Patna Dairy - Bihar

43456375 tender for supply of electric item contractor siemens 45 amp 3tf46 contractor siemens no * 3tf33 mcb 20 amp 4 pole mcb 63 amp 4 pole wire connector 10 amp wire connector 40 amp wire connector 25 amp wire connector 63 amp mcb 80 amp 3 pole mcb 25 amp 4 pole mcb 32 amp 4 pole volt meter 0 500v 96mm x 96mm ampere meter 0 100 amp mcb 40a 3 pole...

East Central Railway - Bihar

43024047 supply of three phase submersible pump controller panel, fully automatic star delta motor starter suitable for 40 hp with isi marked contractor and isi marked relay having in built single phase preventer, volt meter, electron ic single phasing preventer ( spp ) unit, auto / manual / by pass modes, selector switch, push button, motor on / powe r on led lamp indication relay range 36 60 amp, ac 3 415 volt 50 hz coil voltage 380 volt ac, make bentex, hav ells, l&t, bch, cromption, kerlosker or reputed make [ warranty period: 30 months after the date of delivery ] ...

East Central Railway - Bihar

43023991 supply of three phase submersible pump controller panelthree phase submersible pump controller panel, three phase submersible pump controller panel, fully automatic star delta motor starter, suitable fo r 20 hp, with isi marked contactor and isi marked relay having in bult single phaseing preventer, volt meter, elect ronic single phasing preventer ( spp ) unit, auto / manualy / by pass modes, selector switch, push button, motor on / po wer on led lamp indication relay range20 33 amp, ac 3 415 volt 50 hz coil voltage 380 volt ac, make bentex, h avells, l&t, cromption, kirlosker, bch or reputed make [ warranty period: 30 months after the date of delivery ] ...

Department of Labour Resources - Bihar

42247571 bids are invited for boq boq soldering iron 25 w , digital insulation tester , micrometer out side 0 to 25 mm , micrometer out side 25 to 50 mm , thermometer digital , vernier bavel protector blade with acute , iron 1500 w , dvd player , single stage regulator , welding pipe , welding blow pipe , energy meter , volt meter , ac phase wound slip ring motor , induction , scraper traingular , marking block , dial vernier caliper universal type , digital knife , soldering desoldering station , smps , measuring tap 5 meter , hammer , chisel 200 mm , chisel 175 mm , chisel 150 mm , centre punch taparia , try square , allen key 10 pcs , welding helmet glass , leather hand gloves , file double cut 300 mm , file single cut 200 mm , file second cut 250 mm , file square second cut 250 mm , file half round 150 mm , file second cut 150 mm total quantity : 307...

Department of School Education - Bihar

41508200 bids are invited for title boq moltar and pestol , beaker , test tube , caivity side , spirst lamp , wick for sprit lamp , boloting papper , camil hair brush , t.s of ovalance , distiled water , liquid detergent , non iodised nacl , boric acid , magnesium sulphate , acetic acid , mettyl akokel , aceptocamine , test tube holder , glars slab , vertiner calipes , parallelogram , im clined plane , hookes law , ohms law apparatus , meter bridge , resistance box , resistance coil , volt meter , am meter , am mete , plug key , drawing board , prism , mirror , mouth piep , mike stand , mike wire , battery a4 15v , battery 9v , extension board , amplifier 250watt , sound box srx 120dxm , aux cable , speaker scm 10w tower , switch 6amp , switch 16amp , socket 6amp , socket 16amp , mica board 40 by 30 , mica board 20 by 15 , led bulb 14watt , china nail 1inch , china nail 1 by 2 , china nail 2 inch , china nail 2 by 1 inch , hamer , electric tape , screw difreent size , grip , combition piep , long cock , short cock , teflon tape , basin tape , down piep , conection piep , angle wall cock , plug , angle cock , thread total quantity : 570...

State Bank Of India - Bihar

39130217 tender for hiring of brand new 20 kva diesel generator set (acoustic enclosure type) at sbi,babubarhi(a) diesel engine: (i) make: kirloskar/ cummins /greaves / mahindra / ashok leyland/eicher (ii) multi cylinders, water cooled, 1500 rpm, diesel engine (b) alternator specification: (i) make: stamford/kirloskar/ kirloskar electric/crompton greaves. (ii) capacity: 20 kva at 0.85pf 415 volts, 3 phases, 4 wires, 50 hz (iii) the regulation from no load to full load shall not exceed 2.0 %. (iv)the alternator shall be of brush less type design, self excited of robust construction. the alternator shall be suitable for continuous rating with ambient temperatures of 40 degrees centigrade. the voltage control shall be through automatic voltage regulator unit (avr). the avr unit shall de excite the alternator in case of short circuit. (v) it shall withstand 10% overload for one hour every 12 hour duration on operation. vi. the alternator shall confirm drip proof constructions per is: 4722 (at least ip 23). (c.) sound proof enclosure: (i) noise level permitted: wherever acoustic insulation is provided 75 db at 1.0 meter from dg set under free field condition meeting cpcb norms. (ii)shall be factory fabricated specially with superior quality acoustic insulation so as to achieve the permissible noise level within the prescribed norms of state/ central pollution control board. (iii) the container shall be weather proof housing the d.g. set, fuel tank. fresh air will enter from the alternator end. blowers of adequate capacity will be provided, if necessary, to provide sufficient air for cooling & ensure operating temperature is within prescribed limits specified by engine manufactures. (iv) hinged / sliding door will be provided on either side. sufficient maintenance access shall be provided in the design of the acoustic enclosure. (d) age of diesel generator set : brand new 20 kva dg set with sound proof acoustic enclosure eco friendly, factory fitted and tested as per ie rule and pollution control board complaint. (e) the diesel engine shall be robust heavy duty construction. it shall deliver the required bhp at the shaft of the coupled alternator to deliver the rated output of required kva. the speed governor shall be mechanical auto controlled, adjusting automatically to the desired load conditions. (f) the engine shall be fitted with all standard accessories as detailed above. it shall be possible to start the engine from the amf panel & locally. (g) the operation of the dg set shall be on automatically on mains failure with a pre set time. the engine will be shut down automatically on resumption of mains power with a preset time delay through amf panel. (h) the dg set shall be mounted on wheels or foundation as required. automatic mains failure panel (wherever required): (i)amf control panel for auto starting of the dg set shall be fabricated from the ms sheet steel 14 gauge and shall be of compartmental design. the main supporting framework shall be of angle iron or of heavier gauge sheet metal. the panel shall be self supporting design, dust and vermin proof, dead front and fully interlocked with isolating switches. the panel mounted switches shall have defeat interlocks for testing and inspection. (ii)the panel shall be designed so as to facilitate inspection, cleaning and repairs. the clearance between phase to phase and phase to earth or metal parts shall be as per relevant is standards. the metering instruments like volt meter, ammeter, etc. shall be flush mounted and shall be of 1.0 class accuracy and of standard design size shall be 96 mm x 96. all indication lamps shall be of neon type / digital. the panel shall be tested at site before commissioning. (iii)all wiring inside the panel shall be done with copper conductors / cables/solid copper links. all the hinge doors shall be earthed. adequate ventilation for the panel shall be provided. logic diagram of operation of switches shall be painted on the panel. the name plates for each feeder shall be of engraved design and pasted to the respective switch gear. a)type : cubical, front operated with detachable cable gland plates at top and bottom. b) enclosure : 14g crca suitably rust inhibited with powder coated with 7 tank treatment process and provided with square section rubber gaskets ip52 enclosure. c) mounting : floor /wall mounted with supporting legs or blank panel d. circuit breakers : double breaker for dg set and mains isolation. e) instrument panel fitted with : ac voltmeter (0 600v) voltmeter selector switch. ac ammeter ammeter selector switch kwh meter frequency meter running hour meter iv. indicating lamps for load on mains. load on generator set fails to start low lubricating oil pressure high water temperature (v) sets of push buttons for generator start / stop emergency trip auto hooter auto / manual /test / selector switch generator on / off manually. mains on / off – manually (vi) battery charger static, comprising of transformer rectifier trickle / boost auto. dc ammeter mains voltage monitor amf logic with three attempt starting facility (vii) protection over voltage under voltage over load short circuit over speed. under frequency & earth fault...

Central Institute Of Plastics Engineering And Technology - Bihar

37975858 tender for repair & maintenance of lt panel 1 supply of 1600a fp 50ka edo acb with microprocessor release for over current and short circuit protection 01 2 vpr 3p 01 3 battery charger 24v 10a 02 4 aux.contractor 01 5 digital volt meter 01 6 digital kwh meter 01 7 red indication led lamp 03 8 yellow indication led lamp 03 9 blue indication led lamp 03 10 installation of the above acb after removing the existion acb, removal of all bus bar termination, fixing the acb and reconnection of the same as required 01 11 installation of the relays,auxillary contractor, indication lamp, rewiring the same and checking and redoing the interlocking system as reqd. 01...

East Central Railway - Bihar

37754518 supply of d.c volt meter , range 0 to 200 volt, panel mounted ( panel cut diameter = 112.5 to 115 mm ) circular base, flash type, accuracy class 1.5, dimension : od =135 / + 2 mm, id= 112 / + 2 mm, height = maximum 51mm ( without top flange ) confirming to is:1248 ( latest ) . g.c. & calibration test certificate to be submitted at the time of delivery. [ warranty period: 30 months after the date of delivery ] ...

Labour Department - Bihar

36420249 bids are invited for boq boq fuses , cables twisted nmetallic sheathed cable underground feeder cable ribbon cable metallic sheathed , lux meter , tong tester or clamp meter , soldering iron , temperature controlled soldering iron , thermometer digital , sun shine recorder , solar cell based sunlight radiation meter , magnetic compass , cut models of photo voltaic cell assembly , cut model of lead acid battery , lead acid battery 12v, 40ah, 75ah , lead acid battery 12v, 100 ah , solar energy trainer with grouping of solar cells , solar tracker demonstrator kit , halogen lamp with stand for illumination of solar panels in lab , motorized bench grinder , battery charger , solar photovoltaic module , solar panels , solar charge controller with dusk to dawn automatic switching , solar charge controller with manual switch day lighting , solar lantern , spirit level , anemometer , dc table fan , a.c. voltmeter m.i , volt meter , ammeter mc , ammeter mccentre zero , power factor meter , rheostat , a.c. energy meter , digital wattmeter , frequency meter , dc led lamp , inverter with battery , solar street light , rubber gloves , cotton gloves , gum boots , safety goggles , safety helmet , first aid kit , fire buckets total quantity : 446...

Department of Labour Resources - Bihar

35981101 bids are invited for plumber tool items equivalent metric , water closet , sight rail and bonning rod , rachet pipe die , double face hammers , dormat, pickaxe, spade, girmale , measuring steel tape , combination plier insulated , screw driver insulated , electrician screw driver , heavy duty screw driver , electrician screw driver , punch centre , knife double bladed electrician , neon tester , steel rule graduated both , hammer cross peen with handle , pipe vice cast iron , hand vice , table vice , hacksaw frame , file flat , file half round , file round , pliers long nose insulated , pliers flat nose insulated , pliers, round nose insulated , de metric spanner , gauge wire imperial , portable electric drill machine , pliers side cutting , wire stripper adjustable length , hammer ball peen with handle , tool kit box , allen key , scissors blade , torque wrench , pipe cutter to cut pipe , pipe cutter to cut pipes , try square , multi meter analog , wire cutter and stripper , out side micrometer , tap set , mccb , elcb and rccb , fuses , multimeter , megger , tong tester clamp meter , soldering iron , temperature controlled soldering iron , magnetic compass , cut models of photo voltaic , solar charge controller , solar lantern assembly sets , clinometer , spirit level , anemometer , ac voltmeter mi , volt meter , ammeter mc , ammeter mccentre zero , phase sequence indicator , frequency meter , rubber gloves , cotton gloves , gum boots , safety goggles , safety helmet , first aid kit total quantity : 931...

Indian Oil Corporation Limited - Bihar

34928921 annual maintenance contract ( for 33kv / 6.6 kv ht switchyard, substation equipment ) ( arc items ) for electrical works and general cp / psp / mov related works at erpl patna pump station 2 complete quarterly manintenance of 33 kv / 6.6 kv ht switchyard equipments, substation equipments, pump station equipments / area, under erpl patna station jurisdiction as defined in scope of work & technical specifications. list of equipments are as follows: ( a ) transformer & ngr ( b ) circuit breaker ( vcb ) ( c ) air circuit breaker ( acb ) ( d ) current transformer ( e ) potential transformer ( f ) isolatorswitch ( g ) earth switch ( h ) lightning arrestor ( i ) post insulator ( j ) protection system of entire electrical system ( k ) capacitor bank ( l ) mov actuatorrates will be inclusive of boarding, lodging, local conveyance, mobilization & demobilization, manpower, equipment, tools & tackles and all other incidental cost. 3 complete half yearly manintenance of 33 kv / 6.6 kv ht switchyard equipments, substation equipments, pump station equipments / area, under erpl patna station jurisdiction as defined in scope of work & technical specifications. list of equipments are as follows: ( a ) transformer & ngr ( b ) circuit breaker ( vcb ) ( c ) air circuit breaker ( acb ) ( d ) current transformer ( e ) potential transformer ( f ) isolatorswitch ( g ) earth switch ( h ) lightning arrestor ( i ) post insulator ( j ) protection system of entire electrical system ( k ) capacitor bank ( l ) mov actuatorrates will be inclusive of boarding, lodging, local conveyance, mobilization & demobilization, manpower, equipment, tools & tackles and all other incidental cost. 4 complete yearlymanintenance of 33 kv / 6.6 kv ht switchyard equipments, substation equipments, pump station equipments / area, under erpl patna station jurisdiction as defined in scope of work & technical specifications. list of equipments are as follows: ( a ) transformer & ngr ( b ) circuit breaker ( vcb ) ( c ) air circuit breaker ( acb ) ( d ) current transformer ( e ) potential transformer ( f ) isolatorswitch ( g ) earth switch ( h ) lightning arrestor ( i ) post insulator ( j ) protection system of entire electrical system ( k ) capacitor bank ( l ) mov actuatorrates will be inclusive of boarding, lodging, local conveyance, mobilization & demobilization, manpower, equipment, tools & tackles and all other incidental cost. 5 relay coordination, testing and calibration ( relay calibrator being used for the work should be calibrated by an nabl authorized agency ) of all relays as defined in scope of work & technical specifications to be done once in a year. ( 1 unit of this item constitutes 138 relays listed in scope of work & technical specifications ) . these 138 relays constitute of numerical relays and electromagnetic relays ( mostly contact multiplier like k86, tc supn, transformer aux, etc ) rates will be inclusive of boarding, lodging, local conveyance, mobilization & demobilization, manpower, equipment, tools & tackles and all other incidental cost. work schedule will be as per instruction of site engineer / eic. 6 testing and calibration ( meter calibrator being used for the work should be calibrated by an nabl authorized agency ) of all meters as defined in scope of work & technical specifications to be done once in a year. ( 1 unit of this item constitutes 165 meters listed in scope of work & technical specifications ) .rates will be inclusive of boarding, lodging, local conveyance, mobilization & demobilization, manpower, equipment, tools & tackles and all other incidental cost. work schedule will be as per instruction of site engineer / eic. 7 testing and calibration ( through nabl certified laboratory ) of all electrical measuring instruments as defined in scope of work & technical specifications to be done once in a year. ( 1 unit of this item constitutes 10 measuring instruments listed in scope of work & technical specifications ) . rates will be inclusive of boarding, lodging, local conveyance, mobilization & demobilization, manpower, equipment, tools & tackles and all other incidental cost. work schedule will be as per instruction of site engineer / eic. 8 routine breakdown visit as defined in scope of work & technical specifications.routine breakdown maintenance means identifying reason for malfunction / not working / not running of electrical equipment on s witching ( as per instruction of eic ) , by a team of ( 1+1 ) engineer + assistants, in time schedule given by engineer in charge ( quantity of routine breakdown maintenance will be number of days as per schedule by eic, considering 8 working hours per day ) rates will be inclusive of boarding, lodging, local conveyance, mobilization & demobilization, manpower, equipment, tools & tackles and all other incidental cost. 9 minor breakdown manintenance as defined in scope of work & technical specifications. minor faults in the installed items are where no major breakdown has occurred. in minor breakdown maintenance, system is to be stabilized in maximum duration of 12 working hours from the time of instruction by se / eic and shall mean a team of ( 1+4 ) engineer + assistants. rates will be inclusive of boarding, lodging, local conveyance, mobilization & demobilization, manpower, equipment, tools & tackles and all other incidental cost. work schedule will be as per instruction of site engineer / eic. 10 major breakdown manintenance as defined in scope of work & technical specifications.work shall be termed as major breakdown, if items such as crane, specialized lifting equipment, highly skilled man power deputation, major spares replacements, etc. are required. [ spare shall be given by iocl or extra payment shall be made for this ] , in this, system is to be stabilized in time schedule given by engineer in charge. rates will be inclusive of boarding, lodging, local conveyance, mobilization & demobilization, manpower, equipment, tools & tackles and all other incidental cost. 11 attending power failure to system in cp / rcp / mov station as defined in scope of work & technical specifications. stations have lt power supply controlled by mcb / contactor. restoration after power failure / supply interruption to the input terminal of main system installed, is only in scope of this work. power failure or interruption issue is to be attended by ( restoring supply ) / ( bypassing inverter ) within 6 hours ( from the time of instruction by se / eic ) . in case of fault in inverter / battery / battery charger, it must be repaired and reinstalled in station within 72 hours ( from the time of instruction by se / eic ) [ cost of any part replacement will be paid extra ] . contractor has to arrange for repairing of inverter / battery / battery chargerrates will be inclusive of boarding, lodging, local conveyance, mobilization & demobilization, manpower, equipment, tools & tackles and all other incidental cost. work schedule will be as per instruction of site engineer / eic. 12 service assistance for psp checking, inspecting proper functioning of lights and exhaust fans, refilling distilled water in batteries, cleaning of solar panels, checking fence energizer, checking earth pit & anode bed condition, checking system functionality, upkeeping of jbs, cleaning trenches and earth pits, greasing and painting of rusted parts in cp stations complete in all respectunder the supervision of iocl personnel as per direction of e i c. contractor has to arrange distilled water & lodgingarrangement for the worker on his own expense. one personnel of contractor may commute withiocl personnel in office vehicle during cp / rcp / sv station visits, but he has to reach to vehicle start point and return from vehicle end point at his own expense. all required material, tools & tackles, equipment is to be arranged by contractor.rates will be inclusive of boarding, lodging, local conveyance, mobilization & demobilization, manpower, equipment, tools & tackles and all other incidental cost. work schedule will be as per instruction of site engineer / eic. 1 unit is for 1 cp station. [ maintenance of 2 cp stations shall require 1 semiskilled manday ] 13 service assistance for psp survey ( during day period ) including greasing of psp connection, carrying measuring instruments to tlp site, bolting of tlp post door, cleaning of tlps and clearing nearby vegetations complete in all respect including all tools & tackles and consumables under the supervision of iocl personnel as per direction of e i c. contractor has to arrange lodging of his worker on his own expense. one personnel of contractor may commute withiocl personnel in office vehicle during psp in row, but he has to reach to vehicle start point and return from vehicle end point at his own expense. all required material, tools & tackles, equipment is to be arranged by contractor. for psp measurement, iocl meters will be used. rates will be inclusive of boarding, lodging, local conveyance, mobilization & demobilization, manpower, equipment, tools & tackles and all other incidental cost. work schedule will be as per instruction of site engineer / eic.1 unit is for psp survey of all pipelines in 1 km of row. [ psp survey of all pipelines in 10km shall require 1 semiskilled manday ] 14 service assistance for mov / pcv actuator maintenance. actuators are of make biffi, rotork and auma. assistance in mov actuator maintenance, complete in all respect under the supervision of iocl personnel as per direction of eic. rates will be inclusive of boarding, lodging, local conveyance, mobilization & demobilization, manpower, equipment, tools & tackles and all other incidental cost. work schedule will be as per instruction of site engineer / eic.1 unit is for 1 mov actuator maintenance. maintenance of 10 mov actuator shall require 1 semiskilled manday ] 15 filtration of transformer oil by stream line filter machine provided by the contractor for improving the insulation strength of oil to the required strength as per specification given below ( excluding the supply of oil ) . a ) filtration of transformer oil till bdv as per instruction of eic is attained. b ) topping up of oil. c ) releasing all the air from air release plug & bucholz relay. d ) to and fro transportation of filter machine and equipments. e ) conducting transformer oil tests as mentioned in scope of work. 16 electrical composite items 17 caution board 18 supply and install caution boards for switchyard voltage system as per iss 2551 1963 complete in english / hindi / local language. 19 earthing plate 20 supply & installation of g.i. earthing plate outside the buildings. the item also includes grouting of the plate. the item should be complete in all respect including all materials, tools, tackels etc. and as per direction of eic / site engineer. 21 earth strip / wire / rope / cable supply, installing and testing of earthing strip / wire / rope / cable for completely making the earthing grid system by supplying, laying the gi / cu strip and making all the necessary welding joints, connecting to the earthing electrodes and existing earthing grid etc., complete as per directions of the site engineer / engineer in charge, including the cost of all labour, tools, materials, etc. complete in all respect: 22 50 mm x 6 mm g.i. earthing strip 23 40 mm x 5 mm g.i. earthing strip 24 25mm x 4 mm copper flat 25 25mm x 3 mm copper flat 26 gi wire ( 8 swg ) 27 gi wire / rope 35 sq. mm 28 gi wire / rope 10 mm diameter 29 copper cable as per specifications 100 sq.mm 30 copper cable as per specifications 10 sq.mm 31 earthing grid ( gi strip ) : supply, installation and testing of 75 mm x 10 mm gi earthing strip for completely making the earthing grid system by supplying, laying the g.i. strip and making all the necessary welding joints, connecting to the earthing electrodes and existing earthing grid etc. complete in all respects including consumables, tools / equipments and labour as per directions of engineer in charge / site engineer. 32 earthing electrode 33 supplying, installation, testing of gi earthing electrode including the supply and installation of the g.i. cover, charcoal etc. complete in all respects including consummables, tools / equipments and labour as per directions of engineer in charge / site engineer. 34 pvc conduit pipes supply, installation, fixing in position, pvc conduit pipes, of isi marked , in concrete, brick work etc. during or after construction by making grooves in the wall, ceiling etc. cutting threads and jointing the pipes with pvc couplers, providing necessary tees, bends, junction boxes etc. with 12 swg gi wire inside conduit without joint for concealed wiring, including making good the concrete, brick work, surfaces etc. complete as per direction of site engineer / engineer in charge including cost of all labour, materials etc.: 35 19 mm 36 25 mm 37 32 mm 38 supply & fixing of pvc conduit on surface: supply and fixing of following size of pvc conduit along with the accessories in surface including cutting the wal land making good the same in case of reessed, conduit as required: note: only isi marked conduits shall be used. 39 20 mm 40 25 mm 41 32 mm 42 40 mm 43 50 mm 44 supply & fixing of pvc casing / caping: providing and fixing following size of pvc casing and capingon surface as required. note: only isi marked caping and casing shall be used. 45 15 mm x 10 mm 46 20 mm x 10 mm 47 25 mm x 10 mm 48 30 mm x 10 mm 49 40 mm x 20 mm 50 50 mm x 20 mm 51 supply & fixing chequered plates 52 supply, installation and fixing of ms chequered plates of 5mm thickness. job includes cutting to size, supply of hinges / hooks for lifting, tag welding with support wherever required, painting including supply of paint, supply of all material and labor complete in all respect 53 hard stone laying ( sw yard ) : providing and spreading 40mm size approved hard stone chips around transformer yard in one layer of 100mm thick. job includes dressing of soil surface and laying the aggregate in uniform laying and density as per direction of site engineer aggregate shall be measured in boxes of size 1.1 / 2m x 1.1 / 2m x 1.1 / 2m which shall be taken as 1m3. the boxes will be supplied by contractor free of charge for measuring purpose. 54 supply of 40mm size stone chips per m3 55 spreading the stone chips per m3 56 putty application 57 application of pvc putty / m seal putty on lighting fixtures / jn. boxes / glands / switch boards etc. to avoid entering water / insects / any other type of things as per direction of the engineer in charge. note: putty will be supplied by owner free of cost. 58 supplying and fixing of gi route marker 59 suppplying cable route marker with 10 cm x 10 cm x 5 mm thick gi plate with inscription thereon, bolted / welded to 35 mm x 35 mm x 6 mm angle iron, 60cm long and fixing the same in ground as required. job includes painting with one coat of redoxide and finishing paint. 60 33kv ( e ) / 22 kv ( ue ) heat shrinkable straight through pvc / xlpe armoured aluminium cable jointing ( including cost of jointing kit ) : making straight through cable joint for power ( pvc / xlpe ) armoured cable and following sizes and grade including cutting, stripping of cable insulation all complete with labour including travel, transportation, boarding and lodging of the cable jointer and materials excluding cost of jointing kit as per standard and direction of the engineer in charge. note: work to be done in timeline as mentioned in tender document. 61 3 x 400 sqmm 62 salt and charcoal for plate earthing: extra for using below given salt and charcoal for plate earthelectrode as required. 63 96 kg charcoal and 5 kg salt 64 240 kg coke and 5 kg salt 65 salt and charcoal for pipe earthing: extra for using below given salt and charcoal for pipe earth electrode as required. 66 64 kg charcoal and 5 kg salt 67 160 kg coke and 5 kg salt 68 provide first aid boxes 69 supply and fixing of first aid boxes as per ie rules, 1956 clause 43 ( 2 ) , including necessary clamps, bolts, rawl plugs, etc. breachking and making good the walls if required. all complete with labour and materials as per the direction of engineer in charg 70 fire buckets 71 supply and installation of set of 3 nos. fire buckets on a suitable stand including fabrication and erection of iron stand and painting of stand and buckets, all complete with labour and materials as per the direction of engineer in charge 72 providing and fixing following rating metal clad, tp&n switch fuse unit, 415 / 500 volts, without h.r.c. fuses including drilling holes on the board, connections, earthing the body etc. as required. 1.isi marked hrc fuses shall be used. 2.tpn of english electric / l&t / crompton / havells / standard make shall be used. 73 16 a tpn hrc sfu 74 32 a tpn hrc sfu 75 63 a tpn hrc sfu 76 100 a tpn hrc sfu 77 l series mcb suitable for lighting and other domestic loads: supplying and fixing of following rating 240 volts, 50hz, 10ka l series, miniature circuit breacker ( suitable for lighting and other domestic loads and conforming to is 8828: 19 ) of single poles in the existing mcb db complete with connections, testing and commissioning etc. as required. note: isi marked mcbs of havells / loadster / indo kopp make shall be used. 78 5 to 32 amp 79 40 amp 80 5 a to 32 a g series mcb suitable for motorl and other inductive loads: supplying and fixing 5 amps. to 32 amps. rating, 240 / 415 volts, 50hz, 10ka g series, miniature circuit breaker ( suitable for motor and other inductive loads and conforming to is 8828: 1996, iec 60898: 2002 ) of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. note: isi marked mcbs of havells / loadster / indo kopp make shall be used. 81 single pole 82 single pole and neutral 83 double pole 84 triple pole 85 triple pole and netural 86 four pole 87 40 a to 63 a g series mcb suitable for motorl and other inductive loads: supplying and fixing 40 amps. to 63 amps. rating, 240 / 415 volts, 50hz, 10ka g series, miniature circuit breaker ( suitable for motor and other inductive loads and conforming to is 8828: 1996, iec 60898: 2002 ) of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. note: isi marked mcbs of havells / loadster / indo kopp make shall be used. 88 single pole and neutral 89 double pole 90 triple pole and netural / 4 pole 91 sp & dp mcb isolator: supplying and fixing following rating, single pole & double pole isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. note: isi marked isolators shall be used. 92 40 amps. single pole 93 63 amps. single pole 94 40 amps. double pole 95 63 amps. double pole 96 80 amps. double pole 97 100 amps. double pole 98 125 amps. double pole 99 tp & fp mcb isolator: supplying and fixing following rating, three pole and four pole, 415 volts, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required.note: isi marked isolators shall be used. 100 40 amps. triple pole 101 63 amps. triple pole 102 80 amps. triple pole 103 100 amps. triple pole 104 125 amps. triple pole 105 40 amps. four pole 106 63 amps. four pole 107 80 amps. four pole 108 100 amps. four pole 109 125 amps. four pole 110 double pole rccb: supplying and fixing following rating, double pole, ( single phase neutral ) , 240 volts, residual current circuit breaker ( rccb ) , isi marked, having a sensitivity current indicated miliamperes in the existing mcb db complete with connections, testing and commissioning etc. as required.note: isi marked rccb shall be used. 111 16 amps., 30 ma 112 16 amps., 100 ma 113 16 amps., 300 ma 114 25 amps., 30 ma 115 25 amps., 100 ma 116 25 amps., 300 ma 117 32 amps., 30 ma 118 32 amps., 100 ma 119 32 amps., 300 ma 120 40 amps., 30 ma 121 40 amps., 100 ma 122 40 amps., 300 ma 123 63 amps., 30 ma 124 63 amps., 100 ma 125 63 amps., 300 ma 126 four pole rccb: supplying and fixing following rating, four pole, ( three phase and neutral ) 415 volts, residual current circuit breaker ( rccb ) , isi marked, having a sensitivity current upto indicated milliamperes in the existing mcb db complete with connections, testing and commissioning etc. as required. note: isi marked rccb shall be used 127 25 amps., 30 ma 128 25 amps., 100 ma 129 25 amps., 300 ma 130 40 amps., 30 ma 131 40 amps., 100 ma 132 40 amps., 300 ma 133 63 amps., 30 ma 134 63 amps., 100 ma 135 63 amps., 300 ma 136 supply & instln. of fuse parts: supply, fixing and connection of following knife type hrc fuse link as per is:13703:1993 & iec 269:1986 of m / s havell / l&t / g ec astholm / standard / mds make or approved equivalent in distribution board etc.all complete with labour and materials as per direction of engineer incharge. 137 knife type 6 100 amp ( fcd00 series ) 138 knife type 125 amp ( hcd00 series ) 139 knife type 32 125 amp ( hcd 1 series ) 140 bolted type 2 32 amp ( hns series ) 141 boltedtype 6 32 amp ( htia series ) 142 boltedtype 80 125amp ( htsd series ) 143 supply and fixing of equipment in panels: supply, fixing and connection of following equipments in panels including small mechanical works and supply of all fixing materials. all complete with labour and materials as per the direction of engineer in charge 144 control contactors 4 contacts for ac control standard coil voltage 25, 110, 240, 415, 50hz type mm00 of l&t equivalent 145 control contactors 8 contacts for ac control standard coil voltage 25, 110, 240, 415, 50hz type mm01 of l&t equivalent 146 control contactors 4 contacts for dc control standard coil voltage 24, 110, 220 type mm00 of l&t or equivalent 147 control contactors 4 contacts for dc control standard coil voltage 24, 110, 220 type mm01 of l&t or equivalent 148 power contactor ( with 1no + 1nc ) upto 25 amp ( ac3 ) for ac standard coil voltage 110, 220, 240, 415 v, 50hz type mnx25 of l&t or equivalent 149 power contactor ( upto 2no + 2 nc ) above 25 amp but upto 45 amp ( ac3 ) for ac standard coil voltage 110, 220, 240, 415 v, 50hz type mnx45 of l&t or equivalent 150 power contactor ( upto 2no + 2 nc ) above 45 amp but upto 140 amp ( ac3 ) for ac standard coil voltage 110, 220, 240, 415 v, 50hz type mnx140 of l&t or equivalent 151 power contactor ( upto 2no + 2 nc ) above 140 amp but upto 400 amp ( ac3 ) for ac standard coil voltage 110, 220, 240, 415 v, 50hz type mnx400 of l&t or equivalent 152 thermal relays type mnxr3 with single phasing protection 0.2 0.33 a to 14 23a ( direct operated ) 153 thermal relays type mnxr4 with single phasing protection 20 33 to 30.0 50.0 a ( direct operated ) 154 thermal relays type mnxr4 with single phasing protection 45 75 to 66 110 a ( direct operated ) with separate mounting 155 thermal relays type mnxr5l with single phasing protection 42 69 a to 180 300 a ( ct operated ) with separate mounting 156 thermal relays type ml0 / ml1 / ml1.5 0.15 0.25 a to 10.0 16.0 a ( direct operated ) contractor 157 thermal relays type ml2 / ml3 9.0 14.0 a to 28.0 42.0 a ( direct operated ) contractor 158 shrouded push button actuator of l&t make tk 3 ( ss 91519 ) or approved equivalent of any color ( green, black, red, yellow, grey or blue ) . 159 automatic ac ammeter ( automatic electric make or approved equivalent ) 96 mm x 96 mm square type block backalite case / flush mounting / moving iron / spring controlled suppressed scale, ct operated ac ammeter / range 0 300 1800 a, ct ratio 300 / ia / accuracy + / 2.5%. 160 automatic ac volt meter ( automatic electric make or approved equivalent ) 96 mm x 96 mm square type block backalite case / flush mounting ac volt meter / range 0 600 accuracy + / 2.5%. 161 installation of current transformer of any rating 162 timer for auto lux switch 163 supply and installation of timer of approved make for autolux switch as per secpfication and direction of the engineer in charge 164 rcbo: supply, fixing and connection of following 240 / 415v, 50hz, with 10ka short circuit capacity residual current circuit breaker with overload and short circuit protection ( confirming to is 12640 2:2001 & iec 61009 2 1 ) of l&t / gec astholm / standard / mds / datar / havles make or approved equivalent in distribution board etc. all complete with labour and materials as per direction of e i c 165 double pole ( four module 25 a ( sensitivity 30 ma ) 166 double pole ( four module 25 a ( sensitivity 100 ma ) 167 double pole ( four module 25 a ( sensitivity 300 ma ) 168 double pole ( four module 40 a ( sensitivity 30 ma ) 169 double pole ( four module 40 a ( sensitivity 100 ma ) 170 double pole ( four module 40 a ( sensitivity 300 ma ) 171 supply & installation of mccb: supply & installation of m / s l&t / english electric / siemens make t.p. molded case circuit breaker ( mccb ) ( confirming to is 8828:1996, iec 60898:2002 ) of following current and breaking capacity rating suitable for 415v, 3ph, 50 c / s ac supply must be accompanied with performance test certificates from manufacturer. the mccb should be supplied with thermal overload relay and magnetic release. 172 10 / 15 / 20 / 30 / 40 / 50 / 60 / 63 / 75 / 90 / 100 a with icu = 10ka 173 110 / 125 / 140 / 150 a with icu = 10ka 174 125 / 140 / 150 / 160 / 175 / 200 / 225 a with icu = 25ka 175 250 / 300 / 350 / 400 a with icu = 35ka 176 supply & installation of led indication lamps: supply and fixing of led indication lamp in the panels. leds shall be provided with leakage voltage protection upto 40v. operating voltage shall be 110v / 220v / 230v / ac / dc, panel cutouts shall be 22.5 / 25.5 / 30.5 mm. terminals shall be shrouded for finger proofing and safety are with captivated washers to hold two lugged ( fork / pin ) wires in one terminal. job includes supply of labor and various undry materials required and finally testing of leds for + following eds 177 red / yellow / amber / green / milky white leds 178 blue led 179 supply & instln. of industerial type plug and sockets : supply, fixing and connection of following inusterial type plugs / sockets ( confirming to is / iec 309 ) of m / s havell / l&t / g ec astholm / standard / mds make or approved equivalent in distribution board etc.all complete with labour and materials as per direction of engineer in charge 180 plug 2 pole+ earth, 250v 20 amp 181 plug 3 pole+ earth, 440v 20 amp 182 socket 2 pole+ earth, 250v 20 amp 183 socket 3 pole+ earth, 440v 20 amp 184 supply and fixing of recessedmetal boxes with phenolic sheet: supply and fixing of metal box of following size ( nominal ) in recess with suitable size of phenolic laminated sheet cover in the front including painting etc. as required. 185 75 mm x 75 mm x 60 mm deep 186 100 mm x 100 mm x 60 mm deep 187 150 mm x 75 mm x 60 mm deep 188 150 mm x 150 mm x 60 mm deep 189 180 mm x 100 mm x 60 mm deep 190 200 mm x 125 mm x 60 mm deep 191 200 mm x 150 mm x 60 mm deep 192 200 mm x 150 mm x 75 mm deep 193 200 mm x 250 mm x 75 mm deep 194 200 mm x 150 mm x 100 mm deep 195 gi cable tray 196 supply, installation & fixing of prefabricated perforated gi cable trays with tray cover of width 150 mm, 300 mm, 450 mm & 600 mm as per site requirement for laying of cables with standard rung spacings. load for support span of 2.5 meter as 30, 60, 75 & 90 ( in kg / mtr ) respectively with concentric static load as 70 kg at the centre, with materials, labour, tools and tackles, consumables etc , as per directions of site engineer / engineer in charge. 197 aluminium cable tray 198 supply, installation & fixing of prefabricated perforated aluminium cable trays with tray cover of width 150 mm, 300 mm, 450 mm & 600 mm as per site requirement for laying of cables with standard rung spacings. load for support span of 2.5 meter as 30, 60, 75 & 90 ( in kg / mtr ) respectively with concentric static load as 70 kg at the centre, with materials, labour, tools and tackles, consumables etc , as per directions of site engineer / engineer in charge. 199 supply erection and installation of cable conduits made up of gi pipes of medium class, subject to owners approval, in already made trenches, on walls, concrete structures etc. including supply and installation of all the necessary pipe fittings such as bends, sockets, elbows, tees, etc. the job also includes bending, threading, binding, clamping, providing spacere, plugs, packings, bushing etc. as required for laying of cables, complete in all respects including consumables, tools / equipments and labour a per directions of engieer in charge / site engineer. 200 gi pipe with diameter 20 mm 201 gi pipe with diameter 25 mm 202 gi pipe with diameter 37 mm 203 gi pipe with diameter 100 mm 204 ht cable termination ( 6.6 / 11 kv ) supply, termination and connection of xlpe cable termination kit ( indoor type ) , heat shrinkable sleeve type of raychem / m seal / cci make with all accessories, including cutting ( tools and accessories for termination should meet the selected standards ) , stripping of cable insulation providing copper cable end lugs and cable glands as required, restoration of insulation, supplying and providing the cable supporting clamps, straps, cable tags connection to the terminals of ht panel, vfds, isolators, transformer, dg, mlpu / booster pump motors etc., earthing of armouring, materials, labour, tools and tackles, consumables etc , as per directions of site engineer / engineer in charge: 205 ht cable of size above 3cx240 sq. mm 206 ht cable of size upto 3cx240 sq. mm 207 lt cable end termination for armoured pvc insulated aluminium cable with doublecompression flame proof type brass glanding ( including cost of glands & lugs ) : providing end termination of power / control cable including cutting, stripping, providing & fixing lugs, cable insulation, providing & glanding double compression heavy duty flame proof type brass cable gland conforming to is 12943 ( dowells or approved equivalent ) , wherever specified, providing aluminium lugs, crimping / soldering, as necessary, restoration of insulation / clamping of cable, tagging with aluminium tag, earthing of armour, connection to the equipment terminals etc. all complete with labour and materials as per standard and direction of the engineer incharge 208 2 x 6 sqmm 209 2 x10sqmm 210 2 x16sqmm 211 3 x 4 sqmm 212 3 x 6 sqmm 213 3 x 10 sqmm 214 3 x 16 sqmm 215 3 x 25 sqmm 216 3 x 35 sqmm 217 3 x 50 sqmm 218 3 x 70 sqmm 219 3 x 95 sqmm 220 3 x 120 sqmm 221 3 x 150 sqmm 222 3 x 185 sqmm 223 3 x 225 sqmm 224 3 x 240 sqmm 225 3 x 300 sqmm 226 3 1 / 2 x 25 sqmm 227 3 1 / 2 x 35 sqmm 228 3 1 / 2 x 50 sqmm 229 3 1 / 2 x 70 sqmm 230 3 1 / 2 x 95 sqmm 231 3 1 / 2 x 120 sqmm 232 3 1 / 2 x 150 sqmm 233 3 1 / 2 x 185 sqmm 234 3 1 / 2 x 225 sqmm 235 3 1 / 2 x 240 sqmm 236 3 1 / 2 x 300 sqmm 237 lt cable heat shrinkable indoor / outdoor cable end termination ( including cost ofend termination kit ) : providing end termination of power cable including cutting, stripping, providing lugs, cable insulation, providing and glanding with single / double compression heavy duty brass cable gland conforming to is 12943 , wherever specified, providing aluminium lugs, crimping / soldering, as necessary, restoration of insulation / clamping of cable, tagging with aluminium tag, earthing of armour, connection to the equipment terminals etc. all complete with labour and materials as per standard and direction of the engineer in charge. make of kits shall be of raychem / cci / approved equivalent make 238 upto 3 / 3.5 / 4 x 10 sqmm 239 3 / 3.5 / 4 x 16 sqmm 240 3 / 3.5 / 4 x 25 sqmm 241 3 / 3.5 / 4 x 35 sqmm 242 3 / 3.5 / 4 x 50 sqmm 243 3 / 3.5 / 4 x 70 sqmm 244 3 / 3.5 / 4 x 95 sqmm 245 3 / 3.5 / 4 x 120 sqmm 246 3 / 3.5 / 4 x 150 sqmm 247 3 / 3.5 / 4 x 185 sqmm 248 3 / 3.5 / 4 x 225 sqmm 249 3 / 3.5 / 4 x 240 sqmm 250 3 / 3.5 / 4 x 300 sqmm 251 ht cable joint 252 making straight through joint on 6.6 / 11 kv aluminium / copper xlpe / pvc insulated armoured screened cable, including the supply of required materials such as cable jointing kit ( of heat shrinkable sleeve type of raychem / m seal / 3m ) , materials, labour, tools and tackles, consumables etc , as per directions of site engineer / engineer in charge: for cables of size upto 3 core x 400 sqmm 253 lt cable joint ( 1.1 kv ) making straight through joints on al / cu conductor xlpe / pvc insulated armoured cable including the supply of required materials such as cable jointing kit ( of heat shrinkable sleeve type of raychem / mseal / 3m ) , materials, labour, tools and tackles, consumables etc , as per directions of site engineer / engineer in charge: 254 power cables lt : od upto 20 mm 255 power cables lt : od above 20 mm and upto 40 mm 256 power cables lt : od above 40 mm and upto 60 mm 257 power cables lt : od above 60 mm 258 control cables lt : od upto 20 mm 259 earthing system set ( 06 pits ) 260 supply, installation, testing of earthing system consisting of 6 earth pits of perforated gi pipes earthing electrodes and copper plate terminal block including construction of chamber using cement concrete with earthing pit cover and frame, supply of charcoal, salt etc including supply of interconnecting cables / strips including necessary welding etc complete as per directions of the site engineer, including cost of tools, materials etc complete in all respects. the job shall also include testing of each earth pit and the entire earthing system on whole. ( note: earthing for field instruments shall be provided from station earth grid covered in electrical sor. ) 261 earthing system set ( 03 pits ) 262 supply, installation, testing of earthing system consisting of 3 earth pits of perforated gi pipes earthing electrodes and copper plate terminal block including construction of chamber using cement concrete with earthing pit cover and frame, supply of charcoal, salt etc including supply of interconnecting cables / strips including necessary welding etc complete as per directions of the site engineer, including cost of tools, materials etc complete in all respects. the job shall also include testing of each earth pit and the entire earthing system on whole. ( note: earthing for field instruments shall be provided from station earth grid covered in electrical sor. ) 263 chemical earthpit 264 supply, installation, testing and commissioning of ace ( artificial concept of earthing with chemical rod ) chemrod earthing electrode by digging earthing item includes the supply and installation of the ci / rcc cover in the earth pit, backfilling etc. and construction of chamber; complete including excavation, backfilling and supply of all materials required for making earth pit as per directions of the site engineer, including the cost of all labour, tools, materials etc. complete in all respects. 265 lightining arrestor 266 supply, installation and testing of lightning arrestor on top of the mov buiding or mov cp buiding for diverting lightning surges to the ground. the work shall include supply of 1.2 meter long copper lightning arrestor with 5 spronged phenyl rod base plate etc. complete with necessary insulators including supply and fixing of 50 x 6 mm gi earthing strip of required length and connection to the main earthing grid. 267 rewiinding of fans: rewinding of ceiling / pedestal / exhaust / air circulator fans of all types / sizes / make including 1 phase and 3 phase type exhaust fans max. upto 2.2 kw capacity and supply of super enameled winding wire ( devi dayal make, isi marked insulation materials required ) . this also includes replacement of single / double bearing skf make / bushes ( as per original make ) and overhauling of fan and all jobs related to complete this work in totality. this also includes removal of fans from site, installation and commissioning after testing of rewound fans and replacement of condenser, if required. this also includes transportation from site after dismantling to contractor’s workshop and back to site. note: contractor has to give guarantee for rewinding of above items for a period of six months and if winding is burnt again within six months of working of fans, it has to be rewound again free of cost of contractor. the burnt winding shall be kept by contractor. 268 ceiling / pedestal fans 269 exhaust / air circulators fans. 270 overhauling of exhaust / air circulator fans : overhauling of exhaust / air circulator fans of various types / sizes makes and its bearings including removal from site, cleaning, greasing after degreasing, assembling and fixing in position, testing and commissioning including transportation from site to workplace and back all complete with labour and materials as per directions of engineer incharge. 271 excluding the cost of bearings ( bearings if necessary will 272 including supply and fixing of bearings of skf make ( 2nos. bearings ) 273 overhauling of ceiling / pedestal fans : overhauling of ceiling / pedestal fans of various types / sizes / make and its bearings including removal from site, cleaning, greasing after degreasing, assembling and fixing in position, testing and commissioning including transportation from site to workplace and back. all complete with labour and materials as per directions of engineer incharge. 274 excluding the cost of bearings. ( bearings if necessary will be supplied by owner free of cost. 275 including supply and fixing of bearings of skf make and bushes ( as per original make ) of both sides by contractor. 276 erection of metallic street light: erection of metallic steet light standard of following length in cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation with cement concrete collar of size 0.4 m dia x 0.5 m height to accommodate the looping type cable end box including excavation and refilling etc. as required. 277 4.5 m but upto 6.5 m 278 6.5 m but upto 8 m 279 supply, erection and installation of strain insulators, post insulators, acsr dog conductor, connectors, shield wire, etc for outdoor switchyard. the job also includes assembling as required, installation on already made concrete foundations or fixing to walls or steel structures or fixtures, aligning, levelling, groutting assembling and fittings all accessories etc. supplied separately, complete in all respects including consumables tools / equipments and labour as per directions of engieer in charge / site engineer. 280 strain insulators for 33 kv 281 acsr dog conductors for 33 kv 282 connectors for 33 kv 283 shield wire for 33 kv 284 post insulators for 33 kv 285 supply and fixing of street light bracket with controlling switch 286 supplying and fixing of 20mm dia. g.i. pipe for street light water tight bracket including bending to shape, 40mm x 3mm flat iron clamps and wiring with 1.5 sq.mm. w.p. / pvc wire alongwith water proof controlling switch and painting the flat iron with primer and finish paint etc. as required. 287 33 kv stay set 288 supplying and erection of galvanised stay set for 33 kv overhead line complete with 19 / 20mm. dia x 1.8 metres long stay road, anchor plate of size 45 mm x 45 cm x 7.5 mm thick thimble, stay clamps, turn buckle ( 20mm x 600mm ) , 7 / 4.00mm. dia g.i. stay wire and 33 kv strain insulator etc. in cement concrete 136 ( 1 cement 3 coarse sand 6 graded stone aggregate 40mm. nominal size ) foundation including excavation and refilling etc. as required. 289 louvers / shutters of exhaust fan 290 fixing of louvers / shutters complete with frame for exhaust fan of all sizes 291 supplying and fixing ceiling fan: supply, installation, testing & commissioning of ceiling fans of bajaj / crompton greaves / khaitan / usha make only including supply and fixing of the electronic regulators with all necessary supports. all complete with labour and material, specification and direction of engineer in charge 292 1200mm sweep ( white ) 293 1400mm sweep ( white ) 294 supplying and fixing wall mounted fan: supply, installation, testing and commissioning of wall mounted fans of bajaj / cromptonreaves / khaitan / usha make only including supply and fixing of the electronic regulators with all necessary supports. all complete with labour and materials as per directions of engineer in charge.. note: necessary civil works required for fixing the exhaust fans shall be in the scope of contractor. 295 osc. wall & cabin fans of 300mm sweep 296 osc. wall & cabin fans of 450mm sweep 297 steel structural works 298 supply, fabrication, erection, installation of steel structural works of any type and shape such as cable raks, cable trays, push button control posts etc., as required job complete in all respects including the cost of all labour, tools, material etc., complete.and as per specifications and directions of site engineer / engineer in charge. 299 flp / wp push button station supply , erection, testing and commissioning of flp / wp push button ( on / off ) control station of approved make with / without ammeter for the motor off control at field including connection and termination of copper control cable, fabricating, earthing the supporting structure, painting the same, including supply & installation of double compression cable glands & flame proof plugs for sealing all spare entries including the cost of all labour, tools, materials etc. complete in every respect as per the specification and directions of the site engineer / engineer in charge including the cost of all labour, tools, materials etc. complete in every respect as per the specification and directions of the site engineer / engineer in charge: 300 with ammeter 301 without ammeter 302 flame proof fittings all equipment under this category shall be suitable ( minimum requirments ) for location in zone i gas group iia & iib ( temp. class t3 ) area with a separate terminal box for incoming cable and a separate terminal box for out going cable ( where applicable ) , apart from separate enclosure for each equipment including control gear etc. in ip 65 cast aluminium lm 6 certified enclosure: 303 flameproof tubelight, 2x22watt, led, suitable for exd gas group ii c, as per is / iec 60079 2007 304 flameproof led well glass fitting 90 w, supply, installation, testing & commissioning of exd ( flameproof ) well glass light fixture with provision of cable entries: 2 nos. x 3 / 4 et, cable glands: 2 nos. x 3 / 4 et ( max. od 20mm ) exd ( iia / iib ) , double compression type, brass nickel plated with pvc hood. blanking plug: 1 no. x 3 / 4 et exd, brass nickel plated. gasket: neoprene, hardware: ss 304, earthing: external 2 nos. ( m6 ) , internal 1 no. ( m5 ) , and as per directions of eic. 305 flameproof led flood light fitting 90 w, supply, installation, testing & commissioning of exd ( flameproof ) flood light fixture with provision of cable entries: 2 nos. x 3 / 4 et, cable glands: 2 nos. x 3 / 4 et ( max. od 20mm ) exd ( iia / iib ) , double compression type, brass nickel plated with pvc hood. blanking plug: 1 no. x 3 / 4 et exd, brass nickel plated. gasket: neoprene, hardware: ss 304, earthing: external 2 nos. ( m6 ) , internal 1 no. ( m5 ) , and as per directions of eic. 306 flameproof led flood light fitting 45 w, supply, installation, testing & commissioning of exd ( flameproof ) flood light fixture with provision of cable entries: 2 nos. x 3 / 4 et, cable glands: 2 nos. x 3 / 4 et ( max. od 20mm ) exd ( iia / iib ) , double compression type, brass nickel plated with pvc hood. blanking plug: 1 no. x 3 / 4 et exd, brass nickel plated. gasket: neoprene, hardware: ss 304, earthing: external 2 nos. ( m6 ) , internal 1 no. ( m5 ) , and as per directions of eic. 307 flameproof led well glass fitting 125 w, supply, installation, testing & commissioning of exd ( flameproof ) well glass light fixture with provision of cable entries: 2 nos. x 3 / 4 et, cable glands: 2 nos. x 3 / 4 et ( max. od 20mm ) exd ( iia / iib ) , double compression type, brass nickel plated with pvc hood. blanking plug: 1 no. x 3 / 4 et exd, brass nickel plated. gasket: neoprene, hardware: ss 304, earthing: external 2 nos. ( m6 ) , internal 1 no. ( m5 ) , and as per directions of eic. 308 critical light: flame proof & weather proof supply, erection ( fixing the same on roof truss, wall, column etc. as required ) , termination of 240v, flame proof light fittings with heat resistant glass diffuser and suitable for led lamp, ip65, of model pel 111 prolite make or equivalent approved makes as per eic. the job includes the cost of fitting and erection 1 no. led lamp 18w, ni cd battery of suitable size for minimum 01 hour back up, battery charger, earthing, supply & erection of all accessories, suitable ms brackets etc. complete. 309 flp & wp junction box supply, erection, installation, testing and commissioning of flameproof & weather proof junction box for providing cable termination of motor, including connection and termination of earthing wire and conduits etc., including supply & installation of double compression cable glands & flame proof plugs for sealing all spare entries complete as per direction of the site engineer, including the cost of all labour, tools, consumable materials etc., complete in all respect: 310 8 way junction box with 8 cable entries ( 1 x 1 & 7 x 3 / 4 ) at bottom & 20 nos. terminals. 311 6 way junction box with 6 cable entries ( 6 x 3 / 4 ) at bottom & 20 nos. terminals. 312 4 way junction box with 4 cable entries ( 4 x 3 / 4 ) at bottom & 20 nos. terminals. 313 exhaust fan supply, installation, testing of single phase 230 v, industrial type heavy duty exhaust fan of gec / usha / crompton greaves or of approved make fitted / provided with louvres, supports etc. including making the required opening on walls, fixing and connecting the wires etc. including earthing the body of the fan, making good the opening on the wall etc. complete as per direction of site engineer including the cost of all labour, tools, materials etc. complete. 314 18 sweep 315 12 sweep 316 flp / wp exhaust fans: 317 flame proof, weather proof, single phase, 12 exhaust fan, ip65, lm6 type ef1001 of fcg or equivalent alongwith supporting frame, bolts, louvers, flame proof motor, including supply & installation of double compression cable glands & flame proof plugs for sealing all spare entries, complete in all respects 318 flame proof, weather proof, single phase, 12 exhaust fan, suitable for exd gas group ii c, as per is / iec 60079 2007, ip65, lm6 type ef1001 of fcg or equivalent alongwith supporting frame, bolts, louvers, flame proof motor, including supply & installation of double compression cable glands & flame proof plugs for sealing all spare entries, complete in all respects 319 flp / wp rotary switch: 320 supply, installation, testing & commissioning of flame proof weather proof on / off rotary switch , ip65, lm6, including including supply & installation of double compression cable glands & flame proof plugs for sealing all spare entries etc., complete in all respects. 321 flp / wp distribution boards supply, erection, installation, testing and commissioning of flameproof / weather proof ( ip 65 ) distribution board as per technical specification of types as per eic for lighting purpose in mlpu / booster shed etc., including connection and termination of power cables, earthing wire and conduits etc. including including supply & installation of double compression cable glands & flame proof plugs for sealing all spare entriescomplete as per direction of the site engineer, including the cost of all labour, tools, consumable materials etc. complete in all respect: 322 outdoor type, floor mounted, flameproof, weatherproof ( ip 65 ) lighting distribution board type i db with bus bar 100 a tpn, incomer 1 no. 63 a tpn mcb & outgoing 9 no. 10 a spn, mcb 323 outdoor type, floor mounted, flameproof, weatherproof ( ip 65 ) lighting distribution board type ii db having bus bar 100 a tpn, incomer 1 no. 32 a tpn mcb & outgoing 3 no. 6 a spn mcb 324 flp / wp switch cum socket supply, erection, installation, testing and commissioning of flameproof / weatherproof switch cum socket / welding receptacle of approved makes to be installed on walls, coloumns, structures, including supply & installation of double compression cable glands & flame proof plugs for sealing all spare entries etc., including connection and termination of earthing wire and conduits., etc. complete as per direction of the site engineer, including the cost of all labour, tools, consumable materials etc. complete in all respect: 325 250v, 15 a switch cum socket with plug 326 250v, 63 a plug & welding receptacle 327 415v, 63a, switch & socket with plug ( no. of pins 3p +n+ e ) , model epss 1563 61 of baliga or equivalent approved make 328 wp 6 way junction box: 329 supply, erection, installation, testing and commissioning of weather proof 6 way junction box of approved make for providing cable termination & including connection and termination of earthing wire and conduits, including supply & installation of cable glands & plugs for sealing all spare entries etc. complete as per direction of the site engineer, including the cost of all labour, tools, consumable materials etc. complete in all respect. 330 wp push button station: 331 supply, erection, testing and commissioning of weather proof push button ( off ) control station of approved make for emergency transformer tripping at field including connection and termination of copper control cable, fabricating, earthing the supporting structure, painting the same, including supply & installation of cable glands & plugs for sealing all spare entries including the cost of all labour , tools, materials etc. complete in every respect as per the specification and directions of the engineer in charge. 332 stainless steel inscription plate : 333 supply and installation of approved quality stainless steel name inscription plates including anodising, engraving the inscriptions, providing screws, etc. for equipments viz. motors, motor control centres, switchgears, push button stations etc. as required, providing necessary holes tapping etc. and fixing the same complete in all respect as per the direction of site engineer / engineer in charge including the cost of all labour, tools etc. 334 plastic inscription plate : 335 supply and installation of approved quality plastic name inscription plates including engraving the inscriptions, providing screws, etc. for equipments viz. motors, motor control centres, switchgears, push button stations etc. as required, providing necessary holes tapping etc. and fixing the same complete in all respect as per the direction of site engineer / engineer in charge including the cost of all labour, tools etc. 336 point wiring supplying, installation and testing with 1.5 sq.mm stranded pvc insulated copper conductor wires for phase & neutral of 650v grade including earthing by providing 1.5 sq.mm earth insulated continutity wire of copper in pvc conduit ( supply & installation of pvc conduit covered elsewhere in sor ) recessed on wall / ceiling / false celing including supply & installation of switch boxes, junction boxes, pull boxes, bushes, screws, check nuts, bends, modular switches and sockets . the circuit wiring with 4 sq.mm pvc copper wire from d.b. to switchboard as required is also in the scope of the contractor: 337 1 light point controlled by 1 switch 338 16 a power plug point wiring: 339 wiring for 250 v single phase and neutral 16 amps modular power plug point with pvc insulated 4 sq. mm. copper conductor wires for phase & neutral, 650 v grade including earthing, the third pin with 2.5 sq. mm copper conductor earthing insulated continuity wire, complete with providing and fixing of 6 pin 16 / 6a modular socket and 20 / 10 a modular switch ( 1 plug point per circuit ) as per directions of site engineer. 340 6 a plug point wiring: 341 wiring for 250 v single phase and neutral 6 amps modular plug point with pvc insulated 2.5 sq. mm. copper conductor wires for phase & neutral, 650 v grade including earthing, the third pin with 1.5 sq. mm copper conductor earthing insulated continuity wire, complete with providing and fixing of 5 pin 6a modular socket and 10 a modular switch ( 1 plug point per circuit ) as per directions of site engineer. 342 ac point wiring: 343 point wiring for power plug point with 4 sq.mm stranded pvc insulated copper wire including earthing the third pin with 2.5 sq. mm copper insulated earthing wire complete with supply and fixing of recessed mounted industrial type 3 pin 32 a metal clad socket and plug, 20a mcb ( motor duty ) housed in a 16 gauge m.s. box 344 lighting distribution board / ac distribution board supply , installation, testing and commissioning of tpn lighting / ac distribution board of approved make, with rating and feeders as per specification. the db shall be of ip 42 protection class and shall conform to is 8623. the board shall be fitted with an acrylic door as per directions of site engineer: 345 type vi light db: euro db dboxx of havells or equivalent make complete with bus bar, neutral links, earth links along with 1 x 6 a mcb spn , 7x2 a spn mcb, digital time switch , 110 240 vac 1 phase 2w, 1 c / o, base / din based upon lat / long setting of location working according sunrise and sunset and mnx 9 2p power contactors 9 a 2 pole 1 no or 1 nc of l&t or equivalent. 346 critical light db: euro db dboxx of havells or equivalent make complete with bus bar, neutral links, earth links and 1 x 6 a mcb spn & 7x2 a spn mcb 347 decorative light fittings supply, installation, connection, earthing and testing of the following fittings, including supply and installation of drop pipes, hooks, fittings, fixtures, nuts, bolts, supports, on walls, outlet box for regulators and all other required materials etc. as per directions of the site engineer including cost of all labour, tools, materials etc. complete in all respects.make of the fittings can be the make mentioned in the respective sor items or equivalent model: 348 tube light fitting type quadra 2 bbs805 2 x llm 1800 / 840 psu e 220v 240v led luminaire of phillips or approved make, complete with all accessories suitable for mounting in false ceiling as per the directions by eic / site engineer. 349 led ceiling point: supply and fixing of surface mounted led ceiling light fitting type mainstream spot aura 15w of phillips or equivalent approved make complete with all accessories such as led module, driver, optics, thermal sink, connector blocks etc including installation. 350 wp endura led: supply and fixing of surface mounted weather proof endura led wt 550 light fitting of phillips or equivalent approved make complete with all accessories such as led module, driver, optics, thermal sink, connector blocks etc including installation. 351 supply and fixing of led wall light cat. no. 35022 9w fitting of phillips or equivalent approved make complete with all accessories such as led module, driver, optics, thermal sink, connector blocks etc including installation. 352 led light fittings, recess mounting type, sereno led rc869b led 30s 6500 pse w30l120 d8 or equivalent approved make with leds: supply and fixing of recess mounted weather proof light sereno led rc869b led 30s 6500 pse w30l120 d8 or equiavlent approved make with leds, 42 w or more, having 2950 lumens or more output. led fitting of phillips or equivalent approved make complete with all accessories such as led module, driver, optics, thermal sink, connector blocks etc including installation with led of approved make. 353 led light fittings with leds, sereno led suspended sp824 p led 30s 5000 gr od or approved equivalent:supply and fixing of surface mounted weather proof light sp824 p led 42 w having 2950 lumens output fitting of phillips or equivalent approved make complete with all accessories such as led module, driver, optics, thermal sink, connector blocks etc including installation with led of approved make. 354 led light fittings, batten with 2xtled tmc501 2x tled 36 w p3242 or equiavlent approved make with leds: supply and fixing of wall mounted / suspended type weather proof light 2xtled tmc501 2x tled or equiavlent approved make with leds, 36 w or more. led fitting of phillips or equivalent approved make complete with all accessories such as led module, driver, optics, thermal sink, connector blocks etc including installation with led of approved make. 355 wt550c led35scwpsu s1 pc: supply and fixing of surface mounted weather proof light wt550c led35scwpsu s1 pc led 42 w having 3500 lumens output fitting of phillips or equivalent approved make complete with all accessories such as led module, driver, optics, thermal sink, connector blocks, etc. including installation. 356 dn170c led10s 6500 psu wh: supply and fixing of surface mounted weather proof light dn170c led 15 w having 1000 lumens output fitting of phillips or equivalent approved make complete with all accessories such as led module, driver, optics, thermal sink, connector blocks etc including installation. 357 critical light: non flame proof type pel 240 m / sl of prolite or of approved make as per eic, with 2 x 18 w led tl / lamp including sealed lead acid battery of suitable size for minimum 01 hour back up, battery charger, for fire fighting pump shed, ht / lt room, battery room etc.the job includes connection of the fitting, 6a switch socket with 2c x 4 sqmm cable from db / switch board and as mentioned above including all accessories etc. complete in all respect as per direction of eic / site engineer. 358 all in one solar based led street light: 359 installation, testing, commissioning charges of all in one solar based led street light including supply of 5 m high gi pole ( with suitable panel mounting arrangement ) and associated civil foundation works complete in all respects. 360 supplying and laying reinforced cement concrete light duty hume pipe, non pressure type ( np3 ) , centrifugally cast conforming to i.s.458 with 1:3:6 concrete casing at joints as required with necessary slope including excavation, backfilling, supply of collars, jointing of pipes with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement: 2 fine sand ) , testing of joints, complete in all respects as per direction of the eic / site engineer: 361 300 mm dia 362 200 mm dia 363 sand filling 364 supplying and spreading of approved quality fine dry river sand in cable trenches including the cost of all material, transport, load and lift charges, labour, tools and tackles, consumables etc , as per directions of site engineer / engineer in charge 365 supply fixing and erection of modular cable transit ( mct ) for cable entry to building in proper frame including supply of peelable type, spare block, stay plates compression wedgs etc. with all accessories considering 20 % minimum spare in each module to be installed as per instruction of engineer in charge / site engineer: 366 galvanised mild steel frame with packing space of min.120x240 mm with multi diameter blocks and accessories with peeling off arrangement to adjust cable size from 3.5mm to 99mm outer dia 367 galvanised mild steel frame with packing space of min.120x180 mm with multi diameter blocks and accessories with peeling off arrangement to adjust cable size from 3.5mm to 99mm outer dia 368 brick soling 369 supply and laying of approved quality 75 mm. thick second class brick flat soling with sand filling in the interestices, in cable trenches for protection of laid cables in all respects including consumables, tools / equipments and labour as per directions of engieer in charge / site engineer. 370 outgoing mccb feeder as per instructions of engineer in charge 371 feeder rating 32a 372 outgoing sfu feeder as per instructions of engineer in charge 373 feeder rating 32 / 32a 374 flood light luminaires with separate c.g. box including cost of lighting fixtures: supply, installation, connection and testing of following flood light luminaries of philips / approved equivalent make with suitable lamps ( lamps cost will be paid separately ) and seperate control gear box ( cg box cost will be paid separately ) on flood light mast, supply and fixing of clamps, supports, nuts, bolts including welding, painting etc. all complete with labour and materials as per directions of engineer in charge. 375 type qvf 135 / 500 w halogen halolite floodlight luminaire 376 type qvf 135 / 70 w mhn td halolite floodlight luminaire including separate cg box 377 control gear box for flood lighting including cost of c.g. box: supply, installation, connection, testing and commissioning of control gear box of philips / approved equivalent make suitable for flood light mast fittings including supply of steel structures / flat / angles and welding, painting etc. all complete with labour and materials as per directions of the engineer in charge. 378 zvx x 300 / 250 / 240, 1x250 w hpi t pressure die cast aluminium cg boxrs with open construction ballasts 379 zvx x 310 / 400 / 240, 1x400 w hpi t pressure die cast aluminium cg boxrs with open construction ballasts 380 zvx 330 / 250 / 240, 1x250 w son pressure die cast aluminium cg boxes with open construction ballasts 381 zvx x 410 / 1000 / 220, 1x1000 w hpi t die cast aluminium cg box 382 zvx x 260 / 70i / 240, 1 x 70 w mhn td pressure die cast aluminium cg boxes with open construction ballasts 383 zvx x 340 / 250 / 240, 1x400 w son pressure die cast aluminium cg boxes with open construction ballasts 384 supply and inst. of c.g. box for flame proof fittings : supply, installation, connecting, testing and commisioning below given flameproof cg box, approved for zone 1 and gas group iia, iib including supply of necessary mounting steel structure / flat / angle and welding, painting etc. all complete with labour and materials as per directions of eic. 385 type flpw 927 ( baliga ) / type cgf 1108 ( crompton ) / 80 w hpmv flameproof cg box approved for zone i to gas group iia, iib 386 supply and inst. of increased safety control gear box : supply, installation, connecting, testing and commisioning below given increase safety cg box, approved for division 2 and gas group iia, iib & iic including supply of necessary mounting steel structure / flat / angle and welding, painting etc. all complete with labour and materials as per directions of eic. 387 type is 30660 ( baliga ) / type cgi 1108m ( crompton ) / 80 w hpmv increased safety cg box approved for division_2 and gas group iia, iib, iic 388 supply of lamps : supply of below given m / s philips or equivalent make lamps for installation in lighting fittings / fixtures as per directions of eic. 389 led bulb 5 6w 390 led bulb 9w 391 led tubelight 18w 392 installation of lighting fixtures ( excluding cost of fixtures ) : fixing of following light fittings attachments on ms hanger / supports / concrete wall structure / steel structure completed with lead in wires and other accessories all complete with labour and materials as per direction of the engineer in charge. ( cost of light fittings / lamp control gears and other fittings shall be excluded ) . 393 flp / increased safety wellglass / bulkhead / tubelight / floodlight 394 flp / increased safety control gear box / junction box / switch / socket 395 recessed tubelight fitting 396 ordinary bulkhead / pl type fitting 397 street light fitting ( upto 9 m height ) 398 street light fitting ( more than 9 m height ) 399 floodlight without control gear 400 control box for floodlight 401 floodlight without control gear ( more than 9 m height including on fldm ) 402 control box for floodlight ( more than 9 m height including on fldm ) 403 overhauling of window ac, split ac, water cooler etc. 404 overhauling and painting of wac, sac, wc & cold storage of different make & different capacities located at various location within the iocl premises. job includes removal of machines from location , dismantling , cleaning , washing , chemical cleaning of condenser & cooling coil , overhauling , lubrication of blower motor , checking , repair / rectification / replacement of effective control component. painting of all metal part and chassis cover internal painting with primer & outer painting with synthetic enamel paint. cleaning of coil & condenser to be done with wire brush. defective / damage insulation to be replaced. all the electrical wires must be dressed properly. defective wires to be replaced including supply of wires. defective / damage asbestos sheet to be replaced. asbestos sheet shall be provided by the owner. cleaning / replacement of filter by nylon filter.reassembly of machine, shifting to location & testing of machine. job complete in all respect including men & material and as per direction and instruction of site engineer / engineer in charge. 405 monthly routine maintenance of window ac, split ac, water coolers etc. 406 routine, regular and breakdown maintenance of wac, sac, wc and cold storage of different make & different capacities installed at various location of iocl premises . job includes attending the complaints of machines as per the complaint register and instruction of site engineer. job includes checking of machines, identification of defect, repair / replacement of defective component. rewinding of blower motor. replacement of thermostat, blower, fan blade, electrical switches, control knob, wires. cleaning of air filter, removal of dust from cooling coil & condenser by removing the machine from location if required. attending the minor / major leakage of refrigerant gas r 22 / r 12 arresting the leak and recharging the gas. repair / replacement of defective bush / bearing of blower motor including lubrication of blower motor, tightening of all the electrical connection. repair / replacement ( by repaired compressor ) of defective compressor. job includes dismantling of defective compressor either at site or at workshop after transportation of machine to workshop, taking necessary gate pass / permission from concerned 407 installation of split ac 408 transportation, installation, testing & commission of 2.0 / 3.0 tr split ac of any indian make. job includes supply and providing copper tube upto 4.0 meter, insulation of copper tube, refrigerant gas r 22 charging, supply & fixing required electrical wire. job complete in all respect as per direction of site engineer / engineer in charge. 409 additional copper tube for split ac 410 supply & fixing of additional length of copper tube for split a / c commissioning including all accessories. 411 replacement of burnt uncut compressor 412 replacement of burnt uncut compressor of 1.5 ton capacity from the manufacturer whenever required as per direction of engineer in charge. 413 replacement of burnt uncut compressor of 1.0 ton capacity from the manufacturer whenever required as per direction of engineer in charge. 414 gas charging of air conditioner 415 gas charging of air conditioner upto 1.5 ton capacity with job involved transportation of machine to vendors works. checking of all components for leak by charging co2 gas & finally evacuating the compressor completely & charges of refrigerant gas 22. a 416 electrical service items 417 cable laying laying of all type of cables lt ( pvc / xlpe / armoured / unarmoured / power / control / signalling ) in trenches, in cable racks, in trays, in protective pipes, poles, columns, in conduits, in panels and on structures etc.; including the supply and installation of all required materials such as fixing clamps, screws, cable straps, tags, etc. as required ( other than the supply of the conduits, cables, pipes, cable racks, trays, poles, structures and panels ) complete in all respect, including cost of all labour, tools, consumable materials, etc. and cutting the cables in required lengths as per directions of site engineer / engineer in charge: 418 power cables lt : od upto 20 mm 419 power cables lt : od above 20 mm and upto 40 mm 420 power cables lt : od above 40 mm and upto 60 mm 421 power cables lt : od above 60 mm 422 power control cables lt : od upto 20 mm 423 cable laying laying of all type of cables lt ( pvc / xlpe / armoured / unarmoured / power / control / signalling ) in trenches, in cable racks, in trays, in protective pipes, poles, columns, in conduits, in panels and on structures etc.; including the supply and installation of all required materials such as fixing clamps, screws, cable straps, tags, etc. as required ( other than the supply of the conduits, cables, pipes, cable racks, trays, poles, structures and panels ) complete in all respect, including cost of all labour, tools, consumable materials, etc. and cutting the cables in required lengths as per directions of site engineer / engineer in charge: 424 power cables ht 425 removal of rubbish / debris / brickbats 426 removal of rubbish / debris / brickbats, laterite boulders, earth, plaster flakes etc. including carriage by mechanical transport including packing stacking the rubbish in regular stacks at loading points at different places before loading the same in the trucks and unloading the same at directed places upto a lead of 2 km, including local carriage of rubbish at loading and unloading point etc. complete as per direction of the engineer in charge. ( payment will be made by stack measurement after deducting 20% for voids from stack measurement ) . 427 painting of electrical equipments 428 cleaning of surface, rust removing of foreign matter, rubbing down thoroughly with emery paper, wire brush, washing with degreasing solvent ( white spirit ) to remove grease etc. and preparation of surface for application of enamel paint by spray painting on bus ducts, transformers / motors / or any other metallic surface with one coat of ready mixed primer and two coats of approved quality / apcolite asian synthetic enamel paint including supply of paint suitable for a temperature of 100 degree celsius. all complete with labour and materials as per directions of the engineer incharge. 429 cleaning of surface, rust removing of foreign matter, rubbing down thoroughly with emery paper, wire brush, washing with degreasing solvent ( white spirit ) to remove grease etc. and preparation of surface for application of paint by spray painting on electrical equipment / structures / poles or any other metallic surface with two coats of approved brand & manufacturer of aluminium paint including supply of paint suitable for a temperature of 100 degree celsius. all complete with labour and materials as per directions of the engineer in charge. 430 lettering 431 lettering with black japan paint of approved brand and manufacture note : unit of measurement is considered each which is equal to per cm height per letter. 432 ht cable disconnection: disconnection of ht cables of following sizes at one end and reconnecting it at same place or another place after dressing and cleaning the terminals all complete with labour and materials as per the direction of the the engineer incharge 433 overall diameter upto 35 mm 434 overall diameter > 35 mm but upto 55 mm 435 overall diameter >55 mm but upto 75 mm 436 overall diameter > 75 mm 437 lt cable disconnection: disconnection of lt cables of following sizes at one end and reconnecting it at same place or another place after dressing and cleaning the terminals all complete with labour and materials as per the direction of the the engineer in charge. 438 overall diameter upto 35 mm 439 overall diameter > 35 mm but upto 55 mm 440 overall diameter >55 mm but upto 75 mm 441 overall diameter > 75 mm 442 temporary laying and dismantling of cables: temporary laying and dismantling of following cables ( armoured / unarmoured, power / control / telecommunication / computer ) of different voltage grades / sizes / types for temoprary connections during shutdown etc., including transportation of cable from stores / another site and returning the same after dismantling to store, all complete with labour and materials as per directions of the engineer incharge. 443 overall diameter upto 35 mm 444 overall diameter > 35 mm but upto 55 mm 445 overall diameter >55 mm but upto 75 mm 446 overall diameter > 75 mm 447 cleaning of light fitting fixtures: cleaning of below given fitting fixtures alongwith perfex cover ( wherever applicable ) with the help of surf powder. it includes the removal of perfex cover, washing the lighting fixture with powder, cleaning with fresh water and clothes and refixing in the same position. it also includes arranging ladder as and wherever required, providing scaffolding at all heights with necessary tools & tackles. all complete with labour and materials as per directions of the engineer incharge. 448 tube light fitting / ceiling / exhaust fan / fan at any height inside a building. 449 mll / hpmv / hpsv lamp of flp / increased safety / weather proof or any other similar fittings upto 250 w 450 lt panel cleaning 451 cleaning of complete pcc / mcc panels. it includes opening of side top covers, removal of dust by vacuum cleaners / blowers etc., checking and tightening of screws, nuts, bolts, washers & connections, application of petroleum jelly and boxing up of the panels. all complete with labour and materials as per directions of the engineer in charge. 452 earth resistance measurement 453 measurement of earthing resistance in thepump station / rcp / cp / ( other pipeline installation ) including transportation of earthing electrodes, cables etc. from stores to site, drawing the same into the ground at different points for measuring the earth resistance. the job includes the supply of connecting leads, clamps etc. all complete with labour and materials as per directions of the engineer in charge. note measuring instruments to be supplied by the owner 454 transformer cleaning 455 cleaning of transformer includes surface cleaning i.e. cleaning of accumulated sticky oil and other dust, oil fins. job includes opening of lt duct & ht terminal box, cleaning of duct and terminal box, tightening of nuts & bolts wherever is required. job to be completed with all men, materials and equipments like tools & tackles as per direction and satisfaction of the engineer in charge. all cleaning materials such as markin cloth, cotton waste etc. shall be supplied by the contractor. 456 ht / lt motor cleaning: cleaning of ht / lt motors & its push button includes cleaning of accumulated oil / spilage oil & other particles on the surface of motor & connected cable & surrounding area of the motor. all cleaning material such as cotton waste, markin cloth etc. shall be supplied by the contractor. job to be completed with all man & material as per direction & entire satisfaction of the engineer in charge. 457 ht motors 458 lt motors less than 45 kw 459 lt motors 45 kw & above 460 fixing of electrical components 461 fixing, fitting, commissioning, assembly of loose supplied components, if any, and connecting of one no. switch fuse unit / automate / starter of rating upto 400 a , 3 phase, 415 v with on without relay in normal / explosion proof enclosure, existing / new distribution panel or in control panel, mounted on wall / floor etc. transportation of automate / starter / switch fuse unit from the store to the site ( maximum distance of 10 km ) . job complete in all respect with labour and as per thedirection of engineer in charge excluding supply of switch fuse unit / automate / starter. 462 cable trench: 463 excavation in unpaved ares of earth in the work sites for cables trenches for a depth upto 1.5 meters including shoring, strutting etc. ( if necessary ) , backfilling the trench after cable laying with excavated earth or sand within the work sites complete in all respects including consumables, tools / equipments and labour. the work shall be performed as per directions of engineer in charge / site engineer. 464 lightning arrestor : erection, installation, testing & commissioning of lightning arrestors with insulating base, discharge counter, fittings etc. including assembling as required, installation on already made steel structures or fixtures, aligning, levelling, grouting, assembling and fitting of accessories / instruments etc. supplied separately, if any, making of the conductor connection, cables connections as required, earthing, testing, commissioning the same, complete in all respects including consumables, tools / equipments and labour as per directions of engineer in charge / site engineer. the supply of earthing strip is not covered in this item. 465 for 60 kv rated voltage ( highest system voltage 72.5 kv ) , 10 ka lightening arrestors 466 for 30 kv rated voltage ( highest system voltage 36 kv ) , 10 ka lightening arrestors 467 brick work in cable trench: removal of bricks from cable trench without any damage to the cable and disposing it within a lead of 50 meteres or stacking it at the edge of the trench and putting it back into the same trench or in a new cable trench within a lead of 50 meteres after the work is completed including completing the work in allrespects with all labour and materials as per the direction of the engineerin charge. 468 removal and relaying 469 removal and stacking only 470 removal of sand from cable trench 471 removal of sand from cable trench without any damage to the cable and disposing it within a lead of 50 meteres or putting it back into the same trench or in a new cable trench within a lead of 50 meteres all complete with labour and materials as per the direction of the engineer incharge. 472 removal of rcc slab upto 150 mm thick 473 removal of rcc slab upto 150 mm thick and of any size placed above the cable trench, handling carefully without any damage of the slab and cable beneath it and keeping it back in position after laying / removing the cable and sealing the same between rcc covers with cement & sand. job complete in all respect with labours and materials and as per direction of engineer in charge. 474 cable dismantling / pull out: dismantling / pulling out the lt / ht, pvc / xlpe, power / control / telephone / computer, armoured / unarmoured cables of various voltage grades / types / sizes / makes from the trench ( upto 1.5 metres deep ) / pipes / structures / racks or trays, rolling it into empty cable drums, returning the filled up cable drums to the store / another site including transportation of empty cable drums from stores to site and filled up cable drums from site to stores / another site, etc. including cutting of cables at joints / termination, dismantling of clamps etc. all complete with labour and materials as per directions of the engineer incharge. 475 overall diameter upto 35 mm 476 overall diameter > 35 mm but upto 55 mm 477 overall diameter >55 mm but upto 75 mm 478 overall diameter > 75 mm 479 cable dismantling / pull out and relaying: dismantling / pulling out the lt / ht, pvc / xlpe, power / control / telephone / computer, armoured / unarmoured cables of various voltage grades / types / sizes / makes from the trench ( upto 1.5 metres deep ) / pipes / structures / racks or trays and relaying as per direction of engineerin charge, all complete with labour and materials. job includes declamping, rerouting and relaying of cable for reglanding etc. 480 overall diameter upto 35 mm 481 overall diameter > 35 mm but upto 55 mm 482 overall diameter >55 mm but upto 75 mm 483 overall diameter > 75 mm 484 dismantling of power distribution equipments: dismantling of following power distribution equipments without any damage to it and returning it to our stores or reinstallation of same at a place within a lead of 3 km ( reinstallation charges not includes ) all complete with labour and materials as per the direction of the eic. 485 small equipment requiring tractor trailer but not requiring crane / hydra etc. ( beyond 100 kg. ) 486 equipment weighing above 500 kg and requiring hydra and tractor trolley etc. 487 equipment weighing more than 3 mt and requiring crane and tractor trolley etc 488 attending complaints : attending and rectification of complaint of the following note: all materials & accessories of fittings required for attending the complaint shall be supplied by the owner free of cost. the contractor has to take the material from central store / departmental store / site in charge. for attending above complaints. the defective material are to be returned to the deptt. stores. consumables items like pvc tape, cleaning tape, cleaning cloth, ctc etc. are in the scope of contractor. also application of pvc / m seal on above fittings to above entering of water / insects as per direction of the engineer in_charge. 489 tube light fittings including replacement of chokes, tubes, down rods, starters, starter holder, tube rod and holders and all other accessories if needed including cleaning of the light fittings if required. all complete with labour and materials as per direction of the engineer in charge 490 flp / increased safety and weatherproof upto 250 w lamps including replacement of lamps, lamp holders, connectors, glass & other accessories etc. including external and internal cleaning of glass and complete fittings as well as other related job involved. all complete with labour and materials as per directions of engineer in charge. 491 control gear boxes of hpmv lamp fittings upto 250w including replacement of chokes, condensers, fuses, holders, fuse base, wiring or any other accessories of control gear box. all complete with labour and materials as per directions of the engineer in charge. 492 fldms / highway fittings / street light fittings including replacement of lamps, tubes, ignitors, chokes, capacitors, fuses, fuse holders, gasket, providing / extension rod on lamp holder glass including cleaning of glass or any other accessories required. all complete with labour and materials as per directions of the engineer in charge. 493 circuit fault rectification 494 rectification of circuit fault in flp / non flp junction boxes / djbs / dbs / switchboards etc. other than in fldms including supply of minor type of materials costing less than rs.6.00 in one complaint. all complete with labour and materials as per directions of the engineer in charge. note : materials used by contractor should not exceed rs.6.00 per complaint. balance material exceeding rs. 6.00 per complaint shall be supplied by owner free of cost. also application of pvc putty / m seal putty on above fittings, if required, to avoid entering of water / insects as per directions of the engineer in charge. putty will be supplied by owner free of cost. 495 miscellaneous complaints 496 attending complaint of installation e.g. hand lamps, flood lights, exhaust fans, halogen fittings, smoking booth & other elect. complaints & replacement of crocodile clips on earthing leads with a maximum period of one hour from the time of receipt of complaint. 497 cleaning of cable trenches 498 cleaning of cable trenches of depth upto 3 meter and width 1.5 meter of cable galleries, sub stations and other locations etc. the job includes lifting of rcc slabs / chequerred plates, removing of paper waste jute, mud, or any other unwanted materials lying in trenches & dumping these waste materials in the nearest dust bin or as directed by the engineer in charge., keeping back rcc slabs / chequerred plates in positions. all complete with men and materials as per direction of the engineer in charge. 499 horizontal drilling 500 making horizontal bore / drill for roads at different location. job includes pipe coupling & cutting, insert the pipe through both side of the road and make it as original ( gi pipe, ms pipe from 2 to 8 meter long ) ( horizontal drilling ) . gi / ms pipe supply shall be in the scope of iocl. transportation of the pipe from stores / site to work site shall be in the scope of the contractor. 501 replacement of old transformer oil 502 replacement of the old oil from the transformer as per the specifications given below a ) old oil heating by hot oil circulator for 4 hrs. b ) draining out entire quantity of oil. c ) blanking of all opening for vaccum pulling. d ) applying vacuum pulling for 4 hrs minimum 600 hg mercury pressure. e ) filtration of new transformer oil for filling. f ) filling the oil under vacuum & filtration of oil till desired bdv is attained as per is. g ) releasing all the air from air release plug & bucholz relay h ) topping up of oil. i ) to and fro transportation of filter machine and equipments. j ) transportation of old and new oil. 503 wbm road / concrete breaking: 504 wbm road / concrete breaking for cable trenches including required shoring strutting etc., and repairing of the road / dyke to original condition and disposing off excess materials ( within the work site ) job complete in all respects including the cost of labour, tools, materials, load, lift hire charges of equipments, if any, complete as per directions of site engineer / engineer in charge. 505 excavation in hard rock : 506 excavations in hard rock requiring chiselling for cable trenches upto depth of 1.5 metres, including shoring, strutting ( if necessary ) , excavated earth or sand to be back filled ( after cable laying ) to the finished level and excess earth to be disposed off within the work sites complete in all respects including comsumables, tools / equipments and labour. the work shall be performed as per directions of engineer in charge / site engineer. 507 itc of ceiling fan and regulator with aluminium connecting cable 508 installation, testing and commissioning of ceiling fan and regulator including wiring the down rod of standard length ( upto 30 cm ) with 1.5 sqmm, pvc insulated, aluminium conductor, single core cable etc. as required. 509 installation of exhaust fan:fixing of exhaust fans on existing opening, complete with lead in wires and other accessories all complete with labour and materials as per direction of the engineer in charge. ( cost of fans shall be excluded ) 510 with louver shutter / mesh 511 without louver shutter / mesh 512 flp / is exhaust fan 513 dismantling of split ac 514 dismantling , shifting of 2.0 / 3.0 tr split ac including dismantling of all the copper tube, condensing unit, electrical connection to new location or a / c workshop as per direction of site engineer / engineer in charge. 515 electrical supply items 516 shock treatment chart 517 supply of shock treatment chart in glass frame suitable for wall mounting 518 safety equipment supplying the following safety equipment as per directions of site engineer / engineer in charge complete in all respects including transportation charges: 519 supply and installation of 33 kv discharge rod 520 supply of hand gloves 521 suitable for 11 / 33 kv voltage level with isi mark and with test certificate with issue date within 1 month 522 supply of elastomer mat 523 supply of 2000mm x1000 mm, 3 mm thick ( class b ) elastomer mats conforming to is: 15652:2006 524 insulating elastomer mats conforming to is 15652:2006 of thickness 2.5 mm ( class b ) 525 extra for providing copper lugs: supply ( to be used only when it is mentioned in sor that lug supply is excluded ) of copper tube terminal heavy duty ( crimping cable lug ) of kse / dowells make or equivalent certified by eic. of the following sizes. 526 1.5 sqm 527 2.5 sqm 528 4.0 sqm 529 6.0 sqm 530 10.0 sqm 531 16.0 sqm 532 25 sqmm 533 extra for providing aluminium lugs: supply ( to be used only when it is mentioned in sor that lug supply is excluded ) of aluminium tube terminal heavy duty ( crimping cable lug ) of kse / dowells make or equivalent certified by eic. of the following sizes. 534 16.0 sqm 535 25 sqmm 536 35 sqm 537 50 sqm 538 70 sqm 539 120 sqm 540 150 sqmm 541 240 sqmm 542 300 sqmm 543 extra for providing flameproof double compression ( brass ) cable glands: supply ( to be used only when it is mentioned in sor that gland supply is excluded ) of cmrs / cce approved flameproof double compression ( brass ) cable gland for following overall cable sizes as per directions of engineer in charge. 544 10.0 to 16.0 mm 545 16.5 to 18.0 mm 546 18.5 to 20.0 mm 547 20.5 to 23.0 mm 548 23.5 to 26.0 mm 549 26.5 to 30.0 mm 550 30.5 to 33.0 mm 551 33.5 to 37.0 mm 552 37.5 to 41.0 mm 553 41.5 to 46.0 mm 554 46.5 to 52.0 mm 555 52.5 to 60.0 mm 556 60.5 to 66.0 mm 557 lightning arrestor : supply of lightning arrestors with insulating base fittings etc. as per specifications 558 for 60 kv rated voltage ( highest system voltage 72.5 kv ) , 10 ka lightening arrestors 559 for 30 kv rated voltage ( highest system voltage 36 kv ) , 10 ka lightening arrestors 560 supply of materials / equipments as given below complete in all respects, as per the instruction of eic including transportation to site and storing : 561 supply of zn grounding cells ( with prepackaged backfill material ) including required length of cable ( minimum 10 m ) of approved make & as per instructions of eic. 562 dcdb 563 installation and commissioning of wall mounted dcdb including supply of all cable end lugs, cable glands, fittings & fixtures and all other required accessories, tools and tackles complete in all respects as per directions of site engineer / engineer in charge. item includes supply and termination of 2 runs of 1cx25 sq. mm copper cable for battery bank 564 ht 33 kv, 11 kv & 6.6 kv cables screened, xlpe insulated, extruded pvc type st 2 inner sheathed, galvaznized armoured, pvc type st 2 overall sheathed, stranded, frlsh, c2, smoke density<40% 565 al 3cx120 mm² 6.6kv 566 al 3c x 150 mm² 6.6 kv 567 al 3cx185 mm² 6.6kv 568 al 3cx240 mm² 6.6 kv 569 al 3cx400 mm² 6.6kv 570 al 3cx400 mm² 33kv 571 lt cables frlsh aluminium cables 1.1 kv, xlpe insulated, extruded pvc type st 2 inner sheathed, galvanized armoured, pvc type st 2 overall sheathed, stranded, frlsh, c2, smoke density<40% 572 al, 3cx10 mm², a2xfy 573 al, 3cx16 mm² 574 al, 4cx16 mm², a2xfy 575 al, 3cx25 mm², a2xfy 576 al, 3.5cx25 mm², a2xfy 577 al, 4cx25 mm², a2xfy 578 al 3c x 35 mm² 579 al, 3.5cx35mm², a2xfy 580 al, 3cx50mm² 581 al, 3.5cx50 mm², a2xfy 582 al, 3½c x 95 mm² 583 al, 3½c x 120 mm² 584 al, 3.5cx150 mm², a2xfy 585 al, 3c x 185 mm² 586 al, 3½c x 185 mm² 587 al, 3.5cx240 mm², a2xfy 588 al, 3.5cx400 mm², a2xfy 589 supply of xlpe insulated , pvc sheathed cable, 1100 v grade conforming to is: 7098 ( p 1 ) as per specifications and approved make 590 copper cable size 1cx50 sq. mm armoured 591 copper cable size 1cx35 sq. mm armoured 592 copper cable size 1cx25 sq.mm armoured 593 copper cable size 2cx6 sq.mm armoured 594 copper cable size 2cx25 sq.mm armoured 595 copper cable size 2cx70 sq.mm armoured 596 tinned copper cable size 1cx10 sq.mm unarmoured for distributed anodes of station cp system 597 civil items 598 providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement all work up to plinth level : 1:2:4 [ 1 cement : 2 coarse sand derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources ] 599 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level :thermo mechanically treated bars of grade fe 500d or more 600 brick work with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 in foundation and plinth in : cement mortar 1:4 ( 1 cement : 4 coarse sand ) 601 random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 ( 1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size ) at window sills, ceiling level and the like. 602 12mm plaster ( in coarse sand ) :1:4 ( 1 cement : 4 coarse sand ) 603 casting, supplying and erecting in position precast reinforced cement concrete elements ( with proper lifting lugs ) for trench & drain covers, shelves, partitions, post, slabs etc. for all leads and levels including making necessary moulds, vibrating, tamping, curing, finishing the top surface with cement mortar 1:3 ( 1 cement : 3 fine sand ) to give a smooth and even surface, transportation to site, aligning and fixing in position with cement mortar 1:3 ( 1 cement: 3 find sand, ) including making recess in brick wall for placing the precast element in position and making good the same etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per directions of the engineer in charge. [ note: payment for reinforcement shall be made as per relevant item of sor. ] :with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 10 mm nominal size ) . 604 motor items 605 rewinding of lt motor upto & incl 11 kw as per special conditions of contract ( technical ) of tender document 606 rewinding of lt motor 12 18 kw as per special conditions of contract ( technical ) of tender document 607 rewinding of lt motor 132 150 kw as per special conditions of contract ( technical ) of tender document 608 overhauling of lt motor upto & incl 11 kw as per special conditions of contract ( technical ) of tender document 609 overhauling of lt motor 12 15 kw as per special conditions of contract ( technical ) of tender document 610 overhauling of lt motor 132 260 kw as per special conditions of contract ( technical ) of tender document 611 shaft metallizing / repair of lt motor upto & incl 11 kw as per special conditions of contract ( technical ) of tender document 612 shaft metallizing / repair of lt motor 12 15 kw as per special conditions of contract ( technical ) of tender document 613 shaft metallizing / repair of lt motor 16 21 kw as per special conditions of contract ( technical ) of tender document 614 shaft metallizing / repair of lt motor 111 150 kw as per special conditions of contract ( technical ) of tender document 615 dynamic balancing of lt motor upto & incl 11 kw as per special conditions of contract ( technical ) of tender document 616 dynamic balancing of lt motor 12 15 kw as per special conditions of contract ( technical ) of tender document 617 dynamic balancing of lt motor 111 150 kw as per special conditions of contract ( technical ) of tender document 618 supply terminal plate of lt motor upto & incl 11 kw as per special conditions of contract ( technical ) of tender document 619 supply terminal plate of lt motor 12 18 kw as per special conditions of contract ( technical ) of tender document 620 supply terminal plate of lt motor 111 150 kw as per special conditions of contract ( technical ) of tender document 621 supply of cooling fan lt motor upto & incl 11 kw as per special conditions of contract ( technical ) of tender document 622 supply of cooling fan lt motor 12 18 kw as per special conditions of contract ( technical ) of tender document 623 supply of cooling fan lt motor 111 150 kw as per special conditions of contract ( technical ) of tender document 624 supply of fan cover lt motor upto & incl 11 kw as per special conditions of contract ( technical ) of tender document 625 supply of fan cover lt motor 12 18 kw as per special conditions of contract ( technical ) of tender document 626 supply of fan cover lt motor 111 150 kw as per special conditions of contract ( technical ) of tender document 627 supply of end shield lt motor upto & incl 11 kw as per special conditions of contract ( technical ) of tender document 628 supply of end shield lt motor 12 15 kw as per special conditions of contract ( technical ) of tender document 629 supply of end shield lt motor 111 150 kw as per special conditions of contract ( technical ) of tender document 630 suply of bearing cover lt motor upto & incl 11 kw as per special conditions of contract ( technical ) of tender document 631 suply of bearing cover lt motor 12 18 kw as per special conditions of contract ( technical ) of tender document 632 suply of bearing cover lt motor 111 150 kw as per special conditions of contract ( technical ) of tender document 633 erection, testing and commissioning of motor on existing foundation including carriage from stores to the site, unpacking, placing on foundation, levelling, fixing and fitting of all components, making necessary connections, phase checking, meggering as necessary all complete with labour and materials as per the direction of engineer in charge. small equipment requiring tractor trailer but not requiring crane / hydra etc. ( beyond 100 kg. ) 634 erection, testing and commissioning of motor on existing foundation including carriage from stores to the site, unpacking, placing on foundation, levelling, fixing and fitting of all components, making necessary connections, phase checking, meggering as necessary all complete with labour and materials as per the direction of engineer in charge. equipment, panels, motor etc. weighing above 500 kg and requiring hydra and tractor trolley etc.but <3mt 635 erection, testing and commissioning of motor on existing foundation including carriage from stores to the site, unpacking, placing on foundation, levelling, fixing and fitting of all components, making necessary connections, phase checking, meggering as necessary all complete with labour and materials as per the direction of engineer in charge. equipment, panels, motor etc.weighing more than 3 mt and requiring crane and tractor trolley but <25mt 636 supply and installation of l&t / siemenas or equilent make dol motor starter ( with all acessaries including o / l relay etc. ) confirming to is:13947 4 on walls / steel structure, connection of cables all complete with labour and materials as per direction of the engineer in charge upto 5.5kw 637 supply and installation of l&t / siemenas or equilent make dol motor starter ( with all acessaries including o / l relay etc. ) confirming to is:13947 4 on walls / steel structure, connection of cables all complete with labour and materials as per direction of the engineer in charge 5.5 to 7.5 kw 638 supply and installation of l&t / siemenas or equilent make dol motor starter ( with all acessaries including o / l relay etc. ) confirming to is:13947 4 on walls / steel structure, connection of cables all complete with labour and materials as per direction of the engineer in charge 7.5 to 11kw 639 supply and installation of l&t / siemenas or equilent make dol motor starter ( with all acessaries including o / l relay etc. ) confirming to is:13947 4 on walls / steel structure, connection of cables all complete with labour and materials as per direction of the engineer in charge 11 to 15kw 640 transportation of lt induction motor for rewinding frompump station to contractors works and back to pump station. this includes arranging suitable vehicle for to & fro transportation, unloading & loading the motor at rewinding works. all complete with labour, materials, tools and tackles as per the direction of engineer in charge.note: lifting facility to put the motor in the vehicle at our end will be provided by iocl for the motors of capacity more than 15 kw. motor upto 1.5 kw 641 transportation of lt induction motor for rewinding frompump station to contractors works and back to pump station. this includes arranging suitable vehicle for to & fro transportation, unloading & loading the motor at rewinding works. all complete with labour, materials, tools and tackles as per the direction of engineer in charge.note: lifting facility to put the motor in the vehicle at our end will be provided by iocl for the motors of capacity more than 15 kw. motor above 1.5 kw to 18.5 kw 642 transportation of lt induction motor for rewinding frompump station to contractors works and back to pump station. this includes arranging suitable vehicle for to & fro transportation, unloading & loading the motor at rewinding works. all complete with labour, materials, tools and tackles as per the direction of engineer in charge.note: lifting facility to put the motor in the vehicle at our end will be provided by iocl for the motors of capacity more than 15 kw. motor above 75 kw to 160 kw 643 online condition monitoring and diagnostic testing of 6.6 kv ht motors as per tender specifications 644 offline condition monitoring and diagnostic testing of 6.6 kv ht motors as per tender specifications 645 offline diagnostic testing of ht cables as per tender specifications 646 fixed charges for transportation of equipments, mobilisation of engineers & instruments, accomodation arrangement by contractor itself during work at site, lodging and boarding etc. for carrying out work at erpl patna pump station....

Department Of Science And Technology - Bihar

34039969 bids are invited for lab equipments as per list 01 a trainer kit for half wave rectifier with resistive load 02 a trainer kit for full wave rectifier with r load and r i, load free whiling diode 03 a trainer kit for r and rc triggering kit for scr 04 a trainer kit for scr, v i characteristics 05 a trainer kit for functioning of power transistor 06 a trainer kit for function of igbt 07 a trainer kit for determining the firing angle using diac and triac under different load 08 a trainer kit for functioning of diac to determine the break over voltage 09 10 a trainer kit for wi triggering technique of variation of r.0 earth tester testing voltage ( 220v ) display 3. v: digit lcd 11 a trainer kit for kelvin double bridge for measurement of low resistance 12 single phase energy meter 13 stop watch 14 megger 15 a trainer kit for clamp on meter 16 watt meter 17 single watt meter. digital watt meter, f=501 1z voltage 220v 18 two wattmeter range 0 — 200w. 0 200f2w 19 dc ammeter 20 dc volt meter 21 variable resistance ( q3 ) total quantity : 1...

Eastern Railways - Bihar

33568775 supply of ransformer, 230 volt ac, 1 phase, 50 hzransformer, 230 volt ac, 1 phase, 50 hz,transformer, 230 volt ac, 1 phase, 50 hz, output 110v for 110 v dc generation with contactor (30amp/240v/2pole), regulator (high and low voltage accuracy), digital ammeter (100v, dc+/ a ac 70 a), volt meter (50a, 230 vac a1+v1), mcb (240, 500v, 50/60 hz) hrc protected fuse ( 330 uf/16v), diode (100v/10 amp), cable (2 mm) with fitment cost. => limited...

Department Of School And Mass Education - Bihar

31449505 bids are invited for lab item 1 , lab item 2 , lab item 3 , lab item 4 , lab item 5 , lab item 6 , lab item 7 , lab item 8 , lab item 9 , lab item 10 , lab item 11 , lab item 12 , lab item 13 , lab item 14 , lab item 15 , lab item 16 , lab item 17 , lab item 18 , lab item 19 , lab item 20 , lab item 21 , lab item 22 , lab item23 , lab item 24 , lab item 25 , lab item 26 , lab item 27 , lab item 28 , lab item 29 , lab item 30 , lab item 31 , labitem 32 , lab item 33 , lab item 34 , lab item 35 , lab item36 , lab item 37 , lab item 38 , lab item 39 , lab item 40 total quantity : 117 1 vernier caliper 2 screw gauge 3 travelling microscope 4 tripod base with levelling screws, height stand, measuring tape, sextant, astronomical telescope, terrestrial telescope 5 fly wheel set up ( the setup should consists of flywheel ( 200 mm diameter ) with axle supported on bearings 2. hanger 100 g + 9 × 100 g slotted weights 3. stop watch 4. vernier calliper 5. meter scale 6. thread 7. instruction manual ) 6 moment of inertia setup ( moment of inertia table setup should consists of 1. micro controller based measurement unit. 2. engraved and ruled inertia discs. 3. inverted ushaped metal body with chuck screw connection. 4. measurement unit giving instant result of moment of inertia. 5. three experimental bodies. 6. for time measurement of rotation, measurement unit with manual and automatic mode. ) 7 photoelectric effect setup ( the setup consists of main unit having highly stabilized power supply, digital volmeter ( led 3 digit , 0 9.99vdc ) , digital micro ammeter ( led 3 digit , 0 999uadc ) , digital milliammeter ( led , 3 digit , 0999madc ) light source ( 3 colours –white , blue, red ) black box with spacers for distance variation. ) 8 p n junction kit 9 pnp / npn transistor kit 10 mosfet kit 11 cro, function generator ( equipment and technical data · frequency range: 0.1 hz to 1 mhz · steps: 0.1 hz · distortion factor: <0.5% · signal forms: sine, triangle, square, frequency ramp, voltage ramp · amplifier output, short circuit proof, via bnc and 4 mm connectors: o output voltage : 0 20 vpp for r out > 40 ohm o dc offset: ±10 v ( steps 5 mv ) o power output: 5 w ( for up to 1a ) where r out = 20 ohm · headphone output via 3.5 mm jack socket:o switch for selecting standard o output voltage: 0 1 vpp for r out =400 ohm. ) 12 he ne laser source and diffraction grating setup ( he ne laser source · output power: 0.5 mw – 5 mw · wavelength: 632.8nm · polarized or randomly polarized output · tem00 mode · beam divergence: <1.0 mrad · beam diameter: ≤ 0.7mm 2. power supply ( input 240 v / 50 hz ) 3. optical bench ( 1.5 meter ) 4. reflection grating ( 15000 lines per inch ) 5. transmission grating ( 15000 lines per inch ) 6. photo detector with bnc connector and holder 7. screen ( 12 x 12 ) with clamp type holder 8. knife edge with micrometer movement 9. digital multimeters 10. scale with mount ) 13 optical fiber setup ( the setup consists of laser diode ( 5mw, 632mm ) , objective ( 10x ) , fiber ( 1mtr long ) , dectector with bnc connector autoarranging multimeter, chucks and bases ( 2nos ) to hold the components, screen with circular graduations, one circular base with linear and circular motion and optical bench.headphones or speakers ) 14 forced oscillator and resonance set up ( it should consists of base unit with frequency generator ( mass attached to spring which is connected to a cord passing over a pully and further connected to drive wheel ) , spring of known spring constant, scale attached to setup, weight 50g four each. ) 15 a nearly monochromatic source of light ( source of sodium light ) , a plano convex lens c, an optically plane glass plate p, an optically flat glass plate g in clined at an angle of 45◦, a travelling microscope with measuring scale and a spherometer. ( newtons ring apparatus dimension: 390 x 480 x 170mm approx. micrometer: 0.01 mm least count eyepiece: ramsden 10x objective: 3x weight: 12.6 kg approx. spherometer type: 3 legs verticale scale: 6mmx6mm ( wxt ) micrometer: dia. 40mm, brass lower disc: dia. 60mm range: 10 0 10mm least count: 0.01mm plano convex lens dia. : 61.5mm, glass focal length : 200mm ) 16 dc power supply in following parts: ( a ) h.t. ( high tension ) dc power supply ( b ) dc power supply for solenoid ( c ) potentiometers ( d ) two meters to measure acceleration voltage &solenoid current ( e ) eight pin octal bases, one long solenoid , crt mounted inside the solenoid. ( 1.dc power supply for apparatus comprises of the following built in parts: ( a ) h.t. ( high tension ) dc power supply continuously variable from 375v to 850v±5% for acceleration voltage control. ( b ) dc power supply for solenoid 0 60vdc variable in steps through two band switches ( 5 steps ) using fine and coarse controls band switches. ( c ) potentiometers are mounted on the front panel for focus control, intensity control and x, y shift controls. ( d ) two meters to measure acceleration voltage &solenoid current are mounted on the front panel. ( e ) eight pin octal bases are mounted on the front panel to connect the crt plug. 2.one long solenoid wound on 4 ̋dia pvc with 23 wire gauge, mounted on wooden stand & connections brought out at terminals. 3.crt mounted inside the solenoid. ) 17 capacitance and permittivity setup ( the setup consists of reed relay switch with it’s a.c. supply, integrated circuit current amplifier and 0 100 micrometer housed in a cabinet.pair of capacitor plates 0.25m x 0.25m x 4 mm, a perspex sheet, two capacitors ( 500 pf each ) , and set of perspex / polythene spacers ) 18 dielectric constant measurement set up ( the setup should consists of 1. digital voltmeter ( 0 99 vac ) @ 1khz 2. audio oscillator ( 1khz ) 3. standard capacitors ( 2 nos ) ( in pf and nf range ) 4. gold plated parallel plate dielectric cell i ( 75mm ) 5. gold plated parallel plate dielectric cell ii ( 25 mm ) 6. dielectric sample for dielectric cell i ( glass – 2 nos, bakellite 1 no, pcb 1 no ) 7. dielectric sample for dielectric cell ii ( pzt 2 nos, barium titanate 1 no 25 mm diameter with 8. instruction manual complete unit should be housed in metal cabinet of 416x230x165mm with effective electromagnetic shielding with proper connecting cables. ) 19 forced oscillator and resonance set up ( it should consists of base unit with frequency generator ( mass attached to spring which is connected to a cord passing over a pully and further connected to drive wheel ) , spring of known spring constant, scale attached to setup, weight 50g four each. ) refrective index setup ( the set up should consist of spectrometer, diffraction grating, mercury light source, prism, reading lens etc. spectrometer standard: 7 diacircle reading 30 seconds. the used in telescope and collimator has to be achromatic and provided with rack and pinion focusing arrangement telescope arm and prism table are to be provided with fine and coarse adjustment. the prism table is provided with three 20 leveling screws and is engraved with concentric rings & lines. the scales and verniers are of stainless steel ) 21 he ne laser source and diffraction grating setup ( he ne laser source · output power: 0.5 mw – 5 mw · wavelength: 632.8nm · polarized or randomly polarized output · tem00 mode · beam divergence: <1.0 mrad · beam diameter: ≤ 0.7mm 2. power supply ( input 240 v / 50 hz ) 3. optical bench ( 1.5 meter ) 4. reflection grating ( 15000 lines per inch ) 5. transmission grating ( 15000 lines per inch ) 6. photo detector with bnc connector and holder 7. screen ( 12 x 12 ) with clamp type holder 8. knife edge with micrometer movement 9. digital multimeters 10. scale with mount ) 22 optical fiber setup ( the setup consists of laser diode ( 5mw, 632mm ) , objective ( 10x ) , fiber ( 1mtr long ) , dectector with bnc connector autoarranging multimeter, chucks and bases ( 2nos ) to hold the components, screen with circular graduations, one circular base with linear and circular motion and optical bench. ) 23 friction table and horizental board ( one big table with clamp and horizental board ) 24 searles apparatus with weight box. ( for different weight measure ) 25 terminal velocity measure stocks law set up ( glycerin stop watch bob, tube clamp stand 26 pullingers apparatus ( heet burner tripod stand, weeker tube iron rode etc. ) 27 fortins barometer 28 mercury thermameter ( mercury thermameter 0 to 360 c, 300mm long ) 29 ultrasonic interfero meter ( measuring device for velocity of ultra sonic ) 30 plane mirror interface 31 glass slab ( 75 x 50 x 18 mm and glass prism ( 50 x 50 ) ) 32 convex lens ( 2 convex x 50mm ) 33 ohms law apparatus ( p=1.5wp volt 220v i 250 ma ) 34 post office box ( different resistence measure ) 35 kirchoffs law verification kit ( electrical curcit ) 36 capaciter and kits 37 galvanometer ( curcit ( dc ) 30 30v ) 38 ammeter 39 volt meter 40 optical projection system ( ohp / lcd for project report ) ...

Indian Oil Corporation Limited - Bihar

30441059 bso engg providing sewage treatment plant ( stp ) , water treatment equipment and supply pumps for our new green office building of bihar state office patna stp & water treatment equipment and supply pump 2 section 1 : sewage treatment plant 3 mbbr based ( moving bed bio reactor follwed by ultrafiltration ) 4 design, supplying, installing, testing & commissioning of sewagetreatment plant of45 kld 5 the contractors scope of work shall also include following: 6 process flow sheet 7 hydraulic profile 8 layout of plant room within given space ( refer attached drawing ) . 9 basic and detailed drawings of structures. 10 equipment, piping, and electrical specifications. 11 piping and electrical & instrumentation drawings. 12 preparation of project report for submission to pollution controlboard and statutory authority and obtaining approvals. 13 all civil works ( including ga and rcc details ) as per of civil scope. [ civil work will be in scope of civil contractor ] 14 fabrication required in plant. 15 supply and installation of all electro mechanicals as per the scope. 16 erection and commissioning of plant. 17 performance guarantee & warrantees. 18 training of employer’s personnel for operation of the plant. 19 manual on operation and maintenance of the plant. 20 operation and maintenance of stp for two years after successful commissioning of the plant. 21 inlet sewage characterstics 22 flow rate 45 kl / day 23 ph 6.0 – 8.5 24 bod 250 350 mg / l 25 s. solids 200 300 mg / l 26 cod 400 600 mg / l 27 oil & grease 15 20 mg / l 28 tkn 35 40 mg / l 29 phospate 10 mg / l 30 note: plant should be able to operate at lower range of above parameters. 31 effluent discharge standard after treatment 32 ph 6.0 – 7.5 33 bod less than 10 mg / l 34 s. solids less than or equal to 20 mg / l 35 cod less than or equal to 50 mg / l 36 oil & grease less than or equal to 1 mg / l 37 turbidity less than 1 ntu 38 total nitrogen less than 10 mg / l as n 39 total phosphorous less than 2 mg / l as pcb 40 note: ensuring that the above parameters are within the statutory compliance limit is the responsibility of the stp contractor. 41 sewage treatment plant shall include the following stp tanks: 42 screen chamber 43 oil & grease chamber 44 equalization tank / sump 45 anoxic tank 46 mbbr tank ( 2 no. ) 47 tube settler tank 48 filter feed tank 49 clear water tank ( primary treated water ) 50 flushing water tank 51 sludge holding tank 52 soft water tank 53 sludge holding tank 54 note: contractor shall ensure submission of detailed ga drawings ( plan & section ) , p & i diagram, schematic diagram for the mentioned component in soq and additional component if so required for the complete working of the stp and got it approved by the owner’s architect / project manager / consultants. 55 tanks in civil are tentative and that need to be varified by the vendor before quoting and after comming on the board it shall be stp vendors resposibility any changes required at site and shall be in done by stp contractor. location, size and dimesional detail shall be provided by the stp vendor in the shop drawing. 56 all manhole covers shall be double seal medium duty ci alongwith frame and lockable arrangement and shall be in scope of civil contractor. location and other relevant details of the same shall be provided by the stp vendor in the shop drawing. 57 the sewage treatment plant shall comprise of following: 58 pretreatment devices and plant accessories 59 supply, installation, testing & commissioning of 300 mm x 600 mm high stainless steel construction coarse screen ( including one standby ) with lifting arrangement.the perforation in the screen shall be 8 mm. 60 supply of ms hot dip galvanized puddle flanges in accordance to bs:10 table d as required to be provided ( in the structural slab and wall ) of various diameters. puddle flanges shall be provided for all the structural component of the stp. the installation of the puddle flanges shall be carried out by the civil contractor in accordance to the civil ga drawing ( to be prepared by the stp contractor ) at the required levels& position; under the supervision of the stp contractor 61 supply of plastic step / foot rest ( @ 300 mm c / c ) with polypropelene compound injection molded around 12 mm dia ( fe 415 ) steel reinforcing bar. provision of the foot rest is envisaged in various tanks / components of the stp for the purpose of accessability. the installation of the foot rest shall be done by the civil contractor as per civil ga drawing 62 supply, installation, testing & commissioning of cilight duty / msep rectangular manhole cover with frame for the feasibility of access in the tank 63 size : 600 x 900 weight as per mfg. stds. 64 supply of vent pipes of 100 mm dia vent pipe with mosquito proof grating for treated water tank suitable for the ventilation purpose of the various tanks 65 supply, installation, testing & commissioning of electronic type level controller for automatic operation of the system with high / low level alarm complete with auxillary no / nc contacts for ( to be provided for all the tanks and plant room sump ) 66 supply, installation, testing & commissioning of sight tube ( of 3.5 to 4.5 m length ) with isolation valve at top / bottom, demarcation on tube & for making the installation complete for treated water tanks. 67 supply of submersible mixer for mixing in anoxic tank: 68 moc: pp / ss blades with ci / ss casing 69 mechanical equipment: pumps, blowers etc. 70 supply, installation, testing & commissioning of non clogging type pumps capable of handling solids upto 35 mm having ci casing & ci impeller complete with all accessories, motor of required capacity. delivery header with isolation valve, pressure gauge on delivery line with isolation cock, level controller as per item no. 1.7 along with control panel ( with wiring ) to control the level of sump automatically. pumpsshall have following duty: the provsion of local push button near the pumps should be considered. 71 submersible sewage pumps ( non cutter type ) for transfer of raw sewage in eqt ( 1 working & 1 standby ) : 72 flow rate ( each ) = 3 m3 / hr 73 head =8 10m 74 solid handling size for this pump = 20mm 75 submersible sewage pumps ( non cutter type ) for transfer of stp plant room sump tank ( 1 working + 1 standby ) 76 flow rate ( each ) = 3.0 m3 / hr 77 head =12 15 m 78 solid handling size for this pump = 20 mm 79 cost shall be inclusive of pvcflexible hose pipe ( for piping submreged in effluent ) with pvc / gipiping ( for piping non submerged in effluent ) 80 provision of guide ropes to guide submersible pump from upper level to operational level in sump basin with channels / angle section shall be made by the stp contractor. ( if required ) 81 air diffusionsystemshall include the following: 82 air blower for equilisation , sludge tank & aeration tank : air blowers of suitable hp suitable for 415 ± 10% volts, 3 phase, 50 cycles a / c supply. numbers & capacity as per requirement with standby to be specified by vendor. capacity: 100 m3 / hr @ 0.4 kg / cm2 qty ( 1w+1s ) 83 air piping shall comprise of pvc pipedroppers / laterals with gi header complete with all fittings such as valves, nrv, strainer, tees, crosses, plugs, sockets, elbows, reducers, supports & clamps, puddle flanges etc. contactor to submit detailed p & i indicating their proposal. 84 non clog, self cleaning type air dispersion system capable of handling 3 5 cfm of air with oxygen transfer efficiency of3 4% per / meter water depth. air dispersion grid shall be assembled in modular form so that they can be replaced / repaired easily from plat form at the top. ( imported fine bubble membrane diffusers ) . 85 supply, installation, testing & commissioning of mbbr media consisting of virgin pe / pp carrier modules with surface not less than 400 m2 / m3. the media qty. shall be calculated based on 6 12 gm / m2 area. also supply and fixing of tube deck media of reputed make with suitable quantity. the surface area of tube deck shall be 11 m2 / m3 and the quantity will be based on max 2.0 m / h velocity. 86 note: contractor shall consider the media as required for the stp and include in his quote. 87 bronze ball valve and air dispersion grid as required for stp as described above. 88 note : air dispersion system shall be provided for equalization tank, anoxic tank, mbbr tanks and sludge holding tank. 89 providing and fixing all piping ( as described below ) and isolation control valves for making the system complete. 90 ms: exposed air pipe, frontal pipe for vessels 91 upvc piping: waste water pipe, submerged pipe, interconnecting pipe line afterdelivery header of pumps, tank overflow pipe etc. 92 providing, fixing, testing and commissioning of single stage, horizontal, centrifugal, 2 pole, 50 hz, ac, monoblock pumps ( as per is : 9079 ) incorporating c.i. casing and frame, stainless steel shaft, bronze / ss impeller, tefc induction motor directly coupled to the pump, ip44 protection, class b insulated, c.i. body, hydraulically and dynamically balanced to give vibration free operation, with mechanical seal arrangement, fixed on a base plate with suitable vibration eliminator pads complete with level controller, pressure switch , necessary wiring / cabling ( from tank to pumps & panel ) , pressure gauge, valves, vibration eliminators on the delivery side and strainer on suction side, including non return valve and isolating valves on suction and delivering sides as required, including suction, delivery headers and interconnecting piping ( upvc ) complete in all respects. 93 capacity : 6.0 m3 / h 94 head : 30 35 m 95 rpm : 2900 96 ( 1 working + 1 standby ) 97 ( filter feed pumps ) 98 capacity : 5.0 m3 / h 99 head : 70 m 100 rpm : 2900 101 ( 1 working + 1 standby ) 102 ( flushing water transfer pumps ) 103 capacity : 7 m3 / h 104 head : 35 m 105 rpm : 2900 106 ( 1 working + 1 standby ) 107 ( softner feed pumps ) 108 capacity : 10.0 m3 / h 109 head : 70 m 110 rpm : 2900 111 ( 1 working + 1 standby ) 112 ( soft water transfer pumps ) 113 capacity : 3.0 m3 / h 114 head : 25 30 m 115 rpm : 2900 116 ( 1 working + 1 standby ) 117 ( irrigation pumps ) 118 supplying, installation, testing and commissioning of horizontal centrifugal sludge recirculation pumps for tank coupled with motor of capacity 3.375 m3 / h at 6 to 8 m head of c.i. parts and mechanical seal complete with isolation and non return valves. ( 1 working + 1 standby ) 119 supply, installation, testing & commissioning of vertical self supporting multigrade sand filter in frp / grp construction ( the filter shall be designed for a tested presure of min. 5.5 kg / cm2 ) pressuregaugesatinlet&outlet, sample cock, upvc / cpvc face piping, automatic mpv along with prvision for manual multiport valve andallaccessories, withinitialchargeoffiltermediafor multigrade & activated carbon filter, testing and commissioning complete 120 multi grade filter 121 capacity / flow rate:6.0 m3 / hr 122 design velocity:15 m / hr 123 operating pressure :3.0 to 3.5 kg / sq.cm 124 test pressure:5.5 kg / sq.cm 125 suggested dia meter : 700mm ø 126 moc: frp / grp ( filament winded ) 127 activated carbon filter 128 capacity / flow rate:6.0 m3 / hr 129 design velocity:15 m / hr 130 operating pressure :3.0 kg / sq.cm 131 test pressure:5.5 kg / sq.cm 132 suggested dia meter : 700mm ø 133 activated carbon :i / vshould be 600 134 moc: frp / grp ( filament winded ) 135 softener 136 supply, installation, testing and commissioning of water softening plant. the water softener vessel in frp / grp construction ( the filter shall be designed for a tested presure of min. 5.5 kg / cm2 ) pressuregaugesatinlet&outlet, sample cock, upvc / cpvc face piping, automatic mpv along with prvision for manual multiport valve andallaccessories, withinitialchargeofion exchange resin. the inner distribution system and the under bed draw off system shall be of hub & lateral type with top & bottom strainers of . softener shall be supplied with initial charge resin with supporting media like silex, gravel etc. outlet fitting complete along with regeneration assembly comprising of ejector, brine suction valve and all associated pipe work. 137 the brine tank shall be provided with salt saturation arrangement including suitable hdpe brine tank of300 liters / as per design capacity complete including piping, cpvc / upvc valves and accessories of required size. 138 softener size: 139 flow rate : 7 m3 / hr 140 input hardness considered 600 ppm ( considered ) 141 output hardness less than 50 ppm 142 moc frp / grp ( filament winded ) 143 obr 50 kl 144 operating pressure 3.0 kg / sq.cm 145 test pressure 5.5 kg / sq.cm 146 size: 700 mm dia x 1800 mm hos with 500 liters resin 147 supplying, installing, testing and commissioning of dosing system consisting of one hdpe tank of 100 litres capacity with a positive displacement diaphragm dosing pump having variable flowrate of 0 6 lph. the motor shall be suitable for operation at 240 v / single phase / 50 hz. supply. the pump shall be supplied complete with necessary polypropylene piping, valves, strainers, low level switch andinjection fittings. the pump shall be speed & stroke control. 148 providing, installing, testing and commissioning ofskid mounted ultra filtration ( uf ) system for further polishing treated effluent and capable of producing 8 m3 / hour of polished water meeting the requirements. the system shall be complete with uf feed pumps ( 1w+1s ) , backwash cum cip pumps ( 1w+1s ) , cartridge filter, uf membranes flushing / cleaning system, complete instrumentation for automation and monitoring, rotameters, pressure gauges, interconnecting pipework, electrical cabling and switchgear, all complete as described in scope of work enclosed herewith.note: the process and the control system of ultra filtration ( uf ) package shall be in complete conformity of the uf membrane manufacturer. the complete system of ultra filtration including its skid, mmembrane, piping, pumps, automation valves must be factory assembled by the approved system makes only. 149 supplying, installing, testing & commissioning of ultravoilet dis infection unit. the unit shall have over 99.9 % bacterial reduction from inlet to outlet. the dis infection chamber shall be constructed of ss 316l on all welted parts. the uv lamp shall be of low pressure mercury vapour type with hard glass enclosure, the sockets shall be water tight & vibration resistant. the lamp life shall be rated for 6000 hours. the unit shall be complete with temperature safety control, lamp out alert circuit & uv radiometer with 4 – 20 ma output. 150 the uv unit shall have with reactor, cabinet housing, cabinet cooling, treatment chamber, electrical panel, temperature safety control, lampout alert and uv monitoring readout panel.the uv dosage should be > 60, 000 uw – sec / sq.cm. the lamps should be selected based upon the flow requirement of respective unit. 151 flow rate : 3 m3 / hour [ at outlet of irrigation water transfer pumps ] 152 flow rate : 5 m3 / hour [ at outlet of flushing water transfer pumps ] 153 flow rate : 10 m3 / hour [ at outlet of soft water transfer pumps ] 154 supply , installation , testing and commissioning of hydraulic filter press of size 12 x 12 with 7 no of plates with 1 set ( 1 working + 1 standby ) of screw pumps to feed to filter press as per the complete set as per the vender specification 155 supply of microprocessor based electo magnetic flow meter for total plant capacity of 45 kld with pulsed dc excitation having automatic zero correction with bi directional flow measurement , compact instrument version with measuring sensor ( primary ) and amplifier integrated in one mechanical unit ( suitable for required flow range, inlet / outlet connections, ip 67 protection, measuring pipe material ss 304, electrode material ss 316 with 16 character x 2 lines lcd alphanumeric display for flow rate, totalizer, diagnostic message, flow alarms with high & low flow programmable throught the range. ) with all accessories for inlet flow measurement before screen chamber. 156 supply, installation, testing & commissioning of digital turbine type water meter with sensor for treated water monitoring 157 flow rate : 3 m3 / hour [ at outlet of irrigation water transfer pumps ] 158 flow rate : 5 m3 / hour [ at outlet of flushing water transfer pumps ] 159 flow rate : 10 m3 / hour [ at outlet of soft water transfer pumps ] 160 approval from pollution board including consent to operate at initial & various other stages of works including preparation of report / drawings as per pollution board requirement, arrangement of raw sewage. contractor shall include the cost of all chemicals consumed and the cost of such items of works which are not explicitly mentioned above, but are mandatory to have pollution board approval. 161 bypass arrangement from equalization tank to municipal sewer includingfittings, isolation valves / nrv / accessories within the plant room at the discharge of the sewahe bye pass pump upto discharge header. 162 providing & fixing of online monitoring system comprising of following : 163 measuring range: as required 164 method: uv / visible different optical absorption spectroscopy, wave length range 200 800 nm. 165 technology : uv visible spectroscopy 166 sample flow: 0 5 lpm 167 power: 230v ac, 30 w 168 range ( cod ) : 0~5~200 mg / l 169 interval: 60 sec 170 probe depth: < 10 m 171 working temp: 5 deg cel ~ 45 deg cel 172 auto cleaning: yes 173 probe weight: 5 kg 174 power supply: 12 24vdc ( + / 10% ) 175 sample temperature: plus 2…..........plus 40 deg cel 176 ambient temperature: plus 2…..........plus 40 deg cel 177 inflow velocity:0.1 10 m / s 178 mild steel fabrication works for various sections like operating platforms, stairs & ladders, base frame of tube settler media ( including frp / resin coat ) supporting strcutures within the stp plant room required for the stp piping supports / cable tray supports. all ms fabricated structures must be properly painted with epoxy or rubber coats for corrotion protection after having put 2 coats of redoxide primer. 179 electrical installation for stp 180 design, fabrication, assembling, wiring, supply, installation, testing and commissioning of motor control center fabricated out of 14 gauge crca sheet steel. cable gland plates shall be provided on top as well as at the bottom of the panels. panels shall be treated with all anticorrosive process before painting as per specifications with 2 coats of red oxide primer and final approved shade of powder coated paint. 2 nos. earthing terminals shall be provided for 3 phase, 4 wire, 50 hz supply system. lifting hooks shall also be provided in case of large panels. approval shall be taken for each panel before fabrication. quoted rates shall be inclusive of cables, ( in accordance to cable trays specification ) with earthing from panel to each motor / equipment. 181 motor control centre : 182 incoming 183 63 amps tpn mccb with the following accessories: 184 0 500 volts 96 x 96 mm square electronic voltmeter with selector switch shall be protected by2 amps tp mcb.1 set 185 0 60 amps 96 x 96 mm square electronic ammeter with selector switch and 100. / 5 amps 10 va cl:1 cts. 1 set 186 phase indicating lamps shall be protected by 2 amp sp mcb 3 sets 187 1 set of on / off indication lamps 188 bus bar 189 100 amps tpn aluminum bus bar with heat shrinkable insulation sleeves. 190 outgoing 191 a. 2 nos. suitable rating mpcb for 0.75 kw dol starter and outgoing feeder to raw sewage transfer pumps motor ( including 1nos. standby ) .each compartment shall contain auto / manual selector swtich and indicating / pushbutton lamps with mcb for on / off / trip of motor. 192 b. 2 nos. suitable rating mpcb for 0.75 kw dol starter and outgoing feeder to plant room sump pumps motor ( including 1nos. standby ) .each compartment shall contain auto / manual selector swtich and indicating / pushbutton lamps with mcb for on / off / trip of motor. 193 c. 2 nos. suitable rating mpcb for 3.75 kw direct on line starterand outgoing feeder to air blowers ( including 1 no. standby ) . each compartment shall contain auto / manual selector switch andindicating lamps with mcb’s for ‘on / off / trip status of motor. 194 d. 2 nos. suitable rating mpcb for 0.375 kw direct on line starter and outgoing feeders to sludge recirculation pumps ( including 1 no. standby ) . compartment shall contain auto / manual selector switch andindicating lamps with mcb’s for‘on / off / trip’ status of motor. 195 e. 2 nos. suitable rating mpcb fornos. 1.1 kw direct on line starter and outgoing feeders to filter feed pumps ( including 1 no. standby ) . each compartment shall contain auto / manual selector switch and indicating lamps with mcb for ‘on / off / trip’ status of motor. 196 f. 2 nos. suitable rating mpcb fornos. 1.1 kw direct on line starter and outgoing feeders to softener feed pumps ( including 1 no. standby ) . each compartment shall contain auto / manual selector switch and indicating lamps with mcb for ‘on / off / trip’ status of motor. 197 g. 2 nos. suitable rating mpcb fornos. 1.1 kw direct on line starter and outgoing feeders to uf feed pumps ( including 1 no. standby ) . each compartment shall contain auto / manual selector switch and indicating lamps with mcb for ‘on / off / trip’ status of motor. 198 h. 2 nos. suitable rating mpcb fornos. 2.2 kw direct on line starter and outgoing feeders to uf backwasg cum cip pumps ( including 1 no. standby ) . each compartment shall contain auto / manual selector switch and indicating lamps with mcb for ‘on / off / trip’ status of motor. 199 i.2 nos. suitable rating mpcb fornos. 1.1 kw direct on line starter and outgoing feeders to irrigation water transfer pump ( including 1 no. standby ) . each compartment shall contain auto / manual selector switch and indicating lamps with mcb for ‘on / off / trip’ status of motor 200 j.2 nos. suitable rating mpcb fornos. 2.2 kw direct on line starter and outgoing feeders to flushing water transfer pump ( including 1 no. standby ) . each compartment shall contain auto / manual selector switch and indicating lamps with mcb for ‘on / off / trip’ status of motor 201 k.2 nos. suitable rating mpcb fornos. 3.0 kw direct on line starter and outgoing feeders to soft water transfer pump ( including 1 no. standby ) . each compartment shall contain auto / manual selector switch and indicating lamps with mcb for ‘on / off / trip’ status of motor 202 l.2 nos. suitable rating mpcb fornos. 0.75 kw direct on line starter and outgoing feeders to screw pumps ( including 1 no. standby ) . each compartment shall contain auto / manual selector switch and indicating lamps with mcb for ‘on / off / trip’ status of motor 203 m. supply for dosing pumps, uvs, necessary cable alleys, internal / cabling, wiring, cabling from mcc to various pumps / equipment and interlocking, gi cable trays earthing for all equipment shall also included. 204 all mccbs / mcbs shall be of 25 kabreaking capacity and suitable for motor duty application. 205 all motor starters shall be provided with automatic level controller. 206 provision shall be made for providing potential free contacts to all pumps starters 207 note: ratings of all starters may vary as per actual selection of equipment & should be approved by consultant before manufacturing 208 mcc – 1 for stp as described above 209 section 2 : water treatement equipment & supply pumps 210 providing, fixing, testing and commissioning of single stage, horizontal, centrifugal, 2 pole, 50 hz, ac, monoblock pumps ( as per is : 9079 ) incorporating c.i. casing and frame, stainless steel shaft, bronze / ss impeller, tefc induction motor directly coupled to the pump, ip44 protection, class b insulated, c.i. body, hydraulically and dynamically balanced to give vibration free operation, with mechanical seal arrangement, fixed on a base plate with suitable vibration eliminator pads complete with level controller, pressure switch , necessary wiring / cabling ( from tank to pumps & panel ) , pressure gauge, valves, vibration eliminators on the delivery side and strainer on suction side, including non return valve and isolating valves on suction and delivering sides as required, including suction, delivery headers and interconnecting piping ( g.i. heavy class ) complete in all respects. 211 capacity : 7.5 m3 / h 212 head : 70 m 213 rpm : 2900 214 ( 1 working + 1 standby ) 215 ( domesticwater transfer pumps ) 216 submersiable pump 217 supply, installation, testing and commissioning of continuous duty submersible centrifugal non clogging drainage pumps complete with 3 phase motor with all necessary protection and mechanical seal etc. complete with all ancillaries including float type level controllers, electrical control panels fabricatd from 14 gauge crca sheet volt meter ammeter with selector switch, tpmcb, 5 va cl : cts, phase indicating lamps protected by 2 amp sp mcb, dol starter, necessary wiring, cable alleys, earthing, interlocking, starter with automatic float type level controller, providion of high level alarm, sequence timer, potential free contact to starter for connection to bas, both pumps may run simultaneously at pre determind level. the submersible sump pump shall be provided with guide wire for lifting and lowering pump, m.s. galvanized lifting chain, duck foot bend. ( 1working + 1standby ) 218 vendor to submit proposed pump model with duty curve. 219 flow rate: 15 lps each 220 head: 15 20 mts 221 solid handling : 30 40 mm 222 location : basment 223 purpose : drainage basment 224 moc:ss body ss impeller & shaft 225 flow rate: 10 lps each 226 head: 15 20 mts 227 solid handling : 20 30 mm 228 location : basment 229 purpose :plant room 230 moc:ss body ss impeller & shaft 231 flow rate: 2 lps with cutterpump 232 head: 15 20 mts 233 location : basment 234 purpose : basement toilet sewage pump 235 moc:ci body bronze impeller & shaft 236 providing, fixing, testing and commissioning of single stage, horizontal, centrifugal, 2 pole, 50 hz, ac, monoblockpumps ( as per is : 9079 ) incorporating c.i. casing and frame, stainless steel shaft, bronze / ss impeller, tefc induction motor directly coupled to the pump, ip44 protection, class b insulated, c.i. body, hydraulically and dynamically balanced to give vibration free operation, with mechanical seal arrangement, fixed on a base plate with suitable vibration eliminator pads complete with level controller, necessary wiring ( from tank to pumps & panel ) , pressure gauge on the delivery side and strainer on suction side, including non return valve and isolating valves on suction and delivering sides as required, including suction and delivery headers complete in all respects. 237 filter feed pump ( 1 working + 1 standby ) 238 flow rate ( each ) =3.75 m3 / hr 239 head =30 35 m 240 purpose : raw to domestic 241 location : plumbing plant room 242 filter feed pump ( 1 working + 1 standby ) 243 flow rate ( each ) =3.75 m3 / hr 244 head =30 35 m 245 purpose : rain waterto raw 246 location : plumbing plant room 247 supply, installation & testing and commissioning of vertical floor mounted filterof suitable size, provided with an inlet distributor. the vessel material of m.s with frp lining / epoxy coating with g.i. frontal piping , inter connection, suction & delivery header and valves ( c.i. ) , back wash system & filter media etc. complete with standard fittings like access cover, pressure gauge at inlet & outlet, sampling cock, rinse drain valve, air vent valve with piping, bolts, nuts & rubber gaskets. 248 note: all the frontal piping, valves and their fitting should be designed on 1.5m / s velocity 249 multi grade filter 250 capacity / flow rate:3.75 m3 / hr 251 filteration rate : 18000 l / sqm / hr 252 operating pressure :3.0 kg / sq.cm 253 test pressure:5.5 kg / sq.cm 254 purpose : raw to domestic 255 moc m.s. with frp linning 256 activated carbon filter 257 capacity / flow rate:3.75 m3 / hr 258 filteration rate : 15000 l / sqm / hr 259 operating pressure :3.0 kg / sq.cm 260 test pressure:5.5 kg / sq.cm 261 purpose : raw to domestic 262 moc m.s. with frp linning 263 multi grade filter 264 capacity / flow rate:3.75 m3 / hr 265 filteration rate : 18000 l / sqm / hr 266 operating pressure :3.0 kg / sq.cm 267 test pressure:5.5 kg / sq.cm 268 purpose : rain waterto domestic 269 moc m.s. with frp linning 270 softener 271 supply, installation, testing and commissioning of water softening plant. the water softener vessel shall be constructed of m.s material with epoxy coating. the inner distribution system and the under bed draw off system shall be of hub & lateral type / riser tube with top & bottom strainers of . softener shall be supplied with initial charge resin with supporting media like silex, gravel etc. the softener shall be complete with pressure gauge at inlet & outlet, sample cock, g.i face piping / interconnected piping, multiport valve ( control valve ) . overflow & drain, outlet fitting complete regeneration assembly comprising of power valve, ejector, brine suction valve and all associated pipe work. a density meter for brine shall be included. 272 salt saturation arrangement: 273 the brine tank shall be provided with salt saturation arrangement including suitable hdpe brine tank of 2 regeneration capacity complete with resins of approved quality and make complete with bypass arrangement including piping, ci valves ( 3 nos. ) and accessories of required size. 274 plant sizes: 275 capacity / flow rate 3.75 m3 / hr 276 input hardness considered 600 ppm ( considered ) 277 output hardness less than 150 ppm 278 moc ms with epoxy 279 obr 30 kl 280 operating pressure 3.0 kg / sq.cm 281 purpose : rain waterto domestic 282 test pressure 5.5 kg / sq.cm 283 supplying, installing, testing and commissioning of dosing system ( for domestic water treatment plant ) consisting of one hdpe tank of 100 litres capacity with a positive displacement diaphragm dosing pump having variable flowrate of 0 6 lph. the motor shall be suitable for operation at 240 v / single phase / 50 hz. supply. the pump shall be supplied complete with necessary polypropylene piping, valves, strainers, low level switch andinjection fittings. the pump shall be speed & stroke control. 284 electrical installation 285 fabrication, wiring, supply of motor control centre shall be fabricated out of 14 gauge crca sheet steel in form in 3b formation with reinforcement of suitable size angle iron, channel ‘t’ sections irons and / or flats wherever necessary. cable gland plates shall be provided on top as well as at the bottom of the panels. panels shall be treated with all anticorrosive process before painting as per specifications with 2 coats of red oxide primer and final approved shade of powder coated paint. 2 nos. earthing terminals shall be provided for 3 phase, 4 wire, 50 hz supply system. lifting hooks shall also be provided in case of large panels. approval shall be taken for each panel before fabrication. cadmium plated hardware shall be used in fabrication of panels. quoted rates shall inclusive of cables, cable trays, control cabling, earthing ( in accordance to specification ) with earthing from panel to each motor / equipment. 286 mcc –1 for plumbing system 287 incoming 288 100 amps tpn mccb with the following accessories: 289 a. 0 500 volts 96 x 96 mm squarevoltmeter with selector switch protected by2 amps tp mcb. 1 set 290 b. 0 100 amps 96 x 96 mm square ammeter with selector switch and 160 / 5 amps 10 va cl:1 cts. 1 set 291 c. phase indicating lamps protected by 2 amp sp mcb 3 set 292 bus bar 293 160 amps tpn ( 25 ka ) aluminium bus bar with heat shrinkable insulation sleeves. 294 outgoings 295 a.2 nos. suitable rating mpcb fornos. 3.0kw direct on line starter and outgoing feeders to domestic watertranfer pump ( including 1 no. standby ) . each compartment shall contain auto / manual selector switch and indicating lamps with mcb for ‘on / off / trip’ status of motor 296 b. 2 nos. suitable rating mpcb for 1.5 kw dol starter and outgoing feeder to filter feed pump motor ( including 1 nos. standby ) .each compartment shall contain vaf meter, auto / manual selector swtich and indicating / pushbutton lamps with mcb for on / off / trip of motor. ( raw to domestic ) 297 c. 2 nos. suitable rating mpcb for 1.5 kw dol starter and outgoing feeder to filter feed pump motor ( including 1 nos. standby ) .each compartment shall contain vaf meter, auto / manual selector swtich and indicating / pushbutton lamps with mcb for on / off / trip of motor. ( rain water to raw ) 298 d.2 no. suitable mccb for 5.0 kw outgoing feeders to borewell starter panel. each compartment shall contain vaf meter, auto / manual selector switch and indicating lamps with mcb for ‘on / off / trip’ status of motor 299 e.2 no. suitable mccb for 3.0 kw outgoing feeders to basementsump pump panel. each compartment shall contain vaf meter, auto / manual selector switch and indicating lamps with mcb for ‘on / off / trip’ status of motor ( 1 working and 1 standby ) 2 set 300 f. spare mcb’s of following capacities: 301 i. 40 amps tpn mcb’s 2 nos. 302 ii. 63 amps tpn mcb’s 2 nos. 303 a. all mccbs shall be of 25 ka breaking capacity and suitable for motor duty application. 304 b. provision shall be made for providing potential free contacts to all pumps starters for connection to bas 305 c. provision shall be made to ensure system protection from dry running of the pump 306 d. necessary cable alleys, internal wiring, and interlocking, earthing for all equipment shall also included 307 mcc 1for plumbing system as described above....

Rail Wheel Plant - Bihar

30234572 supply of analog volt meteranalog volt meter,nsd6 fuse, high rupturing capacity (hrc), nsd series, 6 a, blade tag, 550 vac, make : eaton bussmann/ siemens/ schneider electric only , hrc fuse 20a, 690v ac, 80ka, 250v d.c., 40ka,model 20ho7 660, make : eaton bussmann/ siemens/ schneider electric only , analog volt meter, range 0 600v, cl 1, model no. eq91, make rishabh/ ae/schneider electric only. , analog ac ammeter, range 0 180, 180/5a, input 5a, cl 1, model no. eq71, make rishabh/ ae/ schneider electric only. , analog power factor meter, input 110vac ,5a, range 0.5 1 0.5, cl 1.5, model no. cl 91d2c, make rishabh/ ae/ schneider electric only. page 1 of 4 run date/time: 11/12/2021 10:51:15lpstores/rwp/bela tender document...

Kanti Bijlee Utpadan Nigam Limited - Bihar

29812869 procurement of vfd spares for st 2 units vfd system in kbunl procurement of vfd spares for st 2 units vfd system in kbunl , voltage divider card: ed660xptna00; bhel , vfd lci pcb card: pcb660ntda aia; bhel , power supply module: ed660dpsa a00; bhel , cable for vfd ct, 10kv, strands 19 / 029, , card ds38000xtfy 660xtfya of bhel vfd , metal oxide varistor 660 volts, 2300 jou , metal oxide varistor 880 volt rms, 3200j , wattmeter ac scale 0 2500 kw for vfd. , limit switch ( 75 s / t 6nos+33sc 6nos ) , ce7403299043 ct vfd current transformer , ce7403297024 ct vfd current transformer , ce7403199030 vfd control transformer , cu7403199413 vfd control transformer , cn9751166209 vfd control transformer , cn9074474136 vfd control transformer , , bch catno krtpn20 range 0.05 to 60 sec , cap elctrlt:4800ac:1.0 mfd , ammeter ac range ( 0 800a ) input ( 0 10v ) dc , speedometer scale 0 750rpm , volt meter 0 3000 v, dr0701080060, vfd...

National Thermal Power Corporation Limited - Bihar

28566870 proposal for procurement of mill, bmd, tmd, ci and emd spares on oem / oes proposal for procurement of mill, bmd, tmd, cndi and emd spares on oem / oesbasis at ntpc farakka , epoxy hardener hy 840 or equivalent , ms strainer gasket , groove ring41232001095 032 , pure graphite seal ring size 330x280x35 , seal ring, i.d.=210mm & o.d.=230mmgraph , adjusting screw m8x70 , control sleeve 25*47 , split pin 2.0 x 25 , pin cyl a12d 16x134 , pin taper 4x20 , pin taper 6x26 , pin taper 8x45 , split pin 3.2 x 20 , sealing ring a22x37 , bushtg 210 mw protection spray water , pintaper 5x50 , valve disc for lpb v / v ( spray valve ) , cover41232001086 010 , thrust ring41232001089 013 , bushtg 210 mw protection spray water , threaded ring m 72x2 , grub screw cm 6x10 is:6094 , o ring 115x4 , o ring 250x4 viton , automatic groove ring set 11x30 , automatic groove ring set 11x30 , 69208hrdda plus relay driver , 660nliba flux calculation card , 660nlcba plus signal conditioning board , 660dliba plus daughter board load invter , 660xtfyb ds3800xtfy plus display module , input / output module for vfd , card ds 38000 hmpg 660hmpga of vfd bhel , card dmpb 660dmpba ed660 dmpba00 of vfd , card ds 38000 hlcb 660 hlcba of bhel vfd , card ds 38000 haia660 of bhel vfdanalog , card ds38000nsfc 660nsfca of bhel vfd , card ds 38000 dsfc 660dsfca of bhel vfd , card ds 38000 nsfe 660sfea of bhel vfd , card ds38000 dsfc 660dsfea of bhel vfd , card ds38000 dlcb 660d dlcba of bhel vfd , card ds38000 nlib 660nliba of bhel vfd , card ds 38000hisa 660hisaa of bhel vfd , card hrdda ed69208hrdda of bhel vfd , card ds38000xtfy 660xtfya of bhel vfd , control card evc / sfe, ed660nhvla00, vfd , high level relay o / p board ds3800hroa , fan loss card evc / sfe ds3800nfla , gear hub key of m.drv&bowl mill xrp803 , mill bottom cover ( mbc ) assy mill xrp803 , upper brg.hsg.cover assy m.drv xrp803 , seal runner assy of m.drv& mill;xrp803 , piping assy exh; 3 / 4 mill xrp803 , dust guard shim m.drive&bowl mill xrp803 , split oil seal a890 assy mill xrp803 , split oil seal runner; a889 mill xrp803 , metallic exp.bellow exh mill xrp803 , metallic exp.bellow of mill xrp803 , o / l ventury o collar assy mill xrp803 , oil pump bushing , upper skirt assy , lower skirt assy , oil pump hub , separator access door , upper journal housing , split type fixing ring#4 61 180 00681 , worm shaft extension cap for xrp 803 mil , st of shims ( lower brg. and pump hsg ) , multiple port outlet plate liner , deflector blade , insulation cover plate assy. segmts 8 no , journal head with trunion shaft , cn9061182484 vfd limiter / surge suppresor , cn9061182492 vfd limiter / surge suppresor , vfd cn9751091691 limiter / surge suppresor , gate & rack plate , 16722500032 / 01 , gear wheel, 36721300067 , gear wheel, 36721300068 , vfd spare resistor ww11r + / 10%, 750w , resistor, w.w.17r + / 10%, 750w, for vfd , aux relay six units in one case for vfd , time delay relay on / off delay , vfd power / control fuse , ltsh:bifurcate :d44.5x5.3 t11 , ltsh:bifurcate :d44.5x5.3 t11 , ltsh:bifurcate :d44.5x5.3 t11 , ltsh:bifurcate :d44.5x5.3 t11 , ltsh:bifurcate :d44.5x5.3 t11 , ltsh:bifurcate :d44.5x5.3 t11 , feed tube assy. 200 / 210 , rotary chian 3 / 4 p tp73660260000 , lrsb carriage gear assy. , lance tubet 30 mark ie t 7.2m , rack pinion tp72020120222 , worm tp720201212312 , swivel tube assy ****tp72020122831 , sbv head assy. lrsb 57r / 58l.8420 2..01 , v / v stem assy.lrsb 57r / 58l.8420 00166501 , sb spring retnr sprng stl tp720001078216 , stem for main steam valve 931159140000 , class 2500 f.a.s., sw, regu. globe valve , transition piece coal burnr tp7..2118 , ceralined orifice dia 396mm, style51 , ceralined orifice dia 406mm, style53 , ceralined orifice dia 410mm, style54 , ceralined orifice dia 420mm, style56 , ceralined orifice dia 430mm, style58 , ceralined orifice dia 435mm, style59 , turbo separator for drum internal assy. , mov ord:q69 x3728 siov b60k460 for vfd , wattmeter ac scale 0 2500 kw for vfd. , volt meter 0 3000 v, dr0701080060, vfd , journal shaft hy 610800213001 , journal bearing keeper; xrp 803 mill , lower brg & pump hsg mill xrp803 , gasket ( pump hsg.cover lower ) mill xrp803 , spring ( thrust brg ) w / shaft mill xrp803 , clamping ring;set=2;is:1030 mill xrp803 , link / conn.rod+jamnut clasifier xrp803 , shim set=15no ( journal brg.hsg ) of xrp 803 , journal head skirt of j / assy of xrp803 , mill side bottom liner;st=9pcs of xrp803 , shims , mill disch assy ceramic lined mpo xrp803 , oil gauge&piping assy#bd00121 xrp803 , deflector link lever mill xrp 803 , w / s / t / hsg.cover w.shaftassy mill xrp803 , 36 r.c feeder inlet gate gear 3:1 , pinion for gear reducer for raw coalgate , chain take up block; make:bhel; , chain take up screw; make:bhel , bunker o / l gate assy+wheel+chain+act 36 , roller ( weigh span ) for grav feeder , view glass of feeder door , hria relay input board: ds3800hria; ge , power supply module: ed660ntrfb; bhel , power supply module: ed660dpsa a00; bhel , journal head liner i for mill xrp 1003 , journal head liner ii for mill xrp 1003 , journal head liner for bwl mill xrp 1003 , deflector hinge shaft for mill xrp 1003 , air inlet side wall liner for xrp 1003 , air inlet side wall liner for xrp 1003 , air inlet side wall liner for xrp 1003 , mill side liner var no.02for xrp 1003 , mill inspectoin door liner make bhel , high temp blanket insulation 48x48x2 , upper skirt assy.for xrp 1003 mill , spring preload stud for xrp 1003 mill , head pulley bushing; make:bhel; , split pin 0.8 x 10 , bushtg 210 mw protection spray water , tension spring , tension spring , adjusting screw , automatic groove ring set , bush41232201035 015 , bush31232201034 014 , bushtg 210 mw protection spray water , comp spring drg:01140203000 / 27 , collar nut drg:01140101000 / 38 , bush drg:01120201000 / 12 , bush drg:01120201000 / 11 , threaded ring drg:01120201000 / 05 , pulse distribution board mvb ds3800xtfh , voltage divider card: ed660xptna00; bhel , thyristor for 1.2kv lci vfd panel , block belt take up; make: bhel; , drag link assly.;make:bhel , tension roll pivot bolt; make:bhel , belt take up pulley shaft; make: bhel; , half coupling; make: bhel; , journal spring for xrp 1003 mill , spring seal assly bottom cold air gate , spring seal asy guillotine hot air gate , springseal bottom guillotine hotair gate , springseal port guillotine hot air gate , springseal bonnet guilotine hot air gate , seal asy blade to blade cold air damper , seal asy ( blade fr ) cold air damper , seal asy ( blade frame ) hot air damper , seal asy ( blade to blade ) hot air damper , pilot seat bushg for elec rv outlet , 660hisaa attenuator & buffer board , roll pingear box, f2 / mtp / bla / a3 03117 , stem for soot blower puppet valve, sb , valve spring, puppet valve, wall sb, wb 1e , worm gear shaft assy, wall sb, wb 1e , spur gear 12 teeth, wall sb, wb 1e , ltsh:bifurcate :d44.5x5.3 t11 , ltsh:bifurcate :d44.5x5.3 t11 , ltsh:bifurcate :d44.5x5.3 t11 , upper journal housing;xrp 1003 , o ring oil seal ;xrp 1003 , journal stop bolt:xrp 1003 mill , journal stop bolt bushing;xrp 1003 mill , oring id584 sec dia 6.5, mill xrp 1003 , spring stud bearingfor xrp 1003 mill , o ring oil seal var 04: mill xrp 1003 , outlet plate liner, mill xrp 1003 , insulation cover plate for xrp 1003 mill , spring seal assy. ( bonnet ) for cag , spring seal assy. ( port ) for cold air gat , spring seal assy. ( side ) for cold air gat...

Bharatiya Rail Bijlee Company Limited - Bihar

27938612 procurement of spares for chloride make 220 v 400 a dc battery charger , dc filter choke:kab 1120 for 5 kva ups , dcps card for dig.meter: dcps01;chloride , control xymr:250va, 415v 230v , control xymr:150va, 415 / 230v , ac.input switches type, sc1034 / 100amp , 96 sq.mm ac ammeter, 0 300a , ammeter dc 0 1500a 96x96 mm is1248 clas1 , ac volt meter ( 0 500v ) , avr dc voltmeter0 300v 72x72mm , pwrcontr:240vac 100a seimens;3ta13 , 200a d.c . shunt , overload relay 85 135 amp , 200a, semicon fuse, gec make , transformer 50 kva , contactors 230v dc, 3no+1nc for aux. cont , current transformers 300 / 1a...

Public Health Department. - Bihar

27916228 supply of ss ring fountains header 09 ft. dia with fitting supply of 55 ring fountains header 08 ft. dia with fitting supply of ss ring fountains header 06 ft. dia with fitting supply of water flow control adjustable nozzle supply of central jet nozzle supply of sub. open well pump 7.5 h.p. with complete fining supply of ss under water led light 18 wait with rgb effect supply of cvd for led tights supply of outdoor star delta control panel made of 16 gauge crc sheet powder coated with starter, single phase prevention, mcb volt meter, ampere meter, tp mcb’s protection circuits etc. supply of clectrical cable 4 core and cable 3 cores up to 35 mtrs providing plumbing work accessories, control valves, nipples tee, mta, union socket piping in upvc 6kg/cm2/lokg/cm2 pressure with complete fining valves with 151 mark. supply & installation & complete fountains work, with complete civil structure as per direction of e.i. ________ one year operation & maintenance...

Government College - Bihar

27137326 supply of laboratory apparatus , chemical and furniture 1 arc indicator 2 carry foster bridge 3 camera lucida mirror type 4 bar pendulum lron 5 bending of beem app 6 boyle law app double and routine 7 dynmo model acldc superior quality 8 double lncline planl teak wood , physical balance ,physical weight box ,qube sett set ,meter scales wooden ,half meter scales wooden ,bar magnet ,u magnet ,horse shoe magnet ,magnet set white box ,rubber corks ,slotted weights 1st qty. ,lnertia table app ,lncline plane 4 aluminum arc ,k constant spring app. alum scale ,hook s law app , drawing boards ,boyles law apparatus ,traveling microscope ,copper calorimeter ,solonid ,ammeter ,volt meter ,object stand of wire mesh ,jaguer app ,specific gravity bottles ,soldering gun gum, lead wire ,velocity of sound in air apparatus ,stop clocks ,jagger app complete ,logic gate ,maxwell vibration needle brass ,mew apo ,model of bio gas plant ,model of newton law of cooling university ,post office box brass ,rubber hammers , optical bench 1 mtr s,s with rod ,spectrometer , commutator ,tunning forks ,magnetometer compass ,copper calorimeter ,tripod stands , rheostat , reading telescope ,tangent galvanometer bras deluxe ,surface tension app ,model of newton colur disk ,high resistance coil 10ohms ,connecting wires ,wooden stands v shape ,wooden screens black and white ,geometry boxes ,deflection of sound ,resistance boxes 500 ohms ,potential meter ,manganese wire ,nichrome wire ,soldering lead ,weighing machine ,model of wind mill ,model of four stroke petrol engine ,newton first law ,newton second law ,newton third law ,fraction board app etc...

District Collector - Bihar

26299920 supply of cleaning , sports , cultural program , gardening , student useful , laboratory stationery material broom , wiper , harpik ,phenyl , dustbin , football , volleyball , volley ball net , badminton , badminton net and crock, satranj , ludo , cricket bat , ball , bells , adi , gola , carrom board , gola , rope , cricket gloves , pad , helmet , kudal , khurpi , hasua, tagar , khenti , dabiya , bucket , jug , harmonium, dholak, tabla , sound box, loud speaker , battery , jhal , mike stand , blanket , mattresses , single coat , mosquito net , chair , table meeting hall , spoon , glass , bowl , spoon ,lens , mirror ,wire , ammeter , volt meter , connection wire , cell , sand paper , mirror slab , stream controller dry cell , plug key , hydraulic acid , sulphuric acid , sodium hydroxide , potasium hydrooxide , p h paper , bricker , test tube , mirror tube , holder , asut water , litmus paper ,jasta powder , iron , copper , aluminum , gas burner , test tube holder and stand , filter paper , dropper , microscopes , watch glass , petry dish , tripal tarpaulin grill , alcohol , iodine , sokhta paper , chimta , slide , glycerin , sefronin , wooden well , plain paper , roiling paper register , pen , tag , pin , cover file , refill , carbon , letter pad , whitener , stapler pin , machine , steel trunk , almirah , scale , ceiling fan , condenser , led bulb , fire extinguisher system , ro system etc ...

Irrigation Department - Bihar

25336429 supply of new starter , new main switch , aluminum wire , flat cable , copper wire , kit kat , top and bottom bearing , volt meter , ampere meter , automatic starter , bulb + holder set ,submersible motor , ms column pipe with socket , automation starter with mccb panel , surge tank , mcb , flat cable , retainer bearing with rubber bush , foot valve,pvc copper wire , pvc service wire copper , flat cable , aluminum insulated wire , copper holder , indicator bulb , gm bush upper , fix contest moving contest , tt plate , tt bush , nut bolts etc ...

Minor Irrigation Department - Bihar

25318431 supply of new starter, new main switch, aluminium wire, flat cable, copper wire, kit kat, volt meter, ampere meter, automatic starter, mccb panel, bulb, holder set, submersible motor, ms colum pipe with socket, v.t. motor rewinding, mcb, socket, retainer bearing with rubber bush, foot valve, indicator bulb, cfl, gm bush, bearing, moving contact, nut bolts, chain pulley, pipe wrench, sluice valve, mf flange, agni saman hydrant, clamp, sluice valve....

Irrigation Department - Bihar

25229725 supply of materials new submersible motor , crompton greaves , rewinding of submersible motor , starter isi mark ,automatic starter with mccb , main switch , fuse wire , volt meter , ms nut bolt , ms bush , ms screw , ms washer , kit kat ,surge tank , panel board , flexible pvc pipe ,ms column pipe with socket , ms socket , ms flange , ms tee ,pvc tee , rubber washer ,sluice valve , ms bend pipe ,l bend ms pipe , bearing , tt plate , tt bush , over load coil magnet coil , bulb ,indicator bulb , ms danger plate , fiber plate , steel grip tape ,copper wire , pvc insulated copper wire , three coare flate cable , aluminum wire , aluminum insulated wire , pvc single core aluminum etc ...

Minor Irrigation Department - Bihar

25077151 supply of new starter, new main switch, aluminium wire, flat cable, copper wire, kit kat, bearing, volt meter, ampere meter, automatic starter, mccb panel, bulb, holder set, submersible motor, surge tank, socket, mcb, flat cable, pvc copper wire, indicator holder, bulb, cfl, bush, main switch, over load coil, no volt coil, moving contact, fix contact, magnet coil, fibre plate, tt plate, tt bush, nut bolts, pvc ftp, ms flange, rubber gasket, pvc tee, bend, chain pully, chain wrench, sluice valve, foot valve, non return valve, ms flange, agni saman hydrant, clamp....

Jawahar Navodaya Vidyalaya - Bihar

20670279 supply of science laboratory + 2 (secondary) for year 2019 20 1 ammeter with stand dc super deluxe / omega 2 voltmeter with stand dc super deluxe / omega 3 galvanometer with stand dc super deluxe / omega 4 mili volt meter with stand dc super deluxe / omega 5 mili ammeter with stand dc super deluxe / omega 6 calorimeter with stirrer 7×5 cm in wooden box 7 fortins barometer (omega) 8 potentiometer ten wire with sliding jockey omega 9 copper voltmeter 10 deflection magnetometer with compass 11 scale 1 meter wodden 12 scale 1/2 meter wodden 13 tripod stand 6 best quality 14 wooden cube / wodden sphere / wooden cylinder 15 pin stand metallic 16 drawing board 12 × 18 pine wood 17 drawing pin 18 compass needle 3 19 rubber tube size 7/8 mm 20 plug connector 3 way 21 sprit lamp metallic ( stainless steel) best quality 22 bar magnet / horses shoe magnet 3 allinco 23 bar magnet / horses shoe magnet 2 allinco 24 rheostal 50 / 100 omhs) 6 25 rheostal 50 / 100 omhs) 6 best quality 26 dry cell 1.5 volt 27 meter bridge one wire one meter long with jockey omega 28 laclanche cell 29 p.o. box 5000 ohms constant coil (omega) 30 p.o. box 20000 ohms constant coil (omega) 31 lead accumulator 32 apparatus for speherometer method 33 wire gauige 6× 6 with frame best quality 34 tapping key 35 resistant box 500 ohms 36 plumb line 37 beaker . cap. 250 ml ( borocilicate) 38 beaker . cap. 500 ml ( borocilicate) 39 beaker . cap. 1000 ml ( borocilicate) 40 inclined frictional table 41 inclined plain 42 plug key one way 43 plug key two way 44 plug key four way 45 traveling microscope horizontal (omega) 46 slotted weight for sonometer set of five ( 500 gm. each) 47 tunning fork export quality 48 prism glass 2 49 glass slab 3/4 50 boiler (copper) cap. 1 lit 51 convex & concave lenses & mirrors 2 (dce) 52 convex & concave lenses & mirrors 2.5 (dce)...

Labour Department - Bihar

18802713 supply of tools & equipment training materials, consumable material 419 tubeless tyre of cars & trucks 420 tubeless tyre repairkit 421 tubular box spanner 422 turbocharger cut sectional view 423 tyre pressure gauge with holding nipple 424 tyre& split rim wheel assembly 425 universal puller for removing pulleys,bearings 426 urinal wall type complete with automatic system 427 v’ block 75 x 38 mm pair withclamps 428 vacuum assisted hydraulics brake assembly with vacuum booster 429 vacuum gauge to read 0 to 760 mm of hg. 430 valve key handle[treated as consumable] 431 valve spring compressor universal. 432 valvelifter 433 vernier caliper 434 vernier caliper 0 300 mm with least count0.02mm 435 vice grip pliers 436 volt meter 50v/dc 437 voltmeter, ac/dc portable precision grade digital panel board type 438 water pump for dismantling and assembling 439 wattmeter multi range up 440 wheelcylinder 441 wing compass 25cm 442 wiper motor assembly 443 wire cutter andstripper 444 wire gauge metric and withworth 445 wire gauge(metric) 446 wire stripper 447 wrench adjustable 448 1 phase variable autotransformer 449 4 point relays 450 5 point relays 451 5/8 passenger lift installed with all control and safety accessories 452 a.c. ammeter m.i. 0 5a, 0 25a 453 a.c. energy meter, single phase 5 amp. three phase 15amp 454 a.c. voltmeter m.i. 0 –500va.c 455 ac 3 phase motor, 400/50hz 456 air bag simulator 457 air conditioned crdi vehicle in running condition lmv 458 air conditioning service unit(car) 459 air conditioning trainerkit 460 air compressor, 461 air conditioning, direct and indirect system. ammeter mc 0 5 a, 0 25a...

Labour Department - Bihar

18802706 supply of tools & equipment training materials, consumable material 129 out side micro meter 130 outside and inside dividercalliper 131 outside micrometer 0 to 25mm 132 outside micrometer 25 to 50mm 133 outside micrometer 50 to 75mm 134 outside micrometer 75 to 100mm 135 ammeter 300a/ 60a dc with externalshunt 136 ammeter, ac/dc portable precision grade digital panel boardtype 137 anemo meter 138 dc ohmmeter 0 to 300 ohms, mid scales at 20ohms 139 dc ohmmeter 0 to 300 ohms, mid scales at 20ohms 140 k.w.meter 141 multi meter analogue type 142 multi meter digital type 143 volt meter 50v/dc 144 voltmeter, ac/dc portable precision grade digital panel board type 145 water meter 146 a.c. ammeter m.i. 0 5a, 0 25a 147 a.c. energy meter, single phase 5 amp. three phase 15amp 148 a.c. voltmeter m.i. 0 –500va.c 149 ammeter mc 0 5 a, 0 25a 150 9 tine cultivator spring loaded mounted type 151 a.f.o oscillators 152 ac alternator slip ringpuller 153 adjustable spanner (pipe wrench 350mm) 154 air blow gun with standardaccessories 155 air brakeassembly 156 air impact wrench with standardaccessories 157 air ratchet with standardaccessories 158 allen key set of 12 pieces (2mm to14mm) 159 alternator assembly used forlmv 160 alternator for tractor – differenttype 161 ammeter 300a/ 60a dc with externalshunt 162 ammeter, ac/dc portable precision grade digital panel boardtype 163 anemo meter 164 angle plate adjustable250x150x175 165 angle plate size200x100x200mm 166 anti theft device 167 anvil 50 or 63 kg. is 510 168 arbor press hand operated 2 toncapacity 169 auto electrical testbench 170 automotive exhaust 5 gas analyzer (petrol & diesel) diesel smoke meter 171 axle flow vegetable thresher...

East Central Railway - Bihar

15824000 samo suraksha kavach super saver pump management system with complete protection for motor failure like short circuit, over current, dry run single phasing, phase unbalance, over / under voltage, locked rotor, ground fauilt, pre trip alert indication in case of over load condition along with digital display of trip cause, capacity40hp / 30kw, suitable for 3 phase, 415v, 50hz, with sfu and digital volt meter of 500v, cat. no. sksupmcsds40. make shree shakti industrial agency or equivalent....

East Central Railway - Bihar

15822210 samo suraksha kavach super saver pump management system with complete protection for motor failure like short curcuit, over current. dry run, single phasing, phase unbalance, over / under voltage, locked rotor, ground fauilt, pre trip alert indication in case of over load condition along with digital display of trip cause, capacity 20 hp / 15 kw, suitable for 3 phase, 415v, 50hz, with sfu and digital volt meter of 500v, cat.no. sksupmcsds20. make: shree shakti industrial agency or equivalent....

East Central Railway - Bihar

15293821 tender for auxiliary line volt meter moving iron type 152x70x133mm, range 0 600v/0 35kv, scale 82 mm for wag5,w...

East Central Railway - Bihar

15064577 tender for auxiliary line volt meter moving iron type 152x70x133mm, range 0 600v/0 35kv, scale 82 mm for wag5,w...

East Central Railway - Bihar

14084829 supply of auxiliary line volt meter moving iron type 152x70x133mm, range 0 600v/0 35kv, scale 82 mm for wag5,w...

Public Works Department - Bihar

13243676 tender for supply, installation, testing & commissioning of cubical type floor mounted fire pump control panel fabricated from 14 g m.s. crc sheet duly powder coated finish of approved shade and comprising of : a ) one 630amp. tp +1‘41„ m.c.c.b with rotary handle of breaking capacity 35ka b ) one volt meter ( 0 500 v ) with selector switch c ) one set indicating lamps bus bars outgoing a ) 800 amp tpn bus bar ( aluminum ) . b ) two 400 amp. tp + nl m.c.c.b. with rotary handle of breaking capacity 35ka c ) one 63 amp.tp +nl m.c.c.b. with rotary handle 7 of breaking capacity 35ka d ) two fully automatic star delta starters suitable for 115 i i.p. pump motor with over load relay timer push buttons and .auto / manual selector switch...

East Central Railway - Bihar

12531478 supply of evacuation machine, pump and tank assembly, trolley mounted with accessories. make kirloskar or similar annexure attached . specification: 1 vaccum suction pump fitted with electric motor: a specification of vacuum pump: discharge head 1.5 , input head 2 , capacity 100 cfm, body cast iron, model smp make kirlosker or similar. b specification of motor: hp 3.5, rpm 2800, voltage 430 440 v, hz 50, phase 3, model induction cupping, make kirlosker or similar, 2 fittings and spares of vacuum pump: a flexible pvc pipe dia 2 inch, make zen or similar, b pvc ball valve dia 2.5 inch, make zen or similar, c pvc ball valve dia 2 inch, make zen or similar, d g. i. nipple 2 inch x 6 inch, make tata or similar, e g. i. elbow 2 inch x 6 inch, make tata or similar, f ms coupler 2 inch x 6 inch, make tata or similar, g ms pipe connector 2 inch x 6 inch, make tata or similar, h frame of vacuum pump made of ms angle push and pulling fitted with syevel castrol wheel pvc tank, make syntex or similar. 3 electrical spares: a duel starter, hp 3.5, volt 440, amp 65, model mk 1, make l and t or similar, b amp. meter range 0 100, volt 0 440, c volt meter, range 0 550, d cable, 4 core 3/22 swg, e indicator lamp, 10 amp., 220 v, red, blue, yellow , f mcb, 440 volt, 65 amp., 3 phase, 5 pin metal body socket, 440 v, 32 amp fitted with cable....

East Central Railway - Bihar

11891415 supply of evacuation machine, pump and tank assembly, trolley mounted with accessories. make kirloskar or similar annexure attached . specification: 1 vaccum suction pump fitted with electric motor: a specification of vacuum pump: discharge head 1.5 , input head 2 , capacity 100 cfm, body cast iron, model smp make kirlosker or similar. b specification of motor: hp 3.5, rpm 2800, voltage 430 440 v, hz 50, phase 3, model induction cupping, make kirlosker or similar, 2 fittings and spares of vacuum pump: a flexible pvc pipe dia 2 inch, make zen or similar, b pvc ball valve dia 2.5 inch, make zen or similar, c pvc ball valve dia 2 inch, make zen or similar, d g. i. nipple 2 inch x 6 inch, make tata or similar, e g. i. elbow 2 inch x 6 inch, make tata or similar, f ms coupler 2 inch x 6 inch, make tata or similar, g ms pipe connector 2 inch x 6 inch, make tata or similar, h frame of vacuum pump made of ms angle push and pulling fitted with syevel castrol wheel pvc tank, make syntex or similar. 3 electrical spares: a duel starter, hp 3.5, volt 440, amp 65, model mk 1, make l and t or similar, b amp. meter range 0 100, volt 0 440, c volt meter, range 0 550, d cable, 4 core 3/22 swg, e indicator lamp, 10 amp., 220 v, red, blue, yellow , f mcb, 440 volt, 65 amp., 3 phase, 5 pin metal body socket, 440 v, 32 amp fitted with cable....

Building Construction Department - Bihar

10597728 tender for installation of 45 m deep 110 mm dia submersible motar with boaring in data cum record room.: supplying installing control panel consisting starter volt meter ampere meter overload relay off / on switch ( volt. supply 300+100 / all . enclosed in m.5 sheet box of approved make....

Building Construction Department - Bihar

9392849 tender for supply and installing control panel consisting starter volt meter ampere meter overload relay off on switch volt supply 300+100 all enclosed in ms sheet box of approve make....

Building Division - Bihar

9386067 tender for supplying and installation of suitable panel board with all accessories starter volt meter etc...

East Central Railway - Bihar

8337698 volt meter range 0 500 v square flush type 96 mm 230 v,50 hz, single phase ac , make bentex, capital or similar....

Public Health Engineering Department - Bihar

8226131 supplying installation and commissioning of 5 hp 3 phase submersible motor pump set with all accessories including nr valve, sluice valve, pressure gauge, ms colvmn pipe, clamp starter main switch, amp, volt meter, power and light wiring, kit kat earthing etc work and supply / fixing sv lamp and tripod with chainpully block arrangement....

Building Division - Bihar

6505371 supply of pvc pipes, strainer and jointing materials, 100 mm diameter casing pipe, supplying and fixing pvc fitting, ms clamps 100 mm diameter, supplying miscellaneous items, earth work in excavation, supplying pea gravels, developing of tube well, supplying installation and commissioning submersible pump and motor set, control panel consisting starter , volt meter, ampere meter, overload relay, ms clamps 40 mm diameter with nut bolts....

Tubewell Construction Department - Bihar

6176148 supply of starter 415v,main switch,amp.tr, volt meter, 6m m2 p.v.c. insulated submersible cable i.s.i. fuse bridge ,single core aluminum p.v.c. wire,starter oil, p.v.c. winding wire ,fuse wire, p.v.c. wire 7/20, no volt coil assembly , overload coil assembly, nbc ball bearing 545/345, rubber bush, thrust plate, fixed contect, moving contect,super enamel copper wire, g.m. bush , sand guard, thrust bearing, i bolt with nut, drain plug, cable guard, lock ring, 6’’ dia m.s. flang, 6”m.s. clamp,socket, neck ring, spider , rubber bush, t.t. plate, g.m. center guide, g.m. gland plate, thrust plate, bush for saft sleeve, t.t. plate bush , c.i. coupling, pully for motor, coupling with key, roller plate (v.t.)...

Police Department - Bihar

5483256 supply of a.c. mili volt meter, repeater station a/w cable and antenaa l/b, fixed station for interlinking repeater....

Urban Developmant Authority - Bihar

4910921 supplying, installation and commissioning of submersible pump and motor set, control panel consisting starter, volt meter, ampere meter, over load relay, supply, fixing and fitting of 1.5 square mili meter submersible cable, ms clamps with nuts bolts, gun metal gate valve. ...

Police Department - Bihar

4355760 supply of air conditioner mili volt meter, repeater station a/w cable & antenna l/b, fixed station for interlinking repeater, collar mikes for hand held sets, 25 watt. vhf set with scrambler all accessories, vhf set ...

Bihar State Power Company Limited - Bihar

4159976 supply of avo meter, watt hour meter,volt meter,amp. meter,ratio meter automatic),electronic multimeter,electronic tongue tester,electronic low resistance meter,kelvin bridge ...

Building Division - Bihar

3543262 supply of items for boring and water supply works – boring by reverse type rotary machine, equipments – supplying pvc pipes, strainer and jointing materials including all taxes), 100mm dia.meter casing pipe, supply and fixing of pvc fittings, m.s. clamps with nut bolts, supplying miscellaneous items such as urea, cow dung’s, etc.) for development of tube well including transportation and other cost of complete, earth work in excavation digging pits) for storage of water required for making the bore holes as mentioned above and disposal of excavated earth, including all lifts, removing roots of trees, shrubs, lowering the complete assembly of pipes, strainer and other allied fittings, supplying pea gravels, development of tube wells by air compressor for minimum period of 12 hours or till the fresh water, supply, installation and commissioning of submersible pump and motor set capable to deliver at 100 liter per minute fresh water at a total head of 40.00 meter of approved make, supplying, installing control panel, consisting starter, volt meter, ampere meter, volt meter, supply, fixing and fitting of 1.5 square milli meter submersible cable of finolex /emgee or equivalent, supply, fixing and fitting of 1.5 inches diameter pvc column pipe, ms clamps with nut bolts, gun metal valve. ...

Building Construction Department - Bihar

3130476 supply of items for boring and water supply work, boring by reverse type rotary machine, form g.l. to 103.00 meter, equipments supplying of pvc pipes, strainer and jointing materials, casing pipe, pvc fittings, supply and fixing of ms clamps fitting with nut bolts, miscellaneous items such as urea, cow dung etc.) for development of tube well, earth work in excavation for storage of water required for making the bore holes including all lifts, removing roots of trees, shrubs all completes, lowering the complete assembly of pipes, supplying pea gravels of approved quality, development of tube wells by air compressor, supply, installation and commissioning of submersible pump and motor, panel consisting starter, volt meter, ampere meter, over load relay, off/on switch all enclosed in m.s. sheet box of approved make, supply, fixing and fitting of milli meter submersible cable, pvc column pipe, ms clamps, gun metal gate valve fitting....