Supply Of Machines And Equipments For Civil Engineering Lab-1 Direct reading transit theodolite 2 with tripod 2 Dumpy level with tripod 3 Prismatic compass with tripod 4 Cross Staff 5 Optical Square 6 Ranging Rod (Steel) 4m 7 Ranging Rod (Steel) 3m 8 Leveling Staff (4m) 9 Leveling Staff (5m) 10 Leveling Staff (6m) 11 Engineers Measuring Chain 30m 12 Metallic Tape 30m, 13 Arrows (Metal) 14 Mallet and pegs (wooden) 15 Spirit Level 16 Invar Tape 30m 17 Surveyor compass 18 Stand 19 Chain 20 Metallic Tape 10m, 21 Pegs 22 Hammer 23 Plane Table and its accessories 24 Metallic Tape 5m, 25 Prism Square 26 Clinometer 27 Tachometer -1 Compaction Factor Apparatus 2 Slump Test Apparatus 3 Vee bee Consisto meter 4 Cement Mortar Moulds 5 Cylindrical Moulds 6 Cube Moulds 7 Le Chatelier Flask 8 Le-Chatelier Apparatus 9 Le-Chatelier Water Bath 10 Standard Vicat’s Apparatus 11 Flexure Strength Testing Machine 12 Cement Tensile Testing Machine 13 Needle Vibrator 14 Digital Weighing Balance 15 Digital Platform Balance 16 Cement autoclave 17 Trowel 18 spatulla 19 guinia 20 spirit level 21 Floor Tile testing machine (Flexure and abrasion) with all accessroies 22 Weight 23 Weight Hanger 24 steel scale 25 Micrometer 26 Thickness and Length Gauge for Flakness and Elongation Index 27 I.S. Sieves Set 28 Rebar Detector 29 Enfflorscence Test apparatus 30 Automatic Mortar Mixer, Digital, Capacity 5 L 31 Rebar Locators, Diameter and Cover Meters with software 1 pH meter 20 x 2 line back lighted LCD display., pH Meter complies to USP and DIN standards, alphanumeric splash waterproof polyester keyboard with soft keys., Range 0° to 150° C. No’s 1 2 Turbidity meter 0 - 10,000 NTU , ± 2% of reading plus 0.01 NTU (0 to 1000 NTU) No’s 1 ± 5% of reading (1000 to 4000 NTU) ± 10% of reading (4000 to 10,000 NTU) , Response Time: less than 6 seconds, Sample Size: 30ml, Operating Temperature: 0° - 50°C 3 Test tube Glass Test Tube - 150 mm tall x 16 m with 14 mm inside diameter. Approximate volume is 22 mL. Borosil No’s 24 4 MAGNETIC STIRRER WITH HOT PLATE Number of stirring Positions: 1 No’s 1 Calibration: Automatic Calibration Type of Drive Motor: Motorless magnetic coil type Display Option/Output Read out Option: Digital Magnetic stirrer is: with a hot plate or some other means for heating the liquid Controller type: Electronically controlled and Programmable Speed Control Accuracy of set speed (+/-) (RPM): 0 Maximum Stirring capacity per position: 2000 milliliter Ceramic Top Plate Material, Digital Front Panel, Last run memory CE certified Product (seller to furnish supporting document to Buyer on demand) SPEED Speed Mode: Variable Speed Minimum Speed Possible (RPM): 50 Maximum Speed (RPM) of variable speed mode equipment: 1600 DIMENSIONS External Dimension: (Height )200 millimeter External Dimension: Width 200 millimeter External Dimension: Depth: 50 millimeter Body Material: Stainless Steel Finish of Body material: Powder coated Top plate Finish: Ceramic coated STIR BAR Stir bar cover material: PTFE QUOTED ALNICO MAGNET Stir Bar length: 200 millimeter TOP PLATE Top plate area shape: Circular Circular Top plate diameter: 1000 millimeter Top plate Finish: Ceramic coated 5 Burette 50 ml, made of Borosil No’s 6 6 Burette. stand with rod,clam & boss head Base 8 x 5, Rod 2411 long, 1.1tree finger clamp No’s 10 7 Conical Flask 250 ml, made of Borosil No’s 6 8 Pippette, 25 ml, made of Borosil No’s 10 9 Rubber gloves, Nitrile rubber (L Size) Box 4 10 Apron White Cloth Lab Apron (M size) No’s 5 11 Fluoride Ion Meter (with Fluoride electrode) TYPE / NOMENCLATURE / PROTECTION No’s 1 Type of Meter / Analyzer: Bench Type Functional nomenclature: Multi Parameter Water Quality Analyzer Ingress Protection (Main Unit): IP 56 Calibration: Automatic COMPENSATION / CORRECTION Temperature correction: Automatic Salinity Correction: Automatic DISPLAY / STORAGE Type of Display: LCD with Backlight Display Digit Size: 30 millimeter Number of Digits in Display: 5 Number of parameters displayed simultaneously: 3 Memory (in Data Sets): 500 Internal memory (GB): 64 Date /time Stamp in Entries: Yes Connectivity interface: USB, RS 232 Power Source: Alkaline Batteries (Non-Rechargeable), Mains (230 ±10 Volts / 50 Hz AC) Battery Size, if Non Rechargeable Battery: AA Battery Chemistry, if Rechargeable Battery: Li-ion Voltage of each Battery 1.5 Volt Number of Batteries required for operation: 4 Number of Batteries Inclusive in the Scope of Supply: 4 Battery Capacity (mAh): 800 Battery Life: 800 hour Suitable Adapter to be supplied to make the equipment Work on 230 V ± 10 %, 50 Hz: Yes 12 Prestaltic pump Flow range – 0.1ml/hr to 1000ml/hr Accuracy – ±2% Digital display of functions and time Auto-stop with audible No’s 1 alarm Battery back-up stores memory in case of power failure. 13 High Volume Air Sampler Flow Rate 39 to 60 cfm for MFC; typically 42 to 45 cfm for VFC; Volumetric Flow Control Accuracy ±1% deviation over 24-hr period;Power Requirements 110/220 ± 10V, 100W; Precision of Pressure Stabilization 0.05 Mpa; Flow/pressure recorder with circular charts, 4 (10 cm) dia.; range 10 to 65 cfm No’s 24 14 Nessler Tube Borosil glass, 3.3mm thick, and 100ml capacity No’s 6 15 Glass test tubes Glass Test Tube - 150 mm tall x 16 m with 14 mm inside diameter. Approximate volume is 22 mL. made of Borosil No’s 24 16 Laboratory hot air over Digital laboratory over (18x18x18), Hot oven 450mm digital No’s 1 17 Thermometer Digital display, accuracy +/- 1c No’s 3 18 Vertical Autoclave Product: Vertical Autoclave. Pressure: 10-20 Psi, Usage: Laboratory, Power Rating: 1.5 KW, Size: 22L, Outer Material: Mild Steel, Inner Material: No’s 1 Stainless Steel 19 Filtration Assembly With Oil Free Vacuum Pump filtration assembly consisting of suspended solids filter holder with filter support for 47 mm dia and borosil glass filtration flask, capacity 1 ltr vacuum pipe, oil free vacuum pump. I. Oil tree vacuum pump 25 litr , 2.ss holder 47 mm, 3 glass flask 1000ml Set 1 20 Petri Dish Borosilicate Glass Petri Dish 90mm No’s 10 21 Silica Crucible (50m1) Heat Resistant, Strong build quality {10 piece of each). can be used in muffle furnace at high tempareture up to 1000 degree celcius No’s 10 22 Silica Crucible (100 ml) Heat Resistant, Strong build quality {10 piece of each). can be used in muffle furnace at high tempareture up to 1000 degree celcius No’s 10 23 BOD Bottle 300ml bottle , made of borosil No’s 30 24 Digital COD Digester (for 10 ml COD vials) Digestion capacity 10-16 vials Vial volume Maximum 10m1 Vial dimension 16 x 100 mm Digestion temperature 20C- 200° C No’s 1 25 Chloroscope Square unbreakable test tube - 2 Nos, glass dropper with rubber test-1No, O-Toluidine reagent-125ml, packed in thermocol box, to check chlorine in drinking water from 0.25ppm to 2ppm No’s 6 26 Porcelain dish 80mm dia, 40 ml No’s 6 27 Measuring cylinder 250 ml made of Borosil No’s 6 28 Beaker 250 ml made of Borosil No’s 6 29 Filter Paper 42 & 45 no. No’s 12 30 Funnel made of Borosil No’s 6 Geo Tech. Engg 1 I.S. Sieves 20 cm diameter brass Aperture size 4.75 mm, 2.36mm, 1.18mm, 600micron, 300 micron,150 micron and 75 micron as per IS 460 Sieves 20 cm diameter brass Aperture size 4.75 mm, 2.36 mm, 1.18mm, 600 micron, 300 micron,150 micron and 75 micron as per IS 460 Set 2 2 Pycnometer As per IS:2386 ( Part 3 ) Consist of a 1 kg Glass Jar with Brass Cone No’s 6 3 Liquid Limit Device Casagrande grooving tools and gauge block with AC Supply Compliance with IS:2720 (Part 5), IS:9259 No’s 6 Consists of a hard rubber base Casagrande Grooving Tool Gauge Block 4 Plastic Limit Set Glass plate, Flexible Spatula, Brass / SS rod, Moisture Dish & Porcelain Dish. No’s 6 5 Core Cutter As per IS:2720 (Part 29), Min. 100 mm dia x 130 mm long, Steel Dolly 25 mm high and 100 mm dia,Rammer with Steel Rod. No’s 4 6 Density bottle 100 ml, made of borosilicate No’s 5 7 Density bottle 50 ml, made of borosilicate No’s 5 8 Proctor Test Apparatus for heavy compaction Proctor Test Apparatus for heavy compaction, Material - Mild Steel as per the IS:2720 (Part 8), Rammer and Base Plate, made of Mild steel No’s 1 150 mm dia, 127.3 mm height 2,250 ml volume. Rammer:- 4.9 kg 9 Direct shear apparutus . moterised with 12 speed . As per IS : 2720 ( part XIII ) Ref. Standards IS :11229, 2720 (Part 13) No’s 1 Type of Shear : Direct / Residual Measurement Operation : Motorised Rates of Strain (mm/min) : 1.25, 0.625, 0.25, 0.125, 0.05, 0.025, 0.01, 0.005, 0.002, 0.001, 0.0004, 0.0002 Specimen Size : 60 x 60 x 25 mm Digital Indicator, Load Cell 2KN, Displacement Sensor Range : 0-20mm. Shear Box Assembly, This assembly comprises of : Halves of the Shear Box 2 Nos. Plane Gripper Plate - 2 Perforated Gripper Plate - 2 Porous Stone - 2 Top Loading Pad - 1 Base Plate - 1 Specimen Cutter - 1 Min normal stress - 3 kg/cm2 Operation : Motorised 10 Laboratory Vane Shear Apparatus As per the IS:2720 (Part 30) with special motor, Rotation 0.10/sec. No’s 1 Rate of rotation : 1/60 rpm Suitable for operation on 220 V, 50 Hz, Single Phase, AC supply. Container 1 No.Set of 4 Springs, (one each of capacity 2 kg-cm, 4 kg-cm, 6 kg-cm and 8 kg-cm min) 11 Triaxial shear test Apparatus Speeds between 0.0005 mm/min and 6.00 mm/min. No’s 1 Maximum Platen dia :- 130mm Tri-axial Cell , Stationary Bushing,38mm dia:- Ref Standard: IS : 2720 (Part XII) For testing specimen of size 38mm dia x 76mm long. • Triaxial Cell consists of Perspex chamber with anvil and loading plunger • The cell is easily split by releasing four type rods. • It is leak proof upto 10 bar (10 kg/cm2) fluid pressure. • An oil plug and an air vent are provided for introducing a thin layer of oil over water. This provides effective sealing at the plunger for long duration tests. • The cell is fitted with four sleeve packed valves of no volume change type of base. Cell Consisting of followings: - • Top loading pad, Perspex, 38 mm dia. 1 No. Plain Perspex disc 38mm dia x 6 mm thick 1 pair. Porous Stone 38mm dia x 6 mm thick. 1 pair. Sheath stretcher for 38 mm dia specimen 1 No. Two way split former for 38 mm dia specimen 1 No. Rubber sheath for 38 mm dia specimen 12 Nos. Drainage tube (short), 38 mm 4 Nos. Drainage tube (long), 38 mm 4 Nos. “O’ rings for 38mm dia specimen 4 Nos. Split Mould, 38mm dia 1 No. Top loading pad 38mm (plain) 1 No. Max Pressure - 12kg/cm2 . oil pump - 1 variable pressure - 16 bar pressure Suitable for operation on 220 V, 50 Hz, Single Phase,AC supply. •Pressure Transducer, 20 bar (20 kg/cm2) capacity, an LVDT (Displacement Sensor) having a range of 0- 20mm mm and a 3 - Channel Digital Indicator Digital Indicator :- Mode of Display : Micro controller multi line alpha numeric VFD display for all simultaneous channel Power supply Voltage : 220V, 50Hz, Single Phase Load cell:- Capacity : 10 kN Load Cell excitation : 5 V, DC 12 Consolidation Apparatus As per IS:2720 (Part-XV), Analogue No’s 1 Should Consolidation Cell Assembly - min 3 Nos Fixed ring with Guide ring— Min 3 Nos Channelled base with water inlet— 3 Nos Water Jacket — 3Nos Different Set of weights WaterTank with assembly, 13 Sieve Shaker Sieve Shaker, Motorized, with Built-in Digital Timer, • A digital timer adjustable from 0-99 minutes is incorporated as an integral part of the equipment. No’s 1 • The Sieve Shaker can carry up to 8 sieves of 20cm diameter, also supplied with 30cm adaptor. It is driven by a ¼ HP geared motor. , • The Sieve Table is inclined from the vertical axis and the direction of inclination changes progressively in the clockwise direction. In addition to the gyratory motion of the table, there is a tapping motion as well. Suitable for operation on 220 V, 50 Hz, Single Phase, AC supply. 14 Electronic Balance Upto 500g, and 5 kg No’s 1 15 Glass measuring cylinder 1000 ml No’s 5 16 Stop Watch Accuracy : 0.01 Seconds No’s 2 17 Hydrometer Apparatus Hydrometer, Range: 0-20, 20-40, 40-60, 60-80, & 80-100 No’s 5 18 Metre scale 300 mm length, steel made No’s 2 19 Shrinkage Limit Set As per IS : 2720 (Part 6), Porcelain Evaporating Dish, Shrinkage Bath, Glass Cup, Min. Three Metal Prongs, Perspex Plain Plate Spatula, Glass Cylinder, 25 ml x 0.5 ml, Mercury. No’s 2 20 Sample Extractor application - soil Extractor, Capacity - 5 Ton, Automation Grade Manual No’s 1 21 Infra - Red Moisture Metre As per the IS: 2720 (Part 2) No’s 1 The speed of drying (about 30 min), The infrared radiation is controlled by a voltage regulator. The instrument is provided with an indicator lamp. The balance scale (drum) is divided in terms of moisture percentage on wet weight basis, which are read directly from it. Graduations are from 0 to 100% in 0.2 % divisions. Suitable for operation on 220 V, 50 Hz, Single phase,AC Supply. Capacity: min 5g approx. Sensitivity : min 10 mg approx. Range : 0 to 100% moisture content on wet weight basis. Reading accuracy : min ± 0.20% Probable error : min ± 0.25% in the lower range upto compared to 25% and ± 1% for moisture contents Oven methods : above 50% Equipment consisiting of :- Infra Red Lamp Thermometer (L-shaped) 22 Unconfined Compression Test Digital Load Frame with LCD 50 kN Capacity with 4 Speed variations. No’s 1 • Horizontal Clearance - 265 mm • Vertical clearance - 700 mm • Maximum Platen dia - 130 mm • Maximum Platen Travel - 100mm • Ram Dia - 50mm • Suitable for operation on 220 V, 50 Hz, single phase, AC supply. • Ring capacity - 2 kN • Dial Gauge - 25 mm, 0.01 mm least count. • Mould - 38 mm dia × 76 mm long • Rubber Sheath - 38 mm dia specimen 23 Sand bath Device with tray, stove, palet, knife, steel top with powder coated, 230V, single phase No’s 1 24 Non Corridible air tight container or can 100 ml, 200 ml, 500 ml, 1000 mlSet of 6 for each Nos 24 25 Thermometer 0.5c - 60c No’s 2 26 Water bath 15 Litre capacity, temperature controlled, LED water bath No’s 1 MOM Lab. 1 Beam deflection Apparatus structural lab A mild steel beam 2.5 cm x 3 mm in cross section and 100 cm long is pinned to two supports 70 cm apart situated symmetrically. One of the ends can be fixed or given a known slope by applying a known moment at the end with the help of suspended loads. At the other end also a known moment can be applied at various points along the span of the beam. No’s 1 2 Abrasion Testing Machine for Glezed Tile voltage 230, Power 100 Watt, 50 Hz, single Phase AC Supply No’s 1 3 Flexure Strength Testing Machine Flexure Testing Machine Electrically Operated, Material of Construction: No’s 1 Weight of the Load Frame: Min. 130kg Hydraulic System: With Min. 15 liters, hydraulic oil feed and fuel pump separately, 0.5 hp, 1 Ph, 220V AC motor driven two-speed hydraulic pump.Standard confirm to:- Conforms to IS 516 and IS : 14858, Machines conforming to ASTM C39.
Tender Notice
Key Value
41.48 Lakhs
41.48 Lakhs
41.48 Lakhs