TENDER FOR I Love Patna At Paryatan Ghat Display work.- 2.29 Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish lead upto 50 mand lift up to 1.5 m 1 2.29.1 All kinds of soil 2 2.28 Supplying and filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete. 2.0 Pile Work 20.2 Boring providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap ,to carry a safe working load not less than specified ,excludingthe cost of steel reinforcement but including the cost of boring ,with bentonite solution and temprory casing of appropriate length for setting out and removal of same and length of pile to embedded in thepile cap etc.all complete,including removeof excavatede earth with all lifts and leads (Length of pile for payment shall be measured up to bottom of pile cap). 3 20.2.2 400 mm dia Piles 20.4 Extra over item No. 23.3 for providing addition bulb inunder reamed piles,under specified dia meter (Only the quantity of extra bulbs are to be paid) 4 20.4.2 400 mm dia piles 3.0 Concrete Work 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level. 5 4.1.6 1:3:6 (1 Cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) 4.0 Reinforced Cement Concrete Works 5.9 Centring and shuttering including strutting, propping etc. and removal of form for: 6 5.9.1 Foundations, footings, bases of columns, etc., for mass concrete. 7 5.9.2 Wall (any thickness) including attached pilasters Butteresses ,plinth and string courses etc 5.9.3 Suspended floors, roofs, landings, balconies and access platform 3.3/5.33. Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cementcontent as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and including retard setting of concrete, improve workability without impairing strength and admixtures in recommended proportions as per IS: 9103 to accelerate,reinforcement,durability as per direction of Engineer-incharge. 8 5.33.1 All work upto plinth level 5.22 Reinforcement for RCC work including straightening. Cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars 9 5.22.7A TMTC-500- 8mm dia . 10 5.22.7B TMTC-500-10 mm dia. 11 5.22.7C TMTC-500-12 mm dia. 12 5.22.7D TMTC-500-16mm dia 5.00 Plaster & Finishing Works 13.11 12 mm cement plaster of mix 13 13.11.4 1:6 (1 cement : 6 coarse sand) 8.13 Providing and laying Polished Granite Store Flooring In required design and patterns , linear as well as curvilinear portion of the thick stone slab over 20mm (average)thick base of cement mortary 1:4(cement :4 coarse sand)laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing curing and polishing etc.all complete as specified an as directed by the Engineer in Charge 14 8.13.1 Polished Granite Stone slab jet black Cheary Red ,Elite Brown Cat Eye or equivalent 15 13.80A.2 Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 13.46A Finishing walls with Premium Acrylic smooth exterior paint with silicone additives of required shade. 16 13.46A.1 New work (Two or more coats applied @ 1.43 ltr / 10 sqm. Over and including base coat of water proofing cement paint applied @ 2.20 kg / 10 sqm). 6.00 Flooring Works 17 11.72 Providing designation 100 A one brick flat soling joints filled with local sand including cost of watering taxes, royalty all complete as per building specification and direction of E/I. Total SUB HEAD-I :-WIRING POINTS 7.7 Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required. 18 7.7.3 10 sq. mm, 2 core 19 7.7.8 35 sq. mm, 3.5 core SUB HEAD-I :-WIRING POINTS TOTAL SUB HEAD-I :-SWITCHEARS & DBS 2.1 Providing and fixing following capacity double pole/ TP&N sheet metal switch disconnector fuse unit in the existing metal panel board with rewireable type fuses including drilling holes in metal panel, making connections etc as required. 20 2.1.1 16 Amp, double Pole 21 2.1.2 32 Amp, double Pole 22 2.1.3 63 Amp, double Pole 2.4 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required 23 2.4.1 lOO A, 30 KA, FPMCCB 24 2.4.2 125 A,36 KA, FPMCCB 2.5 Providing and fixing following capacity busbar chamberwith 4 strips of suitable size made of copper, heavy duty, complete with all accessories including connections, earthing the body etc. as required. 25 2.5.1 63A 26 2.5.2 100 A 2.6 Providing and fixing following capacity double pole/ four pole OFF-load changeover switches with side handle operation, in sheet enclosure in existing metal board, including drilling holes in metal panel, making connections etc. as required. 27 2.6.5 100 A, four pole 2.7 Providing and fixing following capacity four pole ON-loadpanel mounted changeover switches inside the existingcubical panel board including drilling holes in cubicle panel,making connections etc. as required. 28 2.7.5 160 A 2.8 Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCBilsolator) 29 2.8.6 8 way, Double door 30 2.8.7 12 way, Double door 2.9 Supplying and fixing following way, horizontal type threepole & neutral, sheet steel, MCB distribution board, 415volts, on surface/ recess, complete with tinned copper bus -bar, neutral bus bar, earth bar, din bar, interconnections,powder painted including earthing etc. as required, (Butwithout MCB/RCCB/lsolator) 31 2.9.1 4 way ( 4 + 12 ), Double door, horizontal type 2.12 Supptying and fixing following rating, 24Al4L5 volts, Ccurve, miniature circuit breaker suitable for inductive loadsof following poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required 32 2.12.1 6 A to 32A, Single pole 33 2.12.2 6 A to 32 A, SP&N 34 2.12.8 40 A to 63 A, TP&N 2.15 Supplying and fixing following rating, double pole, 240volts, isolator iri the existing MCB DB complete withconnections, testing and commissioning etc. as required. 35 2.15.1 40 AmPs 36 2.15.2 63 AmPs 37 2.18 Supplying and fixing following rating, four pole, (threephase and neutral), 415 volts, residual current circuitbreaker (RCCB), having a sensitivity current upto 30milliamperes in the existing MCB DB complete withconnections, testing and commissioning etc. as required. 38 2.18.2 40 Amp 39 2.18.3 63 Amp 40 2.20 Providing and fixing M.V. danger notice plate of 2O0 mm X 150 mm, made of mild steel at least 2 mm thick, vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 41 2.21 Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel at least 2 mm thick, vitreous enameled white on both sides. and with inscription in single red colour on front side as required. 42 2.22 Supplying and fixing wall mounted metal board of weldedconstruction, fabricated with minimum 35 mm X 35 mm X 5mm angle iron frame work, with 25 mm X 6 mm flat iron asintermediate members including painting etc. as required. SUB HEAD-I :-SWITCHEARS & DBS TOTAL SUB HEAD-II :-EARTHING 43 3.2 Earthing with G.l. earth pipe 4.5 metre long, 40 mm diaincluding accessories, and providing masonary enclosurewith cover plate having locking arrangement and wateringpipe etc with charcoal/coke and salt as required. 44 3.21 Providing chemical/mineral maintenance free earthingsystem comprising of copper coated earth electrode 3metre length and 17.2 mm outer dia along with 25 kg earthconductivity enhancing back fill mineral compound for eafthelectrode to fill up the excavated earth and earth inspectionpit etc. as required. SUB HEAD-II :-EARTHING TOTAL SUB HEAD-II :-LIGHTNING CONDUCTOR 45 4.1 Providing and fixing lightning conductor finial, made of 25 mm dia 300 mm long, copper tube, having singte prong on top, with 85 mm dia 3 mm thick copper base plate including holes etc. complete as required. 46 4.4 Jointing copper/ G.l. tape (with another copper/ G ltape,base of the finial or any other metallic object ) by riverting/ nut bolting sweating and soldering etc. as required. 47 4.6 Providing and fixing copper tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For vertical run) SUB HEAD-II :-LIGHTNING CONDUCTOR TOTAL SUB HEAD-II :- MV/HT CABLE LAYING 7.1 Laying of one number PVC insulated and pVC sheathed /XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. 48 7.1.1 Above 35 sq. mm SUB HEAD-II :-MV/HT CABLE LAYING TOTAL 49 MR-1 Providing and fixing UNILinear Flex IP68UNILinear Flex is IP68 cove lighting with reliable performance and excellently waterproof, anti-dust LED strips with professional design for vivid colors. 50 1 m3 51 2 m3 52 3 m3 53 4 mt 54 5 nos 55 6 mt

Tender Notice

46331854

Indian


PATNa

Bihar

November 30, 2024

Key Value

72.35 Lakhs

72.35 Lakhs

72.35 Lakhs

To Download Tender Document Click on the below link

TENDER FOR I Love Patna At Paryatan Ghat Display work.- 2.29 Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish lead upto 50 mand lift up to 1.5 m 1 2.29.1 All kinds of soil 2 2.28 Supplying and filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete. 2.0 Pile Work 20.2 Boring providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap ,to carry a safe working load not less than specified ,excludingthe cost of steel reinforcement but including the cost of boring ,with bentonite solution and temprory casing of appropriate length for setting out and removal of same and length of pile to embedded in thepile cap etc.all complete,including removeof excavatede earth with all lifts and leads (Length of pile for payment shall be measured up to bottom of pile cap). 3 20.2.2 400 mm dia Piles 20.4 Extra over item No. 23.3 for providing addition bulb inunder reamed piles,under specified dia meter (Only the quantity of extra bulbs are to be paid) 4 20.4.2 400 mm dia piles 3.0 Concrete Work 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level. 5 4.1.6 1:3:6 (1 Cement: 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) 4.0 Reinforced Cement Concrete Works 5.9 Centring and shuttering including strutting, propping etc. and removal of form for: 6 5.9.1 Foundations, footings, bases of columns, etc., for mass concrete. 7 5.9.2 Wall (any thickness) including attached pilasters Butteresses ,plinth and string courses etc 5.9.3 Suspended floors, roofs, landings, balconies and access platform 3.3/5.33. Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cementcontent as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and including retard setting of concrete, improve workability without impairing strength and admixtures in recommended proportions as per IS: 9103 to accelerate,reinforcement,durability as per direction of Engineer-incharge. 8 5.33.1 All work upto plinth level 5.22 Reinforcement for RCC work including straightening. Cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars 9 5.22.7A TMTC-500- 8mm dia . 10 5.22.7B TMTC-500-10 mm dia. 11 5.22.7C TMTC-500-12 mm dia. 12 5.22.7D TMTC-500-16mm dia 5.00 Plaster & Finishing Works 13.11 12 mm cement plaster of mix 13 13.11.4 1:6 (1 cement : 6 coarse sand) 8.13 Providing and laying Polished Granite Store Flooring In required design and patterns , linear as well as curvilinear portion of the thick stone slab over 20mm (average)thick base of cement mortary 1:4(cement :4 coarse sand)laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing curing and polishing etc.all complete as specified an as directed by the Engineer in Charge 14 8.13.1 Polished Granite Stone slab jet black Cheary Red ,Elite Brown Cat Eye or equivalent 15 13.80A.2 Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 13.46A Finishing walls with Premium Acrylic smooth exterior paint with silicone additives of required shade. 16 13.46A.1 New work (Two or more coats applied @ 1.43 ltr / 10 sqm. Over and including base coat of water proofing cement paint applied @ 2.20 kg / 10 sqm). 6.00 Flooring Works 17 11.72 Providing designation 100 A one brick flat soling joints filled with local sand including cost of watering taxes, royalty all complete as per building specification and direction of E/I. Total SUB HEAD-I :-WIRING POINTS 7.7 Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required. 18 7.7.3 10 sq. mm, 2 core 19 7.7.8 35 sq. mm, 3.5 core SUB HEAD-I :-WIRING POINTS TOTAL SUB HEAD-I :-SWITCHEARS & DBS 2.1 Providing and fixing following capacity double pole/ TP&N sheet metal switch disconnector fuse unit in the existing metal panel board with rewireable type fuses including drilling holes in metal panel, making connections etc as required. 20 2.1.1 16 Amp, double Pole 21 2.1.2 32 Amp, double Pole 22 2.1.3 63 Amp, double Pole 2.4 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required 23 2.4.1 lOO A, 30 KA, FPMCCB 24 2.4.2 125 A,36 KA, FPMCCB 2.5 Providing and fixing following capacity busbar chamberwith 4 strips of suitable size made of copper, heavy duty, complete with all accessories including connections, earthing the body etc. as required. 25 2.5.1 63A 26 2.5.2 100 A 2.6 Providing and fixing following capacity double pole/ four pole OFF-load changeover switches with side handle operation, in sheet enclosure in existing metal board, including drilling holes in metal panel, making connections etc. as required. 27 2.6.5 100 A, four pole 2.7 Providing and fixing following capacity four pole ON-loadpanel mounted changeover switches inside the existingcubical panel board including drilling holes in cubicle panel,making connections etc. as required. 28 2.7.5 160 A 2.8 Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCBilsolator) 29 2.8.6 8 way, Double door 30 2.8.7 12 way, Double door 2.9 Supplying and fixing following way, horizontal type threepole & neutral, sheet steel, MCB distribution board, 415volts, on surface/ recess, complete with tinned copper bus -bar, neutral bus bar, earth bar, din bar, interconnections,powder painted including earthing etc. as required, (Butwithout MCB/RCCB/lsolator) 31 2.9.1 4 way ( 4 + 12 ), Double door, horizontal type 2.12 Supptying and fixing following rating, 24Al4L5 volts, Ccurve, miniature circuit breaker suitable for inductive loadsof following poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required 32 2.12.1 6 A to 32A, Single pole 33 2.12.2 6 A to 32 A, SP&N 34 2.12.8 40 A to 63 A, TP&N 2.15 Supplying and fixing following rating, double pole, 240volts, isolator iri the existing MCB DB complete withconnections, testing and commissioning etc. as required. 35 2.15.1 40 AmPs 36 2.15.2 63 AmPs 37 2.18 Supplying and fixing following rating, four pole, (threephase and neutral), 415 volts, residual current circuitbreaker (RCCB), having a sensitivity current upto 30milliamperes in the existing MCB DB complete withconnections, testing and commissioning etc. as required. 38 2.18.2 40 Amp 39 2.18.3 63 Amp 40 2.20 Providing and fixing M.V. danger notice plate of 2O0 mm X 150 mm, made of mild steel at least 2 mm thick, vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 41 2.21 Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel at least 2 mm thick, vitreous enameled white on both sides. and with inscription in single red colour on front side as required. 42 2.22 Supplying and fixing wall mounted metal board of weldedconstruction, fabricated with minimum 35 mm X 35 mm X 5mm angle iron frame work, with 25 mm X 6 mm flat iron asintermediate members including painting etc. as required. SUB HEAD-I :-SWITCHEARS & DBS TOTAL SUB HEAD-II :-EARTHING 43 3.2 Earthing with G.l. earth pipe 4.5 metre long, 40 mm diaincluding accessories, and providing masonary enclosurewith cover plate having locking arrangement and wateringpipe etc with charcoal/coke and salt as required. 44 3.21 Providing chemical/mineral maintenance free earthingsystem comprising of copper coated earth electrode 3metre length and 17.2 mm outer dia along with 25 kg earthconductivity enhancing back fill mineral compound for eafthelectrode to fill up the excavated earth and earth inspectionpit etc. as required. SUB HEAD-II :-EARTHING TOTAL SUB HEAD-II :-LIGHTNING CONDUCTOR 45 4.1 Providing and fixing lightning conductor finial, made of 25 mm dia 300 mm long, copper tube, having singte prong on top, with 85 mm dia 3 mm thick copper base plate including holes etc. complete as required. 46 4.4 Jointing copper/ G.l. tape (with another copper/ G ltape,base of the finial or any other metallic object ) by riverting/ nut bolting sweating and soldering etc. as required. 47 4.6 Providing and fixing copper tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For vertical run) SUB HEAD-II :-LIGHTNING CONDUCTOR TOTAL SUB HEAD-II :- MV/HT CABLE LAYING 7.1 Laying of one number PVC insulated and pVC sheathed /XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. 48 7.1.1 Above 35 sq. mm SUB HEAD-II :-MV/HT CABLE LAYING TOTAL 49 MR-1 Providing and fixing UNILinear Flex IP68UNILinear Flex is IP68 cove lighting with reliable performance and excellently waterproof, anti-dust LED strips with professional design for vivid colors. 50 1 m3 51 2 m3 52 3 m3 53 4 mt 54 5 nos 55 6 mt