Tender For Provision Of Deficient Br Items For Smq And Omq At Afs Purnea Under Age I Af Purnea; 1 Brick 1) Compressive strength IS03495 (Part-II) As per IS-5454 as gien under :- A 330/- Checks for visual and Dimensional characteristic s shall also be carried out as per IS-5454 2) Water absorption IS-3495 (Part-II) Lost size Sample size Permissible Nos of defective bricks A 330/- A 1001 to 35000 5 0 3) Efflorescence IS-3495 (Part-I) 10001 to 35000 10 0 A 330/- 2 Coarse Aggregate 1) Sieve Analysis IS-3495 (Part-I) One test for every 15 cum of aggregates of part thereof brought to site. A 660/- 2) Flakiness Index IS-2386 (Part-I) One test for every 15 cum of aggregates or part these of brought to site. A 250/- 3) Estimation of deleterious materials IS-2386 (Part-I) One test for every 100 cum of aggregate or part thereof. A 600/- 4) Organic impurities IS-2386 (Part-I) One test per source of supply. C 275/- 5) Moisture content IS-2386 (Part-II) Regularly as Required A 330/- 6) Specific Analysis IS-2386 (Part-I) One test for every 15 cum of FA or part thereof when brought to site. A 330/- 3 Fine aggregate 1) Sieve Analysis IS-2386 (Part-I) One test for every 15 cum of FA or part thereof when brought to site. A 660/- 2) Test for clay, silt and impurities. IS-2386 (Part-I) One test for every 15 cum of FA or part thereof of when brought to site. A 500/- 3) Specific gravity IS-2386 (Part-II) One for each source of supply B 330/- 4) Test for organic impurities IS-2386 (Part-II) One test for each source of supply. C 275/- 5) Moisture content IS-2386 (Part-II) Regularly as required subject to 2 tests / per day when being used. A 330/ 4 Cement 1) Setting time IS-4031-63 Reaffirmed 1980 Once for each consignment or as and when required. B 500/- 2) Soundness IS-4031-63 Reaffirmed 1980 Once for each consignment or as and when required. C 550/- 3) Compressive strength IS-4031-63 Reaffirmed 1980 Once for each consignment or as and when required. B 550/- 4) Fineness IS-4031-63 Reaffirmed 1980 IS-199 Once for each consignment or as and when required. C 275/- 5 Structural concrete 1) Slump test or compacting factor test or VEE-BEE time IS-119 The Min frequency of sampling of concrete of each grade shall be as under :- A 300/- (i) Random sample shall be carried out to cover mixing units. 2) Compressive strength IS-516 Qty of conc. In the work (M3) 1-5 6-15 16-30 31-50 51 and above No of samples 1 2 3 4 4+1 for each addl 50 CuM. Or part thereof A 900/- 2) As per IS-456-2000 clause. 14 for frequency of sampling. 6 Cement flooring Tiles / Terrazzo tiles 1) Water absorption IS-1237 (Appx ‘D’) 6 Tiles out of 18 B 330/- Samples 18 tiles from each source of supply selected at Random. 2) Wet Transverse IS-1237 (Appx ‘F’) 6 Tiles out of 18 B 660/- 3) Resistance to wear IS-1237 (Appx ‘F’) 6 Tiles out of 18 C 1000 / 7 Timber 1) Specific gravity and weight IS-1708-1960 Minimum 3 samples from a lot of 4 Cum or 250 pieces of seasoned timber. B 250/- 2) Moisture content IS-1708-1960 A 250/ 8 Water for Constn purpose 1) Test for acidity IS-456 & 3015 Once at the state of approval of source of water B 500/- Also refer clause 4.3 of IS456 and its subsequent clauses regarding suitability of water. 2) Test for alkalinity IS-456 & 3015 3) Test for solid content IS-456 & 3015 9 Welding of steel work Visual Inspection Test IS:822-1970 Clause 7.1 100% by visual inspection 750/- Specialized tests, their method and frequency to be decided on consideration of their importance by the Accepting Officer. 10 Timber paneled and glazed door/ window shutters (including factory made shutter) (a) Dimensions, sizes workmanship and finish IS : 1003-1977 (Pt-I) Frequency of sampling from each lot shall be as under :- A 240/- 1 Lot size 2 Sample size 26 to 50 5 51 to 100 8 101 to 150 13 151 to 300 20 301 to 500 32 501 to 1000 50 1001 and above 80 (b) STRENGTH TE IS-1303-1990 From each lot 5% of the factory made shutter shall be manufacture tested for strength tests. 1) Slamming 2) Impact Indentation IS-1303-1990 3) Shock resistance IS-1303-1990 4)Edge loading IS-1303-1990 11 Ply wood (IS-303-1989) (a) Moisture content IS-1734-1983 (Part-I) Six test pieces cut from each of the Boards selected as per table-I shall be subjected to tests B 500/- Sampling shall be as per IS-7835-1975 Table-2 12 Veneered wood particle board (Medium Density) IS3097 – 1985) (a) Density IS-635 (Part-I) Three test specimen from each sample (size 15 mm x 75 mm) C 125/- Sampling shall be done as per IS-3487-83 Clause 2 with moisture meter. (b) Moisture content IS-2360 (Part-III) Three test specimen from each sample (size 150 mm x 75 mm) A&B 125/- IS-3487-83 clause 2 with moisture (c) Water absorption IS-2360 – (Part-16) Three test specimen from each sample (size 300 mm x 300 mm) A 125/- Moisture meter. (d) Swelling due to surface absorption IS-2360 (Part-17) Three test specimen from each sample (size 125 mm x 100 mm) A 125/- (e) Swelling in water IS-2360 (Part-17) Three test specimen from each sample (size 200mm x 100 mm) A 125/- (f) Modules of rupture IS-2360 (Part-IV) Three test specimen as per IS2380-1977. Three test as per specimens as per IS-2385. B 180/- (g) Screw withdrawal strength IS-2360 (Part-IV) Three test specimens as per IS2380-1977. Three test specimens as per IS-2385. C 250/- LEGEND A-Site Lab B-Zonal Lab C-National test house / SEMT WING / Engg. College

Tender Notice

46624957

Military Engineer Services

Indian


Bihar

December 31, 2024

Key Value

43.55 Lakhs

43.55 Lakhs

43.55 Lakhs

To Download Tender Document Click on the below link

Tender For Provision Of Deficient Br Items For Smq And Omq At Afs Purnea Under Age I Af Purnea; 1 Brick 1) Compressive strength IS03495 (Part-II) As per IS-5454 as gien under :- A 330/- Checks for visual and Dimensional characteristic s shall also be carried out as per IS-5454 2) Water absorption IS-3495 (Part-II) Lost size Sample size Permissible Nos of defective bricks A 330/- A 1001 to 35000 5 0 3) Efflorescence IS-3495 (Part-I) 10001 to 35000 10 0 A 330/- 2 Coarse Aggregate 1) Sieve Analysis IS-3495 (Part-I) One test for every 15 cum of aggregates of part thereof brought to site. A 660/- 2) Flakiness Index IS-2386 (Part-I) One test for every 15 cum of aggregates or part these of brought to site. A 250/- 3) Estimation of deleterious materials IS-2386 (Part-I) One test for every 100 cum of aggregate or part thereof. A 600/- 4) Organic impurities IS-2386 (Part-I) One test per source of supply. C 275/- 5) Moisture content IS-2386 (Part-II) Regularly as Required A 330/- 6) Specific Analysis IS-2386 (Part-I) One test for every 15 cum of FA or part thereof when brought to site. A 330/- 3 Fine aggregate 1) Sieve Analysis IS-2386 (Part-I) One test for every 15 cum of FA or part thereof when brought to site. A 660/- 2) Test for clay, silt and impurities. IS-2386 (Part-I) One test for every 15 cum of FA or part thereof of when brought to site. A 500/- 3) Specific gravity IS-2386 (Part-II) One for each source of supply B 330/- 4) Test for organic impurities IS-2386 (Part-II) One test for each source of supply. C 275/- 5) Moisture content IS-2386 (Part-II) Regularly as required subject to 2 tests / per day when being used. A 330/ 4 Cement 1) Setting time IS-4031-63 Reaffirmed 1980 Once for each consignment or as and when required. B 500/- 2) Soundness IS-4031-63 Reaffirmed 1980 Once for each consignment or as and when required. C 550/- 3) Compressive strength IS-4031-63 Reaffirmed 1980 Once for each consignment or as and when required. B 550/- 4) Fineness IS-4031-63 Reaffirmed 1980 IS-199 Once for each consignment or as and when required. C 275/- 5 Structural concrete 1) Slump test or compacting factor test or VEE-BEE time IS-119 The Min frequency of sampling of concrete of each grade shall be as under :- A 300/- (i) Random sample shall be carried out to cover mixing units. 2) Compressive strength IS-516 Qty of conc. In the work (M3) 1-5 6-15 16-30 31-50 51 and above No of samples 1 2 3 4 4+1 for each addl 50 CuM. Or part thereof A 900/- 2) As per IS-456-2000 clause. 14 for frequency of sampling. 6 Cement flooring Tiles / Terrazzo tiles 1) Water absorption IS-1237 (Appx ‘D’) 6 Tiles out of 18 B 330/- Samples 18 tiles from each source of supply selected at Random. 2) Wet Transverse IS-1237 (Appx ‘F’) 6 Tiles out of 18 B 660/- 3) Resistance to wear IS-1237 (Appx ‘F’) 6 Tiles out of 18 C 1000 / 7 Timber 1) Specific gravity and weight IS-1708-1960 Minimum 3 samples from a lot of 4 Cum or 250 pieces of seasoned timber. B 250/- 2) Moisture content IS-1708-1960 A 250/ 8 Water for Constn purpose 1) Test for acidity IS-456 & 3015 Once at the state of approval of source of water B 500/- Also refer clause 4.3 of IS456 and its subsequent clauses regarding suitability of water. 2) Test for alkalinity IS-456 & 3015 3) Test for solid content IS-456 & 3015 9 Welding of steel work Visual Inspection Test IS:822-1970 Clause 7.1 100% by visual inspection 750/- Specialized tests, their method and frequency to be decided on consideration of their importance by the Accepting Officer. 10 Timber paneled and glazed door/ window shutters (including factory made shutter) (a) Dimensions, sizes workmanship and finish IS : 1003-1977 (Pt-I) Frequency of sampling from each lot shall be as under :- A 240/- 1 Lot size 2 Sample size 26 to 50 5 51 to 100 8 101 to 150 13 151 to 300 20 301 to 500 32 501 to 1000 50 1001 and above 80 (b) STRENGTH TE IS-1303-1990 From each lot 5% of the factory made shutter shall be manufacture tested for strength tests. 1) Slamming 2) Impact Indentation IS-1303-1990 3) Shock resistance IS-1303-1990 4)Edge loading IS-1303-1990 11 Ply wood (IS-303-1989) (a) Moisture content IS-1734-1983 (Part-I) Six test pieces cut from each of the Boards selected as per table-I shall be subjected to tests B 500/- Sampling shall be as per IS-7835-1975 Table-2 12 Veneered wood particle board (Medium Density) IS3097 – 1985) (a) Density IS-635 (Part-I) Three test specimen from each sample (size 15 mm x 75 mm) C 125/- Sampling shall be done as per IS-3487-83 Clause 2 with moisture meter. (b) Moisture content IS-2360 (Part-III) Three test specimen from each sample (size 150 mm x 75 mm) A&B 125/- IS-3487-83 clause 2 with moisture (c) Water absorption IS-2360 – (Part-16) Three test specimen from each sample (size 300 mm x 300 mm) A 125/- Moisture meter. (d) Swelling due to surface absorption IS-2360 (Part-17) Three test specimen from each sample (size 125 mm x 100 mm) A 125/- (e) Swelling in water IS-2360 (Part-17) Three test specimen from each sample (size 200mm x 100 mm) A 125/- (f) Modules of rupture IS-2360 (Part-IV) Three test specimen as per IS2380-1977. Three test as per specimens as per IS-2385. B 180/- (g) Screw withdrawal strength IS-2360 (Part-IV) Three test specimens as per IS2380-1977. Three test specimens as per IS-2385. C 250/- LEGEND A-Site Lab B-Zonal Lab C-National test house / SEMT WING / Engg. College