Purvanchal Vidyut Vitaran Nigam Limited - Bihar

45579884 tender for roof treatment of control room and other miscellaneous civil work at 33/11 kv substation shahganj, sonbhadra, 1 excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.5m and lead upto 30m and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of the foundation work. (code no. 2.6.1) 2 1:5:10 (1 cement : 5 coarse sand (zone iii) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) excluding the cost of centering and shuttering all work up to plinth level . (code no. 4.1.10) 3 providing and laying in position cement concrete of specified grade 1:2:4 (1 cement : 2 coarse sand (zone iii) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) excluding the cost of centering and shuttering all work up to plinth level . (code no. 4.1.3) 4 providing and laying 1:1½:3 (1 cement: 1½ coarse sand (zone iii) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : (code no. 4.1.2) 5 reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone iii) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (code no. 5.3) 6 centering and shuttering including strutting, propping etc. and removal of form for lintels, beams, plinth beams, girders, bressumers and cantilevers (code no. 5.9.5) 7 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in foundation and plinth in cement mortar 1:6 (1 cement : 6 coarse sand). (code no. 6.1.2) 8 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level in all shapes and sizes in : (code no.6.4.1) 9 brick work in foundation & plinth with old dismantledbricks (supplied by department free of cost) and coarse sandmortar in 1:6 including supply of all other materials, labour, removing mortar & cleaning of old & used bricks,t&p etc complete. (csi no. 6.18)(nsi no. 3) 10 steel work welded in built up sections/ framed work, in gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. (code no. 10.25.2) 11 thermo mechanically treated bars of grade fe 500d or more. steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. (code no. 5.22a.6) 12 12 mm cement plaster of mix 1:4 (1cement:4coarse sand) (code no. 13.4.1) 13 12 mm cement plaster of mix 1:6 (1cement:6coarse sand)(code no. 13.4.2) 14 providing (12x15) mm section groove in plasterincluding all material, labour andt&p etc. required for proper completion of the work. (csi no. 11.16)(nsi no. 34) 15 champering the edge of concrete in auxiliary structure, of size 25 mm wide in triangular section including all materials, labour & t&p etc complete. (csi no.11.18)(nsi no. 35) 16 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 30 mm thick including isi marked stainless steel butt hinges with necessary screws(code no. 9.20.2) 17 6 mm cement plaster 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of lime wash on top of walls when dry for bearing of r.c.c. slabs and beams. (code no. 13.17) 18 providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm.(b) laying second layer of fibre glass cloth when the first layer is still green. overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. this will be allowed to air cure for 4 hours followed by water curing for 48 hours. the entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.for the purpose of measurement the entire treated surface will be measured. ( code no. 22.6) 19 cement concrete 40 mm thick with 20 mm nominal size stone aggregate flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. (code no. 11.3.1) 20 providing and laying vitrified floor tiles size of tile 600x600 mm in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding grouting the joints with white cement and matching pigments etc., complete. (code no. 11.41.2) 21 deduct for not using 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) bedding in laying of floor tiles and jointing with grey cement slurry @ 3.3 kg/ sqm.(code no. 11.42) 22 providing and fixing glass strips in 40 mm wide and 4 mm thick joints of terrazo/ cement concrete floors.(code no. 11.13.1) 23 painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :one or more coats on old work(code no. 13.99.1) 24 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade old work (two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface (code no. 13.112.1) 25 wall painting with acrylic emulsion paint, having voc (volatile organic compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. (code no. 13.82.2) 26 demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer in charge. (code no. 15.7.4) 27 demolishing r.c.c. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of engineer in charge.(code no. 15.3) 28 dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.(code no. 15.25) 29 providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.00 mm thick glass panes(code no. 10.30.1) 30 dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead of area 3 sq. metres and below (code no. 15.12.1) 31 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. (code no. 15.56) 32 removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete( code no. 13.88) 33 providing and fixing water closet squatting pan (indian type w.c. pan ) white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. (code no. 17.1.1) 34 providing and fixing wash basin with c.i. brackets, 15 mm dia cp brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required. (a)white vitreous china wash basin size 550x400 mm with a 15 mm cp brass single hole basin mixer (code no. 17.7a) 35 providing and placing on terrace (at all floor levels) polyethylene water storage tank, is : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (code no. 18.48) 36 providing and laying swr, pvc 110 mm dia ( finolex or equivalent ) pipe including cost of excavation, c.c etc including its jointing and connection, all materials, labour and t&p etc. required for proper completion of the work. (csi no. 27.29c) nsi sl. no.110 37 providing and fixing chlorinated polyvinyl chloride (cpvc) 15 mm nominal dia pipes pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge.. (code no. 18.8.1) 38 providing and fixing chlorinated polyvinyl chloride (cpvc) 20 mm nominal dia pipes pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge.. (code no. 18.8.2) 39 providing and fixing chlorinated polyvinyl chloride (cpvc) 25 mm nominal dia pipes pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge.. (code no. 18.8.3) 40 providing and fixing gun metal gate valve with c.i. wheel of approved quality (screwed end) :25 mm nominal bore (code no. 18.17.1) 41 providing and fixing c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 15mm nominal bore(code no. 18.53.1) 42 providing and fixing 15 mm nominal bore c.p. brass bib cock of approved quality conforming to is:8931 : (code no. 18.49.1) 43 supply & installation of electrical control panel of l&t / havells or equivalent make for submersible pump / pumpset containing contractor relay condenser.(csi no. 19.31a) for 1 hp pump set single phase) (nsi 55) 44 supply & installation ofsubmersible pump of k.s.b/ calama. or eqt. make including cost of labour, t&p and material required for completion of work. (1 hp outlet 32 mm dia. or more, head 78/30,discharge 1100/2800 lph) (csi no. 19.32a)(nsi 56) 45 lowering of m.s. column pipe in tubewell including supply of nuts, and bolts, packing and also carriage of pipe from workshop to site including all labour, t&p etc. required for proper completion of the work.a)80/65/50/40/32 mm dia. (csi no. 19.27)(nsi no. 51) 46 supplying and drawing following 3 x 2.5 sq. mm sizes of frls pvc insulated copper conductor, single core cable in the existing surface/ recessed steel/ pvc conduit as required.(dsr e&m 2022 1.17.12) 47 supply & fixing of steel wire rope forsubmersible pump including cost of labour, t&p and material required for completion of work.(csi no. 19.34)(nsi 57) 48 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc as required..group c (dsr e&m 2022 1.10.3) (code no. 27.01) 49 wiring point for plug with 1.5sq. mm fr pvc insulated multistrand single core copper conductor cable in pvc conduit pipe on surface with 1 sqmm frlsh pvc insulated multistrand copper conductor cable as earthwire drawn inside the conduit,piano type switch and ceiling rose/angle/batten holder on 3mm thick phenolic laminated backelite sheet etc,complete in all respects,as directed, including maching colour wash.(uppwd ele sch 2018 item no 124c) 50 wiring for circuit/ submain wiring with 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire of frls pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required.(dsr e&m 2022 1.14.2) 51 supplying and fixing 5 amps to 32 amps rating,single pole, 240/415 volts, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. (dsr e&m 2022 2.10.1) 52 supply and fixing of power plug with 15amps. 250v. flush type switch and 5pin 15a 250v. flush type universal socket in suitable m.s.box of 175x100x50mm size with phenolic laminated bakelite sheet cover 3mm. thick fixed with brass machinesscrews and cup washer(uppwd ele sch 2018 item no 1139) 53 supplying and fixing 63 amps, double pole, 240 volts, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required.(dsr e&m 2022 2.12.2) 54 supply and fixing of surface /flush mounting 12 ways spn distribution board with additional metal door without mcb complete in all respect as directed by eic(uppwd ele sch 2018 item no 1025 cat a) ...

Military Engineer Services - Bihar

45233184 tender for maintenance services and certain repairs at otm/md accn in sos area sports ground and kheriyama at mil stn gaya 1 dismantling of asbestos cement (corrugated, semicorrugated etc,) sheets in roof coverings. 2 dismantling of timber scantlings unframed work in filets, rails, posts, rafters, purlin etc under40 sq cm and over in each section, in any position specified. 3 dismantling stone slabs and tiles of any description or thickness in floors & pointed in any mortarall as specified and directed. 4 s & f of 6mm thick asbestos cement, corrugated or semi corrugated sheets in roofs, walls etc with l type or j type or cranked hook bolts in roof, wall etc as specified. 5 m & l for 6 mm thick asbestos cement two piece adjustable plain wing ridge 6mm thick fixed with l or j hook complete. 6 s & f pre painted galvalume aluminum zinc coating (az 150)gi based plain steelsheet 0.5mm thick of any coloure in ridge having tensile strength of 550 mpafixed with self tapping screws as spd and directed by eng in charge etc. 7 demolitionof stone/brickmasonry in cm or cement/ lime mortar including all qnoins, arches, pillars etc. 8 m&l for brick work with sub class b bircks straight or curved on plan exc 6mtr mean radius built in cm 1:4 complete. 9 m & l for non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in cm 1:4 complete all as specified and directed. 10 m & l for coloured glazed ceramic tiles in vertical surface 450x300x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10 mm thick screed bed in cm 1:3 complete all as specified and directed. 11 supply and fix cpvc fittings like ball valve of 25mm outer dia all as specified and directed. 12 s&f in repair white colour rotational three layer moulded polyethylene water storage tanks (cylinderical vertical with closed top) capacity 1000 ltrhoisted and fixed in position all as specified and directed by engr in charge including dismantling water tanks and removing to store complete. make; sintex/ rotex/ polycon 13 s & f in repair vitreous china wash down water closet pan (pedestal pattern), white including fixing bolts, but excuding flushing cistern and flush pipe complete. make : jaguar/hindware/kohler 14 s & f as in repair of vitreous china squatting pan, ‘orissa’ pattern, size 580 x 440 mm white, with integral foot rests water closet (squatt pattern) complete including provision of lime concrete bedding complete all as specified and as directed make : hindware/parryware/cera 15 s & f in repair 10 litre capacity pvc valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete. 16 s & f in repairs vitreous china wash basin, white, flat back, size 550 x 400 mm including a pair of bracket, 32mm dia cp waste and 15mm bore cp pillar tap screwed to iron pipe complete all as specified and directed. 17 s & f in repairs 15mm bore bib taps, chromium plated, fancy type cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed. 18 s&f in repair 15 mm dia bore pillar taps, fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered hot or cold with long screwed shanks and fly nuts, screwed for iron pipe and fixed. 19 s&f sinks with drainage board made of stainless steel 1.00 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm including waste pipe and coupling complete all as specified and directed. 20 taking down chowkhats or frames exceeding 1.50 sqm and not exceeding 4 sqm each compleate all as specified 21 s & f ofpressed steel frames 125 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed 22 m&l for 35 mm thick flush shutters, solid core construction, with block board core plywood face panels on both side, commercial type on both sidesincluding 5 mm thick edging/beading on exposed to view on sides & top complete. 23 s &f factory made 35mm thick second class hardwood glazed and skeleton shutter open rebate and prepare to receive glass gauze etc (without sash bars ) edge of framing divided into squares plain chamfer rounded fitted with cut and mitred beads size of members as specified in ssr i section 8 clause 8.24 compleate all as specified and directed 24 dismantling ceiling and wall boards of any type or any thickness inclluding cover fillets complete all as specified and directed 25 s & f of 4 mm thick hpsc (high pressure steam cured) pre primed textured designer board, water resistant, be placed in the grid system duly suspended with 2 mm dia gi bar hangers fixed with steel dash through fasteners from purlins of the roof complete all as specified. 26 m & l for anodised aluminium snap grid frame work for false ceiling all as specified and as directed. 27 m&l for granite (any type) work (table rubbed and polished) 18 to 20 mm thick in working platform and like including cutting for sink etc. in cement mortar (1:4) including rounding of edges and pointing in white cement (1:2) using marble dust with admixture of pigment to match.complete all as specified and as directed 28 taking down chowkats with shutters of any description or any size & refixing the same after laying of tiles all as specified and directed by engr in charge. 29 taking down cement plaster or wall tiles etc. on brick or stone wall etc including raking out joints, hacking for key, scrubbing down with water etc. 30 m & l rendering 15mm thick on brick wall or concrete surface in cement mortar 1:4 finished even and smooth without using extra cement including wpc as per manufacturer instruction complete all as specified and directed. (wpc will be measured seperately) 31 m & l rendering 15mm thick on roof or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed. 32 supply only liquid water proofing compound (sika latex power) 33 m& l for preparation of newely plastered surface of walls and applying two coat of cement base paint over a coat of primer complete. 34 m& l for preparation of newely plastered surface of walls and applying two coat of acrylic distemperover a coat of primer as in walls complete. 35 demolition of cement concrete concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level). 36 m&l for pvc (swr) pipessingle socketed, in any length with rubber ring joints, laid in trenches or in floors or walls of 110 mm bore of pipeincluding taking down etc complete all as specified and directed. 37 m&l for pvc (swr) pipessingle socketed, in any length with rubber ring joints, laid in trenches or in floors or walls of 75 mm bore of pipe including taking down etc complete all as specified and directed 38 s&f pvc (swr) bends isi marked any radius of 110 mm borewithaccess door complete all as specified and directed. 39 s&f pvc (swr) bends isi marked any radius of 75 mm borewithaccess door complete all as specified and directed. 40 taking up or down steel tubing 15 mm and connections, including cleaning for re fixing or removal to store. 41 s & f in repairs cpvc pipes 25/20 mm outer dia sdr 11 & plain cpvc sdr 11includig all fittings on walls/ceiling or laying in floors including necessary cutting/chasing of walls and floors complete. 42 m & l for providing 25 mm thick pcc type b0, 1 : 2 : 4, (using 12.50 mm graded aggregate) as inflooring complete . 43 mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips 44 m&l for rcc 1:2:4 type b1 (using 20mm graded aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like as specified. 45 m&l for formwork to sides and soffits of floor or roof beams, beam haunch ings, girders, bressummers, lintels, cantilevers, shelves including sup ports, overhangs, etc. also splays between floors and beams, etc. 46 m&l for providing water proofing treatment over cleaned roof surfaces with super thermo app modified water froofing membran comprssing of following for non approachable roof:(i) removal of existing roof treatment/mud puska and cleaning sweeping and washing and down with water to remove all dust etc from plastred roof surfaces/wall and filling of crack with sealing compound etc. (ii)bitumen based primer conforming to is 3384 1965 at 0.30 kg per sqm.(iii) one layer of super thermo app modified water proofing membran with non polyster reinforcement of make (m/s stp texsa ltd/hyperplus membrane of m/s iwl india ltd. m/s stp and tikki tar ltd ) 3mm thick and minimum weight @ 3.50 kg/sqm laid with gas torch and fasted on roof surfaces with roller. the over laps shall be sealed by flame including vertical surfaces after cutting necessary grooving and making good with pcc gola 1:2:4 type b1 etc adhere to bitumen all as per manufacturer instructions.(iv)applying two coat of aluminium paint @ 0.20 kg/sqm per coat over bitumen layers as per manufacturer instruction (application including side lap overlaps shall be provided not less than 10cm and jointed sealed with torch as per manufacturer instruction specification. 47 s&f of stainless steel grade 304 of kitchen plate rack of 900x750 mm complete all as specified and directed.(make nirali/prayag) 48 demolition of cement concrete reinforced in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work all as specified and directed. 49 m&l for preparing new steel surfaces and applying two coats of synthetic enamel paint over coat of red oxide, zinc chrome primer, surfaces of any description, over 10cm width or girth not otherwise described. 50 taking down chowkat or frame with shutter (without taking off shutters from the frames) area not exceeding 1.5 sq mtr each as specified. 51 s&f powder coated aluminium frame/shutters for windows, ventilators sliding/openable etc icluding joining cleat for fixing, locking arrangement, rubber beading, screws etc complete all as specified.make : jindal/hindalco/indalco. note : (i) glazing and wire mesh shall be measured and paid separetely. (ii) item shall be paid as per weight of aluminium section.(iii)the rate quoted shall be inclusive of the cost of neoprene beading, glazing pin, screws and powder coated fittings such as locking arrangement etc as required, which shall not be measured for arriving the weight(iv) the rate shall also be inclusive of complete packing with silicon gel around contacting surfaces of aluminium work, and including matching the existing. 52 s & f in repair galvanised mild steel wire cloth0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tacks or galvanised wire staples (to be fixed upto four storey of bldgs) complete. 53 s&f sheet glass 4mm thick pin headed/froasted and glazing with clips in squaire . exc 0.50 sq m in each pane as specified. 54 s & f of solid pvc door frame of size 50mm x 47mm made out of 5mm plain colour pvc sheet reinforced with m.s. square tube, suppling & fixing in opening as per specification & drawing. 55 factory made solid panel pvc door shutter 30 mm thick (style) consisting of frame made out of m.s. tubes for top & bottom rails. m.s. frame shall be covered with heat moulded plain colour pvc ‘c’ channel having a pvc sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour pvc sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour pvc sheet to be fitted in the m.s. frame welded / sealed to the stiles & rails with suitable pvc sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. 56 s&f 125 mm long stainless steel butt hinges with steel hinge pin etc. 57 s&f 150mm long aluminium anodised handle cast type and fixed d type 58 s&f 200mm long aluminium anodised barrel tower bolt and 12 mm dia fixed ...

Hpcl Biofuels Limited - Bihar

44069205 open tender enquiry for supply of spares for mist cooling system with servicing on door delivery basis at lauriya, west champaran, bihar; 1 supply of spares for mist cooling system as per following specification: 2 saran3 pvc eight way header assembly 3 saran 3 pvc mist creator nozzles (patent no. 211652) 4 pvc arm pipe ᴓ 63 mm x 750 mm long 5 pvc arm pipe ᴓ 63 mm x 1000 mm long 6 arm support with clamp ᴓ 16 (od) x 800 mm long 7 arm support with clamp ᴓ 16 (od) x 1000 mm long 8 solvent cement 9 service part 10 service charge for supervision for fitment of new materials by one supervisor. ...

Military Engineer Services - Bihar

42997759 tender for additional / alternator cum special repairs to md accommodation at mil station gaya; 2 item no 01 : m & l for vitrified ceramic tiles light shed 10 mm thick ( square or rectangular ) polished, area of each tiles not exc 0.36 sqm, in floors etc. set and jointed with cement and pointed in white or coloured cement to match over and incl 15mm thick screed bed or bedding layer with cm 1:4 complete all as specified and as directed. 3 item no 02: m & l for vitrified double charge tiles light shed 10 mm thick ( square or rectangular ) polished, area of each tiles exc 0.36 sqm but not exc 0.42 sqm each in floors etc. set and jointed with cement and pointed in white or coloured cement to match over and incl 15mm thick screed bed or bedding layer with cm 1:4 complete all as specified and as directed. 4 item no 03 : roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc.complete all as specified and as directed. 5 item no 04 : m & l for non skid ceramic coloured tiles 7 to 8 mm thick ( square / rectangular ) area of each tile exc 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and incl 15mm thick screed bed or bedding layer with cm 1:4 complete all as specified and as directed. 6 item no 05 : m & l for glazed ceramic coloured tiles in vertical surfaces 450 x 300 x 7 8 mmset and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick rendering in cement mortar 1:4on fair faces of brick work or concrete surfaces as backing for tiles including taking down old tiles complete all as specified and as directed. 7 item no 06 : dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing ) , removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. 8 item no 07 : m & l for machine cut kota stone slab flooring 20 25mm thick incl 15 mm thick cement screed base in cement mortar 1:4laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete including dismantling of stone slab of any thickness.complete all as specified and as directed. 9 item no 08 : m & l for machine cut kota stone slab 20 25mm thick incl 10 mm thick rendering in cement mortar 1:4laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete asin riser of steps, skirting, dado and pillar laid over cement screed and jointedincluding dismantling of stone slab of any thickness.complete all as specified and as directed. 10 item no 09 : s & f in repair ( 18 / 19 mm thick ) laminated with high glossy finish sunmica 1 mm thick ( colour approved by engr in charge ) all sides excluding hinge side, including 5 mm wooden leaping bead ( at hinge side ) for cupboard, kitchen cabinet shutters etc complete all as specified and directed. 11 item no 10 : s & f stainless steel slip on soft closing concealed hinges for cabinet doors, smooth oprating hinges for full overlay doors and windows complete all as specified and directed. 12 item no 11 : m & l for factory made 35 mm thick flush shutters, solid core construction, with block board core and 5 mm thick plywood face panels on both side, commercial type on both sides covered face veneered decorative type etc.complete all as specified and as directed. 13 item no 12 : m & l for pressed steel door frame size 105 mm x 60 mm made of 1.25 mm thick sheet including necessary fixing lugs, hinges, lock strike plate etc., complete, all as specified. 14 item no 13 : m & l for pressed steel door frame size 125 mm x 60 mm made of 1.25 mm thick sheet including necessary fixing lugs, hinges, lock strike plate etc., complete, all as specified. 15 item no 14 : m&l for providing pcc 1:2:4, type b 0 ( using 12.5 mm graded stone aggregate ) as in filling of pressed steel door frame and holdfasts including necessary formwork etc. 16 item no 15 : s&f in stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.18mm and fixed with beeding / staples directed by engr in charge. 17 item no 16 : s&f 4mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares of any size n. exc 0.50 sqm each complete all as specified and directed by engr in charge. 18 item no 17 : s&f 4mm thickfigured glass pin head type and glazing with oil putty or wooden beads in squares n exc 0.50 sqm each pane complete all as specified and directed. 19 item no 18 : s&f in repair 20 25 mm bore cut to length as required aluminium anodised decorative curtain rails with brackets and decorative finails as selected and directed by engr in charge. 20 item no 19 : s&f in repair 600mmx450mm bevelled edge mirror of selected quality glass, 5 mm thick mounted on pvc sheet with aluminium framingfixed to wooden plugs with chromium plated screws with dome screw caps and cup washers fixed in repairs complete all as specified and as directed. 21 item no 20 : s&f in repair 15 mm dia bore bib taps, cast copper alloy chromium plated fancy type with crutch alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed.complete all as specified and as directed. 22 item no 21 : s&f in repair 15 mm dia stop valves / angle valve, cast copper alloy, fancy type chromium plated with long shank and cup ( concealed type ) screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed. 23 item no 22 : s&f in repair pvc connections 15mm size with ptmt nuts of length 600 mm all as specified and as directed. complete all as specified and as directed. 24 item no 23 : s&f cp health faucet 15 mm with flexible tube of stainless steel provided rubber hose and wall hook etccomplete as in repair all as specified and as directedcomplete all as specified and as directed. 25 item no 24 : s& f pvc ( swr ) nahani ntrap / floor trap 75 mm dia with and including cp grating all as specified and as directed complete all as specified and as directed. 26 item no 25 : s&f in repair 25 mm dia ball valves high pressure of ptmt with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed complete all as specified and as directed. 27 item no 26 : s&f in repair 15 mm dia two way angle valves / bib taps, cast copper alloy, fancy type chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed. 28 item no 27 : supply & fix in repair brass chromium plated mixer for wash hand basin for mixing hot and cold water screwed down for iron pipes suitable for 15mm bore pipe complete all as specified and directed by engr in charge. 29 item no 28 : supply & fix in repair brass chromium plated wall mixer ( 2 / 3 hole ) with provision for connection to shower rose for mixing hot and cold water screwed down for iron pipes suitable for 15mm bore pipe complete all as specified and directed by engr in charge. 30 item no 29 : s &f as in repair chromium plated shower rose 125 mm dia with 300mm cp shower arm fancy type fixed to 15mm bore pipeall as specified and directed by engr in charge. 31 item no 30 : s & fbrass chromium plated tublar towel rail 20 mm dia d type 600mm long between flanges with cp screws etc complete all as spd 32 item no 31 : s & f in repair gun metal gate valves, with iron wheel head, screwed both ends for iron pipe flange ends type fixed of 25mm dia all as spd and directed 33 item no 32 : s&f pvc waste pipe size 32 mm x 800 mm flexible with coupling for urinal / whb / sink etc. complete all as specified and directed. 34 item no. 33 : blank 35 item no 34 : s & f male brass threaded adaptor ( mta / mbta / female brass threaded adaptor ( fta / fbta ) 20 mm dia complete all as specified. 36 item no 35 : s & f supplying and laying of cpvc pipes 20 mm outer dia sdr 11 & plain cpvc sdr 11 fittings on walls / ceiling or laying in floors complete all as specified and directed by engr in charge. 37 item no 36 : s & f supplying and laying of cpvc pipes 25 mm outer dia sdr 11 & plain cpvc sdr 11 fittings on walls / ceiling or laying in floors complete all as specified and directed by engr in charge. 38 item no 36a : s & f supplying and laying of cpvc pipes 32 mm outer dia sdr 11 & plain cpvc sdr 11 fittings on walls / ceiling or laying in floors complete all as specified and directed by engr in charge. 39 item no 36b : cleaning reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, complete all as specified and directed by engr in charge. ( bars above 12 mm diameter ) . 40 item no 36c : providing & applying two coats of anti corrosive protective coating ( cbri / csir technology ) for reinforcement bars by brush. sprinkle dry sand when second coat is tacky so as to get rough surface complete all as specified and directed. 41 item no 36d : providing, mixing and applying sbr polymer ( of approved make ) modified cement mortar in proportion of 1:4 ( 1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used ) as per specifications and directions of engineer in charge.note: the pre measurement of thickness shall be done just after the surface preparation is completed and payment under ths item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated sounding / tapping with a blunt metal instruent and / or the 75 mm size cube crushing strength at the end of 28 days to be not less than 30 n / sqmm2 ) . ( 25 mm average thickness in 2 layers ) . 42 item no 37 : taking up or down steel tubing of 15 mm dia and connections, including cleaning for re fixing or removal to store 43 item no 38 : taking up or down steel tubing of 20mm dia and connections, including cleaning for re fixing or removal to store 44 item no 39 : s & f in repair rotational three layer moulded polyethylene water storage tanks ( cylinderical vertical with closed top ) capacity 1000 ltrhoisted and fixed in position all as specified and directed by engr in charge. 45 item no 40 : demolition of brick work or stone / boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. 46 item no 41 : m&l brick work using old size bricks with fly ash bricks straightor curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and directed. 47 item no 42 :taking down cement plaster any description on brick or stone walls or wall tiles etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. 48 item no 43 :m&l for rendering 10mm thick internal surfaces on fair faces of brick work in cm 1:6 as directed by engr in charge. 49 item no 44 :m&l for rendering 15mm thick external surfaces on brick / concrete in cm 1:4 finished even and fair without using extra cement with wpc 2% by wt of cement.note: wpc measured and paid separatly 50 item no 44a :m&l for rendering 10mm thick in cm 1:3 on fair faces of brick or concrete surface of ceiling finished even and smooth without using extra cement complete all as specified and directed. 51 item no 44b :m&l for two coats of distemper with acrylic distemper in newly plastered ceiling care in two layers and making the surfaces smooth & uniform including removing existing treatment complete all as specified and directed. 52 item no 44c :m&l for two coats of weather proof external acrylic emulsion paint on projected portion to wall over on external surfaces of old plastered / concrete complete all as specified and directed. 53 item no 45 :m & l for preparation of newly plastered surfaces ofwall & concrete and applying 2mm thick wall care putty including preparation complete. 54 item no 46 :m & l for preparation of oldsurfaces ofwall & concrete and applying 2mm thick wall care putty including removal of existing treated surface. complete all as specified and as directed. 55 item no 47 :m&l for applying two coat of acrylic distemper over a coat of primer inclu preparation of newplastered wall surfaes complete all as specified and as directed. 56 item no 48 :m&l for applying two coat of acrylic distempe as in ceiling incl removal of existing treatment of old treated ceiling surfaces complete all as specified and as directed. 57 item no 49 :m&l for 2 coatsweather proof external acrylic emultion paint over a coat of primerincluding preparation of newly plastered complete all as specified and directed 58 item no 50 :demolition of concrete in ground floors and pavings including floor tiles n exc 15 cm thickness ( below or above ground level ) complete all as specified and as directed. 59 item no 51 :m & l for cement concrete type b 0, 1:2:4 ( 12.5 mm graded aggregate ) , 25 mm thick in flooring etc complete all specified and as directed 60 item no 52 :m & l for 75 mm thick cement concrete type c 1, 1:3:6 ( 20mm graded aggregate ) as in sub base complete all as specified and as directed. 61 item no 53 :m&l for granite ( any type ) work ( table rubbed and polished ) 18 to 20 mm thick in working platform and like including cutting for sink etc. in cement mortar ( 1:4 ) including rounding of edges and pointing in white cement ( 1:2 ) using marble dust with admixture of pigment to match.complete all as specified. 62 item no 54 :m & l two coats of synthetic enamel painting on steel surfaces exc 10 cm width or girth over one coat of red oxide primer including preparation of new steel surfaces. 63 item no 55 :m & l two coats of synthetic enamel painting on wooden surfaces exc 10 cm width or girthover one coat of pink primer. 64 item no 56 :m & l for tmt reinforcement bars 8 mm dia & over cut to length, bent to shape required, including crancking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire ( annealed ) not less than 0.9 mm dia or securing with clips complete 65 item no 57 :m&l rcc type b 1, 1:2:4 ( using 20 mm graded stone aggregate ) in slabs, cantilever or supported on walls and small works like cubes etc.complete all as specified and as directed. 66 item no 57 a :demolition of cement concrete ( reinforced ) n ground floor and paving n exc 150 mm thick ( below or above ground level ) complete all as specified and as directed. ( reinforcement cut as required to facilitate demolition ) . 67 item no 58 :m&l for pvc ( swr ) pipessingle socketed, in any length with rubber ring joints, laid in trenches or in floors or walls of 110 mm bore of pipe etc complete all as specified and directed. 68 item no 59 :m&l for pvc ( swr ) pipessingle socketed, in any length with rubber ring joints, laid in trenches or in floors or walls of 75 mm bore of pipe etc complete all as specified and directed 69 item no 60 :demolition and breaking up drain pipes upto 100 mm dia ( salt glazed ware, ac or reinforced concrete ) set in cement mortar complete all as specified and as directed. 70 item no 61 :s&f pvc ( swr ) bends isi marked any radius of 110 mm borewithaccess door complete all as specified and directed. 71 item no 62 :s&f pvc ( swr ) bends isi marked any radius of 75 mm borewithaccess door complete all as specified and directed. 72 item no 63 :s&f pvc ( swr ) junction single, ( single t ) equal or un equal of 110 mm bore of pipe with access door complete all as specified and directed 73 item no 64 :s & f of pvc ( swr ) vent cowl for 110 mm bore pipe complete all as specified and as directed. 74 item no 65 :s&f aluminium handles cast type anodised handles, d shape of size 150mm complete. isi marked 75 item no 66 :s & f as in repairalluminum alloy, anodised, cast type or extruded section, sliding door bolt with hasp & staple ( bolt type ) with fixing clips and bolts and 250 mm long complete all as specified. 76 item no 66 a :s & f as in repairalluminum alloy, anodised, cast type or extruded section, sliding door bolt with hasp & staple ( bolt type ) with fixing clips and bolts and 300 mm long complete all as specified. 77 item no 67 :s & f in repair sinks made of stainless steel 1.00mm thick with waste coupling with all necessary fittings, kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and as directed. 78 item no 68 :s & f in repair vitreous china wash basin oval shape white flat back size 550 x 400mm with waste coupling with all necessary fittings, chain & plug and porcelain stopper but including brackets or fixed to walls with anchor fastnersall as specified and directed by engr in charge. 79 item no 68 a :s & f vitreous china wash basin oval type of size 560 x 400 x 205 mm counter top and supply of waste pipe and cp waste coupling 32 mm dia completeall as specified and directed. 80 item no 69 :s & f of vitreous china wash down water closet pan ( pedestal pattern ) , white including fixing bolts, but excuding flushing cistern and flush pipe complete. complete all as specified and as directed. 81 item no 69 a :s & f of vitreous china wash down water closet of cascade nxt wall hung of size 670x365x770mm ( including cover ) including flushing cistern & seat cover including all required fitting complete all as specified and as directed. 82 item no 70 :s & f as in repair10 litre pvc valveless, syphonic action type, dual type flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete. 83 item no 71 :s & f as in repair soft closing white seat cover forewc incl accessories complete all as spd 84 item no 72 :m & l for repair of sunken slab as under : ( a ) m & l for application of 1:3 cement – sand mortar, mixed with sika latex emulsion ( 300 gram in 1 kg cement ) , as a coving at the corners of floor and the vertical surface in the sunken area and between floor and walls in the remaining area. ( b ) m & l for application of sika top seal 109hi @ 2.20 kg per sqm each coat or as per manufacture instruction– acrylic based, ready to use, cementitious, water proof coating onto the prepared surface in a continuous film on the floor of the sunken area, taking the coating over the vertical surfaces on to the floor and over the coving on to the wall ( before tiling ) to at least 300mm above the final finished floor level. the coating shall also be continued on to the inner surfaces of the pipe penetration holes. two coats shall be applied & fiber glass cloth to be laid in between coats. ( c ) m & l for application of sikagard 694 f ( i ) @ 100 gram per sqm or as per manufacture instruction, a moisture insensitive epoxy putty in a continuous, 10mm thick gasket around the pipes to a width of approximately 15mm. ( d ) m & l for application of protective screed concrete at a desired thickness admixed with sika cim pink @ 100 gram per sqm or as per manufacturer instruction 85 item no 73 :s & f stainless steel but hinges, medium weight cold rolled of size 100 mm . 86 item no 74 :s & f 150 mm long aluminium anodised barrel tower boltof extruded section 87 item no 75 :s & f 200 mm long aluminium anodised barrel tower boltof extruded section 88 item no 76 :taking down chowkhats or frames not exc 1.5 sqm ( without taking shutters from the frame ) . 89 item no 77 :taking down chowkhats for frames exc 1.5 sqm but n exc 4.00 sqm ( without taking shutters from the frame ) . 90 item no 78 :s & f 35 mm thick 2nd class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc ( without sash bars ) edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc fitted to chowkhats for doors etc complete. 91 item no 79 :s & f solid pvc door frame of size 50mm x 47mm made out of 5mm single side prelam pvc sheet & edges will be painted to match with prelam sheet reinforced with m.s. square tube, suppling & fixing in opening as per specification & drawing complete all as specified and as directed. 92 item no 80 :s & f solid pvc factory madedoor shutter of 30mm ( style ) consisting of frame made out of ms tubes for top bottom rails ms frame shall be covered with heat moulded plain coloured pvc c channel having a pvc sheet strip 20mm width stuck inside with solvent cement for stilesa and plain coloured pvc sheets for top rail, lock & bottom rail on either sides & as gap insert for top rail & bottom rail panelling ofplain colour pvc sheet to be fitted in the ms frame welded / sealed to the stiles & rails with suitable pvc sheet beeding and jointed together with solvent cement as pere specification and drawing complete all as specified and as directed. 93 item no 81 :m&l for providing water proofing treatment over cleaned roof surfaces with super thermo app modified water froofing membran comprssing of following for non approachable roof: ( i ) removal of existing roof treatment and cleaning sweeping and washing and down with water to remove all dust etc from plastred roof surfaces / wall and filling of crack with sealing compound etc. ( ii ) bitumen based primer conforming to is 3384 1965 at 0.30 kg per sqm. ( iii ) one layer of super thermo app modified water proofing membran with non polyster reinforcement of make ( m / s stp texsa ltd / hyperplus membrane of m / s iwl india ltd. m / s stp and tikki tar ltd ) 3mm thick and minimum weight @ 3.50 kg / sqm laid with gas torch and fasted on roof surfaces with roller. the over laps shall be sealed by flame including vertical surfaces after cutting necessary grooving and making good with pcc gola 1:2:4 type b1 etc adhere to bitumen all as per manufacturer instructions. ( iv ) applying two coat of aluminium paint @ 0.20 kg / sqm per coat over bitumen layers as per manufacturer instruction ( application including side lap overlaps shall be provided not less than 10cm and jointed sealed with torch as per manufacturer instruction specification. 94 item no 81 a :m & l for machine cut and polished cement concrete tile factory made with grey cement without pigment of size 250 mm x 250 mm x 22 / 20 mm thick laid in neat cement slurry over and including 20 mm thick screed bed in cm 1:4 mixed chemical compound as per manufacturer instructions and tile properly laid with 3 mm wide joint filled with chemical like tile grout as per manufacturer instructions complete all as specified and directed. 95 item no 82 :supply only liquid water proofing compound isi marked. 96 item no 83 :m & l for machine pressed precast conctete interlocking paver block any shape and size confirming to is 15658 2006 of 60 mm thickness m 35 grade with grey cement and no pigment complete all as specified and directed. 97 item no 84 :sand filling under floors for cushioning ofincluding watering and consolidation 98 item no 85 :s&f mild steel framed works such as grills, gratings, etc, with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work for portions framed and hung as gates, including pintle hinges, stops, hand made sliding bolts, etc conforming to fe 290 gde e 165. 99 item no 86 :m & l for providing, cement concrete type b1, 1:2:4 ( using 20 mm graded stone aggregate ) in cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary form work all as specified and as directed 100 item no 87 :m & l formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick for rough finished flat surfaces ( horizontal or sloping ) all as specified and as directed 101 item no 88 : s & f of supply and fixing factory made upvc white colour three track three panels sliding window with fly proof s.s wire mesh ( two nos. glazed & one no. wire mesh panels ) upto 1.50m height made of ( big series ) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. ( area of window above 1.75 sqm ) comprising of upvc multi chambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length ( shape & sizeaccording to upvc profile ) , appropriate dimension of upvc extruded glazing beads and upvc extruded interlocks, epdm gasket, wool pile, zinc alloy ( white powder coated ) touch locks with hook, zinc alloy body with single nylon rollers ( weight bearing capacity to be 40 kg ) , g.i fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed by engineer in charge. ( glass or wiremesh shall be paid separately ) note: for upvc frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 102 item no 89 : supply and fixing factory made upvc white colour fixed glazed window / ventilator made of ( small series ) frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension ( area upto 0.75 sqm. ) comprising of upvc multi chambered frame and mullion ( where ever required ) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length ( shape & size according to upvc profile ) , upvc extruded glazing beads of appropriate dimension, epdm gasket, g.i. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. profile of frame shall be mitred cut and fusion welded at all corners, mullion ( if required ) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of engineer in charge. ( glass shall be paid separately ) . note: for upvc frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.complete all as specified and as directed. 103 item no 90 : s & f powder coated aluminium frame / shutters for windows, ventilators sliding / openable etc icluding joining cleat for fixing, locking arrangement, rubber beading, screws, etc complete all as specified. note : ( i ) glazing and wire mesh shall be measured and paid separetely only as the labour element included in the relavent item. ( ii ) item shall be paid as per weight of aluminium section ( iii ) the rate quoted shall be inclusive of the cost of neoprene beading, glazing pin, screws and powder coated fittings such as locking arraangement etc as required, which shall not be measured for arriving the weight ( iv ) the rate shall also be inclusive of complete packing with silicon gel around contacting surfaces of aluminium work, and including matching the existing. note: aluminium windowchowkhat and shutters are to be made as per td / issued by hq chief engineer jabalpur zone. 104 item no 91 : dismantling wrought iron or mild steel work of any description such as mild steel window / ventilator complete all as specified and as directed. 105 item no. 92 : taking down copper / aluminium point wiring ( light, fan, bell, socket or power ) complete includingfittings etc. romoving meterials to store for keeping i safe custody or for taking credit ( credit a for above items should be made as per condition seperately ) and making good distrubed surfaces of walls, floors etc complete all as specified and directed at site by engineer in charge. 106 item no. 93 : taking down old / unserviceable distribution board by disconnection of electric connection carefully spn dbs / tpn dbs / main switch including old unserviceable mccbs / mcbs, isolators, etc and making good to disturbed surface complete all as specified and directed by engineer in charge. 107 item no. 94 : taking down carefully copper / aluminium sub main wiring of any size from surface / concealed / existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed. 108 item no. 95 : taking down existing geyser of any capacity after disconnecting all necessary electrical and water supply connections and deposit to mes store yard of age e / m no ii complete all as specified and directed. 109 item no. 96 : taking down ceiling fan / exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan blsdes and deposit to mes store yard of age e / m complete all as specified and directed. 110 item no. 97 : taking down existing single phase electric energy meter of any capacity after disconnecting all necessary electrical connections and deposit to mes store yard of age e / m complete all as specified and directed. 111 item no. 98 : m&l for point wiring with 1.5 sq mm single core pvc insulated unsheathed frlsh cable multi stranded copper conductor cable in and including concealed rigid non metallic pvc conduit heavy duty grade of size 20 / 25mm isi marked inclusive of tees, bend, elbows etc upto and including sunk in anodized pressed steel box for housing switch socket etc with white laminated 3 mm thick hylam sheet cover isi marked of suitable size complete including pvc insulated multi stranded copper conductor 1.5 sq mm frlsh cable as earth wire to common earth dolly for connection to ceiling rose to earth terminal including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed by engineer in charge: 112 ( a ) one light point controlled by one, one way switch 5 amps 113 ( b ) one fan point / exhaust fan point controlled by one, one way switch 5 amps and regulator 114 ( c ) one light point controlled by one, two 2 way switches 5 amps 115 ( d ) one 3 pin 5 amps switch socket outlet point controlled by one switch on the same board. 116 ( e ) one 3 pin 5 amps switch socket outlet point controlled by one switch on the independent board 117 ( f ) one bell point controlled by one, bell switch 5 amps 118 item no. 99 : all as per item no 98 here in before but with 2.50 sq mm single core copper of multistranded frlsh pvc insulated un sheathed 1100 volts grade for 5 / 15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor frlsh pvc wire as earth continuity conductor along with wiring and connecting to the common earth dolly. 119 item no. 100 : m&l for point wiring using approved colour coding as per is, with multistranded copper conductor1.5 sqmm ( nominal area ) , two single core pvc insulated and unsheathed frlsh cable 1100 volts grade isi 694 marked drawn through in and including heavy duty pvc concealed conduit of white / ivory colour including all accessories after chasing in wall / ceiling etc, heavy duty isi marked, with gi sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable size for modular switches, including pvc insulated multistranded copper conductor 1.5 sqmm ( nominal area ) single core frlsh cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for following: 120 ( a ) one light point controlled by one, one way switch 5 amps 121 ( b ) one fan point / exhaust fan point controlled by one, one way switch 5 amps and regulator 122 ( c ) one light point controlled by one, two way switches 5 amps 123 ( d ) one 3 point 5 amps switch socket outlet point controlled by one switch on the same board. 124 ( e ) one 3 pin 5 amps switch socket outlet point controlled by one switch on the independent board 125 ( f ) one bell point controlled by one, bell switch 5 amps 126 item no. 101 : description all as per item no 100 here in before but using 2.50 sq mm single core copper conductor cable of multistranded frlsh pvc insulated un sheathed 1100 volts grade for 5 / 15 amps switch socket combination point including necessary running of 2.5 sq mm copper conductor frlsh pvc wire as earth continuity conductor along with wiring and connecting to the common earth dolly. 127 item no. 102 : description all as per item no 100 here in before but using 4.0 sq mm single core copper conductor frls cable of multistranded pvc insulated un sheathed 1100 volts grade for 5 / 15 amps switch socket cobmination point including necessary running of 4.0 sq mm copper conductor frls cable as earth continuity conductor along with wiring and connecting to the common earth dolly. ( for ac ) 128 item no. 103 : s&f switch piano flush type single pole, 5 amp, 230 volts complete all as specified and directed. 129 item no. 104 : s&f switch piano flush type single pole, 15 amp, 230 volts complete all as specified and directed. 130 item no. 105 : s&f switch piano flush type 2 way switch 5 amp, 230 volts complete all as specified and directed. 131 item no. 106 : s&f switch bell push piano type 5 amp, 230 volts complete all as specified and directed. 132 item no. 107 : s&f socket outlet 2 in 1, 5pin, 5amp, 230 volts complete all as specified and directed. 133 item no. 108 : s&f socket outlet 2 in 1, 5pin, 5 / 15amp, 230 volts complete all as specified and directed. 134 item no. 109 : supply and fixing ceiling rose surface bakelite 3 terminals, isi marked for batten fitting complete all as specified. 135 item no. 110 : s&f stepped type electronic fan regulator flush type complete all as specified and directed by engineer in charge. 136 item no. 111 : s&f for moduler switch piano flush type single pole, one way and 5 / 6 amp single module complete all as specified and directed. 137 item no. 112 : s&f for moduler switch piano flush type single pole, one way and 15 / 16 amp single module complete all as specified and directed. 138 item no. 113 : s&f for moduler switch piano flush type single pole, two way and 5 / 6 amp single module complete all as specified and directed. 139 item no. 114 : s&f for moduler socket outlet multipurpose having provision for 3 pin, 5 / 6 amp and 2 pin, 5 / 6 amp, 2 module piano flush type complete all as specified and directed. 140 item no. 115 : s&f for moduler socket outlet multipurpose having provision for 3 pin, 15 / 16 amp and 3 pin, 5 / 6 amp, 2 module piano flush type complete all as specified and directed. 141 item no. 116 : s&f for module step type fan regulator 120 watt 2 module suitable for 230 volt 50 hz ac supply complete all as specified and directed. 142 item no. 117 : s&f for bell push modular 6 amps single module complete all as specified. 143 item no. 118 : supply and fixing lamp holder pcv / polycarbonate type with back plate suitable for batten / slating fitting complete all as specified and directed by engineer in charge. 144 item no. 119 : s&f for bell electric ding dong type suitable for operation on 230 volt 50 hz ac supply complete all as specified and directed by engineer in charge. 145 item no. 120 : s&f for modular type tv socket out letcomplete all as specified and directed. 146 item no. 121 : m&l for sub main wiring with approved colour coding as per is with four single core pvc insulated frlsh cable with stranded copper conductor of 6 sq mm nominal area and drawing into suitable size of pvc non metallic rigid heavy duty pvc conduit of white / ivory colour and its accessaries isi marked heavy duty of suitable size including concealed in wall etc one run of conductor frlsh cable with 6.0 sqmm ( nominal area ) stranded copper conductor frlsh cable as earth wire complete all as specified and as directed. note: four runs of 6 sqmm cable for phase and neutral and one run of 6 sqmm cable for earthing and one run of pvc conduit will be measured as one unit. 147 item no. 122 : m&l for sub main wiring with approved colour coding as per is with two single core pvc insulated frlsh cable with stranded copper conductor of 6 sqmm nominal area and drawing into suitable size of pvc non metallic rigid heavy duty pvc conduit of white / ivory colour and its accessaries isi marked heavy duty of suitable size including concealed in wall etc one run of pvc insulated with 6.0 sqmm ( nominal area ) stranded copper conductor frlsh cable as earth wire complete all as specified and as directed. note: two runs of 6 sqmm cable for phase and neutral and one run of 6 sqmm cable for earthing and one run of pvc conduit will be measured as one unit. 148 item no. 123 : supply and fixing for sheet metal enclosure mcbdb tpn 4 way vertical type with 200amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the dbs in wall by cutting the brick / stone masonary etc and making good of distributed surface to match with existing colour of wall complete all as specified and as direced. 149 item no. 124 : supply and fixing for sheet metal enclosure mcbdb spn 8 way with 200 amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the dbs in wall by cutting the brick / stone masonary etc and making good of distributed surface to match with existing colour of wall complete all as specified and as direced. 150 item no. 125 : supply and fixing for mcb tripple pole and neutral rated capacity 63 amps 415 volts breaking capacity 10 ka, c curve complete all as specified and as direced. 151 item no. 126 : supply and fixing for mcb tripple pole and neutral rated capacity 32 amps 240 volts breaking capacity 10 ka, c curve complete all as specified and as direced. 152 item no. 127 : supply and fixing for mcb single pole rated capacity 5 to 32 amps 240 volts breaking capacity 10 ka, c curve complete all as specified and as direced. 153 item no. 128 : supply and fixing for metal clad box suitable for 230 volts 50 hz ac supply three pin with mcb sp 20 / 32 ampsremoval of old unserviceable one complete all as specified and as direced. 154 item no. 129 : s&f for water heater storage type ( geyser ) vertical / horizental type as per site requirement with inner container of capacity 25 ltrs, electrically operated, ac 230 volts, bee 5 star rated with all accesseries such as safety valve, thermostate, nrv, isi marked including 04 nos of hold fashner nuts required suitable size fixed in brick wall, including 02 no steel braided pipe 450 mm length pvc connection pipe hot & cold for officers jcos and or accn complete all as specified and as directed. 155 item no. 130 : s & f ceiling fans complete with blades, down rods, and accessories, 230 v, 1200 mm sweep. min air adelivery 210 cfm with service value 6.0 bee. five star rated with brushless direct current motor ( bldc ) complete all as specified and as directed. 156 item no. 131 : labour only for refixing the ceiling fan / exhaust fan obtained from dismantling with replacement of unsv 3 core pvc insulated pvc sheated 3 core multistranded copper conductor cable of size 23 / 0.193 from ceiling rose to fan terminal including over hauling the fan, painting of ceiling fans complete two coats synthetic enamel paint by spraying including filling cavities with filler after cleaning all dust etc. complete all as specified and as directed. 157 item no. 132 : s & f for highly efficient led bulbs 10 w with luminous efficacy not less than 105 lm / watt, used as a ready replacement for existing old gls / cfl direct fit lamp, in b 22 cap of complete all asspecified and directed. 158 item no. 133 : s&f for decorative wall mounted luminaire made out of polycarbonate with unbreakable globe suitable for led bulb and provision of led bulb 10 w with luminous efficacy not less than 105 lm / watt, complete all as specified and as directed. 159 item no. 134 : s&f for led 10 watts batten luminous efficacy having not less than 120 lm / watt aluminium extruded with decorative end caps complete all as specified and as directed. 160 item no. 135 : s & f energy saving new generation 10 watts led, luminous efficacy having not less than 110 lm / watt bulk head fitting ip 65 luminaire with opel diffuser pre wired, with warranty option of 5 years from date of installation and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23 / 0.193 form ceiling rose to fitting including led bulb complete all as specified and directed. 161 item no. 136 : s & f for wall mounted led tube light fitting 20 watts led luminous efficacy having not less than 120 lm / watt batten for surface mounted, anodized extrded aluminium housing, high transmissitivity diffuser, high lumen output box type fitting, 230 volts and intregated electronic driver connector block etc with warranty option of years from date of installation complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23 / 0.193 from ceiling rose to fitting complete all as specified and as directed. 162 item no. 137 : s & f for energy saving new generation environmental friendly long life versatile presure die cast aluminium ip 66 for security light fitting luminaire with high power leds as light source and electronic driver of capacity 25 watts, luminous efficacy having not less than 110 lumen / watt with pre wired and necessary mounting arrangements andprovision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia gi pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as directed by engineer in charge. 163 item no. 138 : s&f for energy effcient exhaust fan of 230 mm sweep made of metal body ventil air ds type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of pvc flexible copper cable of size 23 / 0.0076 two core from ceiling rose to exhaust fan for connection and making suitable size of hole to existing brick wall for fan base complete all as specified and directed. ( note: cost of suitable opening wall for fixing exhaust fan is deemed to be included in overall rate quoted ) . 164 item no. 139 : s&f for pvc non metallic rigid conduit isi marked heavy duty white / ivory colour and its accessories heavy duty isi marked of size 20 mm dia for lan, telephone and tv connections including cutting chases and making good disturbed surfaces to match with existing finish with plaster complete all as specified and directed. 165 item no. 140 : supply, installation, commissioning and testing indoor type lt wall mounting panel board of minimum size 1.50m ( height ) x 1.20 m ( breath ) x 0.30 m ( depth ) factory made cpri approved panel, weather, dust & vermin proof indoor, double door, front openable, including four comparment for fixing of four nos three phase kwh meter, one no single phase meter and mcb tpn and providing glass view for reading of meter and providing rubber / pvc gasket of suitable size all sides of door, with copper strip / wire busbar of suitable size to mccb input and mccb / mcb output of suitable length for connection of cable from main busbar, made out of 2.00 mm thick mild steel crca sheet with suitable size angle iron supporting frame including applying two coats of powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfaces suitable for 3 phase 4 wire system 415 / 440 volts grade including complete internal wiring with 10 sqmm copper wire and connections of all outgoing / incomming existing cable of any size complete all as specified and directed by engineer in charge. ( for officers g+1 md accn ) incomming ( a ) copper strip busbar of size 30 x 5 mm wrapped with pvc sleeves with maintained the colour code and provision of making holes with copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends = 04 nos 166 ( b ) mccb ip 44 and ip 66 / 67 protection, 4 pole, 415 volts, lcu=25 ka breaking capacity, rating 100 amps, adjustable thermal magnetic release including all fixing accessories with both ends spreader links 01 no ( c ) digital voltmeter of range ( 0 500 ) volts, flush mounting type of size 100mm x 100mm ( 4x4 ) square dial with selector switch 01 no. ( d ) led neon indicator lamp ( ryb ) with holder, 230 / 250 volts, ac 01 set ( set of three ) outgoing ( a ) mcb, tripple pole & neutral, 40 amps, 415 volts, c curve, 10 ka complete all as specified and directed 4 nos ( officers accn ) ( b ) mcb, single pole & neutral, 10 amps, 240 volts, c curve, 10 ka complete all as specified and directed 4 nos ( stair case lighting ) ( c ) fixing only serviceable existing electric meter 01 no ( obtained from demolition / dismantling ) 167 ( d ) supply and fixing of three phase electronic energy meter accuracy class 1.0, 240v, with in home display 10 60a, 3 nos self locking meter seal, lcd display with with optical part, anti temper features, lcd test, serial no. date, rtc, cumulative kwh, last bill kwh, instranteous load, last bill md, instantaneous kw, volts, pf, hz, md, total tamper count, self billing code, battery backup in absence of power for display active energy kwh, including all incoming and out going connections 04 nos 168 item no. 141 : supply, installation, commissioning and testing indoor type lt wall mounting panel board of minimum size 1.20m ( height ) x 1.20 m ( breath ) x 0.30 m ( depth ) factory made cpri approved panel, weather, dust & vermin proof indoor, double door, front openable, including four comparment for fixing of five nos single phase meterand mcb and providing glass view for reading of meter and providing rubber / pvc gasket of suitable size all sides of door, with copper copper busbar wrapped with pvc tape / sleeves with maintained the colour code and copper strip / wire busbar of suitable size to mccb input and mccb / mcb output of suitable length for connection of cable from main busbar, made out of 2.00 mm thick mild steel crca sheet with suitable size angle iron supporting frame including applying two coats of powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfaces suitable for 3 phase 4 wire system 415 / 440 volts grade including complete internal wiring with 1.5 sqmm copper wire and connections of all outgoing / incomming existing cable of any size complete all as specified and directed by engineer in charge. ( for : g+1 jco, or, md accn ) incomming ( a ) copper strip busbar of size 25 x 5 mm wrapped with pvc sleeves with maintained the colour code and provision of making holes with copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends = 04 nos 169 ( b ) mccb ip 44 and ip 66 / 67 protection, 4 pole, 415 volts, lcu=25 ka breaking capacity, rating 63 amps, adjustable thermal magnetic release including all fixing accessories with both ends spreader links 01 no ( c ) digital voltmeter of range ( 0 500 ) volts, flush mounting type of size 100mm x 100mm ( 4x4 ) square dial with selector switch 01 no. ( d ) led neon indicator lamp ( ryb ) with holder, 230 / 250 volts, ac 01 set ( set of three ) outgoing ( a ) mcb, single pole & neutral, 40 amps, 240 volts, c curve, 10 ka complete all as specified and directed 6 nos ( b ) fixing only serviceable existing electric meter 05 no ( obtained from demolition / dismantling ) 170 item no. 142 : taking down existing old extg unserviceable lt under ground / service cable of any description and sizecomplete all as specified and directed. 171 item no. 143 : supply and lay cable xlpe insulated screened pvc bedded, galvanized steel strip or wire armoured, electric power cables ( heavy duty ) 1100 volts grade with stranded aluminium conductor of following sizescomplete all as specified and directed 172 ( a ) 3.5 core x 35 sqmm 173 ( b ) 4 core x 16 sqmm 174 item no.144 : excavation in trenches n exc 1.5m wide n exc 1.5m in depth for foundation etc. for laying pipe lines and cablesand getting out as in soft / loose soil complete all as specified and directed. 175 item no. 145 : returning filling in, including spreading, levelling, watering and ramming in layers not exc 25cm in soft / loose soil complete all as specified and directed. 176 item no.146 : removing excavated material to a distance not exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed. 177 item no.147 : supply and laying river bed fine sand in trenches / ducts 8 cm under cable and 15 cm above the cable for cushioning / protection to cable including spreading, levelling and get thick 18 cm after hand punning complete all as specified and directed at site. 178 item no 148 : supply and laying for brick of common burnt clay, sub class b old size laid flat and dry on cables as in cable protection in trenches over cables perpendicular to direction of cales abutting each other complete all as specified and directed. 179 item no. 149 : m&l for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6mm thick buried directly in ground ( earth pit not less than 2.25 m deep below ground level ) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to gi earth wire 4mm dia by means of bolts, nuts, washers of galvanized iron or steel all as shown in electrical plate no 3 and testing on completionincluding adequate charcoal dust comman salt necessary excavation earth work pcc ( 1:3:6 ) type c 1 pit with precast rcc cover slab 40 mm thick in pcc ( 1:2:4 ) type b 1 reinforced with 6 mm dia ms bars @ 100 mm c / c both ways with funnel wire funel wire mesh and 20 mm dia gi pipe medium grade as watering pipe and connected to earthing point complete all as specified and directed. 180 item no 150 : galvanised iron steel tubes, isi marked light grade of size 40mm bore for cable protection along the poles under road under drains complete all as specified and as directed. 181 schedule a ( schedule of credit ) schedule of credit rs 784007.00 ( minus ) inserted by the mes. ( note : credit amount shall be deducted manually to arrive net bid amount ) ...

Uttar Pradesh Projects Corporation Limited - Bihar

42836281 construction of phase b works at jnv madhubani ( bihar ) 1 guest house ( civil works ) 2 earth work 3 earth work in excavation by mechanical means ( hydraulic excavator ) / manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 sqm on plan ) , including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 4 all kinds of soil 5 filling available excavated earth ( excluding rock ) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 6 supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 7 excavating, supplying and filling of local earth ( including royalty ) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 8 concrete work 9 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 10 1:5:10 ( 1 cement : 5 coarse sand ( zone iii ) : 10 graded stone aggregate 40 mm nominal size ) 11 providing and laying cement concrete in retaining walls, return walls, walls ( any thickness ) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : 12 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) . 13 providing and laying damp proof course 40mm thick with cement concrete 1:2:4 ( 1 cement : 2 coarse sand ( zone iii ) : 4 graded stone aggregate 12.5mm nominal size ) 14 providing & applying a coat of residual petroleum bitumen of grade of vg 10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 15 making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 16 reinforcedcementconcrete 17 centering and shuttering including strutting, propping etc. and removal of form for all heights: 18 foundations, footings, bases of columns, etc. for mass concrete 19 columns, pillars, piers, abutments, posts and struts 20 small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like 21 edges of slabs and breaks in floors and walls 22 under 20 cms wide 23 suspended floors, roofs, landings, balconies and access platform. 24 lintels, beams, plinth beams, girders, bressumers and cantilevers. 25 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 26 thermo mechanically treated bars of grade fe 500d or more. 27 add for plaster drip course / groove in plastered surface or moulding to r.c.c. projections. 28 providing and laying in position machine batched and machine mixed design mix m 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per is: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of engineer in charge.“ ( note : cement content considered in this item is @ 330 kg / cum.“excess / less cement used as per design mix is payable / recoverable separately ) . 29 all works upto plinth level 30 all works above plinth level upto floor v level 31 brick work 32 brick work with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 in foundation and plinth in: 33 cement mortar 1:6 ( 1 cement : 6 coarse sand ) 34 providing and laying autoclaved aerated cement blocks masonry with 150mm / 230mm / 300 mm thick aac blocks in super structure above plinth level up to floor v level with rcc band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of engineer in charge. ( the payment of rcc band and reinforcement shall be made for seperately ) . 35 half brick masonry with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 in superstructure above plinth level up to floor v level. 36 cement mortar 1:4 ( 1 cement :4 coarse sand ) 37 extra for providing and placing in position 2 nos 6mm dia. m.s. bars at every third course of half brick masonry. 38 brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 including grouting with cement mortar 1:4 ( 1 cement : 4 fine sand ) . 39 marble work 40 providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand ) , joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 41 granite of any colour and shade 42 area of slab over 0.50 sqm 43 providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer in charge. 44 granite work 45 extra for fixing marble / granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. 46 extra for providing opening of required size & shape for wash basin / kitchen sink in kitchen platform, vanity counter and similar location in marble / granite / stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 47 wood work & pvc work 48 providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately ) . 49 second class teak wood 50 extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. ( area of opening for glass panes excluding portion inside rebate shall be measured ) . 51 providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 52 25 mm thick ( for cupboard ) including isi marked nickel plated bright finished m.s. piano hinges is : 3818 marked with necessary screws 53 providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) non decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 54 35 mm thick including isi marked stainless steel butt hinges with necessary screws 55 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters ( over all area of door shutter to be measured ) . 56 providing and fixing wire gauge shutters using galvanized m.s. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 57 35 mm thick shutters 58 kiln seasoned and chemically treated hollock wood 59 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coat with approved steel primer all complete. 60 fixed to steel windows by welding 61 providing and fixing fly proof galvanized m.s. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. 62 with 12 mm mild steel u beading 63 providing and fixing oxidised m.s. casement stays ( straight peg type ) with necessary screws etc. complete. 64 250 mm weighing not less than 150 gms 65 providing and fixing aluminium sliding door bolts, isi marked anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) , transparent or dyed to required colour or shade, with nuts and screws etc. complete : 66 250x16 mm 67 providing and fixing aluminium tower bolts, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 68 200x10 mm 69 providing and fixing aluminium handles, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 70 125 mm 71 providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. 72 twin rubber stopper 73 providing & fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to is : 2046 type s, including cost of adhesive of approved quality. 74 1.5 mm thick 75 providing and fixing cup board shutters with 25 mm thick veneered particle board is : 3097 marked, exterior grade ( grade i ) , of approved make, including iind class teak wood lipping of 25 mm wide x 12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of engineer in charge. 76 with decorative veneering on one side and commercial veneering on other side 77 providing and fixing factory made upvc white colour sliding glazed window upto 1.50 m in height dimension comprising of upvc multi chambered frame with in built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length ( shape & size according to upvc profile ) , appropriate dimension of upvc extruded glazing beads and upvc extruded interlocks, epdm gasket, wool pile, zinc alloy ( white powder coated ) touch locks with hook, zinc alloy body with single nylon rollers ( weight bearing capacity to be 40 kg ) , g.i fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of engineer in charge. ( single / double glass panes, wire mesh and silicon sealent shall be paid separately ) . variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 78 three track three panels sliding window with fly proof s.s wire mesh ( two nos. glazed & one no. wire mesh panels ) made of ( big series ) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. ( area of window above 1.75 sqm ) . 79 providing and fixing isi marked oxidised m.s. single acting spring hingeswith necessary screws etc. complete : 80 150 mm 81 providing and fixing oxidised m.s. hasp and staple ( safety type ) conforming to is : 363 with necessary screws etc. complete : 82 90 mm 83 providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 84 75 mm 85 providing and fixing wooden moulded corner beading of triangular shape to the junction of panelling etc. with iron screws, plugs and priming coat on unexposed surface etc. complete 2nd class teak wood. 86 50x50 mm ( base and height ) 87 float glass panes 88 4.0 mm thick glass panes ( weight not less than 10 kg / sqm ) . 89 steel work 90 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side / top / centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, ( sectional weight of only steel members shall be measured for payment ) . 91 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) 92 providing and fixing t iron frames for doors, windows and ventilators of mild steel tee sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 93 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) 94 providing and fixing circular / hexagonal cast iron or m.s. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick m.s. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron / m.s. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. clamp shall be made of 12 mm dia m.s. bar bent to shape as per standard drawing. 95 providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 96 4.0 mm thick glass panes 97 flooring 98 kota stone slab flooring over 20 mm ( average ) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 ( 1 cement : 4 coarse sand ) : 99 25 mm thick. 100 providing and fixing glass strips in joints of terrazo / cement concrete floors. 101 40 mm wide and 4 mm thick 102 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm ( average ) thick cement mortar 1:3 ( 1 cement: 3 coarse sand ) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 103 extra for pre finished nosing in treads of steps of kota stone / sand stone slab. 104 extra for kota stone / sand stone in treads of steps and risers using single length up to 1.05 metre. 105 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 106 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3kg / sqm including pointing the joints with white cement and matching pigment etc., complete. 107 providing and laying vitrified floor tiles in different sizes ( thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3kg / sqm including grouting the joints with white cement and matching pigments etc., complete. 108 size of tile 600x600 mm 109 providing and laying vitrified tiles in different sizes ( thickness to be specified by manufacturer ) , with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 ( 1 cement: 3 coarse sand ) , jointing with grey cement slurry @ 3.3kg / sqm including grouting the joint with white cement & matching pigments etc. complete. 110 size of tile 600x600 mm 111 roofing 112 providing and laying brick tiles over mumty roofs, grouted with cement mortar 1:3 ( 1 cement : 3 fine sand ) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 ( 1 cement : 3 fine sand ) and finished neat. 113 with common burnt clay f.p.s. ( non modular ) brick tilesof class designation 10 114 making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size ) over p.v.c. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 ( 1 cement : 3 coarse sand ) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 115 finishing 116 12 mm cement plaster of mix 117 1:6 ( 1 cement: 6 coarse sand ) 118 15 mm cement plaster on rough side of single or half brick wall of mix: 119 1:6 ( 1 cement: 6 coarse sand ) 120 cement plaster 1:3 ( 1 cement: 3 coarse sand ) finished with a floating coat of neat cement. 121 20 mm cement plaster 122 6mm cement plaster of mix 123 1:3 ( 1 cement : 3 fine sand ) 124 white washing with lime to give an even shade : 125 new work ( three or more coats ) 126 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 127 new work ( two or more coats ) over and including water thinnable priming coat with cement primer 128 finishing walls with premium acrylic smooth exterior paint withsilicone additives of required shade: 129 new work ( two or more coats applied @ 1.43 ltr / 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm ) 130 applying priming coat: 131 with ready mixed pink or grey primer of approved brand and manufacture on wood work ( hard and soft wood ) 132 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron / steel works 133 painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 134 two or more coats on new work 135 painting with black anti corrosive bitumastic paint of approved brand and manufacture to give an even shade : 136 two or more coats on new work 137 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 138 water proofing 139 providing and laying in situ seven course water proofing treatment with app ( atactic poly propylene ) modified polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 kg / sqm, which shall consist of blown type bitumen of grade 85 / 25 conforming to is : 702, 3rd and 5th layers of roofing membrane app modified polymeric membrane 1.5 mm thick of 2.25 kg / sqm weight consisting of five layers prefabricated with centre core as 20 micron hmhdpe film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron hmhdpe film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 ( 1cement : 3 fine sand ) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 ( 1 cement : 3 fine sand ) and finished neat ( item of laying brick tiles shall be paid for separately ) . 140 providing and laying brick tiles over mumty roofs, grouted with cement mortar 1:3 ( 1 cement : 3 fine sand ) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 ( 1 cement : 3 fine sand ) and finished neat: 12.19.1 with common burnt clay f.p.s. ( non modular ) brick tilesof class designation 10 141 earth work 142 earth work in excavation by mechanical means ( hydraulic excavator ) / manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 sqm on plan ) , including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 143 all kinds of soil. 144 excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 145 all kinds of soil 146 pipes, cables etc, not exceeding 80 mm dia. 147 pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 148 filling available excavated earth ( excluding rock ) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 149 roofing 150 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, ( i ) single socketed pipes. 151 110 mm diameter 152 providing and fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 153 coupler 154 110 mm 155 bend 87.5° 156 110 mm bend 157 shoe ( plain ) 158 110 mm shoe 159 providing and fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with m.s. screws of required length, including cutting brick work and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand ) and making good the wall etc. complete. 160 110 mm 161 providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 162 sanitary installations 163 providing and fixing water closet squatting pan ( indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 164 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 165 providing and fixing wash basin with c.i. brackets, 15 mm c.p. brass pillar taps, 32 mm c.p. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 166 white vitreous china flat back wash basin size 550x 400 mm with single 15 mm c.p. brass pillar tap 167 providing and fixing stainless steel a isi 304 ( 18 / 8 ) kitchen sink as per is: 13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 168 kitchen sink with drain board 169 510x1040 mm bowl depth 250 mm 170 extra for using coloured pedestal type w.c pan ( european type ) with low level cistern of same colour instead of white vitreous china w.c pan and cistern. 171 providing and fixing 600x450 mm beveled edge mirror of superior glass ( of approved quality ) complete with 6 mm thick hard board ground fixed to wooden cleats with c.p. brass screws and washers complete. 172 providing and fixing toilet paper holder : 173 vitreous china 174 providing and fixing soil, waste and vent pipes : 175 100 mm dia. 176 centrifugally cast ( spun ) iron socket & spigot ( s&s ) pipe as per is: 3989 177 75mm diameter 178 centrifugally cast ( spun ) iron socketed pipe as per is: 3989 179 providing and fixing m.s. holder bat clamps of approved design to sand cast iron / cast iron ( spun ) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) , including cost of cutting holes and making good the walls etc. : 180 for 100 mm dia. pipe 181 for 75 mm dia. pipe 182 providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 183 100 mm 184 sand cast iron s&s as per is 3989 185 75 mm 186 sand cast iron s&s as per is 3989 187 providing and fixing plain bend of required degree. 188 100 mm 189 sand cast iron s&s as per is : 3989 190 75 mm 191 sand cast iron s&s as per is 3989 192 providing and fixing heel rest sanitary bend 193 100 mmdia 194 sand cast iron s&s as per is 3989 195 75 mm dia 196 sand cast iron s&s as per is 3989 197 providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 198 100x100x100mm 199 sand cast iron s&s as per is 3989 200 75x75x75mm 201 sand cast iron s&s as per is 3989 202 providing and fixing single equal plain junction of required degree 203 100x100x100mm 204 sand cast iron s&s as per is 3989 205 75x75x75mm 206 sand cast iron s&s as per is 3989 207 providing and fixing door piece, insertion rubber washer 3mm thick, bolts & nuts complete : 208 100 mm 209 sand cast iron s&s as per is 3989 210 75 mm 211 sand cast iron s&s as per is 3989 212 providing and fixing terminal guard : 213 100 mm 214 sand cast iron s&s as per is 3989 215 75 mm 216 sand cast iron s&s as per is 3989 217 providing and fixing collar : 218 100 mm 219 sand cast iron s&s as per is 3989 220 75 mm 221 sand cast iron s&s as per is 3989 222 providing lead caulked joints to sand cast iron / centrifugally cast ( spun ) iron pipes and fittings of diameter : 223 100 mm 224 75 mm 225 providing and fixing m.s. stays and clamps for sand cast iron / centrifugally cast ( spun ) iron pipes of diameter : 226 100 mm 227 75 mm 228 providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 229 100 mm inlet and 100 mm outlet 230 sand cast iron s&s as per is: 1729 231 cutting chases in brick masonry walls for following diameter sand cast iron / centrifugally cast ( spun ) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size ) , including necessary plaster and pointing in cement mortar 1:4 ( 1 cement : 4 coarse sand ) : 232 100 mm dia 233 painting sand cast iron / centrifugally cast ( spun ) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer ( of approved quality ) for new work : 234 100 mm diameter pipe 235 75 mm diameter pipe 236 providing and fixing ptmt waste coupling for wash basin and sink, of approved quality and colour. 237 waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms 238 providing and fixing ptmt bottle trap for wash basin and sink. 239 bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms 240 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 241 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour. 242 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 243 providing and fixing g.i. pipes complete with g.i. fittings including trenching & refilling. 244 external work 245 32mmdia nominal bore 246 40mmdia nominal bore 247 50mmdia nominal bore 248 water supply 249 providing and fixing chlorinated polyvinyl chloride ( cpvc ) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 250 internal work exposed on wall 251 25 mm nominal outer dia pipes metre 252 32 mm nominal outer dia pipes metre 253 providing and fixing chlorinated polyvinyl chloride ( cpvc ) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i / c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 254 concealed work, including cutting chases and making good the walls etc. 255 15 mm nominal outer dia pipes 256 20 mm nominal outer dia pipes 257 making connection of g.i. distribution branch with g.i. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 258 25 to 40 mm nominal bore 259 providing and fixing brass stop cock of approved quality : 260 15 mm nominal bore 261 20 mm nominal bore 262 providing and fixing gun metal gate valve with c.i. wheel of approved quality ( screwed end ) : 263 25mm nominal bore 264 32mm nominal bore 265 40mm nominal bore 266 providing and fixing ball valve ( brass ) of approved quality, high or low pressure, with plastic floats complete : 267 25 mm nominal bore 268 providing and fixing brass ferrule with c.i. mouth cover including boring and tapping the main : 269 25 mm nominal bore 270 providing and fixing uplasticised pvc connection pipe with brass unions : 271 45 cm length 272 15 mm nominal bore 273 providing and fixing c.p. brass shower rose with 15 or 20 mm inlet : 274 100 mm diameter 275 providing and placing on terrace ( at all floor levels ) polyethylene water storage tank, is : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 276 rectangular tank 277 providing and fixing c.p. brass bib cock of approved quality conforming to is:8931 : 278 15 mm nominal bore 279 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 280 15 mm nominal bore 281 providing and fixing c.p. brass stop cock ( concealed ) of standard design and of approved make conforming to is:8931. 282 15 mm nominal bore. 283 providing and fixing c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 284 15 mm nominal bore 285 providing and fixing ptmt grating of approved quality and colour. 286 circular type. 287 100 mm nominal dia. 288 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) , including finishing complete so as to make it leak proof. 289 sewarage & drainage 290 providing, laying and jointing glazed stoneware pipes class sp 1 with stiff mixture of cement mortar in the proportion of 1:1 ( 1 cement : 1 fine sand ) including testing of joints etc. complete : 291 100 mm diameter 292 150 mm diameter 293 providing and laying cement concrete 1:5:10 ( 1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size ) all round s.w. pipes including bed concrete as per standard design : 294 100 mm diameter s.w. pipe 295 150 mm diameter s.w. pipe 296 providing and fixing square mouth s.w. gully trap class sp 1 complete with c.i. grating brick masonry chamber with water tight c.i. cover with frame of 300 x300 mm size ( inside ) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70kg as per standard design: 297 150 x 100 mm size p type 298 with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 299 constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with r.c.c. top slab with 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) , foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size ) , inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand ) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design : 300 inside size 90x80 cm and 45 cm deep including c.i. cover with frame ( light duty ) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg ( weight of cover 23 kg and weight of frame 15 kg ) : 301 with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 302 extra for depth for manholes : 303 size 90x80 cm 304 with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 305 providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per is : 10910, on 12 mm dia steel bar conforming to is: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) complete as per design. 306 making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) cement plastered on both sides with cement mortar 1:3 ( 1 cement : 3 coarse sand ) , finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 307 for pipes 100 to 250 mm diameter 308 providing, laying and jointing non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete : 309 150 mm dia rcc pipe 310 non shedule items 311 providing and fixing floor drain points of 75 x 50mmreducer bend with 100 mm dia cp grating with frame, embedded in floor including making joints with waste pipe etc. complete in all respects as per drawing and as directed by theengineer in charge. 312 providing & fixing sink mixer with swinging casted spout ( wall mounted jaquar model con 309 kn ) / approved equal with 450mm long copper pipes & brass nuts. 313 providing and fixing concealed single leverbath & overhead shower mixer of hindware make and model no. ( f360019cp ) respectively or equivalent approved make as approved byengineer in charge. 314 supplying, fixing, testing and commissioning of storage type water heater ( geyser ) etc. with stainless steel body , copper container , automatic thermostatic control electric element, pressure release valve, m.s. nuts and bolts etc. conforming to is: 2082 315 25 litre capacity 316 ( electrical works ) 317 subhead i wiring 318 wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. 319 group c 320 wiring for light / power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 321 supplying and fixing following size / modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 322 4 module ( 125 mmx75 mm ) 323 supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 324 15 / 16 a switch 325 3 pin 5 / 6 a socket outlet 326 telephone socket outlet 327 tv antenna socket outlet 328 wiring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed steel conduit as required. 329 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire 330 2 x 10 sq. mm + 1 x 6 sq. mm earth wire 331 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface / recessed steel / pvc conduit as required. 332 supplying and fixing of following sizes of steel conduit along with accessories in surface / recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 333 25 mm 334 supplying and fixing following size / modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 335 1 or 2 module ( 75 mmx75 mm ) 336 supplying and drawing following pair 0.5 mm dia frls pvc insulated annealed copper conductor, unarmored telephone cable in the existing surface / recessed steel / pvc conduit as required. 337 2 pair 338 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. 339 20 mm 340 25 mm 341 providing and fixing in position 2mm thick m.s. telephone junction box of size suitable for fixing of following krone tag block with key lock arrangement. also provide clamps for fixing tag blocks. 342 10 pair telephone tag blockwith box 343 supplying, laying of 10 pair unarmoured pvc insulated copper conductor ( atc ) telephone cable in ground / existing pipes / on wall and making connection with telephone main junction box ( mdf ) including supports and all accessories as required 344 10 pair cable unarmoured 345 subhead ii supply & installation of fittings 346 supplying of following box type fl. fitting made out of crca sheet finished in antirust treated non yellowing super white stove enamelled paint duly wired with copper wound heavy duty choke starter holder, starter but without lamp complete etc. as reqd. 347 mounting rail for tled lamps 1600 lumens ( tmc 501 p 1xt led with essential led 18w tube ) 348 supplying of wall bracket light fittings suitable for 11 / 13 w cfl lamp. the fitting shall be made up of m.s. powder coated provided with integral ballast, frosted glass and 1 no. 11 / 13 wlamp duly wired upto the connector block complete as required. ( decon cat. no.05aam ) 349 supplying of ceiling light fittings suitable for 1 x 15 / 20 w led lamp. the fitting shall be made up of m.s. powder coated provided with electronic ballast, 1 no. 15 / 20 w led lamp duly wired upto the connector block etc. complete as required. 350 cirrus mini pro 15 / 20 watt & 1100 / 1600 lumens ( philips sm200c led11s 6500 psu od wh ) 351 supplying of bulk head fittings suitable for 10 w led lamp complete with ballast & accessories such as glass, wire guard, 60 w cfl lamp etc. complete as required. 352 endural led bulkhead, 10 w, 600 lumen such as ( philips wt202w led6s cw psu s2 pc ) 353 supplying of exhaustfan, all complete with mounting ring frame i / c bracket, but without regulator with shutters in the following sizes. ( g.e. alsthom, khaitan & havells company ) 354 300 mm 4 pole 355 supplying of 1400 mm sweep a.c. electric ceiling fans, capacitor type with double ball bearing complete with 300 mm down rod, canopies, shackles, blades, but without regulator suitable for operation on 230 / 240 volts, 50 hz, single phase, a.c. supply. ( crompton, khaitan & havells company ) 356 supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 357 installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 358 installation, testing and commissioning of pre wired, light fixture / compact fluorescent fitting of all types, complete with all accessories and tube / lamp etc. directly on ceiling / wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 359 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 360 upto 450 mm sweep 361 extra for fixing the louvers / shutters complete with frame for a exhaust fan of all sizes. 362 installation, testing and commissioning of wall bracket / ceiling fittings of all sizes and shapes containing upto two gls / cfl / led lamps per fitting, complete with all accessories including connections etc. as required. 363 supplying and fixing call bell / buzzer suitable for single phase, 230 v, complete as required. 364 subhead iii distribution board 365 supplying, installing, testing and commissioning of compartmentalised cubical type meter board for installation of single phase meter. the cubical board shall be made of 2mm thick c.r.c.a sheet, duly phosphatised powder coated complete with connection bus bar and following accessories mounted in it. 366 meter board 367 incoming : 368 40a tp mccb having breaking capacity 25 ka 1 no. 369 outgoing : 370 space for single phase energy meter 4 nos. 371 25 amp dp mcb 4 nos. 372 supplying, installing, testing & commissioning of single phase electronic energy meter, tested as per electricity boards requirement. 373 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 374 12 way, spn 375 supplying and fixing following rating, double pole, 240 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 376 40 amps 377 supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. asrequired. 378 25 amps 379 supplying of xlpe insulated, pvc sheathed 1.1 kv grade aluminium conductor heavy duty armoured cable as per is : 7098 of size : 380 4 x 16 sq.mm. 381 providing, laying and fixing following dia rcc pipe np2 class ( light duty ) in ground complete with rcc collars, jointing with cement mortar 1:2 ( 1 cement : 2 fine sand ) including trenching ( 75 cm deep ) and refilling etc. as required for crossing road / walls 382 100 mm dia 383 supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 384 single pole 385 subhead iv earthing 386 earthing with g.i. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. 387 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re filling as required. 388 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 389 staff quarters type iii 390 earth work 391 earth work in excavation by mechanical means ( hydraulic excavator ) / manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 sqm on plan ) , including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 392 all kinds of soil 393 filling available excavated earth ( excluding rock ) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 394 supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 395 supplying chemical emulsion in sealed containers including delivery as specified. 396 chlorpyriphos / lindane emulsifiable concentrate of 20% 397 diluting and injecting chemical emulsion for post constructional anti termite treatment ( excluding the cost of chemical emulsion ) : 398 treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 ( 1 cement : 2 coarse sand ) to match the existing floor: 399 with chlorpyriphos / lindane e.c. 20% with 1% concentration 400 excavating, supplying and filling of local earth ( including royalty ) by mechanical transport upto a lead of 5km also includingramming and watering of the earth in layers not exceeding 20cm in trenches, plinth, sides of foundation etc. complete. 401 concrete work 402 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 403 1:5:10 ( 1 cement : 5 coarse sand ( zone iii ) : 10 graded stone aggregate 40 mm nominal size ) 404 providing and laying cement concrete in retaining walls, return walls, walls ( any thickness ) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : 405 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) . 406 making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 407 providing and laying damp proof course 40mm thick with cement concrete 1:2:4 ( 1 cement : 2 coarse sand ( zone iii ) : 4 graded stone aggregate 12.5mm nominal size ) 408 providing & applying a coat of residual petroleum bitumen of grade of vg 10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 409 reinforcedcementconcrete 410 centering and shuttering including strutting, propping etc. and removal of form for all heights: 411 foundations, footings, bases of columns, etc. for mass concrete 412 walls ( any thickness ) including attached pilasters, butteresses, plinth and string courses etc 413 columns, pillars, piers, abutments, posts and struts 414 small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like 415 edges of slabs and breaks in floors and walls 416 under 20 cms wide 417 suspended floors, roofs, landings, balconies and access platform. 418 lintels, beams, plinth beams, girders, bressumers and cantilevers. 419 providing precast cement concrete jali 1:2:4 ( 1 cement : 2 coarse sand ( zone iii ) : 4 graded stone aggregate 6mm nominal size ) , reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing with cement mortar 1:3 ( 1 cement: 3 fine sand ) etc. complete, excluding plastering of the jambs, sills and soffits. 420 50 mm thick 421 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 422 thermo mechanically treated bars of grade fe 500d or more. 423 add for plaster drip course / groove in plastered surface or moulding to r.c.c. projections. 424 providing and laying in position machine batched and machine mixed design mix m 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per is: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of engineer in charge.“ ( note : cement content considered in this item is @ 330 kg / cum.“excess / less cement used as per design mix is payable / recoverable separately ) . 425 all works upto plinth level 426 all works above plinth level upto floor v level 427 add for using extra cement in the items of design mix over and above the specified cement content therein. 428 brick work 429 brick work with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 in foundation and plinth in: 430 cement mortar 1:6 ( 1 cement : 6 coarse sand ) 431 providing and laying autoclaved aerated cement blocks masonry with 150mm / 230mm / 300 mm thick aac blocks in super structure above plinth level up to floor v level with rcc band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of engineer in charge. ( the payment of rcc band and reinforcement shall be made for seperately ) . 432 half brick masonry with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 in superstructure above plinth level up to floor v level. 433 cement mortar 1:4 ( 1 cement :4 coarse sand ) 434 extra for providing and placing in position 2 nos 6mm dia. m.s. bars at every third course of half brick masonry. 435 brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 including grouting with cement mortar 1:4 ( 1 cement : 4 fine sand ) . 436 marble work 437 providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand ) , joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 438 granite of any colour and shade 439 area of slab over 0.50 sqm 440 providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer in charge. 441 granite work 442 extra for fixing marble / granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. 443 extra for providing opening of required size & shape for wash basin / kitchen sink in kitchen platform, vanity counter and similar location in marble / granite / stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 444 wood work & pvc work 445 providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately ) . 446 second class teak wood 447 extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. ( area of opening for glass panes excluding portion inside rebate shall be measured ) . 448 providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 449 25 mm thick ( for cupboard ) including isi marked nickel plated bright finished m.s. piano hinges is : 3818 marked with necessary screws 450 providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) non decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 451 35 mm thick including isi marked stainless steel butt hinges with necessary screws 452 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters ( over all area of door shutter to be measured ) . 453 providing and fixing wire gauge shutters using galvanized m.s. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 454 35 mm thick shutters 455 kiln seasoned and chemically treated hollock wood 456 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coat with approved steel primer all complete. 457 fixed to steel windows by welding 458 providing and fixing fly proof galvanized m.s. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. 459 with 12 mm mild steel u beading 460 providing and fixing oxidised m.s. casement stays ( straight peg type ) with necessary screws etc. complete. 461 250 mm weighing not less than 150 gms 462 providing and fixing aluminium sliding door bolts, isi marked anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) , transparent or dyed to required colour or shade, with nuts and screws etc. complete : 463 250x16 mm 464 providing and fixing aluminium tower bolts, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 465 200x10 mm 466 providing and fixing aluminium handles, isi marked, anodised ( anodiccoating not less than grade ac 10 as per is : 1868 ) transparent or dyedto required colour or shade, with necessary screws etc. complete : 467 125 mm 468 providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. 469 twin rubber stopper 470 providing & fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to is : 2046 type s, including cost of adhesive of approved quality. 471 1.5 mm thick 472 providing and fixing pre laminated flat pressed 3 layer ( medium density ) particle board or graded wood particle board is : 3087 marked, with oneside decorative and other side balancing lamination grade i, type iiexterior grade is : 12823 marked, in shelves with screws and fittingswherever required, edges to be painted with polyurethane primer ( fittingsto be paid separately ) . 473 18 mm thick 474 providing and fixing factory made upvc white colour sliding glazed window upto 1.50 m in height dimension comprising of upvc multi chambered frame with in built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length ( shape & size according to upvc profile ) , appropriate dimension of upvc extruded glazing beads and upvc extruded interlocks, epdm gasket, wool pile, zinc alloy ( white powder coated ) touch locks with hook, zinc alloy body with single nylon rollers ( weight bearing capacity to be 40 kg ) , g.i fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of engineer in charge. ( single / double glass panes, wire mesh and silicon sealent shall be paid separately ) . variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 475 three track three panels sliding window with fly proof s.s wire mesh ( two nos. glazed & one no. wire mesh panels ) made of ( big series ) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. ( area of window above 1.75 sqm ) . 476 providing and fixing isi marked oxidised m.s. single acting spring hingeswith necessary screws etc. complete : 477 150 mm 478 providing and fixing oxidised m.s. hasp and staple ( safety type ) conforming to is : 363 with necessary screws etc. complete : 479 90 mm 480 providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 481 75 mm 482 providing and fixing wooden moulded corner beading of triangular shape to the junction of panelling etc. with iron screws, plugs and priming coat on unexposed surface etc. complete 2nd class teak wood. 483 50x50 mm ( base and height ) 484 float glass panes 485 4 mm thick glass pane ( weight not less than 10kg / sqm ) . 486 steel work 487 providing and fixing 1mm thick m.s. sheet door with frame of 40x40x6 mm angle iron and 3 mm m.s. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 488 using m.s. angles 40x40x6 mm for diagonal braces 489 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side / top / centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, ( sectional weight of only steel members shall be measured for payment ) . 490 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) 491 providing and fixing t iron frames for doors, windows and ventilators of mild steel tee sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 492 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) 493 providing and fixing circular / hexagonal cast iron or m.s. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick m.s. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron / m.s. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. clamp shall be made of 12 mm dia m.s. bar bent to shape as per standard drawing. 494 providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. 495 m.s. tube 496 providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 497 4.0 mm thick glass panes 498 flooring 499 providing and fixing glass strips in joints of terrazo / cement concrete floors. 500 40 mm wide and 4 mm thick 501 kota stone slab flooring over 20 mm ( average ) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 ( 1 cement : 4 coarse sand ) : 502 25 mm thick. 503 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm ( average ) thick cement mortar 1:3 ( 1 cement: 3 coarse sand ) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 504 extra for pre finished nosing in treads of steps of kota stone / sand stone slab. 505 extra for kota stone / sand stone in treads of steps and risers using single length up to 1.05 metre. 506 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 507 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3kg / sqm including pointing the joints with white cement and matching pigment etc., complete. 508 providing and laying vitrified floor tiles in different sizes ( thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3kg / sqm including grouting the joints with white cement and matching pigments etc., complete. 509 size of tile 600x600 mm 510 providing and laying vitrified tiles in different sizes ( thickness to be specified by manufacturer ) , with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 ( 1cement: 3 coarse sand ) , jointing with grey cement slurry @ 3.3kg / sqm including grouting the joint with white cement & matching pigments etc. complete. 511 size of tile 400x400 mm 512 roofing 513 providing and laying brick tiles over mumty roofs, grouted with cement mortar 1:3 ( 1 cement : 3 fine sand ) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 ( 1 cement : 3 fine sand ) and finished neat. 514 with common burnt clay f.p.s. ( non modular ) brick tilesof class designation 10 515 making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size ) over p.v.c. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 ( 1 cement : 3 coarse sand ) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 516 finishing 517 12 mm cement plaster of mix 518 1:6 ( 1 cement: 6 coarse sand ) 519 15 mm cement plaster on rough side of single or half brick wall of mix: 520 1:6 ( 1 cement: 6 coarse sand ) 521 cement plaster 1:3 ( 1 cement: 3 coarse sand ) finished with a floatingcoat of neat cement. 522 20 mm cement plaster 523 6mm cement plaster of mix 524 1:3 ( 1 cement : 3 fine sand ) 525 white washing with lime to give an even shade : 526 new work ( three or more coats ) 527 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 528 new work ( two or more coats ) over and including water thinnable priming coat with cement primer 529 finishing walls with premium acrylic smooth exterior paint withsilicone additives of required shade: 530 new work ( two or more coats applied @ 1.43 ltr / 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm ) 531 applying priming coat: 532 with ready mixed pink or grey primer of approved brand and manufacture on wood work ( hard and soft wood ) 533 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron / steel works 534 painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 535 two or more coats on new work 536 painting with black anti corrosive bitumastic paint of approved brand and manufacture to give an even shade : 537 two or more coats on new work 538 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 539 water proofing 540 providing and laying in situ seven course water proofing treatment with app ( atactic poly propylene ) modified polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 kg / sqm, which shall consist of blown type bitumen of grade 85 / 25 conforming to is : 702, 3rd and 5th layers of roofing membrane app modified polymeric membrane 1.5 mm thick of 2.25 kg / sqm weight consisting of five layers prefabricated with centre core as 20 micron hmhdpe film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron hmhdpe film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 ( 1cement : 3 fine sand ) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 ( 1 cement : 3 fine sand ) and finished neat ( item of laying brick tiles shall be paid for separately ) . 541 applying a slurry coat of neat cement using 2.75 kg / sqm of cement admixed with water proofing compound conforming to is. 2645 and approved by engineer in charge over the rcc slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. 542 laying brick bats with mortar using broken bricks / brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 ( 1 cement : 5 coarse sand ) admixed with water proofing compound conforming to is : 2645 and approved by engineerin charge over 20 mm thick layer of cement mortar of mix 1:5 ( 1 cement :5 coarse sand ) admixed with water proofing compound conforming to is : 2645 and approved by engineerin charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. 543 after two days of proper curing applying a second coat of cement slurry using 2.75 kg / sqm of cement admixed with water proofing compound conforming to is : 2645 and approved by engineer in charge. 544 finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 ( 1 cement :4 coarse sand ) admixed with water proofing compound conforming to is : 2645 and approved by engineer in charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. 545 the whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“all above operations to be done in order and as directed and specified by the engineer in charge : 546 providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of w.c., kitchen and the like consisting of: 547 ist course of applying cement slurry @ 4.4 kg / sqm mixed with water proofing compound conforming to is 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. 548 iind course of 20 mm cement plaster 1:3 ( 1 cement : 3 coarse sand ) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. 549 iiird course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. 550 ivth course of 400 micron thick pvc sheet. ( overlaps at joints of pvc sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg / sqm ) . 551 non shedule items 552 providing and laying cinder filling in sunken floors and other locationswith approved quality cinder including watering and light ramming etc.required for proper compaction / completion of the work complete in all respects as per drawings and as directed by the engineer in charge. 553 providing and fixing aluminium handles, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 554 150 mm 555 providing and fixing aluminium door buffer of approved make, design and colour with necessary screws etc all complete as directed and specified by the engineer in charge : 556 providing and laying 1st quality ceramic glazed anti skid floortiles of size 300x300 mm ( thickness to be specified by the manufacturer ) conforming to is:15622 in all colours, shades, sizes as approved over 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand ) including pointing the joints with white cement and matching pigment etc complete in all respects as per specifications / drawings and to the entire satisfaction to the architect. 557 staff quarter iii ( g+1 ) 558 earth work 559 earth work in excavation by mechanical means ( hydraulic excavator ) / manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 sqm on plan ) , including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 560 all kinds of soil. 561 excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 562 all kinds of soil 563 pipes, cables etc, not exceeding 80 mm dia. 564 pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 565 filling available excavated earth ( excluding rock ) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 566 roofing 567 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, ( i ) single socketed pipes. 568 110 mm diameter 569 providing and fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 570 coupler 571 110 mm 572 bend 87.5° 573 110 mm bend 574 shoe ( plain ) 575 110 mm shoe 576 providing and fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with m.s. screws of required length, including cutting brick work and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand ) and making good the wall etc. complete. 577 110 mm 578 providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 579 sanitary installations 580 providing and fixing water closet squatting pan ( indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 581 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 582 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. 583 w.c. pan with isi marked white solid plastic seat and lid 584 providing and fixing wash basin with c.i. brackets, 15 mm c.p. brass pillar taps, 32 mm c.p. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 585 white vitreous china flat back wash basin size 550x 400 mm with single 15 mm c.p. brass pillar tap 586 providing and fixing stainless steel a isi 304 ( 18 / 8 ) kitchen sink as per is: 13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 587 kitchen sink with drain board 588 510x1040 mm bowl depth 250 mm 589 extra for using coloured pedestal type w.c pan ( european type ) with low level cistern of same colour instead of white vitreous china w.c pan and cistern. 590 providing and fixing 600x450 mm beveled edge mirror of superior glass ( of approved quality ) complete with 6 mm thick hard board ground fixed to wooden cleats with c.p. brass screws and washers complete. 591 providing and fixing toilet paper holder : 592 vitreous china 593 providing and fixing soil, waste and vent pipes : 594 100 mm dia. 595 centrifugally cast ( spun ) iron socket & spigot ( s&s ) pipe as per is: 3989 596 75mm diameter 597 centrifugally cast ( spun ) iron socketed pipe as per is: 3989 598 providing and fixing m.s. holder bat clamps of approved design to sand cast iron / cast iron ( spun ) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) , including cost of cutting holes and making good the walls etc. : 599 for 100 mm dia. pipe 600 for 75 mm dia. pipe 601 providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 602 100 mm 603 sand cast iron s&s as per is 3989 604 75 mm 605 sand cast iron s&s as per is 3989 606 providing and fixing plain bend of required degree. 607 100 mm 608 sand cast iron s&s as per is : 3989 609 75 mm 610 sand cast iron s&s as per is 3989 611 providing and fixing heel rest sanitary bend 612 100 mmdia 613 sand cast iron s&s as per is 3989 614 75 mm dia 615 sand cast iron s&s as per is 3989 616 providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 617 100x100x100mm 618 sand cast iron s&s as per is 3989 619 75x75x75mm 620 sand cast iron s&s as per is 3989 621 providing and fixing single equal plain junction of required degree 622 100x100x100mm 623 sand cast iron s&s as per is 3989 624 75x75x75mm 625 sand cast iron s&s as per is 3989 626 providing and fixing door piece, insertion rubber washer 3mm thick, bolts & nuts complete : 627 100 mm 628 sand cast iron s&s as per is 3989 629 75 mm 630 sand cast iron s&s as per is 3989 631 providing and fixing terminal guard : 632 100 mm 633 sand cast iron s&s as per is 3989 634 75 mm 635 sand cast iron s&s as per is 3989 636 providing and fixing collar : 637 100 mm 638 sand cast iron s&s as per is 3989 639 75 mm 640 sand cast iron s&s as per is 3989 641 providing lead caulked joints to sand cast iron / centrifugally cast ( spun ) iron pipes and fittings of diameter : 642 100 mm 643 75 mm 644 providing and fixing m.s. stays and clamps for sand cast iron / centrifugally cast ( spun ) iron pipes of diameter : 645 100 mm 646 75 mm 647 providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 648 100 mm inlet and 100 mm outlet 649 sand cast iron s&s as per is: 1729 650 cutting chases in brick masonry walls for following diameter sand cast iron / centrifugally cast ( spun ) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size ) , including necessary plaster and pointing in cement mortar 1:4 ( 1 cement : 4 coarse sand ) : 651 100 mm dia 652 painting sand cast iron / centrifugally cast ( spun ) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer ( of approved quality ) for new work : 653 100 mm diameter pipe 654 75 mm diameter pipe 655 providing and fixing ptmt waste coupling for wash basin and sink, of approved quality and colour. 656 waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms 657 providing and fixing ptmt bottle trap for wash basin and sink. 658 bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms 659 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 660 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour. 661 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 662 providing and fixing g.i. pipes complete with g.i. fittings including trenching & refilling. 663 external work 664 32mmdia nominal bore 665 40mmdia nominal bore 666 50mmdia nominal bore 667 water supply 668 providing and fixing chlorinated polyvinyl chloride ( cpvc ) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 669 internal work exposed on wall 670 25 mm nominal outer dia pipes metre 671 32 mm nominal outer dia pipes metre 672 providing and fixing chlorinated polyvinyl chloride ( cpvc ) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i / c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 673 concealed work, including cutting chases and making good the walls etc. 674 15 mm nominal outer dia pipes 675 20 mm nominal outer dia pipes 676 making connection of g.i. distribution branch with g.i. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 677 25 to 40 mm nominal bore 678 providing and fixing brass stop cock of approved quality : 679 15 mm nominal bore 680 20 mm nominal bore 681 providing and fixing gun metal gate valve with c.i. wheel of approved quality ( screwed end ) : 682 25mm nominal bore 683 32mm nominal bore 684 40mm nominal bore 685 providing and fixing ball valve ( brass ) of approved quality, high or low pressure, with plastic floats complete : 686 25 mm nominal bore 687 providing and fixing brass ferrule with c.i. mouth cover including boring and tapping the main : 688 25 mm nominal bore 689 providing and fixing uplasticised pvc connection pipe with brass unions : 690 45 cm length 691 15 mm nominal bore 692 providing and fixing c.p. brass shower rose with 15 or 20 mm inlet : 693 100 mm diameter 694 providing and placing on terrace ( at all floor levels ) polyethylene water storage tank, is : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 695 rectangular tank 696 providing and fixing c.p. brass bib cock of approved quality conforming to is:8931 : 697 15 mm nominal bore 698 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 699 15 mm nominal bore 700 providing and fixing c.p. brass stop cock ( concealed ) of standard design and of approved make conforming to is:8931. 701 15 mm nominal bore. 702 providing and fixing c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 703 15 mm nominal bore 704 providing and fixing ptmt grating of approved quality and colour. 705 circular type. 706 100 mm nominal dia. 707 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) , including finishing complete so as to make it leak proof. 708 sewarage & drainage 709 providing, laying and jointing glazed stoneware pipes class sp 1 with stiff mixture of cement mortar in the proportion of 1:1 ( 1 cement : 1 fine sand ) including testing of joints etc. complete : 710 100 mm diameter 711 150 mm diameter 712 providing and laying cement concrete 1:5:10 ( 1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size ) all round s.w. pipes including bed concrete as per standard design : 713 100 mm diameter s.w. pipe 714 150 mm diameter s.w. pipe 715 providing and fixing square mouth s.w. gully trap class sp 1 complete with c.i. grating brick masonry chamber with water tight c.i. cover with frame of 300 x300 mm size ( inside ) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70kg as per standard design: 716 150 x 100 mm size p type 717 with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 718 constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with r.c.c. top slab with 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) , foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size ) , inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand ) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design : 719 inside size 90x80 cm and 45 cm deep including c.i. cover with frame ( light duty ) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg ( weight of cover 23 kg and weight of frame 15 kg ) : 720 with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 721 extra for depth for manholes : 722 size 90x80 cm 723 with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 724 providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per is : 10910, on 12 mm dia steel bar conforming to is: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) complete as per design. 725 making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) cement plastered on both sides with cement mortar 1:3 ( 1 cement : 3 coarse sand ) , finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 726 for pipes 100 to 250 mm diameter 727 providing, laying and jointing non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete : 728 150 mm dia rcc pipe 729 250 mm dia rcc pipe 730 non shedule items 731 providing and fixing floor drain points of 75 x 50mmreducer bend with 100 mm dia cp grating with frame, embedded in floor including making joints with waste pipe etc. complete in all respects as per drawing and as directed by theengineer in charge. 732 providing & fixing sink mixer with swinging casted spout ( wall mounted jaquar model con 309 kn ) / approved equal with 450mm long copper pipes & brass nuts. 733 providing and fixing concealed single leverbath & overhead shower mixer of hindware make and model no. ( f360019cp ) respectively or equivalent approved make as approved byengineer in charge. 734 supplying, fixing, testing and commissioning of storage type water heater ( geyser ) etc. with stainless steel body , copper container , automatic thermostatic control electric element, pressure release valve, m.s. nuts and bolts etc. conforming to is: 2082 735 25 litre capacity 736 sq type iii ( g+1 ) 737 subhead i wiring 738 wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. 739 group c 740 wiring for light / power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 741 supplying and fixing following size / modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 742 4 module ( 125 mmx75 mm ) 743 supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 744 15 / 16 a switch 745 3 pin 5 / 6 a socket outlet 746 telephone socket outlet 747 tv antenna socket outlet 748 wiring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed steel conduit as required. 749 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire 750 2 x 10 sq. mm + 1 x 6 sq. mm earth wire 751 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface / recessed steel / pvc conduit as required. 752 supplying and fixing of following sizes of steel conduit along with accessories in surface / recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 753 25 mm 754 supplying and fixing following size / modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 755 1 or 2 module ( 75 mmx75 mm ) 756 supplying and drawing following pair 0.5 mm dia frls pvc insulated annealed copper conductor, unarmored telephone cable in the existing surface / recessed steel / pvc conduit as required. 757 2 pair 758 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. 759 20 mm 760 25 mm 761 providing and fixing in position 2mm thick m.s. telephone junction box of size suitable for fixing of following krone tag block with key lock arrangement. also provide clamps for fixing tag blocks. 762 10 pair telephone tag blockwith box 763 supplying, laying of 10 pair unarmoured pvc insulated copper conductor ( atc ) telephone cable in ground / existing pipes / on wall and making connection with telephone main junction box ( mdf ) including supports and all accessories as required 764 10 pair cable unarmoured 765 subhead ii supply & installation of fittings 766 supplying of following box type fl. fitting made out of crca sheet finished in antirust treated non yellowing super white stove enamelled paint duly wired with copper wound heavy duty choke starter holder, starter but without lamp complete etc. as reqd. 767 mounting rail for tled lamps 1600 lumens ( tmc 501 p 1xt led with essential led 18w tube ) 768 supplying of wall bracket light fittings suitable for 11 / 13 w cfl lamp. the fitting shall be made up of m.s. powder coated provided with integral ballast, frosted glass and 1 no. 11 / 13 wlamp duly wired upto the connector block complete as required. ( decon cat. no.05aam ) 769 supplying of ceiling light fittings suitable for 1 x 15 / 20 w led lamp. the fitting shall be made up of m.s. powder coated provided with electronic ballast, 1 no. 15 / 20 w led lamp duly wired upto the connector block etc. complete as required. 770 cirrus mini pro 15 / 20 watt & 1100 / 1600 lumens ( philips sm200c led11s 6500 psu od wh ) 771 supplying of bulk head fittings suitable for 10 w led lamp complete with ballast & accessories such as glass, wire guard, 60 w cfl lamp etc. complete as required. 772 endural led bulkhead, 10 w, 600 lumen such as ( philips wt202w led6s cw psu s2 pc ) 773 supplying of exhaustfan, all complete with mounting ring frame i / c bracket, but without regulator with shutters in the following sizes. ( g.e. alsthom, khaitan & havells company ) 774 300 mm 4 pole 775 supplying of 1400 mm sweep a.c. electric ceiling fans, capacitor type with double ball bearing complete with 300 mm down rod, canopies, shackles, blades, but without regulator suitable for operation on 230 / 240 volts, 50 hz, single phase, a.c. supply. ( crompton, khaitan & havells company ) 776 supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 777 installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 778 installation, testing and commissioning of pre wired, light fixture / compact fluorescent fitting of all types, complete with all accessories and tube / lamp etc. directly on ceiling / wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 779 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 780 upto 450 mm sweep 781 extra for fixing the louvers / shutters complete with frame for a exhaust fan of all sizes. 782 installation, testing and commissioning of wall bracket / ceiling fittings of all sizes and shapes containing upto two gls / cfl / led lamps per fitting, complete with all accessories including connections etc. as required. 783 supplying and fixing call bell / buzzer suitable for single phase, 230 v, complete as required. 784 subhead iii distribution board 785 supplying, installing, testing and commissioning of compartmentalised cubical type meter board for installation of single phase meter. the cubical board shall be made of 2mm thick c.r.c.a sheet, duly phosphatised powder coated complete with connection bus bar and following accessories mounted in it. 786 meter board 787 incoming : 788 40a tp mccb having breaking capacity 25 ka 1 no. 789 outgoing : 790 space for single phase energy meter 4 nos. 791 25 amp dp mcb 4 nos. 792 supplying, installing, testing & commissioning of single phase electronic energy meter, tested as per electricity boards requirement. 793 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 794 12 way, spn 795 supplying and fixing following rating, double pole, 240 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 796 40 amps 797 supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. asrequired. 798 25 amps 799 supplying of xlpe insulated, pvc sheathed 1.1 kv grade aluminium conductor heavy duty armoured cable as per is : 7098 of size : 800 4 x 16 sq.mm. 801 providing, laying and fixing following dia rcc pipe np2 class ( light duty ) in ground complete with rcc collars, jointing with cement mortar 1:2 ( 1 cement : 2 fine sand ) including trenching ( 75 cm deep ) and refilling etc. as required for crossing road / walls 802 100 mm dia 803 supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 804 single pole 805 subhead iv earthing 806 earthing with g.i. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. 807 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re filling as required. 808 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 809 subhead v lightning conductor 810 providing and fixing of lightning conductor finial, made of 25mm dia 300 mm long, g.i. tube, having single prong at top, with85 mm dia 6 mm thick g.i. base plate including holes etc.complete as required. 811 jointing copper / g.i. tape ( with another copper / g i tape, base of the finial or any other metallic object ) by riveting / nut bolting / sweating and soldering etc as required. 812 fixing of copper / g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( for horizontal run ) 813 fixing of copper / g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( for vertical run ) 814 providing and fixing testing joint, made of 20 mm x 3 mm thickg.i. strip, 125 mm long, with 4 nos. of g.i. bolts, nuts, chucknuts and spring washers etc. complete as required. 815 laying copper / g.i. tape 32 mm x 6 mm from earth electrodedirectly in ground as required 816 staff quarters type ii 817 earth work 818 earth work in excavation by mechanical means ( hydraulic excavator ) / manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 sqm on plan ) , including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 819 all kinds of soil 820 filling available excavated earth ( excluding rock ) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 821 supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 822 supplying chemical emulsion in sealed containers including delivery as specified. 823 chlorpyriphos / lindane emulsifiable concentrate of 20% 824 diluting and injecting chemical emulsion for post constructional anti termite treatment ( excluding the cost of chemical emulsion ) : 825 treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 ( 1 cement : 2 coarse sand ) to match the existing floor: 826 with chlorpyriphos / lindane e.c. 20% with 1% concentration 827 excavating, supplying and filling of local earth ( including royalty ) by mechanical transport upto a lead of 5km also includingramming and watering of the earth in layers not exceeding 20cm in trenches, plinth, sides of foundation etc. complete. 828 concrete work 829 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 830 1:5:10 ( 1 cement : 5 coarse sand ( zone iii ) : 10 graded stone aggregate 40 mm nominal size ) 831 providing and laying cement concrete in retaining walls, return walls, walls ( any thickness ) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : 832 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) . 833 providing and laying damp proof course 40mm thick with cement concrete 1:2:4 ( 1 cement : 2 coarse sand ( zone iii ) : 4 graded stone aggregate 12.5mm nominal size ) 834 providing & applying a coat of residual petroleum bitumen of grade of vg 10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 835 making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 836 reinforcedcementconcrete 837 centering and shuttering including strutting, propping etc. and removal of form for all heights: 838 foundations, footings, bases of columns, etc. for mass concrete 839 walls ( any thickness ) including attached pilasters, butteresses, plinth and string courses etc 840 columns, pillars, piers, abutments, posts and struts 841 small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like 842 edges of slabs and breaks in floors and walls 843 under 20 cms wide 844 suspended floors, roofs, landings, balconies and access platform. 845 lintels, beams, plinth beams, girders, bressumers and cantilevers. 846 providing precast cement concrete jali 1:2:4 ( 1 cement : 2 coarse sand ( zone iii ) : 4 graded stone aggregate 6mm nominal size ) , reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing with cement mortar 1:3 ( 1 cement: 3 fine sand ) etc. complete, excluding plastering of the jambs, sills and soffits. 847 50 mm thick 848 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 849 thermo mechanically treated bars of grade fe 500d or more. 850 add for plaster drip course / groove in plastered surface or moulding to r.c.c. projections. 851 providing and laying in position machine batched and machine mixed design mix m 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per is: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of engineer in charge.“ ( note : cement content considered in this item is @ 330 kg / cum.“excess / less cement used as per design mix is payable / recoverable separately ) . 852 all works upto plinth level 853 all works above plinth level upto floor v level 854 add for using extra cement in the items of design mix over and above the specified cement content therein. 855 brick work 856 brick work with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 in foundation and plinth in: 857 cement mortar 1:6 ( 1 cement : 6 coarse sand ) 858 providing and laying autoclaved aerated cement blocks masonry with 150mm / 230mm / 300 mm thick aac blocks in super structure above plinth level up to floor v level with rcc band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of engineer in charge. ( the payment of rcc band and reinforcement shall be made for seperately ) . 859 half brick masonry with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 in superstructure above plinth level up to floor v level. 860 cement mortar 1:4 ( 1 cement :4 coarse sand ) 861 extra for providing and placing in position 2 nos 6mm dia. m.s. bars at every third course of half brick masonry. 862 brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 including grouting with cement mortar 1:4 ( 1 cement : 4 fine sand ) . 863 marble work 864 providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand ) , joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 865 granite of any colour and shade 866 area of slab over 0.50 sqm 867 providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer in charge. 868 granite work 869 extra for fixing marble / granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. 870 extra for providing opening of required size & shape for wash basin / kitchen sink in kitchen platform, vanity counter and similar location in marble / granite / stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 871 wood work & pvc work 872 providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately ) . 873 second class teak wood 874 extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. ( area of opening for glass panes excluding portion inside rebate shall be measured ) . 875 providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 876 25 mm thick ( for cupboard ) including isi marked nickel plated bright finished m.s. piano hinges is : 3818 marked with necessary screws 877 providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) non decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 878 35 mm thick including isi marked stainless steel butt hinges with necessary screws 879 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters ( over all area of door shutter to be measured ) . 880 providing and fixing wire gauge shutters using galvanized m.s. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 881 35 mm thick shutters 882 kiln seasoned and chemically treated hollock wood 883 providing and fixing m.s. grills of required pattern in frames of windows etc. with m.s. flats, square or round bars etc. including priming coat with approved steel primer all complete. 884 fixed to steel windows by welding 885 providing and fixing fly proof galvanized m.s. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. 886 with 12 mm mild steel u beading 887 providing and fixing oxidised m.s. casement stays ( straight peg type ) with necessary screws etc. complete. 888 250 mm weighing not less than 150 gms 889 providing and fixing aluminium sliding door bolts, isi marked anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) , transparent or dyed to required colour or shade, with nuts and screws etc. complete : 890 250x16 mm 891 providing and fixing aluminium tower bolts, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 892 200x10 mm 893 providing and fixing aluminium handles, isi marked, anodised ( anodiccoating not less than grade ac 10 as per is : 1868 ) transparent or dyedto required colour or shade, with necessary screws etc. complete : 894 125 mm 895 providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. 896 twin rubber stopper 897 providing & fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to is : 2046 type s, including cost of adhesive of approved quality. 898 1.5 mm thick 899 providing and fixing pre laminated flat pressed 3 layer ( medium density ) particle board or graded wood particle board is : 3087 marked, with oneside decorative and other side balancing lamination grade i, type iiexterior grade is : 12823 marked, in shelves with screws and fittingswherever required, edges to be painted with polyurethane primer ( fittingsto be paid separately ) . 900 18 mm thick 901 providing and fixing factory made upvc white colour sliding glazed window upto 1.50 m in height dimension comprising of upvc multi chambered frame with in built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length ( shape & size according to upvc profile ) , appropriate dimension of upvc extruded glazing beads and upvc extruded interlocks, epdm gasket, wool pile, zinc alloy ( white powder coated ) touch locks with hook, zinc alloy body with single nylon rollers ( weight bearing capacity to be 40 kg ) , g.i fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of engineer in charge. ( single / double glass panes, wire mesh and silicon sealent shall be paid separately ) . variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 902 three track three panels sliding window with fly proof s.s wire mesh ( two nos. glazed & one no. wire mesh panels ) made of ( big series ) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. ( area of window above 1.75 sqm ) . 903 providing and fixing isi marked oxidised m.s. single acting spring hingeswith necessary screws etc. complete : 904 150 mm 905 providing and fixing oxidised m.s. hasp and staple ( safety type ) conforming to is : 363 with necessary screws etc. complete : 906 90 mm 907 providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 908 75 mm 909 providing and fixing wooden moulded corner beading of triangular shape to the junction of panelling etc. with iron screws, plugs and priming coat on unexposed surface etc. complete 2nd class teak wood. 910 50x50 mm ( base and height ) 911 float glass panes 912 4 mm thick glass pane ( weight not less than 10kg / sqm ) . 913 steel work 914 providing and fixing 1mm thick m.s. sheet door with frame of 40x40x6 mm angle iron and 3 mm m.s. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 915 using m.s. angles 40x40x6 mm for diagonal braces 916 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side / top / centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, ( sectional weight of only steel members shall be measured for payment ) . 917 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) 918 providing and fixing t iron frames for doors, windows and ventilators of mild steel tee sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 919 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) 920 providing and fixing circular / hexagonal cast iron or m.s. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick m.s. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron / m.s. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. clamp shall be made of 12 mm dia m.s. bar bent to shape as per standard drawing. 921 providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. 922 m.s. tube 923 providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 924 4.0 mm thick glass panes 925 flooring 926 providing and fixing glass strips in joints of terrazo / cement concrete floors. 927 40 mm wide and 4 mm thick 928 kota stone slab flooring over 20 mm ( average ) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 ( 1 cement : 4 coarse sand ) : 929 25 mm thick. 930 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm ( average ) thick cement mortar 1:3 ( 1 cement: 3 coarse sand ) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 931 extra for pre finished nosing in treads of steps of kota stone / sand stone slab. 932 extra for kota stone / sand stone in treads of steps and risers using single length up to 1.05 metre. 933 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 934 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3kg / sqm including pointing the joints with white cement and matching pigment etc., complete. 935 providing and laying vitrified floor tiles in different sizes ( thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3kg / sqm including grouting the joints with white cement and matching pigments etc., complete. 936 size of tile 600x600 mm 937 providing and laying vitrified tiles in different sizes ( thickness to be specified by manufacturer ) , with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 ( 1cement: 3 coarse sand ) , jointing with grey cement slurry @ 3.3kg / sqm including grouting the joint with white cement & matching pigments etc. complete. 938 size of tile 400x400 mm 939 roofing 940 providing and laying brick tiles over mumty roofs, grouted with cement mortar 1:3 ( 1 cement : 3 fine sand ) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 ( 1 cement : 3 fine sand ) and finished neat. 941 with common burnt clay f.p.s. ( non modular ) brick tilesof class designation 10 942 making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size ) over p.v.c. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 ( 1 cement : 3 coarse sand ) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 943 finishing 944 12 mm cement plaster of mix 945 1:6 ( 1 cement: 6 coarse sand ) 946 15 mm cement plaster on rough side of single or half brick wall of mix: 947 1:6 ( 1 cement: 6 coarse sand ) 948 cement plaster 1:3 ( 1 cement: 3 coarse sand ) finished with a floatingcoat of neat cement. 949 20 mm cement plaster 950 6mm cement plaster of mix 951 1:3 ( 1 cement : 3 fine sand ) 952 white washing with lime to give an even shade : 953 new work ( three or more coats ) 954 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 955 new work ( two or more coats ) over and including water thinnable priming coat with cement primer 956 finishing walls with premium acrylic smooth exterior paint withsilicone additives of required shade: 957 new work ( two or more coats applied @ 1.43 ltr / 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm ) 958 applying priming coat: 959 with ready mixed pink or grey primer of approved brand and manufacture on wood work ( hard and soft wood ) 960 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron / steel works 961 painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 962 two or more coats on new work 963 painting with black anti corrosive bitumastic paint of approved brand and manufacture to give an even shade : 964 two or more coats on new work 965 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 966 water proofing 967 providing and laying in situ seven course water proofing treatment with app ( atactic poly propylene ) modified polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 kg / sqm, which shall consist of blown type bitumen of grade 85 / 25 conforming to is : 702, 3rd and 5th layers of roofing membrane app modified polymeric membrane 1.5 mm thick of 2.25 kg / sqm weight consisting of five layers prefabricated with centre core as 20 micron hmhdpe film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron hmhdpe film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 ( 1cement : 3 fine sand ) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 ( 1 cement : 3 fine sand ) and finished neat ( item of laying brick tiles shall be paid for separately ) . 968 applying a slurry coat of neat cement using 2.75 kg / sqm of cement admixed with water proofing compound conforming to is. 2645 and approved by engineer in charge over the rcc slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. 969 laying brick bats with mortar using broken bricks / brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 ( 1 cement : 5 coarse sand ) admixed with water proofing compound conforming to is : 2645 and approved by engineerin charge over 20 mm thick layer of cement mortar of mix 1:5 ( 1 cement :5 coarse sand ) admixed with water proofing compound conforming to is : 2645 and approved by engineerin charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. 970 after two days of proper curing applying a second coat of cement slurry using 2.75 kg / sqm of cement admixed with water proofing compound conforming to is : 2645 and approved by engineer in charge. 971 finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 ( 1 cement :4 coarse sand ) admixed with water proofing compound conforming to is : 2645 and approved by engineer in charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. 972 the whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“all above operations to be done in order and as directed and specified by the engineer in charge : 973 providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of w.c., kitchen and the like consisting of: 974 ist course of applying cement slurry @ 4.4 kg / sqm mixed with water proofing compound conforming to is 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. 975 iind course of 20 mm cement plaster 1:3 ( 1 cement : 3 coarse sand ) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. 976 iiird course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. 977 ivth course of 400 micron thick pvc sheet. ( overlaps at joints of pvc sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg / sqm ) . 978 non shedule items 979 providing and laying cinder filling in sunken floors and other locationswith approved quality cinder including watering and light ramming etc.required for proper compaction / completion of the work complete in all respects as per drawings and as directed by the engineer in charge. 980 providing and fixing aluminium handles, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 981 150 mm 982 providing and fixing aluminium door buffer of approved make, design and colour with necessary screws etc all complete as directed and specified by the engineer in charge : 983 providing and laying 1st quality ceramic glazed anti skid floortiles of size 300x300 mm ( thickness to be specified by the manufacturer ) conforming to is:15622 in all colours, shades, sizes as approved over 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand ) including pointing the joints with white cement and matching pigment etc complete in all respects as per specifications / drawings and to the entire satisfaction to the architect. 984 staff quarter ii ( g+1 ) 985 earth work 986 earth work in excavation by mechanical means ( hydraulic excavator ) / manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 sqm on plan ) , including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 987 all kinds of soil. 988 excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 989 all kinds of soil 990 pipes, cables etc, not exceeding 80 mm dia. 991 pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 992 filling available excavated earth ( excluding rock ) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 993 roofing 994 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, ( i ) single socketed pipes. 995 110 mm diameter 996 providing and fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 997 coupler 998 110 mm 999 bend 87.5° 1000 110 mm bend 1001 shoe ( plain ) 1002 110 mm shoe 1003 providing and fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with m.s. screws of required length, including cutting brick work and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand ) and making good the wall etc. complete. 1004 110 mm 1005 providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 1006 sanitary installations 1007 providing and fixing water closet squatting pan ( indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1008 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 1009 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. 1010 w.c. pan with isi marked white solid plastic seat and lid 1011 providing and fixing wash basin with c.i. brackets, 15 mm c.p. brass pillar taps, 32 mm c.p. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 1012 white vitreous china flat back wash basin size 550x 400 mm with single 15 mm c.p. brass pillar tap 1013 providing and fixing stainless steel a isi 304 ( 18 / 8 ) kitchen sink as per is: 13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 1014 kitchen sink with drain board 1015 510x1040 mm bowl depth 250 mm 1016 extra for using coloured pedestal type w.c pan ( european type ) with low level cistern of same colour instead of white vitreous china w.c pan and cistern. 1017 providing and fixing 600x450 mm beveled edge mirror of superior glass ( of approved quality ) complete with 6 mm thick hard board ground fixed to wooden cleats with c.p. brass screws and washers complete. 1018 providing and fixing toilet paper holder : 1019 vitreous china 1020 providing and fixing soil, waste and vent pipes : 1021 100 mm dia. 1022 centrifugally cast ( spun ) iron socket & spigot ( s&s ) pipe as per is: 3989 1023 75mm diameter 1024 centrifugally cast ( spun ) iron socketed pipe as per is: 3989 1025 providing and fixing m.s. holder bat clamps of approved design to sand cast iron / cast iron ( spun ) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) , including cost of cutting holes and making good the walls etc. : 1026 for 100 mm dia. pipe 1027 for 75 mm dia. pipe 1028 providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 1029 100 mm 1030 sand cast iron s&s as per is 3989 1031 75 mm 1032 sand cast iron s&s as per is 3989 1033 providing and fixing plain bend of required degree. 1034 100 mm 1035 sand cast iron s&s as per is : 3989 1036 75 mm 1037 sand cast iron s&s as per is 3989 1038 providing and fixing heel rest sanitary bend 1039 100 mmdia 1040 sand cast iron s&s as per is 3989 1041 75 mm dia 1042 sand cast iron s&s as per is 3989 1043 providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 1044 100x100x100mm 1045 sand cast iron s&s as per is 3989 1046 75x75x75mm 1047 sand cast iron s&s as per is 3989 1048 providing and fixing single equal plain junction of required degree 1049 100x100x100mm 1050 sand cast iron s&s as per is 3989 1051 75x75x75mm 1052 sand cast iron s&s as per is 3989 1053 providing and fixing door piece, insertion rubber washer 3mm thick, bolts & nuts complete : 1054 100 mm 1055 sand cast iron s&s as per is 3989 1056 75 mm 1057 sand cast iron s&s as per is 3989 1058 providing and fixing terminal guard : 1059 100 mm 1060 sand cast iron s&s as per is 3989 1061 75 mm 1062 sand cast iron s&s as per is 3989 1063 providing and fixing collar : 1064 100 mm 1065 sand cast iron s&s as per is 3989 1066 75 mm 1067 sand cast iron s&s as per is 3989 1068 providing lead caulked joints to sand cast iron / centrifugally cast ( spun ) iron pipes and fittings of diameter : 1069 100 mm 1070 75 mm 1071 providing and fixing m.s. stays and clamps for sand cast iron / centrifugally cast ( spun ) iron pipes of diameter : 1072 100 mm 1073 75 mm 1074 providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 1075 100 mm inlet and 100 mm outlet 1076 sand cast iron s&s as per is: 1729 1077 cutting chases in brick masonry walls for following diameter sand cast iron / centrifugally cast ( spun ) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size ) , including necessary plaster and pointing in cement mortar 1:4 ( 1 cement : 4 coarse sand ) : 1078 100 mm dia 1079 painting sand cast iron / centrifugally cast ( spun ) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer ( of approved quality ) for new work : 1080 100 mm diameter pipe 1081 75 mm diameter pipe 1082 providing and fixing ptmt waste coupling for wash basin and sink, of approved quality and colour. 1083 waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms 1084 providing and fixing ptmt bottle trap for wash basin and sink. 1085 bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms 1086 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 1087 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour. 1088 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 1089 providing and fixing g.i. pipes complete with g.i. fittings including trenching & refilling. 1090 external work 1091 32mmdia nominal bore 1092 40mmdia nominal bore 1093 50mmdia nominal bore 1094 water supply 1095 providing and fixing chlorinated polyvinyl chloride ( cpvc ) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 1096 internal work exposed on wall 1097 25 mm nominal outer dia pipes metre 1098 32 mm nominal outer dia pipes metre 1099 providing and fixing chlorinated polyvinyl chloride ( cpvc ) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i / c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 1100 concealed work, including cutting chases and making good the walls etc. 1101 15 mm nominal outer dia pipes 1102 20 mm nominal outer dia pipes 1103 making connection of g.i. distribution branch with g.i. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 1104 25 to 40 mm nominal bore 1105 providing and fixing brass stop cock of approved quality : 1106 15 mm nominal bore 1107 20 mm nominal bore 1108 providing and fixing gun metal gate valve with c.i. wheel of approved quality ( screwed end ) : 1109 25mm nominal bore 1110 32mm nominal bore 1111 40mm nominal bore 1112 providing and fixing ball valve ( brass ) of approved quality, high or low pressure, with plastic floats complete : 1113 25 mm nominal bore 1114 providing and fixing brass ferrule with c.i. mouth cover including boring and tapping the main : 1115 25 mm nominal bore 1116 providing and fixing uplasticised pvc connection pipe with brass unions : 1117 45 cm length 1118 15 mm nominal bore 1119 providing and fixing c.p. brass shower rose with 15 or 20 mm inlet : 1120 100 mm diameter 1121 providing and placing on terrace ( at all floor levels ) polyethylene water storage tank, is : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 1122 rectangular tank 1123 providing and fixing c.p. brass bib cock of approved quality conforming to is:8931 : 1124 15 mm nominal bore 1125 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 1126 15 mm nominal bore 1127 providing and fixing c.p. brass stop cock ( concealed ) of standard design and of approved make conforming to is:8931. 1128 15 mm nominal bore. 1129 providing and fixing c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 1130 15 mm nominal bore 1131 providing and fixing ptmt grating of approved quality and colour. 1132 circular type. 1133 100 mm nominal dia. 1134 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) , including finishing complete so as to make it leak proof. 1135 sewarage & drainage 1136 providing, laying and jointing glazed stoneware pipes class sp 1 with stiff mixture of cement mortar in the proportion of 1:1 ( 1 cement : 1 fine sand ) including testing of joints etc. complete : 1137 100 mm diameter 1138 150 mm diameter 1139 providing and laying cement concrete 1:5:10 ( 1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size ) all round s.w. pipes including bed concrete as per standard design : 1140 100 mm diameter s.w. pipe 1141 150 mm diameter s.w. pipe 1142 providing and fixing square mouth s.w. gully trap class sp 1 complete with c.i. grating brick masonry chamber with water tight c.i. cover with frame of 300 x300 mm size ( inside ) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70kg as per standard design: 1143 150 x 100 mm size p type 1144 with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 1145 constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with r.c.c. top slab with 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) , foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size ) , inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand ) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design : 1146 inside size 90x80 cm and 45 cm deep including c.i. cover with frame ( light duty ) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg ( weight of cover 23 kg and weight of frame 15 kg ) : 1147 with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 1148 extra for depth for manholes : 1149 size 90x80 cm 1150 with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 1151 providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per is : 10910, on 12 mm dia steel bar conforming to is: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) complete as per design. 1152 making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) cement plastered on both sides with cement mortar 1:3 ( 1 cement : 3 coarse sand ) , finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 1153 for pipes 100 to 250 mm diameter 1154 providing, laying and jointing non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete : 1155 150 mm dia rcc pipe 1156 250 mm dia rcc pipe 1157 sq type ii ( g+1 ) 1158 subhead i wiring 1159 wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. 1160 group c 1161 wiring for light / power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 1162 supplying and fixing following size / modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 1163 4 module ( 125 mmx75 mm ) 1164 supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1165 15 / 16 a switch 1166 3 pin 5 / 6 a socket outlet 1167 telephone socket outlet 1168 tv antenna socket outlet 1169 wiring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed steel conduit as required. 1170 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire 1171 2 x 10 sq. mm + 1 x 6 sq. mm earth wire 1172 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface / recessed steel / pvc conduit as required. 1173 supplying and fixing of following sizes of steel conduit along with accessories in surface / recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 1174 25 mm 1175 supplying and fixing following size / modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 1176 1 or 2 module ( 75 mmx75 mm ) 1177 supplying and drawing following pair 0.5 mm dia frls pvc insulated annealed copper conductor, unarmored telephone cable in the existing surface / recessed steel / pvc conduit as required. 1178 2 pair 1179 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. 1180 20 mm 1181 25 mm 1182 providing and fixing in position 2mm thick m.s. telephone junction box of size suitable for fixing of following krone tag block with key lock arrangement. also provide clamps for fixing tag blocks. 1183 10 pair telephone tag blockwith box 1184 supplying, laying of 10 pair unarmoured pvc insulated copper conductor ( atc ) telephone cable in ground / existing pipes / on wall and making connection with telephone main junction box ( mdf ) including supports and all accessories as required 1185 10 pair cable unarmoured 1186 subhead ii supply & installation of fittings 1187 supplying of following box type fl. fitting made out of crca sheet finished in antirust treated non yellowing super white stove enamelled paint duly wired with copper wound heavy duty choke starter holder, starter but without lamp complete etc. as reqd. 1188 mounting rail for tled lamps 1600 lumens ( tmc 501 p 1xt led with essential led 18w tube ) 1189 supplying of wall bracket light fittings suitable for 11 / 13 w cfl lamp. the fitting shall be made up of m.s. powder coated provided with integral ballast, frosted glass and 1 no. 11 / 13 wlamp duly wired upto the connector block complete as required. ( decon cat. no.05aam ) 1190 supplying of ceiling light fittings suitable for 1 x 15 / 20 w led lamp. the fitting shall be made up of m.s. powder coated provided with electronic ballast, 1 no. 15 / 20 w led lamp duly wired upto the connector block etc. complete as required. 1191 cirrus mini pro 15 / 20 watt & 1100 / 1600 lumens ( philips sm200c led11s 6500 psu od wh ) 1192 supplying of bulk head fittings suitable for 10 w led lamp complete with ballast & accessories such as glass, wire guard, 60 w cfl lamp etc. complete as required. 1193 endural led bulkhead, 10 w, 600 lumen such as ( philips wt202w led6s cw psu s2 pc ) 1194 supplying of exhaustfan, all complete with mounting ring frame i / c bracket, but without regulator with shutters in the following sizes. ( g.e. alsthom, khaitan & havells company ) 1195 300 mm 4 pole 1196 supplying of 1400 mm sweep a.c. electric ceiling fans, capacitor type with double ball bearing complete with 300 mm down rod, canopies, shackles, blades, but without regulator suitable for operation on 230 / 240 volts, 50 hz, single phase, a.c. supply. ( crompton, khaitan & havells company ) 1197 supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 1198 installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 1199 installation, testing and commissioning of pre wired, light fixture / compact fluorescent fitting of all types, complete with all accessories and tube / lamp etc. directly on ceiling / wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 1200 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 1201 upto 450 mm sweep 1202 extra for fixing the louvers / shutters complete with frame for a exhaust fan of all sizes. 1203 installation, testing and commissioning of wall bracket / ceiling fittings of all sizes and shapes containing upto two gls / cfl / led lamps per fitting, complete with all accessories including connections etc. as required. 1204 supplying and fixing call bell / buzzer suitable for single phase, 230 v, complete as required. 1205 subhead iii distribution board 1206 supplying, installing, testing and commissioning of compartmentalised cubical type meter board for installation of single phase meter. the cubical board shall be made of 2mm thick c.r.c.a sheet, duly phosphatised powder coated complete with connection bus bar and following accessories mounted in it. 1207 meter board 1208 incoming : 1209 40a tp mccb having breaking capacity 25 ka 1 no. 1210 outgoing : 1211 space for single phase energy meter 4 nos. 1212 25 amp dp mcb 4 nos. 1213 supplying, installing, testing & commissioning of single phase electronic energy meter, tested as per electricity boards requirement. 1214 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 1215 12 way, spn 1216 supplying and fixing following rating, double pole, 240 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 1217 40 amps 1218 supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. asrequired. 1219 25 amps 1220 supplying of xlpe insulated, pvc sheathed 1.1 kv grade aluminium conductor heavy duty armoured cable as per is : 7098 of size : 1221 4 x 16 sq.mm. 1222 providing, laying and fixing following dia rcc pipe np2 class ( light duty ) in ground complete with rcc collars, jointing with cement mortar 1:2 ( 1 cement : 2 fine sand ) including trenching ( 75 cm deep ) and refilling etc. as required for crossing road / walls 1223 100 mm dia 1224 supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 1225 single pole 1226 subhead iv earthing 1227 earthing with g.i. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. 1228 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re filling as required. 1229 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 1230 subhead v lightning conductor 1231 providing and fixing of lightning conductor finial, made of 25mm dia 300 mm long, g.i. tube, having single prong at top, with85 mm dia 6 mm thick g.i. base plate including holes etc.complete as required. 1232 jointing copper / g.i. tape ( with another copper / g i tape, base of the finial or any other metallic object ) by riveting / nut bolting / sweating and soldering etc as required. 1233 fixing of copper / g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( for horizontal run ) 1234 fixing of copper / g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( for vertical run ) 1235 providing and fixing testing joint, made of 20 mm x 3 mm thickg.i. strip, 125 mm long, with 4 nos. of g.i. bolts, nuts, chucknuts and spring washers etc. complete as required. 1236 laying copper / g.i. tape 32 mm x 6 mm from earth electrodedirectly in ground as required 1237 leveling 1238 2.00 mtr. width. pathway 1239 earth work in excavation by mechanical means ( hydraulic excavator ) / manual means over areas ( exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan ) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. 1240 all kinds of soil 1241 filling available excavated earth ( excluding rock ) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 1242 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. all work upto plinth level. 1243 1:5:10 ( 1 cement : 5 coarse sand ( zone iii ) : 10 graded stone aggregate 40 mm nominal size ) . 1244 c / s for mass concrete 1245 providing and laying 60mm thick faciory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved s;ze, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of engineer in charge. 1246 providing and laying at or near ground level factory made kerb stone of m 25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 ( 1 cement: 3 coarse sand ) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5mm ) , including making drainage opening wherever required complete etc. as per direction of engineer in charge ( length of finished kerb edging shall be measured for payment ) . ( precast c.c. kerb stone shall be approved by engineer in charge ) . 1247 15 mm plaster 1.4 1248 preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re rolling the sub grade and disposal of surplus earth with lead upto 50 metres. 1249 supplying and stacking at site. 1250 90 mm to 45 mm size stone aggregate 1251 63 mm to 45 mm size stone aggregate 1252 stone screening 13.2 mm nominal size 1253 stone screening 11.2 mm nominal size 1254 red bajri 1255 moorum 1256 providing and applying tack coat using hot straight run bitumen of grade vg 10, including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications : 1257 on w.b.m. @ 0.75 kg / sqm 1258 2.5 cm premix carpet surfacing with 2.25 cum and 1.12 cum of stone chippings of 13.2 mm and 11.2 mm size respectively per 100 sqm and 52 kg and 56 kg of hot bitumen per cum of stone chippings of 13.2 mm and 11.2 mm size respectively, including a tack coat with hot straight run bitumen, including consolidation with road roller of 6 to 9 tonne capacity etc. complete ( tack coat to be paid for separately ) . 1259 with paving asphalt grade vg 10 heated and then mixed with solvent at the rate of 70 grams per kg of asphalt 1260 providing and laying seal coat of premixed fine aggregate ( passing 2.36 mm and retained on 180 micron sieve ) with bitumen using 128kg of bitumen of grade vg 10 bitumen per cum of fine aggregate and 0.60 cum of fine aggregate per 100 sqm of road surface, including rolling and finishing with road roller all complete. 1261 laying, spreading and compacting stone aggregate of specified sizes to wbm specifications in uniform thickness, hand picking, rolling with 3 wheeled road / vibratory roller 8 10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density . 1262 qty same as 63 45 mm size stone aggregate 1263 qty same as 90 45 mm size stone aggregate 1264 providing and laying at or near ground level factory made kerb stone of m 25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 ( 1 cement: 3 coarse sand ) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5mm ) , includingmaking drainage opening wherever required complete etc. as per direction of engineer in charge ( length of finished kerb edging shallbe measured for payment ) . ( precast c.c. kerb stone shall be approved by engineer in charge ) . 1265 excavating, supplying and filling of local earth ( including royalty ) by mechanical transport upto a lead of 5km also including ramming andwatering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 1266 all kinds of soil 1267 total cost for 35.00 sqm 1268 external water supply 1269 external fresh water supply 1270 excavating trenches upto 1.5 meter depth in all kind ofsoil of required width for pipes. including excavation for sockets and dressing of sides ramming of bottoms including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m or as directed at site by engg in charge. 1271 all kinds of soil 1272 pipes, cables etc, not exceeding 80 mm dia. 1273 providing and fixing chlorinated polyvinyl chloride ( cpvc ) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings. this includes jointing of pipes & fittings with one step cpvc solvent cement, trenching, refilling & testing of joints complete as per direction of engineer in charge : external work 1274 external work 1275 25 mm dia nominal bore 1276 for vertical 1277 type 2 ( g ) ( 3+5 ) = 8 meter 1278 type guest house ( 3+5 ) = 8 meter 1279 32 mm dia nominal bore for horizontal surface 1280 for vertical 1281 type iii ( 3+5 ) = 8meter 1282 type ii ( 3x3+5+3+5 ) = 22 meter 1283 40 mm dia nominal bore 1284 50 mm dia nominal bore 1285 providing and fixing gun metal non return valve of approved quality ( screwed end ) : 1286 32 mm nominal bore 1287 horizontal 1288 construction of masonary chamber60x60x75 inside in brickwork cement mortar 1.6 1289 with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 1290 providing and fixing c.i. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete ( the tail pieces, tapers etc if required will be paid separately ) : 1291 50 mm dia 1292 50 mm dia 1293 100 mm dia 1294 providing and fixing gun metal gate valve with c.i. wheel of approved quality ( screwed end ) : 1295 25 mm nominal bore 1296 32 mm nominal bore 1297 40 mm nominal bore 1298 50 mm nominal bore 1299 providing and laying in position cement concreteof specified grade excluding the cost of centering and shuttering ( for thrust blocks at bends and junctions of water lines ) by 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone agg. 20 mm nominal size ) 1300 providing and fixing g.i. union in gi pipe including cutting and threading the pipe and making long screws etc. complete ( new work ) 1301 25 mm nominal bore 1302 32 mm nominal bore 1303 40 mm nominal bore 1304 50 mm nominal bore 1305 providing and fixing in position pre cast r.c.c. manhole cover and frame of required shape and approved quality 1306 ld 2.5 1307 rectangular shape 600*450 mm internal dimensions 1308 external sewer line 1309 external sewer line 1310 earth work in excavation by mechanical means ( hydraulic excavator ) / manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 sqm on plan ) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1311 excavating trenches of required width for pipes, cable, etcincluding excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.50m including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. 1312 all kinds of soil 1313 pipes cables etc. exceeding 80 mm dia. but not exceeding 300mm dia. 1314 pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm 1315 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level 1316 1:4:8 ( 1 cement : 4 coarse sand ( zone iii ) : 8 graded stone aggregate 40 mm nominal size ) 1317 providing and laying non pressure np2 class ( light duty ) r.c.c. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete : 1318 150 mm dia. r.c.c. pipe 1319 250 mm dia. r.c.c. pipe 1320 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 1321 1:5:10 ( 1 cement : 5 coarse sand ( zone iii ) : 10 graded stone aggregate 40 mm nominal size ) . 1322 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) 1323 providing and laying non pressure np2 class ( light duty ) r.c.c. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1cement : 2 fine sand ) including testing of joints etc. complete : 1324 300 mm dia. r.c.c. pipe 1325 450 mm dia. r.c.c. pipe 1326 centering and shuttering including strutting, propping etc. and removal of form for : 1327 foundations, footings, bases of columns, etc. for mass concrete. 1328 constructing brick masonry manholein cement mortar 1 : 4 ( 1 cement : 4 coarse sand ) with rcc top slab with 1 : 2 : 4 mix ( 1 cement : 2 coarse sand : 4gradestone aggregate 20mm nominal size ) ; foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 gradedstoneaggregate40 mm nominalsize ) insideplastering 12 mm thickwith cementmortar 1:3 ( 1cement 3 coarse sand ) finished with a floating coat of neat cement and makingchannels incementconcrete 1:2:4 ( 1cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size ) finishd with a floating coat ofneatcement completeasper standard design 1329 inside size 90 x 80 cm & 45 cmdeep including ci cover with frame ( light duty ) 455 x 610mm internal dimensions, total weight of cover & frame to be not lessthan 38 kg ( weight of cover 23 kg and weight of frame 15 kg ) 1330 with common burnt clay f.p.s. ( non modular ) bricks of classic designation 7.5 1331 inside size 120 x 90 cm & 90 cmdeep including ci cover with frame ( medium duty ) 560mm internal diameter, total wt. of cover & frame to be not lessthan 208 kg ( wt. of cover 108 kg and wt. of frame 100 kg ) 1332 with common burnt clay f.p.s. ( non modular ) bricks of classic designation 7.5 1333 extra for depth for manholes: 1334 size 90 x 80 cm 1335 with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 1336 size 120 x 90 cm 1337 with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 1338 providing and fixing square mouths. w. gully trapclass sp 1 complete with c.i. gratingbrickmasonry chamber with water tight ci cover with frame of 300 x 300 mm size ( inside ) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 1339 180 x 150 mm. size p type 1340 with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 1341 constructing brick masonry circular type manhole 0.91m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 ( 1 cement :4 coarse sand ) , in side cement plaster 12 mm thick with cement mortar 1:3 ( 1cement : 3 coarse sand ) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size ) , and making necessary channel in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) finished with a floating coat of neat cement, all complete as per standard design : 1342 circular manhole internal dia 0.91mtr. 1343 constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 ( 1 cement :4 coarse sand ) inside cement plaster 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand ) finished with a floating coat of neat cement foundation concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) and making necessary channel in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement, all complete as per standard design : 1344 1.68 m deep with sfrc cover and frame ( heavy duty hd 20 grade designation ) 560 mm internal diameter conforming to i.s. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) including centering, shuttering all complete. ( excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately ) : 1345 with sewer bricks conforming is : 4885 1346 extra depth for circular type manhole 1.22 m internal dia ( at bottom ) beyond 1.68 m to 2.29 m : 1347 12 mm cement plaster of mix: 1348 1:4 ( 1 cement: 4 fine sand ) 1349 constructing brick masonry circular manhole 1.52 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 ( 1 cement : 4 coarse sand ) inside cement plaster 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand ) finished with a floating coat of neat cement, foundation concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) and making necessary channel in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement, all complete as per standard design : 1350 2.30 m deep with sfrc cover and frame ( heavy duty hd 20 grade designation ) 560 mm internal diameter conforming to i.s. 12592, total weight of cover and frame to be not less than 182 kg. fixed in cement concrete 1:2:4 ( 1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) including centering, shuttering all complete. ( excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately ) : 1351 with sewer bricks conforming is : 4885 1352 extra depth for circular type manhole 1.52 m internal dia ( at bottom ) beyond 2.30 m : 1353 with sewer bricks conforming is : 4885 1354 12 mmcement plaster of mix 1355 1:4 ( 1 cement : 4 coarse sand ) . 1356 providing m.s. foot restsorange colour safety footrest 1357 with 20x20 mm square bar 1358 filling available excavated earth ( excluding rock ) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 1359 drain ( 230mm x 150mm ) 1360 earth work in excavation by mechanical means ( hydraulic excavator ) / manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 sqm on plan ) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1361 all kinds of soil. 1362 filling available excavated earth ( excluding rock ) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ( 40% of item no. 1 ) 1363 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 1364 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) 1365 1:5:10 ( 1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size ) . 1366 brick work with f.p.s. bricks of class designation 75 in foundation and plinth in: 1367 cement mortar 1:6 ( 1 cement : 6 coarse sand ) 1368 12 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 1369 1:4 ( 1 cement: 4 fine sand ) 1370 drain ( 300mm x 450mm ) 1371 earth work in excavation by mechanical means ( hydraulic excavator ) / manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 sqm on plan ) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1372 all kinds of soil. 1373 filling available excavated earth ( excluding rock ) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ( 40% of item no. 1 ) 1374 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 1375 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) 1376 1:5:10 ( 1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size ) 1377 brick work with f.p.s. bricks of class designation 75 in foundation and plinth in: 1378 cement mortar 1:6 ( 1 cement : 6 coarse sand ) 1379 12 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 1380 1:4 ( 1 cement: 4 fine sand ) 1381 h.t. / l.t. panel & feeder pillars 1382 sub feeder panel 1383 incoming 1384 mccb 200a 35ka tpn 1385 indication light 1386 bus bar feeders 1387 200amp alu.bus bar tpn 1388 out going 1389 g / d phase b mccb 125a 35ka tpn 1390 b / d phase b mccb 125a 35ka tpn 1391 type 3 ( g+1 ) mccb 63a 35ka tpn 1392 type 5 mccb 32a 35ka tpn 1393 guest house mccb 32a 35ka tpn 1394 type 3 ( g+2 ) mccb 63a 35ka tpn 1395 type 2 ( g+2 ) mccb 63a 35ka tpn 1396 spare 1397 emergency section 1398 incoming 1399 mcb 125a 63ka tpn 1400 out going 1401 b / d phase b mcb 63a 35ka dp 1402 g / d phase b mcb 63a 35ka dp 1403 type 3 ( g+1 ) mcb 32a 35ka dp 1404 type 5 mcb 32a 35ka dp 1405 guest house mcb 32a 35ka dp 1406 type 3 ( g+2 ) mccb 32a 35ka dp 1407 type 2 ( g+1 ) mccb 32a 35ka dp 1408 type 2 ( g ) mccb 32a 35ka dp 1409 spare 1410 enclosure 1411 panel body fabricated in 14 / 16 swg crca sheet , powder coa ted in siemence grey colour complete in all respects universal gland plates. 1412 meter panel ( type 2 / type3 / guest house ) 1413 incoming 1414 mcb 32a 10 ka tpn 1415 indication light r, y, b 1416 bus bar feeders 1417 100amp alu.bus bar tpn 1418 out going 1419 single phase energy meter 1420 mcb 25a dp 1421 emergency section 1422 incoming 1423 mccb 32a dp 1424 out going 1425 16a dp 1426 enclosure 1427 panel body fabricated in 14 / 16 swg crca sheet , powder coa ted in siemence grey colour complete in all respects universal gland plates. 1428 meter panel ( type 3 block b ) 1429 incoming 1430 mcb 63a 10 ka tpn 1431 indication light r, y, b 1432 bus bar feeders 1433 100amp alu.bus bar tpn 1434 out going 1435 single phase energy meter 1436 mcb 25a dp 1437 emergency section 1438 incoming 1439 mccb 32a dp 1440 out going 1441 16a dp 1442 enclosure 1443 panel body fabricated in 14 / 16 swg crca sheet , powder coa ted in siemence grey colour complete in all respects universal gland plates. 1444 type ii single story only mcb & meter without bus bar 1445 external electrification 1446 supply installation, testing and commissioning of external post top lantern with following and complete as required. 1447 6m high ( 5.0m above ground ) 65mm dia gi pole as approved, adopting socket at top for fixture mentioned below, base plate 300x300x6mm and provision for mounting junction box etc. 1 set 1448 erection of pole in cement concrete 400x400x1000mm deep 1:3:6 ratio cement concrete foundation including excavation , refilling, secured with holding clamps, bolts, nuts, alighnment of poles casting etc. including 100 mm thick lean concrete shall be provided at the bottom. 1449 led type 50 watt ( street light ) light fittings of all types with allaccessories. 1450 suitable size control box with 1 no. incoming and 2 nos. outgoing terminals and 2 nos. tap out terminal with 1 no.5a hrc fuses complet 1 set 1451 suitable number ( s ) 40mm dia class b gi pipes ( s ) from above control box to upto 0.5 meter below ground level for power cable entry. 1452 lt cables 1453 supply of following size of 1.1 kv grade multicore aluminium cunductor pvc sheathed armoured cable as per is 1554. 1454 4 core 25 sqmm 1455 4 core 16 sqmm 1456 2 core 16 sqmm 1457 2 core 10 sqmm 1458 earthingwithgi earth pipe 4.50 meter long 40mm dia including accessories, and providing masonry enclosure with cover plate having lockingarrangement and watering pipe etc.with charcoal or coke and salt complete as required. 1459 earthingwithgi earth plate 600 x 600 x 3mmthickincluding accessories, and providing masonry enclosure with cover plate having lockingarrangement and watering pipe etc.ith watering pipeof 2.7 meter long etc. with charcoal or coke and salt complete as required. ( for mltp & dg body ) 1460 providing and fixing 25 mm x 5 mm copper strips in 40 mm dia g.i.pipe from earth electrode, including connection with brass nut bolts , spring washer, excavation and refilling etc, as required ( copper plate earthing ) 1461 providing and fixing 25 mm x 5 mm gi strip in 40 mm dia g.i.pipe from earth electrode, including connection with brass nut bolts , spring washer, excavation and refilling etc, as required ( copper gi plate earthing ) 1462 providing& layingearth connection from earth electrode with 6 swg dia giwire in 15 mm gi pipe from earth electrode including connection with gi thimbleexcavation and refilling etc as required. ( for gi pipe earthing ofpoles ) 1463 supply & laying of 25 x 5 mm copper earth strip in surface / recess 1464 providing and fixing 25mm x 5 mm g.i. strips on surface or in recess for connections etc. as required 1465 providing andfixing mvdanger noticeplate of200 mm x 150 mm madeofmild steelatleast 2 mm thickandvitreousenameled white on both sides & with inscription in signalred colour on front side as required. ( on 7mts poles & panels ) 1466 lt cables laying 1467 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc / hume / metal pipe as required. 1468 upto 35 sq. mm 1469 above 35 sq. mm and upto 95 sq. mm 1470 above 95 sq. mm and upto 185 sq. mm 1471 above 185 sq. mm and upto 400 sq. mm 1472 supplying and laying of following size dwc hdpe pipe isi marked along with all accessories like socket, bend, couplers etc. conforming to is 14930, part ii complete with fitting and cutting, jointing etc.direct in ground ( 75 cm below ground level ) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 1473 63 mm dia ( od 63 mm & id 51 mm nominal ) 1474 120 mm dia ( od 120 mm & id 103 mm nominal ) 1475 160 mm dia ( od 160 mm & id 135 mm nominal ) sqmm 1476 200 mm dia ( od 200 mm & id 175 mm nominal ) 1477 supplying and making end termination with brass comperession gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required 1478 4 core 25 sqmm 1479 4 core 16 sqmm 1480 3.5 core 240 sqmm 1481 3.5 core 95 sqmm 1482 2 core 50 sqmm 1483 2 core 16 sqmm 1484 2 core 10 sqmm 1485 excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 1486 ordinary rock 1487 pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. 1488 providing and laying non pressure np2 class ( light duty ) r.c.c. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete : 1489 150 mm dia. r.c.c. pipe 1490 earth work in excavation by mechanical means ( hydraulic excavator ) i manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 sqm on plan ) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1491 all kinds of soil.0.00 1.50m 1492 earth work in excavation by mechanical means ( hydraulic excavator ) i manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 sqm on plan ) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1493 all kinds of soil.1.50 3.00m 1494 filling available excavated earth ( excluding rock ) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 1495 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 1496 1:5:10 ( 1 cement : 5 coarse sand ( zone iii ) : 10 graded stone aggregate 40 mm nominal size ) . 1497 providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement all work up to plinth level: 1498 1:1.5:3 ( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size ) 1499 centering and shuttering including strutting, propping etc. and removal of form for: 1500 foundations, footings, bases of columns, etc. for mass concrete. 1501 walls ( any thickness ) including attached pilasters, butteresses, plinth and string courses etc. 1502 suspended floors, roofs, landings, balconies and access platform. 1503 lintels, beams, plinth beams, girders, bressumers and cantilevers. 1504 edges of slabs and breaks in floors and walls. 1505 under 20 cm wide 1506 reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete. 1507 thermo mechanically treated bars. 1508 cement concrete flooring 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate ) finished with a floating coat of neat cement, includingcement slurry, but excluding the cost of nosing of steps etc. complete. 1509 40 mm thick with 20 mm nominal size stone aggregate 1510 6 mm cement plaster of mix : 1511 1:3 ( 1 cement : 3 fine sand ) 1512 providing and fixing in position pre cast r.c.c. manhole cover and frame of required shape and approved quality 1513 hd 20 1514 circular shape 560 mm internal diameter 1515 providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per is : 10910 on 12mm dia steel bar conforming to is : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) complete as per design. 1516 providing and fixing soil, waste and vent pipes 1517 100 mm dia. 1518 centrifugally cast ( spun ) iron socketed pipe as per is: 3989. 1519 making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and s.w. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. 1520 with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 1521 dismantling work including credti items i.e bricks steels...

Uttar Pradesh Projects Corporation Limited - Bihar

42835557 construction of phase b works at jnv gaya ii ( bihar ) 1 earth work 2 earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 3 all kinds of soil 4 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 5 supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 6 excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 7 concrete work 8 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 9 1:5:10 (1 cement : 5 coarse sand (zone iii) : 10 graded stone aggregate 40 mm nominal size) 10 providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : 11 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). 12 providing and laying damp proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone iii): 4 graded stone aggregate 12.5mm nominal size) 13 providing & applying a coat of residual petroleum bitumen of grade of vg 10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 14 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 15 reinforcedcementconcrete 16 centering and shuttering including strutting, propping etc. and removal of form for all heights: 17 foundations, footings, bases of columns, etc. for mass concrete 18 columns, pillars, piers, abutments, posts and struts 19 small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like 20 edges of slabs and breaks in floors and walls 21 under 20 cms wide 22 suspended floors, roofs, landings, balconies and access platform. 23 lintels, beams, plinth beams, girders, bressumers and cantilevers. 24 providing precast cement concrete jali 1:2:4 (1 cement : 2 coarse sand(zone iii) : 4 graded stone aggregate 6mm nominal size), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing with cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits. 25 50 mm thick 26 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 27 thermo mechanically treated bars of grade fe 500d or more. 28 add for plaster drip course/ groove in plastered surface or moulding to r.c.c. projections. 29 providing and laying in position machine batched and machine mixed design mix m 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per is: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of engineer in charge.“(note : cement content considered in this item is @ 330 kg/cum.“excess/ less cement used as per design mix is payable/recoverable separately). 30 all works upto plinth level 31 all works above plinth level upto floor v level 32 add for using extra cement in the items of design mix over and above the specified cement content therein. 33 brick work 34 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in foundation and plinth in: 35 cement mortar 1:6 (1 cement : 6 coarse sand) 36 providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick aac blocks in super structure above plinth level up to floor v level with rcc band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of engineer in charge. (the payment of rcc band and reinforcement shall be made for seperately).: 37 half brick masonry with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level. 38 cement mortar 1:4 (1 cement :4 coarse sand) 39 extra for providing and placing in position 2 nos 6mm dia. m.s. bars at every third course of half brick masonry. 40 brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand). 41 marble work 42 providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 43 raj nagar plain white marble/ udaipur green marble/ zebra black marble 44 area of slab over 0.50 sqm 45 granite of any colour and shade 46 area of slab over 0.50 sqm 47 providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer in charge. 48 marble work 49 granite work 50 extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 51 wood work & pvc work 52 float glass panes 53 4mm thick glass pane (weight not less than 10 kg/sqm 54 extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. (area of opening for glass panes excluding portion inside rebate shall be measured). 55 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 56 35 mm thick including isi marked stainless steel butt hinges with necessary screws 57 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 58 extra for cutting rebate in flush door shutters (total area of the shutter to be measured). 59 providing and fixing wire gauge shutters using galvanized m.s. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 60 35 mm thick shutters 61 kiln seasoned and chemically treated hollock wood 62 providing and fixing fly proof galvanized m.s. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. 63 with 12 mm mild steel u beading 64 providing and fixing isi marked oxidised m.s. single acting spring hinges with necessary screws etc. complete : 65 150 mm 66 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete. 67 250 mm weighing not less than 150 gms 68 providing and fixing aluminium sliding door bolts, isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 69 250x16 mm 70 providing and fixing aluminium tower bolts, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 71 200x10 mm 72 providing and fixing aluminium hanging floor door stopper, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. 73 twin rubber stopper 74 providing and fixing factory made upvc white colour sliding glazed window upto 1.50 m in height dimension comprising of upvc multi chambered frame with in built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to upvc profile), appropriate dimension of upvc extruded glazing beads and upvc extruded interlocks, epdm gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), g.i fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of engineer in charge. (single / double glass panes, wire mesh and silicon sealent shall be paid separately). variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 75 three track three panels sliding window with fly proof s.s wire mesh (two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (area of window above 1.75 sqm). 76 steel work 77 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 78 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 79 providing and fixing t iron frames for doors, windows and ventilators of mild steel tee sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 80 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 81 providing and fixing circular/ hexagonal cast iron or m.s. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick m.s. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ m.s. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. clamp shall be made of 12 mm dia m.s. bar bent to shape as per standard drawing. 82 providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. 83 m.s. tube 84 providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 85 4.0 mm thick glass panes 86 flooring 87 providing and laying c.c. pavement of mix m 25 with ready mixed concrete from batching plant. the ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of engineer incharge. (the panel shuttering work shall be paid for separately). 88 (note: cement content considered in this item is @ 330 kg/cum. excess/less cement used as per design mix is payable/ recoverable separately). 89 kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 90 25 mm thick. 91 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 92 extra for pre finished nosing in treads of steps of kota stone/ sand stone slab. 93 extra for kota stone/ sand stone in treads of steps and risers using single length up to 1.05 metre. 94 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 95 providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 96 size of tile 600x600 mm 97 providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. 98 size of tile 600x600 mm 99 providing and laying 60mm thick faciory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved s;ze, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of engineer in charge. 100 roofing 101 providing and laying brick tiles over mumty roofs, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat: 12.19.1 with common burnt clay f.p.s. (non modular) brick tilesof class designation 10 102 making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over p.v.c. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 103 finishing 104 12 mm cement plaster of mix 105 1:6 (1 cement: 6 coarse sand) 106 15 mm cement plaster on rough side of single or half brick wall of mix: 107 1:6 (1 cement: 6 coarse sand) 108 cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 109 20 mm cement plaster 110 white washing with lime to give an even shade : 111 new work (three or more coats) 112 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 113 new work (two or more coats) over and including water thinnable priming coat with cement primer 114 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 115 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 116 applying priming coat: 117 with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 118 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 119 painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 120 two or more coats on new work 121 painting with black anti corrosive bitumastic paint of approved brand and manufacture to give an even shade : 122 two or more coats on new work 123 water proofing 124 providing and laying water proofing treatment to vertical andhorizontal surfaces of depressed portions of w.c., kitchen and the like consisting of: 125 ist course of applying cement slurry @ 4.4 kg/sqm mixedwith water proofing compound conforming to is 2645 inrecommended proportions including rounding off junction ofvertical and horizontal surface. 126 iind course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. 127 iiird course of applying blown or residual bitumen applied hotat 1.7 kg. per sqm of area. 128 ivth course of 400 micron thick pvc sheet. (overlaps at jointsof pvc sheet should be 100 mm wide and pasted to eachother with bitumen @ 1.7 kg/sqm). 129 providing and laying in situ seven course water proofing treatment with app (atactic poly propylene) modified polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to is : 702, 3rd and 5th layers of roofing membrane app modified polymeric membrane 1.5 mm thick of 2.25 kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron hmhdpe film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron hmhdpe film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately). 130 non shedule items 131 providing and fixing aluminium handles, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 132 150 mm 133 providing and fixing aluminium door buffer of approved make, design and colour with necessary screws etc all complete as directed and specified by the engineer in charge : 134 providing and laying 1st quality ceramic glazed anti skid floortiles of size 300x300 mm (thickness to be specified by the manufacturer) conforming to is:15622 in all colours, shades, sizes as approved over 20 mm thick bed of cement mortar 1: 4 (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc complete in all respects as per specifications/drawings and to the entire satisfaction to the architect. 135 earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 136 all kinds of soil. 137 excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 138 all kinds of soil 139 pipes, cables etc, not exceeding 80 mm dia. 140 pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 141 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 142 roofing 143 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 144 110 mm diameter 145 providing and fixing on wall face unplasticised pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 146 coupler 147 110 mm 148 bend 87.5° 149 110 mm bend 150 shoe (plain) 151 110 mm shoe 152 providing and fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with m.s. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 153 110 mm 154 providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 155 sanitary installations 156 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 157 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 158 providing and fixing white vitreous china pedestal type water closet (european type) with seat and lid, 10 litre low level white vitreous china flushing cistern & c.p. flush bend with fittings & c.i. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 159 w.c. pan with isi marked black solid plastic seat and lid 160 providing and fixing wash basin with c.i. brackets, 15 mm c.p. brass pillar taps, 32 mm c.p. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 161 white vitreous china flat back wash basin size 550x 400 mm with single 15 mm c.p. brass pillar tap 162 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is: 13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 163 kitchen sink with drain board 164 510x1040 mm bowl depth 250 mm 165 extra for using coloured pedestal type w.c pan (european type) with low level cistern of same colour instead of white vitreous china w.c pan and cistern. 166 providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with c.p. brass screws and washers complete. 167 providing and fixing toilet paper holder : 168 vitreous china 169 providing and fixing soil, waste and vent pipes : 170 100 mm dia. 171 centrifugally cast (spun) iron socket & spigot (s&s) pipe as per is: 3989 172 75mm diameter 173 centrifugally cast (spun) iron socketed pipe as per is: 3989 174 providing and fixing m.s. holder bat clamps of approved design to sand cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : 175 for 100 mm dia. pipe 176 for 75 mm dia. pipe 177 providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 178 100 mm 179 sand cast iron s&s as per is 3989 180 75 mm 181 sand cast iron s&s as per is 3989 182 providing and fixing plain bend of required degree. 183 100 mm 184 sand cast iron s&s as per is : 3989 185 75 mm 186 sand cast iron s&s as per is 3989 187 providing and fixing heel rest sanitary bend 188 100 mmdia 189 sand cast iron s&s as per is 3989 190 75 mm dia 191 sand cast iron s&s as per is 3989 192 providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3mm thick,bolts and nuts complete. 193 100x100x100mm 194 sand cast iron s&s as per is 3989 195 75x75x75mm 196 sand cast iron s&s as per is 3989 197 providing and fixing single equal plain junction of required degree 198 100x100x100mm 199 sand cast iron s&s as per is 3989 200 75x75x75mm 201 sand cast iron s&s as per is 3989 202 providing and fixing door piece, insertion rubber washer 3mm thick, bolts & nuts complete : 203 100 mm 204 sand cast iron s&s as per is 3989 205 75 mm 206 sand cast iron s&s as per is 3989 207 providing and fixing terminal guard : 208 100 mm 209 sand cast iron s&s as per is 3989 210 75 mm 211 sand cast iron s&s as per is 3989 212 providing and fixing collar : 213 100 mm 214 sand cast iron s&s as per is 3989 215 75 mm 216 sand cast iron s&s as per is 3989 217 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : 218 100 mm 219 75 mm 220 providing and fixing m.s. stays and clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter : 221 100 mm 222 75 mm 223 providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 224 100 mm inlet and 100 mm outlet 225 sand cast iron s&s as per is: 1729 226 cutting chases in brick masonry walls for following diameter sand cast iron/ centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : 227 100 mm dia 228 painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work : 229 75 mm diameter pipe 230 providing and fixing ptmt waste coupling for wash basin and sink, of approved quality and colour. 231 waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms 232 providing and fixing ptmt bottle trap for wash basin and sink. 233 bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms 234 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 235 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour. 236 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 237 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is: 13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 238 kitchen sink with drain board 239 510x1040 mm bowl depth 250 mm 240 providing and fixing 8mm dia c.p / s.s jet with flexible tube upto1 metre long with s.s triangular plate to eureopean type w.c of quality and make as approved by engineer in charge. 241 providing and fixing g.i. pipes complete with g.i. fittings including trenching & refilling. 242 external work 243 32mmdia nominal bore 244 40mmdia nominal bore 245 water supply 246 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 247 internal work exposed on wall 248 20 mm nominal outer dia pipes 249 25 mm nominal outer dia pipes 250 32 mm nominal outer dia pipes 251 40 mm nominal outer dia pipes 252 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 253 concealed work, including cutting chases and making good the walls etc. 254 15 mm nominal outer dia pipes 255 20 mm nominal outer dia pipes 256 25 mm nominal outer dia pipes 257 32 mm nominal outer dia pipes 258 making connection of g.i. distribution branch with g.i. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 259 25 to 40 mm nominal bore 260 providing and fixing brass stop cock of approved quality : 261 15 mm nominal bore 262 20 mm nominal bore 263 providing and fixing gun metal gate valve with c.i. wheel of approved quality (screwed end) : 264 25mm nominal bore 265 32mm nominal bore 266 40mm nominal bore 267 providing and fixing ball valve (brass) of approved quality, high or low pressure, with plastic floats complete : 268 25 mm nominal bore 269 providing and fixing brass ferrule with c.i. mouth cover including boring and tapping the main : 270 25 mm nominal bore 271 providing and fixing uplasticised pvc connection pipe with brass unions : 272 45 cm length 273 15 mm nominal bore 274 providing and fixing c.p. brass shower rose with 15 or 20 mm inlet : 275 100 mm diameter 276 providing and placing on terrace (at all floor levels) polyethylene water storage tank, is : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 277 rectangular tank 278 providing and fixing c.p. brass bib cock of approved quality conforming to is:8931 : 279 15 mm nominal bore 280 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 281 15 mm nominal bore 282 providing and fixing c.p. brass stop cock (concealed) of standard design and of approved make conforming to is:8931. 283 15 mm nominal bore. 284 providing and fixing c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 285 15 mm nominal bore 286 providing and fixing ptmt grating of approved quality and colour. 287 circular type. 288 100 mm nominal dia. 289 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 290 sewarage & drainage 291 providing, laying and jointing glazed stoneware pipes class sp 1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 292 100 mm diameter 293 150 mm diameter 294 providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all round s.w. pipes including bed concrete as per standard design : 295 100 mm diameter s.w. pipe 296 150 mm diameter s.w. pipe 297 providing and fixing square mouth s.w. gully trap class sp 1 complete with c.i. grating brick masonry chamber with water tight c.i. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70kg as per standard design: 298 180 x 150 mm size p type 299 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 300 constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with r.c.c. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : 301 inside size 90x80 cm and 45 cm deep including c.i. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : 302 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 303 extra for depth for manholes : 304 size 90x80 cm 305 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 306 providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per is : 10910, on 12 mm dia steel bar conforming to is: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 307 making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 308 for pipes 100 to 250 mm diameter 309 providing, laying and jointing non pressure np2 class (light duty)rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 310 150 mm dia rcc pipe 311 250 mm dia rcc pipe 312 non shedule items 313 providing and fixing concealed single leverbath & overhead shower mixer of hindware make and model no.(f360019cp) respectively or equivalent approved make as approved byengineer in charge. 314 providing & fixing sink mixer with swinging casted spout (wall mounted jaquar model con 309 kn)/approved equal with 450mm long copper pipes & brass nuts. 315 providing and fixing c.p. brass grab bar(600mm long) fixed with c.p. brass screwsincluding all fittings complete.jaquar model no. ahs 1507/approve equal. 316 subhead i wiring 317 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. 318 group c 319 wiring for light/ power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 320 wiring for light/ power plug with 4x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 nos. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 321 supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 322 4 module (125 mmx75 mm) 323 supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 324 15/16 a switch 325 3 pin 5/6 a socket outlet 326 telephone socket outlet 327 tv antenna socket outlet 328 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 329 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire 330 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 331 2 x 10 sq. mm + 1 x 6 sq. mm earth wire 332 4 x 4 sq. mm + 2 x 4 sq. mm earth wire 333 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface/ recessed steel/ pvc conduit as required. 334 supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 335 25 mm 336 supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 337 1 or 2 module (75 mmx75 mm) 338 supplying and drawing following pair 0.5 mm dia frls pvc insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ pvc conduit as required. 339 2 pair 340 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 341 20 mm 342 25 mm 343 providing and fixing in position 2mm thick m.s. telephone junction box of size suitable for fixing of following krone tag block with key lock arrangement. also provide clamps for fixing tag blocks. 344 10 pair telephone tag blockwith box 345 supplying, laying of 10 pair unarmoured pvc insulated copper conductor (atc) telephone cable in ground/existing pipes/on wall and making connection with telephone main junction box (mdf) including supports and all accessories as required 346 10 pair cable unarmoured 347 subhead ii supply & installation of fittings 348 supplying of following box type fl. fitting made out of crca sheet finished in antirust treated non yellowing super white stove enamelled paint duly wired with copper wound heavy duty choke starter holder, starter but without lamp complete etc. as reqd. 349 mounting rail for tled lamps 1600 lumens (tmc 501 p 1xt led with essential led 18w tube) 350 sereno 42 watt 2950 lumens philips sp824 p led 30s 5000 gr oa 351 supplying of wall mounted suitable for 1300 lumens complete with ballast & accessories such as wire guard etc. complete as required. 352 15w astra surface & wall mounted 1300 lumens ( philips bn150w led13s 6500 pse od gr ) 353 supplying of wall bracket light fittings suitable for 11 / 13 w cfl lamp. the fitting shall be made up of m.s. powder coated provided with integral ballast, frosted glass and 1 no. 11 / 13 wlamp duly wired upto the connector block complete as required. (decon cat. no.05aam) 354 supplying of ceiling light fittings suitable for 1 x 15/20 w led lamp. the fitting shall be made up of m.s. powder coated provided with electronic ballast, 1 no. 15/20 w led lamp duly wired upto the connector block etc. complete as required. 355 cirrus mini pro 15 / 20 watt & 1100 /1600 lumens (philips sm200c led11s 6500 psu od wh) 356 supplying of bulk head fittings suitable for 10 w led lamp complete with ballast & accessories such as glass, wire guard, 60 w cfl lamp etc. complete as required. 357 endural led bulkhead, 10 w, 600 lumen such as (philips wt202w led6s cw psu s2 pc) 358 supplying of exhaustfan, all complete with mounting ring frame i/c bracket,but without regulator with shutters in the following sizes. (g.e. alsthom, khaitan & havells company) 359 300 mm 4 pole 360 supplying of 1400 mm sweep a.c. electric ceiling fans, capacitor type with double ball bearing complete with 300 mm down rod, canopies, shackles, blades, but without regulator suitable for operation on 230 / 240 volts, 50 hz, single phase, a.c. supply. (crompton, khaitan & havells company) 361 supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 362 installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 363 installation, testing and commissioning of pre wired, light fixture / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 364 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 365 upto 450 mm sweep 366 extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. 367 installation, testing and commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two gls/cfl/ led lamps per fitting, complete with all accessories including connections etc. as required. 368 supplying and fixing call bell/ buzzer suitable for single phase, 230 v, complete as required. 369 subhead iii distribution board 370 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/ isolator) 371 6 way (4 + 18), double door 372 supplying and fixing following rating, four pole, 415 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 373 100 a 374 supplying and fixing following rating, four pole, (three phase and neutral), 415 v, residual current circuit breaker (rccb), having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. 375 63 a 376 supplying and fixing following rating, double pole, 240 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 377 40 amps 378 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 379 12 way , double door 380 16 way , double door 381 supplying and fixing following rating, double pole, (single phase and neutral), 240 v, residual current circuit breaker (rccb), having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. 382 25 a 383 40 a 384 supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 385 single pole 386 subhead iv earthing 387 earthing with g.i. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 388 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re filling as required. 389 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 390 subhead v street lighting on building 391 supplying, installing, testing and commissioning of 2 x 36w general purpose flourescent street light fittings with sheet aluminium housing and uv stabilized acrylic cover complete with chokes, starter holders, condensers, reflector cover etc. as reqd. (philips cat no. trc 33 / 236 hpf) (to be fixed directly on wall of building) 392 supplying and fixing of 32 mm dia x 2.00 meter long g.i. pipe (medium class) bracket for mounting of fluorescent / hpmv / hpsv street light fitting on pole including bending the pipe to the required shape, 2 nos. 40 mm x 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. 393 supply of following sizes of frls 1.1 kv stranded compact circular aluminium conductor screened with extruded semi conducting compound, xlpe insulated,al round wire armoured & overall pvc sheathed cableconforming to is to is 7098 (part i) with latest amendments 394 2 x 4 sq.mm 395 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. 396 upto 35 sq. mm 397 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc/ hume/ metal pipe as required. 398 upto 35 sq. mm 399 laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required. 400 upto 35 sq. mm (clamped with 1mm thick saddle) 401 supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required. 402 2 x 6 sq. mm (19mm) 403 supply & fixing of 150x200 mm 60mm deep ms junction box recess or surface on wall with 3mm bakalite cover15 overlapping 15 all sides of junction box & housing 4way 32amps bakelie connector to terminate incoming & outgoing armoured cable & & wiring the light fixture with 3x1.5 sq mm pvc insulated coppwer wire including interconnection ets as reqired .( cost of termination of armoured cable with gland is not to be included as the same is payable under separate item no 5.07 of this subhead) 404 providing, laying and fixing following dia rcc pipe np2 class (light duty) in ground complete with rcc collars, jointing withcement mortar1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required. 405 100 mm dia 406 subhead vi lightning conductor 407 providing and fixing of lightning conductor finial, made of 25mm dia 300 mm long, g.i. tube, having single prong at top, with85 mm dia 6 mm thick g.i. base plate including holes etc.complete as required. 408 jointing copper / g.i. tape (with another copper/ g i tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 409 fixing of copper/ g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for horizontal run) 410 fixing of copper/ g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for vertical run) 411 providing and fixing testing joint, made of 20 mm x 3 mm thickg.i. strip, 125 mm long, with 4 nos. of g.i. bolts, nuts, chucknuts and spring washers etc. complete as required. 412 laying copper/ g.i. tape 32 mm x 6 mm from earth electrodedirectly in ground as required 413 earth work 414 earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 415 all kinds of soil 416 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 417 supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 418 excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 419 concrete work 420 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 421 1:5:10 (1 cement : 5 coarse sand (zone iii) : 10 graded stone aggregate 40 mm nominal size) 422 providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : 423 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). 424 providing and laying damp proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone iii): 4 graded stone aggregate 12.5mm nominal size) 425 providing & applying a coat of residual petroleum bitumen of grade of vg 10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 426 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 427 reinforcedcementconcrete 428 centering and shuttering including strutting, propping etc. and removal of form for all heights: 429 foundations, footings, bases of columns, etc. for mass concrete 430 walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc 431 columns, pillars, piers, abutments, posts and struts 432 small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like 433 edges of slabs and breaks in floors and walls 434 under 20 cms wide 435 suspended floors, roofs, landings, balconies and access platform. 436 lintels, beams, plinth beams, girders, bressumers and cantilevers. 437 providing precast cement concrete jali 1:2:4 (1 cement : 2 coarse sand(zone iii) : 4 graded stone aggregate 6mm nominal size), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing with cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits. 438 50 mm thick 439 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 440 thermo mechanically treated bars of grade fe 500d or more. 441 add for plaster drip course/ groove in plastered surface or moulding to r.c.c. projections. 442 providing and laying in position machine batched and machine mixed design mix m 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per is: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of engineer in charge.“(note : cement content considered in this item is @ 330 kg/cum.“excess/ less cement used as per design mix is payable/recoverable separately). 443 all works upto plinth level 444 all works above plinth level upto floor v level 445 add for using extra cement in the items of design mix over and above the specified cement content therein. 446 brick work 447 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in foundation and plinth in: 448 cement mortar 1:6 (1 cement : 6 coarse sand) 449 providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick aac blocks in super structure above plinth level up to floor v level with rcc band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of engineer in charge. (the payment of rcc band and reinforcement shall be made for seperately).: 450 half brick masonry with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level. 451 cement mortar 1:4 (1 cement :4 coarse sand) 452 extra for providing and placing in position 2 nos 6mm dia. m.s. bars at every third course of half brick masonry. 453 brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand). 454 marble work 455 providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 456 raj nagar plain white marble/ udaipur green marble/ zebra black marble 457 area of slab over 0.50 sqm 458 granite of any colour and shade 459 area of slab over 0.50 sqm 460 providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer in charge. 461 marble work 462 granite work 463 extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 464 wood work & pvc work 465 float glass panes 466 4mm thick glass pane (weight not less than 10 kg/sqm 467 extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. (area of opening for glass panes excluding portion inside rebate shall be measured). 468 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 469 35 mm thick including isi marked stainless steel butt hinges with necessary screws 470 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 471 extra for cutting rebate in flush door shutters (total area of the shutter to be measured). 472 providing and fixing wire gauge shutters using galvanized m.s. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 473 35 mm thick shutters 474 kiln seasoned and chemically treated hollock wood 475 providing and fixing fly proof galvanized m.s. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. 476 with 12 mm mild steel u beading 477 providing and fixing isi marked oxidised m.s. single acting spring hinges with necessary screws etc. complete : 478 150 mm 479 providing and fixing oxidised m.s. casement stays (straight peg type) with necessary screws etc. complete. 480 250 mm weighing not less than 150 gms 481 providing and fixing aluminium sliding door bolts, isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 482 250x16 mm 483 providing and fixing aluminium tower bolts, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 484 200x10 mm 485 providing and fixing aluminium hanging floor door stopper, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. 486 twin rubber stopper 487 providing and fixing factory made upvc white colour sliding glazed window upto 1.50 m in height dimension comprising of upvc multi chambered frame with in built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to upvc profile), appropriate dimension of upvc extruded glazing beads and upvc extruded interlocks, epdm gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), g.i fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of engineer in charge. (single / double glass panes, wire mesh and silicon sealent shall be paid separately). variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 488 three track three panels sliding window with fly proof s.s wire mesh (two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (area of window above 1.75 sqm). 489 steel work 490 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 491 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 492 providing and fixing t iron frames for doors, windows and ventilators of mild steel tee sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 493 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 494 providing and fixing circular/ hexagonal cast iron or m.s. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick m.s. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ m.s. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. clamp shall be made of 12 mm dia m.s. bar bent to shape as per standard drawing. 495 providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. 496 m.s. tube 497 providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 498 4.0 mm thick glass panes 499 flooring 500 providing and laying c.c. pavement of mix m 25 with ready mixed concrete from batching plant. the ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of engineer incharge. (the panel shuttering work shall be paid for separately). 501 (note: cement content considered in this item is @ 330 kg/cum. excess/less cement used as per design mix is payable/ recoverable separately). 502 kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 503 25 mm thick. 504 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 505 extra for pre finished nosing in treads of steps of kota stone/ sand stone slab. 506 extra for kota stone/ sand stone in treads of steps and risers using single length up to 1.05 metre. 507 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 508 providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 509 size of tile 600x600 mm 510 providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. 511 size of tile 600x600 mm 512 providing and laying 60mm thick faciory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved s;ze, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of engineer in charge. 513 roofing 514 providing and laying brick tiles over mumty roofs, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat: 12.19.1 with common burnt clay f.p.s. (non modular) brick tilesof class designation 10 515 making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over p.v.c. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 516 finishing 517 12 mm cement plaster of mix 518 1:6 (1 cement: 6 coarse sand) 519 15 mm cement plaster on rough side of single or half brick wall of mix: 520 1:6 (1 cement: 6 coarse sand) 521 cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 522 20 mm cement plaster 523 white washing with lime to give an even shade : 524 new work (three or more coats) 525 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 526 new work (two or more coats) over and including water thinnable priming coat with cement primer 527 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade: 528 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 529 applying priming coat: 530 with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 531 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 532 painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 533 two or more coats on new work 534 painting with black anti corrosive bitumastic paint of approved brand and manufacture to give an even shade : 535 two or more coats on new work 536 water proofing 537 providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of w.c., kitchen and the like consisting of: 538 ist course of applying cement slurry @ 4.4 kg/sqm mixedwith water proofing compound conforming to is 2645 inrecommended proportions including rounding off junction of vertical and horizontal surface. 539 iind course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. 540 iiird course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. 541 ivth course of 400 micron thick pvc sheet. (overlaps at joints of pvc sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). 542 providing and laying in situ seven course water proofing treatment with app (atactic poly propylene) modified polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to is : 702, 3rd and 5th layers of roofing membrane app modified polymeric membrane 1.5 mm thick of 2.25 kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron hmhdpe film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron hmhdpe film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately). 543 non shedule items 544 providing and fixing aluminium handles, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 545 150 mm 546 providing and fixing aluminium door buffer of approved make, design and colour with necessary screws etc all complete as directed and specified by the engineer in charge : 547 providing and laying 1st quality ceramic glazed anti skid floortiles of size 300x300 mm (thickness to be specified by the manufacturer) conforming to is:15622 in all colours, shades, sizes as approved over 20 mm thick bed of cement mortar 1: 4 (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc complete in all respects as per specifications/drawings and to the entire satisfaction to the architect. 548 earth work 549 earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 550 all kinds of soil. 551 excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 552 all kinds of soil 553 pipes, cables etc, not exceeding 80 mm dia. 554 pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 555 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 556 roofing 557 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 558 110 mm diameter 559 providing and fixing on wall face unplasticised pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 560 coupler 561 110 mm 562 bend 87.5° 563 110 mm bend 564 shoe (plain) 565 110 mm shoe 566 providing and fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with m.s. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 567 110 mm 568 providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 569 sanitary installations 570 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 571 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 572 providing and fixing white vitreous china pedestal type water closet (european type) with seat and lid, 10 litre low level white vitreous china flushing cistern & c.p. flush bend with fittings & c.i. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : 573 w.c. pan with isi marked black solid plastic seat and lid 574 providing and fixing wash basin with c.i. brackets, 15 mm c.p. brass pillar taps, 32 mm c.p. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 575 white vitreous china flat back wash basin size 550x 400 mm with single 15 mm c.p. brass pillar tap 576 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is: 13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 577 kitchen sink with drain board 578 510x1040 mm bowl depth 250 mm 579 extra for using coloured pedestal type w.c pan (european type) with low level cistern of same colour instead of white vitreous china w.c pan and cistern. 580 providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with c.p. brass screws and washers complete. 581 providing and fixing toilet paper holder : 582 vitreous china 583 providing and fixing soil, waste and vent pipes : 584 100 mm dia. 585 centrifugally cast (spun) iron socket & spigot (s&s) pipe as per is: 3989 586 75mm diameter 587 centrifugally cast (spun) iron socketed pipe as per is: 3989 588 providing and fixing m.s. holder bat clamps of approved design to sand cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : 589 for 100 mm dia. pipe 590 for 75 mm dia. pipe 591 providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 592 100 mm 593 sand cast iron s&s as per is 3989 594 75 mm 595 sand cast iron s&s as per is 3989 596 providing and fixing plain bend of required degree. 597 100 mm 598 sand cast iron s&s as per is : 3989 599 75 mm 600 sand cast iron s&s as per is 3989 601 providing and fixing heel rest sanitary bend 602 100 mmdia 603 sand cast iron s&s as per is 3989 604 75 mm dia 605 sand cast iron s&s as per is 3989 606 providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3mm thick,bolts and nuts complete. 607 100x100x100mm 608 sand cast iron s&s as per is 3989 609 75x75x75mm 610 sand cast iron s&s as per is 3989 611 providing and fixing single equal plain junction of required degree 612 100x100x100mm 613 sand cast iron s&s as per is 3989 614 75x75x75mm 615 sand cast iron s&s as per is 3989 616 providing and fixing door piece, insertion rubber washer 3mm thick, bolts & nuts complete : 617 100 mm 618 sand cast iron s&s as per is 3989 619 75 mm 620 sand cast iron s&s as per is 3989 621 providing and fixing terminal guard : 622 100 mm 623 sand cast iron s&s as per is 3989 624 75 mm 625 sand cast iron s&s as per is 3989 626 providing and fixing collar : 627 100 mm 628 sand cast iron s&s as per is 3989 629 75 mm 630 sand cast iron s&s as per is 3989 631 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : 632 100 mm 633 75 mm 634 providing and fixing m.s. stays and clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter : 635 100 mm 636 75 mm 637 providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 638 100 mm inlet and 100 mm outlet 639 sand cast iron s&s as per is: 1729 640 cutting chases in brick masonry walls for following diameter sand cast iron/ centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : 641 100 mm dia 642 painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work : 643 75 mm diameter pipe 644 providing and fixing ptmt waste coupling for wash basin and sink, of approved quality and colour. 645 waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms 646 providing and fixing ptmt bottle trap for wash basin and sink. 647 bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms 648 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 649 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour. 650 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 651 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is: 13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 652 kitchen sink with drain board 653 510x1040 mm bowl depth 250 mm 654 providing and fixing 8mm dia c.p / s.s jet with flexible tube upto1 metre long with s.s triangular plate to eureopean type w.c of quality and make as approved by engineer in charge. 655 providing and fixing g.i. pipes complete with g.i. fittings including trenching & refilling. 656 external work 657 32mmdia nominal bore 658 40mmdia nominal bore 659 water supply 660 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 661 internal work exposed on wall 662 20 mm nominal outer dia pipes 663 25 mm nominal outer dia pipes 664 32 mm nominal outer dia pipes 665 40 mm nominal outer dia pipes 666 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 667 concealed work, including cutting chases and making good the walls etc. 668 15 mm nominal outer dia pipes 669 20 mm nominal outer dia pipes 670 25 mm nominal outer dia pipes 671 32 mm nominal outer dia pipes 672 making connection of g.i. distribution branch with g.i. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 673 25 to 40 mm nominal bore 674 providing and fixing brass stop cock of approved quality : 675 15 mm nominal bore 676 20 mm nominal bore 677 providing and fixing gun metal gate valve with c.i. wheel of approved quality (screwed end) : 678 25mm nominal bore 679 32mm nominal bore 680 40mm nominal bore 681 providing and fixing ball valve (brass) of approved quality, high or low pressure, with plastic floats complete : 682 25 mm nominal bore 683 providing and fixing brass ferrule with c.i. mouth cover including boring and tapping the main : 684 25 mm nominal bore 685 providing and fixing uplasticised pvc connection pipe with brass unions : 686 45 cm length 687 15 mm nominal bore 688 providing and fixing c.p. brass shower rose with 15 or 20 mm inlet : 689 100 mm diameter 690 providing and placing on terrace (at all floor levels) polyethylene water storage tank, is : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 691 rectangular tank 692 providing and fixing c.p. brass bib cock of approved quality conforming to is:8931 : 693 15 mm nominal bore 694 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 695 15 mm nominal bore 696 providing and fixing c.p. brass stop cock (concealed) of standard design and of approved make conforming to is:8931. 697 15 mm nominal bore. 698 providing and fixing c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 699 15 mm nominal bore 700 providing and fixing ptmt grating of approved quality and colour. 701 circular type. 702 100 mm nominal dia. 703 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 704 sewarage & drainage 705 providing, laying and jointing glazed stoneware pipes class sp 1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 706 100 mm diameter 707 150 mm diameter 708 providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all round s.w. pipes including bed concrete as per standard design : 709 100 mm diameter s.w. pipe 710 150 mm diameter s.w. pipe 711 providing and fixing square mouth s.w. gully trap class sp 1 complete with c.i. grating brick masonry chamber with water tight c.i. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70kg as per standard design: 712 180 x 150 mm size p type 713 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 714 constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with r.c.c. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : 715 inside size 90x80 cm and 45 cm deep including c.i. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : 716 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 717 extra for depth for manholes : 718 size 90x80 cm 719 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 720 providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per is : 10910, on 12 mm dia steel bar conforming to is: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 721 making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 722 for pipes 100 to 250 mm diameter 723 providing, laying and jointing non pressure np2 class (light duty)rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 724 150 mm dia rcc pipe 725 250 mm dia rcc pipe 726 non shedule items 727 providing and fixing concealed single leverbath & overhead shower mixer of hindware make and model no.(f360019cp) respectively or equivalent approved make as approved byengineer in charge. 728 providing & fixing sink mixer with swinging casted spout (wall mounted jaquar model con 309 kn)/approved equal with 450mm long copper pipes & brass nuts. 729 providing and fixing c.p. brass grab bar(600mm long) fixed with c.p. brass screwsincluding all fittings complete.jaquar model no. ahs 1507/approve equal. 730 subhead i wiring 731 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. 732 group c 733 wiring for light/ power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 734 wiring for light/ power plug with 4x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 nos. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 735 supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 736 4 module (125 mmx75 mm) 737 supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 738 15/16 a switch 739 3 pin 5/6 a socket outlet 740 telephone socket outlet 741 tv antenna socket outlet 742 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 743 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire 744 2 x 6 sq. mm + 1 x 6 sq. mm earth wire 745 2 x 10 sq. mm + 1 x 6 sq. mm earth wire 746 4 x 4 sq. mm + 2 x 4 sq. mm earth wire 747 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface/ recessed steel/ pvc conduit as required. 748 supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 749 25 mm 750 supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 751 1 or 2 module (75 mmx75 mm) 752 supplying and drawing following pair 0.5 mm dia frls pvc insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ pvc conduit as required. 753 2 pair 754 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 755 20 mm 756 25 mm 757 providing and fixing in position 2mm thick m.s. telephone junction box of size suitable for fixing of following krone tag block with key lock arrangement. also provide clamps for fixing tag blocks. 758 10 pair telephone tag blockwith box 759 supplying, laying of 10 pair unarmoured pvc insulated copper conductor (atc) telephone cable in ground/existing pipes/on wall and making connection with telephone main junction box (mdf) including supports and all accessories as required 760 10 pair cable unarmoured 761 subhead ii supply & installation of fittings 762 supplying of following box type fl. fitting made out of crca sheet finished in antirust treated non yellowing super white stove enamelled paint duly wired with copper wound heavy duty choke starter holder, starter but without lamp complete etc. as reqd. 763 mounting rail for tled lamps 1600 lumens (tmc 501 p 1xt led with essential led 18w tube) 764 sereno 42 watt 2950 lumens philips sp824 p led 30s 5000 gr oa 765 supplying of wall mounted suitable for 1300 lumens complete with ballast & accessories such as wire guard etc. complete as required. 766 15w astra surface & wall mounted 1300 lumens ( philips bn150w led13s 6500 pse od gr ) 767 supplying of wall bracket light fittings suitable for 11 / 13 w cfl lamp. the fitting shall be made up of m.s. powder coated provided with integral ballast, frosted glass and 1 no. 11 / 13 wlamp duly wired upto the connector block complete as required. (decon cat. no.05aam) 768 supplying of ceiling light fittings suitable for 1 x 15/20 w led lamp. the fitting shall be made up of m.s. powder coated provided with electronic ballast, 1 no. 15/20 w led lamp duly wired upto the connector block etc. complete as required. 769 cirrus mini pro 15 / 20 watt & 1100 /1600 lumens (philips sm200c led11s 6500 psu od wh) 770 supplying of bulk head fittings suitable for 10 w led lamp complete with ballast & accessories such as glass, wire guard, 60 w cfl lamp etc. complete as required. 771 endural led bulkhead, 10 w, 600 lumen such as (philips wt202w led6s cw psu s2 pc) 772 supplying of exhaustfan, all complete with mounting ring frame i/c bracket,but without regulator with shutters in the following sizes. (g.e. alsthom, khaitan & havells company) 773 300 mm 4 pole 774 supplying of 1400 mm sweep a.c. electric ceiling fans, capacitor type with double ball bearing complete with 300 mm down rod, canopies, shackles, blades, but without regulator suitable for operation on 230 / 240 volts, 50 hz, single phase, a.c. supply. (crompton, khaitan & havells company) 775 supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 776 installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 777 installation, testing and commissioning of pre wired, light fixture / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 778 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 779 upto 450 mm sweep 780 extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. 781 installation, testing and commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two gls/cfl/ led lamps per fitting, complete with all accessories including connections etc. as required. 782 supplying and fixing call bell/ buzzer suitable for single phase, 230 v, complete as required. 783 subhead iii distribution board 784 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/ isolator) 785 6 way (4 + 18), double door 786 supplying and fixing following rating, four pole, 415 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 787 100 a 788 supplying and fixing following rating, four pole, (three phase and neutral), 415 v, residual current circuit breaker (rccb), having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. 789 63 a 790 supplying and fixing following rating, double pole, 240 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 791 40 amps 792 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 793 12 way , double door 794 16 way , double door 795 supplying and fixing following rating, double pole, (single phase and neutral), 240 v, residual current circuit breaker (rccb), having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. 796 25 a 797 40 a 798 supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 799 single pole 800 subhead iv earthing 801 earthing with g.i. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 802 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re filling as required. 803 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 804 subhead v street lighting on building 805 supplying, installing, testing and commissioning of 2 x 36w general purpose flourescent street light fittings with sheet aluminium housing and uv stabilized acrylic cover complete with chokes, starter holders, condensers, reflector cover etc. as reqd. (philips cat no. trc 33 / 236 hpf) (to be fixed directly on wall of building) 806 supplying and fixing of 32 mm dia x 2.00 meter long g.i. pipe (medium class) bracket for mounting of fluorescent / hpmv / hpsv street light fitting on pole including bending the pipe to the required shape, 2 nos. 40 mm x 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. 807 supply of following sizes of frls 1.1 kv stranded compact circular aluminium conductor screened with extruded semi conducting compound, xlpe insulated,al round wire armoured & overall pvc sheathed cableconforming to is to is 7098 (part i) with latest amendments 808 2 x 4 sq.mm 809 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. 810 upto 35 sq. mm 811 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc/ hume/ metal pipe as required. 812 upto 35 sq. mm 813 laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required. 814 upto 35 sq. mm (clamped with 1mm thick saddle) 815 supplying and making end termination with brass compression gland and aluminium lugs for following size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required. 816 2 x 6 sq. mm (19mm) 817 supply & fixing of 150x200 mm 60mm deep ms junction box recess or surface on wall with 3mm bakalite cover15 overlapping 15 all sides of junction box & housing 4way 32amps bakelie connector to terminate incoming & outgoing armoured cable & & wiring the light fixture with 3x1.5 sq mm pvc insulated coppwer wire including interconnection ets as reqired .( cost of termination of armoured cable with gland is not to be included as the same is payable under separate item no 5.07 of this subhead) 818 providing, laying and fixing following dia rcc pipe np2 class (light duty) in ground complete with rcc collars, jointing withcement mortar1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required. 819 100 mm dia 820 subhead vi lightning conductor 821 providing and fixing of lightning conductor finial, made of 25mm dia 300 mm long, g.i. tube, having single prong at top, with85 mm dia 6 mm thick g.i. base plate including holes etc.complete as required. 822 jointing copper / g.i. tape (with another copper/ g i tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 823 fixing of copper/ g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for horizontal run) 824 fixing of copper/ g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for vertical run) 825 providing and fixing testing joint, made of 20 mm x 3 mm thickg.i. strip, 125 mm long, with 4 nos. of g.i. bolts, nuts, chucknuts and spring washers etc. complete as required. 826 laying copper/ g.i. tape 32 mm x 6 mm from earth electrodedirectly in ground as required 827 earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 828 all kinds of soil 829 excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 830 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 831 supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 832 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone iii) : 10 graded stone aggregate 40 mm nominal size) 833 providing and laying in position machine batched and machine mixed design mix m 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per is: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of engineer in charge.“(note : cement content considered in this item is @ 330 kg/cum.“excess/ less cement used as per design mix is payable/recoverable separately). 834 upto plinth level 835 (i) r.c.c. work in footing 836 (ii) r.c.c. work in beam 837 (iii) r.c.c. work in columns 838 above plinth to floor v lvl 839 same as above but r.c.c. work abive plinth lvl. 840 (i) r.c.c. work in lintel 841 (ii) r.c.c. work in beam 842 (iii) r.c.c. work in columns 843 (iv) r.c.c. work in slab 844 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. thermo mechanically treated bars of grade fe 500d or more. 845 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. thermo mechanically treated bars of grade fe 500 d or more. 846 add for plaster drip course/ groove in plastered surface or moulding tor.c.c. projections. 847 centering and shuttering including strutting, propping etc. and removal of form for all heights : 848 foundations, footings, bases of columns, etc. for mass concrete. 849 suspended floors, roofs, landings, balconies and access platform. 850 lintels, beams, plinth beams, girders, bressumers and cantilevers. 851 columns,pillars, piers, abutments, posts and struts. 852 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in foundation and plinth in: 853 cement mortar 1:6 (1 cement : 6 coarse sand) 854 providing and laying damp proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone iii): 4 graded stone aggregate 12.5mm nominal size) 855 providing & applying a coat of residual petroleum bitumen of grade of vg 10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 856 providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick aac blocks in super structure above plinth level up to floor v level with rcc band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of engineer in charge. (the payment of rcc band and reinforcement shall be made for seperately). 857 half brick masonry with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in foundations and plinth in : cement mortar 1:4 (1 cement : 4 coarse sand) 858 extra for providing and placing in position 2 nos 6mm dia. m.s. bars at every third course of half brick masonry. 859 providing and laying in situ seven course water proofing treatment with app (atactic poly propylene) modified polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to is : 702, 3rd and 5th layers of roofing membrane app modified polymeric membrane 1.5 mm thick of 2.25 kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron hmhdpe film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron hmhdpe film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately). 860 providing and laying brick tiles over mumty roofs, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat: 12.19.1 with common burnt clay f.p.s. (non modular) brick tilesof class designation 10 861 providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to is : 14616 and tads 15:2001 (part b), including isi marked m.s. pressed butt hinges bright finished of required size with necessary screws, all complete as per directions of engineerin charge and panelling with panels of : 12 mm thick one side pre laminated particle board (decorative lamination on one side and other sides balancing lamination) grade 1, medium density flat pressed, three layer particle board fpt i or graded wood particle board fpt 1 conforming to is : 3087 bonded with bwp type synthetic resin adhesive as per is : 848 and pre laminated conforming to is : 12823, grade 1, type ii marked : 862 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 863 providing and fixing t iron frames for doors, windows and ventilators of mild steel tee sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer 864 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size 865 providing and fixing factory made upvc white colour fixed glazed windows/ ventilators comprising of upvc multi chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to upvc profile), ,upvc extruded glazing beads of appropriate dimension, epdm gasket, g.i fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of engineer in charge. (single / double glass panes and silicon sealant shall be paid separately). variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 866 fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. 867 providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes. 868 providing and fixing wire gauge shutters using galvanized m.s. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 869 30 mm thick shutters with isi marked m.s. pressed butt hinges bright finished of required size second class teak wood 870 providing and fixing factory made upvc white colour sliding glazed window upto 1.50 m in height dimension comprising of upvc multi chambered frame with in built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to upvc profile), appropriate dimension of upvc extruded glazing beads and upvc extruded interlocks, epdm gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), g.i fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of engineer in charge. (single / double glass panes, wire mesh and silicon sealent shall be paid separately). variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 871 three track three panels sliding window with fly proof s.s wire mesh (two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (area of window above 1.75 sqm). 872 15 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement: 6 coarse sand) 873 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) 874 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 875 providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. size of tile 600x600 mm. 876 providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. size of tile 600x600 mm 877 providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. area of slab upto 0.50 sqm 878 providing and laying ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 879 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 880 providing edge moulding to 18mm thick marble stone counters, vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer in charge. 881 granite work 882 extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete. 883 extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/granite/stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 884 steel painting: 885 (a) with ready mixed red oxide zink chromate primer of approved brand and manufacture on steel galvanised iron/steel works. 886 (b) painting withsynthetic enamel paint of approvedbrandand manufactureto give an even shade:two or more coats on new work. 887 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : new work (two or more coats) over and including water thinnable priming coat with cement primer. 888 finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade. new work (two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). 889 providing and fixing isi marked oxidised m.s. single acting spring hingeswith necessary screws etc. complete : 890 150 mm 891 providing and fixing oxidised m.s. hasp and staple (safety type)conforming to is : 363 with necessary screws etc. complete : 892 90 mm 893 providing and fixing special quality bright finished brass cupboard orward robe locks with four levers of approved quality including necessaryscrews etc. complete. 894 75 mm 895 providing and fixing wooden moulded corner beading of triangular shape to the junction of panelling etc. with iron screws, plugs and priming coat on unexposed surface etc. complete 2nd class teak wood. 896 50x50 mm (base and height) 897 providing and fixing aluminium sliding door bolts, isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 898 250x16 mm 899 providing and fixing aluminium tower bolts, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 900 200x10 mm 901 providing and fixing aluminium handles, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 902 125 mm 903 providing and fixing aluminium hanging floor door stopper isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. twin rubber stopper 904 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 905 25 mm thick (for cupboard) including isi marked nickel plated bright finished m.s. piano hinges with necessary screws 906 providing and fixing pre laminated flat pressed 3 layer (medium density) particle board or graded wood particle board is : 3087 marked, with one side decorative and other side balancing lamination grade i, type ii exterior grade is : 12823 marked, in shelves with screws and fittings wherever required, edges to be painted with polyurethane primer (fittings to be paid separately). 907 float glass panes 4.0 mm thick glass panes (weight not less than 10 kg/sqm). 908 providing and fixing white vitreous china pedestal type water closet (european type w.c. pan) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. 909 w.c. pan with isi marked white solid plastic seat and lid 910 providingandfixing p.v.c. waste pipe forsink or wash basin including pvc waste fittings complete. 911 flexible pipe 912 40 mm dia(for sink and urinal) 913 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is: 13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 914 kitchen sink with drain board 915 510x1040 mm bowl depth 250 mm 916 providing and fixing wash basin with c.i.brackets, 15 mm c.p. brass pillar taps, 32 mm c.p. brass waste of standard pattern,includingpainting of fittings and brackets, cutting and making good the walls wherever required 917 white vitreous china wash basin size 550x400 mm with single 15 mm c.p. brass pillar tap 918 providing and fixing cp brass 32mm size bottle trap of bapproved quality & make and as per the direction of engineerin charge. 919 providing & fixing c.p. brass health faucet for ablution with 1 meter long pvc tube, hand shower, couplings, wall hook and other accessories. 920 providing & fixing cp brass overhead shower with shower arm, hand shower 95mm dia single lever concealed deusch mixer with provision for connection to overhead shower and easy flex tube with accessories complete i allrespect 921 providing & fixing c.p. brass waste coupling for pvc waste pipe. 922 providing & fixing 600 x 450 mm bevelled edge mirror of superiorglass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with c.p. brass screws and washers complete. 923 providing & fixing toilet paper holder. 924 viterous china 925 providing and fixing of c. p. brass towel rail 600 x 20 mm size complete with c.p. brass brackets 926 providing and fixing of c. p. brass towel ring complete with c.p. brass brackets 927 providing and fixing cp brasssoap dish 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket and all fittings of the same material of approved quality and colour. 928 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor soil, waste, and vent, type b as per is : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors),reducers, wc connectors, couplers, expansion joints / bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor & basement ceiling / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382. 929 the pipes will be supported with threaded g i rods & u clamps with nuts, washers etc on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg in charge at site. 930 110 mm dia (wall thickness 3.2 to 3.8 mm) 931 75 mm dia (wall thickness 3.2 to 3.8 mm) 932 providing, fixing, jointing and testing in position isi marked (is:4985) upvc pipes of min 6 kg/ sqcm rating with fitting for waste pipe from fixtures to floor trap including reduces, enlarger, socket, couplers, bends, tees etc including fixing at wall/ ceiling level supported by clamp & hangers etc. cutting holes in wall/ floors/ slabs and making good the same with cement concrete 1:2:4 complete as required. 933 32 mm dia. 934 providing & fixing upvc floor trap of self cleansing designwith stainless steel grating complete in all respects. 935 multi floor trap (5 ht) with height raiser and branch saddle strip of 50/75 mm outlet 936 plain floor trap (4 ht) with 50 / 75 outlet and with height raiser 937 p trap type floor trap 110 x 75 mm 938 extra for providing & fixing 125 mm dia c.p. grating in place of c.i. grating over floor traps. 939 providing, fixing, jointing and testing in position of isi marked uv stabilized upvc pipesfor rain water disposal, type b as peris : 13592 suitable for rubber ring joints, including all neccessary specials and fittings (confirming to is:14735) i.e. bends, tees, junctions (with or without doors), reducers, couplers, expansion joints / bellows, cowels, clamps, rubber rings, ms gratings over pipes of bell mouth construction with epoxy painting etc. fixing at wall/ ceiling/ floor level supported by clamp & hangers etc. in concealed / inside duct / under floor / external work etc. including chase cutting as required, excavation and back filling in all kind of soils, suspended from floor under false ceiling or embedding the pipes laid under floors / building in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of shuttering for proper completion of the work, breaking and making good the walls and floors etc. after pipes have been duly laid and tested. the rubber ring shall confirm to is:5382. 940 the pipes will be supported with threaded g i rods & clamps on 50x50x5 mm slotted angle. the cost will include all support arrangements. the work includes commissioning of all pipes lines as per drawings and specifications and as directed by engg in charge at site. 941 110 mm dia 942 making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over p.v.c. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 943 providing&fixing15 mm nominal bore45 cm long unplasticised pvc connection pipewith brass unions. 944 45 cm length 945 15 mm nominal bore 946 providing and fixing c.p brass bib cock of approved qualityconforming to is standards is: 8931. 947 15 mm nominal bore 948 providing and fixing c.p brass long nose bib cock of approved qualityconforming to is standardsandweighing notlessthan 810 gms. 949 15 mm nominal bore 950 providing & fixing 15 mm nominal bore c.p brass angle valve for basin mixer and geyser points of approved quality conformingto is8931. 951 15 mm nominal bore 952 constructing brick masonry chamber 300 x 300x500mm, insidewithf.p.s. brick work in cement mortar 1: 4 (1 cement : 4 coarse sand) for stopcock, withc. i. surface box 100 x 100 x 75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4mix (1cement : 2 coarse sand:4 grade stone aggregate 20mm nominal size); necessary excavation, foundationconcrete 1:5:10 (1 cement :5 fine sand: 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar1 : 3 (1 cement : 3 coarse sand )12mmthick finished with a floatingcoatof neat cementcomplete as per standard design 953 with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 954 providing & fixing g.i. unoun in g.i. pipe including cutting and threading the pipe & making long screws etc. complete. 955 15mm dia nominal bore 956 20mm dia nominal bore 957 25mm dia nominal bore 958 32mm dia nominal bore 959 40mm dia nominal bore 960 cutting holes up to 30 x 30 cm in walls including making good the same: 961 with common burnt clay f.p.s. (non modular) bricks 962 providing, fixing chlorinated polyvinyl chloride (cpvc) pipescts sdr 11, class 1 cpvc pipes (pressure rating 28 kg/cm2 at 23oc and 7 kg/cm2 at 82oc) confirming to is : 15778 2007, astm d 2846, havingthermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 963 internal work exposed on wall 964 20mm nominal outer dia pipes 965 25mm nominal outer dia pipes 966 32mm nominal outer dia pipes 967 40mm nominal outer dia pipes 968 providing, fixing chlorinated polyvinyl chloride (cpvc) pipescts sdr 11, class 1 cpvc pipes (pressure rating 28 kg/cm2 at 23oc and 7 kg/cm2 at 82oc) confirming to is : 15778 2007, astm d 2846, havingthermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 969 concealed work including cutting chase and making good the wall etc. 970 15mm nominal outer dia pipes 971 20mm nominal outer dia pipes 972 providing and placing on terrace (at all floor levels) polyethylene water storage tank, is : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 973 circular tank 974 providing & fixing of hand lever operated forged brass body full way ball valve type isolating valve having forged brass hard chrome plated mirror finish ball, steel handle with pvc grip, teflon seat, screwed ends tested to a pressure of 15 kg/sqcm complete. 975 15 mm nominal bore 976 20 mm nominal bore 977 a) 25 mm dia 978 40 mm nominal bore 979 providing & fixing brass ball float valvewith bronzefloats of approved quality complete. 980 20 mm nominal dia 981 providing & fixing of medium class g.i.spout up to 300 mm. length including cutting and making good the walls and floors etc. as required. 982 a) 25 mm dia 983 sub head (i) : internal wiring 984 point wiring in pvc conduit, with modular type switch : 985 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. 986 group c 987 wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed pvc conduit, and earthing the point with 1.5 sq. mm frls pvc insulated copper conductor single core cable etc. as required. 988 group c 989 twin control point wiring in pvc conduit, with modular type switch : 990 wiring for twin control light point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, 2 way modular switch, modular switch, suitable m.s. box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. 991 power plug wiring in pvc conduit (2 x 4 sq.mm.) : 992 wiring for light/ power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 993 circuit / sub main wiring in pvc conduit : 994 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 995 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire. 996 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire. 997 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire 998 2 x 10 sq.mm. + 1 x 6 sq.mm. earth wire 999 4 x 10 sq.mm. + 2 x 6 sq.mm. earth wire 1000 s/f light plug point modular type accessories : 1001 supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 a modular socket outlet and 5/6 a modular switch, connections etc. as required 1002 s/f power plug point modular type accessories : 1003 supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 a modular socket outlet and 15/16 a modular switch, connections etc. as required. 1004 supplying and fixing 20 amps, 240 volts, spn, industrial type socket outlet, with 2 poles and earth metal enclosedplug top alongwith 20amps. c curve, sp mcb in sheet steel enclosure, on surface or in recess, with chainedmetal cover for the socket outlet, and complete with connections, testingandcommissioning etc. as required. 1005 s/f modular type electronic fan regulator : 1006 supply and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 1007 s/f modular type blanking plate : 1008 supply and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 1009 sub head (ii) : distribution boards & mcbs 1010 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 1011 8 way , double door 1012 supplying and fixing followingway, horizontal type tp&n, sheet steelmcb distribution board,415 v on surface /recess,completewithtinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (but without mcb / rccb / isolators). 1013 8 way (4 + 24), double door 1014 supplying and fixing following rating, double pole, (single phase and neutral), 240 volts,residual current circuit breaker (rccb), having a sensitivity current upto 30 ma in the existingmcbdbcomplete with connections, testing andcommissioning etc. as required. 1015 63 amps. 1016 supplying and fixing 5 amps. to 32 amps. rating, 240 volts `c series,miniature circuit breaker (mcb)suitable for inductive load offollowingpolesin the existingmcbdbcomplete with connections, testing andcommissioning etc. as required. 1017 single pole 1018 supplying & fixing single pole, blanking plate in the existing mcbdbcomplete etc. as required. 1019 supplying and fixing following rating, single/ double/ three pole, 230/ 415 volts, mcb c curve in the existing mcb db complete with connections, testing and commissioning etc. as required. 1020 63 amps fp mcb 1021 40 amps dp mcb 1022 sub head (iii) : telephone, television & data system 1023 s/f modular boxes, base & cover plate : 1024 supplying and fixing following size / modules, gi box along with modular base & cover plate for modular switches inrecessetc as required 1025 1 or 2 module (75 mm x 75 mm) 1026 s/f modular type switch / socket : 1027 supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc as required 1028 telephone socket outlet 1029 tv antenna socket outlet 1030 supply and fixing offollowingsizes of medium class pvc conduit along with accessories in surface/recess including cuttingthe wall and making good the same in case of recessed conduit as required : 1031 20 mm. 1032 25 mm. 1033 supply and drawing followingpair, 0.5 sq.mm. frls pvc insulated annealed copper conductor, unarmoured telephone cable in the existing surface / recessed steel/ pvc conduit as required. 1034 2 pair 1035 supply and drawing co axial tv cable rg 6 grade, 0.7 mm. solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface / recessed steel/ pvc conduit as required. 1036 sub head (iv) : miscellaneous 1037 providing and fixing m.v. dangernotice plate of 200mmx150mm made of mild steel, atleast 2mm thick and vitreous enamelled white on both sides and with inscription singleredcolouronfrlsontsideas required. 1038 supplying and fixing call bell/buzzer suitablefor single phase, 230 volts, complete as required. 1039 providing and fixing circular/ hexagonal cast iron or m.s. sheet box forceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5mm thick m.s. sheet with its top surface hacked for proper bonding,top lid shall be screwed into the cast iron/ m.s. sheet box by means of3.3 mm dia round headed screws, one lock at the corners. clamp shallbe made of 12 mm dia m.s. bar bent to shape as per standard drawing. 1040 sub head(v): internal lighting fixtures & fans 1041 supply of lighting fixtures 1042 supply of 15w surface mounted led with all accessories as per standard item..(such as panasonic adl04r156 or equivalent). 1043 supply of 15w wall bracket led bulb with all accessories as per standard item..(such as panasonic pbum01157 or equivalent). 1044 supply of 20w surface mounted led with all accessories as per standard item..(such as panasonic adl04r206 or equivalent). 1045 supply of 20w surface mounted led tube with all accessories as per standard item..(such as panasonic pbtm01207 or equivalent). 1046 supply of ceiling & exhaust fans 1047 supply of ac230/250 volts, 50 hzceiling fanwith standarddownrod, blades, 2 nos. caps & regulator etc. isi with 5 star marked & energy efficient complete as required. (such as havells velocity/velocity hs or equivalent). 1048 1200 mm sweep 1049 supply of ac230/250 volts, 50 hz exhaust fansincluding providingnuts, bolts, mounting frlsame and other accessories etc. complete as required (such as ventil air dx white or equivalent). 1050 300 mm sweep 900 rpm 1051 erectionoflightingfixturesandfans 1052 installation, testing and commissioning of pre wired, flourescent fitting / compact fluorescent fitting of all types, complete with all accessories and tubes etc. directly on ceiling / wall, including connection with 1.5 sq. mm. frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 1053 installation, testing and commissioning of ceiling fan including wiring the down rod of standard length (upto 30 cm.) with 1.5 sq. mm. frls pvc insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 1054 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required 1055 upto 450 mm sweep 1056 sub head(vi): lightning conductor 1057 providing and fixing of lightning conductor finial, made of 25mm dia 300 mm long, g.i. tube, having single prong at top, with85 mm dia 6 mm thick g.i. base plate including holes etc.complete as required. 1058 jointing copper / g.i. tape (with another copper/ g i tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 1059 fixing of copper/ g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for horizontal run) 1060 fixing of copper/ g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for vertical run) 1061 providing and fixing testing joint, made of 20 mm x 3 mm thickg.i. strip, 125 mm long, with 4 nos. of g.i. bolts, nuts, chucknuts and spring washers etc. complete as required. 1062 laying copper/ g.i. tape 32 mm x 6 mm from earth electrodedirectly in ground as required 1063 earth work 1064 earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1065 all kinds of soil 1066 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 1067 excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 1068 concrete work 1069 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 1070 1:5:10 (1 cement : 5 coarse sand (zone iii) : 10 graded stone aggregate 40 mm nominal size) 1071 providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : 1072 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). 1073 providing and laying damp proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone iii): 4 graded stone aggregate 12.5mm nominal size) 1074 providing & applying a coat of residual petroleum bitumen of grade of vg 10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 1075 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 1076 reinforcedcementconcrete 1077 centering and shuttering including strutting, propping etc. and removal of form for all heights: 1078 foundations, footings, bases of columns, etc. for mass concrete 1079 columns, pillars, piers, abutments, posts and struts 1080 small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like 1081 edges of slabs and breaks in floors and walls 1082 under 20 cms wide 1083 suspended floors, roofs, landings, balconies and access platform. 1084 lintels, beams, plinth beams, girders, bressumers and cantilevers. 1085 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 1086 thermo mechanically treated bars of grade fe 500d or more. 1087 add for plaster drip course/ groove in plastered surface or moulding to r.c.c. projections. 1088 providing and laying in position machine batched and machine mixed design mix m 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per is: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of engineer in charge.“(note : cement content considered in this item is @ 330 kg/cum.“excess/ less cement used as per design mix is payable/recoverable separately). 1089 all works upto plinth level 1090 all works above plinth level upto floor v level 1091 brick work 1092 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in foundation and plinth in: 1093 cement mortar 1:6 (1 cement : 6 coarse sand) 1094 providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick aac blocks in super structure above plinth level up to floor v level with rcc band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of engineer in charge. (the payment of rcc band and reinforcement shall be made for seperately). 1095 half brick masonry with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level. 1096 cement mortar 1:4 (1 cement :4 coarse sand) 1097 extra for providing and placing in position 2 nos 6mm dia. m.s. bars at every third course of half brick masonry. 1098 brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand). 1099 marble work 1100 providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 1101 granite of any colour and shade 1102 area of slab over 0.50 sqm 1103 providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer in charge. 1104 granite work 1105 extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. 1106 extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 1107 wood work & pvc work 1108 providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). 1109 second class teak wood 1110 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 1111 25 mm thick (for cupboard) including isi marked nickel plated bright finished m.s. piano hinges is : 3818 marked with necessary screws 1112 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1113 35 mm thick including isi marked stainless steel butt hinges with necessary screws 1114 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 1115 providing and fixing wire gauge shutters using galvanized m.s. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 1116 35 mm thick shutters 1117 kiln seasoned and chemically treated hollock wood 1118 providing and fixing aluminium sliding door bolts, isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 1119 250x16 mm 1120 providing and fixing aluminium tower bolts, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 1121 200x10 mm 1122 providing and fixing aluminium handles, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 1123 125 mm 1124 providing and fixing aluminium hanging floor door stopper, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. 1125 twin rubber stopper 1126 providing & fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to is : 2046 type s, including cost of adhesive of approved quality. 1127 1.5 mm thick 1128 providing and fixing cup board shutters with 25 mm thick veneered particle board is : 3097 marked, exterior grade (grade i), of approved make, including iind class teak wood lipping of 25 mm wide x 12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of engineer in charge. 1129 with decorative veneering on one side and commercial veneering on other side 1130 providing and fixing factory made upvc white colour sliding glazed window upto 1.50 m in height dimension comprising of upvc multi chambered frame with in built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to upvc profile), appropriate dimension of upvc extruded glazing beads and upvc extruded interlocks, epdm gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), g.i fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of engineer in charge. (single / double glass panes, wire mesh and silicon sealent shall be paid separately). variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 1131 three track three panels sliding window with fly proof s.s wire mesh (two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (area of window above 1.75 sqm). 1132 providing and fixing isi marked oxidised m.s. single acting spring hingeswith necessary screws etc. complete : 1133 150 mm 1134 providing and fixing oxidised m.s. hasp and staple (safety type)conforming to is : 363 with necessary screws etc. complete : 1135 90 mm 1136 providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 1137 75 mm 1138 providing and fixing wooden moulded corner beading of triangular shape to the junction of panelling etc. with iron screws, plugs and priming coat on unexposed surface etc. complete 2nd class teak wood. 1139 50x50 mm (base and height) 1140 float glass panes 1141 4.0 mm thick glass panes (weight not less than 10 kg/sqm). 1142 steel work 1143 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 1144 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1145 providing and fixing t iron frames for doors, windows and ventilators of mild steel tee sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 1146 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1147 providing and fixing circular/ hexagonal cast iron or m.s. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick m.s. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ m.s. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. clamp shall be made of 12 mm dia m.s. bar bent to shape as per standard drawing. 1148 providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 1149 4.0 mm thick glass panes 1150 flooring 1151 kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 1152 25 mm thick. 1153 providing and fixing glass strips in joints of terrazo/ cement concrete floors. 1154 40 mm wide and 4 mm thick 1155 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 1156 extra for pre finished nosing in treads of steps of kota stone/ sand stone slab. 1157 extra for kota stone/ sand stone in treads of steps and risers using single length up to 1.05 metre. 1158 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 1159 providing and laying ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 1160 providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 1161 size of tile 600x600 mm 1162 providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. 1163 size of tile 600x600 mm 1164 roofing 1165 providing and laying brick tiles over mumty roofs, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat. 1166 with common burnt clay f.p.s. (non modular) brick tilesof class designation 10 1167 making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over p.v.c. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 1168 finishing 1169 12 mm cement plaster of mix 1170 1:6 (1 cement: 6 coarse sand) 1171 15 mm cement plaster on rough side of single or half brick wall of mix: 1172 1:6 (1 cement: 6 coarse sand) 1173 white washing with lime to give an even shade : 1174 new work (three or more coats) 1175 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1176 new work (two or more coats) over and including water thinnable priming coat with cement primer 1177 finishing walls with premium acrylic smooth exterior paint withsilicone additives of required shade: 1178 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 1179 applying priming coat: 1180 with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 1181 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 1182 painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 1183 two or more coats on new work 1184 painting with black anti corrosive bitumastic paint of approved brand and manufacture to give an even shade : 1185 two or more coats on new work 1186 water proofing 1187 providing and laying in situ seven course water proofing treatment with app (atactic poly propylene) modified polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to is : 702, 3rd and 5th layers of roofing membrane app modified polymeric membrane 1.5 mm thick of 2.25 kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron hmhdpe film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron hmhdpe film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately). 1188 providing and laying brick tiles over mumty roofs, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat: 12.19.1 with common burnt clay f.p.s. (non modular) brick tilesof class designation 10 1189 earth work 1190 earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1191 all kinds of soil. 1192 excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 1193 all kinds of soil 1194 pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 1195 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 1196 roofing 1197 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 1198 110 mm diameter 1199 providing and fixing on wall face unplasticised pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 1200 coupler 1201 110 mm 1202 bend 87.5° 1203 110 mm bend 1204 shoe (plain) 1205 110 mm shoe 1206 providing and fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with m.s. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 1207 110 mm 1208 providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 1209 sanitary installations 1210 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1211 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 1212 providing and fixing wash basin with c.i. brackets, 15 mm c.p. brass pillar taps, 32 mm c.p. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 1213 white vitreous china flat back wash basin size 550x 400 mm with single 15 mm c.p. brass pillar tap 1214 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is: 13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 1215 kitchen sink with drain board 1216 510x1040 mm bowl depth 250 mm 1217 extra for using coloured pedestal type w.c pan (european type) with low level cistern of same colour instead of white vitreous china w.c pan and cistern. 1218 providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with c.p. brass screws and washers complete. 1219 providing and fixing toilet paper holder : 1220 vitreous china 1221 providing and fixing soil, waste and vent pipes : 1222 100 mm dia. 1223 centrifugally cast (spun) iron socket & spigot (s&s) pipe as per is: 3989 1224 75mm diameter 1225 centrifugally cast (spun) iron socketed pipe as per is: 3989 1226 providing and fixing m.s. holder bat clamps of approved design to sand cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : 1227 for 100 mm dia. pipe 1228 for 75 mm dia. pipe 1229 providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 1230 100 mm 1231 sand cast iron s&s as per is 3989 1232 75 mm 1233 sand cast iron s&s as per is 3989 1234 providing and fixing plain bend of required degree. 1235 100 mm 1236 sand cast iron s&s as per is : 3989 1237 75 mm 1238 sand cast iron s&s as per is 3989 1239 providing and fixing heel rest sanitary bend 1240 100 mmdia 1241 sand cast iron s&s as per is 3989 1242 75 mm dia 1243 sand cast iron s&s as per is 3989 1244 providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3mm thick,bolts and nuts complete. 1245 100x100x100mm 1246 sand cast iron s&s as per is 3989 1247 75x75x75mm 1248 sand cast iron s&s as per is 3989 1249 providing and fixing single equal plain junction of required degree 1250 100x100x100mm 1251 sand cast iron s&s as per is 3989 1252 75x75x75mm 1253 sand cast iron s&s as per is 3989 1254 providing and fixing door piece, insertion rubber washer 3mm thick, bolts & nuts complete : 1255 100 mm 1256 sand cast iron s&s as per is 3989 1257 75 mm 1258 sand cast iron s&s as per is 3989 1259 providing and fixing terminal guard : 1260 100 mm 1261 sand cast iron s&s as per is 3989 1262 75 mm 1263 sand cast iron s&s as per is 3989 1264 providing and fixing collar : 1265 100 mm 1266 sand cast iron s&s as per is 3989 1267 75 mm 1268 sand cast iron s&s as per is 3989 1269 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : 1270 100 mm 1271 75 mm 1272 providing and fixing m.s. stays and clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter : 1273 100 mm 1274 75 mm 1275 providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 1276 100 mm inlet and 100 mm outlet 1277 sand cast iron s&s as per is: 1729 1278 cutting chases in brick masonry walls for following diameter sand cast iron/ centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : 1279 100 mm dia 1280 painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work : 1281 100 mm diameter pipe 1282 75 mm diameter pipe 1283 providing and fixing ptmt waste coupling for wash basin and sink, of approved quality and colour. 1284 waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms 1285 providing and fixing ptmt bottle trap for wash basin and sink. 1286 bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms 1287 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 1288 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour. 1289 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 1290 providing and fixing g.i. pipes complete with g.i. fittings including trenching & refilling. 1291 external work 1292 32mmdia nominal bore 1293 water supply 1294 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 1295 internal work exposed on wall 1296 25 mm nominal outer dia pipes metre 1297 32 mm nominal outer dia pipes metre 1298 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 1299 concealed work, including cutting chases and making good the walls etc. 1300 15 mm nominal outer dia pipes 1301 20 mm nominal outer dia pipes 1302 making connection of g.i. distribution branch with g.i. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 1303 25 to 40 mm nominal bore 1304 providing and fixing brass stop cock of approved quality : 1305 15 mm nominal bore 1306 20 mm nominal bore 1307 providing and fixing gun metal gate valve with c.i. wheel of approved quality (screwed end) : 1308 25mm nominal bore 1309 32mm nominal bore 1310 40mm nominal bore 1311 providing and fixing ball valve (brass) of approved quality, high or low pressure, with plastic floats complete : 1312 25 mm nominal bore 1313 providing and fixing brass ferrule with c.i. mouth cover including boring and tapping the main : 1314 25 mm nominal bore 1315 providing and fixing uplasticised pvc connection pipe with brass unions : 1316 45 cm length 1317 15 mm nominal bore 1318 providing and fixing c.p. brass shower rose with 15 or 20 mm inlet : 1319 100 mm diameter 1320 providing and placing on terrace (at all floor levels) polyethylene water storage tank, is : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 1321 rectangular tank 1322 providing and fixing c.p. brass bib cock of approved quality conforming to is:8931 : 1323 15 mm nominal bore 1324 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 1325 15 mm nominal bore 1326 providing and fixing c.p. brass stop cock (concealed) of standard design and of approved make conforming to is:8931. 1327 15 mm nominal bore. 1328 providing and fixing c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 1329 15 mm nominal bore 1330 providing and fixing ptmt grating of approved quality and colour. 1331 circular type. 1332 100 mm nominal dia. 1333 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 1334 sewarage & drainage 1335 providing and fixing square mouth s.w. gully trap class sp 1 complete with c.i. grating brick masonry chamber with water tight c.i. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70kg as per standard design: 1336 150 x 100 mm size p type 1337 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 1338 making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 1339 for pipes 100 to 250 mm diameter 1340 providing, laying and jointing non pressure np2 class (light duty)rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 1341 150 mm dia rcc pipe 1342 subhead i wiring 1343 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. 1344 group c 1345 wiring for light/ power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 1346 supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 1347 4 module (125 mmx75 mm) 1348 supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1349 15/16 a switch 1350 3 pin 5/6 a socket outlet 1351 telephone socket outlet 1352 tv antenna socket outlet 1353 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 1354 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire 1355 2 x 10 sq. mm + 1 x 6 sq. mm earth wire 1356 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface/ recessed steel/ pvc conduit as required. 1357 supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 1358 1 or 2 module (75 mmx75 mm) 1359 supplying and drawing following pair 0.5 mm dia frls pvc insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ pvc conduit as required. 1360 2 pair 1361 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1362 20 mm 1363 25 mm 1364 providing and fixing in position 2mm thick m.s. telephone junction box of size suitable for fixing of following krone tag block with key lock arrangement. also provide clamps for fixing tag blocks. 1365 10 pair telephone tag blockwith box 1366 supplying, laying of 10 pair unarmoured pvc insulated copper conductor (atc) telephone cable in ground/existing pipes/on wall and making connection with telephone main junction box (mdf) including supports and all accessories as required 1367 10 pair cable unarmoured 1368 subhead ii supply & installation of fittings 1369 supplying of following box type fl. fitting made out of crca sheet finished in antirust treated non yellowing super white stove enamelled paint duly wired with copper wound heavy duty choke starter holder, starter but without lamp complete etc. as reqd. 1370 mounting rail for tled lamps 1600 lumens (tmc 501 p 1xt led with essential led 18w tube) 1371 supplying of wall bracket light fittings suitable for 11 / 13 w cfl lamp. the fitting shall be made up of m.s. powder coated provided with integral ballast, frosted glass and 1 no. 11 / 13 wlamp duly wired upto the connector block complete as required. (decon cat. no.05aam) 1372 supplying of ceiling light fittings suitable for 1 x 15/20 w led lamp. the fitting shall be made up of m.s. powder coated provided with electronic ballast, 1 no. 15/20 w led lamp duly wired upto the connector block etc. complete as required. 1373 cirrus mini pro 15 / 20 watt & 1100 /1600 lumens (philips sm200c led11s 6500 psu od wh) 1374 supplying of bulk head fittings suitable for 10 w led lamp complete with ballast & accessories such as glass, wire guard, 60 w cfl lamp etc. complete as required. 1375 endural led bulkhead, 10 w, 600 lumen such as (philips wt202w led6s cw psu s2 pc) 1376 supplying of exhaustfan, all complete with mounting ring frame i/c bracket,but without regulator with shutters in the following sizes. (g.e. alsthom, khaitan & havells company) 1377 300 mm 4 pole 1378 supplying of 1400 mm sweep a.c. electric ceiling fans, capacitor type with double ball bearing complete with 300 mm down rod, canopies, shackles, blades, but without regulator suitable for operation on 230 / 240 volts, 50 hz, single phase, a.c. supply. (crompton, khaitan & havells company) 1379 supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 1380 installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 1381 installation, testing and commissioning of pre wired, light fixture / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 1382 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 1383 upto 450 mm sweep 1384 extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. 1385 installation, testing and commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two gls/cfl/ led lamps per fitting, complete with all accessories including connections etc. as required. 1386 supplying and fixing call bell/ buzzer suitable for single phase, 230 v, complete as required. 1387 subhead iii distribution board 1388 supplying, installing, testing and commissioning of compartmentalised cubical type meter board for installation of single phase meter. the cubical board shall be made of 2mm thick c.r.c.a sheet, duly phosphatised powder coated complete with connection bus bar and following accessories mounted in it. 1389 meter board 1390 incoming : 1391 40a tp mccb having breaking capacity 25 ka 1 no. 1392 outgoing : 1393 space for single phase energy meter 4 nos. 1394 25 amp dp mcb 4 nos. 1395 supplying, installing, testing & commissioning of single phase electronic energy meter, tested as per electricity boards requirement. 1396 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 1397 12 way, spn 1398 supplying and fixing following rating, double pole, 240 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 1399 40 amps 1400 supplying and fixing following rating, double pole, (single phase and neutral), 240 v, residual current circuit breaker (rccb), having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. asrequired. 1401 25 amps 1402 supplying of xlpe insulated, pvc sheathed 1.1 kv grade aluminium conductor heavy duty armoured cable as per is : 7098 of size : 1403 4 x 16 sq.mm. 1404 providing, laying and fixing following dia rcc pipe np2 class (light duty) in ground complete with rcc collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required for crossing road/walls 1405 100 mm dia 1406 supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 1407 single pole 1408 subhead iv earthing 1409 earthing with g.i. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 1410 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re filling as required. 1411 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 1412 earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1413 all kinds of soil 1414 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 1415 excavating, supplying and filling of local earth (including royalty)by mechanical transport upto a lead of 5km also includingramming and watering of the earth in layers not exceeding 20cm in trenches, plinth, sides of foundation etc. complete. 1416 concrete work 1417 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 1418 1:5:10 (1 cement : 5 coarse sand (zone iii) : 10 graded stone aggregate 40 mm nominal size) 1419 providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : 1420 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). 1421 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 1422 providing and laying damp proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone iii): 4 graded stone aggregate 12.5mm nominal size) 1423 providing & applying a coat of residual petroleum bitumen of grade of vg 10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 1424 reinforcedcementconcrete 1425 centering and shuttering including strutting, propping etc. and removal of form for all heights: 1426 foundations, footings, bases of columns, etc. for mass concrete 1427 columns, pillars, piers, abutments, posts and struts 1428 small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like 1429 edges of slabs and breaks in floors and walls 1430 under 20 cms wide 1431 suspended floors, roofs, landings, balconies and access platform. 1432 lintels, beams, plinth beams, girders, bressumers and cantilevers. 1433 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 1434 thermo mechanically treated bars of grade fe 500d or more. 1435 add for plaster drip course/ groove in plastered surface or moulding to r.c.c. projections. 1436 providing and laying in position machine batched and machine mixed design mix m 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per is: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of engineer in charge.“(note : cement content considered in this item is @ 330 kg/cum.“excess/ less cement used as per design mix is payable/recoverable separately). 1437 all works upto plinth level 1438 all works above plinth level upto floor v level 1439 brick work 1440 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in foundation and plinth in: 1441 cement mortar 1:6 (1 cement : 6 coarse sand) 1442 providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick aac blocks in super structure above plinth level up to floor v level with rcc band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of engineer in charge. (the payment of rcc band and reinforcement shall be made for seperately). 1443 half brick masonry with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level. 1444 cement mortar 1:4 (1 cement :4 coarse sand) 1445 extra for providing and placing in position 2 nos 6mm dia. m.s. bars at every third course of half brick masonry. 1446 brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand). 1447 marble work 1448 providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 1449 granite of any colour and shade 1450 area of slab over 0.50 sqm 1451 providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer in charge. 1452 granite work 1453 extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. 1454 wood work & pvc work 1455 providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). 1456 second class teak wood 1457 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 1458 25 mm thick (for cupboard) including isi marked nickel plated bright finished m.s. piano hinges is : 3818 marked with necessary screws 1459 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1460 35 mm thick including isi marked stainless steel butt hinges with necessary screws 1461 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 1462 providing and fixing wire gauge shutters using galvanized m.s. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 1463 35 mm thick shutters 1464 kiln seasoned and chemically treated hollock wood 1465 providing and fixing aluminium sliding door bolts, isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 1466 250x16 mm 1467 providing and fixing aluminium tower bolts, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 1468 200x10 mm 1469 providing and fixing aluminium handles, isi marked, anodised (anodiccoating not less than grade ac 10 as per is : 1868) transparent or dyedto required colour or shade, with necessary screws etc. complete : 1470 125 mm 1471 providing and fixing aluminium hanging floor door stopper, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. 1472 twin rubber stopper 1473 providing and fixing pre laminated flat pressed 3 layer (medium density)particle board or graded wood particle board is : 3087 marked, with oneside decorative and other side balancing lamination grade i, type iiexterior grade is : 12823 marked, in shelves with screws and fittingswherever required, edges to be painted with polyurethane primer (fittingsto be paid separately). 1474 18 mm thick 1475 providing and fixing factory made upvc white colour sliding glazed window upto 1.50 m in height dimension comprising of upvc multi chambered frame with in built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to upvc profile), appropriate dimension of upvc extruded glazing beads and upvc extruded interlocks, epdm gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), g.i fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of engineer in charge. (single / double glass panes, wire mesh and silicon sealent shall be paid separately). variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 1476 three track three panels sliding window with fly proof s.s wire mesh (two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (area of window above 1.75 sqm). 1477 providing and fixing isi marked oxidised m.s. single acting spring hingeswith necessary screws etc. complete : 1478 150 mm 1479 providing and fixing oxidised m.s. hasp and staple (safety type)conforming to is : 363 with necessary screws etc. complete : 1480 90 mm 1481 providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 1482 75 mm 1483 providing and fixing wooden moulded corner beading of triangular shape to the junction of panelling etc. with iron screws, plugs and priming coat on unexposed surface etc. complete 2nd class teak wood. 1484 50x50 mm (base and height) 1485 float glass panes 1486 4 mm thick glass pane (weight not less than 10kg/sqm). 1487 steel work 1488 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 1489 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1490 providing and fixing t iron frames for doors, windows and ventilators of mild steel tee sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 1491 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1492 providing and fixing circular/ hexagonal cast iron or m.s. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick m.s. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ m.s. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. clamp shall be made of 12 mm dia m.s. bar bent to shape as per standard drawing. 1493 providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. 1494 m.s. tube 1495 providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 1496 4.0 mm thick glass panes 1497 flooring 1498 providing and fixing glass strips in joints of terrazo/ cement concrete floors. 1499 40 mm wide and 4 mm thick 1500 kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 1501 25 mm thick. 1502 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 1503 extra for pre finished nosing in treads of steps of kota stone/ sand stone slab. 1504 extra for kota stone/ sand stone in treads of steps and risers using single length up to 1.05 metre. 1505 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 1506 providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand),jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 1507 size of tile 600x600 mm 1508 providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. 1509 size of tile 400x400 mm 1510 roofing 1511 providing and laying brick tiles over mumty roofs, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat. 1512 with common burnt clay f.p.s. (non modular) brick tilesof class designation 10 1513 making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over p.v.c. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 1514 finishing 1515 12 mm cement plaster of mix 1516 1:6 (1 cement: 6 coarse sand) 1517 15 mm cement plaster on rough side of single or half brick wall of mix: 1518 1:6 (1 cement: 6 coarse sand) 1519 white washing with lime to give an even shade : 1520 new work (three or more coats) 1521 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1522 new work (two or more coats) over and including water thinnable priming coat with cement primer 1523 finishing walls with premium acrylic smooth exterior paint withsilicone additives of required shade: 1524 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 1525 applying priming coat: 1526 with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 1527 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 1528 painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 1529 two or more coats on new work 1530 water proofing 1531 providing and laying in situ seven course water proofing treatment with app (atactic poly propylene) modified polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to is : 702, 3rd and 5th layers of roofing membrane app modified polymeric membrane 1.5 mm thick of 2.25 kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron hmhdpe film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron hmhdpe film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately). 1532 providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of w.c., kitchen and the like consisting of: 1533 ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to is 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. 1534 iind course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. 1535 iiird course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. 1536 ivth course of 400 micron thick pvc sheet. (overlaps at joints of pvc sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/ sqm). 1537 non shedule items 1538 providing and laying cinder filling in sunken floors and other locationswith approved quality cinder including watering and light ramming etc.required for proper compaction/completion of the work complete in all respects as per drawings and as directed by the engineer in charge. 1539 providing and laying 1st quality ceramic glazed anti skid floortiles of size 300x300 mm (thickness to be specified by the manufacturer) conforming to is:15622 in all colours, shades, sizes as approved over 20 mm thick bed of cement mortar 1: 4 (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc complete in all respects as per specifications/drawings and to the entire satisfaction to the architect. 1540 earth work 1541 earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1542 all kinds of soil. 1543 excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 1544 all kinds of soil 1545 pipes, cables etc, not exceeding 80 mm dia. 1546 pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 1547 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 1548 roofing 1549 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 1550 110 mm diameter 1551 providing and fixing on wall face unplasticised pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 1552 coupler 1553 110 mm 1554 bend 87.5° 1555 110 mm bend 1556 shoe (plain) 1557 110 mm shoe 1558 providing and fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with m.s. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 1559 110 mm 1560 providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 1561 sanitary installations 1562 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1563 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 1564 providing and fixing white vitreous china pedestal type water closet (european type w.c. pan) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. 1565 w.c. pan with isi marked white solid plastic seat and lid 1566 providing and fixing wash basin with c.i. brackets, 15 mm c.p. brass pillar taps, 32 mm c.p. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 1567 white vitreous china flat back wash basin size 550x 400 mm with single 15 mm c.p. brass pillar tap 1568 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is: 13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 1569 kitchen sink with drain board 1570 510x1040 mm bowl depth 250 mm 1571 extra for using coloured pedestal type w.c pan (european type) with low level cistern of same colour instead of white vitreous china w.c pan and cistern. 1572 providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with c.p. brass screws and washers complete. 1573 providing and fixing toilet paper holder : 1574 vitreous china 1575 providing and fixing soil, waste and vent pipes : 1576 100 mm dia. 1577 centrifugally cast (spun) iron socket & spigot (s&s) pipe as per is: 3989 1578 75mm diameter 1579 centrifugally cast (spun) iron socketed pipe as per is: 3989 1580 providing and fixing m.s. holder bat clamps of approved design to sand cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : 1581 for 100 mm dia. pipe 1582 for 75 mm dia. pipe 1583 providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 1584 100 mm 1585 sand cast iron s&s as per is 3989 1586 75 mm 1587 sand cast iron s&s as per is 3989 1588 providing and fixing plain bend of required degree. 1589 100 mm 1590 sand cast iron s&s as per is : 3989 1591 75 mm 1592 sand cast iron s&s as per is 3989 1593 providing and fixing heel rest sanitary bend 1594 100 mmdia 1595 sand cast iron s&s as per is 3989 1596 75 mm dia 1597 sand cast iron s&s as per is 3989 1598 providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3mm thick,bolts and nuts complete. 1599 100x100x100mm 1600 sand cast iron s&s as per is 3989 1601 75x75x75mm 1602 sand cast iron s&s as per is 3989 1603 providing and fixing single equal plain junction of required degree 1604 100x100x100mm 1605 sand cast iron s&s as per is 3989 1606 75x75x75mm 1607 sand cast iron s&s as per is 3989 1608 providing and fixing door piece, insertion rubber washer 3mm thick, bolts & nuts complete : 1609 100 mm 1610 sand cast iron s&s as per is 3989 1611 75 mm 1612 sand cast iron s&s as per is 3989 1613 providing and fixing terminal guard : 1614 100 mm 1615 sand cast iron s&s as per is 3989 1616 75 mm 1617 sand cast iron s&s as per is 3989 1618 providing and fixing collar : 1619 100 mm 1620 sand cast iron s&s as per is 3989 1621 75 mm 1622 sand cast iron s&s as per is 3989 1623 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : 1624 100 mm 1625 75 mm 1626 providing and fixing m.s. stays and clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter : 1627 100 mm 1628 75 mm 1629 providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 1630 100 mm inlet and 100 mm outlet 1631 sand cast iron s&s as per is: 1729 1632 cutting chases in brick masonry walls for following diameter sand cast iron/ centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : 1633 100 mm dia 1634 painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work : 1635 100 mm diameter pipe 1636 75 mm diameter pipe 1637 providing and fixing ptmt waste coupling for wash basin and sink, of approved quality and colour. 1638 waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms 1639 providing and fixing ptmt bottle trap for wash basin and sink. 1640 bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms 1641 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 1642 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour. 1643 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 1644 providing and fixing g.i. pipes complete with g.i. fittings including trenching & refilling. 1645 external work 1646 32mmdia nominal bore 1647 40mmdia nominal bore 1648 50mmdia nominal bore 1649 water supply 1650 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 1651 internal work exposed on wall 1652 25 mm nominal outer dia pipes metre 1653 32 mm nominal outer dia pipes metre 1654 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 1655 concealed work, including cutting chases and making good the walls etc. 1656 15 mm nominal outer dia pipes 1657 20 mm nominal outer dia pipes 1658 making connection of g.i. distribution branch with g.i. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 1659 25 to 40 mm nominal bore 1660 providing and fixing brass stop cock of approved quality : 1661 15 mm nominal bore 1662 20 mm nominal bore 1663 providing and fixing gun metal gate valve with c.i. wheel of approved quality (screwed end) : 1664 25mm nominal bore 1665 32mm nominal bore 1666 40mm nominal bore 1667 providing and fixing ball valve (brass) of approved quality, high or low pressure, with plastic floats complete : 1668 25 mm nominal bore 1669 providing and fixing brass ferrule with c.i. mouth cover including boring and tapping the main : 1670 25 mm nominal bore 1671 providing and fixing uplasticised pvc connection pipe with brass unions : 1672 45 cm length 1673 15 mm nominal bore 1674 providing and fixing c.p. brass shower rose with 15 or 20 mm inlet : 1675 100 mm diameter 1676 providing and placing on terrace (at all floor levels) polyethylene water storage tank, is : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 1677 rectangular tank 1678 providing and fixing c.p. brass bib cock of approved quality conforming to is:8931 : 1679 15 mm nominal bore 1680 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 1681 15 mm nominal bore 1682 providing and fixing c.p. brass stop cock (concealed) of standard design and of approved make conforming to is:8931. 1683 15 mm nominal bore. 1684 providing and fixing c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 1685 15 mm nominal bore 1686 providing and fixing ptmt grating of approved quality and colour. 1687 circular type. 1688 100 mm nominal dia. 1689 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 1690 sewarage & drainage 1691 providing, laying and jointing glazed stoneware pipes class sp 1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 1692 100 mm diameter 1693 150 mm diameter 1694 providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all round s.w. pipes including bed concrete as per standard design : 1695 100 mm diameter s.w. pipe 1696 150 mm diameter s.w. pipe 1697 providing and fixing square mouth s.w. gully trap class sp 1 complete with c.i. grating brick masonry chamber with water tight c.i. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70kg as per standard design: 1698 150 x 100 mm size p type 1699 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 1700 providing, laying and jointing non pressure np2 class (light duty)rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 1701 150 mm dia rcc pipe 1702 subhead i wiring 1703 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. 1704 group c 1705 wiring for light/ power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 1706 supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 1707 4 module (125 mmx75 mm) 1708 supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 1709 15/16 a switch 1710 3 pin 5/6 a socket outlet 1711 telephone socket outlet 1712 tv antenna socket outlet 1713 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 1714 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire 1715 2 x 10 sq. mm + 1 x 6 sq. mm earth wire 1716 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface/ recessed steel/ pvc conduit as required. 1717 supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 1718 25 mm 1719 supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 1720 1 or 2 module (75 mmx75 mm) 1721 supplying and drawing following pair 0.5 mm dia frls pvc insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ pvc conduit as required. 1722 2 pair 1723 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 1724 20 mm 1725 25 mm 1726 providing and fixing in position 2mm thick m.s. telephone junction box of size suitable for fixing of following krone tag block with key lock arrangement. also provide clamps for fixing tag blocks. 1727 10 pair telephone tag blockwith box 1728 supplying, laying of 10 pair unarmoured pvc insulated copper conductor (atc) telephone cable in ground/existing pipes/on wall and making connection with telephone main junction box (mdf) including supports and all accessories as required 1729 10 pair cable unarmoured 1730 subhead ii supply & installation of fittings 1731 supplying of following box type fl. fitting made out of crca sheet finished in antirust treated non yellowing super white stove enamelled paint duly wired with copper wound heavy duty choke starter holder, starter but without lamp complete etc. as reqd. 1732 mounting rail for tled lamps 1600 lumens (tmc 501 p 1xt led with essential led 18w tube) 1733 supplying of wall bracket light fittings suitable for 11 / 13 w cfl lamp. the fitting shall be made up of m.s. powder coated provided with integral ballast, frosted glass and 1 no. 11 / 13 wlamp duly wired upto the connector block complete as required. (decon cat. no.05aam) 1734 supplying of ceiling light fittings suitable for 1 x 15/20 w led lamp. the fitting shall be made up of m.s. powder coated provided with electronic ballast, 1 no. 15/20 w led lamp duly wired upto the connector block etc. complete as required. 1735 cirrus mini pro 15 / 20 watt & 1100 /1600 lumens (philips sm200c led11s 6500 psu od wh) 1736 supplying of bulk head fittings suitable for 10 w led lamp complete with ballast & accessories such as glass, wire guard, 60 w cfl lamp etc. complete as required. 1737 endural led bulkhead, 10 w, 600 lumen such as (philips wt202w led6s cw psu s2 pc) 1738 supplying of exhaustfan, all complete with mounting ring frame i/c bracket,but without regulator with shutters in the following sizes. (g.e. alsthom, khaitan & havells company) 1739 300 mm 4 pole 1740 supplying of 1400 mm sweep a.c. electric ceiling fans, capacitor type with double ball bearing complete with 300 mm down rod, canopies, shackles, blades, but without regulator suitable for operation on 230 / 240 volts, 50 hz, single phase, a.c. supply. (crompton, khaitan & havells company) 1741 supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 1742 installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 1743 installation, testing and commissioning of pre wired, light fixture / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 1744 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 1745 upto 450 mm sweep 1746 extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. 1747 installation, testing and commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two gls/cfl/ led lamps per fitting, complete with all accessories including connections etc. as required. 1748 supplying and fixing call bell/ buzzer suitable for single phase, 230 v, complete as required. 1749 subhead iii distribution board 1750 supplying, installing, testing and commissioning of compartmentalised cubical type meter board for installation of single phase meter. the cubical board shall be made of 2mm thick c.r.c.a sheet, duly phosphatised powder coated complete with connection bus bar and following accessories mounted in it. 1751 meter board 1752 incoming : 1753 40a tp mccb having breaking capacity 25 ka 1 no. 1754 outgoing : 1755 space for single phase energy meter 4 nos. 1756 25 amp dp mcb 4 nos. 1757 supplying, installing, testing & commissioning of single phase electronic energy meter, tested as per electricity boards requirement. 1758 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 1759 12 way, spn 1760 supplying and fixing following rating, double pole, 240 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 1761 40 amps 1762 supplying and fixing following rating, double pole, (single phase and neutral), 240 v, residual current circuit breaker (rccb), having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. asrequired. 1763 25 amps 1764 supplying of xlpe insulated, pvc sheathed 1.1 kv grade aluminium conductor heavy duty armoured cable as per is : 7098 of size : 1765 4 x 16 sq.mm. 1766 providing, laying and fixing following dia rcc pipe np2 class (light duty) in ground complete with rcc collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required for crossing road/walls 1767 100 mm dia 1768 supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 1769 single pole 1770 subhead iv earthing 1771 earthing with g.i. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 1772 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re filling as required. 1773 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 1774 subhead v lightning conductor 1775 providing and fixing of lightning conductor finial, made of 25mm dia 300 mm long, g.i. tube, having single prong at top, with85 mm dia 6 mm thick g.i. base plate including holes etc.complete as required. 1776 jointing copper / g.i. tape (with another copper/ g i tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 1777 fixing of copper/ g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for horizontal run) 1778 fixing of copper/ g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for vertical run) 1779 providing and fixing testing joint, made of 20 mm x 3 mm thickg.i. strip, 125 mm long, with 4 nos. of g.i. bolts, nuts, chucknuts and spring washers etc. complete as required. 1780 laying copper/ g.i. tape 32 mm x 6 mm from earth electrodedirectly in ground as required 1781 earth work 1782 earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1783 all kinds of soil 1784 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 1785 excavating, supplying and filling of local earth (including royalty)by mechanical transport upto a lead of 5km also includingramming and watering of the earth in layers not exceeding 20cm in trenches, plinth, sides of foundation etc. complete. 1786 concrete work 1787 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 1788 1:5:10 (1 cement : 5 coarse sand (zone iii) : 10 graded stone aggregate 40 mm nominal size) 1789 providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : 1790 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). 1791 providing and laying damp proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone iii): 4 graded stone aggregate 12.5mm nominal size) 1792 providing & applying a coat of residual petroleum bitumen of grade of vg 10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 1793 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 1794 reinforcedcementconcrete 1795 centering and shuttering including strutting, propping etc. and removal of form for all heights: 1796 foundations, footings, bases of columns, etc. for mass concrete 1797 walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc 1798 columns, pillars, piers, abutments, posts and struts 1799 small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like 1800 edges of slabs and breaks in floors and walls 1801 under 20 cms wide 1802 suspended floors, roofs, landings, balconies and access platform. 1803 lintels, beams, plinth beams, girders, bressumers and cantilevers. 1804 steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 1805 thermo mechanically treated bars of grade fe 500d or more. 1806 add for plaster drip course/ groove in plastered surface or moulding to r.c.c. projections. 1807 providing and laying in position machine batched and machine mixed design mix m 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per is: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of engineer in charge.“(note : cement content considered in this item is @ 330 kg/cum.“excess/ less cement used as per design mix is payable/recoverable separately). 1808 all works upto plinth level 1809 all works above plinth level upto floor v level 1810 brick work 1811 brick work with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in foundation and plinth in: 1812 cement mortar 1:6 (1 cement : 6 coarse sand) 1813 providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick aac blocks in super structure above plinth level up to floor v level with rcc band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of engineer in charge. (the payment of rcc band and reinforcement shall be made for seperately). 1814 half brick masonry with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor v level. 1815 cement mortar 1:4 (1 cement :4 coarse sand) 1816 extra for providing and placing in position 2 nos 6mm dia. m.s. bars at every third course of half brick masonry. 1817 brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand). 1818 marble work 1819 providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 1820 granite of any colour and shade 1821 area of slab over 0.50 sqm 1822 providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer in charge. 1823 granite work 1824 extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. 1825 wood work & pvc work 1826 providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). 1827 second class teak wood 1828 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 1829 25 mm thick (for cupboard) including isi marked nickel plated bright finished m.s. piano hinges is : 3818 marked with necessary screws 1830 providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) non decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 1831 35 mm thick including isi marked stainless steel butt hinges with necessary screws 1832 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 1833 providing and fixing wire gauge shutters using galvanized m.s. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 1834 35 mm thick shutters 1835 kiln seasoned and chemically treated hollock wood 1836 providing and fixing aluminium sliding door bolts, isi marked anodised (anodic coating not less than grade ac 10 as per is : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 1837 250x16 mm 1838 providing and fixing aluminium tower bolts, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 1839 200x10 mm 1840 providing and fixing aluminium handles, isi marked, anodised (anodiccoating not less than grade ac 10 as per is : 1868) transparent or dyedto required colour or shade, with necessary screws etc. complete : 1841 125 mm 1842 providing and fixing aluminium hanging floor door stopper, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. 1843 twin rubber stopper 1844 providing and fixing pre laminated flat pressed 3 layer (medium density)particle board or graded wood particle board is : 3087 marked, with oneside decorative and other side balancing lamination grade i, type iiexterior grade is : 12823 marked, in shelves with screws and fittingswherever required, edges to be painted with polyurethane primer (fittingsto be paid separately). 1845 18 mm thick 1846 providing and fixing factory made upvc white colour sliding glazed window upto 1.50 m in height dimension comprising of upvc multi chambered frame with in built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to upvc profile), appropriate dimension of upvc extruded glazing beads and upvc extruded interlocks, epdm gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), g.i fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. after fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of engineer in charge. (single / double glass panes, wire mesh and silicon sealent shall be paid separately). variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. 1847 three track three panels sliding window with fly proof s.s wire mesh (two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (area of window above 1.75 sqm). 1848 providing and fixing isi marked oxidised m.s. single acting spring hingeswith necessary screws etc. complete : 1849 150 mm 1850 providing and fixing oxidised m.s. hasp and staple (safety type)conforming to is : 363 with necessary screws etc. complete : 1851 90 mm 1852 providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 1853 75 mm 1854 providing and fixing wooden moulded corner beading of triangular shape to the junction of panelling etc. with iron screws, plugs and priming coat on unexposed surface etc. complete 2nd class teak wood. 1855 50x50 mm (base and height) 1856 float glass panes 1857 4 mm thick glass pane (weight not less than 10kg/sqm). 1858 steel work 1859 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). 1860 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1861 providing and fixing t iron frames for doors, windows and ventilators of mild steel tee sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 1862 fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of c.c. 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 1863 providing and fixing circular/ hexagonal cast iron or m.s. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick m.s. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ m.s. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. clamp shall be made of 12 mm dia m.s. bar bent to shape as per standard drawing. 1864 providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. 1865 m.s. tube 1866 providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 1867 4.0 mm thick glass panes 1868 flooring 1869 providing and fixing glass strips in joints of terrazo/ cement concrete floors. 1870 40 mm wide and 4 mm thick 1871 kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 1872 25 mm thick. 1873 kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 1874 extra for pre finished nosing in treads of steps of kota stone/ sand stone slab. 1875 extra for kota stone/ sand stone in treads of steps and risers using single length up to 1.05 metre. 1876 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 1877 providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand),jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 1878 size of tile 600x600 mm 1879 providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. 1880 size of tile 400x400 mm 1881 roofing 1882 providing and laying brick tiles over mumty roofs, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat. 1883 with common burnt clay f.p.s. (non modular) brick tilesof class designation 10 1884 making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over p.v.c. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 1885 finishing 1886 12 mm cement plaster of mix 1887 1:6 (1 cement: 6 coarse sand) 1888 15 mm cement plaster on rough side of single or half brick wall of mix: 1889 1:6 (1 cement: 6 coarse sand) 1890 white washing with lime to give an even shade : 1891 new work (three or more coats) 1892 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1893 new work (two or more coats) over and including water thinnable priming coat with cement primer 1894 finishing walls with premium acrylic smooth exterior paint withsilicone additives of required shade: 1895 new work (two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 1896 applying priming coat: 1897 with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 1898 with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works 1899 painting with synthetic enamel paint of approved brand and manufacture to give an even shade : 1900 two or more coats on new work 1901 water proofing 1902 providing and laying in situ seven course water proofing treatment with app (atactic poly propylene) modified polymeric memberane over roof consisting of first coat of bitumen primer @ 0.40 litre per sqm, 2nd, 4th & 6th courses of bonding material @ 1.20 kg/sqm, which shall consist of blown type bitumen of grade 85/25 conforming to is : 702, 3rd and 5th layers of roofing membrane app modified polymeric membrane 1.5 mm thick of 2.25 kg/sqm weight consisting of five layers prefabricated with centre core as 20 micron hmhdpe film sandwiched on both sides with polymeric mix and the polymeric mix is protected on both side with 20 micron hmhdpe film. 7th, the top most layer shall be finished with brick tiles of class designation 10 grouted with cement mortar 1:3 (1cement : 3 fine sand) mixed with 2% integral water proofing compound by weight of cement over a 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat (item of laying brick tiles shall be paid for separately). 1903 applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to is. 2645 and approved by engineer in charge over the rcc slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. 1904 laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to is : 2645 and approved by engineerin charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to is : 2645 and approved by engineerin charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. 1905 after two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to is : 2645 and approved by engineer in charge. 1906 finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to is : 2645 and approved by engineer in charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. 1907 the whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“all above operations to be done in order and as directed and specified by the engineer in charge : 1908 the 1909 providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of w.c., kitchen and the like consisting of: 1910 ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to is 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. 1911 iind course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. 1912 iiird course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. 1913 ivth course of 400 micron thick pvc sheet. (overlaps at joints of pvc sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/ sqm). 1914 non shedule items 1915 providing and laying cinder filling in sunken floors and other locationswith approved quality cinder including watering and light ramming etc.required for proper compaction/completion of the work complete in all respects as per drawings and as directed by the engineer in charge. 1916 providing and laying 1st quality ceramic glazed anti skid floortiles of size 300x300 mm (thickness to be specified by the manufacturer) conforming to is:15622 in all colours, shades, sizes as approved over 20 mm thick bed of cement mortar 1: 4 (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc complete in all respects as per specifications/drawings and to the entire satisfaction to the architect. 1917 earth work 1918 earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 1919 all kinds of soil. 1920 excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 1921 all kinds of soil 1922 pipes, cables etc, not exceeding 80 mm dia. 1923 pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 1924 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 1925 roofing 1926 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, (i) single socketed pipes. 1927 110 mm diameter 1928 providing and fixing on wall face unplasticised pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion. 1929 coupler 1930 110 mm 1931 bend 87.5° 1932 110 mm bend 1933 shoe (plain) 1934 110 mm shoe 1935 providing and fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with m.s. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 1936 110 mm 1937 providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 1938 sanitary installations 1939 providing and fixing water closet squatting pan (indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 1940 white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests 1941 providing and fixing white vitreous china pedestal type water closet (european type w.c. pan) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. 1942 w.c. pan with isi marked white solid plastic seat and lid 1943 providing and fixing wash basin with c.i. brackets, 15 mm c.p. brass pillar taps, 32 mm c.p. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 1944 white vitreous china flat back wash basin size 550x 400 mm with single 15 mm c.p. brass pillar tap 1945 providing and fixing stainless steel a isi 304 (18/8) kitchen sink as per is: 13983 with c.i. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 1946 kitchen sink with drain board 1947 510x1040 mm bowl depth 250 mm 1948 extra for using coloured pedestal type w.c pan (european type) with low level cistern of same colour instead of white vitreous china w.c pan and cistern. 1949 providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with c.p. brass screws and washers complete. 1950 providing and fixing toilet paper holder : 1951 vitreous china 1952 providing and fixing soil, waste and vent pipes : 1953 100 mm dia. 1954 centrifugally cast (spun) iron socket & spigot (s&s) pipe as per is: 3989 1955 75mm diameter 1956 centrifugally cast (spun) iron socketed pipe as per is: 3989 1957 providing and fixing m.s. holder bat clamps of approved design to sand cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : 1958 for 100 mm dia. pipe 1959 for 75 mm dia. pipe 1960 providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 1961 100 mm 1962 sand cast iron s&s as per is 3989 1963 75 mm 1964 sand cast iron s&s as per is 3989 1965 providing and fixing plain bend of required degree. 1966 100 mm 1967 sand cast iron s&s as per is : 3989 1968 75 mm 1969 sand cast iron s&s as per is 3989 1970 providing and fixing heel rest sanitary bend 1971 100 mmdia 1972 sand cast iron s&s as per is 3989 1973 75 mm dia 1974 sand cast iron s&s as per is 3989 1975 providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3mm thick,bolts and nuts complete. 1976 100x100x100mm 1977 sand cast iron s&s as per is 3989 1978 75x75x75mm 1979 sand cast iron s&s as per is 3989 1980 providing and fixing single equal plain junction of required degree 1981 100x100x100mm 1982 sand cast iron s&s as per is 3989 1983 75x75x75mm 1984 sand cast iron s&s as per is 3989 1985 providing and fixing door piece, insertion rubber washer 3mm thick, bolts & nuts complete : 1986 100 mm 1987 sand cast iron s&s as per is 3989 1988 75 mm 1989 sand cast iron s&s as per is 3989 1990 providing and fixing terminal guard : 1991 100 mm 1992 sand cast iron s&s as per is 3989 1993 75 mm 1994 sand cast iron s&s as per is 3989 1995 providing and fixing collar : 1996 100 mm 1997 sand cast iron s&s as per is 3989 1998 75 mm 1999 sand cast iron s&s as per is 3989 2000 providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : 2001 100 mm 2002 75 mm 2003 providing and fixing m.s. stays and clamps for sand cast iron/ centrifugally cast (spun) iron pipes of diameter : 2004 100 mm 2005 75 mm 2006 providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 2007 100 mm inlet and 100 mm outlet 2008 sand cast iron s&s as per is: 1729 2009 cutting chases in brick masonry walls for following diameter sand cast iron/ centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand) : 2010 100 mm dia 2011 painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work : 2012 100 mm diameter pipe 2013 75 mm diameter pipe 2014 providing and fixing ptmt waste coupling for wash basin and sink, of approved quality and colour. 2015 waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms 2016 providing and fixing ptmt bottle trap for wash basin and sink. 2017 bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms 2018 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 2019 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour. 2020 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. 2021 providing and fixing g.i. pipes complete with g.i. fittings including trenching & refilling. 2022 external work 2023 32mmdia nominal bore 2024 40mmdia nominal bore 2025 50mmdia nominal bore 2026 water supply 2027 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 2028 internal work exposed on wall 2029 25 mm nominal outer dia pipes metre 2030 32 mm nominal outer dia pipes metre 2031 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. 2032 concealed work, including cutting chases and making good the walls etc. 2033 15 mm nominal outer dia pipes 2034 20 mm nominal outer dia pipes 2035 making connection of g.i. distribution branch with g.i. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 2036 25 to 40 mm nominal bore 2037 providing and fixing brass stop cock of approved quality : 2038 15 mm nominal bore 2039 20 mm nominal bore 2040 providing and fixing gun metal gate valve with c.i. wheel of approved quality (screwed end) : 2041 25mm nominal bore 2042 32mm nominal bore 2043 40mm nominal bore 2044 providing and fixing ball valve (brass) of approved quality, high or low pressure, with plastic floats complete : 2045 25 mm nominal bore 2046 providing and fixing brass ferrule with c.i. mouth cover including boring and tapping the main : 2047 25 mm nominal bore 2048 providing and fixing uplasticised pvc connection pipe with brass unions : 2049 45 cm length 2050 15 mm nominal bore 2051 providing and fixing c.p. brass shower rose with 15 or 20 mm inlet : 2052 100 mm diameter 2053 providing and placing on terrace (at all floor levels) polyethylene water storage tank, is : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 2054 rectangular tank 2055 providing and fixing c.p. brass bib cock of approved quality conforming to is:8931 : 2056 15 mm nominal bore 2057 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms. 2058 15 mm nominal bore 2059 providing and fixing c.p. brass stop cock (concealed) of standard design and of approved make conforming to is:8931. 2060 15 mm nominal bore. 2061 providing and fixing c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 2062 15 mm nominal bore 2063 providing and fixing ptmt grating of approved quality and colour. 2064 circular type. 2065 100 mm nominal dia. 2066 cutting holes up to 15x15 cm in r.c.c. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 2067 sewarage & drainage 2068 providing, laying and jointing glazed stoneware pipes class sp 1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 2069 100 mm diameter 2070 150 mm diameter 2071 providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all round s.w. pipes including bed concrete as per standard design : 2072 100 mm diameter s.w. pipe 2073 150 mm diameter s.w. pipe 2074 providing and fixing square mouth s.w. gully trap class sp 1 complete with c.i. grating brick masonry chamber with water tight c.i. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70kg as per standard design: 2075 150 x 100 mm size p type 2076 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 2077 providing, laying and jointing non pressure np2 class (light duty)rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 2078 150 mm dia rcc pipe 2079 subhead i wiring 2080 wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class pvc conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. 2081 group c 2082 wiring for light/ power plug with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed medium class pvc conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. 2083 supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 2084 4 module (125 mmx75 mm) 2085 supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 2086 15/16 a switch 2087 3 pin 5/6 a socket outlet 2088 telephone socket outlet 2089 tv antenna socket outlet 2090 wiring for circuit/ submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2091 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire 2092 2 x 10 sq. mm + 1 x 6 sq. mm earth wire 2093 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface/ recessed steel/ pvc conduit as required. 2094 supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 2095 25 mm 2096 supplying and fixing following size/ modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. 2097 1 or 2 module (75 mmx75 mm) 2098 supplying and drawing following pair 0.5 mm dia frls pvc insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ pvc conduit as required. 2099 2 pair 2100 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 2101 20 mm 2102 25 mm 2103 providing and fixing in position 2mm thick m.s. telephone junction box of size suitable for fixing of following krone tag block with key lock arrangement. also provide clamps for fixing tag blocks. 2104 10 pair telephone tag blockwith box 2105 supplying, laying of 10 pair unarmoured pvc insulated copper conductor (atc) telephone cable in ground/existing pipes/on wall and making connection with telephone main junction box (mdf) including supports and all accessories as required 2106 10 pair cable unarmoured 2107 subhead ii supply & installation of fittings 2108 supplying of following box type fl. fitting made out of crca sheet finished in antirust treated non yellowing super white stove enamelled paint duly wired with copper wound heavy duty choke starter holder, starter but without lamp complete etc. as reqd. 2109 mounting rail for tled lamps 1600 lumens (tmc 501 p 1xt led with essential led 18w tube) 2110 supplying of wall bracket light fittings suitable for 11 / 13 w cfl lamp. the fitting shall be made up of m.s. powder coated provided with integral ballast, frosted glass and 1 no. 11 / 13 wlamp duly wired upto the connector block complete as required. (decon cat. no.05aam) 2111 supplying of ceiling light fittings suitable for 1 x 15/20 w led lamp. the fitting shall be made up of m.s. powder coated provided with electronic ballast, 1 no. 15/20 w led lamp duly wired upto the connector block etc. complete as required. 2112 cirrus mini pro 15 / 20 watt & 1100 /1600 lumens (philips sm200c led11s 6500 psu od wh) 2113 supplying of bulk head fittings suitable for 10 w led lamp complete with ballast & accessories such as glass, wire guard, 60 w cfl lamp etc. complete as required. 2114 endural led bulkhead, 10 w, 600 lumen such as (philips wt202w led6s cw psu s2 pc) 2115 supplying of exhaustfan, all complete with mounting ring frame i/c bracket,but without regulator with shutters in the following sizes. (g.e. alsthom, khaitan & havells company) 2116 300 mm 4 pole 2117 supplying of 1400 mm sweep a.c. electric ceiling fans, capacitor type with double ball bearing complete with 300 mm down rod, canopies, shackles, blades, but without regulator suitable for operation on 230 / 240 volts, 50 hz, single phase, a.c. supply. (crompton, khaitan & havells company) 2118 supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 2119 installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 2120 installation, testing and commissioning of pre wired, light fixture / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 2121 installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. 2122 upto 450 mm sweep 2123 extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. 2124 installation, testing and commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two gls/cfl/ led lamps per fitting, complete with all accessories including connections etc. as required. 2125 supplying and fixing call bell/ buzzer suitable for single phase, 230 v, complete as required. 2126 subhead iii distribution board 2127 supplying, installing, testing and commissioning of compartmentalised cubical type meter board for installation of single phase meter. the cubical board shall be made of 2mm thick c.r.c.a sheet, duly phosphatised powder coated complete with connection bus bar and following accessories mounted in it. 2128 meter board 2129 incoming : 2130 40a tp mccb having breaking capacity 25 ka 1 no. 2131 outgoing : 2132 space for single phase energy meter 4 nos. 2133 25 amp dp mcb 4 nos. 2134 supplying, installing, testing & commissioning of single phase electronic energy meter, tested as per electricity boards requirement. 2135 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator) 2136 12 way, spn 2137 supplying and fixing following rating, double pole, 240 v, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 2138 40 amps 2139 supplying and fixing following rating, double pole, (single phase and neutral), 240 v, residual current circuit breaker (rccb), having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. asrequired. 2140 25 amps 2141 supplying of xlpe insulated, pvc sheathed 1.1 kv grade aluminium conductor heavy duty armoured cable as per is : 7098 of size : 2142 4 x 16 sq.mm. 2143 providing, laying and fixing following dia rcc pipe np2 class (light duty) in ground complete with rcc collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required for crossing road/walls 2144 100 mm dia 2145 supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, “c” curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 2146 single pole 2147 subhead iv earthing 2148 earthing with g.i. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 2149 providing and laying earth connection from earth electrode with 6 swg dia g.i. wire in 15 mm dia g.i. pipe from earth electrode including connection with g.i. thimble excavation and re filling as required. 2150 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing as required. 2151 subhead v lightning conductor 2152 providing and fixing of lightning conductor finial, made of 25mm dia 300 mm long, g.i. tube, having single prong at top, with85 mm dia 6 mm thick g.i. base plate including holes etc.complete as required. 2153 jointing copper / g.i. tape (with another copper/ g i tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 2154 fixing of copper/ g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for horizontal run) 2155 fixing of copper/ g.i. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(for vertical run) 2156 providing and fixing testing joint, made of 20 mm x 3 mm thickg.i. strip, 125 mm long, with 4 nos. of g.i. bolts, nuts, chucknuts and spring washers etc. complete as required. 2157 laying copper/ g.i. tape 32 mm x 6 mm from earth electrodedirectly in ground as required 2158 levelling 2159 0.75 boys dormitory 2160 0.25 girls dormitory 2161 guest house 2162 type 3(g+2) 2163 type 3(g+1) 2164 type 4(g) 2165 type 2(g+2) 2166 earth work in excavation by mechanical means (hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. 2167 all kinds of soil 2168 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 2169 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. all work upto plinth level. 2170 1:5:10 (1 cement : 5 coarse sand (zone iii): 10 graded stone aggregate 40 mm nominal size). 2171 c/s for mass concrete 2172 providing and laying 60mm thick faciory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved s;ze, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of engineer in charge. 2173 providing and laying at or near ground level factory made kerb stone of m 25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of engineer in charge (length of finished kerb edging shall be measured for payment). (precast c.c. kerb stone shall be approved by engineer in charge). 2174 excavating trenches upto 1.5 meter depth in all kind ofsoil of required width for pipes. including excavation for sockets and dressing of sides ramming of bottoms including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m or as directed at site by engg in charge. 2175 all kinds of soil 2176 pipes, cables etc, not exceeding 80 mm dia. 2177 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings. this includes jointing of pipes & fittings with one step cpvc solvent cement, trenching, refilling & testing of joints complete as per direction of engineer in charge : external work 2178 external work 2179 25 mm dia nominal bore 2180 for vertical 2181 type 2(g+2) (3x3+5) = 14 meter 2182 type 3(g+2) (3x3+5) = 14 meter 2183 type 3(g+1) (3x2+5) = 11 meter 2184 type iv (3+5) = 8 meter 2185 type guest house (3+5) = 8 meter 2186 32 mm dia nominal bore for horizontal surface 2187 for vertical 2188 boys dormitory (3x3+5)=14 meter 2189 girls dormitory (3x2+5)=11 meter 2190 providing and fixing gun metal non return valve of approved quality (screwed end) : 2191 32 mm nominal bore 2192 horizontal 2193 construction of masonary chamber60x60x75 inside in brickwork cement mortar 1.6 2194 with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 2195 providing and fixing c.i. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (the tail pieces, tapers etc if required will be paid separately) : 2196 50 mm dia 2197 providing and fixing gun metal gate valve with c.i. wheel of approved quality (screwed end) : 2198 25 mm nominal bore 2199 32 mm nominal bore 2200 providing and laying in position cement concreteof specified grade excluding the cost of centering and shuttering (for thrust blocks at bends and junctions of water lines )by 1:2:4 (1 cement : 2 coarse sand : 4 graded stone agg. 20 mm nominal size) 2201 providing and fixing g.i. union in gi pipe including cutting and threading the pipe and making long screws etc. complete(new work) 2202 25 mm nominal bore 2203 32 mm nominal bore 2204 40 mm nominal bore 2205 providing and fixing in position pre cast r.c.c. manhole cover and frame of required shape and approved quality 2206 ld 2.5 2207 rectangular shape 600*450 mm internal dimensions 2208 earth work in excavation by mechanical means (hydraulic excavator) i manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2209 all kinds of soil.0.00 1.50m 2210 extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. 2211 all kinds of soil 2212 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 2213 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 2214 1:5:10 (1 cement : 5 coarse sand (zone iii): 10 graded stone aggregate 40 mm nominal size). 2215 providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement all work up to plinth level: 2216 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) 2217 centering and shuttering including strutting, propping etc. and removal of form for: 2218 foundations, footings, bases of columns, etc. for mass concrete. 2219 walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 2220 suspended floors, roofs, landings, balconies and access platform. 2221 lintels, beams, plinth beams, girders, bressumers and cantilevers. 2222 edges of slabs and breaks in floors and walls. 2223 under 20 cm wide 2224 reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete. 2225 thermo mechanically treated bars. 2226 cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete 2227 40 mm thick with 20 mm nominal size stone aggregate 2228 6 mm cement plaster of mix : 2229 1:3 (1 cement : 3 fine sand) 2230 providing and fixing in position pre cast r.c.c. manhole cover and frame of required shape and approved quality 2231 square shape 450 mm internal dimension 2232 providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per is : 10910 on 12mm dia steel bar conforming to is : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 2233 providing and fixing soil, waste and vent pipes 2234 100 mm dia. 2235 centrifugally cast (spun) iron socketed pipe as per is: 3989. 2236 making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and s.w. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. 2237 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 2238 earth work in excavation by mechanical means (hydraulic excavator) i manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2239 all kinds of soil.0.00 1.50m 2240 earth work in excavation by mechanical means (hydraulic excavator) i manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2241 all kinds of soil.1.50 3.00m 2242 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 2243 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 2244 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size). 2245 providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing andreinforcement all work up to plinth level : 2246 1:1.5:3 (1 cement : 1.5 coarse sand (zone iii): 3 graded stone aggregate 20 mm nominal size) 2247 centering and shuttering including strutting, propping etc. and removal of form for: 2248 foundations, footings, bases of columns, etc. for mass concrete. 2249 walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 2250 suspended floors, roofs, landings, balconies and access platform. 2251 lintels, beams, plinth beams, girders, bressumers and cantilevers. 2252 edges of slabs and breaks in floors and walls. 2253 under 20 cm wide 2254 reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete. 2255 thermo mechanically treated bars. 2256 cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete 2257 40 mm thick with 20 mm nominal size stone aggregate 2258 6 mm cement plaster of mix : 2259 1:3 (1 cement : 3 fine sand) 2260 providing and fixing in position pre cast r.c.c. manhole cover and frame of required shape and approved quality 2261 m d 10 2262 square shape 450 mm internal dimension 2263 providing and fixing soil, waste and vent pipes 2264 100 mm dia. 2265 centrifugally cast (spun) iron socketed pipe as per is: 3989. 2266 making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and s.w. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. 2267 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 2268 excavating trenches of required width for pipes, cable, etcincluding excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.50m including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. 2269 all kinds of soil 2270 pipes cables etc. exceeding 80 mm dia. but not exceeding 300mm dia. 2271 providing and laying non pressure np2 class (light duty) r.c.c. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 2272 150 mm dia. r.c.c. pipe 2273 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 2274 1:5:10 (1 cement : 5 coarse sand (zone iii): 10 graded stone aggregate 40 mm nominal size). 2275 centering and shuttering including strutting, propping etc. and removal of form for : 2276 foundations, footings, bases of columns, etc. for mass concrete. 2277 constructing brick masonry manholein cement mortar 1 : 4 (1 cement : 4 coarse sand) with rcc top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4gradestone aggregate 20mm nominal size); foundation concrete 1:4:8 mix(1 cement : 4 coarse sand : 8 gradedstoneaggregate40 mm nominalsize) insideplastering 12 mm thickwith cementmortar 1:3 (1cement 3 coarse sand ) finished with a floating coat of neat cement and makingchannels incementconcrete 1:2:4 (1cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finishd with a floating coat ofneatcement completeasper standard design 2278 inside size 90 x 80 cm & 45 cmdeep including ci cover with frame (light duty) 455 x 610mm internal dimensions, total weight of cover & frame to be not lessthan 38 kg (weight of cover 23 kg and weight of frame 15 kg) 2279 with common burnt clay f.p.s.(non modular) bricks of classic designation 7.5 2280 inside size 120 x 90 cm & 90 cmdeep including ci cover with frame (medium duty) 560mm internal diameter, total wt. of cover & frame to be not lessthan 208 kg (wt. of cover 108 kg and wt. of frame 100 kg) 2281 with common burnt clay f.p.s.(non modular) bricks of classic designation 7.5 2282 extra for depth for manholes: 2283 size 90 x 80 cm 2284 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 2285 size 120 x 90 cm 2286 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 2287 providing and fixing square mouths. w. gully trapclass sp 1 complete with c.i. gratingbrickmasonry chamber with water tight ci cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 2288 180 x 150 mm. size p type 2289 with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 2290 providing m.s. foot restsorange colour safety footrest 2291 with 20x20 mm square bar 2292 earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2293 all kinds of soil. 2294 filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (40% of item no. 1) 2295 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 2296 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 2297 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size). 2298 brick work with f.p.s. bricks of class designation 75 in foundation and plinth in: 2299 cement mortar 1:6 (1 cement : 6 coarse sand) 2300 12 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 2301 1:4 (1 cement: 4 fine sand) 2302 sub feeder panel 2303 incoming 2304 mccb 200a 35ka tpn 2305 indication light 2306 bus bar feeders 2307 200amp alu.bus bar tpn 2308 out going 2309 g/d phase b mccb 125a 35ka tpn 2310 b/d phase b mccb 125a 35ka tpn 2311 type 3 (g+1) mccb 63a 35ka tpn 2312 type 5 mccb 32a 35ka tpn 2313 guest house mccb 32a 35ka tpn 2314 type 3 (g+2) mccb 63a 35ka tpn 2315 type 2 (g+2) mccb 63a 35ka tpn 2316 spare 2317 emergency section 2318 incoming 2319 mcb 125a 63ka tpn 2320 out going 2321 b/d phase b mcb 63a 35ka dp 2322 g/d phase b mcb 63a 35ka dp 2323 type 3 (g+1) mcb 32a 35ka dp 2324 type 5 mcb 32a 35ka dp 2325 guest house mcb 32a 35ka dp 2326 type 3 (g+2) mccb 32a 35ka dp 2327 type 2 (g+1) mccb 32a 35ka dp 2328 type 2 (g) mccb 32a 35ka dp 2329 spare 2330 enclosure 2331 panel body fabricated in 14/16 swg crca sheet , powder coa ted in siemence grey colour complete in all respects universal gland plates. 2332 boys/girls dormitory panel 2333 incoming 2334 100amp mccb tp 35 ka 2335 indication light r,y,b 2336 bus bar feeders 2337 150amp aluminum bus bar tpn 2338 out going 2339 63amp mcb tpn 10ka 2340 63amp mcb tpn 10ka (spare) 2341 emergency section 2342 incoming 2343 63amp mcb dp 10ka 2344 out going 2345 25amp mcb dp 10ka 2346 32amp mcb dp 10ka 2347 enclosure 2348 1050*1450*150 (17 sft) 2349 panel body fabricated in 14/16 swg crca sheet , powder coa ted in siemence grey colour complete in all respects universal gland plates. 2350 vice principal house panel 2351 incoming 2352 63amp mcb tpn 10ka 2353 indication light r,y,b 2354 bus bar feeders 2355 100amp aluminum bus bar tpn 2356 out going 2357 16 32amp mcb 12sp 10ka 2358 32amp mcb dp 10ka 2359 space for 3 phase meter 2360 emergency section 2361 incoming 2362 32amp mcb dp 10ka 2363 16amp mcb dp 10ka 2364 16amp mcb sp 2365 enclosure 2366 650*500*150 (4sft) 2367 panel body fabricated in 14/16 swg crca sheet , powder coa ted in siemence grey colour complete in all respects universal gland plates. 2368 meter panel (type4/type 2 /type3 /guest house) 2369 incoming 2370 mcb 32a 10 ka tpn 2371 indication light r,y,b 2372 bus bar feeders 2373 100amp alu.bus bar tpn 2374 out going 2375 single phase energy meter 2376 mcb 25a dp 2377 emergency section 2378 incoming 2379 mccb 32a dp 2380 out going 2381 16a dp 2382 enclosure 2383 panel body fabricated in 14/16 swg crca sheet , powder coa ted in siemence grey colour complete in all respects universal gland plates. 2384 supply installation, testing and commissioning of external post top lantern with following and complete as required. 2385 6m high (5.0m above ground) 65mm dia gi pole as approved, adopting socket at top for fixture mentioned below, base plate 300x300x6mm and provision for mounting junction box etc. 1 set 2386 erection of pole in cement concrete 400x400x1000mm deep 1:3:6 ratio cement concrete foundation including excavation , refilling, secured with holding clamps, bolts, nuts, alighnment of poles casting etc. including 100 mm thick lean concrete shall be provided at the bottom. 2387 led type 50 watt (street light) light fittings of all types with allaccessories. 2388 suitable size control box with 1 no. incoming and 2 nos. outgoing terminals and 2 nos. tap out terminal with 1 no.5a hrc fuses complet 1 set 2389 suitable number (s) 40mm dia class b gi pipes(s) from above control box to upto 0.5 meter below ground level for power cable entry. 2390 lt cables 2391 supply of following size of 1.1 kv grade multicore aluminium cunductor pvc sheathed armoured cable as per is 1554. 2392 4 core 25 sqmm 2393 4 core 16 sqmm 2394 3.5 core 240 sqmm 2395 3.5 core 95 sqmm 2396 2 core 50 sqmm 2397 2 core 16 sqmm 2398 2 core 10 sqmm 2399 earthingwithgi earth pipe 4.50 meter long 40mm dia including accessories, and providing masonry enclosure with cover plate having lockingarrangement and watering pipe etc.with charcoal or coke and salt complete as required. 2400 earthingwithgi earth plate 600 x 600 x 3mmthickincluding accessories, and providing masonry enclosure with cover plate having lockingarrangement and watering pipe etc.ith watering pipeof 2.7 meter long etc. with charcoal or coke and salt complete as required. (for mltp & dg body) 2401 providing and fixing 25 mm x 5 mm gi strip in 40 mm dia g.i.pipe from earth electrode, including connection with brass nut bolts , spring washer, excavation and refilling etc, as required ( copper gi plate earthing) 2402 providing& layingearth connection from earth electrode with 6 swg dia giwire in 15 mm gi pipe from earth electrode including connection with gi thimbleexcavation and refilling etc as required. ( for gi pipe earthing ofpoles) 2403 providing and fixing 25mm x 5 mm g.i. strips on surface or in recess for connections etc. as required 2404 providing andfixing mvdanger noticeplate of200 mm x 150 mm madeofmild steelatleast 2 mm thickandvitreousenameled white on both sides & with inscription in signalred colour on front side as required.( on 7mts poles & panels) 2405 lt cables laying 2406 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc/ hume/ metal pipe as required. 2407 upto 35 sq. mm 2408 above 35 sq. mm and upto 95 sq. mm 2409 supplying and laying of following size dwc hdpe pipe isi marked along with all accessories like socket, bend, couplers etc. conforming to is 14930, part ii complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 2410 63 mm dia (od 63 mm & id 51 mm nominal) 2411 120 mm dia (od 120 mm & id 103 mm nominal) 2412 supplying and making end termination with brass comperession gland and aluminium lugs for following size of pvc insulated and pvc sheathed/ xlpe aluminium conductor cable of 1.1 kv grade as required 2413 4 core 25 sqmm 2414 4 core 16 sqmm 2415 3.5 core 240 sqmm 2416 3.5 core 95 sqmm 2417 2 core 50 sqmm 2418 2 core 16 sqmm 2419 2 core 10 sqmm 2420 excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : 2421 ordinary rock 2422 pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. 2423 providing and laying non pressure np2 class (light duty) r.c.c. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 2424 150 mm dia. r.c.c. pipe ...

Building Construction Department - Bihar

42276896 tender for supply of item 5/r to w/s, 5/5, and s/l of pih work in 96 officers flat no. 83/66 at nehru path patna for the year 2023 34 s/f/f water supply and sanitary installation item in toilet and kitchen etc all complete job anglecock (f110004) wall mixture (f2b0022) 15 basin mixture (f110009) two in one bib cock (g4067a1)) two in one angle cock(f100006) over hand shower (f160041) health faucet (f160068) hand shower (f160011) soapdish( f890005) towel ring (f880007) towel rail 600mm long(ace1111n) glass shelf (f880010) corner glass shelf (cw1173) brush holder paper holder (fb80003) bib cock (f110002) connection pipe mirror waste pipe (parryware 3271) cp nipple 40mm dia c.p nipple 50mm dia c.p cap waste coupling providing and fixing stainless steel including painting of fittings and brackets, cutting and making good the walls wherever required dismantling of flushing cistern /wc/a.wc/basin etc cutting holes up to 15x15 cm in r.c.c. iloors sink mixture constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4(1 cement: 4 coarse sand) bottle trap pillar cock rack for bolt we rack for w.b wax seat for w.c s/f/f hand wash hasin s/f/fot pan single pc water closet (hindware 92053) s/f/f 20 mm nominal outer dia pipes s/f/f 25 mm nominal outer dia pipes s/f/f 32 mm nominal outer dia pipes provision for unskilled labour site clearance s/r to w/5, 5/5, and s/i of ph work in 96 officers flat no. 43/23 83/17, 83/28 at nehru pati patna for the year 2023 24 5/f/f water supply and sanitary installation item in toilet and kitchen etc all complete job anglecock (f110004) wall mixture (f280022) basin mixture (f110009) two in one bib cock (g4067a1)) two in one angle cock[f100000) over hand shower(f160041) health faucet (1160068) hand shower (f160011) soapdish(f890005) towel ring (f880007) 75 12 12 12 12 12 12 12 12 12 towel rail 600mm long(ace1111n) glass shelf (f880010) corner glass shelf (cw1173) 12 brush holder paper holder (f880003) bib cock (f110002) 12 counter basin 5 connection pipe 22 mirror 10 waste pipe parryware 3271) 17 c.p nipple 40mm dia 45 c.p nipple 50mm dia waste coupling c.p cap bottle trap s/f/f hand wash basin s/f/f ot pan single pc water closet (hindware 92053) s/f/f comode water tank storage providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. s/f/f 20 mm nominal outer dia pipes s/f/f 25 mm nominal outer dia pipes 200 40 10 10 7 5 7 9 s/f/f 32 mm nominal outer dia pipes 20mm nominal base 25mm dia nominal bore s/f/f nr valves stander make 25mm dia ((h) 25mm dia (v) s/f/f 110 mm dia pvc pipe... s/f/f 110 mm dia pvc bend 9...

Food Corporation Of India - Bihar

41243704 tender for special repair to godowns and ancillaries at fsd buxar; 1 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead . 2 earth work in excavation by machanical means ( hydraulic excavator ) / manual means over areas ( exceedin 30 cm in depth, 1.5 m in widthas well as 10 sqm on plan including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by engineer in charge. 3 preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re rolling the sub grade and disposal of surplus earth lead upto 50 metres. only consolidation of sub grade etc. 4 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level 1:4:8 ( 1 cement : 4 sand ( zone iii ) direved from natural sources : 8 graded stone aggrgate 40 mm nominal size derived from natural sources ) 5 brick work with common burnt clay f.p.s. ( non modular ) bricks class designation 7.5 in foundation and plinth in : cement mortar 1:6 ( 1 cement : 6 coarse sand ) . 6 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level :1:2:4 ( 1 cement: 2 coarse sand ( zone iii ) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources ) 7 making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 manufactured sand derived from recycled concrete aggregate ( rca ) : 6 graded stone aggregate 20 mm nominal size ( recycled concrete aggregate ( rca ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth 8 demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. 9 providing and laying brick tiles on roofs jointed with cement mortar 1:4 ( 1 cement : 4 coarse sand ) mixed with 2% integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) and finished neat complete. with available brick tiles. 10 providing and laying brick tiles on roofs jointed with cement mortar 1:4 ( 1 cement : 4 coarse sand ) mixed with 2% integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) and finished neat complete. with new brick tiles. 11 half brick masonry with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 in superstructure above plinth level up to floor v level : cement mortar 1:4 ( 1 cement :4 coarse sand ) 12 providing gola 75 x 75 mm in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge ) , including finishing with cement mortar 1:3 ( 1 cement : 3 fine sand ) as per standard desing : in 75 x 75 mm deep chase. 13 brick work with common burnt clay f.p.s. ( non modular ) bricks class designation 7.5 in superstructure above plinth upto floor v level in all shapes and sizes: cement mortar 1:6 ( 1 cement : 6 coarse sand ) . 14 12 mm cement plaster of mix :1:6 ( 1 cement: 6 coarse sand ) 15 15 mm cement plaster on rough side of single or half brick wallof mix 1:6 ( 1 cement : 6 coarse sand ) 16 20 mm cement plaster of mix :1:6 ( 1 cement: 6 fine sand ) 17 taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutter to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the engineer in charge. 18 dismantling tile work in walls laid in cement mortar including stacking material within 50 metres lead. for thickness of tiles 10 mm to 25 mm 19 dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.for thickness of tiles 10 mm to 25 mm 20 dismantling w.c. pan of all sizes including disposal of dismantled materials i / c malba all complete as per directions of engineer in charge 21 hacking of cc flooring including cleaning for surface etc. complete as per direction of the engineer in charge. 22 chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 ( 1cement : 4 coarse sand ) . medium shade pigment using 50% white cement 50% grey cementremoving white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete 23 providing and laying vitrified floor tiles in different sizes ( thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including grouting the joints with white cement and matching pigments etc., complete.size of tile 600x600 mm 24 providing and laying vitrified tiles in different sizes ( thickness to be specified by manufacturer ) , with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 ( 1 cement: 3 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including grouting the joint with white cement & matching pigments etc. complete 25 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) , of 1st quality conforming to is : 15622, of approved make, in all colours, shades, except white, ivory, grey, fume red brown, laid on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sq.m including pointing the joints with white cement and matching pigments etc., complete: toilet block. 26 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 27 demolishing cement concrete manually / by mechanical means including disposal of material within 50 meter lead as pe direction of engineer in charge : nominal concrete 1:3:6 or risher mix ( i / c equivalent desing mix ) 28 cement concrete flooring 1:2:4 ( 1 cement: 2 coarse sand : 4 graded stone aggregate ) finished with a floating coat of neat cement including cement slurry etc., but excluding the cost of nosing of steps etc. complete. 50mm thick with 20mm nominal size stone aggregate. 29 renewing glass panes, with putty and nails wherever necessary including racking out the old putty: float glass panes of nominal thickness 4 mm ( weight not less than 10kg / sqm ) 30 providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) : 31 for shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of epdm rubber / neoprene gasket required ( fittings shall be paid for separately ) anodised aluminium ( anodised transparent or dyed to required shade according to is: 1868, minimum anodic coating of grade ac 15 ) 32 providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5.0 mm thickness ( weight not less than 10 kg / sqm ) 33 providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete. powder coated minimum thickness 50 micron aluminium. 34 providing and fixing aluminium extruded section body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm ) , with double speed adjustment with necessary accessories and screws etc. complete. 35 removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete 36 white washing with lime to give an even shade :old work ( one or more coats ) 37 finishing walls with water proofing cement paint of required shade :old work ( one or more coats @ 2.20 kg / 10 sqm ) complete. 38 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 39 finishing walls with acrylic smooth exterior paint of required shade : new work ( two or more coat applied @ 1.67 ltr / 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm ) . 40 applying priming coats with primer of approved brand and manufacture, having low voc ( volatile organic compound ) content.with ready mixed pink or grey primer on wood work ( hard and soft wood ) having voc content less than 50 grams / litre 41 wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :two or more coats on new work 42 painting with synthetic enamel paint of approved brand and manufacture of required colour to give and even shade one or more coats on old work. 43 cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial desilting of manholes and dechocking of sewer lines. dechocking and flushing of sewer line from one manhole to another 44 cleaning of terrace / loft water storage tank ( inside surface area ) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of engineer in charge. ( the old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ rs. 0.10 per litre ) ( if during cleaning any gi fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account ) 45 providing and fixing water closet squatting pan ( indian type w.c. pan ) with 100 mm sand cast iron p or s trap, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests. 46 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: w.c. pan with isi marked white solid plastic seat and lid. 47 providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and c.p. brass spreaders with brass unions and g.i clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :one urinal basin with 5 litre white p.v.c. automatic flushing cistern 48 providing and fixing wash basin with c.i. brackets, 15 mm c.p. brass pillar taps, 32 mm c.p. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: white vitreous china flat back wash basin size 550x 400 mm with single 15 mm c.p. brass pillar tap 49 providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fitting. 50 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge. 51 providing and fixing p.v.c. waste pipe for sink or wash basin including p.v.c. waste fittings complete :flexible pipe : 32 mm dia 52 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. 53 providing and fixing ptmt towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. 54 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : 55 providing and placing on terrace ( at all floor levels ) polyethylene water storage tank, is : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 56 providing and fixing ptmt ball cock of approved quality, colour and make complete with epoxy coated aluminium rod with l.p. / h.p.h.d. plastic ball. 20 mm nominal bore, 120 mm long, weighing not less than 198 gms. 57 providing and fixing c.p. brass bib cock of approved quality conforming to is:8931 :15 mm nominal bore 58 providing and fixing c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931 : 15 mm nominal bore. 59 providing and fixing uplasticised pvc connection pipe with brass unions : 45 cm length: 15 mm nominal bore 60 providing and fixing ptmt grating of approved quality and colour. circular type : 125 mm nominal dia with 25 mm waste hole. 61 providing and fixing chlorinated polyvinyl chloride ( cpvc ) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i / c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. : 20 mm nominal dia pipes. 62 providing and fixing chlorinated polyvinyl chloride ( cpvc ) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, i / c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. : 15 mm nominal dia pipes. 63 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion, ( i ) single socketed pipes : 110 mm diameter 64 providing and fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion: single tee without door : 110x110x110 mm 65 providing and fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion: coupler : 110 mm 66 providing and fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion: bend 87.5 degree: 110 mm bend 67 providing and fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382, leaving 10 mm gap for thermal expansion: shoe ( plain ) : 110 mm shoe 68 providing and fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with m.s. screws of required length, including cutting brick work and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand ) and makinggood the wall etc. complete : 110 mm 69 providing and laying polished granite stone flooring inrequired design and pattern, in linearas wellas curvillinearportionsof building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thickness base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by engineer in charge. polshed granite stone slab colour of black, cherry / ruby red orequivalent. 70 providing and fixing stainless steel ( grade 304 ) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature ( wherever required ) and fitting the same with necessary stainless steel nuts and bolts complete, i / c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of engineer in charge, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc. ) ....

Military Engineer Services - Bihar

40135204 tender for special repair to bldg no p 86 at ota gaya; 1 demolition of cement concrete ( unreinforced ) in ground floors and pavings n exc 15 cm thickness ( below or above ground level ) . 2 demolition of brickwork or stone / boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. 3 taking down cement plaster on brick or stone walls etc, including racking out joints, hacking for key, scrubbing down with water etc. 4 dismantling floor, hearth or wall tilling including cement mortar bedding , removing serviceable tiles to store and rubbish off the premises. 5 taking down chowkat or frame with shutter ( without taking off shutters from the frames ) areaexceeding 1.5 sq mtr but not exceeding 4 sq mtr each 6 taking down chowkhats or frames not exc. 1.5 sq. m each but with shutters ( without taking off shutters from the frames ) . 7 dismantling water tanks of capacity exc 500 & not exc 1000 litres and removing to store. 8 taking up or down 15mm dia bore steel tubing and connections, including cleaning for refixing or removal to store. 9 taking up or down 20mm dia bore steel tubing and connections, including cleaning for refixing or removal to store. 10 dismantling of asbestos cement ( corrugated, semicorrugated, etc. ) sheets in roof coverings complete. 11 dismantling wrought iron or mild steel work of any description not otherwise provided for complete. 12 taking down eaves gutters and rainwater pipes ( any size or pattern ) , including all fittings, heads, shoes, bends, swan necks, etc., including cleaning or refixing or removal to store ( measured overall as fixed along the centre line over fittings and accessories ) 13 m & l for providing 75 mm thick pcc type c 1, 1 : 3 : 6, ( using 40 mm graded aggregate ) as sub base flooringand finishing surfaces even and smooth without using extra cement complete. 14 m & l for providing 50 mm thick pcc type c 2, 1 : 3 : 6, ( using 40 mm graded aggregate ) as inplinth protection and drain bed complete all as specified and directed. 15 m & l for providing precast cement concrete 1:2:4 type b 1 using 20mm graded stone aggregate as in landings, cover slabs ( for man holes etc ) and similar work including necessary formwork and set in cement mortar 1:6complete all as specified and directed. 16 m&l for brick work using sub class b old bricks straightor curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed. 17 m&l for brick work using sub class b old bricks ( except bricks ) straightor curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed. 18 m & l for 10 mm thick rendering in cement mortar 1:6 on fair faces of brick work or concrete surfaces and finishing the surface even and smoth without using extra cement complete all as specified and directed. note : chicken wire mesh be provided to the joints of column and beams during rendering. 19 m & l for rendering 15mm thick in two layerson external surfaces on brick / concrete surfaces in cm 1:4 finished even and smooth without using extra cement with wpc. note : wpc measured and paid separatly andchicken wire mesh be provided to the joints of column and beams during rendering. 20 m & l for rendering 10mm thick internal surfaces on fair faces of brick or concrete surfaces in cement plaster 1:3 as in ceiling and finished even and smooth ( without using extra cement ) complete. 21 supply only liquid water proofing compound ( make : sika latex power ) 22 cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with finishing with cement mortar 1:3. 23 m & l for non skid ceramic coloured tiles 7 to 8 mm thick ( square / rectangular ) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in cm 1:4 complete all as specified and directed. 24 m & l for coloured glazed ceramic tiles in vertical surface 450x300x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10 mm thick screed bed in cm 1:3 complete all as specified and directed. 25 m & l for machine pressed chequered cement concrete tiles 30cm x 30cm x 30mm thick with grey cement and pigment over 20 mm thick screed bed in cement mortar 1:4 complete all as specified and directed. 26 m & l for machine pressed precast concrete interlocking paver block any shape and size confirming to is 15658 2006 of 60 mm thickness, m 35 grade with grey cement and pigment complete all as specified and directed. 27 sand filling under floors for cushioning including watering and consolidation complete all as specified and directed. 28 m & l for 25mm thick cement concrete type b 0, 1:2:4using 12.50mm graded stone aggregate as in levelling course complete all as specified and directed. 29 m & l for providing pcc type b1, 1 : 2 : 4, ( using 20 mm graded aggregate ) as incoping, and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed. 30 s & f rolled mild steel in joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. ( cut to ordinary lengths i.e. within 20mm of the length indicated ) confirming to fe 410 w ( gde e 250 ) quality a complete. 31 s & f pre painted galvatume aluminum zinc coating gi based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 mpa as in roof covering / cladding to wall, fixed with self tapping screws as specified. 32 s & f solid pvc frame of size 50 mm x 47 mm made out of 5 mm single side prelam pvc sheet & edges will be printed to match with prelam sheet rein forced with ms square tube etc. 33 s & f factory made solid panel pvc door shutter 30mm ( style ) consisting of frame made out of m.s tubes for top and bottom rails m.s frame shall be covered with heat moulded plain colour pvc c channel having a pvc sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour pvc sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour pvc sheets to be fitted in the m.s frame welded / sealed to the stiles and rails with suitable pvc sheet beading and joined together with solvent cement, supplying and fixing in the frame 34 s & f powder coated aluminium section for doors, windows, ventilators sliding / openable etc with joining cleat for fixing, locking arrangement, rubber beading, screws, etc including taking down and making the surface good complete all as specified.make : jindal / hindalco / indalco. note : ( i ) glazing and wire mesh shall be measured and paid separetely. ( ii ) item shall be paid as per weight of aluminium section ( iii ) the rate quoted shall be inclusive of the cost of neoprene beading, glazing pin, screws and powder coated fittings such as locking arraangement etc as required, which shall not be measured for arriving the weight ( iv ) the rate shall also be inclusive of complete packing with silicon gel around contacting surfaces of aluminium work, and including matching the existing. 35 s & f framed work such as grills, gratings, etc.. with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to fe.290.gde e 165 complete all as specified and directed. 36 taking down existing aluminium door or window shutter with frame area exceeding 1 sqm and re fixing in same opening after repair / replace the defective jointing cleats / screws and fittings etc all as per specified and directed by engr in charge. 37 s&f 100 mm long stainless steel butt hinges with steel hinge pin etc. 38 s&f 150 mm long aluminium anodised, barrel tower bolts of extruded section and 12 mm dia fixed. 39 s&f 150mm long aluminium anodised handle cast type and fixed d type 40 s&f250mm long aluminium alloy, anodised, sliding door bolt with hasp, staple ( bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixedcomplete all as specified. 41 s&f white colour rotational three layer moulded polyethylene water storage tanks ( cylinderical vertical with closed top ) capacity 1000 ltrhoisted and fixed in position all as specified and directed. make; sintex / rotex / polycon 42 s & f in repair 25mm dia bore ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed. 43 s & f in repair 25mm dia bore cpvc gate valves with handle or wheel head, screwed both ends for pipe and fixed. 44 s & f in repair 20mm dia bore cpvc gate valves with handle or wheel head, screwed both ends for pipe and fixed. 45 supplying and laying of cpvc pipes 25mm outer dia sdr 11 & plain cpvc sdr 11 including all fittings on walls / ceilings or in floors including necessary cutting / chasing of walls and floors complete all as specified and directed. 46 s & f 25mm bore male brass threaded adaptor ( mta / mbta ) or female brass threaded adaptor ( fta / fbta ) complete. 47 supplying and laying of cpvc pipes 20mm outer dia sdr 11 & plain cpvc sdr 11 including all fittings on walls / ceilings or in floors including necessary cutting / chasing of walls and floors complete all as specified and directed. 48 s & f 20mm bore male brass threaded adaptor ( mta / mbta ) or female brass threaded adaptor ( fta / fbta ) complete. 49 s & f 110mm bore pvc ( swr ) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors and connecting with manholes or disposal place. 50 s & f 110mm dia borepvc ( swr ) bends with access door all as specified and as directed. 51 s & f of pvc ( swr ) junction single, ( single t ) 110 mm bore equal or unequal with acess door complete. 52 s & f 110mm bore pvc ( swr ) vent cowl with rubber ring joints, fixed to pipes all as specified. 53 s & f 75mm bore pvc ( swr ) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors and connecting with manholes or disposal place. 54 s & f 75mm dia borepvc ( swr ) bends with access door all as specified and as directed. 55 s & f of pvc ( swr ) junction single, ( single t ) 75 mm bore equal or unequal with acess door complete. 56 s & f as in repair of vitreous china squatting pan, ‘orissa’ pattern, size 580 x 440 mm white, with integral foot rests water closet ( squatt pattern ) complete including provision of lime concrete bedding complete all as specified and as directed make : hindware / parryware / cera 57 s & f in repair 10 litre capacity pvc valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete. 58 s & f in repair vitreous china wash basin, white, flat back of size 550x400mmexcluding taps, waste, chain and plug and porcelain stopper but including brackets, cutting for and pinning in ends of brackets or erecting stand and inclusive of fixing of supply and waste pipe and 32mm dia chromium plated waste fittings with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed. ( make parryware / hindware / jaquar ) 59 s & f pvc connections 15mm size with ptmt nuts of length 600mm complete. 60 s & f in repair 6mm thick looking mirror of 1st quality glass, mounted on 6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete. ( saint gobain / modifloat ) 61 s & f in repair 15 mm dia bore fancy type chromium plated bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed. 62 s & f in repair 15 mm dia bore fancy type chromium plated two way bib taps, cast copper alloy with crutch or butterfly handle screwed down, high pressure, screwed both ends for iron pipe or for unions. 63 s & f in repair 15 mm dia bore fancy type chromium plated stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed. 64 supply & fix in repair brass chromium plated pillar tap swan neck long body fancy typefor wash hand basin for mixing hot and cold water screwed down for iron pipes suitable for 15mm bore pipe complete. 65 s & f in repair brass / chromium plated tubular towel rail, 20mm dia, d type, 60cm long between flanges complete. 66 s & f in repair soap dish, any type, fixed to plugs with chromium plated brass screws complete. 67 s & f in repair 125mm dia stainless steel grating ( double q ) fixed on floor trap / nahani trap in cement mortar 1:6, all as specified and directed. 68 supply & fix in repair brass chromium plated wall mixer ( 2 / 3 hole ) with provision for connection to shower rose for mixing hot and cold water screwed down for iron pipes suitable for 15mm bore pipe complete all as specified and directed. ( make parryware / prayag / hindware ) 69 s & f in repair chromium plated shower rose 15 mm size, 125mm long with 300 mm arms including fixing to pipe or union complete. ( make : jaguar / parryware / hindware ) 70 s & f in repair harrison rails ofbore 20 25mm , mild steel, chromium plated cut to length as required and fixing with brackets, stops, rollers, finiales etc complete all as specified and directed. 71 m & l for 2 mm thick of birlawhite putty / jk white wall care putty in two coats on new / old plastered surfaces and making the surface uniform & smooth on walls / ceilings. 72 m & l for preparing new plastered wall surfaces and distempering two coats on walls with distemper oil emulsion, white or tinted over a coat of chalk whiting complete all as specified and directed. 73 m & l for preparing new plastered ceiling surfaces and distempering two coats on ceilings with distemper oil emulsion, white or tinted over a coat of chalk whiting complete all as specified and directed. 74 m & l for preparation of old plasteredsurfaces and applying one coat of acrylic distemper on walls complete all as specified and as directed. 75 m & l for preparation of old plasteredsurfaces and applying one coat of acrylic distemper in ceilings complete all as specified and as directed. 76 m & l for one coat of exterior emulsion paint white or tinted on walls of fascia of roof or chajjas on old decorated prepared plastered / painted surfaces of bldg all as specified and directed. make : asian paints ( brand ace ) / berger paint ( brand walmasta ) / nerolac paint ( suraksha plus ) . 77 m & l for two coats of exterior emulsion paint white or tinted over a coat of primer on walls of fascia of roof or chajjas on new prepared plastered surfaces of bldg all as specified and directed. make : asian paints ( brand ace ) / berger paint ( brand walmasta ) / nerolac paint ( suraksha plus ) . 78 m & l for one coat of exterior weather proof emulsion paint tinted on walls of fascia of roof or chajjas on old painted surfaces brick, stone, concrete, asbestos cement or plaster on old decorated prepared plastered / painted surfaces of bldg all as specified and directed. make : asian paints ( apex ) / berger paint ( brand weathercoat smooth ) / nerolac paint ( nerolac ) . 79 m & l two coat of syntetic enamel paint overnewsteel surface of any description over 10cm in width or grithnot otherwise describedover one coat red oxide primerincl preparation of surfaces complete. 80 s&f 4mm thick sheet glass, ordinary quality and glazing with oil putty in a square n exc 0.5 sq m in each pane. 81 s & f of 4.00 mm thick figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete. 82 s & fstainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40mm and fixed with beeding / staples complete all as specified and directed. 83 m&l for providing water proofing treatment over cleaned roof surface with super thermo app modified polymeric membrane comprising of followings : ( i ) . complete removal of existing roof treatment by picking, sweeping clean and washing down with water to remove dust etc from plastered / roof surface / walls and filling the crackes with sealing compound grade a . ( ii ) rendering / screed bed 15 mm thick in cement mortor ( 1:4 ) mixed with liquid water proofing compound as per manufacturers instructions andfinished the surface fair and even. ( iii ) applying evenly a coat of bitumen based primer conforming to is 3384 1965 @ 0.30 kg / sqm. ( iv ) applying 3 mm thick app modified polymeric membrane with non polyster reinforcement of approved make, weight not less than 3.50 kg / sqm laid with gas torch and fastedon roof surface with roller. the over laps 100mm and shall be sealed by torch application as per manufacture instructions including vertical surfaces after cutting necessary grooving and making good with pcc 1:2:4 type b o with sika latex power as per manufacture instructions. ( v ) applying two coats of bituminous anticorrosive multi purposealuminium coating ( super silver shield ) @ 150 gm / sqm per coat over polymeric membrene. note : wpc shall be measured and paid separately. 84 m&l for conventional rcc septic tank designed to carry sewage and sullage water, excavation in any type of soil, pcc 1:4:8 below foundation, rcc m 30 design mix in walls, base slab, baffle walls and roof slab including beams etc with vent shaft, manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter for 50 users. 85 soakage wells exc, in ordinary soil, foundation in pcc 1:3:6 wells of honey combed and solid in m 25 concrete , incl interlocking chamber, screen chamber brick work in cm, rcc cover slab in m 25 / rr masonary / filling with brick bats, complete of size 2.4 dia x 3.00 m deep. 86 taking down copper / aluminium point wiring ( light, fan, bell, socketor power ) complete including fixture and fittings such as switches, ceiling roses, pendent, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit ( credit a for above items should be made as per condition seperately ) and making good distrubed surfaces ofwalls, floors etc complete all as specified and directed at site. 87 taking down old / unserviceable distribution board by disconnection of electric connection carefully spn dbs / tpn dbs / main switch including old unserviceable mccbs / mcbs, isolators, etc and making good to disturbed surface complete all as specified and directed. 88 taking down carefully copper / aluminium sub main wiring of any size fromsurface / concealed / existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed. 89 taking down ceiling fan / exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan bladesand deposit to mes store yard of age e / m complete all as specified and as directed. 90 m&l for point wiring with 1.5 sq mm single core pvc insulated unsheathed copper frls multi stranded conductor cable in andincluding concealed pvc conduit of size 20 / 25mm isi marked inclusive oftees, bend, elbows etc upto and including sunk in anodized pressed steel box for housing switch socket etc withwhite laminated 3 mm thick hylam sheet cover isi marked of suitable size complete including pvc insulated multi strandedcopper conductor 1.5 sq mm frls cable as earth wire to common earth dolly for connection to ceiling rose to earth terminalincludingcutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed by engr in charge for following : 91 ( a ) one light point controlled by one, one way switch 5 amps 92 ( b ) one fan point / exhaust fan point controlled by one, one way switch 5 amps and regulator 93 ( c ) one 3 point 5 amps switch socket outlet point controlled by one switch on the same board. 94 ( d ) one 3 pin 5 amps switch socket outlet point controlled by one switch on independent board. 95 description all as per item no 90 here in before butusing 2.5 sq mm single core copper conductor cable of multistranded flame retardant pvc insulated unsheathed 1100 volts grade for 5 / 15 amps switch socket cobmination point including necessary running of2.5 sq mm copper conductor flame retardant pvc wire as earth continuity conductor along with wiring and connecting to the common eath dolly. 96 s & f switch piano type single pole 5 amp, 230 volts complete all as specified and directed. 97 s & f switch piano type single pole 15 amp, 230 volts complete all as specified and directed. 98 s & f socket outlet 2 in 1, 5 pin, 5 amp, 230 volts complete all as specified and directed. 99 s & f socket outlet 2 in 1, 5 pin, 5 / 15 amp, 230 volts complete all as specified and directed. 100 s & f ceiling rose, surface bakelite with 3 terminals, isimarked for batten fitting complete. 101 s & f stepped type electronic fan regulator flushtype complete all as specified and directed. 102 s & f lamp holder, pvc / polycarbonate type with back plate suitabl for batten / slanting fittings complete all as specified and directed. 103 m & l for sub main wiring with approved colour coding as per is with two single core pvc insulated frls cable with stranded copper conductor of size 6 sq mm nominal area and drawing into suitable size of pvc non metallic rigid heavy duty pvc conduit of white / ivory colour and its accessaries isi marked heavy duty of suitable sizeincluding concealed in wall etcone run of pvc insulated with 6.0 sqmm ( nominal area ) stranded copper conductor frls cable as earth wire complete all as specified and as directed. note: two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of pvc conduit will be measured as one unit 104 s & f for sheet metal enclosure mcb db tpn 4 way vertical type with 200 amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the dbs in wall by cutting the brick / stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. 105 s & f for sheet metal enclosure mcb db spn 8 way with 200 amps rated bus bar 240 volts double door with magnetic locking system including necessary provision for inserting the dbs in wall by cutting the brick / stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. 106 s & f formcb tripple pole and neutral rated capacity 63 amps, 415 volts breaking capacity 10 ka, c curve complete all as specified and as directed. 107 s & f for mcb single pole and neutral rated capacity 32 amps, 240 volts breaking capacity 10 ka, c curve complete all as specified and as directed. 108 s & ffor mcb single pole rated capacity 5 to 32 amps, 240 volts breaking capacity 10 ka, c curve complete all as specified and as directed. 109 s & f for ceiling fan, 230 volts, 1200 mm sweep with service value of the fan shall be greater than 6.1 as per bis with necessary accessories and electrical connections from ceiling rose to fan teriminal complete all as specified and as directed. 110 s & f for highly efficient led bulbs, 10 w, used as a ready replacement for existing gls / cfl direct fit lamp, in b 22 cap of make bajaj, havells, hpl complete all as specified and directed 111 s & f forled 10 watts batten aluminium extruded with decorative end caps complete all as specified and as directed. make bajaj cat part no bclsb 10 nw or its equivallent model in wipro, philips. 112 s & f for wall mounted led tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouputboxtype fitting, 230 volts and intregrated electronic driverconnector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired andnecessary mounting arrangements, provision of new 3 core multistrandedcopper conductor of size 23 / 0.193 from ceiling rose to fitting complete all as specified and as directed. 113 s & f building security lightfitting 1 x 35 / 36 w led new generation energy saving & environmental friendly long life led street / bldg security light made up of pressure die cast aluminium housing with mid power led as lighting source and pc cover having top opening including driver compartment driver with ip66 protection and impact resistance of ik07 including with suitable for 32mm dia medium grade g i bracket not exc 1.5 mtr length made to shape & fixing on pole / wall with 2 nos of ms clamp including necessary connection from lt oh line / buildings 114 s & f for energy efficient exhaust fan of 230 mm sweep made of metal body ventil air ds type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of pvc flexible copper cable of size 23 / 0.0076 two core from ceiling rose to exhaust fan forconnection and making suitable size ofhole to existing brick wall for fan basecompelte all as specifiedand directed. ( note : cost of suitable opening wall for fixing exhaust fan is deemed to be includedin overall rate quoted ) . 115 taking down existing old extg unserviceable lt ug / service cable of any description and sizecomplete all as specified and directed. 116 supply & laying in trenches / laid in floor / duct / drawn through conduitxlpe insulated, armoured, heavy duty elecric cable with alluminium conductor, 1100 volt grade cross sectional area 25 sqmm 4 core. 117 excavation in trenches not exceeding 1.5 mtrs wide & not exceeding 1.5 mtr in depth in soft or loose soil & getting out complete all as per & directed. 118 returning filling including spreading levelling watering & well ramming in layers not exc 25 cm 119 removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as directed. 120 m & l for laying of hdpe double wall corrugated pipes in trench for ug cable protection conforming to is 14930 part ii with ip 67 having outer dia 50 mm and inner dia of 38 mm including necessary fittings such as couplers, bends etc complete all as specified and directed. make: rex / rudrax polymers / finolex 121 m & l for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically ( earth pit not less than 2.25m deep below ground level ) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to gi earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia. medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, pcc chamber, ci frame and cover, ms funnel with wire mesh all as shown in electrical plate no 3 of ssr part i including excavation and earthwork in any type ofsoil / strata and testing on completion. note: gi earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted....

Ministry Of Power - Bihar

39704208 bids are invited for solvent cement cpvc pipe ftng astm f493 (q3) , primer cpvc pipe ftng astm f 656 (q3) total quantity : 200...

Reserve Bank Of India - Bihar

38467551 dismantling work carefully dismantling of mosaic skirting with backing mortar of entire flat, kota stone flooring in bathroom, wc , skirting ceramic dado tiling kitchen, bathroom and toilets a flooring of all areas of entire flat and removal of malba / debris from the site as per local by laws. etc . please refer sl.no.1 of tender part ii of price bid for full description. 2 2 dismantling work providing and constructing half brick masonry wall wherever required by using locally available 1st class bricks for partitions in in cement, mortar 1:4 ( 1 cement :4 coarse sand ) at all heights of the existing building block with provision of 6mm two bars at every third course of the brick wall in proper line & level. rates are inclusive of provision of ms bar, scaffolding, curing, all to be completed as directed by bank?s authority. please refer sl.no.2 of tender part ii of price bid for full description 3 3 dismantling work providing and applying internal cement plaster 1:4 of the thickness 15 mm ( average ) including raking the joints, scaffolding, curing etc.; where ever required. all to be completed as directed by the bank?s authority. please refer sl.no.3 of tender part ii of price bid for full description 4 4 dismantling work providing and applying polymer based two compound water proofing treatment to the sunken portion of the toilets, baths etc. by using products of m / s pidilite, m / s fosroc, m / s sika, m / s basf, or any other equivalent approved make . please refer sl.no.4 of tender part ii of price bid for full description 5 5 dismantling work providing and laying brick bat coba to the sunken floors using best quality locally available well burnt sliced bricks in cement mortar 1 : 4 ( i cement : 4 coarse sand ) mixed with water proofing compound as per manufacturers specifications, roughening the top layer of cement mortar / top surface of sunk filling with broom to receive the flooring. please refer sl.no.5 of tender part ii of price bid for full description 6 6 dismantling work providing and laying in position plain cement concrete with nominal mix 1 :2 :4 ( 1 cement :2 coarse sand :4 hard stone aggregate 20 mm and down grade ) for any kind of work including cost of material, labour, shuttering, curing, etc. complete. please refer sl.no.6 of tender part ii of price bid for full description 7 7 dismantling work providing & fixing 18 20mm thick mirror polished z black granite slab of approved quality over the modular kitchen platform with necessary best in class adhesive including mirror polished molding of exposed edges etc. complete as per direction. the rate shall include making hole for gas pipe, necessary pasting chemicals & adhesive etc. basic rate of granite ? rs. 230 / sft excluding gst. please refer sl.no.7 of tender part ii of price bid for full description 8 8 dismantling work providing and fixing factory made approved make single extruded wpc ( wood polymer composite ) solid extruded door frames / chowkhat comprising of virgin pvc polymer, calcium carbonate and natural fibers ( wood powder / rice husk / wheat husk ) and non toxic additives fabricated with miter joints after applying pvc solvent cement and screwed with full body threaded star headed ss screws having minimum frame density of 750 kg / cum. please refer sl.no.8 of tender part ii of price bid for full description 9 9 dismantling work providing and fixing factory made approved make & model single extruded wpc ( wood polymer composite ) solid plain flush door shutter ( may be single or double leaf as per requirement ) of required size comprising of virgin polymer, calcium carbonate and natural fibers ( wood powder / rice husk / wheat husk ) and nontoxic additives having minimum density of 650 kg / cum and adequate screw withdrawal strength . please refer sl.no.9 of tender part ii of price bid for full description 10 10 dismantling work removing of door shutters from its position and re fixing the same in suitable place after minor repairing with replacement of m.s. hinges of existing type as directed by banks engineer.please refer sl.no.10 of tender part ii of price bid for full description 11 11 dismantling work decorative curtain rod: providing, supplying and fixing the decorative curtain rods of approved finished material, make & shade etc., all to be completed as directed by the bank?s engineer. basic price 250 / rft without gst.please refer sl.no.11 of tender part ii of price bid for full description 12 12 dismantling work providing and fixing anodized aluminium louvered windows / ventilator system having provision of exhaust fan ( where ever needed ) in washroom: providing fixing powder coated aluminum ventilator shutter & partition with epdm rubber / neoprene gasket with float glass pane of 4.0mm thick.please refer sl.no.12 of tender part ii of price bid for full description 13 13 dismantling work providing and laying approved size 450mmx300mm, 300 x 600 or any other size approved 1st quality coloured / white ceramic tiles of approved make ( rak, somany, johnson, nitco, kajaria ) and finish in dado work laid on average 12 mm thick cement mortar 1:3 ( 1cement: 3 coarse sand ) bedding set in cement slurry.please refer sl.no.13 of tender part ii of price bid for full description 14 14 dismantling work washroom flooring :supplying and laying approved size first quality approved make ( rak, somany, johnson, nitco, kajaria, shade, finish and size, white / coloured ceramic non skid tiles in flooring, laid to desired level, slope and pattern, on 20mm thick cement mortar 1:4 ( 1 cement: 4 coarse sand ) bedding set in cement slurry.please refer sl.no.14 of tender part ii of price bid for full description 15 15 dismantling work providing and laying double charged vitrified tiles of approved size, approved manufacture such as ( rak, somany, johnson, nitco, kajaria, or any other equivalent approved make and shade in flooring and skirting, inlays, boarders, etc. of required width in required design, shape and pattern on existing flooring laid.please refer sl.no.15 of tender part ii of price bid for full description 16 16a repairing work providing and fixing in position medium quality tata make gi pipe with approved heavy quality / isi mark gi fittings and specials, ms hooks, etc. for concealed as well as exposed piping work including threading, jointing and testing of pipe line, providing & applying a coat of approved quality metal primer, wrapping the concealed piping 15mm diameter pipe . please refer sl.no.16a of tender part ii of price bid for full description 17 16b repairing work providing and fixing in position medium quality tata make gi pipe with approved heavy quality / isi mark gi fittings and specials, ms hooks, etc. for concealed as well as exposed piping work including threading, jointing and testing of pipe line, providing & applying a coat of approved quality metal primer, wrapping the concealed piping 20mm diameter pipe . please refer sl.no.16b of tender part ii of price bid for full description 18 17a repairing work providing and fixing in place heavy duty pvc pipes and waste pipes of approved make and equivalent specification of isi marked with m.s. clamps including all junctions, bends, tees, offsets etc. with leak proof joints as per manufacturers specifications 50mm diameter . please refer sl.no.17a of tender part ii of price bid for full description 19 17b repairing work providing and fixing in place heavy duty pvc pipes and waste pipes of approved make and equivalent specification of isi marked with m.s. clamps including all junctions, bends, tees, offsets etc. with leak proof joints as per manufacturers specifications 75 100mm diameter . please refer sl.no.17b of tender part ii of price bid for full description 20 18 repairing work providing and fixing new net lon jalli in radium print of tufflex make in proper size, line and level or approved equivalent over windows with necessary velcro, nails etc as directed. the net lon jalli should be fixed over 40mmx4omm sal wood frame with necessary enamel paint over a coat of wood primer . please refer sl.no.18 of tender part ii of price bid for full description 21 19 repairing work providing & fixing pedestal type wash basin of hindware or approved quality having size 55cm x 40cm including providing fixing c.p. brass pillar cock mixer type ( heavy type ) , angular stop cocks, pvc connector pipes 15mm dia, pvc waste pipe 32mm, c.p. waste and pvc waste line of 50mm c.p. waste and pvc waste line of 50mm dia. up to the floor trap all of approved quality, filling the joints with white cement by adding pigment of matching shade etc. complete as directed by banks engineer. please refer sl.no.19 of tender part ii of price bid for full description 22 20 repairing work providing and fixing heavy quality 80mm dia nahani trap with stainless steel grating of suitable size including making connection up to waste line with cement and necessary water proofing compound as per manufacturer?s specification etc. including repairing the floor etc .as per existing adjoining finish . please refer sl.no.20 of tender part ii of price bid for full description 23 21 repairing work providing and fixing in position 304 grade stainless steel sink of nirali, or any other equivalent approved make of size: 610 mm x 460 mm ( overall size ) x 200 mm bowl inside depth including 40mm diameter heavy quality cp waste coupling, pvc waste pipe etc. complete . please refer sl.no.21 of tender part ii of price bid for full description 24 22 repairing work supplying & fixing new ewc floor mounted of approved make like hindware cedar, elba, approved equivalent with p or s trap, dual flush tank attached with ewc and solid seat cover. quoted rate shall include the cost of removal of existing wc from its position including its fitting, flush tank, supplying and fixing soil . please refer sl.no.22 of tender part ii of price bid for full description 25 23 repairing work providing and fixing 15 mm / 20mm dia full way valve of zoloto or approved equivalent make in the gi inlet lines including cutting, threading necessary taplon etc. all complete as directed.basic rate of full way valve rs. 900 / ( excluding gst ) . please refer sl.no.23 of tender part ii of price bid for full description 26 24a repairing work providing, fixing and testing following jaquar continental c.p. brass bath room and other fittings with flange wherever applicable 15mm dia two ways bib cock ( basic rate rs. 1900 / excluding gst ) . please refer sl.no.24a of tender part ii of price bid for full description 27 24b repairing work providing, fixing and testing following jaquar continental c.p. brass bath room and other fittings with flange wherever applicable angular stop cock of essco make. ( basic rate rs. 1125 / excluding gst. please refer sl.no.24b of tender part ii of price bid for full description 28 24c repairing work providing, fixing and testing following jaquar continental c.p. brass bath room and other fittings with flange wherever applicable health faucet with 1 mt. long pvc tube & wall hook matching with other fittings, of jaquar / hindware etc. make. ( basic rate rs. 1200 / excluding gst ) . please refer sl.no.24c of tender part ii of price bid for full description 29 24d repairing work providing, fixing and testing following jaquar continental c.p. brass bath room and other fittings with flange wherever applicable shower tap with mixture and handshower arrangement ( basic rate rs. 5300 / excluding gst ) . please refer sl.no.24d of tender part ii of price bid for full description 30 24e repairing work providing, fixing and testing following jaquar continental c.p. brass bath room and other fittings with flange wherever applicable shower head / rose round shape with shower arm casted 190mm long including base plate etc ( basic rate rs. 2400 / excluding gst ) . please refer sl.no.24e of tender part ii of price bid for full description 31 24f repairing work providing, fixing and testing following jaquar continental c.p. brass bath room and other fittings with flange wherever applicable hand shower with bracket ( basic rate rs. 1950 / excluding gst ) . please refer sl.no.24f of tender part ii of price bid for full description 32 24g repairing work providing, fixing and testing following jaquar continental c.p. brass bath room and other fittings with flange wherever applicable sink mixer for hot and cold water ( basic rate rs. 4000 / excluding gst ) . please refer sl.no.24g of tender part ii of price bid for full description 33 24h repairing work providing, fixing and testing following jaquar continental c.p. brass bath room and other fittings with flange wherever applicable single towel rail 600mm long basic rate rs. 1100 / excluding gst ) jaquar acn1111sm. please refer sl.no.24h of tender part ii of price bid for full description 34 24i repairing work providing, fixing and testing following jaquar continental c.p. brass bath room and other fittings with flange wherever applicable towel ring square basic rate rs. 1025 / excluding gst ) jaquar can chr 1121n. please refer sl.no.24i of tender part ii of price bid for full description 35 24j repairing work providing, fixing and testing following jaquar continental c.p. brass bath room and other fittings with flange wherever applicable soap dish holder jaquar acn chr 1131n basic rate rs. 395 / excluding gst ) . please refer sl.no.24j of tender part ii of price bid for full description 36 24k repairing work providing, fixing and testing following jaquar continental c.p. brass bath room and other fittings with flange wherever applicable tumbler holder acn chr 1143n basic rate rs. 1310 / excluding gst ) . please refer sl.no.24k of tender part ii of price bid for full description 37 24l repairing work providing, fixing and testing following jaquar continental c.p. brass bath room and other fittings with flange wherever applicable double coat hook acn chr 1161n basic rate rs. 450 / excluding gst ) . please refer sl.no.24l of tender part ii of price bid for full description 38 24m repairing work providing, fixing and testing following jaquar continental c.p. brass bath room and other fittings with flange wherever applicable glass shelf 600 mm long acn chr 1171n basic rate rs. 1000 / excluding gst ) . please refer sl.no.24m of tender part ii of price bid for full description 39 24n repairing work providing, fixing and testing following jaquar continental c.p. brass bath room and other fittings with flange wherever applicable corner glass shelf ( with bracket ) ( basic rate rs. 850 / excluding gst ) . please refer sl.no.24n of tender part ii of price bid for full description 40 24o repairing work providing, fixing and testing following jaquar continental c.p. brass bath room and other fittings with flange wherever applicable 15mm diameter 300 to 450mm long pvc connection with cp brass nuts and washers.. please refer sl.no.24o of tender part ii of price bid for full description 41 25 repairing work supplying and fixing approved quality float glass mirror of modi or tata or saint gobain or atul or any approved make. basic price 1300 rs per piece. please refer sl.no.25 of tender part ii of price bid for full description 42 26 repairing work providing and fixing 12mm thick ply / board green cost in cupboard inclusive of fevicol. bwp ply 710 grade of approved make & quality ( like green, century etc. ) with fixing 1mm laminate. cost inclusive of fevicol labour cost, necessary brass handle hinges knob etc basic price of laminate rs. 55.00 without gst. please refer sl.no.26 of tender part ii of price bid for full description 43 27 repairing work providing and applying two or more coats of acrylic emulsion paint ( premium ) of approved make and shade to walls ceiling and preparation of the surfaces by filling the putty to make even surface and providing and applying base coat of oil based cement primer of approved manufacture . please refer sl.no.27 of tender part ii of price bid for full description 44 28 repairing work providing & applying 2 or more coats of synthetic enamel paint to ms / wooden surfaces all approved make and shade including surface preparation by scrapping cleaning, filling the pot holes, smoothening the surface all complete as directed by banks engineer in charge. . please refer sl.no.28 of tender part ii of price bid for full description 45 29 repairing work providing and applying pop / birla wall putty on new plastered / old surfaces or wherever required as directed by bank?s engineer.please refer sl.no.29 of tender part ii of price bid for full description...

Military Engineer Services - Bihar

37044332 tender for special repair to omqs / smqs at af station bihta 1 excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 m deep and getting out including forming bottom surface for laying of pipes complete all as specified and directed. 2 returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 mm thick complete all as specified and directed. 3 removal of excavated material to a distance not exc 50 meter and depositing wheredirected at a level not exceeding 1.5 m above the starting point complete all as specified and directed. 4 supplying, laying and cushioning for cable protection in trenches 8 cm deep before laying cable and 15 cm deep over the cable including well punning complete all as specified and dierected 5 m&l cement concrete 1:5:10 type e2, using 40 mm graded stone coarse aggregate in sunken floor, all as specified and directed 6 m&lreinforced cement concrete (1:2:4) type b 1, (20 mm graded aggregate) as in slab supported on walls, beam, column and in similar work, complete all as specified and directed. 7 s & f for factory made solid pvc door frame of size 50mm x 47mm made out of 5mm plain colour pvc sheet, reinforced with ms square tube fixed in opening complete as per manufacturers specifications and as directed. 8 s & f for 30 mm thick factory made solid panel pvc door shutter conferming to criteria of testing as per is : 4020, consisting of frame made out of ms tube of 19 guage thickness & size 19x19mm for stiles and 15x15mm for top & bottom rails ms frames shall have a coat of red oxide primer of approved make and shall be covered with 5mm thick heat moulded pvc `c channel of size 30x50mm forming styles and 5mm thick 75mm wide pvc sheets for top rail lock rail and bottom rail on either side and 10mm (5mmx2) thick 20mm wide cross pvc sheet as gap insert for top rail and bottom rail panelling of 5 mm thick pvc sheet to be fitted in the ms frame welded/sealed to the stiles & rail with 30 mm wide x 5 mm thick pvc sheet beading on either side and joined together with solvent cement, adhesive and an additional 5 mm thick pvc strip of 20 mm width is to be struck on the interior side of c channel using pvc solvent adhesive complete as per manufacturers specifications & drawings & all as directed. 9 s & f pressed steel frames of size 125 x 60 mm for doors with one or more rebates including necessary fixing lugs hinges lock strike plate etc complete as specified. 10 s & f pressed steel frames of size 105 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete as specified. 11 m & l for pcc 1:3:6 type c 0 using 12.5mm aggregate crushed stone aggregate as in filling back side of pressed steel door/window frames, all as specified & directed. 12 s&f glazed/wire gauged/skeleton shutter 35 mm thick out of (well kilnseasoned)2nd class hard wood (hollock) the size of rails and style as per is chemically pressure treated in factory gainst termite infestation prepared to receive wire gauge (without sash bars) edges of frame chamfered or rounded fitted with cut and mitered beads, all as specified & directed.(note : wire gauge/glazing to be measured and paid separately). 13 s&f factory made 40 mm thick plain, framed, panelled shutter (two panel) with lock rail using 2nd class hw (hollock) kiln seasoned andchemicallypressure treated the size of rail and style as per is 1003 (part i) and panel insert of 9mm thick bwp commercial facing plywood or 12mm veneered particle boards with commercial ply all as specified 14 s&f plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed in 2nd class hardwood. 15 s&f of 25 mm thick flush shutters, solid core construction, with block board core and ply wood face panels, commercial type on both sides all as specified and as directed. 16 s&f in repairs of 12 mm thick plywood, grade bwr, type bb, fixed with screws to timber frame work etc. in built in cupboard complete all as specified and as directed. 17 s&f for 100mm long mild steel butt hinges, heavy weight cold rolled mild steel, all as specified and as directed. 18 s&f for 75mm long mild steel butt hinges, heavy weight cold rolled mild steel, all as specified and as directed. 19 s&f 150 mm long aluminium anodised handles, cast type, all as specified and as directed. 20 s&f for 150 mm long aluminium, anodised, barrel tower bolts of extruded section, all as specified and as directed. 21 s&f 300 mm long aluminium alloy, anodised, sliding dooor bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy, all as specified and as directed. 22 s&f for 200 mm long aluminium, anodised, barrel tower bolts of extruded section, all as specified and as directed. 23 s&f mild steel 300 mm ordinary rat tail rod pattern springs including roller & rooler plate complete all as specified and as directed. 24 s&f floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor overall length of cover plate 140mm, all as specified and as directed. 25 s&f hasp and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws of 100 mm size, all as specified and as directed. 26 s&f in repairs of harrison rail mild steel chromium plated of 19/20mm dia for curtain rod fixed with two nos of brackets for each rail all as specified and as directed. 27 s&f mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm, all as specified and as directed. 28 s&f anodised aluminium powder coated frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified & directed. (note : minimum thickness of powder coating 50 micron). 29 s&f anodised aluminium powder coated window and ventilator shutters, hung type without sash bar, aluminium section weighing not less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. anodised aluminium fittings such as peg stays 150 mm long (01 no), hinges b 21 100 mm long (02 no), suitable handle (01 no) complete all as specified.(note : minimum thickness of powder coating 50 micron). 30 s&f sheet glass 4 mm thick ordinary quality & glazing with rubber gasket in square n.exc 0.5 sqm in each pane, all as specified and directed.. 31 s&f 3 mm thick figured glass, pinhead type in squares n.exc 0.50 sqm each pane, all as specified and directed. 32 m&lfor mild steel tmt bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete, all specified and directed. 33 s&f in repair 18mm thick celuka pvc sheet minimum 600 kg/cum density grade 1 quality of both side plain white colour rigidlam glossy finish fixed with screws, solvent cement/adhesive as per manufacturer instructions to make kitchen cabinet sides top and bottom and shelves inside the cabinet completeas per specifications and as directed. note: (i) cup board accessories ie fittings,handles,hinges, will be measured and paid under this schedule.(ii) quoted rates deem to be include fixing of cabinet on wall with appropriate rawl plug/ dash through fastener (hammer type).(iii) fabrication and installation of cabinet to be carried out by authorised vendor of manufacturer only. 34 s&f auto closing stainless steel (grade 304) hinges 35 mm of 0 crank (kh 001) or 8 crank (kh 002) openable at 110 degree for kitchen cabinet shutters all as specified & directed. 35 s&f stainless steel handles of 100 mm size for kitchen cabinet shutter complete all as specified. 36 m&l for app basedpolymeric water proofing membrane minimum weight 3 kg/ sqm and minimum 3mm thick reinforced with polyster non wove fabrick (weight not less than 150gms/sqm), laid with torched application with the strict supervision of manufacturers technical supervisor, laid over hot blown bitumen 85/25 grade @1.2 kg per sqm over bitumen primer @0.30 ltr/sqm including cleaning surface, complete all as specified and directed.(note membrane shall be laid with 100mm side/end lap on prepared surface as per manufacturer instruction work shall be carried out strictly with the technical tradesmen and supervision of technical staff of manufacturer) 37 m&l for 40 mm thick brick tiles laid on bedding of 15 mm thick cement mortar (1:6) and joints grouted flush in cement mortar (1:3) on treated roof all as specified and as directed 38 m&l for applying bituminous primer @ 0.40 kg/sqm and applying one coat of hot blown bitumen of grade 85/25 @ 1.20 kg/sqm as in sunken complete all as specified including fixing of 40 mm dia gi spout pipe at bottom of slab/plastered surface etc, all as specified & directed. 39 roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc, all as specified & directed. 40 m&l for providing cement concrete type b 1, 1:2:4 (20 mm graded aggregate) as in roof padding, roof kerbs (rounded or chamfered on edge) etc all as specified & directed. 41 m&l 75 mm thick cement concrete type d 2, 1:4:8 (using 40 mm graded aggregate) as in subbase to floor, ll as specified and directed.. 42 m&l for 25 mm thick cement concrete type b 0, 1:2:4 (12.5 mm graded aggregate) as on floor, ll as specified and directed.. 43 m & lnon skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tiles including 15 mm thick screed bed in cement mortar 1:6 all as specified and directed. 44 m & lnon skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tiles including 15 mm thick screed bed 1:6 all as specified and directed. 45 m & l glazed ceramic coloured tiles of approved quality isi marked (450 x 300 x 7 mm / 350 x 250 x 7 mmthick) as in vertical surfaces such as skirting dados etc set jointed in neat cement slurry and pointed in coloured cement to match with the tiles including 1:4 cement plaster 10 mm thick on brick work and concrete surface, all as specified and directed. 46 m&l for 15 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms (including a hole of gas pipe) and like including 15 mm thick screed bed in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, all as specified and directed. 47 rounding to edges of stone slabs one edge, such as in steps, cooking platform, and similar situations, all as specified and directed.. 48 m&l for rendering 10 mm thick in cement mortor 1:4 on fair faces of brick work, surfaces finished even and fair without using extra cementwith water proofing compound, all as specified and directed. (note : wpc shall be measured and paid seperatelly). 49 m&l for 10 mm thick rendering in cement mortor (1:6) on air faces of brick work, surfaces finished even and smooth without using extra cement cement, all as specified and directed 50 m & l for 15 mm thick rendering in cm (1:4) on vertical surfaces of brick walls finished even and smooth without using extra cement with using water proofing compound, all as specified & directed. (note wpc will be measured and paid separately). 51 m&l for 5 mm thick rendering in cm (1:3) on ceiling surfacesoffinished even and fair without using extra cement, all as specified & directed.. 52 supply only integral water proofing compound 53 s&f 15 mm gi tubes medium grade with all fitting and fixed complete to walls, ceilings or laid infloors including taking up or down old steel tube complete all as specified and directed. 54 s&f 20 mm gi tubes medium grade with all fitting and fixed complete to walls, ceilings or laid infloors including taking up or down old steel tube complete all as specified and directed. 55 m&l for preparation of new wood basesurfaces of any description, over 10 cm in width or girth, not otherwise described and appling twocoats of synthetic enamel paint (ordinary tint) overone coats of pink primer, all as specified and directed. 56 m&l peparation of old painted wooden surfaes of any dscription over 10cm width or girth and applying one coatof synthetic enamel paint complete all as specified and as directed. 57 m&l peparation of old painted steel surfaces of any description over 10cmwidth or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. 58 m&l for preparation of new plastered surfaces of ceiling and applying three coats of white wash all as specified and directed. 59 m&l for preparation of old surfaces of ceiling and applying two coats of white washall as specified and directed. 60 m&l for preparation of new plastered surfaces of wall and applying three coats of white wash all as specified and directed. 61 m&l for preparation of old decorated plasteredsurfaces of wall and applying two coat of white wash all as specified and directed. 62 m&l for preparation of new plastered surfaces of wall and applying two coats oil bound distemper over a coat of alkali resistant primer over a coat of 1 mm thick wall care putty in two different layers complete all as specified & as directed.(note treatment slall be carried our by spraying with mechanical means) 63 m&l for complete removal of existing treatment of wall and applying two coats oil bound distemper over a coat of alkali resistant primer over a coat of 1 mm thick wall care putty in two different layers complete all as specified & as directed.(note treatment slall be carried our by spraying with mechanical means) 64 m&l for complete removing of existing treatment of wall surfaces by scrapping with mechanical sander (having mechanical vacuum mechanism)to make surface clean, free from dust, loose paint etc and applying two coat of cement base paint of different colours complete all as specified and directed. 65 m&l for preparation of new plastered surfaces of walls and applying two coat of cement base paint of any colours and pattern (two or more colours) complete all as specified and directed.(note : colour and pattern of paint will be directed by ge) 66 m&l for pvc (swr) pipe of 110 mm boresingle socketed in any length with rubber ring joint fixed to wall with suitable clamps of adequate numbers etc complete all as specified and directed. 67 s&fpvc swr bends 110 mm boreall as specified and directed. 68 s&f cast iron soil, waste pipe100 mm dia, sand cast, in any length with or without ear, with cement joint, laid in trenches, complete all as specified. 69 s&f cast iron soil, wastepipe100 mm dia, sand cast, in any length with or without ear, with cement joint, laid in trenches, complete all as specified. 70 s&f cast iron soil, waste and vent pipe100 mm dia, sand cast, in any length with or without ear, with cement joint, fixed on wall, complete all as specified. 71 s&f cast iron soil, waste and vent pipe100 mm dia, sand cast, in any length with or without ear, with cement joint, fixed on wall, complete all as specified & directed. 72 s & f in repairs of 100 mm bore cast iron bends of any radius diminshing pieces or tappers (larger bore measured), all as specified & directed.. 73 s & f in repairs of 75 mm bore cast iron bends of any radius diminshing pieces or tappers (larger bore measured), all as specified & directed.. 74 s&f cast iron cowls of 100 mm bore pipe, all as specified & directed. 75 s & f in repairs cast iron floor trap with chromium plated graating of 100 mm size including jointing to waste pipe with cement joints etc, all as specified & directed. 76 s&f soap dish brass chromium plated decorative type, size 160x90mm complete all as specifed and directed. 77 s&f 600 mm x 450 mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick ac buildg board or commercial plywood and fixed to wooden plugs with cpbrass screws and cup washers complete all as specified and directed. 78 s&f in repairbrass chromium plated, tubular towel rails 20 mm dia, d type, 60cm long between flanges, completed all as specified and directed. 79 s&f in repair chromium plated 125 mm size shower rose with swivel joints, in square with cp long shank arm including fixing to steel pipe or union of 15 mm bore, complete all as specified and as directed. 80 s&f in repairs vitreous china squatting pan “orissa pattern” of size 580 x 440mm white with integral foot rest (excluding flushing cistern & flush pipe) including connection to trap and to flush pipes etc and lime concrete bedding complete all as specified in ssr and including s&f trap set complete all as specified and directed. 81 s&f in repairs pvc flushing cistern 10 ltr capacity valve less syphonic action type low level with and including dual flushball valve float & handle, waste pipe & brackets complete set complete all as specified and directed. 82 s & f in repairvitreous china wash basin, flat back, size 630x450mm white, excluding waste coupling, chain & plug, ci prackets, pvc waste pipe 32 mm,and porcelain stopper but including brackets. 83 s&f in repair chromium plated fancy type, stop cock/angular cock, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends of size 15mm bore. complete all as specified and directed. 84 s&f in repair chromium plated concealed type, stop valve, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends of size 15mm bore. complete all as specified and directed. 85 s & f in repair 15mm bore chromium plated bib tap, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron or brass ferrule, complete all as specified and directed. 86 s&f sheet glass assembly consisting of 5.5mm thick sheet glass shelf 12mm wide with chromium plated bracket guard and railing, 600mm long,complete all as specified and directed. 87 s & f in repair pillar taps fancy type(long body)cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, screwed for iron pipe, complete all as specified and directed. 88 s&f in repairpvc connections 15mm size with ptmt nuts of length 450 mm, complete all as specified and as directed. 89 s&frotational moulded polythene water storage tank of capacity 500 ltrs (cylindrical/vertical with closed top), triple layer construction, isi marked, hoisted & fixed in position including followings : (i)20 mm gi pipe medium grade,over flow 450mm long.(ii) 20 mm gi pipe medium grade waste pipe 600mm long.(iii) 20 mm brass ball valve/float valves, high pressure & high density plastic ball screwed for iron pipe and fixed.(iv) 20 mm gun metal globe/gate valve with iron wheel head, screwed on both ends for fixing including one gi nipple(20mm bore). 90 s&f in repair sink with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and waste; including pvcwaste pipe, cp waste coupling,bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified anddirected. 91 s&f 1mm thick stainless steel kitchen plate rack of size 750x 900mm best quality assembled with brass washer and nut and bolts including hooks (spoon/cup holders) complete all as specified & directed. 92 demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level), all as specified & directed..note : all demolished items/ debris to be removed out side of mod land. 93 demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for, all as specified & directed..note : all demolished items/ debris to be removed out side of mod land. 94 demolition of reinforced cement concrete of any description & in any position, complete all as specified and directed. 95 dismantling of stone slabs and tiles of any description or thickness in floors aprons etc including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. 96 dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises,all as specified and directed. 97 taking down cement plaster on brick or stone walls, etc, incl raking out joints, hacking for key, scrubbing down with water, etc & prepare to receive new plaster complete all as specified and directed 98 taking down chowkats or frame with shutter (without taking out shutter from the frame) not exceeding 1.50 sqm each and removal from site all as specified and directed. 99 taking down chowkats or frame with shutter (without taking out shutter from the frame) exceeding 1.50 sqm and n exc 4.00 sqm each and removal from site all as specified and directed 100 taking down of shutters of any description exc 1.00 sqm but n. exc 2 sqm each, all as specified and directed 101 taiking up or down steel tubing and connections, 15 mm bore including cleaning, complete all as specified and directed. 102 taiking up or down steel tubing and connections, 20 mm bore including cleaning, complete all as specified and directed. 103 dismantling pvc water tankcapacity exceeding 250 but not exceeding 500 ltr, complete all as specified and directed. 104 taking down100/75 mm cast iron soil waste pipe (any size or patterns) moulding all fittings heads shoes, bends etc (measured over all as fixed along the confrece line over fittings and accessories), all as specified and directed. 105 taking down rain water pipes (any size or pattern) ,including all fittings all as specified and directted . 106 demolition of bricks (laid flat or on edge) or brick tiles in floors, channels, kerbs, aprons, etc (each layer) laid, bedded and pointed in any mortar including removal of debris/muds etc complete all as specified and as directed.note : all demolished items/ debris to be removed out side of mod land. 107 demolition of mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) and finally cleaning the surface with wire brush to remove old treatment to lay pcc padding, complete all as specified and directed..note : all demolished items/ debris to be removed out side of mod land 108 taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc, complete all as specified and directed. 109 taking down old unserviceable mcb db tpn4 way (vertical), double door, 415 v, ac, 50 hz, includingmcb63 amps 16 ka ,ip 40 protection conforming to is 13032 universal mounting with copper bus bar,neutral link, earth link, earthing studs, detachable gland plates with knockouts on both sides, complete all as specified & directed. 110 material and labour for concealed point wring for one light/fan/exhaust fan point controlled by 1 no,one way 5/6 amp switch ,using approved colour coding (phase red,neutral black,earth green) complete with frls pvc insulated and unshealthedstranded copper conductor cable 1.5 sqmm single coreconforming to is 694 including medium duty concealed unplasticised pvc conduit conforming to is 9537(part 3) and isi marked not less than 20 mm dia with concealed in wall pressed steel terminal box of not less than 2 mm thick of required size including painting terminal boxs inside and outside with two coat of synthetic enamle paint over one coat of red oxide primerwith top cover3 mm thickbakelight laminated sheetwith brass screws and cup washer with all assessories including frls pvc insulated and unshealthedstranded copper conductor cable 1.5 sqmm single core in green colouras earth wireconnected to earth dolly . complete all as specified and directed . 111 all as per item no 110 above butfor one 3 pin /5 pin socket outlet 5 amp controlled by 1 no one way 5/6 amp switch on same board along with other switches ,fan regulator etc. 112 all as per item no 110 above butfor one 3 pin /5 pin socket outlet 5 amp controlled by 1 no one way 5/6 amp switch on independent board. 113 all as per item no 110 above butfor one call bell/buzzer point controlled by one push button switch. 114 material and labour for point wring ,using approved colour coding (phase red,neutral black,earth green) complete for one socket outlet 15 amp on independent board with frls pvc insulated and unshealthedstranded copper conductor cable 2.5 sqmm single coreconforming to is 694 including medium duty concealed unplasticised pvc conduit conforming to is 9537(part 3) and isi marked not less than 20 mm dia with concealed in wall pressed steel terminal box of not less than 2 mm thick of required size including painting terminal boxs inside and outside with two coat of synthetic enamle paint over one coat of red oxide primerwith top cover3 mm thickbakelight laminated sheetwith brass screws and cup washer with all assessories including frls pvc insulated and unshealthedstranded copper conductor cable 2.5 sqmm single core in green colouras earth wireconnected to earth dolly complete all as specified and directed. 115 s&f switch piano flush button single pole one way 5/6 amp, 240 volts conforming to is 3854 isi marked all as specified and directed. 116 s&ffor socket outlet, 5 pin, 5/6 amp flush type conforming to is 1293 isi marked all as specified and directed. 117 s&f switch piano flush button single pole one way 15 amp, 240 volts conforming to is 3854 isi marked including taking down old one, all as specified and directed. 118 s&ffor socket outlet, 3 pin, 15 amp flush type conforming to is 1293 isi marked including taking down old one, all as specified and directed. 119 s&fceiling rose, surface bakelite,isolated bodythree terminals including taking down old one, all as specified and directed. 120 s&f lamp holder pvc/polycarbonate type with back plate suitable for batten fittings, all as specified and directed. 121 supply only led bulb of 09 watt complete all as specified and directed. 122 s&f forbell push flush type 5 a sp 240 v all as specified and directed. 123 s&fbell (ding dong) 230 volts, single pole all as specified and directed. 124 taking down ceiling fan including cable, dismantling blades and carry out mnr repair and fixing of damaged parts like capacitor, bushes, bearings and screws etc and keeping in safe custody of contractor up to re fixing in the same. all as specified & directed. 125 m&l for painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust, all as specified and directed. 126 hanging only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan, all as specified and directed. 127 m & l for repair / rewinding of ceiling fand replacement of requisite spares like bush, bearing, down rod, capacitor, fan clamp, fan blade etc if necessary all as specified and directed. 128 m & l for repair / rewinding of exaust fand replacement of requisite spares like bush, bearing, capacitor, fan clamp, fan blade etc if necessary all as specified and directed. 129 supply and fixing led tube lights fitting 1x 18w, 220v, including led tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling roseand complete all as specified and directed. 130 supply and fixing led batten type tube light complete fitting 1x 10 w, 220v,connecting up with three core flexible copper conductor cable of suitable size from ceiling roseand complete all as specified and directed. 131 supply &fixing and connecting up complete mcb db tpn 4 way (vertical), double door, 415 v, ac, 50 hz, with and includingmcb63 amps 16 ka ,ip 40 protection conforming to is 13032 universal mounting with copper bus bar,neutral link, earth link, earthing studs, detachable gland plates with knockouts on both sides, complete all as specified & directed. 132 s&f sheet metal enclosures (mcb distribution board) when mcb’s to be used singlepole and neutral 8 ways 220 volt with 200 amps rated bus bar, double door with bus bar neutral link earth bar, din rail, necessary blanking plated, including fixing db flush in wall complete with making good disturbed surfaces and colour matching all as specified and directed including taking down old one, complete all as specified & directed. 133 s&f mcb’s single pole, 10 ka ,32 amp to 40 amp 240 volts,and of b series with required wiring connections and lugs etc and erecting in provided enclouser/destribution board.mcbs shall be of current limiting type ,isi marked conforming to is 8828 1996, including taking down old one, complete all as specified & directed. 134 s&f sheet metalenclosure with socket plug top and mcbs single pole with a two pin and earth plug andsocket complete with one single pole mcb ofc series of cap 20 amps including taking out the old one all as specified and directed. 135 s&f mcb’s dp, 10 ka, 32 amp to 40 amp 240 volts,and of b series with required wiring connections and lugs etc and erecting in provided enclouser/destribution board. mcbs shall be of current limiting type ,isi marked conforming to is 8828 1996,including taking down old one complete all as directed. 136 supply and fixing stud 10 w led lights energy saving bulk head luminaries including led light driver, holder connecting up with three core flexible copper conductor cable of suitable size from ceiling roseand complete all as specified and directed. 137 s&f sub main wiring using approved colour coding (phase red,neutral black,earth green) complete with two single core frls pvc insulated and unsheathedstranded copper conductor cable 6 sqmmas current carrying conductor and one run of 6.0 sqmm as neutral cable ,voltage rating 1100 volt ,isi marked drawn in and including concealed pvc conduit isi marked of dia not less than 25 mm and thickness 2 mm with stranded accessories along with one run of frls pvc green colour insulated,unshealthed,stranded copper conductor of size 6 sqmm all as specified and directedincluding taking down old one, complete all as specified and directed.(note: two run of single core frls pvc cable with one run of earth contunity conductor and conduit shall be measured as one unit.) 138 m&l for earthing complete with galvanized steel earth plate 600x600x6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead wire of 4mm dia as earthing lead by means of bolts, nuts, check nuts, and washers of galvanised iron or steel besides welding at all joints as shown in drawings and including excavation and earth work, gi pipe light grade 15 mm bore for protection of giwire from earth electrodeto test point /machinery / equipment.supplying and laying charcoal dustcomman saltpcc(1:2:4) type b1 using 20 mm gradedstone agregratechamber andrcc cover 54 cm x 54cm x50 mm thick (1:2:4) type b 1using 20 mm stone agrigrtae )reinforced with 8 mm dia tmt bars @75mm c/c both ways with mild steel handle 12 mm dia,using round bar ,pgi funnel with wire mesh, 20 mm dia gi pipe medium grade for watering all as shown in electrical plate no 3 of ssr part 1including testing and taking out the old one complete all as specified and directed(note cost of gi wire and gi protection pipe up to a distance 7.5 m shall be includedin quated rate of above items) 139 s&f 415 v, 10 ka ,b curve miniature circuit breaker mcb tpn 63 amps, 16 ka complete all as specified and directed. 140 supply, laying, connecting and testing xlpe cable underground pvc insulated and over all sheathed with aluminium conductor heavy duty 1100 volts grade 3.5 core 35 sqmm sizes, laid in trenches, floors, ducts passing through pipe forroad crossing etc including taking down old unsv cable of any size complete all as directed including taking out old damaged cable and all as specified and directed. (note excavation, earth work, brick protection sand cushioningand gi pipe etc shall be measured & paid for separately) 141 m&l for laying of bricks subclass ‘b’ old size having crushing strengh not s than 75 kg/sqcm, laid flat perpendicular to the direction of cable for protection of cable complete all as specified & directed. 142 m&l gi tubing 50 mm dia light grade, laid in trench/floor or fixed on wall with all fixingaccessories etc as specified and directed. ...

Kendriya Vidyalaya Sangathan - Bihar

36542811 bids are invited for staff quarter m and r 2022 to 2023 geyser 10 litters , geyser 15 litters , geyser 25 litters , ceiling fan , fan regulator , kitchen exhaust fan , led tube 18 watt , led tube 20 watt , led tube 22 watt , ply board flush door , over head water tank , toilet flush system cistern , motor pump , upvc pipe , pvc solvent cement 100ml , elbo and bends , tee , bib cock water tap , teflon tape , chabi pvc inch , led bulb 9 watt , led buld 12 watt , water motor starter , wood paint enamel , wood primer paint , gi pipe for boring 10feet each , iron filter for boring 6feet each , power socket with switch full fitting set , water inlet and outlet angle cock for geyser , carpentry services , plumbing services , electrician services total quantity : 835...

Border Security Force - Bihar

34897140 bids are invited for procurement of stores in aor 152 bn bsf gi tee , gi nipple , fta , cpvc brass , elbow , pipe 20 mm , angle valve , bib cock , solvent cement , tape , pipe total quantity : 628...

Military Engineer Services - Bihar

34133519 day to day maintenance and certain other works at otm accn at mil stn gaya s&f in repair galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperature 1.18mm and fixed with beeding / staples directed by engg in charge. 2 hacking out old broken glass ( any the size quality or description ) from wooden or steel frames glazed all as specified and directed by engr in charge. 3 s&f 4mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares of any size complete all as specified and directed by engr in charge. 4 s&f 4mm thickfigured glass pin head type and glazing with oil putty or wooden beads in squares n exc 0.50 sqm each pane complete all as specified and directed. 5 s&f as in repair double legged door stopper of aluminium alloy with rubber all as specified and directed by engr in charge. make classic or equivalent 6 s&f 15mm size with stainless steel braided hose / connection pipe with brass nuts of length 900 mm all as specified and as directed. make: parryware / hindware / prayag 7 s&f as in repair pvc connections 15mm size with ptmt nuts of length 600 mm all as specified and as directed. make prayag / polytuff / symet 8 s&f as in repair pvc connections 15mm size with ptmt nuts of length 900 mm all as specified and as directed. prayag / polytuff / symet 9 supply & fix in repair brass chromium plated pillar cock log neck with aerator for wash hand basin screwed down for iron pipes suitable for 15mm bore pipe complete engr in charge. ( make parryware / prayag / hindware ) 10 s&f in repair 15 mm dia two way angle valves / bib taps, cast copper alloy, fancy type chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions ( make parryware / prayag / hindware ) 11 s &f as in repair chromium plated shower rose 125 mm dia with 600mm cp shower arm fancy type fixed to 15mm bore pipeall as specified and directed. ( make parryware / prayag / hindware ) 12 s & f cp as in repair jet spray complete all as specified & directed. ( make plumber / parryware / prayag / hindware ) 13 s & f as in repair normal closing white seat cover forewc incl accessories complete all as spd ( make jaguar / hindware / kohler ) 14 supplying and laying as in repair of cpvc pipes 20mm outer dia sdr 11 & plain cpvc sdr 11 fittings on walls / ceiling or laying in floors complete all as specified or laid in floors concealed or open of any length including taking down or up existing gi tubing & connections all as specified and directed by engr in charge. 15 supplying and laying as in repair of cpvc pipes 25mm outer dia sdr 11 & plain cpvc sdr 11 fittings on walls / ceiling or laying in floors complete all as specified or laid in floors concealed or open of any length including taking down or up existing gi tubing & connections all as specified and directed by engr in charge. 16 supplying and laying as in repair of cpvc pipes 32mm outer dia sdr 11 & plain cpvc sdr 11 fittings on walls / ceiling or laying in floors complete all as specified or laid in floors concealed or open of any length including taking down or up existing gi tubing & connections all as specified and directed by engr in charge. 17 s&f as in repair 15mm stop valves cast copper alloy chromium plated fancy type concealedtype screwed down high pressure with crutch or butterfly handle screwed down, high pressure with crutch screwed both ends for iron pipe or for unions and fixed in repairs all as specified and as directed make plumber / parryware / prayag 18 s&f in repair white colour rotational moulded three layer polyethylene water storage tanks ( cylindrical vertical with closed top ) capacity 500 ltrhoisted and fixed in position incl dismantlng and removing to store all as specified and directed by engr in charge. make; sintex / rotex / polycon 19 s&f in repair white colour rotational three layer moulded polyethylene water storage tanks ( cylinderical vertical with closed top ) capacity 1000 ltrhoisted and fixed in positionincl dismantlng and removing to storeall as specified and directed by engr in charge. make; sintex / rotex / polycon 20 s&f in repair white colour rotational three layer moulded polyethylene water storage tanks ( cylindrical vertical with closed top ) capacity 2000 ltrhoisted and fixed in positionincl dismantlng and removing to store all as specified and directed by engr in charge. make; sintex / rotex / polycon 21 demolition of brick work or stone / boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. 22 m&l brick workwith sub class b bricks straightor curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and directed. 23 taking down cement plaster any description on brick or stone walls or wall tiles etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. 24 m&l for rendering 5mmthick in ceiling on brick work or concrete surfaces in cm 1:4, finished even and smooth without using extra cement all as specified and directed. 25 m&l for rendering 10mm thick internal surfaces on other than fair faces of brick work in cm 1:6 as directed by engr in charge. 26 m&l for rendering 15mm thick external surfaces on brick / concrete in cm 1:4 finished even and smooth without using extra cement with wpc 2% by wt of cement.note: wpc measured and paid separatly 27 m&l for applying 1.00 mm thick wall care putty incl preparation of newly plastered wall surfaces 28 m&l for applying two coat of acrylic distemper over a coat of primer incl preparation of newly plastered wall surfaces 29 m&l for 2 coatsexterior emulsion paint over a coat of primerincluding preparation of newly plastered wall surfaces complete all as specified and directed 30 dismantling stone slabs and tiles of any description or thickness laid dry or laid dry and pointed in floors, aprons etc 31 m&l for granite ( any type ) work ( table rubbed and polished ) 18 to 20 mm thick in working platform and like including cutting for sink etc. in cement mortar ( 1:4 ) including rounding of edges and pointing in white cement ( 1:2 ) using marble dust with admixture of pigment to match.complete all as specified and as directed 32 dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing ) , removing serviceable tiles to store and rubbish off the premises 33 m & l coloured non skid ceramic coloured jointless tiles ( square / rectangular ) area of each tile exc 0.06 sqm but not exc. 0.11 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layer with cm 1:4 complete. 34 m & l coloured digital glazed ceramic coloured tiles in vertical surfaces 350x250x7mm / 450x350x 7 mmthick set and jointed in neat cement slurry and pointed in white or coloured cement to matchincl 10mm thick rendering in cement mortar 1:4as backing for tiles complete all as specified and as directed. 35 m&l for vitrified tiles double charge light shed 10 mm thick ( square or rectangular ) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed with and pointed in white or coloured cement to match over and incl 15mm thick screed bed or bedding layer with cm 1:4 complete. 36 m & l machine cut kota stone slab flooring 18 22mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing over and including screed bed or bedding layer of mortar 20 mm thick cement mortar 1:6. ( note : work will be carried out as in repair of patches in lieu of existing broken flooring ) 37 dismantling wallandceilingboards ( fibre, pulp, insulation, etc. ) or insulation boards / slabs / blankets, any thickness, including cover fillets 38 s&f in repairs of 4 mm thick hpsc ( high pressure steam cured ) pre primed textured designer board, water resistant, be placed in the grid system all as specified and directed by the engineer in charge. make : everest / armstrong 39 taking down chowkhats or frames not exc 1.5 sqm ( without taking shutters from the frame ) and removing to and from store complete 40 taking down chowkhats or frames exc 1.5 sqm but n exc 4sqm ( without taking shutters from the frame ) and removing to and from store complete 41 s&f powder coated aluminium frame / shutters for windows, ventilators sliding / openable etc icluding joining cleat for fixing, locking arrangement, rubber beading, screws, etc complete all as specified.make : jindal / hindalco / indalco. note : ( i ) glazing and wire mesh shall be measured and paid separetely. ( ii ) item shall be paid as per weight of aluminium section ( iii ) the rate quoted shall be inclusive of the cost of neoprene beading, glazing pin, screws and powder coated fittings such as locking arraangement etc as required, which shall not be measured for arriving the weight ( iv ) the rate shall also be inclusive of complete packing with silicon gel around contacting surfaces of aluminium work, and including matching the existing. 42 taking down existing aluminium door shutter with frame area exceeding 1 sqm and re fixing in same opening after repair / replace the defective jointing cleats / screws all as per specified and directed by engr in charge. 43 s & f of taper clips, tee, angles and other items for aluminium door complete. 44 s & f of rubber gasket for aluminium door glass complete 45 s & f aluminium handles, cast type, d shape anodised of size 150mm. 46 s&f galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperature 1.18mm and fixed with beeding / staples directed by engg in charge. 47 s&f 4 mm thicksheet glass, ordinary quality plain or tinted and glazing with rubber gasket in square exceeding 0.5 sqm in each pane, complete all as specified and directed. 48 s& f 100mm butt hinges, extruded stainless steel with hinge pin complete. make prayag or equivalent 49 s&f 200 mm long aluminium anodised barrel tower boltof extruded section. 50 s&f in repair steel locking bolts with mild steel electrogalvanised plate and bright bolt not less than 10 mm dia, 100 mm size 51 s&f as in repair 100 mm vertical type size mortice lock with four levers ( vertical type ) , mild steel body complete all as specified and directed. 52 supply only liquid water proofing compound 53 s & f in repair vitreous china wash down water closet pan ( pedestal pattern ) , white including fixing bolts, but excuding flushing cistern and flush pipe complete. make : jaguar / hindware / kohler 54 s & f as in repair vitreous china squatting pan, ‘orissa’ pattern, size 580 x 440 mm white, with integral foot rests, p trap water closet ( squatt pattern ) complete including provision of lime concrete bedding all as specified and directed 55 s & f as in repair10 litre pvc valveless, syphonic action type, dual type flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets ( make: parryware / hindware / jaguar ) 56 s&f as in repair vitreous china wash basin white flat back size 550 x 400mm excluding taps, waste, chain & plug and porcelain stopper but including brackets or fixed to walls with anchor fastnersall as specified and directed by engr in charge. ( make: parryware / hindware / cera ) 57 demolition of concrete in ground floors and pavings including floor tiles n exc 15 cm thickness ( below or above ground level ) 58 m&l for pcc 1:2:4 type b 1 using 20 mm graded stone aggregate as in floor finishes 40 mm thick laid in panels & finished even and smooth without using extra cement complete all as specified and directed. 59 m&l for pcc 1:2:4 type b 1 using 20 mm graded stone aggregate as in floor finishes 75 mm thick laid in panels & finished even and smooth without using extra cement complete all as specified and directed. 60 m&l for pvc ( swr ) pipessingle socketed, in any length with rubber ring joints, laid in trenches or in floors or walls of 110 mm bore of pipeincluding taking down etc complete all as specified and directed. 61 m&l for pvc ( swr ) pipessingle socketed, in any length with rubber ring joints, laid in trenches or in floors or walls of 75 mm bore of pipe including taking down etc complete all as specified and directed 62 s&f pvc ( swr ) bends isi marked any radius of 110 mm borewithaccess door complete all as specified and directed. 63 s&f pvc ( swr ) bends isi marked any radius of 75 mm borewithaccess door complete all as specified and directed. 64 s&f in repair 15 mm dia bore bib taps, cast copper alloy chromium plated fancy type with crutch alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed. ( make plumber / parryware / prayag ) 65 taking down chowkhats or frames not exc 1.5 sqm ( without taking shutters from the frame ) and removing to or from store complete. 66 s&f solid pvc door frame of size 50mm x 47mm made out of 5mm single side prelam pvc sheet & edges will be painted to match with prelam sheet reinforced with m.s. square tube, suppling & fixing in opening as per specification & drawing 67 s&f solid pvc factory madedoor shutter of 30mm ( style ) consisting of frame made out of ms tubes for top bottom rails ms frame shall be covered with heat moulded plain coloured pvc c channel having a pvc sheet strip 20mm width stuck inside with solvent cement for stilesa and plain coloured pvc sheets for top rail, lock & bottom rail on either sides & as gap insert for top rail & bottom rail panelling ofplain colour pvc sheet to be fitted in the ms frame welded / sealed to the stiles & rails with suitable pvc sheet beeding and jointed together with solvent cement as pere specification and drawing 68 s&f in repair aluminium body isi marked door closer hydraulically regulated, designation no. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specifiedand directedmake: hardwyn / marshal...

Bharatiya Rail Bijlee Company Limited - Bihar

33331822 bids are invited for procurement of cpvc pipe and fittings chlorinated pvc pipe 25mm sch80 pvc pipe f441 orf441m plain end cl5 nb 40mm cpvc pipe f441 or f441m plain end cl5 nb 50mm cpvc pipe f441 or f441m plain end cl5 nb 65mm cpvc pipe f441 or f441m plain end cl5 nb 80mm cpvc coupling sct type a f439 sch 80 size 1 inch cpvc coupling soc type a f439 sch80 size 1.5 inch cpvc coupling soc type a f439 sch 80 size 2 inch cpvc coupling soc type a f439 sch80 size 2.5 inch cpvc coupling soc type a f439 sch 80 size 3 inch f 439 elbow 90 soc a f439 sch 80 size 1 inch cpvc elbow 90 soc type a f439 sch80 size 1.5 inch cpvc elbow 90 soc type a f439 sch80 size 2 inch cpvc elbow 90 soc type a f439 sch80 size 2.5 inch cpvc elbow 90 soc type a f439 sch80 size 3 inch cpvc tee socket type a f439 sch80 size 1 inch cpvc tee socket type a f439 sch 80 size 1.5 inch cpvc tee socket type a f439 sch80 size 2 inch cpvc tee socket type af439 sch80 size 2.5 inch cpvc tee socket type a f439 sch80 size 3 red socket cpvc astm f439 sch 80 size 65x40 red socket cpvc astm f439 sch80 size 50x40 red socket cpvc astm f439 sch80 size 50x25 redu socket cpvc astm f439 sch80 size 40x25 red socket cpvc astm f439 sch 80 size 65x50 red socket cpvc astm f439 sch80 size 65x25 flange cpvc astm d4024 cl150 size 25mm flange cpvc astm d4024 cl150 size 40mm flange cpvc astm d4024 cl150 size 50mm flange cpvc astm d4024 cl 150 size 65mm flange cpvc astm d4024 cl150 dia 80mm solvent cement primer for pvc pipe or fitng solvent cement for pvc or pvcu pipe fitting ball valve flg cpvc cl150 size 80mm ball valve flg cpvc cl150 size 65mm ball valve flg cpvc cl150 size 25mm chlorinated pvc pipe 200mm sch 80 f441 / f441m chlorinated pvc pipe 200mm sch80 f441 diaphragm valve flng pn10 astm d1784 cpvc size 25mm diaphragm valve flng pn10 astm d1784 cpvc size 40mm diaphragm valve flng pn10 astm d1784 cpvc size 50mm diaphragm valve flng pn10 astm d1784 cpvc size 65mm cross socket cpvc astm f439 sch 80 dn size 1 inch cross socket cpvc astm f439 sch 80 dn size 2 inch cross socket cpvc astm f439 sch 80 dn 65 size 2 1 / 2 inch check valve ball type end connection and body material sw cpvc clorinated en iso161375 class150 nominal bore size 25mm check valve ball type end connection and body material sw cpvc clorinated en iso161375 class150 nominal bore size 40mm check valve ball type end connection and body material sw cpvc clorinated en iso161375 class150 nominal bore size 50mm ball valve acid or alkali end connection and body material flanged en iso 16135 cpvc class150 nominal bore 40mm ball valve acid or alkali end connection and body material flanged en iso 16135 cpvc class150 nominal bore 50mm total quantity : 2658...

Building Construction Department - Bihar

31641363 tender for brick work with fly ash bricks as per is 12894(2002) & is 3495 in foundations and plinth in cement mortar 1.6 (1 cement 6 coarse sand )extra for brick work in superstructure above plinth level upto floor v cum providing and laying ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of ist quality conforming to is 15622 of approved make in colours such shades except white ivory , grey fume red , brown , laid on 20 mm thick cement motar 1 4 (1 cement 4 coarse sand ) including pointing the joints with white cement and matching pigment etc . complete 1 supplying un skilled labour for dressing/hatching/leveling work etc supplying and filling in plinth with local sand and under floors including, watering, ramming consolidating and dressing complete. providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering all work upto plinth level.1:2:4(1 cement: 2 coarse sand:4 graded stone aggregate 20 mm nominal size) cement piaster in course sand 12 mm cement plaster of mix. 1:4(1 cement 4 coarse sand) providing 150mm wide brick drain in cement mortar (16) with av 150mm clear depth and 125mm apron concrete (1: 4.8), over one brick designation 100 a flat soling in proper grade and slope at the base, the drain duly plastered in cm (13) with punning over exposed surface all complete as per building specification and direction of ell, steel work in built up tubular trusses including cutting, hoisting, fixing in position and applying a priming coax of approved steel primer, welded and bolted including special shaped washers etc. complete hot finished welded type tubes kg 117 70 10 16.2 hot finished seamless type tubes pn fitting and fixing dura shine roof sheet etc all complete providing and fixing m, s. grills of required pattern in frames of windows etc with m.s. flats, square or round bars etc. including priming coat with approved steel primer all complete fixed to steel windows by welding. providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply, including all cpvc plain & brass threaded fittings, including fixing the pipe with clamps at 1 00 m spacing this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm dal 25 mm dal providing and fixing c.p brass bib cock of approved quality conforming to is:8931 providing and fixing c.p.brass stop cock (concealed) of standard design and of approved make conforming to is 8931. supplying plumber for repairing water supply line ,repairing flush cister,urinal connection, repairing peyawu connection, repairing submersible connection and cleaning water storage tank time to time voltas general & chilled water cooler 60/120 fss storage capacity 120l & cooling capacity 60 litre. full body steel made in india item size 141x141x141 cm (l w h) material stainless steel including with all fitting do to do job aqua dart 50 lph water purifier stainless steel with auto shut off and tds adjust 50 l ro water purifier (blue) including with all fitting do to do job painting with ready mixed paint of approved brand and manufacture in all shades to give an even shade new steel work (two or more coats) ...

Ministry Of Power - Bihar

31639486 bids are invited for cpvc pipes and fittings cpvc coupling soc type a f439 sch 80 6 inch, red socket cpvc astm f439 sch 80 50x40, red socket cpvc astm f439 sch 80 65x40+cc4 c27, red socket cpvc astm f439 sch 80 65x50, cpvc coupling soc type a f439 sch 80 4 inch, cpvc coupling soc type a f439 sch80 2.5 inch, cpvc coupling soc type a f439 sch 80 2 inch, cpvc coupling soc type a f439 sch80 1.5 inch, cpvc coupling sct type a f439 sch 80 1inch , flange cpvc astm d4024 cl 150 200 mm nb, flange cpvc astm d4024 cl 150 150 mm nb, flange cpvc astm d4024 cl 150 100mm, flange cpvc astm d4024 cl150 dia 80mm, flange cpvc astm d4024 cl 150 65mm, flange cpvc astm d4024 cl 150 50mm, flange cpvc astm d4024 cl 150 40mm, cpvc coupling soc type a f439 sch 80 8inch , red socket cpvc astm f439 sch 80 50x25, cpvc tee socket type a f439 sch 80 8inch , cpvc elbow 90 soc type a f439 sch80 1.5inch , cpvc elbow 90 soc type a f439 sch 80 2inch , cpvc elbow 90 soc type a f439 sch80 2.5inch , cpvc elbow 90 soc type a f439 sch 80 3inch , cpvc elbow 90 soc type a f439 sch 80 4inch , cpvc elbow 90 soc type a f439 sch 80 6inch , cpvc elbow 90 soc type a f439 sch 80 8inch , cpvc tee socket type a f439 sch 80 1inch , cpvc tee socket type a f439 sch 80 1.5inch , cpvc tee socket type a f439 sch 80 2inch , cpvc tee socket type a f439 sch 80 3inch , cpvc tee socket type a f439 sch 80 4inch , cpvc tee socket type a f439 sch 80 6inch , flange cpvc astm d4024 cl 150 25mm, solvent cement for pvc pipe / pipe fitting, solvent cement primer for pvc pipe / fitng, red socket cpvc astm f439 sch 80 200x150, red socket cpvc astm f439 sch 80 200x100, red socket cpvc astm f439 sch 80 100x50, red socket cpvc astm f439 sch 80 100x40, red socket cpvc astm f439 sch 80 100x25, red socket cpvc astm f439 sch 80 80x50, red socket cpvc astm f439 sch 80 80x40, cpvc pipe f441 / f441m plain end cl5 150mm, cpvc pipe f441 / f441m plain end cl5 100mm, cpvc pipe f441 / f441m plain end cl 5 80mm, cpvc pipe f441 / f441m plain end cl 5 65mm, cpvc pipe f441 / f441m plain end cl 5 50mm, pvc pipe f441 / f441m plain end cl 5 40mm, chlorinated pvc pipe 25mm sch80 astm 441, red socket cpvc astm f439 sch 80 80x25....

Central Public Works Department - Bihar

31234064 accessible india work at epfo main office building, patna earth work 1.1 supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 1.00 cum 2161.20 2161.00 2 cement concrete (cast in situ) 2.1 providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level : 2.1.1 1:2:4 (1 cement : 2 coarse sand (zone iii) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 1.00 cum 7365.15 7365.00 3 masonry work 3.1 half brick masonry with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 in foundations and plinth in : 3.1.1 cement mortar 1:3 (1 cement : 3 coarse sand) 24.00 sqm 862.90 20710.00 4 cladding work 4.1 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 180.00 sqm 1063.45 191421.00 5 wood and p. v. c. work 5.1 providing and fixing aluminium tow 5.1 providing and fixing aluminium tower bolts, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 5.1.1 150x10 mm 12.00 each 75.55 907.00 5.2 providing and fixing aluminium handles, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 5.2.1 125 mm 24.00 each 60.05 1441.00 schedule of quantity 45 5.3 providing and fixing factory made door frame (single rebate) made out of single piece extruded solid pvc foam profile with homogenous fine cellular structure having smooth outer integral skin having 62 mm width & 32 mm thickness, frame will be mitred & jointed with self driven self tapping screws of size 38 mm x 4 mm & pvc solvent cement, including fixing the frame to wall with suitable dia & length anchor fastener as per manufacturers specification and direction of engineer in charge. 62.00 metre 481.85 29875.00 5.4 providing and fixing factory made 30 mm thick door shutter made of solid pvc foam profile. the styles & rails shall be of size 75 mm x 30 mm having wall thickness 5 mm. the styles, top & bottom rails shall have one side wall thickness of 15 mm integrally extruded on the hinge side of the profile for better screw holding power. the styles and rails shall be reinforced with m.s. tubes of size 33 mm x 17 mmx 1 mm, painted with primer , all four corners of reinforcement to be welded or sealed. solid pvc extruded bidding (push fit type) will be s 5.4.1 decorative finish (both side wood grained finish) 23.00 sqm 3194.40 73471.00 6 steel work 6.1 providing and fixing stainless steel ( g 8 finishing 8.1 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 8.1.1 new work (two or more coats) over and including water thinnable priming coat with cement primer 95.00 sqm 162.55 15442.00 8.2 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 95.00 sqm 123.85 11766.00 9 repairs to building 9.1 dismantling 15 to 40 mm dia g.i. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of engineer in charge. (a) internal work exposed on wall 36.00 metre 2.85 103.00 10 dismantling and demolishing 10.1 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer in charge. 10.1.1 nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) 1.00 cum 2007.10 2007.00 10.2 demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer in charge. 10.2.1 in cement mortar 1.00 cum 1698.45 1698.00 10.3 dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. 10.3.1 for thickness of tiles 10 mm to 25 mm 485.00 sqm 60.50 29343.00 10.4 dismantling old plaster or skirting raking out joints and cleaning the surface for p 10.5 disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by engineer in charge, beyond 50 m initial lead, for all leads including all lifts involved. 10.00 cum 219.35 2194.00 11 road work 11.1 manufacturing, supplying and fixing retro reflective overhead signage boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type iii of astm d 4956 01 as approved by engineer in charge, letters, borders etc. as per irc : 67 2001 in silver white with blue colour back ground and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class ii of astm d 4956 01 and fixing the same to the plate of structural frame work by means of suitable sized aluminium alloys, rivets or bolts & nuts @ 300 mm centre to centre all along the periphery as well as in two vertical rows along with theft resistant measures, including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminium sheet including appropriate priming coat. the rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specification and direction of the engineerin charge.(structural frame work including m.s. plate to be provided separately. rectangular area of the sheet only shall be measured for payment). 11.1.1 overhead informatory road signage 15.00 sqm 5609.55 84143.00 11.2 providing and applying 2.5 mm thick oviding and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to is: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of engineer in charge. 11.00 sqm 1250.75 13758.00 11.4 providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to is:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of engineer in charge. 80.00 sqm 1719.00 137520.00 12 sanitary installations 12.1 providing and fixing wash basin with c.i. brackets, 15 mm c.p. brass pillar taps, 32 mm c.p. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 12.1.1 white vitreous china angle back wash basin size 600 x 480 mm with single 15mm c.p. brass pillar tap 12.00 each 2965.60 35587.00 12.2 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w. .3 providing and fixing cp brass 32mm size bottle trap of approved quality & make and as per the direction of engineer in charge. 8.00 each 886.25 7090.00 12.4 providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with c.p. brass screws and washers complete. 8.00 each 1411.15 11289.00 12.5 providing and fixing ptmt towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. 8.00 each 204.70 1638.00 49 12.6 providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cove 13 water supply 13.1 providing and fixing g.i. pipes complete with g.i. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : 13.1.1 15 mm dia nominal bore 24.00 metre 485.20 11645.00 13.1.2 20 mm dia nominal bore 12.00 metre 541.10 6493.00 13.2 providing and fixing uplasticised pvc connection pipe with brass unions : 13.2.1 30 cm length 13.2.1.1 15 mm nominal bore 20.00 each 74.80 1496.00 13.3 providing and fixing g.i. union in g.i. pipe including cutting and threading the pipe and making long screws etc. complete (new work) : 13.3.1 15 mm nominal bore 8.00 each 262.30 2098.00 13.3.2 20 mm nominal bore 8.00 each 289.05 2312.00 13.4 providing and fixing ptmt grating of approved quality and colour. 13.4.1 circular type 13.4.1.1 100 mm nominal dia 8.00 each 33.20 266.00 sh 14 non schedule 14.1 providing and laying rustic vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. size of tile 600x600 mm 14.2 providing and laying rustic vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. size of tile 600x600 mm 50.00 sqm 1135.20 56760.00 14.3 providing and fixing c.p. angular stop cock of jaquar brand , product code cqt 23053 & fixing as per engineer in charge . 20.00 each 836.30 16726.00 14.4 providing and fixing c.p. brass jaquar two way bib cock of brand code cqt 23041 and as per engineer in charge . 8.00 each 1194.15 9553.00 14.5 providing and fixing health faucet of jaquar branf code ald chr 573 , shower with 1m long flex tube in chromium finish & wall hook and as per engineer in charge . 8.00 each 268.32 2147.00 14.5 providing and fixing c.p. brass jaquar bib cock of brand code ari chr 39037 as per engineer in charge . 8.00 each 2068.75 16550.00 14.6 providing and fixing swing up s.s toilet grab bars in ph toilets of size 30 x 8 (weight 2.25 kg) make : kosmocare or equvilant 4.00 each 5034.00 20136.00 14.7 p/f ss grab bars in ph toilet 18 make pedder johanson or equivalent ...

Health And Family Welfare Department - Bihar

30458823 bids are invited for pile boring, providing and installation bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using direct mud circulation ( dmc ) or bailer and chisel technique by tripod and mechanical winch machine all complete, including removal of excavated earth with all its lifts and leads ( length of pile for payment shall be measured up to bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , upvc door providing and fixing of factory made upvc white colour casement door, upvc multichambered extruted frame, sash and mullion profile. frame duly reinforced with 1.2mm gi section box tpe chamber and sash with 1.5mm thick gi section ( ± 0.2mm ) based on wind load calculations ( shape and size according to upvc profiles ) , appropiate dimentions of upvc extruded glazing bead, epdm gasket ( k / o type ) , seperate drainage system, ss34 grade friction hinges 2d / 3d plate hinges, zinc alloy ( white powder coated ) casement handle, gi fastener 8x100 mm size for fixing frame to finish wall, plastic packer and caps and necessary steel screws etc.profile of frame and sash shall be metered cut and fusion welded at all corners, mullion shall be also fusion welded / joined mechanically including drilling of holes for fixing hardware and drainage of water etc. after fixing of frames , gap between frame and adjascent wall shall be filled with pu foaam / backer rod required size and the approved quantity. after that sealed with weather proof silicon sealant at both side, all complete as per approved drawing and direction of eic , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 1 providing and laying vitrified floor tiles in different sizes ( thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including grouting the joints with white cement and matching pigments etc., complete. size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge :flamed finish granite stone slab jet black, cherry red, elitebrown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item ( galvanised@80gsm ) 50 mm long 8mmouter diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’ , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975. the wind load shall be as per provisions of is 875 ( part iii ) . lgsfs frame shall be designed as per is: 801 using commercially available software such as frame cad pro 11.7 / staad pro v8i / architekv2.5.16 / revit architecture 2011 or equivalent. proper usage of connection accessories like heavy duty tension ties, light duty hold ons, twist straps ( to connect truss with wall frames ) , strong tie, tie rod, h brackets, boxing sections, l shaped angles for better structural stability. the framing section shall be cold form c type having minimum web depth 89 mm x 39mm flange x 11mm lip in required length as per structural design requirement duly punched with dimple / slot at required locations as per approved drawings. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm and. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , face panel providing and fixing in all exterior face panels breathable vapour barrier underneath the cementfiber board as per national building code 2009 complete as per direction of engineer in charge. , lap siding supplying and installation of moisture resistant / fire resistantlap siding 8 mm thick and width as per standard sizes made ofiber cement board with embossed decorative finish to give pleasing exterior fixed horizontally with staggered joints including minimum over lapof 32 mm external cement fibre boardconforming to is 14862:2000 offixed with self drilling / taping screws / fastners of approved make. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1 new work ( two or more coats ) over and including water tinnable priming coat with cement primer , ex. paint finishing walls with textured exterior paint of required shade : new work ( two or more coats applied @ 3.28 ltr / 10 sqm ) over and including priming coat of exterior primer applied @ 2.20kg / 10 sqm sqm , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel 1 steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , road providing and laying c.c. pavement of mix m 25 with ready mixed concrete from batching plant. the ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc.complete as per specifications and directions of engineer in charge. ( the panel shuttering work shall be paid for separately ) . ( note: cement content considered in this item is @ 330 kg / cum. excess / less cement used as per design mix is payable / recoverableseparately ) . , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 1 providing & fixing stone slab table rubbed, edges rounded and polished of size 75 x 50cm deep and 1.8 cm thick fixed in urinal patitions by cutting chase of appropriate width with chase cutter and embedding the stone in chase with epoxy grout or with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregste 6mm nominal size ) as per engineer in charge and finished smooth white agaria marble stone , phe 2 providing and fixing salem stainless steel a isi 304 ( 18 / 8 ) kitchen sink as per is: 13983 with ci brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required. kitchen sink with drain board510x1040mm bowl depth 200mm. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing:rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixturescomplete, including cutting and making good the walls andlevel whitep.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings andfloors wherever required :white vitreous china orissa pattern w.c. pan of size580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 9 providing and fixing cp brass 32mm size bottle trap of approved quality & make and as per the direction of engineer in charge.. ( sink & urinal ) , phe 10 providing & fixingptmt towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealedfittings arrangement of approved quality and colour weighing not less than 88 gms , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size 660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 15 providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water ( 250 ml & 500 ml consumption ) , having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of engineer in charge.. , phe 16 providing & fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. , phe 17 providing and fixing white vitreous china laboratory sink with c.i. brackets, c.p. brass chain with rubber plug, 40 mm c.p brass waste and 40mm c.p. brass trap with necessary c.p. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required :size 600x450x200 mm , phe 18 providing and fixing cp brass single lever telephonic wall mixer of quality & make as approved by engineer in charge . a ) 15 mm nominal dia. , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 21 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 24 two or more coats on new work over an under coat ofsuitable shade with ordinary paint of approved brand andmanufacturetwo more coast on new work , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm.clear depth and 250mm apron including cost of e / w. involved with 75mmcement concrete ( 1:4:8 ) over one brick designation 100 a flat soling inproper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 8 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia. exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 11 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 450 mm dia rcc pipe , ex. phe 12 inside size 120x90 cm and 90 cm deep including c.i. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg ) :with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , ex. phe 13 providing and fixing square mouth sw gully trap grade ‘a’ complete ci grating brick masonry chamber with bricks of class designation 75 and water tight ci cover with frame of 300 x 300 mm size ( inside ) the weight of cover to be not less than 13.00 kg and frame to be not less than 5 kg. as per standard design. ( cover min. 4.5 kg & frame min.2.7 kg ) 180x150 mm size p type with fps bricks , ex. phe 14 constructing masonry chamber 30x30x50 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement:4 coarce sand ) for stop cock complete with c.i. surface box 100x100x75mm ( inside ) with locking arrangement and rcc top slab 1:2:4 mix ( 1 cement : 2 corase sand: 4 graded stonr aggregate 20mm nominal size ) necessary excavation foundation concret 1:5:10 ( 1 cement:5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortor 1:3 ( 1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design. , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , ex. phe 16 structual steel work welded in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. , ex. phe 17 making connection of gi distribution branch with gi main of 50 80mm nominal bore by providing and fixing tee, including cutting and threading the pipe etc. complete. , rain water harvesting 1 boring / drilling bore well of required dia for casing / strainer pipe, bysuitable method prescribed in is:2800 ( part i ) , including collecting sample from different strata , preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90m depth below ground level.300 mm dia , rain water harvesting 2 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150mm nominal size dia , rain water harvesting 3 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well screen ( rms ) pipes with ribs, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150 mm nominal size dia , rain water harvesting 4 supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 5 supplying, filling, spreading & levelling gravel of size range 5mm to 10mm, in recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 7 providing and fixing bail plug / bottom plug of required dia to the bottom of pipe assembly of tube well as per is:2800 ( part i ) . 100 mm dia , rain water harvesting 8 making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and s.w. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , rain water harvesting 9 constructing soak pit 1.20x1.20x1.20 m filled with brickbats including s.w. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , tubewell 1 boring / drilling bore well of required dia for casing / strainer pipe, bysuitable method prescribed in is:2800 ( part i ) , including collecting sample from different strata , preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90m depth below ground level.300 mm dia , tubewell 2 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150mm nominal size dia , tubewell 3 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.100mm nominal size dia , tubewell 4 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well screen ( rms ) pipes with ribs, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.100 mm nominal size dia , tubewell 5 supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , tubewell 6 providing and fixing bail plug / bottom plug of required dia to the bottom of pipe assembly of tube well as per is:2800 ( part i ) . 100 mm dia , submersible pump 35m deep boring with casing and pipe. supply of pipe etc supplying & installation of suitable 2hp submersible pump b.s or k.s.bor equivalent make with finolex cable 1x3x2.5 squmm ( upto 50mtr ) withflexible conduit 25mm dia, electrical out door pannel with required electrical fitting such as mcb of 0 25amp ( havell or indocopp or mds make ) , volt & ampere meter ( ae make ) , single phase preventer ( minilac or vsp 1 make ) starter ( l&t or bch make ) etc of approved make, 40mm hdpe pipe ( 25 mtr ) and all accessories complete as per requirement of site. , water purifier and cooler 1 fitting and fixing single faucet storage type water cooler ( size 461 mm wide x 582 mm deep x 1217 mm height, weight 46 kg ) fully stainless body having storage capacity of 40 ltrs, cooling capacity of 40 ltrs. / hr. with hermetic type compressor, gas cooled motor equipped with over load protector, condensor for propeller type, thermostat autometically controlled temperature, refrigerent r 22, 230 volt, single phase 50 hertz, maximum current 2.3 amp including plug top and electrical lead wire connection upto 3 metres from the cooler, water inlet and drain out connections complete in all respects of voltas model no 40 / 40 tushar pss type or similar type of approved make. , water purifier and cooler 2 fitting and fixing water purifier for drinking purpose of capacity 6 litres / min, 5 purification system with reverse osmosis system with ultra ventilated membrane, tds500 to 2000 mgl / ppm, auto shut off with microswitch float manual flush facility, tds reduction 90% having automatic backwash system with filteration unit along with all accessories including plug top and electrical lead wire connection upto 3 metres from the purifier, water inlet and drain out connections complete in all respects similar to aquaguard or similar approved make ( model aquasure elegant ro water purifier of size width 360 mm x height 430 mm x depth 235 mm and weight 8.5 kg ) . , fire extinguisher 1 providing and fixing carbon di oxide type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. capacity 4.5 kg. , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 6.0 kg. , electrical 1 wiring for light point / fan point / exhaust fan point / call bellpoint with 1.5 sq.mm frls pvc insulated copper conductorsingle core cable in surface / recessed steel conduit, withmodular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. group c , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , pvc conduit 1 supplying and fixing of following sizes of medium class 20mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , pvc conduit 2 supplying and fixing of following sizes of medium class 32mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , pvc conduit 3 supplying and fixing of following sizes of medium class 50mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , electrical 4 wiring for light / power plug with 2x4 sq. mm frls pvcinsulated copper conductor single core cable in surface / recessed conduit alongwith 1 no. 4 sq. mm frls pvcinsulated copper conductor single core cable for loop earthingas required. , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 4 x 6 sq. mm + 2 x 6 sq. mm earth wire , wiring frls pvc insulated copper conductor 4 4 x 10 sq. mm + 2 x 6 sq. mm earth wire , wiring frls pvc insulated copper conductor 5 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 1 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 3 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 4 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 2 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 3 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 4 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 5 telephone socket outlet , s / f modular switch / socket on the existing modular plate 6 tv antenna socket outlet , s / f modular switch / socket on the existing modular plate 7 bell push , electrical 5 supplying & fixing suitable size gi box wih modular plate and cover in front on surface or in recess including providing and fixing 25 a modular socket outlet and 25 a modular sp mcb, “c” curve including connections, painting etc. as required. ( for ac / geyser ) , electrical 6 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface / recessed steel / pvc conduit as required. , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 11 supplying and fixing 20 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. , electrical 12 supplying and fixing 30 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , electrical 14 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 12 way , double door , electrical 15 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 16 way, double door , electrical 16 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 6 way ( 4 + 18 ) , double door , electrical 17 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way ( 4 + 24 ) , double door , electrical 18 supplying and fixing of following ways surface / recess mounting, vertical type, 415 v, tpn mcb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 a tinned copper bus bar, common neutral link, earth bar, din bar for mounting mcbs ( but without mcbs and incomer ) as required . ( note : vertical type mcb tpdb is normally usedwhere 3 phase outlets are required. ) 4 way ( 4 + 12 ) , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 63a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 100a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , l / f pvc sheathed / xlpe power cable in trench laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 95 sq. mm and upto 185 sq. mm , l / f pvc sheathed / xlpe power cable in trench 1 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 185 sq. mm and upto 400 sq. mm , l / f pvc sheathed / xlpe power cable over cable tray upto 35 sq. mm ( clamped with 1mm thick saddle ) , l / f pvc sheathed / xlpe power cable over cable tray 2 above 35 sq. mm and upto 95 sq. mm ( clamped with 25x3mm ms flat clamp ) , l / f pvc sheathed / xlpe power cable over cable tray 3 above 95 sq. mm and upto 185 sq. mm ( clamped with 25 / 40x3mm ms flat clamp ) , l / f pvc sheathed / xlpe power cable over cable tray 4 above 185 sq. mm and upto 400 sq. mm ( clamped with 40x3mm ms flat clamp ) , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 3.5c x 300 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 1 3.5c x 240 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 2 3.5c x 120 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 3 3.5c x 95 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 4 3.5c x 50 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 5 4c x 35 sqmm aluminium conductor cable a2xfy , cable tray supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 100 mm width x 50 mm depth x 1.6 mm thickness , cable tray 1 supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 300 mm width x 50 mm depth x 1.6 mm thickness , cable tray 2 supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 600 mm width x 62.5 mm depth x 2.0 mm thickness , cable tray “bends” supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.100 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 1 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.150 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 2 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.300 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 3 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.450 mm width x 50 mm depth x 2 mm thickness , cable tray “bends” 4 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.600 mm width x 62.5 mm depth x 2.0 mm thickness , mv cable supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 300 sqmm, aluminium conductor cable a2xfy , mv cable 1 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 240 sqmm, aluminium conductor cable a2xfy , mv cable 2 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 120 sqmm, aluminium conductor cable a2xfy , mv cable 3 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 95 sqmm, aluminium conductor cable a2xfy , earthing earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 1 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. , earthing 2 earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. , earthing 3 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 4 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , earthing 5 providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required. , earthing 6 providing and fixing earth bus of 50 mm x 5 mm copper strip on surface for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 4 supplying and fixing recess mounted 12 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 6 supply, installation, testing and commissioning of 400 mm sweep, 65w, blade material aluminium blades , speed & oscillation 3 speed, pull cord for speed and oscillation.air delivery minimum 72 m³ / min, speed minimun 1350 revolution per minute.suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , fiting & fixtures 8 supplying installation testing & commissioning ofb22 based 9w led 3 star bulb with 850 lumen, 6k color temperature including holder. , fiting & fixtures 9 supplying installation testing & commissioning of black painted extruded aluminium housing. green / red led’s mounted inside the housing. laser engraved signage matter on single / double acrylic sheet fixed on one side suitable for wall / ceiling / suspension type single / double sided display. in double sided version black paper is inserted. ni cd battery back up to 2 hrs. ( charged up to 8 10 hrs ) .mounting strings provided for pendent mounting operating voltage 150 280v ac ambient operating temperature. – 0 to 450c ingress protection – ip42.including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required.   220208 besl 03 led ssd wbb green 240 3 8wor220209 besl 03 led ssd wbb red 240 3 8wor220210 besl 03 led dsd wbb green 240 3 8wor220211 besl 03 led dsd wbb red 240 3 8w , fiting & fixtures 10 supply, installation, testing & erecting of ip66 bulkhead surface type lighting fixture 10w made up of pressure die cast aluminium housing and polyster powder coated die cast aluminium with high quality polycarbonate diffuser in opal finish for glare free light distribution.high efficiency long life led module with smd led package mounted on mcpcb with lumen efficacy of >95 lm / w with system lumen 950. powered by integral electronic led driver with apfc with low thd output short / open circuit protection. cct 5700, cri>80, system efficacy>90lm / w, thd<15%, pf>.95, ip66, ik 10, life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz.including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. cat ref: havells : hexaft10wled857ssymbopc or approved equivalent. , civil & misc works1 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. , civil & misc works2 providing and fixing h.t. danger notice plate of 250 mm x 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. , civil & misc works3 supplying and making cable route marker with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm x 60 cm at the bottom and 50 cm x 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. , civil & misc works4 supplying and fixing cable route marker with 10 cm x 10 cm x 5 mm thick g.i. plate with inscription there on, bolted / welded to 35 mm x 35 mm x 6 mm angle iron, 60 cm long and fixing the same in ground as required. , civil & misc works5 providing & fixing in position 1000 mm wide , electrical insulating rubber mats as per is 15652:2006, 2 mm thick, suitable up to 1.1 kv , fire retardant, no effect of acids, alkalis and transformer oils, moisture proof, high tensile strengthandtexture finish / cloth impression ( anti slip , marking on top ) , civil & misc works6 supply & fixing shock treatment chart duly mounted on a wooden frame with 5 mm thick glass as required ( approx front area 1.20 sq metre ) , 40 kvaups supplying, installation, testing and commissioningof online double conversion fully microprocessor based , indoor type, compact ups system of following rating with igbt based pwm technology to achieve thd < 3% and input power factor of greater than 0.95 at 50% loading, suitable for three phase ac input voltage 380 v to 440 v, 50 hz +3% / 3 % and three phase ac output voltage 415 ± 1% volts & frequency 50 ± 0.5 hz , inbuilt isolation transformer, necessary vrla batteries of suitable size having 30 minutes back up time , mounting rack including and suitable size connecting cable ( for ups to battery and battery to battery ) , static and maintenance bypass switch, snmp card for rs232 / ethernet ip computability for operation and monitoring etc. with all components as mentioned , specifications, complete as required.note : concerning vendor needs to furnish the battery sizing calculations at the time of ga approval and battery size has to be as per the approved ga drawing. , external lighting 1 supply and erection of 4 metre height hot dipgalvanized octagonal street light pole with followingarm with top dia 70 mm and bottom dia a / f 130 mm, made of 3 mm thick sheet along with base plate of size220 x 220 x 12 mm , small door opening for junctionbox mounting with mcb & connector, cement concreteof 1:3:6 including excavation, refilling and suitable sizefoundation bolts with template and all complete jobasrequired. ( but without pole collar ) single arm , external lighting 2 supplying and fixing 40 / 45 watt led type street lightwith die cast aluminium housing for ingress protectionof ip65 and complete with all accessories etc, onpole / building including connection with fr pvcinsulated copper conductor cable and earthing thebody etc. as required. , ip based cctv system 1 sitc of 2 megapixel @ 25fps, h.265 ip bullet camera, 1 / 2.9 cmos with 2.8~12mm varifocal lens, 0 lux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 2 sitc of 2 megapixel @ 25fps, h.265 ip dome camera, 1 / 2.9 cmos with 3.6 fixed mm 0 lux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 3 sitc of 2 megapixel @ 25fps, ptz camera h.265 ip dome camera, 1 / 2.9 cmos with 2.6 fixed lenslux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 4 sitc of 32ch 4k ivr , h.265 / h.264 • 1080p real time • 4k display • dual lan • 8x hdd • raid •web plugin free h.265 / h.264 compression technology 4k display for clear monitoring up to 1080p 16ch decoding ability smart search ii smart vca event searchsupport raid 0, 1, 5 supported to prevent from recording data loss browsers supported: ie , smart functions : target count, electric fence, face detection, humaniod detection, retrograde detection, leave position detectio output, local & network backup etc. complete as required. , cctv 5 sitc of harddiskdrive8tb, 24 / 7surveillance category only complete etc as required.etc.all complete , cctv 6 sitc of 55 led narrow bazel for monitoring for nvr server etc. all complete. , cctv 7 sitc of rj 45 outlets near the cameras etc. all complete. etc. all complete. , cctv 8 sitc of cat 6 patch cords 1 meter high quality four pair twisted stranded cable terminated with rj45 modular plugs at both the ends. , signage 1 providing & fixing of building direction signage mounted on pole, with pole of 100x100mm shs ( square hollow section ) of height of 5600mm, and sign size of 900x1050, sign made of aluminiu c section of 60mm with internal framing to support the frame in ms tubes hollow section, frame work duly painted with anti rust coatings, with facia of 3mm thick exterior grade aluminium composite panel, cladded with uv cured digital printed retroreflective sheet of 3m make, and back panel of 3mm exterior grade acp, all pipes to be painted in approved color. cost shall includecost towards installation, including excuvation and filling up with specified pcc and fixing of foundation bolts as specified, also it shall include the designing charges.all complete as per direction by engineer in charge. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , 2 tr air conditioning 1 split ac ( inverter model ) : supply, installation, testing, commissioning of split type wall mounted air conditioning units of following capacity including inddor, outdoor unit fitted with inverter based rotary compressor fitted with rotary compressor, copper condensor and first charge refrigent r410a / eco friendly green gas only, all complete including all electrical connections to the electrical power supply system of the building, includingbut not limited to supply of all electrical plugs, etc., as necessary, lengthening of all electrical wires of ac units ( both indoor and outdoor ) , drain pipe andincluding suitable voltage stabilisers, etc. so as to place them in a concealed manner in the desired position. the copper pipes and electrical cables shall be concealed in approved manner and neatly run in straight lines in a workman like manner with proper supports. complete supply and installation of split2 tr star rating 3 star , refrigerant piping copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 25 mm od, wall thickness >= 1.2 mm ( insulation 19 mm thick ) , refrigerant piping 1 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 19.1 mm od, wall thickness >= 1.0 mm ( insulation 13 mm thick ) , refrigerant piping 2 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 15.9 mm od, wall thickness >= 0.8 mm ( insulation 13 mm thick ) , refrigerant piping 3 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 9.5 mm od, wall thickness >= 0.8 mm ( insulation 13 mm thick ) , drain piping providing and fixing of cpvc 6 kg / cm2 drainpiping complete with fittings, supports, 6 mm thick closed cell elastomeric insulation as per specifications and drawings. 20 mm , drain piping 1 providing and fixing of cpvc 6 kg / cm2 drainpiping complete with fittings, supports, 6 mm thick closed cell elastomeric insulation as per specifications and drawings. 32 mm , main oxygen manifold supply, installation, testing and commissioning of following gas manifold system ( excluding cylinders ) . the manifold is configured for designed numbers of cylinders and is suitable to withstand a pressure of 145 kg / cm2, along withhigh pressure copper annealed tail pipes with end brass adapter suitable for cylinders and manifold. top frame comprising of high pressure copper pipes of size 1 / 2” nb x 15swg with high pressure brass fittings made of high tensile brass and connections through nonreturn valves, the design of middle and bottomframes is provided to fit both round and flat bottom cylinders safely. the manifold is tested ( hydraulically ) at 3500 psig. ( it should be ce and iso 13485 certified ) mani fold oxygen manifold 6 + 6 cylinder banks complete with nrv, middle frame, bottom frame with ce marked, , emergency manifold emergency oxygen manifold 01 + 01 cylinder emergency manifold with complete regulator, nrv, middle frame & bottom frame, , control panelfor oxygen fully automatic three port control panel for oxygen supply, installation, testing and commissioning of automatic manifold control panel would provide a duty or standby gas supply from two cylinder banks with automaticchangeover the manifold indicates local status and has a remote indicator facility. automaticmanifold control panel would be designed to supply the mgps with a constant pressure supply via a control panel form two equal banks of cylinders and the changeover from the ‘duty’ to the ‘standby’ bank of cylinders would beautomatic. automatic changeover from the duty to the standby bank would occur at a cylinder pressure that will ensure the maximum usage of the contents of the duty bank. the changeover unit would be provided with monitoring todetect and display: duty bank operating, duty bank empty, standby bank operating, and standby bank below 10 % when the duty bank is empty, reserve bank low, pipeline pressure fault. there would be facility to connect liquidoxygen supply ( i.e. three port control panel ) ( it should be ce and iso 13485 certified ) fully automatic three port control panel for oxygen , emergency manifold line regulator emergency manifold line regulator supply, installation, testing and commissioning of emergency manifold line regulator i n p u t p r e s s u r e 1 5 0 k g / c m 2 working pressure 4 kg / cm2 it should be ce and iso 13485 certified.oxygen input pressure 150 kg / cm2 working pressure 4 kg / cm2capacity : 1500 lpm , cylinderconnectingpipe ( pig tail ) supply, installation, testing and commissioning of cylinder connecting pipe ( pig tail ) made up of flexible ss hose with safety cord 5 / 8 inch bsp gland nut and one side 1 / 2 inch bsp internal threads having one meter length. ( oxygen 24 , n2o 10, co2 4 ) , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , medical air ( 4 bar ) outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve, supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified.42mm , isolation valve 2 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 28mm , isolation valve 3 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 22mm , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness , pipeline 4 medical grade copper pipeline ( in mtrs. ) as per en 13348, 28 mm ( od ) x 0.9 mm thickness , pipeline 5 medical grade copper pipeline ( in mtrs. ) as per en 13348, 42 mm ( od ) x 1.2 mm thickness , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 2268 mm x ( w ) 922 mm x ( h ) 610 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , paediatric bed with mattress paediatric bed of overall sizes in mm: 1500 ( l ) x 850 ( w ) x 1210 ( h ) flat single section bed with grille frame on 4 sides.suitable for children up to 12 years.drop down grill frame on both sides for protection of the patient.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral white , bed side locker type i over all dimension :402mmlx422mm wx840mm ht .locker should have one cabinet and one drawer unit .both provided with cam lock .there should be gap between drawer and unit to keep general items for frequesnt use castors are provided for easy handling .drawer made up of crca sheet 1 mm thick and has ball slide for easy operation .top ss 304 sheet 0.8 mm thick castors 50 mmdia , hamdle abs ..powder coating of epoxy polyester , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , strecher on trolley type i 2005mm ( l ) x666mm ( w ) x827mm ( h ) .the trolley should be made of 31.75 and 25.4 mm dia 1.6 mm thick erw tube.holder for stretcher should be made up of mild steel.castor should be of 200 mm dia , diagonal locking castor.stretcher should be made up oferw tubeof dia 25.4 mm and thickness 1.6 mm.top sheet should be made of crca sheetof thickness 1.2 mm with contour shape to accommodate patient.iv pole holder should be made ofms .maximum safe work load should be 135 kg.to ensure qood quality welding co2 argonprocess should be adhered to.all metal componentsshould be pre treated with zinc phosphating in 9 tank porcess and then powder coated with anti microbialepoxy polyster powder coating.goods should be supplied in knocked down construction to reduce carbon emission. performance test :proof loading test , cycle tests , impact test, salt spray test, castor break test, the manufacturer should compilant with iso 9001, 14001, 13485, ohsas 1800 and ce certification. , doctor desk type x s / f / f executive table main desk should be of dimesion : 1350w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. side panels : ( black ) made form 18mm thick plt with pvc lipping.modesty panel : made form 18mm thick plt with pvc lipping. bigger upper panel in black and smaller lower panel in white cedar. made from 18mm thick plt with pvc lipping. mobile pedestal : one box and one filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , chair type iii s / f / f executive chair1 ) seat / back assembly: the seat and back are made up of 1.2 cm. thick hot pressed plywood, upholstered withfabric upholstery covers and moulded polyurethane foam. the back foam is designed with contoured lumbar support for extra comfort. the seat has extra thick foam on front edge to give comfort to popliteal area.high back size : 47.5 cm ( w ) x 69.5 cm ( h ) seat size : 47.0 cm. ( w ) x 48.0 cm. ( d ) 2 ) polyurethane foam: the polyurethane foam is moulded with density = 45 + / 2 kg / m 3and hardness = 20 + / 2at 25% compression. 3 ) armrests: the one piece armrests are injection moulded from black co polymer polypropylene. 4 ) center tilt synchro mechanism : the mechanism is designed with the following features:• 360 revolving type. • upright position locking. • tilt tension adjustment.• seat / back tilting ratio of 1:3 ( 60 seat tilt / 180 back tilt ) . 5 ) pneumatic height adjustment : the pneumatic height adjustment has anadjustment stroke of 12.0 cm. 6 ) telescopic bellow assembly : the bellow is 3 piece telescopic type and injection moulded in black polypropylene. 7 ) pedestal assembly : . , staff / visitor chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck .3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement.mx load bearing capacity should be 10 kg. , hospital curtain tracks & i.v. tree system supply installation testing & commissioning of cubical tracks system made of powder coated aluminium alloy, stain free polyster fabric , water repellent curtains , smooth movement , non sticking runnner with stainless steel hooks made from mirror finish stainless steel , adjustable height with all accessories. total quantity : 1...

Health And Family Welfare Department - Bihar

30458807 bids are invited for pile boring, providing and installation bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using direct mud circulation ( dmc ) or bailer and chisel technique by tripod and mechanical winch machine all complete, including removal of excavated earth with all its lifts and leads ( length of pile for payment shall be measured up to bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , upvc door providing and fixing of factory made upvc white colour casement door, upvc multichambered extruted frame, sash and mullion profile. frame duly reinforced with 1.2mm gi section box tpe chamber and sash with 1.5mm thick gi section ( ± 0.2mm ) based on wind load calculations ( shape and size according to upvc profiles ) , appropiate dimentions of upvc extruded glazing bead, epdm gasket ( k / o type ) , seperate drainage system, ss34 grade friction hinges 2d / 3d plate hinges, zinc alloy ( white powder coated ) casement handle, gi fastener 8x100 mm size for fixing frame to finish wall, plastic packer and caps and necessary steel screws etc.profile of frame and sash shall be metered cut and fusion welded at all corners, mullion shall be also fusion welded / joined mechanically including drilling of holes for fixing hardware and drainage of water etc. after fixing of frames , gap between frame and adjascent wall shall be filled with pu foaam / backer rod required size and the approved quantity. after that sealed with weather proof silicon sealant at both side, all complete as per approved drawing and direction of eic , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 1 providing and laying vitrified floor tiles in different sizes ( thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including grouting the joints with white cement and matching pigments etc., complete. size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge :flamed finish granite stone slab jet black, cherry red, elitebrown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item ( galvanised@80gsm ) 50 mm long 8mmouter diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’ , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975. the wind load shall be as per provisions of is 875 ( part iii ) . lgsfs frame shall be designed as per is: 801 using commercially available software such as frame cad pro 11.7 / staad pro v8i / architekv2.5.16 / revit architecture 2011 or equivalent. proper usage of connection accessories like heavy duty tension ties, light duty hold ons, twist straps ( to connect truss with wall frames ) , strong tie, tie rod, h brackets, boxing sections, l shaped angles for better structural stability. the framing section shall be cold form c type having minimum web depth 89 mm x 39mm flange x 11mm lip in required length as per structural design requirement duly punched with dimple / slot at required locations as per approved drawings. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm and. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , face panel providing and fixing in all exterior face panels breathable vapour barrier underneath the cementfiber board as per national building code 2009 complete as per direction of engineer in charge. , lap siding supplying and installation of moisture resistant / fire resistantlap siding 8 mm thick and width as per standard sizes made ofiber cement board with embossed decorative finish to give pleasing exterior fixed horizontally with staggered joints including minimum over lapof 32 mm external cement fibre boardconforming to is 14862:2000 offixed with self drilling / taping screws / fastners of approved make. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1 new work ( two or more coats ) over and including water tinnable priming coat with cement primer , ex. paint finishing walls with textured exterior paint of required shade : new work ( two or more coats applied @ 3.28 ltr / 10 sqm ) over and including priming coat of exterior primer applied @ 2.20kg / 10 sqm sqm , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel 1 steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , road providing and laying c.c. pavement of mix m 25 with ready mixed concrete from batching plant. the ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc.complete as per specifications and directions of engineer in charge. ( the panel shuttering work shall be paid for separately ) . ( note: cement content considered in this item is @ 330 kg / cum. excess / less cement used as per design mix is payable / recoverableseparately ) . , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 1 providing & fixing stone slab table rubbed, edges rounded and polished of size 75 x 50cm deep and 1.8 cm thick fixed in urinal patitions by cutting chase of appropriate width with chase cutter and embedding the stone in chase with epoxy grout or with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregste 6mm nominal size ) as per engineer in charge and finished smooth white agaria marble stone , phe 2 providing and fixing salem stainless steel a isi 304 ( 18 / 8 ) kitchen sink as per is: 13983 with ci brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required. kitchen sink with drain board510x1040mm bowl depth 200mm. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing:rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixturescomplete, including cutting and making good the walls andlevel whitep.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings andfloors wherever required :white vitreous china orissa pattern w.c. pan of size580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 9 providing and fixing cp brass 32mm size bottle trap of approved quality & make and as per the direction of engineer in charge.. ( sink & urinal ) , phe 10 providing & fixingptmt towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealedfittings arrangement of approved quality and colour weighing not less than 88 gms , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size 660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 15 providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water ( 250 ml & 500 ml consumption ) , having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of engineer in charge.. , phe 16 providing & fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. , phe 17 providing and fixing white vitreous china laboratory sink with c.i. brackets, c.p. brass chain with rubber plug, 40 mm c.p brass waste and 40mm c.p. brass trap with necessary c.p. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required :size 600x450x200 mm , phe 18 providing and fixing cp brass single lever telephonic wall mixer of quality & make as approved by engineer in charge . a ) 15 mm nominal dia. , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 21 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 24 two or more coats on new work over an under coat ofsuitable shade with ordinary paint of approved brand andmanufacturetwo more coast on new work , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm.clear depth and 250mm apron including cost of e / w. involved with 75mmcement concrete ( 1:4:8 ) over one brick designation 100 a flat soling inproper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 8 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia. exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 11 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 450 mm dia rcc pipe , ex. phe 12 inside size 120x90 cm and 90 cm deep including c.i. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg ) :with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , ex. phe 13 providing and fixing square mouth sw gully trap grade ‘a’ complete ci grating brick masonry chamber with bricks of class designation 75 and water tight ci cover with frame of 300 x 300 mm size ( inside ) the weight of cover to be not less than 13.00 kg and frame to be not less than 5 kg. as per standard design. ( cover min. 4.5 kg & frame min.2.7 kg ) 180x150 mm size p type with fps bricks , ex. phe 14 constructing masonry chamber 30x30x50 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement:4 coarce sand ) for stop cock complete with c.i. surface box 100x100x75mm ( inside ) with locking arrangement and rcc top slab 1:2:4 mix ( 1 cement : 2 corase sand: 4 graded stonr aggregate 20mm nominal size ) necessary excavation foundation concret 1:5:10 ( 1 cement:5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortor 1:3 ( 1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design. , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , ex. phe 16 structual steel work welded in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. , ex. phe 17 making connection of gi distribution branch with gi main of 50 80mm nominal bore by providing and fixing tee, including cutting and threading the pipe etc. complete. , rain water harvesting 1 boring / drilling bore well of required dia for casing / strainer pipe, bysuitable method prescribed in is:2800 ( part i ) , including collecting sample from different strata , preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90m depth below ground level.300 mm dia , rain water harvesting 2 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150mm nominal size dia , rain water harvesting 3 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well screen ( rms ) pipes with ribs, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150 mm nominal size dia , rain water harvesting 4 supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 5 supplying, filling, spreading & levelling gravel of size range 5mm to 10mm, in recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 7 providing and fixing bail plug / bottom plug of required dia to the bottom of pipe assembly of tube well as per is:2800 ( part i ) . 100 mm dia , rain water harvesting 8 making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and s.w. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , rain water harvesting 9 constructing soak pit 1.20x1.20x1.20 m filled with brickbats including s.w. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , tubewell 1 boring / drilling bore well of required dia for casing / strainer pipe, bysuitable method prescribed in is:2800 ( part i ) , including collecting sample from different strata , preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90m depth below ground level.300 mm dia , tubewell 2 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150mm nominal size dia , tubewell 3 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.100mm nominal size dia , tubewell 4 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well screen ( rms ) pipes with ribs, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.100 mm nominal size dia , tubewell 5 supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , tubewell 6 providing and fixing bail plug / bottom plug of required dia to the bottom of pipe assembly of tube well as per is:2800 ( part i ) . 100 mm dia , submersible pump 35m deep boring with casing and pipe. supply of pipe etc supplying & installation of suitable 2hp submersible pump b.s or k.s.bor equivalent make with finolex cable 1x3x2.5 squmm ( upto 50mtr ) withflexible conduit 25mm dia, electrical out door pannel with required electrical fitting such as mcb of 0 25amp ( havell or indocopp or mds make ) , volt & ampere meter ( ae make ) , single phase preventer ( minilac or vsp 1 make ) starter ( l&t or bch make ) etc of approved make, 40mm hdpe pipe ( 25 mtr ) and all accessories complete as per requirement of site. , water purifier and cooler 1 fitting and fixing single faucet storage type water cooler ( size 461 mm wide x 582 mm deep x 1217 mm height, weight 46 kg ) fully stainless body having storage capacity of 40 ltrs, cooling capacity of 40 ltrs. / hr. with hermetic type compressor, gas cooled motor equipped with over load protector, condensor for propeller type, thermostat autometically controlled temperature, refrigerent r 22, 230 volt, single phase 50 hertz, maximum current 2.3 amp including plug top and electrical lead wire connection upto 3 metres from the cooler, water inlet and drain out connections complete in all respects of voltas model no 40 / 40 tushar pss type or similar type of approved make. , water purifier and cooler 2 fitting and fixing water purifier for drinking purpose of capacity 6 litres / min, 5 purification system with reverse osmosis system with ultra ventilated membrane, tds500 to 2000 mgl / ppm, auto shut off with microswitch float manual flush facility, tds reduction 90% having automatic backwash system with filteration unit along with all accessories including plug top and electrical lead wire connection upto 3 metres from the purifier, water inlet and drain out connections complete in all respects similar to aquaguard or similar approved make ( model aquasure elegant ro water purifier of size width 360 mm x height 430 mm x depth 235 mm and weight 8.5 kg ) . , fire extinguisher 1 providing and fixing carbon di oxide type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. capacity 4.5 kg. , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 6.0 kg. , electrical 1 wiring for light point / fan point / exhaust fan point / call bellpoint with 1.5 sq.mm frls pvc insulated copper conductorsingle core cable in surface / recessed steel conduit, withmodular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. group c , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , pvc conduit 1 supplying and fixing of following sizes of medium class 20mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , pvc conduit 2 supplying and fixing of following sizes of medium class 32mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , pvc conduit 3 supplying and fixing of following sizes of medium class 50mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , electrical 4 wiring for light / power plug with 2x4 sq. mm frls pvcinsulated copper conductor single core cable in surface / recessed conduit alongwith 1 no. 4 sq. mm frls pvcinsulated copper conductor single core cable for loop earthingas required. , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 4 x 6 sq. mm + 2 x 6 sq. mm earth wire , wiring frls pvc insulated copper conductor 4 4 x 10 sq. mm + 2 x 6 sq. mm earth wire , wiring frls pvc insulated copper conductor 5 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 1 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 3 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 4 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 2 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 3 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 4 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 5 telephone socket outlet , s / f modular switch / socket on the existing modular plate 6 tv antenna socket outlet , s / f modular switch / socket on the existing modular plate 7 bell push , electrical 5 supplying & fixing suitable size gi box wih modular plate and cover in front on surface or in recess including providing and fixing 25 a modular socket outlet and 25 a modular sp mcb, “c” curve including connections, painting etc. as required. ( for ac / geyser ) , electrical 6 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface / recessed steel / pvc conduit as required. , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 11 supplying and fixing 20 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. , electrical 12 supplying and fixing 30 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , electrical 14 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 12 way , double door , electrical 15 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 16 way, double door , electrical 16 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 6 way ( 4 + 18 ) , double door , electrical 17 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way ( 4 + 24 ) , double door , electrical 18 supplying and fixing of following ways surface / recess mounting, vertical type, 415 v, tpn mcb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 a tinned copper bus bar, common neutral link, earth bar, din bar for mounting mcbs ( but without mcbs and incomer ) as required . ( note : vertical type mcb tpdb is normally usedwhere 3 phase outlets are required. ) 4 way ( 4 + 12 ) , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 63a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 100a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , l / f pvc sheathed / xlpe power cable in trench laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 95 sq. mm and upto 185 sq. mm , l / f pvc sheathed / xlpe power cable in trench 1 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 185 sq. mm and upto 400 sq. mm , l / f pvc sheathed / xlpe power cable over cable tray upto 35 sq. mm ( clamped with 1mm thick saddle ) , l / f pvc sheathed / xlpe power cable over cable tray 2 above 35 sq. mm and upto 95 sq. mm ( clamped with 25x3mm ms flat clamp ) , l / f pvc sheathed / xlpe power cable over cable tray 3 above 95 sq. mm and upto 185 sq. mm ( clamped with 25 / 40x3mm ms flat clamp ) , l / f pvc sheathed / xlpe power cable over cable tray 4 above 185 sq. mm and upto 400 sq. mm ( clamped with 40x3mm ms flat clamp ) , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 3.5c x 300 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 1 3.5c x 240 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 2 3.5c x 120 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 3 3.5c x 95 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 4 3.5c x 50 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 5 4c x 35 sqmm aluminium conductor cable a2xfy , cable tray supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 100 mm width x 50 mm depth x 1.6 mm thickness , cable tray 1 supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 300 mm width x 50 mm depth x 1.6 mm thickness , cable tray 2 supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 600 mm width x 62.5 mm depth x 2.0 mm thickness , cable tray “bends” supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.100 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 1 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.150 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 2 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.300 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 3 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.450 mm width x 50 mm depth x 2 mm thickness , cable tray “bends” 4 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.600 mm width x 62.5 mm depth x 2.0 mm thickness , mv cable supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 300 sqmm, aluminium conductor cable a2xfy , mv cable 1 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 240 sqmm, aluminium conductor cable a2xfy , mv cable 2 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 120 sqmm, aluminium conductor cable a2xfy , mv cable 3 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 95 sqmm, aluminium conductor cable a2xfy , earthing earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 1 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. , earthing 2 earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. , earthing 3 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 4 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , earthing 5 providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required. , earthing 6 providing and fixing earth bus of 50 mm x 5 mm copper strip on surface for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 4 supplying and fixing recess mounted 12 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 6 supply, installation, testing and commissioning of 400 mm sweep, 65w, blade material aluminium blades , speed & oscillation 3 speed, pull cord for speed and oscillation.air delivery minimum 72 m³ / min, speed minimun 1350 revolution per minute.suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , fiting & fixtures 8 supplying installation testing & commissioning ofb22 based 9w led 3 star bulb with 850 lumen, 6k color temperature including holder. , fiting & fixtures 9 supplying installation testing & commissioning of black painted extruded aluminium housing. green / red led’s mounted inside the housing. laser engraved signage matter on single / double acrylic sheet fixed on one side suitable for wall / ceiling / suspension type single / double sided display. in double sided version black paper is inserted. ni cd battery back up to 2 hrs. ( charged up to 8 10 hrs ) .mounting strings provided for pendent mounting operating voltage 150 280v ac ambient operating temperature. – 0 to 450c ingress protection – ip42.including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required.   220208 besl 03 led ssd wbb green 240 3 8wor220209 besl 03 led ssd wbb red 240 3 8wor220210 besl 03 led dsd wbb green 240 3 8wor220211 besl 03 led dsd wbb red 240 3 8w , fiting & fixtures 10 supply, installation, testing & erecting of ip66 bulkhead surface type lighting fixture 10w made up of pressure die cast aluminium housing and polyster powder coated die cast aluminium with high quality polycarbonate diffuser in opal finish for glare free light distribution.high efficiency long life led module with smd led package mounted on mcpcb with lumen efficacy of >95 lm / w with system lumen 950. powered by integral electronic led driver with apfc with low thd output short / open circuit protection. cct 5700, cri>80, system efficacy>90lm / w, thd<15%, pf>.95, ip66, ik 10, life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz.including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. cat ref: havells : hexaft10wled857ssymbopc or approved equivalent. , civil & misc works1 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. , civil & misc works2 providing and fixing h.t. danger notice plate of 250 mm x 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. , civil & misc works3 supplying and making cable route marker with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm x 60 cm at the bottom and 50 cm x 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. , civil & misc works4 supplying and fixing cable route marker with 10 cm x 10 cm x 5 mm thick g.i. plate with inscription there on, bolted / welded to 35 mm x 35 mm x 6 mm angle iron, 60 cm long and fixing the same in ground as required. , civil & misc works5 providing & fixing in position 1000 mm wide , electrical insulating rubber mats as per is 15652:2006, 2 mm thick, suitable up to 1.1 kv , fire retardant, no effect of acids, alkalis and transformer oils, moisture proof, high tensile strengthandtexture finish / cloth impression ( anti slip , marking on top ) , civil & misc works6 supply & fixing shock treatment chart duly mounted on a wooden frame with 5 mm thick glass as required ( approx front area 1.20 sq metre ) , 40 kvaups supplying, installation, testing and commissioningof online double conversion fully microprocessor based , indoor type, compact ups system of following rating with igbt based pwm technology to achieve thd < 3% and input power factor of greater than 0.95 at 50% loading, suitable for three phase ac input voltage 380 v to 440 v, 50 hz +3% / 3 % and three phase ac output voltage 415 ± 1% volts & frequency 50 ± 0.5 hz , inbuilt isolation transformer, necessary vrla batteries of suitable size having 30 minutes back up time , mounting rack including and suitable size connecting cable ( for ups to battery and battery to battery ) , static and maintenance bypass switch, snmp card for rs232 / ethernet ip computability for operation and monitoring etc. with all components as mentioned , specifications, complete as required.note : concerning vendor needs to furnish the battery sizing calculations at the time of ga approval and battery size has to be as per the approved ga drawing. , external lighting 1 supply and erection of 4 metre height hot dipgalvanized octagonal street light pole with followingarm with top dia 70 mm and bottom dia a / f 130 mm, made of 3 mm thick sheet along with base plate of size220 x 220 x 12 mm , small door opening for junctionbox mounting with mcb & connector, cement concreteof 1:3:6 including excavation, refilling and suitable sizefoundation bolts with template and all complete jobasrequired. ( but without pole collar ) single arm , external lighting 2 supplying and fixing 40 / 45 watt led type street lightwith die cast aluminium housing for ingress protectionof ip65 and complete with all accessories etc, onpole / building including connection with fr pvcinsulated copper conductor cable and earthing thebody etc. as required. , ip based cctv system 1 sitc of 2 megapixel @ 25fps, h.265 ip bullet camera, 1 / 2.9 cmos with 2.8~12mm varifocal lens, 0 lux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 2 sitc of 2 megapixel @ 25fps, h.265 ip dome camera, 1 / 2.9 cmos with 3.6 fixed mm 0 lux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 3 sitc of 2 megapixel @ 25fps, ptz camera h.265 ip dome camera, 1 / 2.9 cmos with 2.6 fixed lenslux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 4 sitc of 32ch 4k ivr , h.265 / h.264 • 1080p real time • 4k display • dual lan • 8x hdd • raid •web plugin free h.265 / h.264 compression technology 4k display for clear monitoring up to 1080p 16ch decoding ability smart search ii smart vca event searchsupport raid 0, 1, 5 supported to prevent from recording data loss browsers supported: ie , smart functions : target count, electric fence, face detection, humaniod detection, retrograde detection, leave position detectio output, local & network backup etc. complete as required. , cctv 5 sitc of harddiskdrive8tb, 24 / 7surveillance category only complete etc as required.etc.all complete , cctv 6 sitc of 55 led narrow bazel for monitoring for nvr server etc. all complete. , cctv 7 sitc of rj 45 outlets near the cameras etc. all complete. etc. all complete. , cctv 8 sitc of cat 6 patch cords 1 meter high quality four pair twisted stranded cable terminated with rj45 modular plugs at both the ends. , signage 1 providing & fixing of building direction signage mounted on pole, with pole of 100x100mm shs ( square hollow section ) of height of 5600mm, and sign size of 900x1050, sign made of aluminiu c section of 60mm with internal framing to support the frame in ms tubes hollow section, frame work duly painted with anti rust coatings, with facia of 3mm thick exterior grade aluminium composite panel, cladded with uv cured digital printed retroreflective sheet of 3m make, and back panel of 3mm exterior grade acp, all pipes to be painted in approved color. cost shall includecost towards installation, including excuvation and filling up with specified pcc and fixing of foundation bolts as specified, also it shall include the designing charges.all complete as per direction by engineer in charge. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , 2 tr air conditioning 1 split ac ( inverter model ) : supply, installation, testing, commissioning of split type wall mounted air conditioning units of following capacity including inddor, outdoor unit fitted with inverter based rotary compressor fitted with rotary compressor, copper condensor and first charge refrigent r410a / eco friendly green gas only, all complete including all electrical connections to the electrical power supply system of the building, includingbut not limited to supply of all electrical plugs, etc., as necessary, lengthening of all electrical wires of ac units ( both indoor and outdoor ) , drain pipe andincluding suitable voltage stabilisers, etc. so as to place them in a concealed manner in the desired position. the copper pipes and electrical cables shall be concealed in approved manner and neatly run in straight lines in a workman like manner with proper supports. complete supply and installation of split2 tr star rating 3 star , refrigerant piping copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 25 mm od, wall thickness >= 1.2 mm ( insulation 19 mm thick ) , refrigerant piping 1 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 19.1 mm od, wall thickness >= 1.0 mm ( insulation 13 mm thick ) , refrigerant piping 2 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 15.9 mm od, wall thickness >= 0.8 mm ( insulation 13 mm thick ) , refrigerant piping 3 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 9.5 mm od, wall thickness >= 0.8 mm ( insulation 13 mm thick ) , drain piping providing and fixing of cpvc 6 kg / cm2 drainpiping complete with fittings, supports, 6 mm thick closed cell elastomeric insulation as per specifications and drawings. 20 mm , drain piping 1 providing and fixing of cpvc 6 kg / cm2 drainpiping complete with fittings, supports, 6 mm thick closed cell elastomeric insulation as per specifications and drawings. 32 mm , main oxygen manifold supply, installation, testing and commissioning of following gas manifold system ( excluding cylinders ) . the manifold is configured for designed numbers of cylinders and is suitable to withstand a pressure of 145 kg / cm2, along withhigh pressure copper annealed tail pipes with end brass adapter suitable for cylinders and manifold. top frame comprising of high pressure copper pipes of size 1 / 2” nb x 15swg with high pressure brass fittings made of high tensile brass and connections through nonreturn valves, the design of middle and bottomframes is provided to fit both round and flat bottom cylinders safely. the manifold is tested ( hydraulically ) at 3500 psig. ( it should be ce and iso 13485 certified ) mani fold oxygen manifold 6 + 6 cylinder banks complete with nrv, middle frame, bottom frame with ce marked, , emergency manifold emergency oxygen manifold 01 + 01 cylinder emergency manifold with complete regulator, nrv, middle frame & bottom frame, , control panelfor oxygen fully automatic three port control panel for oxygen supply, installation, testing and commissioning of automatic manifold control panel would provide a duty or standby gas supply from two cylinder banks with automaticchangeover the manifold indicates local status and has a remote indicator facility. automaticmanifold control panel would be designed to supply the mgps with a constant pressure supply via a control panel form two equal banks of cylinders and the changeover from the ‘duty’ to the ‘standby’ bank of cylinders would beautomatic. automatic changeover from the duty to the standby bank would occur at a cylinder pressure that will ensure the maximum usage of the contents of the duty bank. the changeover unit would be provided with monitoring todetect and display: duty bank operating, duty bank empty, standby bank operating, and standby bank below 10 % when the duty bank is empty, reserve bank low, pipeline pressure fault. there would be facility to connect liquidoxygen supply ( i.e. three port control panel ) ( it should be ce and iso 13485 certified ) fully automatic three port control panel for oxygen , emergency manifold line regulator emergency manifold line regulator supply, installation, testing and commissioning of emergency manifold line regulator i n p u t p r e s s u r e 1 5 0 k g / c m 2 working pressure 4 kg / cm2 it should be ce and iso 13485 certified.oxygen input pressure 150 kg / cm2 working pressure 4 kg / cm2capacity : 1500 lpm , cylinderconnectingpipe ( pig tail ) supply, installation, testing and commissioning of cylinder connecting pipe ( pig tail ) made up of flexible ss hose with safety cord 5 / 8 inch bsp gland nut and one side 1 / 2 inch bsp internal threads having one meter length. ( oxygen 24 , n2o 10, co2 4 ) , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , medical air ( 4 bar ) outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve, supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified.42mm , isolation valve 2 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 28mm , isolation valve 3 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 22mm , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness , pipeline 4 medical grade copper pipeline ( in mtrs. ) as per en 13348, 28 mm ( od ) x 0.9 mm thickness , pipeline 5 medical grade copper pipeline ( in mtrs. ) as per en 13348, 42 mm ( od ) x 1.2 mm thickness , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 2268 mm x ( w ) 922 mm x ( h ) 610 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , paediatric bed with mattress paediatric bed of overall sizes in mm: 1500 ( l ) x 850 ( w ) x 1210 ( h ) flat single section bed with grille frame on 4 sides.suitable for children up to 12 years.drop down grill frame on both sides for protection of the patient.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral white , bed side locker type i over all dimension :402mmlx422mm wx840mm ht .locker should have one cabinet and one drawer unit .both provided with cam lock .there should be gap between drawer and unit to keep general items for frequesnt use castors are provided for easy handling .drawer made up of crca sheet 1 mm thick and has ball slide for easy operation .top ss 304 sheet 0.8 mm thick castors 50 mmdia , hamdle abs ..powder coating of epoxy polyester , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , strecher on trolley type i 2005mm ( l ) x666mm ( w ) x827mm ( h ) .the trolley should be made of 31.75 and 25.4 mm dia 1.6 mm thick erw tube.holder for stretcher should be made up of mild steel.castor should be of 200 mm dia , diagonal locking castor.stretcher should be made up oferw tubeof dia 25.4 mm and thickness 1.6 mm.top sheet should be made of crca sheetof thickness 1.2 mm with contour shape to accommodate patient.iv pole holder should be made ofms .maximum safe work load should be 135 kg.to ensure qood quality welding co2 argonprocess should be adhered to.all metal componentsshould be pre treated with zinc phosphating in 9 tank porcess and then powder coated with anti microbialepoxy polyster powder coating.goods should be supplied in knocked down construction to reduce carbon emission. performance test :proof loading test , cycle tests , impact test, salt spray test, castor break test, the manufacturer should compilant with iso 9001, 14001, 13485, ohsas 1800 and ce certification. , doctor desk type x s / f / f executive table main desk should be of dimesion : 1350w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. side panels : ( black ) made form 18mm thick plt with pvc lipping.modesty panel : made form 18mm thick plt with pvc lipping. bigger upper panel in black and smaller lower panel in white cedar. made from 18mm thick plt with pvc lipping. mobile pedestal : one box and one filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , chair type iii s / f / f executive chair1 ) seat / back assembly: the seat and back are made up of 1.2 cm. thick hot pressed plywood, upholstered withfabric upholstery covers and moulded polyurethane foam. the back foam is designed with contoured lumbar support for extra comfort. the seat has extra thick foam on front edge to give comfort to popliteal area.high back size : 47.5 cm ( w ) x 69.5 cm ( h ) seat size : 47.0 cm. ( w ) x 48.0 cm. ( d ) 2 ) polyurethane foam: the polyurethane foam is moulded with density = 45 + / 2 kg / m 3and hardness = 20 + / 2at 25% compression. 3 ) armrests: the one piece armrests are injection moulded from black co polymer polypropylene. 4 ) center tilt synchro mechanism : the mechanism is designed with the following features:• 360 revolving type. • upright position locking. • tilt tension adjustment.• seat / back tilting ratio of 1:3 ( 60 seat tilt / 180 back tilt ) . 5 ) pneumatic height adjustment : the pneumatic height adjustment has anadjustment stroke of 12.0 cm. 6 ) telescopic bellow assembly : the bellow is 3 piece telescopic type and injection moulded in black polypropylene. 7 ) pedestal assembly : . , staff / visitor chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck .3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement.mx load bearing capacity should be 10 kg. , hospital curtain tracks & i.v. tree system supply installation testing & commissioning of cubical tracks system made of powder coated aluminium alloy, stain free polyster fabric , water repellent curtains , smooth movement , non sticking runnner with stainless steel hooks made from mirror finish stainless steel , adjustable height with all accessories. total quantity : 1...

Health And Family Welfare Department - Bihar

30458798 bids are invited for pile boring, providing and installation bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using direct mud circulation ( dmc ) or bailer and chisel technique by tripod and mechanical winch machine all complete, including removal of excavated earth with all its lifts and leads ( length of pile for payment shall be measured up to bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , upvc door providing and fixing of factory made upvc white colour casement door, upvc multichambered extruted frame, sash and mullion profile. frame duly reinforced with 1.2mm gi section box tpe chamber and sash with 1.5mm thick gi section ( ± 0.2mm ) based on wind load calculations ( shape and size according to upvc profiles ) , appropiate dimentions of upvc extruded glazing bead, epdm gasket ( k / o type ) , seperate drainage system, ss34 grade friction hinges 2d / 3d plate hinges, zinc alloy ( white powder coated ) casement handle, gi fastener 8x100 mm size for fixing frame to finish wall, plastic packer and caps and necessary steel screws etc.profile of frame and sash shall be metered cut and fusion welded at all corners, mullion shall be also fusion welded / joined mechanically including drilling of holes for fixing hardware and drainage of water etc. after fixing of frames , gap between frame and adjascent wall shall be filled with pu foaam / backer rod required size and the approved quantity. after that sealed with weather proof silicon sealant at both side, all complete as per approved drawing and direction of eic , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 1 providing and laying vitrified floor tiles in different sizes ( thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including grouting the joints with white cement and matching pigments etc., complete. size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge :flamed finish granite stone slab jet black, cherry red, elitebrown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item ( galvanised@80gsm ) 50 mm long 8mmouter diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’ , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975. the wind load shall be as per provisions of is 875 ( part iii ) . lgsfs frame shall be designed as per is: 801 using commercially available software such as frame cad pro 11.7 / staad pro v8i / architekv2.5.16 / revit architecture 2011 or equivalent. proper usage of connection accessories like heavy duty tension ties, light duty hold ons, twist straps ( to connect truss with wall frames ) , strong tie, tie rod, h brackets, boxing sections, l shaped angles for better structural stability. the framing section shall be cold form c type having minimum web depth 89 mm x 39mm flange x 11mm lip in required length as per structural design requirement duly punched with dimple / slot at required locations as per approved drawings. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm and. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , face panel providing and fixing in all exterior face panels breathable vapour barrier underneath the cementfiber board as per national building code 2009 complete as per direction of engineer in charge. , lap siding supplying and installation of moisture resistant / fire resistantlap siding 8 mm thick and width as per standard sizes made ofiber cement board with embossed decorative finish to give pleasing exterior fixed horizontally with staggered joints including minimum over lapof 32 mm external cement fibre boardconforming to is 14862:2000 offixed with self drilling / taping screws / fastners of approved make. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1 new work ( two or more coats ) over and including water tinnable priming coat with cement primer , ex. paint finishing walls with textured exterior paint of required shade : new work ( two or more coats applied @ 3.28 ltr / 10 sqm ) over and including priming coat of exterior primer applied @ 2.20kg / 10 sqm sqm , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel 1 steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , road providing and laying c.c. pavement of mix m 25 with ready mixed concrete from batching plant. the ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc.complete as per specifications and directions of engineer in charge. ( the panel shuttering work shall be paid for separately ) . ( note: cement content considered in this item is @ 330 kg / cum. excess / less cement used as per design mix is payable / recoverableseparately ) . , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 1 providing & fixing stone slab table rubbed, edges rounded and polished of size 75 x 50cm deep and 1.8 cm thick fixed in urinal patitions by cutting chase of appropriate width with chase cutter and embedding the stone in chase with epoxy grout or with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregste 6mm nominal size ) as per engineer in charge and finished smooth white agaria marble stone , phe 2 providing and fixing salem stainless steel a isi 304 ( 18 / 8 ) kitchen sink as per is: 13983 with ci brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required. kitchen sink with drain board510x1040mm bowl depth 200mm. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing:rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixturescomplete, including cutting and making good the walls andlevel whitep.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings andfloors wherever required :white vitreous china orissa pattern w.c. pan of size580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 9 providing and fixing cp brass 32mm size bottle trap of approved quality & make and as per the direction of engineer in charge.. ( sink & urinal ) , phe 10 providing & fixingptmt towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealedfittings arrangement of approved quality and colour weighing not less than 88 gms , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size 660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 15 providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water ( 250 ml & 500 ml consumption ) , having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of engineer in charge.. , phe 16 providing & fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. , phe 17 providing and fixing white vitreous china laboratory sink with c.i. brackets, c.p. brass chain with rubber plug, 40 mm c.p brass waste and 40mm c.p. brass trap with necessary c.p. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required :size 600x450x200 mm , phe 18 providing and fixing cp brass single lever telephonic wall mixer of quality & make as approved by engineer in charge . a ) 15 mm nominal dia. , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 21 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 24 two or more coats on new work over an under coat ofsuitable shade with ordinary paint of approved brand andmanufacturetwo more coast on new work , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm.clear depth and 250mm apron including cost of e / w. involved with 75mmcement concrete ( 1:4:8 ) over one brick designation 100 a flat soling inproper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 8 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia. exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 11 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 450 mm dia rcc pipe , ex. phe 12 inside size 120x90 cm and 90 cm deep including c.i. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg ) :with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , ex. phe 13 providing and fixing square mouth sw gully trap grade ‘a’ complete ci grating brick masonry chamber with bricks of class designation 75 and water tight ci cover with frame of 300 x 300 mm size ( inside ) the weight of cover to be not less than 13.00 kg and frame to be not less than 5 kg. as per standard design. ( cover min. 4.5 kg & frame min.2.7 kg ) 180x150 mm size p type with fps bricks , ex. phe 14 constructing masonry chamber 30x30x50 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement:4 coarce sand ) for stop cock complete with c.i. surface box 100x100x75mm ( inside ) with locking arrangement and rcc top slab 1:2:4 mix ( 1 cement : 2 corase sand: 4 graded stonr aggregate 20mm nominal size ) necessary excavation foundation concret 1:5:10 ( 1 cement:5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortor 1:3 ( 1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design. , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , ex. phe 16 structual steel work welded in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. , ex. phe 17 making connection of gi distribution branch with gi main of 50 80mm nominal bore by providing and fixing tee, including cutting and threading the pipe etc. complete. , rain water harvesting 1 boring / drilling bore well of required dia for casing / strainer pipe, bysuitable method prescribed in is:2800 ( part i ) , including collecting sample from different strata , preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90m depth below ground level.300 mm dia , rain water harvesting 2 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150mm nominal size dia , rain water harvesting 3 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well screen ( rms ) pipes with ribs, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150 mm nominal size dia , rain water harvesting 4 supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 5 supplying, filling, spreading & levelling gravel of size range 5mm to 10mm, in recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 7 providing and fixing bail plug / bottom plug of required dia to the bottom of pipe assembly of tube well as per is:2800 ( part i ) . 100 mm dia , rain water harvesting 8 making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and s.w. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , rain water harvesting 9 constructing soak pit 1.20x1.20x1.20 m filled with brickbats including s.w. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , tubewell 1 boring / drilling bore well of required dia for casing / strainer pipe, bysuitable method prescribed in is:2800 ( part i ) , including collecting sample from different strata , preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90m depth below ground level.300 mm dia , tubewell 2 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150mm nominal size dia , tubewell 3 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.100mm nominal size dia , tubewell 4 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well screen ( rms ) pipes with ribs, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.100 mm nominal size dia , tubewell 5 supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , tubewell 6 providing and fixing bail plug / bottom plug of required dia to the bottom of pipe assembly of tube well as per is:2800 ( part i ) . 100 mm dia , submersible pump 35m deep boring with casing and pipe. supply of pipe etc supplying & installation of suitable 2hp submersible pump b.s or k.s.bor equivalent make with finolex cable 1x3x2.5 squmm ( upto 50mtr ) withflexible conduit 25mm dia, electrical out door pannel with required electrical fitting such as mcb of 0 25amp ( havell or indocopp or mds make ) , volt & ampere meter ( ae make ) , single phase preventer ( minilac or vsp 1 make ) starter ( l&t or bch make ) etc of approved make, 40mm hdpe pipe ( 25 mtr ) and all accessories complete as per requirement of site. , water purifier and cooler 1 fitting and fixing single faucet storage type water cooler ( size 461 mm wide x 582 mm deep x 1217 mm height, weight 46 kg ) fully stainless body having storage capacity of 40 ltrs, cooling capacity of 40 ltrs. / hr. with hermetic type compressor, gas cooled motor equipped with over load protector, condensor for propeller type, thermostat autometically controlled temperature, refrigerent r 22, 230 volt, single phase 50 hertz, maximum current 2.3 amp including plug top and electrical lead wire connection upto 3 metres from the cooler, water inlet and drain out connections complete in all respects of voltas model no 40 / 40 tushar pss type or similar type of approved make. , water purifier and cooler 2 fitting and fixing water purifier for drinking purpose of capacity 6 litres / min, 5 purification system with reverse osmosis system with ultra ventilated membrane, tds500 to 2000 mgl / ppm, auto shut off with microswitch float manual flush facility, tds reduction 90% having automatic backwash system with filteration unit along with all accessories including plug top and electrical lead wire connection upto 3 metres from the purifier, water inlet and drain out connections complete in all respects similar to aquaguard or similar approved make ( model aquasure elegant ro water purifier of size width 360 mm x height 430 mm x depth 235 mm and weight 8.5 kg ) . , fire extinguisher 1 providing and fixing carbon di oxide type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. capacity 4.5 kg. , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 6.0 kg. , electrical 1 wiring for light point / fan point / exhaust fan point / call bellpoint with 1.5 sq.mm frls pvc insulated copper conductorsingle core cable in surface / recessed steel conduit, withmodular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. group c , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , pvc conduit 1 supplying and fixing of following sizes of medium class 20mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , pvc conduit 2 supplying and fixing of following sizes of medium class 32mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , pvc conduit 3 supplying and fixing of following sizes of medium class 50mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , electrical 4 wiring for light / power plug with 2x4 sq. mm frls pvcinsulated copper conductor single core cable in surface / recessed conduit alongwith 1 no. 4 sq. mm frls pvcinsulated copper conductor single core cable for loop earthingas required. , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 4 x 6 sq. mm + 2 x 6 sq. mm earth wire , wiring frls pvc insulated copper conductor 4 4 x 10 sq. mm + 2 x 6 sq. mm earth wire , wiring frls pvc insulated copper conductor 5 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 1 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 3 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 4 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 2 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 3 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 4 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 5 telephone socket outlet , s / f modular switch / socket on the existing modular plate 6 tv antenna socket outlet , s / f modular switch / socket on the existing modular plate 7 bell push , electrical 5 supplying & fixing suitable size gi box wih modular plate and cover in front on surface or in recess including providing and fixing 25 a modular socket outlet and 25 a modular sp mcb, “c” curve including connections, painting etc. as required. ( for ac / geyser ) , electrical 6 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface / recessed steel / pvc conduit as required. , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 11 supplying and fixing 20 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. , electrical 12 supplying and fixing 30 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , electrical 14 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 12 way , double door , electrical 15 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 16 way, double door , electrical 16 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 6 way ( 4 + 18 ) , double door , electrical 17 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way ( 4 + 24 ) , double door , electrical 18 supplying and fixing of following ways surface / recess mounting, vertical type, 415 v, tpn mcb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 a tinned copper bus bar, common neutral link, earth bar, din bar for mounting mcbs ( but without mcbs and incomer ) as required . ( note : vertical type mcb tpdb is normally usedwhere 3 phase outlets are required. ) 4 way ( 4 + 12 ) , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 63a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 100a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , l / f pvc sheathed / xlpe power cable in trench laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 95 sq. mm and upto 185 sq. mm , l / f pvc sheathed / xlpe power cable in trench 1 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 185 sq. mm and upto 400 sq. mm , l / f pvc sheathed / xlpe power cable over cable tray upto 35 sq. mm ( clamped with 1mm thick saddle ) , l / f pvc sheathed / xlpe power cable over cable tray 2 above 35 sq. mm and upto 95 sq. mm ( clamped with 25x3mm ms flat clamp ) , l / f pvc sheathed / xlpe power cable over cable tray 3 above 95 sq. mm and upto 185 sq. mm ( clamped with 25 / 40x3mm ms flat clamp ) , l / f pvc sheathed / xlpe power cable over cable tray 4 above 185 sq. mm and upto 400 sq. mm ( clamped with 40x3mm ms flat clamp ) , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 3.5c x 300 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 1 3.5c x 240 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 2 3.5c x 120 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 3 3.5c x 95 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 4 3.5c x 50 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 5 4c x 35 sqmm aluminium conductor cable a2xfy , cable tray supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 100 mm width x 50 mm depth x 1.6 mm thickness , cable tray 1 supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 300 mm width x 50 mm depth x 1.6 mm thickness , cable tray 2 supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 600 mm width x 62.5 mm depth x 2.0 mm thickness , cable tray “bends” supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.100 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 1 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.150 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 2 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.300 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 3 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.450 mm width x 50 mm depth x 2 mm thickness , cable tray “bends” 4 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.600 mm width x 62.5 mm depth x 2.0 mm thickness , mv cable supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 300 sqmm, aluminium conductor cable a2xfy , mv cable 1 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 240 sqmm, aluminium conductor cable a2xfy , mv cable 2 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 120 sqmm, aluminium conductor cable a2xfy , mv cable 3 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 95 sqmm, aluminium conductor cable a2xfy , earthing earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 1 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. , earthing 2 earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. , earthing 3 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 4 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , earthing 5 providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required. , earthing 6 providing and fixing earth bus of 50 mm x 5 mm copper strip on surface for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 4 supplying and fixing recess mounted 12 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 6 supply, installation, testing and commissioning of 400 mm sweep, 65w, blade material aluminium blades , speed & oscillation 3 speed, pull cord for speed and oscillation.air delivery minimum 72 m³ / min, speed minimun 1350 revolution per minute.suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , fiting & fixtures 8 supplying installation testing & commissioning ofb22 based 9w led 3 star bulb with 850 lumen, 6k color temperature including holder. , fiting & fixtures 9 supplying installation testing & commissioning of black painted extruded aluminium housing. green / red led’s mounted inside the housing. laser engraved signage matter on single / double acrylic sheet fixed on one side suitable for wall / ceiling / suspension type single / double sided display. in double sided version black paper is inserted. ni cd battery back up to 2 hrs. ( charged up to 8 10 hrs ) .mounting strings provided for pendent mounting operating voltage 150 280v ac ambient operating temperature. – 0 to 450c ingress protection – ip42.including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required.   220208 besl 03 led ssd wbb green 240 3 8wor220209 besl 03 led ssd wbb red 240 3 8wor220210 besl 03 led dsd wbb green 240 3 8wor220211 besl 03 led dsd wbb red 240 3 8w , fiting & fixtures 10 supply, installation, testing & erecting of ip66 bulkhead surface type lighting fixture 10w made up of pressure die cast aluminium housing and polyster powder coated die cast aluminium with high quality polycarbonate diffuser in opal finish for glare free light distribution.high efficiency long life led module with smd led package mounted on mcpcb with lumen efficacy of >95 lm / w with system lumen 950. powered by integral electronic led driver with apfc with low thd output short / open circuit protection. cct 5700, cri>80, system efficacy>90lm / w, thd<15%, pf>.95, ip66, ik 10, life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz.including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. cat ref: havells : hexaft10wled857ssymbopc or approved equivalent. , civil & misc works1 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. , civil & misc works2 providing and fixing h.t. danger notice plate of 250 mm x 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. , civil & misc works3 supplying and making cable route marker with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm x 60 cm at the bottom and 50 cm x 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. , civil & misc works4 supplying and fixing cable route marker with 10 cm x 10 cm x 5 mm thick g.i. plate with inscription there on, bolted / welded to 35 mm x 35 mm x 6 mm angle iron, 60 cm long and fixing the same in ground as required. , civil & misc works5 providing & fixing in position 1000 mm wide , electrical insulating rubber mats as per is 15652:2006, 2 mm thick, suitable up to 1.1 kv , fire retardant, no effect of acids, alkalis and transformer oils, moisture proof, high tensile strengthandtexture finish / cloth impression ( anti slip , marking on top ) , civil & misc works6 supply & fixing shock treatment chart duly mounted on a wooden frame with 5 mm thick glass as required ( approx front area 1.20 sq metre ) , 40 kvaups supplying, installation, testing and commissioningof online double conversion fully microprocessor based , indoor type, compact ups system of following rating with igbt based pwm technology to achieve thd < 3% and input power factor of greater than 0.95 at 50% loading, suitable for three phase ac input voltage 380 v to 440 v, 50 hz +3% / 3 % and three phase ac output voltage 415 ± 1% volts & frequency 50 ± 0.5 hz , inbuilt isolation transformer, necessary vrla batteries of suitable size having 30 minutes back up time , mounting rack including and suitable size connecting cable ( for ups to battery and battery to battery ) , static and maintenance bypass switch, snmp card for rs232 / ethernet ip computability for operation and monitoring etc. with all components as mentioned , specifications, complete as required.note : concerning vendor needs to furnish the battery sizing calculations at the time of ga approval and battery size has to be as per the approved ga drawing. , external lighting 1 supply and erection of 4 metre height hot dipgalvanized octagonal street light pole with followingarm with top dia 70 mm and bottom dia a / f 130 mm, made of 3 mm thick sheet along with base plate of size220 x 220 x 12 mm , small door opening for junctionbox mounting with mcb & connector, cement concreteof 1:3:6 including excavation, refilling and suitable sizefoundation bolts with template and all complete jobasrequired. ( but without pole collar ) single arm , external lighting 2 supplying and fixing 40 / 45 watt led type street lightwith die cast aluminium housing for ingress protectionof ip65 and complete with all accessories etc, onpole / building including connection with fr pvcinsulated copper conductor cable and earthing thebody etc. as required. , ip based cctv system 1 sitc of 2 megapixel @ 25fps, h.265 ip bullet camera, 1 / 2.9 cmos with 2.8~12mm varifocal lens, 0 lux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 2 sitc of 2 megapixel @ 25fps, h.265 ip dome camera, 1 / 2.9 cmos with 3.6 fixed mm 0 lux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 3 sitc of 2 megapixel @ 25fps, ptz camera h.265 ip dome camera, 1 / 2.9 cmos with 2.6 fixed lenslux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 4 sitc of 32ch 4k ivr , h.265 / h.264 • 1080p real time • 4k display • dual lan • 8x hdd • raid •web plugin free h.265 / h.264 compression technology 4k display for clear monitoring up to 1080p 16ch decoding ability smart search ii smart vca event searchsupport raid 0, 1, 5 supported to prevent from recording data loss browsers supported: ie , smart functions : target count, electric fence, face detection, humaniod detection, retrograde detection, leave position detectio output, local & network backup etc. complete as required. , cctv 5 sitc of harddiskdrive8tb, 24 / 7surveillance category only complete etc as required.etc.all complete , cctv 6 sitc of 55 led narrow bazel for monitoring for nvr server etc. all complete. , cctv 7 sitc of rj 45 outlets near the cameras etc. all complete. etc. all complete. , cctv 8 sitc of cat 6 patch cords 1 meter high quality four pair twisted stranded cable terminated with rj45 modular plugs at both the ends. , signage 1 providing & fixing of building direction signage mounted on pole, with pole of 100x100mm shs ( square hollow section ) of height of 5600mm, and sign size of 900x1050, sign made of aluminiu c section of 60mm with internal framing to support the frame in ms tubes hollow section, frame work duly painted with anti rust coatings, with facia of 3mm thick exterior grade aluminium composite panel, cladded with uv cured digital printed retroreflective sheet of 3m make, and back panel of 3mm exterior grade acp, all pipes to be painted in approved color. cost shall includecost towards installation, including excuvation and filling up with specified pcc and fixing of foundation bolts as specified, also it shall include the designing charges.all complete as per direction by engineer in charge. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , 2 tr air conditioning 1 split ac ( inverter model ) : supply, installation, testing, commissioning of split type wall mounted air conditioning units of following capacity including inddor, outdoor unit fitted with inverter based rotary compressor fitted with rotary compressor, copper condensor and first charge refrigent r410a / eco friendly green gas only, all complete including all electrical connections to the electrical power supply system of the building, includingbut not limited to supply of all electrical plugs, etc., as necessary, lengthening of all electrical wires of ac units ( both indoor and outdoor ) , drain pipe andincluding suitable voltage stabilisers, etc. so as to place them in a concealed manner in the desired position. the copper pipes and electrical cables shall be concealed in approved manner and neatly run in straight lines in a workman like manner with proper supports. complete supply and installation of split2 tr star rating 3 star , refrigerant piping copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 25 mm od, wall thickness >= 1.2 mm ( insulation 19 mm thick ) , refrigerant piping 1 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 19.1 mm od, wall thickness >= 1.0 mm ( insulation 13 mm thick ) , refrigerant piping 2 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 15.9 mm od, wall thickness >= 0.8 mm ( insulation 13 mm thick ) , refrigerant piping 3 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 9.5 mm od, wall thickness >= 0.8 mm ( insulation 13 mm thick ) , drain piping providing and fixing of cpvc 6 kg / cm2 drainpiping complete with fittings, supports, 6 mm thick closed cell elastomeric insulation as per specifications and drawings. 20 mm , drain piping 1 providing and fixing of cpvc 6 kg / cm2 drainpiping complete with fittings, supports, 6 mm thick closed cell elastomeric insulation as per specifications and drawings. 32 mm , main oxygen manifold supply, installation, testing and commissioning of following gas manifold system ( excluding cylinders ) . the manifold is configured for designed numbers of cylinders and is suitable to withstand a pressure of 145 kg / cm2, along withhigh pressure copper annealed tail pipes with end brass adapter suitable for cylinders and manifold. top frame comprising of high pressure copper pipes of size 1 / 2” nb x 15swg with high pressure brass fittings made of high tensile brass and connections through nonreturn valves, the design of middle and bottomframes is provided to fit both round and flat bottom cylinders safely. the manifold is tested ( hydraulically ) at 3500 psig. ( it should be ce and iso 13485 certified ) mani fold oxygen manifold 6 + 6 cylinder banks complete with nrv, middle frame, bottom frame with ce marked, , emergency manifold emergency oxygen manifold 01 + 01 cylinder emergency manifold with complete regulator, nrv, middle frame & bottom frame, , control panelfor oxygen fully automatic three port control panel for oxygen supply, installation, testing and commissioning of automatic manifold control panel would provide a duty or standby gas supply from two cylinder banks with automaticchangeover the manifold indicates local status and has a remote indicator facility. automaticmanifold control panel would be designed to supply the mgps with a constant pressure supply via a control panel form two equal banks of cylinders and the changeover from the ‘duty’ to the ‘standby’ bank of cylinders would beautomatic. automatic changeover from the duty to the standby bank would occur at a cylinder pressure that will ensure the maximum usage of the contents of the duty bank. the changeover unit would be provided with monitoring todetect and display: duty bank operating, duty bank empty, standby bank operating, and standby bank below 10 % when the duty bank is empty, reserve bank low, pipeline pressure fault. there would be facility to connect liquidoxygen supply ( i.e. three port control panel ) ( it should be ce and iso 13485 certified ) fully automatic three port control panel for oxygen , emergency manifold line regulator emergency manifold line regulator supply, installation, testing and commissioning of emergency manifold line regulator i n p u t p r e s s u r e 1 5 0 k g / c m 2 working pressure 4 kg / cm2 it should be ce and iso 13485 certified.oxygen input pressure 150 kg / cm2 working pressure 4 kg / cm2capacity : 1500 lpm , cylinderconnectingpipe ( pig tail ) supply, installation, testing and commissioning of cylinder connecting pipe ( pig tail ) made up of flexible ss hose with safety cord 5 / 8 inch bsp gland nut and one side 1 / 2 inch bsp internal threads having one meter length. ( oxygen 24 , n2o 10, co2 4 ) , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , medical air ( 4 bar ) outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve, supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified.42mm , isolation valve 2 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 28mm , isolation valve 3 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 22mm , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness , pipeline 4 medical grade copper pipeline ( in mtrs. ) as per en 13348, 28 mm ( od ) x 0.9 mm thickness , pipeline 5 medical grade copper pipeline ( in mtrs. ) as per en 13348, 42 mm ( od ) x 1.2 mm thickness , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 2268 mm x ( w ) 922 mm x ( h ) 610 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , paediatric bed with mattress paediatric bed of overall sizes in mm: 1500 ( l ) x 850 ( w ) x 1210 ( h ) flat single section bed with grille frame on 4 sides.suitable for children up to 12 years.drop down grill frame on both sides for protection of the patient.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral white , bed side locker type i over all dimension :402mmlx422mm wx840mm ht .locker should have one cabinet and one drawer unit .both provided with cam lock .there should be gap between drawer and unit to keep general items for frequesnt use castors are provided for easy handling .drawer made up of crca sheet 1 mm thick and has ball slide for easy operation .top ss 304 sheet 0.8 mm thick castors 50 mmdia , hamdle abs ..powder coating of epoxy polyester , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , strecher on trolley type i 2005mm ( l ) x666mm ( w ) x827mm ( h ) .the trolley should be made of 31.75 and 25.4 mm dia 1.6 mm thick erw tube.holder for stretcher should be made up of mild steel.castor should be of 200 mm dia , diagonal locking castor.stretcher should be made up oferw tubeof dia 25.4 mm and thickness 1.6 mm.top sheet should be made of crca sheetof thickness 1.2 mm with contour shape to accommodate patient.iv pole holder should be made ofms .maximum safe work load should be 135 kg.to ensure qood quality welding co2 argonprocess should be adhered to.all metal componentsshould be pre treated with zinc phosphating in 9 tank porcess and then powder coated with anti microbialepoxy polyster powder coating.goods should be supplied in knocked down construction to reduce carbon emission. performance test :proof loading test , cycle tests , impact test, salt spray test, castor break test, the manufacturer should compilant with iso 9001, 14001, 13485, ohsas 1800 and ce certification. , doctor desk type x s / f / f executive table main desk should be of dimesion : 1350w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. side panels : ( black ) made form 18mm thick plt with pvc lipping.modesty panel : made form 18mm thick plt with pvc lipping. bigger upper panel in black and smaller lower panel in white cedar. made from 18mm thick plt with pvc lipping. mobile pedestal : one box and one filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , chair type iii s / f / f executive chair1 ) seat / back assembly: the seat and back are made up of 1.2 cm. thick hot pressed plywood, upholstered withfabric upholstery covers and moulded polyurethane foam. the back foam is designed with contoured lumbar support for extra comfort. the seat has extra thick foam on front edge to give comfort to popliteal area.high back size : 47.5 cm ( w ) x 69.5 cm ( h ) seat size : 47.0 cm. ( w ) x 48.0 cm. ( d ) 2 ) polyurethane foam: the polyurethane foam is moulded with density = 45 + / 2 kg / m 3and hardness = 20 + / 2at 25% compression. 3 ) armrests: the one piece armrests are injection moulded from black co polymer polypropylene. 4 ) center tilt synchro mechanism : the mechanism is designed with the following features:• 360 revolving type. • upright position locking. • tilt tension adjustment.• seat / back tilting ratio of 1:3 ( 60 seat tilt / 180 back tilt ) . 5 ) pneumatic height adjustment : the pneumatic height adjustment has anadjustment stroke of 12.0 cm. 6 ) telescopic bellow assembly : the bellow is 3 piece telescopic type and injection moulded in black polypropylene. 7 ) pedestal assembly : . , staff / visitor chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck .3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement.mx load bearing capacity should be 10 kg. , hospital curtain tracks & i.v. tree system supply installation testing & commissioning of cubical tracks system made of powder coated aluminium alloy, stain free polyster fabric , water repellent curtains , smooth movement , non sticking runnner with stainless steel hooks made from mirror finish stainless steel , adjustable height with all accessories. total quantity : 1...

Health And Family Welfare Department - Bihar

30458765 bids are invited for pile boring, providing and installation bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using direct mud circulation ( dmc ) or bailer and chisel technique by tripod and mechanical winch machine all complete, including removal of excavated earth with all its lifts and leads ( length of pile for payment shall be measured up to bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , upvc door providing and fixing of factory made upvc white colour casement door, upvc multichambered extruted frame, sash and mullion profile. frame duly reinforced with 1.2mm gi section box tpe chamber and sash with 1.5mm thick gi section ( ± 0.2mm ) based on wind load calculations ( shape and size according to upvc profiles ) , appropiate dimentions of upvc extruded glazing bead, epdm gasket ( k / o type ) , seperate drainage system, ss34 grade friction hinges 2d / 3d plate hinges, zinc alloy ( white powder coated ) casement handle, gi fastener 8x100 mm size for fixing frame to finish wall, plastic packer and caps and necessary steel screws etc.profile of frame and sash shall be metered cut and fusion welded at all corners, mullion shall be also fusion welded / joined mechanically including drilling of holes for fixing hardware and drainage of water etc. after fixing of frames , gap between frame and adjascent wall shall be filled with pu foaam / backer rod required size and the approved quantity. after that sealed with weather proof silicon sealant at both side, all complete as per approved drawing and direction of eic , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 1 providing and laying vitrified floor tiles in different sizes ( thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including grouting the joints with white cement and matching pigments etc., complete. size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge :flamed finish granite stone slab jet black, cherry red, elitebrown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item ( galvanised@80gsm ) 50 mm long 8mmouter diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’ , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975. the wind load shall be as per provisions of is 875 ( part iii ) . lgsfs frame shall be designed as per is: 801 using commercially available software such as frame cad pro 11.7 / staad pro v8i / architekv2.5.16 / revit architecture 2011 or equivalent. proper usage of connection accessories like heavy duty tension ties, light duty hold ons, twist straps ( to connect truss with wall frames ) , strong tie, tie rod, h brackets, boxing sections, l shaped angles for better structural stability. the framing section shall be cold form c type having minimum web depth 89 mm x 39mm flange x 11mm lip in required length as per structural design requirement duly punched with dimple / slot at required locations as per approved drawings. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm and. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , face panel providing and fixing in all exterior face panels breathable vapour barrier underneath the cementfiber board as per national building code 2009 complete as per direction of engineer in charge. , lap siding supplying and installation of moisture resistant / fire resistantlap siding 8 mm thick and width as per standard sizes made ofiber cement board with embossed decorative finish to give pleasing exterior fixed horizontally with staggered joints including minimum over lapof 32 mm external cement fibre boardconforming to is 14862:2000 offixed with self drilling / taping screws / fastners of approved make. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1 new work ( two or more coats ) over and including water tinnable priming coat with cement primer , ex. paint finishing walls with textured exterior paint of required shade : new work ( two or more coats applied @ 3.28 ltr / 10 sqm ) over and including priming coat of exterior primer applied @ 2.20kg / 10 sqm sqm , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel 1 steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , road providing and laying c.c. pavement of mix m 25 with ready mixed concrete from batching plant. the ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc.complete as per specifications and directions of engineer in charge. ( the panel shuttering work shall be paid for separately ) . ( note: cement content considered in this item is @ 330 kg / cum. excess / less cement used as per design mix is payable / recoverableseparately ) . , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 1 providing & fixing stone slab table rubbed, edges rounded and polished of size 75 x 50cm deep and 1.8 cm thick fixed in urinal patitions by cutting chase of appropriate width with chase cutter and embedding the stone in chase with epoxy grout or with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregste 6mm nominal size ) as per engineer in charge and finished smooth white agaria marble stone , phe 2 providing and fixing salem stainless steel a isi 304 ( 18 / 8 ) kitchen sink as per is: 13983 with ci brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required. kitchen sink with drain board510x1040mm bowl depth 200mm. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing:rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixturescomplete, including cutting and making good the walls andlevel whitep.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings andfloors wherever required :white vitreous china orissa pattern w.c. pan of size580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 9 providing and fixing cp brass 32mm size bottle trap of approved quality & make and as per the direction of engineer in charge.. ( sink & urinal ) , phe 10 providing & fixingptmt towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealedfittings arrangement of approved quality and colour weighing not less than 88 gms , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size 660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 15 providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water ( 250 ml & 500 ml consumption ) , having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of engineer in charge.. , phe 16 providing & fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. , phe 17 providing and fixing white vitreous china laboratory sink with c.i. brackets, c.p. brass chain with rubber plug, 40 mm c.p brass waste and 40mm c.p. brass trap with necessary c.p. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required :size 600x450x200 mm , phe 18 providing and fixing cp brass single lever telephonic wall mixer of quality & make as approved by engineer in charge . a ) 15 mm nominal dia. , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 21 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 24 two or more coats on new work over an under coat ofsuitable shade with ordinary paint of approved brand andmanufacturetwo more coast on new work , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm.clear depth and 250mm apron including cost of e / w. involved with 75mmcement concrete ( 1:4:8 ) over one brick designation 100 a flat soling inproper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 8 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia. exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 11 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 450 mm dia rcc pipe , ex. phe 12 inside size 120x90 cm and 90 cm deep including c.i. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg ) :with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , ex. phe 13 providing and fixing square mouth sw gully trap grade ‘a’ complete ci grating brick masonry chamber with bricks of class designation 75 and water tight ci cover with frame of 300 x 300 mm size ( inside ) the weight of cover to be not less than 13.00 kg and frame to be not less than 5 kg. as per standard design. ( cover min. 4.5 kg & frame min.2.7 kg ) 180x150 mm size p type with fps bricks , ex. phe 14 constructing masonry chamber 30x30x50 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement:4 coarce sand ) for stop cock complete with c.i. surface box 100x100x75mm ( inside ) with locking arrangement and rcc top slab 1:2:4 mix ( 1 cement : 2 corase sand: 4 graded stonr aggregate 20mm nominal size ) necessary excavation foundation concret 1:5:10 ( 1 cement:5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortor 1:3 ( 1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design. , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , ex. phe 16 structual steel work welded in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. , ex. phe 17 making connection of gi distribution branch with gi main of 50 80mm nominal bore by providing and fixing tee, including cutting and threading the pipe etc. complete. , rain water harvesting 1 boring / drilling bore well of required dia for casing / strainer pipe, bysuitable method prescribed in is:2800 ( part i ) , including collecting sample from different strata , preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90m depth below ground level.300 mm dia , rain water harvesting 2 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150mm nominal size dia , rain water harvesting 3 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well screen ( rms ) pipes with ribs, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150 mm nominal size dia , rain water harvesting 4 supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 5 supplying, filling, spreading & levelling gravel of size range 5mm to 10mm, in recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 7 providing and fixing bail plug / bottom plug of required dia to the bottom of pipe assembly of tube well as per is:2800 ( part i ) . 100 mm dia , rain water harvesting 8 making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and s.w. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , rain water harvesting 9 constructing soak pit 1.20x1.20x1.20 m filled with brickbats including s.w. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , tubewell 1 boring / drilling bore well of required dia for casing / strainer pipe, bysuitable method prescribed in is:2800 ( part i ) , including collecting sample from different strata , preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90m depth below ground level.300 mm dia , tubewell 2 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150mm nominal size dia , tubewell 3 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.100mm nominal size dia , tubewell 4 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well screen ( rms ) pipes with ribs, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.100 mm nominal size dia , tubewell 5 supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , tubewell 6 providing and fixing bail plug / bottom plug of required dia to the bottom of pipe assembly of tube well as per is:2800 ( part i ) . 100 mm dia , submersible pump 35m deep boring with casing and pipe. supply of pipe etc supplying & installation of suitable 2hp submersible pump b.s or k.s.bor equivalent make with finolex cable 1x3x2.5 squmm ( upto 50mtr ) withflexible conduit 25mm dia, electrical out door pannel with required electrical fitting such as mcb of 0 25amp ( havell or indocopp or mds make ) , volt & ampere meter ( ae make ) , single phase preventer ( minilac or vsp 1 make ) starter ( l&t or bch make ) etc of approved make, 40mm hdpe pipe ( 25 mtr ) and all accessories complete as per requirement of site. , water purifier and cooler fitting and fixing single faucet storage type water cooler ( size 461 mm wide x 582 mm deep x 1217 mm height, weight 46 kg ) fully stainless body having storage capacity of 40 ltrs, cooling capacity of 40 ltrs. / hr. with hermetic type compressor, gas cooled motor equipped with over load protector, condensor for propeller type, thermostat autometically controlled temperature, refrigerent r 22, 230 volt, single phase 50 hertz, maximum current 2.3 amp including plug top and electrical lead wire connection upto 3 metres from the cooler, water inlet and drain out connections complete in all respects of voltas model no 40 / 40 tushar pss type or similar type of approved make. , water purifier and cooler 1 fitting and fixing water purifier for drinking purpose of capacity 6 litres / min, 5 purification system with reverse osmosis system with ultra ventilated membrane, tds500 to 2000 mgl / ppm, auto shut off with microswitch float manual flush facility, tds reduction 90% having automatic backwash system with filteration unit along with all accessories including plug top and electrical lead wire connection upto 3 metres from the purifier, water inlet and drain out connections complete in all respects similar to aquaguard or similar approved make ( model aquasure elegant ro water purifier of size width 360 mm x height 430 mm x depth 235 mm and weight 8.5 kg ) . , fire extinguisher 1 providing and fixing carbon di oxide type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. capacity 4.5 kg. , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 6.0 kg. , electrical 1 wiring for light point / fan point / exhaust fan point / call bellpoint with 1.5 sq.mm frls pvc insulated copper conductorsingle core cable in surface / recessed steel conduit, withmodular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. group c , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , pvc conduit 1 supplying and fixing of following sizes of medium class 20mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , pvc conduit 2 supplying and fixing of following sizes of medium class 32mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , pvc conduit 3 supplying and fixing of following sizes of medium class 50mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , electrical 4 wiring for light / power plug with 2x4 sq. mm frls pvcinsulated copper conductor single core cable in surface / recessed conduit alongwith 1 no. 4 sq. mm frls pvcinsulated copper conductor single core cable for loop earthingas required. , wiring frls pvc insulated copper conductor 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 1 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 2 4 x 6 sq. mm + 2 x 6 sq. mm earth wire , wiring frls pvc insulated copper conductor 3 4 x 10 sq. mm + 2 x 6 sq. mm earth wire , wiring frls pvc insulated copper conductor 4 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 1 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 3 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 4 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 1 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 2 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 3 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 4 telephone socket outlet , s / f modular switch / socket on the existing modular plate 5 tv antenna socket outlet , s / f modular switch / socket on the existing modular plate 6 bell push , electrical 5 supplying & fixing suitable size gi box wih modular plate and cover in front on surface or in recess including providing and fixing 25 a modular socket outlet and 25 a modular sp mcb, “c” curve including connections, painting etc. as required. ( for ac / geyser ) , electrical 6 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface / recessed steel / pvc conduit as required. , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 11 supplying and fixing 20 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. , electrical 12 supplying and fixing 30 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , electrical 14 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 12 way , double door , electrical 15 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 16 way, double door , electrical 16 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 6 way ( 4 + 18 ) , double door , electrical 17 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way ( 4 + 24 ) , double door , electrical 18 supplying and fixing of following ways surface / recess mounting, vertical type, 415 v, tpn mcb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 a tinned copper bus bar, common neutral link, earth bar, din bar for mounting mcbs ( but without mcbs and incomer ) as required . ( note : vertical type mcb tpdb is normally usedwhere 3 phase outlets are required. ) 4 way ( 4 + 12 ) , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 63a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 100a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , l / f pvc sheathed / xlpe power cable in trench laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 95 sq. mm and upto 185 sq. mm , l / f pvc sheathed / xlpe power cable in trench 1 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 185 sq. mm and upto 400 sq. mm , l / f pvc sheathed / xlpe power cable over cable tray 2 upto 35 sq. mm ( clamped with 1mm thick saddle ) , l / f pvc sheathed / xlpe power cable over cable tray 3 above 35 sq. mm and upto 95 sq. mm ( clamped with 25x3mm ms flat clamp ) , l / f pvc sheathed / xlpe power cable over cable tray 4 above 95 sq. mm and upto 185 sq. mm ( clamped with 25 / 40x3mm ms flat clamp ) , l / f pvc sheathed / xlpe power cable over cable tray 5 above 185 sq. mm and upto 400 sq. mm ( clamped with 40x3mm ms flat clamp ) , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 3.5c x 300 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 1 3.5c x 240 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 2 3.5c x 120 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 3 3.5c x 95 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 4 3.5c x 50 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 5 4c x 35 sqmm aluminium conductor cable a2xfy , cable tray 1 supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 100 mm width x 50 mm depth x 1.6 mm thickness , cable tray 2 supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 300 mm width x 50 mm depth x 1.6 mm thickness , cable tray 3 supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 600 mm width x 62.5 mm depth x 2.0 mm thickness , cable tray “bends” supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.100 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 1 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.150 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 2 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.300 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends”3 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.450 mm width x 50 mm depth x 2 mm thickness , cable tray “bends” 4 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.600 mm width x 62.5 mm depth x 2.0 mm thickness , mv cable supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 300 sqmm, aluminium conductor cable a2xfy , mv cable 1 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 240 sqmm, aluminium conductor cable a2xfy , mv cable 2 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 120 sqmm, aluminium conductor cable a2xfy , mv cable 3 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 95 sqmm, aluminium conductor cable a2xfy , earthing 1 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 2 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. , earthing 3 earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. , earthing 4 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 5 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , earthing 6 providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required. , earthing 7 providing and fixing earth bus of 50 mm x 5 mm copper strip on surface for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : , fiting & fixtures 4 supplying and fixing recess mounted 12 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 6 supply, installation, testing and commissioning of 400 mm sweep, 65w, blade material aluminium blades , speed & oscillation 3 speed, pull cord for speed and oscillation.air delivery minimum 72 m³ / min, speed minimun 1350 revolution per minute.suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , fiting & fixtures 8 supplying installation testing & commissioning ofb22 based 9w led 3 star bulb with 850 lumen, 6k color temperature including holder. , fiting & fixtures 9 supplying installation testing & commissioning of black painted extruded aluminium housing. green / red led’s mounted inside the housing. laser engraved signage matter on single / double acrylic sheet fixed on one side suitable for wall / ceiling / suspension type single / double sided display. in double sided version black paper is inserted. ni cd battery back up to 2 hrs. ( charged up to 8 10 hrs ) .mounting strings provided for pendent mounting operating voltage 150 280v ac ambient operating temperature. – 0 to 450c ingress protection – ip42.including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required.   220208 besl 03 led ssd wbb green 240 3 8wor220209 besl 03 led ssd wbb red 240 3 8wor220210 besl 03 led dsd wbb green 240 3 8wor220211 besl 03 led dsd wbb red 240 3 8w , fiting & fixtures 10 supply, installation, testing & erecting of ip66 bulkhead surface type lighting fixture 10w made up of pressure die cast aluminium housing and polyster powder coated die cast aluminium with high quality polycarbonate diffuser in opal finish for glare free light distribution.high efficiency long life led module with smd led package mounted on mcpcb with lumen efficacy of >95 lm / w with system lumen 950. powered by integral electronic led driver with apfc with low thd output short / open circuit protection. cct 5700, cri>80, system efficacy>90lm / w, thd<15%, pf>.95, ip66, ik 10, life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz.including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. cat ref: havells : hexaft10wled857ssymbopc or approved equivalent. , civil & misc works1 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. , civil & misc works2 providing and fixing h.t. danger notice plate of 250 mm x 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. , civil & misc works3 supplying and making cable route marker with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm x 60 cm at the bottom and 50 cm x 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. , civil & misc works4 supplying and fixing cable route marker with 10 cm x 10 cm x 5 mm thick g.i. plate with inscription there on, bolted / welded to 35 mm x 35 mm x 6 mm angle iron, 60 cm long and fixing the same in ground as required. , civil & misc works5 providing & fixing in position 1000 mm wide , electrical insulating rubber mats as per is 15652:2006, 2 mm thick, suitable up to 1.1 kv , fire retardant, no effect of acids, alkalis and transformer oils, moisture proof, high tensile strengthandtexture finish / cloth impression ( anti slip , marking on top ) , civil & misc works6 supply & fixing shock treatment chart duly mounted on a wooden frame with 5 mm thick glass as required ( approx front area 1.20 sq metre ) , 40 kvaups supplying, installation, testing and commissioningof online double conversion fully microprocessor based , indoor type, compact ups system of following rating with igbt based pwm technology to achieve thd < 3% and input power factor of greater than 0.95 at 50% loading, suitable for three phase ac input voltage 380 v to 440 v, 50 hz +3% / 3 % and three phase ac output voltage 415 ± 1% volts & frequency 50 ± 0.5 hz , inbuilt isolation transformer, necessary vrla batteries of suitable size having 30 minutes back up time , mounting rack including and suitable size connecting cable ( for ups to battery and battery to battery ) , static and maintenance bypass switch, snmp card for rs232 / ethernet ip computability for operation and monitoring etc. with all components as mentioned , specifications, complete as required.note : concerning vendor needs to furnish the battery sizing calculations at the time of ga approval and battery size has to be as per the approved ga drawing. , external lighting 1 supply and erection of 4 metre height hot dipgalvanized octagonal street light pole with followingarm with top dia 70 mm and bottom dia a / f 130 mm, made of 3 mm thick sheet along with base plate of size220 x 220 x 12 mm , small door opening for junctionbox mounting with mcb & connector, cement concreteof 1:3:6 including excavation, refilling and suitable sizefoundation bolts with template and all complete jobasrequired. ( but without pole collar ) single arm , external lighting 2 supplying and fixing 40 / 45 watt led type street lightwith die cast aluminium housing for ingress protectionof ip65 and complete with all accessories etc, onpole / building including connection with fr pvcinsulated copper conductor cable and earthing thebody etc. as required. , ip based cctv system 1 sitc of 2 megapixel @ 25fps, h.265 ip bullet camera, 1 / 2.9 cmos with 2.8~12mm varifocal lens, 0 lux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 2 sitc of 2 megapixel @ 25fps, h.265 ip dome camera, 1 / 2.9 cmos with 3.6 fixed mm 0 lux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 3 sitc of 2 megapixel @ 25fps, ptz camera h.265 ip dome camera, 1 / 2.9 cmos with 2.6 fixed lenslux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 4 sitc of 32ch 4k ivr , h.265 / h.264 • 1080p real time • 4k display • dual lan • 8x hdd • raid •web plugin free h.265 / h.264 compression technology 4k display for clear monitoring up to 1080p 16ch decoding ability smart search ii smart vca event searchsupport raid 0, 1, 5 supported to prevent from recording data loss browsers supported: ie , smart functions : target count, electric fence, face detection, humaniod detection, retrograde detection, leave position detectio output, local & network backup etc. complete as required. , cctv 5 sitc of harddiskdrive8tb, 24 / 7surveillance category only complete etc as required.etc.all complete , cctv 6 sitc of 55 led narrow bazel for monitoring for nvr server etc. all complete. , cctv 7 sitc of rj 45 outlets near the cameras etc. all complete. etc. all complete. , cctv 8 sitc of cat 6 patch cords 1 meter high quality four pair twisted stranded cable terminated with rj45 modular plugs at both the ends. , signage 1 providing & fixing of building direction signage mounted on pole, with pole of 100x100mm shs ( square hollow section ) of height of 5600mm, and sign size of 900x1050, sign made of aluminiu c section of 60mm with internal framing to support the frame in ms tubes hollow section, frame work duly painted with anti rust coatings, with facia of 3mm thick exterior grade aluminium composite panel, cladded with uv cured digital printed retroreflective sheet of 3m make, and back panel of 3mm exterior grade acp, all pipes to be painted in approved color. cost shall includecost towards installation, including excuvation and filling up with specified pcc and fixing of foundation bolts as specified, also it shall include the designing charges.all complete as per direction by engineer in charge. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , 2 tr air conditioning 1 split ac ( inverter model ) : supply, installation, testing, commissioning of split type wall mounted air conditioning units of following capacity including inddor, outdoor unit fitted with inverter based rotary compressor fitted with rotary compressor, copper condensor and first charge refrigent r410a / eco friendly green gas only, all complete including all electrical connections to the electrical power supply system of the building, includingbut not limited to supply of all electrical plugs, etc., as necessary, lengthening of all electrical wires of ac units ( both indoor and outdoor ) , drain pipe andincluding suitable voltage stabilisers, etc. so as to place them in a concealed manner in the desired position. the copper pipes and electrical cables shall be concealed in approved manner and neatly run in straight lines in a workman like manner with proper supports. complete supply and installation of split2 tr star rating 3 star , refrigerant piping copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 25 mm od, wall thickness >= 1.2 mm ( insulation 19 mm thick ) , refrigerant piping 1 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 19.1 mm od, wall thickness >= 1.0 mm ( insulation 13 mm thick ) , refrigerant piping 2 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 15.9 mm od, wall thickness >= 0.8 mm ( insulation 13 mm thick ) , refrigerant piping 3 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 9.5 mm od, wall thickness >= 0.8 mm ( insulation 13 mm thick ) , drain piping providing and fixing of cpvc 6 kg / cm2 drainpiping complete with fittings, supports, 6 mm thick closed cell elastomeric insulation as per specifications and drawings. 20 mm , drain piping 1 providing and fixing of cpvc 6 kg / cm2 drainpiping complete with fittings, supports, 6 mm thick closed cell elastomeric insulation as per specifications and drawings. 32 mm , main oxygen manifold supply, installation, testing and commissioning of following gas manifold system ( excluding cylinders ) . the manifold is configured for designed numbers of cylinders and is suitable to withstand a pressure of 145 kg / cm2, along withhigh pressure copper annealed tail pipes with end brass adapter suitable for cylinders and manifold. top frame comprising of high pressure copper pipes of size 1 / 2” nb x 15swg with high pressure brass fittings made of high tensile brass and connections through nonreturn valves, the design of middle and bottomframes is provided to fit both round and flat bottom cylinders safely. the manifold is tested ( hydraulically ) at 3500 psig. ( it should be ce and iso 13485 certified ) mani fold oxygen manifold 6 + 6 cylinder banks complete with nrv, middle frame, bottom frame with ce marked, , emergency manifold emergency oxygen manifold 01 + 01 cylinder emergency manifold with complete regulator, nrv, middle frame & bottom frame, , control panelfor oxygen fully automatic three port control panel for oxygen supply, installation, testing and commissioning of automatic manifold control panel would provide a duty or standby gas supply from two cylinder banks with automaticchangeover the manifold indicates local status and has a remote indicator facility. automaticmanifold control panel would be designed to supply the mgps with a constant pressure supply via a control panel form two equal banks of cylinders and the changeover from the ‘duty’ to the ‘standby’ bank of cylinders would beautomatic. automatic changeover from the duty to the standby bank would occur at a cylinder pressure that will ensure the maximum usage of the contents of the duty bank. the changeover unit would be provided with monitoring todetect and display: duty bank operating, duty bank empty, standby bank operating, and standby bank below 10 % when the duty bank is empty, reserve bank low, pipeline pressure fault. there would be facility to connect liquidoxygen supply ( i.e. three port control panel ) ( it should be ce and iso 13485 certified ) fully automatic three port control panel for oxygen , emergency manifold line regulator emergency manifold line regulator supply, installation, testing and commissioning of emergency manifold line regulator i n p u t p r e s s u r e 1 5 0 k g / c m 2 working pressure 4 kg / cm2 it should be ce and iso 13485 certified.oxygen input pressure 150 kg / cm2 working pressure 4 kg / cm2capacity : 1500 lpm , cylinderconnectingpipe ( pig tail ) supply, installation, testing and commissioning of cylinder connecting pipe ( pig tail ) made up of flexible ss hose with safety cord 5 / 8 inch bsp gland nut and one side 1 / 2 inch bsp internal threads having one meter length. ( oxygen 24 , n2o 10, co2 4 ) , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , medical air ( 4 bar ) outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve, supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified.42mm , isolation valve 2 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 28mm , isolation valve 3 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 22mm , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness , pipeline 4 medical grade copper pipeline ( in mtrs. ) as per en 13348, 28 mm ( od ) x 0.9 mm thickness , pipeline 5 medical grade copper pipeline ( in mtrs. ) as per en 13348, 42 mm ( od ) x 1.2 mm thickness , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 2268 mm x ( w ) 922 mm x ( h ) 610 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , paediatric bed with mattress paediatric bed of overall sizes in mm: 1500 ( l ) x 850 ( w ) x 1210 ( h ) flat single section bed with grille frame on 4 sides.suitable for children up to 12 years.drop down grill frame on both sides for protection of the patient.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral white , bed side locker type i over all dimension :402mmlx422mm wx840mm ht .locker should have one cabinet and one drawer unit .both provided with cam lock .there should be gap between drawer and unit to keep general items for frequesnt use castors are provided for easy handling .drawer made up of crca sheet 1 mm thick and has ball slide for easy operation .top ss 304 sheet 0.8 mm thick castors 50 mmdia , hamdle abs ..powder coating of epoxy polyester , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , strecher on trolley type i 2005mm ( l ) x666mm ( w ) x827mm ( h ) .the trolley should be made of 31.75 and 25.4 mm dia 1.6 mm thick erw tube.holder for stretcher should be made up of mild steel.castor should be of 200 mm dia , diagonal locking castor.stretcher should be made up oferw tubeof dia 25.4 mm and thickness 1.6 mm.top sheet should be made of crca sheetof thickness 1.2 mm with contour shape to accommodate patient.iv pole holder should be made ofms .maximum safe work load should be 135 kg.to ensure qood quality welding co2 argonprocess should be adhered to.all metal componentsshould be pre treated with zinc phosphating in 9 tank porcess and then powder coated with anti microbialepoxy polyster powder coating.goods should be supplied in knocked down construction to reduce carbon emission. performance test :proof loading test , cycle tests , impact test, salt spray test, castor break test, the manufacturer should compilant with iso 9001, 14001, 13485, ohsas 1800 and ce certification. , doctor desk type x s / f / f executive table main desk should be of dimesion : 1350w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. side panels : ( black ) made form 18mm thick plt with pvc lipping.modesty panel : made form 18mm thick plt with pvc lipping. bigger upper panel in black and smaller lower panel in white cedar. made from 18mm thick plt with pvc lipping. mobile pedestal : one box and one filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , chair type iii s / f / f executive chair1 ) seat / back assembly: the seat and back are made up of 1.2 cm. thick hot pressed plywood, upholstered withfabric upholstery covers and moulded polyurethane foam. the back foam is designed with contoured lumbar support for extra comfort. the seat has extra thick foam on front edge to give comfort to popliteal area.high back size : 47.5 cm ( w ) x 69.5 cm ( h ) seat size : 47.0 cm. ( w ) x 48.0 cm. ( d ) 2 ) polyurethane foam: the polyurethane foam is moulded with density = 45 + / 2 kg / m 3and hardness = 20 + / 2at 25% compression. 3 ) armrests: the one piece armrests are injection moulded from black co polymer polypropylene. 4 ) center tilt synchro mechanism : the mechanism is designed with the following features:• 360 revolving type. • upright position locking. • tilt tension adjustment.• seat / back tilting ratio of 1:3 ( 60 seat tilt / 180 back tilt ) . 5 ) pneumatic height adjustment : the pneumatic height adjustment has anadjustment stroke of 12.0 cm. 6 ) telescopic bellow assembly : the bellow is 3 piece telescopic type and injection moulded in black polypropylene. 7 ) pedestal assembly , staff / visitor chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck .3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement.mx load bearing capacity should be 10 kg. , hospital curtain tracks & i.v. tree system supply installation testing & commissioning of cubical tracks system made of powder coated aluminium alloy, stain free polyster fabric , water repellent curtains , smooth movement , non sticking runnner with stainless steel hooks made from mirror finish stainless steel , adjustable height with all accessories. total quantity : 1...

Health And Family Welfare Department - Bihar

30458761 bids are invited for pile boring, providing and installation bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using direct mud circulation ( dmc ) or bailer and chisel technique by tripod and mechanical winch machine all complete, including removal of excavated earth with all its lifts and leads ( length of pile for payment shall be measured up to bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , upvc door providing and fixing of factory made upvc white colour casement door, upvc multichambered extruted frame, sash and mullion profile. frame duly reinforced with 1.2mm gi section box tpe chamber and sash with 1.5mm thick gi section ( ± 0.2mm ) based on wind load calculations ( shape and size according to upvc profiles ) , appropiate dimentions of upvc extruded glazing bead, epdm gasket ( k / o type ) , seperate drainage system, ss34 grade friction hinges 2d / 3d plate hinges, zinc alloy ( white powder coated ) casement handle, gi fastener 8x100 mm size for fixing frame to finish wall, plastic packer and caps and necessary steel screws etc.profile of frame and sash shall be metered cut and fusion welded at all corners, mullion shall be also fusion welded / joined mechanically including drilling of holes for fixing hardware and drainage of water etc. after fixing of frames , gap between frame and adjascent wall shall be filled with pu foaam / backer rod required size and the approved quantity. after that sealed with weather proof silicon sealant at both side, all complete as per approved drawing and direction of eic , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 1 providing and laying vitrified floor tiles in different sizes ( thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including grouting the joints with white cement and matching pigments etc., complete. size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge :flamed finish granite stone slab jet black, cherry red, elitebrown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item ( galvanised@80gsm ) 50 mm long 8mmouter diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’ , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975. the wind load shall be as per provisions of is 875 ( part iii ) . lgsfs frame shall be designed as per is: 801 using commercially available software such as frame cad pro 11.7 / staad pro v8i / architekv2.5.16 / revit architecture 2011 or equivalent. proper usage of connection accessories like heavy duty tension ties, light duty hold ons, twist straps ( to connect truss with wall frames ) , strong tie, tie rod, h brackets, boxing sections, l shaped angles for better structural stability. the framing section shall be cold form c type having minimum web depth 89 mm x 39mm flange x 11mm lip in required length as per structural design requirement duly punched with dimple / slot at required locations as per approved drawings. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm and. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , face panel providing and fixing in all exterior face panels breathable vapour barrier underneath the cementfiber board as per national building code 2009 complete as per direction of engineer in charge. , lap siding supplying and installation of moisture resistant / fire resistantlap siding 8 mm thick and width as per standard sizes made ofiber cement board with embossed decorative finish to give pleasing exterior fixed horizontally with staggered joints including minimum over lapof 32 mm external cement fibre boardconforming to is 14862:2000 offixed with self drilling / taping screws / fastners of approved make. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1 new work ( two or more coats ) over and including water tinnable priming coat with cement primer , ex. paint finishing walls with textured exterior paint of required shade : new work ( two or more coats applied @ 3.28 ltr / 10 sqm ) over and including priming coat of exterior primer applied @ 2.20kg / 10 sqm sqm , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel 1 steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , road providing and laying c.c. pavement of mix m 25 with ready mixed concrete from batching plant. the ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc.complete as per specifications and directions of engineer in charge. ( the panel shuttering work shall be paid for separately ) . ( note: cement content considered in this item is @ 330 kg / cum. excess / less cement used as per design mix is payable / recoverableseparately ) . , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 1 providing & fixing stone slab table rubbed, edges rounded and polished of size 75 x 50cm deep and 1.8 cm thick fixed in urinal patitions by cutting chase of appropriate width with chase cutter and embedding the stone in chase with epoxy grout or with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregste 6mm nominal size ) as per engineer in charge and finished smooth white agaria marble stone , phe 2 providing and fixing salem stainless steel a isi 304 ( 18 / 8 ) kitchen sink as per is: 13983 with ci brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required. kitchen sink with drain board510x1040mm bowl depth 200mm. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing:rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixturescomplete, including cutting and making good the walls andlevel whitep.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings andfloors wherever required :white vitreous china orissa pattern w.c. pan of size580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 9 providing and fixing cp brass 32mm size bottle trap of approved quality & make and as per the direction of engineer in charge.. ( sink & urinal ) , phe 10 providing & fixingptmt towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealedfittings arrangement of approved quality and colour weighing not less than 88 gms , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size 660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 15 providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water ( 250 ml & 500 ml consumption ) , having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of engineer in charge.. , phe 16 providing & fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. , phe 17 providing and fixing white vitreous china laboratory sink with c.i. brackets, c.p. brass chain with rubber plug, 40 mm c.p brass waste and 40mm c.p. brass trap with necessary c.p. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required :size 600x450x200 mm , phe 18 providing and fixing cp brass single lever telephonic wall mixer of quality & make as approved by engineer in charge . a ) 15 mm nominal dia. , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 21 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 24 two or more coats on new work over an under coat ofsuitable shade with ordinary paint of approved brand andmanufacturetwo more coast on new work , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm.clear depth and 250mm apron including cost of e / w. involved with 75mmcement concrete ( 1:4:8 ) over one brick designation 100 a flat soling inproper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 8 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia. exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 11 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 450 mm dia rcc pipe , ex. phe 12 inside size 120x90 cm and 90 cm deep including c.i. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg ) :with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , ex. phe 13 providing and fixing square mouth sw gully trap grade ‘a’ complete ci grating brick masonry chamber with bricks of class designation 75 and water tight ci cover with frame of 300 x 300 mm size ( inside ) the weight of cover to be not less than 13.00 kg and frame to be not less than 5 kg. as per standard design. ( cover min. 4.5 kg & frame min.2.7 kg ) 180x150 mm size p type with fps bricks , ex. phe 14 constructing masonry chamber 30x30x50 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement:4 coarce sand ) for stop cock complete with c.i. surface box 100x100x75mm ( inside ) with locking arrangement and rcc top slab 1:2:4 mix ( 1 cement : 2 corase sand: 4 graded stonr aggregate 20mm nominal size ) necessary excavation foundation concret 1:5:10 ( 1 cement:5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortor 1:3 ( 1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design. , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , ex. phe 16 structual steel work welded in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. , ex. phe 17 making connection of gi distribution branch with gi main of 50 80mm nominal bore by providing and fixing tee, including cutting and threading the pipe etc. complete. , rain water harvesting 1 boring / drilling bore well of required dia for casing / strainer pipe, bysuitable method prescribed in is:2800 ( part i ) , including collecting sample from different strata , preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90m depth below ground level.300 mm dia , rain water harvesting 2 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150mm nominal size dia , rain water harvesting 3 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well screen ( rms ) pipes with ribs, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150 mm nominal size dia , rain water harvesting 4 supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 5 supplying, filling, spreading & levelling gravel of size range 5mm to 10mm, in recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 7 providing and fixing bail plug / bottom plug of required dia to the bottom of pipe assembly of tube well as per is:2800 ( part i ) . 100 mm dia , rain water harvesting 8 making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and s.w. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , rain water harvesting 9 constructing soak pit 1.20x1.20x1.20 m filled with brickbats including s.w. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , tubewell 1 boring / drilling bore well of required dia for casing / strainer pipe, bysuitable method prescribed in is:2800 ( part i ) , including collecting sample from different strata , preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90m depth below ground level.300 mm dia , tubewell 2 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150mm nominal size dia , tubewell 3 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.100mm nominal size dia , tubewell 4 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well screen ( rms ) pipes with ribs, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.100 mm nominal size dia , tubewell 5 supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , tubewell 6 providing and fixing bail plug / bottom plug of required dia to the bottom of pipe assembly of tube well as per is:2800 ( part i ) . 100 mm dia , submersible pump 35m deep boring with casing and pipe. supply of pipe etc supplying & installation of suitable 2hp submersible pump b.s or k.s.bor equivalent make with finolex cable 1x3x2.5 squmm ( upto 50mtr ) withflexible conduit 25mm dia, electrical out door pannel with required electrical fitting such as mcb of 0 25amp ( havell or indocopp or mds make ) , volt & ampere meter ( ae make ) , single phase preventer ( minilac or vsp 1 make ) starter ( l&t or bch make ) etc of approved make, 40mm hdpe pipe ( 25 mtr ) and all accessories complete as per requirement of site. , water purifier and cooler 1 fitting and fixing single faucet storage type water cooler ( size 461 mm wide x 582 mm deep x 1217 mm height, weight 46 kg ) fully stainless body having storage capacity of 40 ltrs, cooling capacity of 40 ltrs. / hr. with hermetic type compressor, gas cooled motor equipped with over load protector, condensor for propeller type, thermostat autometically controlled temperature, refrigerent r 22, 230 volt, single phase 50 hertz, maximum current 2.3 amp including plug top and electrical lead wire connection upto 3 metres from the cooler, water inlet and drain out connections complete in all respects of voltas model no 40 / 40 tushar pss type or similar type of approved make. , water purifier and cooler 2 fitting and fixing water purifier for drinking purpose of capacity 6 litres / min, 5 purification system with reverse osmosis system with ultra ventilated membrane, tds500 to 2000 mgl / ppm, auto shut off with microswitch float manual flush facility, tds reduction 90% having automatic backwash system with filteration unit along with all accessories including plug top and electrical lead wire connection upto 3 metres from the purifier, water inlet and drain out connections complete in all respects similar to aquaguard or similar approved make ( model aquasure elegant ro water purifier of size width 360 mm x height 430 mm x depth 235 mm and weight 8.5 kg ) . , fire extinguisher 1 providing and fixing carbon di oxide type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. capacity 4.5 kg. , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 6.0 kg. , electrical 1 wiring for light point / fan point / exhaust fan point / call bellpoint with 1.5 sq.mm frls pvc insulated copper conductorsingle core cable in surface / recessed steel conduit, withmodular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. group c , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , pvc conduit 1 supplying and fixing of following sizes of medium class 20mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , pvc conduit 2 supplying and fixing of following sizes of medium class 32mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , pvc conduit 3 supplying and fixing of following sizes of medium class 50mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , electrical 4 wiring for light / power plug with 2x4 sq. mm frls pvcinsulated copper conductor single core cable in surface / recessed conduit alongwith 1 no. 4 sq. mm frls pvcinsulated copper conductor single core cable for loop earthingas required. , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 4 x 6 sq. mm + 2 x 6 sq. mm earth wire , wiring frls pvc insulated copper conductor 4 4 x 10 sq. mm + 2 x 6 sq. mm earth wire , wiring frls pvc insulated copper conductor 5 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 1 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 3 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 4 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 2 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 3 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 4 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 5 telephone socket outlet , s / f modular switch / socket on the existing modular plate 6 tv antenna socket outlet , s / f modular switch / socket on the existing modular plate 7 bell push , electrical 5 supplying & fixing suitable size gi box wih modular plate and cover in front on surface or in recess including providing and fixing 25 a modular socket outlet and 25 a modular sp mcb, “c” curve including connections, painting etc. as required. ( for ac / geyser ) , electrical 6 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface / recessed steel / pvc conduit as required. , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 11 supplying and fixing 20 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. , electrical 12 supplying and fixing 30 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , electrical 14 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 12 way , double door , electrical 15 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 16 way, double door , electrical 16 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 6 way ( 4 + 18 ) , double door , electrical 17 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way ( 4 + 24 ) , double door , electrical 18 supplying and fixing of following ways surface / recess mounting, vertical type, 415 v, tpn mcb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 a tinned copper bus bar, common neutral link, earth bar, din bar for mounting mcbs ( but without mcbs and incomer ) as required . ( note : vertical type mcb tpdb is normally usedwhere 3 phase outlets are required. ) 4 way ( 4 + 12 ) , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 63a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 100a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , l / f pvc sheathed / xlpe power cable in trench laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 95 sq. mm and upto 185 sq. mm , l / f pvc sheathed / xlpe power cable in trench 1 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 185 sq. mm and upto 400 sq. mm , l / f pvc sheathed / xlpe power cable over cable tray upto 35 sq. mm ( clamped with 1mm thick saddle ) , l / f pvc sheathed / xlpe power cable over cable tray 2 above 35 sq. mm and upto 95 sq. mm ( clamped with 25x3mm ms flat clamp ) , l / f pvc sheathed / xlpe power cable over cable tray 3 above 95 sq. mm and upto 185 sq. mm ( clamped with 25 / 40x3mm ms flat clamp ) , l / f pvc sheathed / xlpe power cable over cable tray 4 above 185 sq. mm and upto 400 sq. mm ( clamped with 40x3mm ms flat clamp ) , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 3.5c x 300 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 1 3.5c x 240 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 2 3.5c x 120 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 3 3.5c x 95 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 4 3.5c x 50 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 5 4c x 35 sqmm aluminium conductor cable a2xfy , cable tray supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 100 mm width x 50 mm depth x 1.6 mm thickness , cable tray 1 supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 300 mm width x 50 mm depth x 1.6 mm thickness , cable tray 2 supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 600 mm width x 62.5 mm depth x 2.0 mm thickness , cable tray “bends” supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.100 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 1 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.150 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 2 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.300 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 3 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.450 mm width x 50 mm depth x 2 mm thickness , cable tray “bends” 4 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.600 mm width x 62.5 mm depth x 2.0 mm thickness , mv cable supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 300 sqmm, aluminium conductor cable a2xfy , mv cable 1 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 240 sqmm, aluminium conductor cable a2xfy , mv cable 2 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 120 sqmm, aluminium conductor cable a2xfy , mv cable 3 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 95 sqmm, aluminium conductor cable a2xfy , earthing earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 1 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. , earthing 2 earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. , earthing 3 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 4 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , earthing 5 providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required. , earthing 6 providing and fixing earth bus of 50 mm x 5 mm copper strip on surface for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 4 supplying and fixing recess mounted 12 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 6 supply, installation, testing and commissioning of 400 mm sweep, 65w, blade material aluminium blades , speed & oscillation 3 speed, pull cord for speed and oscillation.air delivery minimum 72 m³ / min, speed minimun 1350 revolution per minute.suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , fiting & fixtures 8 supplying installation testing & commissioning ofb22 based 9w led 3 star bulb with 850 lumen, 6k color temperature including holder. , fiting & fixtures 9 supplying installation testing & commissioning of black painted extruded aluminium housing. green / red led’s mounted inside the housing. laser engraved signage matter on single / double acrylic sheet fixed on one side suitable for wall / ceiling / suspension type single / double sided display. in double sided version black paper is inserted. ni cd battery back up to 2 hrs. ( charged up to 8 10 hrs ) .mounting strings provided for pendent mounting operating voltage 150 280v ac ambient operating temperature. – 0 to 450c ingress protection – ip42.including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required.   220208 besl 03 led ssd wbb green 240 3 8wor220209 besl 03 led ssd wbb red 240 3 8wor220210 besl 03 led dsd wbb green 240 3 8wor220211 besl 03 led dsd wbb red 240 3 8w , fiting & fixtures 10 supply, installation, testing & erecting of ip66 bulkhead surface type lighting fixture 10w made up of pressure die cast aluminium housing and polyster powder coated die cast aluminium with high quality polycarbonate diffuser in opal finish for glare free light distribution.high efficiency long life led module with smd led package mounted on mcpcb with lumen efficacy of >95 lm / w with system lumen 950. powered by integral electronic led driver with apfc with low thd output short / open circuit protection. cct 5700, cri>80, system efficacy>90lm / w, thd<15%, pf>.95, ip66, ik 10, life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz.including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. cat ref: havells : hexaft10wled857ssymbopc or approved equivalent. , civil & misc works1 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. , civil & misc works2 providing and fixing h.t. danger notice plate of 250 mm x 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. , civil & misc works3 supplying and making cable route marker with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm x 60 cm at the bottom and 50 cm x 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. , civil & misc works4 supplying and fixing cable route marker with 10 cm x 10 cm x 5 mm thick g.i. plate with inscription there on, bolted / welded to 35 mm x 35 mm x 6 mm angle iron, 60 cm long and fixing the same in ground as required. , civil & misc works5 providing & fixing in position 1000 mm wide , electrical insulating rubber mats as per is 15652:2006, 2 mm thick, suitable up to 1.1 kv , fire retardant, no effect of acids, alkalis and transformer oils, moisture proof, high tensile strengthandtexture finish / cloth impression ( anti slip , marking on top ) , civil & misc works6 supply & fixing shock treatment chart duly mounted on a wooden frame with 5 mm thick glass as required ( approx front area 1.20 sq metre ) , 40 kvaups supplying, installation, testing and commissioningof online double conversion fully microprocessor based , indoor type, compact ups system of following rating with igbt based pwm technology to achieve thd < 3% and input power factor of greater than 0.95 at 50% loading, suitable for three phase ac input voltage 380 v to 440 v, 50 hz +3% / 3 % and three phase ac output voltage 415 ± 1% volts & frequency 50 ± 0.5 hz , inbuilt isolation transformer, necessary vrla batteries of suitable size having 30 minutes back up time , mounting rack including and suitable size connecting cable ( for ups to battery and battery to battery ) , static and maintenance bypass switch, snmp card for rs232 / ethernet ip computability for operation and monitoring etc. with all components as mentioned , specifications, complete as required.note : concerning vendor needs to furnish the battery sizing calculations at the time of ga approval and battery size has to be as per the approved ga drawing. , external lighting 1 supply and erection of 4 metre height hot dipgalvanized octagonal street light pole with followingarm with top dia 70 mm and bottom dia a / f 130 mm, made of 3 mm thick sheet along with base plate of size220 x 220 x 12 mm , small door opening for junctionbox mounting with mcb & connector, cement concreteof 1:3:6 including excavation, refilling and suitable sizefoundation bolts with template and all complete jobasrequired. ( but without pole collar ) single arm , external lighting 2 supplying and fixing 40 / 45 watt led type street lightwith die cast aluminium housing for ingress protectionof ip65 and complete with all accessories etc, onpole / building including connection with fr pvcinsulated copper conductor cable and earthing thebody etc. as required. , ip based cctv system 1 sitc of 2 megapixel @ 25fps, h.265 ip bullet camera, 1 / 2.9 cmos with 2.8~12mm varifocal lens, 0 lux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 2 sitc of 2 megapixel @ 25fps, h.265 ip dome camera, 1 / 2.9 cmos with 3.6 fixed mm 0 lux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 3 sitc of 2 megapixel @ 25fps, ptz camera h.265 ip dome camera, 1 / 2.9 cmos with 2.6 fixed lenslux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 4 sitc of 32ch 4k ivr , h.265 / h.264 • 1080p real time • 4k display • dual lan • 8x hdd • raid •web plugin free h.265 / h.264 compression technology 4k display for clear monitoring up to 1080p 16ch decoding ability smart search ii smart vca event searchsupport raid 0, 1, 5 supported to prevent from recording data loss browsers supported: ie , smart functions : target count, electric fence, face detection, humaniod detection, retrograde detection, leave position detectio output, local & network backup etc. complete as required. , cctv 5 sitc of harddiskdrive8tb, 24 / 7surveillance category only complete etc as required.etc.all complete , cctv 6 sitc of 55 led narrow bazel for monitoring for nvr server etc. all complete. , cctv 7 sitc of rj 45 outlets near the cameras etc. all complete. etc. all complete. , cctv 8 sitc of cat 6 patch cords 1 meter high quality four pair twisted stranded cable terminated with rj45 modular plugs at both the ends. , signage 1 providing & fixing of building direction signage mounted on pole, with pole of 100x100mm shs ( square hollow section ) of height of 5600mm, and sign size of 900x1050, sign made of aluminiu c section of 60mm with internal framing to support the frame in ms tubes hollow section, frame work duly painted with anti rust coatings, with facia of 3mm thick exterior grade aluminium composite panel, cladded with uv cured digital printed retroreflective sheet of 3m make, and back panel of 3mm exterior grade acp, all pipes to be painted in approved color. cost shall includecost towards installation, including excuvation and filling up with specified pcc and fixing of foundation bolts as specified, also it shall include the designing charges.all complete as per direction by engineer in charge. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , 2 tr air conditioning 1 split ac ( inverter model ) : supply, installation, testing, commissioning of split type wall mounted air conditioning units of following capacity including inddor, outdoor unit fitted with inverter based rotary compressor fitted with rotary compressor, copper condensor and first charge refrigent r410a / eco friendly green gas only, all complete including all electrical connections to the electrical power supply system of the building, includingbut not limited to supply of all electrical plugs, etc., as necessary, lengthening of all electrical wires of ac units ( both indoor and outdoor ) , drain pipe andincluding suitable voltage stabilisers, etc. so as to place them in a concealed manner in the desired position. the copper pipes and electrical cables shall be concealed in approved manner and neatly run in straight lines in a workman like manner with proper supports. complete supply and installation of split2 tr star rating 3 star , refrigerant piping copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 25 mm od, wall thickness >= 1.2 mm ( insulation 19 mm thick ) , refrigerant piping 1 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 19.1 mm od, wall thickness >= 1.0 mm ( insulation 13 mm thick ) , refrigerant piping 2 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 15.9 mm od, wall thickness >= 0.8 mm ( insulation 13 mm thick ) , refrigerant piping 3 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 9.5 mm od, wall thickness >= 0.8 mm ( insulation 13 mm thick ) , drain piping providing and fixing of cpvc 6 kg / cm2 drainpiping complete with fittings, supports, 6 mm thick closed cell elastomeric insulation as per specifications and drawings. 20 mm , drain piping 1 providing and fixing of cpvc 6 kg / cm2 drainpiping complete with fittings, supports, 6 mm thick closed cell elastomeric insulation as per specifications and drawings. 32 mm , main oxygen manifold supply, installation, testing and commissioning of following gas manifold system ( excluding cylinders ) . the manifold is configured for designed numbers of cylinders and is suitable to withstand a pressure of 145 kg / cm2, along withhigh pressure copper annealed tail pipes with end brass adapter suitable for cylinders and manifold. top frame comprising of high pressure copper pipes of size 1 / 2” nb x 15swg with high pressure brass fittings made of high tensile brass and connections through nonreturn valves, the design of middle and bottomframes is provided to fit both round and flat bottom cylinders safely. the manifold is tested ( hydraulically ) at 3500 psig. ( it should be ce and iso 13485 certified ) mani fold oxygen manifold 6 + 6 cylinder banks complete with nrv, middle frame, bottom frame with ce marked, , emergency manifold emergency oxygen manifold 01 + 01 cylinder emergency manifold with complete regulator, nrv, middle frame & bottom frame, , control panelfor oxygen fully automatic three port control panel for oxygen supply, installation, testing and commissioning of automatic manifold control panel would provide a duty or standby gas supply from two cylinder banks with automaticchangeover the manifold indicates local status and has a remote indicator facility. automaticmanifold control panel would be designed to supply the mgps with a constant pressure supply via a control panel form two equal banks of cylinders and the changeover from the ‘duty’ to the ‘standby’ bank of cylinders would beautomatic. automatic changeover from the duty to the standby bank would occur at a cylinder pressure that will ensure the maximum usage of the contents of the duty bank. the changeover unit would be provided with monitoring todetect and display: duty bank operating, duty bank empty, standby bank operating, and standby bank below 10 % when the duty bank is empty, reserve bank low, pipeline pressure fault. there would be facility to connect liquidoxygen supply ( i.e. three port control panel ) ( it should be ce and iso 13485 certified ) fully automatic three port control panel for oxygen , emergency manifold line regulator emergency manifold line regulator supply, installation, testing and commissioning of emergency manifold line regulator i n p u t p r e s s u r e 1 5 0 k g / c m 2 working pressure 4 kg / cm2 it should be ce and iso 13485 certified.oxygen input pressure 150 kg / cm2 working pressure 4 kg / cm2capacity : 1500 lpm , cylinderconnectingpipe ( pig tail ) supply, installation, testing and commissioning of cylinder connecting pipe ( pig tail ) made up of flexible ss hose with safety cord 5 / 8 inch bsp gland nut and one side 1 / 2 inch bsp internal threads having one meter length. ( oxygen 24 , n2o 10, co2 4 ) , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , medical air ( 4 bar ) outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve, supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified.42mm , isolation valve 2 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 28mm , isolation valve 3 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 22mm , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness , pipeline 4 medical grade copper pipeline ( in mtrs. ) as per en 13348, 28 mm ( od ) x 0.9 mm thickness , pipeline 5 medical grade copper pipeline ( in mtrs. ) as per en 13348, 42 mm ( od ) x 1.2 mm thickness , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 2268 mm x ( w ) 922 mm x ( h ) 610 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , paediatric bed with mattress paediatric bed of overall sizes in mm: 1500 ( l ) x 850 ( w ) x 1210 ( h ) flat single section bed with grille frame on 4 sides.suitable for children up to 12 years.drop down grill frame on both sides for protection of the patient.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral white , bed side locker type i over all dimension :402mmlx422mm wx840mm ht .locker should have one cabinet and one drawer unit .both provided with cam lock .there should be gap between drawer and unit to keep general items for frequesnt use castors are provided for easy handling .drawer made up of crca sheet 1 mm thick and has ball slide for easy operation .top ss 304 sheet 0.8 mm thick castors 50 mmdia , hamdle abs ..powder coating of epoxy polyester , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , strecher on trolley type i 2005mm ( l ) x666mm ( w ) x827mm ( h ) .the trolley should be made of 31.75 and 25.4 mm dia 1.6 mm thick erw tube.holder for stretcher should be made up of mild steel.castor should be of 200 mm dia , diagonal locking castor.stretcher should be made up oferw tubeof dia 25.4 mm and thickness 1.6 mm.top sheet should be made of crca sheetof thickness 1.2 mm with contour shape to accommodate patient.iv pole holder should be made ofms .maximum safe work load should be 135 kg.to ensure qood quality welding co2 argonprocess should be adhered to.all metal componentsshould be pre treated with zinc phosphating in 9 tank porcess and then powder coated with anti microbialepoxy polyster powder coating.goods should be supplied in knocked down construction to reduce carbon emission. performance test :proof loading test , cycle tests , impact test, salt spray test, castor break test, the manufacturer should compilant with iso 9001, 14001, 13485, ohsas 1800 and ce certification. , doctor desk type x s / f / f executive table main desk should be of dimesion : 1350w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. side panels : ( black ) made form 18mm thick plt with pvc lipping.modesty panel : made form 18mm thick plt with pvc lipping. bigger upper panel in black and smaller lower panel in white cedar. made from 18mm thick plt with pvc lipping. mobile pedestal : one box and one filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , chair type iii s / f / f executive chair1 ) seat / back assembly: the seat and back are made up of 1.2 cm. thick hot pressed plywood, upholstered withfabric upholstery covers and moulded polyurethane foam. the back foam is designed with contoured lumbar support for extra comfort. the seat has extra thick foam on front edge to give comfort to popliteal area.high back size : 47.5 cm ( w ) x 69.5 cm ( h ) seat size : 47.0 cm. ( w ) x 48.0 cm. ( d ) 2 ) polyurethane foam: the polyurethane foam is moulded with density = 45 + / 2 kg / m 3and hardness = 20 + / 2at 25% compression. 3 ) armrests: the one piece armrests are injection moulded from black co polymer polypropylene. 4 ) center tilt synchro mechanism : the mechanism is designed with the following features:• 360 revolving type. • upright position locking. • tilt tension adjustment.• seat / back tilting ratio of 1:3 ( 60 seat tilt / 180 back tilt ) . 5 ) pneumatic height adjustment : the pneumatic height adjustment has anadjustment stroke of 12.0 cm. 6 ) telescopic bellow assembly : the bellow is 3 piece telescopic type and injection moulded in black polypropylene. 7 ) pedestal assembly : . , staff / visitor chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck .3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement.mx load bearing capacity should be 10 kg. , hospital curtain tracks & i.v. tree system supply installation testing & commissioning of cubical tracks system made of powder coated aluminium alloy, stain free polyster fabric , water repellent curtains , smooth movement , non sticking runnner with stainless steel hooks made from mirror finish stainless steel , adjustable height with all accessories. total quantity : 1...

Health And Family Welfare Department - Bihar

30457596 bids are invited for pile boring, providing and installation bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using direct mud circulation ( dmc ) or bailer and chisel technique by tripod and mechanical winch machine all complete, including removal of excavated earth with all its lifts and leads ( length of pile for payment shall be measured up to bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , upvc door providing and fixing of factory made upvc white colour casement door, upvc multichambered extruted frame, sash and mullion profile. frame duly reinforced with 1.2mm gi section box tpe chamber and sash with 1.5mm thick gi section ( ± 0.2mm ) based on wind load calculations ( shape and size according to upvc profiles ) , appropiate dimentions of upvc extruded glazing bead, epdm gasket ( k / o type ) , seperate drainage system, ss34 grade friction hinges 2d / 3d plate hinges, zinc alloy ( white powder coated ) casement handle, gi fastener 8x100 mm size for fixing frame to finish wall, plastic packer and caps and necessary steel screws etc.profile of frame and sash shall be metered cut and fusion welded at all corners, mullion shall be also fusion welded / joined mechanically including drilling of holes for fixing hardware and drainage of water etc. after fixing of frames , gap between frame and adjascent wall shall be filled with pu foaam / backer rod required size and the approved quantity. after that sealed with weather proof silicon sealant at both side, all complete as per approved drawing and direction of eic , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 1 providing and laying vitrified floor tiles in different sizes ( thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including grouting the joints with white cement and matching pigments etc., complete. size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge :flamed finish granite stone slab jet black, cherry red, elitebrown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item ( galvanised@80gsm ) 50 mm long 8mmouter diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’ , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975. the wind load shall be as per provisions of is 875 ( part iii ) . lgsfs frame shall be designed as per is: 801 using commercially available software such as frame cad pro 11.7 / staad pro v8i / architekv2.5.16 / revit architecture 2011 or equivalent. proper usage of connection accessories like heavy duty tension ties, light duty hold ons, twist straps ( to connect truss with wall frames ) , strong tie, tie rod, h brackets, boxing sections, l shaped angles for better structural stability. the framing section shall be cold form c type having minimum web depth 89 mm x 39mm flange x 11mm lip in required length as per structural design requirement duly punched with dimple / slot at required locations as per approved drawings. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm and. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , face panel providing and fixing in all exterior face panels breathable vapour barrier underneath the cementfiber board as per national building code 2009 complete as per direction of engineer in charge. , lap siding supplying and installation of moisture resistant / fire resistantlap siding 8 mm thick and width as per standard sizes made ofiber cement board with embossed decorative finish to give pleasing exterior fixed horizontally with staggered joints including minimum over lapof 32 mm external cement fibre boardconforming to is 14862:2000 offixed with self drilling / taping screws / fastners of approved make. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1 new work ( two or more coats ) over and including water tinnable priming coat with cement primer , ex. paint finishing walls with textured exterior paint of required shade : new work ( two or more coats applied @ 3.28 ltr / 10 sqm ) over and including priming coat of exterior primer applied @ 2.20kg / 10 sqm sqm , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel 1 steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , road providing and laying c.c. pavement of mix m 25 with ready mixed concrete from batching plant. the ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc.complete as per specifications and directions of engineer in charge. ( the panel shuttering work shall be paid for separately ) . ( note: cement content considered in this item is @ 330 kg / cum. excess / less cement used as per design mix is payable / recoverableseparately ) . , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 1 providing & fixing stone slab table rubbed, edges rounded and polished of size 75 x 50cm deep and 1.8 cm thick fixed in urinal patitions by cutting chase of appropriate width with chase cutter and embedding the stone in chase with epoxy grout or with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregste 6mm nominal size ) as per engineer in charge and finished smooth white agaria marble stone , phe 2 providing and fixing salem stainless steel a isi 304 ( 18 / 8 ) kitchen sink as per is: 13983 with ci brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required. kitchen sink with drain board510x1040mm bowl depth 200mm. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing:rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixturescomplete, including cutting and making good the walls andlevel whitep.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings andfloors wherever required :white vitreous china orissa pattern w.c. pan of size580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 9 providing and fixing cp brass 32mm size bottle trap of approved quality & make and as per the direction of engineer in charge.. ( sink & urinal ) , phe 10 providing & fixingptmt towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealedfittings arrangement of approved quality and colour weighing not less than 88 gms , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size 660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 15 providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water ( 250 ml & 500 ml consumption ) , having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of engineer in charge.. , phe 16 providing & fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. , phe 17 providing and fixing white vitreous china laboratory sink with c.i. brackets, c.p. brass chain with rubber plug, 40 mm c.p brass waste and 40mm c.p. brass trap with necessary c.p. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required :size 600x450x200 mm , phe 18 providing and fixing cp brass single lever telephonic wall mixer of quality & make as approved by engineer in charge . a ) 15 mm nominal dia. , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 21 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 24 two or more coats on new work over an under coat ofsuitable shade with ordinary paint of approved brand andmanufacturetwo more coast on new work , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm.clear depth and 250mm apron including cost of e / w. involved with 75mmcement concrete ( 1:4:8 ) over one brick designation 100 a flat soling inproper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 8 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia. exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 11 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 450 mm dia rcc pipe , ex. phe 12 inside size 120x90 cm and 90 cm deep including c.i. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg ) :with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , ex. phe 13 providing and fixing square mouth sw gully trap grade ‘a’ complete ci grating brick masonry chamber with bricks of class designation 75 and water tight ci cover with frame of 300 x 300 mm size ( inside ) the weight of cover to be not less than 13.00 kg and frame to be not less than 5 kg. as per standard design. ( cover min. 4.5 kg & frame min.2.7 kg ) 180x150 mm size p type with fps bricks , ex. phe 14 constructing masonry chamber 30x30x50 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement:4 coarce sand ) for stop cock complete with c.i. surface box 100x100x75mm ( inside ) with locking arrangement and rcc top slab 1:2:4 mix ( 1 cement : 2 corase sand: 4 graded stonr aggregate 20mm nominal size ) necessary excavation foundation concret 1:5:10 ( 1 cement:5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortor 1:3 ( 1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design. , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , ex. phe 16 structual steel work welded in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. , ex. phe 17 making connection of gi distribution branch with gi main of 50 80mm nominal bore by providing and fixing tee, including cutting and threading the pipe etc. complete. , rain water harvesting 1 boring / drilling bore well of required dia for casing / strainer pipe, bysuitable method prescribed in is:2800 ( part i ) , including collecting sample from different strata , preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90m depth below ground level.300 mm dia , rain water harvesting 2 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150mm nominal size dia , rain water harvesting 3 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well screen ( rms ) pipes with ribs, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150 mm nominal size dia , rain water harvesting 4 supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 5 supplying, filling, spreading & levelling gravel of size range 5mm to 10mm, in recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 7 providing and fixing bail plug / bottom plug of required dia to the bottom of pipe assembly of tube well as per is:2800 ( part i ) . 100 mm dia , rain water harvesting 8 making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and s.w. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , rain water harvesting 9 constructing soak pit 1.20x1.20x1.20 m filled with brickbats including s.w. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , tubewell 1 boring / drilling bore well of required dia for casing / strainer pipe, bysuitable method prescribed in is:2800 ( part i ) , including collecting sample from different strata , preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90m depth below ground level.300 mm dia , tubewell 2 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150mm nominal size dia , tubewell 3 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.100mm nominal size dia , tubewell 4 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well screen ( rms ) pipes with ribs, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.100 mm nominal size dia , tubewell 5 supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , tubewell 6 providing and fixing bail plug / bottom plug of required dia to the bottom of pipe assembly of tube well as per is:2800 ( part i ) . 100 mm dia , submersible pump 35m deep boring with casing and pipe. supply of pipe etc supplying & installation of suitable 2hp submersible pump b.s or k.s.bor equivalent make with finolex cable 1x3x2.5 squmm ( upto 50mtr ) withflexible conduit 25mm dia, electrical out door pannel with required electrical fitting such as mcb of 0 25amp ( havell or indocopp or mds make ) , volt & ampere meter ( ae make ) , single phase preventer ( minilac or vsp 1 make ) starter ( l&t or bch make ) etc of approved make, 40mm hdpe pipe ( 25 mtr ) and all accessories complete as per requirement of site. , water purifier and cooler 1 fitting and fixing single faucet storage type water cooler ( size 461 mm wide x 582 mm deep x 1217 mm height, weight 46 kg ) fully stainless body having storage capacity of 40 ltrs, cooling capacity of 40 ltrs. / hr. with hermetic type compressor, gas cooled motor equipped with over load protector, condensor for propeller type, thermostat autometically controlled temperature, refrigerent r 22, 230 volt, single phase 50 hertz, maximum current 2.3 amp including plug top and electrical lead wire connection upto 3 metres from the cooler, water inlet and drain out connections complete in all respects of voltas model no 40 / 40 tushar pss type or similar type of approved make. , water purifier and cooler 2 fitting and fixing water purifier for drinking purpose of capacity 6 litres / min, 5 purification system with reverse osmosis system with ultra ventilated membrane, tds500 to 2000 mgl / ppm, auto shut off with microswitch float manual flush facility, tds reduction 90% having automatic backwash system with filteration unit along with all accessories including plug top and electrical lead wire connection upto 3 metres from the purifier, water inlet and drain out connections complete in all respects similar to aquaguard or similar approved make ( model aquasure elegant ro water purifier of size width 360 mm x height 430 mm x depth 235 mm and weight 8.5 kg ) . , fire extinguisher 1 providing and fixing carbon di oxide type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. capacity 4.5 kg. , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 6.0 kg. , electrical 1 wiring for light point / fan point / exhaust fan point / call bellpoint with 1.5 sq.mm frls pvc insulated copper conductorsingle core cable in surface / recessed steel conduit, withmodular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. group c , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , pvc conduit 1 supplying and fixing of following sizes of medium class 20mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , pvc conduit 2 supplying and fixing of following sizes of medium class 32mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , pvc conduit 3 supplying and fixing of following sizes of medium class 50mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , electrical 4 wiring for light / power plug with 2x4 sq. mm frls pvcinsulated copper conductor single core cable in surface / recessed conduit alongwith 1 no. 4 sq. mm frls pvcinsulated copper conductor single core cable for loop earthingas required. , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 4 x 6 sq. mm + 2 x 6 sq. mm earth wire , wiring frls pvc insulated copper conductor 4 4 x 10 sq. mm + 2 x 6 sq. mm earth wire , wiring frls pvc insulated copper conductor 5 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 1 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 3 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 4 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 2 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 3 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 4 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 5 telephone socket outlet , s / f modular switch / socket on the existing modular plate 6 tv antenna socket outlet , s / f modular switch / socket on the existing modular plate 7 bell push , electrical 5 supplying & fixing suitable size gi box wih modular plate and cover in front on surface or in recess including providing and fixing 25 a modular socket outlet and 25 a modular sp mcb, “c” curve including connections, painting etc. as required. ( for ac / geyser ) , electrical 6 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface / recessed steel / pvc conduit as required. , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 11 supplying and fixing 20 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. , electrical 12 supplying and fixing 30 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , electrical 14 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 12 way , double door , electrical 15 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 16 way, double door , electrical 16 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 6 way ( 4 + 18 ) , double door , electrical 17 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way ( 4 + 24 ) , double door , electrical 18 supplying and fixing of following ways surface / recess mounting, vertical type, 415 v, tpn mcb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 a tinned copper bus bar, common neutral link, earth bar, din bar for mounting mcbs ( but without mcbs and incomer ) as required . ( note : vertical type mcb tpdb is normally usedwhere 3 phase outlets are required. ) 4 way ( 4 + 12 ) , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 63a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 100a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , l / f pvc sheathed / xlpe power cable in trench laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 95 sq. mm and upto 185 sq. mm , l / f pvc sheathed / xlpe power cable in trench 1 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 185 sq. mm and upto 400 sq. mm , l / f pvc sheathed / xlpe power cable over cable tray upto 35 sq. mm ( clamped with 1mm thick saddle ) , l / f pvc sheathed / xlpe power cable over cable tray 2 above 35 sq. mm and upto 95 sq. mm ( clamped with 25x3mm ms flat clamp ) , l / f pvc sheathed / xlpe power cable over cable tray 3 above 95 sq. mm and upto 185 sq. mm ( clamped with 25 / 40x3mm ms flat clamp ) , l / f pvc sheathed / xlpe power cable over cable tray 4 above 185 sq. mm and upto 400 sq. mm ( clamped with 40x3mm ms flat clamp ) , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 3.5c x 300 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 1 3.5c x 240 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 2 3.5c x 120 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 3 3.5c x 95 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 4 3.5c x 50 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 5 4c x 35 sqmm aluminium conductor cable a2xfy , cable tray supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 100 mm width x 50 mm depth x 1.6 mm thickness , cable tray 1 supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 300 mm width x 50 mm depth x 1.6 mm thickness , cable tray 2 supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 600 mm width x 62.5 mm depth x 2.0 mm thickness , cable tray “bends” supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.100 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 1 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.150 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 2 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.300 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 3 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.450 mm width x 50 mm depth x 2 mm thickness , cable tray “bends” 4 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.600 mm width x 62.5 mm depth x 2.0 mm thickness , mv cable supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 300 sqmm, aluminium conductor cable a2xfy , mv cable 1 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 240 sqmm, aluminium conductor cable a2xfy , mv cable 2 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 120 sqmm, aluminium conductor cable a2xfy , mv cable 3 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 95 sqmm, aluminium conductor cable a2xfy , earthing earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 1 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. , earthing 2 earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. , earthing 3 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 4 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , earthing 5 providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required. , earthing 6 providing and fixing earth bus of 50 mm x 5 mm copper strip on surface for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 4 supplying and fixing recess mounted 12 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 6 supply, installation, testing and commissioning of 400 mm sweep, 65w, blade material aluminium blades , speed & oscillation 3 speed, pull cord for speed and oscillation.air delivery minimum 72 m³ / min, speed minimun 1350 revolution per minute.suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , fiting & fixtures 8 supplying installation testing & commissioning ofb22 based 9w led 3 star bulb with 850 lumen, 6k color temperature including holder. , fiting & fixtures 9 supplying installation testing & commissioning of black painted extruded aluminium housing. green / red led’s mounted inside the housing. laser engraved signage matter on single / double acrylic sheet fixed on one side suitable for wall / ceiling / suspension type single / double sided display. in double sided version black paper is inserted. ni cd battery back up to 2 hrs. ( charged up to 8 10 hrs ) .mounting strings provided for pendent mounting operating voltage 150 280v ac ambient operating temperature. – 0 to 450c ingress protection – ip42.including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required.   220208 besl 03 led ssd wbb green 240 3 8wor220209 besl 03 led ssd wbb red 240 3 8wor220210 besl 03 led dsd wbb green 240 3 8wor220211 besl 03 led dsd wbb red 240 3 8w , fiting & fixtures 10 supply, installation, testing & erecting of ip66 bulkhead surface type lighting fixture 10w made up of pressure die cast aluminium housing and polyster powder coated die cast aluminium with high quality polycarbonate diffuser in opal finish for glare free light distribution.high efficiency long life led module with smd led package mounted on mcpcb with lumen efficacy of >95 lm / w with system lumen 950. powered by integral electronic led driver with apfc with low thd output short / open circuit protection. cct 5700, cri>80, system efficacy>90lm / w, thd<15%, pf>.95, ip66, ik 10, life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz.including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. cat ref: havells : hexaft10wled857ssymbopc or approved equivalent. , civil & misc works1 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. , civil & misc works2 providing and fixing h.t. danger notice plate of 250 mm x 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. , civil & misc works3 supplying and making cable route marker with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm x 60 cm at the bottom and 50 cm x 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. , civil & misc works4 supplying and fixing cable route marker with 10 cm x 10 cm x 5 mm thick g.i. plate with inscription there on, bolted / welded to 35 mm x 35 mm x 6 mm angle iron, 60 cm long and fixing the same in ground as required. , civil & misc works5 providing & fixing in position 1000 mm wide , electrical insulating rubber mats as per is 15652:2006, 2 mm thick, suitable up to 1.1 kv , fire retardant, no effect of acids, alkalis and transformer oils, moisture proof, high tensile strengthandtexture finish / cloth impression ( anti slip , marking on top ) , civil & misc works6 supply & fixing shock treatment chart duly mounted on a wooden frame with 5 mm thick glass as required ( approx front area 1.20 sq metre ) , 40 kvaups supplying, installation, testing and commissioningof online double conversion fully microprocessor based , indoor type, compact ups system of following rating with igbt based pwm technology to achieve thd < 3% and input power factor of greater than 0.95 at 50% loading, suitable for three phase ac input voltage 380 v to 440 v, 50 hz +3% / 3 % and three phase ac output voltage 415 ± 1% volts & frequency 50 ± 0.5 hz , inbuilt isolation transformer, necessary vrla batteries of suitable size having 30 minutes back up time , mounting rack including and suitable size connecting cable ( for ups to battery and battery to battery ) , static and maintenance bypass switch, snmp card for rs232 / ethernet ip computability for operation and monitoring etc. with all components as mentioned , specifications, complete as required.note : concerning vendor needs to furnish the battery sizing calculations at the time of ga approval and battery size has to be as per the approved ga drawing. , external lighting 1 supply and erection of 4 metre height hot dipgalvanized octagonal street light pole with followingarm with top dia 70 mm and bottom dia a / f 130 mm, made of 3 mm thick sheet along with base plate of size220 x 220 x 12 mm , small door opening for junctionbox mounting with mcb & connector, cement concreteof 1:3:6 including excavation, refilling and suitable sizefoundation bolts with template and all complete jobasrequired. ( but without pole collar ) single arm , external lighting 2 supplying and fixing 40 / 45 watt led type street lightwith die cast aluminium housing for ingress protectionof ip65 and complete with all accessories etc, onpole / building including connection with fr pvcinsulated copper conductor cable and earthing thebody etc. as required. , ip based cctv system 1 sitc of 2 megapixel @ 25fps, h.265 ip bullet camera, 1 / 2.9 cmos with 2.8~12mm varifocal lens, 0 lux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 2 sitc of 2 megapixel @ 25fps, h.265 ip dome camera, 1 / 2.9 cmos with 3.6 fixed mm 0 lux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 3 sitc of 2 megapixel @ 25fps, ptz camera h.265 ip dome camera, 1 / 2.9 cmos with 2.6 fixed lenslux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 4 sitc of 32ch 4k ivr , h.265 / h.264 • 1080p real time • 4k display • dual lan • 8x hdd • raid •web plugin free h.265 / h.264 compression technology 4k display for clear monitoring up to 1080p 16ch decoding ability smart search ii smart vca event searchsupport raid 0, 1, 5 supported to prevent from recording data loss browsers supported: ie , smart functions : target count, electric fence, face detection, humaniod detection, retrograde detection, leave position detectio output, local & network backup etc. complete as required. , cctv 5 sitc of harddiskdrive8tb, 24 / 7surveillance category only complete etc as required.etc.all complete , cctv 6 sitc of 55 led narrow bazel for monitoring for nvr server etc. all complete. , cctv 7 sitc of rj 45 outlets near the cameras etc. all complete. etc. all complete. , cctv 8 sitc of cat 6 patch cords 1 meter high quality four pair twisted stranded cable terminated with rj45 modular plugs at both the ends. , signage 1 providing & fixing of building direction signage mounted on pole, with pole of 100x100mm shs ( square hollow section ) of height of 5600mm, and sign size of 900x1050, sign made of aluminiu c section of 60mm with internal framing to support the frame in ms tubes hollow section, frame work duly painted with anti rust coatings, with facia of 3mm thick exterior grade aluminium composite panel, cladded with uv cured digital printed retroreflective sheet of 3m make, and back panel of 3mm exterior grade acp, all pipes to be painted in approved color. cost shall includecost towards installation, including excuvation and filling up with specified pcc and fixing of foundation bolts as specified, also it shall include the designing charges.all complete as per direction by engineer in charge. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , 2 tr air conditioning 1 split ac ( inverter model ) : supply, installation, testing, commissioning of split type wall mounted air conditioning units of following capacity including inddor, outdoor unit fitted with inverter based rotary compressor fitted with rotary compressor, copper condensor and first charge refrigent r410a / eco friendly green gas only, all complete including all electrical connections to the electrical power supply system of the building, includingbut not limited to supply of all electrical plugs, etc., as necessary, lengthening of all electrical wires of ac units ( both indoor and outdoor ) , drain pipe andincluding suitable voltage stabilisers, etc. so as to place them in a concealed manner in the desired position. the copper pipes and electrical cables shall be concealed in approved manner and neatly run in straight lines in a workman like manner with proper supports. complete supply and installation of split2 tr star rating 3 star , refrigerant piping copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 25 mm od, wall thickness >= 1.2 mm ( insulation 19 mm thick ) , refrigerant piping 1 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 19.1 mm od, wall thickness >= 1.0 mm ( insulation 13 mm thick ) , refrigerant piping 2 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 15.9 mm od, wall thickness >= 0.8 mm ( insulation 13 mm thick ) , refrigerant piping 3 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 9.5 mm od, wall thickness >= 0.8 mm ( insulation 13 mm thick ) , drain piping providing and fixing of cpvc 6 kg / cm2 drainpiping complete with fittings, supports, 6 mm thick closed cell elastomeric insulation as per specifications and drawings. 20 mm , drain piping 1 providing and fixing of cpvc 6 kg / cm2 drainpiping complete with fittings, supports, 6 mm thick closed cell elastomeric insulation as per specifications and drawings. 32 mm , main oxygen manifold supply, installation, testing and commissioning of following gas manifold system ( excluding cylinders ) . the manifold is configured for designed numbers of cylinders and is suitable to withstand a pressure of 145 kg / cm2, along withhigh pressure copper annealed tail pipes with end brass adapter suitable for cylinders and manifold. top frame comprising of high pressure copper pipes of size 1 / 2” nb x 15swg with high pressure brass fittings made of high tensile brass and connections through nonreturn valves, the design of middle and bottomframes is provided to fit both round and flat bottom cylinders safely. the manifold is tested ( hydraulically ) at 3500 psig. ( it should be ce and iso 13485 certified ) mani fold oxygen manifold 6 + 6 cylinder banks complete with nrv, middle frame, bottom frame with ce marked, , emergency manifold emergency oxygen manifold 01 + 01 cylinder emergency manifold with complete regulator, nrv, middle frame & bottom frame, , control panelfor oxygen fully automatic three port control panel for oxygen supply, installation, testing and commissioning of automatic manifold control panel would provide a duty or standby gas supply from two cylinder banks with automaticchangeover the manifold indicates local status and has a remote indicator facility. automaticmanifold control panel would be designed to supply the mgps with a constant pressure supply via a control panel form two equal banks of cylinders and the changeover from the ‘duty’ to the ‘standby’ bank of cylinders would beautomatic. automatic changeover from the duty to the standby bank would occur at a cylinder pressure that will ensure the maximum usage of the contents of the duty bank. the changeover unit would be provided with monitoring todetect and display: duty bank operating, duty bank empty, standby bank operating, and standby bank below 10 % when the duty bank is empty, reserve bank low, pipeline pressure fault. there would be facility to connect liquidoxygen supply ( i.e. three port control panel ) ( it should be ce and iso 13485 certified ) fully automatic three port control panel for oxygen , emergency manifold line regulator emergency manifold line regulator supply, installation, testing and commissioning of emergency manifold line regulator i n p u t p r e s s u r e 1 5 0 k g / c m 2 working pressure 4 kg / cm2 it should be ce and iso 13485 certified.oxygen input pressure 150 kg / cm2 working pressure 4 kg / cm2capacity : 1500 lpm , cylinderconnectingpipe ( pig tail ) supply, installation, testing and commissioning of cylinder connecting pipe ( pig tail ) made up of flexible ss hose with safety cord 5 / 8 inch bsp gland nut and one side 1 / 2 inch bsp internal threads having one meter length. ( oxygen 24 , n2o 10, co2 4 ) , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , medical air ( 4 bar ) outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve, supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified.42mm , isolation valve 2 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 28mm , isolation valve 3 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 22mm , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness , pipeline 4 medical grade copper pipeline ( in mtrs. ) as per en 13348, 28 mm ( od ) x 0.9 mm thickness , pipeline 5 medical grade copper pipeline ( in mtrs. ) as per en 13348, 42 mm ( od ) x 1.2 mm thickness , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 2268 mm x ( w ) 922 mm x ( h ) 610 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , paediatric bed with mattress paediatric bed of overall sizes in mm: 1500 ( l ) x 850 ( w ) x 1210 ( h ) flat single section bed with grille frame on 4 sides.suitable for children up to 12 years.drop down grill frame on both sides for protection of the patient.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral white , bed side locker type i over all dimension :402mmlx422mm wx840mm ht .locker should have one cabinet and one drawer unit .both provided with cam lock .there should be gap between drawer and unit to keep general items for frequesnt use castors are provided for easy handling .drawer made up of crca sheet 1 mm thick and has ball slide for easy operation .top ss 304 sheet 0.8 mm thick castors 50 mmdia , hamdle abs ..powder coating of epoxy polyester , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , strecher on trolley type i 2005mm ( l ) x666mm ( w ) x827mm ( h ) .the trolley should be made of 31.75 and 25.4 mm dia 1.6 mm thick erw tube.holder for stretcher should be made up of mild steel.castor should be of 200 mm dia , diagonal locking castor.stretcher should be made up oferw tubeof dia 25.4 mm and thickness 1.6 mm.top sheet should be made of crca sheetof thickness 1.2 mm with contour shape to accommodate patient.iv pole holder should be made ofms .maximum safe work load should be 135 kg.to ensure qood quality welding co2 argonprocess should be adhered to.all metal componentsshould be pre treated with zinc phosphating in 9 tank porcess and then powder coated with anti microbialepoxy polyster powder coating.goods should be supplied in knocked down construction to reduce carbon emission. performance test :proof loading test , cycle tests , impact test, salt spray test, castor break test, the manufacturer should compilant with iso 9001, 14001, 13485, ohsas 1800 and ce certification. , doctor desk type x s / f / f executive table main desk should be of dimesion : 1350w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. side panels : ( black ) made form 18mm thick plt with pvc lipping.modesty panel : made form 18mm thick plt with pvc lipping. bigger upper panel in black and smaller lower panel in white cedar. made from 18mm thick plt with pvc lipping. mobile pedestal : one box and one filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , chair type iii s / f / f executive chair1 ) seat / back assembly: the seat and back are made up of 1.2 cm. thick hot pressed plywood, upholstered withfabric upholstery covers and moulded polyurethane foam. the back foam is designed with contoured lumbar support for extra comfort. the seat has extra thick foam on front edge to give comfort to popliteal area.high back size : 47.5 cm ( w ) x 69.5 cm ( h ) seat size : 47.0 cm. ( w ) x 48.0 cm. ( d ) 2 ) polyurethane foam: the polyurethane foam is moulded with density = 45 + / 2 kg / m 3and hardness = 20 + / 2at 25% compression. 3 ) armrests: the one piece armrests are injection moulded from black co polymer polypropylene. 4 ) center tilt synchro mechanism : the mechanism is designed with the following features:• 360 revolving type. • upright position locking. • tilt tension adjustment.• seat / back tilting ratio of 1:3 ( 60 seat tilt / 180 back tilt ) . 5 ) pneumatic height adjustment : the pneumatic height adjustment has anadjustment stroke of 12.0 cm. 6 ) telescopic bellow assembly : the bellow is 3 piece telescopic type and injection moulded in black polypropylene. 7 ) pedestal assembly : . , staff / visitor chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck .3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement.mx load bearing capacity should be 10 kg. , hospital curtain tracks & i.v. tree system supply installation testing & commissioning of cubical tracks system made of powder coated aluminium alloy, stain free polyster fabric , water repellent curtains , smooth movement , non sticking runnner with stainless steel hooks made from mirror finish stainless steel , adjustable height with all accessories. total quantity : 1...

Health And Family Welfare Department - Bihar

30457511 bids are invited for pile boring, providing and installation bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using direct mud circulation ( dmc ) or bailer and chisel technique by tripod and mechanical winch machine all complete, including removal of excavated earth with all its lifts and leads ( length of pile for payment shall be measured up to bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , upvc door providing and fixing of factory made upvc white colour casement door, upvc multichambered extruted frame, sash and mullion profile. frame duly reinforced with 1.2mm gi section box tpe chamber and sash with 1.5mm thick gi section ( ± 0.2mm ) based on wind load calculations ( shape and size according to upvc profiles ) , appropiate dimentions of upvc extruded glazing bead, epdm gasket ( k / o type ) , seperate drainage system, ss34 grade friction hinges 2d / 3d plate hinges, zinc alloy ( white powder coated ) casement handle, gi fastener 8x100 mm size for fixing frame to finish wall, plastic packer and caps and necessary steel screws etc.profile of frame and sash shall be metered cut and fusion welded at all corners, mullion shall be also fusion welded / joined mechanically including drilling of holes for fixing hardware and drainage of water etc. after fixing of frames , gap between frame and adjascent wall shall be filled with pu foaam / backer rod required size and the approved quantity. after that sealed with weather proof silicon sealant at both side, all complete as per approved drawing and direction of eic , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 1 providing and laying vitrified floor tiles in different sizes ( thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including grouting the joints with white cement and matching pigments etc., complete. size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge :flamed finish granite stone slab jet black, cherry red, elitebrown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item ( galvanised@80gsm ) 50 mm long 8mmouter diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’ , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975. the wind load shall be as per provisions of is 875 ( part iii ) . lgsfs frame shall be designed as per is: 801 using commercially available software such as frame cad pro 11.7 / staad pro v8i / architekv2.5.16 / revit architecture 2011 or equivalent. proper usage of connection accessories like heavy duty tension ties, light duty hold ons, twist straps ( to connect truss with wall frames ) , strong tie, tie rod, h brackets, boxing sections, l shaped angles for better structural stability. the framing section shall be cold form c type having minimum web depth 89 mm x 39mm flange x 11mm lip in required length as per structural design requirement duly punched with dimple / slot at required locations as per approved drawings. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm and. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , face panel providing and fixing in all exterior face panels breathable vapour barrier underneath the cementfiber board as per national building code 2009 complete as per direction of engineer in charge. , lap siding supplying and installation of moisture resistant / fire resistantlap siding 8 mm thick and width as per standard sizes made ofiber cement board with embossed decorative finish to give pleasing exterior fixed horizontally with staggered joints including minimum over lapof 32 mm external cement fibre boardconforming to is 14862:2000 offixed with self drilling / taping screws / fastners of approved make. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1 new work ( two or more coats ) over and including water tinnable priming coat with cement primer , ex. paint finishing walls with textured exterior paint of required shade : new work ( two or more coats applied @ 3.28 ltr / 10 sqm ) over and including priming coat of exterior primer applied @ 2.20kg / 10 sqm sqm , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel 1 steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , road providing and laying c.c. pavement of mix m 25 with ready mixed concrete from batching plant. the ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc.complete as per specifications and directions of engineer in charge. ( the panel shuttering work shall be paid for separately ) . ( note: cement content considered in this item is @ 330 kg / cum. excess / less cement used as per design mix is payable / recoverableseparately ) . , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 1 providing & fixing stone slab table rubbed, edges rounded and polished of size 75 x 50cm deep and 1.8 cm thick fixed in urinal patitions by cutting chase of appropriate width with chase cutter and embedding the stone in chase with epoxy grout or with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregste 6mm nominal size ) as per engineer in charge and finished smooth white agaria marble stone , phe 2 providing and fixing salem stainless steel a isi 304 ( 18 / 8 ) kitchen sink as per is: 13983 with ci brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required. kitchen sink with drain board510x1040mm bowl depth 200mm. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing:rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixturescomplete, including cutting and making good the walls andlevel whitep.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings andfloors wherever required :white vitreous china orissa pattern w.c. pan of size580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 9 providing and fixing cp brass 32mm size bottle trap of approved quality & make and as per the direction of engineer in charge.. ( sink & urinal ) , phe 10 providing & fixingptmt towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealedfittings arrangement of approved quality and colour weighing not less than 88 gms , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size 660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 15 providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water ( 250 ml & 500 ml consumption ) , having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of engineer in charge.. , phe 16 providing & fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. , phe 17 providing and fixing white vitreous china laboratory sink with c.i. brackets, c.p. brass chain with rubber plug, 40 mm c.p brass waste and 40mm c.p. brass trap with necessary c.p. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required :size 600x450x200 mm , phe 18 providing and fixing cp brass single lever telephonic wall mixer of quality & make as approved by engineer in charge . a ) 15 mm nominal dia. , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 21 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 24 two or more coats on new work over an under coat ofsuitable shade with ordinary paint of approved brand andmanufacturetwo more coast on new work , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm.clear depth and 250mm apron including cost of e / w. involved with 75mmcement concrete ( 1:4:8 ) over one brick designation 100 a flat soling inproper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 8 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia. exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 11 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 450 mm dia rcc pipe , ex. phe 12 inside size 120x90 cm and 90 cm deep including c.i. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg ) :with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , ex. phe 13 providing and fixing square mouth sw gully trap grade ‘a’ complete ci grating brick masonry chamber with bricks of class designation 75 and water tight ci cover with frame of 300 x 300 mm size ( inside ) the weight of cover to be not less than 13.00 kg and frame to be not less than 5 kg. as per standard design. ( cover min. 4.5 kg & frame min.2.7 kg ) 180x150 mm size p type with fps bricks , ex. phe 14 constructing masonry chamber 30x30x50 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement:4 coarce sand ) for stop cock complete with c.i. surface box 100x100x75mm ( inside ) with locking arrangement and rcc top slab 1:2:4 mix ( 1 cement : 2 corase sand: 4 graded stonr aggregate 20mm nominal size ) necessary excavation foundation concret 1:5:10 ( 1 cement:5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortor 1:3 ( 1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design. , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , ex. phe 16 structual steel work welded in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. , ex. phe 17 making connection of gi distribution branch with gi main of 50 80mm nominal bore by providing and fixing tee, including cutting and threading the pipe etc. complete. , rain water harvesting 1 boring / drilling bore well of required dia for casing / strainer pipe, bysuitable method prescribed in is:2800 ( part i ) , including collecting sample from different strata , preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90m depth below ground level.300 mm dia , rain water harvesting 2 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150mm nominal size dia , rain water harvesting 3 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well screen ( rms ) pipes with ribs, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150 mm nominal size dia , rain water harvesting 4 supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 5 supplying, filling, spreading & levelling gravel of size range 5mm to 10mm, in recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 7 providing and fixing bail plug / bottom plug of required dia to the bottom of pipe assembly of tube well as per is:2800 ( part i ) . 100 mm dia , rain water harvesting 8 making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and s.w. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , rain water harvesting 9 constructing soak pit 1.20x1.20x1.20 m filled with brickbats including s.w. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , tubewell 1 boring / drilling bore well of required dia for casing / strainer pipe, bysuitable method prescribed in is:2800 ( part i ) , including collecting sample from different strata , preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90m depth below ground level.300 mm dia , tubewell 2 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150mm nominal size dia , tubewell 3 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.100mm nominal size dia , tubewell 4 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well screen ( rms ) pipes with ribs, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.100 mm nominal size dia , tubewell 5 supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , tubewell 6 providing and fixing bail plug / bottom plug of required dia to the bottom of pipe assembly of tube well as per is:2800 ( part i ) . 100 mm dia , submersible pump 35m deep boring with casing and pipe. supply of pipe etc supplying & installation of suitable 2hp submersible pump b.s or k.s.bor equivalent make with finolex cable 1x3x2.5 squmm ( upto 50mtr ) withflexible conduit 25mm dia, electrical out door pannel with required electrical fitting such as mcb of 0 25amp ( havell or indocopp or mds make ) , volt & ampere meter ( ae make ) , single phase preventer ( minilac or vsp 1 make ) starter ( l&t or bch make ) etc of approved make, 40mm hdpe pipe ( 25 mtr ) and all accessories complete as per requirement of site. , water purifier and cooler 1 fitting and fixing single faucet storage type water cooler ( size 461 mm wide x 582 mm deep x 1217 mm height, weight 46 kg ) fully stainless body having storage capacity of 40 ltrs, cooling capacity of 40 ltrs. / hr. with hermetic type compressor, gas cooled motor equipped with over load protector, condensor for propeller type, thermostat autometically controlled temperature, refrigerent r 22, 230 volt, single phase 50 hertz, maximum current 2.3 amp including plug top and electrical lead wire connection upto 3 metres from the cooler, water inlet and drain out connections complete in all respects of voltas model no 40 / 40 tushar pss type or similar type of approved make. , water purifier and cooler 2 fitting and fixing water purifier for drinking purpose of capacity 6 litres / min, 5 purification system with reverse osmosis system with ultra ventilated membrane, tds500 to 2000 mgl / ppm, auto shut off with microswitch float manual flush facility, tds reduction 90% having automatic backwash system with filteration unit along with all accessories including plug top and electrical lead wire connection upto 3 metres from the purifier, water inlet and drain out connections complete in all respects similar to aquaguard or similar approved make ( model aquasure elegant ro water purifier of size width 360 mm x height 430 mm x depth 235 mm and weight 8.5 kg ) . , fire extinguisher 1 providing and fixing carbon di oxide type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. capacity 4.5 kg. , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 6.0 kg. , electrical 1 wiring for light point / fan point / exhaust fan point / call bellpoint with 1.5 sq.mm frls pvc insulated copper conductorsingle core cable in surface / recessed steel conduit, withmodular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. group c , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , pvc conduit 1 supplying and fixing of following sizes of medium class 20mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , pvc conduit 2 supplying and fixing of following sizes of medium class 32mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , pvc conduit 3 supplying and fixing of following sizes of medium class 50mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , electrical 4 wiring for light / power plug with 2x4 sq. mm frls pvcinsulated copper conductor single core cable in surface / recessed conduit alongwith 1 no. 4 sq. mm frls pvcinsulated copper conductor single core cable for loop earthingas required. , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 4 x 6 sq. mm + 2 x 6 sq. mm earth wire , wiring frls pvc insulated copper conductor 4 4 x 10 sq. mm + 2 x 6 sq. mm earth wire , wiring frls pvc insulated copper conductor 5 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 1 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 3 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 4 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 2 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 3 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 4 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 5 telephone socket outlet , s / f modular switch / socket on the existing modular plate 6 tv antenna socket outlet , s / f modular switch / socket on the existing modular plate 7 bell push , electrical 5 supplying & fixing suitable size gi box wih modular plate and cover in front on surface or in recess including providing and fixing 25 a modular socket outlet and 25 a modular sp mcb, “c” curve including connections, painting etc. as required. ( for ac / geyser ) , electrical 6 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface / recessed steel / pvc conduit as required. , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 11 supplying and fixing 20 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. , electrical 12 supplying and fixing 30 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , electrical 14 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 12 way , double door , electrical 15 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 16 way, double door , electrical 16 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 6 way ( 4 + 18 ) , double door , electrical 17 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way ( 4 + 24 ) , double door , electrical 18 supplying and fixing of following ways surface / recess mounting, vertical type, 415 v, tpn mcb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 a tinned copper bus bar, common neutral link, earth bar, din bar for mounting mcbs ( but without mcbs and incomer ) as required . ( note : vertical type mcb tpdb is normally usedwhere 3 phase outlets are required. ) 4 way ( 4 + 12 ) , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 63a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 100a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , l / f pvc sheathed / xlpe power cable in trench laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 95 sq. mm and upto 185 sq. mm , l / f pvc sheathed / xlpe power cable in trench 1 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 185 sq. mm and upto 400 sq. mm , l / f pvc sheathed / xlpe power cable over cable tray upto 35 sq. mm ( clamped with 1mm thick saddle ) , l / f pvc sheathed / xlpe power cable over cable tray 2 above 35 sq. mm and upto 95 sq. mm ( clamped with 25x3mm ms flat clamp ) , l / f pvc sheathed / xlpe power cable over cable tray 3 above 95 sq. mm and upto 185 sq. mm ( clamped with 25 / 40x3mm ms flat clamp ) , l / f pvc sheathed / xlpe power cable over cable tray 4 above 185 sq. mm and upto 400 sq. mm ( clamped with 40x3mm ms flat clamp ) , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 3.5c x 300 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 1 3.5c x 240 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 2 3.5c x 120 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 3 3.5c x 95 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 4 3.5c x 50 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 5 4c x 35 sqmm aluminium conductor cable a2xfy , cable tray supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 100 mm width x 50 mm depth x 1.6 mm thickness , cable tray 1 supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 300 mm width x 50 mm depth x 1.6 mm thickness , cable tray 2 supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 600 mm width x 62.5 mm depth x 2.0 mm thickness , cable tray “bends” supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.100 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 1 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.150 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 2 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.300 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 3 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.450 mm width x 50 mm depth x 2 mm thickness , cable tray “bends” 4 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.600 mm width x 62.5 mm depth x 2.0 mm thickness , mv cable supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 300 sqmm, aluminium conductor cable a2xfy , mv cable 1 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 240 sqmm, aluminium conductor cable a2xfy , mv cable 2 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 120 sqmm, aluminium conductor cable a2xfy , mv cable 3 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 95 sqmm, aluminium conductor cable a2xfy , earthing earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 1 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. , earthing 2 earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. , earthing 3 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 4 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , earthing 5 providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required. , earthing 6 providing and fixing earth bus of 50 mm x 5 mm copper strip on surface for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 4 supplying and fixing recess mounted 12 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 6 supply, installation, testing and commissioning of 400 mm sweep, 65w, blade material aluminium blades , speed & oscillation 3 speed, pull cord for speed and oscillation.air delivery minimum 72 m³ / min, speed minimun 1350 revolution per minute.suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , fiting & fixtures 8 supplying installation testing & commissioning ofb22 based 9w led 3 star bulb with 850 lumen, 6k color temperature including holder. , fiting & fixtures 9 supplying installation testing & commissioning of black painted extruded aluminium housing. green / red led’s mounted inside the housing. laser engraved signage matter on single / double acrylic sheet fixed on one side suitable for wall / ceiling / suspension type single / double sided display. in double sided version black paper is inserted. ni cd battery back up to 2 hrs. ( charged up to 8 10 hrs ) .mounting strings provided for pendent mounting operating voltage 150 280v ac ambient operating temperature. – 0 to 450c ingress protection – ip42.including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required.   220208 besl 03 led ssd wbb green 240 3 8wor220209 besl 03 led ssd wbb red 240 3 8wor220210 besl 03 led dsd wbb green 240 3 8wor220211 besl 03 led dsd wbb red 240 3 8w , fiting & fixtures 10 supply, installation, testing & erecting of ip66 bulkhead surface type lighting fixture 10w made up of pressure die cast aluminium housing and polyster powder coated die cast aluminium with high quality polycarbonate diffuser in opal finish for glare free light distribution.high efficiency long life led module with smd led package mounted on mcpcb with lumen efficacy of >95 lm / w with system lumen 950. powered by integral electronic led driver with apfc with low thd output short / open circuit protection. cct 5700, cri>80, system efficacy>90lm / w, thd<15%, pf>.95, ip66, ik 10, life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz.including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. cat ref: havells : hexaft10wled857ssymbopc or approved equivalent. , civil & misc works1 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. , civil & misc works2 providing and fixing h.t. danger notice plate of 250 mm x 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. , civil & misc works3 supplying and making cable route marker with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm x 60 cm at the bottom and 50 cm x 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. , civil & misc works4 supplying and fixing cable route marker with 10 cm x 10 cm x 5 mm thick g.i. plate with inscription there on, bolted / welded to 35 mm x 35 mm x 6 mm angle iron, 60 cm long and fixing the same in ground as required. , civil & misc works5 providing & fixing in position 1000 mm wide , electrical insulating rubber mats as per is 15652:2006, 2 mm thick, suitable up to 1.1 kv , fire retardant, no effect of acids, alkalis and transformer oils, moisture proof, high tensile strengthandtexture finish / cloth impression ( anti slip , marking on top ) , civil & misc works6 supply & fixing shock treatment chart duly mounted on a wooden frame with 5 mm thick glass as required ( approx front area 1.20 sq metre ) , 40 kvaups supplying, installation, testing and commissioningof online double conversion fully microprocessor based , indoor type, compact ups system of following rating with igbt based pwm technology to achieve thd < 3% and input power factor of greater than 0.95 at 50% loading, suitable for three phase ac input voltage 380 v to 440 v, 50 hz +3% / 3 % and three phase ac output voltage 415 ± 1% volts & frequency 50 ± 0.5 hz , inbuilt isolation transformer, necessary vrla batteries of suitable size having 30 minutes back up time , mounting rack including and suitable size connecting cable ( for ups to battery and battery to battery ) , static and maintenance bypass switch, snmp card for rs232 / ethernet ip computability for operation and monitoring etc. with all components as mentioned , specifications, complete as required.note : concerning vendor needs to furnish the battery sizing calculations at the time of ga approval and battery size has to be as per the approved ga drawing. , external lighting 1 supply and erection of 4 metre height hot dipgalvanized octagonal street light pole with followingarm with top dia 70 mm and bottom dia a / f 130 mm, made of 3 mm thick sheet along with base plate of size220 x 220 x 12 mm , small door opening for junctionbox mounting with mcb & connector, cement concreteof 1:3:6 including excavation, refilling and suitable sizefoundation bolts with template and all complete jobasrequired. ( but without pole collar ) single arm , external lighting 2 supplying and fixing 40 / 45 watt led type street lightwith die cast aluminium housing for ingress protectionof ip65 and complete with all accessories etc, onpole / building including connection with fr pvcinsulated copper conductor cable and earthing thebody etc. as required. , ip based cctv system 1 sitc of 2 megapixel @ 25fps, h.265 ip bullet camera, 1 / 2.9 cmos with 2.8~12mm varifocal lens, 0 lux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 2 sitc of 2 megapixel @ 25fps, h.265 ip dome camera, 1 / 2.9 cmos with 3.6 fixed mm 0 lux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 3 sitc of 2 megapixel @ 25fps, ptz camera h.265 ip dome camera, 1 / 2.9 cmos with 2.6 fixed lenslux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 4 sitc of 32ch 4k ivr , h.265 / h.264 • 1080p real time • 4k display • dual lan • 8x hdd • raid •web plugin free h.265 / h.264 compression technology 4k display for clear monitoring up to 1080p 16ch decoding ability smart search ii smart vca event searchsupport raid 0, 1, 5 supported to prevent from recording data loss browsers supported: ie , smart functions : target count, electric fence, face detection, humaniod detection, retrograde detection, leave position detectio output, local & network backup etc. complete as required. , cctv 5 sitc of harddiskdrive8tb, 24 / 7surveillance category only complete etc as required.etc.all complete , cctv 6 sitc of 55 led narrow bazel for monitoring for nvr server etc. all complete. , cctv 7 sitc of rj 45 outlets near the cameras etc. all complete. etc. all complete. , cctv 8 sitc of cat 6 patch cords 1 meter high quality four pair twisted stranded cable terminated with rj45 modular plugs at both the ends. , signage 1 providing & fixing of building direction signage mounted on pole, with pole of 100x100mm shs ( square hollow section ) of height of 5600mm, and sign size of 900x1050, sign made of aluminiu c section of 60mm with internal framing to support the frame in ms tubes hollow section, frame work duly painted with anti rust coatings, with facia of 3mm thick exterior grade aluminium composite panel, cladded with uv cured digital printed retroreflective sheet of 3m make, and back panel of 3mm exterior grade acp, all pipes to be painted in approved color. cost shall includecost towards installation, including excuvation and filling up with specified pcc and fixing of foundation bolts as specified, also it shall include the designing charges.all complete as per direction by engineer in charge. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , 2 tr air conditioning 1 split ac ( inverter model ) : supply, installation, testing, commissioning of split type wall mounted air conditioning units of following capacity including inddor, outdoor unit fitted with inverter based rotary compressor fitted with rotary compressor, copper condensor and first charge refrigent r410a / eco friendly green gas only, all complete including all electrical connections to the electrical power supply system of the building, includingbut not limited to supply of all electrical plugs, etc., as necessary, lengthening of all electrical wires of ac units ( both indoor and outdoor ) , drain pipe andincluding suitable voltage stabilisers, etc. so as to place them in a concealed manner in the desired position. the copper pipes and electrical cables shall be concealed in approved manner and neatly run in straight lines in a workman like manner with proper supports. complete supply and installation of split2 tr star rating 3 star , refrigerant piping copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 25 mm od, wall thickness >= 1.2 mm ( insulation 19 mm thick ) , refrigerant piping 1 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 19.1 mm od, wall thickness >= 1.0 mm ( insulation 13 mm thick ) , refrigerant piping 2 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 15.9 mm od, wall thickness >= 0.8 mm ( insulation 13 mm thick ) , refrigerant piping 3 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 9.5 mm od, wall thickness >= 0.8 mm ( insulation 13 mm thick ) , drain piping providing and fixing of cpvc 6 kg / cm2 drainpiping complete with fittings, supports, 6 mm thick closed cell elastomeric insulation as per specifications and drawings. 20 mm , drain piping 1 providing and fixing of cpvc 6 kg / cm2 drainpiping complete with fittings, supports, 6 mm thick closed cell elastomeric insulation as per specifications and drawings. 32 mm , main oxygen manifold supply, installation, testing and commissioning of following gas manifold system ( excluding cylinders ) . the manifold is configured for designed numbers of cylinders and is suitable to withstand a pressure of 145 kg / cm2, along withhigh pressure copper annealed tail pipes with end brass adapter suitable for cylinders and manifold. top frame comprising of high pressure copper pipes of size 1 / 2” nb x 15swg with high pressure brass fittings made of high tensile brass and connections through nonreturn valves, the design of middle and bottomframes is provided to fit both round and flat bottom cylinders safely. the manifold is tested ( hydraulically ) at 3500 psig. ( it should be ce and iso 13485 certified ) mani fold oxygen manifold 6 + 6 cylinder banks complete with nrv, middle frame, bottom frame with ce marked, , emergency manifold emergency oxygen manifold 01 + 01 cylinder emergency manifold with complete regulator, nrv, middle frame & bottom frame, , control panelfor oxygen fully automatic three port control panel for oxygen supply, installation, testing and commissioning of automatic manifold control panel would provide a duty or standby gas supply from two cylinder banks with automaticchangeover the manifold indicates local status and has a remote indicator facility. automaticmanifold control panel would be designed to supply the mgps with a constant pressure supply via a control panel form two equal banks of cylinders and the changeover from the ‘duty’ to the ‘standby’ bank of cylinders would beautomatic. automatic changeover from the duty to the standby bank would occur at a cylinder pressure that will ensure the maximum usage of the contents of the duty bank. the changeover unit would be provided with monitoring todetect and display: duty bank operating, duty bank empty, standby bank operating, and standby bank below 10 % when the duty bank is empty, reserve bank low, pipeline pressure fault. there would be facility to connect liquidoxygen supply ( i.e. three port control panel ) ( it should be ce and iso 13485 certified ) fully automatic three port control panel for oxygen , emergency manifold line regulator emergency manifold line regulator supply, installation, testing and commissioning of emergency manifold line regulator i n p u t p r e s s u r e 1 5 0 k g / c m 2 working pressure 4 kg / cm2 it should be ce and iso 13485 certified.oxygen input pressure 150 kg / cm2 working pressure 4 kg / cm2capacity : 1500 lpm , cylinderconnectingpipe ( pig tail ) supply, installation, testing and commissioning of cylinder connecting pipe ( pig tail ) made up of flexible ss hose with safety cord 5 / 8 inch bsp gland nut and one side 1 / 2 inch bsp internal threads having one meter length. ( oxygen 24 , n2o 10, co2 4 ) , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , medical air ( 4 bar ) outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve, supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified.42mm , isolation valve 2 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 28mm , isolation valve 3 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 22mm , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness , pipeline 4 medical grade copper pipeline ( in mtrs. ) as per en 13348, 28 mm ( od ) x 0.9 mm thickness , pipeline 5 medical grade copper pipeline ( in mtrs. ) as per en 13348, 42 mm ( od ) x 1.2 mm thickness , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 2268 mm x ( w ) 922 mm x ( h ) 610 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , paediatric bed with mattress paediatric bed of overall sizes in mm: 1500 ( l ) x 850 ( w ) x 1210 ( h ) flat single section bed with grille frame on 4 sides.suitable for children up to 12 years.drop down grill frame on both sides for protection of the patient.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral white , bed side locker type i over all dimension :402mmlx422mm wx840mm ht .locker should have one cabinet and one drawer unit .both provided with cam lock .there should be gap between drawer and unit to keep general items for frequesnt use castors are provided for easy handling .drawer made up of crca sheet 1 mm thick and has ball slide for easy operation .top ss 304 sheet 0.8 mm thick castors 50 mmdia , hamdle abs ..powder coating of epoxy polyester , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , strecher on trolley type i 2005mm ( l ) x666mm ( w ) x827mm ( h ) .the trolley should be made of 31.75 and 25.4 mm dia 1.6 mm thick erw tube.holder for stretcher should be made up of mild steel.castor should be of 200 mm dia , diagonal locking castor.stretcher should be made up oferw tubeof dia 25.4 mm and thickness 1.6 mm.top sheet should be made of crca sheetof thickness 1.2 mm with contour shape to accommodate patient.iv pole holder should be made ofms .maximum safe work load should be 135 kg.to ensure qood quality welding co2 argonprocess should be adhered to.all metal componentsshould be pre treated with zinc phosphating in 9 tank porcess and then powder coated with anti microbialepoxy polyster powder coating.goods should be supplied in knocked down construction to reduce carbon emission. performance test :proof loading test , cycle tests , impact test, salt spray test, castor break test, the manufacturer should compilant with iso 9001, 14001, 13485, ohsas 1800 and ce certification. , doctor desk type x s / f / f executive table main desk should be of dimesion : 1350w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. side panels : ( black ) made form 18mm thick plt with pvc lipping.modesty panel : made form 18mm thick plt with pvc lipping. bigger upper panel in black and smaller lower panel in white cedar. made from 18mm thick plt with pvc lipping. mobile pedestal : one box and one filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , chair type iii s / f / f executive chair1 ) seat / back assembly: the seat and back are made up of 1.2 cm. thick hot pressed plywood, upholstered withfabric upholstery covers and moulded polyurethane foam. the back foam is designed with contoured lumbar support for extra comfort. the seat has extra thick foam on front edge to give comfort to popliteal area.high back size : 47.5 cm ( w ) x 69.5 cm ( h ) seat size : 47.0 cm. ( w ) x 48.0 cm. ( d ) 2 ) polyurethane foam: the polyurethane foam is moulded with density = 45 + / 2 kg / m 3and hardness = 20 + / 2at 25% compression. 3 ) armrests: the one piece armrests are injection moulded from black co polymer polypropylene. 4 ) center tilt synchro mechanism : the mechanism is designed with the following features:• 360 revolving type. • upright position locking. • tilt tension adjustment.• seat / back tilting ratio of 1:3 ( 60 seat tilt / 180 back tilt ) . 5 ) pneumatic height adjustment : the pneumatic height adjustment has anadjustment stroke of 12.0 cm. 6 ) telescopic bellow assembly : the bellow is 3 piece telescopic type and injection moulded in black polypropylene. 7 ) pedestal assembly : . , staff / visitor chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck .3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement.mx load bearing capacity should be 10 kg. , hospital curtain tracks & i.v. tree system supply installation testing & commissioning of cubical tracks system made of powder coated aluminium alloy, stain free polyster fabric , water repellent curtains , smooth movement , non sticking runnner with stainless steel hooks made from mirror finish stainless steel , adjustable height with all accessories. total quantity : 1...

Health And Family Welfare Department - Bihar

30456419 bids are invited for pile boring, providing and installation bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using direct mud circulation ( dmc ) or bailer and chisel technique by tripod and mechanical winch machine all complete, including removal of excavated earth with all its lifts and leads ( length of pile for payment shall be measured up to bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , upvc door providing and fixing of factory made upvc white colour casement door, upvc multichambered extruted frame, sash and mullion profile. frame duly reinforced with 1.2mm gi section box tpe chamber and sash with 1.5mm thick gi section ( ± 0.2mm ) based on wind load calculations ( shape and size according to upvc profiles ) , appropiate dimentions of upvc extruded glazing bead, epdm gasket ( k / o type ) , seperate drainage system, ss34 grade friction hinges 2d / 3d plate hinges, zinc alloy ( white powder coated ) casement handle, gi fastener 8x100 mm size for fixing frame to finish wall, plastic packer and caps and necessary steel screws etc.profile of frame and sash shall be metered cut and fusion welded at all corners, mullion shall be also fusion welded / joined mechanically including drilling of holes for fixing hardware and drainage of water etc. after fixing of frames , gap between frame and adjascent wall shall be filled with pu foaam / backer rod required size and the approved quantity. after that sealed with weather proof silicon sealant at both side, all complete as per approved drawing and direction of eic , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 1 providing and laying vitrified floor tiles in different sizes ( thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including grouting the joints with white cement and matching pigments etc., complete. size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge :flamed finish granite stone slab jet black, cherry red, elitebrown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item ( galvanised@80gsm ) 50 mm long 8mmouter diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’ , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975. the wind load shall be as per provisions of is 875 ( part iii ) . lgsfs frame shall be designed as per is: 801 using commercially available software such as frame cad pro 11.7 / staad pro v8i / architekv2.5.16 / revit architecture 2011 or equivalent. proper usage of connection accessories like heavy duty tension ties, light duty hold ons, twist straps ( to connect truss with wall frames ) , strong tie, tie rod, h brackets, boxing sections, l shaped angles for better structural stability. the framing section shall be cold form c type having minimum web depth 89 mm x 39mm flange x 11mm lip in required length as per structural design requirement duly punched with dimple / slot at required locations as per approved drawings. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm and. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , face panel providing and fixing in all exterior face panels breathable vapour barrier underneath the cementfiber board as per national building code 2009 complete as per direction of engineer in charge. , lap siding supplying and installation of moisture resistant / fire resistantlap siding 8 mm thick and width as per standard sizes made ofiber cement board with embossed decorative finish to give pleasing exterior fixed horizontally with staggered joints including minimum over lapof 32 mm external cement fibre boardconforming to is 14862:2000 offixed with self drilling / taping screws / fastners of approved make. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1 new work ( two or more coats ) over and including water tinnable priming coat with cement primer , ex. paint finishing walls with textured exterior paint of required shade : new work ( two or more coats applied @ 3.28 ltr / 10 sqm ) over and including priming coat of exterior primer applied @ 2.20kg / 10 sqm sqm , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel 1 steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , road providing and laying c.c. pavement of mix m 25 with ready mixed concrete from batching plant. the ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc.complete as per specifications and directions of engineer in charge. ( the panel shuttering work shall be paid for separately ) . ( note: cement content considered in this item is @ 330 kg / cum. excess / less cement used as per design mix is payable / recoverableseparately ) . , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 1 providing & fixing stone slab table rubbed, edges rounded and polished of size 75 x 50cm deep and 1.8 cm thick fixed in urinal patitions by cutting chase of appropriate width with chase cutter and embedding the stone in chase with epoxy grout or with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregste 6mm nominal size ) as per engineer in charge and finished smooth white agaria marble stone , phe 2 providing and fixing salem stainless steel a isi 304 ( 18 / 8 ) kitchen sink as per is: 13983 with ci brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required. kitchen sink with drain board510x1040mm bowl depth 200mm. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing:rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixturescomplete, including cutting and making good the walls andlevel whitep.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings andfloors wherever required :white vitreous china orissa pattern w.c. pan of size580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 9 providing and fixing cp brass 32mm size bottle trap of approved quality & make and as per the direction of engineer in charge.. ( sink & urinal ) , phe 10 providing & fixingptmt towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealedfittings arrangement of approved quality and colour weighing not less than 88 gms , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size 660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 15 providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water ( 250 ml & 500 ml consumption ) , having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of engineer in charge.. , phe 16 providing & fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. , phe 17 providing and fixing white vitreous china laboratory sink with c.i. brackets, c.p. brass chain with rubber plug, 40 mm c.p brass waste and 40mm c.p. brass trap with necessary c.p. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required :size 600x450x200 mm , phe 18 providing and fixing cp brass single lever telephonic wall mixer of quality & make as approved by engineer in charge . a ) 15 mm nominal dia. , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 21 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 24 two or more coats on new work over an under coat ofsuitable shade with ordinary paint of approved brand andmanufacturetwo more coast on new work , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm.clear depth and 250mm apron including cost of e / w. involved with 75mmcement concrete ( 1:4:8 ) over one brick designation 100 a flat soling inproper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 8 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia. exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 11 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 450 mm dia rcc pipe , ex. phe 12 inside size 120x90 cm and 90 cm deep including c.i. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg ) :with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , ex. phe 13 providing and fixing square mouth sw gully trap grade ‘a’ complete ci grating brick masonry chamber with bricks of class designation 75 and water tight ci cover with frame of 300 x 300 mm size ( inside ) the weight of cover to be not less than 13.00 kg and frame to be not less than 5 kg. as per standard design. ( cover min. 4.5 kg & frame min.2.7 kg ) 180x150 mm size p type with fps bricks , ex. phe 14 constructing masonry chamber 30x30x50 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement:4 coarce sand ) for stop cock complete with c.i. surface box 100x100x75mm ( inside ) with locking arrangement and rcc top slab 1:2:4 mix ( 1 cement : 2 corase sand: 4 graded stonr aggregate 20mm nominal size ) necessary excavation foundation concret 1:5:10 ( 1 cement:5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortor 1:3 ( 1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design. , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , ex. phe 16 structual steel work welded in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. , ex. phe 17 making connection of gi distribution branch with gi main of 50 80mm nominal bore by providing and fixing tee, including cutting and threading the pipe etc. complete. , rain water harvesting 1 boring / drilling bore well of required dia for casing / strainer pipe, bysuitable method prescribed in is:2800 ( part i ) , including collecting sample from different strata , preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90m depth below ground level.300 mm dia , rain water harvesting 2 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150mm nominal size dia , rain water harvesting 3 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well screen ( rms ) pipes with ribs, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150 mm nominal size dia , rain water harvesting 4 supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 5 supplying, filling, spreading & levelling gravel of size range 5mm to 10mm, in recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 7 providing and fixing bail plug / bottom plug of required dia to the bottom of pipe assembly of tube well as per is:2800 ( part i ) . 100 mm dia , rain water harvesting 8 making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and s.w. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , rain water harvesting 9 constructing soak pit 1.20x1.20x1.20 m filled with brickbats including s.w. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , tubewell 1 boring / drilling bore well of required dia for casing / strainer pipe, bysuitable method prescribed in is:2800 ( part i ) , including collecting sample from different strata , preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90m depth below ground level.300 mm dia , tubewell 2 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150mm nominal size dia , tubewell 3 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.100mm nominal size dia , tubewell 4 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well screen ( rms ) pipes with ribs, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.100 mm nominal size dia , tubewell 5 supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , tubewell 6 providing and fixing bail plug / bottom plug of required dia to the bottom of pipe assembly of tube well as per is:2800 ( part i ) . 100 mm dia , submersible pump 35m deep boring with casing and pipe. supply of pipe etc supplying & installation of suitable 2hp submersible pump b.s or k.s.bor equivalent make with finolex cable 1x3x2.5 squmm ( upto 50mtr ) withflexible conduit 25mm dia, electrical out door pannel with required electrical fitting such as mcb of 0 25amp ( havell or indocopp or mds make ) , volt & ampere meter ( ae make ) , single phase preventer ( minilac or vsp 1 make ) starter ( l&t or bch make ) etc of approved make, 40mm hdpe pipe ( 25 mtr ) and all accessories complete as per requirement of site. , water purifier and cooler fitting and fixing single faucet storage type water cooler ( size 461 mm wide x 582 mm deep x 1217 mm height, weight 46 kg ) fully stainless body having storage capacity of 40 ltrs, cooling capacity of 40 ltrs. / hr. with hermetic type compressor, gas cooled motor equipped with over load protector, condensor for propeller type, thermostat autometically controlled temperature, refrigerent r 22, 230 volt, single phase 50 hertz, maximum current 2.3 amp including plug top and electrical lead wire connection upto 3 metres from the cooler, water inlet and drain out connections complete in all respects of voltas model no 40 / 40 tushar pss type or similar type of approved make. , water purifier and cooler 1 fitting and fixing water purifier for drinking purpose of capacity 6 litres / min, 5 purification system with reverse osmosis system with ultra ventilated membrane, tds500 to 2000 mgl / ppm, auto shut off with microswitch float manual flush facility, tds reduction 90% having automatic backwash system with filteration unit along with all accessories including plug top and electrical lead wire connection upto 3 metres from the purifier, water inlet and drain out connections complete in all respects similar to aquaguard or similar approved make ( model aquasure elegant ro water purifier of size width 360 mm x height 430 mm x depth 235 mm and weight 8.5 kg ) . , fire extinguisher 1 providing and fixing carbon di oxide type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. capacity 4.5 kg. , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 6.0 kg. , electrical 1 wiring for light point / fan point / exhaust fan point / call bellpoint with 1.5 sq.mm frls pvc insulated copper conductorsingle core cable in surface / recessed steel conduit, withmodular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. group c , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , pvc conduit 1 supplying and fixing of following sizes of medium class 20mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , pvc conduit 2 supplying and fixing of following sizes of medium class 32mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , pvc conduit 3 supplying and fixing of following sizes of medium class 50mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , electrical 4 wiring for light / power plug with 2x4 sq. mm frls pvcinsulated copper conductor single core cable in surface / recessed conduit alongwith 1 no. 4 sq. mm frls pvcinsulated copper conductor single core cable for loop earthingas required. , wiring frls pvc insulated copper conductor 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 1 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 2 4 x 6 sq. mm + 2 x 6 sq. mm earth wire , wiring frls pvc insulated copper conductor 3 4 x 10 sq. mm + 2 x 6 sq. mm earth wire , wiring frls pvc insulated copper conductor 4 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 1 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 3 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 4 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 1 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 2 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 3 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 4 telephone socket outlet , s / f modular switch / socket on the existing modular plate 5 tv antenna socket outlet , s / f modular switch / socket on the existing modular plate 6 bell push , electrical 5 supplying & fixing suitable size gi box wih modular plate and cover in front on surface or in recess including providing and fixing 25 a modular socket outlet and 25 a modular sp mcb, “c” curve including connections, painting etc. as required. ( for ac / geyser ) , electrical 6 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface / recessed steel / pvc conduit as required. , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 11 supplying and fixing 20 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. , electrical 12 supplying and fixing 30 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , electrical 14 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 12 way , double door , electrical 15 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 16 way, double door , electrical 16 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 6 way ( 4 + 18 ) , double door , electrical 17 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way ( 4 + 24 ) , double door , electrical 18 supplying and fixing of following ways surface / recess mounting, vertical type, 415 v, tpn mcb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 a tinned copper bus bar, common neutral link, earth bar, din bar for mounting mcbs ( but without mcbs and incomer ) as required . ( note : vertical type mcb tpdb is normally usedwhere 3 phase outlets are required. ) 4 way ( 4 + 12 ) , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 63a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 100a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , l / f pvc sheathed / xlpe power cable in trench laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 95 sq. mm and upto 185 sq. mm , l / f pvc sheathed / xlpe power cable in trench 1 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 185 sq. mm and upto 400 sq. mm , l / f pvc sheathed / xlpe power cable over cable tray 2 upto 35 sq. mm ( clamped with 1mm thick saddle ) , l / f pvc sheathed / xlpe power cable over cable tray 3 above 35 sq. mm and upto 95 sq. mm ( clamped with 25x3mm ms flat clamp ) , l / f pvc sheathed / xlpe power cable over cable tray 4 above 95 sq. mm and upto 185 sq. mm ( clamped with 25 / 40x3mm ms flat clamp ) , l / f pvc sheathed / xlpe power cable over cable tray 5 above 185 sq. mm and upto 400 sq. mm ( clamped with 40x3mm ms flat clamp ) , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 3.5c x 300 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 1 3.5c x 240 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 2 3.5c x 120 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 3 3.5c x 95 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 4 3.5c x 50 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 5 4c x 35 sqmm aluminium conductor cable a2xfy , cable tray 1 supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 100 mm width x 50 mm depth x 1.6 mm thickness , cable tray 2 supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 300 mm width x 50 mm depth x 1.6 mm thickness , cable tray 3 supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 600 mm width x 62.5 mm depth x 2.0 mm thickness , cable tray “bends” supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.100 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 1 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.150 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 2 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.300 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends”3 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.450 mm width x 50 mm depth x 2 mm thickness , cable tray “bends” 4 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.600 mm width x 62.5 mm depth x 2.0 mm thickness , mv cable supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 300 sqmm, aluminium conductor cable a2xfy , mv cable 1 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 240 sqmm, aluminium conductor cable a2xfy , mv cable 2 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 120 sqmm, aluminium conductor cable a2xfy , mv cable 3 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 95 sqmm, aluminium conductor cable a2xfy , earthing 1 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 2 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. , earthing 3 earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. , earthing 4 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 5 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , earthing 6 providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required. , earthing 7 providing and fixing earth bus of 50 mm x 5 mm copper strip on surface for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : , fiting & fixtures 4 supplying and fixing recess mounted 12 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 6 supply, installation, testing and commissioning of 400 mm sweep, 65w, blade material aluminium blades , speed & oscillation 3 speed, pull cord for speed and oscillation.air delivery minimum 72 m³ / min, speed minimun 1350 revolution per minute.suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , fiting & fixtures 8 supplying installation testing & commissioning ofb22 based 9w led 3 star bulb with 850 lumen, 6k color temperature including holder. , fiting & fixtures 9 supplying installation testing & commissioning of black painted extruded aluminium housing. green / red led’s mounted inside the housing. laser engraved signage matter on single / double acrylic sheet fixed on one side suitable for wall / ceiling / suspension type single / double sided display. in double sided version black paper is inserted. ni cd battery back up to 2 hrs. ( charged up to 8 10 hrs ) .mounting strings provided for pendent mounting operating voltage 150 280v ac ambient operating temperature. – 0 to 450c ingress protection – ip42.including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required.   220208 besl 03 led ssd wbb green 240 3 8wor220209 besl 03 led ssd wbb red 240 3 8wor220210 besl 03 led dsd wbb green 240 3 8wor220211 besl 03 led dsd wbb red 240 3 8w , fiting & fixtures 10 supply, installation, testing & erecting of ip66 bulkhead surface type lighting fixture 10w made up of pressure die cast aluminium housing and polyster powder coated die cast aluminium with high quality polycarbonate diffuser in opal finish for glare free light distribution.high efficiency long life led module with smd led package mounted on mcpcb with lumen efficacy of >95 lm / w with system lumen 950. powered by integral electronic led driver with apfc with low thd output short / open circuit protection. cct 5700, cri>80, system efficacy>90lm / w, thd<15%, pf>.95, ip66, ik 10, life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz.including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. cat ref: havells : hexaft10wled857ssymbopc or approved equivalent. , civil & misc works1 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. , civil & misc works2 providing and fixing h.t. danger notice plate of 250 mm x 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. , civil & misc works3 supplying and making cable route marker with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm x 60 cm at the bottom and 50 cm x 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. , civil & misc works4 supplying and fixing cable route marker with 10 cm x 10 cm x 5 mm thick g.i. plate with inscription there on, bolted / welded to 35 mm x 35 mm x 6 mm angle iron, 60 cm long and fixing the same in ground as required. , civil & misc works5 providing & fixing in position 1000 mm wide , electrical insulating rubber mats as per is 15652:2006, 2 mm thick, suitable up to 1.1 kv , fire retardant, no effect of acids, alkalis and transformer oils, moisture proof, high tensile strengthandtexture finish / cloth impression ( anti slip , marking on top ) , civil & misc works6 supply & fixing shock treatment chart duly mounted on a wooden frame with 5 mm thick glass as required ( approx front area 1.20 sq metre ) , 40 kvaups supplying, installation, testing and commissioningof online double conversion fully microprocessor based , indoor type, compact ups system of following rating with igbt based pwm technology to achieve thd < 3% and input power factor of greater than 0.95 at 50% loading, suitable for three phase ac input voltage 380 v to 440 v, 50 hz +3% / 3 % and three phase ac output voltage 415 ± 1% volts & frequency 50 ± 0.5 hz , inbuilt isolation transformer, necessary vrla batteries of suitable size having 30 minutes back up time , mounting rack including and suitable size connecting cable ( for ups to battery and battery to battery ) , static and maintenance bypass switch, snmp card for rs232 / ethernet ip computability for operation and monitoring etc. with all components as mentioned , specifications, complete as required.note : concerning vendor needs to furnish the battery sizing calculations at the time of ga approval and battery size has to be as per the approved ga drawing. , external lighting 1 supply and erection of 4 metre height hot dipgalvanized octagonal street light pole with followingarm with top dia 70 mm and bottom dia a / f 130 mm, made of 3 mm thick sheet along with base plate of size220 x 220 x 12 mm , small door opening for junctionbox mounting with mcb & connector, cement concreteof 1:3:6 including excavation, refilling and suitable sizefoundation bolts with template and all complete jobasrequired. ( but without pole collar ) single arm , external lighting 2 supplying and fixing 40 / 45 watt led type street lightwith die cast aluminium housing for ingress protectionof ip65 and complete with all accessories etc, onpole / building including connection with fr pvcinsulated copper conductor cable and earthing thebody etc. as required. , ip based cctv system 1 sitc of 2 megapixel @ 25fps, h.265 ip bullet camera, 1 / 2.9 cmos with 2.8~12mm varifocal lens, 0 lux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 2 sitc of 2 megapixel @ 25fps, h.265 ip dome camera, 1 / 2.9 cmos with 3.6 fixed mm 0 lux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 3 sitc of 2 megapixel @ 25fps, ptz camera h.265 ip dome camera, 1 / 2.9 cmos with 2.6 fixed lenslux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 4 sitc of 32ch 4k ivr , h.265 / h.264 • 1080p real time • 4k display • dual lan • 8x hdd • raid •web plugin free h.265 / h.264 compression technology 4k display for clear monitoring up to 1080p 16ch decoding ability smart search ii smart vca event searchsupport raid 0, 1, 5 supported to prevent from recording data loss browsers supported: ie , smart functions : target count, electric fence, face detection, humaniod detection, retrograde detection, leave position detectio output, local & network backup etc. complete as required. , cctv 5 sitc of harddiskdrive8tb, 24 / 7surveillance category only complete etc as required.etc.all complete , cctv 6 sitc of 55 led narrow bazel for monitoring for nvr server etc. all complete. , cctv 7 sitc of rj 45 outlets near the cameras etc. all complete. etc. all complete. , cctv 8 sitc of cat 6 patch cords 1 meter high quality four pair twisted stranded cable terminated with rj45 modular plugs at both the ends. , signage 1 providing & fixing of building direction signage mounted on pole, with pole of 100x100mm shs ( square hollow section ) of height of 5600mm, and sign size of 900x1050, sign made of aluminiu c section of 60mm with internal framing to support the frame in ms tubes hollow section, frame work duly painted with anti rust coatings, with facia of 3mm thick exterior grade aluminium composite panel, cladded with uv cured digital printed retroreflective sheet of 3m make, and back panel of 3mm exterior grade acp, all pipes to be painted in approved color. cost shall includecost towards installation, including excuvation and filling up with specified pcc and fixing of foundation bolts as specified, also it shall include the designing charges.all complete as per direction by engineer in charge. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , 2 tr air conditioning 1 split ac ( inverter model ) : supply, installation, testing, commissioning of split type wall mounted air conditioning units of following capacity including inddor, outdoor unit fitted with inverter based rotary compressor fitted with rotary compressor, copper condensor and first charge refrigent r410a / eco friendly green gas only, all complete including all electrical connections to the electrical power supply system of the building, includingbut not limited to supply of all electrical plugs, etc., as necessary, lengthening of all electrical wires of ac units ( both indoor and outdoor ) , drain pipe andincluding suitable voltage stabilisers, etc. so as to place them in a concealed manner in the desired position. the copper pipes and electrical cables shall be concealed in approved manner and neatly run in straight lines in a workman like manner with proper supports. complete supply and installation of split2 tr star rating 3 star , refrigerant piping copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 25 mm od, wall thickness >= 1.2 mm ( insulation 19 mm thick ) , refrigerant piping 1 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 19.1 mm od, wall thickness >= 1.0 mm ( insulation 13 mm thick ) , refrigerant piping 2 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 15.9 mm od, wall thickness >= 0.8 mm ( insulation 13 mm thick ) , refrigerant piping 3 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 9.5 mm od, wall thickness >= 0.8 mm ( insulation 13 mm thick ) , drain piping providing and fixing of cpvc 6 kg / cm2 drainpiping complete with fittings, supports, 6 mm thick closed cell elastomeric insulation as per specifications and drawings. 20 mm , drain piping 1 providing and fixing of cpvc 6 kg / cm2 drainpiping complete with fittings, supports, 6 mm thick closed cell elastomeric insulation as per specifications and drawings. 32 mm , main oxygen manifold supply, installation, testing and commissioning of following gas manifold system ( excluding cylinders ) . the manifold is configured for designed numbers of cylinders and is suitable to withstand a pressure of 145 kg / cm2, along withhigh pressure copper annealed tail pipes with end brass adapter suitable for cylinders and manifold. top frame comprising of high pressure copper pipes of size 1 / 2” nb x 15swg with high pressure brass fittings made of high tensile brass and connections through nonreturn valves, the design of middle and bottomframes is provided to fit both round and flat bottom cylinders safely. the manifold is tested ( hydraulically ) at 3500 psig. ( it should be ce and iso 13485 certified ) mani fold oxygen manifold 6 + 6 cylinder banks complete with nrv, middle frame, bottom frame with ce marked, , emergency manifold emergency oxygen manifold 01 + 01 cylinder emergency manifold with complete regulator, nrv, middle frame & bottom frame, , control panelfor oxygen fully automatic three port control panel for oxygen supply, installation, testing and commissioning of automatic manifold control panel would provide a duty or standby gas supply from two cylinder banks with automaticchangeover the manifold indicates local status and has a remote indicator facility. automaticmanifold control panel would be designed to supply the mgps with a constant pressure supply via a control panel form two equal banks of cylinders and the changeover from the ‘duty’ to the ‘standby’ bank of cylinders would beautomatic. automatic changeover from the duty to the standby bank would occur at a cylinder pressure that will ensure the maximum usage of the contents of the duty bank. the changeover unit would be provided with monitoring todetect and display: duty bank operating, duty bank empty, standby bank operating, and standby bank below 10 % when the duty bank is empty, reserve bank low, pipeline pressure fault. there would be facility to connect liquidoxygen supply ( i.e. three port control panel ) ( it should be ce and iso 13485 certified ) fully automatic three port control panel for oxygen , emergency manifold line regulator emergency manifold line regulator supply, installation, testing and commissioning of emergency manifold line regulator i n p u t p r e s s u r e 1 5 0 k g / c m 2 working pressure 4 kg / cm2 it should be ce and iso 13485 certified.oxygen input pressure 150 kg / cm2 working pressure 4 kg / cm2capacity : 1500 lpm , cylinderconnectingpipe ( pig tail ) supply, installation, testing and commissioning of cylinder connecting pipe ( pig tail ) made up of flexible ss hose with safety cord 5 / 8 inch bsp gland nut and one side 1 / 2 inch bsp internal threads having one meter length. ( oxygen 24 , n2o 10, co2 4 ) , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , medical air ( 4 bar ) outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve, supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified.42mm , isolation valve 2 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 28mm , isolation valve 3 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 22mm , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness , pipeline 4 medical grade copper pipeline ( in mtrs. ) as per en 13348, 28 mm ( od ) x 0.9 mm thickness , pipeline 5 medical grade copper pipeline ( in mtrs. ) as per en 13348, 42 mm ( od ) x 1.2 mm thickness , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 2268 mm x ( w ) 922 mm x ( h ) 610 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , paediatric bed with mattress paediatric bed of overall sizes in mm: 1500 ( l ) x 850 ( w ) x 1210 ( h ) flat single section bed with grille frame on 4 sides.suitable for children up to 12 years.drop down grill frame on both sides for protection of the patient.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral white , bed side locker type i over all dimension :402mmlx422mm wx840mm ht .locker should have one cabinet and one drawer unit .both provided with cam lock .there should be gap between drawer and unit to keep general items for frequesnt use castors are provided for easy handling .drawer made up of crca sheet 1 mm thick and has ball slide for easy operation .top ss 304 sheet 0.8 mm thick castors 50 mmdia , hamdle abs ..powder coating of epoxy polyester , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , strecher on trolley type i 2005mm ( l ) x666mm ( w ) x827mm ( h ) .the trolley should be made of 31.75 and 25.4 mm dia 1.6 mm thick erw tube.holder for stretcher should be made up of mild steel.castor should be of 200 mm dia , diagonal locking castor.stretcher should be made up oferw tubeof dia 25.4 mm and thickness 1.6 mm.top sheet should be made of crca sheetof thickness 1.2 mm with contour shape to accommodate patient.iv pole holder should be made ofms .maximum safe work load should be 135 kg.to ensure qood quality welding co2 argonprocess should be adhered to.all metal componentsshould be pre treated with zinc phosphating in 9 tank porcess and then powder coated with anti microbialepoxy polyster powder coating.goods should be supplied in knocked down construction to reduce carbon emission. performance test :proof loading test , cycle tests , impact test, salt spray test, castor break test, the manufacturer should compilant with iso 9001, 14001, 13485, ohsas 1800 and ce certification. , doctor desk type x s / f / f executive table main desk should be of dimesion : 1350w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. side panels : ( black ) made form 18mm thick plt with pvc lipping.modesty panel : made form 18mm thick plt with pvc lipping. bigger upper panel in black and smaller lower panel in white cedar. made from 18mm thick plt with pvc lipping. mobile pedestal : one box and one filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , chair type iii s / f / f executive chair1 ) seat / back assembly: the seat and back are made up of 1.2 cm. thick hot pressed plywood, upholstered withfabric upholstery covers and moulded polyurethane foam. the back foam is designed with contoured lumbar support for extra comfort. the seat has extra thick foam on front edge to give comfort to popliteal area.high back size : 47.5 cm ( w ) x 69.5 cm ( h ) seat size : 47.0 cm. ( w ) x 48.0 cm. ( d ) 2 ) polyurethane foam: the polyurethane foam is moulded with density = 45 + / 2 kg / m 3and hardness = 20 + / 2at 25% compression. 3 ) armrests: the one piece armrests are injection moulded from black co polymer polypropylene. 4 ) center tilt synchro mechanism : the mechanism is designed with the following features:• 360 revolving type. • upright position locking. • tilt tension adjustment.• seat / back tilting ratio of 1:3 ( 60 seat tilt / 180 back tilt ) . 5 ) pneumatic height adjustment : the pneumatic height adjustment has anadjustment stroke of 12.0 cm. 6 ) telescopic bellow assembly : the bellow is 3 piece telescopic type and injection moulded in black polypropylene. 7 ) pedestal assembly , staff / visitor chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck .3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement.mx load bearing capacity should be 10 kg. , hospital curtain tracks & i.v. tree system supply installation testing & commissioning of cubical tracks system made of powder coated aluminium alloy, stain free polyster fabric , water repellent curtains , smooth movement , non sticking runnner with stainless steel hooks made from mirror finish stainless steel , adjustable height with all accessories. total quantity : 1...

Health And Family Welfare Department - Bihar

30243928 bids are invited for pile20.2.3 boring, providing and installing bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement butincluding the cost of boring, with bentonite solution andtemporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavatedearth with all lifts and leads ( length of pile for payment shall be measured upto bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc4.1.5 providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , reinforcement steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 111.41a.3.1 providing and laying vitrified tiles in floor in different sizes { thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 ( 1 cement: 4 coarse sand ) jointing with grey cement slurry @3.3 kg / sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only.laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt / antiskid finish of size size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge : flamed finish granite stone slab jet black, cherry red, elite brown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel itemgalvanised @80gsm ) 50 mm long 8mm outer diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’. the system should rest on periphery walls / partitions with the help of gi perimeter wall angle of size24x24x3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall s.s. screws. the exposed bottom portion of all t sections used in false ceiling support system shall be pre painted with polyester baked paint, for all heights. the work shall be carried out as per specifications, drawings and as per directions of the engineer in charge. with 16 mm thick beveled tegular mineral fibre antimicrobial false ceiling tile confirming to iso 5 ( class 100 ) specifications , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975.the frames shall be fixed to rcc slab or tie beam over neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to aisi 304 and 316 at 500mm c / c with minimum embedment of 100mm in rcc ( rcc to be paid separately ) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. the item also includes the submission of stability reports dulyexamined and issued by any nit / iit. the rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with dry distemper of approved brand and manufacture ( two or more coats ) and of required shade on new work , over and including priming coat of whiting to give an even shade. , ex. paint finishing walls with acrylic smooth exterior paint of required shade : new work ( two or more coat applied @ 1.67 ltr / 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm ) , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing: rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white p.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings and floors wherever required :white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm. clear depth and 250mm apron including cost of e / w. involved with 75mm cement concrete ( 1:4:8 ) over one brick designation 100 a flat soling in proper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 4.5 kg. , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 4 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 3 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 4 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 5 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 6 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 7 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 8 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 9 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 10 bell push , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , earthing 1 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 2 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 3 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 1900 mm x ( w ) 900 mm x ( h ) 600 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , desk main desk should be of dimesion : 1200w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , staff chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck . 3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement. mx load bearing capacity should be 10 kg. , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness total quantity : 1...

Department Of Health And Family Welfare - Bihar

30232919 bids are invited for pile20.2.3 boring, providing and installing bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement butincluding the cost of boring, with bentonite solution andtemporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavatedearth with all lifts and leads ( length of pile for payment shall be measured upto bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc4.1.5 providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , reinforcement steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 111.41a.3.1 providing and laying vitrified tiles in floor in different sizes { thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 ( 1 cement: 4 coarse sand ) jointing with grey cement slurry @3.3 kg / sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only.laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt / antiskid finish of size size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge : flamed finish granite stone slab jet black, cherry red, elite brown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel itemgalvanised @80gsm ) 50 mm long 8mm outer diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’. the system should rest on periphery walls / partitions with the help of gi perimeter wall angle of size24x24x3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall s.s. screws. the exposed bottom portion of all t sections used in false ceiling support system shall be pre painted with polyester baked paint, for all heights. the work shall be carried out as per specifications, drawings and as per directions of the engineer in charge. with 16 mm thick beveled tegular mineral fibre antimicrobial false ceiling tile confirming to iso 5 ( class 100 ) specifications , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975.the frames shall be fixed to rcc slab or tie beam over neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to aisi 304 and 316 at 500mm c / c with minimum embedment of 100mm in rcc ( rcc to be paid separately ) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. the item also includes the submission of stability reports dulyexamined and issued by any nit / iit. the rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with dry distemper of approved brand and manufacture ( two or more coats ) and of required shade on new work , over and including priming coat of whiting to give an even shade. , ex. paint finishing walls with acrylic smooth exterior paint of required shade : new work ( two or more coat applied @ 1.67 ltr / 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm ) , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing: rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white p.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings and floors wherever required :white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm. clear depth and 250mm apron including cost of e / w. involved with 75mm cement concrete ( 1:4:8 ) over one brick designation 100 a flat soling in proper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 4.5 kg. , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 4 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 3 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 4 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 5 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 6 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 7 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 8 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 9 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 10 bell push , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , earthing 1 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 2 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 3 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 1900 mm x ( w ) 900 mm x ( h ) 600 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , desk main desk should be of dimesion : 1200w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , staff chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck . 3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement. mx load bearing capacity should be 10 kg. , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness total quantity : 1...

Health And Family Welfare Department - Bihar

30225212 bids are invited for pile20.2.3 boring, providing and installing bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement butincluding the cost of boring, with bentonite solution andtemporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavatedearth with all lifts and leads ( length of pile for payment shall be measured upto bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc4.1.5 providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , reinforcement steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 111.41a.3.1 providing and laying vitrified tiles in floor in different sizes { thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 ( 1 cement: 4 coarse sand ) jointing with grey cement slurry @3.3 kg / sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only.laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt / antiskid finish of size size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge : flamed finish granite stone slab jet black, cherry red, elite brown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel itemgalvanised @80gsm ) 50 mm long 8mm outer diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’. the system should rest on periphery walls / partitions with the help of gi perimeter wall angle of size24x24x3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall s.s. screws. the exposed bottom portion of all t sections used in false ceiling support system shall be pre painted with polyester baked paint, for all heights. the work shall be carried out as per specifications, drawings and as per directions of the engineer in charge. with 16 mm thick beveled tegular mineral fibre antimicrobial false ceiling tile confirming to iso 5 ( class 100 ) specifications , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975.the frames shall be fixed to rcc slab or tie beam over neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to aisi 304 and 316 at 500mm c / c with minimum embedment of 100mm in rcc ( rcc to be paid separately ) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. the item also includes the submission of stability reports dulyexamined and issued by any nit / iit. the rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with dry distemper of approved brand and manufacture ( two or more coats ) and of required shade on new work , over and including priming coat of whiting to give an even shade. , ex. paint finishing walls with acrylic smooth exterior paint of required shade : new work ( two or more coat applied @ 1.67 ltr / 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm ) , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing: rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white p.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings and floors wherever required :white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm. clear depth and 250mm apron including cost of e / w. involved with 75mm cement concrete ( 1:4:8 ) over one brick designation 100 a flat soling in proper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 4.5 kg. , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 4 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 3 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 4 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 5 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 6 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 7 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 8 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 9 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 10 bell push , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , earthing 1 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 2 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 3 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 1900 mm x ( w ) 900 mm x ( h ) 600 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , desk main desk should be of dimesion : 1200w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , staff chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck . 3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement. mx load bearing capacity should be 10 kg. , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness total quantity : 1...

Bihar Medical Service And Infrastructure Corporation Ltd - Bihar

30223853 bids are invited for pile20.2.3 boring, providing and installing bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement butincluding the cost of boring, with bentonite solution andtemporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavatedearth with all lifts and leads ( length of pile for payment shall be measured upto bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc4.1.5 providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , reinforcement steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 111.41a.3.1 providing and laying vitrified tiles in floor in different sizes { thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 ( 1 cement: 4 coarse sand ) jointing with grey cement slurry @3.3 kg / sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only.laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt / antiskid finish of size size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge : flamed finish granite stone slab jet black, cherry red, elite brown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel itemgalvanised @80gsm ) 50 mm long 8mm outer diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’. the system should rest on periphery walls / partitions with the help of gi perimeter wall angle of size24x24x3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall s.s. screws. the exposed bottom portion of all t sections used in false ceiling support system shall be pre painted with polyester baked paint, for all heights. the work shall be carried out as per specifications, drawings and as per directions of the engineer in charge. with 16 mm thick beveled tegular mineral fibre antimicrobial false ceiling tile confirming to iso 5 ( class 100 ) specifications , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975.the frames shall be fixed to rcc slab or tie beam over neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to aisi 304 and 316 at 500mm c / c with minimum embedment of 100mm in rcc ( rcc to be paid separately ) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. the item also includes the submission of stability reports dulyexamined and issued by any nit / iit. the rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with dry distemper of approved brand and manufacture ( two or more coats ) and of required shade on new work , over and including priming coat of whiting to give an even shade. , ex. paint finishing walls with acrylic smooth exterior paint of required shade : new work ( two or more coat applied @ 1.67 ltr / 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm ) , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing: rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white p.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings and floors wherever required :white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm. clear depth and 250mm apron including cost of e / w. involved with 75mm cement concrete ( 1:4:8 ) over one brick designation 100 a flat soling in proper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 4.5 kg. , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 4 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 3 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 4 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 5 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 6 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 7 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 8 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 9 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 10 bell push , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , earthing 1 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 2 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 3 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 1900 mm x ( w ) 900 mm x ( h ) 600 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , desk main desk should be of dimesion : 1200w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , staff chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck . 3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement. mx load bearing capacity should be 10 kg. , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness total quantity : 1...

Health And Family Welfare Department - Bihar

30223082 bids are invited for pile20.2.3 boring, providing and installing bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement butincluding the cost of boring, with bentonite solution andtemporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavatedearth with all lifts and leads ( length of pile for payment shall be measured upto bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc4.1.5 providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , reinforcement steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 111.41a.3.1 providing and laying vitrified tiles in floor in different sizes { thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 ( 1 cement: 4 coarse sand ) jointing with grey cement slurry @3.3 kg / sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only.laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt / antiskid finish of size size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge : flamed finish granite stone slab jet black, cherry red, elite brown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel itemgalvanised @80gsm ) 50 mm long 8mm outer diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’. the system should rest on periphery walls / partitions with the help of gi perimeter wall angle of size24x24x3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall s.s. screws. the exposed bottom portion of all t sections used in false ceiling support system shall be pre painted with polyester baked paint, for all heights. the work shall be carried out as per specifications, drawings and as per directions of the engineer in charge. with 16 mm thick beveled tegular mineral fibre antimicrobial false ceiling tile confirming to iso 5 ( class 100 ) specifications , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975.the frames shall be fixed to rcc slab or tie beam over neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to aisi 304 and 316 at 500mm c / c with minimum embedment of 100mm in rcc ( rcc to be paid separately ) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. the item also includes the submission of stability reports dulyexamined and issued by any nit / iit. the rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with dry distemper of approved brand and manufacture ( two or more coats ) and of required shade on new work , over and including priming coat of whiting to give an even shade. , ex. paint finishing walls with acrylic smooth exterior paint of required shade : new work ( two or more coat applied @ 1.67 ltr / 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm ) , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing: rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white p.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings and floors wherever required :white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm. clear depth and 250mm apron including cost of e / w. involved with 75mm cement concrete ( 1:4:8 ) over one brick designation 100 a flat soling in proper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 4.5 kg. , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 4 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 3 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 4 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 5 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 6 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 7 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 8 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 9 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 10 bell push , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , earthing 1 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 2 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 3 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 1900 mm x ( w ) 900 mm x ( h ) 600 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , desk main desk should be of dimesion : 1200w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , staff chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck . 3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement. mx load bearing capacity should be 10 kg. , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness total quantity : 1...

Health And Family Welfare Department - Bihar

30222705 bids are invited for pile20.2.3 boring, providing and installing bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement butincluding the cost of boring, with bentonite solution andtemporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavatedearth with all lifts and leads ( length of pile for payment shall be measured upto bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc4.1.5 providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , reinforcement steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 111.41a.3.1 providing and laying vitrified tiles in floor in different sizes { thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 ( 1 cement: 4 coarse sand ) jointing with grey cement slurry @3.3 kg / sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only.laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt / antiskid finish of size size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge : flamed finish granite stone slab jet black, cherry red, elite brown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel itemgalvanised @80gsm ) 50 mm long 8mm outer diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’. the system should rest on periphery walls / partitions with the help of gi perimeter wall angle of size24x24x3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall s.s. screws. the exposed bottom portion of all t sections used in false ceiling support system shall be pre painted with polyester baked paint, for all heights. the work shall be carried out as per specifications, drawings and as per directions of the engineer in charge. with 16 mm thick beveled tegular mineral fibre antimicrobial false ceiling tile confirming to iso 5 ( class 100 ) specifications , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975.the frames shall be fixed to rcc slab or tie beam over neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to aisi 304 and 316 at 500mm c / c with minimum embedment of 100mm in rcc ( rcc to be paid separately ) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. the item also includes the submission of stability reports dulyexamined and issued by any nit / iit. the rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with dry distemper of approved brand and manufacture ( two or more coats ) and of required shade on new work , over and including priming coat of whiting to give an even shade. , ex. paint finishing walls with acrylic smooth exterior paint of required shade : new work ( two or more coat applied @ 1.67 ltr / 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm ) , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing: rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white p.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings and floors wherever required :white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm. clear depth and 250mm apron including cost of e / w. involved with 75mm cement concrete ( 1:4:8 ) over one brick designation 100 a flat soling in proper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 4.5 kg. , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 4 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 3 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 4 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 5 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 6 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 7 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 8 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 9 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 10 bell push , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , earthing 1 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 2 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 3 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 1900 mm x ( w ) 900 mm x ( h ) 600 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , desk main desk should be of dimesion : 1200w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , staff chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck . 3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement. mx load bearing capacity should be 10 kg. , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness total quantity : 1...

Health And Family Welfare Department - Bihar

30221807 bids are invited for pile20.2.3 boring, providing and installing bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement butincluding the cost of boring, with bentonite solution andtemporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavatedearth with all lifts and leads ( length of pile for payment shall be measured upto bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc4.1.5 providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , reinforcement steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 111.41a.3.1 providing and laying vitrified tiles in floor in different sizes { thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 ( 1 cement: 4 coarse sand ) jointing with grey cement slurry @3.3 kg / sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only.laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt / antiskid finish of size size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge : flamed finish granite stone slab jet black, cherry red, elite brown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel itemgalvanised @80gsm ) 50 mm long 8mm outer diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’. the system should rest on periphery walls / partitions with the help of gi perimeter wall angle of size24x24x3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall s.s. screws. the exposed bottom portion of all t sections used in false ceiling support system shall be pre painted with polyester baked paint, for all heights. the work shall be carried out as per specifications, drawings and as per directions of the engineer in charge. with 16 mm thick beveled tegular mineral fibre antimicrobial false ceiling tile confirming to iso 5 ( class 100 ) specifications , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975.the frames shall be fixed to rcc slab or tie beam over neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to aisi 304 and 316 at 500mm c / c with minimum embedment of 100mm in rcc ( rcc to be paid separately ) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. the item also includes the submission of stability reports dulyexamined and issued by any nit / iit. the rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with dry distemper of approved brand and manufacture ( two or more coats ) and of required shade on new work , over and including priming coat of whiting to give an even shade. , ex. paint finishing walls with acrylic smooth exterior paint of required shade : new work ( two or more coat applied @ 1.67 ltr / 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm ) , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing: rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white p.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings and floors wherever required :white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm. clear depth and 250mm apron including cost of e / w. involved with 75mm cement concrete ( 1:4:8 ) over one brick designation 100 a flat soling in proper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 4.5 kg. , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 4 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 3 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 4 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 5 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 6 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 7 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 8 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 9 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 10 bell push , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , earthing 1 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 2 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 3 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 1900 mm x ( w ) 900 mm x ( h ) 600 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , desk main desk should be of dimesion : 1200w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , staff chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck . 3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement. mx load bearing capacity should be 10 kg. , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness total quantity : 1...

Health And Family Welfare Department - Bihar

30221801 bids are invited for pile20.2.3 boring, providing and installing bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement butincluding the cost of boring, with bentonite solution andtemporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavatedearth with all lifts and leads ( length of pile for payment shall be measured upto bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc4.1.5 providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , reinforcement steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 111.41a.3.1 providing and laying vitrified tiles in floor in different sizes { thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 ( 1 cement: 4 coarse sand ) jointing with grey cement slurry @3.3 kg / sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only.laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt / antiskid finish of size size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge : flamed finish granite stone slab jet black, cherry red, elite brown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel itemgalvanised @80gsm ) 50 mm long 8mm outer diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’. the system should rest on periphery walls / partitions with the help of gi perimeter wall angle of size24x24x3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall s.s. screws. the exposed bottom portion of all t sections used in false ceiling support system shall be pre painted with polyester baked paint, for all heights. the work shall be carried out as per specifications, drawings and as per directions of the engineer in charge. with 16 mm thick beveled tegular mineral fibre antimicrobial false ceiling tile confirming to iso 5 ( class 100 ) specifications , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975.the frames shall be fixed to rcc slab or tie beam over neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to aisi 304 and 316 at 500mm c / c with minimum embedment of 100mm in rcc ( rcc to be paid separately ) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. the item also includes the submission of stability reports dulyexamined and issued by any nit / iit. the rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with dry distemper of approved brand and manufacture ( two or more coats ) and of required shade on new work , over and including priming coat of whiting to give an even shade. , ex. paint finishing walls with acrylic smooth exterior paint of required shade : new work ( two or more coat applied @ 1.67 ltr / 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm ) , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing: rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white p.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings and floors wherever required :white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm. clear depth and 250mm apron including cost of e / w. involved with 75mm cement concrete ( 1:4:8 ) over one brick designation 100 a flat soling in proper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 4.5 kg. , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 4 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 3 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 4 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 5 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 6 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 7 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 8 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 9 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 10 bell push , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , earthing 1 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 2 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 3 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 1900 mm x ( w ) 900 mm x ( h ) 600 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , desk main desk should be of dimesion : 1200w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , staff chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck . 3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement. mx load bearing capacity should be 10 kg. , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness total quantity : 1...

Health And Family Welfare Department - Bihar

30221787 bids are invited for pile20.2.3 boring, providing and installing bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement butincluding the cost of boring, with bentonite solution andtemporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavatedearth with all lifts and leads ( length of pile for payment shall be measured upto bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc4.1.5 providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , reinforcement steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 111.41a.3.1 providing and laying vitrified tiles in floor in different sizes { thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 ( 1 cement: 4 coarse sand ) jointing with grey cement slurry @3.3 kg / sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only.laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt / antiskid finish of size size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge : flamed finish granite stone slab jet black, cherry red, elite brown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel itemgalvanised @80gsm ) 50 mm long 8mm outer diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’. the system should rest on periphery walls / partitions with the help of gi perimeter wall angle of size24x24x3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall s.s. screws. the exposed bottom portion of all t sections used in false ceiling support system shall be pre painted with polyester baked paint, for all heights. the work shall be carried out as per specifications, drawings and as per directions of the engineer in charge. with 16 mm thick beveled tegular mineral fibre antimicrobial false ceiling tile confirming to iso 5 ( class 100 ) specifications , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975.the frames shall be fixed to rcc slab or tie beam over neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to aisi 304 and 316 at 500mm c / c with minimum embedment of 100mm in rcc ( rcc to be paid separately ) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. the item also includes the submission of stability reports dulyexamined and issued by any nit / iit. the rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with dry distemper of approved brand and manufacture ( two or more coats ) and of required shade on new work , over and including priming coat of whiting to give an even shade. , ex. paint finishing walls with acrylic smooth exterior paint of required shade : new work ( two or more coat applied @ 1.67 ltr / 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm ) , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing: rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white p.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings and floors wherever required :white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm. clear depth and 250mm apron including cost of e / w. involved with 75mm cement concrete ( 1:4:8 ) over one brick designation 100 a flat soling in proper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 4.5 kg. , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 4 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 3 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 4 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 5 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 6 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 7 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 8 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 9 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 10 bell push , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , earthing 1 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 2 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 3 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 1900 mm x ( w ) 900 mm x ( h ) 600 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , desk main desk should be of dimesion : 1200w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , staff chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck . 3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement. mx load bearing capacity should be 10 kg. , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness total quantity : 1...

Health And Family Welfare Department - Bihar

30221454 bids are invited for pile20.2.3 boring, providing and installing bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement butincluding the cost of boring, with bentonite solution andtemporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavatedearth with all lifts and leads ( length of pile for payment shall be measured upto bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc4.1.5 providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , reinforcement steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 111.41a.3.1 providing and laying vitrified tiles in floor in different sizes { thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 ( 1 cement: 4 coarse sand ) jointing with grey cement slurry @3.3 kg / sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only.laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt / antiskid finish of size size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge : flamed finish granite stone slab jet black, cherry red, elite brown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel itemgalvanised @80gsm ) 50 mm long 8mm outer diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’. the system should rest on periphery walls / partitions with the help of gi perimeter wall angle of size24x24x3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall s.s. screws. the exposed bottom portion of all t sections used in false ceiling support system shall be pre painted with polyester baked paint, for all heights. the work shall be carried out as per specifications, drawings and as per directions of the engineer in charge. with 16 mm thick beveled tegular mineral fibre antimicrobial false ceiling tile confirming to iso 5 ( class 100 ) specifications , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975.the frames shall be fixed to rcc slab or tie beam over neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to aisi 304 and 316 at 500mm c / c with minimum embedment of 100mm in rcc ( rcc to be paid separately ) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. the item also includes the submission of stability reports dulyexamined and issued by any nit / iit. the rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with dry distemper of approved brand and manufacture ( two or more coats ) and of required shade on new work , over and including priming coat of whiting to give an even shade. , ex. paint finishing walls with acrylic smooth exterior paint of required shade : new work ( two or more coat applied @ 1.67 ltr / 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm ) , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing: rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white p.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings and floors wherever required :white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm. clear depth and 250mm apron including cost of e / w. involved with 75mm cement concrete ( 1:4:8 ) over one brick designation 100 a flat soling in proper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 4.5 kg. , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 4 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 3 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 4 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 5 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 6 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 7 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 8 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 9 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 10 bell push , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , earthing 1 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 2 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 3 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 1900 mm x ( w ) 900 mm x ( h ) 600 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , desk main desk should be of dimesion : 1200w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , staff chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck . 3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement. mx load bearing capacity should be 10 kg. , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness total quantity : 1...

Health And Family Welfare Department - Bihar

30220852 bids are invited for pile20.2.3 boring, providing and installing bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement butincluding the cost of boring, with bentonite solution andtemporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavatedearth with all lifts and leads ( length of pile for payment shall be measured upto bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc4.1.5 providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , reinforcement steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 111.41a.3.1 providing and laying vitrified tiles in floor in different sizes { thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 ( 1 cement: 4 coarse sand ) jointing with grey cement slurry @3.3 kg / sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only.laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt / antiskid finish of size size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge : flamed finish granite stone slab jet black, cherry red, elite brown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel itemgalvanised @80gsm ) 50 mm long 8mm outer diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’. the system should rest on periphery walls / partitions with the help of gi perimeter wall angle of size24x24x3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall s.s. screws. the exposed bottom portion of all t sections used in false ceiling support system shall be pre painted with polyester baked paint, for all heights. the work shall be carried out as per specifications, drawings and as per directions of the engineer in charge. with 16 mm thick beveled tegular mineral fibre antimicrobial false ceiling tile confirming to iso 5 ( class 100 ) specifications , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975.the frames shall be fixed to rcc slab or tie beam over neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to aisi 304 and 316 at 500mm c / c with minimum embedment of 100mm in rcc ( rcc to be paid separately ) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. the item also includes the submission of stability reports dulyexamined and issued by any nit / iit. the rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with dry distemper of approved brand and manufacture ( two or more coats ) and of required shade on new work , over and including priming coat of whiting to give an even shade. , ex. paint finishing walls with acrylic smooth exterior paint of required shade : new work ( two or more coat applied @ 1.67 ltr / 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm ) , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing: rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white p.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings and floors wherever required :white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm. clear depth and 250mm apron including cost of e / w. involved with 75mm cement concrete ( 1:4:8 ) over one brick designation 100 a flat soling in proper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 4.5 kg. , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 4 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 3 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 4 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 5 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 6 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 7 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 8 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 9 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 10 bell push , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , earthing 1 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 2 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 3 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 1900 mm x ( w ) 900 mm x ( h ) 600 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , desk main desk should be of dimesion : 1200w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , staff chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck . 3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement. mx load bearing capacity should be 10 kg. , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness total quantity : 1...

Health And Family Welfare Department - Bihar

30220634 bids are invited for pile20.2.3 boring, providing and installing bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement butincluding the cost of boring, with bentonite solution andtemporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavatedearth with all lifts and leads ( length of pile for payment shall be measured upto bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc4.1.5 providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , reinforcement steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 111.41a.3.1 providing and laying vitrified tiles in floor in different sizes { thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 ( 1 cement: 4 coarse sand ) jointing with grey cement slurry @3.3 kg / sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only.laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt / antiskid finish of size size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge : flamed finish granite stone slab jet black, cherry red, elite brown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel itemgalvanised @80gsm ) 50 mm long 8mm outer diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’. the system should rest on periphery walls / partitions with the help of gi perimeter wall angle of size24x24x3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall s.s. screws. the exposed bottom portion of all t sections used in false ceiling support system shall be pre painted with polyester baked paint, for all heights. the work shall be carried out as per specifications, drawings and as per directions of the engineer in charge. with 16 mm thick beveled tegular mineral fibre antimicrobial false ceiling tile confirming to iso 5 ( class 100 ) specifications , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975.the frames shall be fixed to rcc slab or tie beam over neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to aisi 304 and 316 at 500mm c / c with minimum embedment of 100mm in rcc ( rcc to be paid separately ) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. the item also includes the submission of stability reports dulyexamined and issued by any nit / iit. the rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with dry distemper of approved brand and manufacture ( two or more coats ) and of required shade on new work , over and including priming coat of whiting to give an even shade. , ex. paint finishing walls with acrylic smooth exterior paint of required shade : new work ( two or more coat applied @ 1.67 ltr / 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm ) , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing: rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white p.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings and floors wherever required :white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm. clear depth and 250mm apron including cost of e / w. involved with 75mm cement concrete ( 1:4:8 ) over one brick designation 100 a flat soling in proper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 4.5 kg. , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 4 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 3 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 4 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 5 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 6 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 7 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 8 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 9 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 10 bell push , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , earthing 1 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 2 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 3 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 1900 mm x ( w ) 900 mm x ( h ) 600 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , desk main desk should be of dimesion : 1200w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , staff chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck . 3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement. mx load bearing capacity should be 10 kg. , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness total quantity : 1...

Health And Family Welfare Department - Bihar

30220560 bids are invited for pile20.2.3 boring, providing and installing bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement butincluding the cost of boring, with bentonite solution andtemporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavatedearth with all lifts and leads ( length of pile for payment shall be measured upto bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc4.1.5 providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , reinforcement steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 111.41a.3.1 providing and laying vitrified tiles in floor in different sizes { thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 ( 1 cement: 4 coarse sand ) jointing with grey cement slurry @3.3 kg / sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only.laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt / antiskid finish of size size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge : flamed finish granite stone slab jet black, cherry red, elite brown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel itemgalvanised @80gsm ) 50 mm long 8mm outer diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’. the system should rest on periphery walls / partitions with the help of gi perimeter wall angle of size24x24x3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall s.s. screws. the exposed bottom portion of all t sections used in false ceiling support system shall be pre painted with polyester baked paint, for all heights. the work shall be carried out as per specifications, drawings and as per directions of the engineer in charge. with 16 mm thick beveled tegular mineral fibre antimicrobial false ceiling tile confirming to iso 5 ( class 100 ) specifications , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975.the frames shall be fixed to rcc slab or tie beam over neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to aisi 304 and 316 at 500mm c / c with minimum embedment of 100mm in rcc ( rcc to be paid separately ) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. the item also includes the submission of stability reports dulyexamined and issued by any nit / iit. the rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with dry distemper of approved brand and manufacture ( two or more coats ) and of required shade on new work , over and including priming coat of whiting to give an even shade. , ex. paint finishing walls with acrylic smooth exterior paint of required shade : new work ( two or more coat applied @ 1.67 ltr / 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm ) , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing: rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white p.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings and floors wherever required :white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm. clear depth and 250mm apron including cost of e / w. involved with 75mm cement concrete ( 1:4:8 ) over one brick designation 100 a flat soling in proper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 4.5 kg. , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 4 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 3 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 4 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 5 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 6 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 7 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 8 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 9 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 10 bell push , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , earthing 1 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 2 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 3 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 1900 mm x ( w ) 900 mm x ( h ) 600 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , desk main desk should be of dimesion : 1200w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , staff chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck . 3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement. mx load bearing capacity should be 10 kg. , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness total quantity : 1...

Health And Family Welfare Department - Bihar

30220478 bids are invited for pile20.2.3 boring, providing and installing bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement butincluding the cost of boring, with bentonite solution andtemporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavatedearth with all lifts and leads ( length of pile for payment shall be measured upto bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc4.1.5 providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , reinforcement steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 111.41a.3.1 providing and laying vitrified tiles in floor in different sizes { thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 ( 1 cement: 4 coarse sand ) jointing with grey cement slurry @3.3 kg / sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only.laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt / antiskid finish of size size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge : flamed finish granite stone slab jet black, cherry red, elite brown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel itemgalvanised @80gsm ) 50 mm long 8mm outer diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’. the system should rest on periphery walls / partitions with the help of gi perimeter wall angle of size24x24x3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall s.s. screws. the exposed bottom portion of all t sections used in false ceiling support system shall be pre painted with polyester baked paint, for all heights. the work shall be carried out as per specifications, drawings and as per directions of the engineer in charge. with 16 mm thick beveled tegular mineral fibre antimicrobial false ceiling tile confirming to iso 5 ( class 100 ) specifications , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975.the frames shall be fixed to rcc slab or tie beam over neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to aisi 304 and 316 at 500mm c / c with minimum embedment of 100mm in rcc ( rcc to be paid separately ) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. the item also includes the submission of stability reports dulyexamined and issued by any nit / iit. the rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with dry distemper of approved brand and manufacture ( two or more coats ) and of required shade on new work , over and including priming coat of whiting to give an even shade. , ex. paint finishing walls with acrylic smooth exterior paint of required shade : new work ( two or more coat applied @ 1.67 ltr / 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm ) , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing: rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white p.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings and floors wherever required :white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm. clear depth and 250mm apron including cost of e / w. involved with 75mm cement concrete ( 1:4:8 ) over one brick designation 100 a flat soling in proper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 4.5 kg. , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 4 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 3 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 4 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 5 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 6 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 7 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 8 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 9 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 10 bell push , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , earthing 1 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 2 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 3 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 1900 mm x ( w ) 900 mm x ( h ) 600 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , desk main desk should be of dimesion : 1200w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , staff chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck . 3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement. mx load bearing capacity should be 10 kg. , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness total quantity : 1...

Health And Family Welfare Department - Bihar

30220348 bids are invited for pile20.2.3 boring, providing and installing bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement butincluding the cost of boring, with bentonite solution andtemporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavatedearth with all lifts and leads ( length of pile for payment shall be measured upto bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc4.1.5 providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , reinforcement steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 111.41a.3.1 providing and laying vitrified tiles in floor in different sizes { thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 ( 1 cement: 4 coarse sand ) jointing with grey cement slurry @3.3 kg / sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only.laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt / antiskid finish of size size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge : flamed finish granite stone slab jet black, cherry red, elite brown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel itemgalvanised @80gsm ) 50 mm long 8mm outer diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’. the system should rest on periphery walls / partitions with the help of gi perimeter wall angle of size24x24x3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall s.s. screws. the exposed bottom portion of all t sections used in false ceiling support system shall be pre painted with polyester baked paint, for all heights. the work shall be carried out as per specifications, drawings and as per directions of the engineer in charge. with 16 mm thick beveled tegular mineral fibre antimicrobial false ceiling tile confirming to iso 5 ( class 100 ) specifications , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975.the frames shall be fixed to rcc slab or tie beam over neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to aisi 304 and 316 at 500mm c / c with minimum embedment of 100mm in rcc ( rcc to be paid separately ) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. the item also includes the submission of stability reports dulyexamined and issued by any nit / iit. the rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with dry distemper of approved brand and manufacture ( two or more coats ) and of required shade on new work , over and including priming coat of whiting to give an even shade. , ex. paint finishing walls with acrylic smooth exterior paint of required shade : new work ( two or more coat applied @ 1.67 ltr / 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm ) , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing: rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white p.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings and floors wherever required :white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm. clear depth and 250mm apron including cost of e / w. involved with 75mm cement concrete ( 1:4:8 ) over one brick designation 100 a flat soling in proper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 4.5 kg. , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 4 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 3 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 4 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 5 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 6 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 7 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 8 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 9 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 10 bell push , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , earthing 1 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 2 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 3 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 1900 mm x ( w ) 900 mm x ( h ) 600 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , desk main desk should be of dimesion : 1200w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , staff chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck . 3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement. mx load bearing capacity should be 10 kg. , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness total quantity : 1...

Health And Family Welfare Department - Bihar

30220314 bids are invited for pile20.2.3 boring, providing and installing bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement butincluding the cost of boring, with bentonite solution andtemporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavatedearth with all lifts and leads ( length of pile for payment shall be measured upto bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc4.1.5 providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , reinforcement steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 111.41a.3.1 providing and laying vitrified tiles in floor in different sizes { thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 ( 1 cement: 4 coarse sand ) jointing with grey cement slurry @3.3 kg / sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only.laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt / antiskid finish of size size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge : flamed finish granite stone slab jet black, cherry red, elite brown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel itemgalvanised @80gsm ) 50 mm long 8mm outer diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’. the system should rest on periphery walls / partitions with the help of gi perimeter wall angle of size24x24x3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall s.s. screws. the exposed bottom portion of all t sections used in false ceiling support system shall be pre painted with polyester baked paint, for all heights. the work shall be carried out as per specifications, drawings and as per directions of the engineer in charge. with 16 mm thick beveled tegular mineral fibre antimicrobial false ceiling tile confirming to iso 5 ( class 100 ) specifications , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975.the frames shall be fixed to rcc slab or tie beam over neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to aisi 304 and 316 at 500mm c / c with minimum embedment of 100mm in rcc ( rcc to be paid separately ) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. the item also includes the submission of stability reports dulyexamined and issued by any nit / iit. the rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with dry distemper of approved brand and manufacture ( two or more coats ) and of required shade on new work , over and including priming coat of whiting to give an even shade. , ex. paint finishing walls with acrylic smooth exterior paint of required shade : new work ( two or more coat applied @ 1.67 ltr / 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm ) , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing: rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white p.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings and floors wherever required :white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm. clear depth and 250mm apron including cost of e / w. involved with 75mm cement concrete ( 1:4:8 ) over one brick designation 100 a flat soling in proper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 4.5 kg. , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 4 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 3 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 4 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 5 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 6 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 7 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 8 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 9 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 10 bell push , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , earthing 1 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 2 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 3 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 1900 mm x ( w ) 900 mm x ( h ) 600 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , desk main desk should be of dimesion : 1200w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , staff chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck . 3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement. mx load bearing capacity should be 10 kg. , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness total quantity : 1...

Health And Family Welfare Department - Bihar

30219679 bids are invited for pile20.2.3 boring, providing and installing bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement butincluding the cost of boring, with bentonite solution andtemporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavatedearth with all lifts and leads ( length of pile for payment shall be measured upto bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc4.1.5 providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , reinforcement steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 111.41a.3.1 providing and laying vitrified tiles in floor in different sizes { thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 ( 1 cement: 4 coarse sand ) jointing with grey cement slurry @3.3 kg / sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only.laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt / antiskid finish of size size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge : flamed finish granite stone slab jet black, cherry red, elite brown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel itemgalvanised @80gsm ) 50 mm long 8mm outer diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’. the system should rest on periphery walls / partitions with the help of gi perimeter wall angle of size24x24x3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall s.s. screws. the exposed bottom portion of all t sections used in false ceiling support system shall be pre painted with polyester baked paint, for all heights. the work shall be carried out as per specifications, drawings and as per directions of the engineer in charge. with 16 mm thick beveled tegular mineral fibre antimicrobial false ceiling tile confirming to iso 5 ( class 100 ) specifications , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975.the frames shall be fixed to rcc slab or tie beam over neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to aisi 304 and 316 at 500mm c / c with minimum embedment of 100mm in rcc ( rcc to be paid separately ) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. the item also includes the submission of stability reports dulyexamined and issued by any nit / iit. the rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately ) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 ( high pressure steam cured ) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b ( high pressure steam cured ) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with dry distemper of approved brand and manufacture ( two or more coats ) and of required shade on new work , over and including priming coat of whiting to give an even shade. , ex. paint finishing walls with acrylic smooth exterior paint of required shade : new work ( two or more coat applied @ 1.67 ltr / 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm ) , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 4 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing: rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white p.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings and floors wherever required :white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 25 p / f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm. clear depth and 250mm apron including cost of e / w. involved with 75mm cement concrete ( 1:4:8 ) over one brick designation 100 a flat soling in proper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 4.5 kg. , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 4 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 3 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 4 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 5 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 6 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 7 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 8 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 9 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 10 bell push , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way , double door , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , earthing 1 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 2 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 3 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm / w .cri >80, color temperature 6500k, thd <20% and pf>0.95, ip20 . life class of 35, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95, ip20, ik03.life class of 50, 000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 1900 mm x ( w ) 900 mm x ( h ) 600 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm ) : 60hitlondensity ( gm / dcm3 ) : 23coir ( both side ) thicknessmm: 20density ( gm / dcm3 ) : 70, drc ( % ) : 22quilting combination / layers:pilled foam – quilting ( one side ) thicknessmm 14pilled foam density gm / dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine ( gsm ) : 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , desk main desk should be of dimesion : 1200w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , staff chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck . 3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement. mx load bearing capacity should be 10 kg. , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness total quantity : 1...

Health And Family Welfare Department - Bihar

30219593 bids are invited for pile20.2.3 boring, providing and installing bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement butincluding the cost of boring, with bentonite solution andtemporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. all complete, including removal of excavatedearth with all lifts and leads (length of pile for payment shall be measured upto bottom of pile cap).450mm dia piles (inclusive of carriage) , pcc4.1.5 providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 (1 cement : 3 coarse sand (zone iii) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) (inclusive of carriage) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland /portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. (inclusive of carriage) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 (1 cement : 4 coarse sand) (inclusive of carriage) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.(inclusive of carriage) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , reinforcement steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory/workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone iii) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber/ neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. (glazing, paneling and dash fasteners to be paid for separately) :powder coated aluminium (minimum thickness of powder coating 50 micron) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . (cost of aluminium snap beading shall be paid in basic item):with float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , solling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e/l, , tile 111.41a.3.1 providing and laying vitrified tiles in floor in different sizes {thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only.laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.glazed vitrified tiles matt/ antiskid finish of size size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge : flamed finish granite stone slab jet black, cherry red, elite brown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance (rh) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w/m k, fire performance as per (bs 476 pt 6 &7)in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel itemgalvanised @80gsm) 50 mm long 8mm outer diameter m 6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and l shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘t’. the system should rest on periphery walls /partitions with the help of gi perimeter wall angle of size24x24x3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall s.s. screws. the exposed bottom portion of all t sections used in false ceiling support system shall be pre painted with polyester baked paint, for all heights. the work shall be carried out as per specifications, drawings and as per directions of the engineer in charge. with 16 mm thick beveled tegular mineral fibre antimicrobial false ceiling tile confirming to iso 5 (class 100) specifications , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized (az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975.the frames shall be fixed to rcc slab or tie beam over neoprene rubber using self expanding carbon steel anchor bolt of dia as per approved drawings. design subject to minimum 12mm diameter and 121mm length conforming to aisi 304 and 316 at 500mm c/c with minimum embedment of 100mm in rcc (rcc to be paid separately) and located not more than 300mm from corners or termination of bottom tracks complete in all respects. the item also includes the submission of stability reports dulyexamined and issued by any nit/iit. the rate includes the concept design, detailed design, fabrication of sections, transportation, installation and all required fixing arrangement at site as described above. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c/c of approved make. a groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. the board shall be fixed in a staggered pattern. internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c/c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish.(cost of frame work to be paid for separately) outer face: outer face having 6mm thick fiber cement board fixed on 9mm thick fiber cement board, type a, as per is:14862:2000 (high pressure steam cured) inner face : 12.5 mm thick gypsum plaster board conforming to is 2095:2011 fixed on 8 mm thick fibre cement board confirming to is:14862:2000 of type b (high pressure steam cured) , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c/c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish.(cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by engineer in charge) 0.50 mm +/ 5% total coated thickness (tct) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal/vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm +/ 5% total coated thickness (tct) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling/ self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain (500 600mm). , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm +/ 5% total coated thickness (tct) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling/ self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness (tct), zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling/ self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings/ aprons. (upto 600 mm) , under deck insulation providing and fixing thermal insulation of ceiling (under deck insulation) with resin bonded rockwool conforming to is: 8183,density 48 kg/ m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg/m3,50 mm thick,wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with dry distemper of approved brand and manufacture (two or more coats ) and of required shade on new work , over and including priming coat of whiting to give an even shade. , ex. paint finishing walls with acrylic smooth exterior paint of required shade : new work (two or more coat applied @ 1.67 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 4 providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing: rectangular shape 453x357 mm , phe 5 providing and fixing toilet paper holder:c.p. brass , phe 6 providing and fixing water closet squatting pan (indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white p.v.c. flushing cistern, including flush pipe, with manually controlleddevice (handle lever) conforming to is : 7231, with all fittings and floors wherever required :white vitreous china orissa pattern w.c. pan of size 580x440 mm with integral type foot rests , phe 7 providing and fixing white vitreous china pedestal type water closet (european type w.c. pan) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 8 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 11 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 12 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 13 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a) 15 mm nominal bore.15 mm nominal bore , phe 14 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers , phe 19 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 20 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 22 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. (internal work) 40 mm dia, nominal bore , phe 23 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. (internal work)50 mm dia, nominal bore , phe 25 p/f m.s. cap 100 mm dia , phe 26 providing and fixing, upvcpipes 6 kg/cm2(is: 4985) including all fittings (plain or door) e.g. bends, junction, offsets, access pieces, jointing with rubber ring/solvent cement joints includingrequired suports,cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 27 providing and fixing, upvcpipes 6 kg/cm2(is: 4985) including all fittings (plain or door) e.g. bends, junction, offsets, access pieces, jointing with rubber ring/solvent cement joints includingrequired suports,cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 28 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. (i)single socketed pipes.110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings /accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 30 providing, fixing on wall face unplasticised pvc moulded fittings /accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 31 providing, fixing on wall face unplasticised pvc moulded fittings /accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 32 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4(1cement : 4 coarse sand) and making good the wall etc. complete.110 mm dia , phe 33 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 34 providing and fixing of gun metal gate valve with ci wheel of approved quality (screwed ends)25mm dia, nominal bore , phe 35 providing and fixing of gun metal gate valve with ci wheel of approved quality (screwed ends) 32 mm dia, nominal bore , phe 36 providing and fixing gun metal non return valve of approved quality (pn 1.6)40 nominal bore , phe 37 providing and fixing brass stop cock of approved quality15mm nominal bore , ex. phe 6 providing 250mm wide brick drain in cement mortar (1:6) with av. 150mm. clear depth and 250mm apron including cost of e/w. involved with 75mm cement concrete (1:4:8) over one brick designation 100 a flat soling in proper grade and slope at the base.the drain duly.plastered in cm. (1:3) with punning over exposed surface all complete as per buildingspecification and direction of e/l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil (hard or soft) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [hard/dense soil] pipes,cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class (light duty) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete. (for storm drainage)250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class (light duty) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete. (for storm drainage)300 mm dia rcc pipe , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement: 4 coarse sand) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with channel lid and rcc top slab 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement: 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 4.5 kg. , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface /recessed steel conduit, 2 way modular switch, modular plate,suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 4 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s/f, gi box along with modular base & cover plate 1 1 or 2 module (75mm x 75mm) , s/f, gi box along with modular base & cover plate 2 3 module (100mm x 75mm) , s/f, gi box along with modular base & cover plate 3 4 module (125mmx75mm) , s/f, gi box along with modular base & cover plate 4 6 module (200mm x 75mm) , s/f, gi box along with modular base & cover plate 5 12 module (200mmx150mm) , s/f modular switch/ socket on the existing modular plate 6 5/6 amps switch , s/f modular switch/ socket on the existing modular plate 7 15/16 amp switch , s/f modular switch/ socket on the existing modular plate 8 3 pin 5/6 amp socket outlet , s/f modular switch/ socket on the existing modular plate 9 6 pin 15/16 amp socket outlet , s/f modular switch/ socket on the existing modular plate 10 bell push , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 13 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/ rccb / isolator)8 way , double door , 40 a, rccb supplying and fixing following rating, double pole, (single phase and neutral), 240 v, residual current circuit breaker (rccb), having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a mcb supplying and fixing 40 a rating, 240/415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40 tp mcb , single pole mcb supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , earthing 1 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. , earthing 2 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. , earthing 3 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , fiting & fixtures 1 supply and installation of regular/standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18/22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall/ ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made (2ft) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm/w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply) with output short circuit protection, surge protection.can be fixed directly into the wall/ ceiling by means of mounting ss clips provided with the fixture. ip 20, lumen output of 950 lumens with system efficacy of > 105lm/w .cri >80, color temperature 6500k, thd <20% and pf>0.95,ip20 . life class of 35,000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source. cat ref havells :lumilinebs9wled840spcwh or approved equivalent. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong/grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm/w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver (smps based constant current supply) with output short circuit protection, surge protection & other reliability test. lumen output of 3450 lumens.cri >80, color temperature 5700k, thd <10% and pf >0.95,ip20,ik03.life class of 50,000 hrs @ l70, operating temperature: 10 to +45 deg.c; input supply voltage range:140 270 v, frequency :50 60 hz;internal surge protection:3 kv; protection including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required. : reverse polarity, open & short circuit. driver safety requirement standards :is 15885 2 13, test report to be submitted; photo biological safety norms: is 16108, test certificate to be submitted; certification: lm 79 for luminaire lm 80 for led source.cat ref havells :venusneohe2x2plr128wled857 or approved equivalent. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , hospital sheet patient bedtype iii with mattress overall sizes: (l)1900 mm x ( w)900 mm x (h) 600 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board/leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral whiteperformance specifications: maximum patient load should be 135 kgthickness mattress: 3+sandwitchconstruction: round corners yeshitlon thickness ( mm): 60hitlondensity (gm/dcm3): 23coir(both side) thicknessmm: 20density (gm/dcm3): 70, drc (%): 22quilting combination / layers:pilled foam – quilting (one side) thicknessmm 14pilled foam density gm/dcm3 18pu foam / epe sheet side walling thicknessmm 3total mattress thickness mm 87rexine (gsm): 150note: * finish product thickness should be measure from outer to outer surface. tolerance +5 mm , medicinetrolleytype i overall size902mm(l)x532mm(w)x915mm(h).top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg/shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm,seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , desk main desk should be of dimesion : 1200w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , staff chair type i chair of over all size: 58.0cm (w) x 56.5cm (d) x 87.5cm (h) & 48.0cm (sh)seat/back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm (w) x 27.0cm (h).*seat size: 46.0cm (w) x 40.0cm (d).armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. (1”) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. (1”) x 14bg. thick m.s. e.r.w. tube and powder coated. , wheel chair type i (l) 790 x (w) 600 x (h) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm (l) x 517 mm ( w) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck . 3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement. mx load bearing capacity should be 10 kg. , backpressurecompensated[bpc]oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [bpc] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l/m on an expanded lower scale forprecision setting at low flow and 5 15 l/m for general use. the humidifier bottle should be made up of unbreakable polycarbonate/ polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin /bsstd gas outlet front loaded din /bs std:supply, installation, testing and commissioning of din/british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din/british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din/bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din/british standard quick connect oxygen adapter(safety probe) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve 4 supply, installation, testing and commissioning of the ball valves [for dividing the pipelines into various zones for the case of maintenance] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [either fully open or fully closed]. it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [for dividing the pipelines into various zones for the case of maintenance] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [either fully open or fully closed]. it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline (in mtrs.) as per en 13348,12 mm (od) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline (in mtrs.) as per en 13348,15 mm (od) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline (in mtrs.) as per en 13348,22 mm (od) x 0.9 mm thickness total quantity : 1...

Bihar Medical Service And Infrastructure Corporation Ltd - Bihar

29777649 bids are invited for pile boring, providing and installation bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using direct mud circulation (dmc) or bailer and chisel technique by tripod and mechanical winch machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap).450mm dia piles (inclusive of carriage) , pcc providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 (1 cement : 3 coarse sand (zone iii) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) (inclusive of carriage) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland /portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. (inclusive of carriage) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 (1 cement : 4 coarse sand) (inclusive of carriage) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.(inclusive of carriage) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , reinforment steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory/workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone iii) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber/ neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. (glazing, paneling and dash fasteners to be paid for separately) :powder coated aluminium (minimum thickness of powder coating 50 micron) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . (cost of aluminium snap beading shall be paid in basic item):with float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) , upvc door providing and fixing of factory made upvc white colour casement door, upvc multichambered extruted frame, sash and mullion profile. frame duly reinforced with 1.2mm gi section box tpe chamber and sash with 1.5mm thick gi section (± 0.2mm) based on wind load calculations (shape and size according to upvc profiles), appropiate dimentions of upvc extruded glazing bead, epdm gasket (k/o type), seperate drainage system, ss34 grade friction hinges 2d/3d plate hinges, zinc alloy (white powder coated) casement handle, gi fastener 8x100 mm size for fixing frame to finish wall, plastic packer and caps and necessary steel screws etc.profile of frame and sash shall be metered cut and fusion welded at all corners, mullion shall be also fusion welded/joined mechanically including drilling of holes for fixing hardware and drainage of water etc. after fixing of frames , gap between frame and adjascent wall shall be filled with pu foaam / backer rod required size and the approved quantity. after that sealed with weather proof silicon sealant at both side, all complete as per approved drawing and direction of eic , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , soling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e/l, , tile 1 providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge :flamed finish granite stone slab jet black, cherry red, elitebrown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance (rh) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w/m k, fire performance as per (bs 476 pt 6 &7)in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mmwith 16 mm thick beveled tegular mineral fibre antimicrobial false ceiling tile confirming to iso 5 (class 100) specifications , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized (az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975. the wind load shall be as per provisions of is 875 (part iii). lgsfs frame shall be designed as per is: 801 using commercially available software such as frame cad pro 11.7/ staad pro v8i/ architekv2.5.16/ revit architecture 2011 or equivalent. proper usage of connection accessories like heavy duty tension ties, light duty hold ons, twist straps (to connect truss with wall frames), strong tie, tie rod, h brackets, boxing sections, l shaped angles for better structural stability. the framing section shall be cold form c type having minimum web depth 89 mm x 39mm flange x 11mm lip in required length as per structural design requirement duly punched with dimple/ slot at required locations as per approved drawings. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c/c of approved make. , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c/c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish.(cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by engineer in charge) 0.50 mm +/ 5% total coated thickness (tct) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal/vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm +/ 5% total coated thickness (tct) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling/ self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain (500 600mm). , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm +/ 5% total coated thickness (tct) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling/ self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness (tct), zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling/ self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings/ aprons. (upto 600 mm) , under deck insulation providing and fixing thermal insulation of ceiling (under deck insulation) with resin bonded rockwool conforming to is: 8183,density 48 kg/ m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg/m3,50 mm thick,wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , face panel providing and fixing in all exterior face panels breathable vapour barrier underneath the cementfiber board as per national building code 2009 complete as per direction of engineer in charge. , lap siding supplying and installation of moisture resistant/fire resistantlap siding 8 mm thick and width as per standard sizes made ofiber cement board with embossed decorative finish to give pleasing exterior fixed horizontally with staggered joints including minimum over lapof 32 mm external cement fibre boardconforming to is 14862:2000 offixed with self drilling / taping screws/fastners of approved make. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1 new work (two or more coats) over and including water tinnable priming coat with cement primer , ex. paint finishing walls with textured exterior paint of required shade : new work (two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/ 10 sqm sqm , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel 2 steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , road providing and laying c.c. pavement of mix m 25 with ready mixed concrete from batching plant. the ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc.complete as per specifications and directions of engineer in charge. (the panel shuttering work shall be paid for separately). (note: cement content considered in this item is @ 330 kg/cum. excess/less cement used as per design mix is payable/ recoverableseparately). , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 1 providing and fixing salem stainless steel a isi 304 (18/8) kitchen sink as per is: 13983 with ci brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required.kitchen sink with drain board 510x1040mm bowl depth 200mm. , phe 2 providing and fixing salem stainless steel a isi 304 (18/8) kitchen sink as per is: 13983 with ci brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required.sink without drain board 610x510 mm bowl depth 200mm. , phe 3 providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing:rectangular shape 453x357 mm , phe 4 providing and fixing toilet paper holder:c.p. brass , phe 5 providing and fixing water closet squatting pan (indian type w.c.pan) with 100 mm sand cast iron p or s trap, 10 litre low fixturescomplete, including cutting and making good the walls andlevel whitep.v.c. flushing cistern, including flush pipe, with manually controlleddevice (handle lever) conforming to is : 7231, with all fittings andfloors wherever required :white vitreous china orissa pattern w.c. pan of size580x440 mm with integral type foot rests , phe 6 providing and fixing white vitreous china pedestal type water closet (european type w.c. pan) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 7 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 8 providing and fixing cp brass 32mm size bottle trap of approved quality & make and as per the direction of engineer in charge..(sink & urinal) , phe 9 providing & fixingptmt towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealedfittings arrangement of approved quality and colour weighing not less than 88 gms , phe 10 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 11 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 12 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a) 15 mm nominal bore.15 mm nominal bore , phe 13 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size660x460 mm with a pair of 15 mm c.p. brass pillar tapswith elbow operated levers , phe 14 providing & fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. , phe 15 providing and fixing white vitreous china laboratory sink with c.i. brackets, c.p. brass chain with rubber plug, 40 mm c.p brass waste and 40mm c.p. brass trap with necessary c.p. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required :size 600x450x200 mm , phe 16 providing and fixing cp brass single lever telephonic wall mixer of quality & make as approved by engineer in charge . a) 15 mm nominal dia. , phe 17 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 18 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 19 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. , phe 20 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. (internal work) 40 mm dia, nominal bore , phe 21 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. (internal work)50 mm dia, nominal bore , phe 22 two or more coats on new work over an under coat ofsuitable shade with ordinary paint of approved brand andmanufacturetwo more coast on new work , phe 23 p/f m.s. cap 100 mm dia , phe 24 providing and fixing, upvcpipes 6 kg/cm2(is: 4985) including all fittings (plain or door) e.g. bends, junction, offsets, access pieces, jointing with rubber ring/solvent cement joints includingrequired suports,cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 25 providing and fixing, upvcpipes 6 kg/cm2(is: 4985) including all fittings (plain or door) e.g. bends, junction, offsets, access pieces, jointing with rubber ring/solvent cement joints includingrequired suports,cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 26 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. (i)single socketed pipes.110 mm diameter , phe 27 providing, fixing on wall face unplasticised pvc moulded fittings /accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 28 providing, fixing on wall face unplasticised pvc moulded fittings /accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings /accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 30 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4(1cement : 4 coarse sand) and making good the wall etc. complete.110 mm dia , phe 31 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 32 providing and fixing of gun metal gate valve with ci wheel of approved quality (screwed ends)25mm dia, nominal bore , phe 33 providing and fixing of gun metal gate valve with ci wheel of approved quality (screwed ends) 32 mm dia, nominal bore , phe 34 providing and fixing gun metal non return valve of approved quality (pn 1.6)40 nominal bore , phe 35 providing and fixing brass stop cock of approved quality15mm nominal bore , phe 36 butterfly valve (manual) with c i body ss disc, nitrile rubber seal & o ring pn 16 pressure rating for chilled water/hot eater circulation as specified 65 nominal bore , phe 37 butterfly valve (manual) with c i body ss disc, nitrile rubber seal & o ring pn 16 pressure rating for chilled water/hot eater circulation as specified80 nominal bore , phe 38 providing and fixing ball valve (brass) of approved quality, high or low pressure, with plastic floats complete25 mm nominal bore , ex. phe 1 providing and fixing c.i. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (the tail pieces, tapers etc if required will be paid separately) :50 mm dia , ex. phe 2 providing and fixing c.i. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (the tail pieces, tapers etc if required will be paid separately) :80 mm dia , ex. phe 3 providing and fixing c.i. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (the tail pieces, tapers etc if required will be paid separately) :100 mm dia , ex. phe 4 providing & fixing c.i.sluice valve(with cap)complete with bolts,nuts,rubber insertions etc.(the tail pieces if required will be paid separately)100 mm dia.pipe , ex. phe 5 providing & fixing c.i.sluice valve(with cap)complete with bolts,nuts,rubber insertions etc.(the tail pieces if required will be paid separately)150 mm dia.pipe , ex. phe 6 providing 250mm wide brick drain in cement mortar (1:6) with av. 150mm.clear depth and 250mm apron including cost of e/w. involved with 75mmcement concrete (1:4:8) over one brick designation 100 a flat soling inproper grade and slope at the base.the drain duly.plastered in cm. (1:3)with punning over exposed surface all complete as per buildingspecification and direction of e/l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil (hard or soft) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [hard/dense soil] pipes,cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 8 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil (hard or soft) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [hard/dense soil] pipes,cables etc.exceeding 80mm dia. exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class (light duty) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete. (for storm drainage)250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class (light duty) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete. (for storm drainage)300 mm dia rcc pipe , ex. phe 11 providing and laying non pressure np2 class (light duty) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete. (for storm drainage)450 mm dia rcc pipe , ex. phe 12 inside size 120x90 cm and 90 cm deep including c.i. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) :with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 , ex. phe 13 providing and fixing square mouth sw gully trap grade ‘a’ complete ci grating brick masonry chamber with bricks of class designation 75 and water tight ci cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 13.00 kg and frame to be not less than 5 kg. as per standard design.(cover min. 4.5 kg & frame min.2.7 kg )180x150 mm size p type with fps bricks , ex. phe 14 constructing masonry chamber 30x30x50 cm,inside with 75 class designation brick work in cement mortar 1:4 (1 cement:4 coarce sand) for stop cock complete with c.i. surface box 100x100x75mm (inside) with locking arrangement and rcc top slab 1:2:4 mix (1 cement : 2 corase sand: 4 graded stonr aggregate 20mm nominal size) necessary excavation foundation concret 1:5:10 (1 cement:5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortor 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design. , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement: 4 coarse sand) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with channel lid and rcc top slab 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement: 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , ex. phe 16 structual steel work welded in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. , ex. phe 17 making connection of gi distribution branch with gi main of 50 80mm nominal bore by providing and fixing tee, including cutting and threading the pipe etc. complete. , rain water harvesting 1 boring/drilling bore well of required dia for casing/ strainer pipe, bysuitable method prescribed in is:2800(part i ), including collecting sample from different strata , preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90m depth below ground level.300 mm dia , rain water harvesting 2 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing (cm) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150mm nominal size dia , rain water harvesting 3 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well screen(rms) pipes with ribs, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150 mm nominal size dia , rain water harvesting 4 supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 5 supplying, filling, spreading & levelling gravel of size range 5mm to 10mm, in recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 6 supplying, filling, spreading & levelling coarse sand of size range 1.5mm to 2mm, in recharge pit, in required thickness over gravel layer,for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 7 providing and fixing bail plug/ bottom plug of required dia to the bottom of pipe assembly of tube well as per is:2800(part i). 100 mm dia , rain water harvesting 8 making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and s.w. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 , rain water harvesting 9 constructing soak pit 1.20x1.20x1.20 m filled with brickbats including s.w. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 , tubewell 1 boring/drilling bore well of required dia for casing/ strainer pipe, bysuitable method prescribed in is:2800(part i ), including collecting sample from different strata , preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90m depth below ground level.300 mm dia , tubewell 2 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing (cm) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150mm nominal size dia , tubewell 3 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing (cm) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.100mm nominal size dia , tubewell 4 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well screen(rms) pipes with ribs, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.100 mm nominal size dia , tubewell 5 supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , tubewell 6 providing and fixing bail plug/ bottom plug of required dia to the bottom of pipe assembly of tube well as per is:2800(part i). 100 mm dia , submersible pump 35m deep boring with casing and pipe. supply of pipe etc supplying & installation of suitable 2hp submersible pump b.s or k.s.bor equivalent make with finolex cable 1x3x2.5 squmm(upto 50mtr) withflexible conduit 25mm dia, electrical out door pannel with required electrical fitting such as mcb of 0 25amp (havell or indocopp or mds make), volt & ampere meter (ae make), single phase preventer (minilac or vsp 1 make) starter (l&t or bch make) etc of approved make, 40mm hdpe pipe (25 mtr) and all accessories complete as per requirement of site. , water purifier and cooler 1 fitting and fixing single faucet storage type water cooler ( size 461 mm wide x 582 mm deep x 1217 mm height, weight 46 kg) fully stainless body having storage capacity of 40 ltrs, cooling capacity of 40 ltrs./hr. with hermetic type compressor, gas cooled motor equipped with over load protector, condensor for propeller type, thermostat autometically controlled temperature, refrigerent r 22, 230 volt, single phase 50 hertz, maximum current 2.3 amp including plug top and electrical lead wire connection upto 3 metres from the cooler, water inlet and drain out connections complete in all respects of voltas model no 40/40 tushar pss type or similar type of approved make. , water purifier and cooler 2 fitting and fixing water purifier for drinking purpose of capacity 6 litres/min, 5 purification system with reverse osmosis system with ultra ventilated membrane, tds500 to 2000 mgl/ppm, auto shut off with microswitch float manual flush facility, tds reduction 90% having automatic backwash system with filteration unit along with all accessories including plug top and electrical lead wire connection upto 3 metres from the purifier, water inlet and drain out connections complete in all respects similar to aquaguard or similar approved make (model aquasure elegant ro water purifier of size width 360 mm x height 430 mm x depth 235 mm and weight 8.5 kg). , fire extinguisher 1 providing and fixing carbon di oxide type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. capacity 4.5 kg. , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 6.0 kg. , electrical 1 wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm frls pvc insulated copper conductorsingle core cable in surface / recessed steel conduit, withmodular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. group c , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface /recessed steel conduit, 2 way modular switch, modular plate,suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , pvc conduit 1 supplying and fixing of following sizes of medium class 20mmpvc conduit along with accessories in surface/ recessincluding cutting the wall and making good the same incase of recessed conduit as required. , pvc conduit 2 supplying and fixing of following sizes of medium class 32mmpvc conduit along with accessories in surface/ recessincluding cutting the wall and making good the same incase of recessed conduit as required. , pvc conduit 3 supplying and fixing of following sizes of medium class 50mmpvc conduit along with accessories in surface/ recessincluding cutting the wall and making good the same incase of recessed conduit as required. , electrical 4 wiring for light/ power plug with 2x4 sq. mm frls pvcinsulated copper conductor single core cable in surface/recessed steel conduit alongwith 1 no. 4 sq. mm frls pvcinsulated copper conductor single core cable for loop earthingas required. , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 4 4 x 6 sq. mm + 2 x 6 sq. mm earth wire , wiring frls pvc insulated copper conductor 5 4 x 10 sq. mm + 2 x 6 sq. mm earth wire , wiring frls pvc insulated copper conductor 6 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s/f, gi box along with modular base & cover plate 1 1 or 2 module (75mm x 75mm) , s/f, gi box along with modular base & cover plate 2 3 module (100mm x 75mm) , s/f, gi box along with modular base & cover plate 3 4 module (125mmx75mm) , s/f, gi box along with modular base & cover plate 4 6 module (200mm x 75mm) , s/f, gi box along with modular base & cover plate 5 12 module (200mmx150mm) , s/f modular switch/ socket on the existing modular plate 1 5/6 amps switch , s/f modular switch/ socket on the existing modular plate 2 15/16 amp switch , s/f modular switch/ socket on the existing modular plate 3 3 pin 5/6 amp socket outlet , s/f modular switch/ socket on the existing modular plate 4 6 pin 15/16 amp socket outlet , s/f modular switch/ socket on the existing modular plate 5 telephone socket outlet , s/f modular switch/ socket on the existing modular plate 6 tv antenna socket outlet , s/f modular switch/ socket on the existing modular plate 7 bell push , fan regulator on the existing modular plate switch box supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. , call bell/ buzze supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. , electrical 5 supplying & fixing suitable size gi box wih modular plate and cover in front on surface or in recess including providing and fixing 25 a modular socket outlet and 25 a modular sp mcb, “c” curve including connections, painting etc. as required. (for ac/ geyser) , electrical 6 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface/ recessed steel/ pvc conduit as required. , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 9 providing and fixing circular/ hexagonal cast iron or m.s. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick m.s. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ m.s. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. clamp shall be made of 12 mm dia m.s. bar bent to shape as per standard drawing. , 40a fp isolator supplying and fixing following rating, four pole, 415 v, isolator in the existing mcb db complete with connections, testing andcommissioning etc. as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 11 supplying and fixing 20 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. , electrical 12 supplying and fixing 30 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. , electrical 17 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator)8 way (4 + 24), double door , electrical 18 supplying and fixing of following ways surface/ recess mounting, vertical type, 415 v, tpn mcb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 a tinned copper bus bar, common neutral link, earth bar, din bar for mounting mcbs (but without mcbs and incomer ) as required . (note : vertical type mcb tpdb is normally usedwhere 3 phase outlets are required.)4 way (4 + 12), double door , electrical 19 supplying and fixing of following ways surface/ recess mounting, vertical type, 415 v, tpn mcb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 a tinned copper bus bar, common neutral link, earth bar, din bar for mounting mcbs (but without mcbs and incomer ) as required . (note : vertical type mcb tpdb is normally usedwhere 3 phase outlets are required.)8 way (4 + 24), double door , electrical 20 supplying and fixing cable end box (loose wire box) suitable for following triple pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with testing and commissioning etc.as required. for 8 way, double door fp mcbdb , electrical 21 supplying and fixing cable end box (loose wire box) suitable for triple pole and neutral, sheet steel, vertical mcb distribution board, 415 v, on surface/ recess, complete with testing and commissioning etc. as required. , 25 a, rccb supplying and fixing following rating, double pole, (single phase and neutral), 240 v, residual current circuit breaker (rccb), having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40 a, rccb supplying and fixing following rating, double pole, (single phase and neutral), 240 v, residual current circuit breaker (rccb), having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , single pole mcb supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , triple pole mcb supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a tp mcb supplying and fixing 40 a rating, 240/415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40a tp mcb , 40a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40a fp mcb , 63a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 100a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , l/f pvc sheathed / xlpe power cable in trench 1 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 95 sq. mm and upto 185 sq. mm , l/f pvc sheathed / xlpe power cable in trench 2 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 185 sq. mm and upto 400 sq. mm , l/f pvc sheathed / xlpe power cable over cable tray above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm ms flat clamp) , s/m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 1 3.5c x 185 sqmm, aluminium conductor cable a2xfy , s/m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 2 3.5c x 150 sqmm, aluminium conductor cable a2xfy , s/m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 3 4c x 35 sqmm aluminium conductor cable a2xfy , cable tray 1 supplying and installing following size of perforated hot dipped galvanised iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 100 mm width x 50 mm depth x 1.6 mm thickness , cable tray 2 supplying and installing following size of perforated hot dipped galvanised iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 300 mm width x 50 mm depth x 1.6 mm thickness , cable tray 3 supplying and installing following size of perforated hot dipped galvanised iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 600 mm width x 62.5 mm depth x 2.0 mm thickness , cable tray “bends” 1 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.100 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 2 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.300 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 3 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.600 mm width x 62.5 mm depth x 2.0 mm thickness , mv cable 1 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring (round (w) or flat (f) as mentioned) and with all components as mentioned , specifications, complete as required.3.5c x 185 sqmm, aluminium conductor cable a2xfy , mv cable 2 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring (round (w) or flat (f) as mentioned) and with all components as mentioned , specifications, complete as required.3.5c x 150 sqmm, aluminium conductor cable a2xfy , mv cable 3 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring (round (w) or flat (f) as mentioned) and with all components as mentioned , specifications, complete as required. 4c x 35 sqmm aluminium conductor cable a2xfy , earthing 1 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. , earthing 2 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. , earthing 3 earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. , earthing 4 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. , earthing 5 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , earthing 6 providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required. , earthing 7 providing and fixing 25 mm x 5 mm g.i. strip in 40 mm dia g.i. pipe from earth electrode including connection with g.i. nut, bolt, spring, washer excavation and re filling etc. as required. , earthing 8 providing and fixing 25 mm x 5 mm copper strip in 40 mm dia g.i. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re filling etc. as required. , earthing 9 providing and fixing earth bus of 50 mm x 5 mm copper strip on surface for connections etc. as required. , earthing 10 providing and fixing earth bus of 50 mm x 5 mm gi strip on surface for connections etc. as required. , fiting & fixtures 1 supply and installation of regular/standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18/22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall/ ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made (2ft) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm/w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply) with output short circuit protection, surge protection.can be fixed directly into the wall/ ceiling , fiting & fixtures 4 supplying and fixing recess mounted 12 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 6 supply, installation, testing and commissioning of 400 mm sweep, 65w,blade material aluminium blades ,speed & oscillation 3 speed, pull cord for speed and oscillation.air delivery minimum 72 m³/min,speed minimun 1350 revolution per minute.suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong/grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm/w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver (smps based constant current supply) with output short circuit protection, surge protection & other reliability test. , fiting & fixtures 8 supplying installation testing & commissioning ofb22 based 9w led 3 star bulb with 850 lumen, 6k color temperature including holder. , fiting & fixtures 9 supplying installation testing & commissioning of black painted extruded aluminium housing. green / red led’s mounted inside the housing. laser engraved signage matter on single / double acrylic sheet fixed on one side suitable for wall / ceiling / suspension type single / double sided display. in double sided version black paper is inserted. ni cd battery back up to 2 hrs. (charged up to 8 10 hrs).mounting strings provided for pendent mounting operating voltage 150 280v ac ambient operating temperature. – 0 to 450c ingress protection – ip42.including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required.220208 besl 03 led ssd wbb green 240 3 8wor220209 besl 03 led ssd wbb red 240 3 8wor220210 besl 03 led dsd wbb green 240 3 8wor220211 besl 03 led dsd wbb red 240 3 8w , fiting & fixtures 10 supply, installation, testing and commissioning of 600 mm sweep, bee 5 star rated, ceiling fan with brush less direct current (bldc) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (cmm/w) minimum 6.85, air delivery minimum 135cmm, 350 rpm (tolerance as per is : 374 2019), thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. , civil & misc works1 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. , civil & misc works2 providing and fixing h.t. danger notice plate of 250 mm x 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. , civil & misc works3 supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) of size 60 cm x 60 cm at the bottom and 50 cm x 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. , civil & misc works4 supplying and fixing cable route marker with 10 cm x 10 cm x 5 mm thick g.i. plate with inscription there on, bolted /welded to 35 mm x 35 mm x 6 mm angle iron, 60 cm long and fixing the same in ground as required. , civil & misc works5 providing & fixing in position 1000 mm wide , electrical insulating rubber mats as per is 15652:2006, 2 mm thick, suitable up to 1.1 kv , fire retardant, no effect of acids, alkalis and transformer oils, moisture proof, high tensile strengthandtexture finish / cloth impression (anti slip , marking on top) , civil & misc works6 supply & fixing shock treatment chart duly mounted on a wooden frame with 5 mm thick glass as required ( approx front area 1.20 sq metre ) , 20 kvaups supplying, installation, testing and commissioningof online double conversion fully microprocessor based ,indoor type, compact ups system of following rating with igbt based pwm technology to achieve thd < 3% and input power factor of greater than 0.95 at 50% loading,suitable for three phase ac input voltage 380 v to 440 v, 50 hz +3% / 3 % and three phase ac output voltage 415 ± 1% volts & frequency 50 ± 0.5 hz , inbuilt isolation transformer, necessary vrla batteries of suitable size having 30 minutes back up time , mounting rack including and suitable size connecting cable (for ups to battery and battery to battery), static and maintenance bypass switch, snmp card for rs232/ ethernet ip computability for operation and monitoring etc. with all components as mentioned , specifications,complete as required.note : concerning vendor needs to furnish the battery sizing calculations at the time of ga approval and battery size has to be as per the approved ga drawing. , external lighting 1 supply and erection of 4 metre height hot dip galvanized octagonal street light pole with following arm with top dia 70 mm and bottom dia a/f 130 mm, made of 3 mm thick sheet along with base plate of size 220 x 220 x 12 mm , small door opening for junction box mounting with mcb & connector, cement concrete of 1:3:6 including excavation, refilling and suitable size foundation bolts with template and all complete jobas required. (but without pole collar) single arm , external lighting 2 supplying and fixing 40/45 watt led type street light with die cast aluminium housing for ingress protection of ip65 and complete with all accessories etc, onpole/building including connection with fr pvc insulated copper conductor cable and earthing the body etc. as required. , transformer supplying, installation testing and commissioning of following rating, distribution transformer, suitable for 3 phase, 50hz, ac supply,dyn 11 vector group,core made of good quality crgo, windings made of double wound copper with approved danger and arc flash signages and with all components as mentioned , specifications and sld and complete as required. power rating 250 kva , 11 kv ht dp structure / ht cable 1 supplying 11kv (earthed) grade, xlpe insulated, heavy duty frls type, armoured cables suitable for 11kv, 50hz, ac system with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel flat armouring and with all components as mentioned in boq, specifications and sld, complete as required.3 core x 240 sq. mm , 11 kv ht dp structure / ht cable 2 supply, installation, testing and commissioning of 11 kv dp structure as per cei & hpseb norms & comprising of the following, but not limited to it for completion of worksfor the followingrsj pole of 9.15 mt length of size 175 x 90 mm complete with suitable m.s. base plate welded at bottombase plate 2 nos. , indoor cable end termination 2 supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, xlpe aluminium conductor cable of 11 kv grade as required. 300 sq. mm , outdoor cable end termination supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, xlpe aluminium conductor cable of 11 kv grade as required. 300 sq. mm , main lt panel main lt panel (refer sld for detail)supply, installation, testing and commissioning of indoor floor mounted/ wall mounted, ip42(indoor) and ip55(outdoor), factory built, modular, sectionalised, compartmentalized, extendable type lt cubicle panel of suitable size suitable for operation on 433/415 volts, 50 hz ac 3 phase 4 wire supply system fabricated from crca sheet steel of 2mm thick for , apfc panel apfc panel (200 kvar) outoor type (refer sld for detail) , ip based cctv system 1 sitc of 2 megapixel @ 25fps, h.265 ip bullet camera,1/2.9 cmos with 2.8~12mm varifocal lens, 0 lux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d/n, 3d dnr, roi coding, poe,onvif,ip66 etc. complete as required. , cctv 2 sitc of 2 megapixel @ 25fps, h.265 ip dome camera,1/2.9 cmos with 3.6 fixed mm 0 lux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d/n, 3d dnr, roi coding, poe,onvif,ip66 etc. complete as required. , cctv 4 sitc of 32ch 4k ivr ,h.265/h.264 • 1080p real time • 4k display • dual lan • 8x hdd • raid •web plugin free h.265/h.264 compression technology 4k display for clear monitoring up to 1080p 16ch decoding ability smart search ii smart vca event searchsupport raid 0, 1, 5 supported to prevent from recording data loss browsers supported: ie , smart functions : target count, electric fence, face detection, humaniod detection,retrograde detection, leave position detectio output, local & network backup etc. complete as required. , cctv 5 sitc of harddiskdrive8tb,24/7surveillance category only complete etc as required.etc.all complete , cctv 6 sitc of 55 led narrow bazel for monitoring for nvr server etc. all complete. , cctv 7 sitc of rj 45 outlets near the cameras etc. all complete. etc. all complete. , cctv 8 sitc of cat 6 patch cords 1 meter high quality four pair twisted stranded cable terminated with rj45 modular plugs at both the ends. , integrated it and epabx system sitcof cat 6 48 port jack panel for data as per given specification etc. all complete. , epabx system 2 sitcof cat 6 48 port jack panel for voice as per given specification etc. all complete. , epabx system 3 sitc of lszh cat 6 speed unshielded twisted pair computer cable with 23 awg solid copper conductors in existing concealed/surface conduits/raceways complete 305 mtr. roll as per specification etc. all complete. , epabx system 4 sitc of cat6 io, face plate, wall box combo2 port etc. all complete. , epabx system 5 sitcof cat 6 mounting cords 7 feet for data as per given specification etc. all complete. , epabx system 6 sitcof cat 6 patch cords 4 feet for telephone as per given specification etc. all complete. , epabx system 7 sitc of 24 port l2 managed 10/100/1000 mbps non poe switch with 4 sfp port , for data pointsrack mountable etc. all complete. , epabx system 8 sitc of 24 port l2 managed poe 10/100/1000 mbps switch with 4 sfp port , for cctv rack mountable etc. all complete. , epabx system 9 sitc of 24 port smart managed non poe with 4 sfp port rack mountable etc. all complete. , epabx system 10 sitc of 15 u mountingrack with ventilation, sliding shelves, power strips, etc. all complete. , epabx system 11 sitc of ip pbx for with 8 trunk 1 pri& 8 digital and 32 analog extension expendble upto 64 extesionsy etc all complete. , epabx system 12 25 pair riser cable , epabx system 13 mdf box25 pair with 20 pairkrone module , epabx system 14 supply, installation, testing & commissioning of analog phone with speaker , small display etc. all complete. , epabx system 15 client workstation supply, installation, testing & commissioning of client workstation as per following specifications:intel core i5 7700k, 4.2ghz, os genuine microsoft microsoft® windows 10 enterprise 64 bit, ram 16gb, memory 500 gbssd +1tb hdd 7200 rpm class graphic card in built processor graphics (gpu):intel® hd graphics 630 and geforce gtx 970 4gb pcie x 16 lp supporting 2/4 monitors., two(2) pci express expansion slots 2/4 usb, 3.0 serial, and 2 hdmi/vga adaptor, cd/dvd rom.; usb keyboard and mouse, ups, associated cables etc. and other required software to control nvr in control room including centralized video management software as per the requirement of the successful operation of the surveillance system complete as required in accordance with laid specification or upto the satisfaction of engineer in charge. , signage 1 providing & fixing of building direction signage mounted on pole, with pole of 100x100mm shs (square hollow section) of height of 5600mm, and sign size of 900x1050, sign made of aluminiu c section of 60mm with internal framing to support the frame in ms tubes hollow section, frame work duly painted with anti rust coatings, with facia of 3mm thick exterior grade aluminium composite panel, cladded with uv cured digital printed retroreflective sheet of 3m make, and back panel of 3mm exterior grade acp, all pipes to be painted in approved color. cost shall includecost towards installation, including excuvation and filling up with specified pcc and fixing of foundation bolts as specified, also it shall include the designing charges.all complete as per direction by engineer in charge. , signage 2 providing & fixing of prohibition sign silk screen printed of approved colors, on acp of exterior grade, of size 300x300mm, all fixtures in stainless steel as per design, it shall include the designing charges .all complete as per direction by engineer in charge. , signage 3 providing & fixing traffic regulatory parking signage mounted on pole, with pole of 50x50mm shs (square hollow section) of height of 300mm, and sign size of 750x750, sign made of aluminium sheet of 3 mm thickness with aluminium supported profile to the frame of ms tube hollow section, aluminium sheet to be cladded with uv printed retroreflective sheet of 3m make frame work duly painted with anti rust coatings., all pipe to be painted in apppproved color. cost shall include cost towards installation, including excuvation and filling up with specified pcc and fixing of foundation bolts as specified, also it shall include the designing charges.all complete as per direction by engineer in charge. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , 2 tr air conditioning 1 split ac (inverter model): supply, installation, testing, commissioning of split type wall mounted air conditioning units of following capacity including inddor, outdoor unit fitted with inverter based rotary compressor fitted with rotary compressor, copper condensor and first charge refrigent r410a/ eco friendly green gas only, all complete including all electrical connections to the electrical power supply system of the building, includingbut not limited to supply of all electrical plugs, etc.,as necessary,lengthening of all electrical wires of ac units ( both indoor and outdoor), drain pipe andincluding suitable voltage stabilisers, etc. so as to place them in a concealed manner in the desired position. the copper pipes and electrical cables shall be concealed in approved manner and neatly run in straight lines in a workman like manner with proper supports. complete supply and installation of split2 tr star rating 3 star , refrigerant piping 1 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work (19mm / 13 mm thick) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 25 mm od, wall thickness >= 1.2 mm (insulation 19 mm thick) , refrigerant piping 2 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work (19mm / 13 mm thick) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 19.1 mm od, wall thickness >= 1.0 mm (insulation 13 mm thick) , refrigerant piping 3 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work (19mm / 13 mm thick) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 15.9 mm od, wall thickness >= 0.8 mm (insulation 13 mm thick) , refrigerant piping 4 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work (19mm / 13 mm thick) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 9.5 mm od, wall thickness >= 0.8 mm (insulation 13 mm thick) , drain piping 1 providing and fixing of cpvc 6 kg/cm2 drainpiping complete with fittings, supports, 6 mm thick closed cell elastomeric insulation as per specifications and drawings. 20 mm , drain piping 2 providing and fixing of cpvc 6 kg/cm2 drainpiping complete with fittings, supports, 6 mm thick closed cell elastomeric insulation as per specifications and drawings. 32 mm , main oxygen manifold supply, installation, testing and commissioning of following gas manifold system (excluding cylinders). the manifold is configured for designed numbers of cylinders and is suitable to withstand a pressure of 145 kg/cm2, along withhigh pressure copper annealed tail pipes with end brass adapter suitable for cylinders and manifold. top frame comprising of high pressure copper pipes of size 1/2” nb x 15swg with high pressure brass fittings made of high tensile brass and connections through nonreturn valves, the design of middle and bottomframes is provided to fit both round and flat bottom cylinders safely. the manifold is tested (hydraulically) at 3500 psig. (it should be ce and iso 13485 certified) mani fold oxygen manifold 4 + 4 cylinder banks complete with nrv, middle frame, bottom frame with ce marked, , emergency manifold emergency oxygen manifold 01 + 01 cylinder emergency manifold with complete regulator, nrv, middle frame & bottom frame, , control panelfor oxygen fully automatic three port control panel for oxygen supply, installation, testing and commissioning of automatic manifold control panel would provide a duty or standby gas supply from two cylinder banks with automaticchangeover the manifold indicates local status and has a remote indicator facility. automaticmanifold control panel would be designed to supply the mgps with a constant pressure supply via a control panel form two equal banks of cylinders and the changeover from the , emergency manifold line regulator emergency manifold line regulator supply, installation, testing and commissioning of emergency manifold line regulator i n p u t p r e s s u r e 1 5 0 k g / c m 2 working pressure 4 kg/cm2 it should be ce and iso 13485 certified.oxygen input pressure 150 kg/cm2 working pressure 4 kg/cm2capacity : 1500 lpm , cylinderconnectingpipe (pig tail) supply, installation, testing and commissioning of cylinder connecting pipe (pig tail) made up of flexible ss hose with safety cord 5/8 inch bsp gland nut and one side 1/2 inch bsp internal threads having one meter length.(oxygen 24 , n2o 10,co2 4) , backpressurecompensated[bpc]oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [bpc] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l/m on an expanded lower scale forprecision setting at low flow and 5 15 l/m for general use. the humidifier bottle should be made up of unbreakable polycarbonate/ polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin /bsstd gas outlet front loaded din /bs std:supply, installation, testing and commissioning of din/british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din/british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din/bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din/british standard quick connect oxygen adapter(safety probe) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve, supply, installation, testing and commissioning of the ball valves [for dividing the pipelines into various zones for the case of maintenance] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [either fully open or fully closed]. it should be ce and iso 13485 certified.42mm , isolation valve 2 supply, installation, testing and commissioning of the ball valves [for dividing the pipelines into various zones for the case of maintenance] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [either fully open or fully closed]. it should be ce and iso 13485 certified 28mm , isolation valve 3 supply, installation, testing and commissioning of the ball valves [for dividing the pipelines into various zones for the case of maintenance] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [either fully open or fully closed]. it should be ce and iso 13485 certified 22mm , isolation valve 4 supply, installation, testing and commissioning of the ball valves [for dividing the pipelines into various zones for the case of maintenance] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [either fully open or fully closed]. it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [for dividing the pipelines into various zones for the case of maintenance] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [either fully open or fully closed]. it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline (in mtrs.) as per en 13348,12 mm (od) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline (in mtrs.) as per en 13348,15 mm (od) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline (in mtrs.) as per en 13348,22 mm (od) x 0.9 mm thickness , pipeline 4 medical grade copper pipeline (in mtrs.) as per en 13348,28 mm (od) x 0.9 mm thickness , pipeline 5 medical grade copper pipeline (in mtrs.) as per en 13348,42 mm (od) x 1.2 mm thickness , hospital sheet patient bedtype iii with mattress overall sizes: (l)2268 mm x ( w)922 mm x (h) 610 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crca , paediatric bed with mattress paediatric bed of overall sizes in mm: 1500 (l) x 850 (w) x 1210 (h)flat single section bed with grille frame on 4 sides.suitable for children up to 12 years.drop down grill frame on both sides for protection of the patient.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board/leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral white , bed side locker type i over all dimension :402mmlx422mm wx840mm ht .locker should have one cabinet and one drawer unit .both provided with cam lock .there should be gap between drawer and unit to keep general items for frequesnt use castors are provided for easy handling .drawer made up of crca sheet 1 mm thick and has ball slide for easy operation .top ss 304 sheet 0.8 mm thick castors 50 mmdia ,hamdle abs ..powder coating of epoxy polyester , medicinetrolleytype i overall size902mm(l)x532mm(w)x915mm(h).top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg/shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm,seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , strecher on trolley type i 2005mm(l)x666mm(w)x827mm(h).the trolley should be made of 31.75 and 25.4 mm dia 1.6 mm thick erw tube.holder for stretcher should be made up of mild steel.castor should be of 200 mm dia , diagonal locking castor.stretcher should be made up oferw tubeof dia 25.4 mm and thickness 1.6 mm.top sheet should be made of crca sheetof thickness 1.2 mm with contour shape to accommodate patient.iv pole holder should be made ofms .maximum safe work load should be 135 kg.to ensure qood quality welding co2 argonprocess should be adhered to.all metal componentsshould be pre treated with zinc phosphating in 9 tank porcess and then powder coated with anti microbialepoxy polyster powder coating.goods should be supplied in knocked down construction to reduce carbon emission. performance test :proof loading test , cycle tests , impact test, salt spray test, castor break test,the manufacturer should compilant with iso 9001, 14001, 13485, ohsas 1800 and ce certification. , doctor desk type x s/f/f executive table main desk should be of dimesion : 1350w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. side panels : (black) made form 18mm thick plt with pvc lipping.modesty panel : made form 18mm thick plt with pvc lipping. bigger upper panel in black and smaller lower panel in white cedar. made from 18mm thick plt with pvc lipping. mobile pedestal : one box and one filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , chair type iii s/f/f executive chair1) seat/back assembly: the seat and back are made up of 1.2 cm. thick hot pressed plywood, upholstered withfabric upholstery covers and moulded polyurethane foam. the back foam is designed with contoured lumbar support for extra comfort. the seat has extra thick foam on front edge to give comfort to popliteal area.high back size : 47.5 cm (w) x 69.5 cm (h)seat size : 47.0 cm. (w) x 48.0 cm. (d) 2) polyurethane foam: the polyurethane foam is moulded with density = 45 +/ 2 kg/m 3and hardness = 20 +/ 2at 25% compression. 3) armrests: the one piece armrests are injection moulded from black co polymer polypropylene. 4) center tilt synchro mechanism : the mechanism is designed with the following features:· 360 revolving type. · upright position locking. · tilt tension adjustment.· seat/back tilting ratio of 1:3 (60 seat tilt/180 back tilt). 5) pneumatic height adjustment : the pneumatic height adjustment has anadjustment stroke of 12.0 cm. 6) telescopic bellow assembly : the bellow is 3 piece telescopic type and injection moulded in black polypropylene. 7) pedestal assembly : the pedestal is injection moulded in black 30% glass filled nylonand fitted with 5 nos. twin wheel castors. the pedestal is 66.0cm pitch center dia. (76.0 cm with castors.) 8) twin wheel castors : the twin wheel castors are injection moulded in black nylon. , staff chair type i chair of over all size: 58.0cm (w) x 56.5cm (d) x 87.5cm (h) & 48.0cm (sh)seat/back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm (w) x 27.0cm (h).*seat size: 46.0cm (w) x 40.0cm (d).armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. (1”) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. (1”) x 14bg. thick m.s. e.r.w. tube and powder coated. , visiter chair type v s/f/f visitor chair1) seat/back assembly: the seat and back are made up of 1.2 cm. thick hot pressed plywood, upholstered with fabric upholstery covers and moulded polyurethane foam. the back foam is designed with contoured lumbar support for extra comfort. the seat has extra thick foam on front edge to give comfort to popliteal area. mid back size : 47.5 cm. (w) x 58.0cm. (h)seat size : 47.0 cm. (w) x 48.0 cm. (d) 2) polyurethane foam: the polyurethane foam is moulded with density = 45 +/ 2 kg/m 3and hardness = 20 +/ 2at 25% compression. 3) armrests: the one piece armrests are injection moulded from black co polymer polypropylene. 4) tubular frame : the powder coated tubular frame is cantilever type & made of dia 25.4mm x 2mm thk m.s. er.w. tube. , wheel chair type i (l) 790 x (w) 600 x (h) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm (l) x 517 mm ( w) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck .3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement.mx load bearing capacity should be 10 kg. , instrument cabinet type i overall dimensions of 900mmwx 1990mmhx450mmd and should have transparent doors and sides with steel frame work. transparent portion of this cupboard should be made of acrylic of 4mm thick. this cabinet should have 5 adjustable acrylic shelves each of 6 mm thickness. three way lock should be provided of 6 levers. in the front door there should be 4 acrylic sheets and 2 each on both the sides. metal used should be of crca and powder coated for finish. to be provided with rubber shoes to prevent direct contact of cabinet and floor. , hospital curtain tracks & i.v. tree system supply installation testing & commissioning of cubical tracks system made of powder coated aluminium alloy,stain free polyster fabric ,water repellent curtains ,smooth movement ,non sticking runnner with stainless steel hooks made from mirror finish stainless steel ,adjustable height with all accessories. total quantity : 1...

Bihar Medical Service And Infrastructure Corporation Ltd - Bihar

29776863 bids are invited for pile boring, providing and installation bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using direct mud circulation (dmc) or bailer and chisel technique by tripod and mechanical winch machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap).450mm dia piles (inclusive of carriage) , pcc providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 (1 cement : 3 coarse sand (zone iii) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) (inclusive of carriage) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland /portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. (inclusive of carriage) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 (1 cement : 4 coarse sand) (inclusive of carriage) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.(inclusive of carriage) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , reinforment steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory/workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone iii) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber/ neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. (glazing, paneling and dash fasteners to be paid for separately) :powder coated aluminium (minimum thickness of powder coating 50 micron) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . (cost of aluminium snap beading shall be paid in basic item):with float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) , upvc door providing and fixing of factory made upvc white colour casement door, upvc multichambered extruted frame, sash and mullion profile. frame duly reinforced with 1.2mm gi section box tpe chamber and sash with 1.5mm thick gi section (± 0.2mm) based on wind load calculations (shape and size according to upvc profiles), appropiate dimentions of upvc extruded glazing bead, epdm gasket (k/o type), seperate drainage system, ss34 grade friction hinges 2d/3d plate hinges, zinc alloy (white powder coated) casement handle, gi fastener 8x100 mm size for fixing frame to finish wall, plastic packer and caps and necessary steel screws etc.profile of frame and sash shall be metered cut and fusion welded at all corners, mullion shall be also fusion welded/joined mechanically including drilling of holes for fixing hardware and drainage of water etc. after fixing of frames , gap between frame and adjascent wall shall be filled with pu foaam / backer rod required size and the approved quantity. after that sealed with weather proof silicon sealant at both side, all complete as per approved drawing and direction of eic , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , soling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e/l, , tile 1 providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge :flamed finish granite stone slab jet black, cherry red, elitebrown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance (rh) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w/m k, fire performance as per (bs 476 pt 6 &7)in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mmwith 16 mm thick beveled tegular mineral fibre antimicrobial false ceiling tile confirming to iso 5 (class 100) specifications , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized (az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975. the wind load shall be as per provisions of is 875 (part iii). lgsfs frame shall be designed as per is: 801 using commercially available software such as frame cad pro 11.7/ staad pro v8i/ architekv2.5.16/ revit architecture 2011 or equivalent. proper usage of connection accessories like heavy duty tension ties, light duty hold ons, twist straps (to connect truss with wall frames), strong tie, tie rod, h brackets, boxing sections, l shaped angles for better structural stability. the framing section shall be cold form c type having minimum web depth 89 mm x 39mm flange x 11mm lip in required length as per structural design requirement duly punched with dimple/ slot at required locations as per approved drawings. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c/c of approved make. , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c/c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish.(cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by engineer in charge) 0.50 mm +/ 5% total coated thickness (tct) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal/vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm +/ 5% total coated thickness (tct) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling/ self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain (500 600mm). , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm +/ 5% total coated thickness (tct) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling/ self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness (tct), zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling/ self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings/ aprons. (upto 600 mm) , under deck insulation providing and fixing thermal insulation of ceiling (under deck insulation) with resin bonded rockwool conforming to is: 8183,density 48 kg/ m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg/m3,50 mm thick,wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , face panel providing and fixing in all exterior face panels breathable vapour barrier underneath the cementfiber board as per national building code 2009 complete as per direction of engineer in charge. , lap siding supplying and installation of moisture resistant/fire resistantlap siding 8 mm thick and width as per standard sizes made ofiber cement board with embossed decorative finish to give pleasing exterior fixed horizontally with staggered joints including minimum over lapof 32 mm external cement fibre boardconforming to is 14862:2000 offixed with self drilling / taping screws/fastners of approved make. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1 new work (two or more coats) over and including water tinnable priming coat with cement primer , ex. paint finishing walls with textured exterior paint of required shade : new work (two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/ 10 sqm sqm , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel 2 steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , road providing and laying c.c. pavement of mix m 25 with ready mixed concrete from batching plant. the ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc.complete as per specifications and directions of engineer in charge. (the panel shuttering work shall be paid for separately). (note: cement content considered in this item is @ 330 kg/cum. excess/less cement used as per design mix is payable/ recoverableseparately). , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 1 providing and fixing salem stainless steel a isi 304 (18/8) kitchen sink as per is: 13983 with ci brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required.kitchen sink with drain board 510x1040mm bowl depth 200mm. , phe 2 providing and fixing salem stainless steel a isi 304 (18/8) kitchen sink as per is: 13983 with ci brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required.sink without drain board 610x510 mm bowl depth 200mm. , phe 3 providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing:rectangular shape 453x357 mm , phe 4 providing and fixing toilet paper holder:c.p. brass , phe 5 providing and fixing water closet squatting pan (indian type w.c.pan) with 100 mm sand cast iron p or s trap, 10 litre low fixturescomplete, including cutting and making good the walls andlevel whitep.v.c. flushing cistern, including flush pipe, with manually controlleddevice (handle lever) conforming to is : 7231, with all fittings andfloors wherever required :white vitreous china orissa pattern w.c. pan of size580x440 mm with integral type foot rests , phe 6 providing and fixing white vitreous china pedestal type water closet (european type w.c. pan) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 7 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 8 providing and fixing cp brass 32mm size bottle trap of approved quality & make and as per the direction of engineer in charge..(sink & urinal) , phe 9 providing & fixingptmt towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealedfittings arrangement of approved quality and colour weighing not less than 88 gms , phe 10 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 11 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 12 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a) 15 mm nominal bore.15 mm nominal bore , phe 13 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size660x460 mm with a pair of 15 mm c.p. brass pillar tapswith elbow operated levers , phe 14 providing & fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. , phe 15 providing and fixing white vitreous china laboratory sink with c.i. brackets, c.p. brass chain with rubber plug, 40 mm c.p brass waste and 40mm c.p. brass trap with necessary c.p. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required :size 600x450x200 mm , phe 16 providing and fixing cp brass single lever telephonic wall mixer of quality & make as approved by engineer in charge . a) 15 mm nominal dia. , phe 17 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 18 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 19 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. , phe 20 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. (internal work) 40 mm dia, nominal bore , phe 21 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. (internal work)50 mm dia, nominal bore , phe 22 two or more coats on new work over an under coat ofsuitable shade with ordinary paint of approved brand andmanufacturetwo more coast on new work , phe 23 p/f m.s. cap 100 mm dia , phe 24 providing and fixing, upvcpipes 6 kg/cm2(is: 4985) including all fittings (plain or door) e.g. bends, junction, offsets, access pieces, jointing with rubber ring/solvent cement joints includingrequired suports,cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 25 providing and fixing, upvcpipes 6 kg/cm2(is: 4985) including all fittings (plain or door) e.g. bends, junction, offsets, access pieces, jointing with rubber ring/solvent cement joints includingrequired suports,cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 26 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. (i)single socketed pipes.110 mm diameter , phe 27 providing, fixing on wall face unplasticised pvc moulded fittings /accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 28 providing, fixing on wall face unplasticised pvc moulded fittings /accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings /accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 30 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4(1cement : 4 coarse sand) and making good the wall etc. complete.110 mm dia , phe 31 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 32 providing and fixing of gun metal gate valve with ci wheel of approved quality (screwed ends)25mm dia, nominal bore , phe 33 providing and fixing of gun metal gate valve with ci wheel of approved quality (screwed ends) 32 mm dia, nominal bore , phe 34 providing and fixing gun metal non return valve of approved quality (pn 1.6)40 nominal bore , phe 35 providing and fixing brass stop cock of approved quality15mm nominal bore , phe 36 butterfly valve (manual) with c i body ss disc, nitrile rubber seal & o ring pn 16 pressure rating for chilled water/hot eater circulation as specified 65 nominal bore , phe 37 butterfly valve (manual) with c i body ss disc, nitrile rubber seal & o ring pn 16 pressure rating for chilled water/hot eater circulation as specified80 nominal bore , phe 38 providing and fixing ball valve (brass) of approved quality, high or low pressure, with plastic floats complete25 mm nominal bore , ex. phe 1 providing and fixing c.i. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (the tail pieces, tapers etc if required will be paid separately) :50 mm dia , ex. phe 2 providing and fixing c.i. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (the tail pieces, tapers etc if required will be paid separately) :80 mm dia , ex. phe 3 providing and fixing c.i. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (the tail pieces, tapers etc if required will be paid separately) :100 mm dia , ex. phe 4 providing & fixing c.i.sluice valve(with cap)complete with bolts,nuts,rubber insertions etc.(the tail pieces if required will be paid separately)100 mm dia.pipe , ex. phe 5 providing & fixing c.i.sluice valve(with cap)complete with bolts,nuts,rubber insertions etc.(the tail pieces if required will be paid separately)150 mm dia.pipe , ex. phe 6 providing 250mm wide brick drain in cement mortar (1:6) with av. 150mm.clear depth and 250mm apron including cost of e/w. involved with 75mmcement concrete (1:4:8) over one brick designation 100 a flat soling inproper grade and slope at the base.the drain duly.plastered in cm. (1:3)with punning over exposed surface all complete as per buildingspecification and direction of e/l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil (hard or soft) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [hard/dense soil] pipes,cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 8 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil (hard or soft) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [hard/dense soil] pipes,cables etc.exceeding 80mm dia. exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class (light duty) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete. (for storm drainage)250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class (light duty) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete. (for storm drainage)300 mm dia rcc pipe , ex. phe 11 providing and laying non pressure np2 class (light duty) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete. (for storm drainage)450 mm dia rcc pipe , ex. phe 12 inside size 120x90 cm and 90 cm deep including c.i. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) :with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 , ex. phe 13 providing and fixing square mouth sw gully trap grade ‘a’ complete ci grating brick masonry chamber with bricks of class designation 75 and water tight ci cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 13.00 kg and frame to be not less than 5 kg. as per standard design.(cover min. 4.5 kg & frame min.2.7 kg )180x150 mm size p type with fps bricks , ex. phe 14 constructing masonry chamber 30x30x50 cm,inside with 75 class designation brick work in cement mortar 1:4 (1 cement:4 coarce sand) for stop cock complete with c.i. surface box 100x100x75mm (inside) with locking arrangement and rcc top slab 1:2:4 mix (1 cement : 2 corase sand: 4 graded stonr aggregate 20mm nominal size) necessary excavation foundation concret 1:5:10 (1 cement:5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortor 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design. , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement: 4 coarse sand) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with channel lid and rcc top slab 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement: 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , ex. phe 16 structual steel work welded in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. , ex. phe 17 making connection of gi distribution branch with gi main of 50 80mm nominal bore by providing and fixing tee, including cutting and threading the pipe etc. complete. , rain water harvesting 1 boring/drilling bore well of required dia for casing/ strainer pipe, bysuitable method prescribed in is:2800(part i ), including collecting sample from different strata , preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90m depth below ground level.300 mm dia , rain water harvesting 2 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing (cm) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150mm nominal size dia , rain water harvesting 3 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well screen(rms) pipes with ribs, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150 mm nominal size dia , rain water harvesting 4 supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 5 supplying, filling, spreading & levelling gravel of size range 5mm to 10mm, in recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 6 supplying, filling, spreading & levelling coarse sand of size range 1.5mm to 2mm, in recharge pit, in required thickness over gravel layer,for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 7 providing and fixing bail plug/ bottom plug of required dia to the bottom of pipe assembly of tube well as per is:2800(part i). 100 mm dia , rain water harvesting 8 making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and s.w. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 , rain water harvesting 9 constructing soak pit 1.20x1.20x1.20 m filled with brickbats including s.w. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 , tubewell 1 boring/drilling bore well of required dia for casing/ strainer pipe, bysuitable method prescribed in is:2800(part i ), including collecting sample from different strata , preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90m depth below ground level.300 mm dia , tubewell 2 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing (cm) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150mm nominal size dia , tubewell 3 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing (cm) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.100mm nominal size dia , tubewell 4 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well screen(rms) pipes with ribs, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.100 mm nominal size dia , tubewell 5 supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , tubewell 6 providing and fixing bail plug/ bottom plug of required dia to the bottom of pipe assembly of tube well as per is:2800(part i). 100 mm dia , submersible pump 35m deep boring with casing and pipe. supply of pipe etc supplying & installation of suitable 2hp submersible pump b.s or k.s.bor equivalent make with finolex cable 1x3x2.5 squmm(upto 50mtr) withflexible conduit 25mm dia, electrical out door pannel with required electrical fitting such as mcb of 0 25amp (havell or indocopp or mds make), volt & ampere meter (ae make), single phase preventer (minilac or vsp 1 make) starter (l&t or bch make) etc of approved make, 40mm hdpe pipe (25 mtr) and all accessories complete as per requirement of site. , water purifier and cooler 1 fitting and fixing single faucet storage type water cooler ( size 461 mm wide x 582 mm deep x 1217 mm height, weight 46 kg) fully stainless body having storage capacity of 40 ltrs, cooling capacity of 40 ltrs./hr. with hermetic type compressor, gas cooled motor equipped with over load protector, condensor for propeller type, thermostat autometically controlled temperature, refrigerent r 22, 230 volt, single phase 50 hertz, maximum current 2.3 amp including plug top and electrical lead wire connection upto 3 metres from the cooler, water inlet and drain out connections complete in all respects of voltas model no 40/40 tushar pss type or similar type of approved make. , water purifier and cooler 2 fitting and fixing water purifier for drinking purpose of capacity 6 litres/min, 5 purification system with reverse osmosis system with ultra ventilated membrane, tds500 to 2000 mgl/ppm, auto shut off with microswitch float manual flush facility, tds reduction 90% having automatic backwash system with filteration unit along with all accessories including plug top and electrical lead wire connection upto 3 metres from the purifier, water inlet and drain out connections complete in all respects similar to aquaguard or similar approved make (model aquasure elegant ro water purifier of size width 360 mm x height 430 mm x depth 235 mm and weight 8.5 kg). , fire extinguisher 1 providing and fixing carbon di oxide type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. capacity 4.5 kg. , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 6.0 kg. , electrical 1 wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm frls pvc insulated copper conductorsingle core cable in surface / recessed steel conduit, withmodular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. group c , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface /recessed steel conduit, 2 way modular switch, modular plate,suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , pvc conduit 1 supplying and fixing of following sizes of medium class 20mmpvc conduit along with accessories in surface/ recessincluding cutting the wall and making good the same incase of recessed conduit as required. , pvc conduit 2 supplying and fixing of following sizes of medium class 32mmpvc conduit along with accessories in surface/ recessincluding cutting the wall and making good the same incase of recessed conduit as required. , pvc conduit 3 supplying and fixing of following sizes of medium class 50mmpvc conduit along with accessories in surface/ recessincluding cutting the wall and making good the same incase of recessed conduit as required. , electrical 4 wiring for light/ power plug with 2x4 sq. mm frls pvcinsulated copper conductor single core cable in surface/recessed steel conduit alongwith 1 no. 4 sq. mm frls pvcinsulated copper conductor single core cable for loop earthingas required. , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 4 4 x 6 sq. mm + 2 x 6 sq. mm earth wire , wiring frls pvc insulated copper conductor 5 4 x 10 sq. mm + 2 x 6 sq. mm earth wire , wiring frls pvc insulated copper conductor 6 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s/f, gi box along with modular base & cover plate 1 1 or 2 module (75mm x 75mm) , s/f, gi box along with modular base & cover plate 2 3 module (100mm x 75mm) , s/f, gi box along with modular base & cover plate 3 4 module (125mmx75mm) , s/f, gi box along with modular base & cover plate 4 6 module (200mm x 75mm) , s/f, gi box along with modular base & cover plate 5 12 module (200mmx150mm) , s/f modular switch/ socket on the existing modular plate 1 5/6 amps switch , s/f modular switch/ socket on the existing modular plate 2 15/16 amp switch , s/f modular switch/ socket on the existing modular plate 3 3 pin 5/6 amp socket outlet , s/f modular switch/ socket on the existing modular plate 4 6 pin 15/16 amp socket outlet , s/f modular switch/ socket on the existing modular plate 5 telephone socket outlet , s/f modular switch/ socket on the existing modular plate 6 tv antenna socket outlet , s/f modular switch/ socket on the existing modular plate 7 bell push , fan regulator on the existing modular plate switch box supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. , call bell/ buzze supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. , electrical 5 supplying & fixing suitable size gi box wih modular plate and cover in front on surface or in recess including providing and fixing 25 a modular socket outlet and 25 a modular sp mcb, “c” curve including connections, painting etc. as required. (for ac/ geyser) , electrical 6 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface/ recessed steel/ pvc conduit as required. , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 9 providing and fixing circular/ hexagonal cast iron or m.s. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick m.s. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ m.s. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. clamp shall be made of 12 mm dia m.s. bar bent to shape as per standard drawing. , 40a fp isolator supplying and fixing following rating, four pole, 415 v, isolator in the existing mcb db complete with connections, testing andcommissioning etc. as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 11 supplying and fixing 20 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. , electrical 12 supplying and fixing 30 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. , electrical 17 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator)8 way (4 + 24), double door , electrical 18 supplying and fixing of following ways surface/ recess mounting, vertical type, 415 v, tpn mcb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 a tinned copper bus bar, common neutral link, earth bar, din bar for mounting mcbs (but without mcbs and incomer ) as required . (note : vertical type mcb tpdb is normally usedwhere 3 phase outlets are required.)4 way (4 + 12), double door , electrical 19 supplying and fixing of following ways surface/ recess mounting, vertical type, 415 v, tpn mcb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 a tinned copper bus bar, common neutral link, earth bar, din bar for mounting mcbs (but without mcbs and incomer ) as required . (note : vertical type mcb tpdb is normally usedwhere 3 phase outlets are required.)8 way (4 + 24), double door , electrical 20 supplying and fixing cable end box (loose wire box) suitable for following triple pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with testing and commissioning etc.as required. for 8 way, double door fp mcbdb , electrical 21 supplying and fixing cable end box (loose wire box) suitable for triple pole and neutral, sheet steel, vertical mcb distribution board, 415 v, on surface/ recess, complete with testing and commissioning etc. as required. , 25 a, rccb supplying and fixing following rating, double pole, (single phase and neutral), 240 v, residual current circuit breaker (rccb), having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40 a, rccb supplying and fixing following rating, double pole, (single phase and neutral), 240 v, residual current circuit breaker (rccb), having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , single pole mcb supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , triple pole mcb supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a tp mcb supplying and fixing 40 a rating, 240/415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40a tp mcb , 40a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40a fp mcb , 63a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 100a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , l/f pvc sheathed / xlpe power cable in trench 1 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 95 sq. mm and upto 185 sq. mm , l/f pvc sheathed / xlpe power cable in trench 2 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 185 sq. mm and upto 400 sq. mm , l/f pvc sheathed / xlpe power cable over cable tray above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm ms flat clamp) , s/m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 1 3.5c x 185 sqmm, aluminium conductor cable a2xfy , s/m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 2 3.5c x 150 sqmm, aluminium conductor cable a2xfy , s/m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 3 4c x 35 sqmm aluminium conductor cable a2xfy , cable tray 1 supplying and installing following size of perforated hot dipped galvanised iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 100 mm width x 50 mm depth x 1.6 mm thickness , cable tray 2 supplying and installing following size of perforated hot dipped galvanised iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 300 mm width x 50 mm depth x 1.6 mm thickness , cable tray 3 supplying and installing following size of perforated hot dipped galvanised iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 600 mm width x 62.5 mm depth x 2.0 mm thickness , cable tray “bends” 1 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.100 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 2 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.300 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 3 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.600 mm width x 62.5 mm depth x 2.0 mm thickness , mv cable 1 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring (round (w) or flat (f) as mentioned) and with all components as mentioned , specifications, complete as required.3.5c x 185 sqmm, aluminium conductor cable a2xfy , mv cable 2 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring (round (w) or flat (f) as mentioned) and with all components as mentioned , specifications, complete as required.3.5c x 150 sqmm, aluminium conductor cable a2xfy , mv cable 3 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring (round (w) or flat (f) as mentioned) and with all components as mentioned , specifications, complete as required. 4c x 35 sqmm aluminium conductor cable a2xfy , earthing 1 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. , earthing 2 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. , earthing 3 earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. , earthing 4 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. , earthing 5 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , earthing 6 providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required. , earthing 7 providing and fixing 25 mm x 5 mm g.i. strip in 40 mm dia g.i. pipe from earth electrode including connection with g.i. nut, bolt, spring, washer excavation and re filling etc. as required. , earthing 8 providing and fixing 25 mm x 5 mm copper strip in 40 mm dia g.i. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re filling etc. as required. , earthing 9 providing and fixing earth bus of 50 mm x 5 mm copper strip on surface for connections etc. as required. , earthing 10 providing and fixing earth bus of 50 mm x 5 mm gi strip on surface for connections etc. as required. , fiting & fixtures 1 supply and installation of regular/standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18/22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall/ ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made (2ft) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm/w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply) with output short circuit protection, surge protection.can be fixed directly into the wall/ ceiling , fiting & fixtures 4 supplying and fixing recess mounted 12 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 6 supply, installation, testing and commissioning of 400 mm sweep, 65w,blade material aluminium blades ,speed & oscillation 3 speed, pull cord for speed and oscillation.air delivery minimum 72 m³/min,speed minimun 1350 revolution per minute.suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong/grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm/w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver (smps based constant current supply) with output short circuit protection, surge protection & other reliability test. , fiting & fixtures 8 supplying installation testing & commissioning ofb22 based 9w led 3 star bulb with 850 lumen, 6k color temperature including holder. , fiting & fixtures 9 supplying installation testing & commissioning of black painted extruded aluminium housing. green / red led’s mounted inside the housing. laser engraved signage matter on single / double acrylic sheet fixed on one side suitable for wall / ceiling / suspension type single / double sided display. in double sided version black paper is inserted. ni cd battery back up to 2 hrs. (charged up to 8 10 hrs).mounting strings provided for pendent mounting operating voltage 150 280v ac ambient operating temperature. – 0 to 450c ingress protection – ip42.including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required.220208 besl 03 led ssd wbb green 240 3 8wor220209 besl 03 led ssd wbb red 240 3 8wor220210 besl 03 led dsd wbb green 240 3 8wor220211 besl 03 led dsd wbb red 240 3 8w , fiting & fixtures 10 supply, installation, testing and commissioning of 600 mm sweep, bee 5 star rated, ceiling fan with brush less direct current (bldc) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (cmm/w) minimum 6.85, air delivery minimum 135cmm, 350 rpm (tolerance as per is : 374 2019), thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. , civil & misc works1 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. , civil & misc works2 providing and fixing h.t. danger notice plate of 250 mm x 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. , civil & misc works3 supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) of size 60 cm x 60 cm at the bottom and 50 cm x 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. , civil & misc works4 supplying and fixing cable route marker with 10 cm x 10 cm x 5 mm thick g.i. plate with inscription there on, bolted /welded to 35 mm x 35 mm x 6 mm angle iron, 60 cm long and fixing the same in ground as required. , civil & misc works5 providing & fixing in position 1000 mm wide , electrical insulating rubber mats as per is 15652:2006, 2 mm thick, suitable up to 1.1 kv , fire retardant, no effect of acids, alkalis and transformer oils, moisture proof, high tensile strengthandtexture finish / cloth impression (anti slip , marking on top) , civil & misc works6 supply & fixing shock treatment chart duly mounted on a wooden frame with 5 mm thick glass as required ( approx front area 1.20 sq metre ) , 20 kvaups supplying, installation, testing and commissioningof online double conversion fully microprocessor based ,indoor type, compact ups system of following rating with igbt based pwm technology to achieve thd < 3% and input power factor of greater than 0.95 at 50% loading,suitable for three phase ac input voltage 380 v to 440 v, 50 hz +3% / 3 % and three phase ac output voltage 415 ± 1% volts & frequency 50 ± 0.5 hz , inbuilt isolation transformer, necessary vrla batteries of suitable size having 30 minutes back up time , mounting rack including and suitable size connecting cable (for ups to battery and battery to battery), static and maintenance bypass switch, snmp card for rs232/ ethernet ip computability for operation and monitoring etc. with all components as mentioned , specifications,complete as required.note : concerning vendor needs to furnish the battery sizing calculations at the time of ga approval and battery size has to be as per the approved ga drawing. , external lighting 1 supply and erection of 4 metre height hot dip galvanized octagonal street light pole with following arm with top dia 70 mm and bottom dia a/f 130 mm, made of 3 mm thick sheet along with base plate of size 220 x 220 x 12 mm , small door opening for junction box mounting with mcb & connector, cement concrete of 1:3:6 including excavation, refilling and suitable size foundation bolts with template and all complete jobas required. (but without pole collar) single arm , external lighting 2 supplying and fixing 40/45 watt led type street light with die cast aluminium housing for ingress protection of ip65 and complete with all accessories etc, onpole/building including connection with fr pvc insulated copper conductor cable and earthing the body etc. as required. , transformer supplying, installation testing and commissioning of following rating, distribution transformer, suitable for 3 phase, 50hz, ac supply,dyn 11 vector group,core made of good quality crgo, windings made of double wound copper with approved danger and arc flash signages and with all components as mentioned , specifications and sld and complete as required. power rating 250 kva , 11 kv ht dp structure / ht cable 1 supplying 11kv (earthed) grade, xlpe insulated, heavy duty frls type, armoured cables suitable for 11kv, 50hz, ac system with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel flat armouring and with all components as mentioned in boq, specifications and sld, complete as required.3 core x 240 sq. mm , 11 kv ht dp structure / ht cable 2 supply, installation, testing and commissioning of 11 kv dp structure as per cei & hpseb norms & comprising of the following, but not limited to it for completion of worksfor the followingrsj pole of 9.15 mt length of size 175 x 90 mm complete with suitable m.s. base plate welded at bottombase plate 2 nos. , indoor cable end termination 2 supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, xlpe aluminium conductor cable of 11 kv grade as required. 300 sq. mm , outdoor cable end termination supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, xlpe aluminium conductor cable of 11 kv grade as required. 300 sq. mm , main lt panel main lt panel (refer sld for detail)supply, installation, testing and commissioning of indoor floor mounted/ wall mounted, ip42(indoor) and ip55(outdoor), factory built, modular, sectionalised, compartmentalized, extendable type lt cubicle panel of suitable size suitable for operation on 433/415 volts, 50 hz ac 3 phase 4 wire supply system fabricated from crca sheet steel of 2mm thick for , apfc panel apfc panel (200 kvar) outoor type (refer sld for detail) , ip based cctv system 1 sitc of 2 megapixel @ 25fps, h.265 ip bullet camera,1/2.9 cmos with 2.8~12mm varifocal lens, 0 lux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d/n, 3d dnr, roi coding, poe,onvif,ip66 etc. complete as required. , cctv 2 sitc of 2 megapixel @ 25fps, h.265 ip dome camera,1/2.9 cmos with 3.6 fixed mm 0 lux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d/n, 3d dnr, roi coding, poe,onvif,ip66 etc. complete as required. , cctv 4 sitc of 32ch 4k ivr ,h.265/h.264 • 1080p real time • 4k display • dual lan • 8x hdd • raid •web plugin free h.265/h.264 compression technology 4k display for clear monitoring up to 1080p 16ch decoding ability smart search ii smart vca event searchsupport raid 0, 1, 5 supported to prevent from recording data loss browsers supported: ie , smart functions : target count, electric fence, face detection, humaniod detection,retrograde detection, leave position detectio output, local & network backup etc. complete as required. , cctv 5 sitc of harddiskdrive8tb,24/7surveillance category only complete etc as required.etc.all complete , cctv 6 sitc of 55 led narrow bazel for monitoring for nvr server etc. all complete. , cctv 7 sitc of rj 45 outlets near the cameras etc. all complete. etc. all complete. , cctv 8 sitc of cat 6 patch cords 1 meter high quality four pair twisted stranded cable terminated with rj45 modular plugs at both the ends. , integrated it and epabx system sitcof cat 6 48 port jack panel for data as per given specification etc. all complete. , epabx system 2 sitcof cat 6 48 port jack panel for voice as per given specification etc. all complete. , epabx system 3 sitc of lszh cat 6 speed unshielded twisted pair computer cable with 23 awg solid copper conductors in existing concealed/surface conduits/raceways complete 305 mtr. roll as per specification etc. all complete. , epabx system 4 sitc of cat6 io, face plate, wall box combo2 port etc. all complete. , epabx system 5 sitcof cat 6 mounting cords 7 feet for data as per given specification etc. all complete. , epabx system 6 sitcof cat 6 patch cords 4 feet for telephone as per given specification etc. all complete. , epabx system 7 sitc of 24 port l2 managed 10/100/1000 mbps non poe switch with 4 sfp port , for data pointsrack mountable etc. all complete. , epabx system 8 sitc of 24 port l2 managed poe 10/100/1000 mbps switch with 4 sfp port , for cctv rack mountable etc. all complete. , epabx system 9 sitc of 24 port smart managed non poe with 4 sfp port rack mountable etc. all complete. , epabx system 10 sitc of 15 u mountingrack with ventilation, sliding shelves, power strips, etc. all complete. , epabx system 11 sitc of ip pbx for with 8 trunk 1 pri& 8 digital and 32 analog extension expendble upto 64 extesionsy etc all complete. , epabx system 12 25 pair riser cable , epabx system 13 mdf box25 pair with 20 pairkrone module , epabx system 14 supply, installation, testing & commissioning of analog phone with speaker , small display etc. all complete. , epabx system 15 client workstation supply, installation, testing & commissioning of client workstation as per following specifications:intel core i5 7700k, 4.2ghz, os genuine microsoft microsoft® windows 10 enterprise 64 bit, ram 16gb, memory 500 gbssd +1tb hdd 7200 rpm class graphic card in built processor graphics (gpu):intel® hd graphics 630 and geforce gtx 970 4gb pcie x 16 lp supporting 2/4 monitors., two(2) pci express expansion slots 2/4 usb, 3.0 serial, and 2 hdmi/vga adaptor, cd/dvd rom.; usb keyboard and mouse, ups, associated cables etc. and other required software to control nvr in control room including centralized video management software as per the requirement of the successful operation of the surveillance system complete as required in accordance with laid specification or upto the satisfaction of engineer in charge. , signage 1 providing & fixing of building direction signage mounted on pole, with pole of 100x100mm shs (square hollow section) of height of 5600mm, and sign size of 900x1050, sign made of aluminiu c section of 60mm with internal framing to support the frame in ms tubes hollow section, frame work duly painted with anti rust coatings, with facia of 3mm thick exterior grade aluminium composite panel, cladded with uv cured digital printed retroreflective sheet of 3m make, and back panel of 3mm exterior grade acp, all pipes to be painted in approved color. cost shall includecost towards installation, including excuvation and filling up with specified pcc and fixing of foundation bolts as specified, also it shall include the designing charges.all complete as per direction by engineer in charge. , signage 2 providing & fixing of prohibition sign silk screen printed of approved colors, on acp of exterior grade, of size 300x300mm, all fixtures in stainless steel as per design, it shall include the designing charges .all complete as per direction by engineer in charge. , signage 3 providing & fixing traffic regulatory parking signage mounted on pole, with pole of 50x50mm shs (square hollow section) of height of 300mm, and sign size of 750x750, sign made of aluminium sheet of 3 mm thickness with aluminium supported profile to the frame of ms tube hollow section, aluminium sheet to be cladded with uv printed retroreflective sheet of 3m make frame work duly painted with anti rust coatings., all pipe to be painted in apppproved color. cost shall include cost towards installation, including excuvation and filling up with specified pcc and fixing of foundation bolts as specified, also it shall include the designing charges.all complete as per direction by engineer in charge. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , 2 tr air conditioning 1 split ac (inverter model): supply, installation, testing, commissioning of split type wall mounted air conditioning units of following capacity including inddor, outdoor unit fitted with inverter based rotary compressor fitted with rotary compressor, copper condensor and first charge refrigent r410a/ eco friendly green gas only, all complete including all electrical connections to the electrical power supply system of the building, includingbut not limited to supply of all electrical plugs, etc.,as necessary,lengthening of all electrical wires of ac units ( both indoor and outdoor), drain pipe andincluding suitable voltage stabilisers, etc. so as to place them in a concealed manner in the desired position. the copper pipes and electrical cables shall be concealed in approved manner and neatly run in straight lines in a workman like manner with proper supports. complete supply and installation of split2 tr star rating 3 star , refrigerant piping 1 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work (19mm / 13 mm thick) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 25 mm od, wall thickness >= 1.2 mm (insulation 19 mm thick) , refrigerant piping 2 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work (19mm / 13 mm thick) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 19.1 mm od, wall thickness >= 1.0 mm (insulation 13 mm thick) , refrigerant piping 3 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work (19mm / 13 mm thick) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 15.9 mm od, wall thickness >= 0.8 mm (insulation 13 mm thick) , refrigerant piping 4 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work (19mm / 13 mm thick) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 9.5 mm od, wall thickness >= 0.8 mm (insulation 13 mm thick) , drain piping 1 providing and fixing of cpvc 6 kg/cm2 drainpiping complete with fittings, supports, 6 mm thick closed cell elastomeric insulation as per specifications and drawings. 20 mm , drain piping 2 providing and fixing of cpvc 6 kg/cm2 drainpiping complete with fittings, supports, 6 mm thick closed cell elastomeric insulation as per specifications and drawings. 32 mm , main oxygen manifold supply, installation, testing and commissioning of following gas manifold system (excluding cylinders). the manifold is configured for designed numbers of cylinders and is suitable to withstand a pressure of 145 kg/cm2, along withhigh pressure copper annealed tail pipes with end brass adapter suitable for cylinders and manifold. top frame comprising of high pressure copper pipes of size 1/2” nb x 15swg with high pressure brass fittings made of high tensile brass and connections through nonreturn valves, the design of middle and bottomframes is provided to fit both round and flat bottom cylinders safely. the manifold is tested (hydraulically) at 3500 psig. (it should be ce and iso 13485 certified) mani fold oxygen manifold 4 + 4 cylinder banks complete with nrv, middle frame, bottom frame with ce marked, , emergency manifold emergency oxygen manifold 01 + 01 cylinder emergency manifold with complete regulator, nrv, middle frame & bottom frame, , control panelfor oxygen fully automatic three port control panel for oxygen supply, installation, testing and commissioning of automatic manifold control panel would provide a duty or standby gas supply from two cylinder banks with automaticchangeover the manifold indicates local status and has a remote indicator facility. automaticmanifold control panel would be designed to supply the mgps with a constant pressure supply via a control panel form two equal banks of cylinders and the changeover from the , emergency manifold line regulator emergency manifold line regulator supply, installation, testing and commissioning of emergency manifold line regulator i n p u t p r e s s u r e 1 5 0 k g / c m 2 working pressure 4 kg/cm2 it should be ce and iso 13485 certified.oxygen input pressure 150 kg/cm2 working pressure 4 kg/cm2capacity : 1500 lpm , cylinderconnectingpipe (pig tail) supply, installation, testing and commissioning of cylinder connecting pipe (pig tail) made up of flexible ss hose with safety cord 5/8 inch bsp gland nut and one side 1/2 inch bsp internal threads having one meter length.(oxygen 24 , n2o 10,co2 4) , backpressurecompensated[bpc]oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [bpc] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l/m on an expanded lower scale forprecision setting at low flow and 5 15 l/m for general use. the humidifier bottle should be made up of unbreakable polycarbonate/ polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin /bsstd gas outlet front loaded din /bs std:supply, installation, testing and commissioning of din/british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din/british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din/bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din/british standard quick connect oxygen adapter(safety probe) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve, supply, installation, testing and commissioning of the ball valves [for dividing the pipelines into various zones for the case of maintenance] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [either fully open or fully closed]. it should be ce and iso 13485 certified.42mm , isolation valve 2 supply, installation, testing and commissioning of the ball valves [for dividing the pipelines into various zones for the case of maintenance] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [either fully open or fully closed]. it should be ce and iso 13485 certified 28mm , isolation valve 3 supply, installation, testing and commissioning of the ball valves [for dividing the pipelines into various zones for the case of maintenance] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [either fully open or fully closed]. it should be ce and iso 13485 certified 22mm , isolation valve 4 supply, installation, testing and commissioning of the ball valves [for dividing the pipelines into various zones for the case of maintenance] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [either fully open or fully closed]. it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [for dividing the pipelines into various zones for the case of maintenance] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [either fully open or fully closed]. it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline (in mtrs.) as per en 13348,12 mm (od) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline (in mtrs.) as per en 13348,15 mm (od) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline (in mtrs.) as per en 13348,22 mm (od) x 0.9 mm thickness , pipeline 4 medical grade copper pipeline (in mtrs.) as per en 13348,28 mm (od) x 0.9 mm thickness , pipeline 5 medical grade copper pipeline (in mtrs.) as per en 13348,42 mm (od) x 1.2 mm thickness , hospital sheet patient bedtype iii with mattress overall sizes: (l)2268 mm x ( w)922 mm x (h) 610 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crca , paediatric bed with mattress paediatric bed of overall sizes in mm: 1500 (l) x 850 (w) x 1210 (h)flat single section bed with grille frame on 4 sides.suitable for children up to 12 years.drop down grill frame on both sides for protection of the patient.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board/leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral white , bed side locker type i over all dimension :402mmlx422mm wx840mm ht .locker should have one cabinet and one drawer unit .both provided with cam lock .there should be gap between drawer and unit to keep general items for frequesnt use castors are provided for easy handling .drawer made up of crca sheet 1 mm thick and has ball slide for easy operation .top ss 304 sheet 0.8 mm thick castors 50 mmdia ,hamdle abs ..powder coating of epoxy polyester , medicinetrolleytype i overall size902mm(l)x532mm(w)x915mm(h).top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg/shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm,seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , strecher on trolley type i 2005mm(l)x666mm(w)x827mm(h).the trolley should be made of 31.75 and 25.4 mm dia 1.6 mm thick erw tube.holder for stretcher should be made up of mild steel.castor should be of 200 mm dia , diagonal locking castor.stretcher should be made up oferw tubeof dia 25.4 mm and thickness 1.6 mm.top sheet should be made of crca sheetof thickness 1.2 mm with contour shape to accommodate patient.iv pole holder should be made ofms .maximum safe work load should be 135 kg.to ensure qood quality welding co2 argonprocess should be adhered to.all metal componentsshould be pre treated with zinc phosphating in 9 tank porcess and then powder coated with anti microbialepoxy polyster powder coating.goods should be supplied in knocked down construction to reduce carbon emission. performance test :proof loading test , cycle tests , impact test, salt spray test, castor break test,the manufacturer should compilant with iso 9001, 14001, 13485, ohsas 1800 and ce certification. , doctor desk type x s/f/f executive table main desk should be of dimesion : 1350w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. side panels : (black) made form 18mm thick plt with pvc lipping.modesty panel : made form 18mm thick plt with pvc lipping. bigger upper panel in black and smaller lower panel in white cedar. made from 18mm thick plt with pvc lipping. mobile pedestal : one box and one filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , chair type iii s/f/f executive chair1) seat/back assembly: the seat and back are made up of 1.2 cm. thick hot pressed plywood, upholstered withfabric upholstery covers and moulded polyurethane foam. the back foam is designed with contoured lumbar support for extra comfort. the seat has extra thick foam on front edge to give comfort to popliteal area.high back size : 47.5 cm (w) x 69.5 cm (h)seat size : 47.0 cm. (w) x 48.0 cm. (d) 2) polyurethane foam: the polyurethane foam is moulded with density = 45 +/ 2 kg/m 3and hardness = 20 +/ 2at 25% compression. 3) armrests: the one piece armrests are injection moulded from black co polymer polypropylene. 4) center tilt synchro mechanism : the mechanism is designed with the following features:· 360 revolving type. · upright position locking. · tilt tension adjustment.· seat/back tilting ratio of 1:3 (60 seat tilt/180 back tilt). 5) pneumatic height adjustment : the pneumatic height adjustment has anadjustment stroke of 12.0 cm. 6) telescopic bellow assembly : the bellow is 3 piece telescopic type and injection moulded in black polypropylene. 7) pedestal assembly : the pedestal is injection moulded in black 30% glass filled nylonand fitted with 5 nos. twin wheel castors. the pedestal is 66.0cm pitch center dia. (76.0 cm with castors.) 8) twin wheel castors : the twin wheel castors are injection moulded in black nylon. , staff chair type i chair of over all size: 58.0cm (w) x 56.5cm (d) x 87.5cm (h) & 48.0cm (sh)seat/back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm (w) x 27.0cm (h).*seat size: 46.0cm (w) x 40.0cm (d).armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. (1”) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. (1”) x 14bg. thick m.s. e.r.w. tube and powder coated. , visiter chair type v s/f/f visitor chair1) seat/back assembly: the seat and back are made up of 1.2 cm. thick hot pressed plywood, upholstered with fabric upholstery covers and moulded polyurethane foam. the back foam is designed with contoured lumbar support for extra comfort. the seat has extra thick foam on front edge to give comfort to popliteal area. mid back size : 47.5 cm. (w) x 58.0cm. (h)seat size : 47.0 cm. (w) x 48.0 cm. (d) 2) polyurethane foam: the polyurethane foam is moulded with density = 45 +/ 2 kg/m 3and hardness = 20 +/ 2at 25% compression. 3) armrests: the one piece armrests are injection moulded from black co polymer polypropylene. 4) tubular frame : the powder coated tubular frame is cantilever type & made of dia 25.4mm x 2mm thk m.s. er.w. tube. , wheel chair type i (l) 790 x (w) 600 x (h) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm (l) x 517 mm ( w) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck .3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement.mx load bearing capacity should be 10 kg. , instrument cabinet type i overall dimensions of 900mmwx 1990mmhx450mmd and should have transparent doors and sides with steel frame work. transparent portion of this cupboard should be made of acrylic of 4mm thick. this cabinet should have 5 adjustable acrylic shelves each of 6 mm thickness. three way lock should be provided of 6 levers. in the front door there should be 4 acrylic sheets and 2 each on both the sides. metal used should be of crca and powder coated for finish. to be provided with rubber shoes to prevent direct contact of cabinet and floor. , hospital curtain tracks & i.v. tree system supply installation testing & commissioning of cubical tracks system made of powder coated aluminium alloy,stain free polyster fabric ,water repellent curtains ,smooth movement ,non sticking runnner with stainless steel hooks made from mirror finish stainless steel ,adjustable height with all accessories. total quantity : 1...

Bihar Medical Service And Infrastructure Corporation Ltd - Bihar

29776823 bids are invited for pile boring, providing and installation bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using direct mud circulation (dmc) or bailer and chisel technique by tripod and mechanical winch machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap).450mm dia piles (inclusive of carriage) , pcc providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 (1 cement : 3 coarse sand (zone iii) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) (inclusive of carriage) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland /portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. (inclusive of carriage) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 (1 cement : 4 coarse sand) (inclusive of carriage) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.(inclusive of carriage) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , reinforment steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory/workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone iii) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber/ neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. (glazing, paneling and dash fasteners to be paid for separately) :powder coated aluminium (minimum thickness of powder coating 50 micron) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . (cost of aluminium snap beading shall be paid in basic item):with float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) , upvc door providing and fixing of factory made upvc white colour casement door, upvc multichambered extruted frame, sash and mullion profile. frame duly reinforced with 1.2mm gi section box tpe chamber and sash with 1.5mm thick gi section (± 0.2mm) based on wind load calculations (shape and size according to upvc profiles), appropiate dimentions of upvc extruded glazing bead, epdm gasket (k/o type), seperate drainage system, ss34 grade friction hinges 2d/3d plate hinges, zinc alloy (white powder coated) casement handle, gi fastener 8x100 mm size for fixing frame to finish wall, plastic packer and caps and necessary steel screws etc.profile of frame and sash shall be metered cut and fusion welded at all corners, mullion shall be also fusion welded/joined mechanically including drilling of holes for fixing hardware and drainage of water etc. after fixing of frames , gap between frame and adjascent wall shall be filled with pu foaam / backer rod required size and the approved quantity. after that sealed with weather proof silicon sealant at both side, all complete as per approved drawing and direction of eic , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 (part i) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised (anodic coating not less than grade ac 10 as per is : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , soling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e/l, , tile 1 providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge :flamed finish granite stone slab jet black, cherry red, elitebrown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance (rh) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w/m k, fire performance as per (bs 476 pt 6 &7)in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mmwith 16 mm thick beveled tegular mineral fibre antimicrobial false ceiling tile confirming to iso 5 (class 100) specifications , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized (az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975. the wind load shall be as per provisions of is 875 (part iii). lgsfs frame shall be designed as per is: 801 using commercially available software such as frame cad pro 11.7/ staad pro v8i/ architekv2.5.16/ revit architecture 2011 or equivalent. proper usage of connection accessories like heavy duty tension ties, light duty hold ons, twist straps (to connect truss with wall frames), strong tie, tie rod, h brackets, boxing sections, l shaped angles for better structural stability. the framing section shall be cold form c type having minimum web depth 89 mm x 39mm flange x 11mm lip in required length as per structural design requirement duly punched with dimple/ slot at required locations as per approved drawings. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c/c of approved make. , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c/c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish.(cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by engineer in charge) 0.50 mm +/ 5% total coated thickness (tct) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal/vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm +/ 5% total coated thickness (tct) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling/ self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain (500 600mm). , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm +/ 5% total coated thickness (tct) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling/ self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness (tct), zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling/ self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings/ aprons. (upto 600 mm) , under deck insulation providing and fixing thermal insulation of ceiling (under deck insulation) with resin bonded rockwool conforming to is: 8183,density 48 kg/ m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg/m3,50 mm thick,wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , face panel providing and fixing in all exterior face panels breathable vapour barrier underneath the cementfiber board as per national building code 2009 complete as per direction of engineer in charge. , lap siding supplying and installation of moisture resistant/fire resistantlap siding 8 mm thick and width as per standard sizes made ofiber cement board with embossed decorative finish to give pleasing exterior fixed horizontally with staggered joints including minimum over lapof 32 mm external cement fibre boardconforming to is 14862:2000 offixed with self drilling / taping screws/fastners of approved make. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1 new work (two or more coats) over and including water tinnable priming coat with cement primer , ex. paint finishing walls with textured exterior paint of required shade : new work (two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/ 10 sqm sqm , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel 2 steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , road providing and laying c.c. pavement of mix m 25 with ready mixed concrete from batching plant. the ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc.complete as per specifications and directions of engineer in charge. (the panel shuttering work shall be paid for separately). (note: cement content considered in this item is @ 330 kg/cum. excess/less cement used as per design mix is payable/ recoverableseparately). , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 1 providing and fixing salem stainless steel a isi 304 (18/8) kitchen sink as per is: 13983 with ci brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required.kitchen sink with drain board 510x1040mm bowl depth 200mm. , phe 2 providing and fixing salem stainless steel a isi 304 (18/8) kitchen sink as per is: 13983 with ci brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required.sink without drain board 610x510 mm bowl depth 200mm. , phe 3 providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing:rectangular shape 453x357 mm , phe 4 providing and fixing toilet paper holder:c.p. brass , phe 5 providing and fixing water closet squatting pan (indian type w.c.pan) with 100 mm sand cast iron p or s trap, 10 litre low fixturescomplete, including cutting and making good the walls andlevel whitep.v.c. flushing cistern, including flush pipe, with manually controlleddevice (handle lever) conforming to is : 7231, with all fittings andfloors wherever required :white vitreous china orissa pattern w.c. pan of size580x440 mm with integral type foot rests , phe 6 providing and fixing white vitreous china pedestal type water closet (european type w.c. pan) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 7 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 8 providing and fixing cp brass 32mm size bottle trap of approved quality & make and as per the direction of engineer in charge..(sink & urinal) , phe 9 providing & fixingptmt towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealedfittings arrangement of approved quality and colour weighing not less than 88 gms , phe 10 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 11 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 12 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a) 15 mm nominal bore.15 mm nominal bore , phe 13 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size660x460 mm with a pair of 15 mm c.p. brass pillar tapswith elbow operated levers , phe 14 providing & fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. , phe 15 providing and fixing white vitreous china laboratory sink with c.i. brackets, c.p. brass chain with rubber plug, 40 mm c.p brass waste and 40mm c.p. brass trap with necessary c.p. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required :size 600x450x200 mm , phe 16 providing and fixing cp brass single lever telephonic wall mixer of quality & make as approved by engineer in charge . a) 15 mm nominal dia. , phe 17 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 18 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 19 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. , phe 20 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. (internal work) 40 mm dia, nominal bore , phe 21 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. (internal work)50 mm dia, nominal bore , phe 22 two or more coats on new work over an under coat ofsuitable shade with ordinary paint of approved brand andmanufacturetwo more coast on new work , phe 23 p/f m.s. cap 100 mm dia , phe 24 providing and fixing, upvcpipes 6 kg/cm2(is: 4985) including all fittings (plain or door) e.g. bends, junction, offsets, access pieces, jointing with rubber ring/solvent cement joints includingrequired suports,cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 25 providing and fixing, upvcpipes 6 kg/cm2(is: 4985) including all fittings (plain or door) e.g. bends, junction, offsets, access pieces, jointing with rubber ring/solvent cement joints includingrequired suports,cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 26 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. (i)single socketed pipes.110 mm diameter , phe 27 providing, fixing on wall face unplasticised pvc moulded fittings /accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 28 providing, fixing on wall face unplasticised pvc moulded fittings /accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings /accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 30 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4(1cement : 4 coarse sand) and making good the wall etc. complete.110 mm dia , phe 31 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 32 providing and fixing of gun metal gate valve with ci wheel of approved quality (screwed ends)25mm dia, nominal bore , phe 33 providing and fixing of gun metal gate valve with ci wheel of approved quality (screwed ends) 32 mm dia, nominal bore , phe 34 providing and fixing gun metal non return valve of approved quality (pn 1.6)40 nominal bore , phe 35 providing and fixing brass stop cock of approved quality15mm nominal bore , phe 36 butterfly valve (manual) with c i body ss disc, nitrile rubber seal & o ring pn 16 pressure rating for chilled water/hot eater circulation as specified 65 nominal bore , phe 37 butterfly valve (manual) with c i body ss disc, nitrile rubber seal & o ring pn 16 pressure rating for chilled water/hot eater circulation as specified80 nominal bore , phe 38 providing and fixing ball valve (brass) of approved quality, high or low pressure, with plastic floats complete25 mm nominal bore , ex. phe 1 providing and fixing c.i. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (the tail pieces, tapers etc if required will be paid separately) :50 mm dia , ex. phe 2 providing and fixing c.i. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (the tail pieces, tapers etc if required will be paid separately) :80 mm dia , ex. phe 3 providing and fixing c.i. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (the tail pieces, tapers etc if required will be paid separately) :100 mm dia , ex. phe 4 providing & fixing c.i.sluice valve(with cap)complete with bolts,nuts,rubber insertions etc.(the tail pieces if required will be paid separately)100 mm dia.pipe , ex. phe 5 providing & fixing c.i.sluice valve(with cap)complete with bolts,nuts,rubber insertions etc.(the tail pieces if required will be paid separately)150 mm dia.pipe , ex. phe 6 providing 250mm wide brick drain in cement mortar (1:6) with av. 150mm.clear depth and 250mm apron including cost of e/w. involved with 75mmcement concrete (1:4:8) over one brick designation 100 a flat soling inproper grade and slope at the base.the drain duly.plastered in cm. (1:3)with punning over exposed surface all complete as per buildingspecification and direction of e/l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil (hard or soft) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [hard/dense soil] pipes,cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 8 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil (hard or soft) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [hard/dense soil] pipes,cables etc.exceeding 80mm dia. exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class (light duty) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete. (for storm drainage)250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class (light duty) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete. (for storm drainage)300 mm dia rcc pipe , ex. phe 11 providing and laying non pressure np2 class (light duty) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete. (for storm drainage)450 mm dia rcc pipe , ex. phe 12 inside size 120x90 cm and 90 cm deep including c.i. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) :with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 , ex. phe 13 providing and fixing square mouth sw gully trap grade ‘a’ complete ci grating brick masonry chamber with bricks of class designation 75 and water tight ci cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 13.00 kg and frame to be not less than 5 kg. as per standard design.(cover min. 4.5 kg & frame min.2.7 kg )180x150 mm size p type with fps bricks , ex. phe 14 constructing masonry chamber 30x30x50 cm,inside with 75 class designation brick work in cement mortar 1:4 (1 cement:4 coarce sand) for stop cock complete with c.i. surface box 100x100x75mm (inside) with locking arrangement and rcc top slab 1:2:4 mix (1 cement : 2 corase sand: 4 graded stonr aggregate 20mm nominal size) necessary excavation foundation concret 1:5:10 (1 cement:5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortor 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design. , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement: 4 coarse sand) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with channel lid and rcc top slab 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement: 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , ex. phe 16 structual steel work welded in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. , ex. phe 17 making connection of gi distribution branch with gi main of 50 80mm nominal bore by providing and fixing tee, including cutting and threading the pipe etc. complete. , rain water harvesting 1 boring/drilling bore well of required dia for casing/ strainer pipe, bysuitable method prescribed in is:2800(part i ), including collecting sample from different strata , preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90m depth below ground level.300 mm dia , rain water harvesting 2 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing (cm) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150mm nominal size dia , rain water harvesting 3 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well screen(rms) pipes with ribs, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150 mm nominal size dia , rain water harvesting 4 supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 5 supplying, filling, spreading & levelling gravel of size range 5mm to 10mm, in recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 6 supplying, filling, spreading & levelling coarse sand of size range 1.5mm to 2mm, in recharge pit, in required thickness over gravel layer,for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 7 providing and fixing bail plug/ bottom plug of required dia to the bottom of pipe assembly of tube well as per is:2800(part i). 100 mm dia , rain water harvesting 8 making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and s.w. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 , rain water harvesting 9 constructing soak pit 1.20x1.20x1.20 m filled with brickbats including s.w. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. with common burnt clay f.p.s. (non modular) bricks of class designation 7.5 , tubewell 1 boring/drilling bore well of required dia for casing/ strainer pipe, bysuitable method prescribed in is:2800(part i ), including collecting sample from different strata , preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90m depth below ground level.300 mm dia , tubewell 2 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing (cm) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150mm nominal size dia , tubewell 3 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing (cm) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.100mm nominal size dia , tubewell 4 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well screen(rms) pipes with ribs, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.100 mm nominal size dia , tubewell 5 supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , tubewell 6 providing and fixing bail plug/ bottom plug of required dia to the bottom of pipe assembly of tube well as per is:2800(part i). 100 mm dia , submersible pump 35m deep boring with casing and pipe. supply of pipe etc supplying & installation of suitable 2hp submersible pump b.s or k.s.bor equivalent make with finolex cable 1x3x2.5 squmm(upto 50mtr) withflexible conduit 25mm dia, electrical out door pannel with required electrical fitting such as mcb of 0 25amp (havell or indocopp or mds make), volt & ampere meter (ae make), single phase preventer (minilac or vsp 1 make) starter (l&t or bch make) etc of approved make, 40mm hdpe pipe (25 mtr) and all accessories complete as per requirement of site. , water purifier and cooler 1 fitting and fixing single faucet storage type water cooler ( size 461 mm wide x 582 mm deep x 1217 mm height, weight 46 kg) fully stainless body having storage capacity of 40 ltrs, cooling capacity of 40 ltrs./hr. with hermetic type compressor, gas cooled motor equipped with over load protector, condensor for propeller type, thermostat autometically controlled temperature, refrigerent r 22, 230 volt, single phase 50 hertz, maximum current 2.3 amp including plug top and electrical lead wire connection upto 3 metres from the cooler, water inlet and drain out connections complete in all respects of voltas model no 40/40 tushar pss type or similar type of approved make. , water purifier and cooler 2 fitting and fixing water purifier for drinking purpose of capacity 6 litres/min, 5 purification system with reverse osmosis system with ultra ventilated membrane, tds500 to 2000 mgl/ppm, auto shut off with microswitch float manual flush facility, tds reduction 90% having automatic backwash system with filteration unit along with all accessories including plug top and electrical lead wire connection upto 3 metres from the purifier, water inlet and drain out connections complete in all respects similar to aquaguard or similar approved make (model aquasure elegant ro water purifier of size width 360 mm x height 430 mm x depth 235 mm and weight 8.5 kg). , fire extinguisher 1 providing and fixing carbon di oxide type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. capacity 4.5 kg. , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 6.0 kg. , electrical 1 wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm frls pvc insulated copper conductorsingle core cable in surface / recessed steel conduit, withmodular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. group c , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface /recessed steel conduit, 2 way modular switch, modular plate,suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , pvc conduit 1 supplying and fixing of following sizes of medium class 20mmpvc conduit along with accessories in surface/ recessincluding cutting the wall and making good the same incase of recessed conduit as required. , pvc conduit 2 supplying and fixing of following sizes of medium class 32mmpvc conduit along with accessories in surface/ recessincluding cutting the wall and making good the same incase of recessed conduit as required. , pvc conduit 3 supplying and fixing of following sizes of medium class 50mmpvc conduit along with accessories in surface/ recessincluding cutting the wall and making good the same incase of recessed conduit as required. , electrical 4 wiring for light/ power plug with 2x4 sq. mm frls pvcinsulated copper conductor single core cable in surface/recessed steel conduit alongwith 1 no. 4 sq. mm frls pvcinsulated copper conductor single core cable for loop earthingas required. , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 4 4 x 6 sq. mm + 2 x 6 sq. mm earth wire , wiring frls pvc insulated copper conductor 5 4 x 10 sq. mm + 2 x 6 sq. mm earth wire , wiring frls pvc insulated copper conductor 6 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s/f, gi box along with modular base & cover plate 1 1 or 2 module (75mm x 75mm) , s/f, gi box along with modular base & cover plate 2 3 module (100mm x 75mm) , s/f, gi box along with modular base & cover plate 3 4 module (125mmx75mm) , s/f, gi box along with modular base & cover plate 4 6 module (200mm x 75mm) , s/f, gi box along with modular base & cover plate 5 12 module (200mmx150mm) , s/f modular switch/ socket on the existing modular plate 1 5/6 amps switch , s/f modular switch/ socket on the existing modular plate 2 15/16 amp switch , s/f modular switch/ socket on the existing modular plate 3 3 pin 5/6 amp socket outlet , s/f modular switch/ socket on the existing modular plate 4 6 pin 15/16 amp socket outlet , s/f modular switch/ socket on the existing modular plate 5 telephone socket outlet , s/f modular switch/ socket on the existing modular plate 6 tv antenna socket outlet , s/f modular switch/ socket on the existing modular plate 7 bell push , fan regulator on the existing modular plate switch box supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. , call bell/ buzze supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. , electrical 5 supplying & fixing suitable size gi box wih modular plate and cover in front on surface or in recess including providing and fixing 25 a modular socket outlet and 25 a modular sp mcb, “c” curve including connections, painting etc. as required. (for ac/ geyser) , electrical 6 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface/ recessed steel/ pvc conduit as required. , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 9 providing and fixing circular/ hexagonal cast iron or m.s. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick m.s. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ m.s. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. clamp shall be made of 12 mm dia m.s. bar bent to shape as per standard drawing. , 40a fp isolator supplying and fixing following rating, four pole, 415 v, isolator in the existing mcb db complete with connections, testing andcommissioning etc. as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 11 supplying and fixing 20 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. , electrical 12 supplying and fixing 30 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. , electrical 17 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without mcb/rccb/isolator)8 way (4 + 24), double door , electrical 18 supplying and fixing of following ways surface/ recess mounting, vertical type, 415 v, tpn mcb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 a tinned copper bus bar, common neutral link, earth bar, din bar for mounting mcbs (but without mcbs and incomer ) as required . (note : vertical type mcb tpdb is normally usedwhere 3 phase outlets are required.)4 way (4 + 12), double door , electrical 19 supplying and fixing of following ways surface/ recess mounting, vertical type, 415 v, tpn mcb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 a tinned copper bus bar, common neutral link, earth bar, din bar for mounting mcbs (but without mcbs and incomer ) as required . (note : vertical type mcb tpdb is normally usedwhere 3 phase outlets are required.)8 way (4 + 24), double door , electrical 20 supplying and fixing cable end box (loose wire box) suitable for following triple pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface/ recess, complete with testing and commissioning etc.as required. for 8 way, double door fp mcbdb , electrical 21 supplying and fixing cable end box (loose wire box) suitable for triple pole and neutral, sheet steel, vertical mcb distribution board, 415 v, on surface/ recess, complete with testing and commissioning etc. as required. , 25 a, rccb supplying and fixing following rating, double pole, (single phase and neutral), 240 v, residual current circuit breaker (rccb), having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40 a, rccb supplying and fixing following rating, double pole, (single phase and neutral), 240 v, residual current circuit breaker (rccb), having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , single pole mcb supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , triple pole mcb supplying and fixing 5 a to 32 a rating, 240/415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a tp mcb supplying and fixing 40 a rating, 240/415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40a tp mcb , 40a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40a fp mcb , 63a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 100a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , l/f pvc sheathed / xlpe power cable in trench 1 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 95 sq. mm and upto 185 sq. mm , l/f pvc sheathed / xlpe power cable in trench 2 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 185 sq. mm and upto 400 sq. mm , l/f pvc sheathed / xlpe power cable over cable tray above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm ms flat clamp) , s/m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 1 3.5c x 185 sqmm, aluminium conductor cable a2xfy , s/m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 2 3.5c x 150 sqmm, aluminium conductor cable a2xfy , s/m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 3 4c x 35 sqmm aluminium conductor cable a2xfy , cable tray 1 supplying and installing following size of perforated hot dipped galvanised iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 100 mm width x 50 mm depth x 1.6 mm thickness , cable tray 2 supplying and installing following size of perforated hot dipped galvanised iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 300 mm width x 50 mm depth x 1.6 mm thickness , cable tray 3 supplying and installing following size of perforated hot dipped galvanised iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 600 mm width x 62.5 mm depth x 2.0 mm thickness , cable tray “bends” 1 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.100 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 2 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.300 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 3 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.600 mm width x 62.5 mm depth x 2.0 mm thickness , mv cable 1 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring (round (w) or flat (f) as mentioned) and with all components as mentioned , specifications, complete as required.3.5c x 185 sqmm, aluminium conductor cable a2xfy , mv cable 2 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring (round (w) or flat (f) as mentioned) and with all components as mentioned , specifications, complete as required.3.5c x 150 sqmm, aluminium conductor cable a2xfy , mv cable 3 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring (round (w) or flat (f) as mentioned) and with all components as mentioned , specifications, complete as required. 4c x 35 sqmm aluminium conductor cable a2xfy , earthing 1 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. , earthing 2 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. , earthing 3 earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. , earthing 4 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. , earthing 5 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , earthing 6 providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required. , earthing 7 providing and fixing 25 mm x 5 mm g.i. strip in 40 mm dia g.i. pipe from earth electrode including connection with g.i. nut, bolt, spring, washer excavation and re filling etc. as required. , earthing 8 providing and fixing 25 mm x 5 mm copper strip in 40 mm dia g.i. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re filling etc. as required. , earthing 9 providing and fixing earth bus of 50 mm x 5 mm copper strip on surface for connections etc. as required. , earthing 10 providing and fixing earth bus of 50 mm x 5 mm gi strip on surface for connections etc. as required. , fiting & fixtures 1 supply and installation of regular/standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18/22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall/ ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made (2ft) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm/w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply) with output short circuit protection, surge protection.can be fixed directly into the wall/ ceiling , fiting & fixtures 4 supplying and fixing recess mounted 12 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 6 supply, installation, testing and commissioning of 400 mm sweep, 65w,blade material aluminium blades ,speed & oscillation 3 speed, pull cord for speed and oscillation.air delivery minimum 72 m³/min,speed minimun 1350 revolution per minute.suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong/grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm/w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver (smps based constant current supply) with output short circuit protection, surge protection & other reliability test. , fiting & fixtures 8 supplying installation testing & commissioning ofb22 based 9w led 3 star bulb with 850 lumen, 6k color temperature including holder. , fiting & fixtures 9 supplying installation testing & commissioning of black painted extruded aluminium housing. green / red led’s mounted inside the housing. laser engraved signage matter on single / double acrylic sheet fixed on one side suitable for wall / ceiling / suspension type single / double sided display. in double sided version black paper is inserted. ni cd battery back up to 2 hrs. (charged up to 8 10 hrs).mounting strings provided for pendent mounting operating voltage 150 280v ac ambient operating temperature. – 0 to 450c ingress protection – ip42.including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required.220208 besl 03 led ssd wbb green 240 3 8wor220209 besl 03 led ssd wbb red 240 3 8wor220210 besl 03 led dsd wbb green 240 3 8wor220211 besl 03 led dsd wbb red 240 3 8w , fiting & fixtures 10 supply, installation, testing and commissioning of 600 mm sweep, bee 5 star rated, ceiling fan with brush less direct current (bldc) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (cmm/w) minimum 6.85, air delivery minimum 135cmm, 350 rpm (tolerance as per is : 374 2019), thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. , civil & misc works1 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. , civil & misc works2 providing and fixing h.t. danger notice plate of 250 mm x 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. , civil & misc works3 supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) of size 60 cm x 60 cm at the bottom and 50 cm x 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. , civil & misc works4 supplying and fixing cable route marker with 10 cm x 10 cm x 5 mm thick g.i. plate with inscription there on, bolted /welded to 35 mm x 35 mm x 6 mm angle iron, 60 cm long and fixing the same in ground as required. , civil & misc works5 providing & fixing in position 1000 mm wide , electrical insulating rubber mats as per is 15652:2006, 2 mm thick, suitable up to 1.1 kv , fire retardant, no effect of acids, alkalis and transformer oils, moisture proof, high tensile strengthandtexture finish / cloth impression (anti slip , marking on top) , civil & misc works6 supply & fixing shock treatment chart duly mounted on a wooden frame with 5 mm thick glass as required ( approx front area 1.20 sq metre ) , 20 kvaups supplying, installation, testing and commissioningof online double conversion fully microprocessor based ,indoor type, compact ups system of following rating with igbt based pwm technology to achieve thd < 3% and input power factor of greater than 0.95 at 50% loading,suitable for three phase ac input voltage 380 v to 440 v, 50 hz +3% / 3 % and three phase ac output voltage 415 ± 1% volts & frequency 50 ± 0.5 hz , inbuilt isolation transformer, necessary vrla batteries of suitable size having 30 minutes back up time , mounting rack including and suitable size connecting cable (for ups to battery and battery to battery), static and maintenance bypass switch, snmp card for rs232/ ethernet ip computability for operation and monitoring etc. with all components as mentioned , specifications,complete as required.note : concerning vendor needs to furnish the battery sizing calculations at the time of ga approval and battery size has to be as per the approved ga drawing. , external lighting 1 supply and erection of 4 metre height hot dip galvanized octagonal street light pole with following arm with top dia 70 mm and bottom dia a/f 130 mm, made of 3 mm thick sheet along with base plate of size 220 x 220 x 12 mm , small door opening for junction box mounting with mcb & connector, cement concrete of 1:3:6 including excavation, refilling and suitable size foundation bolts with template and all complete jobas required. (but without pole collar) single arm , external lighting 2 supplying and fixing 40/45 watt led type street light with die cast aluminium housing for ingress protection of ip65 and complete with all accessories etc, onpole/building including connection with fr pvc insulated copper conductor cable and earthing the body etc. as required. , transformer supplying, installation testing and commissioning of following rating, distribution transformer, suitable for 3 phase, 50hz, ac supply,dyn 11 vector group,core made of good quality crgo, windings made of double wound copper with approved danger and arc flash signages and with all components as mentioned , specifications and sld and complete as required. power rating 250 kva , 11 kv ht dp structure / ht cable 1 supplying 11kv (earthed) grade, xlpe insulated, heavy duty frls type, armoured cables suitable for 11kv, 50hz, ac system with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel flat armouring and with all components as mentioned in boq, specifications and sld, complete as required.3 core x 240 sq. mm , 11 kv ht dp structure / ht cable 2 supply, installation, testing and commissioning of 11 kv dp structure as per cei & hpseb norms & comprising of the following, but not limited to it for completion of worksfor the followingrsj pole of 9.15 mt length of size 175 x 90 mm complete with suitable m.s. base plate welded at bottombase plate 2 nos. , indoor cable end termination 2 supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, xlpe aluminium conductor cable of 11 kv grade as required. 300 sq. mm , outdoor cable end termination supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, xlpe aluminium conductor cable of 11 kv grade as required. 300 sq. mm , main lt panel main lt panel (refer sld for detail)supply, installation, testing and commissioning of indoor floor mounted/ wall mounted, ip42(indoor) and ip55(outdoor), factory built, modular, sectionalised, compartmentalized, extendable type lt cubicle panel of suitable size suitable for operation on 433/415 volts, 50 hz ac 3 phase 4 wire supply system fabricated from crca sheet steel of 2mm thick for , apfc panel apfc panel (200 kvar) outoor type (refer sld for detail) , ip based cctv system 1 sitc of 2 megapixel @ 25fps, h.265 ip bullet camera,1/2.9 cmos with 2.8~12mm varifocal lens, 0 lux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d/n, 3d dnr, roi coding, poe,onvif,ip66 etc. complete as required. , cctv 2 sitc of 2 megapixel @ 25fps, h.265 ip dome camera,1/2.9 cmos with 3.6 fixed mm 0 lux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d/n, 3d dnr, roi coding, poe,onvif,ip66 etc. complete as required. , cctv 4 sitc of 32ch 4k ivr ,h.265/h.264 • 1080p real time • 4k display • dual lan • 8x hdd • raid •web plugin free h.265/h.264 compression technology 4k display for clear monitoring up to 1080p 16ch decoding ability smart search ii smart vca event searchsupport raid 0, 1, 5 supported to prevent from recording data loss browsers supported: ie , smart functions : target count, electric fence, face detection, humaniod detection,retrograde detection, leave position detectio output, local & network backup etc. complete as required. , cctv 5 sitc of harddiskdrive8tb,24/7surveillance category only complete etc as required.etc.all complete , cctv 6 sitc of 55 led narrow bazel for monitoring for nvr server etc. all complete. , cctv 7 sitc of rj 45 outlets near the cameras etc. all complete. etc. all complete. , cctv 8 sitc of cat 6 patch cords 1 meter high quality four pair twisted stranded cable terminated with rj45 modular plugs at both the ends. , integrated it and epabx system sitcof cat 6 48 port jack panel for data as per given specification etc. all complete. , epabx system 2 sitcof cat 6 48 port jack panel for voice as per given specification etc. all complete. , epabx system 3 sitc of lszh cat 6 speed unshielded twisted pair computer cable with 23 awg solid copper conductors in existing concealed/surface conduits/raceways complete 305 mtr. roll as per specification etc. all complete. , epabx system 4 sitc of cat6 io, face plate, wall box combo2 port etc. all complete. , epabx system 5 sitcof cat 6 mounting cords 7 feet for data as per given specification etc. all complete. , epabx system 6 sitcof cat 6 patch cords 4 feet for telephone as per given specification etc. all complete. , epabx system 7 sitc of 24 port l2 managed 10/100/1000 mbps non poe switch with 4 sfp port , for data pointsrack mountable etc. all complete. , epabx system 8 sitc of 24 port l2 managed poe 10/100/1000 mbps switch with 4 sfp port , for cctv rack mountable etc. all complete. , epabx system 9 sitc of 24 port smart managed non poe with 4 sfp port rack mountable etc. all complete. , epabx system 10 sitc of 15 u mountingrack with ventilation, sliding shelves, power strips, etc. all complete. , epabx system 11 sitc of ip pbx for with 8 trunk 1 pri& 8 digital and 32 analog extension expendble upto 64 extesionsy etc all complete. , epabx system 12 25 pair riser cable , epabx system 13 mdf box25 pair with 20 pairkrone module , epabx system 14 supply, installation, testing & commissioning of analog phone with speaker , small display etc. all complete. , epabx system 15 client workstation supply, installation, testing & commissioning of client workstation as per following specifications:intel core i5 7700k, 4.2ghz, os genuine microsoft microsoft® windows 10 enterprise 64 bit, ram 16gb, memory 500 gbssd +1tb hdd 7200 rpm class graphic card in built processor graphics (gpu):intel® hd graphics 630 and geforce gtx 970 4gb pcie x 16 lp supporting 2/4 monitors., two(2) pci express expansion slots 2/4 usb, 3.0 serial, and 2 hdmi/vga adaptor, cd/dvd rom.; usb keyboard and mouse, ups, associated cables etc. and other required software to control nvr in control room including centralized video management software as per the requirement of the successful operation of the surveillance system complete as required in accordance with laid specification or upto the satisfaction of engineer in charge. , signage 1 providing & fixing of building direction signage mounted on pole, with pole of 100x100mm shs (square hollow section) of height of 5600mm, and sign size of 900x1050, sign made of aluminiu c section of 60mm with internal framing to support the frame in ms tubes hollow section, frame work duly painted with anti rust coatings, with facia of 3mm thick exterior grade aluminium composite panel, cladded with uv cured digital printed retroreflective sheet of 3m make, and back panel of 3mm exterior grade acp, all pipes to be painted in approved color. cost shall includecost towards installation, including excuvation and filling up with specified pcc and fixing of foundation bolts as specified, also it shall include the designing charges.all complete as per direction by engineer in charge. , signage 2 providing & fixing of prohibition sign silk screen printed of approved colors, on acp of exterior grade, of size 300x300mm, all fixtures in stainless steel as per design, it shall include the designing charges .all complete as per direction by engineer in charge. , signage 3 providing & fixing traffic regulatory parking signage mounted on pole, with pole of 50x50mm shs (square hollow section) of height of 300mm, and sign size of 750x750, sign made of aluminium sheet of 3 mm thickness with aluminium supported profile to the frame of ms tube hollow section, aluminium sheet to be cladded with uv printed retroreflective sheet of 3m make frame work duly painted with anti rust coatings., all pipe to be painted in apppproved color. cost shall include cost towards installation, including excuvation and filling up with specified pcc and fixing of foundation bolts as specified, also it shall include the designing charges.all complete as per direction by engineer in charge. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , 2 tr air conditioning 1 split ac (inverter model): supply, installation, testing, commissioning of split type wall mounted air conditioning units of following capacity including inddor, outdoor unit fitted with inverter based rotary compressor fitted with rotary compressor, copper condensor and first charge refrigent r410a/ eco friendly green gas only, all complete including all electrical connections to the electrical power supply system of the building, includingbut not limited to supply of all electrical plugs, etc.,as necessary,lengthening of all electrical wires of ac units ( both indoor and outdoor), drain pipe andincluding suitable voltage stabilisers, etc. so as to place them in a concealed manner in the desired position. the copper pipes and electrical cables shall be concealed in approved manner and neatly run in straight lines in a workman like manner with proper supports. complete supply and installation of split2 tr star rating 3 star , refrigerant piping 1 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work (19mm / 13 mm thick) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 25 mm od, wall thickness >= 1.2 mm (insulation 19 mm thick) , refrigerant piping 2 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work (19mm / 13 mm thick) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 19.1 mm od, wall thickness >= 1.0 mm (insulation 13 mm thick) , refrigerant piping 3 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work (19mm / 13 mm thick) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 15.9 mm od, wall thickness >= 0.8 mm (insulation 13 mm thick) , refrigerant piping 4 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work (19mm / 13 mm thick) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 9.5 mm od, wall thickness >= 0.8 mm (insulation 13 mm thick) , drain piping 1 providing and fixing of cpvc 6 kg/cm2 drainpiping complete with fittings, supports, 6 mm thick closed cell elastomeric insulation as per specifications and drawings. 20 mm , drain piping 2 providing and fixing of cpvc 6 kg/cm2 drainpiping complete with fittings, supports, 6 mm thick closed cell elastomeric insulation as per specifications and drawings. 32 mm , main oxygen manifold supply, installation, testing and commissioning of following gas manifold system (excluding cylinders). the manifold is configured for designed numbers of cylinders and is suitable to withstand a pressure of 145 kg/cm2, along withhigh pressure copper annealed tail pipes with end brass adapter suitable for cylinders and manifold. top frame comprising of high pressure copper pipes of size 1/2” nb x 15swg with high pressure brass fittings made of high tensile brass and connections through nonreturn valves, the design of middle and bottomframes is provided to fit both round and flat bottom cylinders safely. the manifold is tested (hydraulically) at 3500 psig. (it should be ce and iso 13485 certified) mani fold oxygen manifold 4 + 4 cylinder banks complete with nrv, middle frame, bottom frame with ce marked, , emergency manifold emergency oxygen manifold 01 + 01 cylinder emergency manifold with complete regulator, nrv, middle frame & bottom frame, , control panelfor oxygen fully automatic three port control panel for oxygen supply, installation, testing and commissioning of automatic manifold control panel would provide a duty or standby gas supply from two cylinder banks with automaticchangeover the manifold indicates local status and has a remote indicator facility. automaticmanifold control panel would be designed to supply the mgps with a constant pressure supply via a control panel form two equal banks of cylinders and the changeover from the , emergency manifold line regulator emergency manifold line regulator supply, installation, testing and commissioning of emergency manifold line regulator i n p u t p r e s s u r e 1 5 0 k g / c m 2 working pressure 4 kg/cm2 it should be ce and iso 13485 certified.oxygen input pressure 150 kg/cm2 working pressure 4 kg/cm2capacity : 1500 lpm , cylinderconnectingpipe (pig tail) supply, installation, testing and commissioning of cylinder connecting pipe (pig tail) made up of flexible ss hose with safety cord 5/8 inch bsp gland nut and one side 1/2 inch bsp internal threads having one meter length.(oxygen 24 , n2o 10,co2 4) , backpressurecompensated[bpc]oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [bpc] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l/m on an expanded lower scale forprecision setting at low flow and 5 15 l/m for general use. the humidifier bottle should be made up of unbreakable polycarbonate/ polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin /bsstd gas outlet front loaded din /bs std:supply, installation, testing and commissioning of din/british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din/british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din/bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din/british standard quick connect oxygen adapter(safety probe) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve, supply, installation, testing and commissioning of the ball valves [for dividing the pipelines into various zones for the case of maintenance] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [either fully open or fully closed]. it should be ce and iso 13485 certified.42mm , isolation valve 2 supply, installation, testing and commissioning of the ball valves [for dividing the pipelines into various zones for the case of maintenance] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [either fully open or fully closed]. it should be ce and iso 13485 certified 28mm , isolation valve 3 supply, installation, testing and commissioning of the ball valves [for dividing the pipelines into various zones for the case of maintenance] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [either fully open or fully closed]. it should be ce and iso 13485 certified 22mm , isolation valve 4 supply, installation, testing and commissioning of the ball valves [for dividing the pipelines into various zones for the case of maintenance] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [either fully open or fully closed]. it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [for dividing the pipelines into various zones for the case of maintenance] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [either fully open or fully closed]. it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline (in mtrs.) as per en 13348,12 mm (od) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline (in mtrs.) as per en 13348,15 mm (od) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline (in mtrs.) as per en 13348,22 mm (od) x 0.9 mm thickness , pipeline 4 medical grade copper pipeline (in mtrs.) as per en 13348,28 mm (od) x 0.9 mm thickness , pipeline 5 medical grade copper pipeline (in mtrs.) as per en 13348,42 mm (od) x 1.2 mm thickness , hospital sheet patient bedtype iii with mattress overall sizes: (l)2268 mm x ( w)922 mm x (h) 610 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crca , paediatric bed with mattress paediatric bed of overall sizes in mm: 1500 (l) x 850 (w) x 1210 (h)flat single section bed with grille frame on 4 sides.suitable for children up to 12 years.drop down grill frame on both sides for protection of the patient.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board/leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral white , bed side locker type i over all dimension :402mmlx422mm wx840mm ht .locker should have one cabinet and one drawer unit .both provided with cam lock .there should be gap between drawer and unit to keep general items for frequesnt use castors are provided for easy handling .drawer made up of crca sheet 1 mm thick and has ball slide for easy operation .top ss 304 sheet 0.8 mm thick castors 50 mmdia ,hamdle abs ..powder coating of epoxy polyester , medicinetrolleytype i overall size902mm(l)x532mm(w)x915mm(h).top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg/shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm,seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , strecher on trolley type i 2005mm(l)x666mm(w)x827mm(h).the trolley should be made of 31.75 and 25.4 mm dia 1.6 mm thick erw tube.holder for stretcher should be made up of mild steel.castor should be of 200 mm dia , diagonal locking castor.stretcher should be made up oferw tubeof dia 25.4 mm and thickness 1.6 mm.top sheet should be made of crca sheetof thickness 1.2 mm with contour shape to accommodate patient.iv pole holder should be made ofms .maximum safe work load should be 135 kg.to ensure qood quality welding co2 argonprocess should be adhered to.all metal componentsshould be pre treated with zinc phosphating in 9 tank porcess and then powder coated with anti microbialepoxy polyster powder coating.goods should be supplied in knocked down construction to reduce carbon emission. performance test :proof loading test , cycle tests , impact test, salt spray test, castor break test,the manufacturer should compilant with iso 9001, 14001, 13485, ohsas 1800 and ce certification. , doctor desk type x s/f/f executive table main desk should be of dimesion : 1350w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. side panels : (black) made form 18mm thick plt with pvc lipping.modesty panel : made form 18mm thick plt with pvc lipping. bigger upper panel in black and smaller lower panel in white cedar. made from 18mm thick plt with pvc lipping. mobile pedestal : one box and one filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , chair type iii s/f/f executive chair1) seat/back assembly: the seat and back are made up of 1.2 cm. thick hot pressed plywood, upholstered withfabric upholstery covers and moulded polyurethane foam. the back foam is designed with contoured lumbar support for extra comfort. the seat has extra thick foam on front edge to give comfort to popliteal area.high back size : 47.5 cm (w) x 69.5 cm (h)seat size : 47.0 cm. (w) x 48.0 cm. (d) 2) polyurethane foam: the polyurethane foam is moulded with density = 45 +/ 2 kg/m 3and hardness = 20 +/ 2at 25% compression. 3) armrests: the one piece armrests are injection moulded from black co polymer polypropylene. 4) center tilt synchro mechanism : the mechanism is designed with the following features:· 360 revolving type. · upright position locking. · tilt tension adjustment.· seat/back tilting ratio of 1:3 (60 seat tilt/180 back tilt). 5) pneumatic height adjustment : the pneumatic height adjustment has anadjustment stroke of 12.0 cm. 6) telescopic bellow assembly : the bellow is 3 piece telescopic type and injection moulded in black polypropylene. 7) pedestal assembly : the pedestal is injection moulded in black 30% glass filled nylonand fitted with 5 nos. twin wheel castors. the pedestal is 66.0cm pitch center dia. (76.0 cm with castors.) 8) twin wheel castors : the twin wheel castors are injection moulded in black nylon. , staff chair type i chair of over all size: 58.0cm (w) x 56.5cm (d) x 87.5cm (h) & 48.0cm (sh)seat/back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm (w) x 27.0cm (h).*seat size: 46.0cm (w) x 40.0cm (d).armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. (1”) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. (1”) x 14bg. thick m.s. e.r.w. tube and powder coated. , visiter chair type v s/f/f visitor chair1) seat/back assembly: the seat and back are made up of 1.2 cm. thick hot pressed plywood, upholstered with fabric upholstery covers and moulded polyurethane foam. the back foam is designed with contoured lumbar support for extra comfort. the seat has extra thick foam on front edge to give comfort to popliteal area. mid back size : 47.5 cm. (w) x 58.0cm. (h)seat size : 47.0 cm. (w) x 48.0 cm. (d) 2) polyurethane foam: the polyurethane foam is moulded with density = 45 +/ 2 kg/m 3and hardness = 20 +/ 2at 25% compression. 3) armrests: the one piece armrests are injection moulded from black co polymer polypropylene. 4) tubular frame : the powder coated tubular frame is cantilever type & made of dia 25.4mm x 2mm thk m.s. er.w. tube. , wheel chair type i (l) 790 x (w) 600 x (h) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm (l) x 517 mm ( w) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck .3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement.mx load bearing capacity should be 10 kg. , instrument cabinet type i overall dimensions of 900mmwx 1990mmhx450mmd and should have transparent doors and sides with steel frame work. transparent portion of this cupboard should be made of acrylic of 4mm thick. this cabinet should have 5 adjustable acrylic shelves each of 6 mm thickness. three way lock should be provided of 6 levers. in the front door there should be 4 acrylic sheets and 2 each on both the sides. metal used should be of crca and powder coated for finish. to be provided with rubber shoes to prevent direct contact of cabinet and floor. , hospital curtain tracks & i.v. tree system supply installation testing & commissioning of cubical tracks system made of powder coated aluminium alloy,stain free polyster fabric ,water repellent curtains ,smooth movement ,non sticking runnner with stainless steel hooks made from mirror finish stainless steel ,adjustable height with all accessories. total quantity : 1...

Bihar Medical Service And Infrastructure Corporation Ltd - Bihar

29776690 bids are invited for pile boring, providing and installation bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using direct mud circulation ( dmc ) or bailer and chisel technique by tripod and mechanical winch machine all complete, including removal of excavated earth with all its lifts and leads ( length of pile for payment shall be measured up to bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , reinforment steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , upvc door providing and fixing of factory made upvc white colour casement door, upvc multichambered extruted frame, sash and mullion profile. frame duly reinforced with 1.2mm gi section box tpe chamber and sash with 1.5mm thick gi section ( ± 0.2mm ) based on wind load calculations ( shape and size according to upvc profiles ) , appropiate dimentions of upvc extruded glazing bead, epdm gasket ( k / o type ) , seperate drainage system, ss34 grade friction hinges 2d / 3d plate hinges, zinc alloy ( white powder coated ) casement handle, gi fastener 8x100 mm size for fixing frame to finish wall, plastic packer and caps and necessary steel screws etc.profile of frame and sash shall be metered cut and fusion welded at all corners, mullion shall be also fusion welded / joined mechanically including drilling of holes for fixing hardware and drainage of water etc. after fixing of frames , gap between frame and adjascent wall shall be filled with pu foaam / backer rod required size and the approved quantity. after that sealed with weather proof silicon sealant at both side, all complete as per approved drawing and direction of eic , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , soling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 1 providing and laying vitrified floor tiles in different sizes ( thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including grouting the joints with white cement and matching pigments etc., complete. size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge :flamed finish granite stone slab jet black, cherry red, elitebrown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item ( galvanised@80gsm ) 50 mm long 8mmwith 16 mm thick beveled tegular mineral fibre antimicrobial false ceiling tile confirming to iso 5 ( class 100 ) specifications , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975. the wind load shall be as per provisions of is 875 ( part iii ) . lgsfs frame shall be designed as per is: 801 using commercially available software such as frame cad pro 11.7 / staad pro v8i / architekv2.5.16 / revit architecture 2011 or equivalent. proper usage of connection accessories like heavy duty tension ties, light duty hold ons, twist straps ( to connect truss with wall frames ) , strong tie, tie rod, h brackets, boxing sections, l shaped angles for better structural stability. the framing section shall be cold form c type having minimum web depth 89 mm x 39mm flange x 11mm lip in required length as per structural design requirement duly punched with dimple / slot at required locations as per approved drawings. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , face panel providing and fixing in all exterior face panels breathable vapour barrier underneath the cementfiber board as per national building code 2009 complete as per direction of engineer in charge. , lap siding supplying and installation of moisture resistant / fire resistantlap siding 8 mm thick and width as per standard sizes made ofiber cement board with embossed decorative finish to give pleasing exterior fixed horizontally with staggered joints including minimum over lapof 32 mm external cement fibre boardconforming to is 14862:2000 offixed with self drilling / taping screws / fastners of approved make. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1 new work ( two or more coats ) over and including water tinnable priming coat with cement primer , ex. paint finishing walls with textured exterior paint of required shade : new work ( two or more coats applied @ 3.28 ltr / 10 sqm ) over and including priming coat of exterior primer applied @ 2.20kg / 10 sqm sqm , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel 2 steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , road providing and laying c.c. pavement of mix m 25 with ready mixed concrete from batching plant. the ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc.complete as per specifications and directions of engineer in charge. ( the panel shuttering work shall be paid for separately ) . ( note: cement content considered in this item is @ 330 kg / cum. excess / less cement used as per design mix is payable / recoverableseparately ) . , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 1 providing and fixing salem stainless steel a isi 304 ( 18 / 8 ) kitchen sink as per is: 13983 with ci brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required.kitchen sink with drain board 510x1040mm bowl depth 200mm. , phe 2 providing and fixing salem stainless steel a isi 304 ( 18 / 8 ) kitchen sink as per is: 13983 with ci brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required.sink without drain board 610x510 mm bowl depth 200mm. , phe 3 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing:rectangular shape 453x357 mm , phe 4 providing and fixing toilet paper holder:c.p. brass , phe 5 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixturescomplete, including cutting and making good the walls andlevel whitep.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings andfloors wherever required :white vitreous china orissa pattern w.c. pan of size580x440 mm with integral type foot rests , phe 6 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 7 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 8 providing and fixing cp brass 32mm size bottle trap of approved quality & make and as per the direction of engineer in charge.. ( sink & urinal ) , phe 9 providing & fixingptmt towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealedfittings arrangement of approved quality and colour weighing not less than 88 gms , phe 10 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 11 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 12 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 13 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size660x460 mm with a pair of 15 mm c.p. brass pillar tapswith elbow operated levers , phe 14 providing & fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. , phe 15 providing and fixing white vitreous china laboratory sink with c.i. brackets, c.p. brass chain with rubber plug, 40 mm c.p brass waste and 40mm c.p. brass trap with necessary c.p. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required :size 600x450x200 mm , phe 16 providing and fixing cp brass single lever telephonic wall mixer of quality & make as approved by engineer in charge . a ) 15 mm nominal dia. , phe 17 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 18 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 19 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. , phe 20 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 21 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 22 two or more coats on new work over an under coat ofsuitable shade with ordinary paint of approved brand andmanufacturetwo more coast on new work , phe 23 p / f m.s. cap 100 mm dia , phe 24 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 25 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 26 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 27 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 28 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 30 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 31 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 32 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 33 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 34 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 35 providing and fixing brass stop cock of approved quality15mm nominal bore , phe 36 butterfly valve ( manual ) with c i body ss disc, nitrile rubber seal & o ring pn 16 pressure rating for chilled water / hot eater circulation as specified 65 nominal bore , phe 37 butterfly valve ( manual ) with c i body ss disc, nitrile rubber seal & o ring pn 16 pressure rating for chilled water / hot eater circulation as specified80 nominal bore , phe 38 providing and fixing ball valve ( brass ) of approved quality, high or low pressure, with plastic floats complete25 mm nominal bore , ex. phe 1 providing and fixing c.i. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete ( the tail pieces, tapers etc if required will be paid separately ) :50 mm dia , ex. phe 2 providing and fixing c.i. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete ( the tail pieces, tapers etc if required will be paid separately ) :80 mm dia , ex. phe 3 providing and fixing c.i. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete ( the tail pieces, tapers etc if required will be paid separately ) :100 mm dia , ex. phe 4 providing & fixing c.i.sluice valve ( with cap ) complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately ) 100 mm dia.pipe , ex. phe 5 providing & fixing c.i.sluice valve ( with cap ) complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately ) 150 mm dia.pipe , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm.clear depth and 250mm apron including cost of e / w. involved with 75mmcement concrete ( 1:4:8 ) over one brick designation 100 a flat soling inproper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 8 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia. exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 11 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 450 mm dia rcc pipe , ex. phe 12 inside size 120x90 cm and 90 cm deep including c.i. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg ) :with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , ex. phe 13 providing and fixing square mouth sw gully trap grade ‘a’ complete ci grating brick masonry chamber with bricks of class designation 75 and water tight ci cover with frame of 300 x 300 mm size ( inside ) the weight of cover to be not less than 13.00 kg and frame to be not less than 5 kg. as per standard design. ( cover min. 4.5 kg & frame min.2.7 kg ) 180x150 mm size p type with fps bricks , ex. phe 14 constructing masonry chamber 30x30x50 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement:4 coarce sand ) for stop cock complete with c.i. surface box 100x100x75mm ( inside ) with locking arrangement and rcc top slab 1:2:4 mix ( 1 cement : 2 corase sand: 4 graded stonr aggregate 20mm nominal size ) necessary excavation foundation concret 1:5:10 ( 1 cement:5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortor 1:3 ( 1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design. , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , ex. phe 16 structual steel work welded in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. , ex. phe 17 making connection of gi distribution branch with gi main of 50 80mm nominal bore by providing and fixing tee, including cutting and threading the pipe etc. complete. , rain water harvesting 1 boring / drilling bore well of required dia for casing / strainer pipe, bysuitable method prescribed in is:2800 ( part i ) , including collecting sample from different strata , preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90m depth below ground level.300 mm dia , rain water harvesting 2 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150mm nominal size dia , rain water harvesting 3 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well screen ( rms ) pipes with ribs, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150 mm nominal size dia , rain water harvesting 4 supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 5 supplying, filling, spreading & levelling gravel of size range 5mm to 10mm, in recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 6 supplying, filling, spreading & levelling coarse sand of size range 1.5mm to 2mm, in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 7 providing and fixing bail plug / bottom plug of required dia to the bottom of pipe assembly of tube well as per is:2800 ( part i ) . 100 mm dia , rain water harvesting 8 making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and s.w. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , rain water harvesting 9 constructing soak pit 1.20x1.20x1.20 m filled with brickbats including s.w. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , tubewell 1 boring / drilling bore well of required dia for casing / strainer pipe, bysuitable method prescribed in is:2800 ( part i ) , including collecting sample from different strata , preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90m depth below ground level.300 mm dia , tubewell 2 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150mm nominal size dia , tubewell 3 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.100mm nominal size dia , tubewell 4 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well screen ( rms ) pipes with ribs, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.100 mm nominal size dia , tubewell 5 supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , tubewell 6 providing and fixing bail plug / bottom plug of required dia to the bottom of pipe assembly of tube well as per is:2800 ( part i ) . 100 mm dia , submersible pump 35m deep boring with casing and pipe. supply of pipe etc supplying & installation of suitable 2hp submersible pump b.s or k.s.bor equivalent make with finolex cable 1x3x2.5 squmm ( upto 50mtr ) withflexible conduit 25mm dia, electrical out door pannel with required electrical fitting such as mcb of 0 25amp ( havell or indocopp or mds make ) , volt & ampere meter ( ae make ) , single phase preventer ( minilac or vsp 1 make ) starter ( l&t or bch make ) etc of approved make, 40mm hdpe pipe ( 25 mtr ) and all accessories complete as per requirement of site. , water purifier and cooler 1 fitting and fixing single faucet storage type water cooler ( size 461 mm wide x 582 mm deep x 1217 mm height, weight 46 kg ) fully stainless body having storage capacity of 40 ltrs, cooling capacity of 40 ltrs. / hr. with hermetic type compressor, gas cooled motor equipped with over load protector, condensor for propeller type, thermostat autometically controlled temperature, refrigerent r 22, 230 volt, single phase 50 hertz, maximum current 2.3 amp including plug top and electrical lead wire connection upto 3 metres from the cooler, water inlet and drain out connections complete in all respects of voltas model no 40 / 40 tushar pss type or similar type of approved make. , water purifier and cooler 2 fitting and fixing water purifier for drinking purpose of capacity 6 litres / min, 5 purification system with reverse osmosis system with ultra ventilated membrane, tds500 to 2000 mgl / ppm, auto shut off with microswitch float manual flush facility, tds reduction 90% having automatic backwash system with filteration unit along with all accessories including plug top and electrical lead wire connection upto 3 metres from the purifier, water inlet and drain out connections complete in all respects similar to aquaguard or similar approved make ( model aquasure elegant ro water purifier of size width 360 mm x height 430 mm x depth 235 mm and weight 8.5 kg ) . , fire extinguisher 1 providing and fixing carbon di oxide type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. capacity 4.5 kg. , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 6.0 kg. , electrical 1 wiring for light point / fan point / exhaust fan point / call bellpoint with 1.5 sq.mm frls pvc insulated copper conductorsingle core cable in surface / recessed steel conduit, withmodular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. group c , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , pvc conduit 1 supplying and fixing of following sizes of medium class 20mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , pvc conduit 2 supplying and fixing of following sizes of medium class 32mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , pvc conduit 3 supplying and fixing of following sizes of medium class 50mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , electrical 4 wiring for light / power plug with 2x4 sq. mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit alongwith 1 no. 4 sq. mm frls pvcinsulated copper conductor single core cable for loop earthingas required. , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 4 4 x 6 sq. mm + 2 x 6 sq. mm earth wire , wiring frls pvc insulated copper conductor 5 4 x 10 sq. mm + 2 x 6 sq. mm earth wire , wiring frls pvc insulated copper conductor 6 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 3 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 4 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 5 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 1 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 2 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 3 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 4 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 5 telephone socket outlet , s / f modular switch / socket on the existing modular plate 6 tv antenna socket outlet , s / f modular switch / socket on the existing modular plate 7 bell push , fan regulator on the existing modular plate switch box supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. , call bell / buzze supplying and fixing call bell / buzzer suitable for single phase, 230 volts, complete as required. , electrical 5 supplying & fixing suitable size gi box wih modular plate and cover in front on surface or in recess including providing and fixing 25 a modular socket outlet and 25 a modular sp mcb, “c” curve including connections, painting etc. as required. ( for ac / geyser ) , electrical 6 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface / recessed steel / pvc conduit as required. , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 9 providing and fixing circular / hexagonal cast iron or m.s. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick m.s. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron / m.s. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. clamp shall be made of 12 mm dia m.s. bar bent to shape as per standard drawing. , 40a fp isolator supplying and fixing following rating, four pole, 415 v, isolator in the existing mcb db complete with connections, testing andcommissioning etc. as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 11 supplying and fixing 20 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. , electrical 12 supplying and fixing 30 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. , electrical 17 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way ( 4 + 24 ) , double door , electrical 18 supplying and fixing of following ways surface / recess mounting, vertical type, 415 v, tpn mcb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 a tinned copper bus bar, common neutral link, earth bar, din bar for mounting mcbs ( but without mcbs and incomer ) as required . ( note : vertical type mcb tpdb is normally usedwhere 3 phase outlets are required. ) 4 way ( 4 + 12 ) , double door , electrical 19 supplying and fixing of following ways surface / recess mounting, vertical type, 415 v, tpn mcb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 a tinned copper bus bar, common neutral link, earth bar, din bar for mounting mcbs ( but without mcbs and incomer ) as required . ( note : vertical type mcb tpdb is normally usedwhere 3 phase outlets are required. ) 8 way ( 4 + 24 ) , double door , electrical 20 supplying and fixing cable end box ( loose wire box ) suitable for following triple pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface / recess, complete with testing and commissioning etc.as required. for 8 way, double door fp mcbdb , electrical 21 supplying and fixing cable end box ( loose wire box ) suitable for triple pole and neutral, sheet steel, vertical mcb distribution board, 415 v, on surface / recess, complete with testing and commissioning etc. as required. , 25 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , triple pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a tp mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40a tp mcb , 40a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40a fp mcb , 63a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 100a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , l / f pvc sheathed / xlpe power cable in trench 1 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 95 sq. mm and upto 185 sq. mm , l / f pvc sheathed / xlpe power cable in trench 2 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 185 sq. mm and upto 400 sq. mm , l / f pvc sheathed / xlpe power cable over cable tray above 35 sq. mm and upto 95 sq. mm ( clamped with 25x3mm ms flat clamp ) , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 1 3.5c x 185 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 2 3.5c x 150 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 3 4c x 35 sqmm aluminium conductor cable a2xfy , cable tray 1 supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 100 mm width x 50 mm depth x 1.6 mm thickness , cable tray 2 supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 300 mm width x 50 mm depth x 1.6 mm thickness , cable tray 3 supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 600 mm width x 62.5 mm depth x 2.0 mm thickness , cable tray “bends” 1 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.100 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 2 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.300 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 3 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.600 mm width x 62.5 mm depth x 2.0 mm thickness , mv cable 1 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 185 sqmm, aluminium conductor cable a2xfy , mv cable 2 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 150 sqmm, aluminium conductor cable a2xfy , mv cable 3 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required. 4c x 35 sqmm aluminium conductor cable a2xfy , earthing 1 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 2 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. , earthing 3 earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. , earthing 4 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 5 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , earthing 6 providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required. , earthing 7 providing and fixing 25 mm x 5 mm g.i. strip in 40 mm dia g.i. pipe from earth electrode including connection with g.i. nut, bolt, spring, washer excavation and re filling etc. as required. , earthing 8 providing and fixing 25 mm x 5 mm copper strip in 40 mm dia g.i. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re filling etc. as required. , earthing 9 providing and fixing earth bus of 50 mm x 5 mm copper strip on surface for connections etc. as required. , earthing 10 providing and fixing earth bus of 50 mm x 5 mm gi strip on surface for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling , fiting & fixtures 4 supplying and fixing recess mounted 12 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 6 supply, installation, testing and commissioning of 400 mm sweep, 65w, blade material aluminium blades , speed & oscillation 3 speed, pull cord for speed and oscillation.air delivery minimum 72 m³ / min, speed minimun 1350 revolution per minute.suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. , fiting & fixtures 8 supplying installation testing & commissioning ofb22 based 9w led 3 star bulb with 850 lumen, 6k color temperature including holder. , fiting & fixtures 9 supplying installation testing & commissioning of black painted extruded aluminium housing. green / red led’s mounted inside the housing. laser engraved signage matter on single / double acrylic sheet fixed on one side suitable for wall / ceiling / suspension type single / double sided display. in double sided version black paper is inserted. ni cd battery back up to 2 hrs. ( charged up to 8 10 hrs ) .mounting strings provided for pendent mounting operating voltage 150 280v ac ambient operating temperature. – 0 to 450c ingress protection – ip42.including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required.220208 besl 03 led ssd wbb green 240 3 8wor220209 besl 03 led ssd wbb red 240 3 8wor220210 besl 03 led dsd wbb green 240 3 8wor220211 besl 03 led dsd wbb red 240 3 8w , fiting & fixtures 10 supply, installation, testing and commissioning of 600 mm sweep, bee 5 star rated, ceiling fan with brush less direct current ( bldc ) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value ( cmm / w ) minimum 6.85, air delivery minimum 135cmm, 350 rpm ( tolerance as per is : 374 2019 ) , thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c ( max. ) , insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. , civil & misc works1 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. , civil & misc works2 providing and fixing h.t. danger notice plate of 250 mm x 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. , civil & misc works3 supplying and making cable route marker with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm x 60 cm at the bottom and 50 cm x 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. , civil & misc works4 supplying and fixing cable route marker with 10 cm x 10 cm x 5 mm thick g.i. plate with inscription there on, bolted / welded to 35 mm x 35 mm x 6 mm angle iron, 60 cm long and fixing the same in ground as required. , civil & misc works5 providing & fixing in position 1000 mm wide , electrical insulating rubber mats as per is 15652:2006, 2 mm thick, suitable up to 1.1 kv , fire retardant, no effect of acids, alkalis and transformer oils, moisture proof, high tensile strengthandtexture finish / cloth impression ( anti slip , marking on top ) , civil & misc works6 supply & fixing shock treatment chart duly mounted on a wooden frame with 5 mm thick glass as required ( approx front area 1.20 sq metre ) , 20 kvaups supplying, installation, testing and commissioningof online double conversion fully microprocessor based , indoor type, compact ups system of following rating with igbt based pwm technology to achieve thd < 3% and input power factor of greater than 0.95 at 50% loading, suitable for three phase ac input voltage 380 v to 440 v, 50 hz +3% / 3 % and three phase ac output voltage 415 ± 1% volts & frequency 50 ± 0.5 hz , inbuilt isolation transformer, necessary vrla batteries of suitable size having 30 minutes back up time , mounting rack including and suitable size connecting cable ( for ups to battery and battery to battery ) , static and maintenance bypass switch, snmp card for rs232 / ethernet ip computability for operation and monitoring etc. with all components as mentioned , specifications, complete as required.note : concerning vendor needs to furnish the battery sizing calculations at the time of ga approval and battery size has to be as per the approved ga drawing. , external lighting 1 supply and erection of 4 metre height hot dip galvanized octagonal street light pole with following arm with top dia 70 mm and bottom dia a / f 130 mm, made of 3 mm thick sheet along with base plate of size 220 x 220 x 12 mm , small door opening for junction box mounting with mcb & connector, cement concrete of 1:3:6 including excavation, refilling and suitable size foundation bolts with template and all complete jobas required. ( but without pole collar ) single arm , external lighting 2 supplying and fixing 40 / 45 watt led type street light with die cast aluminium housing for ingress protection of ip65 and complete with all accessories etc, onpole / building including connection with fr pvc insulated copper conductor cable and earthing the body etc. as required. , transformer supplying, installation testing and commissioning of following rating, distribution transformer, suitable for 3 phase, 50hz, ac supply, dyn 11 vector group, core made of good quality crgo, windings made of double wound copper with approved danger and arc flash signages and with all components as mentioned , specifications and sld and complete as required. power rating 250 kva , 11 kv ht dp structure / ht cable 1 supplying 11kv ( earthed ) grade, xlpe insulated, heavy duty frls type, armoured cables suitable for 11kv, 50hz, ac system with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel flat armouring and with all components as mentioned in boq, specifications and sld, complete as required.3 core x 240 sq. mm , 11 kv ht dp structure / ht cable 2 supply, installation, testing and commissioning of 11 kv dp structure as per cei & hpseb norms & comprising of the following, but not limited to it for completion of worksfor the followingrsj pole of 9.15 mt length of size 175 x 90 mm complete with suitable m.s. base plate welded at bottombase plate 2 nos. , indoor cable end termination 2 supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, xlpe aluminium conductor cable of 11 kv grade as required. 300 sq. mm , outdoor cable end termination supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, xlpe aluminium conductor cable of 11 kv grade as required. 300 sq. mm , main lt panel main lt panel ( refer sld for detail ) supply, installation, testing and commissioning of indoor floor mounted / wall mounted, ip42 ( indoor ) and ip55 ( outdoor ) , factory built, modular, sectionalised, compartmentalized, extendable type lt cubicle panel of suitable size suitable for operation on 433 / 415 volts, 50 hz ac 3 phase 4 wire supply system fabricated from crca sheet steel of 2mm thick for , apfc panel apfc panel ( 200 kvar ) outoor type ( refer sld for detail ) , ip based cctv system 1 sitc of 2 megapixel @ 25fps, h.265 ip bullet camera, 1 / 2.9 cmos with 2.8~12mm varifocal lens, 0 lux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 2 sitc of 2 megapixel @ 25fps, h.265 ip dome camera, 1 / 2.9 cmos with 3.6 fixed mm 0 lux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 4 sitc of 32ch 4k ivr , h.265 / h.264 • 1080p real time • 4k display • dual lan • 8x hdd • raid •web plugin free h.265 / h.264 compression technology 4k display for clear monitoring up to 1080p 16ch decoding ability smart search ii smart vca event searchsupport raid 0, 1, 5 supported to prevent from recording data loss browsers supported: ie , smart functions : target count, electric fence, face detection, humaniod detection, retrograde detection, leave position detectio output, local & network backup etc. complete as required. , cctv 5 sitc of harddiskdrive8tb, 24 / 7surveillance category only complete etc as required.etc.all complete , cctv 6 sitc of 55 led narrow bazel for monitoring for nvr server etc. all complete. , cctv 7 sitc of rj 45 outlets near the cameras etc. all complete. etc. all complete. , cctv 8 sitc of cat 6 patch cords 1 meter high quality four pair twisted stranded cable terminated with rj45 modular plugs at both the ends. , integrated it and epabx system sitcof cat 6 48 port jack panel for data as per given specification etc. all complete. , epabx system 2 sitcof cat 6 48 port jack panel for voice as per given specification etc. all complete. , epabx system 3 sitc of lszh cat 6 speed unshielded twisted pair computer cable with 23 awg solid copper conductors in existing concealed / surface conduits / raceways complete 305 mtr. roll as per specification etc. all complete. , epabx system 4 sitc of cat6 io, face plate, wall box combo2 port etc. all complete. , epabx system 5 sitcof cat 6 mounting cords 7 feet for data as per given specification etc. all complete. , epabx system 6 sitcof cat 6 patch cords 4 feet for telephone as per given specification etc. all complete. , epabx system 7 sitc of 24 port l2 managed 10 / 100 / 1000 mbps non poe switch with 4 sfp port , for data pointsrack mountable etc. all complete. , epabx system 8 sitc of 24 port l2 managed poe 10 / 100 / 1000 mbps switch with 4 sfp port , for cctv rack mountable etc. all complete. , epabx system 9 sitc of 24 port smart managed non poe with 4 sfp port rack mountable etc. all complete. , epabx system 10 sitc of 15 u mountingrack with ventilation, sliding shelves, power strips, etc. all complete. , epabx system 11 sitc of ip pbx for with 8 trunk 1 pri& 8 digital and 32 analog extension expendble upto 64 extesionsy etc all complete. , epabx system 12 25 pair riser cable , epabx system 13 mdf box25 pair with 20 pairkrone module , epabx system 14 supply, installation, testing & commissioning of analog phone with speaker , small display etc. all complete. , epabx system 15 client workstation supply, installation, testing & commissioning of client workstation as per following specifications:intel core i5 7700k, 4.2ghz, os genuine microsoft microsoft® windows 10 enterprise 64 bit, ram 16gb, memory 500 gbssd +1tb hdd 7200 rpm class graphic card in built processor graphics ( gpu ) :intel® hd graphics 630 and geforce gtx 970 4gb pcie x 16 lp supporting 2 / 4 monitors., two ( 2 ) pci express expansion slots 2 / 4 usb, 3.0 serial, and 2 hdmi / vga adaptor, cd / dvd rom.; usb keyboard and mouse, ups, associated cables etc. and other required software to control nvr in control room including centralized video management software as per the requirement of the successful operation of the surveillance system complete as required in accordance with laid specification or upto the satisfaction of engineer in charge. , signage 1 providing & fixing of building direction signage mounted on pole, with pole of 100x100mm shs ( square hollow section ) of height of 5600mm, and sign size of 900x1050, sign made of aluminiu c section of 60mm with internal framing to support the frame in ms tubes hollow section, frame work duly painted with anti rust coatings, with facia of 3mm thick exterior grade aluminium composite panel, cladded with uv cured digital printed retroreflective sheet of 3m make, and back panel of 3mm exterior grade acp, all pipes to be painted in approved color. cost shall includecost towards installation, including excuvation and filling up with specified pcc and fixing of foundation bolts as specified, also it shall include the designing charges.all complete as per direction by engineer in charge. , signage 2 providing & fixing of prohibition sign silk screen printed of approved colors, on acp of exterior grade, of size 300x300mm, all fixtures in stainless steel as per design, it shall include the designing charges .all complete as per direction by engineer in charge. , signage 3 providing & fixing traffic regulatory parking signage mounted on pole, with pole of 50x50mm shs ( square hollow section ) of height of 300mm, and sign size of 750x750, sign made of aluminium sheet of 3 mm thickness with aluminium supported profile to the frame of ms tube hollow section, aluminium sheet to be cladded with uv printed retroreflective sheet of 3m make frame work duly painted with anti rust coatings., all pipe to be painted in apppproved color. cost shall include cost towards installation, including excuvation and filling up with specified pcc and fixing of foundation bolts as specified, also it shall include the designing charges.all complete as per direction by engineer in charge. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , 2 tr air conditioning 1 split ac ( inverter model ) : supply, installation, testing, commissioning of split type wall mounted air conditioning units of following capacity including inddor, outdoor unit fitted with inverter based rotary compressor fitted with rotary compressor, copper condensor and first charge refrigent r410a / eco friendly green gas only, all complete including all electrical connections to the electrical power supply system of the building, includingbut not limited to supply of all electrical plugs, etc., as necessary, lengthening of all electrical wires of ac units ( both indoor and outdoor ) , drain pipe andincluding suitable voltage stabilisers, etc. so as to place them in a concealed manner in the desired position. the copper pipes and electrical cables shall be concealed in approved manner and neatly run in straight lines in a workman like manner with proper supports. complete supply and installation of split2 tr star rating 3 star , refrigerant piping 1 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 25 mm od, wall thickness >= 1.2 mm ( insulation 19 mm thick ) , refrigerant piping 2 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 19.1 mm od, wall thickness >= 1.0 mm ( insulation 13 mm thick ) , refrigerant piping 3 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 15.9 mm od, wall thickness >= 0.8 mm ( insulation 13 mm thick ) , refrigerant piping 4 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 9.5 mm od, wall thickness >= 0.8 mm ( insulation 13 mm thick ) , drain piping 1 providing and fixing of cpvc 6 kg / cm2 drainpiping complete with fittings, supports, 6 mm thick closed cell elastomeric insulation as per specifications and drawings. 20 mm , drain piping 2 providing and fixing of cpvc 6 kg / cm2 drainpiping complete with fittings, supports, 6 mm thick closed cell elastomeric insulation as per specifications and drawings. 32 mm , main oxygen manifold supply, installation, testing and commissioning of following gas manifold system ( excluding cylinders ) . the manifold is configured for designed numbers of cylinders and is suitable to withstand a pressure of 145 kg / cm2, along withhigh pressure copper annealed tail pipes with end brass adapter suitable for cylinders and manifold. top frame comprising of high pressure copper pipes of size 1 / 2” nb x 15swg with high pressure brass fittings made of high tensile brass and connections through nonreturn valves, the design of middle and bottomframes is provided to fit both round and flat bottom cylinders safely. the manifold is tested ( hydraulically ) at 3500 psig. ( it should be ce and iso 13485 certified ) mani fold oxygen manifold 4 + 4 cylinder banks complete with nrv, middle frame, bottom frame with ce marked, , emergency manifold emergency oxygen manifold 01 + 01 cylinder emergency manifold with complete regulator, nrv, middle frame & bottom frame, , control panelfor oxygen fully automatic three port control panel for oxygen supply, installation, testing and commissioning of automatic manifold control panel would provide a duty or standby gas supply from two cylinder banks with automaticchangeover the manifold indicates local status and has a remote indicator facility. automaticmanifold control panel would be designed to supply the mgps with a constant pressure supply via a control panel form two equal banks of cylinders and the changeover from the , emergency manifold line regulator emergency manifold line regulator supply, installation, testing and commissioning of emergency manifold line regulator i n p u t p r e s s u r e 1 5 0 k g / c m 2 working pressure 4 kg / cm2 it should be ce and iso 13485 certified.oxygen input pressure 150 kg / cm2 working pressure 4 kg / cm2capacity : 1500 lpm , cylinderconnectingpipe ( pig tail ) supply, installation, testing and commissioning of cylinder connecting pipe ( pig tail ) made up of flexible ss hose with safety cord 5 / 8 inch bsp gland nut and one side 1 / 2 inch bsp internal threads having one meter length. ( oxygen 24 , n2o 10, co2 4 ) , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve, supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified.42mm , isolation valve 2 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 28mm , isolation valve 3 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 22mm , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness , pipeline 4 medical grade copper pipeline ( in mtrs. ) as per en 13348, 28 mm ( od ) x 0.9 mm thickness , pipeline 5 medical grade copper pipeline ( in mtrs. ) as per en 13348, 42 mm ( od ) x 1.2 mm thickness , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 2268 mm x ( w ) 922 mm x ( h ) 610 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crca , paediatric bed with mattress paediatric bed of overall sizes in mm: 1500 ( l ) x 850 ( w ) x 1210 ( h ) flat single section bed with grille frame on 4 sides.suitable for children up to 12 years.drop down grill frame on both sides for protection of the patient.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral white , bed side locker type i over all dimension :402mmlx422mm wx840mm ht .locker should have one cabinet and one drawer unit .both provided with cam lock .there should be gap between drawer and unit to keep general items for frequesnt use castors are provided for easy handling .drawer made up of crca sheet 1 mm thick and has ball slide for easy operation .top ss 304 sheet 0.8 mm thick castors 50 mmdia , hamdle abs ..powder coating of epoxy polyester , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , strecher on trolley type i 2005mm ( l ) x666mm ( w ) x827mm ( h ) .the trolley should be made of 31.75 and 25.4 mm dia 1.6 mm thick erw tube.holder for stretcher should be made up of mild steel.castor should be of 200 mm dia , diagonal locking castor.stretcher should be made up oferw tubeof dia 25.4 mm and thickness 1.6 mm.top sheet should be made of crca sheetof thickness 1.2 mm with contour shape to accommodate patient.iv pole holder should be made ofms .maximum safe work load should be 135 kg.to ensure qood quality welding co2 argonprocess should be adhered to.all metal componentsshould be pre treated with zinc phosphating in 9 tank porcess and then powder coated with anti microbialepoxy polyster powder coating.goods should be supplied in knocked down construction to reduce carbon emission. performance test :proof loading test , cycle tests , impact test, salt spray test, castor break test, the manufacturer should compilant with iso 9001, 14001, 13485, ohsas 1800 and ce certification. , doctor desk type x s / f / f executive table main desk should be of dimesion : 1350w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. side panels : ( black ) made form 18mm thick plt with pvc lipping.modesty panel : made form 18mm thick plt with pvc lipping. bigger upper panel in black and smaller lower panel in white cedar. made from 18mm thick plt with pvc lipping. mobile pedestal : one box and one filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , chair type iii s / f / f executive chair1 ) seat / back assembly: the seat and back are made up of 1.2 cm. thick hot pressed plywood, upholstered withfabric upholstery covers and moulded polyurethane foam. the back foam is designed with contoured lumbar support for extra comfort. the seat has extra thick foam on front edge to give comfort to popliteal area.high back size : 47.5 cm ( w ) x 69.5 cm ( h ) seat size : 47.0 cm. ( w ) x 48.0 cm. ( d ) 2 ) polyurethane foam: the polyurethane foam is moulded with density = 45 + / 2 kg / m 3and hardness = 20 + / 2at 25% compression. 3 ) armrests: the one piece armrests are injection moulded from black co polymer polypropylene. 4 ) center tilt synchro mechanism : the mechanism is designed with the following features:· 360 revolving type. · upright position locking. · tilt tension adjustment.· seat / back tilting ratio of 1:3 ( 60 seat tilt / 180 back tilt ) . 5 ) pneumatic height adjustment : the pneumatic height adjustment has anadjustment stroke of 12.0 cm. 6 ) telescopic bellow assembly : the bellow is 3 piece telescopic type and injection moulded in black polypropylene. 7 ) pedestal assembly : the pedestal is injection moulded in black 30% glass filled nylonand fitted with 5 nos. twin wheel castors. the pedestal is 66.0cm pitch center dia. ( 76.0 cm with castors. ) 8 ) twin wheel castors : the twin wheel castors are injection moulded in black nylon. , staff chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , visiter chair type v s / f / f visitor chair1 ) seat / back assembly: the seat and back are made up of 1.2 cm. thick hot pressed plywood, upholstered with fabric upholstery covers and moulded polyurethane foam. the back foam is designed with contoured lumbar support for extra comfort. the seat has extra thick foam on front edge to give comfort to popliteal area. mid back size : 47.5 cm. ( w ) x 58.0cm. ( h ) seat size : 47.0 cm. ( w ) x 48.0 cm. ( d ) 2 ) polyurethane foam: the polyurethane foam is moulded with density = 45 + / 2 kg / m 3and hardness = 20 + / 2at 25% compression. 3 ) armrests: the one piece armrests are injection moulded from black co polymer polypropylene. 4 ) tubular frame : the powder coated tubular frame is cantilever type & made of dia 25.4mm x 2mm thk m.s. er.w. tube. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck .3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement.mx load bearing capacity should be 10 kg. , instrument cabinet type i overall dimensions of 900mmwx 1990mmhx450mmd and should have transparent doors and sides with steel frame work. transparent portion of this cupboard should be made of acrylic of 4mm thick. this cabinet should have 5 adjustable acrylic shelves each of 6 mm thickness. three way lock should be provided of 6 levers. in the front door there should be 4 acrylic sheets and 2 each on both the sides. metal used should be of crca and powder coated for finish. to be provided with rubber shoes to prevent direct contact of cabinet and floor. , hospital curtain tracks & i.v. tree system supply installation testing & commissioning of cubical tracks system made of powder coated aluminium alloy, stain free polyster fabric , water repellent curtains , smooth movement , non sticking runnner with stainless steel hooks made from mirror finish stainless steel , adjustable height with all accessories. total quantity : 1...

Bihar Medical Service And Infrastructure Corporation Ltd - Bihar

29776615 bids are invited for pile boring, providing and installation bored cast in situ reinforced cement concrete piles of grade m 25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using direct mud circulation ( dmc ) or bailer and chisel technique by tripod and mechanical winch machine all complete, including removal of excavated earth with all its lifts and leads ( length of pile for payment shall be measured up to bottom of pile cap ) .450mm dia piles ( inclusive of carriage ) , pcc providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering all work up to plinthlevel : 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) ( inclusive of carriage ) , rcc providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, portland pozzolana / ordinary portland / portland slag cement, admixtures in recommended proportion as per is: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer in charge; for the following grades of concrete. note: extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. in case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re design the mix or bear the cost of extra cement. ( inclusive of carriage ) , brick work brick work with bricks of class designation 100a in foundations and plinthin :cement mortar 1:4 ( 1 cement : 4 coarse sand ) ( inclusive of carriage ) , sand filing supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. ( inclusive of carriage ) with lead upto 3 km , shuttering centering and shuttering including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete , reinforment steel steel reinforcement for r.c.c. work ready to use cut and bend rebars of approved make from factory / workshop to construction site including placing in position and binding all complete thermo mechanically treated bars of grade fe 500d or more. , plinth protection making plinth protection 50mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand ( zone iii ) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources ) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. , door & window providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :powder coated aluminium ( minimum thickness of powder coating 50 micron ) , glass providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) , upvc door providing and fixing of factory made upvc white colour casement door, upvc multichambered extruted frame, sash and mullion profile. frame duly reinforced with 1.2mm gi section box tpe chamber and sash with 1.5mm thick gi section ( ± 0.2mm ) based on wind load calculations ( shape and size according to upvc profiles ) , appropiate dimentions of upvc extruded glazing bead, epdm gasket ( k / o type ) , seperate drainage system, ss34 grade friction hinges 2d / 3d plate hinges, zinc alloy ( white powder coated ) casement handle, gi fastener 8x100 mm size for fixing frame to finish wall, plastic packer and caps and necessary steel screws etc.profile of frame and sash shall be metered cut and fusion welded at all corners, mullion shall be also fusion welded / joined mechanically including drilling of holes for fixing hardware and drainage of water etc. after fixing of frames , gap between frame and adjascent wall shall be filled with pu foaam / backer rod required size and the approved quantity. after that sealed with weather proof silicon sealant at both side, all complete as per approved drawing and direction of eic , door closer providing and fixing aluminium die cast body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm ) , with necessary accessories and screws etc. complete. , door providing and fixing isi marked flush door shutters conforming to is : 2202 ( part i ) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 mm thick including stainless steel butt hinges wirhnecessary screws , door stopper providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete. single rubber stopper , soling providing designation 100 a one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as perbuilding specification and direction of e / l, , tile 1 providing and laying vitrified floor tiles in different sizes ( thickness to be specified by the manufacturer ) with water absorption less than 0.08% and conforming to is: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including grouting the joints with white cement and matching pigments etc., complete. size of tile 600x600 mm , tile 2 providing and laying ceramic glazed floor tiles of size 300x300 mm ( thickness to be specified by the manufacturer ) of 1st quality conforming to is : 15622 of approved make in colours such as white, ivory, grey, fume red brown, laid on 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) , jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc., complete. , tile 3 providing and fixing ist quality ceramic glazed wall tiles conforming to is: 15622 ( thickness to be specified by the manufacturer ) , of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by engineer in charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand ) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. , granite providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1:4 ( 1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the engineer in charge :flamed finish granite stone slab jet black, cherry red, elitebrown, cat eye or equivalent. , false ceiling providing and fixing mineral fibre false ceiling tiles at all heights of size 595x595mm of approved texture, design and pattern. the tiles should have humidity resistance ( rh ) of 99%, light reflectance ? 85%, thermal conductivity k = 0.052 0.057 w / m k, fire performance as per ( bs 476 pt 6 &7 ) in true horizontal level suspended on interlocking t grid of hot dipped all round galvanized iron section of 0.33 mm thick ( galvanized @120 gsm ) comprising of main t runners of 15x32 mm of length 3000 mm, cross t of size 15x32mm of length 1200 mm and secondary intermediate cross t of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item ( galvanised@80gsm ) 50 mm long 8mmwith 16 mm thick beveled tegular mineral fibre antimicrobial false ceiling tile confirming to iso 5 ( class 100 ) specifications , pre fabsteel designing, providing, installing and fixing factory finished custom designed cold form light gauge steel framed super structure comprising of steel wall panel, trusses, purlins etc manufactured out of minimum 0.75 mm thick steel sheet as per design requirements. the steel sheet shall be galvanized ( az 150gms aluminium zinc alloy coated steel having minimum yield strength 300 550 mpa ) conforming to aisi specifications and ibc 2009 for cold formed steel framing and construction and also as per is: 875 1987, iso 800 1984 and is:801 1975. the wind load shall be as per provisions of is 875 ( part iii ) . lgsfs frame shall be designed as per is: 801 using commercially available software such as frame cad pro 11.7 / staad pro v8i / architekv2.5.16 / revit architecture 2011 or equivalent. proper usage of connection accessories like heavy duty tension ties, light duty hold ons, twist straps ( to connect truss with wall frames ) , strong tie, tie rod, h brackets, boxing sections, l shaped angles for better structural stability. the framing section shall be cold form c type having minimum web depth 89 mm x 39mm flange x 11mm lip in required length as per structural design requirement duly punched with dimple / slot at required locations as per approved drawings. , pre fabwall providing and fixing of external wall system on light gauge steel frame work with outer face cement boards as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make. , pre fabin. wall providing and fixing internal wall panels on light gauge steel frame work with 12.5mm thick gypsum plaster board conforming is 2095:2011 fixed on cement board as per standard sizes fixed with self drilling / taping screws / fasteners @ 60cm c / c of approved make, screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm. proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish. ( cost of frame work to be paid for separately , roof sheet supply & installation of precoated galvanised iron profile sheets ( size, shape and pitch of corrugation as approved by engineer in charge ) 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling / self tapping screws of size ( 5.5x 55mm ) with epdm seal or with polymer coated j or l hooks, bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead complete upto any pitch in horizontal / vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. , ridge plain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : ridges plain ( 500 600mm ) . , gutter drain providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + / 5% total coated thickness ( tct ) thick zinc coating 120gsm as per is: 277 in 240mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumen washers complete : gutter , flashing providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm + 5% total coated thickness ( tct ) , zinc coating 120gsm as per is: 277 in 240mpasteel grade, 5 7 microns epoxy primer on both side of the sheet and polyester topcoat 15 18 microns using self drilling / self tapping screws or with polymer coated j or l hooks, bolts and nuts and or g.i. seam bolts and nuts, g.i. plain and bitumenwashers complete :flashings / aprons. ( upto 600 mm ) , under deck insulation providing and fixing thermal insulation of ceiling ( under deck insulation ) with resin bonded rockwool conforming to is: 8183, density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to ceiling with metallic cleats ( 50x50x3 mm ) @ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top most ceiling of building. , resin bonded rock wool providing and fixing thermal insulation with resin bonded rock wool conforming to is: 8183, having density 48 kg / m3, 50 mm thick, wrapped in 200 g virgin polythene bags fixed to wall with screw, rawel plug & washers and held and in position by criss cossing gi wire etc. complete as per directions of engineerin charge. , face panel providing and fixing in all exterior face panels breathable vapour barrier underneath the cementfiber board as per national building code 2009 complete as per direction of engineer in charge. , lap siding supplying and installation of moisture resistant / fire resistantlap siding 8 mm thick and width as per standard sizes made ofiber cement board with embossed decorative finish to give pleasing exterior fixed horizontally with staggered joints including minimum over lapof 32 mm external cement fibre boardconforming to is 14862:2000 offixed with self drilling / taping screws / fastners of approved make. , putty providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. , distemper distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1 new work ( two or more coats ) over and including water tinnable priming coat with cement primer , ex. paint finishing walls with textured exterior paint of required shade : new work ( two or more coats applied @ 3.28 ltr / 10 sqm ) over and including priming coat of exterior primer applied @ 2.20kg / 10 sqm sqm , oil paint painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work . , steel 2 steel work in built up tubular ( round, square or rectangular hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. hot finished welded type tubes , excavation earth work in excavation over areas ( exceeding 30 cm in depth. 1.5 m in width as well es 10 sqm on plan ) including disposal of excavated earth , lead upto 50 m and lift upto 1.5 m; disposed earth to be levelled and neatly dressed. , road providing and laying c.c. pavement of mix m 25 with ready mixed concrete from batching plant. the ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc.complete as per specifications and directions of engineer in charge. ( the panel shuttering work shall be paid for separately ) . ( note: cement content considered in this item is @ 330 kg / cum. excess / less cement used as per design mix is payable / recoverableseparately ) . , paver block providing and laying 60 mm thick factory made cement concrete interlocking paver block of m 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thickcompacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of engineer in charge. , phe 1 providing and fixing salem stainless steel a isi 304 ( 18 / 8 ) kitchen sink as per is: 13983 with ci brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required.kitchen sink with drain board 510x1040mm bowl depth 200mm. , phe 2 providing and fixing salem stainless steel a isi 304 ( 18 / 8 ) kitchen sink as per is: 13983 with ci brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required.sink without drain board 610x510 mm bowl depth 200mm. , phe 3 providing and fixing mirror of superior glass ( of approved quality ) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing:rectangular shape 453x357 mm , phe 4 providing and fixing toilet paper holder:c.p. brass , phe 5 providing and fixing water closet squatting pan ( indian type w.c.pan ) with 100 mm sand cast iron p or s trap, 10 litre low fixturescomplete, including cutting and making good the walls andlevel whitep.v.c. flushing cistern, including flush pipe, with manually controlleddevice ( handle lever ) conforming to is : 7231, with all fittings andfloors wherever required :white vitreous china orissa pattern w.c. pan of size580x440 mm with integral type foot rests , phe 6 providing and fixing white vitreous china pedestal type water closet ( european type w.c. pan ) with seat and lid, 10 litre low level white p.v.c. flushing cistern, including flush pipe, with manually controlled device ( handle lever ) , conforming to is : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid , phe 7 providing and fixing 8 mm dia c.p. / s.s. jet with flexible tube upto 1 metre long with s.s. triangular plate to eureopean type w.c. of quality and make as approved by engineer in charge , phe 8 providing and fixing cp brass 32mm size bottle trap of approved quality & make and as per the direction of engineer in charge.. ( sink & urinal ) , phe 9 providing & fixingptmt towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealedfittings arrangement of approved quality and colour weighing not less than 88 gms , phe 10 providing and fixing c.p. brass long body bib cock of approved quality conforming to is standards and weighing not less than 690 gms.15mm nominal bore , phe 11 providing and fixing c.p. brass bib cock of approved quality confirming to is:893115mm nominal bore , phe 12 providing and fixing c.p.brass angle valve for basin mixer and geyser points of approved quality conforming to is 8931 a ) 15 mm nominal bore.15 mm nominal bore , phe 13 providing and fixing wash bashin with c.i. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required white vitreous china surgeon type wash basin of size660x460 mm with a pair of 15 mm c.p. brass pillar tapswith elbow operated levers , phe 14 providing & fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. , phe 15 providing and fixing white vitreous china laboratory sink with c.i. brackets, c.p. brass chain with rubber plug, 40 mm c.p brass waste and 40mm c.p. brass trap with necessary c.p. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required :size 600x450x200 mm , phe 16 providing and fixing cp brass single lever telephonic wall mixer of quality & make as approved by engineer in charge . a ) 15 mm nominal dia. , phe 17 providing and fixing cp brass shower rose with 15 or 20 mm inlet100 mm diameter , phe 18 providing and fixing ptmt towel rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. , phe 19 providing and fixing ptmt liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. , phe 20 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 40 mm dia, nominal bore , phe 21 providing and fixing g.i. pipes complete with gi fittings and clamps including cutting and making good the walls etc. ( internal work ) 50 mm dia, nominal bore , phe 22 two or more coats on new work over an under coat ofsuitable shade with ordinary paint of approved brand andmanufacturetwo more coast on new work , phe 23 p / f m.s. cap 100 mm dia , phe 24 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.75 mm dia pipe , phe 25 providing and fixing, upvcpipes 6 kg / cm2 ( is: 4985 ) including all fittings ( plain or door ) e.g. bends, junction, offsets, access pieces, jointing with rubber ring / solvent cement joints includingrequired suports, cutting chase or holes in walls and floors and making good where required.110 mm dia pipe , phe 26 providing & fixing on wall face unplasticised rigid pvc rain water pipes conforming to is:13592 tyape a included jointing with seal ring conforning to is:5382 leaving 10 mm gap for thermal expansion. ( i ) single socketed pipes.110 mm diameter , phe 27 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. coupler 110 mm diameter , phe 28 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. bend 87.5 deg 110 mm diameter , phe 29 providing, fixing on wall face unplasticised pvc moulded fittings / accessories for unplasticised rigid pvc rain water pipes conforming to is ; 13592 type a including jointing with seal ring conforming to is ; 5382 leaving 10 mm gap for thermal expansion. shoe 110mm shoe , phe 30 providing & fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of 50x50x50mm hard wood plugs, screwed with .m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1cement : 4 coarse sand ) and making good the wall etc. complete.110 mm dia , phe 31 providing and fixing cpvc pipes having thermal stability for hot and cold water supply including all cpvc plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. 20 mm nominal outer dia pipes , phe 32 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 25mm dia, nominal bore , phe 33 providing and fixing of gun metal gate valve with ci wheel of approved quality ( screwed ends ) 32 mm dia, nominal bore , phe 34 providing and fixing gun metal non return valve of approved quality ( pn 1.6 ) 40 nominal bore , phe 35 providing and fixing brass stop cock of approved quality15mm nominal bore , phe 36 butterfly valve ( manual ) with c i body ss disc, nitrile rubber seal & o ring pn 16 pressure rating for chilled water / hot eater circulation as specified 65 nominal bore , phe 37 butterfly valve ( manual ) with c i body ss disc, nitrile rubber seal & o ring pn 16 pressure rating for chilled water / hot eater circulation as specified80 nominal bore , phe 38 providing and fixing ball valve ( brass ) of approved quality, high or low pressure, with plastic floats complete25 mm nominal bore , ex. phe 1 providing and fixing c.i. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete ( the tail pieces, tapers etc if required will be paid separately ) :50 mm dia , ex. phe 2 providing and fixing c.i. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete ( the tail pieces, tapers etc if required will be paid separately ) :80 mm dia , ex. phe 3 providing and fixing c.i. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete ( the tail pieces, tapers etc if required will be paid separately ) :100 mm dia , ex. phe 4 providing & fixing c.i.sluice valve ( with cap ) complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately ) 100 mm dia.pipe , ex. phe 5 providing & fixing c.i.sluice valve ( with cap ) complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately ) 150 mm dia.pipe , ex. phe 6 providing 250mm wide brick drain in cement mortar ( 1:6 ) with av. 150mm.clear depth and 250mm apron including cost of e / w. involved with 75mmcement concrete ( 1:4:8 ) over one brick designation 100 a flat soling inproper grade and slope at the base.the drain duly.plastered in cm. ( 1:3 ) with punning over exposed surface all complete as per buildingspecification and direction of e / l, , ex. phe 7 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia.but not exceeding 300mm dia. , ex. phe 8 excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottom depth upto 1.5 m including getting out the excavated soil ( hard or soft ) and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 50m. [ hard / dense soil ] pipes, cables etc.exceeding 80mm dia. exceeding 300mm dia. , ex. phe 9 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 250 mm dia rcc pipe , ex. phe 10 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 300 mm dia rcc pipe , ex. phe 11 providing and laying non pressure np2 class ( light duty ) rcc pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand ) including testing of joints etc. complete. ( for storm drainage ) 450 mm dia rcc pipe , ex. phe 12 inside size 120x90 cm and 90 cm deep including c.i. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg ) :with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , ex. phe 13 providing and fixing square mouth sw gully trap grade ‘a’ complete ci grating brick masonry chamber with bricks of class designation 75 and water tight ci cover with frame of 300 x 300 mm size ( inside ) the weight of cover to be not less than 13.00 kg and frame to be not less than 5 kg. as per standard design. ( cover min. 4.5 kg & frame min.2.7 kg ) 180x150 mm size p type with fps bricks , ex. phe 14 constructing masonry chamber 30x30x50 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement:4 coarce sand ) for stop cock complete with c.i. surface box 100x100x75mm ( inside ) with locking arrangement and rcc top slab 1:2:4 mix ( 1 cement : 2 corase sand: 4 graded stonr aggregate 20mm nominal size ) necessary excavation foundation concret 1:5:10 ( 1 cement:5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortor 1:3 ( 1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design. , ex. phe 15 constructing masonry chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 ( 1 cement: 4 coarse sand ) for sluice valve, with c.i. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with channel lid and rcc top slab 1:2:4 mix ( 1 cement: 2 coarse sand: 4 graded stone sggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement: 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design:with f.p.s. bricks , ex. phe 16 structual steel work welded in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. , ex. phe 17 making connection of gi distribution branch with gi main of 50 80mm nominal bore by providing and fixing tee, including cutting and threading the pipe etc. complete. , rain water harvesting 1 boring / drilling bore well of required dia for casing / strainer pipe, bysuitable method prescribed in is:2800 ( part i ) , including collecting sample from different strata , preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90m depth below ground level.300 mm dia , rain water harvesting 2 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150mm nominal size dia , rain water harvesting 3 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well screen ( rms ) pipes with ribs, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150 mm nominal size dia , rain water harvesting 4 supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 5 supplying, filling, spreading & levelling gravel of size range 5mm to 10mm, in recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 6 supplying, filling, spreading & levelling coarse sand of size range 1.5mm to 2mm, in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of engineer in charge. , rain water harvesting 7 providing and fixing bail plug / bottom plug of required dia to the bottom of pipe assembly of tube well as per is:2800 ( part i ) . 100 mm dia , rain water harvesting 8 making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and s.w. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , rain water harvesting 9 constructing soak pit 1.20x1.20x1.20 m filled with brickbats including s.w. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 , tubewell 1 boring / drilling bore well of required dia for casing / strainer pipe, bysuitable method prescribed in is:2800 ( part i ) , including collecting sample from different strata , preparing and submitting strata chart / bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of engineer in charge, upto 90m depth below ground level.300 mm dia , tubewell 2 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.150mm nominal size dia , tubewell 3 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well casing ( cm ) pipe of required dia, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.100mm nominal size dia , tubewell 4 supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized plc. medium well screen ( rms ) pipes with ribs, conforming to is: 12818, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per director of engineer in charge.100 mm nominal size dia , tubewell 5 supplying, filling, spreading & levelling stone boulders of size range 5cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of engineer in charge. , tubewell 6 providing and fixing bail plug / bottom plug of required dia to the bottom of pipe assembly of tube well as per is:2800 ( part i ) . 100 mm dia , submersible pump 35m deep boring with casing and pipe. supply of pipe etc supplying & installation of suitable 2hp submersible pump b.s or k.s.bor equivalent make with finolex cable 1x3x2.5 squmm ( upto 50mtr ) withflexible conduit 25mm dia, electrical out door pannel with required electrical fitting such as mcb of 0 25amp ( havell or indocopp or mds make ) , volt & ampere meter ( ae make ) , single phase preventer ( minilac or vsp 1 make ) starter ( l&t or bch make ) etc of approved make, 40mm hdpe pipe ( 25 mtr ) and all accessories complete as per requirement of site. , water purifier and cooler 1 fitting and fixing single faucet storage type water cooler ( size 461 mm wide x 582 mm deep x 1217 mm height, weight 46 kg ) fully stainless body having storage capacity of 40 ltrs, cooling capacity of 40 ltrs. / hr. with hermetic type compressor, gas cooled motor equipped with over load protector, condensor for propeller type, thermostat autometically controlled temperature, refrigerent r 22, 230 volt, single phase 50 hertz, maximum current 2.3 amp including plug top and electrical lead wire connection upto 3 metres from the cooler, water inlet and drain out connections complete in all respects of voltas model no 40 / 40 tushar pss type or similar type of approved make. , water purifier and cooler 2 fitting and fixing water purifier for drinking purpose of capacity 6 litres / min, 5 purification system with reverse osmosis system with ultra ventilated membrane, tds500 to 2000 mgl / ppm, auto shut off with microswitch float manual flush facility, tds reduction 90% having automatic backwash system with filteration unit along with all accessories including plug top and electrical lead wire connection upto 3 metres from the purifier, water inlet and drain out connections complete in all respects similar to aquaguard or similar approved make ( model aquasure elegant ro water purifier of size width 360 mm x height 430 mm x depth 235 mm and weight 8.5 kg ) . , fire extinguisher 1 providing and fixing carbon di oxide type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. capacity 4.5 kg. , fire extinguisher 2 providing and fixing abc powder type fire extinguishers consisting of welded m.s. cylindericalbody, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to is:15683 finished externally with red enamel paint and fixed to wall with brackets complete with internal charge.capacity 6.0 kg. , electrical 1 wiring for light point / fan point / exhaust fan point / call bellpoint with 1.5 sq.mm frls pvc insulated copper conductorsingle core cable in surface / recessed steel conduit, withmodular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm frls pvc insulated copper conductor single core cable etc. as required. group c , electrical 2 wiring for twin control light point with 1.5 sq.mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable gi box and earthing the point with 1.5 sq.mm. frls pvc insulated copper conductor single core cable etc. as required. , electrical 3 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulatedcopper conductor single core cable etc. as required. group c , pvc conduit 1 supplying and fixing of following sizes of medium class 20mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , pvc conduit 2 supplying and fixing of following sizes of medium class 32mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , pvc conduit 3 supplying and fixing of following sizes of medium class 50mmpvc conduit along with accessories in surface / recessincluding cutting the wall and making good the same incase of recessed conduit as required. , electrical 4 wiring for light / power plug with 2x4 sq. mm frls pvcinsulated copper conductor single core cable in surface / recessed steel conduit alongwith 1 no. 4 sq. mm frls pvcinsulated copper conductor single core cable for loop earthingas required. , wiring frls pvc insulated copper conductor 1 2 x 2.5 sq. mm. + 1 x 2.5 sq. mm. earth wire , wiring frls pvc insulated copper conductor 2 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire , wiring frls pvc insulated copper conductor 3 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire , wiring frls pvc insulated copper conductor 4 4 x 6 sq. mm + 2 x 6 sq. mm earth wire , wiring frls pvc insulated copper conductor 5 4 x 10 sq. mm + 2 x 6 sq. mm earth wire , wiring frls pvc insulated copper conductor 6 4 x 16 sq. mm + 2 x 16 sq. mm earth wire , s / f, gi box along with modular base & cover plate 1 1 or 2 module ( 75mm x 75mm ) , s / f, gi box along with modular base & cover plate 2 3 module ( 100mm x 75mm ) , s / f, gi box along with modular base & cover plate 3 4 module ( 125mmx75mm ) , s / f, gi box along with modular base & cover plate 4 6 module ( 200mm x 75mm ) , s / f, gi box along with modular base & cover plate 5 12 module ( 200mmx150mm ) , s / f modular switch / socket on the existing modular plate 1 5 / 6 amps switch , s / f modular switch / socket on the existing modular plate 2 15 / 16 amp switch , s / f modular switch / socket on the existing modular plate 3 3 pin 5 / 6 amp socket outlet , s / f modular switch / socket on the existing modular plate 4 6 pin 15 / 16 amp socket outlet , s / f modular switch / socket on the existing modular plate 5 telephone socket outlet , s / f modular switch / socket on the existing modular plate 6 tv antenna socket outlet , s / f modular switch / socket on the existing modular plate 7 bell push , fan regulator on the existing modular plate switch box supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. , call bell / buzze supplying and fixing call bell / buzzer suitable for single phase, 230 volts, complete as required. , electrical 5 supplying & fixing suitable size gi box wih modular plate and cover in front on surface or in recess including providing and fixing 25 a modular socket outlet and 25 a modular sp mcb, “c” curve including connections, painting etc. as required. ( for ac / geyser ) , electrical 6 supplying and drawing co axial tv cable rg 6 grade, 0.7 mm solid copper conductor pe insulated, shielded with fine tinned copper braid and protected with pvc sheath in the existing surface / recessed steel / pvc conduit as required. , electrical 7 supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. , electrical 8 providing and fixing m.s. fan clamp type i or ii of 16 mm dia m.s. bar, bent to shape with hooked ends in r.c.c. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. , electrical 9 providing and fixing circular / hexagonal cast iron or m.s. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick m.s. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron / m.s. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. clamp shall be made of 12 mm dia m.s. bar bent to shape as per standard drawing. , 40a fp isolator supplying and fixing following rating, four pole, 415 v, isolator in the existing mcb db complete with connections, testing andcommissioning etc. as required. , electrical 10 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. , electrical 11 supplying and fixing 20 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. , electrical 12 supplying and fixing 30 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 a c curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioningetc. as required. , electrical 17 supplying and fixing following way, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) 8 way ( 4 + 24 ) , double door , electrical 18 supplying and fixing of following ways surface / recess mounting, vertical type, 415 v, tpn mcb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 a tinned copper bus bar, common neutral link, earth bar, din bar for mounting mcbs ( but without mcbs and incomer ) as required . ( note : vertical type mcb tpdb is normally usedwhere 3 phase outlets are required. ) 4 way ( 4 + 12 ) , double door , electrical 19 supplying and fixing of following ways surface / recess mounting, vertical type, 415 v, tpn mcb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 a tinned copper bus bar, common neutral link, earth bar, din bar for mounting mcbs ( but without mcbs and incomer ) as required . ( note : vertical type mcb tpdb is normally usedwhere 3 phase outlets are required. ) 8 way ( 4 + 24 ) , double door , electrical 20 supplying and fixing cable end box ( loose wire box ) suitable for following triple pole and neutral, sheet steel, mcb distribution board, 415 volts, on surface / recess, complete with testing and commissioning etc.as required. for 8 way, double door fp mcbdb , electrical 21 supplying and fixing cable end box ( loose wire box ) suitable for triple pole and neutral, sheet steel, vertical mcb distribution board, 415 v, on surface / recess, complete with testing and commissioning etc. as required. , 25 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40 a, rccb supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. , single pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , triple pole mcb supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 40a tp mcb supplying and fixing 40 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40a tp mcb , 40a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. 40a fp mcb , 63a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , 100a 4p mcb supplying and fixing of following mcbs, 415 volts, c curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing mcb db complete with connections, testing and commissioning etc. as required. , l / f pvc sheathed / xlpe power cable in trench 1 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 95 sq. mm and upto 185 sq. mm , l / f pvc sheathed / xlpe power cable in trench 2 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. above 185 sq. mm and upto 400 sq. mm , l / f pvc sheathed / xlpe power cable over cable tray above 35 sq. mm and upto 95 sq. mm ( clamped with 25x3mm ms flat clamp ) , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 1 3.5c x 185 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 2 3.5c x 150 sqmm, aluminium conductor cable a2xfy , s / m end termination with brass compression gland and aluminium lugs aluminium conductor cable of 1.1 kv grade 3 4c x 35 sqmm aluminium conductor cable a2xfy , cable tray 1 supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 100 mm width x 50 mm depth x 1.6 mm thickness , cable tray 2 supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 300 mm width x 50 mm depth x 1.6 mm thickness , cable tray 3 supplying and installing following size of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required. 600 mm width x 62.5 mm depth x 2.0 mm thickness , cable tray “bends” 1 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.100 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 2 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.300 mm width x 50 mm depth x 1.6 mm thickness , cable tray “bends” 3 supplying and installing following size of perforated hot dipped galvanised iron cable tray “bends” ( galvanisation not less than 50 microns ) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with g.i. suspenders including g.i. bolts & nuts, etc. as required.600 mm width x 62.5 mm depth x 2.0 mm thickness , mv cable 1 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 185 sqmm, aluminium conductor cable a2xfy , mv cable 2 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required.3.5c x 150 sqmm, aluminium conductor cable a2xfy , mv cable 3 supplying following 1.1kv grade, xlpe insulated, frls type, heavy duty armoured cables suitable for 415v, 50hz, ac system, with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel armouring ( round ( w ) or flat ( f ) as mentioned ) and with all components as mentioned , specifications, complete as required. 4c x 35 sqmm aluminium conductor cable a2xfy , earthing 1 earthing with g.i. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. , earthing 2 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. , earthing 3 earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. , earthing 4 providing and fixing 6 swg dia g.i. wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. , earthing 5 providing and fixing 25 mm x 5 mm g.i. strip on surface or in recess for connections etc. as required. , earthing 6 providing and fixing 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required. , earthing 7 providing and fixing 25 mm x 5 mm g.i. strip in 40 mm dia g.i. pipe from earth electrode including connection with g.i. nut, bolt, spring, washer excavation and re filling etc. as required. , earthing 8 providing and fixing 25 mm x 5 mm copper strip in 40 mm dia g.i. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re filling etc. as required. , earthing 9 providing and fixing earth bus of 50 mm x 5 mm copper strip on surface for connections etc. as required. , earthing 10 providing and fixing earth bus of 50 mm x 5 mm gi strip on surface for connections etc. as required. , fiting & fixtures 1 supply and installation of regular / standard model a.c. ceiling fan of 1400 mm sweep including wiring the down rods of standard length ( upto 30 cm ) with 1.5 sq. mm fr pvc insulated copper conductor etc as required. , fiting & fixtures 2 supplying and fixing single wall mounted 18 / 22 watt led type batten fitting complete with electronic driver and led tube etc directly on wall / ceiling includingconnections with 1.5 sq.mm fr pvc insulated copper conductor and earthing the body etc. as required. , fiting & fixtures 3 supply installation and comissioning ofintegrated batten made ( 2ft ) of ultra slim co extruded polycarbonate channel with housing part in white finish & diffuser part in reeded opal finish.white finish abs end caps with decorative circular coloured polycarbonate cap snap fitted on the end cap to enhance the aesthetic of the fixture. these end caps are snap fitted to the fixture.high efficiency long life led with lumen efficacy of 130 lm / w with viewing angle of 120º.powered by an integral isolated low thd electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection.can be fixed directly into the wall / ceiling , fiting & fixtures 4 supplying and fixing recess mounted 12 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 5 supplying and fixing recess mounted 18 watt led vertical downlighter complete with all accessories and replaceable electronic driver, directly on false ceilingincluding connection with 1.5 sq.mm fr pvc insulated copper conductor cable and earthing the body etc. as required. , fiting & fixtures 6 supply, installation, testing and commissioning of 400 mm sweep, 65w, blade material aluminium blades , speed & oscillation 3 speed, pull cord for speed and oscillation.air delivery minimum 72 m³ / min, speed minimun 1350 revolution per minute.suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. , fiting & fixtures 7 supply installation and comissioning of 28w 2x2 panel recess mounting luminaire with high performance leds, suitable for mounting with armstrong / grid ceiling.crca powder coated white after phosphochromate treatment.high efficiency long life led package in integral module with lumen efficacy of >100 lm / w and viewing angle of 120° to ensure better uniformity.powered by an independent isolated, selv output electronic led driver ( smps based constant current supply ) with output short circuit protection, surge protection & other reliability test. , fiting & fixtures 8 supplying installation testing & commissioning ofb22 based 9w led 3 star bulb with 850 lumen, 6k color temperature including holder. , fiting & fixtures 9 supplying installation testing & commissioning of black painted extruded aluminium housing. green / red led’s mounted inside the housing. laser engraved signage matter on single / double acrylic sheet fixed on one side suitable for wall / ceiling / suspension type single / double sided display. in double sided version black paper is inserted. ni cd battery back up to 2 hrs. ( charged up to 8 10 hrs ) .mounting strings provided for pendent mounting operating voltage 150 280v ac ambient operating temperature. – 0 to 450c ingress protection – ip42.including 3 core 1.5 sq.mm frls pvc insulated and pvc sheathed copper conductor cable and earthing etc. up to suitable point complete as required.220208 besl 03 led ssd wbb green 240 3 8wor220209 besl 03 led ssd wbb red 240 3 8wor220210 besl 03 led dsd wbb green 240 3 8wor220211 besl 03 led dsd wbb red 240 3 8w , fiting & fixtures 10 supply, installation, testing and commissioning of 600 mm sweep, bee 5 star rated, ceiling fan with brush less direct current ( bldc ) motor, class of insulation: b, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value ( cmm / w ) minimum 6.85, air delivery minimum 135cmm, 350 rpm ( tolerance as per is : 374 2019 ) , thd less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c ( max. ) , insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac supply, earthing etc. complete as required. , civil & misc works1 providing and fixing m.v. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. , civil & misc works2 providing and fixing h.t. danger notice plate of 250 mm x 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. , civil & misc works3 supplying and making cable route marker with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm x 60 cm at the bottom and 50 cm x 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. , civil & misc works4 supplying and fixing cable route marker with 10 cm x 10 cm x 5 mm thick g.i. plate with inscription there on, bolted / welded to 35 mm x 35 mm x 6 mm angle iron, 60 cm long and fixing the same in ground as required. , civil & misc works5 providing & fixing in position 1000 mm wide , electrical insulating rubber mats as per is 15652:2006, 2 mm thick, suitable up to 1.1 kv , fire retardant, no effect of acids, alkalis and transformer oils, moisture proof, high tensile strengthandtexture finish / cloth impression ( anti slip , marking on top ) , civil & misc works6 supply & fixing shock treatment chart duly mounted on a wooden frame with 5 mm thick glass as required ( approx front area 1.20 sq metre ) , 20 kvaups supplying, installation, testing and commissioningof online double conversion fully microprocessor based , indoor type, compact ups system of following rating with igbt based pwm technology to achieve thd < 3% and input power factor of greater than 0.95 at 50% loading, suitable for three phase ac input voltage 380 v to 440 v, 50 hz +3% / 3 % and three phase ac output voltage 415 ± 1% volts & frequency 50 ± 0.5 hz , inbuilt isolation transformer, necessary vrla batteries of suitable size having 30 minutes back up time , mounting rack including and suitable size connecting cable ( for ups to battery and battery to battery ) , static and maintenance bypass switch, snmp card for rs232 / ethernet ip computability for operation and monitoring etc. with all components as mentioned , specifications, complete as required.note : concerning vendor needs to furnish the battery sizing calculations at the time of ga approval and battery size has to be as per the approved ga drawing. , external lighting 1 supply and erection of 4 metre height hot dip galvanized octagonal street light pole with following arm with top dia 70 mm and bottom dia a / f 130 mm, made of 3 mm thick sheet along with base plate of size 220 x 220 x 12 mm , small door opening for junction box mounting with mcb & connector, cement concrete of 1:3:6 including excavation, refilling and suitable size foundation bolts with template and all complete jobas required. ( but without pole collar ) single arm , external lighting 2 supplying and fixing 40 / 45 watt led type street light with die cast aluminium housing for ingress protection of ip65 and complete with all accessories etc, onpole / building including connection with fr pvc insulated copper conductor cable and earthing the body etc. as required. , transformer supplying, installation testing and commissioning of following rating, distribution transformer, suitable for 3 phase, 50hz, ac supply, dyn 11 vector group, core made of good quality crgo, windings made of double wound copper with approved danger and arc flash signages and with all components as mentioned , specifications and sld and complete as required. power rating 250 kva , 11 kv ht dp structure / ht cable 1 supplying 11kv ( earthed ) grade, xlpe insulated, heavy duty frls type, armoured cables suitable for 11kv, 50hz, ac system with inner and outer pvc sheath, outer sheath provided with frls insulation, galvanised steel flat armouring and with all components as mentioned in boq, specifications and sld, complete as required.3 core x 240 sq. mm , 11 kv ht dp structure / ht cable 2 supply, installation, testing and commissioning of 11 kv dp structure as per cei & hpseb norms & comprising of the following, but not limited to it for completion of worksfor the followingrsj pole of 9.15 mt length of size 175 x 90 mm complete with suitable m.s. base plate welded at bottombase plate 2 nos. , indoor cable end termination 2 supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, xlpe aluminium conductor cable of 11 kv grade as required. 300 sq. mm , outdoor cable end termination supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, xlpe aluminium conductor cable of 11 kv grade as required. 300 sq. mm , main lt panel main lt panel ( refer sld for detail ) supply, installation, testing and commissioning of indoor floor mounted / wall mounted, ip42 ( indoor ) and ip55 ( outdoor ) , factory built, modular, sectionalised, compartmentalized, extendable type lt cubicle panel of suitable size suitable for operation on 433 / 415 volts, 50 hz ac 3 phase 4 wire supply system fabricated from crca sheet steel of 2mm thick for , apfc panel apfc panel ( 200 kvar ) outoor type ( refer sld for detail ) , ip based cctv system 1 sitc of 2 megapixel @ 25fps, h.265 ip bullet camera, 1 / 2.9 cmos with 2.8~12mm varifocal lens, 0 lux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 2 sitc of 2 megapixel @ 25fps, h.265 ip dome camera, 1 / 2.9 cmos with 3.6 fixed mm 0 lux with night vision ir up to 30 mtrs.support intelligent analytics like abnormal video signal detection, video mask, heartbeat, password protection. supports digital wdr, icr, true d / n, 3d dnr, roi coding, poe, onvif, ip66 etc. complete as required. , cctv 4 sitc of 32ch 4k ivr , h.265 / h.264 • 1080p real time • 4k display • dual lan • 8x hdd • raid •web plugin free h.265 / h.264 compression technology 4k display for clear monitoring up to 1080p 16ch decoding ability smart search ii smart vca event searchsupport raid 0, 1, 5 supported to prevent from recording data loss browsers supported: ie , smart functions : target count, electric fence, face detection, humaniod detection, retrograde detection, leave position detectio output, local & network backup etc. complete as required. , cctv 5 sitc of harddiskdrive8tb, 24 / 7surveillance category only complete etc as required.etc.all complete , cctv 6 sitc of 55 led narrow bazel for monitoring for nvr server etc. all complete. , cctv 7 sitc of rj 45 outlets near the cameras etc. all complete. etc. all complete. , cctv 8 sitc of cat 6 patch cords 1 meter high quality four pair twisted stranded cable terminated with rj45 modular plugs at both the ends. , integrated it and epabx system sitcof cat 6 48 port jack panel for data as per given specification etc. all complete. , epabx system 2 sitcof cat 6 48 port jack panel for voice as per given specification etc. all complete. , epabx system 3 sitc of lszh cat 6 speed unshielded twisted pair computer cable with 23 awg solid copper conductors in existing concealed / surface conduits / raceways complete 305 mtr. roll as per specification etc. all complete. , epabx system 4 sitc of cat6 io, face plate, wall box combo2 port etc. all complete. , epabx system 5 sitcof cat 6 mounting cords 7 feet for data as per given specification etc. all complete. , epabx system 6 sitcof cat 6 patch cords 4 feet for telephone as per given specification etc. all complete. , epabx system 7 sitc of 24 port l2 managed 10 / 100 / 1000 mbps non poe switch with 4 sfp port , for data pointsrack mountable etc. all complete. , epabx system 8 sitc of 24 port l2 managed poe 10 / 100 / 1000 mbps switch with 4 sfp port , for cctv rack mountable etc. all complete. , epabx system 9 sitc of 24 port smart managed non poe with 4 sfp port rack mountable etc. all complete. , epabx system 10 sitc of 15 u mountingrack with ventilation, sliding shelves, power strips, etc. all complete. , epabx system 11 sitc of ip pbx for with 8 trunk 1 pri& 8 digital and 32 analog extension expendble upto 64 extesionsy etc all complete. , epabx system 12 25 pair riser cable , epabx system 13 mdf box25 pair with 20 pairkrone module , epabx system 14 supply, installation, testing & commissioning of analog phone with speaker , small display etc. all complete. , epabx system 15 client workstation supply, installation, testing & commissioning of client workstation as per following specifications:intel core i5 7700k, 4.2ghz, os genuine microsoft microsoft® windows 10 enterprise 64 bit, ram 16gb, memory 500 gbssd +1tb hdd 7200 rpm class graphic card in built processor graphics ( gpu ) :intel® hd graphics 630 and geforce gtx 970 4gb pcie x 16 lp supporting 2 / 4 monitors., two ( 2 ) pci express expansion slots 2 / 4 usb, 3.0 serial, and 2 hdmi / vga adaptor, cd / dvd rom.; usb keyboard and mouse, ups, associated cables etc. and other required software to control nvr in control room including centralized video management software as per the requirement of the successful operation of the surveillance system complete as required in accordance with laid specification or upto the satisfaction of engineer in charge. , signage 1 providing & fixing of building direction signage mounted on pole, with pole of 100x100mm shs ( square hollow section ) of height of 5600mm, and sign size of 900x1050, sign made of aluminiu c section of 60mm with internal framing to support the frame in ms tubes hollow section, frame work duly painted with anti rust coatings, with facia of 3mm thick exterior grade aluminium composite panel, cladded with uv cured digital printed retroreflective sheet of 3m make, and back panel of 3mm exterior grade acp, all pipes to be painted in approved color. cost shall includecost towards installation, including excuvation and filling up with specified pcc and fixing of foundation bolts as specified, also it shall include the designing charges.all complete as per direction by engineer in charge. , signage 2 providing & fixing of prohibition sign silk screen printed of approved colors, on acp of exterior grade, of size 300x300mm, all fixtures in stainless steel as per design, it shall include the designing charges .all complete as per direction by engineer in charge. , signage 3 providing & fixing traffic regulatory parking signage mounted on pole, with pole of 50x50mm shs ( square hollow section ) of height of 300mm, and sign size of 750x750, sign made of aluminium sheet of 3 mm thickness with aluminium supported profile to the frame of ms tube hollow section, aluminium sheet to be cladded with uv printed retroreflective sheet of 3m make frame work duly painted with anti rust coatings., all pipe to be painted in apppproved color. cost shall include cost towards installation, including excuvation and filling up with specified pcc and fixing of foundation bolts as specified, also it shall include the designing charges.all complete as per direction by engineer in charge. , signage 4 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge , wall projected 250x210mm, both sides , signage 5 providing and fixing of signages modular curved frame technology of various widths and lengths to fometre suggested usages made of aluminium extruded sections. duly anodised all signages shall be provided with 0.6 0.8mm polycarbonate protecting film over the prints of appropriate size .all complete as per direction by engineer in charge, door mounted, 300x80mm , 2 tr air conditioning 1 split ac ( inverter model ) : supply, installation, testing, commissioning of split type wall mounted air conditioning units of following capacity including inddor, outdoor unit fitted with inverter based rotary compressor fitted with rotary compressor, copper condensor and first charge refrigent r410a / eco friendly green gas only, all complete including all electrical connections to the electrical power supply system of the building, includingbut not limited to supply of all electrical plugs, etc., as necessary, lengthening of all electrical wires of ac units ( both indoor and outdoor ) , drain pipe andincluding suitable voltage stabilisers, etc. so as to place them in a concealed manner in the desired position. the copper pipes and electrical cables shall be concealed in approved manner and neatly run in straight lines in a workman like manner with proper supports. complete supply and installation of split2 tr star rating 3 star , refrigerant piping 1 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 25 mm od, wall thickness >= 1.2 mm ( insulation 19 mm thick ) , refrigerant piping 2 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 19.1 mm od, wall thickness >= 1.0 mm ( insulation 13 mm thick ) , refrigerant piping 3 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 15.9 mm od, wall thickness >= 0.8 mm ( insulation 13 mm thick ) , refrigerant piping 4 copper piping: supply, installation, providing, testing and commisioning of interconnectiong copper refrigent pipe work ( 19mm / 13 mm thick ) duly insulated with elastomeric nitrile rubber, joints shall be covered with nitrile tape of 3mm thick complete as per specification soft refrigerant copper piping as per specifications and drawings. 9.5 mm od, wall thickness >= 0.8 mm ( insulation 13 mm thick ) , drain piping 1 providing and fixing of cpvc 6 kg / cm2 drainpiping complete with fittings, supports, 6 mm thick closed cell elastomeric insulation as per specifications and drawings. 20 mm , drain piping 2 providing and fixing of cpvc 6 kg / cm2 drainpiping complete with fittings, supports, 6 mm thick closed cell elastomeric insulation as per specifications and drawings. 32 mm , main oxygen manifold supply, installation, testing and commissioning of following gas manifold system ( excluding cylinders ) . the manifold is configured for designed numbers of cylinders and is suitable to withstand a pressure of 145 kg / cm2, along withhigh pressure copper annealed tail pipes with end brass adapter suitable for cylinders and manifold. top frame comprising of high pressure copper pipes of size 1 / 2” nb x 15swg with high pressure brass fittings made of high tensile brass and connections through nonreturn valves, the design of middle and bottomframes is provided to fit both round and flat bottom cylinders safely. the manifold is tested ( hydraulically ) at 3500 psig. ( it should be ce and iso 13485 certified ) mani fold oxygen manifold 4 + 4 cylinder banks complete with nrv, middle frame, bottom frame with ce marked, , emergency manifold emergency oxygen manifold 01 + 01 cylinder emergency manifold with complete regulator, nrv, middle frame & bottom frame, , control panelfor oxygen fully automatic three port control panel for oxygen supply, installation, testing and commissioning of automatic manifold control panel would provide a duty or standby gas supply from two cylinder banks with automaticchangeover the manifold indicates local status and has a remote indicator facility. automaticmanifold control panel would be designed to supply the mgps with a constant pressure supply via a control panel form two equal banks of cylinders and the changeover from the , emergency manifold line regulator emergency manifold line regulator supply, installation, testing and commissioning of emergency manifold line regulator i n p u t p r e s s u r e 1 5 0 k g / c m 2 working pressure 4 kg / cm2 it should be ce and iso 13485 certified.oxygen input pressure 150 kg / cm2 working pressure 4 kg / cm2capacity : 1500 lpm , cylinderconnectingpipe ( pig tail ) supply, installation, testing and commissioning of cylinder connecting pipe ( pig tail ) made up of flexible ss hose with safety cord 5 / 8 inch bsp gland nut and one side 1 / 2 inch bsp internal threads having one meter length. ( oxygen 24 , n2o 10, co2 4 ) , backpressurecompensated [ bpc ] oxygen flowmeter supply, installation, testing and commissioning of back pressure compensated [ bpc ] oxygen flow meter body should be made of brass material dully chrome plated and graduated from 0 15 l / m on an expanded lower scale forprecision setting at low flow and 5 15 l / m for general use. the humidifier bottle should be made up of unbreakable polycarbonate / polysulphone material and autoclavable at 121 degree centigrade temperature. it should be ceand iso 13485 certified. , oxygen gas outletfront loadeddin / bsstd gas outlet front loaded din / bs std:supply, installation, testing and commissioning of din / british standard gas outlets are for use with medical gas system. the gas outlets completely complywith htm2002 and c11 standard regulations and pass the test of leakage and connector stability. medical gas outlet shall be gas specific for the services indicated and accept only corresponding din / british standard quickconnect adapter. specifically, gas specific indexed to eliminate interchangeability of gas services. the gas outlet is offered in consoletype, wall type with box and hose barb type gas system. it should be ce and iso 13485certified. din / bis std. gas outlets feature and benefits:* comply with htm2002 and c11 standardregulations* color coded according to iso32 color*100% pressure and leak tested* full range of mounting options* available in wall type with box, console typeand hose barb type* gas specific adapters , quickconnectadapter din / british standard quick connect oxygen adapter ( safety probe ) , tube oxygen h.p. rubber tube white color, , alarm supply, installation, testing and commissioningof area pressure alarm panel would be witdigital display, closed circuit, self monitoringtype. the alarm would be designed to monitorthe line pressure in piping systems.it should be ce and iso 13485 certified. withfour digit notified no. area line pressure alarm 1 gases , isolation valve, supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified.42mm , isolation valve 2 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 28mm , isolation valve 3 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 22mm , isolation valve 4 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 15mm , isolation valve 5 supply, installation, testing and commissioning of the ball valves [ for dividing the pipelines into various zones for the case of maintenance ] the internal ball with full borne is made of stainless steel with teflon seats. these valves are leakproof and needs only quarter turn for its operation [ either fully open or fully closed ] . it should be ce and iso 13485 certified 12mm , pipeline 1 medical grade copper pipeline ( in mtrs. ) as per en 13348, 12 mm ( od ) x 0.7 mm thickness , pipeline 2 medical grade copper pipeline ( in mtrs. ) as per en 13348, 15 mm ( od ) x 0.9 mm thickness , pipeline 3 medical grade copper pipeline ( in mtrs. ) as per en 13348, 22 mm ( od ) x 0.9 mm thickness , pipeline 4 medical grade copper pipeline ( in mtrs. ) as per en 13348, 28 mm ( od ) x 0.9 mm thickness , pipeline 5 medical grade copper pipeline ( in mtrs. ) as per en 13348, 42 mm ( od ) x 1.2 mm thickness , hospital sheet patient bedtype iii with mattress overall sizes: ( l ) 2268 mm x ( w ) 922 mm x ( h ) 610 mmdescription: sheet bed should be a plain bed used in the recovery ward.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crca , paediatric bed with mattress paediatric bed of overall sizes in mm: 1500 ( l ) x 850 ( w ) x 1210 ( h ) flat single section bed with grille frame on 4 sides.suitable for children up to 12 years.drop down grill frame on both sides for protection of the patient.material specifications: under structure has a higher diameter tubewhich should provide a sturdy understructure.lying surface area of crcafinish specifications: head board / leg board should be made of frame ms erw roundtube of sections ø19, ø25.4& ø31.75mm, ofthickness1.6 mmprovision for mounting of iv pole and mosquito net pole should be presentfinish specifications: powder coating should be bacteriostatic and thermosetting epoxy polyester, formulated to fulfill the requirements for bacterial protection.all powder coated parts in ral white , bed side locker type i over all dimension :402mmlx422mm wx840mm ht .locker should have one cabinet and one drawer unit .both provided with cam lock .there should be gap between drawer and unit to keep general items for frequesnt use castors are provided for easy handling .drawer made up of crca sheet 1 mm thick and has ball slide for easy operation .top ss 304 sheet 0.8 mm thick castors 50 mmdia , hamdle abs ..powder coating of epoxy polyester , medicinetrolleytype i overall size902mm ( l ) x532mm ( w ) x915mm ( h ) .top shelf should be made of ss 304 sheetof 1 mm thick. supporting legs made of ss304 tubesection 30.30 mm dia.of 1.2 mm thick provided to suppoort the entire structure.ss 304 tube provided at the bottom for placement of instument being used .handle made up of ss 304 tubeof dia dia 16 mmand thickness 1.2 mm provided to handle trolley .and maneuver accordingly. high endurance anti static plastic injection moulded castors of 125 mm dia.ss should be finished in glossy mirror finish. max load capacity of 10 kg / shelf udl , round stooltype i overall sizes diagonal legdia 538 mmh470 min 655max.ss 202 made sheet with spin section of thickness 1mm & should be non corrosive. it should have a diameter of 305mm, seat base is made of ms ring and rectangular tube.en8 screw having dia of 22 mm should be used for height adjustment of the seat base.the hub should be made of ms erw tube having dia of 38mm and thickness 2 mm.the hub should be welded with the legs and it should accommodate and cover the lead screw mechanism.the understructure should consist of 4 legs made up ofms erw tube of diameter 25.4 mm and 1.6mm thick. the press formed pipe leg should give a round & clean look. all the legs should be provided with 4 nos of nylon 6 bush.all metal componentsshould be pre treated with zinc phosphating in 9 tank process and then powder coated with anti microbialepoxy polyster powder coating . all welding should be co2 argon welding to minimise rusting on the welding areas.safe working load must be 135kg , strecher on trolley type i 2005mm ( l ) x666mm ( w ) x827mm ( h ) .the trolley should be made of 31.75 and 25.4 mm dia 1.6 mm thick erw tube.holder for stretcher should be made up of mild steel.castor should be of 200 mm dia , diagonal locking castor.stretcher should be made up oferw tubeof dia 25.4 mm and thickness 1.6 mm.top sheet should be made of crca sheetof thickness 1.2 mm with contour shape to accommodate patient.iv pole holder should be made ofms .maximum safe work load should be 135 kg.to ensure qood quality welding co2 argonprocess should be adhered to.all metal componentsshould be pre treated with zinc phosphating in 9 tank porcess and then powder coated with anti microbialepoxy polyster powder coating.goods should be supplied in knocked down construction to reduce carbon emission. performance test :proof loading test , cycle tests , impact test, salt spray test, castor break test, the manufacturer should compilant with iso 9001, 14001, 13485, ohsas 1800 and ce certification. , doctor desk type x s / f / f executive table main desk should be of dimesion : 1350w x 750d x 750h.the table top should bein white cedar, side panelsin black, while the modestypanel ina combination of black & white cedar. side panels : ( black ) made form 18mm thick plt with pvc lipping.modesty panel : made form 18mm thick plt with pvc lipping. bigger upper panel in black and smaller lower panel in white cedar. made from 18mm thick plt with pvc lipping. mobile pedestal : one box and one filing drawer with 18mm thick plb fronts and top. handles : black powder coated die cast aluminum alloy handles. mobile pedestal and hdu are fitted with central lock. , chair type iii s / f / f executive chair1 ) seat / back assembly: the seat and back are made up of 1.2 cm. thick hot pressed plywood, upholstered withfabric upholstery covers and moulded polyurethane foam. the back foam is designed with contoured lumbar support for extra comfort. the seat has extra thick foam on front edge to give comfort to popliteal area.high back size : 47.5 cm ( w ) x 69.5 cm ( h ) seat size : 47.0 cm. ( w ) x 48.0 cm. ( d ) 2 ) polyurethane foam: the polyurethane foam is moulded with density = 45 + / 2 kg / m 3and hardness = 20 + / 2at 25% compression. 3 ) armrests: the one piece armrests are injection moulded from black co polymer polypropylene. 4 ) center tilt synchro mechanism : the mechanism is designed with the following features:· 360 revolving type. · upright position locking. · tilt tension adjustment.· seat / back tilting ratio of 1:3 ( 60 seat tilt / 180 back tilt ) . 5 ) pneumatic height adjustment : the pneumatic height adjustment has anadjustment stroke of 12.0 cm. 6 ) telescopic bellow assembly : the bellow is 3 piece telescopic type and injection moulded in black polypropylene. 7 ) pedestal assembly : the pedestal is injection moulded in black 30% glass filled nylonand fitted with 5 nos. twin wheel castors. the pedestal is 66.0cm pitch center dia. ( 76.0 cm with castors. ) 8 ) twin wheel castors : the twin wheel castors are injection moulded in black nylon. , staff chair type i chair of over all size: 58.0cm ( w ) x 56.5cm ( d ) x 87.5cm ( h ) & 48.0cm ( sh ) seat / back assembly: the seat and back are made from chemically treated and seasoned wood, upholstered with plywood, black leather cloth, and u foam.*back size: 46.0cm ( w ) x 27.0cm ( h ) .*seat size: 46.0cm ( w ) x 40.0cm ( d ) .armrest tube: the armrest tube is made of m.s. e.r.w. tube dia. 2.54cm. ( 1” ) x 16bg thick and powder coated.armrest: the armrest is gas assisted injection moulded from black polypropylene.understructure assembly: the understructure assembly is a cantilever type frame made of dia. 2.54cm. ( 1” ) x 14bg. thick m.s. e.r.w. tube and powder coated. , visiter chair type v s / f / f visitor chair1 ) seat / back assembly: the seat and back are made up of 1.2 cm. thick hot pressed plywood, upholstered with fabric upholstery covers and moulded polyurethane foam. the back foam is designed with contoured lumbar support for extra comfort. the seat has extra thick foam on front edge to give comfort to popliteal area. mid back size : 47.5 cm. ( w ) x 58.0cm. ( h ) seat size : 47.0 cm. ( w ) x 48.0 cm. ( d ) 2 ) polyurethane foam: the polyurethane foam is moulded with density = 45 + / 2 kg / m 3and hardness = 20 + / 2at 25% compression. 3 ) armrests: the one piece armrests are injection moulded from black co polymer polypropylene. 4 ) tubular frame : the powder coated tubular frame is cantilever type & made of dia 25.4mm x 2mm thk m.s. er.w. tube. , wheel chair type i ( l ) 790 x ( w ) 600 x ( h ) 870mm.foldable frame structure should be made of section 22diax1.2mm a3 carbon steel with chrome finish. cross bar should be made of a3 carbon steel with section 25.4 x 1.2mm.rear wheel:24 inch solid mag wheels with alloy in the rim .integrated handrim provide to drive the wheel chair of section 16x1.2mm a3 carbon steel with chrome finish.front wheel :8 inch hub made of pa polymer and outer with solid rubber.pu molded arm rest & base should be made of abs for better arm support .leatherite strap for calf rest & leatherite cushion for seat.adjustable alluminimum die cast foot rest with updown & swivel type mechanism.handles should be made of moulded rubber grip to push the wheelchair.hand brakes should be provided to lock the wheelchair at desired location.foot pressextended base with molded plastic for better grip.anti rust chrome finsh. safe work load of100 kg , basin stand type i ht 850 mm ss bowl ms tubular frame of dia 25.4 x1.2 mm tube work mounted on three 50 dia.non rusting castors all without brack. ss part finished with matt polish , kick buckettype i overa all dimension of the bucket should be 517 mm ( l ) x 517 mm ( w ) x 210 mm h.it should made of 12.7 mm dia and 1.6 mm thick ss 304 ring. the bowl should be ss made of .8 mm thck .3 nos 50 mm diahigh endurance plasticinjection moulded castors should be provided for the movement.mx load bearing capacity should be 10 kg. , instrument cabinet type i overall dimensions of 900mmwx 1990mmhx450mmd and should have transparent doors and sides with steel frame work. transparent portion of this cupboard should be made of acrylic of 4mm thick. this cabinet should have 5 adjustable acrylic shelves each of 6 mm thickness. three way lock should be provided of 6 levers. in the front door there should be 4 acrylic sheets and 2 each on both the sides. metal used should be of crca and powder coated for finish. to be provided with rubber shoes to prevent direct contact of cabinet and floor. , hospital curtain tracks & i.v. tree system supply installation testing & commissioning of cubical tracks system made of powder coated aluminium alloy, stain free polyster fabric , water repellent curtains , smooth movement , non sticking runnner with stainless steel hooks made from mirror finish stainless steel , adjustable height with all accessories. total quantity : 1...