) finished even & smooth (without using extra cement) and applying WPC on second coat @ 3% by wight of cement or manufacturere instruction 26 M&L Rendering 10mm thick on stone masonry surfaces or surface fair face of brickwork in CM (1:6) finished even & smooth (without using extra cement) 27 M & L for Hard core of Broken bricks gauge n exc. 63mm, deposited, spread & levelled in layers n exc. 15 cm thick, watered & rammed to a true surface 28 M & L 75 mm thick PCC type C-2, (1:3:6) using 40mm graded stone aggregate as inpath and concrete surface finished even and smooth without using extra cement. 29 M & L 25mm thick PCC type B-1, (1:2:4) using 20mm graded stone aggregate as in levelling course for tiles complete. 30 M & L for virified ceramic light shade double charged tiles 7.5 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and incl 15mm thick screed bed or bedding layer with CM 1:4 complete. 31 M & L for virified ceramic light shade double charged tiles 7.5 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in skitting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and incl 10mm thickrendering bed or bedding layer with CM 1:4 complete. 32 M&L Rendering 10mm thick on fair faces of brick work or concrete surfaces in CM (1:3) in ceiling complete. 33 M & L for two coats of exterior weather proof paint white or tinted on walls, fascia of roof or chajjas, col facia at any height on old painted surfaces of brick, stone, concrete, asbestos cement or plastered or unplastered surfaces of bldg all as specified & directed.Make : Asian Paints(Apex dust proof) or equivalent paint. 34 M & L for preparation of new plastered surfaces and applying two coat of oil bound distemper over a coat of primer including 1mm thick putty complete all as specified and directed by Engr-in-Charge. 35 M & L for preparation of old plastered surfaces and applying two coat of oil bound distemper over a coat of primer including 1mm thick putty complete all as specified and directed by Engr-in-Charge. 36 M & L 75mm thick PCC type C-1, (1:3:6) using 40mm graded stone aggregate finished even & smooth without using extra cement as in plinth protection/Path 37 Taking down chowkhats or frames exceeding 1.50 sqm and not exceeding 4 sqm each but with shutters (without taking off shutters from the frame) complete all as specified. 38 S & F ofPressed steel frames 105 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed 39 S & F 30 mm Flush shuteers solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. 40 S & F Framed work as in doors or gates of angle or other section with gusset plates, rails,braces,etc.,complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing completeconforming to Fe.290.Gde-E-165 41 Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes,channels, plates etc., including welding, grinding,buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement. 42 M&L two coat of synthetic enamel paint overnew woodensurfaces of any description not otherwise described over 10cm in width or grith over one coat of pink primerincluding preparation of surfaces complete. 43 M&L two coat of synthetic enamel paint overold woodensurfaces of any description not otherwise described over 10cm in width or grith over one coat of pink primerincluding preparation of surfaces complete. 44 M&L two coat of syntetic enamel paint overnewsteel surface of any description over 10cm in width or grithnot otherwise describedover one coat red oxide primerincluding preparation of surfaces complete. 45 S & F for Powder coated aluminium frame for doors,windows, ventilators with one or morerebates including joining cleat for fixing etc. complete all as specified and directed. 46 S & F Aluminium handle cast type anodized 150mm size 47 S & F Aluminium, anodized, barrel tower bolts of extruded section 200mm long 48 S&F Butt Hinge extruded aluminum alloy with galvanized MS Hinge Pin anodised and fixed 125mm long, type B-21 complete. 49 S & F Aluminum alloy, anodized, sliding door bolt with hasp & staple (Bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy size 300mm long. 50 M&L for PCC 1:2:4, type B-1 using 20 mm graded stone aggregate as in coping, benching, bed block, lintel band, plinth courses, drains and channels etc including necessary form work complete 51 Taking down existing old Extg unserviceable LT UG/ service cable of any description and sizecomplete all as specified and directed. 52 Supply and laying & testing and commisioning LT underground cable 1100 volts grade, XLPEinsulated and PVC sheathed heavy duty armoured with multi staranded aluminium conductor laid in pipes, trenches/ ducts, on poles etc of sizecomplete all as specified and directed 53 (a) 3.5 core x 120 Sqmm 54 (b) 3.5 core x 35 Sqmm 55 Removing of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. 56 Burnt bricks sub class B laid flat dry across the cable for cable protection all as specified and directed. 57 Sand cushioning to UG cable 8cm thick before laying the cable and 15cm above the cable, stretching and testing of cable complete all as specified and directed. Note: (i) Consolidated / Punned sand shall be considered for purpose of payment (ii) Sand shall be same as specified for plastering work. 58 S & F outdoor type LT Feeder piller box of size 600x600x300mm deep, 415 volts, 3 phase, 4 wire 50 Hz having 04 Nos colour coded aluminium bus bar of capacity 600 Amps mounted on porcelain/ hygroscopic insulators with suitable number of holes for making connections of cables, made out of 3.15mm thick sheet steel CRCA and mounted on frame of suitable size made out of angle iron 50x50x6mm with 4 Nos legs embedded in PCC foundation 300mm below ground level and 300mm above ground level, duly painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, dust and vermin proof, front door with locking arrangement and two earth points by side of the box, cubical type with cable glands, sockets etc and with provision of cable entry from bottom, including painting steel frame complete all as specified. 59 M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth strip 25x4mm by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR Part I including excavation and earthwork in any type ofsoil/strata and testing on completion. Note:- GI earth strip 25x4 mm and 40 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted. 60 Taking down copper/aluminium point wiring (light, fan, bell, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendent, regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc complete all as specified and directed at site. 61 Taking down ceiling fan/ exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan bladesand deposit to MES store yard of AGE E/M Gaya complete all as specified and directed. 62 M&L for point wiring with 1.5 Sq mm single core PVC insulated unsheathed copper FRLS multi stranded conductor cable in and including concealed PVC conduit of size 20/25mm ISI marked inclusive oftees, bend, elbows etc upto and including sunk in anodized pressed steel box for housing switch socket etc withwhite laminated 3 mm thick hylum sheet cover ISI marked of suitable size complete including PVC insulated multi stranded copper conductor 1.5Sq mm FRLS cable as earth wire to common earth dolly for connection to ceiling rose to earth terminalincluding cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed by Engr-in-charge for following :- 63 (a) One light point controlled by one, one way switch 5 Amps 64 (b) One fan point/ exhaust fan point controlled by one, one way switch 5 Amps. 65 (c) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. 66 (d) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board. 67 Description all as per item No.3 here in before but using 2.5 sqmm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly. 68 Description all as per item No.3 here in before but using 4.0 sqmm single core copper conductor FRLSH cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket combination point including necessary running of4.0 sqmm FRLSH PVC insulated copper conductor cable as earth continuity conductor along with wiring and connecting to the common eath dolly. (for AC Point) 69 S&F switch piano type single pole 5 amp, 230 Volts complete all as specified and directed. 70 S&F switch piano type single pole 15 amp, 230 Volts complete all as specified and directed. 71 S&F socket outlet 2-in-1, 3 pin, 5 amp, 230 Volts complete all as specified and directed. 72 S&F socket outlet 2-in-1, 3 pin, 5 and 15 amp flush type, 230 Volts complete all as specified. 73 S&F ceiling rose, surface bakelite with 3 terminals, ISImarked for batten fitting complete all as specified 74 S&F stepped type electronic fan regulator flush type complete all as specified and directed. 75 S&F lamp holder, PVC / Polycarbonate type with back plate suitable for batten/ slanting fittings complete all as specified and directed. 76 S&F metal clad box suitable for 230 volt 50 Hz AC supplywith 16 Amp Socket, MCB SP 20/32 Amps and 16 Amp plug top including removal of old unserviceable one complete all as specified and as directed. 77 M & L for sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etcone run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit 78 M & L for sheet metal enclosure MCCB DBs, Triple pole & neutral 4 way with 200 Amp rated bus bar double door suitable for 01 No incoming MCCB of 125 Amp capacity and 12 Nosout going MCB SP complete all as specified and directed. Note: MCCB & MCBs are measured and paid in separate items. 79 S & F sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. 80 S & F for MCB Single pole and neutral rated capacity 32 Amps, 240 Volts breaking capacity 10 KA, C curve complete all as specified and as directed. 81 S & Ffor MCB Single pole rated capacity 6 to 32 Amps, 240 Volts breaking capacity 10 KA, C curve complete all as specified and as directed. 82 S & F MCCB 4 pole, 125 Amps with breaking capacity 16 KA, 415 volts complete all as specified and directed. 83 S & F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep, min air delivery 210 CFM with service value 6.00 BEE five star rated with brushless direct current motor (BLDC) including electrical connections from ceiling rose to fan terminal complete all as specified and directed. 84 Labour hanging only ceiling fan obtained from item No. 2 above and connecting up including provision of 3 core PVC insulated PVC sheathed multistranded copper conductor cable of size 23/ 0.193 from ceiling rose to fan terminal and M & L for painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed. 85 S & F for wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouputboxtype fitting, 230 volts and intregrated electronic driver connector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired andnecessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. 86 Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. 87 S & F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete necessary mounting arrangements and provision of 0.75 Sqmm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by Engineer- in-charge. 88 S & F exhaust fan, steel body AC single Phase 230V of size 300mm sweep with, blades, and frame and louvers with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan for connection complete all as specified and directed. 89 M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including excavation and earthwork in any type ofsoil/strata and testing on completion. Note:- GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted.

Tender Notice

45317672

Military Engineer Services

Indian


gaya

Bihar

October 03, 2024

Key Value

Ref. Documents

Ref. Documents

Ref. Documents

To Download Tender Document Click on the below link

Tender For Special Repair To Buildings No P-73 (Urc Bldg) At Ota Gaya; 1 Excavating in trenches, n exc 1.5m wide & n exc 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan & getting out in hard/dense soil 2 Excavating in trenches, n exc 1.5m wide & exc 1.5m but n exc 3.0m in depth; for fdn etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan & getting out in hard/dense soil 3 Removing excavated soil n exc. 50m & depositing where directed at a level n exc. 1.5 m above the starting point 4 Returning, filling in, incl spreading, levelling, watering & well ramming in layers n. exc 25 cm in soil. 5 M & L PCC in foundations, filling and mass-concrete type D2 (1:4:8) using 40 mm graded stone aggregate 6 Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete. 7 Demolition of Concrete of any description and in any position not otherwise specifically provided for complete. 8 Demolition ofreinforced cement Concrete of any description and in any position not otherwise specifically provided for complete. 9 Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. 10 M & L brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:4 11 M & L for Brickwork with fly ash bricks straight or curved on plan to any radius in half brick thick walls built in CM (1:4) 12 M & L RCC M-25 design mix using 20 mm graded aggregate in beams, cantilevers, lintels over 1.5 m span 13 M & L RCC M-25 design mix using 20 mm graded aggregate in Foundations, incl rafts, footings, foundation beams; plinth beams; bases for columns and mass concrete 14 M & L RCC M-25 design mix using 20 mm graded aggregate in Columns, pillars, piers, posts and struts 15 M&L RCC M-25 design mix using 20 mm graded aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like 16 Form work to sides of concrete foundations, footings, bases of columns,sides & soffits of foundation & plinth beams and similar work Rough finished surfaces of concrete flat 17 Form work to sides of pillars, posts, struts, piers,columns, and stanchions Rough finished surfaces of concrete Square, rectangular or polygonal 18 Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings & similar work; not exc. 200mm thick (Horizontal or sloping) Rough finished surfaces of concrete flat 19 M&L Mild steel TMT bars 10mm dia & over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality 20 -ditto- all as per Item No 19 Above but 6 to 8 mm dia as in spacers and binder 21 S & F of 4 mm thick HPSC (High Pressure steam cured) pre-primed textured designer board, water resistant, be placed in the grid system duly suspended with 2 mm dia GI bar hangers fixed with steel dash through fasteners from purlins of the roof complete all as specified. 22 M & L for anodised aluminium snap grid frame work for false ceiling all as specified and as directed. 23 M & L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and no pigments including 15mm thick sceed bed in CM 1:6 Complete. 24 S & F of Framed work as in including moulding, cuttings, and made to shape as directed, such as grills, gratings, etc with ends of bars shouldered and/or riveted or welded, or forged into spikes, framed guard bars and similar work conforming to Fe.290. Gde-E-165 complete all as directed & specified. 25 M&L Rendering 15mm thick in two coat on stone masonry surfaces or surface other than fair face of brickwork in CM (1:4) finished even & smooth (without using extra cement) and applying WPC on second coat @ 3% by wight of cement or manufacturere instruction 26 M&L Rendering 10mm thick on stone masonry surfaces or surface fair face of brickwork in CM (1:6) finished even & smooth (without using extra cement) 27 M & L for Hard core of Broken bricks gauge n exc. 63mm, deposited, spread & levelled in layers n exc. 15 cm thick, watered & rammed to a true surface 28 M & L 75 mm thick PCC type C-2, (1:3:6) using 40mm graded stone aggregate as inpath and concrete surface finished even and smooth without using extra cement. 29 M & L 25mm thick PCC type B-1, (1:2:4) using 20mm graded stone aggregate as in levelling course for tiles complete. 30 M & L for virified ceramic light shade double charged tiles 7.5 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and incl 15mm thick screed bed or bedding layer with CM 1:4 complete. 31 M & L for virified ceramic light shade double charged tiles 7.5 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in skitting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and incl 10mm thickrendering bed or bedding layer with CM 1:4 complete. 32 M&L Rendering 10mm thick on fair faces of brick work or concrete surfaces in CM (1:3) in ceiling complete. 33 M & L for two coats of exterior weather proof paint white or tinted on walls, fascia of roof or chajjas, col facia at any height on old painted surfaces of brick, stone, concrete, asbestos cement or plastered or unplastered surfaces of bldg all as specified & directed.Make : Asian Paints(Apex dust proof) or equivalent paint. 34 M & L for preparation of new plastered surfaces and applying two coat of oil bound distemper over a coat of primer including 1mm thick putty complete all as specified and directed by Engr-in-Charge. 35 M & L for preparation of old plastered surfaces and applying two coat of oil bound distemper over a coat of primer including 1mm thick putty complete all as specified and directed by Engr-in-Charge. 36 M & L 75mm thick PCC type C-1, (1:3:6) using 40mm graded stone aggregate finished even & smooth without using extra cement as in plinth protection/Path 37 Taking down chowkhats or frames exceeding 1.50 sqm and not exceeding 4 sqm each but with shutters (without taking off shutters from the frame) complete all as specified. 38 S & F ofPressed steel frames 105 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed 39 S & F 30 mm Flush shuteers solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. 40 S & F Framed work as in doors or gates of angle or other section with gusset plates, rails,braces,etc.,complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing completeconforming to Fe.290.Gde-E-165 41 Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes,channels, plates etc., including welding, grinding,buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement. 42 M&L two coat of synthetic enamel paint overnew woodensurfaces of any description not otherwise described over 10cm in width or grith over one coat of pink primerincluding preparation of surfaces complete. 43 M&L two coat of synthetic enamel paint overold woodensurfaces of any description not otherwise described over 10cm in width or grith over one coat of pink primerincluding preparation of surfaces complete. 44 M&L two coat of syntetic enamel paint overnewsteel surface of any description over 10cm in width or grithnot otherwise describedover one coat red oxide primerincluding preparation of surfaces complete. 45 S & F for Powder coated aluminium frame for doors,windows, ventilators with one or morerebates including joining cleat for fixing etc. complete all as specified and directed. 46 S & F Aluminium handle cast type anodized 150mm size 47 S & F Aluminium, anodized, barrel tower bolts of extruded section 200mm long 48 S&F Butt Hinge extruded aluminum alloy with galvanized MS Hinge Pin anodised and fixed 125mm long, type B-21 complete. 49 S & F Aluminum alloy, anodized, sliding door bolt with hasp & staple (Bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy size 300mm long. 50 M&L for PCC 1:2:4, type B-1 using 20 mm graded stone aggregate as in coping, benching, bed block, lintel band, plinth courses, drains and channels etc including necessary form work complete 51 Taking down existing old Extg unserviceable LT UG/ service cable of any description and sizecomplete all as specified and directed. 52 Supply and laying & testing and commisioning LT underground cable 1100 volts grade, XLPEinsulated and PVC sheathed heavy duty armoured with multi staranded aluminium conductor laid in pipes, trenches/ ducts, on poles etc of sizecomplete all as specified and directed 53 (a) 3.5 core x 120 Sqmm 54 (b) 3.5 core x 35 Sqmm 55 Removing of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. 56 Burnt bricks sub class B laid flat dry across the cable for cable protection all as specified and directed. 57 Sand cushioning to UG cable 8cm thick before laying the cable and 15cm above the cable, stretching and testing of cable complete all as specified and directed. Note: (i) Consolidated / Punned sand shall be considered for purpose of payment (ii) Sand shall be same as specified for plastering work. 58 S & F outdoor type LT Feeder piller box of size 600x600x300mm deep, 415 volts, 3 phase, 4 wire 50 Hz having 04 Nos colour coded aluminium bus bar of capacity 600 Amps mounted on porcelain/ hygroscopic insulators with suitable number of holes for making connections of cables, made out of 3.15mm thick sheet steel CRCA and mounted on frame of suitable size made out of angle iron 50x50x6mm with 4 Nos legs embedded in PCC foundation 300mm below ground level and 300mm above ground level, duly painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer, dust and vermin proof, front door with locking arrangement and two earth points by side of the box, cubical type with cable glands, sockets etc and with provision of cable entry from bottom, including painting steel frame complete all as specified. 59 M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth strip 25x4mm by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR Part I including excavation and earthwork in any type ofsoil/strata and testing on completion. Note:- GI earth strip 25x4 mm and 40 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted. 60 Taking down copper/aluminium point wiring (light, fan, bell, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendent, regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc complete all as specified and directed at site. 61 Taking down ceiling fan/ exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan bladesand deposit to MES store yard of AGE E/M Gaya complete all as specified and directed. 62 M&L for point wiring with 1.5 Sq mm single core PVC insulated unsheathed copper FRLS multi stranded conductor cable in and including concealed PVC conduit of size 20/25mm ISI marked inclusive oftees, bend, elbows etc upto and including sunk in anodized pressed steel box for housing switch socket etc withwhite laminated 3 mm thick hylum sheet cover ISI marked of suitable size complete including PVC insulated multi stranded copper conductor 1.5Sq mm FRLS cable as earth wire to common earth dolly for connection to ceiling rose to earth terminalincluding cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed by Engr-in-charge for following :- 63 (a) One light point controlled by one, one way switch 5 Amps 64 (b) One fan point/ exhaust fan point controlled by one, one way switch 5 Amps. 65 (c) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. 66 (d) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board. 67 Description all as per item No.3 here in before but using 2.5 sqmm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly. 68 Description all as per item No.3 here in before but using 4.0 sqmm single core copper conductor FRLSH cable of multistranded PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket combination point including necessary running of4.0 sqmm FRLSH PVC insulated copper conductor cable as earth continuity conductor along with wiring and connecting to the common eath dolly. (for AC Point) 69 S&F switch piano type single pole 5 amp, 230 Volts complete all as specified and directed. 70 S&F switch piano type single pole 15 amp, 230 Volts complete all as specified and directed. 71 S&F socket outlet 2-in-1, 3 pin, 5 amp, 230 Volts complete all as specified and directed. 72 S&F socket outlet 2-in-1, 3 pin, 5 and 15 amp flush type, 230 Volts complete all as specified. 73 S&F ceiling rose, surface bakelite with 3 terminals, ISImarked for batten fitting complete all as specified 74 S&F stepped type electronic fan regulator flush type complete all as specified and directed. 75 S&F lamp holder, PVC / Polycarbonate type with back plate suitable for batten/ slanting fittings complete all as specified and directed. 76 S&F metal clad box suitable for 230 volt 50 Hz AC supplywith 16 Amp Socket, MCB SP 20/32 Amps and 16 Amp plug top including removal of old unserviceable one complete all as specified and as directed. 77 M & L for sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etcone run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit 78 M & L for sheet metal enclosure MCCB DBs, Triple pole & neutral 4 way with 200 Amp rated bus bar double door suitable for 01 No incoming MCCB of 125 Amp capacity and 12 Nosout going MCB SP complete all as specified and directed. Note: MCCB & MCBs are measured and paid in separate items. 79 S & F sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. 80 S & F for MCB Single pole and neutral rated capacity 32 Amps, 240 Volts breaking capacity 10 KA, C curve complete all as specified and as directed. 81 S & Ffor MCB Single pole rated capacity 6 to 32 Amps, 240 Volts breaking capacity 10 KA, C curve complete all as specified and as directed. 82 S & F MCCB 4 pole, 125 Amps with breaking capacity 16 KA, 415 volts complete all as specified and directed. 83 S & F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep, min air delivery 210 CFM with service value 6.00 BEE five star rated with brushless direct current motor (BLDC) including electrical connections from ceiling rose to fan terminal complete all as specified and directed. 84 Labour hanging only ceiling fan obtained from item No. 2 above and connecting up including provision of 3 core PVC insulated PVC sheathed multistranded copper conductor cable of size 23/ 0.193 from ceiling rose to fan terminal and M & L for painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed. 85 S & F for wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouputboxtype fitting, 230 volts and intregrated electronic driver connector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired andnecessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. 86 Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. 87 S & F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete necessary mounting arrangements and provision of 0.75 Sqmm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by Engineer- in-charge. 88 S & F exhaust fan, steel body AC single Phase 230V of size 300mm sweep with, blades, and frame and louvers with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan for connection complete all as specified and directed. 89 M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including excavation and earthwork in any type ofsoil/strata and testing on completion. Note:- GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted.